ATTACHMENT 7 DRAWINGS 145 AW Repair Maint. Hangar Building 51 dated 20 July 2022 Vol 3.pdf

PDF 17 MB Posted

Attached to
Repair Building 51
Solicitation number
W50S87-23-B-0001
Issued by

View the file

Other files

File Type Posted
Bid Opening Sign-in Sheet.jpg JPG image
OF 1419 Abstract signed.pdf PDF
Questions and Answers 07102023.pdf PDF
Amendment 0001.pdf PDF
Pre-bid signin sheet.jpg JPG image
PreBidSlides_W50S87-23-B-0001 Repair Building 51.pptx PPTX presentation
Pre Bid Sign in sheet.jpg JPG image
ATTACHMENT 13 BRAND NAME JUSTIFICATION Monaco Fire Alarm Trasceiver redacted.pdf PDF
ATTACHMENT 1 SPECS REPAIR BUILDING 51 FJRP112701 dated 20 July 2022 Vol 1 of 4 502 pages.pdf PDF
ATTACHMENT 12 BRAND NAME JUSTIFICATION Interior and Exterior Finishes redacted.pdf PDF
ATTACHMENT 18 145 AW CONTRACTOR SECURITY GUIDE.pdf PDF
ATTACHMENT 5 DRAWINGS 145 AW Repair Maint. Hangar Building 51 dated 20 July 2022 Vol 1.pdf PDF
ATTACHMENT 16 PREBID CONFERENCE SITE VISIT and BID DROP OFF MAP.pdf PDF
W50S87-23-B-0001.pdf PDF
ATTACHMENT 19 145 AW CONTRACTOR ENVIRONMENTAL GUIDE.pdf PDF
ATTACHMENT 17 145 AW CONTRACTOR SAFETY GUIDE.pdf PDF
ATTACHMENT 9 SOW Repair Bldg 51 dated 6 November 2022.pdf PDF
ATTACHMENT 8 DRAWINGS 145 AW Repair Maint. Hangar Building 51 dated 20 July 2022 Vol 4.pdf PDF
ATTACHMENT 3 SPECS REPAIR BUILDING 51 FJRP112701 dated 20 July 2022 Vol 3 of 4 490 pages.pdf PDF
ATTACHMENT 15 VISITOR REQUEST WORKSHEET.pdf PDF
ATTACHMENT 4 SPECS REPAIR BUILDING 51 FJRP112701 dated 20 July 2022 Vol 4 of 4 444 pages.pdf PDF
ATTACHMENT 11 BRAND NAME JUSTIFICATION Alerton Direct Digital Controls redacted.pdf PDF
ATTACHMENT 6 DRAWINGS 145 AW Repair Maint. Hangar Building 51 dated 20 July 2022 Vol 2.pdf PDF
ATTACHMENT 10 BRAND NAME JUSTIFICATION - Best Door hardware redacted.pdf PDF
ATTACHMENT 14 BRAND NAME JUSTIFICATION- Sika Sarnafil PVC Roof Membrane redacted.pdf PDF
ATTACHMENT 2 SPECS REPAIR BUILDING 51 FJRP112701 dated 20 July 2022 Vol 2 of 4 542 pages.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT MAP:

PROJECT

LOCATION

BASE

ENTRANCE

CONSTRUCTION

ENTRANCE

BASE

OUTLINE

STATE MAP:

STATE OF NORTH CAROLINA

CITY OF CHARLOTTE,

MECKLENBURG COUNTY

VICINITY MAP:

PROJECT LOCATION

1. ROLLER SHADES IN LEU OF SLAT BLINDS

2. EPOXY FLOOR IN ROOMS:

A. HYDRO SHOP

B. WHEEL/TIRE SHOP

C. SUPPORT EQUIPMENT

D. CTK

3. ADDITIONAL PARKING SPACES

BID OPTIONS:

ANG PROJECT No.:

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281

/1

/2

:3 :5

P

M C

R e v it L o c a l\

.0

-A -R c h ri s .d o u g a n

.r v t

FJRP112701

REPAIR MAINTENANCE HANGAR BUILDING 51

CHARLOTTE DOUGLAS IAP

CHARLOTTE, NORTH CAROLINA

NCANG - 145TH AW

COVER SHEET -

VOLUME 3

FJRP112701ANG PRO. NO.:

3258000-181469.01

NJD, KB

DMD

July 20, 2022

ATM

N C

A N

G

T

H A

W

C H

A R

L O

T T

E D

O U

G L A

S I A

P C

H A

R L O

T T

E N

O R

T H

C A

R O

L

IN

A

R E

P A

IR

M

A

IN

T E

N A

N C

E H

A N

G A

R B

U

IL

D

IN

G

G-000C

VOLUME 3

07/20/22 B-3 SUBMITTAL

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

ISSUED

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281

/2

/2

:0

:2

A

M C

R e v it L o c a l\

.0

-A -R c h ri s .d o u g a n

.r v t

SHEET INDEX -

VOLUME 3

FJRP112701ANG PRO. NO.:

3258000-181469.01

NJD, KB

DMD

July 20, 2022

ATM

N C

A N

G

T

H A

W

C H

A R

L O

T T

E D

O U

G L A

S I A

P C

H A

R L O

T T

E N

O R

T H

C A

R O

L

IN

A

R E

P A

IR

M

A

IN

T E

N A

N C

E H

A N

G A

R B

U

IL

D

IN

G

G-001C

SHEET INDEX - VOLUME 2

A-515 PLAN DETAILS INTERIOR - MINOR CONSTRUCTION

A-601 DOOR AND FRAME SCHEDULES AND LEGENDS - EXIST & AREA A

A-602 DOOR AND FRAME SCHEDULES AND LEGENDS - AREAS B & C

A-603 WINDOW TYPES & DETAILS

A-605 TRANSLUCENT PANEL DETAILS

A-621 DOOR DETAILS-INTERIOR AND EXTERIOR

A-700 FINISH SCHEDULES

A-701A FINISH PLAN - AREA A

A-701A2 FINISH PLANS - AREA A2

A-701B FINISH PLAN - AREA B

A-701B2 FINISH PLAN - MINOR CONSTRUCTION AREA B2

A-701C FINISH PLAN-AREA C

A-702A HANGAR BAY STRIPING PLAN

A-703 FINISH DETAILS

A-801A SIGNAGE PLAN - AREA A

A-801A2 SIGNAGE PLANS - AREA A2

A-801B SIGNAGE PLAN - AREA B

A-801B2 SIGNAGE PLAN - MINOR CONSTRUCTION AREA B2

A-801C SIGNAGE PLAN - AREA C

A-804 SIGNAGE PLAN - LOWER CATWALK

A-805 SIGNAGE PLAN - UPPER CATWALK

A-851 SIGNAGE DETAILS

A-852 SIGNAGE SCHEDULE

A-901A2 FIXTURES, FURNITURE AND EQUIPMENT PLANS - AREA A2

A-901B FIXTURES, FURNITURE AND EQUIPMENT PLAN - AREA B

A-901C FIXTURES, FURNITURE AND EQUIPMENT PLAN - AREA C

Sheets in Volume: 135

SHEET INDEX - VOLUME 2

GENERAL

G-001B SHEET INDEX - VOLUME 2

ARCHITECTURAL

A-001 NOTES & SYMBOLS

A-002 PARTITION TYPES

A-003 PARTITION DETAILS & TOILET ACCESSORY MOUNTING HEIGHTS

A-004 ASSEMBLIES

A-005 ARCHITECTURAL KEYNOTES

AD100 DEMOLITION OVERALL PLAN

AD101A DEMOLITION FLOOR PLAN - AREA A

AD101B DEMOLITION FLOOR PLAN - AREA B

AD101C DEMOLITION FLOOR PLAN - AREA C

AD101C2 DEMOLITION FLOOR PLAN - MINOR CONSTRUCTION AREA C2

AD102A DEMOLITION MEZZANINE PLAN - AREA A

AD102A2 DEMOLITION MEZZANINE PLANS - AREA A2

AD105A DEMOLITION ROOF PLAN - AREA A

AD105B DEMOLITION ROOF PLAN - AREA B

AD105C DEMOLITION ROOF PLAN - AREA C

AD105C2 DEMOLITION ROOF PLAN - MINOR CONSTRUCTION AREA C2

AD121A DEMOLITION REFLECTED CEILING PLAN - AREA A

AD121B DEMOLITION REFLECTED CEILING PLAN - AREA B

AD121C DEMOLITION REFLECTED CEILING PLAN - AREA C

AD201 DEMOLITION EXTERIOR ELEVATIONS - AREA A

AD202 DEMOLITION EXTERIOR ELEVATIONS - AREA A

AD203 DEMOLITION EXTERIOR ELEVATIONS - AREA B

AD204 DEMOLITION EXTERIOR ELEVATIONS AREA C

AD205 DEMOLITION EXTERIOR ELEVATIONS - MINOR CONSTRUCTION

AD206 DEMOLITION EXTERIOR ELEVATIONS - AREA C2

AD301 DEMOLITION SECTIONS

A-100 OVERALL PLAN

A-101A FIRST FLOOR PLAN - AREA A

A-101A2 FIRST FLOOR PLANS - AREA A2

A-101B FIRST FLOOR PLAN - AREA B

A-101B2 FIRST FLOOR PLAN - MINOR CONSTRUCTION AREA B2

A-101C FIRST FLOOR PLAN - AREA C

A-101C2 FIRST FLOOR PLAN - MINOR CONSTRUCTION AREA C2

A-102 MEZZANINE PLAN - OVERALL

A-102A2 MEZZANINE PLANS - AREA A2

A-102A3 MEZZANINE ISOMETRICS - AREA A2

A-102B2 CLERESTORY FLOOR PLAN - MINOR CONSTRUCTION AREA B2

A-103 LOWER CATWALK PLAN

A-104 UPPER CATWALK PLAN

A-105 ROOF PLAN - OVERALL

A-105A ROOF PLAN - AREA A

A-105B ROOF PLAN - AREA B

A-105B2 ROOF PLAN - MINOR CONSTRUCTION AREA B2

A-105C ROOF PLAN - AREA C

A-105C2 ROOF PLAN - MINOR CONSTRUCTION AREA C2

A-121A REFLECTED CEILING PLAN - AREA A

A-121A2 REFLECTED CEILING PLANS - AREA A2

A-121B REFLECTED CEILING PLAN - AREA B

A-121B2 REFLECTED CEILING PLAN - MINOR CONSTRUCTION AREA B2

A-121C REFLECTED CEILING PLAN - AREA C

A-121C2 REFLECTED CEILING PLAN - MINOR CONSTRUCTION AREA C2

A-122B ENLARGED CEILING PLANS - AREAS B & C

A-151A2 FIRST FLOOR AIR BARRIER PLANS - AREA A2

A-151B FIRST FLOOR AIR BARRIER PLAN - AREA B

A-151B2 FIRST FLOOR AIR BARRIER PLAN - MINOR CONSTRUCTION AREA B2

A-151C FIRST FLOOR AIR BARRIER PLAN - AREA C

A-152B2 CLERESTORY AIR BARRIER PLAN - MINOR CONSTRUCTION AREA B2

A-152C2 CLERESTORY AIR BARRIER PLAN - MINOR CONSTRUCTION AREA C2

A-201 EXTERIOR ELEVATIONS - AREA A

A-202 EXTERIOR ELEVATIONS - AREA A

A-203 EXTERIOR ELEVATIONS - AREA B

A-204 EXTERIOR ELEVATIONS - MINOR CONSTRUCTION AREA B2

A-205 EXTERIOR ELEVATIONS - AREA C

A-206 EXTERIOR ELEVATIONS - MINOR CONSTRUCTION AREA C2

A-207 EXTERIOR FACADE REPAIR ELEVATIONS - AREA A

A-208 EXTERIOR FACADE REPAIR ELEVATIONS - AREAS B & C

A-301 BUILDING SECTIONS - AREA A

A-302 BUILDING SECTIONS - AREA A2

A-303 BUILDING SECTIONS - AREA B

A-304 BUILDING SECTIONS - MINOR CONSTRUCTION AREA B2

A-305 BUILDING SECTIONS - MINOR CONSTRUCTION AREA C2

A-310 WALL SECTIONS - AREA A

A-311 WALL SECTIONS - AREA A2 SOUTH HANGAR SHOP

A-312 WALL SECTIONS - AREA A2 NORTH HANGAR SHOP

A-313 WALL SECTIONS - AREA B

A-314 WALL SECTIONS - AREA B

A-315 WALL SECTIONS - MINOR CONSTRUCTION AREA B2

A-316 WALL SECTIONS - AREAS B & B2

A-317 WALL SECTIONS - MINOR CONSTRUCTION AREA B2

A-318 WALL SECTIONS - AREAS B & C

A-319 WALL SECTIONS - AREA C

A-320 WALL SECTIONS - MINOR CONSTRUCTION AREA C2

A-321 WALL SECTIONS - AREA B & C AIR BARRIER

A-322 WALL SECTIONS - HANGAR SHOP AIR BARRIERS

A-400 ENLARGED PLANS AND INTERIOR ELEVATIONS - AREA A

A-401 INTERIOR ELEVATIONS - AREA A

A-402 ENLARGED PLANS AND INTERIOR ELEVATIONS - AREA B

A-403 ENLARGED PLANS AND INTERIOR ELEVATIONS - AREA B

A-404 ENLARGED PLANS AND INTERIOR ELEVATIONS - AREA C

A-405 INTERIOR ELEVATIONS - AREA C

A-406 CASEWORK DETAILS

A-410 RAILING TYPES

A-411 ENLARGED STAIR AND SHIPS LADDER PLANS & SECTIONS - AREA B, B2 &

HANGAR SHOP SOUTH

A-412 ENLARGED STAIR AND SHIPS LADDER PLANS & SECTIONS - HANGAR SHOP

NORTH

A-501 ROOF DETAILS

A-502 SECTION DETAILS EXTERIOR

A-503 SECTION DETAILS - AREA A

A-504 SECTION DETAILS EXTERIOR - MINOR CONSTRUCTION AREA B2

A-505 SECTION DETAILS EXTERIOR - MINOR CONSTRUCTION AREA B2

A-506 SECTION DETAILS - MINOR CONSTRUCTION AREA C2

A-507 SECTION DETAILS - MINOR CONSTRUCTION AREA C2

A-508 SECTION DETAILS - INTERIOR

A-509 PLAN DETAILS - AIR BARRIER

A-510 SECTION DETAILS - AIR BARRIER

A-511 PLAN DETAILS EXTERIOR - MINOR CONSTRUCTION AREAS B & B2

A-512 PLAN DETAILS - MINOR CONSTRUCTION AREA B2

A-513 PLAN DETAILS EXTERIOR - MINOR CONSTRUCTION AREA C2

A-514 PLAN DETAILS INTERIOR - AREAS A, B & C

SHEET INDEX - VOLUME 1

GENERAL

G-001A SHEET INDEX - VOLUME 1

G-003 CODE ANALYSIS

G-004A ROOM OCCUPANCY CLASSIFICATIONS

G-004B OCCUPANCY PLANS

G-005A LIFE SAFETY PLAN - AREA A

G-005A2 LIFE SAFETY PLANS - AREA A2

G-005B LIFE SAFETY PLANS - AREA B & C

G-006A LIFE SAFETY PLAN - LOW CATWALK

G-007A LIFE SAFETY PLAN - UPPER CATWALK

CIVIL

C100 CIVIL LEGEND AND ABBREVIATIONS

VF101 EXISTING CONDITIONS

GC121 SURVEY CONTROL PLAN

GC141 CONSTRUCTION ACCESS & LOCATION PLAN

GC145 CONSTRUCTION OPERATION PLAN NOTES

BB101 PLAN & LOG OF SOIL BORINGS

EC101 EROSION CONTROL PLAN

EC501 EROSION CONTROL DETAILS

CD101 DEMOLITION PLAN

CS111 SITE PLAN

CS121 ENLARGED SITE AND PAVING PLAN - AREAS 1 & 2

CS122 ENLARGED SITE AND PAVING PLAN - AREA 3

CS501 SITE DETAILS

CS502 SITE DETAILS

CS503 SITE DETAILS

CS504 SITE DETAILS

CG121 ENLARGED GRADING & DRAINAGE PLAN - AREAS 1 & 2

CG122 ENLARGED GRADING & DRAINAGE PLAN - AREA 3

CU101 ENLARED UTILITY PLAN - AREA 3

CU501 UTILITY DETAILS

CU502 UTILITY DETAILS

STRUCTURAL

S-001 NOTES, SYMBOLS, AND ABBREVIATIONS

S-002 NOTES, SYMBOLS, AND ABBREVIATIONS

S-005 STATEMENT OF SPECIAL INSPECTIONS

S-006 STRUCTURAL STEEL SPECIAL INSPECTIONS

S-007 MASONRY AND STEEL DECK SPECIAL INSPECTIONS

S-008 STRUCTURAL PROJECT KEYNOTES

S-010 ROOF LOADING PLAN

S-052A EXISTING BOTTOM CHORD FRAMING PLAN - AREA A

S-053A EXISTING ROOF FRAMING PLAN - AREA A

SD101A FOUNDATION AND FLATWORK DEMOLITION PLAN - AREA A

SD101B FOUNDATION AND FLATWORK DEMOLITION PLAN - AREA B

SD101C FOUNDATION AND FLATWORK DEMOLITION PLAN - AREA C

SD101C2 FOUNDATION AND FLATWORK DEMOLITION PLAN - MINOR

CONSTRUCTION - AREA C2

SD131B STRUCTURAL DEMOLITION FLOOR PLAN - AREA B

SD131C STRUCTURAL DEMOLITION FLOOR PLAN - AREA C

SD152A BOTTOM CHORD FRAMING DEMOLITION PLAN - AREA A

S-101A FOUNDATION PLAN - AREA A

S-101A2 FOUNDATION PLANS - AREA A2

S-101B FOUNDATION PLAN - AREA B

S-101B2 FOUNDATION PLAN - MINOR CONSTRUCTION - AREA B2

S-101C FOUNDATION PLAN - AREA C

S-101C2 FOUNDATION PLAN - MINOR CONSTRUCTION - AREA C2

S-111A FLATWORK PLAN - AREA A

S-111A2 FLATWORK PLANS - AREA A2

S-111B FLATWORK PLAN - AREA B

S-111B2 FLATWORK PLAN - MINOR CONSTRUCTION - AREA B2

S-111C FLATWORK PLAN - AREA C

S-111C2 FLATWORK PLAN - MINOR CONSTRUCTION - AREA C2

S-131A STRUCTURAL FLOOR PLAN - AREA A

S-131A2 STRUCTURAL FLOOR PLANS - AREA A2

S-131B STRUCTURAL FLOOR PLAN - AREA B

S-131B2 STRUCTURAL FLOOR PLAN - MINOR CONSTRUCTION - AREA

B2

S-131C STRUCTURAL FLOOR PLAN - AREA C

S-142A MEZZANINE FRAMING PLAN - AREA A

S-142A2 MEZZANINE FRAMING PLANS - AREA A2

S-151B ROOF FRAMING PLAN - AREA B

S-151C ROOF FRAMING PLAN - AREA C

S-151C2 ROOF FRAMING PLAN - MINOR CONSTRUCTION - AREA C2

S-152A BOTTOM CHORD FRAMING PLAN - AREA A

S-153A ROOF FRAMING PLAN - AREA A

S-153B2 HIGH ROOF FRAMING PLAN - MINOR CONSTRUCTION - AREA

B2

S-153C2 HIGH ROOF FRAMING PLAN - MINOR CONSTRUCTION - AREA

C2

S-301 SECTIONS

S-411 ENLARGED FLATWORK PLANS

S-431 ENLARGED STRUCTURAL FLOOR PLANS

S-441 ENLARGED FRAMING PLAN AND DETAILS

S-501 FOUNDATION DETAILS

S-502 FOUNDATION DETAILS

S-511 FLATWORK DETAILS

S-512 FLATWORK DETAILS

S-521 WALL DETAILS

S-522 WALL DETAILS

S-541 FRAMING DETAILS

S-542 FRAMING DETAILS

S-543 FRAMING DETAILS

S-544 FRAMING DETAILS

S-545 FRAMING DETAILS

S-551 FRAMING DETAILS

S-552 FRAMING DETAILS

S-601 STRUCTURAL SCHEDULES

Sheets in Volume: 90

SHEET INDEX - VOLUME 3

GENERAL

G-001C SHEET INDEX - VOLUME 3

FIRE ALARM

FA001 NOTES & SYMBOLS

FAD101 FIRE ALARM OVERALL DEMO PLAN

FA102 FIRE ALARM AND MNS FLOOR PLAN HANGAR

FA103 FIRE ALARM AND MNS FLOOR PLAN NORTH WING

FA104 FIRE ALARM AND MNS ENLARGED FLOOR PLAN EAST WING

FA105 FIRE ALARM AND MNS RISER DIAGRAM AND MATRIX

FIRE PROTECTION

FX001 NOTES & SYMBOLS

FXD101 FIRE PROTECTION HANGAR DEMO PLAN

FXD102 FIRE PROTECTION DEMO PLAN NORTH WING

FX101 DESIGN DENSITY PLAN HANGAR

FX102 DESIGN DENSITY NORTH WING

FX102B2 DESIGN DENSITY PLAN - AREA B2 - MINOR CONSTRUCTION

FX103 FIRE PROTECTION HANGAR FLOOR PLAN

FX104 FIRE PROTECTION FIRE PUMP ROOM

FX105 FIRE PROTECTION SPRINKLER ROOM

PLUMBING

P-001 PLUMBING NOTES & SYMBOLS

PD100B UNDERGROUND DRAIN AND VENT DEMO PLUMBING PLAN - AREA B

PD100C UNDERGROUND DRAIN AND VENT DEMO PLUMBING PLAN - AREA C

PD101A ABOVEGROUD DRAIN AND VENT DEMO PLUMBING PLAN - AREA A

PD101B ABOVEGROUND DRAIN AND VENT DEMO PLUMBING PLAN - AREA B

PD101C ABOVEGROUND DRAIN AND VENT DEMO PLUMBING PLAN - AREA C

PD102A ROOF - DRAIN AND VENT DEMO PLUMBING PLAN - AREA A

PD102B ROOF - DRAIN AND VENT DEMO PLUMBING PLAN - AREA B

PD102C ROOF - DRAIN AND VENT DEMO PLUMBING PLAN - AREA C

PD131A SUPPLY DEMO PLUMBING PLAN - AREA A

PD131B SUPPLY DEMO PLUMBING PLAN - AREA B

PD131C SUPPLY DEMO PLUMBING PLAN - AREA C

P-100A2 UNDERGROUND DRAIN AND VENT PLUMBING PLAN - HANGAR SHOPS

P-100B UNDERGROUND DRAIN AND VENT PLUMBING PLAN - AREA B

P-100B2 UNDERGROUND DRAIN AND VENT PLUMBING PLAN - AREA B2

P-100C UNDERGROUND DRAIN AND VENT PLUMBING PLAN - AREA C

P-101A DRAIN AND VENT PLUMBING PLAN - AREA A

P-101A2 DRAIN AND VENT PLUMBING PLAN - HANGAR SHOPS

P-101B DRAIN AND VENT PLUMBING PLAN - AREA B

P-101B2 DRAIN AND VENT PLUMBING PLAN - AREA B2

P-101C DRAIN AND VENT PLUMBING PLAN - AREA C

P-102A ROOF - DRAIN AND VENT PLUMBING PLAN - AREA A

P-102B ROOF - DRAIN AND VENT PLUMBING PLAN - AREA B

P-102B2 ROOF - DRAIN AND VENT PLUMBING PLAN - AREA B2

P-102C ROOF - DRAIN AND VENT PLUMBING PLAN - AREA C

P-131A SUPPLY PLUMBING PLAN - AREA A

P-131A2 SUPPLY PLUMBING PLANS - HANGAR SHOPS

P-131B SUPPLY PLUMBING PLAN - AREA B

P-131C SUPPLY PLUMBING PLAN - AREA C

P-501 PLUMBING DETAILS

P-502 PLUMBING DETAILS

P-601 PLUMBING SCHEDULES

P-602 PLUMBING SCHEDULES

P-901 DRAIN AND VENT ISOMETRIC PLUMBING DIAGRAM

P-931 SUPPLY ISOMETRIC PLUMBING PLAN

MECHANICAL

M-001 MECHANICAL NOTES & SYMBOLS

MD101A HVAC DEMOLITION FLOOR PLAN - AREA A

MD101B HVAC DEMOLITION FLOOR PLAN - AREA B

MD101C HVAC DEMOLITION FLOOR AND ROOF PLAN - AREA C

MD105A HVAC DEMOLITION ROOF PLAN - AREA A

MD105B HVAC DEMOLITION ROOF PLAN - AREA B

MD131A MECHANICAL PIPING DEMOLITION FLOOR PLAN - AREA A

MD131B MECHANICAL PIPING DEMOLITION FLOOR PLAN - AREA B

MD131C MECHANICAL PIPING DEMOLITION FLOOR PLAN - AREA C

MD401 ENLARGED DEMOLITION PLANS - AREA B AND AREA C

M-101A HVAC FLOOR PLAN - AREA A

M-101A2 HVAC FIRST FLOOR PLAN - AREA A2

M-101B HVAC FLOOR PLAN - AREA B

M-101B2 HVAC FLOOR PLAN - MINOR CONSTRUCTION AREA B2

M-101C HVAC FLOOR AND ROOF PLAN - AREA C

M-102A2 HVAC MEZZANINE PLANS - AREA A2

M-105A HVAC ROOF PLAN - AREA A

M-105B HVAC ROOF PLAN - AREA B

M-131A MECHANICAL PIPING FLOOR PLAN - AREA A

M-131A2 MECHANICAL FIRST FLOOR PLAN - AREA A2

M-131B MECHANICAL PIPING FLOOR PLAN - AREA B

M-131B2 MECHANICAL FLOOR PLAN - MINOR CONSTRUCTION AREA B2

M-131C MECHANICAL PIPING FLOOR PLAN - AREA C

M-132A2 MECHANICAL MEZZANINE PLANS - AREA A2

M-401 ENLARGED PLANS - AREA B, AREA C AND AREA D

M-501 MECHANICAL DETAILS

M-502 MECHANICAL DETAILS

M-503 MECHANICAL DETAILS

M-504 MECHANICAL DETAILS

M-601 MECHANICAL SCHEDULES

M-602 MECHANICAL SCHEDULES

M-603 MECHANICAL SCHEDULES

M-604 MECHANICAL SCHEDULES

M-605 MECHANICAL SCHEDULES

M-606 MECHANICAL SCHEDULES

M-607 MECHANICAL SCHEDULES

M-608 MECHANICAL SCHEDULES

M-609 MECHANICAL SCHEDULES

M-711 MECHANICAL SCHEMATICS

M-712 MECHANICAL SCHEMATICS

M-801 MECHANICAL CONTROL SCHEMATICS

M-802 MECHANICAL CONTROL SCHEMATICS

M-803 MECHANICAL CONTROL SCHEMATICS

M-804 MECHANICAL CONTROL SCHEMATICS

M-805 MECHANICAL CONTROL SCHEMATICS

Sheets in Volume: 96

SHEET INDEX - VOLUME 4

GENERAL

G-001D SHEET INDEX - VOLUME 4

ELECTRICAL

E-001 NOTES, SYMBOLS & ABBREVIATIONS

ED101A FIRST FLOOR ELECTRICAL DEMOLITON PLAN - AREA A

ED101B FIRST FLOOR ELECTRICAL DEMOLITON PLAN - AREA B

ED101C FIRST FLOOR & ROOF ELECTRICAL DEMOLITION PLAN - AREA C

ED102A MEZZANINE FLOOR & CATWALK LEVEL ELECTRICAL DEMOLITION PLAN - AREA A

ED102B ROOF ELECTRICAL & LIGHTNING PROTECTION DEMOLITION PLAN - AREA B

ED103A ROOF ELECTRICAL & LIGHTNING PROTECTION DEMOLITION PLAN - AREA A

ED701 DEMOLITION ONE-LINE DIAGRAM

E-100A HAZARDOUS AREA CLASSIFICATION PLAN

E-101A FIRST FLOOR POWER PLAN - AREA A

E-101A2 FIRST FLOOR POWER PLAN - AREA A2

E-101B FIRST FLOOR POWER PLAN - AREA B

E-101B2 FIRST FLOOR POWER PLAN - MINOR CONSTRUCTION - AREA B2

E-101C FIRST FLOOR & ROOF POWER PLAN - AREA C

E-102A MEZZANINE FLOOR & CATWALK LEVEL POWER PLAN - AREA A

E-103A ROOF POWER & LIGHTNING PROTECTION PLAN - AREA A

E-103B ROOF POWER & LIGHTNING PROTECTION PLAN - AREA B

E-103B2 ROOF POWER & LPS PLAN - MINOR CONSTRUCTION - AREA B2

E-121A FIRST FLOOR LIGHTING PLAN - AREA A

E-121A2 FIRST FLOOR LIGHTING PLAN - AREA A2

E-121B FIRST FLOOR LIGHTING PLAN - AREA B

E-121B2 FIRST FLOOR LIGHTING PLAN - MINOR CONSTRUCTION - AREA B2

E-121C FIRST FLOOR LIGHTING PLAN - AREA C

E-122A MEZZANINE FLOOR & CATWALK LEVEL LIGHTING PLAN - AREA A

E-401 ENLARGED POWER & DEMOLITION PLANS

E-402 ENLARGED POWER PLANS

E-403 ENLARGED PLANS

E-404 ENLARGED PHOTOS

E-405 ENLARGED PHOTOS

E-501 ELECTRICAL DETAILS

E-502 ELECTRICAL DETAILS

E-601 LUMINAIRE SCHEDULES

E-602 LIGHTING CONTROL SCHEDULES & CONTROLS NARRATIVE

E-603 EQUIPMENT WIRING SCHEDULES

E-604 EQUIPMENT WIRING SCHEDULES

E-605 PANEL SCHEDULES

E-606 PANEL SCHEDULES

E-607 PANEL SCHEDULES

E-608 PANEL SCHEDULES

E-701 ONE-LINE DIAGRAM

E-702 ONE-LINE DIAGRAM

TECHNOLOGY SYSTEMS

T-001 NOTES, SYMBOLS & ABBREVIATIONS

TD101A FIRST FLOOR TECHNOLOGY DEMOLITION PLAN - AREA A - HANGAR

TD101B FIRST FLOOR TECHNOLOGY DEMOLITION PLAN - AREA B - NORTH WING

TD101C FIRST FLOOR & ROOF TECHNOLOGY DEMOLITION PLAN - AREA C - EAST WING

TD102A MEZZANINE FLOOR & CATWALK LEVEL TECHNOLOGY DEMOLITION PLAN - AREA A - HANGAR

TD103A ROOF TECHNOLOGY DEMOLITION PLAN - AREA A - HANGAR

T-100 TECHNOLOGY SITE PLAN

T-101A FIRST FLOOR - AREA A - TECHNOLOGY SYSTEMS

T-101A2 HANGAR SHOP - AREA A2 - TECHNOLOGY SYSTEMS

T-101B FIRST FLOOR - AREA B - TECHNOLOGY SYSTEMS

T-101B2 FIRST FLOOR - AREA B2 - TECHNOLOGY SYSTEMS

T-101C FIRST FLOOR - AREA C - TECHNOLOGY SYSTEMS

T-102 MEZZANINE PLANS - TECHNOLOGY SYSTEMS

T-103A ROOF TECHNOLOGY PLAN - AREA A

T-121A FIRST FLOOR - AREA A - SECURITY

T-121A2 HANGAR SHOP - AREA A2 - SECURITY SYSTEMS

T-121B FIRST FLOOR - AREA B - SECURITY

T-121B2 FIRST FLOOR - AREA B2 - SECURITY

T-121C FIRST FLOOR - AREA C - SECURITY

T-123A ROOF SECURITY PLAN - AREA A

T-401 ENLARGED PLANS

T-402 ENLARGED PLANS

T-403 ENLARGED PLANS

T-404 ENLARGED PLANS

T-405 ENLARGED PLANS

T-501 DETAILS

T-502 DETAILS

T-503 DETAILS

T-701 ONE-LINE DIAGRAMS

Sheets in Volume: 71

XX

RTS

FAA

FMCP

LOC

WP

XX

AIM

A0M

SPD

XX

GENERAL NOTES:

PROVIDE NEW COMBINATION FIRE ALARM AND MASS NOTIFICATION SYSTEM (MNS) IN

ACCORDANCE WITH UFC 4-021-01, UFC 3-600-01, NFPA 72, OTHER REFERENCED CODES

AND STANDARDS, PROJECT SPECIFICATIONS, AND DESIGN DOCUMENTS. THE SYSTEM

SHALL HAVE THE ABILITY TO BROADCAST BOTH PRE-RECORDED AND LIVE VOICE

MESSAGES. THE FIRE ALARM AND MASS NOTIFICATION SYSTEM SHALL UTILIZE

SHARED SPEAKERS. THE MNS SHALL HAVE THE HIGHEST PRIORITY.

FIRE ALARM AND MASS NOTIFICATION CIRCUITS SHALL BE CLASS "B", SURVIVABILITY

LEVEL 1, IN ACCORDANCE WITH NFPA 72.

PROVIDE A NEW MONACO BT-XM RADIO TRANSCEIVER TO TRANSMIT ALARM,

SUPERVISORY, AND TROUBLE SIGNALS TO THE EXISTING BASE MONITORING STATION.

THE NEW SYSTEM SHALL BE FULLY COMPATIBLE WITH EXISTING MONACO RECEIVING

EQUIPMENT AND SHALL HAVE THE CAPABILITY FOR INTERFACE WITH FUTURE BASE-

WIDE MASS NOTIFICATION FUNCTIONS.

PROVIDE AUDIBLE (SPEAKERS) AND VISUAL NOTIFICATION APPLIANCES THROUGHOUT

ALL SPACES OF THE BUILDING, PROVIDE VISUAL COMBINED FIRE ALARM MASS

NOTIFICATION STROBES (CLEAR, MARKED "ALERT") SPACED IN ACCORDANCE WITH

NFPA 72.

PROVIDE EXTERIOR SPEAKERS ON THE EXTERIOR WALL OF THE BUILDING AT EACH

EXIT DOOR LOCATION PER UFC 4-021-01 TO PROVIDE FIRE ALARM AND MNS

ANNOUNCEMENTS. EXTERIOR SPEAKERS SHALL BE WEATHER RESISTANT TYPE.

PROVIDE A LOCAL OPERATING CONSOLE (LOC) AS SHOWN ON THE FLOOR PLAN.

TYPICALLY EACH LOC IS LOCATED WITHIN 200 FEET OF TRAVEL ON EACH LEVEL OF

THE BUILDING;

THE BUILDING PUBLIC ADDRESS SYSTEM SHALL NOT BE COMBINED WITH THE FIRE

ALARM AND MNS SYSTEM. PROVIDE INTERFACE WITH PUBLIC ADDRESS (PA) SYSTEM

THAT WILL SILENCE THE PA SYSTEM UPON ACTIVATION OF A FIRE ALARM OR MNS

ANNOUNCEMENT.

PROVIDE REMOTE POWER SUPPLIES (NAC), IN ADDITION TO THOSE SHOWN ON THE

FLOOR PLAN, AS NEEDED TO SUPPORT THE FIRE ALARM AND MASS NOTIFICATION

SYSTEM. THE REMOTE POWER SUPPLIES ARE REQUIRED TO BE LOCATED WITHIN

ELECTRICAL ROOMS OR OTHER UTILITY SPACES. PROVIDE A SMOKE DETECTOR

ABOVE EACH REMOTE POWER SUPPLY IN ACCORDANCE WITH NFPA 72.

PROVIDE A SMOKE DETECTOR ABOVE THE FIRE ALARM AND MASS NOTIFICATION

CONTROL PANEL (FMCP) OR OTHER PIECE OF FIRE ALARM SYSTEM CONTROL

EQUIPMENT IN ACCORDANCE WITH NFPA 72. NOTE THE NFPA 72 DOES NOT REQUIRE

SMOKE DETECTION ABOVE THE REMOTE ANNUNCIATOR (FAA) OR THE LOCAL

OPERATING CONSOLE (LOC).

EACH ACOUSTICALLY DISTINGUISHABLE SPACE (ADS) SHALL NOT BE REQUIRED TO

COMPLY WITH GENERAL INTELLIGIBILITY REQUIREMENTS FOR THE BUILDING.

INSTEAD, INTELLIGIBILITY WITHIN EACH ADS SHALL COMPLY WITH UFC 4-021-01 WHICH

PERMITS AN OCCUPANT TO TRAVEL NO MORE THAN 30 FEET (NORMALLY OCCUPIED

AREAS) OR 50 FEET ( NORMALLY UNOCCUPIED AREAS) TO A LOCATION WHERE

INTELLIGIBILITY IS ACHIEVED. REFER TO THE "ACOUSTICALLY DISTINGUISHABLE

SPACE (ADS) AND NOTIFICATION LEGEND" AND ASSOCIATED HATCHING ON THE

FLOOR PLAN FOR MORE INFORMATION.

THE GENERAL MINIMUM INTELLIGIBILITY CIS SCORE IS 0.8 FOR THE ARMY AND AIR

FORCE PER UFC 4-021-01, 4-4.1.2. NOTE THAT CIS SCORES OF 0.75 - 0.79 MAY BE

ROUNDED UP THE 0.8.

THE LAYOUT OF DEVICES, APPLIANCES, CONTROL EQUIPMENT, AND OTHER SYSTEM

COMPONENTS ON THESE DRAWINGS SHOWS THE MINIMUM NUMBER OF

COMPONENTS. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ADDITIONAL

DEVICES, APPLIANCES, CONTROL EQUIPMENT, AND OTHER SYSTEM COMPONENTS AS

REQUIRED TO COMPLY WITH THE APPLICABLE CODES, STANDARDS, SPECIFICATIONS,

AND DESIGN CRITERIA. THE CONTRACTOR SHALL PROVIDE A SYSTEM THAT MEETS

THE AUDIBILITY AND INTELLIGIBILITY OF UFC 4-021-01 AND AUDIBLE AND VISIBLE

REQUIREMENTS OF NFPA 72. PERFORMANCE RESULTS, INCLUDING THE REQUIRED

SOUND PRESSURE LEVELS AND INTELLIGIBILITY VALUES, SHALL BE DOCUMENTED ON

A FLOOR PLAN AND SUBMITTED TO THE GOVERNMENT.

CONTRACTOR SHALL PROVIDE INTERFACE WITH THE WATERFLOW AND VALVE

TAMPER SWITCHES FOR MONITORING OF THE FIRE SUPPRESSION SYSTEMS. NUMBER

OF DEVICES AND LOCATIONS SHALL BE COORDINATED WITH THE FIRE SUPPRESSION

SYSTEM SUBCONTRACTOR.

PROVIDE HVAC SHUTDOWN SWITCHES CAPABLE OF SHUTTING DOWN ALL HVAC

EQUIPMENT IN THE FACILITY IN ACCORDANCE WITH UFC 4-101-01. PROVIDE HVAC

SHUTDOWN SWITCHES NEAR EACH OF THE LOCAL OPERATING CONSOLES IN

LOCATION APPROVED BY THE CONTRACTING OFFICER. COORDINATE WITH THE

MECHANICAL CONTRACTOR AND REFER TO THE MECHANICAL DRAWINGS.

PROVIDE DUCT SMOKE DETECTION IN HVAC SYSTEM IN ACCORDANCE WITH NFPA 90A

(2015 EDITION). NUMBER OF DEVICES AND LOCATIONS SHALL BE COORDINATED WITH

THE MECHANICAL CONTRACTOR. PROVIDE REMOTE TEST STATIONS WHERE DUCT

DETECTORS ARE INSTALLED IN LOCATIONS OVER 1.8m ABOVE THE FLOOR.

LOCATIONS THAT ARE NOT EASILY ACCESSIBLE, OR WHERE DUCT DETECTORS ARE

LOCATED ABOVE CEILINGS.

PROVIDE MANUAL PULL STATIONS AT EACH OF THE EXTERIOR DOORS AND AT

ENTRANCES TO EXIT STAIRS IN ACCORDANCE WITH NFPA 72 AND UFC 3-600-01.

THE FIRE ALARM AND MASS NOTIFICATION SYSTEM SHALL MONITOR THE FIRE PUMPS

AND FIRE SUPPRESSION SYSTEM EQUIPMENT IN ACCORDANCE WITH NFPA 72, NFPA

20, AND UFC 3-600.01.

PROVIDE NEMA 250 TYPE 4 WALL MOUNTED DEVICES AND APPLIANCES WITHIN THE

HANGAR BAY (INCLUDING BACKBOXES). PROVIDE WATERTIGHT CONDUIT AND

JUNCTION BOXES THROUGHOUT HANGAR BAY.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

FIRE ALARM & MASS NOTIFICATION LEGEND

SMOKE DETECTOR

CLEAR STROBE (XX = CANDELA RATING)

SPEAKER APPLIANCE

DUCT DETECTOR

REMOTE TEST SWITCH FOR DUCT DETECTOR

HORN APPLIANCE (WEATHERPROOF)

ELECTRIC FIRE ALARM BELL

(WEATHERPROOF)

SUPERVISORY (TAMPER) SWITCH

WATER FLOW SWITCH

FIRE ALARM GRAPHIC ANNUNCIATOR

FIRE ALARM / MASS NOTIFICATION CONTROL PANEL

LOCAL OPERATING CONSOLE

FIRE ALARM MANUAL PULL STATION

COMBINATION SPEAKER - STROBE APPLIANCE

AMBER STROBE (XX = CANDELA RATING)

(MAY BE COMBINED WITH SPEAKER APPLIANCES)

MNS

ADDRESSABLE OUTPUT MODULE

ADDRESSABLE INPUT MODULE

VS

WF

SURGE PROTECTIVE DEVICE

DET-TRONICS CONTROL PANELDET

CO CARBON MONOXIDE DETECTOR

DET-TRONICS X3301 OPTICAL FLAME DETECTOR

SYSTEM INPUTS

MANUAL PULL STATION

A U

D

IO

-V

IS

U A

L F

IR

E

A L A

R M

I N

D

IC

A T

IO

N

B Y

D E

V

IC

E

CONTROL UNIT

ANNUNCIATION

A U

D

IO

-V

IS

U A

L S

U P

E R

V

IS

O R

Y I N

D

IC

A T

IO

N

B Y

D E

V

IC

E

A U

D

IO

-V

IS

U A

L T

R O

U B

L E

I D

E N

T

IF

IC

A

T

IO

N

B Y

D E

V

IC

E

A U

D

IO

-V

IS

U A

L S

U P

E R

V

IS

O R

Y I N

D

IC

A T

IO

N F

O R

F A

S O

V E

R R

ID

E

B Y

M N

S

F

IR

E A

L A

R M

S

IG

N A

L

B Y

D E

V

IC

E T

Y P

E

G E

N E

R A

L S

U P

E R

V

IS

O R

Y S

IG

N

A L

G E

N E

R A

L T

R O

U B

L E

S

IG

N A

L

TRANSMIT TO

BASE RECIEVING

STATION

NOTIFICATION

SIGNALS

TAMPER SWITCH

FAS / MNS SYSTEM LOW BATTERY

GROUND FAULT

NOTIFICATION APPLIANCE SHORT CIRCUIT

RADIO SIGNAL - SINGLE FAULT

SYSTEM OUTPUTS

OPEN CIRCUIT

A B C D E F G H I J K M

F

IR

E A

L A

M

S

IG

N A

L S

S U

P E

R V

IS

O

Y

N A

L

FAS / MNS AC POWER FAILURE

T R

O U

B

E

N A

L S

L

WATER FLOW SWITCH - WET-PIPE SPRINKLER SYSTEM

SMOKE DETECTOR - ABOVE FACP

MANUAL MNS ACTIVATION AT FMCP/LOC

MANUAL HVAC SHUTDOWN AT LOC

CONCURRENT FAS & MNS ACTIVATION

RADIO SIGNAL - INTERFERENCE

RADIO SIGNAL - REMOVAL

S U

P E

R V

IS

O

R Y

S

IG

N A

L F

O R

F A

S O

V E

R R

ID

E

B Y

M N

S

A C

T U

A T E

F A

S M

N S

V

IS

U A

L N

O T

IF

IC

A

T

IO

N

P

P L

IA

N C

E S

S

T R

O B

E S

A N

D L

E D

S

IG

N S

A C

T U

A T E

F A

S M

N S

A U

D

IB

L E

N O

T

IF

IC

A

T

P L

IA

N C

E S

S

P E

A K

E R

S

T E

M P

O R

A R

IL

Y

S

IL

E N

C E

F A

S S

Y S

T E

M A

U D

IB

T

IF

IC

A

T

IO

N A

C T U

A T E

E X

T E

R

IO

R F

A S

M

N S

A U

D

IB

T

IF

IC

A

T

IO

N A

P P

L

IA

N C

E S

S

P E

A K

E R

S

A C

T U

A T E

E X

T E

R

IO

R W

A T E

R F L O

W A

L A

R M

B E

L L

AUXILIARY

FUNCTIONS

N O

A C

T

IV

A T E

R E

L A

Y T

O S

H U

T D

O W

N H

V A

C S

Y S

T

Q

U

IP

M E

N T

A C

T

IV

A T E

R E

L A

Y T

O I N

IT

IA

T E

F

IR

E P

U M

P

P

DRY PIPE SPRINKLER SYSTEM - SUPERVISORY PRESSURE SWITCH

FIRE PUMP RUNNING

DUCT SMOKE DETECTOR

(NOT USED)

A C

T U

A T E

E X

T E

R

IO

R D

IV

E

R T E

R V

A L V

E

FIRE PUMP LOSS OF POWER 13

FIRE PUMP PHASE REVERSAL 14

(NOT USED)

DIVERTER VALVE MANUAL PULL STATION

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

ISSUED

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281

/1

/2

:0 :0

A

M C

R e v it L o c a l\

.0

-E

-R

D a n .G o ld b e rg G

C S

L

.r v t

NOTES & SYMBOLS

NOT FOR CONSTRUCTION

FJRP112701ANG PRO. NO.:

3258000-131303.01

DEG

MAM

April 25, 2022

DEG

N C

A N

G

T

H A

W

C H

A R

L O

T T

E D

O U

G L A

S I A

P C

H A

R L O

T T

E N

O R

T H

C A

R O

L

IN

A

R E

P A

IR

M

A

IN

T E

N A

N C

E H

A N

G A

R B

U

IL

D

IN

G

FA001

NO SCALE1

Fire Alarm Ops Matrix

C

LO

C

P

P

P

P

P

P

P

P

E5

E4

E3

E2

E1

EC

EB

EA

N9 N8 N7 N6 N5N4 N3 N2 N1

ND

NC

NB

NA

HG

7.7

7.3

E

D

C

B

A

F J

K

5.001

5.001

5.001

DEMO NOTES:

THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE

INTENDED TO INDICATE THE SCOPE OF WORK REQUIRED. THE

CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING A BID

AND VERIFY EXISTING CONDITIONS.

DASHED WALLS ON THE FLOOR PLANS INDICATE EXISTING WALLS

BEING DEMOLISHED. REFER TO THE ARCHITECTURAL DEMOLITION

PLANS FOR THE EXACT EXTENT OF WORK REQUIRED BY THIS

PROJECT.

THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN IN OPERATION

THROUGHOUT AREAS OUTSIDE OF ARCHITECTURAL SCOPE OF

CONSTRUCTION PRIOR TO DEMOLITION OF THE FIRE ALARM SYSTEM

COMPONENTS IN THOSE SPACES. DURING THE DEMOLITION OF THE

FIRE ALARM SYSTEM TEMPORARY HEAT DETECTORS SHALL BE

CONNECTED TO A SPARE CIRCUIT OF THE FIRE ALARM SYSTEM

WHEN THE SPACE IS OCCUPIED BY THE CONTRACTOR. WHERE

TEMPORARY HEAT DETECTORS ARE NOT FEASIBLE, THE

CONTRACTOR SHALL PROVIDE TRAINED ROAMING FIRE WATCH

DURING SYSTEM OUTAGES.

WHERE FIRE ALARM DEVICES ARE BEING REMOVED, ALL

ASSOCIATED CONDUIT AND WIRE BACK TO THE ASSOCIATED FIRE

ALARM PANEL OR JUNCTION BOX SERVING THE DEVICE SHALL ALSO

BE REMOVED. THE CONTRACTOR SHALL DISPOSE OF MATERIAL THE

OWNER DOES NOT WANT TO REUSE OR RETAIN FOR MAINTENANCE

PURPOSES.

ALL BOXES THAT REMAIN IN PLACE IN EXISTING MASORY WALLS

THAT ARE TO REMAIN SHALL BE PROVIDED WITH A BLANK

COVERPLATE.

ALL CONDUIT SHALL BE REMOVED WHERE WALLS ARE BEING

REMOVED. WHERE CONDUT IS IN THE CONCRETE SLAB, CUT OFF

FLUSH, PULL OUT WIRE, AND PLUG. WHERE CONDUIT IS RUN

EXPOSED, ALL ASSOCIATED CLAMPS, SUPORTS, HANGERS, ETC.,

SHALL ALSO BE REMOVED. CONDUIT CONCEALED IN WALL

CONSTRUCTION MAY BE ABANDONED IN PLACE IF NOT AFFECTED BY

OTHER CONSTRUCTION.

THE CONTRACTOR SHALL COORDINATE ALL WORK, INCLUDING

PHASING, WITH OTHER CONTRACTORS AT THE JOB SITE BEFORE

REMOVING EXISTING FIRE ALARM DEVICES AND INSTALLING NEW

ITEMS.

EXISTING CONDUIT IN GOOD CONDITION MAY BE REUSED IN PLACE.

RELOCATION OF EXISTING CONDUIT SHALL NOT BE PERMITTED.

1.

2.

3.

4.

5.

6.

7.

8.

KEY PLAN

A

B

C

SHOP

SOUTH

SHOP

NORTH

B2

A2

A2

C2

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

ISSUED

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281

/1

/2

:0 :4

A

M C

R e v it L o c a l\

.0

-E

-R

D a n .G o ld b e rg G

C S

L

.r v t

FIRE ALARM

OVERALL DEMO

PLAN

NOT FOR CONSTRUCTION

FJRP112701ANG PRO. NO.:

3258000-131303.01

DEG

MAM

April 25, 2022

DEG

N C

A N

G

T

H A

W

C H

A R

L O

T T

E D

O U

G L A

S I A

P C

H A

R L O

T T

E N

O R

T H

C A

R O

L

IN

A

R E

P A

IR

M

A

IN

T E

N A

N C

E H

A N

G A

R B

U

IL

D

IN

G

FAD101

3/64" = 1'-0"1

FIRE ALARM OVERALL DEMO PLAN

KEYED NOTES

5.001 REMOVE ALL FIRE ALARM DEVICES, CONDUCTORS, CONNECTORS, AND

CONDUIT IN HATCHED AREA.

EF.

R E

F

R E F.

DN

DN

FACP

M M

M

M

M

M

M

M

M M

M M

M

M

M

M

MM

M

M

M

M

M

M

M

M

M

MM

M M

M

LOC

LO

C

M

M

DET

CO

CO

CM

E5

E4

E3

E2

E1

EC

EB

EA

N7

N6

N5N4

N3

N2 N1

ND

NC

NB

NA

H

G

10 9 8

7.7 7.3

E

D

C

B

A

11 7 6 5 4 3 2 1

F

J

K

HANGAR

H100

HYDRO

WORK

AREA

H145

BATTERY

ROOM

H135

ELEC

WORK

AREA

H134

HYDRO

ADMIN

H144

ELEC

ADMIN

H142

LOX

CART

ROOM

H132

OPEN

OFFICE

H112

ELEC./MECH.

RM.

H118

SPRINKLER

ROOM

H115

FA103

FA104

5.105

5.103

5.103

5.103

5.103

5.103

5.103

5.102

5.102

5.104 5.101

5.101

5.106

KEY PLAN

A

B

C

SHOP

SOUTH

SHOP

NORTH

B2

A2

A2

C2

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

ISSUED

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281

/1

/2

:0 :1

A

M C

R e v it L o c a l\

.0

-E

-R

D a n .G o ld b e rg G

C S

L

.r v t

FIRE ALARM AND

MNS FLOOR PLAN

HANGAR

NOT FOR CONSTRUCTION

FJRP112701ANG PRO. NO.:

3258000-131303.01

DEG

MAM

April 25, 2022

DEG

N C

A N

G

T

H A

W

C H

A R

L O

T T

E D

O U

G L A

S I A

P C

H A

R L O

T T

E N

O R

T H

C A

R O

L

IN

A

R E

P A

IR

M

A

IN

T E

N A

N C

E H

A N

G A

R B

U

IL

D

IN

G

FA102

1/16" = 1'-0"1

FIRE ALARM AND MNS FLOOR PLAN HANGAR

KEYED NOTES

5.101 PROVIDE CARBON MONOXIDE DETECTOR FOR ERV UNIT ON MEZZANINE

LEVEL. SEE MECHANICAL DRAWINGS FOR EXACT LOCATION.

5.102 MANUAL DIVERTER VALVE PULL STATION

5.103 DET-TRONICS X3301 OPTICAL FLAME DETECTOR.

5.104 DET-TRONICS CONTROL PANEL

5.105 CLASS I DIV 2 BATTERY STORAGE AREA.

5.106 PROVIDE WEATHERPROOF CONTROL MODULE FOR DIVERTER VALVE

ACTUATION IN DIVERTED VALVE VAULT. SEE CIVIL DRAWINGS FOR EXACT

LOCATION.

DN

MM

M

M

M

M M

M

M

M

M

M

M

MM

M

M

M

M

MM

M

M

M

MM

MM

M

M

M

M

M

MM

M

M

M M

M

M

MMM

M

M

MM

M

MM

M

L O

C

N9 N8 N7 N6 N5N4 N3 N2 N1

ND

NC

NB

NA

H G

10 9 8 7.7

E

D

F J

K

AMXS

CHIEF

N153B

AMXS

FLIGHT

CHIEF

N153A

AMXS

FLIGHT

CHIEF

N153C

AMXS

FLIGHT

CHIEF

N153F

CORRIDOR

N153

AMXS

FLIGHT

CHIEF

N153E

COPY/PRINT

N153D

FOYER

N160

CORRIDOR

N150

SUPPORT

EQUIPMENT

N152

MECHANICAL

ROOM

N161

STORAGE

N113B

READY/BREAK

ROOM

N151

SHIRT

OFFICE

N143

COMMANDER

N141

CTK

N131

CTK

CHECKOUT

N131A

VESTIBULE

N132

CORRIDOR

N130

BOEING

REP

N125A

WOMEN

N124

MENS

N123

OPEN

OFFICE

N125

MENS

LOCKER

N121A

MENS

N121

CORRIDOR

N120

MOO

N142

PRO

SUP

N144

STORAGE

N145

JANITOR/LAUNDRY

N146

BREAK

ROOM

N122

ENGINE

WORKROOM

N113

PW

OFFICE

N111

PMEL

STORAGE

N112

ENG

ELEMENT

CHIEF

N113A VESTIBULE

N109

AVIONICS

ELEMENT

CHIEF

N116

CMF

CHIEF

N117

CONFERENCE

N118

CORRIDOR

N107

PASSAGE

N115

AVIONICS

N110

SIPR

N110A

AVIONICS

STORAGE

N110B

COMSEC

N110AA

CORRIDOR

N101

VESTIBULE

N100

ELEC.

ROOM

N102

WOMEN

N104

REF.

PLAN OF THIS AREA

FOR2/ FA104

FA104

KEY PLAN

A

B

C

SHOP

SOUTH

SHOP

NORTH

B2

A2

A2

C2

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

ISSUED

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281

/1

/2

:0 :2

A

M C

R e v it L o c a l\

.0

-E

-R

D a n .G o ld b e rg G

C S

L

.r v t

FIRE ALARM AND

MNS FLOOR PLAN

NORTH WING

NOT FOR CONSTRUCTION

FJRP112701ANG PRO. NO.:

3258000-131303.01

DEG

MAM

April 25, 2022

DEG

N C

A N

G

T

H A

W

C H

A R

L O

T T

E D

O U

G L A

S I A

P C

H A

R L O

T T

E N

O R

T H

C A

R O

L

IN

A

R E

P A

IR

M

A

IN

T E

N A

N C

E H

A N

G A

R B

U

IL

D

IN

G

FA103

1/8" = 1'-0"1

FIRE ALARM AND MNS FLOOR PLAN NORTH WING

REF.

M

M

M

M

M M

M

M M

M M

M

M

M

MM

M

M

M

M M

M

M

M

M

LOC

M

M

DN

M

M

M

MM

E5

E4

E3

E2

E1

EC

EBEA

H

G

F

J

K

VESTIBULE

E125

MEN

E122

OPEN

OFFICE

E123

CHIEF

INSPECTOR

E123A

QA

SUPER

E123B

STORAGE

E123D

TESTING

E107A

COMM

E119

ELEC

E116

WOMEN

E120

CORRIDOR

E115

BREAK

E117

CLASSROOM

E108

UTM

OFFICE

E107

CONF

ROOM

E123C

FOYER

E101

VESTIBULE

E100

DCM.

E104

MXG/CC

E105

MXG/ADM

E103

CCC

E106

OPEN

OFFICE

E102MECH.

E126

STORAGE

E108A

N9 N8 N7 N6 N5N4

NB

NA

E12

D

F

CTK

N131

CTK

CHECKOUT

N131A

BATTERY

STORAGE

H135A

CORRIDOR

N130

VESTIBULE

N132

KEY PLAN

A

B

C

SHOP

SOUTH

SHOP

NORTH

B2

A2

A2

C2

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

ISSUED

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281

/1

/2

:0 :2

A

M C

R e v it L o c a l\

.0

-E

-R

D a n .G o ld b e rg G

C S

L

.r v t

FIRE ALARM AND

MNS ENLARGED

FLOOR PLAN EAST

WING

NOT FOR CONSTRUCTION

FJRP112701ANG PRO. NO.:

3258000-131303.01

DEG

MAM

April 25, 2022

DEG

N C

A N

G

T

H A

W

C H

A R

L O

T T

E D

O U

G L A

S I A

P C

H A

R L O

T T

E N

O R

T H

C A

R O

L

IN

A

R E

P A

IR

M

A

IN

T E

N A

N C

E H

A N

G A

R B

U

IL

D

IN

G

FA104

1/8" = 1'-0"1

FIRE ALARM AND MNS ENLARGED FLOOR PLAN EAST WING

1/8" = 1'-0"2

FIRE ALARM AND MNS ENLARGED FLOOR PLAN AREA B2 - MINOR CONSTRUCTION

FIRE ALARM & MASS NOTIFICATION SYSTEM NOTES:

1. FIRE ALARM CONTROL UNIT AND MASS NOTIFICATION AUTONOMOUS CONTROL UNIT (FMCP) IS A COMBINED UNIT OF THE FIRE ALARM CONTROL PANEL (FACP) AND THE MNS AUTONOMOUS CONTROL UNIT (ACU). THE UNIT COULD USE

ONE OR MORE ENCLOSURES.

2. MASS NOTIFICATION ACU SHALL BE INTERFACED WITH THE TELEPHONE SYSTEM, SO THAT ANNOUNCEMENTS MAY BE

MADE OVER THE FA / MNS SPEAKERS VIA THE TELEPHONE SYSTEM.

3. ALL DETECTION AND ALARM CIRCUITS SHALL BE OF THE SUPERVISED CLASS A, STYLE D FOR INITIATING CIRCUITS AND A SUPERVISED CLASS A, STYLE Z FOR NOTIFICATION APPLIANCE CIRCUITS. SIGNALING LINE CIRCUITS (SLC) SHALL BE CLASS A, STYLE 2α.

4. MONITORED DEVICES INCLUDE FLOW AND TAMPER SWITCHES.

5. IF NOTIFICATION APPLIANCE CIRCUIT (NAC) POWER SUPPLIES OR AMPLIFIERS ARE REQUIRED, LOCATIONS SHALL BE APPROVED BY THE OWNER AND SHALL BE ACCESSIBLE TO THE FIRE DEPARTMENT. PROVIDE SMOKE DETECTOR (NOT SHOWN ON FLOOR PLANS) AT EACH NAC POWER SUPPLY/AMPLIFIER LOCATION UNLESS THE ROOM IS COVERED BY AREA SMOKE DETECTION. PROVIDE 120V POWER TO EACH LOCATION. NOTE THE SPEAKERS IN THE SECURE AREA

SHALL HAVE THEIR OWN HIGH GAIN POWER AMPLIFIER.

6. SEE PLANS FOR SPECIFIC CANDELA (CD) RATINGS ON NOTIFICATION APPLIANCES

7. ALL JUNCTION, TERMINAL, AND PULLING BOXES AND COVERS SHALL BE PAINTED RED AND SHALL BE IDENTIFIED WITH ENGRAVED LABELS BY CIRCUIT THAT IT CONTAINS. ALL CONDULETS AND SIMILAR UNITS SHALL BE PAINTED RED. ALL DETECTION AND TERMINAL DEVICES SHALL HAVE ENGRAVED PLASTIC OR METALLIC ALPHANUMERIC IDENTIFICATION, WHICH SHALL BE KEYED TO THE POSTED AND OPERATIONS AND MAINTENANCE INSTRUCTIONS.

8. ALL WIRING SHALL BE PER MANUFACTURER'S RECOMMENDATIONS.

9. WHEN THE MNS IS ANNOUNCING, AUDIBLE AND VISUAL FIRE ALARMS SHALL BE DE-ENERGIZED. CONTRACTOR SHALL

SUPPLY ALL NECESSARY EQUIPMENT TO ACCOMPLISH THIS PROCEDURE.

10. ALL SPEAKER AND STROBE CIRCUITS SHALL BE SUPERVISED.

11. STROBES SHALL BE DUAL AMBER/CLEAR TYPE WITH SEPARATE CABLING TO EACH STROBE.

12. SEE DRAWING FOR EXACT LOCATION OF REMOTE LOCAL OPERATION CONSOLE (LOC).

13. EMERGENCY EYEWASH STATIONS SHALL EACH HAVE A HORN/STROBE NOTIFICATIONS APPLIANCE AND A FLOW SWITCH. IF THE STATION IS USED THE FLOW SWITCH SHALL PROVIDE A TROUBLE ALARM AT THE FACP, AND THE HORN/STROBE LOCATED AT THE SPECIFIC EYEWASH STATION THAT HAS BEEN USED SHALL BE ENERGIZED.

CDCD CD

CDCDCDCD

CD

24V POWER

SLC CIRCUIT

ANTENNA CABLING

FIRE ALARM

CONTROL PANEL

(FACP)

MNS

AUTONOMOUS

CONTROL UNIT

(ACU)

ROOM H115

120 VAC

LOC CORRIDOR H116

TO OTHER DUAL AMBER/CLEAR STROBES

AND THEN BACK TO FACP/ACU

TO OTHER SPEAKERS

AND THEN BACK TO FACP/ACU

TO OTHER DUAL AMBER/CLEAR STROBES

AND THEN BACK TO FACP/ACU

TO OTHER SPEAKERS

AND THEN BACK TO AMPLIFIER

TO OTHER EQUIPMENT

AND THEN BACK TO FACP/ACU

MONITORED

DEVICE

CONTROLLED

DEVICE

S SSS

S S S S

MM CMDS

RTS/I

SPD

FIRE ALARM / MNS

CONTROL PANEL

(FMCP)

DET-TRONICS

CONTROL PANEL

(DET)

120 VAC

SPD

TO OTHER FLAME DETECTION

DEVICES AND THEN BACK TO DET

LOC CORRIDOR N153

LOC OPEN OFFICE E102

CONTROL UNIT

ANNUNCIATION

A U

D

IO

-V

IS

U A

L F

IR

E A

LA

R

M

IN

D

IC

A T

IO

N

B Y D

E V

IC

E

A U

D

IO

-V

IS

U A

L S

U P

E R

V

IS

O R

Y

IN

D

IC

A T

IO

N

B Y D

E V

IC

E

A U

D

IO

-V

IS

U A

L T R

O U

B

LE

ID

E

N T

IF

IC

A

T

IO

N

B Y

D E

V

IC

E

A U

D

IO

-V

IS

U A

L S

U P

E R

V

IS

O R

Y

IN

D

IC

A T

IO

N F

O R

F

V

E R

R

ID

E B

Y M

N S

F

IR

E A

LA

R

M S

IG

N

A L

B

Y D

E V

IC

E

T Y P

E

A B C D E F G

F

IR

E A

L A

N

A L S

MANUAL PULL STATION

WATER FLOW SWITCH - FLOOR SPRINKLER SYSTEM ZONE

SMOKE DETECTOR - ABOVE FMCU

G E

N E

R A

L S

U P

E R

V

IS

O R

Y S

IG

N

A L

G E

N E

R A

L T R

O U

B

LE

S

IG

N A

L

S U

P E

R V

IS

O

R Y S

IG

N

A L

F O

R F

A S

O V

E R

R

ID

E B

Y M

N S

TX TO BASE

REC. STATION

H

S U

P E

R V

IS

O

R Y

S

IG

N A

L S

TAMPER SWITCH

DRY PIPE SPRINKLER SYSTEM - SUPERVISORY PRESSURE SWITCH

MANUAL MNS ACTIVATION AT FMCU / LOC

CONCURRENT FAS & MNS ACTIVATION

DUCT SMOKE DETECTOR FOR HVAC SHUTDOWN

FAS / MNS AC POWER FAILURE

MANUAL HVAC SHUTDOWN AT LOC

FAS / MNS SYSTEM LOW BATTERY

OPEN CIRCUIT, SHORT CIRCUIT

GROUND FAULT

NOTIFICATION APPLIANCE SHORT CIRCUIT

RADIO SIGNAL - SINGLE FAULT

RADIO SIGNAL - INTERFERENCE

RADIO SIGNAL - REMOVAL

T R

O U

B L E

S

IG

N A

L S

A C

T U

A T E

F A

S /M

N S

V

IS

U A

L N

O T

IF

IC

A

T

P

LI

A N

C E

S S

T R

O B

E S

A N

D L

E D

S

IG

N S

A

C T U

A T E

E X T E

R

IO

R W

A T E

R F

LO

W A

LA

R

M B

E

LL

A C

T U

A T E

F A

S /M

N S

A U

D

IB

LE

N

O T

IF

IC

A

T

P

LI

A N

C E

S H

O R

N S

S

P E

A K

E R

S

T E

M P

O R

A R

IL

Y

S

IL

E N

C E

F A

S S

Y S

T E

M A

U D

IB

LE

T

IF

IC

A

T

IO

N

A C

T U

A T E

E X

T E

R

IO

R F

A S

/M N

S A

U D

IB

LE

T

IF

IC

A

T

IO

N A

P P

LI

A

N C

E S

S

P E

A K

E R

S

I J K L M

NOTIFICATION

SIGNALS

N O P

AUXILIARY

FUNCTIONS

A C

T

IV

A T E

R E

LA

Y T

O S

H U

T D

O W

N H

V A

C S

Y S

T

Q

U

IP

M E

N T

SYSTEM INPUTS

S Y

S T E

M O

U T P

U T S

S

E Q

U E

N C

E O

F O

P E

R A

T

IO

N S

NOTES:

1. TWO SEPARATE AND DISTINCT SIGNALS MUST BE INITIATED: ONE INDICATING MOVEMENT OF A

VALVE FROM ITS NORMAL POSITION (OFF-NORMAL), AND THE OTHER INDICATING RESTORATION

OF THE VALVE TO ITS NORMAL POSITION. (NFPA 72 SECTION 17.17.1.1)

2. SIMULTANEOUS FIRE ALARM AND MASS NOTIFICATION EVENTS MUST TRANSMIT A UNIQUE AND

DISTINCT SUPERVISORY SIGNAL.

ABBREVIATIONS:

FAS: FIRE ALARM SYSTEM

FMCU: FIRE ALARM AND MASS NOTIFICATION CONTROL UNIT

FSCS: FIRE FIGHTERS' SMOKE CONTROL STATION

LOC: LOCAL OPERATING CONSOLE

MNS: MASS NOTIFICATION SYSTEM

REC: RECEIVING

TX: TRANSMIT

FIRE PUMP - PHASE REVERSAL

FIRE PUMP - POWER FAILURE

FIRE PUMP - RUN

A C

T

IV

A T E

R E

LA

Y

T O

IN

IT

IA

T E

F

IR

E P

U M

P

A C

T

IV

A T E

R E

LA

Y

T O

IN

IT

IA

T E

D

IV

E R

T E

R V

A

LV

E

(NOT USED)

(NOT USED)

DIVERTER VALVE MANUAL PULL STATION

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

ISSUED

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281

/2

/2

:1 :4

A

M C

R e v it L o c a l\

.0

-E -R c h ri s .d o u g a n

.r v t

FIRE ALARM AND

MNS RISER

DIAGRAM AND

MATRIX

FJRP112701ANG PRO. NO.:

3258000-131303.01

Author

Checker

July 20, 2022

Designer

N C

A N

G

T

H A

W

C H

A R

L O

T T

E D

O U

G L A

S I A

P C

H A

R L O

T T

E N

O R

T H

C A

R O

L

IN

A

R E

P A

IR

M

A

IN

T E

N A

N C

E H

A N

G A

R B

U

IL

D

IN

G

FA105

07/20/22 B-3 SUBMITTAL

NO SCALE1

FIRE ALARM RISER DIAGRAM

NO SCALE2

FIRE ALARM MATRIX

FIRE PROTECTION GENERAL NOTES:

1. ABBREVIATIONS INDICATED HERE AND NOT USED IN THE CONTRACT

DOCUMENTS DO NOT APPLY TO THIS PROJECT. ADDITIONAL ABBREVIATIONS

MAY BE INDICATED IN THE CONTRACT DOCUMENTS.

2. THESE DRAWINGS ARE DESIGN DRAWINGS AND ARE DIAGRAMMATIC. THEY

MAY NOT SHOW ALL PHYSICAL ARRANGEMENTS, OFFSETS, BENDS, OR

ELBOWS WHICH MAY BE REQUIRED FOR INSTALLATION OF VARIOUS

MATERIALS, EQUIPMENT AND PIPING IN ALLOTTED SPACES. EXAMINE THESE

AND OTHER AVAILABLE DRAWINGS TO DETERMINE SPACE LIMITATIONS AND

INTERFERENCES. MAKE ANY MINOR CHANGES IN LOCATIONS OF EQUIPMENT

AND PIPING FROM THAT SHOWN ON DRAWINGS AND FOR ALL PHYSICAL

DETAILS REQUIRED FOR INSTALLATION. COST FOR ADAPTING WORK TO JOB

SITE CONDITIONS SHALL NOT BE CONSIDERED AS BASIS OF AN EXTRA COST

TO CONTRACT.

3. ELEVATION OF PIPING INDICATED ON THESE DRAWINGS ARE TO BE USED AS

GUIDELINES TO ASSIST WITH INSTALLATIONS. MINOR CHANGES TO THESE

ELEVATIONS MAY BE NECESSARY TO ELIMINATE UNFORESEEN

INTERFERENCES. ANY CHANGE IN ELEVATION SHALL BE APPROVED PRIOR TO

CHANGE.

4. ANY AND ALL INFORMATION SHOWN ON THESE DRAWINGS WITH RESPECT TO

EXISTING STRUCTURES, UTILITIES, AND MECHANICAL SYSTEMS IS AS EXACT

AS COULD BE SECURED. THE INFORMATION IS NOT WARRANTED NOR

GUARANTEED ACCURATE. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO

PROCEEDING WITH WORK.

5. ACCURATE AND LEGIBLE RECORD DRAWINGS SHALL BE MAINTAINED AT THE

JOB SITE AND BE SUBMITTED PRIOR TO FINAL PAYMENT.

6. ROOFING SYSTEMS SHALL BE PROTECTED FROM DAMAGE DURING

CONSTRUCTION ACTIVITIES.

7. TEMPORARILY PATCH ALL ROOF OPENINGS WATERTIGHT UNTIL FINAL

CLOSURE CAN BE MADE.

8. VERIFY ALL EQUIPMENT LOCATIONS AND PIPE ROUTING WITH OWNER PRIOR

TO INSTALLATION.

9. SEQUENCE OF WORK AND/OR PLACE OF COMMENCEMENT OF WORK SHALL

BE APPROVED PRIOR TO WORK BEING STARTED. SCHEDULED SHUTDOWNS

SHALL BE CLOSELY COORDINATED WITH EXISTING OPERATIONS.

FIRE PROTECTION HATCH PATTERN LEGEND:

LIGHT HAZARD: 0.10 GPM/FT^2 OVER 1,500 FT^2

ORDINARY HAZARD: 0.20 GPM/FT^2 OVER 2,500 FT^2

EXTRA HAZARD: 0.30 GPM/FT^2 OVER 2,500 FT^2

AIRCRAFT HANGAR: 12 K-25.2 HEADS @ 7 PSI

FLANGE

MAINTAIN 1' ANNULAR GAP

BETWEEN PIPE AND SLAB.

SEAL GAP

EXTERIOR WALL

FINISHED FLOOR LEVEL

GRADE

/3

78" MINIMUM

LOCATE JOINT 24" OUTSIDE OF

FOOTING PRESSURE LINE

45.00°

FOOTING PRESSURE LINE

EXTEND CASING 2" PAST

FOOTING PRESSURE LINE

(TYP)

END SEAL (TYP)

CASING

THRUST

BLOCK

SERVICE

ENTRANCE

PIPE

/3

X

/1

12"

IF DIMENSION "X" IS LESS THAN 12", INSTALL DI OR RCP CASING.

MAINTAIN AT LEAST 2" ANNULAR GAP BETWEEN PIPE AND CASING.

APPLY CASING END SEALS.

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

ISSUED

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281

/1

/2

:1 :1

A

M C

R e v it L o c a l\

.0

-P

-R

D a n .G o ld b e rg G

C S

L

.r v t

NOTES & SYMBOLS

NOT FOR CONSTRUCTION

FJRP112701ANG PRO. NO.:

3258000-131303.01

DEG

RMM

April 25, 2022

DEG

N C

A N

G

T

H A

W

C H

A R

L O

T T

E D

O U

G L A

S I A

P C

H A

R L O

T T

E N

O R

T H

C A

R O

L

IN

A

R E

P A

IR

M

A

IN

T E

N A

N C

E H

A N

G A

R B

U

IL

D

IN

G

FX001

04/25/22 B-2 RESUBMITTAL

NO SCALE1

FIRE WATER SERVICE ENTRANCE

F.E

F.E.

F.E.

F.E. F.E.

F .E

F

.E

N1N2N3N4N5N6N7N8N9

D

C

B

A

EBEA

E1

E2

E3

E4

E5

FX105

5.002

5.002

5.002

5.002

5.002

5.002

5.001

KEY PLAN

A

B

C

SHOP

SOUTH

SHOP

NORTH

B2

A2

A2

C2

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

ISSUED

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281

/1

/2

:1 :2

A

M C

R e v it L o c a l\

.0

-P

-R

D a n .G o ld b e rg G

C S

L

.r v t

FIRE PROTECTION

HANGAR DEMO PLAN

NOT FOR CONSTRUCTION

FJRP112701ANG PRO. NO.:

3258000-131303.01

DEG

RMM

April 25, 2022

DEG

N C

A N

G

T

H A

W

C H

A R

L O

T T

E D

O U

G L A

S I A

P C

H A

R L O

T T

E N

O R

T H

C A

R O

L

IN

A

R E

P A

IR

M

A

IN

T E

N A

N C

E H

A N

G A

R B

U

IL

D

IN

G

FXD101

1/16" = 1'-0"1

FIRE PROTECTION HANGER DEMO PLAN

KEYED NOTES

5.001 REMOVE ENTIRETY OF FIRE SUPPRESSION SYSTEM INCLUDING ALL

SPRINKLER HEADS, PIPING, FITTINGS, HANGERS AND APPURTENANCES.

5.002 EXISTING FOAM MONITOR NOZZLE TO BE REMOVED.

04/25/22 B-2 RESUBMITTAL

F.E.

F.E. F.E.

N1N2N3N4N5N6N7N8N9

ND

NC

NB

D

13 12 11 10 9 8

5.001 5.001

KEY PLAN

A

B

C

SHOP

SOUTH

SHOP

NORTH

B2

A2

A2

C2

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

ISSUED

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281

/1

/2

:1 :3

A

M C

R e v it L o c a l\

.0

-P

-R

D a n .G o ld b e rg G

C S

L

.r v t

FIRE PROTECTION

DEMO PLAN NORTH

WING

NOT FOR CONSTRUCTION

FJRP112701ANG PRO. NO.:

3258000-131303.01

DEG

RMM

April 25, 2022

DEG

N C

A N

G

T

H A

W

C H

A R

L O

T T

E D

O U

G L A

S I A

P C

H A

R L O

T T

E N

O R

T H

C A

R O

L

IN

A

R E

P A

IR

M

A

IN

T E

N A

N C

E H

A N

G A

R B

U

IL

D

IN

G

FXD102

1/16" = 1'-0"1

DESIGN DENSITY PLAN NORTH WING

KEYED NOTES

5.001 REMOVE ENTIRETY OF FIRE SUPPRESSION SYSTEM INCLUDING ALL

SPRINKLER HEADS, PIPING, FITTINGS, HANGERS AND APPURTENANCES.

F.E.

F.E.

F.E. F.E.

F .E

F

.E

REF.

R

EF.

R E

F

DN

DN

STAIR

STA

IR

STAIR

STAIR

N1N2N3N4N5N6N7N8N9

D

C

B

A

EBEA

E1

E2

E3

E4

E5

FX105

LOX CART

ROOM

H132

ELEC

WORK

AREA

H134

EXIT

PASSAGE

H133

ACCESSORIES

ELEMENT

CHIEF

H141

ELEC

ADMIN

H142

HYDRO

ADMIN

H144

BATTERY

ROOM

H135

BATTERY

STORAGE

H135A

HYDRO

WORK

AREA

H145

IT

H146A

HYDRO

VESTIBULE

H146

ELEC

SECTION

OFFICE

H142A

HYDRO

SECTION

CHIEF

H144A

HANGAR

H100

SPRINKLER

ROOM

H115

VESTIBULE

H113

CORRIDOR

H116

HSC

SECTION

CHIEF

H112C

OPEN

OFFICE

H112

INSPECTION

ELEMENT

CHIEF

H112B

FIRE PROTECTION GENERAL NOTES:

1. ABBREVIATIONS INDICATED HERE AND NOT USED IN THE CONTRACT

DOCUMENTS DO NOT APPLY TO THIS PROJECT. ADDITIONAL ABBREVIATIONS

MAY BE INDICATED IN THE CONTRACT DOCUMENTS.

2. THESE DRAWINGS ARE DESIGN DRAWINGS AND ARE DIAGRAMMATIC. THEY

MAY NOT SHOW ALL PHYSICAL ARRANGEMENTS, OFFSETS, BENDS, OR

ELBOWS WHICH MAY BE REQUIRED FOR INSTALLATION OF VARIOUS

MATERIALS, EQUIPMENT AND PIPING IN ALLOTTED SPACES. EXAMINE THESE

AND OTHER AVAILABLE DRAWINGS TO DETERMINE SPACE LIMITATIONS AND

INTERFERENCES. MAKE ANY MINOR CHANGES IN LOCATIONS OF EQUIPMENT

AND PIPING FROM THAT SHOWN ON DRAWINGS AND FOR ALL PHYSICAL

DETAILS REQUIRED FOR INSTALLATION. COST FOR ADAPTING WORK TO JOB

SITE CONDITIONS SHALL NOT BE CONSIDERED AS BASIS OF AN EXTRA COST

TO CONTRACT.

3. ELEVATION OF PIPING INDICATED ON THESE DRAWINGS ARE TO BE USED AS

GUIDELINES TO ASSIST WITH INSTALLATIONS. MINOR CHANGES TO THESE

ELEVATIONS MAY BE NECESSARY TO ELIMINATE UNFORESEEN

INTERFERENCES. ANY CHANGE IN ELEVATION SHALL BE APPROVED PRIOR TO

CHANGE.

4. ANY AND ALL INFORMATION SHOWN ON THESE DRAWINGS WITH RESPECT TO

EXISTING STRUCTURES, UTILITIES, AND MECHANICAL SYSTEMS IS AS EXACT

AS COULD BE SECURED. THE INFORMATION IS NOT WARRANTED NOR

GUARANTEED ACCURATE. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO

PROCEEDING WITH WORK.

5. ACCURATE AND LEGIBLE RECORD DRAWINGS SHALL BE MAINTAINED AT THE

JOB SITE AND BE SUBMITTED PRIOR TO FINAL PAYMENT.

6. ROOFING SYSTEMS SHALL BE PROTECTED FROM DAMAGE DURING

CONSTRUCTION ACTIVITIES.

7. TEMPORARILY PATCH ALL ROOF OPENINGS WATERTIGHT UNTIL FINAL

CLOSURE CAN BE MADE.

8. VERIFY ALL EQUIPMENT LOCATIONS AND PIPE ROUTING WITH OWNER PRIOR

TO INSTALLATION.

9. SEQUENCE OF WORK AND/OR PLACE OF COMMENCEMENT OF WORK SHALL

BE APPROVED PRIOR TO WORK BEING STARTED. SCHEDULED SHUTDOWNS

SHALL BE CLOSELY COORDINATED WITH EXISTING OPERATIONS.

FIRE PROTECTION HATCH PATTERN LEGEND:

LIGHT HAZARD: 0.10 GPM/FT^2 OVER 1,500 FT^2

ORDINARY HAZARD: 0.20 GPM/FT^2 OVER 2,500 FT^2

EXTRA HAZARD: 0.30 GPM/FT^2 OVER 2,500 FT^2

AIRCRAFT HANGAR: 12 K-25.2 HEADS @ 7 PSI

KEY PLAN

A

B

C

SHOP

SOUTH

SHOP

NORTH

B2

A2

A2

C2

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

ISSUED

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281

/1

/2

:1 :2

A

M C

R e v it L o c a l\

.0

-P

-R

D a n .G o ld b e rg G

C S

L

.r v t

DESIGN DENSITY

PLAN HANGAR

NOT FOR CONSTRUCTION

FJRP112701ANG PRO. NO.:

3258000-131303.01

DEG

RMM

April 25, 2022

DEG

N C

A N

G

T

H A

W

C H

A R

L O

T T

E D

O U

G L A

S I A

P C

H A

R L O

T T

E N

O R

T H

C A

R O

L

IN

A

R E

P A

IR

M

A

IN

T E

N A

N C

E H

A N

G A

R B

U

IL

D

IN

G

FX101

1/16" = 1'-0"1

DESIGN DENSITY PLAN HANGAR

F.E. F.E.

DN

N1N2N3N4N5N6N7N8N9

ND

NC

NB

D

13 12 11 10 9 8

AMXS

CHIEF

N153B

AMXS

FLIGHT

CHIEF

N153C

AMXS

FLIGHT

CHIEF

N153A

CORRIDOR

N153

COPY/PRINT

N153D

AMXS

FLIGHT

CHIEF

N153E

AMXS

FLIGHT

CHIEF

N153F

SUPPORT

EQUIPMENT

N152

FOYER

N160

CORRIDOR

N150

READY/BREAK

ROOM

N151

CTK

N131

CTK

CHECKOUT

N131A

VESTIBULE

N132

CORRIDOR

N130

COMMANDER

N141

SHIRT

OFFICE

N143

MECHANICAL

ROOM

N161

CORRIDOR

N140

JANITOR/LAUNDRY

N146

STORAGE

N145

PRO SUP

N144

MOO

N142

ENGINE

WORKROOM

N113

STORAGE

N113B

ENG

ELEMENT

CHIEF

N113A

VESTIBULE

N109

AVIONICS

ELEMENT

CHIEF

N116

CMF

CHIEF

N117

CONFERENCE

N118

PASSAGE

N115

CORRIDOR

N107

PMEL

STORAGE

N112

AVIONICS

N110

PW

OFFICE

N111

BREAK

ROOM

N122

CORRIDOR

N120

BOEING

REP

N125A

OPEN

OFFICE

N125

WOMEN

N124

MENS

N123

MENS

VESTIBULE

N121B

MENS

N121

MENS

LOCKER

N121A

MENS

SHOWER

N121C

VESTIBULE

N108

SIPR

N110A

COMSEC

N110AA

AVIONICS

STORAGE

N110B

COMM.

N103

ELEC.

ROOM

N102

VESTIBULE

N100

CORRIDOR

N101

WOMEN

N104

WOMEN

SHOWER

N104B

/1 FX102B2 FOR

PLAN OF THIS AREA

FIRE PROTECTION HATCH PATTERN LEGEND:

LIGHT HAZARD: 0.10 GPM/FT^2 OVER 1,500 FT^2

ORDINARY HAZARD: 0.20 GPM/FT^2 OVER 2,500 FT^2

EXTRA HAZARD: 0.30 GPM/FT^2 OVER 2,500 FT^2

AIRCRAFT HANGAR: 12 K-25.2 HEADS @ 7 PSI

KEY PLAN

A

B

C

SHOP

SOUTH

SHOP

NORTH

B2

A2

A2

C2

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

ISSUED

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281

/1

/2

:1 :3

A

M C

R e v it L o c a l\

.0

-P

-R

D a n .G o ld b e rg G

C S

L

.r v t

DESIGN DENSITY

NORTH WING

NOT FOR CONSTRUCTION

FJRP112701ANG PRO. NO.:

3258000-131303.01

DEG

RMM

April 25, 2022

DEG

N C

A N

G

T

H A

W

C H

A R

L O

T T

E D

O U

G…

This is the start of the file's text. The full file is on GovTribe.