PROJECT MAP:
PROJECT
LOCATION
BASE
ENTRANCE
CONSTRUCTION
ENTRANCE
BASE
OUTLINE
STATE MAP:
STATE OF NORTH CAROLINA
CITY OF CHARLOTTE,
MECKLENBURG COUNTY
VICINITY MAP:
PROJECT LOCATION
1. ROLLER SHADES IN LEU OF SLAT BLINDS
2. EPOXY FLOOR IN ROOMS:
A. HYDRO SHOP
B. WHEEL/TIRE SHOP
C. SUPPORT EQUIPMENT
D. CTK
3. ADDITIONAL PARKING SPACES
BID OPTIONS:
ANG PROJECT No.:
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281
/1
/2
:3 :5
P
M C
R e v it L o c a l\
.0
-A -R c h ri s .d o u g a n
.r v t
FJRP112701
REPAIR MAINTENANCE HANGAR BUILDING 51
CHARLOTTE DOUGLAS IAP
CHARLOTTE, NORTH CAROLINA
NCANG - 145TH AW
COVER SHEET -
VOLUME 1
FJRP112701ANG PRO. NO.:
3258000-181469.01
NJD, KB
DMD
July 20, 2022
ATM
N C
A N
G
T
H A
W
C H
A R
L O
T T
E D
O U
G L A
S I A
P C
H A
R L O
T T
E N
O R
T H
C A
R O
L
IN
A
R E
P A
IR
M
A
IN
T E
N A
N C
E H
A N
G A
R B
U
IL
D
IN
G
G-000A
VOLUME 1
07/20/22 B-3 SUBMITTAL
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281
/2
/2
:0
:1
A
M C
R e v it L o c a l\
.0
-A -R c h ri s .d o u g a n
.r v t
SHEET INDEX -
VOLUME 1
FJRP112701ANG PRO. NO.:
3258000-181469.01
NJD, KB
DMD
July 20, 2022
ATM
N C
A N
G
T
H A
W
C H
A R
L O
T T
E D
O U
G L A
S I A
P C
H A
R L O
T T
E N
O R
T H
C A
R O
L
IN
A
R E
P A
IR
M
A
IN
T E
N A
N C
E H
A N
G A
R B
U
IL
D
IN
G
G-001A
SHEET INDEX - VOLUME 2
A-515 PLAN DETAILS INTERIOR - MINOR CONSTRUCTION
A-601 DOOR AND FRAME SCHEDULES AND LEGENDS - EXIST & AREA A
A-602 DOOR AND FRAME SCHEDULES AND LEGENDS - AREAS B & C
A-603 WINDOW TYPES & DETAILS
A-605 TRANSLUCENT PANEL DETAILS
A-621 DOOR DETAILS-INTERIOR AND EXTERIOR
A-700 FINISH SCHEDULES
A-701A FINISH PLAN - AREA A
A-701A2 FINISH PLANS - AREA A2
A-701B FINISH PLAN - AREA B
A-701B2 FINISH PLAN - MINOR CONSTRUCTION AREA B2
A-701C FINISH PLAN-AREA C
A-702A HANGAR BAY STRIPING PLAN
A-703 FINISH DETAILS
A-801A SIGNAGE PLAN - AREA A
A-801A2 SIGNAGE PLANS - AREA A2
A-801B SIGNAGE PLAN - AREA B
A-801B2 SIGNAGE PLAN - MINOR CONSTRUCTION AREA B2
A-801C SIGNAGE PLAN - AREA C
A-804 SIGNAGE PLAN - LOWER CATWALK
A-805 SIGNAGE PLAN - UPPER CATWALK
A-851 SIGNAGE DETAILS
A-852 SIGNAGE SCHEDULE
A-901A2 FIXTURES, FURNITURE AND EQUIPMENT PLANS - AREA A2
A-901B FIXTURES, FURNITURE AND EQUIPMENT PLAN - AREA B
A-901C FIXTURES, FURNITURE AND EQUIPMENT PLAN - AREA C
Sheets in Volume: 135
SHEET INDEX - VOLUME 2
GENERAL
G-001B SHEET INDEX - VOLUME 2
ARCHITECTURAL
A-001 NOTES & SYMBOLS
A-002 PARTITION TYPES
A-003 PARTITION DETAILS & TOILET ACCESSORY MOUNTING HEIGHTS
A-004 ASSEMBLIES
A-005 ARCHITECTURAL KEYNOTES
AD100 DEMOLITION OVERALL PLAN
AD101A DEMOLITION FLOOR PLAN - AREA A
AD101B DEMOLITION FLOOR PLAN - AREA B
AD101C DEMOLITION FLOOR PLAN - AREA C
AD101C2 DEMOLITION FLOOR PLAN - MINOR CONSTRUCTION AREA C2
AD102A DEMOLITION MEZZANINE PLAN - AREA A
AD102A2 DEMOLITION MEZZANINE PLANS - AREA A2
AD105A DEMOLITION ROOF PLAN - AREA A
AD105B DEMOLITION ROOF PLAN - AREA B
AD105C DEMOLITION ROOF PLAN - AREA C
AD105C2 DEMOLITION ROOF PLAN - MINOR CONSTRUCTION AREA C2
AD121A DEMOLITION REFLECTED CEILING PLAN - AREA A
AD121B DEMOLITION REFLECTED CEILING PLAN - AREA B
AD121C DEMOLITION REFLECTED CEILING PLAN - AREA C
AD201 DEMOLITION EXTERIOR ELEVATIONS - AREA A
AD202 DEMOLITION EXTERIOR ELEVATIONS - AREA A
AD203 DEMOLITION EXTERIOR ELEVATIONS - AREA B
AD204 DEMOLITION EXTERIOR ELEVATIONS AREA C
AD205 DEMOLITION EXTERIOR ELEVATIONS - MINOR CONSTRUCTION
AD206 DEMOLITION EXTERIOR ELEVATIONS - AREA C2
AD301 DEMOLITION SECTIONS
A-100 OVERALL PLAN
A-101A FIRST FLOOR PLAN - AREA A
A-101A2 FIRST FLOOR PLANS - AREA A2
A-101B FIRST FLOOR PLAN - AREA B
A-101B2 FIRST FLOOR PLAN - MINOR CONSTRUCTION AREA B2
A-101C FIRST FLOOR PLAN - AREA C
A-101C2 FIRST FLOOR PLAN - MINOR CONSTRUCTION AREA C2
A-102 MEZZANINE PLAN - OVERALL
A-102A2 MEZZANINE PLANS - AREA A2
A-102A3 MEZZANINE ISOMETRICS - AREA A2
A-102B2 CLERESTORY FLOOR PLAN - MINOR CONSTRUCTION AREA B2
A-103 LOWER CATWALK PLAN
A-104 UPPER CATWALK PLAN
A-105 ROOF PLAN - OVERALL
A-105A ROOF PLAN - AREA A
A-105B ROOF PLAN - AREA B
A-105B2 ROOF PLAN - MINOR CONSTRUCTION AREA B2
A-105C ROOF PLAN - AREA C
A-105C2 ROOF PLAN - MINOR CONSTRUCTION AREA C2
A-121A REFLECTED CEILING PLAN - AREA A
A-121A2 REFLECTED CEILING PLANS - AREA A2
A-121B REFLECTED CEILING PLAN - AREA B
A-121B2 REFLECTED CEILING PLAN - MINOR CONSTRUCTION AREA B2
A-121C REFLECTED CEILING PLAN - AREA C
A-121C2 REFLECTED CEILING PLAN - MINOR CONSTRUCTION AREA C2
A-122B ENLARGED CEILING PLANS - AREAS B & C
A-151A2 FIRST FLOOR AIR BARRIER PLANS - AREA A2
A-151B FIRST FLOOR AIR BARRIER PLAN - AREA B
A-151B2 FIRST FLOOR AIR BARRIER PLAN - MINOR CONSTRUCTION AREA B2
A-151C FIRST FLOOR AIR BARRIER PLAN - AREA C
A-152B2 CLERESTORY AIR BARRIER PLAN - MINOR CONSTRUCTION AREA B2
A-152C2 CLERESTORY AIR BARRIER PLAN - MINOR CONSTRUCTION AREA C2
A-201 EXTERIOR ELEVATIONS - AREA A
A-202 EXTERIOR ELEVATIONS - AREA A
A-203 EXTERIOR ELEVATIONS - AREA B
A-204 EXTERIOR ELEVATIONS - MINOR CONSTRUCTION AREA B2
A-205 EXTERIOR ELEVATIONS - AREA C
A-206 EXTERIOR ELEVATIONS - MINOR CONSTRUCTION AREA C2
A-207 EXTERIOR FACADE REPAIR ELEVATIONS - AREA A
A-208 EXTERIOR FACADE REPAIR ELEVATIONS - AREAS B & C
A-301 BUILDING SECTIONS - AREA A
A-302 BUILDING SECTIONS - AREA A2
A-303 BUILDING SECTIONS - AREA B
A-304 BUILDING SECTIONS - MINOR CONSTRUCTION AREA B2
A-305 BUILDING SECTIONS - MINOR CONSTRUCTION AREA C2
A-310 WALL SECTIONS - AREA A
A-311 WALL SECTIONS - AREA A2 SOUTH HANGAR SHOP
A-312 WALL SECTIONS - AREA A2 NORTH HANGAR SHOP
A-313 WALL SECTIONS - AREA B
A-314 WALL SECTIONS - AREA B
A-315 WALL SECTIONS - MINOR CONSTRUCTION AREA B2
A-316 WALL SECTIONS - AREAS B & B2
A-317 WALL SECTIONS - MINOR CONSTRUCTION AREA B2
A-318 WALL SECTIONS - AREAS B & C
A-319 WALL SECTIONS - AREA C
A-320 WALL SECTIONS - MINOR CONSTRUCTION AREA C2
A-321 WALL SECTIONS - AREA B & C AIR BARRIER
A-322 WALL SECTIONS - HANGAR SHOP AIR BARRIERS
A-400 ENLARGED PLANS AND INTERIOR ELEVATIONS - AREA A
A-401 INTERIOR ELEVATIONS - AREA A
A-402 ENLARGED PLANS AND INTERIOR ELEVATIONS - AREA B
A-403 ENLARGED PLANS AND INTERIOR ELEVATIONS - AREA B
A-404 ENLARGED PLANS AND INTERIOR ELEVATIONS - AREA C
A-405 INTERIOR ELEVATIONS - AREA C
A-406 CASEWORK DETAILS
A-410 RAILING TYPES
A-411 ENLARGED STAIR AND SHIPS LADDER PLANS & SECTIONS - AREA B, B2 &
HANGAR SHOP SOUTH
A-412 ENLARGED STAIR AND SHIPS LADDER PLANS & SECTIONS - HANGAR SHOP
NORTH
A-501 ROOF DETAILS
A-502 SECTION DETAILS EXTERIOR
A-503 SECTION DETAILS - AREA A
A-504 SECTION DETAILS EXTERIOR - MINOR CONSTRUCTION AREA B2
A-505 SECTION DETAILS EXTERIOR - MINOR CONSTRUCTION AREA B2
A-506 SECTION DETAILS - MINOR CONSTRUCTION AREA C2
A-507 SECTION DETAILS - MINOR CONSTRUCTION AREA C2
A-508 SECTION DETAILS - INTERIOR
A-509 PLAN DETAILS - AIR BARRIER
A-510 SECTION DETAILS - AIR BARRIER
A-511 PLAN DETAILS EXTERIOR - MINOR CONSTRUCTION AREAS B & B2
A-512 PLAN DETAILS - MINOR CONSTRUCTION AREA B2
A-513 PLAN DETAILS EXTERIOR - MINOR CONSTRUCTION AREA C2
A-514 PLAN DETAILS INTERIOR - AREAS A, B & C
SHEET INDEX - VOLUME 1
GENERAL
G-001A SHEET INDEX - VOLUME 1
G-003 CODE ANALYSIS
G-004A ROOM OCCUPANCY CLASSIFICATIONS
G-004B OCCUPANCY PLANS
G-005A LIFE SAFETY PLAN - AREA A
G-005A2 LIFE SAFETY PLANS - AREA A2
G-005B LIFE SAFETY PLANS - AREA B & C
G-006A LIFE SAFETY PLAN - LOW CATWALK
G-007A LIFE SAFETY PLAN - UPPER CATWALK
CIVIL
C100 CIVIL LEGEND AND ABBREVIATIONS
VF101 EXISTING CONDITIONS
GC121 SURVEY CONTROL PLAN
GC141 CONSTRUCTION ACCESS & LOCATION PLAN
GC145 CONSTRUCTION OPERATION PLAN NOTES
BB101 PLAN & LOG OF SOIL BORINGS
EC101 EROSION CONTROL PLAN
EC501 EROSION CONTROL DETAILS
CD101 DEMOLITION PLAN
CS111 SITE PLAN
CS121 ENLARGED SITE AND PAVING PLAN - AREAS 1 & 2
CS122 ENLARGED SITE AND PAVING PLAN - AREA 3
CS501 SITE DETAILS
CS502 SITE DETAILS
CS503 SITE DETAILS
CS504 SITE DETAILS
CG121 ENLARGED GRADING & DRAINAGE PLAN - AREAS 1 & 2
CG122 ENLARGED GRADING & DRAINAGE PLAN - AREA 3
CU101 ENLARED UTILITY PLAN - AREA 3
CU501 UTILITY DETAILS
CU502 UTILITY DETAILS
STRUCTURAL
S-001 NOTES, SYMBOLS, AND ABBREVIATIONS
S-002 NOTES, SYMBOLS, AND ABBREVIATIONS
S-005 STATEMENT OF SPECIAL INSPECTIONS
S-006 STRUCTURAL STEEL SPECIAL INSPECTIONS
S-007 MASONRY AND STEEL DECK SPECIAL INSPECTIONS
S-008 STRUCTURAL PROJECT KEYNOTES
S-010 ROOF LOADING PLAN
S-052A EXISTING BOTTOM CHORD FRAMING PLAN - AREA A
S-053A EXISTING ROOF FRAMING PLAN - AREA A
SD101A FOUNDATION AND FLATWORK DEMOLITION PLAN - AREA A
SD101B FOUNDATION AND FLATWORK DEMOLITION PLAN - AREA B
SD101C FOUNDATION AND FLATWORK DEMOLITION PLAN - AREA C
SD101C2 FOUNDATION AND FLATWORK DEMOLITION PLAN - MINOR
CONSTRUCTION - AREA C2
SD131B STRUCTURAL DEMOLITION FLOOR PLAN - AREA B
SD131C STRUCTURAL DEMOLITION FLOOR PLAN - AREA C
SD152A BOTTOM CHORD FRAMING DEMOLITION PLAN - AREA A
S-101A FOUNDATION PLAN - AREA A
S-101A2 FOUNDATION PLANS - AREA A2
S-101B FOUNDATION PLAN - AREA B
S-101B2 FOUNDATION PLAN - MINOR CONSTRUCTION - AREA B2
S-101C FOUNDATION PLAN - AREA C
S-101C2 FOUNDATION PLAN - MINOR CONSTRUCTION - AREA C2
S-111A FLATWORK PLAN - AREA A
S-111A2 FLATWORK PLANS - AREA A2
S-111B FLATWORK PLAN - AREA B
S-111B2 FLATWORK PLAN - MINOR CONSTRUCTION - AREA B2
S-111C FLATWORK PLAN - AREA C
S-111C2 FLATWORK PLAN - MINOR CONSTRUCTION - AREA C2
S-131A STRUCTURAL FLOOR PLAN - AREA A
S-131A2 STRUCTURAL FLOOR PLANS - AREA A2
S-131B STRUCTURAL FLOOR PLAN - AREA B
S-131B2 STRUCTURAL FLOOR PLAN - MINOR CONSTRUCTION - AREA
B2
S-131C STRUCTURAL FLOOR PLAN - AREA C
S-142A MEZZANINE FRAMING PLAN - AREA A
S-142A2 MEZZANINE FRAMING PLANS - AREA A2
S-151B ROOF FRAMING PLAN - AREA B
S-151C ROOF FRAMING PLAN - AREA C
S-151C2 ROOF FRAMING PLAN - MINOR CONSTRUCTION - AREA C2
S-152A BOTTOM CHORD FRAMING PLAN - AREA A
S-153A ROOF FRAMING PLAN - AREA A
S-153B2 HIGH ROOF FRAMING PLAN - MINOR CONSTRUCTION - AREA
B2
S-153C2 HIGH ROOF FRAMING PLAN - MINOR CONSTRUCTION - AREA
C2
S-301 SECTIONS
S-411 ENLARGED FLATWORK PLANS
S-431 ENLARGED STRUCTURAL FLOOR PLANS
S-441 ENLARGED FRAMING PLAN AND DETAILS
S-501 FOUNDATION DETAILS
S-502 FOUNDATION DETAILS
S-511 FLATWORK DETAILS
S-512 FLATWORK DETAILS
S-521 WALL DETAILS
S-522 WALL DETAILS
S-541 FRAMING DETAILS
S-542 FRAMING DETAILS
S-543 FRAMING DETAILS
S-544 FRAMING DETAILS
S-545 FRAMING DETAILS
S-551 FRAMING DETAILS
S-552 FRAMING DETAILS
S-601 STRUCTURAL SCHEDULES
Sheets in Volume: 90
SHEET INDEX - VOLUME 3
GENERAL
G-001C SHEET INDEX - VOLUME 3
FIRE ALARM
FA001 NOTES & SYMBOLS
FAD101 FIRE ALARM OVERALL DEMO PLAN
FA102 FIRE ALARM AND MNS FLOOR PLAN HANGAR
FA103 FIRE ALARM AND MNS FLOOR PLAN NORTH WING
FA104 FIRE ALARM AND MNS ENLARGED FLOOR PLAN EAST WING
FA105 FIRE ALARM AND MNS RISER DIAGRAM AND MATRIX
FIRE PROTECTION
FX001 NOTES & SYMBOLS
FXD101 FIRE PROTECTION HANGAR DEMO PLAN
FXD102 FIRE PROTECTION DEMO PLAN NORTH WING
FX101 DESIGN DENSITY PLAN HANGAR
FX102 DESIGN DENSITY NORTH WING
FX102B2 DESIGN DENSITY PLAN - AREA B2 - MINOR CONSTRUCTION
FX103 FIRE PROTECTION HANGAR FLOOR PLAN
FX104 FIRE PROTECTION FIRE PUMP ROOM
FX105 FIRE PROTECTION SPRINKLER ROOM
PLUMBING
P-001 PLUMBING NOTES & SYMBOLS
PD100B UNDERGROUND DRAIN AND VENT DEMO PLUMBING PLAN - AREA B
PD100C UNDERGROUND DRAIN AND VENT DEMO PLUMBING PLAN - AREA C
PD101A ABOVEGROUD DRAIN AND VENT DEMO PLUMBING PLAN - AREA A
PD101B ABOVEGROUND DRAIN AND VENT DEMO PLUMBING PLAN - AREA B
PD101C ABOVEGROUND DRAIN AND VENT DEMO PLUMBING PLAN - AREA C
PD102A ROOF - DRAIN AND VENT DEMO PLUMBING PLAN - AREA A
PD102B ROOF - DRAIN AND VENT DEMO PLUMBING PLAN - AREA B
PD102C ROOF - DRAIN AND VENT DEMO PLUMBING PLAN - AREA C
PD131A SUPPLY DEMO PLUMBING PLAN - AREA A
PD131B SUPPLY DEMO PLUMBING PLAN - AREA B
PD131C SUPPLY DEMO PLUMBING PLAN - AREA C
P-100A2 UNDERGROUND DRAIN AND VENT PLUMBING PLAN - HANGAR SHOPS
P-100B UNDERGROUND DRAIN AND VENT PLUMBING PLAN - AREA B
P-100B2 UNDERGROUND DRAIN AND VENT PLUMBING PLAN - AREA B2
P-100C UNDERGROUND DRAIN AND VENT PLUMBING PLAN - AREA C
P-101A DRAIN AND VENT PLUMBING PLAN - AREA A
P-101A2 DRAIN AND VENT PLUMBING PLAN - HANGAR SHOPS
P-101B DRAIN AND VENT PLUMBING PLAN - AREA B
P-101B2 DRAIN AND VENT PLUMBING PLAN - AREA B2
P-101C DRAIN AND VENT PLUMBING PLAN - AREA C
P-102A ROOF - DRAIN AND VENT PLUMBING PLAN - AREA A
P-102B ROOF - DRAIN AND VENT PLUMBING PLAN - AREA B
P-102B2 ROOF - DRAIN AND VENT PLUMBING PLAN - AREA B2
P-102C ROOF - DRAIN AND VENT PLUMBING PLAN - AREA C
P-131A SUPPLY PLUMBING PLAN - AREA A
P-131A2 SUPPLY PLUMBING PLANS - HANGAR SHOPS
P-131B SUPPLY PLUMBING PLAN - AREA B
P-131C SUPPLY PLUMBING PLAN - AREA C
P-501 PLUMBING DETAILS
P-502 PLUMBING DETAILS
P-601 PLUMBING SCHEDULES
P-602 PLUMBING SCHEDULES
P-901 DRAIN AND VENT ISOMETRIC PLUMBING DIAGRAM
P-931 SUPPLY ISOMETRIC PLUMBING PLAN
MECHANICAL
M-001 MECHANICAL NOTES & SYMBOLS
MD101A HVAC DEMOLITION FLOOR PLAN - AREA A
MD101B HVAC DEMOLITION FLOOR PLAN - AREA B
MD101C HVAC DEMOLITION FLOOR AND ROOF PLAN - AREA C
MD105A HVAC DEMOLITION ROOF PLAN - AREA A
MD105B HVAC DEMOLITION ROOF PLAN - AREA B
MD131A MECHANICAL PIPING DEMOLITION FLOOR PLAN - AREA A
MD131B MECHANICAL PIPING DEMOLITION FLOOR PLAN - AREA B
MD131C MECHANICAL PIPING DEMOLITION FLOOR PLAN - AREA C
MD401 ENLARGED DEMOLITION PLANS - AREA B AND AREA C
M-101A HVAC FLOOR PLAN - AREA A
M-101A2 HVAC FIRST FLOOR PLAN - AREA A2
M-101B HVAC FLOOR PLAN - AREA B
M-101B2 HVAC FLOOR PLAN - MINOR CONSTRUCTION AREA B2
M-101C HVAC FLOOR AND ROOF PLAN - AREA C
M-102A2 HVAC MEZZANINE PLANS - AREA A2
M-105A HVAC ROOF PLAN - AREA A
M-105B HVAC ROOF PLAN - AREA B
M-131A MECHANICAL PIPING FLOOR PLAN - AREA A
M-131A2 MECHANICAL FIRST FLOOR PLAN - AREA A2
M-131B MECHANICAL PIPING FLOOR PLAN - AREA B
M-131B2 MECHANICAL FLOOR PLAN - MINOR CONSTRUCTION AREA B2
M-131C MECHANICAL PIPING FLOOR PLAN - AREA C
M-132A2 MECHANICAL MEZZANINE PLANS - AREA A2
M-401 ENLARGED PLANS - AREA B, AREA C AND AREA D
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-503 MECHANICAL DETAILS
M-504 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
M-602 MECHANICAL SCHEDULES
M-603 MECHANICAL SCHEDULES
M-604 MECHANICAL SCHEDULES
M-605 MECHANICAL SCHEDULES
M-606 MECHANICAL SCHEDULES
M-607 MECHANICAL SCHEDULES
M-608 MECHANICAL SCHEDULES
M-609 MECHANICAL SCHEDULES
M-711 MECHANICAL SCHEMATICS
M-712 MECHANICAL SCHEMATICS
M-801 MECHANICAL CONTROL SCHEMATICS
M-802 MECHANICAL CONTROL SCHEMATICS
M-803 MECHANICAL CONTROL SCHEMATICS
M-804 MECHANICAL CONTROL SCHEMATICS
M-805 MECHANICAL CONTROL SCHEMATICS
Sheets in Volume: 96
SHEET INDEX - VOLUME 4
GENERAL
G-001D SHEET INDEX - VOLUME 4
ELECTRICAL
E-001 NOTES, SYMBOLS & ABBREVIATIONS
ED101A FIRST FLOOR ELECTRICAL DEMOLITON PLAN - AREA A
ED101B FIRST FLOOR ELECTRICAL DEMOLITON PLAN - AREA B
ED101C FIRST FLOOR & ROOF ELECTRICAL DEMOLITION PLAN - AREA C
ED102A MEZZANINE FLOOR & CATWALK LEVEL ELECTRICAL DEMOLITION PLAN - AREA A
ED102B ROOF ELECTRICAL & LIGHTNING PROTECTION DEMOLITION PLAN - AREA B
ED103A ROOF ELECTRICAL & LIGHTNING PROTECTION DEMOLITION PLAN - AREA A
ED701 DEMOLITION ONE-LINE DIAGRAM
E-100A HAZARDOUS AREA CLASSIFICATION PLAN
E-101A FIRST FLOOR POWER PLAN - AREA A
E-101A2 FIRST FLOOR POWER PLAN - AREA A2
E-101B FIRST FLOOR POWER PLAN - AREA B
E-101B2 FIRST FLOOR POWER PLAN - MINOR CONSTRUCTION - AREA B2
E-101C FIRST FLOOR & ROOF POWER PLAN - AREA C
E-102A MEZZANINE FLOOR & CATWALK LEVEL POWER PLAN - AREA A
E-103A ROOF POWER & LIGHTNING PROTECTION PLAN - AREA A
E-103B ROOF POWER & LIGHTNING PROTECTION PLAN - AREA B
E-103B2 ROOF POWER & LPS PLAN - MINOR CONSTRUCTION - AREA B2
E-121A FIRST FLOOR LIGHTING PLAN - AREA A
E-121A2 FIRST FLOOR LIGHTING PLAN - AREA A2
E-121B FIRST FLOOR LIGHTING PLAN - AREA B
E-121B2 FIRST FLOOR LIGHTING PLAN - MINOR CONSTRUCTION - AREA B2
E-121C FIRST FLOOR LIGHTING PLAN - AREA C
E-122A MEZZANINE FLOOR & CATWALK LEVEL LIGHTING PLAN - AREA A
E-401 ENLARGED POWER & DEMOLITION PLANS
E-402 ENLARGED POWER PLANS
E-403 ENLARGED PLANS
E-404 ENLARGED PHOTOS
E-405 ENLARGED PHOTOS
E-501 ELECTRICAL DETAILS
E-502 ELECTRICAL DETAILS
E-601 LUMINAIRE SCHEDULES
E-602 LIGHTING CONTROL SCHEDULES & CONTROLS NARRATIVE
E-603 EQUIPMENT WIRING SCHEDULES
E-604 EQUIPMENT WIRING SCHEDULES
E-605 PANEL SCHEDULES
E-606 PANEL SCHEDULES
E-607 PANEL SCHEDULES
E-608 PANEL SCHEDULES
E-701 ONE-LINE DIAGRAM
E-702 ONE-LINE DIAGRAM
TECHNOLOGY SYSTEMS
T-001 NOTES, SYMBOLS & ABBREVIATIONS
TD101A FIRST FLOOR TECHNOLOGY DEMOLITION PLAN - AREA A - HANGAR
TD101B FIRST FLOOR TECHNOLOGY DEMOLITION PLAN - AREA B - NORTH WING
TD101C FIRST FLOOR & ROOF TECHNOLOGY DEMOLITION PLAN - AREA C - EAST WING
TD102A MEZZANINE FLOOR & CATWALK LEVEL TECHNOLOGY DEMOLITION PLAN - AREA A - HANGAR
TD103A ROOF TECHNOLOGY DEMOLITION PLAN - AREA A - HANGAR
T-100 TECHNOLOGY SITE PLAN
T-101A FIRST FLOOR - AREA A - TECHNOLOGY SYSTEMS
T-101A2 HANGAR SHOP - AREA A2 - TECHNOLOGY SYSTEMS
T-101B FIRST FLOOR - AREA B - TECHNOLOGY SYSTEMS
T-101B2 FIRST FLOOR - AREA B2 - TECHNOLOGY SYSTEMS
T-101C FIRST FLOOR - AREA C - TECHNOLOGY SYSTEMS
T-102 MEZZANINE PLANS - TECHNOLOGY SYSTEMS
T-103A ROOF TECHNOLOGY PLAN - AREA A
T-121A FIRST FLOOR - AREA A - SECURITY
T-121A2 HANGAR SHOP - AREA A2 - SECURITY SYSTEMS
T-121B FIRST FLOOR - AREA B - SECURITY
T-121B2 FIRST FLOOR - AREA B2 - SECURITY
T-121C FIRST FLOOR - AREA C - SECURITY
T-123A ROOF SECURITY PLAN - AREA A
T-401 ENLARGED PLANS
T-402 ENLARGED PLANS
T-403 ENLARGED PLANS
T-404 ENLARGED PLANS
T-405 ENLARGED PLANS
T-501 DETAILS
T-502 DETAILS
T-503 DETAILS
T-701 ONE-LINE DIAGRAMS
Sheets in Volume: 71
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281
/1
/2
:3 :1
P
M C
R e v it L o c a l\
.0
-A -R c h ri s .d o u g a n
.r v t
CODE ANALYSIS
FJRP112701ANG PRO. NO.:
3258000-181469.01
KB
DMD
July 20, 2022
ATM
N C
A N
G
T
H A
W
C H
A R
L O
T T
E D
O U
G L A
S I A
P C
H A
R L O
T T
E N
O R
T H
C A
R O
L
IN
A
R E
P A
IR
M
A
IN
T E
N A
N C
E H
A N
G A
R B
U
IL
D
IN
G
G-003
ASHRAE Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings – 2013
ASHRAE Standard 62.1: Ventilation for Acceptable Indoor Air Quality - 2013
ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy - 2013
NFPA 914: Code for Fire Protection of Historic Structures - 2019
NFPA 780: Standard for the Installation of Lightning Protection Systems - 2020
NFPA 409: Standards On Aircraft Hangars - 2016 UFC 4-211-01: 1-hr separation between hangar and other building areas
Fire-Resistance Rating Requirements for Hazard Separation
NFPA 285: Standard Fire Test Method for Evalution of Fire Propagation Charcteristics of Exterior...
NFPA 170: Standard for Fire Safety and Emergency Symbols - 2018 of 01. W/cm²
NFPA 101: Life Safety Code - 2018 Interior Floor Finish: Floor coverings other than carpet shall have a minimum critical radiant flux
NFPA 90A: Standard for the Installation of Air Conditioning and Ventilating Systems - 2018 Interior Floor Finish: Carpet and carpet like interior floor finishes shall comply with ASTM D-2859
NFPA 75: Standard for Fire Protection of Information Technology Equipment - 2020 Interior Floor Finish in Exit Enclosures: Class II (Minimum)
NFPA 72: National Fire Alarm Code and Signaling Code - 2019 Interior Wall and Ceiling Finish for other areas: Class B (Minimum)
NFPA 70: National Electrical Code - 2020 Interior Wall and Ceiling Finish for Exits and Exit Corridors: Class A (Minimum)
NFPA 58: Liquefied Petroleum Gas Code - 2020 NFPA 101, Section 38.3.3 including subsections and Section 10.2 including subsections
NFPA 54 (ANSI Z223.1): National Fuel Gas Code - 2018 Interior Finishes:
NFPA 24: Standard for the Installation of Private Service Mains and Their Appurtenances - 2019 X ≥ 30 ft 0 hr Service Sinks 1 1
NFPA 13: Standard for the Installation of Sprinkler Systems - 2019 10 ft ≤ 30 ft 0 hr Drinking Fountains 7 3
NFPA 10: Standards for Portable Fire Extinguishers - 2018 5 ft ≤ 10 ft 1 hr Showers 0 5
NFPA 1: Fire Code - 2021 X < 5 ft 1 hr Lavatories 14 17
Group B, Type IIB Construction Water Closets 15 20
International Code Council (ICC) Library of Codes - 2018 Exterior Nonbearing Walls and Partitions where "x" is distance from fire separation Required Provided
IBC Table 602
Public Codes: Fire-Resistance Rating Requirements for Exterior Walls Based on Fire Separation Distance Service Sinks: 1 per floor
Drinking Fountains: 1 per 75 persons (p)
ANG-ETL 11-12, Compliance with Handicapped Accessibility Standards Roof Construction 0 hr Showers - both male and female: 1 per 15 persons (p), only if need
ANG-ETL 10-3, Air National Guard Design Objectives and Procedures Floor Construction 0 hr Lavatories - both male and female: 1 per 20 persons (p), up to 100 p ; then 1 per 45 p
● Applicable current ANG-ETL's as listed in ANG-ETL 15-01 Interior 0 hr
ANG-ETL 15-01, Air National Guard Design Policy - May 1, 2015 All references to NFPA 70 muste be considered to be references to UFC 3-501-01, which cites
NFPA 70.
Nonbearing walls and Partitions Urinals - male: Urinals may be substituted for no more than one-third of the water closets required, one for one.
Electrical Code: Exterior 0 hr
Air National Guard Engineering Technical Letters (ANG-ETL) Nonbearing walls and Partitions Water Closets - both male and female: 1 per 20 persons (p), up to 100 p ; then 1 per 40 p
Interior 0 hr Business Occupancy
Air National Guard Design Requirements: All references to the International Mechanical Code (IMC) must be considered to be references to UFC 3-410-01, which cites the IMC.
Exterior 0 hr Minimum Number of Plumbing Fixtures
Mechanical Code: Bearing Walls UFC 3-420-01, Section 402.1.D
Accessibility: Architectural Barriers Act (ABA) Standards (2015) Primary structural frame 0 hr Plumbing Fixtures:
Energy Conservation: Public Law 1095-58; Energy Policy Act (EPAct of 2005), - August 8, 2005 Type IIB Construction
All references to the International Energy Conservation Code (IECC) must be considered to be references to UFC 1-200-02, which cites ASHRAE 90.1 and ASHRAE 189.1.
IBC Table 601
Public Law: Energy Code: Fire-Resistance Rating Requirements for Building Elements (Hours) The design and construction of this facility shall comply with ABA Accessible Standards for Department of Defense Facilities as adopted by the Deputy Secretary of Defense Memorandum dated October 31, 2008 (Revised 2015).
UFC 4-211-01: Aircraft Maintenance Hangars - Change 2, 15 May 2020 Hangar Building 70,000 66,978 ABA Accessibility Standard for Department of Defense Facilities
UFC 4-021-01: Design and O&M: Mass Notification Systems - Change 1, January 2010 All references to the International Plumbing Code (IPC) must be considered to be referrenes to UFC 3-410-01, which cites the IPC.
Accessibility Requirements:
UFC 4-010-02: DoD Minimum Antiterrorism Standards for Buildings (FOUO) - February 9, 2012 Plumbing Code:
Allowable Area (S.F.)
Actual Area (S.F.)
UFC 4-010-01: DoD Minimum Antiterrorism Standards for Buildings - Change 1, 19 Aug 2020
UFC 3-600-01: Fire Protection Engineering for Facilities - Change 5, 24 Sep 2020 NFPA 54 (ANSI Z223.1) and NFPA 58. Hangar - Group S1 / IIB = 70,000 s.f.
UFC 3-580-01: Telecommunications Building Cabling Systems Planning and Design - Change 1, June 1, 2016 All references to the Internatinal Fuel Gas Code (IFGC) must be considered to be references to IBC Table 506.2:
UFC 3-575-01: Lightning and Static Electricity Protection Systems - July 1, 2012 Fuel Gas Code: Building Area: Portable fire extinguishers shall be selected, installed, inspected, and maintained in accordance with NFPA 10.
The local Authority Having Jurisdiction (AHJ) shall coordinate the (1) size, (2) type, and (3) location of portable fire extinguishers for each room in the facility.
UFC 3-560-01: Electrical Safety, O&M - Change 2, 31 Oct 2019 NFPA 101, Section 9.7.4.1
UFC 3-550-01: Exterior Electrical Power Distribution - Change 3, 01 Nov 2019 UFC-3-600-01, which cites NFPA 1. Actual 1 Stories Fire Extinguishers, General:
UFC 3-530-01: Interior and Exterior Lighting Systems and Controls - Change 4, 1 Nov 2019 All references to the International Fire Code (IFC) must be considered to be references to Maximum Allowed 1 Stories Aircraft Hangar(S-1), Sprinklered 250 feet
UFC 3-520-01: Interior Electrical Systems - Change 1, 20 Mar 2019 Fire Code: Group S1 Number of Stories New Business Occupancies 300 feet
UFC 3-501-01: Electrical Engineering - Change 1, 01 Nov 2019 Actual 1 Stories NFPA 101, Section 38.2.6.3
UFC 3-430-01FA: Heating and Cooling Distribution Systems - July 25, 2003 Maximum Allowed 4 Stories Travel Distance to Exits:
UFC 3-420-02FA: Compressed Air - Change 1, December, 2007 Group B Number of Stories New Business Occupancies 100 feet
UFC 3-420-01: Plumbing Systems - Change 11, 1 Nov 2019 NFPA 101, Section 38.2.5.3.1
UFC 3-410-01: Heating, Ventilating, and Air Conditioning - Change 6, 20 Mar 2020 ICC - International Existing Building Code (IEBC) as modified by Chapter 2, 3, and 4 of UFC 1-200-01 through reference to core UFC, other UFC as identified in Appendix A, References, and other listed miltiary criteria in UFC 1-200-01. In conflicts between the IEBC and military criteria use the military criteria.
Group B / IIB = 4 Stories Common Path of Travel:
UFC 3-401-01: Mechanical Engineering - Change 1, October, 2015 Existing Structure: IBC Table 504.4: New Business Occupancies 50 feet
UFC 3-400-02: Design: Engineering Weather Data - 20 Sep 2018 Allowable Number of Stories Above Grade Plane NFPA 101, Section 38.2.5.2.1
UFC 3-310-04: Seismic Design of Buildings - Change 1, June 20, 2016 Dead-end Corridor Distance:
UFC 3-301-01: Structural Engineering - 01 Oct 2019
UFC 3-240-01: Waste Water Collection - Change 1, 01 Aug 2020 Total Occupants: 434
UFC 3-230-01: Water Storage, Distribution, and Transmission - Change 1, 1 Oct 2018 Hangar 45,538 121
UFC 3-220-01: Geotechnical Engineering - November 1, 2012 Use IBC Chapter 16, Structural Design as modified by UFC 3-3010-01. Use IBC Chapter 16 and UFC 3-310-04 for the sesmic design of buildings. IBC Chapter 16 describes minimal structural loading requirements, minimum design loads (live and dead load, snow and as well as load combinations, and permitted design methodoologies.wind, rain, flood, and earthquake), The building height of one-story aircraft hangars, aircraft paint hangars and buildings used for the manufacturing of aircraft shall not be limited where the building is provided with an automatic sprinkler system or automatic fire-extinguishing system in accordance with Chapter 9 and is entirely surrounded by public ways or yards not less in width than one and one-half times the building height .
North Wing 18,081 223
UFC 3-210-10: Low Impact Development - Change 3, 01 Mar 2020 Chapter 16 - Structural Design IBC Section 504.1, Exception 95 Feet East Wing 3,359 90
UFC 3-201-02: Landscape Architecture - 29 April 2020 Actual 15 Feet Floor Level Area Occupants
UFC 3-201-01: Civil Engineering - Change 4, 28 Sep 2020 Maximum Allowed 75 Feet
UFC 3-120-10: Interior Design - 16 May 2018
Group B
Building Height
UFC 3-110-03: Roofing - Change 5, 12 June 2020 All references twithin the IBC to Chapter 11, Accessibility must be considered be references to the Architectrual Barriers Act (ABA) Standards (2015). Do notu use IBC, Chapter 11 for determining accessibility.
NFPA 101, Table 7.3.1.2 Occupant Load Factor:
UFC 3-101-01: Architecture - 16 Dec 2020 Chapter 11 - Accessibility Group B / IIB = 75 Feet High Occupant Load:
UFC 1-200-02: High Performance and Sustainable Building Requirements - 01 Dec 2020 IBC Table 504.3:
UFC 1-200-01: DoD Building Code; Change 1, 1 Oct 2020 Allowable Building Height
Core Uniform Facility Criteria (UFC) All references to IBC, Chapter 10 must be considered to be references to UFC-3-600-01, which cites cites NFPA 101. Do not use IBC, Chapter 10 for determining means of egress.
The entire building meets the requirements for 2 exits maximum per NFPA 101, Section 38.2.4 and Section 38.2.5 with subsections included.
Chapter 10 - Means of Eagress Sprinklered: Yes 2 Exits
Department of Defense (DoD) Design Requirements: Type IIB
IBC Table 601 NFPA 101, Section 38.2.4 including subsections: The building does not meet the requirements for 1 exit only however areas of the building can be served by a single exit per this section.
Applicable Design Criteria and Codes: Construction Type: 1 Exit Only
Number of Exits:
Charlotte, NC ICC - International Building Code (IBC) as modified by Chapter 2, 3, and 4 of UFC 1-200-01 through reference to core UFC, other UFC as identified in Appendix A, References, and other listed miltiary criteria in UFC 1-200-01. In conflicts between the IBC and military criteria use the military criteria.
IBC Section 311 - Storage Group S, IBC 311.2 Group S1 - Aircraft Hangar 50 or more people per NFPA 101, Section 38.2.3.2 44-inches minimum
Charlotte/Douglas International Airport Building Code: IBC Section 304.1: Business Group B (Professional services)-Office 49 or less people per NFPA 101, Section 7.3.4.1.2 36-inches minimum
Repair Maintenance Hangar, BLDG 51 Required Core Design References Building Occupancy Classifications: Clear width of any corridor or passageway
Project Name and Location: Capacity of Means of Egress:
APPLICABLE CODES AND DESIGN CRITERIA ADMINISTRATION OF CODES AND DESIGN CRITERIA FIRE PROTECTION AND LIFE SAFETY ANALYSIS FIRE PROTECTION AND LIFE SAFETY ANALYSIS, CONTINUED
CODE ANALYSIS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281
/1
/2
:3 :1
P
M C
R e v it L o c a l\
.0
-A -R c h ri s .d o u g a n
.r v t
ROOM OCCUPANCY
CLASSIFICATIONS
FJRP112701ANG PRO. NO.:
3258000-181469.01
KB
DMD
July 20, 2022
ATM
N C
A N
G
T
H A
W
C H
A R
L O
T T
E D
O U
G L A
S I A
P C
H A
R L O
T T
E N
O R
T H
C A
R O
L
IN
A
R E
P A
IR
M
A
IN
T E
N A
N C
E H
A N
G A
R B
U
IL
D
IN
G
G-004A
OCCUPANT LOAD CALCULATIONS
FUNCTION OF ROOM AREA
OCCUPANT LOAD
FACTOR GROSS-NET
ROOM OCCUPANCY
TOTAL
Accessory Storage areas, Mech equipment room 4,311 SF 300 Gross 30
4,311 SF 30
Aircraft Hangars 32,000 SF 500 Gross 64
32,000 SF 64
Assembly without fixed seats - Unconcentrated (tables & chairs) 2,341 SF 15 Net 152
2,341 SF 152
Business Areas 19,145 SF 150 Gross 192
19,145 SF 192
Classrom 678 SF 20 Net 34
678 SF 34
Collaboration<=450SF 428 SF 30 Net 16
428 SF 16
Locker Rooms 566 SF 50 Gross 13
566 SF 13
Storage 2,143 SF 500 Net 5
2,143 SF 5
110 61,612 SF 506
F .E
F.E
F.E
F.E
F.E
F.E.
F.E.
R
EF.
R E
F
R
EF.
DN
DN
UP
UP
S T
A
IR
STAIR
S T
A
IR
S T
A
IR
F .E
Room Occupant Load Factors
Accessory Storage areas, Mech equipment room
Aircraft Hangars
Aircraft Hangers
Assembly without fixed seats - Unconcentrated (tables & chairs)
Business Areas
Classrom
Collaboration<=450SF
Locker Rooms
Storage
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281
/1
/2
:3 :4
P
M C
R e v it L o c a l\
.0
-A -R c h ri s .d o u g a n
.r v t
OCCUPANCY PLANS
FJRP112701ANG PRO. NO.:
3258000-181469.01
KB
DMD
July 20, 2022
ATM
N C
A N
G
T
H A
W
C H
A R
L O
T T
E D
O U
G L A
S I A
P C
H A
R L O
T T
E N
O R
T H
C A
R O
L
IN
A
R E
P A
IR
M
A
IN
T E
N A
N C
E H
A N
G A
R B
U
IL
D
IN
G
G-004B
1/16" = 1'-0"1
FIRST FLOOR OCCUPANCY PLAN
1/16" = 1'-0"2
SOUTH MEZZANINE OCCUPANCY PLAN
F.E
F.E
F.E
F.E
F.E.
F.E.
R
EF.
R E
F
R
EF.
DN
DN
11' 10"
' 2
' M
A X
' M A
X
REF.
FOR LIFE SAFEY
PLAN OF THIS AREA
1/ G-005B
REF.
FOR LIFE SAFEY
PLAN OF THIS AREA
2/ G-005B
REF.
FOR LIFE SAFEY
PLAN OF THIS AREA
3/ G-005A2
REF.
FOR LIFE SAFEY
PLAN OF THIS AREA
2/ G-005A2
6'
0"
7'
3"
116' - 2"
M A
X
7'
-3
'-6
'-9
0'
-0 " M
AX 8'-0" + 116'-2" + 11'-4" = 135'-6"
150'-0" M
AX
34"
2"
46"
2"
72"
2"
72"
2"
34"
2"
34"
2"
M
A X
H1-1
H2-1
H6-1
H7-1
H4-1 H5-1
5.000°
F.E
F.E.
F.E .C
CEILING MOUNT / PENDANT MOOUNT EXIT SIGN,
SHADED QUADRANT (S) DENOTES ILLUMINATED
FACE OF SIGN. ARROW DESIGNATES CHEVRON
INDICATING DIRECTION OF TRAVEL.
(SEE ELECTRICAL DRAWINGS FOR EXIT LIGHT
LOCATIONS)
FIRE / LIFE SAFETY /
MEANS OF EGRESS LEGEND
WALL MOUNTED EXIT SIGN WITH SAME
DESIGNATIONS NOTED ABOVE.
(SEE ELECTRICAL DRAWINGS FOR EXIT LIGHT
LOCATIONS)
DIRECTION OF TRAVEL
POINT OF BEGINNING (POB) IN PATH
OF EXIT ACCESS TRAVEL DISTANCE
X
EXISTING WALL HUNG F.E
F.E
EXISTING FEC
1 HR RATED FIRE BARRIER
1 HR RATED WALLS,FLOOR PENETRATIONS,
CEILING AND STRUCTURE ABOVE.
CLASS 1 DIV 2 HAZARD AREA
OCCUPANTS
INCHES REQUIRED
INCHES PROVIDED
EGRESS DOOR TAG
XX
XX"
XX"
KEY PLAN
A
B
C
SHOP
SOUTH
SHOP
NORTH
B2
A2
A2
C2
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281
/1
/2
:4 :0
P
M C
R e v it L o c a l\
.0
-A -R c h ri s .d o u g a n
.r v t
LIFE SAFETY PLAN -
AREA A
FJRP112701ANG PRO. NO.:
3258000-181469.01
KB
DMD
July 20, 2022
ATM
N C
A N
G
T
H A
W
C H
A R
L O
T T
E D
O U
G L A
S I A
P C
H A
R L O
T T
E N
O R
T H
C A
R O
L
IN
A
R E
P A
IR
M
A
IN
T E
N A
N C
E H
A N
G A
R B
U
IL
D
IN
G
G-005A
1/16" = 1'-0"1
FIRST FLOOR LIFE SAFETY PLAN - AREA A
PATH OF TRAVEL - HANGAR
EXIT ROUTE DISTANCE
H1-1 90' - 0"
H1-2 38' - 5"
H2-1 128' - 5"
H2-2 160' - 6"
H4-1 63' - 11"
H4-2 11' - 9"
H5-1 63' - 11"
H5-2 9' - 4"
H6-1 114' - 1"
H6-2 8' - 4"
H7-1 93' - 3"
H7-2 64' - 9"
HCH 258' - 10"
HCL 257' - 0"
HE-1 28' - 0"
HM-1 106' - 2"
HN3 101' - 9"
HN-1 41' - 1"
HN-2 46' - 7"
HS-1 63' - 7"
HS-2 70' - 2" 07/20/22 B-3 SUBMITTAL
F.E
R E
F
F.E.
R
EF.
DN
UP
UP
S T
A
IR
STAIR
S T
A
IR
S T
A
IR
F .E
CEILING MOUNT / PENDANT MOOUNT EXIT SIGN,
SHADED QUADRANT (S) DENOTES ILLUMINATED
FACE OF SIGN. ARROW DESIGNATES CHEVRON
INDICATING DIRECTION OF TRAVEL.
(SEE ELECTRICAL DRAWINGS FOR EXIT LIGHT
LOCATIONS)
FIRE / LIFE SAFETY /
MEANS OF EGRESS LEGEND
WALL MOUNTED EXIT SIGN WITH SAME
DESIGNATIONS NOTED ABOVE.
(SEE ELECTRICAL DRAWINGS FOR EXIT LIGHT
LOCATIONS)
DIRECTION OF TRAVEL
POINT OF BEGINNING (POB) IN PATH
OF EXIT ACCESS TRAVEL DISTANCE
X
EXISTING WALL HUNG F.E
F.E
EXISTING FEC
1 HR RATED FIRE BARRIER
1 HR RATED WALLS,FLOOR PENETRATIONS,
CEILING AND STRUCTURE ABOVE.
CLASS 1 DIV 2 HAZARD AREA
OCCUPANTS
INCHES REQUIRED
INCHES PROVIDED
EGRESS DOOR TAG
XX
XX"
XX"
REF.
FOR LIFE SAFEY
PLAN OF THIS AREA
1/ G-005B
34"
6"
68"
1"
34"
1"
34"
6"
68"
0"
H134
H141
H144A
H144
H145
H142A
H142
H146
H143H140
H130 H131
H146A
H135
H132
H135A
H133
HN3
HE-1
HN-2
HN-1
F .E
.C
68"
0"
34"
2"
68"
0"
68"
2"
34"
0"
34"
4"
34"
2"
H115 H116H113
H117H114
H110
H112C
H112A
H112B
H112
H111
H6-2
HS-1
HS-2
H7-2
HM-1
H118
F.E.C.
F .E
.C
H247
HM-1
KEY PLAN
A
B
C
SHOP
SOUTH
SHOP
NORTH
B2
A2
A2
C2
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281
/1
/2
:3 :5
P
M C
R e v it L o c a l\
.0
-A -R c h ri s .d o u g a n
.r v t
LIFE SAFETY PLANS -
AREA A2
FJRP112701ANG PRO. NO.:
3258000-181469.01
KB
DMD
July 20, 2022
ATM
N C
A N
G
T
H A
W
C H
A R
L O
T T
E D
O U
G L A
S I A
P C
H A
R L O
T T
E N
O R
T H
C A
R O
L
IN
A
R E
P A
IR
M
A
IN
T E
N A
N C
E H
A N
G A
R B
U
IL
D
IN
G
G-005A2
1/16" = 1'-0"3
FIRST FLOOR LIFE SAFETY PLAN -
HANGAR NORTH SHOP
1/16" = 1'-0"2
FIRST FLOOR LIFE SAFETY PLAN -
HANGAR SOUTH SHOP
1/16" = 1'-0"1
SOUTH MEZZANINE LIFE SAFETY PLAN
PATH OF TRAVEL - HANGAR
EXIT ROUTE DISTANCE
H1-1 90' - 0"
H1-2 38' - 5"
H2-1 128' - 5"
H2-2 160' - 6"
H4-1 63' - 11"
H4-2 11' - 9"
H5-1 63' - 11"
H5-2 9' - 4"
H6-1 114' - 1"
H6-2 8' - 4"
H7-1 93' - 3"
H7-2 64' - 9"
HCH 258' - 10"
HCL 257' - 0"
HE-1 28' - 0"
HM-1 106' - 2"
HN3 101' - 9"
HN-1 41' - 1"
HN-2 46' - 7"
HS-1 63' - 7"
HS-2 70' - 2"
DN
REF.
CEILING MOUNT / PENDANT MOOUNT EXIT SIGN,
SHADED QUADRANT (S) DENOTES ILLUMINATED
FACE OF SIGN. ARROW DESIGNATES CHEVRON
INDICATING DIRECTION OF TRAVEL.
(SEE ELECTRICAL DRAWINGS FOR EXIT LIGHT
LOCATIONS)
FIRE / LIFE SAFETY /
MEANS OF EGRESS LEGEND
WALL MOUNTED EXIT SIGN WITH SAME
DESIGNATIONS NOTED ABOVE.
(SEE ELECTRICAL DRAWINGS FOR EXIT LIGHT
LOCATIONS)
DIRECTION OF TRAVEL
POINT OF BEGINNING (POB) IN PATH
OF EXIT ACCESS TRAVEL DISTANCE
X
EXISTING WALL HUNG F.E
F.E
EXISTING FEC
1 HR RATED FIRE BARRIER
1 HR RATED WALLS,FLOOR PENETRATIONS,
CEILING AND STRUCTURE ABOVE.
CLASS 1 DIV 2 HAZARD AREA
OCCUPANTS
INCHES REQUIRED
INCHES PROVIDED
EGRESS DOOR TAG
XX
XX"
XX"
N113A
N141
N143
N145
N144
N142
N111
N131
N130
N132
N110
N108 N131A
N116
N153C
N153A
N153B
N153 N153E
N153F
N117
N115 N153D
70"
29"
70"
3"
34"
1"
40"
1"
N152 N161
N123
N101
N102 N103
N110A
N104B
N104
N160
N150
N151
N113
N113B
N125A
N121
N121A
N118
N121C
N100
N121B
N104A
N112
N110B
N110AA
N146
N124
N107
N109
N122
N125
N140
46"
2"
12 36"
2"
34"
1"
N-3 H2-2
N-2
N-1
N-7
N-8
N-6
N-5
H4-2
N-9N-4 F.E.C.
F .E
.C
F.E.C.
F.E.C.
F.E.
F .E
F.E.C.
E106
E104
E105 E102
E108 E101
E110
E115
E116
E121
E100
E108A
E118
E117
E120
E122
E125
E103
E119
E123C
E123A
E123
E123B
E107
E107A
E123D
70"
6"
72"
2"
70"
16"
36"
0"
E126
E-5 E-5
E-3
H5-2
E-1
E-2
F.E.
F .E
.C
F .E
.C
KEY PLAN
A
B
C
SHOP
SOUTH
SHOP
NORTH
B2
A2
A2
C2
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281
/1
/2
:4 :1
P
M C
R e v it L o c a l\
.0
-A -R c h ri s .d o u g a n
.r v t
LIFE SAFETY PLANS -
AREA B & C
FJRP112701ANG PRO. NO.:
3258000-181469.01
KB
DMD
July 20, 2022
ATM
N C
A N
G
T
H A
W
C H
A R
L O
T T
E D
O U
G L A
S I A
P C
H A
R L O
T T
E N
O R
T H
C A
R O
L
IN
A
R E
P A
IR
M
A
IN
T E
N A
N C
E H
A N
G A
R B
U
IL
D
IN
G
G-005B
1/16" = 1'-0"1
FIRST FLOOR LIFE SAFETY PLAN - AREA B
1/16" = 1'-0"2
FIRST FLOOR LIFE SAFETY PLAN - AREA C
PATH OF TRAVEL - AREA B
EXIT ROUTE DISTANCE
N-1 62' - 1"
N-2 89' - 6"
N-3 91' - 8"
N-4 178' - 8"
N-5 149' - 10"
N-6 93' - 7"
N-7 96' - 6"
N-8 116' - 11"
N-9 75' - 11"
PATH OF TRAVEL - AREA C
EXIT ROUTE DISTANCE
E-1 67' - 3"
E-2 101' - 10"
E-3 72' - 9"
E-4 15' - 5"
E-5 127' - 9"
HCL
CEILING MOUNT / PENDANT MOOUNT EXIT SIGN,
SHADED QUADRANT (S) DENOTES ILLUMINATED
FACE OF SIGN. ARROW DESIGNATES CHEVRON
INDICATING DIRECTION OF TRAVEL.
(SEE ELECTRICAL DRAWINGS FOR EXIT LIGHT
LOCATIONS)
FIRE / LIFE SAFETY /
MEANS OF EGRESS LEGEND
WALL MOUNTED EXIT SIGN WITH SAME
DESIGNATIONS NOTED ABOVE.
(SEE ELECTRICAL DRAWINGS FOR EXIT LIGHT
LOCATIONS)
DIRECTION OF TRAVEL
POINT OF BEGINNING (POB) IN PATH
OF EXIT ACCESS TRAVEL DISTANCE
X
EXISTING WALL HUNG F.E
F.E
EXISTING FEC
1 HR RATED FIRE BARRIER
1 HR RATED WALLS,FLOOR PENETRATIONS,
CEILING AND STRUCTURE ABOVE.
CLASS 1 DIV 2 HAZARD AREA
OCCUPANTS
INCHES REQUIRED
INCHES PROVIDED
EGRESS DOOR TAG
XX
XX"
XX"
KEY PLAN
A
B
C
SHOP
SOUTH
SHOP
NORTH
B2
A2
A2
C2
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281
/1
/2
:4 :1
P
M C
R e v it L o c a l\
.0
-A -R c h ri s .d o u g a n
.r v t
LIFE SAFETY PLAN -
LOW CATWALK
FJRP112701ANG PRO. NO.:
3258000-181469.01
KB
DMD
July 20, 2022
ATM
N C
A N
G
T
H A
W
C H
A R
L O
T T
E D
O U
G L A
S I A
P C
H A
R L O
T T
E N
O R
T H
C A
R O
L
IN
A
R E
P A
IR
M
A
IN
T E
N A
N C
E H
A N
G A
R B
U
IL
D
IN
G
G-006A
1/16" = 1'-0"1
LOWER CATWALK LIFE SAFETY PLAN
HCH
CEILING MOUNT / PENDANT MOOUNT EXIT SIGN,
SHADED QUADRANT (S) DENOTES ILLUMINATED
FACE OF SIGN. ARROW DESIGNATES CHEVRON
INDICATING DIRECTION OF TRAVEL.
(SEE ELECTRICAL DRAWINGS FOR EXIT LIGHT
LOCATIONS)
FIRE / LIFE SAFETY /
MEANS OF EGRESS LEGEND
WALL MOUNTED EXIT SIGN WITH SAME
DESIGNATIONS NOTED ABOVE.
(SEE ELECTRICAL DRAWINGS FOR EXIT LIGHT
LOCATIONS)
DIRECTION OF TRAVEL
POINT OF BEGINNING (POB) IN PATH
OF EXIT ACCESS TRAVEL DISTANCE
X
EXISTING WALL HUNG F.E
F.E
EXISTING FEC
1 HR RATED FIRE BARRIER
1 HR RATED WALLS,FLOOR PENETRATIONS,
CEILING AND STRUCTURE ABOVE.
CLASS 1 DIV 2 HAZARD AREA
OCCUPANTS
INCHES REQUIRED
INCHES PROVIDED
EGRESS DOOR TAG
XX
XX"
XX"
KEY PLAN
A
B
C
SHOP
SOUTH
SHOP
NORTH
B2
A2
A2
C2
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281
/1
/2
:4 :2
P
M C
R e v it L o c a l\
.0
-A -R c h ri s .d o u g a n
.r v t
LIFE SAFETY PLAN -
UPPER CATWALK
FJRP112701ANG PRO. NO.:
3258000-181469.01
KB
DMD
July 20, 2022
ATM
N C
A N
G
T
H A
W
C H
A R
L O
T T
E D
O U
G L A
S I A
P C
H A
R L O
T T
E N
O R
T H
C A
R O
L
IN
A
R E
P A
IR
M
A
IN
T E
N A
N C
E H
A N
G A
R B
U
IL
D
IN
G
G-007A
1/16" = 1'-0"1
UPPER CATWALK LIFE SAFETY PLAN
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
710 Avis Drive, #100 Ann Arbor, MI 48108-9649 phone: 810-956-9300 fax: 810-956-9281
NOT FOR CONSTRUCTION
FJRP112701ANG PRO. NO.:
3258000-181469.01
JCE
MJR
JULY 20, 2022
DES
N C
AN
G
5T H
A W
C H
AR
LO
TT
E
D O
U G
LA
S
IA
P
C H
AR
LO
TT
E, N O
R
TH
C
AR
O
LI
N A
R
EP
AI
R
M
AI
N
TE
N
AN
C E
H
AN
G
AR
BU
IL
D
IN
G
07/20/22 B-3 SUBMITTAL
C100
CIVIL LEGEND AND
ABBREVIATIONS
AOA BARRICADE
CONTROL POINT/ BENCHMARK
BARRIER, JERSEY
BOLLARD
BORING
CLEANOUT, SANITARY OR STORM
ELECTRIC METER
ELECTRIC PEDESTAL BOX
ELECTRIC TRANSFORMER BOX
ELECTRIC SERVICE PANEL
ELECTRICAL HANDHOLE/ MANHOLE
ELECTRIC HANDHOLE (PULLBOX)
FIBER OPTIC MANHOLE
FIRE HYDRANT
FLAGPOLE
FUEL SHUT OFF VALVE
FUEL VENT PIPE
GAS MANHOLE
GAS METER
GAS VALVE
GAS VENT PIPE
GATE
GUY ANCHOR
HANDHOLE
IRON PIN
LIGHT BOLLARD
FLOODLIGHT POLE
LIGHT POLE (SINGLE)
LIGHT POLE (DOUBLE)
MARKER, CABLE
MARKER, DUCT
MONITORING WELL
PIEZOMETER
POWER POLE
POWER POLE, DOUBLE
POWER POLE WITH LIGHT
SANITARY SEPTIC TANK VALVE
SANITARY SEWER MANHOLE
SANITARY SEWER VALVE
SANITARY SEWER WET WELL
SIGN (SINGLE POST)
SOIL BORING
STORM INLET, CURB
STORM INLET, ROUND
STORM INLET, SQUARE
STORM FLARED END SECTION
STORM SEWER MANHOLE
STORM WATER QUALITY MANHOLE
TELECOMMUNICATIONS MANHOLE
TELECOMMUNICATIONS PEDESTAL BOX
CTV PEDESTAL BOX
TRAFFIC FLOW DIRECTION
TREE / SHRUB
UTILITY CROSSING / CONFLICT or CAUTION
UNDERDRAIN FLUSHER RISER
UNDERDRAIN MANHOLE
VALVE MANHOLE
WATER AIR RELIEF VALVE
WATER BLOW OFF VALVE
WATER MANHOLE
WATER METER
WATER PRESSURE VALVE
WATER REDUCER
WATER VALVE
WATER SHUT OFF
WATER TANK
WETLAND DATAPOINT
WATER SURFACE
SECTION REFERENCE
ELEVATION REFERENCE
(SEE X-XXX) SHEET REFERENCE
(SEE X/X-XXX) DETAIL REFERENCE
EXISTING SPOT ELEVATION
FINISHED / PROPOSED SPOT ELEVATION
DRAINAGE FLOW DIRECTION
STRUCTURE PROTECTION
FINISHED / PROPOSED SLOPE
REMOVE
SEDIMENT LOG CHECK DAM
B
CO
M
TRANS
E
E
FO
FSO
FVP
G
GM
G V
GVP
H
IP
C
D
MW
PZ
STV
S
SV
WW
CB
CB
D
WQ
T
T
CTV
FR
UD
MHV
WAV
WBV
W
WM
WV
W V
OSW
WT
DP#
X
X-XXX
X
X-XXX
734.97'
738.76
2%
3:1
AGGREGATE BASE COURSE
AGGREGATE SUBBASE
ASPHALT
ASPHALT OVERLAY
CONCRETE
CONCRETE REMOVAL
EROSION MAT
GROUND, EXISTING
GROUND, PROPOSED
REMOVAL PATTERN
RESTORATION AREA
DRAINAGE LAYER
RIPRAP OUTFALL
STABILIZED CONSTRUCTION ENTRANCE /
CONTRACTOR LAYDOWN AREA
LANDSCAPING ROCK
TOPSOIL
WELDED WIRE REINFORCEMENT
CIVIL SYMBOLS
AIRPORT OPERATION AREA
BUILDING RESTRICTION LINE
ABANDON
ABANDON CONDUIT
ABANDON ELECTRIC, UNDERGROUND
ABANDON GAS, UNDERGROUND
ABANDON SANITARY SEWER
ABANDON STORM SEWER
ABANDON WATER
REMOVE
REMOVE CONDUIT
REMOVE ELECTRIC, UNDERGROUND
REMOVE ELECTRIC, OVERHEAD
REMOVE FENCE
REMOVE FIBER OPTIC CABLE
REMOVE GAS LINE
REMOVE SANITARY SEWER
REMOVE STORM SEWER
REMOVE TELEPHONE
REMOVE WATER LINE
SAW CUT PAVEMENT
AOA
BRL
\\A//
CON\\A//
E\\A//
G\\A//
SS\\A//
SD\\A//
W\\A//
//CON//
//E//
//OHE//
//FNC//
//FOC//
//G//
//SS//
//SD//
//T//
//W//
CIVIL SYMBOLS
PATTERNS
LINES
CONDUIT, GENERIC
COMMUNICATION LINE
PROPOSED ELECTRIC, UNDERGROUND
EXSTING ELECTRIC, UNDERGROUND
EXISTING MAJOR CONTOUR LINES
EXISTING MINOR CONTOUR LINES
PROPOSED MAJOR CONTOUR LINES
PROPOSED MINOR CONTOUR LINES
EXISTING FENCE
EXISTING FIBER OPTIC CABLE
FIRE PROTECTION
EXISTING GAS
GRADING LIMITS
HAUL ROUTE
PROPERTY LINE
CENTERLINE OR BASELINE
RIGHT-OF-WAY
EXISTING SANITARY SEWER
SIGNAL CABLE, UNDERGROUND
SILT FENCE
SEDIMENT LOG
PROPOSED STORM SEWER
EXISTING STORM SEWER / CULVERT
EXISTING TELEPHONE, UNDERGROUND
PROPOSED TELEPHONE, UNDERGROUND
PROPOSED WATER
EXISTING WATER
DITCH
LOW PROFILE BARRICADES
CON
COMM
E xxx(.xx) xxx(.xx) xxx(.xx) xxx(.xx) x
FOC
ROW
SS
S
SSSSSSSSSS
SD
SD
T
W W
XXXXXXXXXXXXXXXXXXXX
E E
G
T
ABBREVIATIONS
L ANGLE
A/C AIR CONDITIONING
AC ALTERNATING CURRENT
ACI AMERICAN CONCRETE INSTITUTE
ADDM ADDENDUM
ADJ ADJACENT, ADJOINING, ADJUSTABLE
AGG AGGREGATE
AI AREA INLET
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
ALUM ALUMINUM
AMP AMPERE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APPD APPROVED
APPROX APPROXIMATE
ARCH ARCHITECT
ASPH ASPHALT
AUTO AUTOMATIC
AVG AVERAGE
AWG AMERICAN WIRE GAUGE
BDRY BOUNDARY
BEV BEVEL
BITUM BITUMINOUS
BL BUILDING LINE
BLDG BUILDING
BLW BELOW
BM BENCHMARK
BO BOTTOM OF
BOT BOTTOM
BRK BRICK
BS BOTH SIDES
BTWN BETWEEN
BW BOTH WAYS
CB CATCH BASIN
CEM CEMENT
CFM CUBIC FEET PER MINUTE
CHK CHECK
CI CAST IRON
CI CURB INLET
CIP CAST-IN-PLACE
CIRC CIRCULAR
CJ CONTROL JOINT
CJ CONSTRUCTION JOINT
CKT CIRCUIT
CL CENTER LINE
cm CENTIMETER(S)
CMU CONCRETE MASONRY UNIT
CND CONDUIT
CO CLEANOUT
CO CONTRACTING OFFICER
CO2 CARBON DIOXIDE
COL COLUMN
CONC CONCRETE
CONN CONNECT
CONSTR CONSTRUCTION
CONT CONTINUE
CONTR CONTRACTOR
COR CONTRACTING OFFICER REPRESENTATIVE
COV COVER
C-C CENTER TO CENTER
CTR CENTER
CU FT CUBIC FEET
CU YD CUBIC YARDS
CYL CYLINDER
DAT DATUM
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIV DIVISION
DL DEAD LOAD
DN DOWN
DR DOOR
DWG DRAWING
DWLS DOWELS
E EAST
EA EACH
EJ EXPANSION JOINT
ELEC ELECTRIC
EMER EMERGENCY
EST ESTIMATE(D)
EXC EXCAVATE
EX EXISTING
EXP EXPANSION
EXT EXTERIOR
F FAHRENHEIT
FC FOOT CANDLE
FH FIRE HYDRANT
FIG FIGURE
FFE FINISH FLOOR ELEVATION
FN FENCE
FPM FEET PER MINUTE
FT FEET
FTG FOOTING
FUT FUTURE
FW FIRE WATER
G NATURAL GAS
GA GAGE
GAL GALLON(S)
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERAL
GI GALVANIZED IRON
G GROUND
GOVT GOVERNMENT
GPM GALLONS PER MINUTE
GR LN GRADE LINE
HB HOSE BIBB
HH HANDHOLE
HORIZ HORIZONTAL
HP HORSEPOWER
HPT HIGH POINT
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATING AND AIR CONDITIONING
Hz HERTZ
ID INSIDE DIAMETER
IN INCH
INCL INCLUDED
INT INTERIOR
INV INVERT
IP IRON PIPE
J-BOX JUNCTION BOX
JCT JUNCTION
JST JOIST
JT JOINT
KIP KILOPOUND (1000 POUNDS)
kV KILOVOLTS kVA KILOVOLT AMPERES kW KILOWATT
KWY KEYWAY
LAB LABORATORY
LB POUND
LD LOAD
LG LENGTH
LL LIVE LOAD
LM LUMEN
LONG LONGITUDINAL
LPT LOW POINT
LT LIGHT
LT WT LIGHTWEIGHT
m METER(S)
MAS MASONRY
MATL MATERIAL(S)
MAX MAXIMUM
MECH MECHANICAL
MED MEDIUM
MFG MANUFACTURING
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
mm MILLIMETER(S)
MOD MODIFIED
N NORTH
NAT NATURAL
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
OPP OPPOSITE
OPS OPERATIONS
PC PIECE
PCC PORTLAND CEMENT CONCRETE
PCF POUNDS PER CUBIC FOOT
PD PAVEMENT DRAIN
PED PEDESTAL
PERF PERFORATE(D)
PERIM PERIMETER
PH PHASE
PHAR PHARMACY
PI POINT OF INTERSECTION
PL PROPERTY LINE
PLF POUNDS PER LINEAR FOOT
PT POINT
PPM PARTS PER MILLION
PR PAIR
PREFAB PREFABRICATE(D)
PRKG PARKING
PROJ PROJECT
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT
PVC POLYVINYL CHLORIDE
QT QUART
QTR QUARTER
QTY QUANTITY
R RADIUS
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
REF REFERENCE
REIN REINFORCE
REM REMOVE(ABLE)
REQD REQUIRED
RET RETURN
REV REVISION
RM ROOM
RND ROUND
ROW RIGHT OF WAY
S SOUTH
SB SPLASH BLOCK
SCHED SCHEDULE
SCT STRUCTURAL CLAY TILE
SD STORM DRAIN
SECT SECTION
SHLDR SHOULDER
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
STA STATION
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SYM SYMMETRICAL
SYS SYSTEM
TAN TANGENT
TEL TELEPHONE
TEMP TEMPERATURE
TEMP TEMPORARY
THK THICK(NESS)
THRES THRESHOLD
TO TOP OF
TOL TOLERANCE
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSVERSE
TV TELEVISION
TYP TYPICAL
UGND UNDERGROUND
UNEX UNEXCAVATED
UTIL UTILITY
V VOLT
VCT VITRIFIED CLAY TILE
VERT VERTICAL
VOL VOLUME
W WEST
W/ WITH
WI WROUGHT IRON
WM WIRE MESH
W/O WITHOUT
WP WEATHERPROOF
WS WATERSTOP
WT WEIGHT
WTH WIDTH
W-W WALL TO WALL
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
WWR WELDED WIRE REINFORCEMENT
XFMR TRANSFORMER
YD YARD
F F
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X
X
X
X
X
X
X
X X
X
B
B
X
X
X
X X
X
BB
B B
X
0.
0'
0.
0'
5.
0'
5.
0'
720.0'
0.
0'
0.
0'
725.0'
5.
0'
5.
0'
W W W W W W W W W W W W W W W
W
W
W
W
W
E
E
E E
E
E E E E
E E
E E
E
E
E
E
E
E
SS SS SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
E E
E E
E E E E E
E E
E
E
E
E
E
E E
E
EEE
E
E
E
EE
E
E
E
E
E
W V
MW
MW
G
G G G G
F
F F
F F
F
F
F
F
F
F
F
F F F F F F F F F F F F F F
F
SS
SD
SS
SD
F F F F F F F
W
W
W
W
W
F
F
F
W
W
W
W
W W
W W
W
W
W
W
W
W
W W
W W
W W
W W
W W
W W
F F
F F
F
W V W V
W V
W V
W V
CB
CB
CB
CB
CB
CB
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .