ATTACHMENT 7 - Appendix I1 Bangor Fuel Cell Hangar-Exterior Materials Package-RTA.pdf
PDF 1 MB Posted
- Solicitation number
- W50S8326BA001
- Issued by
-
Department of the Army National Guard
About this file
This is a Type B-3 Submittal document for exterior finishes for the ME ANG Fuel Cell Hangar project (Project Number FKNN159044) located in Bangor, Maine. The project is being prepared for the Maine Air National Guard (ME ANG) by BlairRemy Architects and Otie Merrick Joint Venture.
The exterior finishes package specifies materials and color selections for the new Fuel Cell Hangar facility, which will serve the 101st Air Refueling Wing and include a hangar bay, restrooms, tool room, supervisor's office, multipurpose room, and support spaces. The design employs Federal Standard colors to maintain open competition among qualified manufacturers: Federal Standard #26492 (LRV 47, SRI 63) for canopies, standing seam metal roof, fascia, gutters, downspouts, and related drainage components; Federal Standard #27925 (LRV 70, SRI 82) for composite metal panels, insulated metal panels, translucent panel frames, louvers, flashing, soffits, and door trim; and Federal Standard #26134 (LRV 13, SRI 19) for personnel and overhead doors and frames. Additional specifications include brick veneer exterior finishes with horizontal metal panels for the shops section and vertical metal panels for the hangar section, translucent panels for daylighting, premanufactured canopies at all personnel and overhead doors, and signage in accordance with UFC 3-120-01. The document references design standards including ANGETL 15-01, ANGETL 10-03, UFC 3-120-01, UFC 3-101-01, UFC 4-211-01, and UFC 4-211-02. Products listed in construction documents serve as the basis of design, with substitutions permitted if quality and performance characteristics meet or exceed the specified standards. The submittal includes finish material samples, a comprehensive finish materials list covering exterior and interior elements, and detailed color specifications organized by building component.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ME ANG Fuel Cell Hangar
Bangor, Maine
Project Number: FKNN159044
Exterior Finishes Package— Type B-3 Submittal
AUGUST 2025
Prepared for:
Maine Air National Guard
Prepared by:
601 NE 63rd Street
Oklahoma City, OK 73105
5970 Greenwood Plaza Boulevard
Greenwood Village, CO 80111
This page intentionally left blank.
Exterior Finishes
Project No. FKNN159044
TABLE OF CONTENTS
PART 1— EXTERIOR FINISHES NARRATIVE
PART 2—EXTERIOR FINISH SAMPLES
PART 3—DRAWINGS
Finish Materials List
Project No. FKNN159044
PART 1
EXTERIOR FINISHES NARRATIVE
Project No. FKNN159044
EXTERIOR FINISHES NARRATIVE
DESIGN REFERENCES:
ANGETL 15-01 Air National Guard Design Policy
ANGETL 10-03 Air National Guard Design Objectives and Procedures
UFC 3-120-01 Design: Sign Standards, with Change 4
UFC 3-101-01 Architecture, with Change 4
UFC 4-211-01 Aircraft Maintenance Hangars
UFC 4-211-02 Aircraft Corrosion Control and Paint Facilities
INTRODUCTION
This project will provide a Fuel Cell Hangar for the 101st Air Refueling Wing (101 ARW) of the Maine Air National
Guard (ME ANG). The new facility will include a Hangar Bay, clean and dirty restrooms and showers, Tool Room, Super-visor’s Office, Multipurpose Room which will function as both a break room and open office, and building support spaces.
COMPREHENSIVE INTERIOR DESIGN (CID)
The goal of the Comprehensive Interior Design (CID) for the new Fuel Cell Hangar is to create a safe, functional, and attractive space in which to carry out the mission of 101 ARW.
FURNITURE, FIXTURES AND EQUIPMENT (FF&E)
The FF&E package has been provided under a separate cover.
STRUCTURAL INTERIOR DESIGN (SID)
The SID package has been provided under separate cover
EXTERIOR FINISHES
The design of the project includes the selection and coordination of interior and exterior materials and finishes. These finishes have been selected from a cool, analogous color scheme compatible with the character of the surrounding facili-ties. Exterior finishes have been selected to match adjacent building 499. In cases where products used for building 499 are unavailable, a product that closely matches its aesthetic and performance characteristics will be specified.
All products listed in the construction documents are the basis of design. Products from other manufacturers may be substituted provided that the standard of quality and characteristics of the substituted material meet or exceed the stand-ard of quality and characteristics of the basis of design.
Project No. FKNN159044
Federal Standard LRV SRI Applied To
#26492 47 63 Canopies
SSMR
Fascia
Gutters
Downspouts
Cast Iron Boots
Access Hatch
#27925 70 82 Composite Metal Panels
Insulated Metal Panels
Translucent Panel Frames
Light Fixture Housing
Louvers
Flashing
Soffits
Personnel Door Trim
#26134 13 19 Personnel Doors
Personnel Door Frames
Overhead Doors
Overhead Door Frames
#24158 - - Knox Box
#13591 - - Access Hatch Railing
Bollards
#24081 - - Light Fixture Housing
Signage
Signage will be provided for the exterior of the building in accordance with UFC 3-120-01. Dimensional facility num-ber signs will be provided at both the north and south facades. A freestanding, post and panel sign will be provided facing Glenn Avenue.
Exterior Finishes
A standing seam metal roof (SSMR) will be provided along with associated drainage products, and snow guards.
Exterior finishes for the shops will be brick veneer with horizontal metal panels above, while the hangar will receive brick with vertical metal panels above. Translucent panels will be utilized at the hangar to provide daylighting. Pre-manufactured canopies will be provided at all personnel and overhead doors.
Federal Standard colors have been used in the design documents to ensure competition is kept free and open to all qualified manufacturers. Their equivalent color names have been listed below.
Project No. FKNN159044
PART 2
EXTERIOR FINISH SAMPLES
Project No. FKNN159044
PART 3
DRAWINGS
EXTERIOR FINISHES INTERIOR FINISHES GENERAL SHEET NOTES
CODE MFR/DESCRIPTION
FLOORS:
E-EPOXY:
E-1 5-COAT FUEL RESISTIVE EPOXY FLOORING, FINISH: SLIP-RESISTANT,
COLOR: MEDIUM GRAY
E-2 FLECKED EPOXY FLOORING, COLOR: GRAY WITH GREEN AND WHITE CHIPS
LIN-LINOLEUM:
LIN-1 SHEET LINOLEUM FLOORING, COLOR: MEDIUM GRAY
SDV -STATIC DISSIPATIVE VINYL TILE:
SDV-1 STATIC DISSIPATIVE VINYL FLOOR TILE FLOORING, COLOR: BEIGE WITH BLUE VEINING, SIZE: 24" x 24"
SC-SEALED CONCRETE
SC-1 SEALED CONCRETE
EM-ENTRANCE MAT:
EM-1 RECESSED ALUMINUM GRID ENTRY MAT WITH CARPET INSERTS, COLOR: CHARCOAL
WALLS:
P-PAINT:
P-1 WALL PAINT / COOL WHITE
P-2 SHERWIN WILLIAMS / SW6176 LIVEABLE GREEN
P-3 SHERWIN WILLIAMS / SW7044 AMAZING GRAY
P-4 WALL PAINT / COOL LIGHT GRAY
T-TILE:
T-1 SLATE-LOOK WALL TILE, COLOR: DARK GREEN, SIZE: 12" x 12", INSTALLATION: STACK BOND, GRT-1
T-2 SLATE-LOOK MOSAIC WALL TILE, COLOR: BEIGE/RED/GREEN/BLACK, SIZE: 4" x 12", GRT-1
T-3 SLATE-LOOK WALL TILE, COLOR: DARK GREEN, SIZE: 3" x 3", INSTALLATION: STACK BOND, GRT-1
TE-TILE EDGING:
TE-1 COVE PROFILE, FINISH: SATIN NICKEL ANODIZED ALUMINUM
TE-2 RADIUS PROFILE, FINISH: SATIN NICKEL ANODIZED ALUMINUM
GRT-GROUT:
GRT-1 EPOXY GROUT, COLOR: BEIGE
RB-RESILIENT WALL BASE:
RB-1 RUBBER WALL BASE WITH TOE, COLOR: CHARCOAL, HEIGHT: 6"
FRP-FIBERGLASS REINFORCED PLASTIC:
FRP-1 FIBERGLASS REINFORCED PLASTIC WALL PANEL, COLOR: LIGHT GRAY,
TEXTURE: PEBBLE EMBOSSED
COUNTERTOPS & WINDOW SILLS:
SSM-SOLID SURFACE MATERIAL:
SSM-1 SOLID SURFACE, COLOR: BEIGE, PATTERN: VEINED WITH MEDIUM PARTICULATES
MILLWORK:
PLAM-PLASTIC LAMINATE:
PLAM-1 WOODGRAIN PLASTIC LAMINATE, COLOR: COOL BROWN, FINISH: FINE GRAIN
SHOWER STALL SURROUND:
SSM-SOLID SURFACE MATERIAL:
SSM-2 SOLID SURFACE, COLOR: WHITE, PATTERN: SMALL PARTICULATES
CEILINGS:
ACT-ACOUSTICAL CEILING TILE:
ACT-1 ARMSTRONG / ULTIMA HIGH NRC SQUARE LAY-IN, SIZE: 24" X 24"
P-PAINT:
P-5 CEILING PAINT / COOL WHITE
1 COLORS LISTED ARE FOR COLOR IDENTIFICATION PURPOSES ONLY. THIS
LISTING IS NOT INTENDED TO LIMIT SELECTION OF SAME QUALITY AND
SIMILAR COLORS, TEXTURES, AND PATTERNS FROM OTHER
MANUFACTURERS
2 PROVIDE COLOR AND FINISH SAMPLES OF ALL EXTERIOR FINISH
MATERIALS TO MAINE AIR NATIONAL GUARD 101 CES FOR FINAL
APPROVAL PRIOR TO ORDERING OR INSTALLING
3 INSTALL TILE AT MINIMUM JOINT WIDTHS RECOMMENDED BY
MANUFACTURER
4 INSTALL CG-1 CORNER GUARDS ABOVE SCHEDULED WALL BASE AT ALL
EXPOSED OUTSIDE GYPSUM WALL BOARD CORNERS
CODE MFR/DESCRIPTION
WINDOWS:
GLAZING COLOR: CLEAR
WINDOWS FRAMES:
P-6 FRAME PAINT, COLOR: DARK WARM GRAY
DOORS:
METAL MATCH P-6
DOOR FRAMES:
METAL MATCH P-6
RAMPS:
RAILINGS:
P-7 RAILING PAINT, COLOR: BRIGHT YELLOW
SPECIALTIES:
SST-STAINLESS-STEEL FLOOR SINK:
SST-1 FLOOR MOUNTED MOP SINK WITH DROP FRONT, COLOR: STAINLESS-STEEL, SIZE: 24" x 24"
CG-CORNER GUARDS:
CG-1 STAINLESS STEEL CORNER GUARDS, SIZE: 2"W x 48"H
TP-TOILET PARTITIONS:
TP-1 HDPE PARTITIONS, FLOOR-MOUNTED OVERHEAD BRACED, COLOR: DARK GREEN
TP-2 HDPE PARTITIONS, FLOOR-MOUNTED OVERHEAD BRACED, COLOR: MEDIUM GRAY
UP-URINAL PARTITIONS:
UP-1 MATCH TP-1
UP-2 MATCH TP-2
LOCKERS:
LD DOUBLE-TIER WARDROBE LOCKER, SIZE: 18"W x 24"D x 72"H, COLOR: LIGHT GRAY
LOCKER BENCHES:
LB LOCKER BENCH WITH SOLID WOOD TOP AND STAINLESS STEEL PEDESTALS, SIZE: 36"W
ROLLER WINDOW SHADES:
RS MANUAL ROLLER SHADE, FABRIC: TIGHT WEAVE, COLOR: CHARCOAL, 3% OPEN
SN-INTERIOR SIGNAGE:
SN-1 INTERIOR SIGN / CHARCOAL
SN-2 INTERIOR SIGN / BEIGE
SN-3 INTERIOR SIGN / SATIN ALUMINUM
CODE MFR/DESCRIPTION
FACADE:
BR-BRICK:
BR-1 CLAY BRICK, COLOR: MEDIUM WARM GRAY, FINISH: VELOUR
CP-COMPOSITE METAL PANELS:
CP-1 MATCH FEDERAL STANDARD #27925
IP-INSULATED METAL PANELS:
IP-1 MATCH FEDERAL STANDARD #27925
TRANSLUCENT PANELS:
PANELS EXTERIOR COLOR: CRYSTAL
INTERIOR COLOR: WHITE
FRAMES MATCH FEDERAL STANDARD #27925
MUNTINS COLOR: BLACK, PATTERN: REVERSE SHOJI
PREMANUFACTURED CANOPIES:
MATCH FEDERAL STANDARD #26492
EXHAUST FANS:
GALVANIZED STEEL
LIGHTING:
HOUSING MATCH FEDERAL STANDARD #24081
LOUVERS:
MATCH FEDERAL STANDARD #27925
ROOF:
SSMR-STANDING SEAM METAL ROOF:
SSMR-1 MATCH FEDERAL STANDARD #26492
FASCIA:
MATCH FEDERAL STANDARD #26492
SOFFITS:
MATCH FEDERAL STANDARD #27925
GUTTERS:
MATCH FEDERAL STANDARD #26492
DOWNSPOUTS:
MATCH FEDERAL STANDARD #26492
CAST IRON BOOTS:
MATCH FEDERAL STANDARD #26492
FLASHING:
MATCH FEDERAL STANDARD #27925
ACCESS HATCH AND RAILING:
HATCH MATCH FEDERAL STANDARD #26492
RAILING MATCH FEDERAL STANDARD #13591
DOORS:
PERSONNEL DOORS:
LEAVES MATCH FEDERAL STANDARD #26134
FRAMES MATCH FEDERAL STANDARD #26134
TRIM MATCH FEDERAL STANDARD #27925
OVERHEAD DOORS:
PANELS MATCH FEDERAL STANDARD #26134
FRAMES MATCH FEDERAL STANDARD #26134
TRIM MATCH FEDERAL STANDARD #27925
HANGAR DOORS:
PANELS MATCH FEDERAL STANDARD #27925
TRIM MATCH FEDERAL STANDARD #27925
SPECIALTIES:
SN-EXTERIOR SIGNAGE:
SN-4 DARK BRONZE
SN-5 REFLECTIVE WHITE
BOLLARDS:
MATCH FEDERAL STANDARD #13591
KNOX BOX:
MATCH FEDERAL STANDARD #24158
FIRE DEPARTMENT CONNECTION:
POLISHED BRASS
FIRE DEPARTMENT HOSE CONNECTION TEST HEADER:
POLISHED BRASS
PROJ:
DESN:
DRWN:
CHKD:
SHEET: OF
Bar measures 1 inch, otherwise drawing is not to scale
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
A
B
C
D
E
F
1 2 3 4 5 6 7
FKNN159044
D.CAVIN
L.PENDERGRAFT
C.SEGHI
M E
A N
G F
U E
L C
E L L H
A N
G A
R
M A
IN
E
A
IR
N A
T
IO
N A
L G
U A
R D
B
A N
G O
R M
E
AF001
F
IN
IS
H
M A
T E
R
IA
L S
L
IS
T
B-3 SUBMITTAL
| Table of Contents |
| Part 1 - Exterior Finishes Narrative |
| Part 2 - Exterior Finish Samples |
| Part 3 - Drawings |
File details come from the government source that posted it. Updated .