Attachment 6 - Drawings Volume V.pdf
PDF 13 MB Posted
- Solicitation number
- 36C77626R0066
About this file
This file is a set of telecommunications demolition drawings for the EHRM Infrastructure Upgrades project at the VA Medical Center in Asheville, NC (Building 47, Project 637-22-700). The drawings (47-TD100 through 47-TD150) provide detailed floor plans and specifications for removing obsolete telecommunications infrastructure across multiple floors of the facility.
The demolition scope includes removal of all existing cabling and infrastructure rated below CAT6A standards, including CAT5E and CAT6 horizontal cables, patch panels not designed for CAT6A, wall plates and RJ-45 jacks, data racks, fiber boxes, fiber cable and enclosures (after new connections are established), and wall-mounted telecommunications equipment. Key items to remain include existing cable tray, copper phone punch down blocks (unless otherwise noted), existing ladder rack, and plywood backboards. The drawings specify that contractors must survey all telecom drop locations prior to construction and report discrepancies to the Design of Record (DOR) immediately. Demolition work must be coordinated with the VA Contracting Officer Representative (COR) to ensure fiber lines are inactive before removal, and all asbestos-exposed items must be disposed of in compliance with VA, EPA, and local standards. The project covers basement, first floor, second floor, and third through fifth floors, with multiple detailed plans for each area showing room locations and equipment to be removed. Existing conduit extending between floors is evaluated for reuse in the new fiber backbone infrastructure or complete demolition based on condition assessment.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Expires12-31-28
BICSI ID # 237176
Jinze Chen
Expires12-31-28
BICSI ID # 237176
Jinze Chen
47-TD401
47-TD400
47-TD400
47-TD400
47-TD400
47-TD400
PLAN
NORTH
N
FOR OFFICIAL USE ONLY
www.coffman.com
701 Corporate Center Drive, Suite 475
Raleigh, NC 27607 ph 919.314.6686
20 20 40
1" = 20'-0"
FEETSCALE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL BID DOCUMENTSFacilities Management
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMP
321 4 5 6 7 8 9 10
SHEET NOTES:
SHEET OF
KEY PLAN
12/18/2025
A u to d e s k D o c s
/A s h e v ill e E
H R
M V
/6
-2 -7
.0
.E
.A S
H
E H
R M
.r v t
/1 /2
:5
:4
P M
47-TD100
TELECOMMUNICATIONS BASEMENT
DEMOLITION - OVERALLAwen Solutions Group
215 N. Payne Street, Suite 122
Alexandria, VA 22314
12.19.2025
EHRM INFRASTRUCTURE
UPGRADES BLDG 47
1100 TUNNEL ROAD
ASHEVILLE, NC 28805
637-22-700
GENERAL NOTES:
1. REFER TO 00-T001 FOR GENERAL NOTES AND LEGENDS.
2. ALL EXISTING CABLES AND INFRASTRUCTURE NOT CAT6A RATED TO BE DEMOLISHED.
3. NOT ALL DEVICES ARE SHOWN. CONTRACTOR TO VERIFY ALL DATA OUTLET LOCATIONS IN THE FIELD.
4. THE QUANTITY OF TELECOM DROPS TO BE REMOVED, INSTALLED, AND MAINTAINED IS BASED ON THE INFORMATION KNOWN AT THE TIME OF DESIGN. PRIOR TO CONSTRUCTION, TELECOM DROP LOCATIONS SHALL BE SURVEYED. ANY DISCREPANCIES SHALL
BE PROVIDED TO THE DOR IMMEDIATELY.
5. EXISTING ROUTING FOR TELECOM DROPS TO REMAIN SHALL BE MAINTAINED TO THE FULLEST EXTENT.
6. DEMOLITION DETAILS (IN NO PARTICULAR ORDER):
A. REFER TO ENLARGED PLANS FOR ADDITIONAL REQUIREMENTS.
B. CABLE CAT6 AND BELOW HORIZONTAL CABLE SHALL BE REMOVED FROM EXISTING PATCH PANELS BACK TO FINAL DATA
JACK LOCATIONS. CABLE SHALL BE REMOVED BETWEEN EXISTING SWITCH AND PATCH PANEL.
C. PATCH PANELS CURRENTLY NOT DESIGNED FOR CAT6A CABLE SHALL BE REMOVED.
D. WALL PLATES AND RJ-45 JACKS FOR WALL OUTLET BOXES FOR CAT5E, 6 AND BELOW CABLE SHALL BE REMOVED.
E. DATA RACKS SHALL BE REMOVED.
F. HORIZONTAL AND VERTICAL CABLE MANAGEMENT FOR RACKS SHALL BE REMOVED IF APPLICABLE.
G. WALL MOUNTED FIBER BOXES SHALL BE REMOVED.
H. FIBER CABLE AND ENCLOSURES SHALL BE REMOVED BACK TO SOURCE AFTER ALL NEW FIBER CONNECTIONS IN THIS
BUILDING HAVE BEEN CONNECTED. PRIOR TO DEMOLITION, COORDINATE WITH VA COR TO ENSURE ALL FIBER IS INACTIVE
BEFORE DEMOLITION.
I. EXISTING CABLE TRAY TO REMAIN.
J. COPPER PHONE PUNCH DOWN BLOCKS SHALL REMAIN UNLESS OTHERWISE NOTED.
7. DEMOLISH ALL TELECOMMUNICATIONS CABLE THAT IS NOT TERMINATED AT BOTH ENDS AT A CONNECTOR OR OTHER EQUIPMENT AND NOT IDENTIFIED 'FOR FUTURE USE' WITH A TAG. ENSURE DEMOLITION OF ABANDONED CABLE WILL NOT DISRUPT VA OPERATIONS PRIOR TO REMOVAL. WHERE DISRUPTION OF SERVICE OCCURS DUE TO DEMOLISHED CABLE, NEW
CABLE SHALL BE INSTALLED TO RESTORE THE SYSTEM AT THE CONTRACTOR'S EXPENSE.
8. PRIOR TO DEMOLITION, COORDINATE DISPOSAL WITH VA. ALL VA STANDARDS, EPA STANDARDS AND LOCAL STANDARDS MUST BE
FOLLOWED WHEN DISPOSING OF ASBESTOS EXPOSED ITEMS.
1" = 20'-0"
1 TELECOMMUNICATIONS BASEMENT DEMOLITION - OVERALL
EXISTING LADDER RACK TO REMAIN (TYP).1
Revisions: Date:
Jinze Chen
/1 47-TD102
/1 47-TD104
/1 47-TD103
D1/1 D1/1
D2/3 V1
D0/3 D2/3
D1/4
D0/1
D1/2
D1/2 D1/1
D2/2 V1
D0/2 V1
D2/2 V2
D1/2 V1
D2/2 V2
D1/2 V1
D2/2 V2
D0/2
D0/1
D3/4 D1/1 D3/3
D1/1
D1/1
D1/1
D2/2 V2
D2/2 V2
D2/2 V2
D0/2 V2
D2/2 V2
DX/X
VX
D2/2 V2
D2/2 V2
D2/2 V2
D2/2 V1
D1/2 V1
D0/1 V1
D1/2 V1
D2/2 V1
D2/2 V1
D1/2 V1
D0/2 V1
D2/3
D2/3
D2/2 V1
D1/2 V1
D1/1
D2/2 V2
D1/1
D2/2
D1/1
D0/2 V2
D1/3
D0/3
D0/1 D0/1
D0/1 D0/1
D0/4 D1/3
D0/2 D0/2
D0/2 D0/1
D2/2 V2
D1/3
STAIR
CORRIDOR
OFFICE
BC141
OFFICE
BC142
TR (DECOMMISSIONED)
BC143
TR TO BE DECOMMISSIONED
PIPE BASEMENT
ELEC
BC140
STOR.
BC139
Room
2B272
TR TO BE DECOMMISSIONED
ENTRANCE ROOM 02 (NEW)
BC143A
ENTRANCE ROOM
CORRIDOR
1C147
STORAGE
BC145
STORAGE CANTEEN
BC148
FITNESS CENTER VAEA
BC147
BARBER
CANTEEN
BC146
BOILER ROOM
BF152
STAIR
A
BLR SPVR
BF155
LOCKER
BF154
CONTROL
BF153
EXISTING AREA WAY
1C402
BIOHAZARD
BF136
TRANSFORMER
BF135
OFFICE POLICE
BF148
TRAINING ROOM
BF149D
TRAINING ROOM B
BF149B
STOR.
POLICE
BF149C
STOR.
POLICE
BF149A
OFFICE POLICE
BF149
HAC FMS
BF147
DETECTIVE
BF146
FEM TLT
BF145
CORRIDOR
BF-B
SEC / WAITIN
BF137
CHIEF POLICE
BF138
ASST CHIEF POLICE
BF141
EMS ASST CHIEF
BF132
M&O FORMAN
BF130
OTHER
BF102
STOR.
BF146A
ARMORY
BF144
MALE LOCKERS
BF143 HOLDING
POLICE
BF139A
MALE TLT
BF142 OPERATIONS POLICE
BF139
STOR POLICE
BF137A
COMM CENTER
BF140
FMS PSA
BF129
VESTIBULE
BF100
CORRIDOR
BF-C
SWITCHGEAR
BF134
MECH RM
BF150
PLUMBING SHOP
BF151
SHOP
BF133
F.E.
1C421
SUPPLY
BF131
CORRIDOR
BF-E
M&O ASST
BF128
EMS SUPERVISORS
BF110
STOR IRM
BC145A
CORRIDOR
BF-D
CORRIDOR
BF100A
Room
1G131F
Room
1G131G
Room
1G131H
Room
1G131I
Room
1G131J
Room
1G131K
5 5 10 15 20 25 30
3/32" = 1'-0"
FEETSCALE
PLAN
NORTH
N
FOR OFFICIAL USE ONLY
www.coffman.com
701 Corporate Center Drive, Suite 475
Raleigh, NC 27607 ph 919.314.6686
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL BID DOCUMENTSFacilities Management
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMP
321 4 5 6 7 8 9 10
SHEET NOTES:
SHEET OF
A
KEY PLAN
12/18/2025
A u to d e s k D o c s
/A s h e v ill e E
H R
M V
/6
-2 -7
.0
.E
.A S
H
E H
R M
.r v t
/1 /2
:5
:4
P M
47-TD101
TELECOMMUNICATIONS BASEMENT
DEMOLITION - PART AAwen Solutions Group
215 N. Payne Street, Suite 122
Alexandria, VA 22314
12.19.2025
EHRM INFRASTRUCTURE
UPGRADES BLDG 47
1100 TUNNEL ROAD
ASHEVILLE, NC 28805
637-22-700
GENERAL NOTES:
1. REFER TO 00-T001 FOR GENERAL NOTES AND LEGENDS.
2. ALL EXISTING CABLES AND INFRASTRUCTURE NOT CAT6A RATED TO BE DEMOLISHED.
3. NOT ALL DEVICES ARE SHOWN. CONTRACTOR TO VERIFY ALL DATA OUTLET LOCATIONS IN THE FIELD.
4. THE QUANTITY OF TELECOM DROPS TO BE REMOVED, INSTALLED, AND MAINTAINED IS BASED ON THE INFORMATION KNOWN AT THE TIME OF DESIGN. PRIOR TO CONSTRUCTION, TELECOM DROP LOCATIONS SHALL BE SURVEYED. ANY DISCREPANCIES SHALL
BE PROVIDED TO THE DOR IMMEDIATELY.
5. EXISTING ROUTING FOR TELECOM DROPS TO REMAIN SHALL BE MAINTAINED TO THE FULLEST EXTENT.
6. DEMOLITION DETAILS (IN NO PARTICULAR ORDER):
A. REFER TO ENLARGED PLANS FOR ADDITIONAL REQUIREMENTS.
B. CABLE CAT6 AND BELOW HORIZONTAL CABLE SHALL BE REMOVED FROM EXISTING PATCH PANELS BACK TO FINAL DATA
JACK LOCATIONS. CABLE SHALL BE REMOVED BETWEEN EXISTING SWITCH AND PATCH PANEL.
C. PATCH PANELS CURRENTLY NOT DESIGNED FOR CAT6A CABLE SHALL BE REMOVED.
D. WALL PLATES AND RJ-45 JACKS FOR WALL OUTLET BOXES FOR CAT5E, 6 AND BELOW CABLE SHALL BE REMOVED.
E. DATA RACKS SHALL BE REMOVED.
F. HORIZONTAL AND VERTICAL CABLE MANAGEMENT FOR RACKS SHALL BE REMOVED IF APPLICABLE.
G. WALL MOUNTED FIBER BOXES SHALL BE REMOVED.
H. FIBER CABLE AND ENCLOSURES SHALL BE REMOVED BACK TO SOURCE AFTER ALL NEW FIBER CONNECTIONS IN THIS
BUILDING HAVE BEEN CONNECTED. PRIOR TO DEMOLITION, COORDINATE WITH VA COR TO ENSURE ALL FIBER IS INACTIVE
BEFORE DEMOLITION.
I. EXISTING CABLE TRAY TO REMAIN.
J. COPPER PHONE PUNCH DOWN BLOCKS SHALL REMAIN UNLESS OTHERWISE NOTED.
7. DEMOLISH ALL TELECOMMUNICATIONS CABLE THAT IS NOT TERMINATED AT BOTH ENDS AT A CONNECTOR OR OTHER EQUIPMENT AND NOT IDENTIFIED 'FOR FUTURE USE' WITH A TAG. ENSURE DEMOLITION OF ABANDONED CABLE WILL NOT DISRUPT VA OPERATIONS PRIOR TO REMOVAL. WHERE DISRUPTION OF SERVICE OCCURS DUE TO DEMOLISHED CABLE, NEW
CABLE SHALL BE INSTALLED TO RESTORE THE SYSTEM AT THE CONTRACTOR'S EXPENSE.
8. PRIOR TO DEMOLITION, COORDINATE DISPOSAL WITH VA. ALL VA STANDARDS, EPA STANDARDS AND LOCAL STANDARDS MUST BE
FOLLOWED WHEN DISPOSING OF ASBESTOS EXPOSED ITEMS.
3/32" = 1'-0"
1 TELECOMMUNICATIONS BASEMENT DEMOLITION - PART A
Jinze Chen
/1 47-TN101
/1 47-TN104
D0/3
D2/4
D2/2 V1
D0/2
D1/2D1/2D2/4D3/3 V1
D2/2 D1/2D0/2
D0/1
D1/2
D0/1
D0/1
D0/1 D2/3
D2/2 V1
D2/2 V1
D2/2 V1
D2/2 V1
D0/2
D1/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D2/3
D2/3
D3/3
D2/2 V1
D2/2 V1
D1/2 V1
D0/2 V2
D1/2 V1
D1/2 V1
D0/2 V1
D0/2 V1
D2/2 V1
D2/2 V1
D1/2 V1
D1/2 V1
D1/2 D1/2 D1/2 D1/2 D1/2
D1/2 D1/2 D1/2 D1/2 D1/2
D1/2 D1/2 D1/2 D1/2 D1/2
D1/2 D1/2 D1/2 D1/2
D1/2
D1/2
D1/2
D1/2
D1/2
D1/2
D0/2
D0/2
D0/2
D0/2
D2/3
D1/1
D1/3
D2/3
D1/1 D1/2 V1
D1/2 V1
D1/2
D0/2 V1
D2/2 V1
D1/2
TR (DECOMMISSIONED)
BA008
TR TO BE DECOMMISSIONED
ELEC
BA007
CORRIDOR
BB061
DATA CENTER (NEW)
BC131B
NEW DATA CENTER
TR (DECOMMISSIONED)
BC143
TR TO BE DECOMMISSIONED
PIPE BASEMENT
Room
1D145
ENTRANCE ROOM 01 (NEW)
BC131A
ENTRANCE ROOM
ELEC
BB068
ELEVATOR MACHINE RM
BA006
ELEV
1C383
ELEV.
1C384
ELEV
1C385
SIGNAL
1C386
TELECOM TO BE DECOMMISSIONED
CORRIDOR
BA001
CORRIDOR
BA003
CORRIDOR
BA
RETAIL STORE
BA010
CORRIDOR
BA037
STORAGE
BA021
OFFICE
BA020 EQUIP'T/ STORAGE
BA021A
CORRIDOR
BA005
LAB & PATH
BA038
WORK AREA
LAB & PATH
BA039
ADA TLT
LAB & PATH
BA042
OFFICE LAB
& PATH
BA057
ADA TLT
LAB & PATH
BA043
CORRIDOR
BA041
CORRIDOR
BA040
CORRIDOR
BA053
STA 2
LAB & PATH
BA056
STA 4
LAB & PATH
BA055
STA 5
LAB & PATH
BA052
STA 3
LAB & PATH
BA054
MICROBIOLOGY LAB & PATH
BB052
ELEVATOR LOBBY
BA004
CORRIDOR
BA002
MALE HC TLT
BB006
MICRO LAB
& PATH
BB057
REFER
BB056
STER / SOLUTION
BB055
BIO-SAFETY
BB054
FLOR-
MICROSCOPE
BB053
STORAGE FMS
BB067
BLOOD BANK
BB058
RECEPTION
LAB & PATH
BB004
LOCKER ROOM
BB003
CORRIDOR
BB
ELECTRICAL
BA017
STAIR
1C401
AREAWAY
BA018
CORRIDOR
BB060
CORRIDOR
BB059
CONFERENCE ROOM
BB001
BREAKROOM
BB002
MECHANICAL
BA012
MECHANICAL
BA009
AREAWAY
1C424
CORRIDOR
BA011
Room
1G131E
5 5 10 15 20 25 30
3/32" = 1'-0"
FEETSCALE
PLAN
NORTH
N
FOR OFFICIAL USE ONLY
www.coffman.com
701 Corporate Center Drive, Suite 475
Raleigh, NC 27607 ph 919.314.6686
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL BID DOCUMENTSFacilities Management
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMP
321 4 5 6 7 8 9 10
SHEET NOTES:
SHEET OF
B
KEY PLAN
12/18/2025
A u to d e s k D o c s
/A s h e v ill e E
H R
M V
/6
-2 -7
.0
.E
.A S
H
E H
R M
.r v t
/1 /2
:5
:5
P M
47-TD102
TELECOMMUNICATIONS BASEMENT
DEMOLITION - PART BAwen Solutions Group
215 N. Payne Street, Suite 122
Alexandria, VA 22314
12.19.2025
EHRM INFRASTRUCTURE
UPGRADES BLDG 47
1100 TUNNEL ROAD
ASHEVILLE, NC 28805
637-22-700
GENERAL NOTES:
1. REFER TO 00-T001 FOR GENERAL NOTES AND LEGENDS.
2. ALL EXISTING CABLES AND INFRASTRUCTURE NOT CAT6A RATED TO BE DEMOLISHED.
3. NOT ALL DEVICES ARE SHOWN. CONTRACTOR TO VERIFY ALL DATA OUTLET LOCATIONS IN THE FIELD.
4. THE QUANTITY OF TELECOM DROPS TO BE REMOVED, INSTALLED, AND MAINTAINED IS BASED ON THE INFORMATION KNOWN AT THE TIME OF DESIGN. PRIOR TO CONSTRUCTION, TELECOM DROP LOCATIONS SHALL BE SURVEYED. ANY DISCREPANCIES SHALL
BE PROVIDED TO THE DOR IMMEDIATELY.
5. EXISTING ROUTING FOR TELECOM DROPS TO REMAIN SHALL BE MAINTAINED TO THE FULLEST EXTENT.
6. DEMOLITION DETAILS (IN NO PARTICULAR ORDER):
A. REFER TO ENLARGED PLANS FOR ADDITIONAL REQUIREMENTS.
B. CABLE CAT6 AND BELOW HORIZONTAL CABLE SHALL BE REMOVED FROM EXISTING PATCH PANELS BACK TO FINAL DATA
JACK LOCATIONS. CABLE SHALL BE REMOVED BETWEEN EXISTING SWITCH AND PATCH PANEL.
C. PATCH PANELS CURRENTLY NOT DESIGNED FOR CAT6A CABLE SHALL BE REMOVED.
D. WALL PLATES AND RJ-45 JACKS FOR WALL OUTLET BOXES FOR CAT5E, 6 AND BELOW CABLE SHALL BE REMOVED.
E. DATA RACKS SHALL BE REMOVED.
F. HORIZONTAL AND VERTICAL CABLE MANAGEMENT FOR RACKS SHALL BE REMOVED IF APPLICABLE.
G. WALL MOUNTED FIBER BOXES SHALL BE REMOVED.
H. FIBER CABLE AND ENCLOSURES SHALL BE REMOVED BACK TO SOURCE AFTER ALL NEW FIBER CONNECTIONS IN THIS
BUILDING HAVE BEEN CONNECTED. PRIOR TO DEMOLITION, COORDINATE WITH VA COR TO ENSURE ALL FIBER IS INACTIVE
BEFORE DEMOLITION.
I. EXISTING CABLE TRAY TO REMAIN.
J. COPPER PHONE PUNCH DOWN BLOCKS SHALL REMAIN UNLESS OTHERWISE NOTED.
7. DEMOLISH ALL TELECOMMUNICATIONS CABLE THAT IS NOT TERMINATED AT BOTH ENDS AT A CONNECTOR OR OTHER EQUIPMENT AND NOT IDENTIFIED 'FOR FUTURE USE' WITH A TAG. ENSURE DEMOLITION OF ABANDONED CABLE WILL NOT DISRUPT VA OPERATIONS PRIOR TO REMOVAL. WHERE DISRUPTION OF SERVICE OCCURS DUE TO DEMOLISHED CABLE, NEW
CABLE SHALL BE INSTALLED TO RESTORE THE SYSTEM AT THE CONTRACTOR'S EXPENSE.
8. PRIOR TO DEMOLITION, COORDINATE DISPOSAL WITH VA. ALL VA STANDARDS, EPA STANDARDS AND LOCAL STANDARDS MUST BE
FOLLOWED WHEN DISPOSING OF ASBESTOS EXPOSED ITEMS.
3/32" = 1'-0"
1 TELECOMMUNICATIONS BASEMENT DEMOLITION - PART B
Jinze Chen
/1 47-TD101
/1 47-TD102
/1 47-TD104
D1/1
D2/2
D1/1
D1/3
D1/1
D0/1
D2/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D2/2 V1
D1/3 V1
D2/2 V2
D2/2 V2
D0/3
D2/3
D1/2 V1
D0/4
D2/3
D1/1
D1/1 D1/1
D1/2D1/2
D1/2 D1/XD1/X
V1
D1/1 V1
D1/2
D2/4
D0/1 V1
D1/3
D1/1 D0/1
D0/3
D3/X
D1/3
D0/1
D1/1 D1/3 V1
D0/4
D1/1
D0/1
D0/4 D1/4
D0/3
D0/4
D1/1 D0/3
D1/2 V2
D0/2 V2
D1/2 V1
D0/4
D4/4
D1/1
D3/4
D1/2
D1/4
D2/4
D2/3
D1/1
D2/3 V1
D0/1
D0/2
D0/2 D1/3
D2/2 V1
D2/2 V1
D1/X
VX
D2/2 V2
D2/3 V1
D1/2 V1
D0/2 V1
D2/2 V1
D0/2 V1
D0/2 V1 D1/4
D0/2 V2
D0/2 V2 D0/2
V2
D2/2
D1/1
D1/1
D0/1
D0/1
D0/1
D0/2 V1
D2/2 V1
D0/2 V1
D2/2 V1
D1/2 V1
D1/6
D0/2
D1/2 V1
D0/3 V1
D1/2 V2
D1/2 V2
D2/3 V1
D2/2 V2
D1/4
D2/2
D1/2
D2/4
D3/4
D2/4
D2/2
D0/1
D1/2 V2
D1/2 V2
D2/2 V1
D1/1
D1/3
D3/3
D2/3
TR (DECOMMISSIONED)
BE119
TR TO BE DECOMMISSIONED
STORAGE
BF106
TR (EXPANDED)
BF107
EXPANDED TR
OFFICE
BF108
LOUNGE
BF109
OFFICE
BE118
HAC
BF111
LOCKER
BF109B
SHOWER
BF109C
MALE TLT
BF109A
CORRIDOR
1C147
VESTIBULE
BF100
A/C SHOP
BF103
STAIR
1C403
ELECT SHOP
BF104
LOCKSMITH
BF105
ELECT SUPER
BF104B
LOUNGE
BF104A
BIOMED SHOP
BF117
BIOMED SUPER
BF117B
MED GAS
WRK RM FMS
BF117A
MALE TLT
FMS
BF119D
HAC
BF119C FEMALE TLT
TLT FMS
BF119B COLD RM LAB
BF119A
MORGUE LAB
BF119
MORGUE
BF119E
MORGUE
BF119F
SOLID WASTE
BF120
WAREHOUSE
BF121
LAUNDRY
BF122
SEAMSTRESS
BF118
ELECTRIC
FMS
BF112
F.E.
BF113
STOR.
BF114
SUPPLIES PHARMACY
BF115
OFFICE
LOGISTICS
BF156
F-LOUNGE
BE125
STORAGE CANTEEN
BE124
F-LOCKER
BE125B
HAC
SPD
BE107
M-LOCKER
BE106
TLT.
BE106A
STAFF LOUNGE
BE104
STORAGE
BE123A
F.E.
BE123B
ELECTICAL
FMS
BE123C
ELECTRICAL
BE123D F-LOCKER
BE105 HAC
BE122
TOILET
BE105A
STERILE SUPPLY
BE103
EQUIP STORAG
BE102A
CART WASH
PASS THRU
1C412
MAIN CART WASH
BE108
CHIEF
BE117
INVENTORY MANAGEMENT
BE116
OFFICE
LOGISTICS
BE115
OFFICE
LOGISTICS
BE115A
BREAK-OUT
BE100
OFFICE
BE100A
OFFICE
BE100B
DISPATCH
BE101
CLEAN SUPPLY
BE102
HAC
BE112
R.O.
BE111
CORR.
SPS
BE110
DECONTAM
BE109
SCOPE ROOM
SPS
BE120 SOILED UTIL
BE121
DIET COMM
BD104
FLAM
STOR BMS
BD102
STERILE PREP
BE113 MULTI-PURPOSE ROOM
BC122
DUPLICATION
BC133
CHIEF
BC138A
OFFICE
CANTEEN
BC138
STORAGE
BC138B
OFFICE
BC137
OFFICE
BE113A
MAIL ROOM
BE114
CLASSROOM #2
BC110
CLASSROOM #1
BC112
ELECTRICAL
FMS
BD120
CLEAN
UTIL N&FS
BD119
OFFICE
BC119B
REFER-VEG
BD105
REFER - THAW
BD111
REFER-EGG
N&FS
BD110
REFER
CONDIMENTS N&FS
BD109
REFER
MOW N&FS
BD108
REFER
COOKS
N&FS
BD106
ELEC
CLOSET FMS
BD113
REFER-MEAT
BD112
HAC
BF123
OXY
STORE
BMS
BF124
OXY
STORE
BMS
BF125
DOCK
DOCK
WAREHOUSE
BF127
CHEM
STOR N&FS
BD124
A/C/SHOP
BF126 PAPER STORE
BD123
OFFICE
BD122
CLASSROOM
N&FS
BD121
SUPERVISORS
BD114
OFFICE
BD114A
FOOD PREP
BD115
POT RM
BD117
REFER-VEG
BD116
CORRIDOR
BF - A
CORRIDOR
BD001
CORRIDOR
AB15N
F.E.
BD103A
F.E.
1C418
INGREDIENT CONTROL
BD107
MAIN KITCHEN
BD103
DISH RM
BD118
ELECTRICAL
BD125
FEMALE TLT
BE125A
STORAGE
BF156A
MALE TLT
BD100
FEMALE TLT
BD101
CORRIDOR
BF100A
STERILIZER
TWO
1C422
STERILIZER
ONE
1C423
WAITING ROOM
IMAGING
BF101
F.E.
TAB15
ELECTRICAL
FMS
BD126
TRASH CHUTE
BD127
5 5 10 15 20 25 30
3/32" = 1'-0"
FEETSCALE
PLAN
NORTH
N
FOR OFFICIAL USE ONLY
www.coffman.com
701 Corporate Center Drive, Suite 475
Raleigh, NC 27607 ph 919.314.6686
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL BID DOCUMENTSFacilities Management
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMP
321 4 5 6 7 8 9 10
SHEET NOTES:
SHEET OF
C
KEY PLAN
12/18/2025
A u to d e s k D o c s
/A s h e v ill e E
H R
M V
/6
-2 -7
.0
.E
.A S
H
E H
R M
.r v t
/1 /2
:5
:5
P M
47-TD103
TELECOMMUNICATIONS BASEMENT
DEMOLITION - PART CAwen Solutions Group
215 N. Payne Street, Suite 122
Alexandria, VA 22314
12.19.2025
EHRM INFRASTRUCTURE
UPGRADES BLDG 47
1100 TUNNEL ROAD
ASHEVILLE, NC 28805
637-22-700
GENERAL NOTES:
1. REFER TO 00-T001 FOR GENERAL NOTES AND LEGENDS.
2. ALL EXISTING CABLES AND INFRASTRUCTURE NOT CAT6A RATED TO BE DEMOLISHED.
3. NOT ALL DEVICES ARE SHOWN. CONTRACTOR TO VERIFY ALL DATA OUTLET LOCATIONS IN THE FIELD.
4. THE QUANTITY OF TELECOM DROPS TO BE REMOVED, INSTALLED, AND MAINTAINED IS BASED ON THE INFORMATION KNOWN AT THE TIME OF DESIGN. PRIOR TO CONSTRUCTION, TELECOM DROP LOCATIONS SHALL BE SURVEYED. ANY DISCREPANCIES SHALL
BE PROVIDED TO THE DOR IMMEDIATELY.
5. EXISTING ROUTING FOR TELECOM DROPS TO REMAIN SHALL BE MAINTAINED TO THE FULLEST EXTENT.
6. DEMOLITION DETAILS (IN NO PARTICULAR ORDER):
A. REFER TO ENLARGED PLANS FOR ADDITIONAL REQUIREMENTS.
B. CABLE CAT6 AND BELOW HORIZONTAL CABLE SHALL BE REMOVED FROM EXISTING PATCH PANELS BACK TO FINAL DATA
JACK LOCATIONS. CABLE SHALL BE REMOVED BETWEEN EXISTING SWITCH AND PATCH PANEL.
C. PATCH PANELS CURRENTLY NOT DESIGNED FOR CAT6A CABLE SHALL BE REMOVED.
D. WALL PLATES AND RJ-45 JACKS FOR WALL OUTLET BOXES FOR CAT5E, 6 AND BELOW CABLE SHALL BE REMOVED.
E. DATA RACKS SHALL BE REMOVED.
F. HORIZONTAL AND VERTICAL CABLE MANAGEMENT FOR RACKS SHALL BE REMOVED IF APPLICABLE.
G. WALL MOUNTED FIBER BOXES SHALL BE REMOVED.
H. FIBER CABLE AND ENCLOSURES SHALL BE REMOVED BACK TO SOURCE AFTER ALL NEW FIBER CONNECTIONS IN THIS
BUILDING HAVE BEEN CONNECTED. PRIOR TO DEMOLITION, COORDINATE WITH VA COR TO ENSURE ALL FIBER IS INACTIVE
BEFORE DEMOLITION.
I. EXISTING CABLE TRAY TO REMAIN.
J. COPPER PHONE PUNCH DOWN BLOCKS SHALL REMAIN UNLESS OTHERWISE NOTED.
7. DEMOLISH ALL TELECOMMUNICATIONS CABLE THAT IS NOT TERMINATED AT BOTH ENDS AT A CONNECTOR OR OTHER EQUIPMENT AND NOT IDENTIFIED 'FOR FUTURE USE' WITH A TAG. ENSURE DEMOLITION OF ABANDONED CABLE WILL NOT DISRUPT VA OPERATIONS PRIOR TO REMOVAL. WHERE DISRUPTION OF SERVICE OCCURS DUE TO DEMOLISHED CABLE, NEW
CABLE SHALL BE INSTALLED TO RESTORE THE SYSTEM AT THE CONTRACTOR'S EXPENSE.
8. PRIOR TO DEMOLITION, COORDINATE DISPOSAL WITH VA. ALL VA STANDARDS, EPA STANDARDS AND LOCAL STANDARDS MUST BE
FOLLOWED WHEN DISPOSING OF ASBESTOS EXPOSED ITEMS.
3/32" = 1'-0"
1 TELECOMMUNICATIONS BASEMENT DEMOLITION - PART C
Jinze Chen
/1 47-TD101
/1 47-TD103
/1 47-TD102
D0/4
D0/3
D1/X
D0/1
D0/2 D1/3 D0/4
D0/4
D0/4
D1/X
D2/3
D3/3D1/3 D1/3
D0/3
D0/1
D2/3
D0/3
D0/3
D0/2 D1/3
D1/2 V1
D1/2 V2
D1/2 V1
D1/2 V1
D0/2 V2
D1/2 V2
D2/2 V1
D0/2 V1
D2/2 V1
D1/2 V2
D1/2 V1
D2/2 V1
D1/2 V1D1/2
V1
D0/2 V1
D0/2 V2
D0/2 V1
D0/2 V1
D0/2 V1
D3/3 V1
D3/3 V1
D3/3 V1
D3/3 V1
D3/3 V1
D3/3 V1
D2/X
D2/2
D0/4
D0/4
D1/2
D1/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D2/2 V1
D0/1
D1/2 D1/2
D2/2 V1
D1/2 V1 D2/3
D1/2
D1/1
D2/2
D0/2 V1
D2/2 V1D2/2
V2D2/2 V1D2/2
V1
D0/2 V1
D1/2 V1
D2/2 V1
D0/2 V1
D0/2 V1
D1/2 V1
D1/2 V2
D0/2 V1
D2/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D2/2 V2
D0/2 V1
D1/2 V2
D0/2 V1
D1/2 V2
D1/2 V1
D2/2 V1
D2/2 V1
D2/2 V1D0/2
V1
D0/2 V1
DX/X
D0/3
D1/2 V1
D0/2 V1
D0/2 V1
D2/2 V1
D2/2 V1
D2/2 V1
D2/2 V1
D2/2 V1
D2/2 V1
D2/2 V1
D2/3
D1/1
D2/2 V1
D0/2 V1
D0/2 V1D0/2
V1 D0/2 V2
D2/2 V1
D2/3D2/3
DX/X
DX/X
D2/2 V1
DX/X
D2/2 V1
D2/2 V1
D2/2 V1
D1/3
D2/3
D1/3
D0/3
D1/3
D2/3
D1/2
D2/3
D1/2
D2/2
D3/3
D0/2
D0/1
D1/1
TR (EXISTING)
BB018
EXISTING TR
TR (EXPANDED)
BC118
EXPANDED TR
PUBLIC TLT.
BC115
ELEC.
BB019
STAIR #2
CORRIDOR
BB061
CLASSROOM
BC117
ELEV
STORAGE
BB020
CORRIDOR
BB016
ADA TLT
LAB & PATH
BA042
ADA TLT
LAB & PATH
BA043
CORRIDOR
BA041
STA 6
LAB & PATH
BA051
STA7
LAB & PATH
BA050
CORRIDOR
BA044
LAB & PATH
BA045
LAB & PATH
BA046
STA 10
LAB & PATH
BA047
STA 9
LAB & PATH
BA048
STA 8
LAB & PATH
BA049
STORAGE
LAB & PATH
BB014A
HAC
BB013
BULK STORES
BB014
FEMALE
HC TLT
BB007
MICRO LAB
& PATH
BB057 REFER
BB056
OFFICE
BB043
OFFICE
BB042
STORAGE ROOM
BB041
KITCHEN
BC127
ELECTRICAL
BC128
KITCHEN
BC126
STORAGE
BC125AVENDING
BC125
FOOD STORAGE
BC124
CAFETERIA CANTEEN
BC123
RECORDS
LAB & PATH
BB039
CYTOLOGY
BB038
FROZEN / GROSS
BB036
HISTOLOGY
BB037
OFFICE
BB035
OFFICE
BB034 OFFICE
BB033
OFFICE
BB030 OFFICE
BB029
OFFICE
BB028
OFFICE
& PATH
BB026
OFFICE
BB025
MALE
HC TLT
BB021
FEMALE
HC TLT
BBO22
OFFICE
BB023
OFFICE
BB027
OFFICE
BB027A
CORRIDOR
BB005
BLOOD BANK
BB058
CORRIDOR
BB040
COAG
LAB & PATH
BB044
SEND OUT
BB045
HERAROUTINE
BB046
AUTOMATED
BB047
BLOOD GAS
BB048
URINE & FECES
BB049
SPECIAL CHEMISTY
BB051
CORRIDOR
BB0124
CORRIDOR
BB015
STORAGE
BC117A
LOCKER ROOM
BB003
CORRIDOR
BB
ELEV
BE-1
ELEV
BE-2
SIM ROOM
BC121A
CONTROL
ROOM LRS
BC121
MULTI-PURPOSE ROOM
BC122
CHECK-IN
BC132
DUPLICATION
BC133
OFFICE
BC135
OFFICE
BC134
HAC FMS
BC129
STORAGE
BC130
CORRIDOR
BB060
CRAWL SPACE
CS
STAIR
1C415
OFFICE
BC103
OFFICE
BC104
MED MEDIA
BC108
CHIEF
BC107
OFFICE
BC106
OFFICE
BC105FEMALE TLT
BC114
OFFICE
BC101
OFFICE
BC102
STORAGE
BC112A
CK-IN LRS
BC111
CORRIDOR
BC-B
STORAGE
BC110A
CHIEF LIBRARY
BC109
STAIR
EXT.
CLASSROOM #2
BC110
CLASSROOM #1
BC112
ELECTRICAL
FMS
BD120
CLEAN
UTIL N&FS
BD119
TEL OPER
BC113
STAIR
1C417
OFFICE
BC119B
SECRETARY
BC119
CHIEF
BC119A
STORAGE
BC117B
LIBRARY
BC100
LINEN
BC120
ELEV
BC1
ELEV
BC2
OFFICE
BB031
TRASH CHUTE
BD127
5 5 10 15 20 25 30
3/32" = 1'-0"
FEETSCALE
PLAN
NORTH
N
FOR OFFICIAL USE ONLY
www.coffman.com
701 Corporate Center Drive, Suite 475
Raleigh, NC 27607 ph 919.314.6686
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL BID DOCUMENTSFacilities Management
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMP
321 4 5 6 7 8 9 10
SHEET NOTES:
SHEET OF
D
KEY PLAN
12/18/2025
A u to d e s k D o c s
/A s h e v ill e E
H R
M V
/6
-2 -7
.0
.E
.A S
H
E H
R M
.r v t
/1 /2
:5
:5
P M
47-TD104
TELECOMMUNICATIONS BASEMENT
DEMOLITION - PART DAwen Solutions Group
215 N. Payne Street, Suite 122
Alexandria, VA 22314
12.19.2025
EHRM INFRASTRUCTURE
UPGRADES BLDG 47
1100 TUNNEL ROAD
ASHEVILLE, NC 28805
637-22-700
GENERAL NOTES:
1. REFER TO 00-T001 FOR GENERAL NOTES AND LEGENDS.
2. ALL EXISTING CABLES AND INFRASTRUCTURE NOT CAT6A RATED TO BE DEMOLISHED.
3. NOT ALL DEVICES ARE SHOWN. CONTRACTOR TO VERIFY ALL DATA OUTLET LOCATIONS IN THE FIELD.
4. THE QUANTITY OF TELECOM DROPS TO BE REMOVED, INSTALLED, AND MAINTAINED IS BASED ON THE INFORMATION KNOWN AT THE TIME OF DESIGN. PRIOR TO CONSTRUCTION, TELECOM DROP LOCATIONS SHALL BE SURVEYED. ANY DISCREPANCIES SHALL
BE PROVIDED TO THE DOR IMMEDIATELY.
5. EXISTING ROUTING FOR TELECOM DROPS TO REMAIN SHALL BE MAINTAINED TO THE FULLEST EXTENT.
6. DEMOLITION DETAILS (IN NO PARTICULAR ORDER):
A. REFER TO ENLARGED PLANS FOR ADDITIONAL REQUIREMENTS.
B. CABLE CAT6 AND BELOW HORIZONTAL CABLE SHALL BE REMOVED FROM EXISTING PATCH PANELS BACK TO FINAL DATA
JACK LOCATIONS. CABLE SHALL BE REMOVED BETWEEN EXISTING SWITCH AND PATCH PANEL.
C. PATCH PANELS CURRENTLY NOT DESIGNED FOR CAT6A CABLE SHALL BE REMOVED.
D. WALL PLATES AND RJ-45 JACKS FOR WALL OUTLET BOXES FOR CAT5E, 6 AND BELOW CABLE SHALL BE REMOVED.
E. DATA RACKS SHALL BE REMOVED.
F. HORIZONTAL AND VERTICAL CABLE MANAGEMENT FOR RACKS SHALL BE REMOVED IF APPLICABLE.
G. WALL MOUNTED FIBER BOXES SHALL BE REMOVED.
H. FIBER CABLE AND ENCLOSURES SHALL BE REMOVED BACK TO SOURCE AFTER ALL NEW FIBER CONNECTIONS IN THIS
BUILDING HAVE BEEN CONNECTED. PRIOR TO DEMOLITION, COORDINATE WITH VA COR TO ENSURE ALL FIBER IS INACTIVE
BEFORE DEMOLITION.
I. EXISTING CABLE TRAY TO REMAIN.
J. COPPER PHONE PUNCH DOWN BLOCKS SHALL REMAIN UNLESS OTHERWISE NOTED.
7. DEMOLISH ALL TELECOMMUNICATIONS CABLE THAT IS NOT TERMINATED AT BOTH ENDS AT A CONNECTOR OR OTHER EQUIPMENT AND NOT IDENTIFIED 'FOR FUTURE USE' WITH A TAG. ENSURE DEMOLITION OF ABANDONED CABLE WILL NOT DISRUPT VA OPERATIONS PRIOR TO REMOVAL. WHERE DISRUPTION OF SERVICE OCCURS DUE TO DEMOLISHED CABLE, NEW
CABLE SHALL BE INSTALLED TO RESTORE THE SYSTEM AT THE CONTRACTOR'S EXPENSE.
8. PRIOR TO DEMOLITION, COORDINATE DISPOSAL WITH VA. ALL VA STANDARDS, EPA STANDARDS AND LOCAL STANDARDS MUST BE
FOLLOWED WHEN DISPOSING OF ASBESTOS EXPOSED ITEMS.
3/32" = 1'-0"
1 TELECOMMUNICATIONS BASEMENT DEMOLITION - PART D
Jinze Chen
47-TD402
47-TD402
47-TD402
47-TD402
47-TD402
47-TD402
47-TD402
47-TD402
47-TD402
47-TD402
PLAN
NORTH
N
FOR OFFICIAL USE ONLY
www.coffman.com
701 Corporate Center Drive, Suite 475
Raleigh, NC 27607 ph 919.314.6686
20 20 40
1" = 20'-0"
FEETSCALE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL BID DOCUMENTSFacilities Management
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMP
321 4 5 6 7 8 9 10
SHEET NOTES:
SHEET OF
KEY PLAN
12/18/2025
A u to d e s k D o c s
/A s h e v ill e E
H R
M V
/6
-2 -7
.0
.E
.A S
H
E H
R M
.r v t
/1 /2
:5
:0
P M
47-TD110
TELECOMMUNICATIONS 1ST FLOOR
DEMOLITION - OVERALLAwen Solutions Group
215 N. Payne Street, Suite 122
Alexandria, VA 22314
12.19.2025
EHRM INFRASTRUCTURE
UPGRADES BLDG 47
1100 TUNNEL ROAD
ASHEVILLE, NC 28805
637-22-700
GENERAL NOTES:
1. REFER TO 00-T001 FOR GENERAL NOTES AND LEGENDS.
2. ALL EXISTING CABLES AND INFRASTRUCTURE NOT CAT6A RATED TO BE DEMOLISHED.
3. NOT ALL DEVICES ARE SHOWN. CONTRACTOR TO VERIFY ALL DATA OUTLET LOCATIONS IN THE FIELD.
4. THE QUANTITY OF TELECOM DROPS TO BE REMOVED, INSTALLED, AND MAINTAINED IS BASED ON THE INFORMATION KNOWN AT THE TIME OF DESIGN. PRIOR TO CONSTRUCTION, TELECOM DROP LOCATIONS SHALL BE SURVEYED. ANY DISCREPANCIES SHALL
BE PROVIDED TO THE DOR IMMEDIATELY.
5. EXISTING ROUTING FOR TELECOM DROPS TO REMAIN SHALL BE MAINTAINED TO THE FULLEST EXTENT.
6. DEMOLITION DETAILS (IN NO PARTICULAR ORDER):
A. REFER TO ENLARGED PLANS FOR ADDITIONAL REQUIREMENTS.
B. CABLE CAT6 AND BELOW HORIZONTAL CABLE SHALL BE REMOVED FROM EXISTING PATCH PANELS BACK TO FINAL DATA
JACK LOCATIONS. CABLE SHALL BE REMOVED BETWEEN EXISTING SWITCH AND PATCH PANEL.
C. PATCH PANELS CURRENTLY NOT DESIGNED FOR CAT6A CABLE SHALL BE REMOVED.
D. WALL PLATES AND RJ-45 JACKS FOR WALL OUTLET BOXES FOR CAT5E, 6 AND BELOW CABLE SHALL BE REMOVED.
E. DATA RACKS SHALL BE REMOVED.
F. HORIZONTAL AND VERTICAL CABLE MANAGEMENT FOR RACKS SHALL BE REMOVED IF APPLICABLE.
G. WALL MOUNTED FIBER BOXES SHALL BE REMOVED.
H. FIBER CABLE AND ENCLOSURES SHALL BE REMOVED BACK TO SOURCE AFTER ALL NEW FIBER CONNECTIONS IN THIS
BUILDING HAVE BEEN CONNECTED. PRIOR TO DEMOLITION, COORDINATE WITH VA COR TO ENSURE ALL FIBER IS INACTIVE
BEFORE DEMOLITION.
I. EXISTING CABLE TRAY TO REMAIN.
J. COPPER PHONE PUNCH DOWN BLOCKS SHALL REMAIN UNLESS OTHERWISE NOTED.
7. DEMOLISH ALL TELECOMMUNICATIONS CABLE THAT IS NOT TERMINATED AT BOTH ENDS AT A CONNECTOR OR OTHER EQUIPMENT AND NOT IDENTIFIED 'FOR FUTURE USE' WITH A TAG. ENSURE DEMOLITION OF ABANDONED CABLE WILL NOT DISRUPT VA OPERATIONS PRIOR TO REMOVAL. WHERE DISRUPTION OF SERVICE OCCURS DUE TO DEMOLISHED CABLE, NEW CABLE SHALL
BE INSTALLED TO RESTORE THE SYSTEM AT THE CONTRACTOR'S EXPENSE.
8. PRIOR TO DEMOLITION, COORDINATE DISPOSAL WITH VA. ALL VA STANDARDS, EPA STANDARDS AND LOCAL STANDARDS MUST
BE FOLLOWED WHEN DISPOSING OF ASBESTOS EXPOSED ITEMS.
1" = 20'-0"
1 TELECOMMUNICATIONS 1ST FLOOR DEMOLITION - OVERALL
Jinze Chen
D2/2 V1 D1/2
V1
D3/4
D2/2 V1 D1/1 D1/1
D2/2 V2
D0/2 V2
D1/2 V2
D1/2 V2D0/2
V1
D0/1 V2
D0/1
D2/2 V2
D2/2 V2
D3/4 D0/4 D0/4
D1/2 V2
D1/3
D2/2
DX/X
VX
D1/2 V1
D2/3 V1
D2/2 V2
D1/2 V1
D0/1 V1
D1/1 D1/1 V1
D0/1D0/1
D3/4
D2/3
D0/2 V2D0/2
V1
D0/2 V1
D0/2 V1
D0/1
D2/2 V1
D2/4
D1/1
D2/2 V2
D0/1
D1/2 V1D0/2
V1
D1/2 V1
D2/2 V1
D1/2 V2D1/3
V1
D0/2 V2
D1/2 V1
D1/2 V1D0/2
V2
D1/2 V1
D1/1
D0/1
D3/3
D0/3
D2/2 V2
D0/2 V1
D0/2 V2
D2/2 V2
D0/2 V2
D0/2 V2
D2/3
D0/1
D2/2 V1
D2/2 V1
D1/2 V2
D1/2
D2/3 D3/4
D0/1
D1/2 V2
D1/2
D3/3 V1
D1/1
D0/2 V1
D0/1 V1
D1/1 D1/1 D1/1
D1/2 V1
D1/2 V1
D1/2 V1
D0/2 V2 D1/2
V1
D1/X
D1/3
D1/1
D1/2 V1 D0/1
D0/2 V1
D0/1
D0/1 D0/1
D2/2 D1/1
D0/2 D0/2 V2
D1/2 V2
D1/2 V2
D0/2 V2
D0/2 V2
D2/3
D1/3
D2/2 V1
D1/2 V1
D1/2 V1
D0/2 V1
D1/3
D1/1 D1/1 D1/1
D3/4
D2/2 V1D1/2
V1
D1/2 V2
D1/2 V1
D1/2 V1
D0/3
D0/4
D1/3
D0/4
D1/3
D1/2 V1
D1/3
D1/3
D2/2 V1
D1/3 D1/1
D0/3
D2/2 V1
D2/2 V1
D2/2 V1
D2/3
D0/2 V1
D2/2 V1
D2/2 V1
D0/2 V2
D2/2 V2
D1/2 V2
D1/2 V2
D1/2 V2
D2/2 V1
D2/2 V1
D1/2 V2
D1/2 V2
D1/2 V2
D1/2 V1
D1/1
D1/1
D2/4
D1/1
D1/1D0/1D0/1
D1/1 D2/3
D0/1 D1/3
D1/1
D1/3
D2/3
D1/X
D0/1
D1/3 V2
D1/2D2/2D1/2
D1/2 V2 D0/3
D0/1
D1/1 D1/3
D1/3 D2/2 V2
D1/2 V2
D2/2 V2
D1/2 V2 D1/2
V2
D1/1
/1 47-TD112
/1 47-TD113
/1 47-TD114
D1/4
D1/2 V2
D1/2
TR (DECOMMISSIONED)
1G131A
TR TO BE DECOMMISSIONED
OFFICE
1G131
OFFICE
1H113A
TR (NEW)
1H113
NEW TR
OFFICE
1H112
OFFICE
1H111
TLT
1D141A
TR (DECOMMISSIONED)
1D139
TR TO BE DECOMMISSIONED
TR (DECOMMISSIONED)
1C167
TR TO BE DECOMMISSIONED
TR (NEW)
1D144
NEW TR
CORRIDOR
1D148
MED SUPPLIES
1D143
RADIOLOGIST
1D145
ENT EXAM
1G106
FIRE UTIL
N/A
AUD EXAM
1G107A
AUD EXAM
1G107B
AUD INSTR CALIB
1G108
HC TLT
AUDIO
1G108A
PHONE
UTIL FMS
1D152A
ELEC
UTIL FMS
1D152B
AUD EXAM
1G109
TLT
1G105A
TLT
1G106A
ENT EXAM
1G105
BOOTH AUDIO
1G118A CONTROL AUDIO
1G118
CORRIDOR
1D163
ENT EXAM
1G104
ENT EXAM
1G103
BOOTH AUDIO
1G117A
CONTROL AUDIO
1G117
CONTROL AUDIO
1G116
BOOTH AUDIO
1G116A
AUDIO
RECEPTION SURGERY
1G102
AUD OFFICE
1G115
ENT EXAM
1G119
AUD EXAM
1G114
AUD EXAM
1G113
AUD EXAM
1G112
AUD EXAM
1G111
AUD EXAM
1G110 CPE RESIDENTS
1G100B
AUDIO WAITING
1G101
CORRIDOR
1D170
CORRIDOR
1D151 MAIN CHAPEL
1C148
OFFICE
1G100A
STORE ROOM
1D157
OFFICE
1D156
OFFICE
1G155
C/T TA CTL
1G154
C/T TA SCAN
1D153
STORAGE
1D152
ENT EXAM
1G120
ENT EXAM
1G121
ENT EXAM
1G122
EXAM/OFFICE
1G123
OFFICE
1G132
ELECT UTIL
TG133D
PHONE UTIL
TG133C
ELEC UTIL
1G133B
WHEEL CHAIR SHOPS
1C153 MALE TLT
1G135
HAC
1G133A
FML TLT
1G136
OFFICE
1H110
OFFICE
1C165
OFFICE
1D147
FIRE EQUIP
1C166
OFFICE
1D146
PHYSICIAN
1C168
ULTRASOUND
1D142
C/T PQ SCANNER
1D167
UTIL
1D140 OFFICE
1D141 OFFICE
1D137 OFFICE
1D136 OFFICE
1D135
OFFICE
1D134
DIV/ANGIO
1D169
STAFF LOUNGE
1D114
NUC MED CAMERA 3
1D120
ULTRASOUND
1C172
UPTAKE ROOM
1D122
FLUORO RM 3
1D164
RADIOGRAPHIC RM 2
1C173
C/T CONTROL
1D168
NM READ/PROC
1D121
RADIOGRAPHIC
1D113
ELEC EQUIP
1D111
LOCKERS
1D123
DOSE ADMIN
1D115
OFFICE
1D125
BREAK RM
1D126
OFFICE
1D124
TOILET
1D117
FLUOROSCOPIC RM 4
1D166
DRESS ROOM
1D165
TLT
1D165A
TLT
1D165B
OFFICE
1D150
ELEC
EQUIP
TD149
CORRIDOR
1C175
CONF RM
1D104
RECEPT / WAITING
1D105
TOILET
1D103
MRI SCANNER
1D127
TOILET
1D101
NUC MED CAMERA 1
1D118
RADIO PHARMACY
1D116
EXAM
1J118A
IV CONSENT
1D110
NUC MED CAMERA 2
1D119
HAC
1D112
DRESSING RM
1D108
OFFICE
1D107
OFFICE
1D109
WAITING
1D106
RADIO
GRAPHIC
1D113A
CORRIDOR
1C176
CORRIDOR
1D133
DECAY CLOSET
1D116ASTORAGE
1D165C
OFFICE
1H156
OFFICE
1H159
MINOR PRO
1C178
INVENTORY
1H157
EXAM RM
1C179
SPD
1C180
STAFF LOCKER
1C181
TOILET
1C160A
NO ROOM
NAME
1C189
RADIOGRAPHIC RM
1D159
OFFICE
1D158
STOR.
1H158
PHYSICIAN
1J155
FIRE EQUIP
1C192
ELEC
1D132
ELEC EQUIP
1D131
PHYSICIAN
1J156
RADIOGRAPHIC RM
1D160
RADIOGRAPHIC RM 1
1D161
RECEPT
1C198
WAITING
1C199
WAITING
1D102
MRI COMPUTER RM
1D128A
OFFICE
1C200
CONTROL
1C201
TLT
1C202
D.R.
1C203
CYSTO
1C204
CONTROL
1C205
HAC
1C118
STAIR
1C206
TLT
1D162A
TECH IMAGING WORK ROOM
1D171
DRESSING RM
1D162
TLT
1C210
STRESS TEST
1K136
EXAM
1K133
EXAM ROOM
1C120A
CAST RM
1C120
MRI 2 SCANNER
1D129
NURSE
1C221
SOCIAL WORKER
1C222
CHAPLAIN
1C223
MRI 2 COMPUTER RM
1D130
CHIEF NURSE
1C224
EXAM RM
1J121
EXAM RM
1J120
EXAM RM
1J119
EXAM RM
1J122
PHY EXTEND
1J157
EC
TC158C
CORRIDOR
1C284
CORRIDOR
1C285
MRI CONTROL
1D128
CORRIDOR
1B240
ELEC UTIL
1D174
STAIR
1C289
ELECTRICAL
1C292
SWITCHGEAR
1C293
CORRIDOR
1C296
Room
1G131NN
Room
1G131OO
5 5 10 15 20 25 30
3/32" = 1'-0"
FEETSCALE
PLAN
NORTH
N
FOR OFFICIAL USE ONLY
www.coffman.com
701 Corporate Center Drive, Suite 475
Raleigh, NC 27607 ph 919.314.6686
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL BID DOCUMENTSFacilities Management
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMP
321 4 5 6 7 8 9 10
SHEET NOTES:
SHEET OF
A
KEY PLAN
12/18/2025
A u to d e s k D o c s
/A s h e v ill e E
H R
M V
/6
-2 -7
.0
.E
.A S
H
E H
R M
.r v t
/1 /2
:5
:0
P M
47-TD111
TELECOMMUNICATIONS 1ST FLOOR
DEMOLITION - PART AAwen Solutions Group
215 N. Payne Street, Suite 122
Alexandria, VA 22314
12.19.2025
EHRM INFRASTRUCTURE
UPGRADES BLDG 47
1100 TUNNEL ROAD
ASHEVILLE, NC 28805
637-22-700
GENERAL NOTES:
1. REFER TO 00-T001 FOR GENERAL NOTES AND LEGENDS.
2. ALL EXISTING CABLES AND INFRASTRUCTURE NOT CAT6A RATED TO BE DEMOLISHED.
3. NOT ALL DEVICES ARE SHOWN. CONTRACTOR TO VERIFY ALL DATA OUTLET LOCATIONS IN THE FIELD.
4. THE QUANTITY OF TELECOM DROPS TO BE REMOVED, INSTALLED, AND MAINTAINED IS BASED ON THE INFORMATION KNOWN AT THE TIME OF DESIGN. PRIOR TO CONSTRUCTION, TELECOM DROP LOCATIONS SHALL BE SURVEYED. ANY DISCREPANCIES SHALL
BE PROVIDED TO THE DOR IMMEDIATELY.
5. EXISTING ROUTING FOR TELECOM DROPS TO REMAIN SHALL BE MAINTAINED TO THE FULLEST EXTENT.
6. DEMOLITION DETAILS (IN NO PARTICULAR ORDER):
A. REFER TO ENLARGED PLANS FOR ADDITIONAL REQUIREMENTS.
B. CABLE CAT6 AND BELOW HORIZONTAL CABLE SHALL BE REMOVED FROM EXISTING PATCH PANELS BACK TO FINAL DATA
JACK LOCATIONS. CABLE SHALL BE REMOVED BETWEEN EXISTING SWITCH AND PATCH PANEL.
C. PATCH PANELS CURRENTLY NOT DESIGNED FOR CAT6A CABLE SHALL BE REMOVED.
D. WALL PLATES AND RJ-45 JACKS FOR WALL OUTLET BOXES FOR CAT5E, 6 AND BELOW CABLE SHALL BE REMOVED.
E. DATA RACKS SHALL BE REMOVED.
F. HORIZONTAL AND VERTICAL CABLE MANAGEMENT FOR RACKS SHALL BE REMOVED IF APPLICABLE.
G. WALL MOUNTED FIBER BOXES SHALL BE REMOVED.
H. FIBER CABLE AND ENCLOSURES SHALL BE REMOVED BACK TO SOURCE AFTER ALL NEW FIBER CONNECTIONS IN THIS
BUILDING HAVE BEEN CONNECTED. PRIOR TO DEMOLITION, COORDINATE WITH VA COR TO ENSURE ALL FIBER IS INACTIVE
BEFORE DEMOLITION.
I. EXISTING CABLE TRAY TO REMAIN.
J. COPPER PHONE PUNCH DOWN BLOCKS SHALL REMAIN UNLESS OTHERWISE NOTED.
7. DEMOLISH ALL TELECOMMUNICATIONS CABLE THAT IS NOT TERMINATED AT BOTH ENDS AT A CONNECTOR OR OTHER EQUIPMENT AND NOT IDENTIFIED 'FOR FUTURE USE' WITH A TAG. ENSURE DEMOLITION OF ABANDONED CABLE WILL NOT DISRUPT VA OPERATIONS PRIOR TO REMOVAL. WHERE DISRUPTION OF SERVICE OCCURS DUE TO DEMOLISHED CABLE, NEW CABLE SHALL
BE INSTALLED TO RESTORE THE SYSTEM AT THE CONTRACTOR'S EXPENSE.
8. PRIOR TO DEMOLITION, COORDINATE DISPOSAL WITH VA. ALL VA STANDARDS, EPA STANDARDS AND LOCAL STANDARDS MUST
BE FOLLOWED WHEN DISPOSING OF ASBESTOS EXPOSED ITEMS.
3/32" = 1'-0"
1 TELECOMMUNICATIONS 1ST FLOOR DEMOLITION - PART A
Jinze Chen
/1 47-TD111 /1 47-TD114
D1/1
D0/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D0/2 V1
D2/2 V1
D0/2 V1
D0/2 V1
D0/2 V1
D0/2 V1
D1/2 V1
D0/3 V1
D2/2
D0/2 V1
D0/2 V1
D0/2 V1
D1/2 V1
D2/2 V1
D0/2 V1
D0/2 V1
D0/2 V1
D2/2 V1
D0/2 V1
D1/1
D1/2 V1D0/2
V1
D0/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D1/3
D1/1
D1/2 V1
D2/2 V1
D0/2
D1/2
D1/2
D1/2
D1/3 V1
D0/1
D0/1
D1/1
D2/2 V1
D0/2 V1
D1/2 V2
D1/2 V1
D1/3
D1/2 V1
D0/2 V1
D0/1
D0/1
D0/1
D2/2 V1
D0/1
D0/1
D1/2 V1
D1/2 V1
D0/2 V1
D0/2 V1
D1/1
D1/1
D1/2 V1
D1/2 V1
D2/3
D2/2 V2
D1/2 V1
D0/2 V1
D0/1
D1/1
D1/2 V2
D1/1
D1/3 D1/3 V1
D1/2
D0/2 V2
D0/2 V2
D1/1
D2/2 V1
D2/2 V2
D2/3
D1/2 V2
D1/1
D2/3
D2/2 V2
D0/1
D0/2 V1
D1/2 V1
D0/1
D0/2 V1
D1/2 V1
D1/2 V1
D2/2 V2
D0/2 V1D1/2
V1D0/2 V1
D0/2 V1
D1/2 V1
D2/2 V2
D1/2 D0/2
D0/3
D0/2
D0/2
D1/1 V2
D1/1
D1/1
D1/1 V1
D2/2 V2
D1/1
D1/2 V2
D2/2
D1/1
D1/2 V2
D2/2 V2D0/2
D1/3 D1/3 V1
D1/3
D0/3
D1/3 V1
D1/3 D0/3 V1
D1/3D1/2 V1
D0/2 V1
D1/2 V1
D2/2 V1
D2/2 V1
D1/2 V1
D1/2 V1
D2/2 V2
D0/2 V1
D0/1 D1/2 V1
D1/1
D1/1
D1/1
D1/1
D0/3
D2/2 V2
D4/4
D1/2 V1
D0/3
D0/3
D1/2 V1
D1/2 V1
D0/2 V1
D1/2 V2
D1/2 V2
D2/2 V2
D1/2 V2
D0/1D1/1
D1/2 V2
D2/2 V1
D2/2 V1
D2/2 V1
D2/2 V1
D1/2 V1
D0/2 V1
D0/2 V1
D1/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D1/2 V1
D0/2 V1
D0/2 V1
D1/2 V1
D2/2 V1
D0/3
D2/3
D1/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D1/2 V1
D0/2 V1 D1/2
V1
D1/2 V1
D2/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D0/2 V1
D1/2 V1 D1/2
V1
D0/2 V1D0/2
V1 D1/2 V1
D0/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D0/2 V1
D1/2 V1
D1/2
D1/2 V1
D0/2 V1
D0/2 V1
D2/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D0/2 V1
D1/2 V1
D0/1
D1/2 V1
D0/2 V1
D1/1
D0/2 V1
D1/2 V1
D1/2 V1
D0/2 V1
D0/2 V1
D0/2 V1
D1/3 V1
D1/2 V1 D0/2
V1
D1/2 V1D1/2
V1
D3/3 D2/2 V1 D0/3
D1/2 V1
D2/2 V1D1/2
V1 D0/3
D0/1D2/2
D0/2 D0/2 D0/2
D1/2
D2/3 D1/3 D2/3
D1/2 V1
D0/3
D2/2 V2
D2/2 V2
D1/3
D1/3
V2
D1/2
D1/2 V1 D1/1
D1/3
D0/3
D1/3
D0/3
D0/3
D1/3
D1/3
D1/3
D0/3
D0/3
D1/1 V1
D2/3
D0/2 V1
D2/2 V1
D2/3D2/3D2/3 D0/1 V1
D1/4
D2/4
D2/3 V1
D2/3 V1
D2/3 V1
D2/3 V1
D0/4
D0/3
D1/4
D2/3
D0/2 D1/2 V1
D2/2 V1
D1/2 V1
D2/2 V1
D1/2 V1
D0/2
D1/1
D1/2 V1
D0/2
D1/1
D1/2 V1
D1/1
D0/2
D1/2
D0/2
D1/1
D1/3
D2/4 D1/3 D0/2 D0/3
D0/2
D1/3
D2/3
D1/2 V1
D0/2 V1
D1/2 V1
D3/3
D2/3
D1/1
D1/1
D0/3
D0/2
D2/3
D0/3
D2/2 V1
D0/2 V1
D2/2 V1
D1/2 V1
D1/2 V1
D0/2 V1
D2/2 V1
D2/4
D0/2 V1
D1/2 V1
D2/2
D0/2 D1/4
D0/1
D1/2 V1
D0/2 D1/1 D1/2 V1
D0/2 D1/1
D1/1
D0/2 V1D1/2
V1
D1/2 V2
D1/2
D1/3
D1/2 V1
D1/2 V2
TR (DECOMMISSIONED)
1A163
TR TO BE DECOMMISSIONED
ELEC
1A162
ELEC
1A136
TR (EXISTING)
1A137
EXISTING TR
STAIR
OFFICE
1A135 CORRIDOR
1A134
EXAM
1J118A
PHYSICIAN
1J155
PHYSICIAN
1J154
PHYSICIAN
1J153
STORAGE
1K136B
OFFICE
1K136A
STRESS TEST
1K136
EXAM
1K135 CONSULT
1K104
CASHIER
1K137
TRAVEL CK
1K139
WAITING
1K140
OFFICE
1K138
NURSE
1C221
SOCIAL WORKER
1C222
CHAPLAIN
1C223
EXAM
1J112
EXAM
1J111
CHIEF NURSE
1C224
EXAM
1J110
EXAM
1J167
EXAM
1J118C
EXAM
1J105
CLEAN
UTILITY
1J115
HAS SUPER
1J106
MED RM
1J116
FML TLT
1J107
MALE TLT
1J108
STAFF TLT
1J117
EXAM RM
1J121
EXAM RM
1J120
EXAM RM
1J119
EXAM RM
1J122
PHY EXTEND
1J157
SOILDED UTL
1J126
EXAM RM
1J125
EXAM
1J124
EXAM
1J123
EXAM
1J130
EXAM
1J129
EXAM RM
1J128
EXAM
1J127 EXAM RM
1J134
EXAM RM
1J135
EXAM RM
1J136
EXAM RM
1J133
EXAM RM
1J132
EXAM RM
1J137
EXAM
1J131
EXAM
1J138
PHYSICIAN
1J152
PHYSICIAN
1J151
PHYSICIAN
1J150
PHYSICIAN
1J149
AA ACOS
1J148
PHYSICIAN
1J147
PHYSICIAN
1J146
EXAM RM
1J139
EXAM RM
1J140
EXAM
1J141
VESTIBULE
1J145 CHIEF
1J144
EXAM
1J143
EXAM RM
1J142
TLT
1J142A
TLT
1J210A
EXAM/PROCEDURE
1J210
EXAM
1J209
OFFICE
1J207
OFFICE
1J208
OFFICE
1A173
SOILED LINEN
1A173A
OFFICE
1A172
EXAM
1J205
OFFICE
1A171
OFFICE
1J203
OFFICE
1A170
EC
TC158C
PHONE
TC158B
EC
TC158A
EC
TC158D
PRIME
CARE CORR
1C225
RECEPTION
1J202
CONF ROOM
1J201 OFFICE
1A169
TLT
1J205A
CLST
1J204
TLT
1J209A
STOR/SWING SPACE
1A215
MECH CHASE
1C226
RECEPTIONIST
1A165
OFFICE
1A166
OFFICE
1A167
MECH CHASE
1C227
OFFICE
1A168
OFFICE
1B176
EXAM ROOM
1A161
PATIENT SAFETY
1C230
OBS 1
1A201
OBS 2
1A202
EXAM ROOM
1A160
RAD
1A217
MED
1A214
CORRIDOR
C1C3
CORRIDOR
C1C4
CORRIDOR
C1C5
TLT
1J143A
CORRIDOR
C1C7
RECEPTION
1J104
WAITING
1J103
BREAKROOM
1C231
OFFICE
1B175
VESTIBULE
1B177
MECH CHASE
1C241
EXAM ROOM
1B104 EXAM ROOM
1C246
EXAM ROOM
1C247
EXAM ROOM
1C248
EXAM
1C249
HC TLT
1B107A
WORK ROOM
1C252
VESTIBULE
1C253
FML TLT
1K101
MALE TLT
1A179
OFFICE
1A142
OFFICE
1C255
OFFICE
1C256
OFFICE
1A145
OFFICE
1C257
OFFICE
1C258
OFFICE
1C259
OFFICE
1A126
OFFICE
1A148
OFFICE
1A147
OFFICE
1A146
AOD
1A125
OFFICE
1A122
OFFICE
1A123
MALE HC TLT
1A124
EXAM
1A118
NURSES STATION
1J114
NURSE STN
1J206
WAITING ROOM
1J200
EXAM
1J113
WAITING
1J100
WAITING
1K100
FML TLT
1J101
VESTIBULE
1C260
GALLERY
1A102
LOBBY
1C261
GALLERY
1C262
HC TLT
1A109 OFFICE
1A110A
OFFICE
1A111
CONF ROOM
1A112
EXAM
1A113
EXAM
1A117
EXAM
1A116
EXAM
1A115
SUPPLY
1A114
VEST
1A127
OBS 5
1A205
OBS 3
1A203
RECEPT
1A108A
WAITING
1C267
CORRIDOR
1C268
CORRIDOR
1C269
PHARM
1A130
OFFICE
1A131
OFFICE
1A132
OFFICE
1C270
OFFICE
1C271
OBS 8
1A208MED
1A213
HC TLT
SHOWER
1A223NURSE MGR
1A222
TLT/SHOWER
1A221 HAC
1A220
SOILED
LINEN
1A219
BREAKROOM
1A218
CLEAN LINEN
1A216
SAFE
1A218A
NURSE STN #1
1A200
RECEPTION/CONTROL
1C275
WAITING
1C276
CORRIDOR
1A161A
HAC
1A119
OBS 7
1A207
ANTE RM
1A208A
CORRIDOR
1A149
CORRIDOR
1A121
CORRIDOR
1C277
CHASE
1C278
CORRIDOR
1A151
CHASE
1C279
OBS 11
1A211
OBS 10
1A210
OBS 9
1A209
STAFF
1A212
FEMALE
1A230
ELEV LOBBY
1A106
CORRIDOR
1C283
STAIR
MAIN
OBS 4
1A204
OBS 6
1A206
ALCOVE 3
1A240B
WAITING
1K103
CORRIDOR
C1C1
CORRIDOR
C1C2
CORRIDOR
C1C6
NO RM NAME
1C286
EXAM/SECURITY
1A224
CORRIDOR
1A241
CORRIDOR
1A240
CORRIDOR
1A236
CORRIDOR
1A239
CORRIDOR
1A238
ALCOVE 1
1A239A
HAC
1J158
WAITING
1A232
VEST
1A233
WAITING
1C290
VEST
1A235
CORRIDOR
1A237
LIFE SUPPORT
1A226
NO RM NAME
1C291
EXAM
1A234 RECEPTION
1A228
MALE
1A231
NURSES STN 2
1A227
LOBBY/VEND
1A229
Room
1G131MM
CORRIDOR
1C294
CORRIDOR
1C295
5 5 10 15 20 25 30
3/32" = 1'-0"
FEETSCALE
PLAN
NORTH
N
FOR OFFICIAL USE ONLY
www.coffman.com
701 Corporate Center Drive, Suite 475
Raleigh, NC 27607 ph 919.314.6686
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL BID DOCUMENTSFacilities Management
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMP
321 4 5 6 7 8 9 10
SHEET NOTES:
SHEET OF
B
KEY PLAN
12/18/2025
A u to d e s k D o c s
/A s h e v ill e E
H R
M V
/6
-2 -7
.0
.E
.A S
H
E H
R M
.r v t
/1 /2
:5
:1
P M
47-TD112
TELECOMMUNICATIONS 1ST FLOOR
DEMOLITION - PART BAwen Solutions Group
215 N. Payne Street, Suite 122
Alexandria, VA 22314
12.19.2025
EHRM INFRASTRUCTURE
UPGRADES BLDG 47
1100 TUNNEL ROAD
ASHEVILLE, NC 28805
637-22-700
GENERAL NOTES:
1. REFER TO 00-T001 FOR GENERAL NOTES AND LEGENDS.
2. ALL EXISTING CABLES AND INFRASTRUCTURE NOT CAT6A RATED TO BE DEMOLISHED.
3. NOT ALL DEVICES ARE SHOWN. CONTRACTOR TO VERIFY ALL DATA OUTLET LOCATIONS IN THE FIELD.
4. THE QUANTITY OF TELECOM DROPS TO BE REMOVED, INSTALLED, AND MAINTAINED IS BASED ON THE INFORMATION KNOWN AT THE TIME OF DESIGN. PRIOR TO CONSTRUCTION, TELECOM DROP LOCATIONS SHALL BE SURVEYED. ANY DISCREPANCIES SHALL
BE PROVIDED TO THE DOR IMMEDIATELY.
5. EXISTING ROUTING FOR TELECOM DROPS TO REMAIN SHALL BE MAINTAINED TO THE FULLEST EXTENT.
6. DEMOLITION DETAILS (IN NO PARTICULAR ORDER):
A. REFER TO ENLARGED PLANS FOR ADDITIONAL REQUIREMENTS.
B. CABLE CAT6 AND BELOW HORIZONTAL CABLE SHALL BE REMOVED FROM EXISTING PATCH PANELS BACK TO FINAL DATA
JACK LOCATIONS. CABLE SHALL BE REMOVED BETWEEN EXISTING SWITCH AND PATCH PANEL.
C. PATCH PANELS CURRENTLY NOT DESIGNED FOR CAT6A CABLE SHALL BE REMOVED.
D. WALL PLATES AND RJ-45 JACKS FOR WALL OUTLET BOXES FOR CAT5E, 6 AND BELOW CABLE SHALL BE REMOVED.
E. DATA RACKS SHALL BE REMOVED.
F. HORIZONTAL AND VERTICAL CABLE MANAGEMENT FOR RACKS SHALL BE REMOVED IF APPLICABLE.
G. WALL MOUNTED FIBER BOXES SHALL BE REMOVED.
H. FIBER CABLE AND ENCLOSURES SHALL BE REMOVED BACK TO SOURCE AFTER ALL NEW FIBER CONNECTIONS IN THIS
BUILDING HAVE BEEN CONNECTED. PRIOR TO DEMOLITION, COORDINATE WITH VA COR TO ENSURE ALL FIBER IS INACTIVE
BEFORE DEMOLITION.
I. EXISTING CABLE TRAY TO REMAIN.
J. COPPER PHONE PUNCH DOWN BLOCKS SHALL REMAIN UNLESS OTHERWISE NOTED.
7. DEMOLISH ALL TELECOMMUNICATIONS CABLE THAT IS NOT TERMINATED AT BOTH ENDS AT A CONNECTOR OR OTHER EQUIPMENT AND NOT IDENTIFIED 'FOR FUTURE USE' WITH A TAG. ENSURE DEMOLITION OF ABANDONED CABLE WILL NOT DISRUPT VA OPERATIONS PRIOR TO REMOVAL. WHERE DISRUPTION OF SERVICE OCCURS DUE TO DEMOLISHED CABLE, NEW CABLE SHALL
BE INSTALLED TO RESTORE THE SYSTEM AT THE CONTRACTOR'S EXPENSE.
8. PRIOR TO DEMOLITION, COORDINATE DISPOSAL WITH VA. ALL VA STANDARDS, EPA STANDARDS AND LOCAL STANDARDS MUST
BE FOLLOWED WHEN DISPOSING OF ASBESTOS EXPOSED ITEMS.
3/32" = 1'-0"
1 TELECOMMUNICATIONS 1ST FLOOR DEMOLITION - PART B
Jinze Chen
/1 47-TD111 /1 47-TN114
/1 47-TN112
D0/1 V1D1/2
V1
D1/2
D1/1
D0/1
D1/1
D0/1
D1/3
D2/3 D3/3 D2/3 D3/3
D1/1
D2/2 V1
D0/1
D1/2 V1
D1/2 V1
D0/2 V2
D1/2 V1
D0/2 V1
D1/1
D2/3 V3
D1/4
D2/2 D2/2 D1/2
D3/3 V1
D2/2 V2
D1/2 V1
D2/2 V1
D2/2 V1
D2/2 V1
D1/2 V1
D1/2 V1
D0/1
D4/6
D1/2 V1
D1/2 V1 D2/2
V1
D1/2 V1
D1/2 V2
D1/2 V1
D1/2
D2/2 V1
D0/1
D2/2
D2/2 V1
D1/2 V1
D1/2 V1
D0/3 D2/2 V1
D2/2 V1
D2/2 V1
D0/2
D1/2
D1/2 V1
D1/2 V1 D1/X
D1/3 D0/3 D2/2
D2/2 V1
D8/8
D2/2 V1
D1/1 V1
D1/2 V1
D1/2 V1
D0/2 V1
D1/2 V2
D0/2 V1 D0/1
V1
D0/1 V1
D1/1 V1
D0/2 V1
D0/2 V1
D1/2 V1
D0/2 V2
D0/3
D0/3
D0/3D0/3 D0/3 D0/3
D1/2 V1
D0/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D0/3 D0/3
D1/2 V1
D2/2 V1
D1/2 V2
D0/3
D2/3 D1/3
D0/2 V1
D0/3
D0/2 V2
D1/2 V2
D0/2 V2
D1/2 V2
D2/2 V2
D1/1
D0/2 D0/2 V2D1/2
V2
D1/2 V2
D1/2 V2
D1/2 V2 D0/1
D1/2 V2
D1/2 V2
D2/2 V2
D0/2 V2
D2/2 V2
D0/2 D1/2 V2
D2/4 D3/3
D1/1 V1
D1/1 V1
D1/1 V1
D0/2
D1/1
D1/3
D1/3 V1
D1/3
D0/3
D1/3
D2/3
D0/3
D1/3
D1/2 V1
D0/3
D2/4
D1/3
D0/3
D1/3
D0/3
D3/3 V1
D0/2 V2
D1/3
D2/2 V2
D2/2 V2
D2/2 V2
D2/2 V2
D1/1
D0/2 V2
D1/2 V2 D2/2
V2
D1/2 V2
D0/3D2/2 V1
D1/2 V2
D2/2 V2
D1/2 V2
D1/1
D2/2 V2
D2/2 V2
D2/2 V2
D1/2 V2
D1/3 V2
D1/3 V2
D1/2 V2
D1/2 V2
D1/3 V2 D2/3
V2
D1/3 V2D1/3
V2
D1/1 V1
DX/X
VX
D1/2 V2 D2/2
V2
D1/2
D2/3 V1
D3/3 V1
D2/2 V2
D1/4
D2/2 D2/2 V2
D0/3 V1 D1/2
V2
D1/2 V2
D0/2 V1
D2/2 V1
D0/2 V1
D1/2 V1
D2/2 V1
D0/2 V1
DX/X
D2/3
D2/2
D2/2 V1
D2/4
D1/1
D0/4
D0/1
D2/4 D2/4
D2/3 D1/2
D1/2 V1
D1/2 V1
D1/2 V1
D0/2 V1 D1/2
V1 D1/2 V1
D1/2 V1
D2/2
D1/1 D1/3
D1/3
OFFICE
1G131
OFFICE
1H113A
TR (NEW)
1H113
NEW TR
OFFICE/STORAGE
1H113B
EXAM
1H114
EXAM
1H115
TR (DECOMMISSIONED)
1F114
TR TO BE DECOMMISSIONED
TECH OFFICE
1F117
EXAM
1G130
EXAM
1G129
EXAM
1G128
CORRIDOR
1C146
EXAM/OFFICE
1G124
EXAM/OFFICE
1G125
EXAM/OFFICE
1G126
EXAM/OFFICE
1G127
OFFICE
1G132
EXAM
1H116
OFFICE
1H124
STAIR
1C162
WAITING
1G137
OFFIC
1H120
OFFICE
1H121
EXAM
1H118
EXAM
1H119
OFFICE
1H122
RECEPTION
1H122A
OFFICE
1H123
EXAM
1H131
BATH
1H132
BREAKROOM
1H128
WORK AREA
1H127
OFFICE
1H136
EXAM
1H139
EXAM
1H138
EXAM ROOM
PMRS
1H143
OFFICE
1H144
OFFICE
PMRS
1H142
HANDICAP TLT
1H149
MALE TLT
1H148
FML TLT
1H147
STORAGE
1H118A
EXAM
1H130
KITCHEN
1H129
WORK STM
1H126
RECEPTION
1H125
WAITING
1H117
EXAM
1H133
TLT
1H145
HAC
1H146
ELEC
EQUIP
TA137A
ELEC
EQUIP
TA137B
FIRE
EQUIP
TA137C
CORRIDOR
1E110
EXAM
1E109
EXAM
1E108
EXAM
1E107
CACI
1F137
RO CLOSET
1F119
SUPPLY
1F138
CASE MGR
1F139
OFFICE
1F121
OFFICE
1F122
OFFICE
1F123
BREAK ROOM
1F124
EXAM
1E106
EXAM
1E105
OFFICE
1F129
CONF RM
1F130
OFFICE
1F126A
OFFICE
1F126
BREAKROOM
1C177
CLINIC PHARM
1F125
CONF ROOM
1F128
OFFICE
1F127
MED PREP
1F111
CORRIDOR
1C126
ELEC EQUIP
1H140A
CK-IN
1H135
WAITING
1H140
OFFICE
1H141
OFFICE
1H151
OFFICE
1H156
OFFICE
1H160
OFFICE
1H159
OFFICE
1H161
MINOR PRO
1C178
STORAGE
1H153
OFFICE/WAITING
1H150
OFFICE
1H154
EXAM
1C182
EXAM
1C183
EXAM
1C184
EXAM
1C185
DRESSING RM
1C186
SOIL
UTIL
1C187
TLT
1C190
VASCULAR
1C191
BREAKROOM
1H155OFFICE
1H152
RECEPT
1C193
ROOM
1C143
EXAM
1C194
EXAM
1C195
BIOPSY RM
1C196
URODYNAMICS
1C197
EXAM 17
1C129
STOR.
1C132
EXAM 16
1C134
EXA 15
1C137
EXAM 14
1C138
HAC
1C142
MEDS
1C144
STORAGE
1C207
EXAM 13
1C140
EXAM 12
1C139
EXAM 11
1C135
EXAM 10
1C133
EXAM 9
1C130
EXAM 8
1C128
EXAM 7
1C127
STORAGE
1F105
WINDOWS
1F104
WAITING
1F101
RESEARCH ROOM
1F102
VAULT
1F113
INPATIENT PHARMACY ACCESS
1C208
ELECT UTIL
1F136
CART STOR
1F135
OFFICE
1E127
CLEAN RM
1E125
DIRTY RM
1E126
NUTRITION
1E121
TLT
1E122
TLT
1E123
TRIAGE
1E119
CLERK
1E118
STAFF BREAKROOM
1E113
ELECT UTIL
1E112 PHONE UTIL
1E113C
FIRE UTIL
1E113B
EXAM ROOM
1E114
OFFICE
1E116
TLT
1E114A
TLT
1E113A
WAITING
1E117
TLT.
1E117A
TLT.
1E116A
HAC
1E120
INFUSION CENTER
1E111
FIRE UTIL
1E123A
EXAM/TRMT
1E128
OFFICE
1E129
CORRIDOR
1E124 CORRIDOR
1E115
STAIR
1C209
TLT
1E104
TLT
1E103 OFFICE
1E102
OFFICE 1E101
1E101
SOILED UTIL
1C122
EXAM 6
1C125
EXAM 5
1C123
TLT
1C210
EXAM
1K133
ECHO
1K132
OFFICE
1K129
BREAKROOM
1K128
WORKROOM
1K125
HAC
1C212
TRASH
1F132
SOILED LINEN
1F131
TLT
1F109
TLT
1F110
MED PREP
1E132
RECEPTION
1F103
OFFICE
1F107 OFFICE
1F108
CLERKS
1E100
CORRIDOR
1C287
Room
1G131GG
Room
1G131HH
Room
1G131II
5 5 10 15 20 25 30
3/32" = 1'-0"
FEETSCALE
PLAN
NORTH
N
FOR OFFICIAL USE ONLY
www.coffman.com
701 Corporate Center Drive, Suite 475
Raleigh, NC 27607 ph 919.314.6686
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL BID DOCUMENTSFacilities Management
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMP
321 4 5 6 7 8 9 10
SHEET NOTES:
SHEET OF
C
KEY PLAN
12/18/2025
A u to d e s k D o c s
/A s h e v ill e E
H R
M V
/6
-2 -7
.0
.E
.A S
H
E H
R M
.r v t
/1 /2
:5
:1
P M
47-TD113
TELECOMMUNICATIONS 1ST FLOOR
DEMOLITION - PART CAwen Solutions Group
215 N. Payne Street, Suite 122
Alexandria, VA 22314
12.19.2025
EHRM INFRASTRUCTURE
UPGRADES BLDG 47
1100 TUNNEL ROAD
ASHEVILLE, NC 28805
637-22-700
GENERAL NOTES:
1. REFER TO 00-T001 FOR GENERAL NOTES AND LEGENDS.
2. ALL EXISTING CABLES AND INFRASTRUCTURE NOT CAT6A RATED TO BE DEMOLISHED.
3. NOT ALL DEVICES ARE SHOWN. CONTRACTOR TO VERIFY ALL DATA OUTLET LOCATIONS IN THE FIELD.
4. THE QUANTITY OF TELECOM DROPS TO BE REMOVED, INSTALLED, AND MAINTAINED IS BASED ON THE INFORMATION KNOWN AT THE TIME OF DESIGN. PRIOR TO CONSTRUCTION, TELECOM DROP LOCATIONS SHALL BE SURVEYED. ANY DISCREPANCIES SHALL
BE PROVIDED TO THE DOR IMMEDIATELY.
5. EXISTING ROUTING FOR TELECOM DROPS TO REMAIN SHALL BE MAINTAINED TO THE FULLEST EXTENT.
6. DEMOLITION DETAILS (IN NO PARTICULAR ORDER):
A. REFER TO ENLARGED PLANS FOR ADDITIONAL REQUIREMENTS.
B. CABLE CAT6 AND BELOW HORIZONTAL CABLE SHALL BE REMOVED FROM EXISTING PATCH PANELS BACK TO FINAL DATA
JACK LOCATIONS. CABLE SHALL BE REMOVED BETWEEN EXISTING SWITCH AND PATCH PANEL.
C. PATCH PANELS CURRENTLY NOT DESIGNED FOR CAT6A CABLE SHALL BE REMOVED.
D. WALL PLATES AND RJ-45 JACKS FOR WALL OUTLET BOXES FOR CAT5E, 6 AND BELOW CABLE SHALL BE REMOVED.
E. DATA RACKS SHALL BE REMOVED.
F. HORIZONTAL AND VERTICAL CABLE MANAGEMENT FOR RACKS SHALL BE REMOVED IF APPLICABLE.
G. WALL MOUNTED FIBER BOXES SHALL BE REMOVED.
H. FIBER CABLE AND ENCLOSURES SHALL BE REMOVED BACK TO SOURCE AFTER ALL NEW FIBER CONNECTIONS IN THIS
BUILDING HAVE BEEN CONNECTED. PRIOR TO DEMOLITION, COORDINATE WITH VA COR TO ENSURE ALL FIBER IS INACTIVE
BEFORE DEMOLITION.
I. EXISTING CABLE TRAY TO REMAIN.
J. COPPER PHONE PUNCH DOWN BLOCKS SHALL REMAIN UNLESS OTHERWISE NOTED.
7. DEMOLISH ALL TELECOMMUNICATIONS CABLE THAT IS NOT TERMINATED AT BOTH ENDS AT A CONNECTOR OR OTHER EQUIPMENT AND NOT IDENTIFIED 'FOR FUTURE USE' WITH A TAG. ENSURE DEMOLITION OF ABANDONED CABLE WILL NOT DISRUPT VA OPERATIONS PRIOR TO REMOVAL. WHERE DISRUPTION OF SERVICE OCCURS DUE TO DEMOLISHED CABLE, NEW CABLE SHALL
BE INSTALLED TO RESTORE THE SYSTEM AT THE CONTRACTOR'S EXPENSE.
8. PRIOR TO DEMOLITION, COORDINATE DISPOSAL WITH VA. ALL VA STANDARDS, EPA STANDARDS AND LOCAL STANDARDS MUST
BE FOLLOWED WHEN DISPOSING OF ASBESTOS EXPOSED ITEMS.
3/32" = 1'-0"
1 TELECOMMUNICATIONS 1ST FLOOR DEMOLITION - PART C
Jinze Chen
D1/2 V1
D0/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D0/2 V1
D2/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D1/2 V1
D2/2 V1 D2/2
V1
D1/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D0/2 V1 D1/2
V1
D0/2 V1
D2/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D2/2 V1
D2/2 V1
D0/2 V1 D0/2
V1
D1/2 V1
D1/2 V1
D2/2 V1
D2/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D2/2 V1
D0/2 V1
D2/2 V1
D0/2 V1
D0/2 V1
D0/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D2/2 V1
D0/2 V1
D0/2 V1
D0/2 V1
D0/2 V1
D1/2 V1
D1/3 V1
D2/2 V1 D2/2
V1D0/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D0/2 V1D1/2
V1
D2/2 V2
D1/2 V1
D0/2 V1
D1/2 V2
D1/2 V2
D1/2 V1
D2/2 V1 D2/2
V1 D0/2 V1
D2/2 V2
D2/2 V2
D0/1 V1
D2/2 V1
D0/1 V1
D2/2 V2
D1/1 V1D1/4
V1
D1/1 D0/3
D2/2
D1/3 V1
D2/3 V1
D2/2
D1/2 V2
/1 47-TD111
/1 47-TD113
/1 47-TD112
D2/2 V2
D1/1
D3/3
D1/2 V2
D0/2
D2/3 V1 D1/3
D3/3 V1 D0/1
D1/3
D2/2 V2
D1/2 V1
D1/3
D1/3
D1/3 D1/3
D1/3 V1
D0/3
D1/3
D1/3
D2/2 V1
D1/2 V1
D2/2 V1
D1/2 V2
D1/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D2/2 V1
D1/2 V1
D0/4D0/2 V2
D1/3 D1/3
D1/2 V1
D2/2 V1
D1/2 V1
D0/3
D0/3
D0/2 V1 D1/2
V1
D1/3 D0/3 D2/3
D1/2
D0/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D1/2 V1
D0/2 V1
D1/2 V1 D2/3
D1/2 V1
D1/1 D1/2 V1
D1/2
D1/2
D1/2
D1/2
D0/1
D1/1
D0/3
D1/2 V1
D1/2 V1
D2/2 V1
D1/4
D1/2 V2
D2/4
D1/4
D0/2 V1
D3/3
D2/2 V1
D2/2 V1
D1/2 V1
D1/2 V1
D1/3
D0/1
D0/2 V1
D1/2 V1
D0/2 V1
D1/2 V1
D0/2 V1
D1/1 V1
D0/2 V1
D1/2 V1
D0/4
D1/2 V1
D0/2 V1
D1/2 V1
D1/2 V1
D0/1
D0/1 D0/1
D1/2 V1
D1/1 V1
D1/1
D0/2 V1
D1/2 V1
D1/1
D1/1 V1
D1/2 V1
D1/2 V2
D3/3
D0/2 D1/1
EXAM
1W131
EXAM
1W130
EXAM
1W129
TR (NEW)
1W133
NEW TR
CONF/TEACH
1W134
TR (DECOMMISSIONED)
1A101D
TR TO BE DECOMMISSIONED
ELEC
1B135 TR (EXISTING)
1B134
EXISTING TR
STAIR
STAFF LOUNGE
1W138
HAC
1W137
TLT
1G134
WORKROOM
1B136
CORRIDOR
1W151
EXAM
1K133 EKG
1K134
ECHO
1K132
OFFICE
1K129
BREAKROOM
1K128
WORKROOM
1K125
ELECT
1K144
HAC
1K123
OFFICE
1K121
OFFICE
1K120
CLEAN UTILITY
1K119
OFFICE
1K143
OFFICE
1K142
STORE ROOM
1K141A
STORE ROOM
1K141B
EXAM
1K118
EXAM
1K117
OFFICE
1K114
OFFICE
1K113
EXAM
1K110
EXAM
1K109
EXAM
1K111
EXAM
1K112
EXAM
1C211
EXAM
1K116
EXAM
1K122
EQ/GAS STORE
1K124
SUB-WAIT
1K106
EXAM
1K131
EXAM
1K130
EXAM
1K127
EXAM
1K126
TRASH
1F132
DEC AFFS
1F133
CLERK
1F134
SOILED LINEN
1F131
STAIR
1C213
MD
1W128
RN
1W127
PHARM D
1W125 PHARM D
1W126
TLT
1W124
PHARM D
1W122
ANEMIA
1W123
MD
1W121
OFFICE
1B138
WORK ROOM
1B140
OFFICE
1B141
OFFICE
1B145
OFFICE
1B146
TOILET
1W101B
OFFICE
1B147OFFICE
1B148
OFFICE
1B149
OFFICE
1B150 OFFICE
1B151
OFFICE
1B152
OFFICE
1B153
OFFICE
1B154
OFFICE
1B131
OFFICE
1B130
OFFICE
1B129
OFFICE
1B128
MED STORE
1B127
EXAM 8
1B121
EXAM 9
1C217
EXAM 10
1C218
EXAM 11
1C219
EXAM 12
1B117
EXAM 13
1B116
EXAM 14
1C220
OFFICE
1K107
EXAM
1K108
OFFICE
1B142
OFFICE
1B143
OFFICE
1B144
EXAM
1W214
EXAM
1B159
EXAM
1B158
EXAM
1B157
EXAM
1B156
EXAM
1B155
CORRIDOR
1B193
CORRIDOR
1B227
TOILET
1C236
ELEC UTIL
TA101C
TELE
1C239
RN CLST
1W143
RN CLST
1W142
STICK (POC)
1W106
PHARMD
1W107
ID
1W144
MD
1W146 RN
1W145MD
1W148
MD
1W149
CLEAN
1W150
DIET
1W139
RN CLST
1W140
ELEC CL
1W147
MD
1W119
RN
1W118
RN
1W120
RN
1W117
MD
1W114
MD
1W115
RN
1W110
RN
1W109
NURSE MGR
1W111
TOILET
1W108
STAIR
1C240
OPTICAL SHOP
1B173
BREAKROOM
1B161
EXAM
1B168
OFFICE
1B169
OFFICE
1B174
HAC
1B162
VENDING
1K141
CLEAN UTL
1B165
SOIL UTIL
1B166
HC TLT
1B167
EXAM 1
1C242
EXAM 15
1C243
EXAM 2
1B110
EXAM
1B111
EXAM
1B111A
EXAM
1C244
EXAM
1B112A
EXAM 3
1C245
MECH CHASE
1C250
CHASE
1C251
EXAM 4
1B122
HC TLT
1B123
EXAM 5
1B124
EXAM 6
1B125
TOILET
1W116
FA CL
1W113
RN
1W121A
LEAD…
This is the start of the file's text. The full file is on GovTribe.