This file is a 100% construction drawing set for the AFD Visitor Center Remodel project located at 5765 US Highway 10 West in Missoula, Montana. The drawings were prepared by Mosaic Architecture, P.C. (Helena, Montana) in conjunction with structural engineering by Morrison-Maierle and MEP engineering by Great West Engineering, all dated September 30, 2024. The project involves remodeling an existing building with key modifications including a new accessible restroom layout, revised reception and exhibit areas, and associated site improvements. The building is classified as mixed occupancy (Business Group B, Assembly A-3, and Storage S-1) with a total actual floor area of 5,600 square feet across one story above grade plane with a basement level. The construction follows Type V-B non-sprinklered design and must comply with the 2021 International Building Code, 2021 International Existing Building Code, 2023 National Electrical Code, and other applicable standards adopted by the USDA Forest Service and State of Montana.
The drawing set includes comprehensive architectural, structural, electrical, mechanical, plumbing, and civil engineering documents organized across multiple sheets covering demolition and new construction plans, floor plans, reflected ceiling plans, roof plans, exterior elevations, building sections, window and door details, interior details, finish schedules, electrical layouts and photometric calculations, mechanical and plumbing systems, and site plans. The project accommodates a maximum occupant load of 38 in the basement and 30 on level 1, with egress design based on standard code requirements for non-sprinklered buildings. Fire-rated walls and opening protection are designated throughout with specific attention to exit signage, egress widths, and interior finish classifications.
View the file
Other files for this federal contract opportunity
Show all 21
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
9/
/2
7:
:4
A
M
09/30/2024
A000
COVER
5765 W Broadway St. Missoula, MT 59808
AFD VISITOR CENTER
REMODEL
C O
N S
T R
U C
T
IO
N S
E T
AFD VISITOR CENTER - REMODEL
5765 US HIGHWAY 10 WEST
MISSOULA, MONTANA 59808 MOSAIC ARCHITECTURE, P.C.
317 N. CRUSE AVE. SUITE 201
HELENA, MT 59601
(406) 449-2013 CONTACT: MATT AUNE, AIA matta@mosaicarch.com
KATIE BRODOWY, AIA katie@mosaicarch.com
ARCHITECT:
STRUCTURAL ENGINEERING:
MEP ENGINEERING:
THESE DRAWINGS WERE PREPARED BY MOSAIC ARCHITECTURE, P.C. FOR CONSTRUCTION OF THE PROJECT DESCRIBED HEREIN. AS SUCH, THE DOCUMENTS ARE THE PROPERTY OF MOSAIC ARCHITECTURE, P.C. & MAY NOT BE REPRODUCED, COPIED OR USED IN ANY WAY WITHOUT PRIOR APPROVAL FROM MOSAIC ARCHITECTURE, P.C.
SHEET INDEX
PROJECT DIRECTORY
VICINITY MAP
PROJECT SITE
ARCHITECTURAL DRAWINGS
A000 COVER
A002 CODE INFORMATION
A003 GENERAL INFORMATION
A004 ASSEMBLY TYPES
A101 SITE PLAN
A101A SITE- LANDMARK SIGN- OPTION ITEM #1
A102 DEMOLITION PLAN
A103 FLOOR PLAN
A104 BASEMENT PLAN
A106 REFLECTED CEILING PLAN
A107 ROOF PLAN
A201 EXTERIOR ELEVATIONS
A302 BUILDING SECTIONS
A501 WINDOW TYPES, WINDOW DETAILS
A502 DOOR TYPES, DOOR DETAILS
A504 INTERIOR DETAILS
A701 FINISH PLAN & SCHEDULE
A801 INTERIOR ELEVATIONS
STRUCTURAL DRAWINGS
ELECTRICAL DRAWINGS
E000 ELECTRICAL SYMBOLS AND ABBREVIATIONS
E001 ELECTRICAL SCHEDULES AND DETAILS
E002 ELECTRICAL SCHEDULES
E003 ELECTRICAL DETAILS
E004 ELECTRICAL DETAILS
E100 ELECTRICAL DEMO BASEMENT
E101 ELECTRICAL DEMO LEVEL 1
E102 ELECTRICAL SITE PLAN
E103 ELECTRICAL POWER BASEMENT
E104 ELECTRICAL POWER LEVEL 1
E201 ELECTRICAL LIGHTING BASEMENT
E202 ELECTRICAL LIGHTING LEVEL 1
E203 PHOTOMETRIC CALC
MECHANICAL DRAWINGS
M000 MECHANICAL LEGEND & NOTES
M001 MECHANICAL SCHEDULES
M002 MECHANICAL SCHEDULES
M003 MECHANICAL DETAILS
M100 MECHANICAL BASEMENT DEMO PLAN
M101 MECHANICAL LEVEL 1 DEMO PLAN
M102 MECHANICAL BASEMENT PLAN
M103 MECHANICAL LEVEL 1 FLOOR PLAN
PLUMBING DRAWINGS
P000 PLUMBING LEGEND & NOTES
P001 PLUMBING SCHEDULES
P002 PLUMBING SCHEDULES
P003 PLUMBING DETAILS
P100 PLUMBING BASEMENT DEMO PLAN
P101 PLUMBING LEVEL 1 DEMO PLAN
P102 PLUMBING BASEMENT PLAN
P103 PLUMBING LEVEL 1 PLAN
MORRISON-MAIERLE
1055 MOUNT AVE.
MISSOULA, MT 59801
(406) 542-8880 CONTACT: TANNER EVENSON, PE tevenson@m-m.net
MORRISON-MAIERLE
1055 MOUNT AVE.
MISSOULA, MT 59801
(406) 542-8880 CONTACT: GARTH STEVENS, PE gstevens@m-m.net
LUKASH HOFF-PRUSS, lhoffpruss@m-m.net
CIVIL ENGINEERING:
GREAT WEST ENGINEERING
2501 BELT VIEW DRIVE
HELENA, MT 59601
(406) 449-8627
CIVIL DRAWINGS
C100 EXISTING SITE AND DEMOLITION PLAN
C101 OVERALL SITE PLAN
C102 DETAILS
CONTACT: JOSH SOMMER, jsommer@greatwesteng.com
# DATE REVISION
UP
DN
DN
DN
DN
F
304.1 BUSINESS GROUP B
61' TO DOOR
GROSS
1276 SF
S-1
GROSS
324 SF
B
FE
NONRATED WALL: WITH NO OPENING PROTECTION REQUIRED AT DOORS,
WINDOWS, DUCTS, PENETRATIONS, AND JOINTS UON. SEE WALL TYPES.
EXIT SIGN W/ INTEGRATED DIRECTIONAL ARROW WHERE OCCURS AT ALL
EXITS, EVERY 100' IN CORRIDORS, AND IN SPACES WHERE 2 MEANS OF
EGRESS ARE REQUIRED PER S §1006. SEE ELECTRICAL DRAWINGS. (W/
POCHE IN QUADRANT INDICATING "EXIT" TEXT SIDE OF SIGN.) SIGNS
SHOWN IN CORRIDORS ARE CEILING HUNG. SIGNS SHOWN ON WALL ARE
WALL HUNG.
1-HOUR FIRE WALL, FIRE BARRIER, FIRE PARTITION, OR SMOKE BARRIER
WALL: OR COMBINATION OF (WHERE OCCURS) CONFORMING TO THE MOST
STRINGENT REQUIREMENTS OF EACH. SEE CODE ANALYSIS PLANS FOR
SPECIFIC NAMES OF IBC WALL DESIGNATIONS. ALL WITH FIRE-RESISTIVE
OPENING PROTECTION AT DOORS, WINDOWS, DUCTS (WITH EXCEPTIONS),
PENETRATIONS, AND PROTECTION AT JOINTS. SEE WALL TYPES, DOOR AND
WINDOW SCHEDULES, MECHANICAL DRAWINGS, PENETRATION DETAILS, AND
JOINT DETAILS WHERE APPLICABLE.
2-HOUR FIRE WALL OR FIRE BARRIER: OR COMBINATION OF (WHERE
OCCURS) CONFORMING TO THE MOST STRINGENT REQUIREMENTS OF EACH.
SEE CODE ANALYSIS PLANS FOR SPECIFIC NAMES OF IBC WALL
DESIGNATIONS. ALL WITH FIRE-RESISTIVE OPENING PROTECTION AT
DOORS, WINDOWS, DUCTS (WITH EXCEPTIONS), PENETRATIONS, AND
PROTECTION AT JOINTS. SEE WALL TYPES, DOOR AND WINDOW
SCHEDULES, MECHANICAL DRAWINGS, PENETRATION DETAILS, AND JOINT
DETAILS WHERE APPLICABLE.
PORTABLE CLASS ABC FIRE EXTINGUISHER IN ADA-COMPLIANT SEMI
RECESSED CABINET
FE
Wmin MINIMUM EGRESS WIDTH (INCHES) BASED ON ACCUMULATIVE NUMBER OF
OCCUPANTS SERVED AT INDICATED EGRESS COMPONENT, PER SECTION
1005.3: .3 INCHES/OCC FOR STAIRWAYS(NONSPRINKLERED BUILDINGS); .2
INCHES/OCC FOR OTHER EGRESS COMPONENTS (NONSPRINKLERED BLDGS).
MOER:2 MEANS OF EGRESS REQUIRED (QUANTITY). ONLY DESIGNATED WHERE
(2) MEANS OF EGRESS ARE REQUIRED, PER §1006.2.1.
IU INCIDENTAL USE W/ REQUIRED SEPARATION PER TABLE 509. SHALL NOT
OCCUPY >10% OF FLOOR AREA OF STORY IN WHICH LOCATED, AND IS
CALCULATED AS PART OF OCCUPANCY IN WHICH IT IS LOCATED.
ACCESSORY OCCUPANCY AREA: W/ NO SEPARATION REQUIRED AND
CALCULATED AS PART OF MAIN OCCUPANCY IF TOTAL ACCESSORY
OCCUPANCIES WITHIN A STORY OCCUPY LESS THAN 10% OF AREA OF THAT
STORY, PER SECTION 508.2.
CODE PLAN LEGEND
OCCUPANCY GROUP B AREA
OCCUPANCY GROUP S-1 AREA
EXIT ACCESS TRAVEL DISTANCE - MAXIMUM 200' FOR 'B' OCCUPANCY W/OUT
SPRINKLER SYSTEM, PER TABLE 1017.2. MAXIMUM DISTANCE FOR EACH
STORY SHOWN.
COMMON PATH OF EGRESS TRAVEL - MAXIMUM 75' FOR 'B' OCCUPANCY
W/OUT SPRINKLER SYSTEM, OCC LOAD >30, PER TABLE 1006.21.
ROOM AREA
OCCUPANT
LOAD
MAX. FLOOR
AREA PER
OCCUPANT
FROM TABLE
1004.5
SF
ROOM NAME
OCCUPANT LOADS FOR FUNCTIONS DESIGNATED NET
FLOOR AREA IN TABLE 1004.5 ARE IDENTIFIED FOR
ACTUAL OCCUPIED AREAS.
OCCUPANT LOADS FOR FUNCTIONS DESIGNATED GROSS
FLOOR AREA ARE IDENTIFIED FOR ENTIRE AREA OF THE
FUNCTION W/ DEDUCTIONS ONLY FOR AREA OF
EXTERIOR WALLS, VENT SHAFTS AND INTERIOR COURTS.
AO
OCCUPANCY GROUP A AREA
REQUIRED EXIT AND EXIT EGRESS DIRECTION WITH ACCUMULATIVE
NUMBER OF OCCUPANTS SERVED. (DESIGNATED WHERE (2) MEANS OF
EGRESS ARE REQUIRED PER TABLE §1006.2.1)
THIS PROJECT SHALL COMPLY WITH THE LATEST EDITION OF CODES ADOPTED BY THE USDA
FOREST SERVICE STATE OF MONTANA:
2021 International Building Code (IBC) 2021 International Existing Building Code (IEBC) 2021 International Mechanical Code (IMC) 2021 International Fuel Gas Code (IFGC) 2021 International Plumbing Code (IPC) 2023 National Electrical Code (NEC) 2021 International Fire Code (IFC) 2021 International Energy Conservation Code (IECC)
APPLICABLE BUILDING CODES
OCCUPANCY GROUPS:
(CHAPTER 3)
• B - BUSINESS
• A - ASSEMBLY
• S - STORAGE
NONSEPARATED OCCUPANCIES:
(SEC. 508.3.2)
CONSTRUCTION TYPE:
(TABLE 601)
TYPE V-B, NON-SPRINKLERED
ALLOWABLE FLOOR AREA (At):
(TABLE 506.2)
B:
A-3:
S-1:
9,000 SF
6,000 SF
9,000 SF
FRONTAGE INCREASE BLDG 1 (If):
(SEC. 506.3.3)
If = [F / P - 0.25] W / 30 If = [1 - 0.25] 30 / 30 If = .75
ALLOWABLE FLOOR AREA:
1 STORY BLDG: (Aa)
(SEC. 506.2.1)
A-3:
ALLOWABLE NO. OF STORIES ABOVE
GRADE PLANE / HEIGHT:
(TABLE 504.4/504.3)
A-3:
B:
S-1:
1 STORY / 40 FT*
2 STORIES / 40 FT
1 STORY / 40 FT*
*MOST RESTRICTIVE REQUIREMENTS GOVERN
OCCUPANT LOAD BY FLOOR: LEVEL 1 30
BASEMENT 8
SEE CODE ANALYSIS PLANS THIS SHEET.
SUMMARY CODE REVIEW
PROJECT DESCRIPTION: REMODEL OF EXISTING BUILDING, INCLUDING NEW ACCESSIBLE
RESTROOM LAYOUT,REVISED RECEPTION AND EXHIBIT AREA
ACTUAL NO. OF STORIES / HEIGHT: 1 STORY ABOVE GRADE PLANE / 21 FT; OK
OCCUPANT LOADS FOR EGRESS DESIGN:
(SEC. 1004 + TABLE 1004.5)
SEE CODE ANALYSIS PLAN. OCCUPANT LOADS BASED ON MAX. FLOOR
AREA IN SQ FT PER OCCUPANT FROM TABLE 1004.5:
EGRESS WIDTH PER OCCUPANT SERVED:
(SEC. 1005.1)
STAIRWAYS:
OTHER EGRESS
COMPONENTS:
0.3 INCHES / OCCUPANT (NONSPRINKLERED)
BASEMENT OCC 12 x .3 = 3.6"
0.2 INCHES / OCCUPANT (NONSPRINKLERED)
BUILDING OCC 105 x .2 = 21"
INTERIOR FINISH REQUIREMENTS:
(TABLE 803.13)
INTERIOR EXIT STAIRWAYS, EXIT RAMPS & EXIT PASSAGEWAYS: CLASS A.
CORRIDORS & ENCLOSURE FOR EXIT ACCESS STAIRWAYS & EXIT ACCESS
RAMPS: CLASS B. ROOMS AND ENCLOSED SPACES: CLASS C
THIS MIXED OCCUPANCY BUILDING INCORPORATES NONSEPARATED
OCCUPANCIES. NO OCCUPANCY SEPARATIONS ARE PROVIDED, AND
THE ALLOWABLE AREA AND HEIGHT OF THE BUILDING IS BASED ON
THE REQUIREMENTS OF THE MOST RESTRICTIVE OCCUPANCY.
Aa = At + [NS x If] Aa = 6,000 + [6,000 x .5] Aa = 9,000 SF
ACTUAL FLOOR AREA: 5,600 SF< 9,000 SF ALLOWABLE; OKEXSTING & NEW:
44" AT STAIRWAYS (36" WHERE OCC LOAD < 50) [IBC §1011.2]; PROVIDED
32" CLEAR AT DOORS [§1008.1.1], PROVIDED
44" AT CORRIDORS, AISLES & EXIT PASSAGEWAYS (36" for occupant load
<50) [§ 1020.2; 1018.3 - 1018.5; 1024.2 RESPECTIVELY], PROVIDED.
EGRESS WIDTH MINIMUMS BY
COMPONENT (USE WHERE EXCEED
MINIMUMS BY OCCUPANT LOAD):
CORRIDOR FIRE RESISTANCE RATING:
(TABLE 1020.1)
B OCCUPANCY, OCC LOAD <30 @ CORRIDOR:
NOT REQUIRED (NONSPRINKLERED)
OPENING PROTECTIVES:
(TABLE 716.1(2))
EXIT ACCESS TRAVEL:
(TABLE 1017.2)
OCC. LOAD TOTAL SF OCCUPANTS
EXHIBIT GALLERY AND MUSEUM 30 NET 692 SF 24 OCC.
BUSINESS: 150 GROSS 859 SF 6 OCC.
30 total occcupants
LEVEL 1
OCC. LOAD TOTAL SF OCCUPANTS
BUSINESS: 150 GROSS 324 SF 3 OCC.
STORAGE: 300 GROSS 1276 SF 5 OCC.
8 total occcupants
BASEMENT LEVEL
A, B, S-1 - 200' NONSPRINKLERED
REQUIRED SPECIAL INSPECTIONS:
IN ADDITION TO REGULAR INSPECTIONS, THE FOLLOWING ITEMS WILL ALSO REQUIRE SPECIAL INSPECTIONS AND TESTING IN ACCORDANCE WITH SECTIONS 1704 AND 1705 OF THE 2018 INTERNATIONAL BUILDING CODE.
SEE STRUCTURAL FOR SPECIFIC REQUIREMENTS. COPIES OF 3RD PARTY REPORTS TO BE SENT TO FOREST
SERVICE & COPIES KEPT ON-SITE FOR INSPECTOR REVIEW.
a) SPECIAL INSPECTIONS:
- INSPECTION OF FABRICATORS (1704.2.5)
- STEEL CONSTRUCTION (1705.2)
- CONCRETE CONSTRUCTION (1705.3)
- MASONRY CONSTRUCTION (1705.4)
- WOOD CONSTRUCTION (1705.5)
- SOILS (1705.6)
- SPECIAL CASES (1705.1.1)
EPOXY SET ANCHORS
POWDER-ACTUATED FASTENERS
CONCRETE EXPANSION ANCHORS
b) SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE (1705.12):
- STRUCTURAL STEEL (1705.12.1)
- STRUCTURAL WOOD (1705.12.2)
- COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION (1705.12.3)
IECC COMPLIANCE FOR COMMERCIAL PROJECTS
CLIMATE ZONE: 6
INSULATION REQUIREMENTS - IECC 2021 TABLE C402.1.3/C402.4 AND MT AMENDMENTS
ROOFS R-30 CONTIUOUS ABOVE DECK, R-49 AT ATTICS
METAL FRAMED WALLS, ABOVE GRADE R-13 CAVITY + R-12.5 CONTINUOUS
WOOD FRAMED WALLS, ABOVE GRADE R-13 CAVITY + R-7.5 CONTINUOUS OR R-20 + R-3.8 CONTINUOUS
MASS WALLS, ABOVE GRADE: R 13.3 CONTINUOUS
BELOW GRADE WALLS: R-10 CONTINUOUS
FLOORS - JOIST/FRAMING: R-38
UN-HEATED SLAB: R-20 VERTICAL FOR 24" BELOW (FULL HEIGHT OF THICKENED SLAB EDGE)
HEATED SLAB: R-15 FOR 36" BELOW + R-5 FULL SLAB
OPAQUE SWINGING DOORS: U-0.37
OPERABLE FENESTRATION U-FACTOR: 0.42, MAXIMUM
FIXED FENESTRATION U-FACTOR: 0.34, MAXIMUM
ENTRANCE DOOR: 0.63, MAXIMUM
SHGC 0.40 WITH ADJUSTMENT FOR PROJECTION FACTOR >.2
INSULATION TO BE PROVIDED - REQUIREMENTS IN OTHER AREAS OF DRAWINGS OR SPECIFICATIONS TAKE
PRECEDENCE OVER THE FOLLOWING REQUIREMENTS:
ROOFS R-30 CONTIUOUS RIGID INSULATION
WOOD FRAMED WALLS: R-21 CAVITY + R3.8 CONTINUOUS
UNHEATED SLAB: R-10 VERTICAL FOR 24" BELOW (FULL HEIGHT OF THICKENED SLAB EDGE)
OPAQUE SWINGING DOORS: U-0.37
ROLL UP OR SLIDING DOORS R-4.75
FENESTRATION U-FACTOR (FIXED): 0.34 MAXIMUM
FENESTRATION U-FACTOR (OPERABLE): 0.42, MAXIMUM
ENTRANCE DOOR: 0.63, MAXIMUM
SHGC 0.40 WITH PROJECTION FACTOR <.2
PLUMBING FIXTURE COUNTS
(PER ADMINISTRATIVE RULES OF MONTANA 24.301.351)
FIXTURE TYPE
WC, MALE:
WC, FEMALE:
WC, MALE:
WC, FEMALE:
FIXTURES
REQUIRED
1:25 1:25
1:125 1:65
BU
SI
N
ES
S
NO.
OCC.
TOTAL
REQUIRED
FIXTURES
PROVIDED
1 WC + 2 UR*
3 WC
*PER ADMINISTRATIVE RULES OF MONTANA 24.301.351FOOTNOTE M, WHERE URINALS ARE PROVIDED, NOT WITHSTANDING THE REQUIRED URINAL IN FOOTNOTE G ABOVE, ONE WATER CLOSET LESS THAN THE NUMBER SPECIFIED MAY BE PROVIDED FOR EACH URINAL INSTALLED, EXCEPT THE NUMBER OF WATER CLOSETS IN SUCH CASES SHALL NOT BE REDUCED TO LESS THAN ONE-HALF OF THE MINIMUM SPECIFIED.
LAVS, MALE:
LAVS, FEMALE:
DF:
1 PER 2 WC
1 PER 2 WC
1 PER 100
OCCUPANT LOAD - BUSINESS = 7
ASSEMBLY = 23
STORAGE = 4
AS
SE
M
BL
Y
Occupancy Classification: A- Assembly Construction type : VB UL Square Footage
OCC. LOAD TOTAL SF OCCUPANTS
ASSEMBLY : 30 NET 692 SF 23 OCC.
BUSINESS: 150 GROSS 1,182 SF 8 OCC.
STORAGE: 300 GROSS 1,276 SF 5 OCC.
OCC LOAD W/C TOTAL WC
ASSEMBLY: 23 (12M, 12F) 1PER 65 12/65 = .18
BUSINESS: 8 (4M, 4F) 1PER 25 4/25 = .16
STORAGE: 5 (3M, 3F) 1PER 100 3/100 = .03
TOTAL WC REQ PER GENDER = .37 OR 1 PER GENDER BUILDING WIDE
57'
GROSS
859 SF
B
NET
692 SF
A
4'
4"
56' OVERALL
27' BETWEEN EXITS
FE
FE
STAIR TO LOWER LEVEL
CONFERENCE ROOM
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
9/
/2
7:
:4
A
M
09/30/2024
A002
CODE INFORMATION
5765 W Broadway St. Missoula, MT 59808
AFD VISITOR CENTER
REMODEL
C O
N S
T R
U C
T
IO
N S
E T1/8" = 1'-0"
BASEMENT CODE PLAN
1/8" = 1'-0"
LEVEL 1 CODE PLAN
11/8" = 1'-0"
LEVEL 1 EXISTING BUILDING
1/8" = 1'-0"
BASEMENT EXISTING BUILDING
@ at A.B. anchor bolt A/C air conditioning ACC PNL access panel ACOUST acoustical ACT acoustical ceiling tile AD area drain ADJ adjacent AFF above finished floor AIB air infiltration barrier ALT alternate ALUM aluminum ANOD anodized APPROX approximate ARCH architect AUTO automatic BBD bulletin board BD board BITUM bituminuous BL building line BLDG building BLK block BLKG blocking BM beam/bench mark BO by owner B.O. bottom of BOT bottom BRG bearing BSBD baseboard BTWN between B.O.W. bottom of wall BU built up CAB cabinet CAP capacity CB catch basin CL centerline C.C. center to center CDX exterior grade plywood CG corner guard CH channel CI cast iron/cubic inches CJ control joint CLG ceiling C.L.L. contract limit line CL center line
ABBREVIATIONS:
GA gauge GB grab bar GALV galvanized G.C. general contractor GEN general GFRG glass fiber reinforced gypsum GI galvanized iron GL glass GLU LAM or G.L.B. glue laminated beam GRD grade/grid GWB gypsum wall board GYP gypsum HB hose bib HC hollow core/handicapped HD BD Hard board HDR header HOR horizontal HR hour HT height HTG heating HVAC heating, ventilation, air conditioning HW hot water
PART.BD.particle board PART’N partition PC precast concrete PFM prefinished metal PL plate P.LAM plastic laminate PLWD plywood PNL panel PR pair PSL parallel strand lumber PT point PTD paper towel dispenser
T tread/thermostat TB towel bar TEL telephone TEMP temperature T&G tongue and groove THK thick THRU through TJI Truss Joist Incorporated
CLR clear CMU concrete masonry unit CO clean out COL column CONC concrete COND condition CONF conference CONN connection CONST construction CTRD centered CONT continuous CONTR contractor CORR corridor CPT carpet CT ceramic tile CUH cabinet unit heater CW curtain wall system CY cubic yard DBL double DEPT department DF drinking fountain DIA diameter DIAG diagonal DIM dimension DISP dispenser DN down DR door DWR drawer DS downspout DTL detail DWG drawing E east EA each EIFS exterior insulation finish system E.J. expansion joint EL/ELEV elevation - height/elevator ELEC electrical ENCL enclosure EO electrical outlet EP electrical panel EQ equal EQUIP equipment EWA/EW exterior wall assembly EWC electrical water cooler EWH electrical water heater (E)/EXISTexisting EXH exhaust EXP expansion EXT exterior
IN inch INCL included INFO information INSUL insulation INT interior IWA/IW interior wall assembly
T.O. top of T.O.B. top of beam T.O.C. top of concrete T.O.P. top of plate T.O. FTG top of footing T.O.S. top of steel T.O.SL. top of slab T.O.W. top of wall TPD toilet paper dispenser TR tread TS tubular steel TV television TYP typical UG underground UNO unless noted otherwise UR urinal VAC vacuum outlet VAR varies VB vapor barrier VCT vinyl composition tile VERT vertical VEST vestibule VFY verify VT vinyl tile VWC vinyl wall covering W west/women/width W/ with W/O without WC water closet WD wood W/D washer/dryer WH water heater WNDW window WP waterproof WR water resistant WRB weather resistive barrier WT weight WWF welded wire fabric WWM welded wire mesh X by YD yard
REINF reinforcing REQD required RES resilient RM room RO rough opening RV roof vent R&S rod and shelf S south SACT suspended acoustical ceiling tile SC solid core SCD seat cover dispenser SCHED schedule SD soap dispenser SECT section SF square feet SGL single SHT sheet SHTG sheathing SHWR shower SIM. similar S.I.P. structural insulated panel SLNT sealant SOG slab on grade SPEC specifications S.S. stainless steel SS service sink SSM solid surface material STD standard STF storefront STL steel STOR storage STRUCT structural SUBFLR subfloor SUSP suspended SV sheet vinyl SY square yard
M men's MAT material MAX maximum MECH mechanical MDF medium density fiber board MEMB membrane MEZZ mezzanine MFR manufacturer MH manhole MIN minimum MIR mirror MISC miscellaneous MO masonry opening MTL metal MULL mullion N north NA not applicable NIC not in contract NO number NTS not to scale OFCI owner furnished/contractor installed OC on center OD outside diameter OH overhead/opposite hand OPNG opening OPP opposite
FLR/FL floor FLUOR fluorescent FND feminine napkin dispenser/disposal FOC face of concrete FOF face of finish FOS face of stud FOW face of wall FT foot or feet FTG footing
QTY quantity R/RAD radius R riser RA roof/ceiling assembly RB rubber base RD roof drain RE regarding REF reference/refrigerator
JAN janitor JST joist JT joint LAV lavatory LF lineal foot LTG lighting
FA fire alarm/floor-ceiling assembly FAH fire alarm horn FAS fire alarm station FD floor drain FDN/FND foundation FE fire extinguisher FEC fire extinguisher cabinet FF finished floor FFHB frost free hose bib FG finish grade FH fire hydrant FIN. FLR top of floor sheathing FIN finish FIXT fixture F.O. face of
PTD/R paper towel dispenser/receptacle PVMT pavement PVC polyvinylchloride
1. CONTRACT DOCUMENTS INCLUDE THE ARCHITECT'S DRAWINGS, SPECIFICATIONS, GENERAL
CONDITIONS, AGREEMENT (BUILDING CONTRACT) AND ALL ADDENDA. THEY ARE TO INCLUDE ALL
LABOR, EQUIPMENT, AND MATERIALS NECESSARY FOR THE PROPER EXECUTION OF THE WORK
EXCEPT AS MAY BE SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS OR FOR WHICH
SEPARATE PRICES MAY BE ASKED IN THE BID PROPOSAL.
2. REGULATIONS, TAXES AND PERMITS: THE WHOLE OF THE WORK IS TO BE EXECUTED IN STRICT
ACCORDANCE WITH THE REGULATIONS AND CODES OF THE GOVERNMENTAL AGENCIES WHOSE
JURISDICTION IS APPLICABLE.
GENERAL CONDITIONS:
1. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS & CONDITIONS.
EXISTING DIMENSIONS SHOWN ARE APPROXIMATE AND MUST BE FIELD VERIFIED.
2. REFER TO SPECIFICATIONS FOR DETAILED DESCRIPTIONS & REQUIREMENTS OF
CONSTRUCTION.
3. GENERAL CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES, PROVIDE ON-SITE
SUPERVISION & BE RESPONSIBLE FOR COMPLIANCE WITH ALL SAFETY PRECAUTIONS, CODES
AND REGULATIONS.
4. PROTECT EXISTING UTILITIES, SITE IMPROVEMENTS & PLANTING TO REMAIN.
5. PATCH ANY SURFACES DAMAGED DURING CONSTRUCTION. SURFACES ARE TO BE PATCHED
FLUSH WITH EXISTING. MATCH EXISTING ADJACENT FINISH OR APPLY NEW FINISH AS
SCHEDULED.
6. PROVIDE SOLID BACKING FOR ALL WALL-MOUNTED ITEMS.
7. IN GENERAL, REPETITIVE DETAILS DRAWN ARE SHOWN IN FULL ONLY ONCE. REPETITIONS MAY
NOT BE COMPLETE IN EVERY DETAIL AS SHOWN IN THE ORIGINAL DETAIL.
8. DIMENSIONS ARE SHOWN ON THE DRAWINGS. DO NOT SCALE THE DRAWINGS.
9. ALL HEIGHTS ARE DIMENSIONED FROM THE TOP OF SUBFLOOR UNLESS NOTED OTHERWISE.
10. WHERE COLUMNS & STUD WALLS ALIGN, GYPSUM BOARD TO BE CONTINUOUS OVER COLUMNS
OR BOXED AROUND COLUMN IF COLUMN PROJECTS BEYOND WALL.
11. BRING TO THE ATTENTION OF THE ARCHITECT ANY CONDITION OR AREA OF FINISH THAT IS IN
QUESTION OR NOT NOTED.
12. SEAL ALL PENETRATIONS OF WALLS, FLOORS AND CEILINGS WITH A FIRE RATING EQUIVALENT
TO THE CONSTRUCTION PENETRATED AND PER DETAILS & SPECIFICATIONS.
13. DUST BARRIERS MUST BE INSTALLED WHEREVER NEW WORK IS ADJACENT TO OCCUPIED
AREAS. BARRIERS MUST BE SEALED TO INSURE NO DUST TRANSMISSION TO OCCUPIED SPACES.
14. COORDINATE LAYOUT, CLEARANCES, PENETRATIONS, BACKING & FASTENERS WITH WORK TO
FOLLOW.
15. HEATING, PLUMBING AND ELECTRICAL PLANS WHERE SHOWN DIAGRAMMATICALLY ARE
INTENDED TO INDICATE CAPACITY, SIZE, LOCATION & GENERAL ARRANGEMENTS. ALL
NECESSARY FEATURES OF RELATED CONSTRUCTION WILL BE REQUIRED AS IF SHOWN IN
DETAIL.
16. WHERE MECHANICAL & ELECTRICAL EQUIPMENT LOCATIONS CONFLICT ELECTRICAL, LIGHT
FIXTURE LOCATIONS SHALL TAKE PRECEDENCE.
17. PROVIDE SUFFICIENT STUD DEPTH TO CONCEAL MECHANICAL & ELECTICAL WORK IN WALLS.
18. PROVIDE ALL NEW MATERIALS (U.N.O.) AND QUALIFIED CRAFT PERSONS TO COMPLETE THE
WORK.
19. CONSTRUCTION DOCUMENTS SHOW THE DESIGN INTENT OF THE PROJECT AND MAY NOT SHOW
MINOR DETAILS OF PROPOSED INSTALLATIONS. THE INCLUSION OF THESE MINOR DETAILS IS
IMPLIED TO PROVIDE A COMPLETE PROJECT AND ARE TO BE INCLUDED AS A PART OF A BID.
20. REFER TO MECHANICAL & ELECTRICAL DRAWINGS FOR COORDINATION OF WORK.
21. CONTRACTOR SHALL PROMPTLY REMOVE ALL WASTE MATERIALS AND LEAVE PREMISES AND
SITE CLEAN.
22. THE CONTRACTOR SHALL PROVIDE ALL CEILING AND/OR WALL ACCESS PANELS/DOORS AS
REQUIRED BY THE AIR CONDITIONING, PLUMBING & ELECTRICAL SYSTEMS, PROVIDE APPROVED ASSEMBLIES W/ SELF-CLOSING DEVICES IN RATED CONSTRUCTION. (PAINT TO MATCH ADJACENT
WALL COLOR)
23. ELECTRICAL OUTLETS AND LIGHTING ARE ONLY SHOWN ON ARCHITECTURAL "A" SHEETS WHERE
PLACEMENT OF SUCH IS CRITICAL TO PARTICULAR AESTHSTICS. SEE ELECTRICAL DRAWINGS
FOR ALL ELECTRICAL AND DATA FEATURES.
DRAWING SET NOTE: THESE DRAWINGS ARE TO BE UTILIZED AS A COMPLETE SET FOR BIDDING &
CONSTRUCTION. INDIVIDUAL SECTIONS OF DRAWINGS SHOULD NOT BE SEPARATED FROM THE
ENTIRE SET. IMPORTANT NOTES FOR ONE AREA OF WORK MAY BE INCLUDED IN OTHER AREAS IN
THE DRAWINGS. ALL CONTRACTORS & SUPPLIERS MUST REVIEW ENTIRE DRAWING SET &
SPECIFICATIONS.
GENERAL NOTES:
GENERAL WALL NOTES
1. WALL TYPE CONSTRUCTION IS CONTINUOUS FROM SLAB TO ROOF FRAMING ABOVE UNLESS
INDICATED OTHERWISE.
2. IF A WALL TYPE IS NOT INDICATED, PROVIDE WALL TYPE OF MOST SIMILAR CONDITION - VERIFY
WITH CO.
3. IN CASES OF CONFLICT BETWEEN SECTIONS AND WALL TYPES, CLARIFY WITH ARCHITECT PRIOR
TO BIDDING WHEN TIME ALLOWS, OTHERWISE ASSUME THE MOST EXPENSIVE CONDITION FOR
BIDDING PURPOSES.
4. STRUCTURAL NOTES, SPECIFICATIONS, STUD GAUGE NOTATIONS ETC. TAKE PRECEDENCE OVER
ARCHITECTURAL WALL TYPES.
5. FOR LIGHT GAUGE (NON-STRUCTURAL) METAL FRAMING, PROVIDE MIN. 22 GAUGE STUDS UNLESS
THE CONTRACTOR CAN PROVIDE MANUFACTURER'S DATA SUPPORTING LIGHTER GAUGE STUDS
BASED ON HEIGHT AND FINISH MATERIALS.
6. ALL VOIDS IN EXTERIOR WALLS - INCLUDING IN NON-VISIBLE LOCATIONS - TO BE FILLED TIGHT WITH INSULATION. SMALL CRACKS & VOIDS TO BE CAULKED OR SPRAY-FOAMED FOR TIGHT SEAL.
7. ALL EXTERIOR WALLS TO RECEIVE VAPOR BARRIER UNDER INTERIOR FINISH. ALL SEAMS OF VAPOR BARRIER MUST BE TAPED/SEALED TIGHT AND ALL JOINTS MUST BE TAPED/ SEALED TIGHT
WITH MATERIALS AND METHODS APPROVED BY VAPOR BARRIER MFR.
8. TYPE "X" GYPSUM WALL BOARD SPECIFIED THROUGHOUT. PROVIDE WATER-RESISTANT TYPE "X"
GYPSUM BOARD ON ENTIRE WALL WHERE PLUMBING FIXTURES OCCUR. PROVIDE TILE BACKER
BOARD TYPE "X" ON ALL WALLS WITH TILE.
9. WALLS INDICATED WITH ACOUSTICAL INSULATION TO MEET AN STC RATING OF 48 OR MORE, UNLESS OTHERWISE INDICATED.
10. PROVIDE SOUND ATTENUATION INSULATION ON TOP OF ACT WHERE WALLS TERMINATE AT
CEILING OR 6" ABOVE CEILING. EXTEND 5 FEET TO BOTH SIDES OF WALL. HOLD INSULATION 7"
AWAY FROM LIGHT FIXTURES.
11. PROVIDE BACK ROD & CAULKING JOINT AT ABUTMENT OF ALL DISSIMILAR MATERIALS.
12. PROVIDE STEEL "J" EDGE METAL AND 1/4" CAULK JOINT AT PERIMETER OF ALL GYPSUM BOARD
WALLS WHERE ABUTTING DIFFERENT MATERIALS.
13. PROVIDE CORNER BEADS AT ALL EXTERNAL GYPSUM BOARD CORNERS.
14. PENETRATIONS OF FIRE-RESISTIVE WALLS, HORIZONTAL ASSEMBLIES SHALL BE PROTECTED AS
REQUIRED IN IBC SECTION 714.
15. PROVIDE FIRE, SMOKE AND CEILING RADIATION DAMPERS AT DUCT PENETRATIONS AND AIR
TRANSFER OPENINGS IN FIRE RATED ASSEMBLIES PER IBC SECTION 717.
SCALE
BUILDING SECTIONS
WALL SECTIONS
EXTERIOR ELEVATION
DETAIL CALLOUT
INTERIOR ELEVATION
DOOR NUMBER
WINDOW TYPE
ROOM NAME, NUMBER, AND
AREA
GRID LINES:
LETTERS LEFT TO RIGHT
NUMBERS TOP TO BOTTOM
WALL TYPE
ELEVATION TAG, FLOOR = 100' - 0"
REFERENCE SYMBOLS:
DRAWING TITLE
STOREFRONT/CURTAINWALL
CALLOUT
TEXT INDICATES STOREFRONT
SYSTEM:
iSF = INTERIOR STOREFRONT
SF = EXTERIOR STOREFRONT
CW = CURTAINWALL
FIRE EXTINGUISHER, SEE CODE
PLANS
SHEET
NUMBER
DRAWING
NUMBER
SHEET
NUMBER
DRAWING
NUMBER
SHEET NUMBER
DRAWING
NUMBER
SHEET NUMBER
DRAWING
NUMBER
SHEET NUMBER
DRAWING NUMBER
FEWALL-HUNG, NO
CABINET
ROOF TYPE
-SEE ELEVATIONS FOR HEIGHTS
"SIM" INDICATES SIMILAR
CONDITION; SEE NOTES
FLOOR TYPE
A7-14
A3-8
A5-2
VIEW NAME
1/8" = 1'-0"
A
Room name
A
101A
A1-1
A1-1
FA1
Name
Elevation
RA1
SIM
cw1 i1
MEN
5/8" MIN. - 2" MAX. HEIGHT
1/32" RAISED CHARACTERS
UPPERCASE, SANS SERIF
PICTOGRAMS
6"
BRAILLE CHARACTERS
6"
3"
WOMEN
6"
6"
3"
PICTOGRAMS
BRAILLE CHARACTERS
A
B
MEN'S HC
RESTROOM
WOMEN'S HC
RESTROOM
5/8" MIN. - 2" MAX. HEIGHT
1/32" RAISED CHARACTERS
UPPERCASE, SANS SERIF
PROVIDE SIGN AT EACH ROOM
ENTRY DOOR AS NOTED AND
EACH EXIT AS FOLLOWS:
SIGNAGE NOTES:
1. SEE SPECIFICATIONS FOR SPECIFIC SIGNAGE DETAILS,
DIMENSIONS, FONT, COLORS, MATERIALS, ETC.
2. ALL SIGNAGE INDICATED BELOW SHALL COMPLY WITH ICC
A117.1.
ROOM SIGNAGE
UNISEX
6"
6"
3"
PICTOGRAMS
BRAILLE CHARACTERS
C
UNISEX HC
RESTROOM
5/8" MIN. - 2" MAX. HEIGHT
1/32" RAISED CHARACTERS
UPPERCASE, SANS SERIF
ROOM SIGN PANEL TO BE POSTED ADJACENT TO THE LATCH SIDE OF
THE DOOR, 60 INCHES ABOVE THE FINISH FLOOR TO THE CENTERLINE
OF THE SIGN. 18" X 18" CLEAR FLOOR SPACE CENTERED ON TACTILE
CHARACTERS SHALL BE PROVIDED
EXIT
1" TALL, 1/32" RAISED
CHARACTERS, UPPER-
CASE, SAN SERIF
6"
1/
2"
BRAILLE
CHARACTERS
E
EXIT
ROOM NAME
3/4" TALL, 1/32" RAISED
CHARACTERS, UPPER-CASE,
SAN SERIF. VERIFY ROOM
NAMES WITH ARCHITECT
BEFORE PRODUCTION.
6"
1/
2"
BRAILLE CHARACTERS
D
ALL OTHER
ROOMS
6"
1/
2"
1/
2"
NOTICE
FOR YOUR SAFETY
OCCUPANCY
IS LIMITED TO
PERSONS
BY ORDER OF THE CODE
OFFICIAL
Keep Posted Under Penalty Of Law
5/8" TALL CHARACTERS
3/8" TALL CHARACTERS
5/8" TALL CHARACTERS
3/8" TALL CHARACTERS
5/8" TALL CHARACTERS
3/8" TALL CHARACTERS
1/4" TALL CHARACTERS
F
ASSEMBLY
ROOM
3.
EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY HAVING AN
OCCUPANT LOAD OF 50 OR MORE SHALL HAVE THE OCCUPANT LOAD OF THE
ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT.
A
B
D
E
STORAGE
ELEC. DATA CLOSET
BASEMENT BATHROOM
C
D
E
E
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
9/
/2
7:
:4
A
M
09/30/2024
A003
GENERAL INFORMATION
5765 W Broadway St. Missoula, MT 59808
AFD VISITOR CENTER
REMODEL
C O
N S
T R
U C
T
IO
N S
E T
1/8" = 1'-0"
LEVEL 1 SIGNAGE PLAN
1/8" = 1'-0"
BASEMENT SIGNAGE PLAN
5/8" GYPSUM BOARD
TYPE X
i1a- 4" STUD FRAMING i1b- 6" STUD FRAMING
5/8" GYPSUM BOARD
TYPE X
3 1/2" ACOUSTICAL
BATT INSULATION
NOTE: SEE ELEVATIONS AND FINISH SCHEDULES FOR
WALL FINISHES, TYPICAL ALL WALL TYPESINTERIOR WALL TYPES
INTERIOR PARTITION
NON-RATED SOUND WALL
5/8" GYPSUM
BOARD TYPE X
5/8" GYPSUM
BOARD TYPE X
INTERIOR PARTITION
NON-RATED
i1_ i2_
2X6 WD STUDS @ 16"
O.C.
5/8" GYPSUM BOARD
TYPE X
CLOSED CELL SPRAY
INSULATION - 4.5" MINIMUM
INTERIOR FURR WALL
FURRED WALL
i3 i2a- 4" STUD FRAMING i2b- 6" STUD FRAMING
5/8" GYPSUM BOARD TYPE X
6" STUD FRAMING
5/8" GYPSUM BOARD TYPE X
5 1/2" FIBERGLASS
INSULATION
LULA SHAFT WALL
1 HR RATED WALL
i4 i4PLY -ADD 3/4" PLYWOOD @
LOCATIONS INDICATED IN PLAN
i4PLY
1 HR RATED WALL- W/ 3/4" PLYWOOD
FLOOR ASSEMBLY
FINISH FLOOR- SEE FINISH PLAN
EXISTING STRUCTURE
7/8" HAT CHANNEL - MECHANICALLY
ATTACH TO CONCRETE T
FLOOR ASSEMBLY
FA2
5/8" GWB CEILING
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
9/
/2
7:
:4
A
M
09/30/2024
A004
ASSEMBLY TYPES
5765 W Broadway St. Missoula, MT 59808
AFD VISITOR CENTER
REMODEL
C O
N S
T R
U C
T
IO
N S
E T
1 1/2" = 1'-0"
INTERIOR WALL TYPES (WOOD)
1. DETERMINE LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO
DEMO, EXCAVATION OR PLANTING. MAINTAIN 10' MIN DISTANCE FROM
ALL TREES TO UTILITY LINES.
2. PROTECT ALL EXISTING ITEMS/SURFACES TO REMAIN. EXISTING
ELEMENTS DAMAGED DURING CONSTRUCTION TO BE REPAIRED OR
REPLACED BY CONTRACTOR AS DIRECTED BY THE CO AT NO COST TO
OWNER.
3. PROTECT EXISTING TREES WITH TEMPORARY CONSTRUCTION FENCE
LOCATED 3 FEET OUTSIDE DRIP LINE, PROTECT OVERHANGING LIMBS
FROM DAMAGE AS REQUIRED.
4. SITE GRADING IS BASED ON FINISH FLOOR ELEVATION OF 100.00 IS
EQUAL TO SITE GRADE OF ####.# FEET
GENERAL SITE PLAN NOTES
NEW CONSTRUCTION
EXISTING ELEMENTS TO REMAIN
LINEWORK LEGEND
EXISTING BUILDING
ROOF LINE OVERHEAD
NEW SCREEN FENCE
NEW CONCRETE WALKWAY
NEW CONCRETE WALKWAY- SEE CIVIL
EXISTING CONCRETE WALKWAY -
RETAIN & MEET NEW POUR TO MATCH GRADE
/4
A101
SIM
A501
A501
A
BELSON OUTDOORS
NEW HAVEN COLLECTION PARK BENCH
6' LENGTH - WHITE FRAME
A101
Sim
EXISTING FENCE
BID ALT # 1- LANDMARK SIGN-
FINAL LOCATION TO BE DETERMINED &
COORDINATED WITH DOT REQUIREMENTS
ˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍ
A101A
Sim
(E) DOWNSPOUT
N
ADA BUTTON POLE
A
ROAD
CONCRETE PAD @ EXTERIOR DOOR
EXISTING LOOKOUT
TOWER TO BE
RELOCATED HERE AS
PART OF FUTURE
CONTRACT.
FIRETOWER REASSEMBLY
AND FUTURE RAMP NIC.
FUTURE FENCE FOR
FIRETOWER EXHIBIT- NIC
Level 1
109' - 4"
CAST IN PLACE POST BASE
2X4 CROSS BEAM
4X4 POST
5/8" x 5 1/2" CEDAR
FENCE BOARDS SQUARE
CUT TOP W 1/2" GAP-
PAINT P2 TO MATCH
WOOD FACADE
4" 1'
0"
3'
6" 6"
EXISTING BUILDING
1/8"
NEW WEED MAT TO BE LAID THROUGHOUT
LANDSCAPED AREA - COVER WITH
SHREDDED CEDAR MULCH
NEW IRRIGATION INSTALLED THROUGHOUT
SITE. SEE CIVIL DRAWINGS
N
NEW WEED MAT TO BE LAID
THROUGHOUT LANDSCAPED AREA -
COVER WITH SHREDDED CEDAR MULCH
NEW WEED MAT TO BE LAID
THROUGHOUT LANDSCAPED AREA -
COVER WITH SHREDDED CEDAR MULCH
20 SHRUBS AT LEAST 2’ IN DIAMETER TO BE PLACED
ACROSS THE SITE- COORDINATE LOCATION WITH FS.
TWO EVERGREEN TREES MINIMUM 4” CALIPER TO BE
PLACED TO THE WEST SIDE OF THE BUILDING
EXISTING BUILDING
SIDEWALK DEMO- SEE CIVIL
ROOF LINE OVERHEAD
REMOVE RUSSIAN
OLIVE TREE IN ITS
ENTIRETY
ALL LANDSCAPING TO BE
REMOVED FOR GRADING/
DRAINAGE- SEE CIVIL
REMOVE THIS PORTION OF SIDEWALK- SEE CIVIL FOR
ADDITIONAL AREAS OF PAVEMENT DEMOLITION
REMOVE OVERGROWN GRASSES
THROUGHOUT ALL AREAS
REMOVE SHRUBS- COORD W/
FOREST SERVICE
LARGE EVERGREEN
TREES TO BE REMOVED
EXISTING FENCE
N
DEMO & REPLACEMENT OF PATIO
SLAB- BID ALT #2- SEE CIVIL
ALL LANDSCAPING
TO BE REMOVED
5 1/4" 5/8"
2X4 CROSS BEAM - TREATED CEDAR
4X4 POST- TREATED CEDAR
5/8" x 5 1/2" CEDAR FENCE BOARDS
SQUARE CUT TOP W 1" GAP- PAINT
P2 TO MATCH WOOD FACADE
5/8"
4" 7'
0"
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
9/
/2
7:
:4
A
M
09/30/2024
A101
SITE PLAN
5765 W Broadway St. Missoula, MT 59808
AFD VISITOR CENTER
REMODEL
C O
N S
T R
U C
T
IO
N S
E T
3/32" = 1'-0"
SITE PLAN
1/2" = 1'-0"
NEW FENCE DETAIL
3/32" = 1'-0"
LANDSCAPE & IRRIGATION PLAN
1" = 20'-0"
SITE PLAN DEMO
1/4" = 1'-0"
SITE BENCH
1/4" = 1'-0"
FENCE ELEVATION
4'-5"
1' -0
DOUBLE MAT #4 BARS @
12" O.C. EACH WAY, SEE
STRUCTURAL FOR PLACEMENT
REQUIREMENTS
12" COMPACTED
ROAD MIX
8"
SLOPE TOP STONES
MIN. 2% TO OUTSIDE. PROVIDE
FLUSH MORTAR JOINTS ON TOP
W/ EPOXY MORTAR
DRYSTACK LOOK LEDGER
STONE SIDE WALLS, BATTERED
AS SHOWN
#4 @ 32" VERTICAL IN 8"
CMU BACKER BLOCK
FOREST SERVICE BRASS
PLAQUE MOUNTED ON
STAINLESS STUDS
SIGN PANEL,
SEE DETAIL
CRITICAL NOTE: SIGN TO BE 2 SIDED.
OPTION ITEM #1: ENTRY SIGN
8'-9"
4' -0
/4
7'-7"
2'-7"
1' -6
SMOKEJUMPER VISITOR CENTER
AERIAL FIRE DEPOT
1' -0
2'
-0
3' -4
100.00°
8"
4 1/2"
2'-4"
4 1/2"
8"
CAST BRONZE
18" FOREST SERVICE
SHIELD, CONTACT FS
FOR REQUIREMENTS
PAINTED WESTERN RED
CEDAR PLANK SIGN W/
ROUTERED LETTERING
SIGN LETTERING SHOWN FOR BID
PURPOSES ONLY. OWNER TO PROVIDE
FINAL EXACT LAYOUT, VERBAGE, AND FONT PRIOR
TO MANUFACTURING OF SIGNAGE
A101A
Sim
13'-0" 8"
(4) 8" X 42" CONCRETE
SONOTUBES W/ (4) #4
EACH
12" CONCRETE SLAB
W/ #4 @ 12" O.C.
EACH WAY
TW0-TONE PAINT
TO WRAP TO BACKSIDE
CRITICAL NOTE: THESE DETAILS ARE PROVIDED FOR BIDDING
PURPOSED AND GENERAL DESIGN. SIGNAGE CONSTRUCTION MUST
FOLLOW THE REQUIREMENTS OF USDA FOREST SERVICE SIGN AND POSTER
GUIDELINES FOR FOREST SERVICE.
R10" R10
R1'
- 0
" R1' - 0"
100.00°
OPTION ITEM #1: ENTRY SIGN
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
9/
/2
7:
:4
A
M
09/30/2024
A101A
SITE- LANDMARK SIGN- OPTION
ITEM #1
5765 W Broadway St. Missoula, MT 59808
AFD VISITOR CENTER
REMODEL
C O
N S
T R
U C
T
IO
N S
E T
3/4" = 1'-0"
ENTRY SIGN - SECTION
3/8" = 1'-0"
ENTRY SIGN - ELEVATION
DN
DN
STAIR TREADS IN THIS AREA CONTAIN ASBESTOS. REFER TO ASBESTOS
REPORT FOR ADDITIONAL INFORMATION PRIOR TO DEMOLITION
WALLS IN THIS AREA CONTAIN ASBESTOS.
REFER TO ASBESTOS REPORT FOR ADDITIONAL
INFORMATION PRIOR TO DEMOLITION
NEW RADON PIPING TO
BE INSTALLED IN THIS
AREA. SEE PLUMBING
PLAN 1/P100
DEMOLITION KEYNOTES
NOTE: SEE MECH/ELEC/STRUCT AND CIVIL DRAWINGS FOR ADDITIONAL DEMOLITION
INFORMATION.
REMOVE EXISTING INTERIOR WALL COMPLETELY, INCLUDING BRACING ABOVE CEILING
WHERE OCCURS. PROTECT CEILING AND FINISH. REPAIR ALL ADJACENT SURFACES TO
RECEIVE NEW FINISHES.
REMOVE DOOR, FRAME AND HARDWARE.
NOT USED
REMOVE SUSPENDED CEILING SYSTEM, INCLUDING ALL ASSOCIATED SUPPORT CABLE &
PERIMETER T-BAR. COORDINATE EXTENT OF DEMOLITION WITH REMODEL PLANS.
REMOVE ALL ASSOCIATED LIGHT FIXTURES, DIFFUSERS AND RETURN GRILLES. LEAVE
ANY SMOKE DETECTORS ACTIVATED & DANGLING AFTER CEILING REMOVAL FOR
REINSTALLATION. ENSURE DUCTWORK TO REMAIN IS PROPERLY SUPPORTED.
REMOVE LIGHT FIXTURE - SEE MEP.
NOT USED
REMOVE WOOD WALL COVERING & ALL SHELVES ON SURFACE
REMOVE EXISTING FLOORING AND PREPARE FOR INSTALLATION OF NEW FLOORING.
REMOVE EXISTING CASEWORK, COUNTERTOP & RELATED COMPONENTS.
REMOVE EXISTING TOILET PARTITION AND RELATED COMPONENTS.
REMOVE EXISTING PLUMBING FIXTURE & RELATED COMPONENTS.
REMOVE ELECTRICAL PANEL & CONDUIT PER ELECTRICAL.
NOT USED
ALL MUSEUM EXHIBITS TO BE CAREFULLY REMOVED OR PROTECTED AND SAVED FOR
REINSTALL. REPAIR ANY DAMAGE MADE TO EXHIBITS DURING CONSTRUCTION.
COORDINATE WITH FOREST SERVICE
WOODEN 2X CEILING GRID TO BE ENTIRELY REMOVED
SCREEN AND BOARD TO BE REMOVED- PRESENT TO OWNER PRIOR TO DISPOSAL
NOT USED
HANDRAIL TO BE REMOVED- PREP AREA FOR NEW INSTALL
DISPLAY CASE CONTENETS TO BE REMOVED BY FOREST SERVICE PRIOR TO
DEMOLITION. COORDINATE WITH FOREST SERVICE.
STOREFRONT TO BE REMOVED- OPENING TO BE EXPANDED TO ORIGINAL SIZE.
PROTECT SURROUNDING WALL FINISHES
REMOVE DOOR, FRAME, AND HARDWARE. WALL TO BE INFILLED TO MATCH
SURROUNDING WALL CONSTRUCTION
1. VERIFY ALL CONDITIONS AND COORDINATE WITH ALL DISCIPLINES OF
CONTRACT. UNDOCUMENTED FIELD CHANGES MAY HAVE OCCURRED AND ARE
TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT WHEN DISCOVERED.
2. SEE CIVIL DRAWINGS FOR SITE DEMOLITION.
3. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR DEMOLITION
WORK OF THOSE TRADES.
4. WHERE DEMOLITION IS INDICATED, WALLS SHALL BE REMOVED AND CEILING
SHALL BE PATCHED, REPAIRED AND PAINTED TO MATCH EXISTING.
5. CONTRACTOR SHALL MAINTAIN A TEMPORARY WEATHER TIGHT ENCLOSURE
AS ITEMS ARE BEING REMOVED.
6. COORDINATE ALL MECHANICAL, ELECTRICAL, FIRE SYSTEMS,
COMMUNICATIONS AND UTILITY SHUT-DOWNS WITH OWNER PRIOR TO
REMOVING AND OR RELOCATING.
7. DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN ON
DRAWINGS. THE INTENT IS TO INDICATE THE GENERAL SCOPE OF
DEMOLITION REQUIRED TO COMPLETE THE WORK IN ACCORDANCE WITH THE
CONTRACT DRAWINGS.
8. THESE DRAWINGS INDICATE STRUCTURAL AND NON-STRUCTURAL
DEMOLITION THAT IS TO OCCUR TO MAKE WAY FOR NEW CONSTRUCTION.
ADDITIONAL STRUCTURAL DEMOLITION WORK, CONSTRUCTION OR SHORING
REQUIRING COORDINATION WITH NEW STRUCTURAL IS INDICATED ON THE
STRUCTURAL DRAWINGS.
9. EXISTING OPENINGS IN WHICH MECHANICAL AND PLUMBING ARE REMOVED IN
A CONCRETE SLAB SHALL BE FILLED WITH AN EPOXY-BASED TWO-
COMPONENT CEMENTITIOUS TROWEL-GRADE MORTAR. OPENINGS SHALL BE
FORMED AND MATERIAL PLACED IN OPENINGS OF 12"X12" SQ/DIA OR LARGER,.
CONTRACTOR SHALL PROVIDE #4 DOWELS AT 8" O.C. EACH WAY IN OPENINGS.
CONTRACTOR SHALL EPOXY MORTAR/CHEM. AND ADHESIVE SET DOWELS
INTO EXISTING CONCRETE WITH 4" MIN. EMBED.
10. SEE HAZARDOUS MATERIALS ABATEMENT DRAWINGS FOR ADDITIONAL
INFORMATION AND COORDINATION.
GENERAL DEMOLITION NOTES
DEMOLISHED ELEMENTS
EXISTING ELEMENTS TO REMAIN
LINEWORK LEGEND
28' - 4" 5' - 0" 8' - 8 3/4"
1'
8"
14 14
REMOVE PAINT AS NECESSARY- REPAIR
& PREP ALL COLUMNS FOR REPAINTPROVIDE WOOD FILL OR REPLACE
BATTENS WHERE DAMAGED - PREP
WOOD SCREEN FACADE FOR PAINT
1 WALL TO BE REMOVED
TO FIRST FLOOR LEVEL
REPAIR & PREP CMU FACADE
FOR PAINT- TEST PAINT FOR
LEAD PRIOR TO DEMO.
REPAIR & PREP CMU
FACADE FOR PAINT
REPAIR & PREP CMU
FACADE FOR PAINT
DRAWINGS FOR RESTORATION OF
FIRETOWER BY FOREST SERVICE.
FIRETOWER TO BE DISASSEMBLED
& REASSEMBLED IN ADDITION.
ENTRY TO FIRETOWER TO BE MADE
ACCESSIBLE AS PART OF REINSTALL
REPAIR & PREP CMU FACADE FOR
PAINT- ASBESTOS HAS BEEN
FOUND ELSEWHERE IN BUILDING.
TEST PAINT PRIOR TO DEMO.
WALLS IN THIS AREA
CONTAIN ASBESTOS. REFER
TO ASBESTOS REPORT FOR
ADDITIONAL INFORMATION
PRIOR TO DEMOLITION
CEILING IN THIS AREA
CONTAINS ASBESTOS. REFER
TO ASBESTOS REPORT FOR
ADDITIONAL INFORMATION
PRIOR TO DEMOLITION
REMOVE PAINT FROM T&G
SOFFIT- PREP FOR STAIN
REMOVE PAINT FROM GLULAM
BEAMS- PREP FOR STAIN
REMOVE PAINT FROM GLULAM
BEAMS- PREP FOR STAIN
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
9/
/2
7:
:4
A
M
09/30/2024
A102
DEMOLITION PLAN
5765 W Broadway St. Missoula, MT 59808
AFD VISITOR CENTER
REMODEL
C O
N S
T R
U C
T
IO
N S
E T
1/8" = 1'-0"
BASEMENT DEMOLITION PLAN
1/8" = 1'-0"
LEVEL 1 DEMOLITION PLAN
N
N
1/8" = 1'-0"
RCP - FIRST FLOOR DEMO PLAN
3 1/8" = 1'-0"
RCP - BASEMENT DEMO PLAN
N
N
DN
1. DIMENSIONS ARE TO FACE OF STUD, EXISTING WALL FINISH,
MASONRY, OR DOOR/WINDOW OPENINGS. DIMENSIONS OF EXISTING
CONSTRUCTION ARE NOT SHOWN ON DRAWINGS - VERIFY
DIMENSIONS OF ALL EXISTING CONSTRUCTION IN THE FIELD.
DIMENSIONS TO OPENINGS ARE NOMINAL. VERIFY ALL OPENINGS
WITH ROUGH OPENING REQUIREMENTS.
2. ALL DOOR OPENINGS PERPENDICULAR TO A WALL ARE 4" TO THE
WALL FRAMING UNO.
3. EXISTING CONSTRUCTION TO REMAIN SHOWN SHADED, NEW
CONSTRUCTION SHOWN SOLID.
4. SEE SHEET A-002 FOR WALL TYPES. IN AREAS WITH SUSPENDED
ACOUSTICAL TILE CEILINGS, GYPSUM WALL BOARD MAY BE
TERMINATED 6" ABOVE THE CEILING. IN AREAS WITH EXPOSED
STRUCTURE CONTINUE GYPSUM BOARD TO UNDERSIDE OF
STRUCTURE.
5. VERIFY EXISTING WALL CONSTRUCTION.
6. ALL EGRESS DOORS SHALL BE READILY OPERABLE FROM THE
EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE
OR EFFORT.
GENERAL FLOOR PLAN NOTES
NEW CONSTRUCTION
EXISTING ELEMENTS TO REMAIN
LINEWORK LEGEND
A201
A201
A201
B
A
A
1 1
4 4
A302
A302 i2a i3 i3 i3 i3
WOMEN
MENS
RECEPTION & GIFT SHOP
NEW ADA
DOOR
OPERATION
BUTTON
A
A801
ˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍ
A103
JANITOR
i2ai2a
REINSTALL EXHIBITS- COORDINATE
WITH FOREST SERVICE/CO FOR
REQ. REVISIONS TO EXHIBIT
F 01
F 02
F 03
WALL TO BE INFILLED TO
MATCH SURROUNDING
WALL CONSTRUCTION
WATER FOUNTAIN
W/ BOTTLE FILL-
CENTERED
A
B
ˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍ
A501 i3
EXISTING EXHIBIT
HALF WALL @ 52"
A801
A
NEW WALL MOUNTED
HANDRAIL- BOTH SIDES
FULL HEIGHT WALL
A
A302
A302
A501
ˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍ
A504
A504
S 01
ˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍ
A501
SIM
3'
3/
4" i3
A701
EXISTING LOOKOUT TOWER TO BE
RELOCATED HERE AS PART OF
FUTURE CONTRACT.
FIRETOWER REASSEMBLY AND
FUTURE RAMP NIC.
VL
NEW RAIL FOR INCLINED
STAIR LIFT- SEE MANF.
"10
0" 4'
6"
NEW CONCRETE SLAB
4' - 6"
7' - 6"
FUTURE FENCE FOR FIRETOWER EXHIBIT- NIC
B
A302
A801
A
A i2b
36X80
36X80
5'X5' ACCESSIBLE STALL
2'
0" 6'
4"
WOMEN
MENS
X8
A801
A i1b i1b i1b i2b i2ai2a
PRIVACY SCREEN
2'
1/
4" 4'
6'
0"
6' - 10" 10' - 7"
4' - 1" 1' - 9" 11' - 7"
DRINKING FOUNTAIN W/
BOTTLE FILL- CENTERED
2'
6" 1'
4"
5'X5' ACCESSIBLE STALL
i2b
1' - 10" 2' - 9"
3' - 0" 1' - 8"
3' - 2" 3' - 6"
1' - 6"
1' - 6"
5' - 2 1/2" 3' - 0" 3' - 0"
F 01
F 02
F 03
1'
0"
3'
0"
1'
7" i2a i3
5'
5/
8"
2'
1/
2" i3
ENTIRE LOOKOUT TOWER TO BE DECONSTRUCTED AND
REMOVED FROM THE EXISTING BUILDING BY CONTRACTOR,
LOOKOUT TOWER WILL THEN BE STORED IN THE MISSOULA
AREA AS DIRECTED BY THE PROJECT CO.
BRIEF DESCRIPTION OF WORK
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
9/
/2
7:
:5
A
M
09/30/2024
A103
FLOOR PLAN
5765 W Broadway St. Missoula, MT 59808
AFD VISITOR CENTER
REMODEL
C O
N S
T R
U C
T
IO
N S
E T
3/16" = 1'-0"
LEVEL 1 FLOOR PLAN
N
3/8" = 1'-0"
ENLARGED BATHROOM PLAN
LOOKOUT TOWER
12" = 1'-0"
EXISTING LOOKOUT TOWER IMAGES
CAULK SEAMS- COLOR TO
MATCH SURROUNDING WALL
5/8" GYP BD.
CAULK SEAMS- COLOR TO
MATCH SURROUNDING WALL
5/8" GYP BD.
5/8" GYP BD.
PAINT COLUMN TO MATCH
SURROUNDING WALL
GYP BD
PFM FRAME BACK
TO PANEL,
MEASURE IN
FIELD - MITER
CORNERS, WHITE
(E) ELEC. PANEL
2"
RF1
LVT STAIR NOSING- NOSING TO
COMPLETELY COVER TREAD
FASTEN PER
MANF DIRECTIONS
EXISTING STAIR
RF1
1" CIRCULAR RAIL - WHITE
1" CIRCULAR RAIL - WHITE
1 1/2" CIRCULAR RAIL- WHITE
1" CIRCULAR BALUSTER- WHITE
M
AX4"
1'
/2
4" 4"
3'
0"
3" X 3" PLATE WELDED TO
BOTTOM OF POST
(4) COUNTERSUNK FASTENERS PER POST
5/8" PLYWOOD
RF 1
RF 1
5/8" PLYWOOD
1" CIRCULAR RAIL - WHITE
B
B
A
A
1 1
4 4 i3 i3 i3
A302
A302
STORAGE
N
MAIN
DATA
CLOSET
A
HANDRAIL TO EXTEND
1'-0" PAST STAIR
1' - 0"
ELEC.
CLOSET
A302
A302
F 06
FL
5' - 11 3/4" 2' - 9 3/4" 4' - 0 1/4"
9'
0" i2a i2a i2b
ˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍ
A104 i2a ˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍ
A104
ˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍ
A104
SIM
A104
ELEC. DATA CLOSET
BASEMENT BATHROOM
i3 i3 i3
2'
8" 4'
1/ 2"
4' - 0"
1'
6"
RADON PIPING BELOW
SLAB- REF 10/P003
STAIR LIFT DRIVE
BOX MOUNTED AT
CEILING HEIGHT-
SEE MANF. REC.
i1c
1'
4' - 9"
STAIR LIFT -
GARAVENTA ATRIA-
LIFT TO BE STORED
AT BOTTOM OF
STAIRS - SEE MANF.
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
9/
/2
7:
:5
A
M
09/30/2024
A104
BASEMENT PLAN
5765 W Broadway St. Missoula, MT 59808
AFD VISITOR CENTER
REMODEL
C O
N S
T R
U C
T
IO
N S
E T
3/16" = 1'-0"
BASEMENT FLOOR PLAN
1" = 1'-0"
WALL TO COLUMN CONNECTION
3 1" = 1'-0"
FURR WALL AT (E) PANELS
1 1/2" = 1'-0"
STAIR NOSING DETAIL
1 1/2" = 1'-0"
STEEL GAURDRAIL DETAIL
BA
GWB
8' - 3 1/2"
GWB
8' - 3 1/2"
GWB
8' - 3 1/2"
GWB
8' - 3 1/2"
GWB
8' - 3 1/2"
GWB
8' - 3 1/2"
T&G ROOFING- FINISHED AND STAINED
TO MATCH EXISTING
CEILING LAYOUT NOTES: LAY-IN CEILINGS ARE SHOWN CONCEPTUALLY.
IT IS THE INTENT THE CEILINGS AREA CENTERED WITHIN THE ROOM. IN
ODD SHAPED ROOMS, PRIMARY VISUAL AREA TO BE CENTERED. CEILNG
INSTALLER SHOULD CONSULT WITH THE CO IN THE FIELD FOR ANY AREAS
IN WHICH THEY WOULD LIKE TO MODIFY THE LAYOUT FROM THAT SHOWN
ON THE PLAN. MODIFICATIONS MAY BE ALLOWED, AT THE DISCRETION
OF THE ARCHITECT, TO EASE INSTALLATION, SAVE CUTTING, OR
INCREASE VISUAL APPEAL.
CEILING LEGEND
GWB 5/8" TYPE "X" GYPSUM WALLBOARD ON
STL. FRAMING - SEE DETAILS. PAINT P1
UNO
NEW CONSTRUCTION
EXISTING ELEMENTS TO REMAIN
LINEWORK LEGEND
1. GENERALLY CENTER CEILING GRIDS IN EACH ROOM AS SHOWN
ON PLANS TO PROVIDE EQUALLY SIZED PANELS ON OPPOSITE
WALLS. IF PLANS INDICATE A GRID ALIGNING WITH A COLUMN,
WALL, SOFFIT, ETC., START GRID AT INDICATED SURFACE.
2. SEE FLOOR PLAN FOR WALL TYPES AND WALLS THAT EXTEND
FULL HEIGHT TO STRUCTURE.
3. SEE TYPICAL DETAILS THIS SHEET.
4. CEILING FIXTURES ARE SHOWN FOR REFERENCE ONLY FOR
COORDINATION WITH CEILING FINISH SYSTEM. SEE MECHANICAL,
ELECTRICAL AND SPRINKLER DRAWINGS FOR ALL CEILING
FIXTURES AND TYPES.
5. SPOT ELEVATIONS ARE FROM FINISH FLOOR TO SURFACE FINISH
OF CEILING AND ARE ROUNDED TO THE NEAREST INCH.
GENERAL CEILING NOTES
BA
/8
/8
GYP BD
8' - 8"
EXISTING WOOD CEILING -
SAND, REPAIR AND RESEAL
EXISTING WOOD CEILING -
SAND, REPAIR AND RESEAL
ALL EXISTING ELECTRICAL OPENINGS IN CEILING TO BE REPAIRED
TO MATCH CEILING - ALL OPENINGS NOT SHOWN IN DRAWINGS
GYP BD
8' - 8"
GYP BD
9' - 6"
GYP BD
8' - 8"
GYP BD
8' - 8"
22x30
22x30
ACCESS DOOR
ACCESS DOOR
1" 2'
8"
SET SOFFIT FACE 1" BACK
FROM FACE OF GLULAM
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
9/
/2
7:
:5
A
M
09/30/2024
A106
REFLECTED CEILING PLAN
5765 W Broadway St. Missoula, MT 59808
AFD VISITOR CENTER
REMODEL
C O
N S
T R
U C
T
IO
N S
E T
3/16" = 1'-0"
RCP - BASEMENT
3/16" = 1'-0"
RCP - FIRST FLOOR
GWB ON 7/8" HAT CHANNELS
BA
1 1
4 4
EXISTING ROOF
(E) ROOF LINE ABOVE
ˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍ
A107
Sim
1. INSTALL SELF-ADHERING ICE BARRIER MATERIAL ON ALL EAVES AND
OVERHANGS FROM THE LOWEST EDGE OF ALL ROOF SURFACES TO A
POINT AT LEAST 36" INSIDE THE EXTERIOR WALL LINE OF THE
BUILDING.
2. INSTALL SELF-ADHERING ICE BARRIER MATERIAL AT ALL VALLEYS &
CHANGES IN ROOF SLOPE, 24" MIN. EACH SIDE OF TRANSITION.
3. PROVIDE TAPERED INSULATION CRICKET ON UPHILL SIDE OF ALL ROOF
CURBS/PENETRATIONS GREATER THAN 1'-0" WIDE.
4. GANG PLUMBING VENTS ABOVE CEILING TO MINIMIZE ROOF
PENETRATIONS. VERIFY PENETRATIONS IN FIELD. LOCATE
PENETRATIONS TO NOT BE VISIBLE FROM APPROACH TO FRONT ENTRY
WHERE FEASIBLE.
5. SEE MECHANICAL AND PLUMBING DRAWINGS FOR PIPING AND
EQUIPMENT PENETRATIONS. ALL PVC PIPE PENETRATIONS TO BE
PAINTED DARK GREY.
GENERAL ROOFING NOTES
NEW CONSTRUCTION
EXISTING ELEMENTS TO REMAIN
LINEWORK LEGEND
4 1/2"
1'-4"
1'- 5"
9"
4" OPEN
PREFINISHED SHT MTL
CONDUCTOR HEAD W/ 7"X4"
OVERFLOW
SET IN CONT SEALANT BEAD
PREFINISHED SHT
MTL CONDUCTOR
HEAD W/ 7"X4"
OVERFLOW- PAINT
6" x 3" DOWNSPOUT
ELEVATION
3/4" = 1'-0"
ISOMETRIC
3/4" = 1'-0"
0 0 05" 7" 5"
9"
PRE-MOLDED FLASHING
BOOT - WHITE
STAINLESS STEEL
WORM-GEAR CLAMP
PIPE PENETRATION -
WHITE
EXISTING ROOFING
ADHERE ROOF PATCH PER
MANF. RECCOMENDATION
SEAL & ADHERE BOOT
PER MANF. REC
SEALANT
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
9/
/2
7:
:5
A
M
09/30/2024
A107
ROOF PLAN
5765 W Broadway St. Missoula, MT 59808
AFD VISITOR CENTER
REMODEL
C O
N S
T R
U C
T
IO
N S
E T
1/8" = 1'-0"
ROOF PLAN
1 N 1 1/2" = 1'-0"
CONDUCTOR HEAD DETAIL
1 1/2" = 1'-0"
MEMBRANE ROOF PIPE PENETRATION
NEW CONSTRUCTION
EXISTING ELEMENTS TO REMAIN
LINEWORK LEGEND
Level 1
109' - 4"
B A
B
Upper Roof
122' - 10"
C
A302
VERTICAL WOOD SIDING- PAINT P2
WOOD COLUMNS- PAINT P3
GLULAM BEAM- STAIN S1
T&G SOFFIT - STAIN S1
5'
6" 1'
6"
ˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍ
A201
1. THIS LEGEND DOES NOT INCLUDE ALL MATERIALS. SEE NOTES
AND REFERENCED DETAILS FOR ADDITIONAL INFORMATION.
NOTES
MATERIALS LEGEND
CMU BLOCK (E)
VERTICAL WOOD SIDING (E)
Level 1
109' - 4"
A302
Upper Roof
122' - 10"
A
LOWER ROOF
118' - 4"
VERTICAL WOOD SIDING- PAINT P2
WOOD COLUMNS- PAINT P3
GLULAM BEAM- STAIN S1
T&G SOFFIT - STAIN S1
EXISTING CMU
BUILDING - PAINT P4
FENCE - PAINT P2
Level 1
109' - 4"
BA
WALL TO BE INFILLED TO
MATCH SURROUNDING
WALL CONSTRUCTION -
SEE STRUCT.
Upper Roof
122' - 10"
A302
4" 8"
ALT. COURSES OF 8X16 AND 4X16 BLOCKS
PROVIDE GROUT JOINT SIM TO EXISTING
EXISTING CMU BUILDING -
PAINT P4
EXISTING CMU BUILDING -
PAINT P4
FENCE - PAINT P2
Level 1
109' - 4"
1 4
A302
Upper Roof
122' - 10"
VERTICAL WOOD SIDING- PAINT P2
WOOD COLUMNS- PAINT P3
GLULAM BEAM- STAIN S1
T&G SOFFIT - STAIN S1
EXISTING CMU BUILDING -
PAINT P4
A502
Sim
A502
Sim
A502
Sim
1'
6"
10' - 6"
WESTERN RED CEDAR PLANK SIGN-
PAINTED FOREST SERVICE GREEN
ROUTERED LETTERING
SIGN LETTERING SHOWN FOR BID PURPOSES ONLY. OWNER TO PROVIDE FINAL
EXACT LAYOUT, VERBAGE, AND FONT PRIOR TO MANUFACTURING OF SIGNAGE.
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
9/
/2
7:
:5
A
M
09/30/2024
A201
EXTERIOR ELEVATIONS
5765 W Broadway St. Missoula, MT 59808
AFD VISITOR CENTER
REMODEL
C O
N S
T R
U C
T
IO
N S
E T
3/16" = 1'-0"
NORTH ELEVATION
3/16" = 1'-0"
EAST - ELEVATION
3/16" = 1'-0"
SOUTH - ELEVATION
3/16" = 1'-0"
WEST - ELEVATION
1/2" = 1'-0"
VISITOR CENTER SIGN
(E) BASEMENT
100' - 0"
Level 1
109' - 4"
B A
ELEC. DATA CLOSET
WOMEN
ˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍ
A101
FA 2
BASEMENT BATHROOM
STORAGE
RECEPTION & GIFT SHOP
ˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍˍ
A302
HALLWAY WALL TO EXTEND TO DECK
Level 1
109' - 4"
A
EXISTING WALL1/2" GAP
FRAMED FURR WALL
LAG INTO CONCRETE
SPRAY INSULATION
GYP BD
(E) BASEMENT
100' - 0"
Level 1
109' - 4"
1 4
A302
Upper Roof
122' - 10"
LOWER ROOF
118' - 4"
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
9/
/2
7:
:5
A
M
09/30/2024
A302
BUILDING SECTIONS
5765 W Broadway St. Missoula, MT 59808
AFD VISITOR CENTER
REMODEL
C O
N S
T R
U C
T
IO
N S
E T
3/16" = 1'-0"
SECTION @ EXISTING & NEW
1 1/2" = 1'-0"
INTERIOR WALL BASE DETAIL
# DATE REVISION
3/16" = 1'-0"
SECTION @ NEW4
1/4" LAMINATED SAFETY GLAZING
GLAZING LEGEND
EXISTING CMU BLOCKWALL
EXISTING WOOD SCREEN (PROTECT)
NEW WINDOW
1/2"
3"
1/2" 3/4"
PREMIUM GRADE FIR
W/ SATIN STAIN - COLOR TBD
BACKER ROD AND SEALANT
SEALANT & BACKERROD
WINDOW IN SEALANT BED
EXISTING CMU BLOCKWALL
EXISTING WOOD SCREEN TRIM TO
SLOPE FLASHING (PROTECT REMAINING)
BI-FOLD WINDOW
PFM FLASHING- MATCH
EXTERIOR PAINT COLOR-
SET IN SEALANT BED,
SLOPE AWAY FROM SILL
PREMIUM GRADE FIR
W/ SATIN STAIN - COLOR TBD
BACKER ROD AND SEALANT
3"
1/2" 3/4"
A501
A501
A501
A501
5'
0"
3' - 8"
BASIS OF DESIGN:
'WEATHER SHIELD'
BI-FOLD
A501
SIM
A501
SIM
WOOD FRAMED WINDOW
OUTSWING
CASEMENT
VERIFY EXISTING
OPENING IN FIELD
A501
A501
VERIFY EXISTING OPENING SIZE
11' - 5"
APPLIED
ARCHITECTURAL
MULLION
2' - 4 1/2" 6' - 8" 2' - 4 1/2"
EQEQEQ
WHITE STOREFRONT
VINYL PRINTED GRAPHIC-
WOOD GRAIN- OPAQUE-
VERIFY WITH HISTORIC
IMAGES/ARCH
VINYL PRINTED GRAPHIC-
LEAVES PATTERN-
TRANSPARENT - VERIFY WITH
HISTORIC IMAGES/ARCH
4X8 RECTANGULAR MULLION
1.75X5 HORIZONTAL MULLION
A501
SIM
2'
1/
2" 2'
1/ 2"
2'
1/
4" 2'
5/ 8"
2'
5/
8"
7'
0"
GYP. RETURN TO STOREFRONT
EXISTING WOOD CEILING
PFM FLASHING DRIP EDGE
BACKER ROD & SEALANT
FRAMED FURR WALL
APPLIED ARCHITECTURAL MULLION
GYP. RETURN TO STOREFRONT
BACKER ROD & SEALANT
FRAMED FURR WALL
WOOD ACCENT WALL- 2X2
SMOOTH SAWN BATTENS
WITH SATIN STAIN
WINDOW GRAPHIC ON INTERIOR- SEE ELEVATION
AND OWNER/ARCHITECT FOR GRAPHIC
GYP. RETURN TO STOREFRONT
SEE FINISH PLAN
FOR FLOORING
THERMALLY BROKEN
THRESHOLD SET IN BEDDING
SEALANT
(E) CONCRETE SLAB
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
9/
/2
7:
:5
A
M
09/30/2024
A501
WINDOW TYPES, WINDOW
DETAILS
5765 W Broadway St. Missoula, MT 59808
AFD VISITOR CENTER
REMODEL
C O
N S
T R
U C
T
IO
N S
E T
1 1/2" = 1'-0"
REPLACEMENT WINDOW HEAD DETAIL
1 1/2" = 1'-0"
REPLACEMENT WINDOW SILL DETAIL
71/4" = 1'-0"
WINDOW ELEVATION
BA C
1/2" = 1'-0"
NEW STOREFRONT
1 1/2" = 1'-0"
REPLACEMENT STOREFRONT HEAD
1 1/2" = 1'-0"
REPLACEMENT STOREFRONT JAMB
1 1/2" = 1'-0"
REPLACEMENT STOREFRONT SILL
Window Schedule Type Mark Description Type Sill Height Comments
A OUTSWING CASEMENT 2'3" x 5'7" 3' - 1" VERIFY EXISTING OPENING
B BI-Fold Exterior Window default 3' - 8" VERIFY EXISTING OPENING
DOOR TYPES
F
FLUSH
VL
VISION LIGHT
SEE PLAN AND SCHEDULE FOR ALL DOOR SIZES
1' - 8" 6"
6" 2'
8"
A
FF
H.M. FRAME
2"
SCHEDULE
PER 2"
2"
DOOR FRAME TYPES
SEE PLAN…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .