This is a construction detail drawing for a column base modification project. The document illustrates the specifications for retrofitting existing exterior columns with new Douglas Fir (D.F.) material at the base, with a total height of 4 feet 0 inches. The work includes removing the lower 12 inches of outside columns and replacing them with new #1 D.F. lumber, infilling between columns with #1 D.F. filler material measuring 3 1/2" by 4 17/32" by 4" in dimension.
The construction details specify multiple through-bolt installations with countersink and plug requirements: four 1/2" bolts at the base connection and two 1/2" bolts at three intermediate locations along the column height. Additional work includes replacing all 1/2" bolts, cleaning and sanding the existing base, and applying paint to prepared surfaces. The drawing designates new construction elements with solid lines and existing elements to remain with dashed lines, scaled at 1 1/2" = 1'-0" for the column base detail. All bolt connections require countersinking and plugging to provide a finished appearance.
View the file
Other files for this federal contract opportunity
Show all 21
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NEW CONSTRUCTION
EXISTING ELEMENTS TO REMAIN
LINEWORK LEGEND
1'
1/
EXISTING BASE, CLEAN,
SAND, PAINT
REPLACE 1/2" BOLTS
REMOVE LOWER 12" OF OUTSIDE
COLUMNS. REPLACE WITH NEW
#1 D.F.
4'
0"
INFILL BETWEEN COLUMNS
WITH #1 D.F. FILLER
1/
2"
/3
2" 4"
(4) 1/2" THRU BOLTS, COUNTER-
SINK AND PLUG
(2) 1/2" THRU BOLTS, COUNTER-
SINK AND PLUG
(2) 1/2" THRU BOLTS, COUNTER-
SINK AND PLUG
(2) 1/2" THRU BOLTS, COUNTER-
SINK AND PLUG
1 1/2" = 1'-0"
COLUMN BASE
| Sheets |
| A106 - REFLECTED CEILING PLAN |