Attachment 12 Column Base - Structural Fix.pdf

PDF 35 KB Posted

Attached to
AFD Visitor Center Remodel Federal contract opportunity
Solicitation number
1240LU26Q0022
Issued by
Department of Agriculture Forest Service

About this file

This is a construction detail drawing for a column base modification project. The document illustrates the specifications for retrofitting existing exterior columns with new Douglas Fir (D.F.) material at the base, with a total height of 4 feet 0 inches. The work includes removing the lower 12 inches of outside columns and replacing them with new #1 D.F. lumber, infilling between columns with #1 D.F. filler material measuring 3 1/2" by 4 17/32" by 4" in dimension.

The construction details specify multiple through-bolt installations with countersink and plug requirements: four 1/2" bolts at the base connection and two 1/2" bolts at three intermediate locations along the column height. Additional work includes replacing all 1/2" bolts, cleaning and sanding the existing base, and applying paint to prepared surfaces. The drawing designates new construction elements with solid lines and existing elements to remain with dashed lines, scaled at 1 1/2" = 1'-0" for the column base detail. All bolt connections require countersinking and plugging to provide a finished appearance.

View the file

Other files for this federal contract opportunity

Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NEW CONSTRUCTION

EXISTING ELEMENTS TO REMAIN

LINEWORK LEGEND

1'

1/

EXISTING BASE, CLEAN,

SAND, PAINT

REPLACE 1/2" BOLTS

REMOVE LOWER 12" OF OUTSIDE

COLUMNS. REPLACE WITH NEW

#1 D.F.

4'

0"

INFILL BETWEEN COLUMNS

WITH #1 D.F. FILLER

1/

2"

/3

2" 4"

(4) 1/2" THRU BOLTS, COUNTER-

SINK AND PLUG

(2) 1/2" THRU BOLTS, COUNTER-

SINK AND PLUG

(2) 1/2" THRU BOLTS, COUNTER-

SINK AND PLUG

(2) 1/2" THRU BOLTS, COUNTER-

SINK AND PLUG

1 1/2" = 1'-0"

COLUMN BASE

Sheets
A106 - REFLECTED CEILING PLAN

File details come from the government source that posted it. Updated .