This document provides details for an upcoming federal construction contract opportunity with the Department of Veterans Affairs. The solicitation will be for the construction only portion of the Expand Primary Care Clinic project at the Newington VA Medical Center in Newington, Connecticut. The project scope involves renovating and expanding existing primary care clinic space by approximately 25,000 square feet through renovations and new construction. Relocation of several medical departments is also included. The solicitation will be issued as an Invitation for Bid to SDVOSB concerns only, with a magnitude between $5-10 million. The period of performance is approximately 600 days from notice to proceed. The pre-solicitation notice provides relevant acquisition details such as issuing office contacts, NAICS code, size standard, and response submission requirements to inform interested vendors in advance of the upcoming solicitation planned for issue on March 31, 2020.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROPOSEDEXISTING
CONTOUR LINE
CATCH BASIN
SANITARY LINE
STORM LINE
WATER LINE
WATER VALVE
UTILITY MANHOLE
SPOT GRADE
ELECTRIC LINE
ROOF LEADER
LIGHTING FIXTURE
YARD DRAIN
SANITARY CLEANOUT
LIGHT BOLLARD
STORM CLEANOUT
thr ee in ch es on e f oo t
6" on e a nd on e h alf in ch es on e f oo t 6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A R C H I T E C T S, I N C .
EXPAND PRIMARY CARE -
NEWINGTON VAMC
NEWINGTON, CT
689-402
JUNE 7, 2019 RL FV
1, 2, 3, 42
Department of Veterans Affairs
MARTINEZ COUCH & ASSOCIATES, LLC
SKILLED PROFESSIONALS.
PRACTICAL SOLUTIONS.
1084 Cromwell Avenue, Suite A-2 Rocky Hill, CT 06067 Tel: 860-436-4364
MartinezCouch.com
MCA Consulting Engineers & Surveyors DBE/MBE Certified
Site/Civil Engineering | Land Surveying | Energy & Sustainability Wastewater Engineering | Mechanical/Electrical/Plumbing | GIS
CD101
DEMOLITION PLAN
PROTECT EXISTING CONCRETE PAD AND ELECTRIC TRANSFORMER
TO REMAIN. ANY DAMAGES TO THE PAD OR TRANSFORMER MUST
BE IMMEDIATELY REPORTED TO THE CONTRACTING OFFICER'S
REPRESENTATIVE AND REPAIRED BY APPROVED METHODS AT THE
CONTRACTOR'S EXPENSE.
PROTECT EXISTING STAIRS TO REMAIN. ANY
DAMAGES TO THE STAIRS MUST BE IMMEDIATELY
REPORTED TO THE CONTRACTING OFFICER'S
REPRESENTATIVE AND REPAIRED BY APPROVED
METHODS AT THE CONTRACTOR'S EXPENSE.
PROTECT EXISTING WALL TO REMAIN. ANY
DAMAGES TO THE WALL MUST BE REPORTED
IMMEDIATELY TO THE CONTRACTING OFFICER'S
REPRESENTATIVE AND REPAIRED BY APPROVED
METHODS AT THE CONTRACTOR'S EXPENSE.
CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT
ALL DISCONNECTED UTILITIES THAT WILL REMAIN IN
USE WILL BE RECONNECTED OUTSIDE OF THE NEW
ADDITION FOOTPRINT. THIS INCLUDES, BUT NOT
LIMITED TO: STORM DRAINAGE, SANITARY SEWER,
WATER, GAS, ELECTRIC, COMMUNICATIONS, AND
OTHER.
REMOVE AND DISPOSE OFF SITE EXISTING
STORM CLEANOUT. VOID TO BE FILLED
WITH STRUCTURAL FILL AND COMPACTED
AS NECESSARY (TYP. FOR ALL ON SITE
STORM CLEANOUTS)
CLEAR AND GRUB EXISTING TREES (TYPICAL FOR ALL TREES WITHIN
THE HATCHED AREA). VOID TO BE FILLED WITH STRUCTURAL FILL
WITHIN PROPOSED ADDITION FOOTPRINT AND WITH COMMON FILL
WITHIN REMAINING AREA AND COMPACTED AS NECESSARY.
CONSTRUCTION LIMIT
(TYP.)
SAW CUT, DEMOLISH, AND DISPOSE OFF SITE EXISTING CONCRETE
WALKS, AND PADS (TYPICAL FOR ALL WALKS WITHIN THE HATCHED
AREA). VOID TO BE FILLED WITH STRUCTURAL FILL WITHIN PROPOSED
ADDITION FOOTPRINT AND WITH COMMON FILL WITHIN REMAINING
AREA AND COMPACTED AS NECESSARY.
CUT, REMOVE, AND DISPOSE OFF SITE 8" STORM PIPE SECTION.
VOID TO BE FILLED WITH STRUCTURAL FILL WITHIN PROPOSED
ADDITION FOOTPRINT AND WITH COMMON FILL WITHIN
REMAINING AREA AND COMPACTED AS NECESSARY.
CUT, REMOVE, AND DISPOSE OFF SITE 6" SANITARY PIPE
SECTION. PROTECT REMAINING PIPE SECTION FOR FUTURE
RECONNECTION. VOID TO BE FILLED WITH STRUCTURAL FILL
WITHIN PROPOSED ADDITION FOOTPRINT AND WITH COMMON
FILL WITHIN REMAINING AREA AND COMPACTED AS NECESSARY.
DISCONNECT EXISTING WATER SERVICE CONNECTION. THE
CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING
OFFICER'S REPRESENTATIVE FOR UTILITY DISCONNECTIONS
METHODS PRIOR TO START OF DEMOLITION. THE CONTRACTOR
IS RESPONSIBLE FOR OBTAINING ALL PERMITS FROM
AUTHORITIES HAVING JURISDICTION AND PAYMENT OF ALL FEES
PRIOR TO ANY WORK. VOID TO BE FILLED WITH STRUCTURAL FILL
WITHIN PROPOSED ADDITION FOOTPRINT AND WITH COMMON
FILL WITHIN REMAINING AREA AND COMPACTED AS NECESSARY.
DEMOLISH AND DISPOSE OFF SITE EXISTING SEWER M.H.
VOID TO BE FILLED WITH STRUCTURAL FILL AND
COMPACTED AS NECESSARY.
REMOVE AND DISPOSE OFF SITE 12" STORM PIPE SECTION. CAP
REMAINING PIPE SECTION AND PROTECT FOR FUTURE
RECONNECTION. VOID TO BE FILLED WITH STRUCTURAL FILL
WITHIN PROPOSED ADDITION FOOTPRINT AND WITH COMMON
FILL WITHIN REMAINING AREA AND COMPACTED AS NECESSARY.
REMOVE AND DISPOSE OFF SITE CATCH BASIN AND ALL
SUPPORTING STRUCTURES. VOID TO BE FILLED WITH
STRUCTURAL FILL AND COMPACTED AS NECESSARY.
REMOVE AND DISPOSE OFF SITE EXISTING LIGHTING FOUNDATION AND
ELECTRIC CONDUIT (TYPICAL FOR ALL LIGHTING FOUNDATION AND
ELECTRIC CONDUIT WITHIN THE HATCHED AREA). VOID TO BE FILLED WITH
STRUCTURAL FILL WITHIN PROPOSED ADDITION FOOTPRINT AND WITH
COMMON FILL WITHIN REMAINING AREA AND COMPACTED AS NECESSARY.
REMOVE AND SALVAGE ALL SITE FEATURE WITHIN THE
HATCHED AREA (STEEL BENCHES, STEEL LITTER
RECEPTACLE, FOOT (SPOT) LIGHTING, AND LIGHT BOLLARDS)
PROTECT EXISTING ROUND CATCH BASIN TO
REMAIN.
REMOVE AND DISPOSE OFF SITE EXISTING WATER VALVE. VOID
TO BE FILLED WITH STRUCTURAL FILL AND COMPACTED AS
NECESSARY.
"TOPOGRAPHIC MAP" OF PROPERTY LOCATED AT 555 WILLARD AVENUE,
NEWINGTON, CONNECTICUT; PREPARED FOR OFFICE OF CONSTRUCTION
AND FACILITIES MANAGEMENT, DEPARTMENT OF VETERANS AFFAIRS;
PROJECT TITLE: VA CONNECTICUT HEALTHCARE SYSTEM FACILITIES
MANAGEMENT SERVICE PLANAMETRIC DIGITAL BASE MAP. PREPARED BY
LEWIS ASSOCIATES; DATED: 07/11/2012; SCALE: 1"=20'. SHEET: 1 OF 3.
2016 LATEST REVIEW.
1. THE TERM DEMOLISH SHALL MEAN TO REMOVE ALL COMPONENTS OF THE NOTED ITEM AND TO DISPOSE OF THEM OFF SITE IN A
MANNER CONSISTENT WITH LOCAL, STATE AND FEDERAL REGULATIONS.
2. BURYING OF ANY DEBRIS ON SITE IS NOT PERMITTED
3. BURNING ON SITE IS NOT PERMITTED.
4. CONTRACTOR SHALL CALL "CALL BEFORE YOU DIG" 1.800.922.4455 FOR MARK OUT 72 HOURS PRIOR TO ANY SITE EXCAVATION.
5. ALL UTILITY DISCONNECTION OR REMOVALS SHALL BE COORDINATED WITH THE CONTRACTING OFFICER'S REPRESENTATIVE AND
APPROPRIATE UTILITY SERVICE PROVIDER.
6. CONTRACTOR IS REQUIRED TO DEMOLISH ALL FEATURES AS REQUIRED. THIS INCLUDES, BUT IS NOT LIMITED TO LANDSCAPING, CONCRETE SIDEWALKS, CONCRETE PADS, AND ABOVE GROUND STRUCTURES WHICH ARE WITHIN THE HATCHED AREA, UNLESS
SPECIFIED OTHERWISE.
7. ANY VOIDS REMAINING AFTER SITE DEMOLITION SHALL BE FILLED WITH STRUCTURAL FILL WITHIN PROPOSED ADDITION FOOTPRINT
AND WITH COMMON FILL WITHIN REMAINING AREA AND COMPACTED AS NECESSARY.
8. CONTRACTOR REQUIRED TO PERFORM EARTHWORK TO MEET ALL NEW GRADING REQUIRED WITHIN LIMIT OF WORK.
9. IT IS THE CONTRACTOR'S RESPONSIBILITY AND EXPENSE FOR PROTECTING THE ACCESS DRIVEWAY, GRANITE CURBS, EXISTING
RETAINING WALL, EXISTING CONCRETE STAIRS, AND PUBLIC ACCESS SIDEWALK FROM DAMAGE AS A DIRECT RESULT OF PROPOSED BUILDING ADDITION CONSTRUCTION ACTIVITY. ANY DAMAGES TO BE IMMEDIATELY REPORTED TO THE CONTRACTING OFFICER'S REPRESENTATIVE AND REPAIRED AS DIRECTED BY AND TO THE SATISFACTION OF THE VA OF NEWIGNTON OFFICIALS AT THE
CONTRACTOR'S EXPENSE. SEE SHEET CX103 FOR DETAILS.
10. ANY ABANDONED EXISTING UTILITY PIPES EXPOSED DURING CONSTRUCTION SHALL BE CUT AND REMOVED. THE REMAINDER OF THE PIPE SHALL BE PLUGGED AS NECESSARY, VOID TO BE FILLED WITH STRUCTURAL FILL WITHIN PROPOSED ADDITION FOOTPRINT AND
WITH COMMON FILL WITHIN REMAINING AREA AND COMPACTED AS NECESSARY
11. THE CONTRACTOR COORDINATE WITH THE CONTRACTING OFFICER'S REPRESENTATIVE FOR UTILITY DISCONNECTIONS PRIOR TO START OF DEMOLITION. EXISTING SANITARY SEWER LATERALS SERVING BUILDINGS THAT ARE BEING DEMOLISHED AND NOT APPROVED FOR REUSE SHALL BE DISCONNECTED OR PLUGGED. NEW LATERAL CONNECTIONS WILL NOT BE ACCEPTED UNTIL THE OLD LATERALS ARE PLUGGED AND PROPERLY ABANDONED. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS FROM AUTHORITIES HAVING JURISDICTION AND PAYMENT OF ALL FEES PRIOR TO ANY WORK. VOID TO BE FILLED WITH STRUCTURAL FILL WITHIN PROPOSED ADDITION FOOTPRINT AND WITH COMMON FILL WITHIN REMAINING AREA AND COMPACTED AS NECESSARY. (TYP.)
PROTECT EXISTING SANITARY SEWER PIPE TO REMAIN. PIPE NOT FIELD
SURVEY LOCATED. TAKEN FROM DRAWING PL101
SAW CUT CONCRETE WALK AT
THE CONCRETE STEP JOINT.
STEEL PIPE NOT FIELD SURVEY LOCATED, LOCATION IS
APPROXIMATE. CONTRACTOR TO FIELD INVESTIGATE STEEL PIPE
PURPOSE AND CONNECTIONS AND PRESENT FINDINGS TO THE
CONTRACTING OFFICER'S REPRESENTATIVE FOR FURTHER ACTION.
SAW CUT EDGES OF CONCRETE
WALK WHERE EXISTING MATERIAL
IS TO REMAIN.
REMOVE AND DISPOSE OFF SITE EXISTING STORM CLEANOUT.
VOID TO BE FILLED WITH STRUCTURAL FILL WITHIN PROPOSED
ADDITION FOOTPRINT AND WITH COMMON FILL WITHIN
REMAINING AREA AND COMPACTED AS NECESSARY.
(TYP. FOR ALL ON THE SITE STORM CLEANOUTS)
CUT, REMOVE, AND DISPOSE OFF SITE STORM PIPE SECTION. VOID TO BE FILLED WITH
SUITABLE FILL FOR INTENDED USE AND COMPACTED AS NECESSARY.
PROTECT EXISTING ROOF DRAIN LATERAL AT THE BUILDING, TO REMAIN. PIPE NOT FIELD
SURVEY LOCATED. TAKEN FROM DRAWING PL101
REMOVE AND DISPOSE OFF SITE STORM PIPE. VOID TO BE
FILLED WITH STRUCTURAL FILL AND COMPACTED AS
NECESSARY.
REMOVE AND DISPOSE OFF SITE STORM PIPE. VOID TO BE
FILLED WITH STRUCTURAL FILL AND COMPACTED AS
NECESSARY.
ELECTRIC LINE NOT FIELD SURVEY LOCATED, TAKEN FOR MAPPING AND LOCATION IS
APPROXIMATE. CONTRACTOR TO FIELD INVESTIGATE ELECTRIC LINE PURPOSE AND
CONNECTIONS AND PRESENT FINDINGS TO THE CONTRACTING OFFICER'S
REPRESENTATIVE FOR FURTHER ACTION.
IF FOUND TO BE ABANDONED, SEE SHEET EP101, NOTE 21.
CATCH BASIN
SANITARY LINE
STORM LINE
WATER LINE
WATER VALVE
UTILITY MANHOLE
SPOT GRADE
ELECTRIC LINE
ROOF LEADER
LIGHTING FIXTURE
YARD DRAIN
SANITARY CLEANOUT
LIGHT BOLLARD
STORM CLEANOUT
115.1
117.0117.0
117.0
115.1 115.1
117.3
114.9
115.2
117.0
114.8 114.9
114.8114.7 thr ee in ch es on e f oo t
6" on e a nd on e h alf in ch es on e f oo t 6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A R C H I T E C T S, I N C .
EXPAND PRIMARY CARE -
NEWINGTON VAMC
NEWINGTON, CT
689-402
JUNE 7, 2019 RL FV
1, 2, 3, 42
Department of Veterans Affairs
MARTINEZ COUCH & ASSOCIATES, LLC
SKILLED PROFESSIONALS.
PRACTICAL SOLUTIONS.
1084 Cromwell Avenue, Suite A-2 Rocky Hill, CT 06067 Tel: 860-436-4364
MartinezCouch.com
MCA Consulting Engineers & Surveyors DBE/MBE Certified
Site/Civil Engineering | Land Surveying | Energy & Sustainability Wastewater Engineering | Mechanical/Electrical/Plumbing | GIS
CG101
SITE GRADING AND
DRAINAGE PLAN
PROPOSED STM. CO.#1
TF=116.5'
INV.OUT=114.0'
PROPOSED 10± LF. - 12" HDPE PIPE.
@SLOPE=1.0%
PROPOSED 16± LF. - 12" HDPE
PIPE.
@SLOPE=1.9%
PROPOSED STM. CO.#4
TF=116.5'
INV.IN=114.0'(S)
INV.IN/OUT=113.6'
PROPOSED 38± LF. - 12" HDPE PIPE.
@0.5% MIN. SLOPE
PROPOSED STM. CO.#3
TF=116.5'
INV.IN/OUT=113.8'
PROPOSED 10± LF. - 12" HDPE PIPE.
@0.5% MIN. SLOPE
PROPOSED YARD DRAIN
TF=114.6'
INV.IN/OUT=112.6'
IT'S THE CONTRACTOR RESPONSIBILITY AND EXPENSE TO INVESTIGATE
EXISTING STORM DRAINAGE PIPE LOCATION AND ELEVATION PRIOR TO
ANY STORM WATER INSTALLATION. MATCH PROPOSED 12" HDPE PIPE
INVERTS ELEVATION WITH THE EXISTING 12". MIN. PIPE SLOPE=0.5% IF
THE MINIMUM SLOPE CAN NOT BE ACHIEVED, REPLACE ENTIRE EXISTING
12" PIPE SECTION BETWEEN PROPOSED YARD DRAIN AND EXISTING C.B.
#35 WITH NEW 12" HDPE PIPE AT MIN.S=0.5%
1. ALL AREAS ARE GRADED TO PROVIDE DRAINAGE AWAY FROM THE
PROPOSED ADDITION. PONDING ON ANY PAVEMENT SURFACES WILL BE
CAUSE FOR REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE.
2. ALL SLOPES ARE TO BE ADEQUATELY STABILIZED, BY METHODS DESCRIBED
ON SHEET CX101.
3. COMPACT FILL AS REQUIRED.
1. ALL PROPOSED STORM WATER PIPES TO BE HDPE ADS N-12 WITH SOIL TIGHT JOINTS OR
APPROVED EQUAL, UNLESS NOTED OTHERWISE ON THESE PLANS.
2. THE CONTRACTOR IS TO START ALL WORK AT THE LOWEST POINTS DOWNSTREAM AND WORK
UPSTREAM THROUGH THE SYSTEM. IT IS THE CONTRACTOR'S RESPONSIBILITY AND EXPENSE TO VERIFY IN THE FIELD THE INVERT ELEVATIONS OF EXISTING STORM STRUCTURES THAT PROPOSED
PIPE CONNECTIONS ARE TO BE MADE PRIOR TO STARTING ANY WORK.
3. REFER TO DRAWING SHEET CX102 FOR ALL PROPOSED STORM WATER STRUCTURE DETAILS AND
SECTIONS.
4. CLEAN ALL STRUCTURES INCLUDING SUMPS AND PIPES AT SUBSTANTIAL COMPLETION. STORM
PIPES AND STRUCTURES TO BE LEFT CLEAN AT COMPLETION OF CONSTRUCTION AT
CONTRACTOR'S EXPENSE. INDICATED UNDERGROUND UTILITIES ARE BASED ON INDICATED
MAP REFERENCES. THE LOCATIONS ARE TO BE CONSIDERED
APPROXIMATE AND ALL UTILITIES MAY NOT BE SHOWN. PRIOR
ANY CONSTRUCTION THE CONTRACTOR SHALL CALL
1-800-922-4455 AND HAVE ALL UTILITIES MARKED ON THE
GROUND.
PROPOSED STM. CO.#2
TF=116.5'
INV.IN/OUT=113.9'
CX102
CX102
PROPOSED ROOF LEADER
CONNECTION WITH BOOT
PROPOSED
BUILDING ADDITION
FF=117.68'
CONSTRUCTION LIMIT (TYP.)
ADJUST EXISTING ROUND CATCH BASIN GRATE. TO
MATCH PROPOSED GRADE IF REQUIRED ADD RISERS
OR REPLACE WITH NEW GRATE. MATCH DIAMETER AS
REQUIRED. PROPOSED 12" HDPE PIPE(S) TO CONNECT
INTO THE 6" OR 8" OPENING BY MEANS OF A
REDUCER. OPENING NOT TO BE ALTERED.
TF=115.75'
"TOPOGRAPHIC MAP" OF PROPERTY LOCATED AT 555 WILLARD AVENUE, NEWINGTON,
CONNECTICUT; PREPARED FOR OFFICE OF CONSTRUCTION AND FACILITIES MANAGEMENT,
DEPARTMENT OF VETERANS AFFAIRS; PROJECT TITLE: VA CONNECTICUT HEALTHCARE
SYSTEM FACILITIES MANAGEMENT SERVICE PLANAMETRIC DIGITAL BASE MAP. PREPARED BY
LEWIS ASSOCIATES; DATED: 07/11/2012; SCALE: 1"=20'. SHEET: 1 OF 3. 2016 LATEST REVIEW.
CX102
CX102
CX102
CX102
CX102
CX102
CX102
CX102
CX102
PROPOSED ROOF LEADER
CONNECTION WITH BOOT
CX102
PROPOSED ROOF LEADER
CONNECTION WITH BOOT
CX102
PROPOSED INTERNAL ROOF DISCHARGE.
SEE LATEST PLUMBING DRAWINGS
SHEET PL101.
PROPOSED 12± LF. - 12" HDPE PIPE.
@0.5% MIN. SLOPE
CX102
PROPOSED STM. CO.#5
TF=116.6'
INV.IN=MATCH EXISTING(E)
INV.IN/OUT=113.5'
CX102
PROPOSED 15± LF. - 12" HDPE PIPE.
@0.5% MIN. SLOPE. EXISTING PIPE
NOT FIELD LOCATED
CX102
CATCH BASIN
SANITARY LINE
STORM LINE
WATER LINE
WATER VALVE
UTILITY MANHOLE
SPOT GRADE
ELECTRIC LINE
ROOF LEADER
LIGHTING FIXTURE
YARD DRAIN
SANITARY CLEANOUT
LIGHT BOLLARD
STORM CLEANOUT
thr ee in ch es on e f oo t
6" on e a nd on e h alf in ch es on e f oo t 6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A R C H I T E C T S, I N C .
EXPAND PRIMARY CARE -
NEWINGTON VAMC
NEWINGTON, CT
689-402
JUNE 7, 2019 RL FV
1, 2, 3, 42
Department of Veterans Affairs
MARTINEZ COUCH & ASSOCIATES, LLC
SKILLED PROFESSIONALS.
PRACTICAL SOLUTIONS.
1084 Cromwell Avenue, Suite A-2 Rocky Hill, CT 06067 Tel: 860-436-4364
MartinezCouch.com
MCA Consulting Engineers & Surveyors DBE/MBE Certified
Site/Civil Engineering | Land Surveying | Energy & Sustainability Wastewater Engineering | Mechanical/Electrical/Plumbing | GIS
CU101
SITE UTILITIES PLAN
1. CONTRACTOR IS RESPONSIBLE TO VERIFY EXISTING UNDERGROUND UTILITIES LOCATIONS AND
ELEVATIONS WITHIN THE CONSTRUCTION AREA PRIOR TO CONSTRUCTION. ANY EXISTING
UNDERGROUND UTILITIES DISCOVERED DURING CONSTRUCTION THAT ARE IN CONFLICT WITH
THE PROPOSED UNDERGROUND UTILITIES ARE TO BE REPORTED TO THE CONTRACTING
OFFICER'S REPRESENTATIVE FOR FURTHER ACTION.
2. CONTRACTOR IS TO ENSURE CARE IS TAKEN TO PROTECT ANY UNDERGROUND UTILITIES. IF ANY UTILITIES BECOME DAMAGED AS A RESULT OF CONSTRUCTION ACTIVITIES, THE CONTRACTOR IS
RESPONSIBLE TO NOTIFY THE CONTRACTING OFFICER'S REPRESENTATIVE FOR IMMEDIATE
REPAIR AT THE CONTRACTOR'S EXPENSE
3. THE PROPOSED UTILITIES THAT ARE NOT DEPENDENT UPON GRAVITY FLOW MUST BE INSTALLED TO AVOID CONFLICT. EACH CONTRACTOR MUST COORDINATE WITH EACH UTILITY THAT HAS BEEN INSTALLED AND THE UTILITIES THAT REMAIN TO BE INSTALLED. THIS INCLUDES THE NEED TO DETERMINE THE VERTICAL AND HORIZONTAL LOCATION OF OTHER UTILITIES AND TO ANTICIPATE THE RECT LOCATION FOR ALL UNDERGROUND UTILITIES, PIPES, STRUCTURES, AND ANY OTHER
FEATURES, WHILE MAINTAINING MINIMUM REQUIRED COVER AND VERTICAL SEPARATION
DISTANCES. NOT ALL POTENTIAL CONFLICTS HAVE BEEN NOTED ON THE DRAWINGS.
4. REFER TO DRAWING SHEET CX102 FOR PROPOSED UNDERGROUND UTILITY DETAILS
1. ALL PROPOSED WATER SERVICE PIPE SHALL HAVE A MINIMUM 1.5 FT. VERTICAL
SEPARATION DISTANCE BETWEEN ALL UNDERGROUND UTILITIES. IF THIS CANNOT
ACHIEVED THE PIPE TO BE ENCASED IN CONCRETE.
2. IT IS THE CONTRACTOR'S RESPONSIBILITY AND EXPENSE TO PROVIDE THE NECESSARY
PROVISIONS REQUIRED TO ANY EXISTING UNDERGROUND UTILITIES TO CONSTRUCT
PROPOSED WATER SERVICE CONNECTION.
3. REFER TO DRAWING SHEETS CX102 FOR ALL PROPOSED WATER CONNECTION
DETAILS.
PROPOSED SAN. CO.#1
TF=116.7'
SEE LATEST PLUMBING
DRAWINGS SHEET PL101
PROPOSED 20± LF. - 3" INCH DIAMETER COPPER COLD
DRAWN OF SOFT ANNEALED SEAMLESS TYPE "K" (A.W.W.A.)
PIPE FOR DOMESTIC WATER SERVICE. MAINTAIN MINIMUM
4.5 FT. COVER OVER THE TOP OF THE PIPE. CONTRACTOR
SHALL MAINTAIN A MINIMUM VERTICAL CLEARANCE OF 18
INCHES BETWEEN SANITARY SEWER AND WATER PIPE,
MEASURED FROM CROWN TO INVERT. IF THIS CANNOT BE
ACHIEVED THE PIPE TO BE ENCASED IN CONCRETE.
INSTALL 10± L.F. - 6" PVC SCH.40 SANITARY SEWER
PIPE @ 1.1% MIN. SLOPE. MAINTAIN 4 FEET COVER
OVER THE PIPE. IT IS THE CONTRACTOR'S
RESPONSIBILITY AND EXPENSE TO FIELD VERIFY
INVERT ELEVATIONS.
PROPOSED SAN. CO.#2
TF=116.3'
INV.IN/OUT=111.3'
CX102
CX102
CX102
CX102
PROPOSED BUILDING
ADDITION
FF=117.68'
INDICATED UNDERGROUND UTILITIES ARE BASED ON INDICATED
MAP REFERENCES. THE LOCATIONS ARE TO BE CONSIDERED
APPROXIMATE AND ALL UTILITIES MAY NOT BE SHOWN. PRIOR
ANY CONSTRUCTION THE CONTRACTOR SHALL CALL
1-800-922-4455 AND HAVE ALL UTILITIES MARKED ON THE
GROUND.
CONSTRUCTION LIMIT (TYP.)
"TOPOGRAPHIC MAP" OF PROPERTY LOCATED AT 555 WILLARD AVENUE, NEWINGTON,
CONNECTICUT; PREPARED FOR OFFICE OF CONSTRUCTION AND FACILITIES MANAGEMENT,
DEPARTMENT OF VETERANS AFFAIRS; PROJECT TITLE: VA CONNECTICUT HEALTHCARE
SYSTEM FACILITIES MANAGEMENT SERVICE PLANAMETRIC DIGITAL BASE MAP. PREPARED BY
LEWIS ASSOCIATES; DATED: 07/11/2012; SCALE: 1"=20'. SHEET: 1 OF 3. 2016 LATEST REVIEW.
CATCH BASIN
SANITARY LINE
STORM LINE
WATER LINE
WATER VALVE
UTILITY MANHOLE
SPOT GRADE
ELECTRIC LINE
ROOF LEADER
LIGHTING FIXTURE
YARD DRAIN
SANITARY CLEANOUT
LIGHT BOLLARD
STORM CLEANOUT
CE 20'
9' thr ee in ch es on e f oo t
6" on e a nd on e h alf in ch es on e f oo t 6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A R C H I T E C T S, I N C .
EXPAND PRIMARY CARE -
NEWINGTON VAMC
NEWINGTON, CT
689-402
JUNE 7, 2019 RL FV
1, 2, 3, 42
Department of Veterans Affairs
MARTINEZ COUCH & ASSOCIATES, LLC
SKILLED PROFESSIONALS.
PRACTICAL SOLUTIONS.
1084 Cromwell Avenue, Suite A-2 Rocky Hill, CT 06067 Tel: 860-436-4364
MartinezCouch.com
MCA Consulting Engineers & Surveyors DBE/MBE Certified
Site/Civil Engineering | Land Surveying | Energy & Sustainability Wastewater Engineering | Mechanical/Electrical/Plumbing | GIS
CJ101
SOIL EROSION AND
SEDIMENT CONTROL PLAN
1. SOIL AND EROSION CONTROLS MEASURES SHOULD BE INSTALLED IN PLACE PRIOR TO ANY DEMOLITION OR EXCAVATION OF THE SUBJECT PROPERTY AND THE CONTRACTING OFFICER'S REPRESENTATIVE MUST BE CONTACTED TO INSPECT THE INSTALLATION PRIOR TO ANY FURTHER WORK ACTIVITY ONSITE.
2. ALL STORM DRAINAGE STRUCTURES SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REQUIRED REPAIRS TO THE SILT SOCKS SHALL BE
MADE IMMEDIATELY. THE SILT SOCK SHALL BE REPLACED PROMPTLY, SHOULD THE FABRIC
DECOMPOSE OR BECOME INEFFECTIVE PRIOR TO THE ESTABLISHMENT OF THE PERMANENT
VEGETATIVE COVER. SEDIMENT DEPOSITS SHOULD BE REMOVED WHEN THEY REACH APPROXIMATELY A ONE-HALF DEPTH OF THE SILTSACK. AT THE END OF THE CONSTRUCTION, WHEN THE SITE IS STABLE AND PERMANENT COVER OF ALL DISTURBED SURFACES IS COMPLETED, REMOVE THE SILTSACKS.
"TOPOGRAPHIC MAP" OF PROPERTY LOCATED AT 555 WILLARD AVENUE, NEWINGTON,
CONNECTICUT; PREPARED FOR OFFICE OF CONSTRUCTION AND FACILITIES
MANAGEMENT, DEPARTMENT OF VETERANS AFFAIRS; PROJECT TITLE: VA
CONNECTICUT HEALTHCARE SYSTEM FACILITIES MANAGEMENT SERVICE
PLANAMETRIC DIGITAL BASE MAP. PREPARED BY LEWIS ASSOCIATES; DATED:
07/11/2012; SCALE: 1"=20'. SHEET: 1 OF 3. 2016 LATEST REVIEW.
INSTALL SILTSACK UNDER
EXISTING CATCH BASIN
GRATE (TYP. OF 2)
CX101
INSTALL SILTSACK UNDER
PROPOSED YARD DRAIN GRATE
CX101
SILT BOOM (TYP.)3
CX101
INSTALL SILTSACK UNDER
EXISTING ROUND CATCH
BASIN GRATE (TYP.)
CX101
INSTALL 9' X 20'
CONSTRUCTION ENTRANCE
ANTI-TRACKING PAD
CX101
AREAS TO BE TOPSOILED
AND SEEDED.(TYP.)
AREAS TO BE
TOPSOILED AND
SEEDED (TYP)
GENERAL SOIL EROSION AND SEDIMENT CONTROL NOTES
(A) THE SOIL EROSION AND SEDIMENT CONTROL CONTACT PERSON: THE GENERAL CONTRACTOR HAS THE RESPONSIBILITY FOR IMPLEMENTING THE SOIL EROSION AND SEDIMENT CONTROL PLAN. THIS RESPONSIBILITY
INCLUDES:
- THE INSTALLATION AND MAINTENANCE OF THE REQUIRED CONTROL MEASURES
- INFORMING ALL PARTIES ENGAGED ON THE CONSTRUCTION SITE OF THE REQUIREMENTS AND OBJECTIVES OF
THE SOIL EROSION AND SEDIMENT CONTROL PLAN.
(A) ALL SOIL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE IN PLACE PRIOR TO ANY DEMOLITION AND/OR EXCAVATION ACTIVITY, INSTALLATION OF PROPOSED STRUCTURES OR UTILITIES. MEASURES SHALL BE LEFT IN PLACE
AND MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND/OR AREA IS STABILIZED.
(B) ENTRANCES TO THE PROJECT SITE ARE TO BE PROTECTED BY STONE TRACKING PADS OF ASTM C-33, SIZE NO. 2 OR 3, OR 2" CRUSHED GRAVEL. THE STONE TRACKING PAD IS TO BE MAINTAINED AT ALL TIMES DURING THE CONSTRUCTION
PERIOD.
(C) LAND DISTURBANCE WILL BE KEPT TO A MINIMUM AND RESTABILIZATION WILL BE SCHEDULED AS SOON AS
PRACTICAL.
(D) ALL SOIL EROSION AND SEDIMENT CONTROL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH PLANS AND
DETAILS.
(E) ANY ADDITIONAL EROSION/SEDIMENTATION CONTROL DEEMED NECESSARY BY CONTRACTING OFFICER REPRESENTATIVE DURING CONSTRUCTION, SHALL BE INSTALLED BY THE CONTRACTOR. IN ADDITION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR/REPLACEMENT/MAINTENANCE OF ALL EROSION CONTROL MEASURES UNTIL ALL DISTURBED AREAS ARE STABILIZED TO THE SATISFACTION OF THE CONTRACTING OFFICER.
(F) IN ALL AREAS, REMOVAL OF TREES, BUSHES AND OTHER VEGETATION AS WELL AS DISTURBANCE OF THE SOIL IS TO BE KEPT TO AN ABSOLUTE MINIMUM WHILE ALLOWING PROPER DEVELOPMENT OF THE SITE. DURING CONSTRUCTION, EXPOSE AS SMALL AN AREA OF SOIL AS POSSIBLE FOR AS SHORT A TIME AS POSSIBLE.
(G) SILT BOOM SHALL BE PLACED AS INDICATED. SEDIMENT DEPOSITS SHOULD BE PERIODICALLY REMOVED FROM THE UPSTREAM SIDES OF SILT BOOM. SILT BOOM ARE TO BE REPLACED AS NECESSARY TO PROVIDE PROPER FILTERING ACTION. SILT BOOM ARE TO REMAIN IN PLACE AND BE MAINTAINED TO INSURE EFFICIENT SILTATION CONTROL UNTIL
COMPLETION ALL CONSTRUCTION WORKS.
(H) INLETS SHALL BE PROTECTED WITH SILTSOCKS THROUGHOUT CONSTRUCTION AND UNTIL ALL DISTURBED AREAS ARE THOROUGHLY STABILIZED. ALL STORM DRAINAGE STRUCTURES SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REQUIRED REPAIRS TO THE SILTSOCKS SHALL BE MADE IMMEDIATELY. THE SILTSOCKS SHALL BE REPLACED PROMPTLY, SHOULD THE FABRIC DECOMPOSE OR BECOME INEFFECTIVE PRIOR TO THE ESTABLISHMENT OF THE PERMANENT VEGETATIVE COVER. SEDIMENT DEPOSITS SHOULD BE REMOVED WHEN THEY REACH APPROXIMATELY A ONE-HALF DEPTH OF THE SILTSOCK. AT THE END OF THE CONSTRUCTION, WHEN THE SITE IS STABLE AND PERMANENT COVER OF ALL DISTURBED SURFACES IS COMPLETED, REMOVE THE SILTSOCKS.
(I) ALL FILL AREAS SHALL BE COMPACTED SUFFICIENTLY FOR THEIR INTENDED PURPOSE AND AS REQUIRED TO REDUCE
SLIPPING, EROSION OR EXCESS SATURATION.
(J) TOPSOIL SHALL NOT BE PLACED WHILE IN A FROZEN OR MUDDY CONDITION, WHEN THE SUBGRADE IS EXCESSIVELY WET, OR IN A CONDITION THAT MAY OTHERWISE BE DETRIMENTAL TO PROPER GRADING OR PROPOSED SODDING OR
SEEDING.
TEMPORARY VEGETATIVE COVER (TV):
TEMPORARY VEGETATIVE COVER SHALL BE ESTABLISHED ON ALL SOILS EXPOSED FOR PERIODS OF UP TO 3 MONTHS.
1. SITE PREPARATION:
(A) GRADE AREA AS NEEDED AND FEASIBLE TO PERMIT THE USE OF EQUIPMENT FOR SEEDBED PREPARATION, SEEDING, MULCH APPLICATION AND MULCH ANCHORING. ALL GRADING SHOULD BE DONE IN ACCORDANCE WITH THE PLANS
AND DETAILS.
(B) INSTALL NEEDED EROSION CONTROL MEASURES SUCH AS GRADE STABILIZATION STRUCTURES AND SEDIMENT
BASINS.
2. SEEDBED PREPARATION
(A) APPLY LIMESTONE AND FERTILIZER ACCORDING TO SOIL TEST RECOMMENDATIONS SUCH AS THOSE OFFERED BY THE UNIVERSITY OF CT SOIL TESTING LABORATORY. SOIL SAMPLE MAILERS ARE AVAILABLE FROM THE LOCAL COOPERATIVE EXTENSION SERVICE OFFICE. IF SOIL TESTING IS NOT FEASIBLE ON SMALL OR VARIABLE SITES, OR WHERE TIMING IS CRITICAL, FERTILIZER MAY BE APPLIED AT THE RATE OF 300 LBS. PER ACRE OR 7.5 LBS PER 1,000 SQ.FT. OF 10-10-10 OR EQUIVALENT. APPLY LIMESTONE (EQUIVALENT TO 50 PERCENT CALCIUM PLUS MAGNESIUM
OXIDE) AS FOLLOWS:
SOIL TEXTURE TONS/ACRE LBS/1,000 SQ.FT.
CLAY, CLAY LOAM AND HIGH ORGANIC SOIL 3 135
SANDY LOAM, LOAM, SILT LOAM 2 90
LOAMY SAND, SAND 1 45
REFER TO HARTFORD COUNTY SOIL SURVEY REPORT FOR SOIL TEXTURES AT THE SITE.
(B) WHERE THE SOIL HAS BEEN COMPACTED BY CONSTRUCTION OPERATIONS, LOOSEN SOIL TO DEPTH OF 4 INCHES
BEFORE APPLYING FERTILIZER LIME AND SEED.
(C) APPLY SEED UNIFORMLY BY HAND, CYCLONE SEEDER, DRILL, CULTIPACKER TYPE SEEDER OR HYDROSEEDER (SLURRY INCLUDING SEED AND FERTILIZER). HYDROSEEDINGS, WHICH INCLUDE MULCH, MAY BE LEFT ON SOIL
SURFACE. SEEDING RATES MUST BE INCREASED 10% WHEN HYDROSEEDING.
3. MULCHING
(A) SEE GUIDELINES IN TEMPORARY MULCHING (MU) SECTION
PERMANENT VEGETATIVE COVER (PV):
PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED ON ALL EXPOSED SOILS WHERE PERENNIAL VEGETATION IS
NEEDED FOR LONG TERM PROTECTION.
1. SITE PREPARATION: SEE SPECIFICATION 31 20 11
2. SEEDBED PREPARATION: SEE SPECIFICATION 31 20 11
3. SEEDING DATES
(A) SPRING SEEDINGS USUALLY GIVE THE BEST RESULTS. SPRING SEEDINGS OF ALL SEED MIXES WITH LEGUMES IS RECOMMENDED, HOWEVER LATE SUMMER SEEDINGS PRIOR TO SEPTEMBER 1 CAN BE MADE. WHEN CROWN VETCH IS SEEDED IN LATE SUMMER AT LEAST 35 PERCENT OF THE SEED SHOULD BE HARD SEED (UNSCARIFIED). THE
RECOMMENDED SEEDING DATES ARE:
APRIL 15 THROUGH JUNE 15
AUGUST 15 THROUGH SEPTEMBER 1
4. SEEDING: SEE SPECIFICATION 31 20 11
MAINTENANCE
(D) LIME ACCORDING TO A SOIL TEST OR AT A MINIMUM OF EVERY FIVE YEARS USING A RATE OF TWO TONS PER ACRE
(100 POUNDS PER 1,000 SQUARE FEET).
(E) WHERE GRASSES PREDOMINATE, FERTILIZE ACCORDING TO A SOIL TEST OR BROADCAST BIENNIALLY, 300 POUNDS
OF 10-10-10 OR EQUIVALENT PER ACRE (7.5 POUNDS PER 1,000 SQUARE FEET).
(F) WHERE LEGUMES PREDOMINATE, FERTILIZE ACCORDING TO A SOIL TEST OR BROADCAST EVERY THREE YEARS 300 POUNDS OF 0-20-20 OR EQUIVALENT PER ACRE (7.5 POUNDS PER 1,000 SQUARE FEET). SILT FENCES - INSTALLATION
REQUIREMENTS
5. SHEET FLOW APPLICATIONS ONLY
(A) SILTBOOM SHALL BE INSTALLED ACCORDING TO THE MANUFACTURE OR SUPPLIER.
(B) THE SILTBOOM SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFUL PURPOSE, BUT NOT BEFORE THE
UPSLOPE AREA HAS BEEN PERMANENTLY STABILIZED.
6. MAINTENANCE
(A) SILTBOOM SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED
RAINFALL. ANY REQUIRED REPAIRS SHALL BE MADE IMMEDIATELY.
(B) THE SILTBOOM SHALL BE REPLACED PROMPTLY, SHOULD THE FABRIC DECOMPOSE OR BECOME INEFFECTIVE PRIOR
TO THE ESTABLISHMENT OF PERMANENT VEGETATIVE COVER.
(C) SEDIMENT DEPOSITS SHOULD BE REMOVED WHEN THEY REACH APPROXIMATELY ONE-HALF THE HEIGHT OF THE
BARRIER.
(D) ANY SEDIMENT DEPOSIT REMAINING IN PLACE AFTER THE SILT BOOM IS NO LONGER REQUIRED SHALL BE DRESSED
TO CONFORM TO THE EXISTING GRADE PREPARED AND SEEDED.
TEMPORARY MULCHING (MU)
DEFINITION APPLICATION OF PLANT RESIDUES OR OTHER SUITABLE MATERIALS TO THE SOIL
SURFACE.
1. INSTALLATION REQUIREMENTS
(A) AREAS WHICH HAVE BEEN TEMPORARILY OR PERMANENTLY SEEDED SHALL BE MULCHED
IMMEDIATELY FOLLOWING SEEDING. MULCH ANCHORING WILL BE USED ON SLOPES GREATER
THAN 3 PERCENT. AREAS WHICH CANNOT BE SEEDED WITHIN THE SEEDLING DATES SHOULD BE
MULCHED TO PROVIDE TEMPORARY PROTECTION TO THE SOIL SURFACE. AN ORGANIC MULCH
OTHER THAN WOOD FIBER ALONE SHALL BE USED, AND THE AREA SHALL BE SEEDED AS SOON
AS SEEDING DATES PERMIT. MULCH SHALL BE USED WHEN TREE, SHRUB, AND GROUND COVER
PLANTINGS DO NOT PROVIDE ADEQUATE EROSION PROTECTION.
2. ORGANIC MULCHES
(A) ORGANIC MULCHES MAY BE USED IN ANY AREA WHERE MULCH IS REQUIRED, SUBJECT TO THE
RESTRICTIONS NOTED IN THE STATE OF CT "GUIDELINES FOR SOIL EROSION & SEDIMENT
CONTROL". STRAW OR HAY MULCH MUST BE ANCHORED IMMEDIATELY AFTER SPREADING TO
PREVENT WIND BLOWNING. OTHER ORGANIC MULCHES DO NOT REQUIRE ANCHORING. THE
FOLLOWING METHODS OF ANCHORING STRAW OR HAY MAY BE USED.
(B) MULCH ANCHORING TOOL THIS IS A TRACTOR-DRAWN IMPLEMENT DESIGNED TO PUNCH
MULCH INTO THE SOIL SURFACE. THIS METHOD PROVIDES MAXIMUM EROSION CONTROL WITH
STRAW. IT IS LIMITED TO USE ON SLOPES NO STEEPER THAN 3 TO 1 (3 HORIZONTALLY TO 1
VERTICALLY), WHERE EQUIPMENT CAN OPERATE SAFELY. MACHINERY SHALL BE OPERATED ON
THE CONTOUR.
(C) TRACKING APPLY MULCH AND DRIVE TRACKED EQUIPMENT UP AND DOWN SLOPE OVER ENTIRE
SURFACE SO CLEAT MARKS ARE PARALLEL TO CONTOUR.
(D) LIQUID MULCH BINDERS APPLICATION OF LIQUID MULCH BINDERS AND TACKIFIERS SHOULD BE
HEAVIEST AT EDGES OF AREAS AND AT CRESTS OF RIDGES AND BANKS TO PREVENT WIND
BLOWING. THE REMAINDER OF THE AREA SHOULD HAVE BINDER APPLIED UNIFORMLY. BINDERS
MAY BE APPLIED AFTER MULCH IS SPREAD OR MAY BE SPRAYED INTO THE MULCH AS IT IS BEING
BLOWN ONTO THE SOIL. APPLYING STRAW AND BINDER TOGETHER IS THE MOST EFFECTIVE
METHOD. THE FOLLOWING TYPES OF BINDERS MAY BE USED:
SYNTHETIC BINDERS
CHEMICAL BINDERS SUCH AS PETROSET, TERRATACK, HYDRO MULCH, AND AEROSPRAY MAY BE USED AS RECOMMENDED BY THE MANUFACTURER TO ANCHOR MULCH. THEY ARE USEFUL IN RESIDENTIAL
AREAS WHERE ASPHALT MAY BE A PROBLEM.
(A) MULCH NETTINGS INSTALL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
(B) PEG AND TWINE DRIVE 4-INCH TO 6-INCH WOODEN PEGS TO WITHIN 3 INCHES OF THE SOIL SURFACE EVERY 3 FEET IN ALL DIRECTIONS. STAKES MAY BE DRIVEN BEFORE OR AFTER STRAW
IS SPREAD. SECURE MULCH BY STRETCHING TWINE BETWEEN PEGS IN A
CRISS-CROSS-WITHIN-A-SQUARE PATTERN. TURN TWINE 2 OR MORE TIMES AROUND EACH PEG.
3. CHEMICAL MULCHES
(A) CHEMICAL MULCHES MAY BE USED ALONE IN THE FOLLOWING SITUATIONS: FROM MAY 1 TO JUNE 15 AND SEPTEMBER 15 TO OCTOBER 15, PROVIDED THAT THEY ARE USED ON AREAS WITH
SLOPES NO STEEPER THAN 4 TO 1 (4 HORIZONTALLY TO 1 VERTICALLY), WHICH HAVE BEEN
ROUGHENED. IF EROSION STILL OCCURS, ANOTHER MULCH MATERIAL SHALL BE APPLIED
IMMEDIATELY.
NOTE: CHEMICAL MULCHES MAY BE USED TO BIND OTHER MULCHES OR WITH WOOD FIBER IN A
HYDROSEEDED SLURRY AT ANY TIME. MANUFACTURER'S RECOMMENDATIONS FOR APPLICATION
OF CHEMICAL MULCHES SHALL BE FOLLOWED.
4. MATS
(A) INSTALL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS
MAINTENANCE
ALL MULCHES MUST BE INSPECTED PERIODICALLY, IN PARTICULAR AFTER RAINSTORMS, TO CHECK FOR SOIL EROSION. WHERE EROSION IS OBSERVED, ADDITIONAL MULCH SHOULD BE APPLIED. NET SHOULD BE INSPECTED AFTER RAINSTORMS FOR DISLOCATION OR FAILURE. IF WASHOUTS OR BREAKAGE OCCUR, RE-INSTALL NET AS NECESSARY AFTER REPAIRING DAMAGE TO THE INSPECTIONS SHOULD TAKE PLACE UNTIL GRASSES ARE FIRMLY ESTABLISHED. GRASSES SHALL NOT BE CONSIDERED ESTABLISHED UNTIL A GROUND COVER IS ACHIEVED WHICH IS MATURE ENOUGH TO CONTROL SOIL EROSION AND TO SURVIVE SEVERE WEATHER CONDITIONS. WHERE MULCH IS USED IN CONJUNCTION WITH ORNAMENTAL PLANTINGS, INSPECT PERIODICALLY THROUGHOUT THE YEAR TO DETERMINE IF MULCH IS MAINTAINING
COVERAGE OF THE SOIL SURFACE; REPAIR AS NEEDED.
5. DUST CONTROL MEASUREMENT AND RECOMMENDATIONS
CONSTRUCTION ACTIVITIES AT THE PROJECT SITE WILL RESULT IN EMISSIONS OF FUGITIVE DUST TO THE ATMOSPHERE. THE QUANTITY OF FUGITIVE DUST GENERATED WILL BE CONTROLLED BUT IS DEPENDENT UPON WEATHER CONDITIONS. FUGITIVE DUST PARTICLES HAVE A GREATER PROPENSITY TO BECOME AIRBORNE DURING DRY AND BREEZY METEOROLOGICAL CONDITIONS. CONSTRUCTION ACTIVITIES AT THE SITE WHICH WILL RESULT IN THE GENERATION OF FUGITIVE DUST INCLUDE GRADING, MATERIAL LOADING AND UNLOADING, MATERIAL STORAGE PILES AND CONSTRUCTION TRAFFIC. THE CONTRACTOR WILL IMPLEMENT THE FOLLOWING REASONABLE PRECAUTIONS DURING CONSTRUCTION TO MINIMIZE
THE GENERATION OF FUGITIVE DUST:
(A) USE WATER FOR DUST CONTROL OF ACTIVE CONSTRUCTION AREAS, ACTIVE UNPAVED ROADS, AND OTHER SURFACES WHICH CAN GIVE RISE TO AIRBORNE A TYPICAL PRACTICE TO BE
FOLLOWED DURING SITE GRADING WILL BE TO FOLLOW THE EARTH MOVING EQUIPMENT WITH A
WATER TRUCK TO IMMEDIATELY WET THE NEWLY DISTURBED AREA.
(B) APPLY THE BINDER COURSE OF PAVING MATERIAL TO SITE AS SOON AS FEASIBLE DURING
CONSTRUCTION.
(C) THE CONTRACTOR MUST CLEAN/SWEEP DAILY ALL ON-SITE PAVED ROADS AND THAT PORTION
OF THE EXISTING PAVED SURFACES ON AND OFFSITE THAT ARE USED FOR THE DURATION OF
THE PROJECT BY CONSTRUCTION TRAFFIC. INSTITUTE A MAXIMUM ON SITE SPEED LIMIT OF 15
MILES PER HOUR.
(D) THE CONTRACTOR IS RESPONSIBLE FOR DUST CONTROL DURING THE CONSTRUCTION
PROCESS. THE CONTRACTOR SHALL INSPECT THE SITE TO ASSURE DUST IS ADEQUATELY
CONTROLLED. IF THE OWNERS REPRESENTATIVE DETERMINES DUST CONTROL MEASURES ARE
NOT ADEQUATE THE CONTRACTOR SHALL BE REQUIRED TO INCREASE THESE MEASURES AS
DIRECTED.
'SILT SACK' SEDIMENT CONTROL
DEVICE USE 1 14" SIZE CLEAN STONE
CHECK DAMS TO DIRECT WATER
INTO STRUCTURE
NOTE:
1.) IN UNPAVED AREAS, USE STONE CHECK DAMS TO GUIDE RUNOFF
INTO CATCH BASIN
2.) SILT SOCK TO REMAIN UNTIL DISTURBED AREAS ARE
COMPLETELY STABILIZED.
SUBBASE, WHERE REQUIRED
'CL' CATCH BASIN STRUCTURE
EXPANSION RESTRAINT
6 INCH.
SEE PLAN
PAVED ROADWAY
SEE PLAN
NTS
NTS
1.5" X 1.5" X 36" WOODEN
STAKES PLACED 10' O.C.
12" MIN
SILT BOOMBLOWN/PLACED FILTER
MEDIA™
AREA TO BE PROTECTED
WORK AREA
WORK AREA
AREA TO BE PROTECTED
1.5" X 1.5" X 36" WOODEN
STAKES PLACED 10' O.C.
SILT BOOM
WATER FLOW
PLAN VIEWSECTION
NTS
SEPARATION GEOTEXTILE
FILTER FABRIC TC MIRATI
140N OR APPROVED EQUAL
3/4" CLEAN CRUSHED STONE
thr ee in ch es on e f oo t
6" on e a nd on e h alf in ch es on e f oo t 6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A R C H I T E C T S, I N C .
EXPAND PRIMARY CARE -
NEWINGTON VAMC
NEWINGTON, CT
689-402
JUNE 7, 2019 RL FV
1, 2, 3, 42
Department of Veterans Affairs
MARTINEZ COUCH & ASSOCIATES, LLC
SKILLED PROFESSIONALS.
PRACTICAL SOLUTIONS.
1084 Cromwell Avenue, Suite A-2 Rocky Hill, CT 06067 Tel: 860-436-4364
MartinezCouch.com
MCA Consulting Engineers & Surveyors DBE/MBE Certified
Site/Civil Engineering | Land Surveying | Energy & Sustainability Wastewater Engineering | Mechanical/Electrical/Plumbing | GIS
CX101
EROSION & SEDIMENTATION
CONTROL NOTES AND DETAILS
2" (MIN.) CRUSHED STONE
thr ee in ch es on e f oo t
6" on e a nd on e h alf in ch es on e f oo t 6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A R C H I T E C T S, I N C .
EXPAND PRIMARY CARE -
NEWINGTON VAMC
NEWINGTON, CT
689-402
JUNE 7, 2019 RL FV
1, 2, 3, 42
Department of Veterans Affairs
MARTINEZ COUCH & ASSOCIATES, LLC
SKILLED PROFESSIONALS.
PRACTICAL SOLUTIONS.
1084 Cromwell Avenue, Suite A-2 Rocky Hill, CT 06067 Tel: 860-436-4364
MartinezCouch.com
MCA Consulting Engineers & Surveyors DBE/MBE Certified
Site/Civil Engineering | Land Surveying | Energy & Sustainability Wastewater Engineering | Mechanical/Electrical/Plumbing | GIS
CX102
DETAILS
PAVING AS REQUIRED
WARNING TAPE
2'-0" MIN.
(OVER PIPE)
WATER SERVICE
PIPE DIAMETER
MIN. MIN.
UTILITY WARNING TAPE TO
BE METALIZED PLASTIC,
BLUE IN COLOR, MINIMUM
3" MINIMUM (WIDE) WITH
"CAUTION- WATER LINE
BURIED BELOW"
IMPRINTED IN BLACK
LETTERS
SAND COMPACTED IN 12" LAYERS TO 2'
ABOVE TOP OF THE PIPE
4'
- 6
" M
IN
. C O
V E
R
- D
O M
E S
TI
C
W A
TE
R
S E
R V
IC
E
1'-6" 1'-6"
WATER SERVICE
PIPESECTION
4" FOR 12"-24" PIPE
6" FOR 30"-60" PIPE
6"
MIN. COVER TO
RIGID PAVEMENT, H
MIN. COVER TO
FLEXIBLE PAVEMENT, H
SPRINGLINE
12" 30"
PIPE DIAM. MIN. TRENCH WIDTH
RECOMMENDED MINIMUM TRENCH WIDTHS
INITIAL
BACKFILL(CLASS I)
CLASS I MATERIAL TO
SPRINGLINE OF PIPE
BEDDING 34" CLEAN
CRUSHED STONE
SUITABLE
FOUNDATION
12"12" - 48"
PIPE DIAM.
SURFACE LIVE LOADING CONDITION
MINIMUM RECOMMENDED COVER BASED ON
VEHICLE LOADING CONDITIONS
H-20
NOTES:
1. ALL PIPE SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ASTM D2321, "STANDARD PRACTICE FOR UNDERGROUND INSTALLATION OF THERMOPLASTIC
PIPE FOR SEWERS AND OTHER GRAVITY FLOW APPLICATIONS", LATEST ADDITION
2. MEASURES SHOULD BE TAKEN TO PREVENT MIGRATION OF NATIVE FINES INTO BACKFILL MATERIAL, WHEN REQUIRED.
3. FOUNDATION: WHERE THE TRENCH BOTTOM IS UNSTABLE, THE CONTRACTOR SHALL EXCAVATE TO A DEPTH REQUIRED BY THE CONTRACTOR OFFICER AND REPLACE WITH SUITABLE MATERIAL AS SPECIFIED BY CONTRACTOR OFFICER. AS AN ALTERNATIVE AND AT THE DISCRETION OF THE CONTRACTOR OFFICER
REPRESENTATIVE. THE TRENCH BOTTOM MAY BE STABILIZED USING A GEOTEXTILE MATERIAL.
4. BEDDING: SUITABLE MATERIAL SHALL BE 34" CLEAN CRUSHED STONE. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. UNLESS OTHERWISE NOTED BY THE CONTRACTOR OFFICER, MINIMUM BEDDING THICKNESS SHALL BE 4" FOR 4"-24"; 6" FOR 30"-60".
5. INITIAL BACKFILL: SUITABLE MATERIAL SHALL BE CLASS I IN THE PIPE ZONE EXTENDING NOT LESS THAN 6" ABOVE CROWN OF PIPE. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. MATERIAL SHALL BE INSTALLED AS REQUIRED IN ASTM D2321, LATEST EDITION.
6. MINIMUM COVER: MINIMUM COVER, H, IN NON-TRAFFIC APPLICATIONS (GRASS OR LANDSCAPE AREAS) IS 12" FROM THE TOP OF PIPE TO GROUND SURFACE.
ADDITIONAL COVER MAY BE REQUIRED TO PREVENT FLOTATION. FOR TRAFFIC APPLICATIONS, MINIMUM COVER, H, IS 12" UP TO 48" DIAMETER PIPE AND 24" OF COVER FOR 54"-60" DIAMETER PIPE, MEASURED FROM TOP OF PIPE TO BOTTOM OF FLEXIBLE PAVEMENT OR TO TOP OF RIGID PAVEMENT.
MIN. TRENCH WIDTH
(SEE TABLE)
FLOOR BOX FRAME AND LID, W/S.S.
CAP SCREW LID CLOSURE. SUITABLE
FOR HS-20 LOADING
CLASS "F" CONCRETE
4,500 PSI
CLEAN-OUT W/ SCREW-IN PLUG
SCH.40 PVC PIPE AND FITTINGS.
(TYP.)
45° ELBOWWYE
45° ELBOW
FINISHED GRADE
CONC. 24" SQUARE
10 12"
9"
4"
10"
6"
2"
THE BACKFILL MATERIAL SHALL BE CRUSHED STONE
OR OTHER GRANULAR MATERIAL MEETING THE
REQUIREMENTS OF CLASS II MATERIAL AS DEFINED IN
ASTM D2321. BEDDING & BACKFILL FOR SURFACE
DRAINAGE INLETS SHALL BE PLACED & COMPACTED
UNIFORMLY IN ACCORDANCE WITH ASTM D2321.
8" MINIMUM
6" MINIMUM- EARTH
12" MINIMUM- ROCK
S E
E P
LA
N
GRAY IRON FRAME AND GRATE SHALL MEET
HS-20 LOAD RATING REQUIREMENTS IN
TRAFFIC AREAS
COMPACTED/
UNDISTURBED EARTH
SECTION
FRAME AND GRATE
IN
LE
T
IN
C
H H
D P
E
24"
YARD DRAIN
UNIT
3" 1-1/2"
NYLOPLAST
DUCTILE IRON
DO
N
OT
P
OL
LU
TE
D
RA
IN
S
TO
W
AT
ER
W
AY
S
1-1/4"
28-1/2"
24-3/4"
2' MINIMUM
SUMP
O U
TL
E
T
IN
C
H
VARIES
SEE PLANS
1. COVER SHALL BE GRAY IRON CASTING PER ASTM A-48-86 CLASS 30B.
2. FRAMES SHALL BE GRAY IRON.
3. DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR
CORRUGATED HDPE PIPES
4. ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°
5. FRAME AND COVER SHALL MEET HS-20 LOAD RATING REQUIREMENT FOR TRAFFIC
AREAS.
24" DIAMETER GRAY IRON FRAME SOLID COVER, SEE
NOTE 1 AND 2
18" MIN.
8"
MIN.
12" HDPE CONTRACTING
CORRUGATED PIPE
SOIL TIGHT JOINT. SEE NOTE 4 BEDDING MATERIAL SHALL BE 6" THICK- 34" CLEAN
CRUSHED STONE
BACKFILL MATERIAL SHALL BE CRUSHED STONE OR
GRANULAR MATERIAL MEETING THE REQUIREMENTS
OF CLASS II MATERIAL AS DEFINED IN ASTM D2321.
BEDDING AND BACKFILL FOR SURFACE DRAINAGE
INLETS SHALL BE PLACED AND COMPACTED
UNIFORMLY IN ACCORDANCE WITH ASTM D2321
UNDISTURBED/ COMPACTED
EARTH
CONCRETE COLLAR
CLASS "F" 4,500 PSI
RISER HEIGHT
VARIES
NO
SUMP
REQUIRED
24 INCH DIAMETER PVC
JUNCTION UNIT
16"
28"
FRONT VIEW
4 14"
3 14"
TOP VIEW
ISOMETRIC VIEW
2"
Ø47 8"
SIDE VIEW TYPICAL MOUNTING DETAIL
CUSTOMIZABLE
FRONT PANEL
4"
INSIDE BODY:
3" X 4"
STAINLESS STEEL
TAMPER-PROOF
SCREW(2)
2 5
16" X 4" CLEANOUT
WITH NEOPRENE
GASKET
SHOWN WITH
RUBBER ADAPTOR
CONNECTION
DOWNSPOUT
BOOT
DOWNSPOUT
2.
FT
M
IN
CONCRETE COLLAR
CLASS "F" 4,500 PSI
NOTES:
1. ALL EXCAVATED MATERIAL SHALL BE REMOVED FROM THE SITE AND
DISPOSED.
2. BACKFILL MATERIAL SHALL BE APPROVED BACKFILL ASTM D2321 CLASS III
IN PAVED AREAS (INCLUDING DRIVEWAYS AND SIDEWALKS) OR COMMON
FILL IN UNPAVED AREAS.
3. TRENCH WIDTH VARIES BASED ON PIPE SIZE AND DEPTH.TRENCHES
LOCATED IN THE ROAD SHOULDER SHALL BE TREATED THE SAME AS
TRENCHES IN THE PAVED ROADWAY EXCEPT FOR PAVEMENT AND
SURFACE RESTORATION WORK.
4. PROVIDE IMPERVIOUS TRENCH DAM(S) IN BEDDING IF DIRECTED BY THE
CONTRACTING OFFICER'S REPRESENTATIVE.
5. EXCAVATION TRENCH SHALL BE CONFORM TO SPECIFICATIONS
6. PVC SHALL BE INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS.
6" LOAM, FERTILIZE & SEED W/
GRASS, MULCH OR SOD
EXISTING GRASS AREA
UNDISTURBED MATERIAL
COMMON FILL SEE NOTES 1
AND 2
3" MINIMUM WIDE UNDERGROUND
WARNING TAPE (DETECTABLE)
GEOTEXTILE FABRIC WRAPPED
AROUND BEDDING W/ 12" MIN.
OVERLAP IN ALL DIRECTIONS
24"
SEWER PIPE
6" MIN. IN EARTH, 12" MIN. IN ROCK
PAVED UNPAVED
REFER TO PAVEMENT
RESTORATION DETAILS
EXISTING PAVEMENT
PROCESSED AGGREGATE BASE
BACKFILL ASTM D2321 CLASS III.
SEE NOTES 1 AND 2
SAND PLACED IN 12" LAYERS
CRUSHED STONE TO SPRINGLINE
OR TOP OF PIPE SEE NOTE 5
UNDISTURBED OR SUITABLE
COMPACTED MATERIAL
TRENCH WIDTH
VARIES SEE NOTE 3
12"
MIN
O.D. 12"
MIN
O.D.
BEDDING AND BACKFILL ASTM D2321
CLASS III.
IN PAVED
BACKFILL MATERIAL SHALL BE
GRANULAR FILL
IN GRASS
COMMON FILL
IN GRASSIN PAVED
18" 18"
13 3 4"
THE BEDDING MATERIAL SHALL BE 6
INCHES THICK OF 34" CLEAN CRUSHED
STONE
NOTE:
1. COVER MEETS H-20 LOAD RATING. COVER SHALL BE GRAY IRON CASTING PER ASTM
A-48-83 CLASS 30B.
2. CASTINGS ARE FURNISHED WITH A BLACK PAINT
3. LOCKING DEVICE AVAILABLE UPON REQUEST
4. APPROXIMATE WEIGHT WITH FRAME = 138 LBS
5. NYLOPLAST: 24"- 2499CGS OR APPROVED EQUAL
28-1/2"
24-3/4"
3" 1-1/2"
GREY IRON FRAMEGREY IRON COVER
FRAME AND SOLID COVER
COMMON FILL
BACKFILL ASTM D2321 CLASS III.
thr ee in ch es on e f oo t
6" on e a nd on e h alf in ch es on e f oo t 6" on e i nc h = on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f oo t
6"
6"
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A R C H I T E C T S, I N C .
EXPAND PRIMARY CARE -
NEWINGTON VAMC
NEWINGTON, CT
689-402
JUNE 7, 2019 RL FV
1, 2, 3, 42
Department of Veterans Affairs
MARTINEZ COUCH & ASSOCIATES, LLC
SKILLED PROFESSIONALS.
PRACTICAL SOLUTIONS.
1084 Cromwell Avenue, Suite A-2 Rocky Hill, CT 06067 Tel: 860-436-4364
MartinezCouch.com
MCA Consulting Engineers & Surveyors DBE/MBE Certified
Site/Civil Engineering | Land Surveying | Energy & Sustainability Wastewater Engineering | Mechanical/Electrical/Plumbing | GIS
CX103
DETAILS
6" 9"
2% MAX.
NTS
CONCRETE WALK
CLASS "F" CONCRETE
4,500 PSI
FINISH GRADE
GRANITE CURB
CONCRETE FILL 2" BELOW FINISHED
ASPHALT GRADE AT JOINTS
FINISH GRADE
BITUMINOUS CONCRETE
COMPACTED 34" AGGREGATE BASE (SUBSTITUTE
CONCRETE AT JOINTS)
COMPACTED OR UNDISTURBED EARTH
PROCESSED AGGREGATE BASE
COURSE. MATCH EXISTING DEPTH
MATCH EXISTING WIDTH
NOTES:
1. ALL PIECES SHALL BE 6'-0" LONG EXCEPT FOR CLOSURES WHERE NO PIECE LESS THAN 4'-0" LONG SHALL BE
USED.
2. CURBS OF RADIUS LESS THAN 100' SHALL BE CUT OR CAST TO REQUIRED RADIUS AND LENGTH.
3. USE 1/2" PREFORMED EXPANSION JOINT FILLER SPACED NOT MORE THAN 20'-0" O.C. FOR PRECAST OR
CAST-IN-PLACE CONCRETE CURB.
4. JOINT BETWEEN GRANITE OR CONCRETE SECTIONS ARE NOT TO EXCEED 1/2".
5. MINIMUM WIDTH OF CURB AT BOTTOM SHALL BE 4" OR NO GREATER THAN 2/3 THE HEIGHT OF THE PIECE.
6. CLASS "C" (AE) CONCRETE TO BE PLACED AT JOINTS AS SHOWN IN GRANITE CURB DETAIL, AND ALONG
STREET TRENCH AS SHOWN IN DETAIL.
7. TO BE USED AS INDICATED ON THE SITE PLAN
MATERIALS:
1. STONE FOR GRANITE CURBING SHALL BE HARD AND DURABLE GRANITE OF LIGHT COLOR AND UNIFORM
TEXTURE, NEITHER STRATIFIED NOR LAMINATED. IT SHALL BE FREE FROM SEAMS AND EVIDENCE OF WEAKENING OR DISINTEGRATION AND SHALL HAVE GOOD, SMOOTH SPLIT FACES. MATCH EXISTING COLOR
AND TEXTURE.
2. THE TOP SURFACE SHALL BE POINTED, PEEN HAMMERED AND SAWED. THE TOP 8 INCHES OF THE FACE SHALL BE SMOOTH QUARRY SPLIT AND FREE FROM DRILL HOLES. THE ENDS OF ALL STONES SHALL BE SQUARE WITH THE PLANES OF THE TOP AND FACE, AND SO FINISHED THAT WHEN STONES ARE PLACED END TO END AS CLOSELY AS POSSIBLE, NO SPACE MORE THAN 1/2 INCH SHALL SHOW IN THE JOINT FOR THE FULL WIDTH OF THE TOP OR THE TOP 8 INCHES OF THE FACE. THE TOP STREET SIDE FACE OF THE CURB SHALL NOT HAVE
SHARP EDGES.
NTS
PARTIAL ELEVATION
PLAN
CROSS SECTION
6" 90°90°
1/2" MAX.
GROUND
90°
MAX.
8"6"
" T
O
9"
1'-0"
6"
8"
1'-0"
6"
CROSS SECTION
6"
ASPHALT
CONCRETE FILL 2" BELOW
FINISHED ASPHALT. CLASS "C"
3,300 PSI
COMPACTED OR
UNDISTURBED EARTH (TYP.)
PROCESSES AGGREGATE
BASE (SUBSTITUTE
CONCRETE AT JOINTS)
MORTAR (OMIT AT
EXPANSION JOINTS)
CLASS "C" 3,300 PSI
CONCRETE (AT JOINTS)
FACE
REVEAL
NO PROJECTION TO FALL
OUTSIDE PLANE OF
BATTER 4" IN 12"
SAWED, POINTED OR
PEEN HAMMERED
PAVEMENT SECTION
CLASS "C"
3,300 PSI CONCRETE
STABILIZED SUB BASE
EDGE TO BE SAW CUT SMOOTH
AND SEALED WITH RC-2
BITUMINOUS SEALER
CT DOT FORM 817
EXISTING PAVEMENT
HOT ASPHALT SEAL CT DOT FORM 817
2" BITUMINOUS CONCRETE
CLASS 2 CT DOT FORM 817
2" BITUMINOUS CONCRETE
CLASS 1 CT DOT FORM 817
12" COMPACTED PROCESSED
AGGREGATE BASE
TACK COAT- TYPICAL ALL
ABUTTING PAVEMENT
SURFACES CT DOT FORM 817
1'-0" MIN. TRENCH WIDTH
VARIES 1'-0" MIN.
PAVEMENT REMOVAL
AND REPLACEMENT
WIDTH
NTS
NTS
NOTES:
1. ANY PEDESTRIAN RAMPS THAT ARE DISTURBED SHALL BE REPLACED IN-KIND GRADE THEN 6" LOAM AND SEED OR SOD ALL
AREAS NOT COVERED BY SIDEWALK OR PAVEMENT THAT ARE DISTURBED DURING SIDEWALK REMOVAL AND REPLACEMENT
2. MATCH SLOPE OF EXISTING SIDEWALK OR PROVIDE MAXIMUM 2% SLOPE
EPOXY COATED 6"x6" #8
WELDED WIRE FABRIC
CLASS "F" 4,500 PSI
CONCRETESLOPE 2% MAX.
NOTE 4
LOAM AND SEED
OR SOD (TYP)
SEE NOTE 3
FINISHED GRADE
UNDISTURBED SOIL
PROCESSED
AGGREGATE BASE
COURSE
8" THICK SIDEWALK 5" THICK SIDEWALK
12"
8"
3"
WIDTH VARIES
3"
EPOXY COATED 6"x6" #8
WELDED WIRE FABRIC
CLASS "F" 4,500 PSI
CONCRETE
SLOPE
2% MAX.
NOTE 4
LOAM AND SEED
OR SOD (TYP)
SEE NOTE 3
FINISHED GRADE
UNDISTURBED SOIL
PROCESSED
AGGREGATE BASE
COURSE
12"
5"
3"
WIDTH VARIES
3"
IN CASE OF DAMAGE TO SIDEWALKS OR CURBS, REPAIRS ARE TO
BE MADE IN ACCORDANCE WITH DETAILS IN THIS SHEET
GENERAL NOTES:
CUT & PATCH EXISTING BITUMINOUS
CONCRETE PAVEMENT. CONTRACTOR TO
MATCH EXISTING BITUMINOUS PAVEMENT
DEPTH WITH BITUMINOUS CLASS 2.
CUT & PATCH EXISTING BITUMINOUS
CONCRETE PAVEMENT. CONTRACTOR TO
MATCH EXISTING BITUMINOUS PAVEMENT
DEPTH WITH BITUMINOUS CLASS 1.
SAWCUT IN EXISTING
PAVEMENT
8"
6"
1'-6"
18"24"
PROCESSES
AGGREGATE BASE