This document contains the results of lead wipe sampling conducted at Cape Hatteras Lighthouse. The sampling was performed over five events - an initial background sampling and four additional samplings after cleaning. A total of 18 samples were collected from flooring and window sills at each event and analyzed for lead concentration. The initial sampling found levels exceeding EPA standards on most surfaces tested. The first three post-cleaning samplings still detected lead above clearance thresholds on many areas. By the fourth sampling, only one floor surface remained above standards. The reports summarize the sampling locations and results, finding some reduction in lead levels after each cleaning.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

# Sample ID Location Method

Results

07/16/21

Results

09/27/21

Results

03/28/22

Results

04/01/22

Results

04/07/22

Results

04/14/22

1 EXT-R Exterior Landing Random 3600 230 220 450 39 230

2 FL1-C 1st Floor Landing Consistent 360 4000 130 130 37

3 FL2-R 2nd Floor Landing Random 1700 3000 53 31 28

4 WS2-R 2nd Floor Window Sill Random 690 150 140

5 FL3-C 3rd Floor Landing Consistent 1900 74 23 21

6 WS3-R 3rd Floor Window Sill Random 150 470

7 FL4-R 4th Floor Landing Random 48 1600 97 40 24

8 WS4-R 4th Floor Window Sill Random 2400 1000 210

9 FL5-C 5th Floor Landing Consistent 830 1700 190 35 23

10 WS5-R 5th Floor Window Sill Random 360 370

11 FL6-R 6th Floor Landing Random 4900 140 240 21

12 WS6-C 6th Floor Window Sill Consistent 41 360 180 150 86

13 FL7-C 7th Floor Landing Consistent 200 3600 400 93 55

14 WS7-R 7th Floor Window Sill Random 430 490

15 FL8-R 8th Floor Landing Random 630 5100 130 44 34

16 WS8-R 8th Floor Window Sill Random 1000 240

17 FL9-C 9th Floor Landing Consistent 2300 680 60 60

18 WS9-C 9th Floor Window Sill Consistent 220 2800 380 100 150

19 FL10-R 10th Floor Landing Random 620 3000 630 61 160

HATTERAS LIGHTHOUSE LEAD TESTING SUMMARY

Highlighted cells indicate an increase from previous results. Numbers in bold indicate a passing result under previous EPA clearance levels

(40ug/sf on floors and 250ug/sf on sills).

Summary of Material & Equipment Usage

Note: 7th floor window fell from the Lighthouse prior to the 04/01/22 testing and dust was noticed around the window during testing. Likewise, dust was noticed on floors 6-8 during remaining testing dates.

2401 Brentwood Road, Suite 107

Raleigh, North Carolina 27604

P (919) 873-2211

Terracon.com

April 8, 2022

Heritage Contracting

201 Dexter Street West, Suite 104

Chesapeake, Virginia 23324

Attn: Eric Dryfka

P: (757) 472-4630

E: edryfka@heritage-contracting.com

Re: Limited Lead Wipe Sampling Report – Background Sampling

Cape Hatteras Lighthouse

46379 Lighthouse Road

Buxton, North Carolina 27920

Terracon Project No.: 70227071

Dear Mr. Dryfka:

Terracon Consultants, Inc. (Terracon) is pleased to present the results of the limited lead wipe sampling performed at the Cape Hatteras Lighthouse located in Buxton, North Carolina. The sampling was conducted on March 28, 2022, in general accordance with Terracon proposal P70227071, dated

February 3, 2022.

A. PROJECT INFORMATION

Terracon previously provided lead consulting services at the lighthouse as part of the National Park

Service (NPS) restoration project for QuinnEvans. NPS representatives requested that Heritage conduct additional cleaning inside the lighthouse in an attempt to reduce lead dust levels on the floors and windows sills below the current Environmental Protection Agency (EPA) and Housing and Urban

Development (HUD) lead dust standards.

The current scope of work is to perform additional lead wipe sampling before the first cleaning event

(background) and after each of the three planned cleaning events, for a total of four sampling events.

The scope of services was limited to collecting lead wipe samples in the lighthouse and reporting the laboratory results.

B. SAMPLING AND ANALYSIS METHODS

Terracon collected 18 lead wipe samples from surfaces throughout the lighthouse prior to additional cleaning activities. The lead wipe sampling was conducted by Terracon representative, Christian Borrel.

The sample locations were selected at the discretion of Terracon’s representative or at the direction of the Heritage Contracting representative present at the time of the sampling.

The samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker and submitted for analysis under a chain of custody to Scientific Analytical Institute, Inc. (SAI) in Greensboro, North Carolina. The samples were analyzed by Flame Atomic Absorption

Limited Lead Wipe Sampling Report – Background Sampling

46379 Lighthouse Road ■ Buxton, North Carolina

April 8, 2022 ■ Terracon Project No. 70227071 under method SW846-3050B/6010C/7000B. SAI is accredited by the American Industrial Hygiene

Association (AIHA®) Environmental Lead Proficiency Analytical Testing Program (ELPAT No. 173190) for lead laboratory analysis.

C. RESULTS

Lead was detected in the ten interior floor wipe samples collected in concentrations between 1,600 micrograms per square foot (µg/ft2) and 5,100 µg/ft2. Lead was detected in the five window sill wipe samples collected in concentrations between 360 µg/ft2 and 2,800 µg/ft2. In addition, the wipe sample collected from the exterior granite entry landing had lead detected in a concentration of 220 µg/ft2.

The two quality control samples had no detectable lead concentration.

Based on these results, the surfaces tested had levels of lead above the respective current

Environmental Protection Agency (EPA) and Housing and Urban Development (HUD) lead dust clearance standards of 10 µg/ft2 for floors, 100 µg/ft2 for window sills, and 40 µg/ft2 for porches (the nearest comparable standard for the exterior sample). The lead wipe sampling data form and laboratory analytical results follow as attachments to this report.

D. LIMITATIONS

The limited lead wipe sampling was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, and/or conclusions expressed in the report are based on conditions observed during the lead wipe sampling event. This report has been prepared on behalf of and exclusively for use and reliance by Heritage Contracting. This report is not a bidding document.

Contractors or consultants reviewing this lead wipe sampling report must draw their own conclusions regarding further investigation or abatement deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information that may have been used in preparation of this report. No warranty, express or implied, is made.

Terracon appreciates the opportunity to provide lead wipe sampling services to you. If you have any questions regarding the content of this report, or if we can be of further assistance, please contact us at

(919) 873-2211.

Sincerely, Terracon Consultants, Inc.

Alicia Coley, CIH For: Russell Harrings, CIH Project Industrial Hygienist Authorized Project Reviewer

Attachments: Lead Wipe Sampling Summary Table

Laboratory Results

Lead Wipe Sampling Summary Table

46379 Lighthouse Road

Buxton, North Carolina 27920

Terracon Project No. 70227071

Sample

ID

Material Description

Result

Unit

FLOOR WIPE SAMPLES

EXT-R Exterior – Front Entrance Granite 220 µg/ft2

FL1-C 1st Floor – Marble Floor 4,000 µg/ft2

FL2-R 2nd Floor – Marble Floor 3,000 µg/ft2

FL3-C 3rd Floor – Marble Floor 1,900 µg/ft2

FL4-R 4th Floor – Marble Floor 1,600 µg/ft2

FL5-C 5th Floor – Marble Floor 1,700 µg/ft2

FL6-R 6th Floor – Marble Floor 4,900 µg/ft2

FL7-C 7th Floor – Marble Floor 3,600 µg/ft2

FL8-R 8th Floor – Marble Floor 5,100 µg/ft2

FL9-C 9th Floor – Metal Floor 2,300 µg/ft2

FL10-R 10th Floor – Metal Floor 3,000 µg/ft2

WINDOW SILL WIPE SAMPLES

WS2-R 2nd Floor – Window Sill 690 µg/ft2

WS4-R 4th Floor – Window Sill 1,000 µg/ft2

WS6-C 6th Floor – Window Sill 360 µg/ft2

WS8-R 8th Floor – Window Sill 1,000 µg/ft2

WS9-C 9th Floor – Window Sill 2,800 µg/ft2

Bolded samples indicate wipe samples with lead concentrations above the EPA and HUD lead dust standards.

Terracon 2401 Brentwood Rd, Suite 107 Raleigh, NC 27604

Customer:

Analysis ID: 71988723_PBW

Attn: Anthony Scialdone

Date Reported: 3/30/2022

Date Received: 3/30/2022

Project: Cape Hatteras Lighthouse

Lab Order ID: 71988723

Lab Notes

Description

Lab Sample ID

Sample ID

Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy

EPA SW-846 3050B/6010C/7000B

Concentration

(µg)(ft²)

Area Concentration

(µg/ft²)

71988723PBW_1

Outdoor/ lm entrance/graniteEXT-R 2201 220

71988723PBW_2

Indoor/ 1st floor/marble tileFL1-C 40001 4000

71988723PBW_3

2nd floor/ marble tileFL2-R 30001 3000

71988723PBW_4

2nd floor/ window sillWS2-R

4000.58 690

71988723PBW_5

3rd floor/ marble tileFL3-C 19001 1900

71988723PBW_6

4th floor/ marble tileFL4-R 16001 1600

71988723PBW_7

4th floor/ window sillWS4-C

6100.58 1000

71988723PBW_8

5th floor/ marble tileFL5-C 17001 1700

71988723PBW_9

6th floor/ marble tileFL6-R 49001 4900

71988723PBW_10

6th floor/ window sillWS6-C

2100.58 360

Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 25ml sample is 2µg Total Pb). Unless indicated, areas and volumes were provided by the customer.

Athena Summa (18)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Analyst Laboratory Director

Page 1 of 2pbRpt_4.0.01_pbwI_v0.2

L-F-025 r15 2/14/2023

Raleigh, NC 27604

Customer:

Analysis ID: 71988723_PBW

Attn: Anthony Scialdone

Date Reported: 3/30/2022

Date Received: 3/30/2022

Project: Cape Hatteras Lighthouse

Lab Order ID: 71988723

Lab Notes

Description

Lab Sample ID

Sample ID

Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy

EPA SW-846 3050B/6010C/7000B

Concentration

(µg)(ft²)

Area Concentration

(µg/ft²)

71988723PBW_11

7th floor/ marble floorFL7-C 36001 3600

71988723PBW_12

8th floor/ marble floorFL8-R 51001 5100

71988723PBW_13

8th floor/ window sillWS8-R

6100.58 1000

71988723PBW_14

9th floor/ metal platformFL9-C 23001 2300

71988723PBW_15

9th floor/ window sillWS9-C 28001 2800

71988723PBW_16

10th floor/ metal platformFL10-R 30001 3000

71988723PBW_17

Blank wipeBL1 < 2.0- -

71988723PBW_18

Blank wipeBL2 < 2.0- -

Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 25ml sample is 2µg Total Pb). Unless indicated, areas and volumes were provided by the customer.

Athena Summa (18)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Analyst Laboratory Director

Page 2 of 2pbRpt_4.0.01_pbwI_v0.2

. ·~ c~ -• ~,&J: Scientific Analytical Institute L(lb Use Only I I {)A '-..Z---1 Lab Order ID: ~ vt DI::> L

Client Code: ,,--' ·,: ..

4604 Dundas Dr. Greensboro, NC 27407 Phone: 336.292.3888 Fax: 336.292.3313

/ www.sailab.com lab@sailab.com

Contact Information -:·.,.

Company Name: Terracon Company: .

Address: 2401 Bre11twood Rd Suite 106 Address:

Raleigh, NC 27604

Contact:

Contact: Pirone 0:

Plrolle 0: Fax0:

Fax0: Email 0:

Email IBf:

PO Number:

Lead Test T _. -es ...... · .... 12 Hours Paint Chips by Flame AA O Soil by Flame AA 0 (PBP (PBS Other D 24 Hours

Wipe by Flame AA i8J. Air by Flame AA 0 (PBW) (PBA 48 Hours

.L

• 120 Hours

• 144+ Hours

01 02

03 04

05 06

07 08

09 10

11 12

13 14

P (919) 873-2211 Terracon.com

April 20, 2022

Heritage Contracting 201 Dexter Street West, Suite 104 Chesapeake, Virginia 23324

Attn: Eric Dryfka P: (757) 472-4630 E: edryfka@heritage-contracting.com

Re: Limited Lead Wipe Sampling Report – First Cleaning Sampling Cape Hatteras Lighthouse 46379 Lighthouse Road Buxton, North Carolina 27920 Terracon Project No.: 70227071

Dear Mr. Dryfka:

Terracon Consultants, Inc. (Terracon) is pleased to present the results of the limited lead wipe sampling event performed at the Cape Hatteras Lighthouse located in Buxton, North Carolina. This sampling was conducted after the first cleaning event on April 1, 2022, in general accordance with Terracon proposal P70227071, dated February 3, 2022.

PROJECT INFORMATION

Terracon previously provided lead consulting services at the lighthouse as part of the National Park Service (NPS) restoration project for QuinnEvans. U.S. National Park Services (NPS) representatives requested that Heritage conduct additional cleaning inside the lighthouse in an attempt to reduce lead dust levels on the floors and windows sills below the current Environmental Protection Agency (EPA) and Housing and Urban Development (HUD) lead dust standards.

The current scope of work is to perform additional lead wipe sampling before the first cleaning event (background) and after each of the three planned cleaning events, for a total of four sampling events.

The scope of services was limited to collecting lead wipe samples in the lighthouse and reporting the laboratory results.

SAMPLING AND ANALYSIS METHODS

Terracon collected 18 lead wipe samples from surfaces throughout the lighthouse following a first round of additional cleaning activities. The lead wipe sampling was conducted by Terracon representative, Christian Borrel. The sample locations were selected at the discretion of Terracon’s representative or at the direction of the Heritage Contracting representative present at the time of the sampling.

The samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker and submitted for analysis under a chain of custody to Scientific Analytical Institute, Limited Lead Wipe Sampling Report – First Cleaning Sampling

46379 Lighthouse Road ■ Buxton, North Carolina April 20, 2022 ■ Terracon Project No. 70227071

Association (AIHA®) Environmental Lead Proficiency Analytical Testing Program (ELPAT No. 173190) for lead laboratory analysis.

RESULTS

Lead was detected in the ten interior floor wipe samples collected in concentrations between 43 micrograms per square foot (µg/ft2) and 680 µg/ft2. Lead was detected in the five window sill wipe samples collected in concentrations between 290 µg/ft2 and 810 µg/ft2. In addition, the wipe sample collected from the exterior granite entry landing had lead detected in a concentration of 450 µg/ft2.

The two quality control samples had no detectable lead concentration.

Based on these results, the surfaces tested had levels of lead above the respective current Environmental Protection Agency (EPA) and Housing and Urban Development (HUD) lead dust clearance standards of 10 µg/ft2 for floors, 100 µg/ft2 for window sills, and 40 µg/ft2 for porches (the nearest comparable standard for the exterior sample). The lead wipe sampling data form and laboratory analytical results follow as attachments to this report.

LIMITATIONS

The limited lead wipe sampling was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, and/or conclusions expressed in the report are based on conditions observed during the lead wipe sampling event. This report has been prepared on behalf of and exclusively for use and reliance by Heritage Contracting. This report is not a bidding document.

Contractors or consultants reviewing this lead wipe sampling report must draw their own conclusions regarding further investigation or abatement deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information that may have been used in preparation of this report. No warranty, express or implied, is made.

Terracon appreciates the opportunity to provide lead wipe sampling services to you. If you have any questions regarding the content of this report, or if we can be of further assistance, please contact us at

(919) 873-2211.

Sincerely, Terracon Consultants, Inc.

For Alicia Coley, CIH Russell Harrings, CIH Project Industrial Hygienist Authorized Project Reviewer

Sampling performed on 04/01/2022 following the First Cleaning Event

Cape Hatteras Lighthouse 46379 Lighthouse Road

Buxton, North Carolina 27920 Terracon Project No. 70227071

Sample ID Material Description Result Unit

FLOOR WIPE SAMPLES

EXT-R Exterior – Front Entrance Granite 450 µg/ft2

FL1-C 1st Floor – Marble Floor 130 µg/ft2

FL2-R 2nd Floor – Marble Floor 53 µg/ft2

FL3-C 3rd Floor – Marble Floor 43 µg/ft2

FL4-R 4th Floor – Marble Floor 97 µg/ft2

FL5-C 5th Floor – Marble Floor 110 µg/ft2

FL6-R 6th Floor – Marble Floor 86 µg/ft2

FL7-C 7th Floor – Marble Floor 250 µg/ft2

FL8-R 8th Floor – Marble Floor 130 µg/ft2

FL9-C 9th Floor – Metal Floor 680 µg/ft2

FL10-R 10th Floor – Metal Floor 630 µg/ft2

WINDOW SILL WIPE SAMPLES

WS3-R 3rd Floor – Window Sill 810 µg/ft2

WS5-R 5th Floor – Window Sill 640 µg/ft2

WS6-C 6th Floor – Window Sill 290 µg/ft2

WS7-R 7th Floor – Window Sill 680 µg/ft2

WS9-C 9th Floor – Window Sill 380 µg/ft2

Raleigh, NC 27604

Customer:

Analysis ID: 71989081_PBW

Attn: Anthony Scialdone

Date Amended: 4/6/2022

Date Reported: 4/4/2022

Date Received: 4/4/2022

Project: Cape Hatteras Lighthouse

Lab Order ID: 71989081

Lab Notes

Description

Lab Sample ID

Sample ID

Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy

EPA SW-846 3050B/6010C/7000B

Concentration

(µg)(ft²)

Area Concentration

(µg/ft²)

71989081PBW_1

Exterior/ lh entrance/ graniteEXT-R 4501 450

71989081PBW_2

Interior/ 1st floor/ marble tileFL1-C 1301 130

71989081PBW_3

2nd floor/ marble tileFL2-R 531 53

71989081PBW_4

3rd Floor/ marble tileFL3-C 431 43

71989081PBW_5

3rd Floor / window sill / metalWS3-R

4700.58 810

71989081PBW_6

4th Floor/ marble tileFL4-R 971 97

71989081PBW_7

5th Floor/ marble tileFL5-C 1101 110

71989081PBW_8

5th Floor/ window sill/ metalWS5-R

3600.57 640

71989081PBW_9

6th Floor/ marble tileFL-6 861 86

71989081PBW_10

6th Floor/ window sill/ metalWS6-C

1800.62 290

Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 25ml sample is 2µg Total Pb). Unless indicated, areas and volumes were provided by the customer.

Athena Summa (18)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Analyst Laboratory Director

Raleigh, NC 27604

Customer:

Analysis ID: 71989081_PBW

Attn: Anthony Scialdone

Date Amended: 4/6/2022

Date Reported: 4/4/2022

Date Received: 4/4/2022

Project: Cape Hatteras Lighthouse

Lab Order ID: 71989081

Lab Notes

Description

Lab Sample ID

Sample ID

Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy

EPA SW-846 3050B/6010C/7000B

Concentration

(µg)(ft²)

Area Concentration

(µg/ft²)

71989081PBW_11

7th Floor/ marble tileFL7-C 2501 250

71989081PBW_12

7th Floor/ window sill/ metalWS7-R

4300.63 680

71989081PBW_13

8th Floor/ marble tileFL8-R 1301 130

71989081PBW_14

9th floor/ metal platformFL9-C 6801 680

71989081PBW_15

9th Floor/ window sill/ metalWS9-C 3801 380

71989081PBW_16

10th Floor/ metal platformFL10-R 6301 630

71989081PBW_17

Blank wipeBL1 < 2.0- -

71989081PBW_18

Blank wipeBL2 < 2.0- -

Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 25ml sample is 2µg Total Pb). Unless indicated, areas and volumes were provided by the customer.

Athena Summa (18)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Analyst Laboratory Director lA'.J

Scientific Analytical Institute Lab Use Only 1 \ f'-A c / q O r/1 Lab Order ID: -'-. _v_L~---~- I

4604 Dundas Dr. Greensboro, NC 27407 Phone: 336.292.3888 Fax: 336.292.3313 Client Code: _____ _

/ www.sailab.com lab@sailab.com

Contaet Informatio,n Compa1iy Name: Terracon

Address: 2401 Brentwood Rd Suite 106

Raleigh, NC 27604

Contact:

Pliolle 0:

Fax0:

Lead Te-st T .. , es Paint Chips by Flame AA O Soil by Flame AA

(PBP PBS

Wipe by Flame AA

(PBW

Air by Flame AA 0

(PBA

Other D

Company: .

Address:

Contact:

Phone 0:

Fax0:

Email 0:

:,-~n;~ o, --",-ta; Tfnf "i _, ~T '..,_ ,• ,-.;:;._ ,.-_-• • ""_,,,, .... __ ~' ~~:'-._ ~ ...,_ ,,,..,__ ... ,!ffi~< ,_ .; -- 3 Hours □ 72 Hours

6 Hours IX' 96 Hours

12 Hours □ 120 Hours

24 Hours □ 144+ Hours

48 Hours □

EXT-R FL1-C

FL2-R FL3-C

WS3-R FL4-R

FL5-C WS5-R

FL6-R WS6-C

FL7-C WS7-R

FL8-R FL9-C

WS9-C FL10-R

P (919) 873-2211 Terracon.com

April 20, 2022

Heritage Contracting 201 Dexter Street West, Suite 104 Chesapeake, Virginia 23324

Attn: Eric Dryfka P: (757) 472-4630 E: edryfka@heritage-contracting.com

Re: Limited Lead Wipe Sampling Report – Second Cleaning Sampling Cape Hatteras Lighthouse 46379 Lighthouse Road Buxton, North Carolina 27920 Terracon Project No.: 70227071

Dear Mr. Dryfka:

Terracon Consultants, Inc. (Terracon) is pleased to present the results of the limited lead wipe sampling event performed at the Cape Hatteras Lighthouse located in Buxton, North Carolina. This sampling was conducted after the second cleaning event on April 8, 2022, in general accordance with Terracon proposal P70227071, dated February 3, 2022.

PROJECT INFORMATION

Terracon previously provided lead consulting services at the lighthouse as part of the National Park Service (NPS) restoration project for QuinnEvans. U.S. National Park Services (NPS) representatives requested that Heritage conduct additional cleaning inside the lighthouse in an attempt to reduce lead dust levels on the floors and windows sills below the current Environmental Protection Agency (EPA) and Housing and Urban Development (HUD) lead dust standards.

The current scope of work is to perform additional lead wipe sampling before the first cleaning event (background) and after each of the three planned cleaning events, for a total of four sampling events.

The scope of services was limited to collecting lead wipe samples in the lighthouse and reporting the laboratory results.

SAMPLING AND ANALYSIS METHODS

Terracon collected 18 lead wipe samples from surfaces throughout the lighthouse following a second round of additional cleaning activities. The lead wipe sampling was conducted by Terracon representative, Christian Borrel. The sample locations were selected at the discretion of Terracon’s representative or at the direction of the Heritage Contracting representative present at the time of the sampling.

The samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker and submitted for analysis under a chain of custody to Scientific Analytical Institute, Limited Lead Wipe Sampling Report – Second Cleaning Sampling

46379 Lighthouse Road ■ Buxton, North Carolina April 20, 2022 ■ Terracon Project No. 70227071 under method SW846-3050B/6010C/7000B. SAI is accredited by the American Industrial Hygiene Association (AIHA®) Environmental Lead Proficiency Analytical Testing Program (ELPAT No. 173190) for lead laboratory analysis.

RESULTS

Lead was detected in the ten interior floor wipe samples collected in concentrations between 23 micrograms per square foot (µg/ft2) and 240 µg/ft2. Lead was detected in the five window sill wipe samples collected in concentrations between 100 µg/ft2 and 240 µg/ft2. In addition, the wipe sample collected from the exterior granite entry landing had lead detected in a concentration of 39 µg/ft2.

The two quality control samples had no detectable lead concentration.

Based on these results, most of the surfaces tested had levels of lead still above the respective current Environmental Protection Agency (EPA) and Housing and Urban Development (HUD) lead dust clearance standards of 10 µg/ft2 for floors, 100 µg/ft2 for window sills, and 40 µg/ft2 for porches (the nearest comparable standard for the exterior sample). The exterior front entrance sample (39 µg/ft2) and the 9th floor window sill sample (100 µg/ft2) had concentrations at or below the clearance thresholds. The lead wipe sampling data form and laboratory analytical results follow as attachments to this report.

LIMITATIONS

The limited lead wipe sampling was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, and/or conclusions expressed in the report are based on conditions observed during the lead wipe sampling event. This report has been prepared on behalf of and exclusively for use and reliance by Heritage Contracting. This report is not a bidding document.

Contractors or consultants reviewing this lead wipe sampling report must draw their own conclusions regarding further investigation or abatement deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information that may have been used in preparation of this report. No warranty, express or implied, is made.

Terracon appreciates the opportunity to provide lead wipe sampling services to you. If you have any questions regarding the content of this report, or if we can be of further assistance, please contact us at

(919) 873-2211.

Sincerely, Terracon Consultants, Inc.

For Alicia Coley, CIH Russell Harrings, CIH Project Industrial Hygienist Authorized Project Reviewer

Sampling performed on 04/08/2022 following the Second Cleaning Event

Cape Hatteras Lighthouse 46379 Lighthouse Road

Buxton, North Carolina 27920 Terracon Project No. 70227071

Sample ID Material Description Result Unit

FLOOR WIPE SAMPLES

EXT-R Exterior – Front Entrance Granite 39 µg/ft2

FL1-C 1st Floor – Marble Floor 130 µg/ft2

FL2-R 2nd Floor – Marble Floor 31 µg/ft2

FL3-C 3rd Floor – Marble Floor 23 µg/ft2

FL4-R 4th Floor – Marble Floor 40 µg/ft2

FL5-C 5th Floor – Marble Floor 35 µg/ft2

FL6-R 6th Floor – Marble Floor 240 µg/ft2

FL7-C 7th Floor – Marble Floor 93 µg/ft2

FL8-R 8th Floor – Marble Floor 44 µg/ft2

FL9-C 9th Floor – Metal Floor 60 µg/ft2

FL10-R 10th Floor – Metal Floor 61 µg/ft2

WINDOW SILL WIPE SAMPLES

WS2-R 2nd Floor – Window Sill 150 µg/ft2

WS4-R 4th Floor – Window Sill 210 µg/ft2

WS6-C 6th Floor – Window Sill 150 µg/ft2

WS8-R 8th Floor – Window Sill 240 µg/ft2

WS9-C 9th Floor – Window Sill 100 µg/ft2

Raleigh, NC 27604

Customer:

Analysis ID: 71989627_PBW

Attn: Anthony Scialdone

Date Reported: 4/11/2022

Date Received: 4/11/2022

Project: Cape Hatteras Lighthouse

Lab Order ID: 71989627

Lab Notes

Description

Lab Sample ID

Sample ID

Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy

EPA SW-846 3050B/6010C/7000B

Concentration

(µg)(ft²)

Area Concentration

(µg/ft²)

71989627PBW_1

Exterior/entrance/stoneEXT-R 391 39

71989627PBW_2

1st floor/floor/marbleFL1-C 1301 130

71989627PBW_3

2nd floor/floor/marbleFL2-R 311 31

71989627PBW_4

2nd floor/window sill/metalWS2-R

930.64 150

71989627PBW_5

3rd floor/floor/marbleFL3-C 231 23

71989627PBW_6

4th floor/floor/marbleFL4-R

40.1 40.

71989627PBW_7

4th floor/window sill/metalWS4-R

1400.68 210

71989627PBW_8

5th floor/floor/marbleFL5-C 351 35

71989627PBW_9

6th floor/floor/marbleFL6-R 2401 240

71989627PBW_10

6th floor/window sill/metalWS6-C

1000.67 150

Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 25ml sample is 2µg Total Pb). Unless indicated, areas and volumes were provided by the customer.

Xaviera Watkins (18)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Analyst Laboratory Director

Raleigh, NC 27604

Customer:

Analysis ID: 71989627_PBW

Attn: Anthony Scialdone

Date Reported: 4/11/2022

Date Received: 4/11/2022

Project: Cape Hatteras Lighthouse

Lab Order ID: 71989627

Lab Notes

Description

Lab Sample ID

Sample ID

Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy

EPA SW-846 3050B/6010C/7000B

Concentration

(µg)(ft²)

Area Concentration

(µg/ft²)

71989627PBW_11

7th floor/floor/marbleFL7-C 931 93

71989627PBW_12

8th floor/floor/marbleFL8-R 441 44

71989627PBW_13

8th floor/window sill/marbleWS8-R

1600.68 240

71989627PBW_14

9th floor/floor/marbleFL9-C

60.1 60.

71989627PBW_15

9th floor/window sill/metalWS9-C 1001 100

71989627PBW_16

10th floor/floor/marbleFL10-R 611 61

71989627PBW_17

BlankBL1 < 2.0- -

71989627PBW_18

BlankBL2 < 2.0- -

Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 25ml sample is 2µg Total Pb). Unless indicated, areas and volumes were provided by the customer.

Xaviera Watkins (18)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Analyst Laboratory Director

EXT R - R FLR 1 - C

WS – 2 R FLR 2 -R

FLR – 3 C FLR – 4 R

WS – 4 R FLR – 5 C

FLR – 6 R WS – 6 C

FLR 7 - C FLR 8 - R

WS – 8 R FLR – 9 C

WS – 9 C FLR 10 – R

P (919) 873-2211 Terracon.com

April 21, 2022

Heritage Contracting 201 Dexter Street West, Suite 104 Chesapeake, Virginia 23324

Attn: Eric Dryfka P: (757) 472-4630 E: edryfka@heritage-contracting.com

Re: Limited Lead Wipe Sampling Report – Third Cleaning Sampling Cape Hatteras Lighthouse 46379 Lighthouse Road Buxton, North Carolina 27920 Terracon Project No.: 70227071

Dear Mr. Dryfka:

Terracon Consultants, Inc. (Terracon) is pleased to present the results of the limited lead wipe sampling event performed at the Cape Hatteras Lighthouse located in Buxton, North Carolina. This sampling was conducted after the third cleaning event on April 14, 2022, in general accordance with Terracon proposal P70227071, dated February 3, 2022.

PROJECT INFORMATION

Terracon previously provided lead consulting services at the lighthouse as part of the National Park Service (NPS) restoration project for Quinn Evans. U.S. National Park Services (NPS) representatives requested that Heritage conduct additional cleaning inside the lighthouse in an attempt to reduce lead dust levels on the floors and windows sills below the current Environmental Protection Agency (EPA) and Housing and Urban Development (HUD) lead dust standards.

The current scope of work is to perform additional lead wipe sampling before the first cleaning event (background) and after each of the three planned cleaning events, for a total of four sampling events.

The scope of services was limited to collecting lead wipe samples in the lighthouse and reporting the laboratory results.

SAMPLING AND ANALYSIS METHODS

Terracon collected 18 lead wipe samples from surfaces throughout the lighthouse following a third round of additional cleaning activities. The lead wipe sampling was conducted by Terracon representative, Christian Borrel. The sample locations were selected at the discretion of Terracon’s representative or at the direction of the Heritage Contracting representative present at the time of the sampling.

The samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker and submitted for analysis under a chain of custody to Scientific Analytical Institute, Limited Lead Wipe Sampling Report – Third Cleaning Sampling

46379 Lighthouse Road ■ Buxton, North Carolina April 21, 2022 ■ Terracon Project No. 70227071

Association (AIHA®) Environmental Lead Proficiency Analytical Testing Program (ELPAT No. 173190) for lead laboratory analysis.

RESULTS

Lead was detected in the ten interior floor wipe samples collected in concentrations between 21 micrograms per square foot (µg/ft2) and 160 µg/ft2. Lead was detected in the five window sill wipe samples collected in concentrations between 86 µg/ft2 and 490 µg/ft2. In addition, the wipe sample collected from the exterior granite entry landing had lead detected in a concentration of 230 µg/ft2.

The two quality control samples had no detectable lead concentration.

Based on these results, most of the surfaces tested, except one surface, had levels of lead still above the respective current Environmental Protection Agency (EPA) and Housing and Urban Development (HUD) lead dust clearance standards of 10 µg/ft2 for floors, 100 µg/ft2 for window sills, and 40 µg/ft2 for porches (the nearest comparable standard for the exterior sample). The 6th floor window sill sample (86 µg/ft2) had a lead concentration below the clearance threshold. The lead wipe sampling data form and laboratory analytical results follow as attachments to this report.

LIMITATIONS

The limited lead wipe sampling was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, and/or conclusions expressed in the report are based on conditions observed during the lead wipe sampling event. This report has been prepared on behalf of and exclusively for use and reliance by Heritage Contracting. This report is not a bidding document.

Contractors or consultants reviewing this lead wipe sampling report must draw their own conclusions regarding further investigation or abatement deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information that may have been used in preparation of this report. No warranty, express or implied, is made.

Terracon appreciates the opportunity to provide lead wipe sampling services to you. If you have any questions regarding the content of this report, or if we can be of further assistance, please contact us at

(919) 873-2211.

Sincerely, Terracon Consultants, Inc.

For Alicia Coley, CIH Russell Harrings, CIH Project Industrial Hygienist Authorized Project Reviewer

Sampling performed on 04/14/2022 following the Third Cleaning Event

Cape Hatteras Lighthouse 46379 Lighthouse Road

Buxton, North Carolina 27920 Terracon Project No. 70227071

Sample ID Material Description Result Unit

FLOOR WIPE SAMPLES

EXT-R Exterior – Front Entrance Stone 230 µg/ft2

FL1-C 1st Floor – Marble Floor 37 µg/ft2

FL2-R 2nd Floor – Marble Floor 28 µg/ft2

FL3-C 3rd Floor – Marble Floor 21 µg/ft2

FL4-R 4th Floor – Marble Floor 24 µg/ft2

FL5-C 5th Floor – Marble Floor 23 µg/ft2

FL6-R 6th Floor – Marble Floor 21 µg/ft2

FL7-C 7th Floor – Marble Floor 55 µg/ft2

FL8-R 8th Floor – Marble Floor 34 µg/ft2

FL9-C 9th Floor – Metal Floor 60 µg/ft2

FL10-R 10th Floor – Metal Floor 160 µg/ft2

WINDOW SILL WIPE SAMPLES

WS2-R 2nd Floor – Window Sill 140 µg/ft2

WS5-R 5th Floor – Window Sill 370 µg/ft2

WS6-C 6th Floor – Window Sill 86 µg/ft2

WS7-R 7th Floor – Window Sill 490 µg/ft2

WS9-C 9th Floor – Window Sill 150 µg/ft2

Raleigh, NC 27604

Customer:

Analysis ID: 71990011_PBW

Attn: Anthony Scialdone

Date Reported: 4/15/2022

Date Received: 4/15/2022

Project: Cape Hatteras Lighthouse (4th sampling)

Lab Order ID: 71990011

Lab Notes

Description

Lab Sample ID

Sample ID

Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy

EPA SW-846 3050B/6010C/7000B

Concentration

(µg)(ft²)

Area Concentration

(µg/ft²)

71990011PBW_1

Exterior/Porch/StoneEXT-R 2301 230

71990011PBW_2

1st Floor/Floor/MarbleFL1-C 371 37

71990011PBW_3

2nd Floor/Floor/MarbleFL2-R 281 28

71990011PBW_4

2nd Floor/Window sill/MetalWS2-R

950.68 140

71990011PBW_5

3rd Floor/Floor/MarbleFL3-C 211 21

71990011PBW_6

4th Floor/Floor/MarbleFL4-R 241 24

71990011PBW_7

5th Floor/Floor/MarbleFL5-C 231 23

71990011PBW_8

5th Floor/Window sill/MetalWS5-R

2300.64 370

71990011PBW_9

6th Floor/Floor/MarbleFL6-R 211 21

71990011PBW_10

6th Floor/Window sill/MetalWS6-C

580.68 86

Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 25ml sample is 2µg Total Pb). Unless indicated, areas and volumes were provided by the customer.

Athena Summa (18)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Analyst Laboratory Director

Raleigh, NC 27604

Customer:

Analysis ID: 71990011_PBW

Attn: Anthony Scialdone

Date Reported: 4/15/2022

Date Received: 4/15/2022

Project: Cape Hatteras Lighthouse (4th sampling)

Lab Order ID: 71990011

Lab Notes

Description

Lab Sample ID

Sample ID

Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy

EPA SW-846 3050B/6010C/7000B

Concentration

(µg)(ft²)

Area Concentration

(µg/ft²)

71990011PBW_11

7th Floor/Floor/MarbleFL7-C 551 55

71990011PBW_12

7th Floor/Window sill/MetalWS7-R

3200.65 490

71990011PBW_13

8th Floor/Floor/MarbleFL8-R 341 34

71990011PBW_14

9th Floor/Floor/MetalFL9-C

60.1 60.

71990011PBW_15

9th Floor/Window sill/MetalWS9-C 1501 150

71990011PBW_16

10th Floor/Floor/MetalFL10-R 1601 160

71990011PBW_17

BlankBL1 < 2.0- -

71990011PBW_18

BlankBL2 < 2.0- -

Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 25ml sample is 2µg Total Pb). Unless indicated, areas and volumes were provided by the customer.

Athena Summa (18)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Analyst Laboratory Director

.-' r ,_ . ' 1it

1ki n Scientific Analytical Institute Lab Use Only 1 \ n\ °I (X)\ \

Lab Order ID:--'-l _ -_ I __ _.:.

4604 Dundas Dr. Greensboro, NC 27407 Phone: 336.292.3888 Fax: 336.292.331.3 Client Code: _____ _ www.sailab.com lab@sailab.com

ConJ:a,ct lnforl'IJation Compa11y Name: Terracon

Address: 2401 Brentwood Rd Suite 106

Raleigh, NC 27604

Contact:

Plwne 0:

Fax 0:

Email~

PO Number:

Paint Chips by Flame AA O Soil by Flame AA 0

(PBP (PBS)

Wipe by Flame AA

(PBW)

Air by Flame AA 0

(PBA

Other 0

Company: -

Address:

Contact:

P/zoneO:

Fax0:

Email 0:

3 Hours

6 Hours

12 Hours D 120 Hours

24 Hours D 144+ Hours

48 Hours •

Total Number of Samples J 6?

EXT - R FL1-C

FLR2 - R WS2-R

FLR-3 C

FLR- 4 R

FLR-5 C WS6 - C

FLR-6 R WS6-C

FLR- 7 C WS8-R

FLR-8 R FLR-9 C

FLR9-C

FLR 10-R

Hatteras Lead Testing Summary
03-28-22 Terracon Report
Initial Testing 3.28.22 71988723_PBW
Lead Testing Photos 03-28-22
04-01-22 Terracon Report
2b. Amended SAI Lead Wipe Sampling Results (04.06.2022)
04-01-22 Lead Testing Photos
04-08-22 Terracon Report
3. SAI Lead Wipe Sampling Results (04.11.2022)
04-08-22 Lead Test Photos
04-14-22 Terracon Report
4. SAI Lead Wipe Sampling Results (04.14.2022)

04-14-22 Lead Testing Images

File details come from the government source that posted it. Updated .