Attachment_4_Cape_Hatteras_Lead_Based_Paint_Report_-_R.pdf
PDF 4 MB Posted
- Attached to
- CAHA 213068 / Repair Cape Hatteras Lighthouse
- Solicitation number
- 140P2023R0132
About this file
This document contains the results of lead wipe sampling conducted at Cape Hatteras Lighthouse. The sampling was performed over five events - an initial background sampling and four additional samplings after cleaning. A total of 18 samples were collected from flooring and window sills at each event and analyzed for lead concentration. The initial sampling found levels exceeding EPA standards on most surfaces tested. The first three post-cleaning samplings still detected lead above clearance thresholds on many areas. By the fourth sampling, only one floor surface remained above standards. The reports summarize the sampling locations and results, finding some reduction in lead levels after each cleaning.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
# Sample ID Location Method
Results
07/16/21
Results
09/27/21
Results
03/28/22
Results
04/01/22
Results
04/07/22
Results
04/14/22
1 EXT-R Exterior Landing Random 3600 230 220 450 39 230
2 FL1-C 1st Floor Landing Consistent 360 4000 130 130 37
3 FL2-R 2nd Floor Landing Random 1700 3000 53 31 28
4 WS2-R 2nd Floor Window Sill Random 690 150 140
5 FL3-C 3rd Floor Landing Consistent 1900 74 23 21
6 WS3-R 3rd Floor Window Sill Random 150 470
7 FL4-R 4th Floor Landing Random 48 1600 97 40 24
8 WS4-R 4th Floor Window Sill Random 2400 1000 210
9 FL5-C 5th Floor Landing Consistent 830 1700 190 35 23
10 WS5-R 5th Floor Window Sill Random 360 370
11 FL6-R 6th Floor Landing Random 4900 140 240 21
12 WS6-C 6th Floor Window Sill Consistent 41 360 180 150 86
13 FL7-C 7th Floor Landing Consistent 200 3600 400 93 55
14 WS7-R 7th Floor Window Sill Random 430 490
15 FL8-R 8th Floor Landing Random 630 5100 130 44 34
16 WS8-R 8th Floor Window Sill Random 1000 240
17 FL9-C 9th Floor Landing Consistent 2300 680 60 60
18 WS9-C 9th Floor Window Sill Consistent 220 2800 380 100 150
19 FL10-R 10th Floor Landing Random 620 3000 630 61 160
HATTERAS LIGHTHOUSE LEAD TESTING SUMMARY
Highlighted cells indicate an increase from previous results. Numbers in bold indicate a passing result under previous EPA clearance levels
(40ug/sf on floors and 250ug/sf on sills).
Summary of Material & Equipment Usage
Note: 7th floor window fell from the Lighthouse prior to the 04/01/22 testing and dust was noticed around the window during testing. Likewise, dust was noticed on floors 6-8 during remaining testing dates.
2401 Brentwood Road, Suite 107
Raleigh, North Carolina 27604
P (919) 873-2211
Terracon.com
April 8, 2022
Heritage Contracting
201 Dexter Street West, Suite 104
Chesapeake, Virginia 23324
Attn: Eric Dryfka
P: (757) 472-4630
E: edryfka@heritage-contracting.com
Re: Limited Lead Wipe Sampling Report – Background Sampling
Cape Hatteras Lighthouse
46379 Lighthouse Road
Buxton, North Carolina 27920
Terracon Project No.: 70227071
Dear Mr. Dryfka:
Terracon Consultants, Inc. (Terracon) is pleased to present the results of the limited lead wipe sampling performed at the Cape Hatteras Lighthouse located in Buxton, North Carolina. The sampling was conducted on March 28, 2022, in general accordance with Terracon proposal P70227071, dated
February 3, 2022.
A. PROJECT INFORMATION
Terracon previously provided lead consulting services at the lighthouse as part of the National Park
Service (NPS) restoration project for QuinnEvans. NPS representatives requested that Heritage conduct additional cleaning inside the lighthouse in an attempt to reduce lead dust levels on the floors and windows sills below the current Environmental Protection Agency (EPA) and Housing and Urban
Development (HUD) lead dust standards.
The current scope of work is to perform additional lead wipe sampling before the first cleaning event
(background) and after each of the three planned cleaning events, for a total of four sampling events.
The scope of services was limited to collecting lead wipe samples in the lighthouse and reporting the laboratory results.
B. SAMPLING AND ANALYSIS METHODS
Terracon collected 18 lead wipe samples from surfaces throughout the lighthouse prior to additional cleaning activities. The lead wipe sampling was conducted by Terracon representative, Christian Borrel.
The sample locations were selected at the discretion of Terracon’s representative or at the direction of the Heritage Contracting representative present at the time of the sampling.
The samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker and submitted for analysis under a chain of custody to Scientific Analytical Institute, Inc. (SAI) in Greensboro, North Carolina. The samples were analyzed by Flame Atomic Absorption
Limited Lead Wipe Sampling Report – Background Sampling
46379 Lighthouse Road ■ Buxton, North Carolina
April 8, 2022 ■ Terracon Project No. 70227071 under method SW846-3050B/6010C/7000B. SAI is accredited by the American Industrial Hygiene
Association (AIHA®) Environmental Lead Proficiency Analytical Testing Program (ELPAT No. 173190) for lead laboratory analysis.
C. RESULTS
Lead was detected in the ten interior floor wipe samples collected in concentrations between 1,600 micrograms per square foot (µg/ft2) and 5,100 µg/ft2. Lead was detected in the five window sill wipe samples collected in concentrations between 360 µg/ft2 and 2,800 µg/ft2. In addition, the wipe sample collected from the exterior granite entry landing had lead detected in a concentration of 220 µg/ft2.
The two quality control samples had no detectable lead concentration.
Based on these results, the surfaces tested had levels of lead above the respective current
Environmental Protection Agency (EPA) and Housing and Urban Development (HUD) lead dust clearance standards of 10 µg/ft2 for floors, 100 µg/ft2 for window sills, and 40 µg/ft2 for porches (the nearest comparable standard for the exterior sample). The lead wipe sampling data form and laboratory analytical results follow as attachments to this report.
D. LIMITATIONS
The limited lead wipe sampling was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, and/or conclusions expressed in the report are based on conditions observed during the lead wipe sampling event. This report has been prepared on behalf of and exclusively for use and reliance by Heritage Contracting. This report is not a bidding document.
Contractors or consultants reviewing this lead wipe sampling report must draw their own conclusions regarding further investigation or abatement deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information that may have been used in preparation of this report. No warranty, express or implied, is made.
Terracon appreciates the opportunity to provide lead wipe sampling services to you. If you have any questions regarding the content of this report, or if we can be of further assistance, please contact us at
(919) 873-2211.
Sincerely, Terracon Consultants, Inc.
Alicia Coley, CIH For: Russell Harrings, CIH Project Industrial Hygienist Authorized Project Reviewer
Attachments: Lead Wipe Sampling Summary Table
Laboratory Results
Lead Wipe Sampling Summary Table
46379 Lighthouse Road
Buxton, North Carolina 27920
Terracon Project No. 70227071
Sample
ID
Material Description
Result
Unit
FLOOR WIPE SAMPLES
EXT-R Exterior – Front Entrance Granite 220 µg/ft2
FL1-C 1st Floor – Marble Floor 4,000 µg/ft2
FL2-R 2nd Floor – Marble Floor 3,000 µg/ft2
FL3-C 3rd Floor – Marble Floor 1,900 µg/ft2
FL4-R 4th Floor – Marble Floor 1,600 µg/ft2
FL5-C 5th Floor – Marble Floor 1,700 µg/ft2
FL6-R 6th Floor – Marble Floor 4,900 µg/ft2
FL7-C 7th Floor – Marble Floor 3,600 µg/ft2
FL8-R 8th Floor – Marble Floor 5,100 µg/ft2
FL9-C 9th Floor – Metal Floor 2,300 µg/ft2
FL10-R 10th Floor – Metal Floor 3,000 µg/ft2
WINDOW SILL WIPE SAMPLES
WS2-R 2nd Floor – Window Sill 690 µg/ft2
WS4-R 4th Floor – Window Sill 1,000 µg/ft2
WS6-C 6th Floor – Window Sill 360 µg/ft2
WS8-R 8th Floor – Window Sill 1,000 µg/ft2
WS9-C 9th Floor – Window Sill 2,800 µg/ft2
Bolded samples indicate wipe samples with lead concentrations above the EPA and HUD lead dust standards.
Terracon 2401 Brentwood Rd, Suite 107 Raleigh, NC 27604
Customer:
Analysis ID: 71988723_PBW
Attn: Anthony Scialdone
Date Reported: 3/30/2022
Date Received: 3/30/2022
Project: Cape Hatteras Lighthouse
Lab Order ID: 71988723
Lab Notes
Description
Lab Sample ID
Sample ID
Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy
EPA SW-846 3050B/6010C/7000B
Concentration
(µg)(ft²)
Area Concentration
(µg/ft²)
71988723PBW_1
Outdoor/ lm entrance/graniteEXT-R 2201 220
71988723PBW_2
Indoor/ 1st floor/marble tileFL1-C 40001 4000
71988723PBW_3
2nd floor/ marble tileFL2-R 30001 3000
71988723PBW_4
2nd floor/ window sillWS2-R
4000.58 690
71988723PBW_5
3rd floor/ marble tileFL3-C 19001 1900
71988723PBW_6
4th floor/ marble tileFL4-R 16001 1600
71988723PBW_7
4th floor/ window sillWS4-C
6100.58 1000
71988723PBW_8
5th floor/ marble tileFL5-C 17001 1700
71988723PBW_9
6th floor/ marble tileFL6-R 49001 4900
71988723PBW_10
6th floor/ window sillWS6-C
2100.58 360
Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 25ml sample is 2µg Total Pb). Unless indicated, areas and volumes were provided by the customer.
Athena Summa (18)
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Analyst Laboratory Director
Page 1 of 2pbRpt_4.0.01_pbwI_v0.2
L-F-025 r15 2/14/2023
Raleigh, NC 27604
Customer:
Analysis ID: 71988723_PBW
Attn: Anthony Scialdone
Date Reported: 3/30/2022
Date Received: 3/30/2022
Project: Cape Hatteras Lighthouse
Lab Order ID: 71988723
Lab Notes
Description
Lab Sample ID
Sample ID
Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy
EPA SW-846 3050B/6010C/7000B
Concentration
(µg)(ft²)
Area Concentration
(µg/ft²)
71988723PBW_11
7th floor/ marble floorFL7-C 36001 3600
71988723PBW_12
8th floor/ marble floorFL8-R 51001 5100
71988723PBW_13
8th floor/ window sillWS8-R
6100.58 1000
71988723PBW_14
9th floor/ metal platformFL9-C 23001 2300
71988723PBW_15
9th floor/ window sillWS9-C 28001 2800
71988723PBW_16
10th floor/ metal platformFL10-R 30001 3000
71988723PBW_17
Blank wipeBL1 < 2.0- -
71988723PBW_18
Blank wipeBL2 < 2.0- -
Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 25ml sample is 2µg Total Pb). Unless indicated, areas and volumes were provided by the customer.
Athena Summa (18)
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Analyst Laboratory Director
Page 2 of 2pbRpt_4.0.01_pbwI_v0.2
. ·~ c~ -• ~,&J: Scientific Analytical Institute L(lb Use Only I I {)A '-..Z---1 Lab Order ID: ~ vt DI::> L
Client Code: ,,--' ·,: ..
4604 Dundas Dr. Greensboro, NC 27407 Phone: 336.292.3888 Fax: 336.292.3313
/ www.sailab.com lab@sailab.com
Contact Information -:·.,.
Company Name: Terracon Company: .
Address: 2401 Bre11twood Rd Suite 106 Address:
Raleigh, NC 27604
Contact:
Contact: Pirone 0:
Plrolle 0: Fax0:
Fax0: Email 0:
Email IBf:
PO Number:
Lead Test T _. -es ...... · .... 12 Hours Paint Chips by Flame AA O Soil by Flame AA 0 (PBP (PBS Other D 24 Hours
Wipe by Flame AA i8J. Air by Flame AA 0 (PBW) (PBA 48 Hours
.L
• 120 Hours
• 144+ Hours
01 02
03 04
05 06
07 08
09 10
11 12
13 14
P (919) 873-2211 Terracon.com
April 20, 2022
Heritage Contracting 201 Dexter Street West, Suite 104 Chesapeake, Virginia 23324
Attn: Eric Dryfka P: (757) 472-4630 E: edryfka@heritage-contracting.com
Re: Limited Lead Wipe Sampling Report – First Cleaning Sampling Cape Hatteras Lighthouse 46379 Lighthouse Road Buxton, North Carolina 27920 Terracon Project No.: 70227071
Dear Mr. Dryfka:
Terracon Consultants, Inc. (Terracon) is pleased to present the results of the limited lead wipe sampling event performed at the Cape Hatteras Lighthouse located in Buxton, North Carolina. This sampling was conducted after the first cleaning event on April 1, 2022, in general accordance with Terracon proposal P70227071, dated February 3, 2022.
PROJECT INFORMATION
Terracon previously provided lead consulting services at the lighthouse as part of the National Park Service (NPS) restoration project for QuinnEvans. U.S. National Park Services (NPS) representatives requested that Heritage conduct additional cleaning inside the lighthouse in an attempt to reduce lead dust levels on the floors and windows sills below the current Environmental Protection Agency (EPA) and Housing and Urban Development (HUD) lead dust standards.
The current scope of work is to perform additional lead wipe sampling before the first cleaning event (background) and after each of the three planned cleaning events, for a total of four sampling events.
The scope of services was limited to collecting lead wipe samples in the lighthouse and reporting the laboratory results.
SAMPLING AND ANALYSIS METHODS
Terracon collected 18 lead wipe samples from surfaces throughout the lighthouse following a first round of additional cleaning activities. The lead wipe sampling was conducted by Terracon representative, Christian Borrel. The sample locations were selected at the discretion of Terracon’s representative or at the direction of the Heritage Contracting representative present at the time of the sampling.
The samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker and submitted for analysis under a chain of custody to Scientific Analytical Institute, Limited Lead Wipe Sampling Report – First Cleaning Sampling
46379 Lighthouse Road ■ Buxton, North Carolina April 20, 2022 ■ Terracon Project No. 70227071
Association (AIHA®) Environmental Lead Proficiency Analytical Testing Program (ELPAT No. 173190) for lead laboratory analysis.
RESULTS
Lead was detected in the ten interior floor wipe samples collected in concentrations between 43 micrograms per square foot (µg/ft2) and 680 µg/ft2. Lead was detected in the five window sill wipe samples collected in concentrations between 290 µg/ft2 and 810 µg/ft2. In addition, the wipe sample collected from the exterior granite entry landing had lead detected in a concentration of 450 µg/ft2.
The two quality control samples had no detectable lead concentration.
Based on these results, the surfaces tested had levels of lead above the respective current Environmental Protection Agency (EPA) and Housing and Urban Development (HUD) lead dust clearance standards of 10 µg/ft2 for floors, 100 µg/ft2 for window sills, and 40 µg/ft2 for porches (the nearest comparable standard for the exterior sample). The lead wipe sampling data form and laboratory analytical results follow as attachments to this report.
LIMITATIONS
The limited lead wipe sampling was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, and/or conclusions expressed in the report are based on conditions observed during the lead wipe sampling event. This report has been prepared on behalf of and exclusively for use and reliance by Heritage Contracting. This report is not a bidding document.
Contractors or consultants reviewing this lead wipe sampling report must draw their own conclusions regarding further investigation or abatement deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information that may have been used in preparation of this report. No warranty, express or implied, is made.
Terracon appreciates the opportunity to provide lead wipe sampling services to you. If you have any questions regarding the content of this report, or if we can be of further assistance, please contact us at
(919) 873-2211.
Sincerely, Terracon Consultants, Inc.
For Alicia Coley, CIH Russell Harrings, CIH Project Industrial Hygienist Authorized Project Reviewer
Sampling performed on 04/01/2022 following the First Cleaning Event
Cape Hatteras Lighthouse 46379 Lighthouse Road
Buxton, North Carolina 27920 Terracon Project No. 70227071
Sample ID Material Description Result Unit
FLOOR WIPE SAMPLES
EXT-R Exterior – Front Entrance Granite 450 µg/ft2
FL1-C 1st Floor – Marble Floor 130 µg/ft2
FL2-R 2nd Floor – Marble Floor 53 µg/ft2
FL3-C 3rd Floor – Marble Floor 43 µg/ft2
FL4-R 4th Floor – Marble Floor 97 µg/ft2
FL5-C 5th Floor – Marble Floor 110 µg/ft2
FL6-R 6th Floor – Marble Floor 86 µg/ft2
FL7-C 7th Floor – Marble Floor 250 µg/ft2
FL8-R 8th Floor – Marble Floor 130 µg/ft2
FL9-C 9th Floor – Metal Floor 680 µg/ft2
FL10-R 10th Floor – Metal Floor 630 µg/ft2
WINDOW SILL WIPE SAMPLES
WS3-R 3rd Floor – Window Sill 810 µg/ft2
WS5-R 5th Floor – Window Sill 640 µg/ft2
WS6-C 6th Floor – Window Sill 290 µg/ft2
WS7-R 7th Floor – Window Sill 680 µg/ft2
WS9-C 9th Floor – Window Sill 380 µg/ft2
Raleigh, NC 27604
Customer:
Analysis ID: 71989081_PBW
Attn: Anthony Scialdone
Date Amended: 4/6/2022
Date Reported: 4/4/2022
Date Received: 4/4/2022
Project: Cape Hatteras Lighthouse
Lab Order ID: 71989081
Lab Notes
Description
Lab Sample ID
Sample ID
Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy
EPA SW-846 3050B/6010C/7000B
Concentration
(µg)(ft²)
Area Concentration
(µg/ft²)
71989081PBW_1
Exterior/ lh entrance/ graniteEXT-R 4501 450
71989081PBW_2
Interior/ 1st floor/ marble tileFL1-C 1301 130
71989081PBW_3
2nd floor/ marble tileFL2-R 531 53
71989081PBW_4
3rd Floor/ marble tileFL3-C 431 43
71989081PBW_5
3rd Floor / window sill / metalWS3-R
4700.58 810
71989081PBW_6
4th Floor/ marble tileFL4-R 971 97
71989081PBW_7
5th Floor/ marble tileFL5-C 1101 110
71989081PBW_8
5th Floor/ window sill/ metalWS5-R
3600.57 640
71989081PBW_9
6th Floor/ marble tileFL-6 861 86
71989081PBW_10
6th Floor/ window sill/ metalWS6-C
1800.62 290
Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 25ml sample is 2µg Total Pb). Unless indicated, areas and volumes were provided by the customer.
Athena Summa (18)
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Analyst Laboratory Director
Raleigh, NC 27604
Customer:
Analysis ID: 71989081_PBW
Attn: Anthony Scialdone
Date Amended: 4/6/2022
Date Reported: 4/4/2022
Date Received: 4/4/2022
Project: Cape Hatteras Lighthouse
Lab Order ID: 71989081
Lab Notes
Description
Lab Sample ID
Sample ID
Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy
EPA SW-846 3050B/6010C/7000B
Concentration
(µg)(ft²)
Area Concentration
(µg/ft²)
71989081PBW_11
7th Floor/ marble tileFL7-C 2501 250
71989081PBW_12
7th Floor/ window sill/ metalWS7-R
4300.63 680
71989081PBW_13
8th Floor/ marble tileFL8-R 1301 130
71989081PBW_14
9th floor/ metal platformFL9-C 6801 680
71989081PBW_15
9th Floor/ window sill/ metalWS9-C 3801 380
71989081PBW_16
10th Floor/ metal platformFL10-R 6301 630
71989081PBW_17
Blank wipeBL1 < 2.0- -
71989081PBW_18
Blank wipeBL2 < 2.0- -
Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 25ml sample is 2µg Total Pb). Unless indicated, areas and volumes were provided by the customer.
Athena Summa (18)
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Analyst Laboratory Director lA'.J
Scientific Analytical Institute Lab Use Only 1 \ f'-A c / q O r/1 Lab Order ID: -'-. _v_L~---~- I
4604 Dundas Dr. Greensboro, NC 27407 Phone: 336.292.3888 Fax: 336.292.3313 Client Code: _____ _
/ www.sailab.com lab@sailab.com
Contaet Informatio,n Compa1iy Name: Terracon
Address: 2401 Brentwood Rd Suite 106
Raleigh, NC 27604
Contact:
Pliolle 0:
Fax0:
Lead Te-st T .. , es Paint Chips by Flame AA O Soil by Flame AA
(PBP PBS
Wipe by Flame AA
(PBW
Air by Flame AA 0
(PBA
Other D
Company: .
Address:
Contact:
Phone 0:
Fax0:
Email 0:
:,-~n;~ o, --",-ta; Tfnf "i _, ~T '..,_ ,• ,-.;:;._ ,.-_-• • ""_,,,, .... __ ~' ~~:'-._ ~ ...,_ ,,,..,__ ... ,!ffi~< ,_ .; -- 3 Hours □ 72 Hours
6 Hours IX' 96 Hours
12 Hours □ 120 Hours
24 Hours □ 144+ Hours
48 Hours □
EXT-R FL1-C
FL2-R FL3-C
WS3-R FL4-R
FL5-C WS5-R
FL6-R WS6-C
FL7-C WS7-R
FL8-R FL9-C
WS9-C FL10-R
P (919) 873-2211 Terracon.com
April 20, 2022
Heritage Contracting 201 Dexter Street West, Suite 104 Chesapeake, Virginia 23324
Attn: Eric Dryfka P: (757) 472-4630 E: edryfka@heritage-contracting.com
Re: Limited Lead Wipe Sampling Report – Second Cleaning Sampling Cape Hatteras Lighthouse 46379 Lighthouse Road Buxton, North Carolina 27920 Terracon Project No.: 70227071
Dear Mr. Dryfka:
Terracon Consultants, Inc. (Terracon) is pleased to present the results of the limited lead wipe sampling event performed at the Cape Hatteras Lighthouse located in Buxton, North Carolina. This sampling was conducted after the second cleaning event on April 8, 2022, in general accordance with Terracon proposal P70227071, dated February 3, 2022.
PROJECT INFORMATION
Terracon previously provided lead consulting services at the lighthouse as part of the National Park Service (NPS) restoration project for QuinnEvans. U.S. National Park Services (NPS) representatives requested that Heritage conduct additional cleaning inside the lighthouse in an attempt to reduce lead dust levels on the floors and windows sills below the current Environmental Protection Agency (EPA) and Housing and Urban Development (HUD) lead dust standards.
The current scope of work is to perform additional lead wipe sampling before the first cleaning event (background) and after each of the three planned cleaning events, for a total of four sampling events.
The scope of services was limited to collecting lead wipe samples in the lighthouse and reporting the laboratory results.
SAMPLING AND ANALYSIS METHODS
Terracon collected 18 lead wipe samples from surfaces throughout the lighthouse following a second round of additional cleaning activities. The lead wipe sampling was conducted by Terracon representative, Christian Borrel. The sample locations were selected at the discretion of Terracon’s representative or at the direction of the Heritage Contracting representative present at the time of the sampling.
The samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker and submitted for analysis under a chain of custody to Scientific Analytical Institute, Limited Lead Wipe Sampling Report – Second Cleaning Sampling
46379 Lighthouse Road ■ Buxton, North Carolina April 20, 2022 ■ Terracon Project No. 70227071 under method SW846-3050B/6010C/7000B. SAI is accredited by the American Industrial Hygiene Association (AIHA®) Environmental Lead Proficiency Analytical Testing Program (ELPAT No. 173190) for lead laboratory analysis.
RESULTS
Lead was detected in the ten interior floor wipe samples collected in concentrations between 23 micrograms per square foot (µg/ft2) and 240 µg/ft2. Lead was detected in the five window sill wipe samples collected in concentrations between 100 µg/ft2 and 240 µg/ft2. In addition, the wipe sample collected from the exterior granite entry landing had lead detected in a concentration of 39 µg/ft2.
The two quality control samples had no detectable lead concentration.
Based on these results, most of the surfaces tested had levels of lead still above the respective current Environmental Protection Agency (EPA) and Housing and Urban Development (HUD) lead dust clearance standards of 10 µg/ft2 for floors, 100 µg/ft2 for window sills, and 40 µg/ft2 for porches (the nearest comparable standard for the exterior sample). The exterior front entrance sample (39 µg/ft2) and the 9th floor window sill sample (100 µg/ft2) had concentrations at or below the clearance thresholds. The lead wipe sampling data form and laboratory analytical results follow as attachments to this report.
LIMITATIONS
The limited lead wipe sampling was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, and/or conclusions expressed in the report are based on conditions observed during the lead wipe sampling event. This report has been prepared on behalf of and exclusively for use and reliance by Heritage Contracting. This report is not a bidding document.
Contractors or consultants reviewing this lead wipe sampling report must draw their own conclusions regarding further investigation or abatement deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information that may have been used in preparation of this report. No warranty, express or implied, is made.
Terracon appreciates the opportunity to provide lead wipe sampling services to you. If you have any questions regarding the content of this report, or if we can be of further assistance, please contact us at
(919) 873-2211.
Sincerely, Terracon Consultants, Inc.
For Alicia Coley, CIH Russell Harrings, CIH Project Industrial Hygienist Authorized Project Reviewer
Sampling performed on 04/08/2022 following the Second Cleaning Event
Cape Hatteras Lighthouse 46379 Lighthouse Road
Buxton, North Carolina 27920 Terracon Project No. 70227071
Sample ID Material Description Result Unit
FLOOR WIPE SAMPLES
EXT-R Exterior – Front Entrance Granite 39 µg/ft2
FL1-C 1st Floor – Marble Floor 130 µg/ft2
FL2-R 2nd Floor – Marble Floor 31 µg/ft2
FL3-C 3rd Floor – Marble Floor 23 µg/ft2
FL4-R 4th Floor – Marble Floor 40 µg/ft2
FL5-C 5th Floor – Marble Floor 35 µg/ft2
FL6-R 6th Floor – Marble Floor 240 µg/ft2
FL7-C 7th Floor – Marble Floor 93 µg/ft2
FL8-R 8th Floor – Marble Floor 44 µg/ft2
FL9-C 9th Floor – Metal Floor 60 µg/ft2
FL10-R 10th Floor – Metal Floor 61 µg/ft2
WINDOW SILL WIPE SAMPLES
WS2-R 2nd Floor – Window Sill 150 µg/ft2
WS4-R 4th Floor – Window Sill 210 µg/ft2
WS6-C 6th Floor – Window Sill 150 µg/ft2
WS8-R 8th Floor – Window Sill 240 µg/ft2
WS9-C 9th Floor – Window Sill 100 µg/ft2
Raleigh, NC 27604
Customer:
Analysis ID: 71989627_PBW
Attn: Anthony Scialdone
Date Reported: 4/11/2022
Date Received: 4/11/2022
Project: Cape Hatteras Lighthouse
Lab Order ID: 71989627
Lab Notes
Description
Lab Sample ID
Sample ID
Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy
EPA SW-846 3050B/6010C/7000B
Concentration
(µg)(ft²)
Area Concentration
(µg/ft²)
71989627PBW_1
Exterior/entrance/stoneEXT-R 391 39
71989627PBW_2
1st floor/floor/marbleFL1-C 1301 130
71989627PBW_3
2nd floor/floor/marbleFL2-R 311 31
71989627PBW_4
2nd floor/window sill/metalWS2-R
930.64 150
71989627PBW_5
3rd floor/floor/marbleFL3-C 231 23
71989627PBW_6
4th floor/floor/marbleFL4-R
40.1 40.
71989627PBW_7
4th floor/window sill/metalWS4-R
1400.68 210
71989627PBW_8
5th floor/floor/marbleFL5-C 351 35
71989627PBW_9
6th floor/floor/marbleFL6-R 2401 240
71989627PBW_10
6th floor/window sill/metalWS6-C
1000.67 150
Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 25ml sample is 2µg Total Pb). Unless indicated, areas and volumes were provided by the customer.
Xaviera Watkins (18)
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Analyst Laboratory Director
Raleigh, NC 27604
Customer:
Analysis ID: 71989627_PBW
Attn: Anthony Scialdone
Date Reported: 4/11/2022
Date Received: 4/11/2022
Project: Cape Hatteras Lighthouse
Lab Order ID: 71989627
Lab Notes
Description
Lab Sample ID
Sample ID
Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy
EPA SW-846 3050B/6010C/7000B
Concentration
(µg)(ft²)
Area Concentration
(µg/ft²)
71989627PBW_11
7th floor/floor/marbleFL7-C 931 93
71989627PBW_12
8th floor/floor/marbleFL8-R 441 44
71989627PBW_13
8th floor/window sill/marbleWS8-R
1600.68 240
71989627PBW_14
9th floor/floor/marbleFL9-C
60.1 60.
71989627PBW_15
9th floor/window sill/metalWS9-C 1001 100
71989627PBW_16
10th floor/floor/marbleFL10-R 611 61
71989627PBW_17
BlankBL1 < 2.0- -
71989627PBW_18
BlankBL2 < 2.0- -
Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 25ml sample is 2µg Total Pb). Unless indicated, areas and volumes were provided by the customer.
Xaviera Watkins (18)
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Analyst Laboratory Director
EXT R - R FLR 1 - C
WS – 2 R FLR 2 -R
FLR – 3 C FLR – 4 R
WS – 4 R FLR – 5 C
FLR – 6 R WS – 6 C
FLR 7 - C FLR 8 - R
WS – 8 R FLR – 9 C
WS – 9 C FLR 10 – R
P (919) 873-2211 Terracon.com
April 21, 2022
Heritage Contracting 201 Dexter Street West, Suite 104 Chesapeake, Virginia 23324
Attn: Eric Dryfka P: (757) 472-4630 E: edryfka@heritage-contracting.com
Re: Limited Lead Wipe Sampling Report – Third Cleaning Sampling Cape Hatteras Lighthouse 46379 Lighthouse Road Buxton, North Carolina 27920 Terracon Project No.: 70227071
Dear Mr. Dryfka:
Terracon Consultants, Inc. (Terracon) is pleased to present the results of the limited lead wipe sampling event performed at the Cape Hatteras Lighthouse located in Buxton, North Carolina. This sampling was conducted after the third cleaning event on April 14, 2022, in general accordance with Terracon proposal P70227071, dated February 3, 2022.
PROJECT INFORMATION
Terracon previously provided lead consulting services at the lighthouse as part of the National Park Service (NPS) restoration project for Quinn Evans. U.S. National Park Services (NPS) representatives requested that Heritage conduct additional cleaning inside the lighthouse in an attempt to reduce lead dust levels on the floors and windows sills below the current Environmental Protection Agency (EPA) and Housing and Urban Development (HUD) lead dust standards.
The current scope of work is to perform additional lead wipe sampling before the first cleaning event (background) and after each of the three planned cleaning events, for a total of four sampling events.
The scope of services was limited to collecting lead wipe samples in the lighthouse and reporting the laboratory results.
SAMPLING AND ANALYSIS METHODS
Terracon collected 18 lead wipe samples from surfaces throughout the lighthouse following a third round of additional cleaning activities. The lead wipe sampling was conducted by Terracon representative, Christian Borrel. The sample locations were selected at the discretion of Terracon’s representative or at the direction of the Heritage Contracting representative present at the time of the sampling.
The samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker and submitted for analysis under a chain of custody to Scientific Analytical Institute, Limited Lead Wipe Sampling Report – Third Cleaning Sampling
46379 Lighthouse Road ■ Buxton, North Carolina April 21, 2022 ■ Terracon Project No. 70227071
Association (AIHA®) Environmental Lead Proficiency Analytical Testing Program (ELPAT No. 173190) for lead laboratory analysis.
RESULTS
Lead was detected in the ten interior floor wipe samples collected in concentrations between 21 micrograms per square foot (µg/ft2) and 160 µg/ft2. Lead was detected in the five window sill wipe samples collected in concentrations between 86 µg/ft2 and 490 µg/ft2. In addition, the wipe sample collected from the exterior granite entry landing had lead detected in a concentration of 230 µg/ft2.
The two quality control samples had no detectable lead concentration.
Based on these results, most of the surfaces tested, except one surface, had levels of lead still above the respective current Environmental Protection Agency (EPA) and Housing and Urban Development (HUD) lead dust clearance standards of 10 µg/ft2 for floors, 100 µg/ft2 for window sills, and 40 µg/ft2 for porches (the nearest comparable standard for the exterior sample). The 6th floor window sill sample (86 µg/ft2) had a lead concentration below the clearance threshold. The lead wipe sampling data form and laboratory analytical results follow as attachments to this report.
LIMITATIONS
The limited lead wipe sampling was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, and/or conclusions expressed in the report are based on conditions observed during the lead wipe sampling event. This report has been prepared on behalf of and exclusively for use and reliance by Heritage Contracting. This report is not a bidding document.
Contractors or consultants reviewing this lead wipe sampling report must draw their own conclusions regarding further investigation or abatement deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information that may have been used in preparation of this report. No warranty, express or implied, is made.
Terracon appreciates the opportunity to provide lead wipe sampling services to you. If you have any questions regarding the content of this report, or if we can be of further assistance, please contact us at
(919) 873-2211.
Sincerely, Terracon Consultants, Inc.
For Alicia Coley, CIH Russell Harrings, CIH Project Industrial Hygienist Authorized Project Reviewer
Sampling performed on 04/14/2022 following the Third Cleaning Event
Cape Hatteras Lighthouse 46379 Lighthouse Road
Buxton, North Carolina 27920 Terracon Project No. 70227071
Sample ID Material Description Result Unit
FLOOR WIPE SAMPLES
EXT-R Exterior – Front Entrance Stone 230 µg/ft2
FL1-C 1st Floor – Marble Floor 37 µg/ft2
FL2-R 2nd Floor – Marble Floor 28 µg/ft2
FL3-C 3rd Floor – Marble Floor 21 µg/ft2
FL4-R 4th Floor – Marble Floor 24 µg/ft2
FL5-C 5th Floor – Marble Floor 23 µg/ft2
FL6-R 6th Floor – Marble Floor 21 µg/ft2
FL7-C 7th Floor – Marble Floor 55 µg/ft2
FL8-R 8th Floor – Marble Floor 34 µg/ft2
FL9-C 9th Floor – Metal Floor 60 µg/ft2
FL10-R 10th Floor – Metal Floor 160 µg/ft2
WINDOW SILL WIPE SAMPLES
WS2-R 2nd Floor – Window Sill 140 µg/ft2
WS5-R 5th Floor – Window Sill 370 µg/ft2
WS6-C 6th Floor – Window Sill 86 µg/ft2
WS7-R 7th Floor – Window Sill 490 µg/ft2
WS9-C 9th Floor – Window Sill 150 µg/ft2
Raleigh, NC 27604
Customer:
Analysis ID: 71990011_PBW
Attn: Anthony Scialdone
Date Reported: 4/15/2022
Date Received: 4/15/2022
Project: Cape Hatteras Lighthouse (4th sampling)
Lab Order ID: 71990011
Lab Notes
Description
Lab Sample ID
Sample ID
Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy
EPA SW-846 3050B/6010C/7000B
Concentration
(µg)(ft²)
Area Concentration
(µg/ft²)
71990011PBW_1
Exterior/Porch/StoneEXT-R 2301 230
71990011PBW_2
1st Floor/Floor/MarbleFL1-C 371 37
71990011PBW_3
2nd Floor/Floor/MarbleFL2-R 281 28
71990011PBW_4
2nd Floor/Window sill/MetalWS2-R
950.68 140
71990011PBW_5
3rd Floor/Floor/MarbleFL3-C 211 21
71990011PBW_6
4th Floor/Floor/MarbleFL4-R 241 24
71990011PBW_7
5th Floor/Floor/MarbleFL5-C 231 23
71990011PBW_8
5th Floor/Window sill/MetalWS5-R
2300.64 370
71990011PBW_9
6th Floor/Floor/MarbleFL6-R 211 21
71990011PBW_10
6th Floor/Window sill/MetalWS6-C
580.68 86
Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 25ml sample is 2µg Total Pb). Unless indicated, areas and volumes were provided by the customer.
Athena Summa (18)
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Analyst Laboratory Director
Raleigh, NC 27604
Customer:
Analysis ID: 71990011_PBW
Attn: Anthony Scialdone
Date Reported: 4/15/2022
Date Received: 4/15/2022
Project: Cape Hatteras Lighthouse (4th sampling)
Lab Order ID: 71990011
Lab Notes
Description
Lab Sample ID
Sample ID
Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy
EPA SW-846 3050B/6010C/7000B
Concentration
(µg)(ft²)
Area Concentration
(µg/ft²)
71990011PBW_11
7th Floor/Floor/MarbleFL7-C 551 55
71990011PBW_12
7th Floor/Window sill/MetalWS7-R
3200.65 490
71990011PBW_13
8th Floor/Floor/MarbleFL8-R 341 34
71990011PBW_14
9th Floor/Floor/MetalFL9-C
60.1 60.
71990011PBW_15
9th Floor/Window sill/MetalWS9-C 1501 150
71990011PBW_16
10th Floor/Floor/MetalFL10-R 1601 160
71990011PBW_17
BlankBL1 < 2.0- -
71990011PBW_18
BlankBL2 < 2.0- -
Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 25ml sample is 2µg Total Pb). Unless indicated, areas and volumes were provided by the customer.
Athena Summa (18)
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Analyst Laboratory Director
.-' r ,_ . ' 1it
1ki n Scientific Analytical Institute Lab Use Only 1 \ n\ °I (X)\ \
Lab Order ID:--'-l _ -_ I __ _.:.
4604 Dundas Dr. Greensboro, NC 27407 Phone: 336.292.3888 Fax: 336.292.331.3 Client Code: _____ _ www.sailab.com lab@sailab.com
ConJ:a,ct lnforl'IJation Compa11y Name: Terracon
Address: 2401 Brentwood Rd Suite 106
Raleigh, NC 27604
Contact:
Plwne 0:
Fax 0:
Email~
PO Number:
Paint Chips by Flame AA O Soil by Flame AA 0
(PBP (PBS)
Wipe by Flame AA
(PBW)
Air by Flame AA 0
(PBA
Other 0
Company: -
Address:
Contact:
P/zoneO:
Fax0:
Email 0:
3 Hours
6 Hours
12 Hours D 120 Hours
24 Hours D 144+ Hours
48 Hours •
Total Number of Samples J 6?
EXT - R FL1-C
FLR2 - R WS2-R
FLR-3 C
FLR- 4 R
FLR-5 C WS6 - C
FLR-6 R WS6-C
FLR- 7 C WS8-R
FLR-8 R FLR-9 C
FLR9-C
FLR 10-R
| Hatteras Lead Testing Summary |
| 03-28-22 Terracon Report |
| Initial Testing 3.28.22 71988723_PBW |
| Lead Testing Photos 03-28-22 |
| 04-01-22 Terracon Report |
| 2b. Amended SAI Lead Wipe Sampling Results (04.06.2022) |
| 04-01-22 Lead Testing Photos |
| 04-08-22 Terracon Report |
| 3. SAI Lead Wipe Sampling Results (04.11.2022) |
| 04-08-22 Lead Test Photos |
| 04-14-22 Terracon Report |
| 4. SAI Lead Wipe Sampling Results (04.14.2022) |
04-14-22 Lead Testing Images
File details come from the government source that posted it. Updated .