Attachment 4 - 668-14-107_Plumbing Survey_Dead Leg Summary Total .pdf

PDF 232 KB Posted

Attached to
C1DA--668-22-106 Correct Domestic Water System Deficiencies Buildings 1 and 12
Solicitation number
36C26024R0038
Issued by

About this file

This notice requests Standard Form 330 Architect-Engineer Qualifications packages for the design of a project to modify existing hot and cold potable water distribution systems in Buildings 1 and 12 at the Mann-Grandstaff VA Medical Center in Spokane, Washington. The project is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses. The design contract to be awarded has an anticipated period of performance of 315 calendar days and a magnitude of construction between $1,000,000 and $2,000,000. Statements of Qualifications are due by April 15, 2024 and are limited to 20 pages. The top three scoring firms will participate in written discussions. Evaluation criteria include professional qualifications, specialized experience and technical competence, capacity, past performance, knowledge of the locality, and experience in construction period services. The selection will prioritize these criteria and consider information provided in the SF 330 submission and discussions.

The notice provides submission requirements and the evaluation process. Firms must be certified SDVOSBs and meet NAICS code 541330. Examples of five relevant design projects must be provided, including descriptions of scope, value, and owner references. Construction completion is required for three examples. Past performance will be evaluated through CPARS and Project Performance Questionnaires. The selection is for design services and construction administration for the specified domestic water system project at the medical center.

View the file

Other files

File Type Posted
Attachment 10 - 668-16-110_Cross-Connection Evaluation Plans 1of10 .pdf PDF
Attachment 31 - VHA DIRECTIVE 1061_2021-02-16 .pdf PDF
Attachment 1 - 668-22-106_SOW_Revision 3.pdf PDF
Attachment 25 - 668-16-110_Cross-Connection Inventory Report - APPENDIX D - 1of3 .pdf PDF
Attachment 2 - 668-14-107_Plumbing Survey_FINAL DRAWINGS.pdf PDF
Attachment 3 - 668-14-107_Plumbing Survey_FINAL INVENTORY .pdf PDF
Attachment 35 - Phigenics As-Built Drawings.pdf PDF
Attachment 6 - 668-16-110_Feasibility Study_Project Manual .pdf PDF
Attachment 14 - 668-16-110_Cross-Connection Evaluation Plans 5of10 .pdf PDF
36C26024R0038_1.docx DOCX document
Attachment 28 - 668-16-110_Cross-Connection Inventory Report - APPENDIX E-F .pdf PDF
Attachment 13 - 668-16-110_Cross-Connection Evaluation Plans 4of10 .pdf PDF
Attachment 24 - 668-16-110_Cross-Connection Inventory Report - APPENDIX C .pdf PDF
Attachment 16 - 668-16-110_Cross-Connection Evaluation Plans 7of10 .pdf PDF
Attachment 18 - 668-16-110_Cross-Connection Evaluation Plans 9of10 .pdf PDF
Attachment 20 - 668-16-110_Cross-Connection Inventory Report .pdf PDF
Attachment 33 - 668-22-106_DESIGN REVIEW COMMENT SHEET.xlsx XLSX spreadsheet
Attachment 29 - 668-16-110_Cross-Connection Corrective Action Report .pdf PDF
Attachment 23 - 668-16-110_Cross-Connection Inventory Report - APPENDIX B2 .pdf PDF
Attachment 5 - 668-16-110_Feasibility Study_Drawings .pdf PDF
Attachment 7 - 668-16-110_Feasibility Study_Report .pdf PDF
Attachment 15 - 668-16-110_Cross-Connection Evaluation Plans 6of10 .pdf PDF
Attachment 8 - 668-16-110_Feasibility Study_Fixture Inventory and Tracking .pdf PDF
Attachment 19 - 668-16-110_Cross-Connection Evaluation Plans 10of10 .pdf PDF
Attachment 12 - 668-16-110_Cross-Connection Evaluation Plans 3of10 .pdf PDF
Attachment 17 - 668-16-110_Cross-Connection Evaluation Plans 8of10 .pdf PDF
Attachment 9 - 668-16-110_Feasibility Study_Cost Estimate .pdf PDF
Attachment 27 - 668-16-110_Cross-Connection Inventory Report - APPENDIX D - 3of3 .pdf PDF
Attachment 22 - 668-16-110_Cross-Connection Inventory Report - APPENDIX B1 .pdf PDF
Attachment 26 - 668-16-110_Cross-Connection Inventory Report - APPENDIX D - 2of3.pdf PDF
Attachment 11 - 668-16-110_Cross-Connection Evaluation Plans 2of10 .pdf PDF
Attachment 32 - MGVMAC_Design Amendments_May 2021 .pdf PDF
Attachment 36 - PPQ.docx DOCX document
Attachment 34 - 2020 GAO High Quality Project Estimate Characteristics .xlsx XLSX spreadsheet
Attachment 30 - 668-16-110_Cross-Connection Control Plan FINAL .pdf PDF
Attachment 21 - 668-16-110_Cross-Connection Inventory Report - APPENDIX A .pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Building 2 Building

Building

Building

Building

Building

Utility Plant -

Laundry

Community

Living Center

Outpatient

Clinic Eye Clinic

Physical - O.T.

Prosthetics Dental Clinic Basement 1st Floor 2nd Floor 3rd Floor 4th Floor 5th Floor 6th Floor 7th Floor 8th Floor 9th Floor 10th Floor

TOTALS BY TYPES OF

DEAD LEGS

Type Description

1 Pipe lengths greater than 10 feet terminating at a cap. 0 1 0 1 3 0 6 3 9 2 0 3 0 2 0 0 0 30

2 Pipe lengths greater than 10 feet terminating at a closed valve. 1 5 3 4 1 1 0 0 0 0 0 0 0 0 0 0 0 15

3 Pipe lengths greater than 10 feet terminating at a fitting. 0 0 0 0 0 0 4 0 1 0 0 0 0 0 1 2 0 8

Pipe lengths greater than 10 feet terminating at an infrequently used plumbing fixture. An infrequently used plumbing fixture is a fixture where the hot water line or cold water line is run less than once each day.

2 6 0 0 1 0 2 0 1 0 19 15 0 0 0 0 0 46

Pipe lengths greater than 25 feet terminating at a frequently used plumbing fixture.

A frequently used plumbing fixture is a fixture where both the hot water line and cold water line are run at least once each day.

1 1 4 1 1 3 6 2 5 3 6 6 3 4 1 1 0 48

TOTALS BY BUILDING/FLOOR 4 13 7 6 6 4 18 5 16 5 25 24 3 6 2 3 0 147

Building 1 - Main Hospital

DEAD LEG SUMMARY TOTAL FOR ALL BUILDINGS

VA Spokane Legionella Hot and Cold Water System As-Built

Project 668-14-107

April 30, 2016