About this file
These drawings are construction documents for replacing Building 121 at the Michael E. Debakey VA Medical Center in Houston, Texas. The project involves constructing a new 14,977 square foot single-story Psychosocial Rehabilitation and Recovery Center (PRRC), which will include office/treatment rooms, group rooms, Occupational Therapy spaces, and support areas. The architectural drawings detail a comprehensive design with multiple office and consultation rooms, community spaces, mechanical and electrical rooms, corridors, and support facilities, with specific attention to accessibility, fire safety, and standard mounting heights for fixtures and equipment.
The technical drawings provide extensive details across multiple disciplines including architectural, structural, mechanical, electrical, plumbing, fire suppression, and technology systems. The project includes site work such as new concrete sidewalks, entrance drives, and a chiller pad, with the building featuring metal stud walls, polyiso insulation, TPO roofing, EIFS cladding, metal panels, and burnished block exterior. The drawings are prepared by Ballard CLC, Inc. for the VA Office of Construction and Facilities Management, with Apogee Consulting Group as consultants, and are part of VA Project #580-324 located at 2002 Holcombe Boulevard in Houston, Texas.
View the file
Other files for this federal contract opportunity
Show all 36
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BID DEDUCT ALTERNATES
1 ALTERNATE NO.1: BASE BID except Perform
OPEN CUT TRENCHING instead of directional boring for all utilities. See Civil Drawings. See Sheet CT-102.
2 ALTERNATE NO.2: (includes all previous alternate(s)) Delete the movable partition and supporting structure between Group Rooms. See Architectural & Structural Drawings. See Sheets A-101, & S-102.
3 ALTERNATE NO.3: (includes all previous alternate(s))Delete landscaping Trees/Shrubs, ½ of the sidewalks, and the benches. See Landscape and Civil Drawings. See Sheet CA100, CS101, CS102 &
LP101.
4 ALTERNATE NO.4: (includes all previous alternate(s)) Consolidate electrical panels to reduce the number of panels into fewer larger panels. See Electrical Drawings.
5 ALTERNATE NO.5: (includes all previous alternate(s)) Delete one of the exterior entry doors on the South side of the Entry Vestibule. See Architectural Drawings. See sheets A-101, & A-201
6 ALTERNATE NO.6: (includes all previous alternate(s)) Reduce the Amount of Tile areas in the Restrooms on the walls to a wainscot 52” tall on two walls only (behind the sinks and by the toilets).
7 ALTERNATE NO.7: (includes all previous alternate(s)) Delete Main Entry Vestibule in it’s entirety on the exterior of the building. Provide a new vestibule inside the building as part of the Waiting area. See Architectural & Structural Drawings. See sheets A-101, A-201, A311, A-312, S-100, & S-102.
8 ALTERNATE NO.8: (includes all previous alternate(s)) Delete Metal Siding and replace with EIFS in the same configuration. See Architectural Drawings. See sheet A-201 & A-311.
9 ALTERNATE NO.9: (includes all previous alternate(s)) Reduce height of Burnished Block Masonry to the height of the bottom of the windows and replace with EIFS. See Architectural Drawings. See sheets A-201, & A-311.
10 ALTERNATE NO.10: (includes all previous alternate(s)) Delete Wood Plank Ceiling in Waiting Lobby and replace with suspended acoustic ceiling tiles (2x2). See Architectural Drawings. See sheet A-110.
11 ALTERNATE NO.11: (includes all previous alternate(s)) Delete Terrazzo Floor Tiles and replace with LVT. See Interior Drawings. See Sheet I-121.
12 ALTERNATE NO.12: NOT USED.
13 ALTERNATE NO.13: (includes all previous alternate(s)) Delete raised entry lobby roof/ceiling, omit all clearstory windows, and lower the top of the large exterior storefront window in the Lobby/waiting area. Reduce HVAC for this area reduction. See Architectural, Structural, & Mechanical Drawings. See sheets A-201, A-311, S-102, S-103, MH101.
14 ALTERNATE NO.14: (includes all previous alternate(s)) Provide shell spaces for 16 Office/Consult Rooms and Break Room. See Architectural Drawings. Sheet A-101.
Engineers Architects Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: ARCHITECT/ENGINEER OF RECORD
Date Checked Drawn
FULLY SPRINKLERED
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
PROJECT SITE MAP PROJECT LOCATION MAP
PROJECT IMAGE
1/
/2
3:
:1
PM
Au to de sk
D oc s:
//H ou st on V
A M ed ic al C en te r/A _2
2-
1-
BC
LC
V
A-
BL
D G
_S H
EL
L.
rv t
G-001
COVER
1 3OKM
REPLACE BUILDING 121
MICHAEL E. DEBAKEY VAMC
2002 HOLCOMBE BOULEVARD
HOUSTON, TX 77030 JANUARY 24, 2025
100% CONSTRUCTION DOCUMENTS
580-324
REPLACE BUILDING 121
MICHAEL E. DEBAKEY VAMC
2002 HOLCOMBE BOULEVARD
HOUSTON, TX 77030
VA PROJECT #: 580-324
RMC
DRAWING LIST
GENERAL
G-001 COVER
G-002 GENERAL INFORMATION
G-003 LIFE SAFETY
CIVIL
C-100 GENERAL CIVIL NOTES
C-101 OVERALL TOPOGRAPHIC SURVEY
CD-101 DEMOLITION PLAN
CG-101 GRADING PLAN
CJ-101 EROSION CONTROL PLAN
CS-101 SITE LAYOUT PLAN
CS-102 ENLARGED SITE PLAN
CT-101 PAVEMENT DETAILS
CT-102 STORM DRAINAGE DETAILS
CT-103 WATERLINE DETAILS
CT-104 SANITARY SEWER DETAILS
CT-105 THRUST BLOCKING DETAILS
CT-106 EROSION CONTROL DETAILS
CT-107 HANDICAP AND PARKING DETAILS
CU-101 SITE UTILITY PLAN
CX-100 SITE LAYOUT PLAN DEDUCTIVE ALTERNATE
LANDSCAPE
LP101 LANDSCAPE PLAN
LP501 LANDSCAPE DETAILS
STRUCTURAL
S-001 GENERAL NOTES
S-100 FOUNDATION PLAN
S-102 ROOF FRAMING PLAN
S-103 HIGH ROOF FRAMING PLAN
S-104 DEDUCT ALTERNATES - FOUNDATION & ROOF FRAMING PLANS
S-301 FOUNDATION DETAILS
S-401 MASONRY DETAILS
S-501 STEEL FRAMING DETAILS
S-502 STEEL FRAMING DETAILS
ARCHITECTURAL
AS101 SITE PLAN
A-001 ARCHITECTURAL SYMBOLS, ABBREVIATIONS AND NOTES
A-101 FLOOR PLAN
A-102 DIMENSION PLAN
A-103 ROOF PLAN
A-104 ROOF DETAILS
A-110 REFLECTED CEILING PLAN
A-111 CEILING DETAILS
A-112 CEILING DETAILS
A-201 EXTERIOR ELEVATIONS
A-301 BUILDING SECTIONS
A-302 WALL SECTIONS - EIFS
A-303 WALL SECTIONS - METAL PANEL
A-304 WALL SECTIONS - METAL PANEL
A-305 WALL DETAILS - EIFS
A-306 WALL DETAILS - METAL PANEL
A-307 COLUMN DETAILS
A-308 COLUMN DETAILS
A-309 METAL STUD DETAILS
A-310 MISCELLANEOUS DETAILS
A-310B DUMPSTER DETAILS
A-311 DEDUCT ALTERNATES - ELEVATIONS
A-312 DEDUCT ALTERNATES - FLOOR & ROOF PLANS
A-501 PARTITION TYPES
A-601 DOOR AND WINDOW SCHEDULE, ELEVATIONS AND DETAILS
INTERIORS
I-001 GENERAL NOTES, ABBREVIATIONS AND ROOM FINISH SCHEDULE
I-101 FIRST FLOOR FINISH AND WALL PROTECTION PLAN
I-141 FIRST FLOOR SIGNAGE PLAN
I-201 CASEWORK AND MILLWORK ELEVATIONS
I-202 CASEWORK AND MILLWORK ELEVATIONS
I-203 CASEWORK DETAILS
I-401 INTERIOR ELEVATIONS - WALL PROTECTION
I-402 INTERIOR ELEVATIONS - EQUIPMENT
I-411 FIRST FLOOR OVERALL EQUIPMENT PLAN
I-421 ENLARGED EQUIPMENT PLANS
I-422 ENLARGED EQUIPMENT PLANS
I-423 ENLARGED EQUIPMENT PLANS
I-424 ENLARGED EQUIPMENT PLANS
I-431 ENLARGED TOILET PLANS AND ELEVATIONS
I-432 ENLARGED TOILET PLANS AND ELEVATIONS
I-501 INTERIOR DETAILS
I-601 EQUIPMENT SCHEDULE
I-901 AXONOMETRIC VIEWS
I-902 AXONOMETRIC VIEWS
I-903 AXONOMETRIC VIEWS
FIRE SUPPRESSION
FX001 FIRE SUPPRESSION GENERAL INFORMATION
FX101 FIRST FLOOR FIRE SUPPRESSION PLAN
FX102 FIRST FLOOR FIRE SUPPRESSION REFLECTED CEILING PLAN
PLUMBING
P-001 PLUMBING GENERAL INFORMATION
PW101 FIRST FLOOR DRAIN, WASTE, AND VENT PLAN
PP101 FIRST FLOOR DOMESTIC WATER PLAN
PP102 ROOF DRAINAGE PLAN
P-401 ENLARGED PLUMBING PLANS
P-501 PLUMBING DETAILS
P-502 PLUMBING DETAILS
P-601 PLUMBING SCHEDULES
P-901 SANITARY PIPE RISERS
P-902 DOMESTIC WATER PIPE RISERS
P-903 STORM PIPE RISERS
BLDG 121
BLDG 121
DRAWING LIST
MECHANICAL
M-001 MECHANICAL GENERAL INFORMATION
MH101 FIRST FLOOR HVAC PLAN
MP101 FIRST FLOOR MECHANICAL PIPING PLAN
M-401 ENLARGED MECHANICAL PLANS
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-503 MECHANICAL DETAILS
M-504 MECHANICAL CONTROLS
M-505 MECHANICAL CONTROLS
M-506 MECHANICAL CONTROLS
M-601 MECHANICAL SCHEDULES
M-602 MECHANICAL SCHEDULES
ELECTRICAL
E-001 ELECTRICAL GENERAL NOTES, SYMBOL LEGENDS, AND ABBREVIATIONS
ES101 ELECTRICAL SITE PLAN
EP101 FIRST FLOOR POWER PLAN
EM101 FIRST FLOOR MECHANICAL POWER PLAN
EL101 FIRST FLOOR LIGHTING PLAN
E-401 ELECTRICAL ENLARGEMENTS
E-501 ELECTRICAL DETAILS
E-502 ELECTRICAL DETAILS
E-601 SINGLE LINE DIAGRAM
E-602 ELECTRICAL SCHEDULES
E-603 ELECTRICAL SCHEDULES
TECHNOLOGY
T-001 TECHNOLOGY GENERAL NOTES, SYMBOL LEGEND, AND ABBREVIATIONS
T-101 FIRST FLOOR TECHNOLOGY PLAN
T-501 TECHNOLOGY DETAILS
T-502 TECHNOLOGY DETAILS
T-503 TECHNOLOGY DETAILS
T-601 TECHNOLOGY RISERS
FIRE ALARM
FA001 FIRE ALARM GENERAL NOTES, SYMBOL LEGEND, AND RISER
FA101 FIRST FLOOR FIRE ALARM PLAN
LEADERSHIP SIGNATURE BLOCK
DIRECTOR
SAFETY MANAGER
ENERGY ENGINEER
CHIEF ENGINEER
WALL SECTION
SYMBOL INTERIOR ELEVATION
SYMBOL
COLUMN GRID
ELEVATION SYMBOL
REVISION NOTE
ENLARGED DETAIL CALLOUT
ROOM DESIGNATION
SYMBOL
BREAK LINE
ROOF SLOPE
DIRECTION SYMBOL
TYPICAL GRAPHIC SCALE
DETAIL #
PAGE #
DETAIL #
PAGE #
VIEW NORTH ARROW
A8.1
EXTERIOR ELEVATION
SYMBOL
DETAIL #
PAGE #
A8.1
A8.1
A8.1
BUILDING SECTION
SYMBOL
DETAIL #
PAGE #
A8.1
A8.1
DETAIL SECTION
SYMBOL
DETAIL #
PAGE #
A8.1
WALL GRID
(REPRESENTS
FACE OF EXISTING
WALL)
XX.X
ELEVATION
0'-0"
ROOM
NAME
101A
NORTHNORTH
0 4 8 16
1-1/2"
DIAMETER
GRAB BAR
TOILET
TISSUE
DISPENSER
SANITARY
NAPKIN
DISPOSAL
TOILET
FIXTURE
TOILET
FIXTURE
TOILET
TISSUE
DISPENSER
1-1/2"
DIAMETER
GRAB BAR
EXPOSED
PLUMBING AT
BARRIER
FREE
LAVATORIES
SHALL BE
INSULATED.
LEVER OPERATING
CONTROLLED
SOAP DISPENSER
NOTE: SINKS IN COUNTERS TO BE
MOUNTED WITH RIM NO MORE
THAN 2'-10" HIGH AND WITH AT
LEAST 2'-3" KNEE CLEARANCE.
CLEAR
ACCESSIBLE TOILET TYPICAL ACCESSIBLE
CLEARANCE AT LAVATORY
TYPICAL ACCESSIBLE
LAVATORY AND MIRROR
1'-3" 1'-3"
2' -5
" M
IN
2' -1
0" M
AX
3' -4
" M
AX
4' -0
" M
AX6'
-8 " A
.F .F
1'-6"
9"
5'-0" CLEAR
3'-0" 6"
9"
3'-0"
1' -7
" 3' -0
1' -6
3'
-4
1'-0" 3'-6"
2'-4"
5'-0" CLEAR
MIN
8"
MAX
6"
M
IN9"
2' -3
" M
IN
2' -5
" M
IN
2' -1
0" M
AX
17" MIN
TYPICAL URINAL
MOUNTING
CLEAR
15"
CLEAR
15"
1' -5
"3' -8
" M
AX
TYPICAL TOILET NON-ACCESSIBLE
TOILET
TISSUE
DISPENSER
2'-9"
2' -1
0"
TOILET
FIXTURE
1'-6"
O F
R
IM
1' -3
" T O
P
FIRE ALARM
CHIME WITH
VISUAL
ALARM LIGHT
FIRE ALARM
PULL STATION
FIRE ALARM
ANNUNCIATOR
FIRE ALARM
5' -0
3' -6
7' -0
INTERCOM
STATION INTERCOM
MASTER
STATION
INTERCOM
WALL
OUTLET
INTERCOM STATION
1' -6
4'
-0
DRINKING FOUNTAIN
WHEELCHAIR ACCESSIBLE
(CANTILEVERED STYLE)
17" - 19"
8" MIN
9" MIN
6" MAX2'
-3 " M
IN
TO
P O
F
SP
O U
T 3'
M
AX
DIAPER CHANGING
STATION
2' -4
" M
IN
2' -8
" M
AX
3/
4"
TO
B
O
TT
O M
O F
R
EF
LE
C
TI
VE
SU
R
FA
C E
O F
M
IR
R O
R
WALL MOUNTED TACKBOARD
AND MARKERBOARD
6' -4
CLOCK
NURSE
CALL
DOME
LIGHT
CLOCK OUTLET
TELEVISION
OUTLET
WALL MOUNTED TV
(TV CANNOT PROTRUDE MORE THAN
4" FROM THE WALL WHEN MOUNTED AT THESE HEIGHTS)
CLOCK & NURSE CALL DEVICES
6' -7
7' -0
ST
AN
D
IN
G 5'
-6 " O
.C
TELEVISION
OUTLET
FO
R
S
EA
TE
D
4' -0
" O .C
MOP BASIN
MOP SHELF
TYPICAL JANITORS CLOSET
2' -6
5' -6
TOWEL BAR
ACCESSIBLE
ROBE/COAT HOOK
ROBE/COAT
HOOK
TOILET ACCESSORIES
3' -4
5' -9
4' -0
6"
PAPER TOWEL
DISPENSER
2'-0" AT SIDEWALLS
AT COUNTER SINKS
1'-6" AT SIDEWALLS
AT LAVATORY
O .C
1"
O.C.
39" - 41"
3'-6" 1'-0"
9" O.C.
2'-0"
1/
2" M
IN
TO
T
O P
3' -0
6" 3'-0"
ACCESSIBLE TOILET
WALL MOUNTED
1-1/2"
DIAMETER
GRAB BAR
SANITARY NAPKIN
DISPOSAL
TOILET TISSUE
DISPENSER
TOILET SEAT
COVER
DISPENSER
1' -7
1' -6
BLOCKING
WALL PROTECTION
8'- 0"
HANDRAIL
OR DOOR FRAME
3" TO CORNERGUARD
CORNER GUARD
3'- 0"
3' -0
4'-0" MAX TO
HIGHEST OPERABLE
POINT - IF FIRE
EXTINGUISHER
OVER 40 LBS
3'-6" MAX HT.
FIRE EXTINGUISHER
CABINET
ELECTRICAL CABINET
6' -6
DUPLEX
OUTLET
SWITCH
THERMOSTAT
TELEPHONE
OR DATA
OUTLET
FIRE ALARM
PULL
INTERCOM
STATION
DUPLEX
OUTLET
COMPUTER
TERMINAL 1'
-6
MISC. WALL DEVICES
4' -0
1 HOUR FIRE SEPARATION WALL
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: ARCHITECT/ENGINEER OF RECORD
Date Checked Drawn
FULLY SPRINKLERED
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
Approved
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
1/
/2
3:
:1
PM
Au to de sk
D oc s:
//H ou st on V
A M ed ic al C en te r/A _2
2-
1-
BC
LC
V
A-
BL
D G
_S H
EL
L.
rv t
GENERAL INFORMATION
OKM
REPLACE BUILDING 121
MICHAEL E. DEBAKEY VAMC
2002 HOLCOMBE BOULEVARD
HOUSTON, TX 77030 JANUARY 24, 2025
100% CONSTRUCTION DOCUMENTS
RMC
G-002 2 3
580-324
GENERAL SYMBOL LEGEND
Scale: 3/8" = 1'-0"
1 STANDARD MOUNTING HEIGHTS
FIRE RATING LEGEND
BAR JOIST ON STEEL STRUCTURE, METAL DECKING, 6" (MIN) SLOPED
POLYISO INSULATION, TPO ROOFING
U-39
U-0.025
N/A
N/A
N/A
6" METAL STUDS, 5/8" GYP BD ON THE INTERIOR, R19 FOAM INSULATION, 5/8"
DENSGLASS SHEATHING, 2" OF RIGID INSULATION (R10), EIFS, METAL PANELS,
AND BURNISHED BLOCK CLADDING.
U - 0.084
R-29
N/A
N/A
N/A
3750 SF OF DOUBLE PANE GLAZING
U-0.450
N/A
N/A
LOW E REQUIRED
INSULATED METAL DOOR - U-0.370
N/A
N/A
N/A
N/A
N/A
N/A
SLAB ON GRADE BEAMS AND DRILLED PIERS
N/A
N/A
N/A
N/A
2A
A
2 3 4 5 6
B
D
C
752 SF
MECHANICAL
160 SF
ELEC
1982 SF
OPEN
OFFICE
97 SF
OFFICE
104 SF
OFFICE
102 SF
OFFICE
209 SF
OFFICE
102 SF
OFFICE
101 SF
OFFICE
26 358 SF
STAFF
CONFERENCE
ROOM
374 SF
OCCUPATIONAL
THERAPY
725 SF
COMMUNITY
ROOM
252 SF
RESOURCE/
COMPUTERS
368 SF
WAITING
160 SF
VEST
64 SF
TOILET
95 SF
MEDS
114 SF
EXAM
147 SF
FAMILY
CONSULT
213 SF
FAMILY
CONSULT
123 SF
OFFICE/CONSULT
11119 SF
OFFICE/CONSULT
117 SF
OFFICE/CONSULT
119 SF
OFFICE/CONSULT
14 67 SF
TLT
116 SF
OFFICE/CONSULT
1670 SF
HAC
1785 SF
SOILED
217 SF
STAFF
LOUNGE
71 SF
VEST
116 SF
OFFICE/CONSULT
113 SF
OFFICE/CONSULT
115 SF
OFFICE/CONSULT
112 SF
OFFICE/CONSULT
115 SF
TR
112 SF
OFFICE/CONSULT
116 SF
OFFICE/CONSULT
113 SF
OFFICE/CONSULT
116 SF
OFFICE/CONSULT
114 SF
OFFICE/CONSULT
115 SF
OFFICE/CONSULT
114 SF
OFFICE/CONSULT
117 SF
OFFICE/CONSULT
115 SF
OFFICE/CONSULT
222 SF
RECEPTION/CHECK-IN
410 SF
GROUP
ROOM 1
489 SF
GROUP
ROOM 2
61 SF
STAFF
TLT
62 SF
TOILET
59 SF
FIRE
RISER
ROOM
103 SF
STORAGE
523 SF
CORRIDOR
C01
215 SF
CORRIDOR
C02
596 SF
CORRIDOR
C06
121 SF
CORRIDOR
C04
215 SF
CORRIDOR
C03
241 SF
CORRIDOR
C05
2'
-0
123'-6"
4'
-0
DIAGONAL
DISTANCE OF 183'
1.7
E
A.5
B.11 B.10
FEC
FEC
FEC
FEC
FEC
FEC
FEC
ACTUAL EXIT
DISTANCE 180'
CLEAN
SUPPLY
07A
(NFPA 101 7.3.1.2
COLLABORATION
SPACE - OCCUPANCY
18)
(NFPA 101 7.3.1.2
COLLABORATION
SPACE - OCCUPANCY
24)
(NFPA 101 7.3.1.2
COLLABORATION
SPACE - OCCUPANCY
30)
KB
WALL MOUNTED
LADDER TO ROOF
HATCH
FD
FD
FD
FDFDFEC
EGRESS PATH
EGRESS IDENTIFICATION
FIRE EXTINGUISHER CABINET
KNOX BOXKB
FEC
EXIT SIGN (SHADED
AREA INDICATES
DIRECTION OF EGRESS)
PROJECT: MICHAEL E. DEBAKEY
VA MEDICAL CENTER
REPLACE BUILDING 121
ADDRESS: 2002 HOLCOMBE BLVD
HOUSTON, TX
CODE ENFORCEMENT JURISDICTION -
BUILDING: VETERANS AFFAIRS
CODE ENFORCEMENT JURISDICTION -
SITE: HOUSTON, TX
APPLICABLE CODES:
LIFE SAFETY CODE (NFPA 101 LATEST EDITION)
LIFE SAFETY CODE (NFPA 5000 LATEST EDITION)
INTERNATIONAL BUILDING CODE (LATEST EDITION)
INTERNATIONAL MECHANICAL CODE (LATEST EDITION)
INTERNATIONAL PLUMBING CODE (LATEST EDITION)
NATIONAL ELECTRIC CODE (LATEST EDITION)
ACCESSIBILITY CODE (ADAAG/ADA LATEST EDITION)
INTERNATIONAL FIRE CODE (LATEST EDITION)
PROJECT DESCRIPTION: ONE STORY, STAND ALONE
OUTPATIENT MENTAL HEALTH CLINIC
BUILDING DATA:
USE GROUP: B
CONSTRUCTION TYPE: II (000) - NON COMBUSTIBLE
OR LIMITED COMBUSTIBLE MATERIAL
(NFPA 101: TABLE A.8.2.1.2)
SPRINKLERED: FULLY SPRINK.
HEIGHT (ACTUAL): 18'-0"
NO. OF STORIES (ACTUAL): 1
GROSS BUILDING AREA (ACTUAL): 14,977 S.F.
HEIGHT AND AREA LIMITATIONS (ALLOWABLE):
(NFPA:101 TABLE 12.1.6): STORIES IN HEIGHT ( 1 STORY)
PERMITTED FOR ASSEMBLY OF ANY OCCUPANT LOAD.
HEIGHT (IBC TABLE 504.3): 75'-0" (ALLOWABLE)
NO. OF STORIES (IBC TABLE 506.4): 4 (ALLOWABLE)
SQUARE FOOTAGE (IBC 506.2): 69,000 S.F. (ALLOWABLE)
NO AREA MODIFICATION CALCULATIONS REQUIRED.
FIRE RESISTANCE RATING REQUIREMENTS
(NFPA 101: TABLE A8.2.1.2): TYPE II (000)
EXTERIOR BEARING WALLS: 0 HR
INTERIOR BEARING WALLS: 0 HR
COLUMNS: 0 HR
BEAMS: 0 HR
FLOOR/CEILING ASSEMBLIES: 0 HR
ROOF/CEILING ASSEMBLIES: 0 HR
INTERIOR NONBEARING WALLS: 0 HR
EXTERIOR NONBEARING WALLS: 0 HR
LIFE SAFETY SYSTEMS:
EMERGENCY LIGHTING: YES
EXIT SIGNS: YES
FIRE ALARM: YES
SMOKE DETECTION: YES
SPRINKLER SYSTEM: YES
EXIT REQUIREMENTS ( NFPA 101: TABLE 7.3.3.1):
MINIMUM EGRESS WIDTH = 148 X .2 = 29.6"
5'-0" MIN (CORRIDORS 6'-0" REQUIRED BY VA)
3'-6" MIN EXIT (DOORS) PROVIDED
EXIT ACCESS TRAVEL DISTANCE (NFPA 101: 38.2.6.3)
B OCCUPANCY W/ SPRINKLER = TRAVEL DISTANCE
SHALL NOT EXCEED 300'.
*ACTUAL MAX TRAVEL DISTANCE PROVIDED: 124'
EGRESS (NFPA 101: 7.5.1.1.1):
MINIMUM NUMBER OF EXITS: 2
*ACTUAL EXITS PROVIDED: 2
SEE LS PLAN FOR EXIT SEPARATION DISTANCE (NFPA
101: 7.5.1.3.3).
MAXIMUM DIAGONAL: 183'-0"
REQUIRED EXIT SEPARATION: THE MINIMUM
SEPARATION DISTANCE BETWEEN TWO EXITS, EXIT
ACCESSES, OR EXIT DISCHARGES, SHALL BE NOT LESS
THAN 1/3 THE LENGTH OF THE MAXIMUM OVERALL
DIAGONAL DIMENSION OF THE BUILDING OR AREA
SERVED.
*ACTUAL EXIT SEPARATION PROVIDED: 180'
BUILDING CODE SUMMARY
WALL
OPENING,
13"W x 31"H x 6-1/4"D
SEMI-RECESSED
FIRE EXTINGUISHER
CABINET, SIZED FOR
20 LB FIRE
EXTINGUISHER
SEALANT
SEE PLANS
FOR WALL
TYPESPLAN
NON-OCCUPIED SPACES: 4,415 SF
OCCUPIED SPACES: 10,562 SF
GROSS = 4,415 SF + 10,562 SF = 14, 977 SF
14,977 SF - 3,604 SF (COLLAB) = 11,373 SF
11,373 SF/150 = 76 (NFPA 101: 7.3.1.2)
COLLABORATION ROOMS (3,604 SF) OCCUPANCY (NFPA 101: 7.3.1.2)
= 72
TOTAL BUILDING OCCUPANCY: = 76 + 72 = 148
A. SEE SHEET A-001 FOR SYMBOLS AND
ABBREVIATIONS.
B. SEE CIVIL DRAWINGS FOR INFORMATION INCLUDING
CONCRETE SIDEWALKS, AND CONCRETE PADS.
CIVIL BACKGROUND DRAWING INFORMATION IS FOR
REFERENCE ONLY.
C. SEE STRUCTURAL DRAWINGS FOR FRAMING
INFORMATION & FRAMING DIMENSIONS. ALL
DIMENSIONS ARE FOR REFERENCE ONLY- VERIFY
ALL FRAMING WITH STRUCTURAL DRAWINGS.
D. REFER TO PLUMBING DRAWINGS FOR INFORMATION
CONCERNING PLUMBING FIXTURES AND PIPING
SYSTEM(S).
E. REFER TO MECHANICAL DRAWINGS FOR
INFORMATION CONCERNING HVAC SYSTEM(S).
F. REFER TO ELECTRICAL DRAWINGS FOR
INFORMATION CONCERNING POWER, LIGHTING AND
COMMUNICATION SYSTEM(S).
G. REFER TO ELECTRICAL DRAWING FOR FIRE ALARM
NOTIFICATION AND EMERGENCY EGRESS LIGHTING
LOCATIONS.
H. REFER TO PARTITION TYPES FOR FURTHER FIRE
SEPARATION REQUIREMENTS.
I. CONTRACTOR TO PROVIDE ALL ADDITIONAL
FRAMING NECESSARY FOR ALL OPENINGS AND
SUPPLEMENTAL FRAMING ABOVE PARTITIONS.
J. ALL FIRE RATED ASSEMBLIES SHALL BE INSTALLED
IN STRICT ACCORDANCE WITH TESTED ASSEMBLIES
INDICATED.
K. EXTEND PARTITIONS, BARRIERS, AND OTHER
SEPARATIONS TO BOTTOM OF ROOF/FLOOR DECK
ABOVE (OR AS DIRECTED BY UL ASSEMBLY) AND TO
EXTERIOR WALL. SEAL JOINT BETWEEN EDGES OF
PARTITION WITH FIRE RATED SEALANT AND/OR
INTUMESCENT ASSEMBLY.
L. STORAGE OF ANY FLAMMABLE OR COMBUSTIBLE
LIQUIDS IS UNDERSTOOD TO NOT BE WITHIN THE
BUILDING. STORAGE OF ANY MATERIAL IS TO BE IN
COMPLIANCE WITH ALL APPLICABLE CODES AND
AUTHORITIES HAVING JURISDICTION.
PARTITION LEGEND
NON-RATED INTERIOR
PARTITION WALL
NON-RATED INTERIOR
PARTITION WALL WITH
INSULATION
NON-RATED EXTERIOR WALL
WITH INSULATION
20 MINUTE SMOKE WALL
INTERIOR PARTITION
WITH INSULATION
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: ARCHITECT/ENGINEER OF RECORD
Date Checked Drawn
FULLY SPRINKLERED
U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
Approved
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
1/
/2
3:
:4
PM
Au to de sk
D oc s:
//H ou st on V
A M ed ic al C en te r/A _2
2-
1-
BC
LC
V
A-
BL
D G
_S H
EL
L.
rv t
LIFE SAFETY
EM
REPLACE BUILDING 121
MICHAEL E. DEBAKEY VAMC
2002 HOLCOMBE BOULEVARD
HOUSTON, TX 77030 JANUARY 24, 2025
100% CONSTRUCTION DOCUMENTS
GC
G-003 3 3
580-324
Scale: 1/8" = 1'-0"
1 LIFE SAFETY PLAN
LIFE SAFETY LEGEND
CODE INFORMATION
FIRE EXTINGUISHER CABINET
LIFE SAFETY LEGEND
LIFE SAFETY NOTES
NEW CONCRETE SIDEWALK
CONCRETE
ENTRANCE DRIVE
NEW CONCRETE
SIDEWALK
NEW CONCRETE
SIDEWALK
CHILLER PAD
N O
R
TH
0 4 8 1614,977 S.F. F.F. 46.80'
N
EW
C O
N C
R
ET
E
SI
D
EW
AL
K
File details come from the government source that posted it. Updated .