Amendment 0006 - Att.pdf

PDF 346 KB Posted

Attached to
Y1DA--580-324 | Replace/Construct Bldg 121 | Houston, TX Federal contract opportunity
Solicitation number
36C77625R0030_1
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This document is a certification letter from Protection Engineering Consultants, LLC (PEC) dated July 23, 2024, regarding the design compliance for Building 121 replacement at the Michael Debakey VA Medical Center in Houston. PEC is serving as a subconsultant to Ballard, providing specialized subject matter expertise in physical security and structural blast engineering, specifically certifying compliance with the VA Physical Security and Resiliency Design Manual (PSRDM). The letter confirms that after reviewing the 100% design package, PEC found the design compliant with PSRDM requirements and did not identify any components in the 95% design package requiring deviation or equivalency. The certification is subject to potential changes based on future design efforts or PSRDM updates.

View the file

Other files for this federal contract opportunity

Other files attached to Y1DA--580-324 | Replace/Construct Bldg 121 | Houston, TX, newest first.
File Type Posted
Amendment 0006 - Att.pdf PDF
Amendment 0006 - Att 4 - Updated RFI Log 6-20-25.docx DOCX document
Amendment 0006 - Att. 1 - Mechanical Addendum.pdf PDF
Amendment 0006.pdf PDF
Amendment 0005.pdf PDF
Amendment 0004 - Att. 5 - RFI 48 11 41 00 Food Storage Equipment.docx DOCX document
Amendment 0004 - Att. 6 - RFI 43 Bldg. 121 Floor Plan.pdf PDF
Amendment 0004 - Att. 4 - RFI 55 Contractor Map.png PNG image
Amendment 0004 - Att. 3 - RFI 53 Construction Fence Limit 121.png PNG image
Amendment 0004 - Att. 2 - Bldg. 121 Geotech Report.pdf PDF
Amendment 0004 - Att. 1 RFI Log.docx DOCX document
Amendment 0004.pdf PDF
Attachment A - Spec 01 31 00.01 Project Management and Coordination.pdf PDF
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
Bldg. 121 Floor plan.pdf PDF
Site Visit Sign-in-sheet..pdf PDF
Site Visit Agenda.pdf PDF
Amendment 0001.pdf PDF
Attachment 4 - Drawings Civil.pdf PDF
Attachment 13 - Drawings Technology.pdf PDF
Attachment 11 - Drawings Mechanical.pdf PDF
Attachment 8 - Drawings Interior.pdf PDF
Attachment 7 - Drawings Architectural.pdf PDF
Attachment 2 - Houston Bldg 121 - Specs - Vol 2.pdf PDF
Attachment 15 - Wage Determination Harris County.pdf PDF
Attachment 6 - Drawings Structural.pdf PDF
Attachment 9 - Drawings Fire Suppression.pdf PDF
Attachment 16 - PPQ.docx DOCX document
Attachment 1 - Houston Bldg 121 - Specs - Vol 1.pdf PDF
Attachment 5 - Drawings Landscape.pdf PDF
Attachment 3 - Drawings General.pdf PDF
36C77625R0030_1.pdf PDF
Attachment 12 - Drawings Electrical.pdf PDF
Attachment 10 - Drawings Plumbing.pdf PDF
Attachment 14 - Limitations on Subcontracting - Construction.docx DOCX document
Show all 36

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date:

From:

To:

Subject:

July 23, 2024

Protection Engineering Consultants, LLC (PEC) – PSRDM subconsultant to Ballard

Ballard Project Manager; File

Certification Letter – Bldg 121 Design at Michael Debakey VA Medical Center

Background:

1. Ballard is currently designing a building 121 replacement at the Houston VA Medical Center.

2. PEC is participating as a subconsultant on that design team, specifically representing the following Subject Matter Specialists required by the VA Physical Security and Resiliency Design Manual (PSRDM):

a. Certified Physical Security Specialist

b. Structural Blast Specialist

Certification:

PEC certifies that, based on our review of the 100% design package that the design appears compliant with the PSRDM requirements in place at the time of submission relevant to the above disciplines for this project.

Further, in the prior evaluation, PEC did not identify components of the 95% design package that would seem to require deviation or equivalency based on PSRDM requirements.

This certification statement is subject to change based on further design efforts or updates to the PSRDM, if any. If no material changes are made, this shall serve as the PSRDM Compliance Letter for the project specific to the PEC specialist disciplines above.

Respectfully Submitted:

Brandon R. Kehl, CPP Senior Security Consultant

File details come from the government source that posted it. Updated .