Attachment 2e Combined Drawings Construct Addition and Renovated Bldg 60.pdf
PDF 13 MB Posted
- Attached to
- Y1DA--589-703 Construct Addition and Renovate Community Living Center, Building 60 (VA-24-00028736)
- Solicitation number
- 36C77624B0019
About this file
This document appears to be Attachment 2e, Combined Drawings for the Construct Addition and Renovated Building 60 project, related to Solicitation Number 36C77624B0019. The solicitation is for a project to construct an addition and renovate the Community Living Center, Building 60, for the Department of Veterans Affairs Technology Acquisition Center Austin. The solicitation includes a Statement of Work in Attachment 1. No other details about the required products or services, response dates, award information, pricing terms, set asides, or incumbents are provided in this attachment, which appears to contain only construction drawings.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BASE
PLAN
HEADUNDERSIDE OF
STRUCTURE
LINE OF CEILING,
REF RCP
METAL RUNNER
FASTENED @ 24" OC
WALL FINISH, REF
FINISH SCHEDULE
5/8" "TYPE X" GYPSUM
BOARD, EACH SIDE
METAL RUNNER,
FASTENED @ 24" OC
FINISH FLOOR, REF
FINISH SCHEDULE
BASE AS SCHEDULED
METAL STUD
FRAMING @ 16" OC
FIRE RATED SEALANT
AROUND PERIMETER
FIRE RATED SEALANT
AROUND PERIMETER
ICRA WALL PARTITION
1. THE ICRA DESIGNATION FOR THIS PROJECT IS CONSTRUCTION TYPE 'D' & LEVEL 'IV' CLASS OF
PRECAUTION OF INFECTION CONTROL ACTIVITIES. HARD SURFACE BARRIERS SHALL BE
USED.
2. WITH REGARD FOR REMEDIATION REQUIREMENTS, AN ENTRY VESTIBULE FOR CLOTHING
CHANGES TO TYVEK SUITS SHALL BE PROVIDED ADJACENT TO THE HARD SURFACE BARRIER
OR ENTRY VESTIBULE. UPON COMPLETION OF THE CONSTRUCTION PHASE, DUST BARRIERS
SHALL BE REMOVED CAREFULLY TO MINIMIZE SPREADING OF DUST AND THE CONTRACTOR
SHALL PROVIDE TEMPORARY DUST PROTECTION BEFORE REMOVAL OF THE HARD SURFACE
BARRIERS. A DWYER GAUGE SHALL BE USED AT THE CONSTRUCTION ENTRY TO VALIDATE
NEGATIVE AIR FLOWS. AFTER EACH PHASE, PERFORM TASKS STATED IN NOTE 11.
3. TRAFFIC CONTROL: CONTRACTOR SHALL PROVIDE STICKY MATS AT PLASTIC BARRIER
ENTRANCES OR CONSTRUCTION ENTRY VESTIBULE AND CHANGE DAILY OR MORE OFTEN AS
NEEDED TO PREVENT THE SPREAD OF DUST AND DEBRIS INTO ADJACENT CLEAN SPACE. ANY
DUST TRACKED OUTSIDE OF THE CONSTRUCTION ENTRY SHALL BE IMMEDIATELY CLEANED.
EGRESS PATHS SHALL BE FREE OF DEBRIS AND COR SHALL DESIGNATE ELEVATORS FOR USE
DURING APPROVED WORKING HOURS. ONLY AUTHORIZED PERSONNEL SHALL BE ALLOWED
TO ENTER THE CONSTRUCTION AREA. SIGNAGE SHALL DIRECT PEDESTRIAN TRAFFIC AWAY
FROM THE CONSTRUCTION AREA AND MATERIALS. REFER SECURITY INFORMATION FOR
ALTERNATE ACCESS REQUIREMENTS.
4. MATERIAL TRANSPORT: CONTRACTOR SHALL USE ISOLATION CARTS TO TRANSFER
CONSTRUCTION MATERIAL IN AND OUT OF THE CONSTRUCTION AREA. A CLEAN CART SHALL
BE USED FOR TRANSPORTING MATERIAL TO THE CONSTRUCTION AREA. CARTS ARE TO BE
CLEANED AND COVERED BEFORE LEAVING THE CONSTRUCTION AREA.
5. DEMOLITION DEBRIS: DEBRIS SHALL BE REMOVED IN CARTS WITH TIGHTLY FITTED COVERS.
DEBRIS TRANSPORT TRAFFIC ROUTES SHALL BE ESTABLISHED TO MINIMIZE USE OF
ELEVATORS. TRANSPORT OF DEBRIS WILL OCCUR DURING THE LOWEST PERIOD OF ACTIVITY
IN THE ADJACENT UNIT. DEBRIS SHALL BE REMOVED DAILY AND AT TIMES SPECIFIED BY THE
COR.
6. AIR SYSTEM FLOW: THE COR SHALL VERIFY AND NOTIFY THE CONTRACTOR WHETHER THE
CONSTRUCTION AREA USES FRESH/OUTSIDE OR RE-CIRCULATED AIR. FILTERS SHALL BE
ADDED OR RETURN VENTS COVERED WITH FILTER MATERIAL OR PLASTIC. AIR MUST FLOW
FROM CLEAN TO DIRTY AREAS.
7. NEGATIVE AIR PRESSURE: THE AIR WITHIN THE CONSTRUCTION AREA SHALL BE NEGATIVE
WITH RESPECT TO SURROUNDING AREAS AND WITH NO DISRUPTION TO AIR SYSTEMS OF
ADJACENT AREAS. USE OF THE NEGATIVE AIR PRESSURE SYSTEM WITHIN THE ENCLOSURE
TO REMOVE DUST SHALL PASS AIR THROUGH AN INDUSTRIAL GRADE PORTABLE HEPA FILTER
CAPABLE OF FILTRATION RATES OF 300-800 CUBIC FEET PER MINUTE. SYSTEM SHALL
MAINTAIN NEGATIVE PRESSURE REQUIREMENT OF -0.03". FOR CONSTRUCTION AREA AIR
RETURNED TO THE HVAC SYSTEM, A PRE-FILTER AND HEPA FILTER SHALL BE USED BEFORE
EXHAUST TO PREVENT CONTAMINATION OF HVAC SYSTEM DUCTING.
8. ADJACENT AREAS: THE STATUS OF SEALED PENETRATIONS AND INTACT CEILING SHALL BE
VERIFIED DAILY.
9. AIR EXCHANGE RATES AND PRESSURE RELATIONSHIPS: VAMC AND CONTRACTOR SHALL
VERIFY AND MAINTAIN PROPER AIR EXCHANGE RATES IN CRITICAL AREAS NEAR
CONSTRUCTION ACTIVITY. CONTRACTOR TO ENSURE AIR IS RE-CIRCULATED WITH
FILTRATION FROM ALL CONSTRUCTION AREAS. PROVIDE AIR PRESSURE TESTING
THROUGHOUT THE PROJECT IN ACCORDANCE WITH COR PROVIDED REQUIREMENTS.
10. WORKSITE CLOTHING: CONTRACTOR PERSONNEL CLOTHING SHALL BE FREE OF LOOSE SOIL
AND DEBRIS BEFORE LEAVING THE CONSTRUCTION AREA. IF PROTECTIVE APPAREL IS NOT
WORN (EXAMPLES: COVERALLS, FOOTGEAR, AND HEADGEAR) A HEPA-FILTERED VACUUM
SHALL BE USED TO REMOVE DUST FROM CLOTHING BEFORE LEAVING THE BARRICADE. IF
PROTECTIVE APPAREL IS UTILIZED, THE CONTRACTOR SHALL CONSTRUCT A SPACE OR
ANTEROOM FOR CHANGING OF CLOTHING.
11. POST CONSTRUCTION: DO NOT REMOVE BARRIERS AND KEEP ALL HVAC ISOLATION IN PLACE
UNTIL CONTRACTOR HAS CLEANED THE CONSTRUCTION SITE, VA EMS STAFF HAS
PERFORMED A TERMINAL CLEANING, AND VA INFECTIOUS DISEASE CONTROL HAS INSPECTED
AND APPROVED THE CLEANING.
12. FIRE ALARMS AND OTHER LIFE SAFETY FIXTURES WITHIN THE ICRA BARRIERS OF THE
CONSTRUCTION AREA SHALL BE TEMPORARILY RELOCATED TO THE OUTSIDE OF BARRIERS.
13. REFER TO SPECIFICATION SECTION 01 35 26 "SAFETY REQUIREMENTS" FOR ADDITIONAL ILSM
PROCEDURES AS REQUIRED BY THE VA DURING CONSTRUCTION ACTIVITIES.
GENERAL ICRA NOTES
BUILDING
EXPANSION
TRAVEL DISTANCE = 148' - 0"
TRAVEL DISTANCE = 109' - 3"
T R
A V
E L
D
IS
T A
N C
E
2"
HOSPICE
ROOM
1B131
HOSPICE
ROOM
1B130
BREAK
ROOM
1B122
TLC ROOM
1B121
PSYCHOLOGIST
1B123
SOCIAL
WORKER
1B143
TLC ROOM
1B144
TLC ROOM
1B145
TLC ROOM
1B147
TLC
KITCHEN
1B146
TLC MEDS
1B149
TLC ROOM
1B116
TLC ROOM
1B114
TLC ROOM
1B112
TLC ROOM
1B110
TLC ROOM
1B108
TLC ROOM
1B106
SOILED
UTILITY
1B104
CLEAN
LINEN
1B117
TLC ROOM
1B115
TLC ROOM
1B113
TLC ROOM
1B111
TLC ROOM
1B109
TLC ROOM
1B107
TLC ROOM
1B105
COPY
1B103B
OPEN
OFFICE
1B103
OFFICE
1B103A
CONFERENCE
ROOM
1B101
ACTIVITIES
ROOM
1B100
SPD
STORAGE
1B152
COMPUTER
CHARGING
1B153LOBBY
OFFICE
OPEN
OFFICE
OFFICE
101B
OFFICE
101A
WAITING
ROOM
ICRA WALL
PARTITION
108C
114A 108B
103A
109A
113A
108A
110E 110F
110D 110C
110B 110A
1B133
1B133A
1B134
1B135A
1B1351B1361B1371B138
1B137A 1B136A
1B130
1B131
1B131A
1B132
1B1251B127
1B141
1B142
1B140
1B124
1B1261B128
1B129
1B140A
2.58 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
KEY PLAN
B
N
SPUR #: 2015
/5
/2
:3
:4
A
M
INTERIM LIFE SAFETY PLAN
NR 007 OF 221DLK
BID DOCUMENTS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
GI015
N
3/32" = 1'-0"
INTERIM LIFE SAFETY PLAN1
No. REVISION DESCRIPTION DATE
KEYNOTE LEGEND
2.58 CONTRACTOR TO COORDINATE TEMPORARY SIGNAGE WITH THE VA DURING
CONSTRUCTION.
FD
FD
FD
FD
FD
FD
FD
255 SF
RESIDENT
RESIDENT
252 SF
RESIDENT
RESIDENT
82 SF
BATH
122A
BATH
122A
286 SF
RESIDENT,
BARIATRIC
RESIDENT,
BARIATRIC
84 SF
BATH
119A
BATH
119A
163 SF
IT ROOM
IT ROOM
61 SF
FIRE RISER RM
115A
FIRE RISER RM
115A
109 SF
ELECTRICAL
ELECTRICAL
214 SF
BATHING RM
BATHING RM
TOILET
117A 185 SF
HOUSE OFC
HOUSE OFC
95 SF
CLEAN SUPPLY
CLEAN SUPPLY
76 SF
SOILED UTL
SOILED UTL
78 SF
KITCHEN
KITCHEN
355 SF
DINING
133B
DINING
133B
447 SF
LIVING ROOM
133A
LIVING ROOM
133A
41 SF
PANTRY
133C
PANTRY
133C
23 SF
HSKPG
133D
HSKPG
133D
83 SF
BATH
137A
BATH
137A
261 SF
RESIDENT
RESIDENT
260 SF
RESIDENT
RESIDENT
255 SF
RESIDENT
RESIDENT
255 SF
RESIDENT
RESIDENT
255 SF
RESIDENT
RESIDENT
255 SF
RESIDENT
RESIDENT
255 SF
RESIDENT
RESIDENT
255 SF
RESIDENT
RESIDENT
263 SF
RESIDENT
RESIDENT
84 SF
BATH
143A
BATH
143A
83 SF
BATH
142A
BATH
142A
83 SF
BATH
140A
BATH
140A
83 SF
BATH
139A
BATH
139A
83 SF
BATH
136A
BATH
136A
83 SF
BATH
135A
BATH
135A
83 SF
BATH
134A
BATH
134A
956 SF
MULTIPURPOSE/
ACTIVITY ROOM
MULTIPURPOSE/
ACTIVITY ROOM
132144 SF
MP STOR
132A
MP STOR
132A
197 SF
ART ROOM
ART ROOM
83 SF
BATH
138A
BATH
138A
83 SF
BATH
141A
BATH
141A
202 SF
DEN
DEN
83 SF
BATH
145A
BATH
145A
304 SF
RESIDENT
RESIDENT
299 SF
RESIDENT
RESIDENT
84 SF
BATH
146A
BATH
146A
166 SF
STAFF LOUNGE
STAFF LOUNGE
54 SF
TLT
TLT
121 SF
HOUSE LNDRY
HOUSE LNDRY
92 SF
HOUSE STOR.
HOUSE STOR.
102 SF
MED
MED
245 SF
CONF. / PRIVATE
DINING
CONF. / PRIVATE
DINING
61 SF
TLT
TLT
129 235 SF
RESIDENT
RESIDENT
RESIDENT
264 SF
RESIDENT
RESIDENT
53 SF
HAC
HAC
102 SF
EQ. STOR
EQ. STOR
84 SF
BATH
151A
BATH
151A
106 SF
RT OFC
RT OFC
BATH
152A
2 HOUR FIRE
196 SF
VESTIBULE
006A
VESTIBULE
006A CRASH CART
005A
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
TRAVEL DISTANCE: 55'
TRAVEL DISTANCE: 105'
TRAVEL
DISTANCE: 148'
TRAVEL
DISTANCE: 140'
FEC
FEC
FEC
FEC
FEC
F E
C
T R
A V
E L
D
IS
T A
N C
E : 5
2'
EXTERIOR
COURTYARD
EXTERIOR
COURTYARD
F E
C
FEC
T R
A V
E L
D
IS
T A
N C
E : 6
8'
T R
A V
E L
D
IS
T A
N C
E : 8
0'
108A
101B101A
1B105 1B107 1B109 1B111 1B113 1B1151B113A
FIRE - 1 HOUR
FIRE - 2 HOUR
SMOKE PARTITION
PARTITION LEGEND
NEW NON-RATED WALLS
EXISTING WALL TO REMAIN
EXISTING SMOKE PARTITION
EXISTING BUILDING HEIGHT: BUILDING 60
HEIGHT LIMITATION: 1 STORY (2021 IBC TABLE 504.4), 55'-0" (2021 IBC TABLE 504.3)
ACTUAL HEIGHT: 1 STORY, APPROX. 28'-6" HEIGHT
NEW BUILDING HEIGHT: BUILDING 60 ADDITION
HEIGHT LIMITATION: 3 STORIES (2021 IBC TABLE 504.4), 85'-0" (2021 IBC TABLE 504.3)
PROPOSED HEIGHT: 1 STORY, APPROX. 33'-0" HEIGHT
BUILDING AREA:
AREA LIMITATION (I2 - IIB): 33,000 SQUARE FEET (2021 IBC TABLE 506.2)
TOTAL EXISTING AREA 29,097 GROSS SQUARE FEET
EXISTING RENOVATION AREA 13,542 GROSS SQUARE FEET
TOTAL NEW ADDITION AREA 16,411 GROSS SQUARE FEET
NFPA 101-2021 CHAPTER 7- TABLE 7.3.1.2 OCCUPANT LOADS
NFPA 101-2021 CHAPTER 7- 7.2.1.2.3.2) MINIMIM DOOR LEAF WIDTH
MINIMUM DOOR OPENING WIDTH OF 32"
NFPA 101-2021 CHAPTER 7- TABLE 7.3.3.1 EGRESS CAPACITY FACTORS
NFPA 220-2021 CHAPTER 4- TABLE 4.1.1
CONSTRUCTION TYPE: TYPE II (111)
FIRE RESISTANCE RATINGS
COLUMNS: 1 HR
BEAM, GIRDERS, TRUSSES: 1 HR
FLOOR/CEILING ASSEMBLIES: 1 HR
ROOF/CEILING ASSEMBLIES: 1 HR
EXTERIOR NON-BEARING WALLS: 0 HR
INTERIOR NON-BEARING WALLS: 0 HR
FIRE-RESISTIVE REQUIREMENTS:
NON COMBUSTIBLE MATERIALS FOR STRUCTURAL FRAME, FLOORS, ROOF DECK, EXTERIOR
NON-BEARING WALLS, INTERIOR NON-BEARING WALLS (U.N.O. AT EXTERIOR)
BUILDING OCCUPANCY (NFPA 101):
ADDITION: CHAPTER 18: NEW HEALTHCARE
RENOVATION: CHAPTER 19: EXISTING HEALTHCARE
NFPA 101-2021 CHAPTERS 18 - 19 TRAVEL DISTANCE
ADDITION: 200' (NFPA 101: 18.2.6.2)
RENOVATION: 200' (NFPA 101: 19.2.6.2)
NFPA 101-2021 CHAPTERS 18 - 19 SLEEPING ROOM EXIT ACCESS TRAVEL DISTANCE
ADDITION: 50' (NFPA 101: 18.2.6.2.3)
RENOVATION: 50' (NFPA 101: 19.2.6.2.4)
NFPA 101-2021 CHAPTERS 18 - 19 COMMON PATH OF TRAVEL
ADDITION: 100' (NFPA 101: 18.2.5.3)
RENOVATION: 100' (NFPA 101: 18.2.5.3
NFPA 101-2021 CHAPTERS 18 - 19 DEAD END CORRIDOR
ADDITION: 30' (NFPA 101: 18.2.5.2)
RENOVATION: 30' (EXISTING) (NFPA 101: 19.2.5.2)
PROTECTED AREAS:
STORAGE ROOMS LARGER THAN 100 FT2 AND STORING COMBUSTABLE MATERIAL - 1 HR FIRE
BARRIER REQUIRED PER NFPA 101: 18.3.2 AND 8.3.
STORAGE ROOMS LARGER THAN 50 FT2 AND NOT EXCEEDING 100 FT2 AND STORING
COMBUSTABLE MATERIAL - SMOKE PARTITION WITH SPRINKLER PROTECTION REQUIRED PER
VA FIRE PROTECTION DESIGN MANUAL 3.1.A, AND NFPA 101: 18.3.2.1 AND 8.4.
SMOKE COMPARTMENTALIZATION: REQUIRED PER NFPA 101: 18.3.7 AND 19.3.7.
FIRE ALARM SYSTEM: REQUIRED/PROVIDED AUTOMATIC SYSTEM.
STANDPIPES: NOT REQUIRED / NOT PROVIDED.
LIFE SAFETY CODE ANALYSIS
LIFE SAFETY LEGEND
FACP
FEC
FIRE ALARM CONTROL PANEL
FIRE EXTINGUISHER CABINET
EXIT LIGHT / SIGN
NOT IN SCOPE
BUILDING EXIT
EGRESS PATH
AED AUTOMATED EXTERNAL
DEFIBRILLATOR, GC TO COORDINATE
ROUGH-IN CONDITION WITH VA
PROVIDED EQUIPMENT
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
KEY PLAN
A
N
SPUR #: 2015
/5
/2
:3
:4
A
M
LIFE SAFETY PLAN - AREA A
NR 008 OF 221DLK
BID DOCUMENTS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
GI016
N
1/8" = 1'-0" 1/ AE201
LEVEL 1 - LIFE SAFETY PLAN - AREA A1
ASSEMBLY - FIXED SEATING 30 SFSF/PERSON
ASSEMBLY - LESS CONCENTRATED
USE, WITHOUT FIXED SEATING
15 SFSF/PERSON
ASSEMBLY, KITCHENS 100 SFSF/PERSON
BUSINESS 150 SFSF/PERSON
HEALTHCARE - SLEEPING
DEPARTMENTS
120 SFSF/PERSON
STORAGE USE, OTHER 300 SFSF/PERSON
OCCUPANT TYPE
LEVEL COMPONENTS
(WIDTH/PERSON)
STAIRWAYS
(WIDTH/PERSON)
ASSEMBLY - FIXED SEATING .2" N/A
ASSEMBLY - LESS CONCENTRATED
USE, WITHOUT FIXED SEATING
.2" N/A
ASSEMBLY, KITCHENS .2" N/A
BUSINESS .2" N/A
HEALTHCARE - SLEEPING
DEPARTMENTS
<varies> <varies>
STORAGE USE, OTHER <varies> <varies>
No. REVISION DESCRIPTION DATE
FD
FD
FD
FDFD
FIRE - 1 HOUR
FIRE - 2 HOUR
SMOKE PARTITION
PARTITION LEGEND
NEW NON-RATED WALLS
EXISTING WALL TO REMAIN
EXISTING SMOKE PARTITION
EXISTING BUILDING HEIGHT: BUILDING 60
HEIGHT LIMITATION: 1 STORY (2021 IBC TABLE 504.4), 55'-0" (2021 IBC TABLE 504.3)
ACTUAL HEIGHT: 1 STORY, APPROX. 28'-6" HEIGHT
NEW BUILDING HEIGHT: BUILDING 60 ADDITION
HEIGHT LIMITATION: 3 STORIES (2021 IBC TABLE 504.4), 85'-0" (2021 IBC TABLE 504.3)
PROPOSED HEIGHT: 1 STORY, APPROX. 33'-0" HEIGHT
BUILDING AREA:
AREA LIMITATION (I2 - IIB): 33,000 SQUARE FEET (2021 IBC TABLE 506.2)
TOTAL EXISTING AREA 29,097 GROSS SQUARE FEET
EXISTING RENOVATION AREA 13,542 GROSS SQUARE FEET
TOTAL NEW ADDITION AREA 16,411 GROSS SQUARE FEET
NFPA 101-2021 CHAPTER 7- TABLE 7.3.1.2 OCCUPANT LOADS
NFPA 101-2021 CHAPTER 7- 7.2.1.2.3.2) MINIMIM DOOR LEAF WIDTH
MINIMUM DOOR OPENING WIDTH OF 32"
NFPA 101-2021 CHAPTER 7- TABLE 7.3.3.1 EGRESS CAPACITY FACTORS
NFPA 220-2021 CHAPTER 4- TABLE 4.1.1
CONSTRUCTION TYPE: TYPE II (111)
FIRE RESISTANCE RATINGS
COLUMNS: 1 HR
BEAM, GIRDERS, TRUSSES: 1 HR
FLOOR/CEILING ASSEMBLIES: 1 HR
ROOF/CEILING ASSEMBLIES: 1 HR
EXTERIOR NON-BEARING WALLS: 0 HR
INTERIOR NON-BEARING WALLS: 0 HR
FIRE-RESISTIVE REQUIREMENTS:
NON COMBUSTIBLE MATERIALS FOR STRUCTURAL FRAME, FLOORS, ROOF DECK, EXTERIOR
NON-BEARING WALLS, INTERIOR NON-BEARING WALLS (U.N.O. AT EXTERIOR)
BUILDING OCCUPANCY (NFPA 101):
ADDITION: CHAPTER 18: NEW HEALTHCARE
RENOVATION: CHAPTER 19: EXISTING HEALTHCARE
NFPA 101-2021 CHAPTERS 18 - 19 TRAVEL DISTANCE
ADDITION: 200' (NFPA 101: 18.2.6.2)
RENOVATION: 200' (NFPA 101: 19.2.6.2)
NFPA 101-2021 CHAPTERS 18 - 19 SLEEPING ROOM EXIT ACCESS TRAVEL DISTANCE
ADDITION: 50' (NFPA 101: 18.2.6.2.3)
RENOVATION: 50' (NFPA 101: 19.2.6.2.4)
NFPA 101-2021 CHAPTERS 18 - 19 COMMON PATH OF TRAVEL
ADDITION: 100' (NFPA 101: 18.2.5.3)
RENOVATION: 100' (NFPA 101: 18.2.5.3
NFPA 101-2021 CHAPTERS 18 - 19 DEAD END CORRIDOR
ADDITION: 30' (NFPA 101: 18.2.5.2)
RENOVATION: 30' (EXISTING) (NFPA 101: 19.2.5.2)
PROTECTED AREAS:
STORAGE ROOMS LARGER THAN 100 FT2 AND STORING COMBUSTABLE MATERIAL - 1 HR FIRE
BARRIER REQUIRED PER NFPA 101: 18.3.2 AND 8.3.
STORAGE ROOMS LARGER THAN 50 FT2 AND NOT EXCEEDING 100 FT2 AND STORING
COMBUSTABLE MATERIAL - SMOKE PARTITION WITH SPRINKLER PROTECTION REQUIRED PER
VA FIRE PROTECTION DESIGN MANUAL 3.1.A, AND NFPA 101: 18.3.2.1 AND 8.4.
SMOKE COMPARTMENTALIZATION: REQUIRED PER NFPA 101: 18.3.7 AND 19.3.7.
FIRE ALARM SYSTEM: REQUIRED/PROVIDED AUTOMATIC SYSTEM.
STANDPIPES: NOT REQUIRED / NOT PROVIDED.
LIFE SAFETY CODE ANALYSIS
LIFE SAFETY LEGEND
FACP
FEC
FIRE ALARM CONTROL PANEL
FIRE EXTINGUISHER CABINET
EXIT LIGHT / SIGN
NOT IN SCOPE
BUILDING EXIT
EGRESS PATH
AED AUTOMATED EXTERNAL
DEFIBRILLATOR, GC TO COORDINATE
ROUGH-IN CONDITION WITH VA
PROVIDED EQUIPMENT
RESIDENT - B2
201 SF
RESIDENT - B2
RESIDENT - B2
201 SF
RESIDENT - B2
RESIDENT - B2
200 SF
RESIDENT - B2
RESIDENT - B2
84 SF
BATH
158A
BATH
158A
84 SF
BATH
157A
BATH
157A
82 SF
BATH
156A
BATH
156A
75 SF
BATH
155A
BATH
155A
240 SF
RESIDENT - B1
RESIDENT - B1
241 SF
RESIDENT - B1
RESIDENT - B1
83 SF
BATH
153A
BATH
153A
48 SF
HAC
HAC
214 SF
RESIDENT - B1
RESIDENT - B1
213 SF
RESIDENT - B1
RESIDENT - B1
84 SF
BATH
162A
BATH
162A
83 SF
BATH
160A
BATH
160A
218 SF
RESIDENT - B1
RESIDENT - B1
83 SF
BATH
164A
BATH
164A
83 SF
BATH
161A
BATH
161A
82 SF
BATH
159A
BATH
159A
83 SF
BATH
163A
BATH
163A
99 SF
MEDS
MEDS
82 SF
BATH
173A
BATH
173A
207 SF
RESIDENT - B2
RESIDENT - B2
02 FULL
167A
02 USED
167B
122 SF
CLEAN SUPPLY
CLEAN SUPPLY
77 SF
SOILED UTL
SOILED UTL
105 SF
EQUIP STOR
EQUIP STOR
105 SF
SW OFC
SW OFC
103 SF
NRS LDR OFC
NRS LDR OFC
103 SF
MED DIR OFC
MED DIR OFC
136 SF
CLEAN LINEN
CLEAN LINEN
132 SF
SOILED UTL
SOILED UTL
135 SF
GENERAL STOR
GENERAL STOR
189 SF
TEAM WORKRM
TEAM WORKRM
188 SF
TEAM WORKRM
TEAM WORKRM
182 SF
DEN
DEN
190 SF
BATHING RM
BATHING RM
63 SF
TLT
176A
TLT
176A
207 SF
RESIDENT - B2
RESIDENT - B2
82 SF
BATH
175A
BATH
175A
22 SF
ELEC
ELEC
128 SF
H. LAUNDRY
H. LAUNDRY
97 SF
DIR OFC
DIR OFC
58 SF
TLT
184A
TLT
184A
200 SF
RESIDENT - B2
RESIDENT - B2
201 SF
RESIDENT - B2
RESIDENT - B2
60 SF
H. STOR
H. STOR
117 SF
HOUSE OFC
HOUSE OFC
CLC RECEP
100A
143 SF
KITCHEN
KITCHEN
249 SF
DINING
166B
DINING
166B
463 SF
LIVING ROOM
166A
LIVING ROOM
166A
626 SF
RESIDENT DINING
RESIDENT DINING
MOP
131B
17 SF
HAC
166D
HAC
166D
40 SF
PANTRY
166C
PANTRY
166C
17 SF
CRASH CART
013A
CRASH CART
013A
N&FS KITCHEN/
SERVERY
131A
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
F E
C
TRAVEL DISTANCE: 90'
TRAVEL DISTANCE: 100'TRAVEL DISTANCE: 113' TRAVEL DISTANCE: 87'
T R
A V
E L
D
IS
T A
N C
E : 1
FEC FEC
FEC
F E
C
T R
A V
E L
D
IS
T A
N C
E
T R
A V
E L
D
IS
T A
N C
E : 7
7'
T R
A V
E L
D
IS
T A
N C
E
0'
FEC
VESTIBULE
001A
WAITING
PT/OT RECEP
100B
CORRIDOR
EXAM
104 103 106 108
103A
109A
113A
110E
110F
110D 110C
110B 110A
1B133
1B133A
1B134
1B135A
1B1351B1361B1371B138
1B137A 1B136A
1B130
1B131
1B131A
1B132
1B1251B127
1B141
1B124
1B142
1B140
1B1261B1281B129
VESTIBULE
014A
SSTV
131C
HAC
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
KEY PLAN
B
N
SPUR #: 2015
/5
/2
:3
:5
A
M
LIFE SAFETY PLAN - AREA B
NR 009 OF 221DLK
BID DOCUMENTS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
GI017
N
1/8" = 1'-0"
LEVEL 1 - LIFE SAFETY PLAN - AREA B1
ASSEMBLY - FIXED SEATING 30 SFSF/PERSON
ASSEMBLY - LESS CONCENTRATED
USE, WITHOUT FIXED SEATING
15 SFSF/PERSON
ASSEMBLY, KITCHENS 100 SFSF/PERSON
BUSINESS 150 SFSF/PERSON
HEALTHCARE - SLEEPING
DEPARTMENTS
120 SFSF/PERSON
STORAGE USE, OTHER 300 SFSF/PERSON
OCCUPANT TYPE
LEVEL COMPONENTS
(WIDTH/PERSON)
STAIRWAYS
(WIDTH/PERSON)
ASSEMBLY - FIXED SEATING .2" N/A
ASSEMBLY - LESS CONCENTRATED
USE, WITHOUT FIXED SEATING
.2" N/A
ASSEMBLY, KITCHENS .2" N/A
BUSINESS .2" N/A
HEALTHCARE - SLEEPING
DEPARTMENTS
<varies> <varies>
STORAGE USE, OTHER <varies> <varies>
E12E11E10E9AE8A
ED
EE
EF
EG
E13
E7
EF1
EH
P
E8 E9
EB
EC
F
D
A
876543
K
I
H
J
5.521
C
96.5
B
E
2.5 3.5
N
G
C.3
AREA B
AREA A
5'-2 5/16" 3'-0 7/8" 3'-3 3/16" 5'-2 1/4"
7'-7 5/16" 7'-7 1/16"
'-2
/2
" 3' -0
/8
'-2
/2
3'-3 7/16" 5'-2 1/4"
'-2
/2
3' -0
7'-7 3/8"
12'-2 3/8"
7' -7
/4
"3'-0"
5' -2
/4
'-2
/8
7'-7 3/8"
5'-2 1/4"
3' -0
'-2
/8
5'-2 1/4"
3' -0
7'-7 1/8"
5'-2 1/4"
2'-4 13/16"2'-4 13/16" 2'-5 1/8"
'-2
/8
5'-2 1/8"
3' -0
7'-7 3/8" 1'-6 1/4"
7'-7 1/8"
5'-2 1/4"
'-2
/8
7'-7 3/8" 1'-6 1/4"
7'-7 1/4"
3' -0
5'-2 1/4"5'-2 1/4"5'-2 1/4"5'-2 1/4"
3' -0
'-2
/8
7'-7"
1'-0 1/4" 6 1/8"
7'-7 1/8"
7' -7
/4
12'-2 3/8"
3'-0"
5' -2
/4
7' -1
1/
4"
12'-4 3/8"
5' -2
/4
3'-0"
2'-8 5/8"
2' -1
5/
8"
12'-4 1/4"
'-8
/2
1' -2
/2
1'-9"
8'-7"
8' -8
/8
7' -7
/4
12'-2 3/8"
5' -2
/4
3'-0"
2' -9
/8
4'-6 7/8"
6 1/4"
6' -5
/4
8'-9 3/8"
5' -2
/4
3'-0"
7' -7
/8
12'-2 3/8"
2' -9
/8
8'-1 3/4"
1' -3
/8
7/
6 1/4"
4'-6 7/8"
2' -1
1/
2"
7' -1
3/
4"
8'-1 1/4"
9 7/8"
7' -7
/8
12'-2 3/8"
5' -2
/4
3'-0"
4' -6
/4
"6 5/8" 1'-3 5/8"
6 5/8"
5/
8"
1' -4
/8
1'-5 5/8" 6 5/8"
5/
8" 1'
-3
/8
1'-3 5/8" 6 5/8"
5/
8" 1'
-3
/8
6 5/8" 1'-4 1/8"
1' -5
/8
5/ 8"
6 5/8"
1'-4 1/8"
1' -5
/8
5/ 8"
1'-4 1/8"
5/
8" 1'
-0
/8
6 5/8" 1'-4 5/8"
'-2
/1
6"
9' -1
/1 6"
18'-1 1/2"
9'-11 5/8"
'-4
/8
23'-3 1/4"
3' -3
/4
7'-7 1/8"
8' -1
1/
8"
2'-1 1/8" 8'-2 7/8" 3 5/8"
7' -7
/4
5' -2
/4
12'-2 1/8"
3'-0"
4' -9
/4
8' -7
/8
3' -5
/8
2"
5'-2 1/4"3'-0 3/8"
3' -0
'-1
7'-7 3/8"
3/
5/
8" 1'
-2
/8
1'-1 7/8" 6 5/8"
'-1
/8
7'-7 1/8"
3' -0
5'-2 1/4" 5'-2 1/4"
'-1
/8
7'-7 1/8"
3' -0
'-2
/4
3' -0
" 5'-2 1/2"
7'-7 3/4"
5'-2 1/4"
7 13/16"1'-1 13/16"
/1 6"
7"
6' -7
/8
7' -7
/4
3'-0"
5' -2
/4
11'-3 7/8" 2"
5/
" 5 7/8"
5'-2 1/4"
3' -0
'-1
/4
7'-7 3/8"
1'-2 1/8"
1/
5'-2 1/4" 3'-2 3/8"
5'-2 1/4" 3'-1 7/8"
'-2
/8
3' -0
7'-7 1/4" 7'-7 1/4"7'-7 1/4" 7'-7 1/4"
'-2
/4
5'-2 1/4" 3'-9 1/8" 2'-7 1/8"
5'-2 1/4"
3/
3/
5/
8" 1'
-2
/8
6 5/8"
1'-9 1/4"
1' -3
/8
5/ 8"
6 5/8"
NOT IN SCOPE
NOT IN SCOPE
NOT IN SCOPE
6 5/8"
-2 1/2" -2 1/2" -2 1/2" -2 1/2"
-2 1/2"
-2 1/2"-2 1/2"-2 1/2"-2 1/2"-2 1/2"-2 1/2"
-2 1/2"
-2 1/2"
-2 1/2"
-3/4"
-3/4"
-1"
-3/4"
-3/4"
-2 1/2"
-2 1/2"
-2 1/2"
-2 1/2"-2 1/2"-2 1/2"
-2 1/2"-2 1/2"-2 1/2"-2 1/2"-2 1/2"-2 1/2"
-2 1/2"
-2 1/2" -2 1/2" -2 1/2" -2 1/2"
-3/4"
-8" BRICK LEDGE
RECESS AT NEW
PERIMETER
WALL, TYP.
-8" BRICK LEDGE RECESS AT
NEW PERIMETER WALL, TYP.
-8" BRICK LEDGE RECESS AT
NEW PERIMETER WALL, TYP.
-8" BRICK LEDGE RECESS AT
NEW PERIMETER WALL, TYP.
3' -4
8' -8
/1
6"
-8" BRICK LEDGE RECESS AT
NEW PERIMETER WALL, TYP.
M
L
1'-8 1/2"
-2 1/2"
'-3
/2
9'
-1
/2
'-0
/2
'-3
'-3
'-1
1/ 2"
'-7
/2
1'
-5
/2
4'
-6
'-0
4'
-1 0"
9' -1
0"
'-1
9' -3
5'
-3
6' -4
'-6
'-1
1/
2" 5'
-8
/2
5' -9
190'-5"
12'-0" 10'-0" 10'-0" 16'-6" 12'-6" 36'-0" 11'-0" 21'-6" 13'-0" 19'-6" 16'-3" 12'-2"
108C
114A 108B
103A
111109A
113A
108A
110E 110F
110D 110C
110B 110A
1B130
1B1251B141
1B142
1B124
1B1261B128
1B129
WAITING
CLEAN LINEN
SOILED UTL
GENERAL STOR
TEAM WORKRM
TEAM WORKRM
DEN
CORRIDOR
VESTIBULE
014A
RESIDENT - B2
BATH
175A
RESIDENT - B2
BATH
173A
MEDS
BATH
163A
BATH
161A
BATH
159A
BATH
158A
BATH
157A
BATH
156A
BATH
155A
RESIDENT - B1
RESIDENT - B1
BATH
153A
CORRIDOR
BATH
160A
BATH
162A
BATH
164A
DINING
166B
LIVING ROOM
166A
RESIDENT DINING
N&FS KITCHEN/
SERVERY
131A
CORRIDOR
CORRIDOR
DIR OFC
MED DIR OFC
H. LAUNDRY
BATHING RM
TLT
184A
TLT
176A
EQUIP STOR
CLEAN SUPPLY
NRS LDR OFC
SW OFC
178 HOUSE OFC
VESTIBULE
001A
PT/OT RECEP
100B
H. STOR
SSTV
131C
MOP
131B
HAC
RESIDENT - B1
RESIDENT - B1
RESIDENT - B1
RESIDENT - B2
RESIDENT - B2
RESIDENT - B2
RESIDENT - B2
RESIDENT - B2
RESIDENT - B2
CORRIDOR
OFFICE
1B103A
CONF. /
PRIVATE
DINING
TLT
ART ROOM
MP
STOR
132A
MULTIPURPOSE/
ACTIVITY
ROOM
132A
RT OFC
MED
HOUSE
STOR.
HOUSE
LNDRY
TOILET
117A
BATHING
ROOM
IT
ROOM
ELEC
FIRE RISER
ROOM
VESTIBULE
006A
RESIDENT
BARIATRIC
RESIDENT
RESIDENT
RESIDENT
RESIDENT
RESIDENT
RESIDENT
RESIDENT
RESIDENT
RESIDENT
LIVING
ROOM
133A
KITCHEN
DINING
133B
SOILED
UTILITY
HOUSE OFC
PANTRY
133C
CLEAN
SUPPLY
BATH
135A
BATH
134A
BATH
122A
BATH
121A
BATH
119A
BATH
136A
BATH
139A
BATH
140A
BATH
142A
BATH
143A
RESIDENT
RESIDENT
RESIDENT
BATH
138A
BATH
141A
BATH
137A
HAC
BATH
145A RESIDENT
RESIDENT
BATH
146A
STOR
DEN
STAFF
LOUNGE
RESIDENT
RESIDENT
CORRIDOR
BATH
151A
TLT
VESTIBULE
008A
CORRIDOR
BATH
152A th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
SPUR #: 2015
/5
/2
:3
:5
A
M
RECESS SLAB FLOOR PLAN
NR 010 OF 221DLK
BID DOCUMENTS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
GI018
N
3/32" = 1'-0"
LEVEL 1 - RECESS SLAB FLOOR PLAN1
LS-03
LS-03
LS-02
LS-02
LS-02
LS-03
LS-02
LS-02
LP-02
LS-03
LS-03
LS-02
LS-03
LS-02
LS-03
LP-02
LP-02
LS-02
LP-02
LS-03
LS-03
LS-03
LS-03
LS-03
LS-03
LP-02
INSTALL TREE PROTECTION
FENCING PRIOR TO CONSTRUCTION
EXISTING TREE TO REMAIN
DECORATIVE PAVERS
ON GRAVEL BASE
6' TALL FENCE
24' DIA SHADE STRUCTURE
(1) TABLE AND (4)CHAIRS
(6)ADIRONDACK CHAIRS
CIRCULAR PAVERS
ON GRAVEL BASE
(3) GAME TABLE
DECORATIVE PAVERS
ON GRAVEL BASE
WHISPER GLIDER SWING
12" CONCRETE EDGING
12" CONCRETE EDGING
LITTER RECEPTACLE
EXISTING WALKS
GATE
GATE
DECORATIVE PAVERS
ON CONCRETE BASE
PRICE OUT 4" CONCRETE
PAVEMENT IN LIEU OF
PAVERS. REFER CIVIL
FOR DETAIL.
STORAGE BENCH
HACKETT BEAM BOULDERS
DECOMPOSED GRANITE MULCH
12" CONCRETE EDGING
(4) BENCHES CENTERED BETWEEN COLUMNS
(1) TABLE AND (4)CHAIRS
(1) TABLE AND (3)CHAIRS
FLAGPOLE BASE, REFER CIVIL
FLAGPOLE BASE, REFER CIVIL
FLAGPOLE BASE, REFER CIVIL
ANTI RAM HACKETT BEAM BOULDERS
ALONG EAST SIDE OF COURTYARD
HACKETT BEAM BOULDERS
ANTI RAM HACKETT BEAM BOULDERS
ALONG EAST SIDE OF COURTYARD
BENCH
BERMUDA GRASS SOD
OUTDOOR STORAGE CABINET
PATIO FURNITURE SET
LITTER RECEPTACLE
PLANTING BED DRAINAGE
LS-02
LP-02
LP-02
LS-02
LS-03
LS-02
LP-02
LS-02
LP-02 12" CONCRETE EDGING
BERMUDA GRASS SOD SYMBOL DESCRIPTION QTY DETAIL
HACKETT BEAM BOULDERS - TYPE A - MINIMUM SIZE - 6`-7`
LONG X 30" WIDE - 3,500 LBS
HACKETT BEAM BOULDERS - TYPE B - APPROXIMATELY 5`-6`
LONG X 24" WIDE - 3,000 LBS
6/LP-02
6/LP-02
MATERIALS SCHEDULE
5/LS-02
5/LS-02
LS-01
HARDSCAPE PLAN
N O R T H
SCALE: 1 " = 10' - 0 "
0' 5' 10' 20'
SCALE: 1"=10'
HARDSCAPE PLAN1
LAYOUT NOTES
1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS, LAYOUT COORDINATES, AND
WORK FROM PREVIOUS AND ONGOING CONTRACTS IN THE FIELD. CONTRACTOR SHALL
REPORT ANY DISCREPANCIES TO THE LANDSCAPE ARCHITECT FOR DIRECTIONS
IMMEDIATELY BEFORE PROCEEDING WITH THAT PORTION OF THE WORK.
2. REFER TO CIVIL FOR DIMENSIONS OF HARDSCAPE ELEMENTS. CONTRACTOR SHALL
REQUEST A FIELD REVIEW BY THE LANDSCAPE ARCHITECT OF THE LAYOUT OF ALL
ELEMENTS, AS SHOWN. CONTRACTOR SHALL STAKE ALL LOCATIONS AND OBTAIN
APPROVAL FROM THE LANDSCAPE ARCHITECT PRIOR TO THE COMMENCEMENT OF
WORK.
3. CONTRACTOR SHALL ERECT AND INSTALL ALL WORK LEVEL, PLUMB, SQUARE, TRUE,
STRAIGHT, AND IN PROPER ALIGNMENT.
4. CONTRACTOR SHALL NOT SCALE DRAWINGS; CONTRACTOR SHALL USE DIMENSIONS
SHOWN.
5. NO DIMENSIONS ARE ADJUSTABLE WITHOUT THE REVIEW AND APPROVAL OF
LANDSCAPE ARCHITECT UNLESS NOTED.
6. TYPICAL [TYP] MEANS IDENTICAL FOR ALL SIMILAR CONDITIONS UNLESS OTHERWISE
NOTED.
7. ALIGN MEANS ACCURATELY LOCATE FINISH FACES IN THE SAME PLANE.
8. ALL CURVES FOR PAVING, BANDS, PATHS, AND EDGING SHALL BE ALIGNED IN A
SMOOTH AND CONTINUOUS FASHION AND SHALL MEET ADJACENT SURFACES AT 90
DEGREES, UNLESS OTHERWISE INDICATED. ALL WALK RADII AND CURVES SHALL BE
SMOOTH AND CONTINUOUS WITHOUT ABRUPT CHANGES OR BENDS UNLESS
OTHERWISE SHOWN.
9. MAX SPACING BETWEEN HACKETT BEAM ANTI RAM BOULDERS TO BE 48"
10. REFER MECHANICAL FOR CONNECTION TO STORM DRAIN IN THE INTERIOR COURTYARD.
CONTROLLED UNCLASSIFIED INFORMATION - CUI
VA PURCHASED, VA INSTALLED
VA PURCHASED, VA INSTALLED
VA PURCHASED, VA INSTALLED
VA PURCHASED, VA INSTALLED
VA PURCHASED, VA INSTALLED
VA PURCHASED, VA INSTALLED
VA PURCHASED, VA INSTALLED
VA PURCHASED, VA INSTALLED
VA PURCHASED, VA INSTALLED
VA PURCHASED, VA INSTALLED
VA PURCHASED, VA INSTALLED
VA PURCHASED, VA INSTALLED
NOTE:
REFER TO CIVIL FOR DIMENSIONS
OF HARDSCAPE ELEMENTS.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
Drawing Title
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
STAMP:
Veterans Health
Administration
Project Title
Location
Date Checked Drawn
Project Number
Drawing # OF
Drawing Number
Building Number
5/ /2 8:
:1
AM
CLS 222CLS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
SPUR #: 2015CONSULTANTS:
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
No. REVISION DESCRIPTION DATE
ARCH REG. NO. A-930 EXP. 12/31/2021
ENGR REG. NO. E-2586 EXP. 12/31/2021
FULLY SPRINKLERED
BID DOCUMENTS
09-06-23
6' TALL DECORATIVE FENCE
5/8" X 18GA PICKET
FENCE POST
16" X 11
4" MONTAGE RAIL
DOUBLE RING ADORNMENT
NOTES:
1. 4' TALL FENCE AND GATE TO BE MONTAGE PLUS FENCE WITH MAJESTIC TOP BY
AMERISTAR FENCE OR APPROVED EQUAL, WWW.AMERISTARFENCE.COM
2. CONTACT
2.1. MISTY SINGLETON (405)800-321-8724
2.2. WWW.AMERISTARFENCE.COM
3. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
4. COLOR TO BE BLACK
5. SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO ORDERING.
DOUBLE GATE ARRANGEMENT
2" CLR STANDARD
LEAF WIDTHS 2" CLR
2" CLR
3' -0
GATE UPRIGHT
2" 4'
-0
2' -0
5"
2"
8' O.C. NOM.
1'-0"
1'-0"
GATE POST
CANE BOLT
FINISHED GRADE
3,500 PSI CONCRETE FOOTING
NOT TO SCALE9
LS-02
HARDSCAPE DETAILS
COLORED CONCRETE PAVING
NOT TO SCALE
CONCRETE PAVING REFER
CIVIL
DECORATIVE CONCRETE
DECORATIVE CONCRETE NOTE:
1. COLOR ADDITIVE TO BE INTEGRAL TO THE FULL DEPTH OF
PAVEMENT AND TO BE BY DAVIS COLORS OR APPROVED EQUAL.
WWW.DAVISCOLORS.COM
4. COLOR AND TEXTURE BY BOMANITE OR APPROVED EQUAL.
(WWW.BOMANITE.COM)
5. TEXTURE TO BE REGULAR SLATE TEXTURE.
6. SUBMIT COLOR SAMPLES FOR APPROVAL.
FLUSH
1" M
IN
PAVERS ON CONCRETE BASE
NOT TO SCALE
1"
6"
CONCRETE PAVER
2 38" MIN. THICKNESS
CONCRETE BASE, REFER CIVIL
1" MIN. BEDDING SAND GEOTEXTILE
ADJACENT LANDSCAPE
#3 REBAR, CONTINUOUS
INSITU CONCRETE TOE
INSTALL WHERE PAVERS ABUT
LANDSCAPED AREAS
NOTE:
CONTRACTOR SHALL SUBMIT COLOR FOR APPROVAL.
COST OF CONCRETE TOE TO BE INCLUDED WITH PAVER ITEM.
ADJACENT CONCRETE
FRONT ELEVATION TOP VIEW
SECTION A-A
FOOT MOUNT
1.50"
2.96"
Ø0.50"
23.44"
.5
0"
3.50" 3.50"
81.57"61.89"
AA
1.
.1
2"
.1 6"
.0
4"
Ø 2.
24.00"
36" GAME TABLE - ANOVA
NOTE:
1. TABLE SHALL BE MODEL BH1801-GT BY ANOVA SITE FURNISHINGS OR
APPROVED EQUAL. WWW.ANOVAFURNISHINGS.COM
2. INCLUDE 24"X24" SQUARE INSET POLYCARBONATE GAME BOARD.
3. COLORS SHALL BE SELECTED BY ARCHITECT
4. INCLUDE SURFACE MOUNT OPTION
NOT TO SCALE7
NOTES:
1. 6' TALL FENCE AND GATE TO BE MONTAGE PLUS FENCE WITH MAJESTIC TOP BY
AMERISTAR FENCE OR APPROVED EQUAL, WWW.AMERISTARFENCE.COM
2. CONTACT
2.1. JASON GOINS (800)-321-8724
2.2. WWW.AMERISTARFENCE.COM
3. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
4. COLOR TO BE BLACK
FLUSH
1" M
IN
PAVERS ON GRAVEL BASE
NOT TO SCALE
1"
6"
CONCRETE PAVER
2 38" MIN. THICKNESS
4" COMPACTED
GRAVEL BASE
1" MIN. BEDDING SAND GEOTEXTILE
ADJACENT LANDSCAPE
#3 REBAR, CONTINUOUS
INSITU CONCRETE TOE
INSTALL WHERE PAVERS ABUT
LANDSCAPED AREAS
NOTE:
CONTRACTOR SHALL SUBMIT COLOR FOR APPROVAL.
COST OF CONCRETE TOE TO BE INCLUDED WITH PAVER ITEM.
ACCESSIBLE GLIDER
NOTE:
THERAPEUTIC SWING TO BE WHISPER GLIDE BY WHISPER GLIDE SWING CO, LLC
OR APPROVED EQUAL.
WWW.WHISPERGLIDE.COM
CONTACT : MATT RICHARDSON (800)944-7737
INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
NOT TO SCALE6
PAVER PATTERN - BERGERAC
STANDARD BERGERAC
PAVER CIRCLE KIT
INSTALL CAMBRIDGE
COBBLE PAVER TO
EXTEND THE RADIUS AS
SHOWN ON PLAN.
NOTE:
1. PAVERS TO BE BY BELGARD OR APPROVED EQUAL.
WWW.BELGARDCOMMERCIAL.COM
2. SUBMIT COLOR FOR APPROVAL PRIOR TO ORDERING
CONCRETE EDGING
OR INSITU
CONCRETE TOE
NOT TO SCALE4
6' -0
VA PURCHASED, VA INSTALLED VA PURCHASED, VA INSTALLED
TOP VIEW
FRONT VIEW
8' -0
C
LE
AR
'-3
1 2" R
EF
3' -0
R
EF
12'-0"
24'-0"
ISOMETRIC VIEW
TOP VIEW
FINISHED
GRADE
NOTE:
1. 24' SHADE STRUCTURE TO MATCH IMAGE, BY POLIGON, OR
APPROVED EQUAL.
2. WWW.POLIGON.COM
6. BASIS OF DESIGN TO BE OXFORD CLERESTORY - TWO
TIERED HEXAGON GAZEBO, HIP ROOF.
7. CONTACT JOHN MCMASTER WITH POLIGON SHELTERS.
1-(913)-907-0790
8. CONTRACTOR SHALL PROVIDE SEALED JOB SPECIFIC
ANCHOR AND FOOTING DESIGN DRAWINGS AND
ENGINEERED STRUCTURES FOR CONSTRUCTION.
9. SUBMIT COLOR SAMPLES FOR APPROVAL.
24' SHADE STRUCTURE - POLIGON
MOUNT LIGHT FIXTURES ON THE
INSIDE OF POSTS AT 7 FEET FROM
TOP OF CONCRETE SLAB.
REFER ELECTRICAL FOR TYPE OF
FIXTURE.
NOT TO SCALE10
NOTE:
BEAMS TO BE SET LEVEL IN ALL DIRECTIONS
FINISHED GRADE
HACKETT BEAM BOULDER
BY MINICK MATERIALS OR EQUAL
SIZE AS SPECIFIED ON PLAN
PREPARED SUBGRADE
4" COMPACTED
GRAVEL BASE
HACKETT BEAM BENCH ON GRAVEL BASE
DECORATIVE GRAVEL
REFER PLAN
1' -6
BURY APPROX. 13 OF
BEAM FOR
STABILIZATION
NOT TO SCALE5
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
Drawing Title
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
STAMP:
Veterans Health
Administration
Project Title
Location
Date Checked Drawn
Project Number
Drawing # OF
Drawing Number
Building Number
5/
/2
8:
:1
AM
CLS 221CLS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
SPUR #: 2015CONSULTANTS:
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
No. REVISION DESCRIPTION DATE
ARCH REG. NO. A-930 EXP. 12/31/2021
ENGR REG. NO. E-2586 EXP. 12/31/2021
FULLY SPRINKLERED
100% CONSTRUCTION DOCUMENTS
LS-03
HARDSCAPE DETAILS
NOTE:
1. BENCH TO BE MODEL PLK60T THERMORY PLANK ADIRONDACK CHAIR BY ANOVA SITE FURNISHINGS OR
APPROVED EQUAL, WWW.ANOVAFURNISHINGS.COM
2. CONTACT BOB EVANS, (314)-495-8357.
3. SUBMIT COLOR SAMPLES FOR APPROVAL PRIOR TO ORDERING.
4. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
FRONT ELEVATION
SIDE ELEVATION
20.00"
27.50" 32.57"
.1
3"
.1
4"
.7
8"
21.50"
36" ADIRONDACK CHAIR - ANOVA
1'-4"
NOT TO SCALE4
3.
5"
0.
3"
TOP VIEW SIDE ELEVATION
.3
5"
35.16"
2.
.4 8"
Ø52.58"
Ø1.64"
UMBRELLA HOLE
52" DIA TABLE - ANOVA
NOTE:
1. TABLE TO BE MODEL ELV52T - 52" DIA TABLE BY ANOVA SITE
FURNISHINGS OR APPROVED EQUAL,
WWW.ANOVAFURNISHINGS.COM
2. CONTACT CHRISTOPHER TORRES, (816)-602-4486.
3. SUBMIT COLOR SAMPLES FOR APPROVAL PRIOR TO ORDERING.
4. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
NOT TO SCALE2
FRONT ELEVATION SIDE ELEVATION BACK ELEVATION
25"
20"
24.12"
8"
22"
.5
9"
100°
24" CHAIR - ANOVA
NOTE:
1. CHAIR TO BE MODEL ELV60T - ELEVATION CHAIR BY ANOVA SITE
FURNISHINGS OR APPROVED EQUAL,
WWW.ANOVAFURNISHINGS.COM
2. CONTACT CHRISTOPHER TORRES, (816)-602-4486.
3. SUBMIT COLOR SAMPLES FOR APPROVAL PRIOR TO ORDERING.
4. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
NOT TO SCALE3
OUTDOOR STORAGE SHED
NOTE:
1. STORAGE CABINET TO BE 32 IN. W X 22 IN. D X 76 IN. H MEDIUM
BROWN CYPRESS VERTICAL SHED WITH DROP TABLE BY HOME
DEPOT OR APPROVED EQUAL. WWW.HOMEDEPOT.COM
2. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
NOT TO SCALE7
VA PURCHASED, VA INSTALLED VA PURCHASED, VA INSTALLED VA PURCHASED, VA INSTALLED
VA PURCHASED, VA INSTALLED
VA PURCHASED, VA INSTALLED
SIDE ELEVATIONFRONT ELEVATION
72" 66"
70.59"
.5
3"
22.74"
100°
8.
NOTE:
1. BENCH TO BE MODEL ELV80T - 6' ELEVATION BENCH BY ANOVA SITE
FURNISHINGS OR APPROVED EQUAL, WWW.ANOVAFURNISHINGS.COM
2. CONTACT CHRISTOPHER TORRES, (816)-602-4486.
3. SUBMIT COLOR SAMPLES FOR APPROVAL PRIOR TO ORDERING.
4. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
6' BENCH - ANOVA
NOT TO SCALE5
OUTDOOR STORAGE BENCH
NOTE:
1. STORAGE BENCH TO BE MERANTI 51 INCH TEAK OIL WOOD
OUTDOOR STORAGE BENCH OR APPROVED EQUAL.
WWW.HOMEDEPOT.COM
2. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
NOT TO SCALE8 VA PURCHASED, VA INSTALLED
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
Drawing Title
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
STAMP:
Veterans Health
Administration
Project Title
Location
Date Checked Drawn
Project Number
Drawing # OF
Drawing Number
Building Number
5/
/2
8:
:1
AM
CLS 221CLS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
SPUR #: 2015CONSULTANTS:
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
No. REVISION DESCRIPTION DATE
ARCH REG. NO. A-930 EXP. 12/31/2021
ENGR REG. NO. E-2586 EXP. 12/31/2021
FULLY SPRINKLERED
100% CONSTRUCTION DOCUMENTS
09-06-23
SIDE ELEVATION FRONT ELEVATION
TOP VIEW
24" 23.13"
9.
.4 9"
.1
3"
44.46"
20.55"
90°
28" 15.37"
7.16"
.7
3" 3.
26.7"
LITTER RECEPTACLE - ANOVA
NOTE:
1. LITTER RECEPTACLE TO BE MODEL ELV45T BY ANOVA SITE
FURNISHINGS OR APPROVED EQUAL,
WWW.ANOVAFURNISHINGS.COM
2. CONTACT CHRISTOPHER TORRES, (816)-602-4486.
3. SUBMIT COLOR SAMPLES FOR APPROVAL PRIOR TO ORDERING.
4. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
NOT TO SCALE6
FLUSH
1" M
IN
PAVERS ADJACENT TO BUILDING
NOT TO SCALE
1"
6"
CONCRETE PAVER
2 38" MIN. THICKNESS
CONCRETE BASE, REFER CIVIL
1" MIN. BEDDING SAND GEOTEXTILE
ADJACENT LANDSCAPE
#3 REBAR, CONTINUOUS
INSITU CONCRETE TOE
INSTALL WHERE PAVERS ABUT
LANDSCAPED AREAS
NOTE:
CONTRACTOR SHALL SUBMIT COLOR FOR APPROVAL.
COST OF CONCRETE TOE TO BE INCLUDED WITH PAVER ITEM.
BUILDING THRESHOLD
PLANTING BEDS WITH MULCH
PLANTING BEDS WITH MULCH
PLANTING BEDS WITH MULCH
LP-02
LP-02
LP-02
PLANTING BED
LP-02
SOD DISTURBED AREAS
BERMUDA GRASS SOD
BERMUDA GRASS SOD
LP-02
LP-02
PLANTING BED
PLANTING BED
PLANTING BEDS
PLANTING BED DRAINAGE
PLANTING BED DRAINAGE
LP-02
LP-02
LP-02
LP-01
LANDSCAPE PLAN
N O R T H
SCALE: 1 " = 10' - 0 "
0' 5' 10' 20'
SCALE: 1"=10'
LANDSCAPE PLAN1
SCALE: 1"=10'
LANDSCAPE PLAN INTERIOR COURTYARD2
N O R T H
SCALE: 1 " = 10' - 0 "
0' 5' 10' 20'
NOTE:
REFER TO CIVIL FOR DIMENSIONS
OF HARDSCAPE ELEMENTS.
GENERAL NOTES:
1. CONTRACTOR SHALL BE FAMILIAR WITH ALL EXISTING SITE CONDITIONS AND UNDERGROUND UTILITIES, PIPES, AND STRUCTURES. CONTRACTOR SHALL BE RESPONSIBLE FOR BODILY INJURY AND/OR ANY COST INCURRED DUE TO DAMAGE OF OWNER'S PROPERTY OR SAID UTILITIES. CONTRACTOR SHALL HAND DIG FOOTINGS, PLANTING BEDS, ETC. AS REQUIRED. CONTRACTOR IS RESPONSIBLE FOR CONTACTING UTILITY COMPANIES PRIOR TO ANY EXCAVATION.
2. ANY CONFLICTING INFORMATION SHALL BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT OR THE LANDSCAPE ARCHITECT SHALL ASSUME
THAT THE CONTRACTOR HAS INCORPORATED THE SPECIFIED ITEM.
3. DO NOT WILLFULLY PROCEED WITH CONSTRUCTION OF DESIGN WHEN UNKNOWN OBSTRUCTIONS AND/OR GRADE DIFFERENCES EXIST THAT MAY NOT HAVE BEEN KNOWN DURING DESIGN. SUCH CONDITIONS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT. THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ALL NECESSARY REVISIONS DUE TO FAILURE TO GIVE SUCH NOTIFICATION.
4. CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT 48 HOURS PRIOR TO COMMENCEMENT OF WORK TO COORDINATE PROJECT INSPECTION SCHEDULES.
CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, AND SERVICES NECESSARY TO PROVIDE ALL WORK. WORK TO BE COMPLETE IN PLACE
AS SPECIFIED.
5. ALL MATERIALS SHALL BE OF STANDARD, APPROVED AND FIRST GRADE QUALITY AND SHALL BE IN PRIME CONDITION WHEN ACCEPTED AND INSTALLED. ANY COMMERCIALLY PROCESSED OR PACKAGED MATERIAL SHALL BE DELIVERED TO THE SITE IN THE ORIGINAL UNOPENED PACKAGING BEARING THE
MANUFACTURER'S GUARANTEED ANALYSIS.
6. ADD 2" MIN. DECOMPOSED, STABLE, WEED FREE ORGANIC COMPOST TO ALL PLANTING BEDS AND TILL IN TO A DEPTH OF 6-8". THEN RAKE SOIL SMOOTH
PRIOR TO PLANTING.
7. MULCH ALL PLANTING AREAS WITH 3" MINIMUM GRADE A SHREDDED CEDAR BARK MULCH. COLOR TO BE DARK BROWN.
8. APPLY NON-SELECTIVE SYSTEMIC HERBICIDE (ROUND-UP OR EQUIVALENT) TO KILL ALL LIVE PLANT MATERIAL IN BEDS BEFORE PLANTING AND BEFORE
ADDING MULCH. APPLY PRE-EMERGENT HERBICIDE TO BED AREAS AFTER PLANTING.
9. IN ALL DISTURBED LAWN AREAS AND AS SHOWN, INSTALL U-3 BERMUDA SOD, CYNODON DACTYLON 'U-3'.
10. ALL LAWN AND PLANTING AREAS SHALL SLOPE TO DRAIN A MINIMUM OF 2% POSITIVE DRAINAGE UNLESS OTHERWISE NOTED. CONTRACTOR SHALL BE
RESPONSIBLE AND BEAR COSTS OF RE-LANDSCAPING FOR GRADES.
11. REFER TO SHEET LP-02 FOR PLANTING DETAILS/INSTRUCTIONS.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
Drawing Title
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
STAMP:
Veterans Health
Administration
Project Title
Location
Date Checked Drawn
Project Number
Drawing # OF
Drawing Number
Building Number
5/
/2
8:
:1
AM
CLS 222CLS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
SPUR #: 2015CONSULTANTS:
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
No. REVISION DESCRIPTION DATE
ARCH REG. NO. A-930 EXP. 12/31/2021
ENGR REG. NO. E-2586 EXP. 12/31/2021
FULLY SPRINKLERED
LP-02
LANDSCAPE DETAILS
MOWSTRIP, CURB,
OR SIDEWALK
SOD AS SPECIFIED
TIGHT BEVELED JOINTS
1"
2"
AMENDED SOIL
ADD 2" OF TOPSOIL AND TILL INTO THE TOP 2" OF EXISTING
SOIL FOR A TOTAL DEPTH OF 4" OF AMENDED SOIL
SOD INSTALLATION
NOT TO SCALE
SOD NOTES:
1. SOD TO BE CYNODON DACTYLON 'U-3' BERMUDA UNLESS OTHERWISE NOTED.
2. ADD 2" OF TOPSOIL AND TILL INTO THE TOP 2" OF EXISTING SOIL FOR A TOTAL
DEPTH OF 4" OF AMENDED SOIL
3. LAY SOD WITHIN 24 HOURS OF HARVESTING.
4. FINISH GRADE AND RAKE LAWN AREAS BEFORE SODDING TO CREATE A
SMOOTH SURFACE FREE OF BUMPS AND RUTS.
5. BUTT ENDS AND SIDES OF SOD TOGETHER TO FORM SOLID MASS WITH
TIGHTLY FITTED JOINTS.
6. STAGGER SOD STRIPS OR PADS TO OFFSET JOINTS IN ADJACENT COURSES.
7. TAMP AND ROLL LIGHTLY TO ENSURE GOOD CONTACT WITH SUBGRADE,
ELIMINATE AIR POCKETS, AND CREATE A SMOOTH SURFACE.
8. LAY SOD ACROSS ANGLE OF SLOPES GREATER THAN 1:3. ANCHORS MUST BE
USED FOR SLOPES GREATER THAN 1:2.
9. WORK SOIL OR FINE SAND INTO MINOR CRACKS BETWEEN PIECES OF SOD.
10. CUT SOD NEXT TO PAVED SURFACES IN A STRAIGHT LINE TO ENSURE A NEAT
FINISHED LOOK.
11. SATURATE SOD WITH FINE WATER SPRAY WITHIN TWO HOURS OF PLANTING.
NOTES:
1. ADD CONTROL JOINTS @ 5' O.C. MIN.
2. ADD EXPANSION JOINTS EVERY 10 CONTROL JOINTS, AT CORNERS AND WHEN
ABUTTING CURBS, WALKS, FOOTINGS OR STRUCTURES.
4. TAPER EDGING TO BE FLUSH WITH FINISHED GRADE ADJACENT TO PAVING OR CURBS.
5. OBTAIN APPROVAL FROM LANDSCAPE ARCHITECT OF FINAL CONCRETE EDGING LAYOUT
PRIOR TO POURING CONCRETE
CONCRETE EDGING 6"X12"
NOT TO SCALE
STIFF BROOM FINISH
4" ROUNDED EDGE
2- #4 REBAR CONTINUOUS
GRADE
3500 PSI CONCRETE
TOP OF CONCRETE BAND
SHALL BE 2" ABOVE GRADE
TO ALLOW FOR MULCH
MULCH
4"
12"
6"
FENCE FOOTING BEYOND
FENCE POST BEYOND
GRAVEL MULCH REFER PLAN
3IN. DEPTH
CURB, SIDEWALK, OR
CONCRETE EDGING
NATIVE SOIL OR SELECT FILL
2" BELOW ADJACENT
PAVING, CURB, SIDEWALK,
OR CONCRETE EDGING
NON WOVEN FILTER FABRIC (3 O.Z. / SY)
- TO EXTEND TO CONCRETE. PROVIDE 6"
MIN. OVERLAP WHERE EDGES JOIN
GRAVEL MULCH - 3" DEEP
NOT TO SCALE
NOTE:
BEAMS TO BE SET LEVEL IN ALL DIRECTIONS
FINISHED GRADE
HACKETT BEAM BOULDER
BY MINICK MATERIALS OR EQUAL
SIZE AS SPECIFIED ON PLAN
PREPARED SUBGRADE
4" COMPACTED
DECORATIVE GRAVEL
BOULDER ON GRAVEL BASE
4"
NOT TO SCALE6
HACKETT BEAM ANTI RAM
BOULDERS TYP
CONTROLLED UNCLASSIFIED INFORMATION - CUI
NOTES:
1. WHERE PLANTING BED ABUTS A BUILDING SLOPE AWAY FROM BUILDING AT 2% MIN SLOPE
PREPARE SOIL IN
THE ENTIRE
BED AS REQUIRED.
PREPARE SOIL FOR SHRUBS
18" DEEP. (FOR LARGER
SHRUB ROOTBALLS, MAKE
DEPTH MIN. 4" DEEPER THAN BALL)
CROWN BEDS TO PROVIDE
POSITIVE DRAINAGE.
3" MULCH
PAVING
EXISTING SUBGRADE OR
BACKFILL SOIL
SCARIFY TO 4-6" TO BIND WITH
NEW SOIL
PLANTING BED PREPARATION
NOT TO SCALE2
PLANTING BED WIDTH VARIES
3" SPECIFIED MULCH
18" SOIL BACKFILL
NO 57 AGGREGATE MIN 12" X 12"
6" AGGREGATE REQUIRED BELOW AND ON
EITHER SIDE OF DRAIN PIPE
4" PERFORATED DRAIN PIPE
3 O.Z./S.Y FILTER FABRIC WRAP COMPLETELY
AROUND AGGREGATE OVERLAPPING ON TOP
FINISHED GRADE
PLANTING BED DRAINAGE
NOT TO SCALE7
NOTES:
1. TREE PROTECTION ZONE REQUIRED AS SHOWN ON PLANS AND WHERE CONSTRUCTION
OPERATIONS MUST TAKE PLACE WITHIN 30' OF EXISTING TREES NOTED TO BE PROTECTED.
2. MAINTAIN BARRIER AT ALL TIMES.
3. SECURELY ATTACH ORANGE VINYL CONSTRUCTION FENCING.
4. REMOVE POSTS AND FENCING AT COMPLETION OF THE PROJECT OR WHEN DIRECTED BY
THE OWNER.
4'
WITHIN TREE PROTECTION
AREA, RETAIN EXISTING
VEGETATION OR APPLY 4"
MULCH.
ORANGE VINYL CONSTRUCTION
FENCING
INSTALL FENCING THE DISTANCE
OF THE DIAMETER OF TREE
CROWN, OR AS SHOWN
6' T-POST BURIED 2' @ 8' O.C.
TREE PROTECTION - ORANGE VINYL
NOT TO SCALE1
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
Drawing Title
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma…
This is the start of the file's text. The full file is on GovTribe.