Attachment 2a Combined Drawings Construct Addition and Renovated Bldg 60.pdf

PDF 21 MB Posted

Attached to
Y1DA--589-703 Construct Addition and Renovate Community Living Center, Building 60 (VA-24-00028736)
Solicitation number
36C77624B0019
Issued by

About this file

The provided document is a set of Combined Drawings for the "Construct Addition and Renovated Bldg 60" project, associated with the federal contract opportunity "Y1DA--589-703 Construct Addition and Renovate Community Living Center, Building 60 (VA-24-00028736)". The solicitation number is 36C77624B0019, and the procuring agency is the Department of Veterans Affairs Technology Acquisition Center Austin. The project involves the construction of an addition and renovation of Building 60, a Community Living Center. The drawings provide detailed specifications and technical requirements for the construction and renovation work.

View the file

Other files

File Type Posted
36C77624B0019 0003.pdf PDF
0002 Attachment 4 Bldg 60 Asbestos Survey.pdf PDF
0002 Attachment 3 DBA Wage Determination Sedgewick 20240906.pdf PDF
0002 Attachment 2 589-703 Bldg. 60 Site Visit Sign-in Sheet.pdf PDF
0002 Attachment 1 Technical Questions Received Responses.docx DOCX document
36C77624B0019 0002.pdf PDF
0001 Attachment 2i Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
0001 Attachment 2c Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
0001 Attachment 2h Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
0001 Attachment 2a Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
0001 Attachment 2g Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
0001 Attachment 2b Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
0001 Attachment 2d Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
0001 Attachment 2f Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
0001 Attachment 2e Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
36C77624B0019 0001.pdf PDF
Attachment 1 FINAL SPECS Construct Addition and Renovate Bldg 60.pdf PDF
Attachment 2e Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
Attachment 4 Limitations on Subcontracting - Construction.docx DOCX document
Attachment 2i Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
Attachment 2h Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
Attachment 2c Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
Attachment 2b Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
Attachment 2f Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
FINAL SPECS Attachment 2 Geotech Report.pdf PDF
Attachment 2g Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
Attachment 3 DBA Wage Determination Sedgwick - 20240522.pdf PDF
Attachment 2d Combined Drawings Construct Addition and Renovated Bldg 60.pdf PDF
36C77624B0019_1.docx DOCX document
Attachment 5 Division Cost Breakdown - 5-29-24.xlsx XLSX spreadsheet
FINAL SPECS Attachment 1 Contract Documents Addendum 01.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing #

U.S. DEPARTMENT OF VETERANS AFFAIRS

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. A-930 EXP. 12/31/2023

ENGR REG. NO. E-2586 EXP. 12/31/2023

STRUCTURAL/CIVIL

ENGINEER

H2B

1225 N. LOOP W #800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH

ENGINEER

SPUR DESIGN

11020 KING STREET, STE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

LANDSCAPE ARCHITECT

CLS & ASSOCIATES

825 N. BROADWAY AVE, STE 315

OKLAHOMA, OK 73102

(405) 525-2220

HEALTHCARE/MED

EQUIPMENT PLANNER

INNOVA GROUP

3196 N. SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT SECURITY

CONSULTANTS,

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

FOOD & BEVERAGE

PLANNER

STURM CONSULTING

5838 S. HUDSON PLACE

TULSA, OK 74135

(918) 260-0667

ENVIRONMENTAL

ENGINEER

RIVERFRONT ENVIRONMENTAL

1139 OLIVE STREET, STE 300

ST. LOUIS, MO 63101

(314) 436-9492

SPUR #: 2015

/5

/2

:3

:4

A

M

COVER SHEET

NR 001 OF 229DLK

BID DOCUMENTS

ADDITION AND RENOVATION OF CLC

VA PROJECT NUMBER: 589-703

ADDITION AND RENOVATION

OF CLC

09/06/2023

589-703

ROBERT J. DOLE VA MEDICAL CENTER

5500 EAST KELLOGG, BLDG. 60

WICHITA, KS 67218

ROBERT J. DOLE VA MEDICAL CENTER

5500 EAST KELLOGG, BLDG. 60

WICHITA, KS 67218

BID DOCUMENTS

G-000

SHEET INDEX

SEQUENCE NUMBER SHEET NAME

[01] GENERAL

001 G-000 COVER SHEET

002 GI001 GENERAL INFORMATION

003 GI011 PHASING PLANS

004 GI012 PHASING PLANS

005 GI013 OCCUPANCY PLAN - AREA A

006 GI014 OCCUPANCY PLAN - AREA B

007 GI015 INTERIM LIFE SAFETY PLAN

008 GI016 LIFE SAFETY PLAN - AREA A

009 GI017 LIFE SAFETY PLAN - AREA B

010 GI018 RECESS SLAB FLOOR PLAN

[02] LANDSCAPE

011 LS-01 HARDSCAPE PLAN

012 LS-02 HARDSCAPE DETAILS

013 LS-03 HARDSCAPE DETAILS

014 LP-01 LANDSCAPE PLAN

015 LP-02 LANDSCAPE DETAILS

016 LI-01 IRRIGATION PLAN

017 LI-02 IRRIGATION DETAILS

[03] CIVIL

018 CS000 TOPOGRAPHIC SURVEY

019 CS100 OVERALL LAYOUT

020 CS101 SITE LAYOUT

021 CS102 DEMOLITION LAYOUT

022 CS103 ENLARGED SITE LAYOUT (1 OF 2)

023 CS104 ENLARGED SITE LAYOUT (2 OF 2)

024 CS105 ENLARGED GRADING LAYOUT (1 OF 2)

025 CS106 ENLARGED GRADING LAYOUT (2 OF 2)

026 CS107 DRAINAGE AREA MAP LAYOUT

027 CS108 DRAINAGE AREA MAP CALCULATIONS

028 CS109 UTILITY LAYOUT

029 CS110 STORM WATER POLLUTION PREVENTION PLAN

030 CS111 PLAN AND PROFILE (1 OF 2)

031 CS112 PLAN AND PROFILE (2 OF 2)

032 CS200 PAVEMENT AND DRAINAGE DETAILS

033 CS201 SANITARY SEWER DETAILS

034 CS202 WATER LINE DETIALS

035 CS203 SWPPP DETAILS

036 CS204 MISCELLANEOUS DETAILS

[04] STRUCTURAL

037 SA001 STRUCTURAL GENERAL NOTES

038 SA002 STRUCTURAL GENERAL NOTES

039 SA010 STRUCTURAL SPECIAL INSPECTIONS

040 SA011 STRUCTURAL SPECIAL INSPECTIONS

041 SA030 TYPICAL DETAILS - CONCRETE

042 SA031 TYPICAL DETAILS - CONCRETE

043 SA050 TYPICAL DETAILS - STEEL

044 SA051 TYPICAL DETAILS - STEEL

045 SD101 STRUCTURAL DEMOLITION SITE PLAN

046 SD102 STRUCTURAL DEMOLITION FRAMING PLAN

047 SB100 OVERALL PLAN

048 SB101 FOUNDATION PLAN

049 SB102 PARTIAL EXISTING FOUNDATION PLAN

050 SB401 ENLARGED PLANS

051 SB501 FOUNDATION DETAILS

052 SB502 FOUNDATION DETAILS

053 SF101 ROOF FRAMING PLAN

054 SF102 PARTIAL EXISTING ROOF FRAMING PLAN

055 SF103 PENTHOUSE - ROOF FRAMING PLAN

056 SF501 FLOOR FRAMING DETAILS

057 SF504 ROOF FRAMING DETAILS

058 SF505 STRUCTURAL FRAMING DETAILS

059 SF506 STRUCTURAL FRAMING DETAILS

[05] ENVIRONMENTAL

060 HA001 ENVIRONMENTAL GENERAL NOTES

061 HA100 ENVIRONMENTAL HAZARDS - GROUND FLOOR

062 HA200 ENVIRONMENTAL HAZARDS - ROOF

[06] ARCHITECTURAL

063 AS001 ARCHITECTURAL DEMOLITION SITE PLAN

064 AS010 ARCHITECTURAL NEW SITE PLAN

065 AD010 DEMOLITION PLAN

066 AD011 DEMOLITION PLAN

067 AD102 DEMOLITION REFLECTED CEILING PLAN

068 AE021 PARTITION TYPES AND DETAILS

069 AE101 OVERALL FLOOR PLAN

070 AE111 REFERENCE PLAN - AREA A

071 AE112 REFERENCE PLAN - AREA B

072 AE113 DIMENSION PLAN - AREA A

073 AE114 DIMENSION PLAN - AREA B

074 AE120 ROOF PLAN

075 AE121 PENTHOUSE PLANS

076 AC131 REFLECTED CEILING PLAN - AREA A

DEDUCT ALTERNATES

N

AREA

PLAN

LOCATION

PLAN

N

PROJECT LOCATION

BUILDING 60

1. REMOVE CASEWORK IN RESIDENT ROOMS (#119, #121, #122, #134, #135, #136, #137, #138, #139, #140, #141, #142, #143, #145, #146, #151, #152, #153, #155, #156, #157, #158, #159, #160, #161, #162, #163, #164, #173 & #175).

2. REMOVE CASEWORK AND FINAL FINISHES IN THE FOLLOWING SPACES: #130 - CONFRENCE ROOM, # 128 - ART ROOM, #144 DEN, #132 MULTIPURPOSE ROOM, AND #132A - MULTIPURPOSE ROOM STORAGE.

REMOVE CASEWORK AT THE NURSING STATION (#123 & #167) AND PANTRY KITCHENS (#133 & #166).

3. REMOVE SECURITY GATE AT THE BACK OF THE BUILDING. THIS IS LOCATED NORTH OF THE NEW

BUILDING EXPANSION. THIS ALSO INCLUDES THE SENSOR, NEW CONCRETE, AND CURBS.

4. REMOVE MEDICAL GAS AND VACUUM FROM DESIGN.

SHEET INDEX

SEQUENCE NUMBER SHEET NAME

077 AC132 REFLECTED CEILING PLAN - AREA B

078 AC133 ENLARGED REFLECTED CEILING PLANS - AREA A

079 AC134 ENLARGED REFLECTED CEILING PLANS - AREA B

080 AE201 BUILDING ELEVATIONS

081 AE202 BUILDING ELEVATIONS

082 AE203 BUILDING ELEVATIONS

083 AE301 BUILDING SECTIONS

084 AE302 BUILDING SECTIONS

085 AE303 BUILDING SECTIONS

086 AE311 WALL SECTIONS

087 AE312 WALL SECTIONS

088 AE313 WALL SECTIONS

089 AE401 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA A

090 AE402 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA A

091 AE403 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA A

092 AE404 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA A

093 AE405 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA A

094 AE406 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA A

095 AE407 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA B

096 AE408 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA B

097 AE409 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA B

098 AE410 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA B

099 AE411 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA B

100 AE412 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA B

101 AE413 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA B

102 AE414 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA B

103 AE415 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA B

104 AE416 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA B

105 AE417 INTERIOR ELEVATIONS & ENLARGED PLANS - AREA B

106 AE421 SECTION DETAILS

107 AE451 PLAN DETAILS

108 AE452 PLAN DETAILS

109 AE453 PLAN DETAILS

110 AE454 PLAN DETAILS

111 AE501 CEILING DETAILS

112 AE601 DOOR AND WINDOW SCHEDULES

113 AE610 DOOR AND WINDOW DETAILS

114 AE611 DOOR AND WINDOW DETAILS

115 AF701 FINISH FLOOR PLANS - AREA A

116 AF702 FINISH FLOOR PLANS - AREA B

117 AF711 FINISH SCHEDULE AND FINISH LEGEND

118 AF712 INTERIOR DETAILS

119 AF901 MILLWORK DETAILS

120 AF902 MILLWORK DETAILS

121 AI722 3D INTERIOR VIEWS

122 AQ801 EQUIPMENT PLAN - AREA A

123 AQ802 EQUIPMENT PLAN - AREA B

124 AW950 SIGNAGE PLAN - AREA A

125 AW951 SIGNAGE PLAN - AREA B

[07] FIRE PROTECTION

126 FA001 FIRE ALARM GENERAL NOTES, LEGEND, AND DIAGRAMS

127 FA101 FIRE ALARM AUDIBILITY GROUND FLOOR PLAN

128 FA102 FIRE ALARM PLAN - AREA A

129 FA103 FIRE ALARM PLAN - AREA B

130 FX101 FIRE SUPPRESSION HAZARD CLASSIFICATION GROUND FLOOR

[08] PLUMBING

131 P-000 PLUMBING LEGEND

132 PD101 PLUMBING WASTE DEMOLITION PLAN

133 PD102 PLUMBING SUPPLY DEMOLITION PLAN

134 PD103 PLUMBING MEDICAL GAS DEMOLITION PLAN

135 PD104 PENTHOUSE PLUMBING DEMOLITION PLAN

136 PP101 PLUMBING SUPPLY PLAN - AREA A

137 PP102 PLUMBING SUPPLY PLAN - AREA B

138 PP401 PLUMBING SUPPLY ENLARGED PLANS

139 PL101 PLUMBING WASTE UNDERGROUND PLAN - AREA A

140 PL102 PLUMBING WASTE UNDERGROUND PLAN - AREA B

141 PL103 PLUMBING WASTE PLAN - AREA A

142 PL104 PLUMBING WASTE PLAN - AREA B

143 PL105 PLUMBING ROOF PLAN - AREA A

144 PL106 PLUMBING ROOF PLAN - AREA B

145 PG101 PLUMBING MEDICAL GAS PLAN - AREA A

146 PG102 PLUMBING MEDICAL GAS PLAN - AREA B

147 PS201 NATURAL GAS CONNECTION PLAN

148 PS202 NATURAL GAS ENLARGED PLANS

149 P-301 PLUMBING RISER SUPPLY DIAGRAM

150 P-302 DRAIN WASTE VENT RISER - AREA A

151 P-303 DRAIN WASTE VENT RISER - AREA B

152 P-304 MEDICAL GAS RISER

153 P-401 PLUMBING PENTHOUSE PLAN

154 P-501 PLUMBING DETAILS

155 P-502 PLUMBING DETAILS

156 P-601 PLUMBING SCHEDULES

SHEET INDEX

SEQUENCE NUMBER SHEET NAME

[09] MECHANICAL

157 M-000 LEGEND AND ABBREVIATIONS

158 MT101 MECHANICAL TEMPORARY PLAN

159 MD101 MECHANICAL HVAC DEMOLITION PLAN

160 MD102 MECHANICAL PIPING DEMOLITION PLAN

161 MD103 MECHANICAL ROOF DEMOLITION PLAN

162 MD104 MECHANCIAL PENTHOUSE DEMOLITION PLAN

163 MH101 MECHANICAL HVAC DUCT PLAN - AREA A

164 MH102 MECHANICAL HVAC DUCT PLAN - AREA B

165 MH103 MECHANICAL ROOF PLAN

166 MH131 MECHANICAL HVAC AIRFLOW PLAN - AREA A

167 MH132 MECHANICAL HVAC AIRFLOW PLAN - AREA B

168 MP101 MECHANICAL HVAC PIPING PLAN - AREA A

169 MP102 MECHANICAL HVAC PIPING PLAN - AREA B

170 M-201 MECHANICAL FLOW DIAGRAMS

171 M-301 MECHANICAL SECTIONS

172 M-401 MECHANICAL PENTHOUSE ENLARGED PLANS

173 M-402 MECHANICAL UTILITY YARD PLAN

174 M-501 MECHANICAL DETAILS

175 M-502 MECHANICAL DETAILS

176 M-503 MECHANICAL DETAILS

177 M-504 MECHANICAL DETAILS

178 M-601 MECHANICAL SCHEDULES

179 M-602 MECHANICAL SCHEDULES

180 M-701 MECHANICAL CONTROLS

181 M-702 MECHANICAL CONTROLS

182 M-703 MECHANICAL CONTROLS

183 M-704 MECHANICAL CONTROLS

184 M-705 MECHANICAL CONTROLS

[10] ELECTRICAL

185 E-001 ELECTRICAL SYMBOLS & ABBREVIATIONS

186 ES101 ELECTRICAL OVERALL SITE PLAN

187 ES102 ELECTRICAL PARTIAL SITE PLANS

188 ED101 ELECTRICAL POWER DEMOLITION PLAN

189 ED102 ELECTRICAL LIGHTING DEMOLITION PLAN

190 ED103 ELECTRICAL ROOF DEMOLITION PLAN

191 EP101 ELECTRICAL POWER PLAN - AREA A

192 EP102 ELECTRICAL POWER PLAN - AREA B

193 EL201 ELECTRICAL LIGHTING PLAN - AREA A

194 EL202 ELECTRICAL LIGHTING PLAN - AREA B

195 EQ101 MECHANICAL COORDINATION POWER PLAN - AREA A

196 EQ102 MECHANICAL COORDINATION POWER PLAN - AREA B

197 EQ103 MECHANICAL COORDINATION POWER PLAN - ROOF

198 EQ104 ELECTRICAL LIGHTING PROTECTION PLAN

199 EP401 ELECTRICA UTILITY YARD AND ELECTRICAL ROOM PLANS

200 E-501 ELECTRICAL AND LIGHTING PROTECTION SYSTEM DETAILS

201 E-502 ELECTRICAL DETAILS

202 E-503 LIGHTING DETAILS

203 E-601 ELECTRICAL ONE-LINE DIAGRAM - DEMOLITION

204 E-602 ELECTRICALONE-LINE DIAGRAM - NEW WORK

205 E-603 ELECTRICAL PANEL SCHEDULES - EXISTING

206 E-604 ELECTRICAL PANEL SCHEDULES - NEW WORK

207 E-605 ELECTRICAL PANEL SCHEDULES - NEW WORK

208 E-606 LIGHTING SCHEDULES

[11] TECHNOLOGY

209 T-000 TECHNOLOGY SYMBOLS & ABBREVIATIONS

210 TS101 TECHNOLOGY SITE PLAN

211 TS102 TECHNOLOGY SITE FIBER ROUTING PLAN

212 TD101 TECHNOLOGY DEMOLITION PLAN

213 TN201 TECHNOLOGY TELECOMMUNICATIONS PLAN - AREA A

214 TN202 TECHNOLOGY TELECOMMUNICATIONS PLAN - AREA B

215 TY301 TECHNOLOGY SECURITY PLAN - AREA A

216 TY302 TECHNOLOGY SECURITY PLAN - AREA B

217 T-401 TECHNOLOGY DETAILS

218 T-402 TECHNOLOGY DETAILS

219 T-501 TECHNOLOGY RISER DIAGRAMS

[12] FOOD SERVICE

220 FS1.1 FOOD SERVICE EQUIPMENT ARRANGEMENT PLAN

221 FS1.2 FOOD SERVICE EQUIPMENT ELEVATIONS

222 FS2.1 FOOD SERVICE EQUIPMENT SPECIAL CONDITIONS PLAN

223 FS3.1 FOOD SERVICE EQUIPMENT PLUMBING CONNECTIONS PLAN

224 FS4.1 FOOD SERVICE EQUIPMENT ELECTRICAL CONNECTIONS PLAN

225 FS5.1 FOOD SERVICE EQUIPMENT VENTILATOR PLAN

226 FS5.2 FOOD SERVICE EQUIPMENT VENTILATOR PLAN

227 FS5.3 FOOD SERVICE EQUIPMENT VENTILATOR PLAN

228 FS5.4 FOOD SERVICE EQUIPMENT VENTILATOR PLAN

229 FS6.1 FOOD SERVICE EQUIPMENT SNEEZE GUARD PLAN

TOTAL SHEETS: 229

No. REVISION DESCRIPTION DATE

CODES STANDARDS AND EXECUTIVE ORDERS

ASHRAE 90.1 - 2019 EDITION

BUILDING LOCATION: WICHITA, KS

CLIMATE ZONE (TABLE ANNEX 1-1): ZONE 4A

INTERIOR DESIGN CONDITIONS:

THE INTERIOR DESIGN TEMPERATURES FOR HEATING AND COOLING AS DEPICTED IN THE PROJECT DESIGN CONDITIONS SCHEDULE IN THE MECHANICAL CONTROL DRAWINGS SHALL BE THE MAXIMUM

AND MINIMUM VALUES FOR THE ASSOCIATED TEMPERATURE CONTROL ZONES.

BUILDING ENVELOPE REQUIREMENTS (TABLE 5.5-4):

ROOFS: REQUIRED: DESIGNED:

INSULATION ABOVE DECK R-30 c.i. R-30 METAL BUILDINGS: R-19 + R-11 Ls or R-25 + R-8 Ls N/A

ATTIC AND OTHER: R-49 N/A

WALLS, ABOVE GRADE

MASS: R-9.5 c.i. N/A METAL BUILDING: R-0 + R-15.8 c.i. N/A STEEL-FRAMED: R-13 + R-7.5 c.i. R24.52 WOOD-FRAMED AND OTHER: R-13 + R-3.8 c.i. or R-20 N/A

WALL, BELOW GRADE

BELOW-GRADE WALL: R-7.5 c.i. N/A

FLOORS

MASS: R-14.6 c.i. N/A

STEEL-FRAMED: R-30 N/A

WOOD-FRAMED AND OTHER: R-30 N/A

SLAB-ON-GRADE FLOORS

UNHEATED SLABS: R-15 FOR 24 in. R-15 HEATED SLABS: R-20 for 24 in. N/A

OPAQUE DOORS

SWINGING: U-0.370 U-X.XX

NON-SWINGING: U-0.310 U-X.XX

FENESTRATION (TABLE 5.5-4)

VERTICAL FENESTRATION, U-FACTOR

NON-METAL FRAMING (ALL): U-0.31 U-X.XX

METAL FRAMING, FIXED: U-0.36 U-X.XX

METAL FRAMING, OPERABLE: U-0.45 U-X.XX

METAL FRAMING, ENTRANCE DOOR: U-0.63 U-X.XX

SKYLIGHT, 0% TO 3% OF ROOF, U-FACTOR

ALL TYPES: U-0.50 U-X.XX

DEFINITIONS

c.i = CONTINUOUS INSULATION Ls = LINEAR SYSTEM

NR = NO (INSULATION) REQUIREMENT

ENERGY REQUIREMENTS

1. DRAWINGS ARE PART OF A COMPLETE DOCUMENTS SET. CONTRACTOR SHALL

CONFIRM ALL ITEMS REQUIRED BASED UPON THE OVERALL DESIGN INTENT OF THE

ENTIRE DOCUMENT SET.

2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, PRIOR TO BEGINNING ANY

WORK, TO CONFIRM THE ACCURACY OF THE DRAWINGS AND REPORT ANY

DISCREPANCIES TO THE ARCHITECT. DO NOT SCALE THE DRAWINGS. FIELD VERIFY

ALL DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.

3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS PROJECT SHALL BE KEPT

CLEAN AND FREE OF OBSTRUCTIONS AT ALL TIMES.

4. ERECT BARRICADES AND WARNING SIGNS TO DIVERT AND WARN PASSERS-BY OF THE

CONSTRUCTION WORK. PROVIDE DUST PROOFING ENCLOSURES TO SEPARATE WORK

AREAS FROM THE EXISTING FACILITIES.

5. ALL TRASH AND DEBRIS TO BE REMOVED ON A DAILY BASIS.

6. PROVIDE PROTECTION FOR ALL EXISTING SURFACES AND CONDITIONS TO REMAIN IN

PLACE DURING THE SCOPE OF WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND

REPAIR ANY DAMAGE TO ADJACENT FINISHES TO MATCH EXISTING.

7. ANY DAMAGE CAUSED TO THE BUILDING OR OWNER EQUIPMENT SHALL BE REPAIRED

OR REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL COST TO THE

OWNER.

8. COVER ALL RETURN AIR GRILLES WITHIN THE AREA OF CONSTRUCTION TO PREVENT

PARTICULATE MATERIAL FROM EXHAUSTING INTO SURROUNDING SPACES.

9. APPROPRIATE LIGHT FIXTURES SHALL BE TEMPORARILY SUSPENDED TO PROVIDE

ADEQUATE LIGHTING LEVELS FOR CONSTRUCTION.

10. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO COORDINATE WITH OTHER

DISCIPLINES TO INSTALL COMPLETE AND OPERATIONAL SYSTEMS. DRAWINGS, AS A

WHOLE, REPRESENT A COMPLETE SET AND DEPICT REQUIREMENTS FOR COMPLETE

AND OPERATIONAL SYSTEMS. INDIVIDUAL DRAWINGS MAY NOT DEPICT COMPLETE AND

ACCURATE INFORMATION TO COORDINATE COMPLETE AND OPERATIONAL SYSTEMS,

BUT DO SO AS AN ENTIRE DOCUMENT TO BE REFERENCED WITH OTHER INDIVIDUAL

DRAWINGS. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO REFERENCE

OTHER SHEETS AND SPECIFICATIONS AS AN ENTIRE SET OF CONSTRUCTION

DOCUMENTS THAT REFLECT WORK REQUIRED TO ACHIEVE A COMPLETE AND

OPERATIONAL GOAL. LACK OF COORDINATION AND REVIEW OF DRAWINGS AND

SPECIFICATIONS AS AN ENTIRE DOCUMENT TO INSTALL COMPLETE AND OPERATIONAL

SYSTEMS, BEING OBVIOUS AND TYPICAL INDUSTRY STANDARD, IDENTIFIED IN THE

DRAWINGS AND SPECIFICATIONS, SHALL NOT BE IN ANY WAY AN ADDITIONAL COST TO

THE GOVERNMENT.

11. CONTRACTOR SHALL SUBMIT A REQUEST, IN WRITING, TO INTERRUPT ANY SUCH

SERVICES TO COR (CONTRACTING OFFICER’S REPRESENTATIVE) 48 HOURS IN

ADVANCE OF PROPOSED INTERRUPTION. REQUEST SHALL STATE REASON, DATE,

EXACT TIME OF, AND APPROXIMATE DURATION OF SUCH INTERRUPTION. MAJOR

INTERRUPTIONS OF ANY SYSTEM MUST BE REQUESTED, IN WRITING, AT LEAST 60

CALENDAR DAYS PRIOR TO THE DESIRED TIME AND SHALL BE PERFORMED AS

DIRECTED BY THE COR. MAJOR INTERRUPTIONS SHALL BE COORDINATED WITH OTHER

MAJOR INTERRUPTIONS AND MAY NOT BE SCHEDULED FOR ONE DISCIPLINE MORE

THAN TWICE THROUGHOUT THE OVERALL CONSTRUCTION SCHEDULE UNLESS

REQUESTED IN WRITING AND APPROVED BY THE COR. CONTRACTOR WILL BE ADVISED,

IN WRITING, OF APPROVAL OF REQUEST, OR OF WHICH OTHER DATE AND/OR TIME

SUCH INTERRUPTION WILL CAUSE THE LEAST INCONVENIENCE TO OPERATIONS OF

THE MEDICAL CENTER. INTERRUPTION TIME APPROVED BY THE MEDICAL CENTER MAY

OCCUR AT TIMES OTHER THAN CONTRACTOR'S NORMAL WORKING HOURS. SCHEDULE

INTERRUPTION MAY BE ON WEEKENDS OR LATE HOURS AND MAY NOT BE AN

ADDITIONAL COST TO THE GOVERNMENT. COORDINATE ALL INTERRUPTIONS THAT MAY

AFFECT THE NORMAL OPERATION OF THE FACILITY WITH THE COR WHEN SUBMITTING

THE CONSTRUCTION SCHEDULE OR UPDATES TO THE CONSTRUCTION SCHEDULE.

12. NO ASBESTOS CONTAINING MATERIALS ARE TO BE USED ON THIS PROJECT. SPUR

DESIGN, THE A/E OF RECORD, CAN CERTIFY THAT NO ASBESTOS CONTAINING

BUILDING MATERIALS (ACBM) OR LEAD BASED PAINT (LBP) PRODUCTS WERE

DESIGNED/SPECIFIED AS BUILDING MATERIAL IN ANY OF THE CONSTRUCTION

DOCUMENTS.

13. REFER TO THE DESIGN BINDER FOR THE ICRA INFORMATION DOCUMENTATION

GENERAL NOTES

FIBERGLASS BATT

INSULATION

RIGID INSULATION

CONCRETE / PRECAST

CONCRETE

EARTH / SOIL

SAND, EIFS FINISH, OR

PLASTER FINISH

GYPSUM BOARD FINISH

BRICK

CONCRETE MASONRY

UNIT

STONE / CAST STONE

GYPSUM BOARD SECTION

EXTERIOR SHEATHING

BOARD SECTION

PLYWOOD SECTION

ABBREVIATIONS

A

ACB ACOUSTIC CEILING BAFFLE

ACP ACOUSTIC CEILING PANEL

ACST ACOUSTIC

ADA AMERICANS WITH DISABILITIES ACT

ACT ACOUSTICAL CEILING TILE

ADDL ADDITIONAL

ADDN ADDITION

ADJ ADJACENT, ADJOINING, OR

ADJUSTABLE

ADMIN ADMINISTRATION

AE ARCHITECT/ENGINEER

AF ACCESS FLOORING

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AHJ AUTHORITY HAVING JURISDICTION

AIA AMERICAN INSTITUTE OF

ARCHITECTS

ALT ALTERNATE

ALT NO ALTERNATE NUMBER

ALUM ALUMINIUM (TRIM)

AMT AMOUNT

APPROX APPROXIMATE

ARCH ARCHITECT

ASC ABOVE SUSPENDED CEILING

AT ACOUSTIC CEILING TILE

AVG AVERAGE

B

BD BOARD

BLDG BUILDING

BLKG BLOCKING

BLT IN BUILT-IN

BOS BOTTOM OF STEEL

BOT BOTTOM

BRKT BRACKET

BTWN BETWEEN

C

CAB CABINET

CAV CAVITY

CBB CONCRETE BACKER BOARD

CD CONSTRUCTION DOCUMENTS

CFM CUBIC FEET PER MINUTE

CFS CUBIC FEET PER SECOND

CG CORNER GUARD

CH BD CHALK BOARD

CIP CAST-IN-PLACE

CJ CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLG HT CEILING HEIGHT

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CO CONTRACTING OFFICER

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONT CONTINUOUS

COORD COORDINATE

COR CONTRACTING OFFICER'S

REPRESENTATIVE

CP CONTRACTOR PROVIDED

CP/CI CONTRACTOR PROVIDED /

CONTRACTOR INSTALLED

CPT CAROET/CARPET TILE

CS CONCRETE SEALED

CSWK CASEWORK

CT CERAMIC TILE

CTB CERAMIC TILE BASE

CTR CENTER

CU FT CUBIC FEET

D

DBL DOUBLE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DIA DIAMETER

DIR DIRECTION

DIST DISTANCE

DOC DOCUMENT

DR DOOR

DS DOWNSPOUT

DWG DRAWING

DWP DIMENSIONAL WALL PANEL

E

EA EACH

EJ EXPANSION JOINT

EL ELEVATION

ELEV ELEVATOR

ENTR ENTRANCE

EPY EPXOY FLOORING

EQ EQUAL

ETR EXISTING TO REMAIN

EX EXISTING

EXP EXPOSED

EXT EXTERIOR

F

FAB FABRIC

FED FEDERAL

FF FINISH FACE

FF EL FINISH FLOOR ELEVATION

FIN FINISH

FIN BS FINISH BOTH SIDES

FIN FLR FINISH FLOOR

FIN GR FINISH GRADE

FIXT FIXTURE

FLDG FOLDING

FLEX FLEXIBLE

FLG FLOORING

FLMT FLUSH MOUNT

FLR FLOOR

FOC FACE OF CONCRETE

FOM FACE OF MASONRY

FP FIRE PROTECTION

FR FIRE RESISTANT

FT FEET

FTG FOOTING

FV FIELD VERIFY

G

GDR GUARDRAIL

GL GLASS/GLAZING

GRAN GRANITE

GR FL GROUND FLOOR

GT GROUT

GSM GALVANIZED SHEET METAL

GYP BD GYPSUM BOARD

H

HDW HARDWARE

HEPA HIGH EFFICIENCY

PARTICULATE AIR (FILTER)

HMD HOLLOW METAL DOOR PAINT

HMDF HOLLOW METAL DOOR FRAME

PAINT

HMWF HOLLOW METAL WINDOW FRAME

PAINT

HORIZ HORIZONTAL

HR HANDRAIL

HT HEIGHT

HW HARDWARE

I

IBC INTERNATIONAL BUILDING CODE

INSUL INSULATION

INT INTERIOR

ILO IN LIEU OF

J

J-BOX JUNCTION BOX

L

LAV LAVATORY

LBS POUND

LDG LANDING

LF LINEAR FEET (FOOT)

LIN LINEAR

LN LINOLEUM

LOC LOCATION

LT LIGHT

LVR LOUVER

LVT LUXURY VINYL TILE

M

MAT CARPET MAT / WALK-OFF MAT

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MEMB MEMBRANE

MFR MANUFACTURER

MID MIDDLE

MIL STD MILITARY STANDARD

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

MOD MODIFY

MTG MOUNTING

MTL METAL

MVBL MOVABLE

N

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

O

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER

OPNG OPENING

OPP OPPOSITE

OPR OPERABLE

ORD OVERFLOW ROOF DRAIN

ORIG ORIGINAL

OTS OPEN TO STRUCTURE

P

P PAINT

PA PUBLIC ADDRESS

PBD PARTICLE BOARD

PCF POUNDS PER CUBIC FOOT

PCT PERCENT

PERF PERFORATED

PERIM PERIMETER

PERP PERPENDICULAR

PL PROPERTY LINE

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PNL PANEL

PR PAIR

PRB PROFILE BASE

PRKG PARKING

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PORCELAIN TILE

PWR POWER

Q

QA QUALITY ASSURANCE

QC QUALITY CONTROL

QTY QUANTITY

R

RAF RESILIENT ATHLETIC FLOORING

RB RUBBER BASE/RESILIENT BASE

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REC RECESSED

REF REFERENCE

REM REMOVABLE

REP REPAIR

REPL REPLACE

REQ REQUIRE

REQD REQUIRED

RES RESINOUS FLOORING

RES-W RESINOUS / EPOXY WALL / CEILING

RF RUBBER FLOORING

RFG ROOFING

RM ROOM

RO ROUGH OPENING

RP RESIN PANEL

RSF RESILIENT SHEET FLOORING

RV ROOF VENT

RWC RIGID VINYL WALLCOVERING

S

SC SPECIALTY COATING

SD STATIC DISSIPATIVE FLOORING/TILE

SCHED SCHEDULE

SECT SECTION

SF SQUARE FOOT (FEET)

SGL SINGLE

SIM SIMILAR

SJ SCORED JOINT

SLNT SEALANT

SM SHEET METAL

SPEC SPECIFICATION

SQ SQUARE

SQ IN SQUARE INCH

SQ YD SQUARE YARD

SS SOLID SURFACE

ST STONE

STD STANDARD

STOR STORAGE

SV SHEET VINYL (ROLLED OR TILE)

T

TEL TELEPHONE

TEMP TEMPORARY

TER TERRAZZO

TOF TOP OF FOOTING/ FOUNDATION

TOM TOP OF MASONRY

TOS TOP OF SLAB/ STEEL

U

UNO UNLESS NOTED OTHERWISE

UTIL UTILITY

V

VAR VARIES

VC VA PROVIDED / CONTRACTOR

INSTALLED

VCT VINYL COMPOSITION TILE

VFAT VINYL FACED ACOUSTICAL TILE

VP VENEERED PLASTER

VT VINYL TILE

VV VA PROVIDED / VA INSTALLED

VWC VINYL WALLCOVERING

VWF VINYL WALL FABRIC

W

W/ WITH

W/O WITHOUT

W/C WATER CLOSET

WC WHEELCHAIR

WD WOOD

WFAB WALL FABRIC

WPM WATERPROOF MEMBRANE

WSF WELDED SHEET FLOOR

X

X BRACE CROSS BRACE

4' -0

M

A X

4' -0

M

A X

2' -1

0" M

A X

2' -3

M

IN

1'-6" MIN

1. GENERAL CONTRACTOR TO PROVIDE METAL SUPPORT

BLOCKING FOR ALL WALL MOUNTED ACCESSORIES,

FIXTURES, AND EQUIPMENT.

2. PROVIDE ADA SUPPORT BRACKETS PLACED AT ALL OPEN

COUNTERTOPS @ 36"-48" MAX ON CENTER.

3. SPECIFIED MAXIMUMS ARE MEASURED FROM AFTER

FINISHED FLOOR TO THE OPERABLE PART OF THE FIXTURE.

4. FIXTURES SHOWN ARE REPRESENTATIONAL ONLY. NOT ALL

FIXTURES MAY BE USED. REFER TO SPECIFICATIONS FOR

FIXTURE TYPES USED IN THIS PROJECT.

5. FIXTURES MAY OVERLAP WAINSCOT. WHERE APPLICABLE,

BACKING TO BE PROVIDED AS SHIM FOR FLUSH

APPLICATION. SHIM TO MATCH SCHEDULED WALL FINISH.

6" MAX

9" M

IN

SHOWER

TOILET ROOM

TURNING RADIUS

DRINKING

FOUNTAIN

PAPER TOWEL

DISPENSER

SANITARY

NAPKIN

DISPENSER

4' -0

"M A

X

WASTE

RECEPTACLE

LAVATORY

WITH MIRROR

ON CENTER

WALL

4' -0

M

A X

SOAP

DISPENSER

2' -1

0" M

A X

T O

B .O

. R E

F

LE

C T

IV

E

S U

R F

A C

E

3' -4

"M A

X

17 MIN

2' -3

M

IN

3' -0

M

A X

1'-6" MIN

WALL

2' -9

3' -0

M A

X

4' -0

2'-0" MIN

8" MIN

WALL

LAVATORY

WITH APRON

1' -5

M

A X

1'-6" MIN

URINAL

WALL

1'-5" - 1'-7" (AMBULATORY)

1'-4" - 1'-6" (WHEELCHAIR)

CLEAR FLOOR

5'-6"

CLEAR FLOOR

6'-0"

3'-0" MIN

2' -9

3' -0

1'-0" MIN

3'-6" MIN 1'-0"MAX

4'-6" MIN

1' -5

'-7

1' -6

M

IN

A N

S I I

C C

A

7.

1)

1' -3

M

IN

A D

A /A

B A

2' -9

'-0

WALL

WALL

4' -0

M

A X

WALL HOOK

7' -0

CLOCK

WALL

FINISHED FLOOR

FIRE EXTINGUISHER

CABINET

WEIGHT > 40LBS

FIRE EXTINGUISHER

CABINET

WEIGHT < 40LBS

4' -0

"M A

X

4' -0

M

A X

TOILET SEAT

COVER

DISPENSER

BABY

CHANGING

STATION

CLEAR FLOOR SPACE

@ WATER CLOSET

5'-6"

2'-6"

4' -0

2'-6"

4' -0

HANDRAILS AND

BUMPERGUARDS

FIXTURE MOUNTING HEIGHTS AND CLEARANCES

18" MIN

M

IN

FRONT APPROACH,

PULL SIDE

36" MIN

M

IN

HINGE APPROACH,

PULL SIDE

HINGE APPROACH,

PULL SIDE

*12" MIN48

M

IN

FRONT APPROACH,

PUSH SIDE

M

IN

HINGE APPROACH,

PUSH SIDE

22" MIN 24" MIN

*4 8"

M

IN

LATCH APPROACH,

PULL SIDE

24" MIN*4

2"

M

IN

LATCH APPROACH,

PUSH SIDE

*IF BOTH CLOSER

AND LATCH ARE

PROVIDED

*54" MIN IF CLOSER

IS PROVIDED

*48" IF CLOSER IS

PROVIDED

FRONT APPROACH,

PUSH SIDE

M

IN

42" MIN

DOOR AND FIXTURE CLEARANCES

N

AREA NAME

150 SF

A101

A101

SIM

A

00.0

A101

1 1

A101

LEVEL NAME

00'-00"

00'-00" 4B

3A

ROOM NAME

150 SF

000A

ROOM NAME

000A

/1 A101

X0000

6"

3' -0

M

A X

ROOM TAG

AREA TAG

SPECIALTY EQUIPMENT TAG

DOOR TAG

KEYED NOTE TAG

WALL TAG

WINDOW TAG

A101

SIM

A101

SIM

REFERENCE SYMBOLS IDENTIFICATION TAGS

NOTE: NOT ALL ABBREVIATIONS OR SYMBOLS WILL BE UTILIZED FOR THIS PROJECT.

GRID HEAD AND

LINE

LEVEL INDICATOR

MATCH LINE AND

VIEW REFERENCE

NORTH ARROW W/

PROJECT NORTH

SPOT ELEVATION

DETAIL

SECTION

**48" MIN IF BOTH CLOSER

AND LATCH PROVIDED

WALL

SECTION

BUILDING

SECTION

DETAIL

ELEVATION

INTERIOR

ELEVATION

BUILDING

ELEVATION

1 1

6'- 0"

5'- 6"

BARIATRIC TOILET ROOM

TURNING RADIUS

CLEAR FLOOR SPACE

@ ADA LAVATORY

CLEAR FLOOR SPACE @ ADA

DRINKING FOUNTAIN

4"

6"

3"

6"

1' -6

6" MAX

7" - 9" 11" MIN

17" - 25"

M

IN

6' -0

(ANSI ICC A117.1)

39"- 41"

(A N

S I I

C C

A

7.

1)

M

IN

(A N

S I I

C C

A

7.

1)

1"

3' -6

M

A X

5' -0

M

A X

PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT AND USE OF VOLUNTARY STANDARDS, OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY STANDARDS, BOTH DOMESTIC AND INTERNATIONAL, WHENEVER FEASIBLE, AND TO PARTICIPATE IN

VOLUNTARY STANDARD BODIES.

GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS

SPECIFY OTHER CODES AND STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:

• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL

INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).

• 2021 INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES BELOW)

• 2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC) (IF APPLICABLE)

• 2021 NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)

• NATIONAL FIRE CODES (NFC) PUBLISHED BY THE NATIONAL FIRE PROTECTION ASSIATION (NFPA)

• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS

• 2020 VA SEISMIC DESIGN REQUIREMENTS, H-18-8

• 2021 VA PHYSICAL SECURITY & RESILIENCY DESIGN MANUAL

• 2020 NATIONAL ELECTRICAL CODE (NEC), NFPA 70

• 2021 INTERNATIONAL PLUMBING CODE (IPC)

• 2016 SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.

• 2015 ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS INCLUDING VA SUPPLEMENT, VA BARRIER FREE DESIGN STANDARD (PG-18-13)

• 2017 ANSI ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES

• 2019 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318-19)

• 2017 STEEL CONSTRUCTION MANUAL (15TH EDITION), AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)

• ENERGY POLICY ACT OF 2005 (EPACT)

• 2007 DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND

NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434 AND 435.

• 2006 FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)

• 2018 EXECUTIVE ORDER 13834: EFFICIENT FEDERAL OPERATIONS

• 2021 THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 010000 OF THE VA MASTER CONSTRUCTION

SPECIFICATION.

• 2019 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1

• 2019 SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15

LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION FEES.

NOTES:

1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT

NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN.

DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES

EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).

2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.

STANDARD ROLL-IN TYPE

SHOWER COMPARTMENT

SIZE AND CLEARANCE

NOTE: INSIDE FINISHED

DIMENSIONS MEASURED

AT THE CENTER POINTS

OF OPPOSING SIDES

BACK

WALLSIDE

WALL

SIDE

WALL

60 MIN

M

IN

M

IN

PROJECT SUMMARY

THE SCOPE OF THE PROEJECT ENTAILS BUILDING AN EXPANSION ADDITION TO THE EXISTING BUILDING 60 AS WELL AS RENOVATING PORTIONS OF THE CURRENT BUILDING. TWO NEW ENTRY VESTIBULES WILL BE CONSTRUCTED INTO THE EXISTING BUIILDING. EXTERIOR MODIFICATIONS INCLUDE LANDSCAPING, HARDSCAPE AREAS, AND NEW INFASTRUCTURE FOR THE ADDITION.

MATERIALS LEGEND

7' -0 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. A-930 EXP. 12/31/2023

ENGR REG. NO. E-2586 EXP. 12/31/2023

STRUCTURAL/CIVIL

ENGINEER

H2B

1225 N. LOOP W #800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH

ENGINEER

SPUR DESIGN

11020 KING STREET, STE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

LANDSCAPE ARCHITECT

CLS & ASSOCIATES

825 N. BROADWAY AVE, STE 315

OKLAHOMA, OK 73102

(405) 525-2220

HEALTHCARE/MED

EQUIPMENT PLANNER

INNOVA GROUP

3196 N. SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT SECURITY

CONSULTANTS,

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

FOOD & BEVERAGE

PLANNER

STURM CONSULTING

5838 S. HUDSON PLACE

TULSA, OK 74135

(918) 260-0667

ENVIRONMENTAL

ENGINEER

RIVERFRONT ENVIRONMENTAL

1139 OLIVE STREET, STE 300

ST. LOUIS, MO 63101

(314) 436-9492

SPUR #: 2015

/5

/2

:3

:4

A

M

GENERAL INFORMATION

NR 002 OF 221DLK

BID DOCUMENTS

ADDITION AND RENOVATION

OF CLC

09/06/2023

589-703

ROBERT J. DOLE VA MEDICAL CENTER

5500 EAST KELLOGG, BLDG. 60

WICHITA, KS 67218

GI001

FD

FD

FD

FD

FD

FD

FD

E12E11E10E9AE8A

ED

EE

EF

EG

E13E7

EF1

EH

P

EJ

EK

E6 E8 E9

EA

EB

E1 E2 E3

EC

E4 E5

PHASE 1

M

1B153

1B152

1B147A 1B147

1B145

1B144

1B151

1B149

1B120A

1B120

101B

1B100B

1B100A

1B100

1B101 1B103

1B103A

1B105 1B107 1B109 1B111 1B113 1B115

1B113A

1B109A1B105A

1B103B

1B106 1B108 1B110 1B112 1B114 1B116

1B114A1B110A1B108A

1B104 1B117

1B118

1B119

1B121

1B122

1B121A

1B143 1B123

1B150

1B150

108C

114A 108B

103A

109A

113A

108A

110E

110F

110D 110C

110B 110A

1B133

1B133A

1B134

1B135A

1B1351B1361B1371B138

1B137A 1B136A

1B130

1B131

1B131A

1B132

1B125

1B127

1B141

1B124

1B142

1B140

1B140A

E12E11E10E9AE8A

ED

EE

EF

EG

E13

EF1

EH

P

EJ

EK

E6 E8 E9

EA

EB

E1 E2 E3

EC

E4 E5

F

D

A

876543

K

I

H

J

5.521

C

96.5

B

E

2.5 3.5

N

G

C.3PHASE 2VESTIBULE

006A

IT ROOM

116ELECTRICAL

FIRE RISER RM

115A

BATHING RM

117 TOILET

117A

HOUSE OFC

KITCHEN

DINING

133B

LIVING ROOM

133ART OFC

MED

HOUSE STOR.

HOUSE LNDRY

ART ROOM

MP STOR

132A

MULTIPURPOSE/

ACTIVITY ROOM

132TLT

CONF. / PRIVATE

DINING

EXTERIOR

COURTYARD

EXTERIOR

COURTYARD

RESIDENT

RESIDENT

STAFF LOUNGE

TLT

BATH

151A

BATH

152A

CORRIDOR

CORRIDOR

VESTIBULE

008A

RESIDENT

146BATH

146A

RESIDENT

DEN

BATH

145A

EQ. STOR

RESIDENT

RESIDENT

BATH

138A

BATH

141A

BATH

137A

RESIDENT

RESIDENT

BATH

143A

RESIDENT

BATH

142A

BATH

140A

RESIDENT

RESIDENT

BATH

139A

BATH

136A

RESIDENT

RESIDENT

BATH

135A

BATH

134A

RESIDENT

RESIDENT

RESIDENT

RESIDENT,

BARIATRIC

BATH

121A

BATH

122A

HAC

SOILED UTL

CLEAN SUPPLY

120 PANTRY

133C

108C

114A 108B

103A

109A

113A

108A

110E

110F

110D 110C

110B 110A

0-LOBBY-A

1B153

1B152

1B147A 1B147

1B145

1B133

1B133A

1B134

1B135A

1B1351B1361B1371B138

1B137A 1B136A

1B130

1B131

1B131A

1B132

1B125

1B127

1B141

1B124

1B142

1B140

1B144

0-ENTRY

1B151

1B149

1B120A

1B120

0-WAITING

RECEPT.

101B

1B100B

1B105 1B107 1B109 1B111 1B113 1B115

1B113A

TLT

1B109ATLT

1B105A

1B103B

1B106 1B108 1B110 1B112 1B114 1B116

1B114A1B110A1B108A

1B104 1B117

1B118

1B119

1B121

1B122

1B121A

1B143 1B123

1B150

1B150

1B140A

101A

PHASING PLAN LEGEND

PHASE 1

PHASE 2

NOT IN SCOPE

PHASE 3

PHASE 4

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. A-930 EXP. 12/31/2023

ENGR REG. NO. E-2586 EXP. 12/31/2023

STRUCTURAL/CIVIL

ENGINEER

H2B

1225 N. LOOP W #800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH

ENGINEER

SPUR DESIGN

11020 KING STREET, STE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

LANDSCAPE ARCHITECT

CLS & ASSOCIATES

825 N. BROADWAY AVE, STE 315

OKLAHOMA, OK 73102

(405) 525-2220

HEALTHCARE/MED

EQUIPMENT PLANNER

INNOVA GROUP

3196 N. SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT SECURITY

CONSULTANTS,

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

FOOD & BEVERAGE

PLANNER

STURM CONSULTING

5838 S. HUDSON PLACE

TULSA, OK 74135

(918) 260-0667

ENVIRONMENTAL

ENGINEER

RIVERFRONT ENVIRONMENTAL

1139 OLIVE STREET, STE 300

ST. LOUIS, MO 63101

(314) 436-9492

SPUR #: 2015

/5

/2

:3

:0

A

M

PHASING PLANS

NR 003 OF 221DLK

BID DOCUMENTS

ADDITION AND RENOVATION

OF CLC

09/06/2023

589-703

ROBERT J. DOLE VA MEDICAL CENTER

5500 EAST KELLOGG, BLDG. 60

WICHITA, KS 67218

GI011

N

1/16" = 1'-0"

PHASE 1 - DEMO1

N

1/16" = 1'-0"

PHASE 2 - NEW CONSTRUCTION - AREA A2

PHASE DESCRIPTIONS & OVERVIEW PHASE 1 - DEMOLITION OF SITE WORK IN PREPARATION FOR THE NEW ADDITION

1. A CONSTRUCTION STAGING AREA WILL BE SET UP ADJACENT TO THE SITE ACROSS THE ROAD, PLAN EAST OF THE EXISTING BUILDING #60 FOOTPRINT. THERE IS AN EXISTING GRAVEL PARKING AREA THAT CAN BE USED FOR CONSTRUCTION STAGING.

2. THIS WILL INCLUDE THE DEMOLITION OF THE EXISING NORTH GARDEN AREA FOR THE CONSTRUCTION OF THE NEW ADDITION. ALL TREES, UTILITIES, STRUCTUES (WHICH INLCUDES THE EXISTING GAZEBO), AND SIDEWALKS ARE TO BE REMOVED.

3. THE EXISTING SMOKING PORCH ADJACENT TO THE EXISTING CAFETERIA ARE IN THE PT/OT AREA WILL BE DEMOLISHED. THE EXISTING BRICK, COLUMNS, WINDOWS, ROOF, AND STRUCTURE WILL BE REMOVED. THE CONTRACTOR WILL NEED TO PAY CLOSE ATTENTION IN KEEPING THE EXISTING INTERIOR WALLS AROUND THE SMOKING PORCH INTACT DURING THIS DEMOLITION, SINCE THESE WALLS AND ASSOCIATED ELEMENTS WILL BE SAVED. CONTRACTOR TO PREP ANY EXTERIOR SURFACES THAT ARE EXPOSED IN THEIS AREA AFTER

DEMOLITION TO BE WEATHER RESISTANT.

4. SOME ADDITIONAL DEMOLITION WILL NEED TO TAKE PLACE IN SOME OF THE EXISTING EAST WING SO AS TO REMOVE EXISTING UTILITIES AND BRING IN NEW UTILITIES. THE AREAS AFFECTED WILL NEED ICRA BARRIERS AND EXTERIOR BARRIERS TO PROTECT THE ADJACENT AREAS THAT NEED TO REMAIN FUNCTIONAL DURING CONSTRUCTION AND TO PROTECT STAFF AND THE PATIENTS.

PHASE 2 - NEW CONSTRUCTION OF CLC ADDITION.

1. ONCE THE DEMOLITION OF THE EXTERIOR AREA TO THE NORTH OF THE EXISTING EAST

WING AND SMOKING PORCH HAS BEEN COMPLETED THEN NEW CONSTRUCTION CAN

COMMENCE. NEW UTILITIES WILL BE INSTALLED AND NEW STRUCTURAL FOOTING,

GRADE BEAMS AND SLABS WILL BE PLACED. NEW STEEL COLUMNS AND BEAMS WILL

BE INSTALLED PRIOR TO ROOFING AND EXTERIOR ENVELOPE INSTALLATION.

2. ONCE THE BUILDING IS ENCLOSED THE INTERIOR STUD WALLS CAN PUT UP AND DOORS

AND FRAMES CAN BE INSTALLED. MEP CAN START TO RUN DUCTWORK, PIPING,

CABLING, AND ANY OTHER ITEMS THROUGHTOUT THE NEW ADDITION.

3. ALL FINISHES TO BE INSTALLED ONCE ALL THE INTERIOR WALLS ARE UP AND IN PLACE.

CASEWORK INSTALLATION CAN OCCUR ALONG WITH FINISHES.

4. ONCE CASEWORK AND FINISHES HAVE BEEN INSTALLED, THEN ALL MEDICAL

EQUIPEMENT AND FURNISHINGS CAN BE INSTALLED.

PHASE 3 - DEMOLITION OF EXISTING CLC ROOMS AND SPACES TO BE RENOVATED.

1. ONCE THE NEW ADDITION HAS BEEN FINISHED AND ACCPETED BY THE VA FOR USE, THEN THE EAST

WING AND PORTION OF THE SOUTH WING OF THE EXISTING BUILDING #60 CAN START TO BE

DEMOLISHED. THIS INCLUDES BUT IS NOT LIMITED TO: FLOOR SLABS AS SPECIFIED FOR NEW UTILITIES, INTERIOR STUD WALLS, DOORS AND FRAMES, CEILINGS, AND MEP ITEMS. THE CONTRACTOR WILL BE

RESPONSIBLE TO PROTECT ALL ADJACENT AREAS THAT ARE TO REMAIN IN OPERATION DURING

DEMOLITION SO AS TO PROTECT THE STAFF AND PATIENTS. THE CONTRACTOR WILL COORDINATE ALL

ICRA BARRIERS AS NEEDED.

2. IN ADDITION TO THE EAST AND SOUTH WING DEMOLITION, THE EXISTING ENTRY LOBBY AREA WILL NEED TO BE UPDATED. DEMOLITION OF THIS AREA INCLUDES THE FOLLOWING ITEMS, BUT IS NOT LIMITED TO:

STUD WALLS, DOORS AND FRAMES, CEILINGS, AND MEP ITEMS AS NEEDED TO BE REMOVED. DURING THIS TIME, A NEW EXTERIOR VESTIBULE WILL BE CONSTRUCTED WHICH WILL ENTAIL THE REMOVAL OF

SOME OF THE EXTERIOR FINISHES. THE CONTRACTOR WILL BE REPSONSIBLE TO PROTECT ALL

ADJACENT AREAS THAT ARE TO REMAIN IN OPERATION DURING DEMOLITION TO PROECT THE STAFF

AND PATIENTS. THE CONTRACTOR WILL COORDINATE ALL ICRA BARRIERS AS NEEDED.

PHASE 4 - RENOVATION OF THE EXISTING CLC

1. ONCE THE DEMOLITION OF THE EXTERIOR AREA TO THE NORTH OF THE EXISTING EAST WING AND SMOKING PORCH HAS BEEN COMPLETED THEN NEW CONSTRUCTION CAN COMMENCE. NEW CONSTRUCTION WIL INCLUDING THE FOLLOWING, BUT NOT LIMITED TO: NEW STUD WALLS, DOORS AND FRAMES, CEILINGS, AND MEP RELATED PIPING, DUCTWORK, AND CABLING. THE CONTRACTOR WILL BE RESPONSIBLE FOR PROTECTION OF ALL ADJACENT AREAS THAT ARE TO REMAIN IN OPERATION DURING NEW CONSTRUCTION TO PROJECT THE STAFF AND PATIENTS. THE CONTRACTOR WILL COORDINATE ALL ICRA BARRIERS AS NEEDED.

2. ONCE THE WALLS AND ASSOCIATED MEP ITEMS HAVE BEEN INSTALLED THEN WALL, FLOOR AND CIELING FINISHES CAN BE INSTALLED. MILLWORK INSTALLATION CAN

OCCUR ALONG WITH FINISHES.

3. ONCE THE MILLWORK AND FINISHES HAVE BEEN INSTALLED, ALL MEDICAL EQUIPMENT AND FURNISHINGS CAN BE INSTALLED.

4. IN ADDITION TO THE EAST AND SOUTH WING NEW CONSTRUCTION, THE EXISTING ENTRY LOBBY AREA WILL NEED TO BE UPDATED WITH A NEW LAYOUT. NEW CONSTRUCTION OF THIS AREA WILL NEED TO BE DONE WHICH INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING ITEMS: STUD WALLS, DOORS AND FRAMES, CEILINGS, AND MEP ITEMS AS NEEDED TO BE INSTALLED. FURTHERMORE, DURING THIS TIME, A NEW EXTERIOR VESTIBULE WILL ENTAIL THE ADDITION OF NEW STRUCTURAL STEEL AND NEW EXTERIOR WALLS AND FINISHES. THE CONTRATOR WILL BE RESPONSIBLE FOR PROTECTION OF ALL ADJACENT AREAS THAT ARE TO REMAIN IN OPERATION DURING NEW CONSTRUCTION SO AS TO PROTECT THE STAFF AND THE PATIENTS. THE CONTRACTOR WILL COORDINATED ALL ICRA BARRIERS AS NEEDED.

PHASE 1 SCOPE

• DEMOLITION OF SITE WORK IN

PREPARATION FOR THE NEW ADDITION.

PHASE 2 SCOPE

• NEW CONSTRUCTION OF CLC ADDITION.

PHASE 3 SCOPE

• DEMOLITION OF THE EXISTING CLC ROOMS

AND SPACES TO BE RENOVATED.

• PREPARE SITE FOR EXTERIOR

IMPROVEMENTS

PHASE 4 SCOPE

• RENOVATION OF THE EXISTING CLC.

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

E12E11E10E9AE8A

ED

EE

EF

EG

E13E7

EF1

EH

P

EJ

EK

E6 E8 E9

EA

EB

E1 E2 E3

EC

E4 E5

F

D

A

876543

K

I

H

J

5.521

C

96.5

B

E

2.5 3.5

G

C.3

PHASE 3

M

TEMPORARY FENCE

WITH GATE FOR

TEMPORARY

BOILER AND AHU,

REFER TO

MECHANICAL.

108C

114A 108B

103A

109A

113A

108A

110E

110F

110D 110C

110B 110A

1B133

1B133A

1B134

1B135A

1B1351B1361B1371B138

1B137A 1B136A

1B130

1B131

1B131A

1B132

1B125

1B127

1B141

1B124

1B142

1B140

OFFICE

CPU

CHARGING

1B153

STOR

1B152

TLT

1B147A

TLC RM

1B147

TLC ROOM

1B145

TLC ROOM

1B144

LAUNDRY

1B151

MEDICATION

1B149

TLT

1B120A

RESTROOM

1B120

OPEN

OFFICE

OFFICE

101B

REC

1B100B

OXYGEN

TLC RM.

1B105

TLC RM.

1B107

TLC RM.

1B109

TLC RM.

1B111

TLC RM.

1B113

TLC RM.

1B115

TLT

1B113A

COPY

1B103B

TLC RM.

1B106

TLC RM.

1B108

TLC RM.

1B110

TLC RM.

1B112

TLC RM.

1B114

TLC RM.

1B116

TLC RM.

1B114A

TLC RM.

1B110A

TLC RM.

1B108A

SLD.

UTILITY

1B104

CLEAN

LINEN

1B117

BARBER

1B118

OFFICE

1B119

TLC RM.

1B121

BREAK RM.

1B122

TLT

1B121A

SOC. WKR.

1B143

PSY.

1B123

TLT

1B150

TLC KIT.

1B150

OFFICE

1B103A

CONF. /

PRIVATE

DINING

TLT

ART ROOM

MP

STOR

132A

MULTIPURPOSE/

ACTIVITY

ROOM

132A

RT OFC

MED

HOUSE

STOR.

HOUSE

LNDRY

TOILET

117A

BATHING

ROOM

IT

ROOM

ELEC

FIRE RISER

ROOM

VESTIBULE

006A

RESIDENT

BARIATRIC

RESIDENT

RESIDENT

RESIDENT

RESIDENT

RESIDENT

RESIDENT

RESIDENT

RESIDENT

RESIDENT

LIVING

ROOM

133A

KITCHEN

DINING

133B

SOILED

UTILITY

HOUSE OFC

PANTRY

133C

CLEAN

SUPPLY

BATH

135A

BATH

134A

BATH

122A

BATH

121ABATH

119A

BATH

136A

BATH

139A

BATH

140A

BATH

142A

BATH

143A

RESIDENT

RESIDENT

RESIDENT

BATH

138A

BATH

141A

BATH

137A

HAC

BATH

145A RESIDENT

RESIDENT

146BATH

146A

STOR

DEN

STAFF

LOUNGE

RESIDENT

RESIDENT

CORRIDOR

BATH

151A

TLT

VESTIBULE

008A

CORRIDOR

BATH

152A

1B140A

E12E11E10E9AE8A

ED

EE

EF

EG

E13E7

EF1

EH

P

EJ

EK

E6 E8 E9

EA

EB

E1 E2 E3

EC

E4 E5

F

D

A

876543

K

I

H

J

5.521

C

96.5

B

E

2.5 3.5

N

G

C.3

PHASE 4

1.8

108C

114A 108B

103A

109A

113A

108A

110E

110F

110D 110C

110B 110A

1B133

1B133A

1B134

1B135A

1B1351B1361B1371B138

1B137A 1B136A

1B130

1B131

1B131A

1B132

1B125

1B127

1B141

1B124

1B142

1B140

WAITING

CLEAN LINEN

SOILED UTL

GENERAL STOR

TEAM WORKRM

TEAM WORKRM

DEN

CORRIDOR

VESTIBULE

014A

RESIDENT - B2

BATH

175A

RESIDENT - B2

BATH

173A

MEDS

BATH

163A

BATH

161A

BATH

159A

BATH

158A

BATH

157A

BATH

156A

BATH

155A

RESIDENT - B1

RESIDENT - B1

153BATH

153A

CORRIDOR

BATH

160A

BATH

162A

BATH

164A

DINING

166B

LIVING ROOM

166A

RESIDENT DINING

N&FS KITCHEN/

SERVERY

131A

CORRIDOR

CORRIDOR

DIR OFC

MED DIR OFC

H. LAUNDRY

BATHING RM

TLT

184A

TLT

176A

EQUIP STOR

CLEAN SUPPLY

169NRS LDR OFC

SW OFC

178 HOUSE OFC

VESTIBULE

001A

PT/OT RECEP

100B

H. STOR

SSTV

131C

MOP

131B

HAC

154RESIDENT - B1

RESIDENT - B1

160RESIDENT - B1

RESIDENT - B2

RESIDENT - B2

161 RESIDENT - B2

RESIDENT - B2

158 RESIDENT - B2

RESIDENT - B2

CORRIDOR

OFFICE

1B103A

CONF. /

PRIVATE

DINING

TLT

ART ROOM

MP

STOR

132A

MULTIPURPOSE/

ACTIVITY

ROOM

132A

RT OFC

MED

HOUSE

STOR.

HOUSE

LNDRY

TOILET

117A

BATHING

ROOM

IT

ROOM

ELEC

FIRE RISER

ROOM

VESTIBULE

006A

RESIDENT

BARIATRIC

RESIDENT

RESIDENT

RESIDENT

RESIDENT

RESIDENT

RESIDENT

RESIDENT

RESIDENT

RESIDENT

LIVING

ROOM

133A

KITCHEN

DINING

133B

SOILED

UTILITY

HOUSE OFC

PANTRY

133C

CLEAN

SUPPLY

BATH

135A

BATH

134A

BATH

122A

BATH

121ABATH

119A

BATH

136A

BATH

139A

BATH

140A

BATH

142A

BATH

143A

RESIDENT

RESIDENT

RESIDENT

BATH

138A

BATH

141A

BATH

137A

HAC

BATH

145A RESIDENT

RESIDENT

146BATH

146A

STOR

DEN

STAFF

LOUNGE

RESIDENT

RESIDENT

CORRIDOR

BATH

151A

TLT

VESTIBULE

008A

CORRIDOR

BATH

152A

1B140A

1B1261B1281B129

PHASING PLAN LEGEND

PHASE 1

PHASE 2

NOT IN SCOPE

PHASE 3

PHASE 4

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. A-930 EXP. 12/31/2023

ENGR REG. NO. E-2586 EXP. 12/31/2023

STRUCTURAL/CIVIL

ENGINEER

H2B

1225 N. LOOP W #800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH

ENGINEER

SPUR DESIGN

11020 KING STREET, STE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

LANDSCAPE ARCHITECT

CLS & ASSOCIATES

825 N. BROADWAY AVE, STE 315

OKLAHOMA, OK 73102

(405) 525-2220

HEALTHCARE/MED

EQUIPMENT PLANNER

INNOVA GROUP

3196 N. SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT SECURITY

CONSULTANTS,

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

FOOD & BEVERAGE

PLANNER

STURM CONSULTING

5838 S. HUDSON PLACE

TULSA, OK 74135

(918) 260-0667

ENVIRONMENTAL

ENGINEER

RIVERFRONT ENVIRONMENTAL

1139 OLIVE STREET, STE 300

ST. LOUIS, MO 63101

(314) 436-9492

SPUR #: 2015

/5

/2

:3

:1

A

M

PHASING PLANS

NR 004 OF 221DLK

BID DOCUMENTS

ADDITION AND RENOVATION

OF CLC

09/06/2023

589-703

ROBERT J. DOLE VA MEDICAL CENTER

5500 EAST KELLOGG, BLDG. 60

WICHITA, KS 67218

GI012

N

1/16" = 1'-0"

PHASE 3 - DEMO - AREA B1

N

1/16" = 1'-0"

PHASE 4 - RENOVATION - AREA B2

PHASE DESCRIPTIONS & OVERVIEW PHASE 1 - DEMOLITION OF SITE WORK IN PREPARATION FOR THE NEW ADDITION

1. A CONSTRUCTION STAGING AREA WILL BE SET UP ADJACENT TO THE SITE ACROSS THE ROAD, PLAN EAST OF THE EXISTING BUILDING #60 FOOTPRINT. THERE IS AN EXISTING GRAVEL PARKING AREA THAT CAN BE USED FOR CONSTRUCTION STAGING.

2. THIS WILL INCLUDE THE DEMOLITION OF THE EXISING NORTH GARDEN AREA FOR THE CONSTRUCTION OF THE NEW ADDITION. ALL TREES, UTILITIES, STRUCTUES (WHICH INLCUDES THE EXISTING GAZEBO), AND SIDEWALKS ARE TO BE REMOVED.

3. THE EXISTING SMOKING PORCH ADJACENT TO THE EXISTING CAFETERIA ARE IN THE PT/OT AREA WILL BE DEMOLISHED. THE EXISTING BRICK, COLUMNS, WINDOWS, ROOF, AND STRUCTURE WILL BE REMOVED. THE CONTRACTOR WILL NEED TO PAY CLOSE ATTENTION IN KEEPING THE EXISTING INTERIOR WALLS AROUND THE SMOKING PORCH INTACT DURING THIS DEMOLITION, SINCE THESE WALLS AND ASSOCIATED ELEMENTS WILL BE SAVED. CONTRACTOR TO PREP ANY EXTERIOR SURFACES THAT ARE EXPOSED IN THEIS AREA AFTER

DEMOLITION TO BE WEATHER RESISTANT.

4. SOME ADDITIONAL DEMOLITION WILL NEED TO TAKE PLACE IN SOME OF THE EXISTING EAST WING SO AS TO REMOVE EXISTING UTILITIES AND BRING IN NEW UTILITIES. THE AREAS AFFECTED WILL NEED ICRA BARRIERS AND EXTERIOR BARRIERS TO PROTECT THE ADJACENT AREAS THAT NEED TO REMAIN FUNCTIONAL DURING CONSTRUCTION AND TO PROTECT STAFF AND THE PATIENTS.

PHASE 2 - NEW CONSTRUCTION OF CLC ADDITION.

1. ONCE THE DEMOLITION OF THE EXTERIOR AREA TO THE NORTH OF THE EXISTING EAST

WING AND SMOKING PORCH HAS BEEN COMPLETED THEN NEW CONSTRUCTION CAN

COMMENCE. NEW UTILITIES WILL BE INSTALLED AND NEW STRUCTURAL FOOTING,

GRADE BEAMS AND SLABS WILL BE PLACED. NEW STEEL COLUMNS AND BEAMS WILL

BE INSTALLED PRIOR TO ROOFING AND EXTERIOR ENVELOPE INSTALLATION.

2. ONCE THE BUILDING IS ENCLOSED THE INTERIOR STUD WALLS CAN PUT UP AND DOORS

AND FRAMES CAN BE INSTALLED. MEP CAN START TO RUN DUCTWORK, PIPING,

CABLING, AND ANY OTHER ITEMS THROUGHTOUT THE NEW ADDITION.

3. ALL FINISHES TO BE INSTALLED ONCE ALL THE INTERIOR WALLS ARE UP AND IN PLACE.

CASEWORK INSTALLATION CAN OCCUR ALONG WITH FINISHES.

4. ONCE CASEWORK AND FINISHES HAVE BEEN INSTALLED, THEN ALL MEDICAL

EQUIPEMENT AND FURNISHINGS CAN BE INSTALLED.

PHASE 3 - DEMOLITION OF EXISTING CLC ROOMS AND SPACES TO BE RENOVATED.

1. ONCE THE NEW ADDITION HAS BEEN FINISHED AND ACCPETED BY THE VA FOR USE, THEN THE EAST

WING AND PORTION OF THE SOUTH WING OF THE EXISTING BUILDING #60 CAN START TO BE

DEMOLISHED. THIS INCLUDES BUT IS NOT LIMITED TO: FLOOR SLABS AS SPECIFIED FOR NEW UTILITIES, INTERIOR STUD WALLS, DOORS AND FRAMES, CEILINGS, AND MEP ITEMS. THE CONTRACTOR WILL BE

RESPONSIBLE TO PROTECT ALL ADJACENT AREAS THAT ARE TO REMAIN IN OPERATION DURING

DEMOLITION SO AS TO PROTECT THE STAFF AND PATIENTS. THE CONTRACTOR WILL COORDINATE ALL

ICRA BARRIERS AS NEEDED.

2. IN ADDITION TO THE EAST AND SOUTH WING DEMOLITION, THE EXISTING ENTRY LOBBY AREA WILL NEED TO BE UPDATED. DEMOLITION OF THIS AREA INCLUDES THE FOLLOWING ITEMS, BUT IS NOT LIMITED TO:

STUD WALLS, DOORS AND FRAMES, CEILINGS, AND MEP ITEMS AS NEEDED TO BE REMOVED. DURING THIS TIME, A NEW EXTERIOR VESTIBULE WILL BE CONSTRUCTED WHICH WILL ENTAIL THE REMOVAL OF

SOME OF THE EXTERIOR FINISHES. THE CONTRACTOR WILL BE REPSONSIBLE TO PROTECT ALL

ADJACENT AREAS THAT ARE TO REMAIN IN OPERATION DURING DEMOLITION TO PROECT THE STAFF

AND PATIENTS. THE CONTRACTOR WILL COORDINATE ALL ICRA BARRIERS AS NEEDED.

PHASE 4 - RENOVATION OF THE EXISTING CLC

1. ONCE THE DEMOLITION OF THE EXTERIOR AREA TO THE NORTH OF THE EXISTING EAST WING AND SMOKING PORCH HAS BEEN COMPLETED THEN NEW CONSTRUCTION CAN COMMENCE. NEW CONSTRUCTION WIL INCLUDING THE FOLLOWING, BUT NOT LIMITED TO: NEW STUD WALLS, DOORS AND FRAMES, CEILINGS, AND MEP RELATED PIPING, DUCTWORK, AND CABLING. THE CONTRACTOR WILL BE RESPONSIBLE FOR PROTECTION OF ALL ADJACENT AREAS THAT ARE TO REMAIN IN OPERATION DURING NEW CONSTRUCTION TO PROJECT THE STAFF AND PATIENTS. THE CONTRACTOR WILL COORDINATE ALL ICRA BARRIERS AS NEEDED.

2. ONCE THE WALLS AND ASSOCIATED MEP ITEMS HAVE BEEN INSTALLED THEN WALL, FLOOR AND CIELING FINISHES CAN BE INSTALLED. MILLWORK INSTALLATION CAN

OCCUR ALONG WITH FINISHES.

3. ONCE THE MILLWORK AND FINISHES HAVE BEEN INSTALLED, ALL MEDICAL EQUIPMENT AND FURNISHINGS CAN BE INSTALLED.

4. IN ADDITION TO THE EAST AND SOUTH WING NEW CONSTRUCTION, THE EXISTING ENTRY LOBBY AREA WILL NEED TO BE UPDATED WITH A NEW LAYOUT. NEW CONSTRUCTION OF THIS AREA WILL NEED TO BE DONE WHICH INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING ITEMS: STUD WALLS, DOORS AND FRAMES, CEILINGS, AND MEP ITEMS AS NEEDED TO BE INSTALLED. FURTHERMORE, DURING THIS TIME, A NEW EXTERIOR VESTIBULE WILL ENTAIL THE ADDITION OF NEW STRUCTURAL STEEL AND NEW EXTERIOR WALLS AND FINISHES. THE CONTRATOR WILL BE RESPONSIBLE FOR PROTECTION OF ALL ADJACENT AREAS THAT ARE TO REMAIN IN OPERATION DURING NEW CONSTRUCTION SO AS TO PROTECT THE STAFF AND THE PATIENTS. THE CONTRACTOR WILL COORDINATED ALL ICRA BARRIERS AS NEEDED.

PHASE 1 SCOPE

• DEMOLITION OF SITE WORK IN

PREPARATION FOR THE NEW ADDITION.

PHASE 2 SCOPE

• NEW CONSTRUCTION OF CLC ADDITION.

PHASE 3 SCOPE

• DEMOLITION OF THE EXISTING CLC ROOMS

AND SPACES TO BE RENOVATED.

PHASE 4 SCOPE

• RENOVATION OF THE EXISTING CLC.

FD

FD

FD

FD

FD

FD

OCCUPANCY AREA LEGEND

ASSEMBLY - FIXED SEATING

ASSEMBLY - LESS CONCENTRATED USE, WITHOUT FIXED SEATING

ASSEMBLY, KITCHENS

BUSINESS

HEALTHCARE - SLEEPING DEPARTMENTS

STORAGE USE, OTHER

BATH

152A

RESIDENT

BATH

151A

RESIDENT

CORRI…