The drawings provide details on the mechanical, electrical, and plumbing systems for the renovation and addition project, including plans for the building's HVAC system, piping, ductwork, and utility yard. Key details include the installation of a new temporary boiler system and HVAC unit to serve the hospice area during construction, demolition of existing HVAC equipment, and routing of new heating water, chilled water, and natural gas piping. The drawings also show layouts for the building's various rooms and spaces, as well as plans for exhaust fans, air terminal units, and other mechanical equipment. No specific deadline, pricing, or set-aside information is provided in these drawings.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E9A
E8A
E7
EH
P
EJ
EK
E6 E8E4 E5 5.5E10E94 5
TEMP BOILER
LAYDOWN LOCATION
"ø
S A
"x
R A
"x
R A
"ø
S A 8"x8" EA
8" x6
E
A 8" x6
E A
10"ø SA
12"x6" RA
"x
R A
12"x12" RA
8"x6" EA 8"x6" EA
"x
8" E
A
14"ø SA 12"ø SA
"ø
S A
"ø
S A
"x
8" R
A
8" x6
E
A
8"x6" EA
8" ø
S A
8" x8
R
A
8"x6" EA
"x
8" E
A
8"x6" EA 8"x8" EA
8" ø
S A
8" x6
R
A
8" x6
E
A
10"ø SA
12"x12" RA 10"x8" RA
"x
6" R
A
10"ø SA
8" ø
S A
8"ø SA
8"ø SA
"x
6" R
A
8" x6
E
A
8" ø
S A
"x
6" R
A
10"x6" RA
"ø
S A12"x6" RA
12"x6" RA8"x6" RA
8"x8" EA14"x8" EA
"x
6" E
A
"x
8" E
A
"x 8"
E A
8"x6" EA 8"x6" EA
12"x6" RA
12"x6" RA
8" ø
S A
8"x6" EA
8" x6
E
A 8" x6
E A
"ø
S A
EXISTING
VAV
8" ø
S A
1/
4" H
H R
1/
2" H
H S
1/
4" H
H R
1/
2" H
H S
1 1/4" HHS
1 1/4" HHR
1 1/4" HHS
1 1/4" HHR
1 1/4" HHS
1 1/2" HHR 1 1/2" HHR
1 1/4" HHS 1 1/4" HHS
1 1/2" HHR
1" H
H S
1/
2" H
H R
1/
4" H
H S
1" H
H S
1/
2" H
H R
1" HHS
1" HHS
1 1/2" HHR
1/
2" H
H R
1" H
H S
TEMPORARY SA
TEMPORARY RA
14"ø
18"ø
22"ø
TEMP HHR
TEMP HHS
CONNECT TO
TEMP UNIT
HOSPICE
AREA
18"x10" RA
1/
2" H
H S
TEMP AHU LAYDOWN
LOCATION
16"ø
20"ø
24"ø
EXISTING
VAV
EXISTING
VAV
EXISTING
VAV
EXISTING
VAV
EXISTING
VAV
EXISTING
VAV
EXISTING
VAV
EXISTING
VAV
EXISTING
VAV
EXISTING
VAV
EXISTING
VAV
NATURAL GAS
FLEXIBLE HOSE
T1
T1
T1 T2
T3 T3
T4
"ø
EXISTING
VAVS
2 1/2" NATURAL GAS
PIPING
2 BED
TLC ROOM
1B106
DOCTORS
OFFICE
1B119
2 BED
TLC ROOM
1B121
BREAK
ROOM
1B122
CONGREGATE
BATH
1B120
TLC
KITCHENETTE
1B146
2 BED
TLC ROOM
1B144
2 BED
TLC ROOM
1B145
2 BED
TLC ROOM
1B147
PSCHOLOGIST
1B123
SOCIAL
WORKER
1B143
TOILET
1B144A
TOILET
1B121A
LAUNDRY
1B151
TOILET
1B147A
MED
SUPPLY
1B152
COMPUTER
CHARGING
1B153
TOILET
1B108A
TOILET
1B106A
SOILED
UTILITY
1B104
CLEAN
LINEN
1B117
CLOSET
1B102
BARBER
1B118
TLC
MEDICATION
1B149
STAFF
TOILET
1B150
TOILET
1B120A
TLC NURSE
0-STATION
CORRIDOR
0-CORR-B1
"x
R A
44"x12" RA
"x
S A
"x
R A
"x
R A
"ø
S A
CONNECT TO
TEMP UNIT
TEMPORARY BARRIER, REFER TO
ARCH. FOR MORE INFORMATION
T5
T5
T6
T6
T6
T6
T6
EI
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
SPUR #: 2015
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF
PROJECT SCOPE SHOWN. REFERENCE GI011 & GI012 - PHASING PLANS
FOR MORE INFORMATION
/3
/2
:5 :0
P
M
MECHANICAL TEMPORARY PLAN
RDC 158 OF 229CMT
BID DOCUMENTS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
MT101
N
1/8" = 1'-0"
MECHANICAL TEMPORARY PLAN1
HOSPICE AREA
RECOMMENDED TEMPORARY SYSTEMS PHASING NOTES:
1. FURNISH AND INSTALL 2-1/2” NATURAL GAS PIPING TO LOCATION SHOWN AND TERMINATE WITH A T-FITTING AND 2 SHUT-OFF VALVES. REFER TO PLUMBING SHEET PS201 FOR CONNECTION POINT. CONTRACTOR SHALL CONNECT A TEMPORARY NATURAL GAS PIPE TO THE SHUTOFF VALVE AS SHOWN AND ROUTE THROUGH THE CONSTRUCTION AREA AND CONNECT TO THE TEMPORARY TRAILER-MOUNTED BOILER SYSTEM. THE TEMPORARY NATURAL GAS PIPE
SHALL BE SIZED TO MEET THE TEMPORARY BOILER MANUFACTURER’S WRITTEN INSTRUCTIONS.
2. CONTRACTOR SHALL FURNISH A TEMPORARY, TRAILER-MOUNTED, PACKAGED BOILER SYSTEM COMPLETE WITH CIRCULATING PUMP AND ACCESSORIES. TEMPORARY PACKAGED BOILER SYSTEM SHALL HAVE THE FOLLOWING
PERFORMANCE:
TOTAL HEATING CAPACITY: 200 MBH
LEAVING WATER TEMPERATURE: 180°F
TOTAL WATER FLOW: 10.5 GPM
3. CONTRACTOR SHALL FURNISH A TEMPORARY, TRAILER-MOUNTED, PACKAGED HVAC SYSTEM CAPABLE OF THE
FOLLOWING PERFORMANCE:
TOTAL COOLING CAPACITY: 120 MBH
TOTAL SUPPLY AIR: 3,125 CFM
OUTDOOR AIR: 625 CFM
LEAVING AIR TEMPERATURE: 55°F DB / 54°F WB
4. THE CONTRACTOR SHALL REMOVE SECTIONS OF THE EXISTING SUPPLY AIR AND RETURN AIR DUCTWORK TO DISCONNECT THE MAIN SUPPLY AIR AND MAIN RETURN AIR DUCTWORK SERVING THE HOSPICE AREA FROM THE MAIN DISTRIBUTION SYSTEM AS SHOWN. CONTRACTOR SHALL CAP AND SEAL BOTH ENDS OF THE SUPPLY AIR AND RETURN DUCTWORK AND PREPARE THE SUPPLY AIR AND RETURN AIR DUCTWORK SERVING THE HOSPICE AREA FOR
TEMPORARY FLEXIBLE DUCTWORK CONNECTIONS.
5. CONTRACTOR SHALL ROUTE FLEXIBLE SUPPLY AIR DUCTWORK AND FLEXIBLE RETURN AIR DUCTWORK THROUGH THE CONSTRUCTION AREA AND CONNECT TO EXISTING SUPPLY AIR AND RETURN AIR DUCTWORK SERVING THE HOSPICE
AREA AS SHOWN. THE FLEXIBLE DUCTWORK SHALL BE SIZED AS SHOWN.
6. THE CONTRACTOR SHALL REMOVE SECTIONS OF THE EXISTING HEATING WATER SUPPLY AND HEATING WATER RETURN PIPING TO DISCONNECT THE MAIN HEATING WATER SUPPLY AND RETURN PIPING SERVING THE HOSPICE AREA FROM THE MAIN DISTRIBUTION SYSTEM AS SHOWN. CONTRACTOR SHALL CAP AND SEAL BOTH ENDS AND PREPARE THE MAIN HEATING WATER PIPING SERVING THE HOSPICE AREA FOR TEMPORARY PIPING CONNECTIONS.
7. CONTRACTOR SHALL ROUTE TEMPORARY HEATING WATER SUPPLY AND RETURN PIPING FROM THE TEMPORARY, TRAILER-MOUNTED, PACKAGED BOILER SYSTEM AND CONNECT TO THE EXISTING HEATING WATER PIPING AS SHOWN.
8. THE CONTRACTOR SHALL INTEGRATE CONTROL OF THE EXISTING VAV BOXES SERVING THE HOSPICE AREA WITH THE
TEMPORARY PACKAGED HVAC SYSTEM.
KEYNOTES
T1 CAP AND SEAL EXISTING HEATING WATER SUPPLY AND RETURN PIPING DURING CONSTRUCTION.
T2 CONNECT TEMPORARY HEATING WATER SUPPLY AND RETURN PIPING TO EXISTING PIPING SERVING HOSPICE AREA.
T3 CONNECT TEMPORARY SUPPLY AND RETURN DUCTWORK TO EXISTING DUCTWORK SERVING HOSPICE AREA.
T4 CONNECT TEMPORARY NATURAL GAS PIPING TO SHUTOFF VALVE AT LOCATION SHOWN. CONNECT TO TEMPORARY BOILER
SYSTEM.
T5 LOCATE TEMPORARY UNITS AS CLOSE TO BUILDING #60 AS POSSIBLE, WITHOUT IMPEDING ENTRANCE INTO BUILDING #59.
MAINTAIN REQUIRED EQUIPMENT CLEARANCE SPACE.
T6 EXISTING DUCTWORK TO REMAIN. REFER TO MECHANICAL DEMOLITION SHEET MD101.
PLAN AREA
GENERAL NOTES:
1. CHANGEOVER OF TEMPORARY UTILITIES SHALL OCCUR OVER A 2 HOUR TIME FRAME AND SHALL BE COORDINATED
WITH THE VA.
No. REVISION DESCRIPTION DATE
26"x14" 46"x16" SA
60"x16" SA
60"x14" RA
"x
R A
44"x12" RA
D1D1 D1 D1
D1D1D1D1D1D1D1D1
D1
D1
D1
D1
D1
D1 D1
D1
D1
D1
D1
D1
D1 D1
D1
D1
D1 D1
D2
D2
D2
D2
D2
D2
D2 D2
D2
D2
D2
D2
D2
D2
D2 D2
D2D2 D2 D2
D2 D2 D2
D2
D1
D2
D2
D3
D3D3 D3
D3 D3 D3 D3
D3 D3
D3
D2
D3
D3D3
D3
D3
D3
D2
D2
D2
D3
D3
D3
D4
2 BED
TLC ROOM
1B116
2 BED
TLC ROOM
1B114
2 BED
TLC ROOM
1B112
2 BED
TLC ROOM
1B110
2 BED
TLC ROOM
1B108
2 BED
TLC ROOM
1B106
2 BED
TLC ROOM
1B1152 BED
TLC ROOM
1B113
2 BED
TLC ROOM
1B111
2 BED
TLC ROOM
1B109
2 BED
TLC ROOM
1B107
2 BED
TLC ROOM
1B105OPEN
OFFICE
1B103
OFFICE
1B103A
COPY
1B103B
TOILET
1B105A
TOILET
1B109A
TOILET
1B113A
CONFERENCE
ROOM
1B101
ACTIVITIES
ROOM
1B100
TOILET
1B101A
DOCTORS
OFFICE
1B119
2 BED
TLC ROOM
1B121
BREAK
ROOM
1B122
CONGREGATE
BATH
1B120
TLC
KITCHENETTE
1B146
2 BED
TLC ROOM
1B144
2 BED
TLC ROOM
1B145
2 BED
TLC ROOM
1B147
PSCHOLOGIST
1B123
SOCIAL
WORKER
1B143
TOILET
1B144A
TOILET
1B121A
LAUNDRY
1B151
TOILET
1B147A
MED
SUPPLY
1B152
COMPUTER
CHARGING
1B153
TOILET
1B114A
TOILET
1B110A
TOILET
1B108A
TOILET
1B106A
SOILED
UTILITY
1B104
CLEAN
LINEN
1B117
CLOSET
1B102
BARBER
1B118
TLC
MEDICATION
1B149
STAFF
TOILET
1B150
TOILET
1B120A
TLC NURSE
0-STATION
CORRIDOR
0-CORR-B1
OFFICE
1B100B
OXYGEN
OPEN
OFFICE
OFFICE
101B
TOILET
1B100A
14"x8"
18"x8"
8"x8" 8"x6"
8"x8"
18"ø SA
24"x12"
26"x12" RA
30"x12" RA
14"ø
"x
S A
14"ø
10"ø12"ø 8"ø14"x60" RA
UP TO 60-
AHU-2
D116"x60" SA
UP TO 60-
AHU-2
12"ø 8"ø14"ø
"x
24"x12" 20"x12"
12"x8"16"x12"
"x
R A
24"x10" RA
"x
R A
14"x10"
12"x10"
"ø
NOT IN SCOPE
NOT IN SCOPE
10"ø
"x
6"
"ø
14"ø
D1
D1
"x
S A
"x
8" E
A
8"x8" 8"x8" EA
8"x6"
16"ø
"x
8" E
A
"ø
S A
14"x6"
8"x6"
D1
8"x6"
8"ø
8"x6"
8"x6"
D1
D2
D2
8"x6"
E12E11
E9AE8A
E13 E7
EH
P
EJ
EK
E6 E8 E2 E4 E5
EG
EF
EE
ED
E1 E3
EF1
E10E9
D1
D1
12"ø SA
CAP EXHAUST
EI
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
B
SPUR #: 2015
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF
PROJECT SCOPE SHOWN. REFERENCE GI011 & GI012 - PHASING PLANS
FOR MORE INFORMATION
/3
/2
:4 :5
P
M
MECHANICAL HVAC DEMOLITION PLAN
RDC 159 OF 229CMT
BID DOCUMENTS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
MD101
N
1/8" = 1'-0"
MECHANICAL DEMOLITION PLAN1
DEMOLITION KEYNOTES
D1 DEMOLISH EXISTING VAV BOX, REHEAT COIL, ASSOCIATED MEDIUM AND LOW PRESSURE DUCTWORK, AIR DEVICES, THERMOSTAT, CONTROL WIRING AND ASSOCIATED ACCESSORIES. CAP SUPPLY AIR DUCT AT MAIN.
D2 DEMOLISH EXISTING RETURN AIR DEVICE AND DUCT BACK TO DEMARCATION POINT AND CAP EXISTING DUCT.
D3 DEMOLISH EXISTING EXHAUST AIR DEVICE AND DUCT BACK TO DEMARCATION POINT AND CAP EXISTING DUCT.
D4 DEMOLISH EXISTING DUCT ELBOW. DUCT DROP THROUGH ROOF SHALL REMAIN FOR REUSE.
D5
D5
D5
D5
D5
D5
D5
D5
D5
D5
D5
D5
D5
D5 D5 D5 D5 D5 D5 D5 D5
D5D5D5D5
D5
D5D5
D5
D5
D5 D5
D5
D5
D5
D5
2 BED
TLC ROOM
1B116
2 BED
TLC ROOM
1B114
2 BED
TLC ROOM
1B112
2 BED
TLC ROOM
1B110
2 BED
TLC ROOM
1B108
2 BED
TLC ROOM
1B106
2 BED
TLC ROOM
1B115
2 BED
TLC ROOM
1B113
2 BED
TLC ROOM
1B111
2 BED
TLC ROOM
1B109
2 BED
TLC ROOM
1B107
2 BED
TLC ROOM
1B105
OPEN
OFFICE
1B103
OFFICE
1B103A
COPY
1B103B
TOILET
1B105A
TOILET
1B109A
TOILET
1B113A
CONFERENCE
ROOM
1B101
ACTIVITIES
ROOM
1B100
TOILET
1B101A
DOCTORS
OFFICE
1B119
2 BED
TLC ROOM
1B121
BREAK
ROOM
1B122
CONGREGATE
BATH
1B120
TLC
KITCHENETTE
1B146
2 BED
TLC ROOM
1B144
2 BED
TLC ROOM
1B145
2 BED
TLC ROOM
1B147
PSCHOLOGIST
1B123
SOCIAL
WORKER
1B143
TOILET
1B144A
TOILET
1B121A
LAUNDRY
1B151
TOILET
1B147A
MED
SUPPLY
1B152
COMPUTER
CHARGING
1B153
TOILET
1B114A
TOILET
1B110A
TOILET
1B108ATOILET
1B106A
SOILED
UTILITY
1B104
CLEAN
LINEN
1B117
CLOSET
1B102
BARBER
1B118
TLC
MEDICATION
1B149
STAFF
TOILET
1B150
TOILET
1B120A
TLC NURSE
0-STATION
CORRIDOR
0-CORR-B1
OFFICE
1B100B
OXYGEN
OPEN
OFFICE
OFFICE
101B
TOILET
1B100A
2" HHS
3/4" MPS
2" H
H R
1" H
H S
2" H
H R
2" HHR
3/4" HHS
1" H
H S
1 1/2" HHR
1 1/2" HHR
1" HHS
1 1/4" HHR
1 1/4" HHS
1/
4" H
H R
1/
4" H
H S
1 1/4" HHS
1 1/4" HHR
3/ 4"
3/ 4"
1 1/2" HHS1 1/2" HHS
1" HHR
1/
2" H
H S
3/ 4"
3/4"
3/4"
3/ 4"
M P
S
3/4" HHR
2" HHS
3/4" MPS
3/ 4"
3/ 4"
H H
R3/ 4"
H H
S
2" H
H R
2" H
H S
2" H
H S
3/4" 3/4"
3/ 4"
3/ 4"
3/ 4"
1/
4" H
H R
1/
2" H
H S
3/4" HHS
2" HHR
1" HHS
2" H
H R
1/
2" H
H R
1" H
H S
NOT IN SCOPE
NOT IN SCOPE
2" HHR
3/4" HHR
E12E11
E9AE8A
E13
E7
EH
P
EJ
EK
E6 E8
E2 E4 E5
EG
EF
EE
ED
E1 E3
E10E9
D5
D5
D6
D6
D6 D6
EI
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
B
SPUR #: 2015
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF
PROJECT SCOPE SHOWN. REFERENCE GI011 & GI012 - PHASING PLANS
FOR MORE INFORMATION
/3
/2
:5 :0
P
M
MECHANICAL PIPING DEMOLITION PLAN
RDC 160 OF 229CMT
BID DOCUMENTS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
MD102
DEMOLITION KEYNOTES
D5 DEMOLISH EXISTING HEATING WATER SUPPLY AND RETURN BRANCH PIPING BACK TO DEMARCATION POINT AND CAP AT
MAIN. REFER TO MH-101 FOR DEMOLITION OF VAV BOX AND REHEAT COIL.
D6 DEMOLISH SECTION OF HEATING WATER SUPPLY AND HEATING WATER RETURN PIPING TO POINT SHOWN TO ALLOW FOR CONNECTION TO TEMPORARY BOILER SYSTEM. REFER TO SHEET MT101 FOR MORE INFORMATION.
N
1/8" = 1'-0"
MECHANICAL PIPING DEMOLITION PLAN1
GENERAL NOTES
1. HEATING WATER SYSTEM SERVES ADJACENT HOSPICE AREA. ALL SHUTDOWNS OR DISRUPTIONS OF SERVICE
REQUIRE ADVANCED NOTICE AND SHALL BE COORDINATED WITH THE VA.
RTU-1 60-EF5
60-EF7
RH-2
RH-1
60-EF10
60-EF8
60-EF6
60-ACC-1
60-ACC-2
60-EF3
60-EF4 D12
D12
4" C
H R
4" C
H S
4" H
H S
4" H
H R
4" HHR
4" HHS
4" CHS
4" CHR
(4) CHILLED WATER AND
HEATING WATER PIPES
DN. TO SERVE BLDG. 59
MD104
6" CHR
6" CHS
E12E11
E9AE8A
E13
E7
EH
P
E6 E8
E2 E4
EG
EF
EE
ED
EB1
E1 E3
E10E9
EXISTING LAUNDRY
EXHAUSTS
EI
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
B
SPUR #: 2015
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF
PROJECT SCOPE SHOWN. REFERENCE GI011 & GI012 - PHASING PLANS
FOR MORE INFORMATION
/3
/2
:5 :0
P
M
MECHANICAL ROOF DEMOLITION PLAN
RDC 161 OF 229CMT
BID DOCUMENTS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
MD103
N
1/8" = 1'-0"
MECHANICAL ROOF DEMOLITION PLAN1
DEMOLITION KEYNOTES
D12 REMOVE EXISTING EXHAUST FAN, ACCESSORIES, AND CURB. EXISTING EXHAUST DUCTWORK RISER TO BE RE-USED.
REFER TO MECHANICAL ROOF PLAN ON SHEET MH201.
60-AHU-1 60-AHU-2
D7
D10
D10
60-HWP-1
60-HWP-2
HWP-59-1
HWP-59-2
C-59-2
C-59-1
CWP-60-2
CWP-60-1 D7
60-ET-2 D8
60-C-1
60-C-2
D9
D9
60-ET-1
60-AS-1
D8
D11
30"x16" RA
36"x18" SA
RF-1
30"x16" RA
30"x16" RA
30"x16" RA
96"x48" OA 38"x22" RA
RF-2
48"x18" RA
36"x24" SA
36"x24" SA 36"x18" SA
36"x18" SA
30"x16" RA DN.36"x18" SA DN.
1 1/4" HHS
4" LPS
1 1/2" LPC
1 1/2" MPS
2" MPS
1 1/2" LPC
3"
M P
S
2" MPS
1" M
P S
3" H
H S
3" H
H R
1" M
P S
4" H
H R
4" H
H S
4" C
H R
4" H
H R
4" C
H S
4" H
H S
1" MPS
4" CHR
6" CHR
40"x20" RA
1" M
P S
1/
2" L
P C
6" C
H S
6" C
H R
2" MPS
1/
4" M
P S
4" DR
4" CHR
4" CHS
4" C
H R
"x
R A
OA LOUVEROA LOUVEROA LOUVER
2" V
1/
2" L
P C
4" HHR
6" C
H R
4" C
H R
6" CHR 4" CHR
FLASH
TANK
RA LOUVER TO
REMAIN
DOWN TO B60 WING B
DOWN TO B60 WING A
STEAM PRESSURE
REDUCING STATION
AIR SEPARATOR
CONDENSATE
RETURN PUMP
EXHAUST FAN
AND LOUVER
RA LOUVER
E7E4 E5
EE
ED
E3
J th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
B
SPUR #: 2015
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF
PROJECT SCOPE SHOWN. REFERENCE GI011 & GI012 - PHASING PLANS
FOR MORE INFORMATION
/3
/2
:5 :0
P
M
MECHANICAL PENTHOUSE DEMOLITION
PLAN
RDC 162 OF 229CMT
BID DOCUMENTS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
MD104
N
1/4" = 1'-0"
MECHANICAL PENTHOUSE DEMOLITION PLAN1
DEMOLITION KEYNOTES
D7 REPLACE EXISTING CHILLED WATER PUMPS WITH NEW PUMPS PER NEW WORK DRAWINGS. COORDINATE REMOVAL AND REPLACEMENT OF PUMP WITH OWNER AND BUILDING'S OPERATIONAL SCHEDULE TO ENSURE THE SYSTEM IS
OPERATIONAL WHEN NECESSARY.
D8 REPLACE EXISTING EXPANSION TANK WITH NEW TANK PER NEW WORK DRAWINGS. COORDINATE REMOVAL AND REPLACEMENT OF TANK WITH OWNER AND BUILDING'S OPERATIONAL SCHEDULE TO ENSURE THE SYSTEM IS
OPERATIONAL WHEN NECESSARY.
D9 REPLACE EXISTING HEATING WATER PUMPS WITH NEW PUMPS PER NEW WORK DRAWINGS. COORDINATE REMOVAL AND REPLACEMENT OF PUMP WITH OWNER AND BUILDING'S OPERATIONAL SCHEDULE TO ENSURE THE SYSTEM IS
OPERATIONAL WHEN NECESSARY.
D10 REPLACE EXISTING STEAM TO HEATING WATER HEAT EXCHANGERS WITH NEW HEAT EXCHANGERS PER NEW WORK DRAWINGS. COORDINATE REMOVAL AND REPLACEMENT OF HEAT EXCHANGERS WITH OWNER AND BUILDING'S
OPERATIONAL SCHEDULE TO ENSURE THE SYSTEM IS OPERATIONAL WHEN NECESSARY.
D11 REPLACE EXISTING AIR SEPARATOR WITH NEW SEPARATOR PER NEW WORK DRAWINGS. COORDINATE REMOVAL AND REPLACEMENT OF SEPARATOR WITH OWNER AND BUILDING'S OPERATIONAL SCHEDULE TO ENSURE THE SYSTEM IS
OPERATIONAL WHEN NECESSARY.
FSD
S D
S D
S D
S D
S D
S D
S D
S D S D
SD
SD
SD SD
SD
S D
SD S
D
S D
SD
S D
SDSD
SDSD
SDSD
S
D SD
SD SD
S D
SDSD
S D
SD SD
S D
SDSD
S D
SDSD
S D
S D
S D
S D
SDSD
S D
S D
S D
S D
SD
SD
SD SD
S D
SD
SD
S D
S D
FD FD
FD
FD
FD
FD
FD
FD
S D
SD
ELECTRICAL
FIRE RISER ROOM
115A
IT ROOM
BATHING ROOM
117 TOILET
117A
SOILED UTILITY
CLEAN UTILITY
BATH
119A
BARIATRIC RESIDENT
ROOM
RESIDENT ROOM
RESIDENT ROOM
BATH
122A
BATH
121A
RESIDENT ROOM
RESIDENT ROOM
BATH
134A
BATH
135A
RESIDENT ROOM
BATH
136A
BATH
139A
RESIDENT ROOM
RESIDENT ROOM
BATH
140A
BATH
142A
RESIDENT ROOM
RESIDENT ROOM
BATH
143A
DEN
BATH
145A RESIDENT ROOM
RESIDENT ROOM
STAFF LOUNGE
149TOILET
DINING
133B
HSKPG
PANTRY
KITCHEN
LIVING ROOM
133A
TOILET
ART ROOM-1
HOME STORAGE
HOUSE LAUNDRY
MP STORAGE
132A
RESIDENT ROOM
BATH
137A
RESIDENT ROOM
BATH
138A
RESIDENT ROOM
BATH
141A
CONF. / PRIVATE DINING
REC THERAPY OFFICE
MED
BATH
151A
RESIDENT ROOM
RESIDENT ROOM
BATH
152A
CORRIDOR
CORRIDOR
LIVING ROOM
166A
MULTIPURPOSE/
ACTIVITY ROOM-1
132-A
MULTIPURPOSE/
ACTIVITY ROOM-2
132-2
EQ STORAGE
HAC
VEST
006A
12"x10" EA
12"x10" EA UP
TO 60-EF 13
"x
S A
"x
S A
10"x10" SA
30"x16" SA32 "x
S A
10"x8" EA
12"x10" EA
8"x6" EA 12"x12" EA
14"x12" EA 8"x6" EA
10"x8" EA
"x
R A
"x
S A
16"x16" EA UP
TO 60-EF-12
(1300 CFM) ON
ROOF
20"x50" SA UP
TO 60-AHU-3
32"x36" RA UP
TO 60-AHU-3
60-VAV-69
60-VAV-68
60-VAV-66
60-VAV-65
60-VAV-64
60-VAV-62
60-VAV-60
60-VAV-58
60-VAV-57
60-VAV-54
60-VAV-53
60-VAV-52
60-VAV-51
60-VAV-50
60-VAV-48
60-VAV-46 60-VAV-45
60-VAV-43
60-VAV-77
60-VAV-76
60-VAV-74
60-VAV-73
60-VAV-72
60-VAV-71
60-VAV-80
60-VAV-39
5.5
C
F
D
H
E
K
I
G
6.5
60-VAV-75
8"x6" EA
10"x10" EA 8"x6" EA
8"x6" EA
8"x6" EA
8"x6" EA
8"x6" EA
8"x6" EA
8"x6" EA
8"x6" EA8"x6" EA
8"x6" EA8"x6" EA
8"x6" EA
8"x6" EA
8"x6" EA 60-VAV-42
60-VAV-40
60-VAV-44
8"x6" EA
60-VAV-41
60-VAV-78
60-VAV-49
60-VAV-47
12"x12" RA
"x
S A
22"x12" RA
12"x12" EA
10"x10" EA
VEST
008A
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
60-VAV-37
60-VAV-38A
14"x12" SA
60-VAV-38C
60-VAV-38D
60-VAV-38B
10"x8" RA
HOME OFFICE-1
12"x14" EA
16"x16" EA, 1240
CFM UP TO EF-15
12"x12" EA
8"x6" EA
14"x12" EA
10"x8" EA
12"x12" EA UP TO
EF-16 ON ROOF
60-UH-1
A
87653
J
21 9
B
2.5 3.5
C.3
BATH
146A
8"x6" EA
8"x6" EA
8"x6" EA
"x
R A
8"x10" EA
"x
S A
14"x12" RA
10"x10" RA
24"x18" SA
"x
R A
22"x14" RA
60-FPVAV-4
60-FPVAV-3
10"x12" SA 10"x12" SA
8"ø RA 8"ø RA
8"ø RA
8"ø RA
8"ø RA
8"ø RA 10"ø SA
10"ø SA
10"x12" SA
10"x12" SA
"ø
S A
6"ø SA 8"ø RA
8"ø RA
10"ø SA
8"ø SA
12"ø SA
8"ø RA
8"x10" SA8"x10" SA 8"x10" SA
10"x12" SA
8"ø RA
10"ø RA
10"ø RA
8"ø RA8"ø RA
8"ø RA
30"x14" RA
24"x14" RA14"x12" RA
12"x10" SA
34"x34" RA
"x
R A
42"x14" RA
26"x14" RA
"x
R A
8"ø RA
14"x14" SA
14"x14" SA
8"ø RA
10"ø RA
8"x8" SA
6"x8" SA
10"x12" SA 8"ø SA
8"ø RA
8"ø RA
8"ø RA
8"x6" EA
10"ø SA 14"x10" RA
8"ø RA
8"ø RA8"ø RA
10"x12" SA 8"x10" SA
8"ø SA 8"ø SA
8"ø RA
10"x12" SA10"x12" SA
8"ø SA
8"ø SA
4"ø SA
6"ø SA
8"x10" SA
8"ø SA
8"x6" EA
18"x14" RA
10"x10" RA
8"ø SA
8"ø SA
8"ø SA
12"x12" SA
6"ø SA
8"ø SA
8"ø RA
6"ø SA
6"ø SA
10"ø RA
8"ø SA
8"ø SA 8"ø SA20"x14" RA
6"ø SA
6"ø SA
4"ø SA
6"ø SA
50"x20" SA
8" ø
S A
10"ø SA
10"ø SA
8"x10" SA
8"ø SA
8"ø SA
10"ø SA
6"ø SA
6"ø SA
8"ø SA
8"ø SA
8"ø SA
10"x10" SA
8"ø SA10"ø SA 8"ø SA
8"ø SA
6"ø SA
6"ø SA
6"ø SA
10"x12" SA
6"ø SA
8"ø SA
12"x10" SA
8"ø SA 8"ø SA 8"ø SA
8"ø SA
6"ø SA
4"ø SA
8"ø SA
TRANSFER
DUCT/GRILLE
4"ø SA
STEAM
DISPERSION
10"x12" SA
10"x12" SA
10"x12" SA
8"x10" SA 8"x10" SA
8"x10" SA
8"x8" SA
6"x8" SA
10"x12" SA
8"x12" SA
12"x8" SA
8"ø SA 8"ø SA
16"x12" RA
M-501
(TYP)
10"ø SA
10"ø SA
10"ø SA10"ø SA
10"ø SA
8"ø RA th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
KEY PLAN
A
N
SPUR #: 2015
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF
PROJECT SCOPE SHOWN. REFERENCE GI011 & GI012 - PHASING PLANS
FOR MORE INFORMATION
/3
/2
:5 :1
P
M
MECHANICAL HVAC DUCT PLAN - AREA
A
RDC 163 OF 229CMT
BID DOCUMENTS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
MH101
N
1/8" = 1'-0"
HVAC LEVEL 1 - DUCT PLAN - AREA A1
KEYNOTES
11 PROVIDE VAV BOX, ALL UPSTREAM MEDIUM PRESSURE DUCTWORK AND ACCESSORIES, AND CONTROLS DURING THE ADDITION PHASE OF CONSTRUCTION PHASE FOR LIVING ROOM 166A. LOW PRESSURE DUCTWORK AND AIR DEVICES WILL BE PROVIDED DURING THE RENOVATION PHASE. THERMOSTAT AND WIRING TO BE COILED AND HUNG FROM UNIT UNTIL
RENOVATION PHASE.
12 PROVIDE RETURN AIR DUCTWORK THROUGH NORTH WALL DURING THE ADDITION PHASE OF CONSTRUCTION PHASE FOR LIVING ROOM 166A. REMAINING DUCTWORK AND AIR DEVICE WILL BE PROVIDED DURING THE RENOVATION PHASE.
19 DUCT AND PIPE CROSSING SEISMIC JOINT REQUIRE BELLOWS AND FLEXIBLE CONNECTIONS, REFER TO M-501 DETAILS 8
AND 15 FOR MORE INFORMATION.
GENERAL NOTES:
1. PROVIDE SEISMIC BRACING ON DUCTWORK, PIPING, AND EQUIPMENT IN ACCORDANCE WITH VA STANDARD H-18-8, AND ASCE 7 CHAPTER 13. REFER TO STRUCTURAL DRAWINGS FOR ALL APPLICABLE SEISMIC CRITERIA.
SD
SD
SD
SD
SD
SD
SD
S D
SD
SD
S D
S D
S D
S D
S D
S D S
D
S D
S
DS
D
S D
S D
SD S
D
S D
S
DS
D
S D
S D
S D
S D
SD
S D
S D
SD
SD
SD
SDS
D
S D
S D
SD
S D
S D
S D
S D
S D
SD SD SD SDSD
S D
SD
SD
SD
SD
SD
S D
S D
SD S
D
S D
SD
SD
SD
S D
SD
S D
SD
12"x12" EA
12"x12" EA UP
TO 60-EF-4
12"x8" EA
18"x8" EA
10"x10" EA
18"x8" EA
44"x12" RA
60"x14" RA 44"x12" RA
18"x8" EA
46"x16" SA
"x
S A
"x
R A
"x
R A
"x
R A
"ø
S A
"x
R A
60-VAV-31
60-VAV-24
60-VAV-32
60-VAV-34
60-VAV-29
60-VAV-25
60-VAV-26
60-VAV-27
60-VAV-28
60-VAV-30
60-VAV-17
60-VAV-18
60-VAV-19
60-VAV-21
60-VAV-20
60-VAV-16
60-VAV-15
60-VAV-14 60-VAV-12
60-VAV-11
60-VAV-10
8"x8" EA
60-VAV-8
60-VAV-7
60-VAV-4
60-VAV-5
60-VAV-6
60-VAV-3
60-VAV-2
60-VAV-1
60-VAV-36
60-VAV-35
"x
R A
E12E11E9A
E8A
E13E7
EH
P
EJ
EK
E6 E8E2 E4 E5
EG
EF
EE
ED
E1 E3
EF1
E10E9
K
46"x16" SA
60-VAV-9A
10"x10" EA
8"x6" EA
8"x8" EA 8"x8" EA
60-VAV-13
60-FPVAV-2
"x
S A
60-VAV-9B
60-VAV-9E
8"x6" EA
8"x6" EA
8"x6" EA
TOILET
176A
TOILET
184A
BATHING ROOM
HOUSE LAUNDRY
172DIRECTORS OFFICE
184A
MED DIR OFFICE
EQUIP STORAGE
DEN
TEAM WORKROOM
TEAM WORKROOM
GEN STORAGE
SOILED LINEN
CLEAN LINEN
HAC
177 SW OFFICE
NRS LDR OFFICE
CLEAN UTILITY
SOILED UTILITY
CORRIDOR
BATH
175A
ELEC
RESIDENT ROOM
BATH
173A
02 FULL
167A
02 EMPTY
167B
HOUSE OFFICE
MEDICATION
RESIDENT ROOM
RESIDENT ROOM
161 RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
BATH
156A
BATH
158A
BATH
157A
BATH
159A
BATH
161A
BATH
163A
BATH
155A
RESIDENT ROOM
RESIDENT ROOM
BATH
153A
HAC
BATH
160A
BATH
162A
RESIDENT ROOM
RESIDENT ROOM
160RESIDENT ROOM
BATH
164A
DINING AREA
166B
KITCHEN
LIVING ROOM
166A
HSKPG
166D
PANTRY
166C
RESIDENT DINING
N&FS KITCHEN/SERVERY
131A
H. STORAGE
MOP
131B
10"x10" EA UP
TO 60-EF-2
12"x12" EA UP
TO 60-EF-17
18"x18" EA
UP TO EF-3
60-VAV-9C
8"x8" EA
8"x6" EA
30"x12" RA
10"x10" EA 12"x12" RA
22"x12" RA
WAITING
CORRIDOR
VESTIBULE
001A
PT/OT RECEP
100B
CLC RECEP
100A
60-VAV-83
60-VAV-84
SSTV
131C
"x
R A
12"ø SA
60-VAV-9D
20"x18" EA UP
TO 60-EF-18
NOT IN SCOPE
NOT IN SCOPE
60-KH-1
8"x6" EA
8"x8" EA
26"x14" SA 16"x14" SA
VESTIBULE
014A
14"ø EA
12"x12" EA
36"x8" SA
"x
S A
8"ø RA
8"ø RA
8"ø RA 8"ø RA
60-FPVAV-1
8"ø RA
8"ø RA 10"ø SA
12"x10" SA
12"x10" SA
"x
S A
10"ø RA
8"ø SA8"ø RA
8"ø SA
8"ø SA
8"ø RA
8"ø SA
8"ø SA
10"x12" SA
10"x14" SA
8"ø SA
14"x14" SA
12"ø SA
10"x12" SA12"x14" SA 12"x14" SA
8"x8" EA 8"x8" EA
10"x12" SA12"x14" SA
8"ø SA
8"x8" EA
8"x8" EA
10"ø RA 8"ø RA
10"ø RA
8"ø RA
10"x12" SA 10"x12" SA
12"x10" SA
8"ø SA
10"ø SA
8"ø SA
8"ø SA
8"ø RA
10"ø SA
12"x12" SA
6"ø SA
4"ø SA
8"ø RA
8"x10" SA 10"x12" SA
10"x12" SA
6"ø SA
4"ø SA
6"ø SA
16"x14" SA
4"ø SA
6"ø SA
6"ø SA
6"ø SA
4"ø SA
4"ø SA
10"x10" SA
8"ø SA 8"x10" SA
10"ø SA
12"ø SA
10"ø SA
4"ø SA
12"x10" SA
8"ø SA
10"ø SA 8"ø SA 8"ø SA
12"x10" SA
4"ø SA
8"ø SA
14"ø SA
12"x14" SA
12"x10" SA
4"ø SA
4"ø SA
10"ø SA
6"ø SA
12"x10" SA 10"x10" SA
8"ø SA 8"ø SA
6"ø SA 8"ø SA
8"x8" EA
8"ø SA
14"x14" SA
10"ø SA
26"x14" SA
8"ø SA
8"x10" SA
8"x10" SA
8"x6" EA
10"x10" SA
6"ø SA
4"ø SA 8"ø RA
8"ø RA
8"ø SA
8"ø RA
6"ø SA 8"ø SA
TRANSFER
GRILLES
6"x6" EA
6"x6" EA
8"x6" EA
10"x12" SA
10"ø SA
10"ø RA
8"ø SA 8"ø RA
12"x12" EA
8"ø RA
8"x8" EA
8"x6" EA
8"x10" SA
60-VAV-80
8"ø RA
8"ø RA
12"x10" SA
8"x6" EA
8"ø RA
8"x6" EA
10"ø SA
8"ø SA
8"x10" SA
10"ø SA
8"x12" SA
12"x10" RA
14"ø SA
22"x12" RA
24"x12" RA
18"ø SA
M-501
(TYP)
EI
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
KEY PLAN
B
N
SPUR #: 2015
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF
PROJECT SCOPE SHOWN. REFERENCE GI011 & GI012 - PHASING PLANS
FOR MORE INFORMATION
/3
/2
:5 :2
P
M
MECHANICAL HVAC DUCT PLAN - AREA
B
RDC 164 OF 229CMT
BID DOCUMENTS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
MH102
N
1/8" = 1'-0"
HVAC LEVEL 1 - DUCT PLAN - AREA B1
GENERAL NOTES:
1. PROVIDE SEISMIC BRACING ON DUCTWORK, PIPING, AND EQUIPMENT IN ACCORDANCE WITH VA STANDARD H-18-8, AND ASCE 7 CHAPTER 13. REFER TO STRUCTURAL DRAWINGS FOR ALL APPLICABLE SEISMIC CRITERIA.
KEYNOTES
13 GREASE EXHAUST DUCTWORK.
14 HOOD PROVIDED BY KITCHEN CONSULTANT. REFER TO KITCHEN CONSULTANT DRAWINGS FOR EXHAUST AND
MAKEUP AIR CONNECTIONS TO HOOD.
18 CONTRACTOR SHALL CAP EXISTING DUCTWORK AT LOCATION SHOWN.
19 DUCT AND PIPE CROSSING SEISMIC JOINT REQUIRE BELLOWS AND FLEXIBLE CONNECTIONS, REFER TO M-501
DETAILS 8 AND 15 FOR MORE INFORMATION.
60-EF6
60-EF10
60-EF8
60-EF7
60-EF5
60-ACC-1
60-ACC-2
RH-2RH-1
RTU-1
60-ACC-3
6" C
H S 6"
C H
R 4"
C H
S 4"
C H
R 4"
C H
S 4"
C H
R 4"
C H
R 4"
C H
S4" H
H S4" H
H R
EXISTING LAUNDRY
EXHAUST
E12E11
E9AE8A
E13
E7 E8
E2
E4 E5
EG
EF
EE
ED
EB
EB1
EA
E1 E3
EF1
E10E94
F
D
H
E
K
I
G
6.5
4" CHR
4" CHS
6" C
H S
6" C
H R
6" CHR
6" CHS
6" C
H R
6" C
H S
6" CHS
6" CHR
60-MUA-1
60-EF-18
60-EF-13
60-EF-12
60-EF-15
60-EF-16
60-EF-17
60-EF-3
60-EF-2
60-EF-4
60-EF-14
M-401
60-IH-1
J
C.3
60-RH-1
1 1/4" 15 PSI LPS
AND 1/2" LPC UP
FROM BELOW
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
KEY PLAN
B
A
N
SPUR #: 2015
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF
PROJECT SCOPE SHOWN. REFERENCE GI011 & GI012 - PHASING PLANS
FOR MORE INFORMATION
/3
/2
:5 :2
P
M
MECHANICAL ROOF PLAN
RDC 165 OF 229CMT
BID DOCUMENTS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
MH103
N
1/8" = 1'-0"
MECHANICAL HVAC ROOF PLAN1
GENERAL NOTES:
1. PROVIDE SEISMIC BRACING ON DUCTWORK, PIPING, AND EQUIPMENT IN ACCORDANCE WITH VA STANDARD H-18-8, AND ASCE 7 CHAPTER 13. REFER TO STRUCTURAL DRAWINGS FOR ALL APPLICABLE SEISMIC CRITERIA.
KEYNOTES
10 PROVIDE HEAT TRACING FOR FREEZE PROTECTION ON ALL NEW EXTERIOR CHILLED WATER PIPES. AMBIENT
TEMPERATURE DESIGN FOR FREEZE PROTECTION SHALL BE 7 DEGREES FAHRENHEIT.
22 PROVIDE NEW CHILLED WATER SUPPLY AND RETURN CONNECTIONS FOR TEMPORARY CHILLER.
5.5
C
F
D
H
E
K
I
G
RESIDENT ROOM
RESIDENT ROOM
STAFF LOUNGE
BATH
152A
BATH
151A
TOILET
CORRIDOR
VEST
008A
BATH
146A
RESIDENT ROOM
RESIDENT ROOM
DEN
BATH
143A
RESIDENT ROOM
RESIDENT ROOM
BATH
142A
BATH
140A
RESIDENT ROOM
RESIDENT ROOM
BATH
139A
BATH
136A
RESIDENT ROOM
RESIDENT ROOM
BATH
135A
BATH
134A
RESIDENT ROOM
RESIDENT ROOM
BATH
122A
BATH
121A
RESIDENT ROOM
BARIATRIC RESIDENT
ROOM
BATH
119A
IT ROOM
ELECTRICAL
FIRE RISER ROOM
115A
BATHING ROOM
CORRIDOR
TOILET
117A
SOILED UTILITY
CLEAN UTILITY
HOME OFFICE-1
CORRIDOR
HOUSE LAUNDRY
HOME STORAGE
MED
REC THERAPY OFFICE
ART ROOM-1
TOILET
CONF. / PRIVATE DINING
LIVING ROOM
166A
CORRIDOR
MULTIPURPOSE/
ACTIVITY ROOM-1
132-A
MULTIPURPOSE/
ACTIVITY ROOM-2
132-2
LIVING ROOM
133A
DINING
133B
KITCHEN
PANTRY
HSKPG
BATH
137A
RESIDENT ROOM
RESIDENT ROOM
BATH
138A
BATH
141A
RESIDENT ROOM
EQ STORAGE
HAC
CORRIDOR
BATH
145A
CORRIDOR
CORRIDOR
VEST
006A
60-VAV-41
60-VAV-42
60-VAV-38A60-VAV-78 60-VAV-38B
60-VAV-43
60-VAV-44
60-VAV-4560-VAV-4660-VAV-4760-VAV-4860-VAV-4960-VAV-50
60-VAV-5160-VAV-5260-VAV-5360-VAV-54
60-VAV-57
60-VAV-58
60-VAV-60
60-VAV-75
60-VAV-74
60-VAV-73
60-VAV-72
60-VAV-71
60-VAV-80
60-VAV-69
60-VAV-68
60-VAV-66
60-VAV-64
60-VAV-65
60-VAV-62
60-VAV-76 60-VAV-7760-VAV-38D
EG-1
EG-1
EG-2
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
A
87653
J
21 9
B
2.5 3.5
C.3
RG-2
RG-2
RG-2
RG-2
RG-2
1,170
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
60-UH-1
60-VAV-38C
EG-2
110EG-1
SD-3
SD-3
SD-3
SD-3
SD-3
SD-4
SD-4
SD-4
SD-3
SD-4
SD-4
SD-4
SD-4
SD-4
SD-3
SD-3
SD-3
SD-3
SD-3
SD-3
SD-3
SD-3
RG-2
SD-3
SD-4
SD-3
SD-3
RG-2
SD-4
SD-4
SD-4
SD-3
SD-3
SD-3
SD-3
SD-3
SD-3
SD-4
SD-4
SD-2
SD-3
SD-3
SD-4
SD-4
SD-3
60-VAV-37
EG-1
130RG-2
RG-2
RG-2
SD-5
85 SD-5
85 SD-5
SD-5
SD-3
SD-3
60-VAV-39
60-VAV-40
SD-1
SD-5
SD-5
RG-2
RG-2
60-FPVAV-3
RG-2
SD-2
RG-2
EG-1
RG-1
60-FPVAV-4
TRANSFER
GRILLES
RG-1
ACCESS
PANEL (TYP)
SD-3
RG-1
SD-3
SD-3
RG-2
RG-2
RG-2
RG-2
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
KEY PLAN
A
N
SPUR #: 2015
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF
PROJECT SCOPE SHOWN. REFERENCE GI011 & GI012 - PHASING PLANS
FOR MORE INFORMATION
/3
/2
:5 :3
P
M
MECHANICAL HVAC AIRFLOW PLAN -
AREA A
RDC 166 OF 229CMT
BID DOCUMENTS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
MH131
N
1/8" = 1'-0"
MECHANICAL AIRFLOW AREA A PLAN1
GENERAL NOTES:
1. PROVIDE SEISMIC BRACING ON DUCTWORK, PIPING, AND EQUIPMENT IN ACCORDANCE WITH VA STANDARD H-18-8, E12E11E9A
E8A
E13E7
EH
P
EJ
EK
E6 E8E2 E4 E5
EG
EF
EE
ED
E1 E3
EF1
E10E9
K
TOILET
176A
TOILET
184A
BATHING ROOM
HOUSE LAUNDRY
DIRECTORS OFFICE
184A
MED DIR OFFICE
EQUIP STORAGE
DEN
TEAM WORKROOM
TEAM WORKROOM
GEN STORAGE
SOILED LINEN
CLEAN LINEN
HAC
SW OFFICE
NRS LDR OFFICE
CLEAN UTILITY
SOILED UTILITY
CORRIDOR
RESIDENT ROOM
BATH
175A
ELEC
RESIDENT ROOM
BATH
173A
02 FULL
167A
02 EMPTY
167B
HOUSE OFFICE
MEDICATION
RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
BATH
156A
BATH
158A
BATH
157A
BATH
159A
BATH
161A
BATH
163A
BATH
155A
RESIDENT ROOM
RESIDENT ROOM
BATH
153A
HAC
BATH
160A
BATH
162A
RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
BATH
164A
DINING AREA
166B
KITCHEN
LIVING ROOM
166A
HSKPG
166D
PANTRY
166C
RESIDENT DINING
131N&FS KITCHEN/SERVERY
131A
H. STORAGE
MOP
131B
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-2
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
EG-1
60-VAV-8
60-VAV-7
60-VAV-5
60-VAV-6
60-VAV-460-VAV-3
60-VAV-2
60-VAV-1
60-VAV-36
60-VAV-35
60-VAV-9D
60-VAV-28
60-VAV-9C
60-VAV-27
60-VAV-26
60-VAV-25
60-VAV-24
60-VAV-9B
60-VAV-21
60-VAV-20
60-VAV-19
60-VAV-18
60-VAV-84
60-VAV-83
CLC RECEP
100A
SSTV
131C
PT/OT RECEP
100B
WAITING
CORRIDOR
VESTIBULE
001A
60-VAV-32
60-VAV-31
60-VAV-30
60-VAV-34
60-VAV-29
60-VAV-15
60-VAV-14
60-VAV-12
60-VAV-11 60-VAV-10
60-VAV-9E
NOT IN SCOPE
NOT IN SCOPE
J
EG-2
EG-3
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
RG-2
EG-1
SD-4
SD-4
SD-4
SD-6
SD-6
SD-4
SD-6
SD-4
SD-4
SD-4
SD-3
SD-2
SD-2
SD-3
SD-3
170 SD-3
SD-3
SD-3
SD-3
SD-3
SD-3
115 SD-2
SD-2
SD-3
SD-2
SD-5
SD-3
60-VAV-9A
SD-2
SD-3
SD-2
SD-3
SD-2
115SD-3
SD-2
SD-2
SD-4
SD-4
SD-4
60-VAV-13
SD-5
SD-3
SD-4
SD-4
SD-4
SD-4
SD-3
SD-3
SD-5
SD-5
60-VAV-16
EG-2
120SD-5
SD-5
115 SD-2
RG-2
RG-2
RG-2
RG-2
RG-2
SD-3
RG-2 RG-2
SD-3
SD-3
SD-2
SD-4
60-VAV-17
SD-3
EG-1
SD-4
EG-1
EG-3
SD-3
SD-3
SD-3
RG-2
60-FPVAV-2
SD-3
SD-5
SD-5
SD-3
SD-3
EG-1
RG-2
60-VAV-80
TRANSFER GRILLE
60-FPVAV-1
ACCESS
PANEL (TYP)
SD-3
RG-2
RG-2
RG-2
EI
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
KEY PLAN
B
N
SPUR #: 2015
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF
PROJECT SCOPE SHOWN. REFERENCE GI011 & GI012 - PHASING PLANS
FOR MORE INFORMATION
/3
/2
:5 :5
P
M
MECHANICAL HVAC AIRFLOW PLAN -
AREA B
RDC 167 OF 229CMT
BID DOCUMENTS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
MH132
N
1/8" = 1'-0"
MECHANICAL AIRFLOW AREA B PLAN1
GENERAL NOTES:
1. PROVIDE SEISMIC BRACING ON DUCTWORK, PIPING, AND EQUIPMENT IN ACCORDANCE WITH VA STANDARD H-18-8, C
F
D
H
E
K
I
G
6.5
MP STORAGE
132A
MULTIPURPOSE/
ACTIVITY ROOM-2
132-2
MULTIPURPOSE/
ACTIVITY ROOM-1
132-A
CONF. / PRIVATE DINING
TOILET
ART ROOM-1
REC THERAPY OFFICE
MED
HOME STORAGE
HOUSE LAUNDRY
CORRIDOR
HOME OFFICE-1
TOILET
117A
CLEAN UTILITY
SOILED UTILITY
BATHING ROOM
IT ROOM
ELECTRICAL
FIRE RISER ROOM
115A
VEST
006A
BATH
119A
BARIATRIC RESIDENT
ROOM
RESIDENT ROOM
RESIDENT ROOM
BATH
122A
BATH
121A
RESIDENT ROOM
RESIDENT ROOM
BATH
134A
BATH
135A
RESIDENT ROOM
BATH
136A
BATH
139A
RESIDENT ROOM
RESIDENT ROOM
BATH
140A
BATH
142A
RESIDENT ROOM
RESIDENT ROOM
BATH
143A
DEN
RESIDENT ROOM
RESIDENT ROOM
CORRIDOR
BATH
145A
VEST
008A
STAFF LOUNGE
RESIDENT ROOM
BATH
151A
TOILET
RESIDENT ROOM
BATH
152A
CORRIDOR
CORRIDOR
EQ STORAGE
RESIDENT ROOM
BATH
141A
BATH
138A
RESIDENT ROOM
RESIDENT ROOM
BATH
137A
HSKPG
PANTRY
KITCHEN
DINING
133B
LIVING ROOM
133A
CORRIDOR
CORRIDOR
HAC
LIVING ROOM
166A
60-VAV-54
60-VAV-53
60-VAV-58
60-VAV-57 60-VAV-60
60-VAV-75
60-VAV-74
60-VAV-73
60-VAV-6560-VAV-6460-VAV-62
60-VAV-76 60-VAV-77
60-VAV-78
60-VAV-43
60-VAV-44
60-VAV-4560-VAV-46
60-VAV-42
60-VAV-41
60-VAV-40
60-VAV-39
60-VAV-80
60-VAV-69
60-VAV-68
60-VAV-71
60-VAV-72
60-VAV-66
60-VAV-51
60-VAV-50 60-VAV-49 60-VAV-4760-VAV-48
60-VAV-52
60-VAV-38A
60-VAV-37
60-VAV-38D
60-VAV-38B
60-VAV-38C
3" HHS3" HHR
2" H
H S
2" H
H S
1/
4" H
H S
2" HHS2" HHS
1" H
H S
3/ 4"
H H
S
2" H
H R
1" H
H R
1" H
H R
1 1/4" HHS
1 1/2" HHS
1 1/2" HHR1 1/4" HHR
3/ 4"
H H
S
3/ 4"
H H
R
1/
4" H
H S
3/4" HHS
1 1/4" HHS1 1/2" HHS1 1/2" HHS1 1/2" HHS 1 1/2" HHS1 1/2" HHS1 1/2" HHS
1" H
H S
1" H
H S
1" H
H R
1 1/2" HHS
1" H
H S
1/
4" H
H R
1 1/4" HHS1 1/4" HHS
1 1/4" HHR
1" HHS
1" HHR
3/4" HHR
1 1/2" HHR
1 1/2" HHR
1 1/2" HHR 1 1/4" HHR
3/ 4"
H H
R 3/
4" H
H S
3/ 4"
H H
R
2" HHR
1 1/4" HHR1" HHR
1" HHS
1 1/4" HHS
1 1/4" HHR
3" HPC
BATH
146A
DOWN FROM
EXISTING
PENTHOUSE
A
87653
J
21 9
B
2.5 3.5
C.3
EXISTING
VAV
(TYP)
60-UH-1
3" H
H S
3" H
H R
3/ 4"
H H
R
1/ 4"
H H
R 2"
H H
R
1 1/2" HHR
REFER TO PLAN
3/MH401 FOR
CONTINUATION 2"
H H
S
1/
2" L
P S
3" H
P C
2" HHR
60-FPVAV-3
1" H
H R
60-FPVAV-4
ACCESS
PANEL (TYP)
T
VAV-52
T
VAV-51 T
VAV-50
T
VAV-49
T
VAV-48
T
VAV-47
T
VAV-46
T
VAV-45
T
VAV-77
T
VAV-78
T
VAV-74
T
VAV-76 T
VAV-43
T
VAV-44
T
VAV-42
T
FPVAV-4
T
VAV-41
T
VAV-53
T
VAV-54
T
VAV-57
T
VAV-58
T
VAV-60
T
VAV-71
T
VAV-73
T
VAV-69
T
VAV-68
T
VAV-39
T
VAV-40
T
VAV-66
T
VAV-65
T
VAV-64
T
VAV-62
T
FPVAV-3
T
VAV-72
T
VAV-38C
T
VAV-38D
T
VAV-38B
T
VAV-37
T
VAV-38A
STEAM
DISPERSION
1/
4" L
P S
1/ 2"
L P
C
1/ 2"
L P
C
1" H
H S
3/4" LPC 1/2" LPC
1 1/2" LPC
3/ 4"
L P
S
1/ 4"
L P
S
1/ 2"
L P
C
2" 15PSI LPS DOWN
FROM PENTHOUSE
1 1/4" LPS
1 1/4" LPC
M-501
1" HHR
1" HHS
3/4" HHR
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL/CIVIL
ENGINEER
H2B
1225 N. LOOP W #800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH
ENGINEER
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
LANDSCAPE ARCHITECT
CLS & ASSOCIATES
825 N. BROADWAY AVE, STE 315
OKLAHOMA, OK 73102
(405) 525-2220
HEALTHCARE/MED
EQUIPMENT PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT SECURITY
CONSULTANTS,
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
FOOD & BEVERAGE
PLANNER
STURM CONSULTING
5838 S. HUDSON PLACE
TULSA, OK 74135
(918) 260-0667
ENVIRONMENTAL
ENGINEER
RIVERFRONT ENVIRONMENTAL
1139 OLIVE STREET, STE 300
ST. LOUIS, MO 63101
(314) 436-9492
KEY PLAN
A
N
SPUR #: 2015
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF
PROJECT SCOPE SHOWN. REFERENCE GI011 & GI012 - PHASING PLANS
FOR MORE INFORMATION
/3
/2
:5 :5
P
M
MECHANICAL HVAC PIPING PLAN - AREA
A
RDC 168 OF 229CMT
BID DOCUMENTS
ADDITION AND RENOVATION
OF CLC
09/06/2023
589-703
ROBERT J. DOLE VA MEDICAL CENTER
5500 EAST KELLOGG, BLDG. 60
WICHITA, KS 67218
MP101
N
1/8" = 1'-0"
HVAC LEVEL 1 - PIPING PLAN - AREA A1
KEYNOTES
1 3" HWS & HWR UP TO PENTHOUSE FOR EXPANSION TO FUTURE SECOND LEVEL.
6 2 1/2" HPS & 3" HPC UP TO NEW PENTHOUSE.
19 DUCT AND PIPE CROSSING SEISMIC JOINT REQUIRE BELLOWS AND FLEXIBLE CONNECTIONS, REFER TO M-501 DETAILS 8
AND 15 FOR MORE INFORMATION.
GENERAL NOTES:
1. PROVIDE SEISMIC BRACING ON DUCTWORK, PIPING, AND EQUIPMENT IN ACCORDANCE WITH VA STANDARD H-18-8, AND ASCE 7 CHAPTER 13. REFER TO STRUCTURAL DRAWINGS FOR ALL APPLICABLE SEISMIC CRITERIA.
2. NEW HEATING WATER SUPPLY AND RETURN BRANCHES TO TERMINAL UNITS TO BE 3/4" UNLESS TAGGED OTHERWISE.
E12E11E9A E13E7
EH
P
EJ
EK
E6 E8E2 E4 E5
EG
EF
EE
E1 E3
EF1
E10E9
60-VAV-7
60-VAV-8
60-VAV-1060-VAV-11
60-VAV-12
60-VAV-13
60-VAV-14
60-VAV-15
60-VAV-16
60-VAV-27
60-VAV-26
60-VAV-17
60-VAV-18
60-VAV-25
60-VAV-24
60-VAV-19
60-VAV-20
60-VAV-21
60-VAV-9A
60-VAV-31
60-VAV-30
60-VAV-29
60-VAV-34
60-VAV-28
60-VAV-35
60-VAV-36
60-VAV-1
60-VAV-2
60-VAV-3 60-VAV-4 60-VAV-5
60-VAV-6
60-VAV-32
60-FPVAV-2
2" HHS
60-VAV-9B
60-VAV-9C
60-VAV-9D
60-VAV-9E
1 1/2" HHS
1" HHR
1 1/4" HHR
1 1/2" HHS
1 1/4" HHS 1 1/4" HHS
1 1/4" HHR
1 1/4" HHR
1 1/4" HHS
1 1/4" HHR
1 1/4" HHS1 1/4" HHR
1 1/2" HHR1" HHS1" HHS1 1/2" HHR1" HHS
1 1/2" HHR1 1/2" HHR
1" HHS
1" HHS
1 1/2" HHR
3/4" HHS
1 1/2" HHR
2" HHR 3/4" HHS
2" HHR
1" HHS
2" HHS
1 1/2" HHS
1 1/4" HHR
1 1/2" HHS
1 1/4" HHR
1 1/2" HHS
1 1/4" HHS
1 1/4" HHR
1 1/2" HHR
1" HHS
1" HHS
1 1/2" HHR
2" HHR
2" HHR
3/4" HHS
2" HHR
1" HHS 1" HHR
1" HHS
1" HHR
1" HHS1" HHR
2" HHS
2" HHS
1 1/2" HHS
2" HHR
2" HHS
2" HHR
1" HHS
1" HHR
1" HHS
3/4" HHS
3/4" HHS
1" HHS 1" HHR
1" HHS
1" HHR
1" HHR
1 1/2" HHS
1" HHS
2" HHR
2" HHR
1 1/2" HHS
1 1/4" HHS
1 1/2" HHR
3/4" HHR3/4" HHR
1" HHR
1" HHR
1" HHS
1" HHS
3/4" HHS
1" HHR
TOILET
176A
TOILET
184A
BATHING ROOM
HOUSE LAUNDRY
DIRECTORS OFFICE
184A
MED DIR OFFICE
EQUIP STORAGE
DEN
TEAM WORKROOM
TEAM WORKROOM
GEN STORAGE
SOILED LINEN
CLEAN LINEN
HAC
SW OFFICE
NRS LDR OFFICE
CLEAN UTILITY
SOILED UTILITY
CORRIDOR
RESIDENT ROOM
BATH
175A
ELEC
RESIDENT ROOM
BATH
173A
02 FULL
167A
02 EMPTY
167B
HOUSE OFFICE
MEDICATION
RESIDENT ROOM
RESIDENT ROOM
161 RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
BATH
156A
BATH
158A
BATH
157A
BATH
159A
BATH
161A
BATH
163A
BATH
155A
RESIDENT ROOM
RESIDENT ROOM
BATH
153A
HAC
BATH
160A
BATH
162A
RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
BATH
164A
DINING AREA
166B
KITCHEN
LIVING ROOM
166A
HSKPG
166D
PANTRY
166C
RESIDENT DINING
N&FS KITCHEN/SERVERY
131A
H. STORAGE
HAC
131B
2" HHS 2" HHS
3/4" HHR
3/4" HHS
3/4" HHS
3/4" HHR
3/4" HHR
3/4" HHS
3/4" HHR
60-VAV-84
60-VAV-83
NOT IN SCOPE
NOT IN SCOPE
3/ 4"
H H
R 3/ 4"
H H
S
1" HHR
60-FPVAV-1
ACCESS
PANEL (TYP)
T
VAV-4
T
VAV-5
T
VAV-6
T
VAV-3
T
VAV-2
T
VAV-1
T
VAV-12
T
VAV-11
T
VAV-10
T
VAV-8
T
VAV-7
T
VAV-32
T
VAV-34
T
VAV-21
T
VAV-20
T
VAV-19
T
VAV-18
T
VAV-17
T
VAV-26
T
VAV-27
T
VAV-25
T
VAV-14
T
VAV-31
T
VAV-30
T
VAV-29
T
VAV-28
T
VAV-36
T
VAV-35
T
VAV-15
T
VAV-15
T
VAV-13
T
VAV-14
T
FPVAV-2
T
VAV-84
T
VAV-83
T
FPVAV-1
T
VAV-9B
T
VAV-9C
T
VAV-9E
T
VAV-9D
1" HHS
1" HHR
1 1/4" HHR
1 1/2" HHS
1" HHS
1" HHR
1" HHR
1" HHR
1/2" LPC
1 1/4" LPS1/2" LPC AND
1 1/4" 15PSI LPS
UP TO MUA-1
M-501
8' - 4 9/32"
EI
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .