Develop Airmen…Forge Aviators…Deploy Warriors
JBSA Randolph AFB, TX Location Map
HANGAR
HANGAR 12
MAIN GATE
HANGAR 13
HANGAR 6
HANGAR 12: DESIGN DOCUMENTS
Hangar 12 Renovation
=2.5 Flight CC Office
=A Flight CC Office
=DOV Chief Office
=2.5 Flight Room
=2.5 ITD Room
=C Flight CC Office
ITD/Flight Room Demo Work
All dimensions are approximate.
ITD
Desk
ITD
ITD
ITD
36.75 ft10.6 ft9.83 ft
24 ft
Room 10 Room 9 Room 8
Demo Work:
• One wall removed ~ 24 LF
• Remove and dispose of carpet in Rooms 8, 9, and 10.
• Modular furniture per CLIN Options in Room 8, 9, and 10.
• Remove door frames and doors from Room 10 and set aside for reuse.
• Remove ceiling grid and tiles and Room 9 & 10 during demolition of wall x x x
72 x 36 61 x 24
69 x 28
47x23 33x16
Room 8
54 x 30 48x23
54 x 30
48x23
54 x 30 48x23
60 x 24
60 x 24
60 x 24
60 x 24
60 x 30 60 x 30 60 x 30 60 x 30
84 x 24 Desks
60 x 30
36 x
60 x 24
50x18
83 x 36 Table
49 x 25 80 x 32 C ouch
ITD/Flight Room New Work
ITD
DeskDesk
L- Shape Desk/ Chairs
L- Shape Desk/ Chairs
L- Shape Desk/ Chairs
L- Shape Desk/ Chairs
L- Shape Desk/ Chairs
L- Shape Desk/ Chairs
L- Sh ap e D es k/
C ha irs
L- Sh ap e D es k/
C ha irs
Study Table with 10xchairs
Desk/chair w/1 AFNET computer
Desk w/2 AFNET computers & 2 Chairs
New Work:
• Install visual fire alarms to ITD room, per NFPA requirements.
• Install power breakers to ITD room. Install new A/C to ITD room. Install 6 light fixtures to one switch. Install electrical outlets to support ITD’s.
• Reinstall ceiling grid with necessary supports and reinstall ceiling tiles. Reinstall heat device and WiFi.
• Add data/ comm and telephone on sidewalls at new desk. Provide testing on data and comm. Install additional data/ comm next to electrical boxes for each ITD.
• Install new carpet in both rooms and new furniture. Install blockings to support TV’s and whiteboards.
• Repair walls as needed with gypsum board where electrical work was done. Paint using 1 coat primer and 2 coats of paint on all repair work.
• Fill three doors and add base cove. Install door frame, door and door doorstop. Contractor to reuse doorframe and door from demolished door.
• Provide new standalone HVAC to support trainer equipment in room.
• Reinstall supply and return air vents. Provide test and balance on HVAC.
= 32” TV
= Whiteboard
= 85” TV
ITD
ITD
ITD
ITD
ITD
ITD
ITD
FLIGHT ROOM
ITD ROOM
Flight CC Office Demo Work
Demo Work
• Remove, all modular furniture, as shown in picture above.
• Remove handrail in main hallway.
Room 4
All dimensions are approximate.
Existing modular furniture
New Work
New Work
• Add new door frame, door, and doorstop into hallway. Contractor to reuse doorframe and door from demolished door.
• Repair carpet around door work with attic over stock. NOTE: Entire room will not get new carpet – only area around door frame work.
• Paint using 1 coat primer and 2 coats of paint on all repair work.
Room 4
A Flight CC Office Demo Work
Demo Work:
• Remove door frame and door.
• Remove existing light switch.
• Remove furniture per CLIN Options in Room x
Room 14
Desk/chair w/1 AFNET computer
D esk/chair w
/1
AFN
ET com puter
A Flight CC Office New Work
New Work:
• Fill east door opening and add base cove.
• Add door frame and door. Contractor to reuse doorframe and door from demolished door.
• Repair carpet around door work with attic over stock. NOTE:
Entire room will not get new carpet – only area around door frame work.
• Add new west door.
• Add electrical outlets to walls shown. Install new light switch.
• Paint using 1 coat primer and 2 coats of paint on all repair work.
• Install new conduit for data and phone on west wall.
x
Room 14
Desk/chair w/1 AFNET computer
D esk/chair w
/1
AFN
ET com
DOV Chief Office Demo Work
Demo Work:
• Remove Modular furniture per CLIN Options in Room
• Remove carpet for installation of wall bottom plate. Not all carpet should be removed – only enough to install plate.
• Demolish ceiling grid and tiles.
• Cut ceiling grid for installation of new metal studs for wall opening.
Room 16
D esk/chair w
/1
AFN
ET com
Furniture removed/demolished:
Room 16
OPR: ALF CAO: 18 Dec 20
DOV Chief Office New Work
New Work:
• Add north door
• Add electrical light switch
• Install new divider wall – 12-ft x 8-ft. with cross bracing.
• Reinstall ceiling grid with necessary supports
• Reinstall ceiling tiles.
• Cut new door opening. Contractor to reuse doorframe and door from demolished door.
• Install new heat device on ceiling grid.
• Install new return air vent for room.
Room 16
D esk/chair w
/1
AFN
ET com
Demo Work
Demo Work:
• Modular furniture per CLIN Options in Room
• Remove ceiling grid and tile from middle of room (~ 11.5-ft)
• Remove a portion of carpet for construction of new divider wall that will split room.
• Split electrical wiring to support light fixtures for two office areas.
• Split ductwork for additional return vent.
Room 18
Desk/chair w/1 AFNET computer
D esk/chair w
/1
AFN
ET com puter
Desk/chair w/1 AFNET computer
D esk/chair w /1
AFN
ET
com
New Work
New Work:
• Construct new divider wall to split office into two offices.
• Reinstall ceiling grid with necessary supports.
• Reinstall ceiling tiles
• Paint using 1 coat primer and 2 coats of paint on all new work.
• Newly created Room 18 receives new carpet.
Replace portions of carpet around new wall on closed off office with attic stock. NOTE: Entire room will not get new carpet – only area around work from wall.
• Install new light switch by new door.
• Install additional heat device on ceiling grid.
• Install new electrical conduit with boxes for electrical outlets and data on new wall.
Room 18
All dimensions are approximate.
47x22 69 x 28
48 x 30 Case
72 x 36
60 x 24
HANGAR 64: DESIGN DOCUMENTS
Hangar 64 - Add Washer/ Dryer Demo Work
Demo Work:
• Remove existing shower head.
• Remove existing shower tile front walls/doors to entrance of stall. Remove existing shower tile front walls/doors to entrance of stall
– 12- inches each side
Hangar 64 - Add Washer/ Dryer New Work
New Work:
• Add ventilation
• Extend water line connection
New Washer/ Dryer area
JBSA Vision: The Premier Installation in the Department of Defense!
One Team, One Mission
HVAC Zones – Hangar 12
1401561150C Rectangle
1401561150C Rectangle
1401561150C Rectangle
1401561150C Rectangle
1401561150C Typewritten Text
ZONE 1
1401561150C Typewritten Text
ZONE 2
1401561150C Typewritten Text
ZONE 3
1401561150C Typewritten Text
ZONE 4
1401561150C Rectangle
1401561150C Rectangle
1401561150C Rectangle
1401561150C Rectangle
1401561150C Typewritten Text
IMMERSIVE TRAINING DEVICE:
SPECIFICATION SHEET
WITH MOTION
71.5
.2
WITHOUT MOTION
65.0
8.
.0
A
.0
6.
35.1
34.8 21.2
APPROXIMATE DEPTH OF 4U
DETAIL A
SCALE 1 : 10
INCHES
SIGNATURE: DATE:
QA:
MFG:
APPV'D:
DRAWN:
DIMENSIONS ARE IN MM
Sizing Specifications - Immersive Training Device (ITD)
CHRIS RYAN
A4
SHEET 1 OF 1
SCALE: 1:20
COPYRIGHT © RYAN AEROSPACE. CONFIDENTIAL INFORMATION
CONTAINED WITHIN
CHRIS RYAN
NOT YET SPECIFIED kg
0MASS:
FILE NAME:
CONFIG:
PART #:
MATERIAL: AS PER BOM
REVISION:
Weight – 240 lbs Electrics – 120v, the “lower end” ITD’s average 4.5A RMS; the higher end w/motion average 5A RMS. Power in Watts = RMS Volts (V) x RMS Amps (A) x Power Factor.
PF of 1 HEAT LOAD = 600 W or 2,047.3 BTU/hr.
ASBESTOS REPORT: HANGAR 64
PLM Summary Report
Client :
Project :
Project # :
Identification :
Test Method :
JBSA Randolph - 802 CES / CEIE
Hanger 64 Lean-to Renovation
Not Provided
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 3/7/2019, twenty seven (27) bulk material samples were submitted by Edward Vogel of JBSA Randolph - 802 CES / CEIE for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
19B-02617
03/05/2019
03/11/2019
NVLAP Lab Code 102056-0
TDSHS License No. 30-0084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
64-WLSH-001-
Sheetrock, Lean-to, ADO None Detected - Drywall Material
None Detected - Paint
64-WLSH-001-
Sheetrock, Lean-to, Training Office None Detected - Drywall Material
None Detected - Texture
64-WLSH-001-
Sheetrock, Lean-to, CAP None Detected - Drywall Material
None Detected - Paint
64-WLSH-001-
Sheetrock, Lean-to, Msn Planning None Detected - Drywall Material
None Detected - Texture / Joint Cmpd
64-WLSH-001-
Sheetrock, Lean-to, Men's Restroom None Detected - Drywall Material
None Detected - Texture
64-WLSH-001-
Sheetrock, Lean-to, Northwest Hallway None Detected - Drywall Material
64-WLSH-001-
Sheetrock, Lean-to, Northwest Hallway Ceiling None Detected - Drywall Material
64-WLTX-001-
Wall Texture, Lean-to, Training Office None Detected - Texture
64-WLTX-001-
Wall Texture, Lean-to, Northwest Hallway None Detected - Drywall Material
None Detected - Texture
64-WLTX-001-
Wall Texture, Lean-to, Smokin Hole None Detected - Texture
64-WLJ-001-011 Float Mud / Joint Compound, Lean-to, Smokin Hole None Detected - Joint Compound
64-WLJ-001-012 Float Mud / Joint Compound, Lean-to, CAP None Detected - Joint Compound
64-WLJ-001-013 Float Mud / Joint Compound, Lean-to, Msn Planning None Detected - Joint Compound
None Detected - Caulking
64-CLLI-001-014 Ceiling Tile, Lean-to, Msn Planning None Detected - Acoustic Tile
64-CLLI-001-015 Ceiling Tile, Lean-to, ADO None Detected - Acoustic Tile
64-CLLI-001-016 Ceiling Tile, Lean-to, Smokin Hole None Detected - Acoustic Tile
Project :
Project # :
Identification :
Test Method :
JBSA Randolph - 802 CES / CEIE
Hanger 64 Lean-to Renovation
Not Provided
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 3/7/2019, twenty seven (27) bulk material samples were submitted by Edward Vogel of JBSA Randolph - 802 CES / CEIE for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
19B-02617
03/05/2019
03/11/2019
NVLAP Lab Code 102056-0
TDSHS License No. 30-0084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
64-CLLI-001-017 None Detected - Acoustic Tile
64-FLC-001-018 None Detected - Off-White Mastic
None Detected - Leveling Compound
64-FLC-001-019 None Detected - Off-White Mastic
None Detected - Leveling Compound
64-FLC-001-020 None Detected - Off-White Mastic
None Detected - Leveling Compound
64-FLVCT-001-
None Detected - Black Floor Tile
None Detected - Yellow Mastic
None Detected - White Floor Tile
None Detected - Yellow Mastic
64-FLVCT-001-
None Detected - Gray Floor Tile
None Detected - Yellow Mastic
64-CJC-001-023 2% Chrysotile - Joint Compound
64-CJC-001-024 2% Chrysotile - Joint Compound
64-CBM-001-025 None Detected - Cream Mastic
None Detected - Yellow Mastic
64-CLSH-001-
None Detected - Drywall Material
64-PINS-001-027
Ceiling Tile, Lean-to, Restroom Hallway
Floor Level Compound, Lean-to, Msn Planning 1
Floor Level Compound, Lean-to, Msn Planning 2
Floor Level Compound, Lean-to, Msn Planning 3
12" x 12" Floor Tile (Black and White Checker), Lean-to, Northwest Hallway
12" x 12" Floor Tile (Gray), Lean-to, Smokin Hole
Ceiling Joint Compound, Lean-to, Smokin Hole
Ceiling Joint Compound, Lean-to, Northwest Hallway
Cove Base Mastic, Lean-to, Smokin Hole
Ceiling Sheetrock, Lean-to, Smokin Hole
Pipe Insulation, Lean-to, Northwest Hallway 20% Chrysotile - Thermal Insulation
None Detected - Cotton Wrap
Project :
Project # :
Identification :
Test Method :
JBSA Randolph - 802 CES / CEIE
Hanger 64 Lean-to Renovation
Not Provided
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 3/7/2019, twenty seven (27) bulk material samples were submitted by Edward Vogel of JBSA Randolph - 802 CES / CEIE for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
19B-02617
03/05/2019
03/11/2019
NVLAP Lab Code 102056-0
TDSHS License No. 30-0084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
Debra O'Sullivan, Jessica ScottAnalyst(s):
Lab Director : Bruce Crabb Approved Signatory :
Thank you for choosing Moody Labs
Lab Manager : Heather Lopez Approved Signatory :
These samples were analyzed by layers. Quantification, unless otherwise noted, is performed by calibrated visual estimate. The test report shall not be reproduced, except in full, without written approval of the laboratory. The results relate only to the items tested. These test results do not imply endorsement by NVLAP or any agency of the U.S.
Government. Accredited by the National Voluntary Laboratory Accreditation Program for Bulk Asbestos Fiber Analysis under Lab Code 102056-0.
This Page Left Intentionally Blank
PLM Detail Report
Project # : Not Provided
Sample Number Layer Components % Of
Sample
Analysis
Date
% of
Layer Analyst
Supplement to PLM Summary Report
Client :
Project :
JBSA Randolph - 802 CES / CEIE
Hanger 64 Lean-to Renovation
Lab Job No. :
Report Date :
19B-02617
03/11/2019
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
Moody Labs NVLAP Lab Code 102056-0
TDSHS License No. 30-0084
Glass Wool Fibers64-WLSH-001-
Drywall Material (White) 65% 03/082% JS
Cellulose Fibers64-WLSH-001-
Drywall Material (White) 65% 03/081% JS
Gypsum / Binders64-WLSH-001-
Drywall Material (White) 65% 03/0897% JS
Cellulose Fibers64-WLSH-001-
DW Paper Facing (Tan) 35% 03/08100% JS
Pigment / Binders64-WLSH-001-
Paint (Tan) <1% 03/08100% JS
Glass Wool Fibers64-WLSH-001-
Drywall Material (White) 90% 03/082% JS
Cellulose Fibers64-WLSH-001-
Drywall Material (White) 90% 03/081% JS
Gypsum / Binders64-WLSH-001-
Drywall Material (White) 90% 03/0897% JS
Cellulose Fibers64-WLSH-001-
DW Paper Facing (Tan) 10% 03/08100% JS
Calcite / Talc / Binders64-WLSH-001-
Texture (White) <1% 03/08100% JS
Glass Wool Fibers64-WLSH-001-
Drywall Material (White) 93% 03/082% JS
Cellulose Fibers64-WLSH-001-
Drywall Material (White) 93% 03/081% JS
Gypsum / Binders64-WLSH-001-
Drywall Material (White) 93% 03/0897% JS
Cellulose Fibers64-WLSH-001-
DW Paper Facing (Tan) 2% 03/08100% JS
Pigment / Binders64-WLSH-001-
Paint (Light Blue) 5% 03/08100% JS
Cellulose Fibers64-WLSH-001-
Drywall Material (White) 10% 03/085% JS
Gypsum / Binders64-WLSH-001-
Drywall Material (White) 10% 03/0895% JS
Calcite / Talc / Binders64-WLSH-001-
Texture / Joint Cmpd (White) 90% 03/08100% JS
Sample Number Layer Components % Of
Sample
Analysis
Date
% of
Layer Analyst
Supplement to PLM Summary Report
Client :
Project :
JBSA Randolph - 802 CES / CEIE
Hanger 64 Lean-to Renovation
Lab Job No. :
Report Date :
19B-02617
03/11/2019
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
Moody Labs NVLAP Lab Code 102056-0
TDSHS License No. 30-0084
Glass Wool Fibers64-WLSH-001-
Drywall Material (White) 88% 03/082% JS
Cellulose Fibers64-WLSH-001-
Drywall Material (White) 88% 03/081% JS
Gypsum / Binders64-WLSH-001-
Drywall Material (White) 88% 03/0897% JS
Cellulose Fibers64-WLSH-001-
DW Paper Facing (Tan) 10% 03/08100% JS
Calcite / Talc / Binders64-WLSH-001-
Texture (White) 2% 03/08100% JS
Glass Wool Fibers64-WLSH-001-
Drywall Material (White) 90% 03/082% JS
Cellulose Fibers64-WLSH-001-
Drywall Material (White) 90% 03/081% JS
Gypsum / Binders64-WLSH-001-
Drywall Material (White) 90% 03/0897% JS
Cellulose Fibers64-WLSH-001-
DW Paper Facing (Tan) 10% 03/08100% JS
Cellulose Fibers64-WLSH-001-
Drywall Material (White) 95% 03/085% JS
Gypsum / Binders64-WLSH-001-
Drywall Material (White) 95% 03/0895% JS
Cellulose Fibers64-WLSH-001-
DW Paper Facing (Tan) 5% 03/08100% JS
Calcite / Talc / Binders64-WLTX-001-
Texture (White) 100% 03/09100% DO
Glass Wool Fibers64-WLTX-001-
Drywall Material (White) 45% 03/092% DO
Cellulose Fibers64-WLTX-001-
Drywall Material (White) 45% 03/091% DO
Gypsum / Binders64-WLTX-001-
Drywall Material (White) 45% 03/0997% DO
Cellulose Fibers64-WLTX-001-
DW Paper Facing (Tan) 10% 03/09100% DO
Calcite / Talc / Binders64-WLTX-001-
Texture (White) 45% 03/09100% DO
Sample Number Layer Components % Of
Sample
Analysis
Date
% of
Layer Analyst
Supplement to PLM Summary Report
Client :
Project :
JBSA Randolph - 802 CES / CEIE
Hanger 64 Lean-to Renovation
Lab Job No. :
Report Date :
19B-02617
03/11/2019
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
Moody Labs NVLAP Lab Code 102056-0
TDSHS License No. 30-0084
Calcite / Talc / Binders64-WLTX-001-
Texture (White) 100% 03/09100% DO
Calcite / Talc / Binders64-WLJ-001-011 Joint Compound (White) 100% 03/09100% DO
Calcite / Talc / Binders64-WLJ-001-012 Joint Compound (White) 100% 03/09100% DO
Calcite / Talc / Binders64-WLJ-001-013 Joint Compound (White) 45% 03/09100% DO
Calcite64-WLJ-001-013 Caulking (White) 55% 03/0950% DO
Binders / Fillers64-WLJ-001-013 Caulking (White) 55% 03/0950% DO
Cellulose Fibers64-CLLI-001-014 Acoustic Tile (Light Tan) 100% 03/0980% DO
Perlite64-CLLI-001-014 Acoustic Tile (Light Tan) 100% 03/0920% DO
Cellulose Fibers64-CLLI-001-015 Acoustic Tile (Light Grey) 100% 03/0950% DO
Mineral Wool Fibers64-CLLI-001-015 Acoustic Tile (Light Grey) 100% 03/0930% DO
Perlite64-CLLI-001-015 Acoustic Tile (Light Grey) 100% 03/0920% DO
Cellulose Fibers64-CLLI-001-016 Acoustic Tile (Light Grey) 100% 03/0950% DO
Mineral Wool Fibers64-CLLI-001-016 Acoustic Tile (Light Grey) 100% 03/0930% DO
Perlite64-CLLI-001-016 Acoustic Tile (Light Grey) 100% 03/0920% DO
Cellulose Fibers64-CLLI-001-017 Acoustic Tile (Light Grey) 100% 03/0950% DO
Mineral Wool Fibers64-CLLI-001-017 Acoustic Tile (Light Grey) 100% 03/0930% DO
Perlite64-CLLI-001-017 Acoustic Tile (Light Grey) 100% 03/0920% DO
Glue Binders64-FLC-001-018 Off-White Mastic (Off-White) 1% 03/09100% DO
Cellulose Fibers64-FLC-001-018 Leveling Compound (Gray) 99% 03/095% DO
Calcite / Binders64-FLC-001-018 Leveling Compound (Gray) 99% 03/0995% DO
Glue Binders64-FLC-001-019 Off-White Mastic (Off-White) 1% 03/09100% DO
Cellulose Fibers64-FLC-001-019 Leveling Compound (Gray) 99% 03/095% DO
Calcite / Binders64-FLC-001-019 Leveling Compound (Gray) 99% 03/0995% DO
Glue Binders64-FLC-001-020 Off-White Mastic (Off-White) 1% 03/09100% DO
Cellulose Fibers64-FLC-001-020 Leveling Compound (Gray) 99% 03/095% DO
Calcite / Binders64-FLC-001-020 Leveling Compound (Gray) 99% 03/0995% DO
Sample Number Layer Components % Of
Sample
Analysis
Date
% of
Layer Analyst
Supplement to PLM Summary Report
Client :
Project :
JBSA Randolph - 802 CES / CEIE
Hanger 64 Lean-to Renovation
Lab Job No. :
Report Date :
19B-02617
03/11/2019
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
Moody Labs NVLAP Lab Code 102056-0
TDSHS License No. 30-0084
Calcite / Vinyl Binders64-FLVCT-001-
Black Floor Tile (Black) 50% 03/09100% DO
Calcite64-FLVCT-001-
Yellow Mastic (Yellow) 1% 03/0940% DO
Glue Binders64-FLVCT-001-
Yellow Mastic (Yellow) 1% 03/0960% DO
Calcite / Vinyl Binders64-FLVCT-001-
White Floor Tile (White) 49% 03/09100% DO
Calcite64-FLVCT-001-
Yellow Mastic (Yellow) <1% 03/0940% DO
Glue Binders64-FLVCT-001-
Yellow Mastic (Yellow) <1% 03/0960% DO
Calcite / Vinyl Binders64-FLVCT-001-
Gray Floor Tile (Gray) 99% 03/09100% DO
Calcite64-FLVCT-001-
Yellow Mastic (Yellow) 1% 03/0940% DO
Glue Binders64-FLVCT-001-
Yellow Mastic (Yellow) 1% 03/0960% DO
Cellulose Fibers64-CJC-001-023 DW Paper Facing (Tan) 25% 03/09100% DO
Chrysotile64-CJC-001-023 Joint Compound (White) 75% 03/092% DO
Calcite / Talc / Binders64-CJC-001-023 Joint Compound (White) 75% 03/0998% DO
Chrysotile64-CJC-001-024 Joint Compound (White) 100% 03/092% DO
Calcite / Talc / Binders64-CJC-001-024 Joint Compound (White) 100% 03/0998% DO
Note: No Ceiling Tile
Calcite64-CBM-001-025 Cream Mastic (Cream) 90% 03/0950% DO
Glue Binders64-CBM-001-025 Cream Mastic (Cream) 90% 03/0950% DO
Glue Binders64-CBM-001-025 Yellow Mastic (Yellow) 10% 03/09100% DO
Cellulose Fibers64-CLSH-001-026 Drywall Material (White) 95% 03/095% DO
Gypsum / Binders64-CLSH-001-026 Drywall Material (White) 95% 03/0995% DO
Cellulose Fibers64-CLSH-001-026 DW Paper Facing (Tan) 5% 03/09100% DO
Chrysotile64-PINS-001-027 Thermal Insulation (White) 85% 03/0920% DO
Binders / Fillers64-PINS-001-027 Thermal Insulation (White) 85% 03/0980% DO
Cotton Fibers64-PINS-001-027 Cotton Wrap (Off-White) 15% 03/09100% DO
JBSA Asbestos Inventory Print Report
Facility Type:
Facility Site: JBSA Randolph
Administrative
Square Footage: 87507Number of Floors: 3
B64.tifDrawing File Name:
Facility Status: Manned
64.jpgPhoto File Name
Date Constructed: 1931
Facility Number: Facility Name:64 FLY TNG CLASSROOM
Facility Owner: 12 CES/CE
Facility Address: 171211 FLY TNG CLASSROOM Asbestos:
Facility Summary Report:
All floor tiles and mastics have been abated throughout the hangar.
04/24/2013 - Assess areas for Entomology - All areas are NAD (No Asbestos detected)
03/13/2013 - Workorder 11012- Replace Carpet through out hangar areas - The following areas are Positive for Asbestos Containing Materials. All Hallways, B Flight Chiefs Office, Survival Equipment Shop Flo and NW Exit, Mission Planning, Ados Aoffice SW End and Ados Office next to Auditorium , See Color Coded floor plan floor plan. All other Non-Asbestos Areas are also identified on the color coded floor plan. One Positive results over rides any negatives or None Detects. Do not disturb any areas that are positive for asbestos containing materials. Under the AHERA rules, we are required to take 3 samples of the same materials.
One positive result over writes any other negative results. Do not disturb by sanding drilling, nailing, scraping cutting, sanding blasting or any other operation that may disturb the positive ACM. This work must be done by a certified asbestos abatement team.
02/19/2013 - Inspect Equipment Room for Asbestos Containing Materials - All Floor tiles and mastic, Sheetrock and Joint Compound is NAD, No Asbestos Detected
11/7/2011 - Inspect Pipe materials for Mr. Kevin Meyers project - All suspect materials are NAD (No Asbestos Detected)
10/31/2011 - Repair leaking drain in restroom foyer area - All floor tiles and mastic in Restroom Foyer area NW side of hangar are NAD, (No Asbestos Detected)
06/20/2011 - Workorder 10358, Install Eye Wash Station in Life Support Section.. All floor tiles and mastic are Positive for Asbestos Containing Materials. All drywall in this area is None Detect for Asbestos Containing Materials.
04/27/2011 - workorder 10268, Relocate and position projectors. Floor tiles and Drywall resulted in NAD (No asbestos Detected)
12 May 10, 2GWLAN ProjectArea of penetration is NAD for Asbestos
01/31/2013 - Abatement of floor tiles and mastics from all Hallways, Room 21-26, ViewFacility Comments:
Facility Comments:
Date User Comment
5/20/2019 elv Request for energy and Ameresco contractors for potential areas of asbestos disturbance. This facility contains asbestos pipe insulation above the ceiling in the leanto area. All other pipes are fiberglass insulation. Ceiling Joint compound is positive for Asbestos Containing Materials on the sheetrock above the dropped ceiling grid. Some floor tiles and mastic may still remain.
Do not disturb any of these materials. Any materials not found in this report are considered suspect materials. These materials must be sampled or assumed Positive for Asbestos containing Materials. Lab analysis reports are available if needed.
4/24/2019 elv Work Order 13798 Assess areas for installation of outlets. All Sheetrock, Float Mud, Joint compounds are NAD, No Asbestos Detected.
3/18/2019 elv Assess all areas in Lean-To for Asbestos Containing Materials.
Pipe insulation above the ceiling tiles in the Northwest Halls, All Ceiling Joint Comppounds throughout are Positive for Asbestos Containing Materials. Any disturbance of these materials must be done by a certified Asbestos Abatement team. Any materials that are hidden behind walls, mirrors etc., could not be assessed and must be assumed positive for Asbestos Containing Materials or analyzed by a DSHS approved Asbestos Laboratory.
7/30/2018 elv Work Order Toxics - 13572- Install Public Address System and replace HVAC System. All areas and materials that could potentially be disturbed in this facility are NAD, No Asbestos Detected. This includes sheetrock, float Mud and Joint Compound throughout facility. All HVAC return and supply lines are fiberglass throughout. Some asbestos floor tiles and mastics still remain, hjowever these materials should not be disturbed during this project.
7/23/2018 elv Work Order 13413 - Assess for expansion and renovation project.
The heritage room, East Restrooms, training room, and West restrooms sheetrock, Float Mud/Joint Compounds are all NAD, No Asbestos Detected. The floor tile in the closet of the heritage room is NAD, No Asbestos Detected. If the floor covering in the heritage room contains floor tile underneath, then this material must be sampled prior to any disturbance.
7/1/2018 elv request for Asbestos Containing Materials for a WIFI project. The only materials that have been found to contain Asbestos Containing Materials througout this facility is floor tiles and mastics.The majority of the floor tiles and mastics have been abaed but floor tiles and mastics still remain in the ADO office.
10/16/2017 elv U3832 - Workers concern for suspect asbestos materials when changing out ceiling tiles. Acoustic Glued on Ceiling tiles are dropping from the attic ceiling onto the ceiling gridded tiles. All ceiling tiles in the grid, attached to the ceiling in the attic and the ceiling mastic in the attic are all NAD, No Asbestos Detected.
2/28/2017 elv Work Order 12108 - Relocate Doors. All sheetrok and float Mud/Joint Compound is NAD, NO Asbestos Detected in Scheduling and the training room.
10/26/2015 elv Work Order 12137 - The Statement of Work for indicates that this will be a major renovation -project. Our asbestos surveys do not include any exterior materials for Hangar 64. Any disturbance of
Asbestos Containing Material (ACM) Results Dimension
AsbestosHSA DescriptionHSA Type Sample # Year ID Location(s) Floor Floor Area
Sample Area Original Sample IDSample ID
0NAD; Fiberglass 2%; Cellulose 1%, Gypsum 97%
2019 1
Off White;Chalky;Gran; Brown FibrousWall - Sheetrock 1 SF
Lean Too 01 SF64-WLSH-001-B-001 ADO
0NAD; Fiberglass 2%; Cellulose 1%, Gypsum 97%
2019 1
Off White;Chalky;Gran; Brown FibrousWall - Sheetrock 2 SF
Lean Too 01 SF64-WLSH-001-B-002 Trng Office
0NAD; Fiberglass 2%; Cellulose 1%, Gypsum 97%
2019 1
Off White;Chalky;Gran; Brown FibrousWall - Sheetrock 3 SF
Lean Too 01 SF64-WLSH-001-B-003 CAP
0NAD; Cellulose 5%, Gypsum 95%
2019 1
Off White;Chalky;Gran; Brown FibrousWall - Sheetrock 4 SF
Lean Too 01 SF64-WLSH-001-B-004 Msn Planning
0NAD; Fiberglass 2%; Cellulose 1%, Gypsum 97%
2019 1
Off White;Chalky;Gran; Brown FibrousWall - Sheetrock 5 SF
Lean Too 01 SF64-WLSH-001-B-005 Mens RR
0NAD; Fiberglass 2%; Cellulose 1%, Gypsum 97%
2019 1
Off White;Chalky;Gran; Brown FibrousWall - Sheetrock 6 SF
Lean Too 01 SF64-WLSH-001-B-006 NW Hallway
0NAD; Cellulose 5%, Gypsum 95%
2019 1
Off White;Chalky;Gran; Brown FibrousWall - Sheetrock 7 SF
Lean Too 01 SF64-WLSH-001-B-007 NW Hallway Ceiling
0NAD; Calcite 100%
2019 1
Off White; Chalky; GranWall - Textured Surfacing Material 8 SF
Lean Too 01 SF64-WLTX-001-B-008 Trng Office
0NAD; Fiberglass 2%; Cellulose 1%, Gypsum 97%
2019 1
Off White; Chalky; Gran; Brown FibrousWall - Textured Surfacing Material 9 SF
Lean Too 01 SF64-WLTX-001-B-009 NW Hallway
0NAD; Calcite 100%
2019 1
Off White; Chalky; Gran; Brown FibrousWall - Textured Surfacing Material 10 SF
Lean Too 01 SF64-WLTX-001-B-0010 Smokin Hole
0NAD; Calcite 100%
2019 1
Off White; Chalky; Gran; Brown FibrousWall - Joint Tape/Joint Compoud 11 SF
Lean Too 01 SF64-WLJ-001-B-0011 Smokin Hole
0NAD; Calcite 100%
2019 1
Off White; Chalky; Gran; Brown FibrousWall - Joint Tape/Joint Compoud 12 SF
Lean Too 01 SF64-WLJ-001-B-0012 CAP
0NAD; Calcite 50%, Non-fibrous 50%
2019 1
Off White; Chalky; Gran; Brown FibrousWall - Joint Tape/Joint Compoud 13 SF
Lean Too 01 SF64-WLJ-001-B-0013 Msn Planning
0NAD; Calcite 100%
2019 1
Off White; Chalky; Gran; Brown FibrousWall - Joint Tape/Joint Compoud 13 SF
Lean Too 01 SF64-WLJ-001-B-0013 Msn Planning
0NAD; Cellulose 80%, Perlite 20%
2019 1
White and Brown fibrous.Ceiling - Lay-in Tile 14 SF
Lean Too 01 SF64-CLLI-001-B-0014 Msn Planning
0NAD; Fibrous 80%, Perlite 20%
2019 1
White and Brown fibrous.Ceiling - Lay-in Tile 15 SF
Lean Too 01 SF64-CLLI-001-B-0015 ADO
0NAD; Fibrous 80%, Perlite 20%
2019 1
White and Brown fibrous.Ceiling - Lay-in Tile 16 SF
Lean Too 01 SF64-CLLI-001-B-0016 Smokin Hole
0NAD; Fibrous 80%, Perlite 20%
2019 1
White and Brown fibrous.Ceiling - Lay-in Tile 17 SF
Lean Too 01 SF64-CLLI-001-B-0017 Restroom Hallway roofing materials, window glazings, insulations, or any other construction materials disturbed will require the material to be assumed positive or samples must be conducted to determine if the materials are asbestos containing prior to any disturbance.
0NAD; Fibrous 5%, Calcite 95%
2019 1
Gray.Floor Leveling Compound 18 SF
Lean Too 01 SF64-FLC-001-B-0018 Msn Planning-1
0NAD; Fibrous 5%, Calcite 95%
2019 1
Gray.Floor Leveling Compound 19 SF
Lean Too 01 SF64-FLC-001-B-0019 Msn Planning-2
0NAD; Fibrous 5%, Calcite 95%
2019 1
Gray.Floor Leveling Compound 20 SF
Lean Too 01 SF64-FLC-001-B-0020 Msn Planning-3
0NAD; Non-fibrous 60%, Calcite 40%
2019 1
12"x12" Black and White CheckerFloor Tile 21 SF
Lean Too 01 SF64-FLTL-001-B-0021 NW Hallway
0NAD; Non-fibrous 60%, Calcite 40%
2019 1
12"x12" Black and White CheckerFloor Tile 21 SF
Lean Too 01 SF64-FLTL-001-B-0021 NW Hallway
0NAD; Non-fibrous 60%, Calcite 40%
2019 1
12"x12" GrayFloor Tile 22 SF
Lean Too 01 SF64-FLTL-001-B-0022 Smokin Hole
0Chrysotile 2%, Non-fibrous 98%
2019 1
Off White; Brown fibrousCeiling - Joint Compound 23 SF
Lean Too 01 SF64-CJC-001-B-0023 Smokin Hole
0Chrysotile 2%, Non-fibrous 98%
2019 1
Off WhiteCeiling - Joint Compound 24 SF
Lean Too 01 SF64-CJC-001-B-0024 NW Hallway
0NAD; Non-fibrous 50%, Calcite 50%
2019 1
Tan; Brown fibrousCeiling - Barrier Material 25 SF
Lean Too 01 SF64-CBM-001-B-0025 Smokin Hole
0NAD; Non-fibrous 100%
2019 1
Tan; Brown fibrousCeiling - Barrier Material 25 SF
Lean Too 01 SF64-CBM-001-B-0025 Smokin Hole
0NAD; Cellulose 5%, Gypsum 95%
2019 1
Off White; Brown fibrousCeiling - Sheetrock 26 SF
Lean Too 01 SF64-CLSH-001-B-0026 Smokin Hole
0Chrysotile 20%, Non-fibrous 80%
2019 1
Off White fibrousPipe Insulation 27 SF
Lean Too 01 SF64-PINS-001-B-0027 NW Hallway
JBSA LBP Inventory Print Report
Lead Based Paint Detected:
Administrative
Square Footage: 29768
Number of Floors: 3
None.dwg
Drawing File Name:
Facility Status: Manned
64.jpg
Photo File Name
Date Constructed: 1931
Facility Number: Facility Name:64 Operations
Facility Owner: 12 MSG/CE
Facility Type:
Facility Address: BASE
Facility Summary Report:
04/24/2013 - Assess area for entomology - All Areas are Negative for LBP
12/13/2013 - Syvia Project - Renovate Equipment Room - All areas are Negative for LBP
08/29/2011 - Workorder 10527 - Paint Exterior Hangar - All peeling paint has been removed and the facility has been prepared by a certified LBP team. The facility is ready to be painted by CEO
Facility Site: JBSA Randolph
ViewFacility Comments:
Facility Comments:
Date User Comment
3/14/2019 elv Project, Renovate Lean-to. All areas are Negative for Lead Based Paint. This does not include any hidden wall surfaces. If any sheetrock is removed during this project, the hidden walls if painted will have to be re-evaluated
7/23/2018 elv Work Order 13413- Assess heritage room, men's restroom, Training rooms and Restrooms West for expansion. All areas are negative for Lead Based Paints.
7/1/2018 elv Numerous areas contain Lead Based Paint. See attached report.
Since this facility was built before 1978 it is common for components to contain Lead Based Paint. Any disturbance of Lead Based Paint materials in this facility must be done by a certified Lead Firm. An work in this facility that disturbs Lead Based Paint is governed by OSHA 29 CFR 1926,62, Lead IN Construction rules. This applies to any amount of Lead in Construction Processes.
2/28/2017 elv Work Order 12108 - relocate Doors in Scheduling and training - all areas are negative for Lead Based Paint
10/26/2015 HMUser Work Order 12137 - bat Proof hangar. All exterior paint is Positive for Lead Based Paints. Do not disturb any areas that are POS for LBP by any abrasive means such as sanding, scraping
3 3/14/2019 0.00087Msn Planning A Center Wall Drywall N/A Intact Negativ
4 3/14/2019 0.00097Msn Planning C Center Wall Drywall N/A Intact Negativ
5 3/14/2019 0.00098Msn Planning D Center Wall Drywall N/A Intact Negativ
6 3/14/2019 0.0010ADO A Center Wall Drywall N/A Intact Negativ
7 3/14/2019 0.00078ADO B Center Wall Drywall N/A Intact Negativ
8 3/14/2019 0.00097ADO C Center Wall Drywall N/A Intact Negativ
9 3/14/2019 0.00095ADO D Center Wall Drywall N/A Intact Negativ
10 3/14/2019 0.00109ADO D Right Door Casing Metal N/A Intact Negativ
11 3/14/2019 0.00067CAP A Center Wall Drywall N/A Intact Negativ
12 3/14/2019 0.00092CAP B Center Wall Drywall N/A Intact Negativ
13 3/14/2019 0.00099CAP C Center Wall Drywall N/A Intact Negativ
14 3/14/2019 0.00104CAP D Center Wall Drywall N/A Intact Negativ
15 3/14/2019 0.001CAP B Left Door Casing Metal N/A Intact Negativ
16 3/14/2019 0.0011CAP C Left Door Casing Metal N/A Intact Negativ power washing, blasting, drilling or any brazing/welding operations etc. OSHA 29 CFR 1926.62 Lead in Construction Rules will apply for this project. The OSHA requirement for these rules apply for any amount of LBP .1 mg/cm2 or greater Contain all paint debris and dust. Conduct a TCLP for Lead at a TCEQ certified Lab, TCLP will determine disposal requirements.
Provide a copy of analysis to JBSA specific environmental Office for review and further action.
All materials including all paint chips and debris must be stored in plastic bags in lockable containers until waste characterization has been determined by TCLP analysis. All containers must be lined with plastic sheeting or contain a plastic liner.
All metal with Lead Based Paint may be recycled at an approved metal recycling facility. The receiver of the metal must provide an acceptance letter and a copy provided to the area specific environmental office as proof that the recycling facility will accept metal with Lead Based Paint. All RCRA metal will be manifested for recycling also. A copy of the weight will be provided in order for the Environmental Office to document landfill diversion rates.
All of this must be included in the contract documents
8/27/2015 elv Work Order 11993 Re-attach Drain Spout. All exterior surfaces are Positive for lead Based Paint at the OSHA level of any amount. Do not disturb by any mechanical means such as sanding, drilling, cutting or welding. OSHA 29CFR1926.62 rules will apply to this work order
7/7/2015 elv Work Order 11856 - Paint exterior of Hangar. The following areas are Positive for Lead Based Paints. All concrete wall surfaces, all Drain Pipes. All Exterior electrical conduit. Boiler Room Difuser, Down spout near boiler room, All Window casings, mullions, panes on hangar doors, Mechanical Doors, All Metal on Hangar Doors and Personal Access. Do not disturb any areas that are POS for LBP by any abrasive means such as sanding, scraping blasting, drilling or any brazing/welding operations.etc. OSHA 29 CFR 1926.62 rules will apply for this project. All work must be done by a Lead Certified Firm. The OSHA requirement for these rules apply for any amount of LBP .1 mg/cm2 or greater. A negative determination will be required for this project by a certified Lead Firm before anyone other than a Lead certified worker can disturb the existing LBPpaint by any chemical or abrasive means. The use of Pressure washers to stabilize or abate Lead Based Paint is unauthorized. A TCLP will be required for Lead to determine proper disposal.
17 3/14/2019 0.00094Hallway A Center Wall Drywall N/A Intact Negativ
18 3/14/2019 0.00083Hallway A Center Wall Drywall N/A Intact Negativ
19 3/14/2019 0.00094Hallway A Center Wall Drywall N/A Intact Negativ
20 3/14/2019 0.00096Hallway B Center Wall Drywall N/A Intact Negativ
21 3/14/2019 0.00098Hallway C Center Wall Drywall N/A Intact Negativ
22 3/14/2019 0.00098Hallway C Center Wall Drywall N/A Intact Negativ
23 3/14/2019 0.00078Hallway C Center Wall Drywall N/A Intact Negativ
24 3/14/2019 0.00094Hallway C Center Wall Drywall N/A Intact Negativ
25 3/14/2019 0.00105Hallway C Center Wall Drywall N/A Intact Negativ
26 3/14/2019 0.00098Hallway B Right Door Casing Metal N/A Intact Negativ
27 3/14/2019 0.00958Hallway B Left Door Casing Metal N/A Intact Negativ
28 3/14/2019 0.0947Hallway B Left Door Casing Metal N/A Peeling Negativ
29 3/14/2019 0.00108Hallway B Center Door Metal N/A Chaffing Negativ
ASBESTOS REPORT: HANGAR 12
Project :
Project # :
Identification :
Test Method :
JBSA Randolph - 802 CES / CEIE
RND 12, Multi Room Project
8668927
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 12/11/2020, thirty two (32) bulk material samples were submitted by Edward Vogel of JBSA Randolph - 802 CES / CEIE for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
20B-13069
12/09/2020
12/17/2020
NVLAP Lab Code 102056-0
TDSHS License No. 30-0084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
12-WLSH-001-B-
Chalky; Gran (Off-White), Hall Outside Room 4 None Detected - Drywall Material
12-WLSH-001-B-
North; Chalky; Gran (Off-White), Room 4, In None Detected - Drywall Material
12-WLSH-001-B-
Chalky; Gran (Off-White), Room 8 None Detected - Drywall Material
12-WLSH-001-B-
Chalky; Gran (Off-White), Room 8, Inner None Detected - Drywall Material
2% Chrysotile - Joint Compound
( By PLM )
1.75% Chrysotile - Joint Compound
( By Point Count )
12-WLSH-001-B-
Chalky; Gran; Fibrous (Off-White), Room 9, Outer None Detected - Drywall Material
12-WLSH-001-B-
Chalky; Gran (Off-White), Room 10, Inner None Detected - Drywall Material
12-WLSH-001-B-
Chalky; Gran; Fibrous (Off-White) Room 10, Outer None Detected - Drywall Material
12-WLSH-001-B-
Chalky; Gran; Fibrous (Beige), Room 16, Inner None Detected - Drywall Material
None Detected - Acoustic Texture
12-WLSH-001-B-
Chalky; Gran; Fibrous (Beige), Room 16, Outer None Detected - Drywall Material
12-WLSH-001-B-
Chalky; Gran; Fibrous (Off-White), Room 18, Inner None Detected - Drywall Material
<1% Chrysotile - Textured Paint
( By PLM )
0.75% Chrysotile - Textured Paint
( By Point Count )
12-WLSH-001-B-
Chalky; Gran; Fibrous (Beige), Room 18, Outer None Detected - Drywall Material
12-WLJ-001-B-
Chalky; Gran (Off-White), Room 4 None Detected - Joint Compound
Project :
Project # :
Identification :
Test Method :
JBSA Randolph - 802 CES / CEIE
RND 12, Multi Room Project
8668927
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 12/11/2020, thirty two (32) bulk material samples were submitted by Edward Vogel of JBSA Randolph - 802 CES / CEIE for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
20B-13069
12/09/2020
12/17/2020
NVLAP Lab Code 102056-0
TDSHS License No. 30-0084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
12-WLJ-001-B-
Chalky; Gran (Off-White), Outside Room 4, Hall None Detected - Joint Compound
12-WLJ-001-B-
Chalky; Gran (Off-White), Room 8 None Detected - Texture
12-WLJ-001-B-
Chalky; Gran (Off-White), Room 9, Outer None Detected - Joint Compound
12-WLJ-001-B-
Chalky; Gran (Off-White), Room 10 None Detected - Joint Compound
12-WLJ-001-B-
Chalky; Gran (Off-White), Room 16, Inner None Detected - Joint Compound
12-WLJ-001-B-
Chalky; Gran (Off-White), Room 16, Outer None Detected - Joint Compound
12-WLJ-001-B-
Chalky; Gran (Off-White), Room 18, Outer None Detected - Joint Compound
12-CLLI-001-B-
2' x 2' Coarse Ceiling Tile; Fibrous (Gray and White), Room
None Detected - Acoustic Tile
12-CLLI-001-B-
2' x 2' Coarse Ceiling Tile; Fibrous (Gray and White), Room
None Detected - Acoustic Tile
12-CLLI-001-B-
2' x 2' Coarse Ceiling Tile; Fibrous (Gray and White), Room
None Detected - Acoustic Tile
12-CLLI-001-B-
2' x 2' Coarse Ceiling Tile; Fibrous (Gray and White), Room
None Detected - Acoustic Tile
12-WLTX-001-B-
Gran (Off-White); Brown Paper, Room 4 None Detected - Textured Paint
12-WLTX-001-B-
Gran (Off-White); Brown Paper, Room 9 None Detected - Texture
12-WLTX-001-B-
Gran (Off-White); Brown Paper, Room 10, Out None Detected - Drywall Material
None Detected - Textured Paint
Project :
Project # :
Identification :
Test Method :
JBSA Randolph - 802 CES / CEIE
RND 12, Multi Room Project
8668927
Asbestos, Bulk Sample Analysis
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 12/11/2020, thirty two (32) bulk material samples were submitted by Edward Vogel of JBSA Randolph - 802 CES / CEIE for asbestos analysis by
PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Lab Job No. :
Report Date :
20B-13069
12/09/2020
12/17/2020
NVLAP Lab Code 102056-0
TDSHS License No. 30-0084
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
12-WLTX-001-B-
Gran (Off-White); Brown Paper, Room 10, In None Detected - Drywall Material
<1% Chrysotile - Textured Paint
( By PLM )
0.50% Chrysotile - Textured Paint
( By Point Count )
12-CLSP-001-B-
Fibrous (Brown), Room 4 None Detected - Fiber Board
12-CLSP-001-B-
Fibrous (Brown), Room 8 None Detected - Fiber Board
12-CLSP-001-B-
Fibrous (Brown), Room 10 None Detected - Fiber Board
12-CLSP-001-B-
Fibrous (Brown), Room 16 None Detected - Fiber Board
12-FLMAS-001-B-
Not Provided None Detected - Mastic
Hillary Tuerck, Shaun Wilkerson, Heather LopezAnalyst(s):
Lab Director : Bruce Crabb Approved Signatory :
Thank you for choosing Moody Labs
Lab Manager : Heather Lopez Approved Signatory :
These samples were analyzed by layers. Quantification, unless otherwise noted, is performed by calibrated visual estimate. The test report shall not be reproduced, except in full, without written approval of the laboratory. The results relate only to the items tested. These test results do not imply endorsement by NVLAP or any agency of the U.S.
Government. Accredited by the National Voluntary Laboratory Accreditation Program for Bulk Asbestos Fiber Analysis under Lab Code 102056-0.
This Page Left Intentionally Blank
Project # : 8668927
Sample Number Layer Components % Of
Sample
Analysis
Date
% of
Layer Analyst
Supplement to PLM Summary Report
Client :
Project :
JBSA Randolph - 802 CES / CEIE
RND 12, Multi Room Project
Lab Job No. :
Report Date :
20B-13069 002
12/17/2020
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
Moody Labs NVLAP Lab Code 102056-0
TDSHS License No. 30-0084
Glass Wool Fibers12-WLSH-001-B-
Drywall Material (Light Pink) 100% 12/162% HT
Cellulose Fibers12-WLSH-001-B-
Drywall Material (Light Pink) 100% 12/161% HT
Gypsum / Binders12-WLSH-001-B-
Drywall Material (Light Pink) 100% 12/1697% HT
Glass Wool Fibers12-WLSH-001-B-
Drywall Material (Light Pink) 100% 12/162% HT
Cellulose Fibers12-WLSH-001-B-
Drywall Material (Light Pink) 100% 12/161% HT
Gypsum / Binders12-WLSH-001-B-
Drywall Material (Light Pink) 100% 12/1697% HT
Glass Wool Fibers12-WLSH-001-B-
Drywall Material (Light Pink) 100% 12/162% HT
Cellulose Fibers12-WLSH-001-B-
Drywall Material (Light Pink) 100% 12/161% HT
Gypsum / Binders12-WLSH-001-B-
Drywall Material (Light Pink) 100% 12/1697% HT
Cellulose Fibers12-WLSH-001-B-
Drywall Material (White) 64% 12/165% HT
Gypsum / Binders12-WLSH-001-B-
Drywall Material (White) 64% 12/1695% HT
Cellulose Fibers12-WLSH-001-B-
DW Paper Facing (Tan) 1% 12/16100% HT
Chrysotile
(1.75% Chrysotile)
12-WLSH-001-B-
Joint Compound (White) 35% 12/162% HT12/16
12/17
HT
HL
Calcite / Talc / Binders12-WLSH-001-B-
Joint Compound (White) 35% 12/1698% HT
Glass Wool Fibers12-WLSH-001-B-
Drywall Material (Light Pink) 95% 12/162% HT
Gypsum / Binders12-WLSH-001-B-
Drywall Material (Light Pink) 95% 12/1698% HT
Cellulose Fibers12-WLSH-001-B-
DW Paper Facing (Tan) 5% 12/16100% HT
Sample Number Layer Components % Of
Sample
Analysis
Date
% of
Layer Analyst
Supplement to PLM Summary Report
Client :
Project :
JBSA Randolph - 802 CES / CEIE
RND 12, Multi Room Project
Lab Job No. :
Report Date :
20B-13069 002
12/17/2020
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
Moody Labs NVLAP Lab Code 102056-0
TDSHS License No. 30-0084
Cellulose Fibers12-WLSH-001-B-
Drywall Material (Light Pink) 100% 12/165% HT
Gypsum / Binders12-WLSH-001-B-
Drywall Material (Light Pink) 100% 12/1695% HT
Glass Wool Fibers12-WLSH-001-B-
Drywall Material (Light Pink) 95% 12/162% HT
Gypsum / Binders12-WLSH-001-B-
Drywall Material (Light Pink) 95% 12/1698% HT
Cellulose Fibers12-WLSH-001-B-
DW Paper Facing (Tan) 5% 12/16100% HT
Glass Wool Fibers12-WLSH-001-B-
Drywall Material (Light Pink) 90% 12/162% HT
Gypsum / Binders12-WLSH-001-B-
Drywall Material (Light Pink) 90% 12/1698% HT
Cellulose Fibers12-WLSH-001-B-
DW Paper Facing (Tan) 7% 12/16100% HT
Perlite12-WLSH-001-B-
Acoustic Texture (Off-White) 3% 12/1615% HT
Calcite / Talc / Binders12-WLSH-001-B-
Acoustic Texture (Off-White) 3% 12/1685% HT
Glass Wool Fibers12-WLSH-001-B-
Drywall Material (Light Pink) 100% 12/162% HT
Cellulose Fibers12-WLSH-001-B-
Drywall Material (Light Pink) 100% 12/161% HT
Gypsum / Binders12-WLSH-001-B-
Drywall Material (Light Pink) 100% 12/1697% HT
Sample Number Layer Components % Of
Sample
Analysis
Date
% of
Layer Analyst
Supplement to PLM Summary Report
Client :
Project :
JBSA Randolph - 802 CES / CEIE
RND 12, Multi Room Project
Lab Job No. :
Report Date :
20B-13069 002
12/17/2020
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
Moody Labs NVLAP Lab Code 102056-0
TDSHS License No. 30-0084
Glass Wool Fibers12-WLSH-001-B-
Drywall Material (White) 80% 12/162% HT
Cellulose Fibers12-WLSH-001-B-
Drywall Material (White) 80% 12/161% HT
Gypsum / Binders12-WLSH-001-B-
Drywall Material (White) 80% 12/1697% HT
Cellulose Fibers12-WLSH-001-B-
DW Paper Facing (Tan) 17% 12/16100% HT
Chrysotile
(0.75% Chrysotile)
12-WLSH-001-B-
Textured Paint (Off-White) 3% 12/16<1% HT12/16
12/17
HT
HL
Calcite12-WLSH-001-B-
Textured Paint (Off-White) 3% 12/1620% HT
Pigment / Binders12-WLSH-001-B-
Textured Paint (Off-White) 3% 12/1680% HT
Glass Wool Fibers12-WLSH-001-B-
Drywall Material (White) 100% 12/162% SW
Cellulose Fibers12-WLSH-001-B-
Drywall Material (White) 100% 12/161% SW
Gypsum / Binders12-WLSH-001-B-
Drywall Material (White) 100% 12/1697% SW
Calcite / Talc / Binders12-WLJ-001-B-
Joint Compound (White) 100% 12/16100% SW
Glue Binders12-WLJ-001-B-
Yellow Mastic (Yellow) 10% 12/16100% SW
Calcite / Talc / Binders12-WLJ-001-B-
Joint Compound (White) 90% 12/16100% SW
Calcite / Talc / Binders12-WLJ-001-B-
Texture (White) 100% 12/16100% SW
Calcite / Talc / Binders12-WLJ-001-B-
Joint Compound (White) 100% 12/16100% SW
Calcite / Talc / Binders12-WLJ-001-B-
Joint Compound (White) 100% 12/16100% SW
Calcite / Talc / Binders12-WLJ-001-B-
Joint Compound (White) 100% 12/16100% SW
Calcite / Talc / Binders12-WLJ-001-B-
Joint Compound (White) 100% 12/16100% SW
Sample Number Layer Components % Of
Sample
Analysis
Date
% of
Layer Analyst
Supplement to PLM Summary Report
Client :
Project :
JBSA Randolph - 802 CES / CEIE
RND 12, Multi Room Project
Lab Job No. :
Report Date :
20B-13069 002
12/17/2020
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
Moody Labs NVLAP Lab Code 102056-0
TDSHS License No. 30-0084
Calcite / Talc / Binders12-WLJ-001-B-
Joint Compound (White) 100% 12/16100% SW
Cellulose Fibers12-CLLI-001-B-
Acoustic Tile (Tan) 100% 12/1650% SW
Mineral Wool Fibers12-CLLI-001-B-
Acoustic Tile (Tan) 100% 12/1630% SW
Perlite12-CLLI-001-B-
Acoustic Tile (Tan) 100% 12/1620% SW
Cellulose Fibers12-CLLI-001-B-
Acoustic Tile (Tan) 100% 12/1650% SW
Mineral Wool Fibers12-CLLI-001-B-
Acoustic Tile (Tan) 100% 12/1630% SW
Perlite12-CLLI-001-B-
Acoustic Tile (Tan) 100% 12/1620% SW
Cellulose Fibers12-CLLI-001-B-
Acoustic Tile (Tan) 100% 12/1650% SW
Mineral Wool Fibers12-CLLI-001-B-
Acoustic Tile (Tan) 100% 12/1630% SW
Perlite12-CLLI-001-B-
Acoustic Tile (Tan) 100% 12/1620% SW
Cellulose Fibers12-CLLI-001-B-
Acoustic Tile (Tan) 100% 12/1650% SW
Mineral Wool Fibers12-CLLI-001-B-
Acoustic Tile (Tan) 100% 12/1630% SW
Perlite12-CLLI-001-B-
Acoustic Tile (Tan) 100% 12/1620% SW
Calcite12-WLTX-001-B-
Textured Paint (Off-White) 100% 12/1620% SW
Pigment / Binders12-WLTX-001-B-
Textured Paint (Off-White) 100% 12/1680% SW
Cellulose Fibers12-WLTX-001-B-
DW Paper Facing (Tan) 5% 12/16100% SW
Calcite / Talc / Binders12-WLTX-001-B-
Texture (White) 95% 12/16100% SW
Sample Number Layer Components % Of
Sample
Analysis
Date
% of
Layer Analyst
Supplement to PLM Summary Report
Client :
Project :
JBSA Randolph - 802 CES / CEIE
RND 12, Multi Room Project
Lab Job No. :
Report Date :
20B-13069 002
12/17/2020
2051 Valley View Lane
Farmers Branch, TX 75234 Phone: (972) 241-8460
Moody Labs NVLAP Lab Code 102056-0
TDSHS License No. 30-0084
Glass Wool Fibers12-WLTX-001-B-
Drywall Material (White) 10% 12/162% SW
Cellulose Fibers12-WLTX-001-B-
Drywall Material (White) 10% 12/161% SW
Gypsum / Binders12-WLTX-001-B-
Drywall Material (White) 10% 12/1697% SW
Cellulose Fibers12-WLTX-001-B-
DW Paper Facing (Tan) 20% 12/16100% SW
Calcite12-WLTX-001-B-
Textured Paint (Off-White) 70% 12/1620% SW
Pigment / Binders12-WLTX-001-B-
Textured Paint (Off-White) 70% 12/1680% SW
Glass Wool Fibers12-WLTX-001-B-
Drywall Material (White) 20% 12/162% SW
Cellulose Fibers12-WLTX-001-B-
Drywall Material (White) 20% 12/161% SW
Gypsum / Binders12-WLTX-001-B-
Drywall Material (White) 20% 12/1697% SW
Cellulose Fibers12-WLTX-001-B-
DW Paper Facing (Tan) 79% 12/16100% SW
Chrysotile
(0.50% Chrysotile)
12-WLTX-001-B-
Textured Paint (White) 1% 12/16<1% SW12/16
12/17
SW
HL
Pigment / Binders12-WLTX-001-B-
Textured Paint (White) 1% 12/16100% SW
Wood Fibers12-CLSP-001-B-
Fiber Board (Tan) 100% 12/16100% SW
Wood Fibers12-CLSP-001-B-
Fiber Board (Tan) 100% 12/16100% SW
Wood Fibers12-CLSP-001-B-
Fiber Board (Tan) 100% 12/16100% SW
Wood Fibers12-CLSP-001-B-
Fiber Board (Tan) 100% 12/16100% SW
Glue Binders12-FLMAS-001-
B-0032
Mastic (Yellow) 100% 12/16100% SW
JBSA Asbestos…