Arkansas Valley Conduit - Crowley Reach 1
Solicitation number
140R6026R0001
Issued by

About this file

This is a technical drawing document providing engineering specifications and location mapping for the Crowley Reach 1 (CR1) segment of the Arkansas Valley Conduit project. The drawing, created in AutoCAD 25.0 and last updated September 17, 2025, depicts the project site location in Colorado spanning from Boone to Crowley, with the CR1 segment beginning at coordinates N = 1577961.11, E = 3356268.53 and connecting to Reach 2 (BR2). The document includes a location map showing the conduit route relative to State Highways 96 and 209, U.S. Highway 50, the Colorado Canal, and the Arkansas River in the southern Colorado area.

The drawing establishes pipe classification standards for the project using a designation system where the first two digits indicate nominal pipe diameter in inches for HDPE pipe, followed by a letter designating soil cover class ranges. The document references Specification Section 33 11 10 Pipeline General Requirements for pipe equivalents and nominal diameter specifications across different pipe materials. The project is managed by the Bureau of Reclamation under the U.S. Department of the Interior's Water Management systems, with the CAD file identified as 382-D-60614-RD-1.DWG and saved by user BZOOK.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S ta te H ig hw ay

Colorado Canal

Boo ne

Rd

State Highway 96

U.S. Highway 50

Boone

State Highway 96

Arkansas River

Colorado Canal

Flow

Kansas Utah

Wyoming Nebraska

New Mexico

Arizona Texas

Oklahoma

Colorado

Source: Esri, Maxar, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the GIS User Community Powered by Esri

ALWAYS THINKSAFETYSHEET5DC43BA54321DC2BA1BUREAU OF RECLAMATIONU.S. DEPARTMENT OF THE INTERIORManagingLARM TAIOCENWintheWaestterCAD SYSTEMAutoCAD 25.0sCAD FILENAME382-D-60614-RD-1.DWGLAST SAVED DATE2025-09-17LAST SAVED BYBZOOKPRJ-STA-SEQ

Boone

Avondale

Pueblo

Fowler Manzanola

Crowley Olney Springs

Rocky Ford

Ordway

0 10000'5000'

Project Site

Crowley Reach 1 (CR1)

Start CR1 - Connection to BR2

N = 1577961.11 E = 3356268.53

LOCATION MAP

PIPE CLASSIFICATIONS

For an example designation of 36B250.

· The 36 indicates the nominal pipe diameter in inches for a HDPE pipe.

See Specification Section 33 11 10 Pipeline General Requirements pipe equivalents table of nominal pipe diameters for different pipe materials.

· B represents a range of soil cover over the pipe. The letter represents a soil cover class of 0.0'<A<5.0', 5.0'<B <10.0', 10.0'<C<15.0', and 15.0'<D<20.0'.

· 250 indicates the maximum sustained operating pressure head in feet of head permitted for the pipe within the designated limits.

NOT TO SCALE

KEY MAP

NOT TO SCALE

VICINITY MAP

Project Site

Pueblo County

End CR1 N = 1564312.64 E = 3379018.57

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

5.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 9-

LA

S T

S A V

ED

B Y

B Z O

O K

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

C T

A R K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

KEY, LOCATION AND

VICINITY MAPS

GENERAL NOTES AND

PIPE CLASSIFICATIONS

DENVER, CO

382-D-60614

2025-03-13

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

£TT£

£AT£

£AA£

£TA£

K. WHITESELL

K. KEARNS

B. ZOOK

GENERAL NOTES

1. General Notes, Symbols, Abbreviations, and Pipe Classifications apply to all drawings.

2. At angle points that do not require miter bends, long radius curves

(vertical and horizontal) shall be constructed by pulling joints.

3. Minimum earth cover over top of the pipe shall be 3.5 feet unless the line pipe is at an existing wash, within a CDOT ROW, or within 15.0 feet of a roadway, and then the minimum cover is 5.0 feet, unless otherwise noted.

4. Where the line pipe crosses an existing pipe, a minimum clear distance of

2.0 feet outside to outside between line pipe and existing pipe shall be provided unless otherwise directed by COR. The backfill between the crossing pipe shall be controlled low strength material (CLSM) as stated in the specifications.

5. For limits of excavation near gas lines, see Specifications.

6. Grid based on Colorado State Plane, Southern Zone Coordinate System.

North American Horizontal datum of 1983 (NAD83) and North American Vertical datum of 1988 (NAVD88) in U.S. survey feet.See reference drawings in Specifications Section 52 00 for survey control points information.

7. Ground to grid conversion factor is 0.9997713902, base point (0,0).

8. The Contractor shall follow Colorado Department of Transportation (CDOT) erosion control requirements when working within CDOT's right-of-way.

CDOT's Erosion Control & Stormwater Quality Guide can be found on-line at codot.gov/programs/environmental/water-quality/ construction-sites-program.

9. Open cut CDOT roads require CLSM and compacted backfill per Specifications. Non-CDOT roads require gravel surfacing per Specifications.See (60663) for details.

10. Existing utility poles within 5.0 feet of estimated excavation limits will need to be stabilized when digging.

11. CAUTION: Call Colorado OneCall 811 before you dig.

12. Shored and standard trenches are noted on profiles. See typical trench details on (60617).

13. Fiber optic pull boxes and splice vaults per Specifications. Fiber optic conduit not shown on drawings for clarity.

14. Contractor shall provide and maintain (in a safe condition) temporary approaches or crossings and intersections with trails, roads, streets, businesses, parking lots, residences, garages, and farms.

15. Contractor must adhere to Union Pacific Railroad requirements for Union Pacific Railroad crossing which includes but is not limited to: track and ground monitoring and continuous (24/7) construction within 25.0 feet of track centerline. Other requirements may be found in the railroad crossing packages in Division 51 of the Specifications.

16. See Specifications for easement legal descriptions.

17. See Specifications for Option A description and requirements.

Option A

¦D_DT¦

PEER REVIEWER

State Highw ay 209

BOONE

State Highway 96

3000+00.00 N=1577961.11 E=3356268.53Stat e H ighway

Colorado Canal

State Highway 96

3277+34.82 N=1564312.64 E=3379018.57

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER -

K. WHITESELL

K. KEARNS

B. ZOOK

0 2000'1000'

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 3-

LA

S T

S A V

ED

B Y

K K

EA

R N

S

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

C T

A R K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

KEY INDEX

DENVER, CO

382-D-60615

Start reach 3000+00.00

Match line 3022+00

Match line 3066+00

Match line 3088+00

Match line 3110+00

Match line 3132+00

Match line 3154+00

Match line 3176+00

(60619)

(60621)

(60623) (60625) (60628)

(60629) (60631)

(60634)

(60637)

(60639) (60642)

(60641) (60643)

Match line 3044+00

Match line 3198+00

Match line 3209+00

Match line 3231+00

Match line 3253+00

End reach 3277+34.82

(60638)

CR1

CR1

(60635)

Match line 3011+00

Match line 3055+00

Match line 3077+00

Match line 3099+00

Match line 3121+00

Match line 3143+00

Match line 3165+00

Match line 3033+00

Match line 3187+00

Match line 3220+00

Match line 3209+00

Match line 3242+00

Match line 3264+00

(60620)

(60622)

(60624) (60626) (60627) (60630)

(60632) (60633)

(60636)

(60645)

Match line 3275+00

(60644)

KEY INDEX

¦D_DT¦DENVER, CO 2025-03-14

TECH. APPR.

APPROVED

PEER REVIEWER -

Orpineda, Crystal M P.E.

Steen, Timothy M P.E.

TECH. APPR.

APPROVED

PEER REVIEWER -

Orpineda, Crystal M P.E.

Steen, Timothy M Supervisor Water Conveyance 2

APPROVED £AT£

See Note 3 for warning tape Restore surface to original grade and condition

CLSM or undisturbed earth

Additional excavation as required in rock.

Replace with CLSM or compacted backfill as directed. See Specifications for depth requirements.

Optional bench, where required for safety

Shored trench option

Original ground surface

Cl. pipe

T

OD

Restricted size backfill, see Specifications

Maximum height between benches varies as required for safety

TYPICAL SECTION - CLSM TRENCHA

Not to scale

3.

0' m in

7.5' min.

CLSM or undisturbed earth

Compacted backfill in CDOT ROW, see Specifications

W5

Fiber optic conduit, see Specifications for structure locations

CLSM

Min. 1.0'

See Note 3 for warning tape

Standard trench, slope as required for safety

H1:1

0.

O D

Min. 0.5'

DETAIL - PIPE INSTALLATION WITH SOIL PADS, TYPICAL FOR ALL PIPES1

CLSM

"X" min., see Soil pad table

CLSM

"X" min., see Soil pad table

CLSM

L/5

L = Length of pipe furnished, 55'-0" max.

ID

L/5

Rock, typ.Soil, typ.

Connection type may vary by pipe material (bell & spigot, welding, fusion, etc.), required spacing shown is typical for all pipes.

Not to scale

OD

Shored trench option

Standard trench, slope as required for safety

W1 B W2

H1:1

Compacted embedment 0.70D

W3

T

Pi pe

C ov er Compacted backfill in CDOT ROW, see Specifications

Fiber optic conduit, see Specifications for structure locations

3.

0' m in

7.5' min.

TYPICAL SECTION - SELECT MATERIAL TRENCHB

See Note 3 for warning tape

Restore surface to original grade and condition

6" min. additional excavation if required in unsuitable material as directed. Replaced with compacted backfill per Specifications.

Bedding

Restricted size backfill, see Specifications

See Note 3 for warning tape

Not to scale

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

£TT£

£AT£

£AA£

£TA£

K. WHITESELL

K. KEARNS

B. ZOOK

NOTES

1. OD is the outside diameter of the pipe actually installed.

2. Sloping, shoring, and benching shall be in accordance with the

Specifications.

3. Warning tape and tracer wire not shown on all drawings, but are required. See Specifications for details.

4. CLSM is required for bedding and embedment when the native trench material's Plasticity Index exceeds 25.

5. CLSM is required for embedment when saturated soil is encountered in the pipe trench.

6. CLSM backfill, if used, cannot exceed 5'-0" vertical until CLSM embedment reaches an unconfined compressive strength of 30 psi.

7. Actual pipe trench soil properties will determine the trench type. See

Specifications for additional information.

8. Install pipe based on Specifications or pipe manufacturer's recommendations, whichever is more stringent.

9. See Specifications for CDOT Utility Special Use Permit Standard

Provisions for additional asphalt replacement requirements.

10. For native material properties, see Specifications.

11. See Specifications for CDOT Utility Accommodations Code for fiber utility requirements.

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

5.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 9-

LA

S T

S A V

ED

B Y

K K

EA

R N

S

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

C T

A R K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

TYPICAL TRENCH

DETAILS

DENVER, CO

382-D-60617

1 H1 defines required side slopes within the bedding and embedment zone, min.

2 Requires CLSM for bedding and embedment.

3 T defines minimum bedding thickness between pipe and excavation limits.

4 See (60661) for special encasement details.

5 Gap in stations is due to trenchless installation, see (60666).

6 See (60628-60629) for extents of Option A.

SELECT MATERIAL GRADATION

LIMITS

Size6 Percent by Weight

Passing No. 200 sieve 12 or less

Passing No. 50 sieve 25 or less

6 Maximum size shall not exceed 34-inch

SOIL PAD TABLE

PIPE ID "X"

12" - 27" .05L

30" - 66" .10L

SOIL PAD NOTE

1. Soil pads allow observation of the soil-cement slurry flowing from one side of the pipe to the other.

6" Aggregate Base Course

Trench width

Prime coat

Tack coat

Saw cut

Compacted backfill, see

Specifications

2" lifts of Asphalt Concrete Pavement, see Note 9

12" Aggregate Base Course

Trench width

TYPICAL TRENCH DIMENSIONS

Select Fill CLSM

Pipe Type Station Range5 Nominal Pipe Size (In) D (In) T (In)3 H1

(Ft) B (In) W1 (In) W2 (In) W3 (In) W5 (In)

HDPE4 3000+00.00 To 3009+35.00 36 36 - 1.5 - - - - -

HDPE 3029+80.00 To 3091+80.00 36 36 4 0.75 116 72 115.8 34.5 60

HDPE2 3091+80.00 To 3106+86.07 3108+21.78 To 3115+60.00 36 36 4 0.75 116 72 115.8 34.5 60

HDPE2 3115+60.00 To 3277+34.82 36 36 4 1.5 116 72 159.6 51 60

Casing2 3110+07.00 To 3112+82.00 48 49.3 4 0.75 126 84 140.4 39 72

Casing2 3117+75.00 To 3118+07.00 48 48.8 4 1.5 168 84 196.8 60 72

DETAIL - ASPHALT SURFACE REPLACEMENT2

DETAIL - GRAVEL SURFACE REPLACEMENT3

Compacted backfill, see

Specifications

For replacement in

CDOT ROW,

see Note 9

1.

0'

1.

0'

See Note 1.

Not to scale

Geotextile

Geotextile

EL

EV

A

TI

O N

STATION

3000+00 3050+00 3100+00 3150+00 3200+00 3250+00 3278+77

.0

B lo w of f w ith m an ho le

.0

B lo w of f w ith m an ho le

.0

B lo w of f w ith m an ho le

.0

B lo w of f w ith m an ho le

.0

B lo w of f w ith m an ho le

.0

B lo w of f w ith m an ho le

.0

B lo w of f w ith m an ho le

.0

S ec tio n va lv e

.0

S ec tio n va lv e

.0

S ec tio n va lv e

.0

A ir v al ve

.4

A ir v al ve

.0

A ir v al ve

.0

A ir v al ve

.0

A ir V al ve w ith m an ho le

.0

S am pl in g S ta tio n

.0

S am pl in g S ta tio n

.0

A ir v al ve

.0

A ir v al ve

.0

A ir V al ve w ith m an ho le

.8

A ir v al ve

PROFILE

Cl. CR1

Original ground surface

1,500' 3,000'

Note: Vertical scale exaggerated 20x for clarity

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 3-

LA

S T

S A V

ED

B Y

K K

EA

R N

S

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

OVERALL PROFILE

DENVER, CO

382-D-60618

Static hydraulic profile El. 4772.70

NOTES

1. The static hydraulic profile represents the maximum sustained operating pressure for the pipeline.

2. The transient hydraulic profile represents the maximum design pressure for the pipeline.

3. See (60647) to (60650) for air valve assembly.

4. See (60652) and (60653) for blow-off assembly.

5. See (60657) and (60658) for sectionalizing valve assembly.

6. See (60660) for sampling station.

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER -

M. LIN

K. WHITESELL

B. ZOOK

Manager Water Conveyance 2

Transient hydraulic profile El. 4790.00

0'

TECH. APPR.

APPROVED

PEER REVIEWER -

TECH. APPR.

APPROVED

PEER REVIEWER -

Orpineda, Crystal M P.E.

Steen, Timothy M Supervisor Water Conveyance 2

APPROVED £AT£

WM

WM

WM

WM

GM

SS

GM

SS

161'

DH-22-113

DH-22-114

DH-22-115

DH-24-216

FO

A

Culvert, Protect in place

Culvert, Protect in place

Culvert, Protect in place

Start buried gas utility relocate 3002+05.87 N=1,577,940.58 E=3,356,473.37

Start buried telephone utility relocate 3005+17.46 N=1,577,905.01 E=3,356,783.00

End BR2 reach/ Start CR1 reach 3000+00.00 N=1,577,961.11 E=3,356,268.53

End buried gas utility relocate 3004+70.26 N=1,577,915.09 E=3,356,736.53

End buried telephone utility relocate 3007+07.44 N=1,577,887.97 E=3,356,972.22

Bend 3008+85.07 Δ=4°20'54" N=1,577,872.81 E=3,357,149.11

Bend 3007+92.31 Δ=2°37'13" N=1,577,885.34 E=3,357,057.20

Estimated excavation limits

Edge of road Cl. CR1

BR2 - By others

Edge of

ROW

Remove blind flange and connect to BR2.

See Notes 1 and 2.

Proposed fiber optic pull box

.8

.7

.2

S. First St.

R us se ll

A ve

S

C ol le ge

A ve

S

H

M

TC

H L

IN

E

1+

Flow

17.5'

3.4'

Colorado Canal

Bend 3000+50.00 Δ=0°32'22" N=1,577,955.71 E=3,356,318.23

Bend 3004+68.83 Δ=0°31'24" N=1,577,914.35 E=3,356,735.02 T21S

, R 61W

, S

EC

T21S , R

61W , S

EC

.0

A ir v al ve w ith m an ho le

S ee

N ot e an d

.8

B ur ie d ga s lin e

To p

.8

EL

EV

A

TI

O N

STATION

2999+00 3000+00 3002+00 3004+00 3006+00 3008+00 3010+00 3011+00

S=-0.02164

S=0.00415

.2

B ur ie d fib er o pt ic To p

.0

.6

O H e le ct ri c lin e

H ei gh t=

.8

Te m p

.0

B ur ie d fib er o pt ic To p

.4

.5

B ur ie d ga s lin e

To p

.9

H G

L

2.

El. 4450.90

El. 4454.52

En d

B R

R ea ch

S ta rt C

R

R ea ch

.0

1°

'3 8"

-1 0°

'4

8" Ti e in to H

D D

H G

L

5.

Shored trench, see (60617) 36B325

HDD (see 60661)

H G

L

8.

36HDD375

El. 4427.67

Special encasement and fused joints required, see Specifications and (60662)

.5

B ur ie d

6" w at er li ne

To p

.4

.3

B ur ie d w at er li ne To p

.5

.5

Tr en ch p lu g

.5

Tr en ch p lu g

El. 4450.68

B lo w of f w ith m an ho le S ee

N ot e

.8

B ur ie d ga s lin e

To p

.5

.9

B ur ie d w at er li ne To p

.4

.5

B ur ie d te le ph on e To p

.1

.1

B ur ie d te le ph on e To p

.3

Cl. CR1

Original ground surface

Cl. BR2

OPEN-CUT ROAD CROSSINGS

Station

Surfacing Start End

3000+00 3009+35 Gravel

PROFILE

Note: Vertical scale exaggerated 5x for clarity

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER -

K. WHITESELL

K. KEARNS

B. ZOOK

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 3-

LA

S T

S A V

ED

B Y

K W

H

IT

ES

EL

L

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

PLAN AND PROFILE

3000+00 TO 3011+00

DENVER, CO

382-D-60619

PLAN

0 100'50'

1. If Boone reach 2 (BR2) is complete, remove blind flange and connect to BR2. If BR2 is not complete, install blind flange.

2. Prior to backfilling survey and submit coordinates of end of pipe.

3. See Note 14 on (60614) and Specifications for access requirements while trenching through private drives.

4. If the HDD installation is complete and a connection is not being made to the line piping, blind flange if buried and survey and submit coordinates at each end of the HDD pipe prior to backfilling.

5. Adjust location of air valve according to final position of HDD maintaining offset distance shown.

6. See (60663) and Specifications for details of the HDD.

7. See (60661) and Specifications for details of the special encasement.

8. Place two guard posts on traffic facing side of air vent pipe. Provide 2.0' minimum clearance from vent pipe.

Space guard posts 5.0' apart, guard posts shall be located 1.0' minimum from edge of road. Contractor to verify utility locations and avoid conflicts. See (40-D-60002) for guard posts details.

NOTES

TECH. APPR.

APPROVED

PEER REVIEWER -

TECH. APPR.

APPROVED

PEER REVIEWER -

Orpineda, Crystal M P.E.

Steen, Timothy M Supervisor Water Conveyance 2

APPROVED £AT£

GM

GM

GM

WM

WM

GM

GM

SS SS30

DH-24-201

FO

4460 4450

Cl. CR1

Edge of road

Edge of ROW

Proposed permanent easement

Proposed construction easement

Proposed fiber optic pull box

S

H ig hl an d A ve

S

B oo ne A ve

Colorado Canal

S. First St.

TC

H L

2+

TC

H L

Flow

EV

A

TI

O N

STATION

3011+00 3012+00 3014+00 3016+00 3018+00 3020+00 3022+00

.0

O H e le ct ri c lin e

H ei gh t=

4.

2' Te m p

.3

B ur ie d

Fi be r O pt ic

A ss um ed d ep th

.0

.0

O H e le ct ri c lin e

H ei gh t=

5.

1' Te m p

.0

C ol or ad o C an al cr os si ng

36HDD375

HDD, see (60661)

H G

L

5.

H G

L

9.

El. 4414.00

El. 4427.67

El. 4414.00

S=0.00000

.3

B ur ie d te le ph on e A ss um ed d ep th

.0

.9

H G

L

9.

.4

B ur ie d w at er li ne A ss um ed d ep th

.0

.0

B ur ie d te le ph on e A ss um ed d ep th

.0

.7

B ur ie d w at er li ne A ss um ed d ep th

.0

.8

B ur ie d w at er li ne A ss um ed d ep th

.0

Original ground surface

Cl. CR1

PLAN

0 100'50'

PROFILE

Note: Vertical Scale Exaggerated 5x For Clarity

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER -

K. WHITESELL

K. KEARNS

B. ZOOK

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 3-

LA

S T

S A V

ED

B Y

K W

H

IT

ES

EL

L

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

PLAN AND PROFILE

3011+00 TO 3022+00

DENVER, CO

382-D-60620

TECH. APPR.

APPROVED

PEER REVIEWER -

TECH. APPR.

APPROVED

PEER REVIEWER -

Orpineda, Crystal M P.E.

Steen, Timothy M Supervisor Water Conveyance 2

APPROVED £AT£

FO

Bend 3039+63.27 Δ=11°15'00" N=1,577,862.05 E=3,360,215.18

Bend 3040+13.69 Δ=2°59'29" N=1,577,859.05 E=3,360,265.51

Cl. CR1 Reach

Estimated excavation limits

Edge of road

Estimated excavation

Cl. CR1

CDOT

ROW

Private Drive, see Note 1

SRA Area, see Specifications

Proposed permanent easement

Proposed construction easement

Proposed fiber optic pull box

.4

0'17

.3

95.5' 55'

S.H. 96

M A

TC

H

LIN

E 3033+

AT

C H

L

4+

Fence crossing, see Note 2

Estimated clearing and grubbing limits

22.8'

45.4'

EL

EV

A

TI

O N

STATION

3033+00 3034+00 3036+00 3038+00 3040+00 3042+00 3044+00

.0

-0 °1

6'

S=0.00590

Standard trench 36B350

H G

L

2.

H G

L

7.

El. 4440.98 El. 4446.00El. 4445.70

S=0.00590S=0.00590S=0.00590

S=0.00100

Ed ge o f ro ad

Ed ge o f ro ad

.4

B ur ie d te le ph on e To p

.7

Original ground surface

Cl. CR1

.9

Fe nc e cr os si ng

.0

Fe nc e cr os si ng

OPEN-CUT ROAD CROSSINGS

Station

Surfacing Start End

3037+92 3038+43 Gravel

PROFILE

Note: Vertical scale exaggerated 5x for clarity

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER -

K. WHITESELL

K. KEARNS

B. ZOOK

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 3-

LA

S T

S A V

ED

B Y

K W

H

IT

ES

EL

L

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

PLAN AND PROFILE

3033+00 TO 3044+00

DENVER, CO

382-D-60622

PLAN

0 100'50'

1. See Note 14 on (60614) and Specifications for access requirements while trenching through private drives.

2. Remove and replace fence disturbed by construction activities in accordance with the Specifications.

NOTES TECH. APPR.

APPROVED

PEER REVIEWER -

TECH. APPR.

APPROVED

PEER REVIEWER -

Orpineda, Crystal M P.E.

Steen, Timothy M Supervisor Water Conveyance 2

APPROVED £AT£

FO

FO

3053+72.85 1°30'13"

N=1,577,707.36 E=3,361,616.18

Bend 3055+50.87 Δ=4°08'24" N=1,577,692.14 E=3,361,793.54

Bend 3057+54.01 Δ=4°52'15" N=1,577,660.20 E=3,361,994.16

Bend 3059+23.99 Δ=11°15'00" N=1,577,619.32 E=3,362,159.15

Bend 3061+28.51 Δ=5°00'00" N=1,577,532.36 E=3,362,344.26 Bend

3063+10.15 Δ=4°59'44" N=1,577,441.08 E=3,362,501.30

Bend 3065+09.37 Δ=4°42'16" N=1,577,326.36 E=3,362,664.17

Bend 3067+02.21 Δ=0°55'21" N=1,577,202.75 E=3,362,812.19

Estimated excavation limits

Cl. CR1

Edge of road

CDOT ROW

Proposed construction easement

Proposed fiber optic pull box

.8

0'

.3

6.

9'

S.H. 96

B oo ne d.

C H

L

5+

CH

L

Estimated clearing and grubbing limitT21S, R61W

, SEC 9

T21S, R61W

, SEC 8

T21S, R61W, SEC 5

T21S, R61W, SEC 8

T21S, R61W

, SEC 4

T21S, R61W

, SEC 5

T21S, R61W, SEC 4

T21S, R61W, SEC 9

EL

EV

A

TI

O N

STATION

3055+00 3056+00 3058+00 3060+00 3062+00 3064+00 3066+00

S=-0.02850

.0

-1 °3

4'

.0

1°

'1 4"

H G

L

7.

H G

L

4.

S=-0.00100

S=-0.00341

El. 4445.90

El. 4438.34

El. 4445.40

El. 4439.70

Standard Trench 36B350

Original ground surface

Cl. CR1

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER -

K. WHITESELL

K. KEARNS

B. ZOOK

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 3-

LA

S T

S A V

ED

B Y

K W

H

IT

ES

EL

L

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

C T

A R K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

PLAN AND PROFILE

3055+00 TO 3066+00

DENVER, CO

382-D-60624

PROFILE

Note: Vertical Scale Exaggerated 5x For Clarity

PLAN

0 100'50'

NOTES

1. Estimated clearing and grubbing limits are defined from edge of road to line shown.

TECH. APPR.

APPROVED

PEER REVIEWER -

TECH. APPR.

APPROVED

PEER REVIEWER -

Orpineda, Crystal M P.E.

Steen, Timothy M Supervisor Water Conveyance 2

APPROVED £AT£

A

TI

O N

STATION

3066+00 3068+00 3070+00 3072+00 3074+00 3076+00 3077+00

S=-0.00341

Standard Trench 36B350

H G

L

4.

H G

L

8.

El. 4438.34

El. 4434.59

Original ground surface

Cl. CR1

FO FO

Bend 3067+02.21 Δ=0°55'21" N=1,577,202.75 E=3,362,812.19

Bend 3074+36.35 Δ=1°41'00" N=1,576,723.17 E=3,363,368.02 Bend

3076+38.15 Δ=2°38'41" N=1,576,595.88 E=3,363,524.62

Cl. CR1

Edge of road

Estimated excavation limits

CDOT ROW

Proposed construction easement

Proposed fiber pull box

Proposed fiber optic pull box

0'17

.6

.2

S.H. 96

TC

H L

6+

TC

H L

7+ grubbing limit

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER -

K. WHITESELL

K. KEARNS

B. ZOOK

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 3-

LA

S T

S A V

ED

B Y

K W

H

IT

ES

EL

L

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

C T

A R K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

PLAN AND PROFILE

3066+00 TO 3077+00

DENVER, CO

382-D-60625

PROFILE

Note: Vertical Scale Exaggerated 5x For Clarity

PLAN

0 100'50'

NOTES

1. Estimated clearing and grubbing limits are defined from edge of road to line shown.

TECH. APPR.

APPROVED

PEER REVIEWER -

TECH. APPR.

APPROVED

PEER REVIEWER -

Orpineda, Crystal M P.E.

Steen, Timothy M Supervisor Water Conveyance 2

APPROVED £AT£

A

TI

O N

STATION

3077+00 3078+00 3080+00 3082+00 3084+00 3086+00 3088+00

.0

0°

'3 3"

Standard Trench

36B350

H G

L

8.

H G

L

0.

El. 4434.59

El. 4432.65

S=0.00112 B lo w of f w ith m an ho le

Ed ge o f ro ad

Ed ge o f ro ad

El. 4432.20

S=-0.00341

Original ground surface

Cl. CR1

OPEN-CUT ROAD CROSSINGS

Station

Surfacing Start End

3079+17 3079+33 Gravel

FO

44444446

Bend 3078+62.05 Δ=2°19'25" N=1,576,462.83 E=3,363,704.70

Estimated excavation limits

Cl. CR1

Edge of road

CDOT ROW

Private drive, See Note 1 Proposed construction easement

Proposed fiber optic pull box

0'

.7

.1

TC

H L

8+

TC

H L

7+ grubbing limit

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER -

K. WHITESELL

K. KEARNS

B. ZOOK

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 3-

LA

S T

S A V

ED

B Y

K W

H

IT

ES

EL

L

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

C T

A R K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

PLAN AND PROFILE

3077+00 TO 3088+00

DENVER, CO

382-D-60626

PROFILE

Note: Vertical Scale Exaggerated 5x For Clarity

PLAN

0 100'50'

1. See Note 14 on (60614) and Specifications for access requirements while trenching through private drives.

2. Estimated clearing and grubbing limits are defined from edge of road to line shown

NOTES

TECH. APPR.

APPROVED

PEER REVIEWER -

TECH. APPR.

APPROVED

PEER REVIEWER -

Orpineda, Crystal M P.E.

Steen, Timothy M Supervisor Water Conveyance 2

APPROVED £AT£

A

TI

O N

STATION

3088+00 3090+00 3092+00 3094+00 3096+00 3098+00 3099+00

S=0.00112 S=0.01397

H ea d

0.

El. 4433.40 El. 4436.80

.0

0°

'1 0"

.4

-0 °4

1'

Standard Trench 36B350

H G

L

5.

El. 4432.65

Fused joints required

H G

L

9.

Original ground surface

Cl. CR1

El. 4437.14

FO

Combined miter bend 3097+18.44 Δ=11°15'00" N=1,575,456.37 E=3,365,262.93

Bend 3090+07.46 Δ=0°59'19" N=1,575,820.06 E=3,364,652.76

Bend 3093+76.14 Δ=4°52'55" N=1,575,618.47 E=3,364,961.44

Cl. CR1

Estimated excavation limits

Edge of road

CDOT ROW

Proposed construction easement

Proposed fiber optic pull box

.2

.3

0'

.8

.7

TC

H L

8+

ATC

H

LIN

E 3099+

Fence disturbance, see Note 1

Estimated clearing and grubbing limit

T21S, R61W

, N.E. 1/4SEC 9

T21S, R61W , N.W

. 1/4SEC 9

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER -

K. WHITESELL

K. KEARNS

B. ZOOK

Orpineda, Crystal M

Steen, Timothy M

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

5.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 8-

LA

S T

S A V

ED

B Y

K K

EA

R N

S

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

C T

A R K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

PLAN AND PROFILE

3088+00 TO 3099+00

DENVER, CO

382-D-60627

2025-08-27

PROFILE

Note: Vertical Scale Exaggerated 5x For Clarity

PLAN

0 100'50'

1. Remove and replace fence disturbed by construction activities in accordance with the Specifications.

2. Estimated clearing and grubbing limits are defined by edge of road to line shown

NOTES tal M

R -R -R - Supervisor Water Conveyan

APPROVED £AT£

£RA£Z

oo k, B ri an

P P

.E

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

£TT£

£AT£

£AA£

£TA£

D. GESUNDHEIT

K. KEARNS

T. SHARP

NOTES

1. For air valve details, see (60647) - (60650).

2. For blowoff details, see (60652) and (60653).

AIR VALVE DATA TABLE CR1

Station Head (ft) Air Valve Size (in)

Air Valve Seat Rating

(psi)

PI Elevation (ft)

Ground Surface

Elevation (ft)

Access Mannhole

AWWA Class*

Miter (Yes/No)

Pressure Gage

(Yes/No)

Butterfly Valve AWWA

Class

3009+22.00*** 350 4 144 4,454.45 4,464.0 300 No Yes 250B 3031+00.00 375 4 150 4,439.84 4,450.0 300 No Yes 250B 3031+42.00 350 4 150 4,440.09 4,450.1 N/A No Yes 250B 3049+00.00 350 4 147 4,446.50 4,456.0 N/A No Yes 250B

3109+81.84*** 350 4 146 4,445.80 4,455.3 N/A Yes Yes 250B 3156+42.00*** 375 4 154 4,432.45 4,442.0 N/A No Yes 250B 3164+84.42*** 375 4 155 4,433.50 4,443.9 N/A No Yes 250B 3255+25.00*** 400 4 164 4,412.50 4,422.0 N/A No Yes 250B 3277+25.00*** 400 4 169 4,400.03 4,409.9 300 No Yes 250B

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

5.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 9-

LA

S T

S A V

ED

B Y

K K

EA

R N

S

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

C T

A R K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

TABLES

AIR VALVE AND

BLOWOFF DATA TABLES

DENVER, CO

382-D-60646

BLOWOFF DATA TABLE CR1

Station Head (ft) Line Pipe ID (in)

Blowoff Diameter (in)

Ball Valve Rating

Access Manhole

AWWA Class

Orifice Plate No. Holes**

Pipe Cl.

Elevation (ft)

Ground Surface

Elevation (ft)

Depth of Cover +/- (ft) Manhole?

3000+10.00*** 350 30 6 CLASS 250 250 N/A 4,450.68 4,460.4 8.4 Yes 3031+32.00 375 30 6 CLASS 250 250 N/A 4,440.03 4,450.0 8.7 Yes 3084+00.00 375 30 6 CLASS 250 250 N/A 4,432.20 4,441.8 8.3 Yes

3156+00.00*** 375 30 6 CLASS 250 250 N/A 4,432.40 4,442.0 8.3 Yes 3156+32.00*** 375 30 6 CLASS 250 250 N/A 4,432.44 4,442.0 8.2 Yes 3246+75.00*** 400 30 6 CLASS 250 250 31 4,406.20 4,416.0 8.5 Yes 3276+93.00*** 400 30 6 CLASS 250 250 31 4,400.05 4,409.9 8.5 Yes

* N/A No manhole *** Requires structural excavation

** N/A No orifice plate *** Requires structural excavation

APPROVED

PEER REVIEWER

£AT£

TYPICAL SECTION - BLOWOFF WITH MANHOLE ASSEMBLY

M NOT TO SCALE

8"

Ball valve, see Blowoff Table (60646) for size

Cl. 72" manhole

Original ground surface

Coarse aggregate

PI El.

see (60646)

Top of pipe embedment

3'-0" min.**

HDPE pipe Blowoff Valve Assembly

*L as required.

**Offset 3'-0" when located at bends. Offset on side of station and elevation with flatter slope.

***5'-0" min. for non-mitered bends. Extend/end at bend joint for miter bends.

5'-0"*** 5'-0"***

6"

1'-3"

9" m in

Cl. line Pipe

L*

1'-9"

See (60654) for slab dimensions

3.0' min.

12.0' min.

Slope for safety, typ.

1' -0 m in ty p

1.5' typ.

Manhole frame and cover not shown

Manhole rungs not shown, see (60654)

Compacted backfill

Restore surface to original ground conditions

Std. steel pipe size to match blowoff, see Detail 12

Insulation not shown

4" spray-on insulation, see Notes

Cl. 24" I.D. HDPE pipe access, Type B, see Notes for pressure class 6" typ.

12" traffic rated manhole frame and cover for fire hose connection, see Detail 15

Cl. Blowoff valve

Actuator, see Notes

Structural excavation, if required

ID

4" spray-on insulation, see Notes

Operator for ball valve shall extend out beyond insulation cover

Compacted backfill

Orifice Plate, see Detail 13

Cl. Manhole and valve

Top of pipe embedment

TYPICAL SECTION - BLOWOFF WITH MANHOLE ASSEMBLY

L NOT TO SCALE

Cl. 24" ID HDPE access pipe, Type B, see Notes for pressure class

Ball valve

Std. steel pipe size to match blowoff

Restore surface to original ground conditions

L*

Cover blowoff and manhole with insulation jacket

Insulation shall not inhibit movement or operation of valve

HDPE to steel flanged connection

3.0' min.

12.0' min.

Manhole frame and cover not shown

*L as required

Top of pipe embedment

Bedding and embedment

Operator for ball valve shall extend out beyond insulation cover

Structural excavation, if required

Cl. pipe

M

L

Spray-on insulation

72" Manhole vault, see (60654) for details

24" ID access to pipe

12" traffic rated manhole frame and cover

24" ID access to surface

Flow

6-inch Fire hose adaptor

42" Long, 6" Std. steel pipe with threaded end

Flanged connection

See Detail 12

90° Threaded iron elbow

Note: This is a separate attachment to replace blind flange when draining is required. Store with valve in vault/manhole.

Standard steel pipe size to match blowoff

Blind flange, size to match blowoff valve

See Detail 13 for Orifice Plate Detail

3/

4"

Stainless steel. Plate to mate with AWWA flange.

TYPICAL DETAIL - ORIFICE PLATES

13 NOT TO SCALE

Ø1/2", typ.

3/4", typ.

1/8"

N

Holes in an array of equilateral triangles with 3/4" legs, see Blowoff Data Table (60646) and Sectionalizing Valve Data Table (60657/60658) for number of holes

Exploded view Anchor barb

3"

18" min.

Carsonite utility marker with anchor barb, or equal

Utility line marker

Anchor barb

1.5"

1 "

Flow

TYPICAL SECTION - ORIFICE PLATE

N NOT TO SCALE

TYPICAL DETAIL - ORIFICE PLATE HOLES

14 NOT TO SCALE

The upstream holes to be rounded with R=1/4" fillets

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

£TT£

£AT£

£AA£

£TA£

D. GESUNDHEIT

K. KEARNS

T. SHARP

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

5.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 9-

LA

S T

S A V

ED

B Y

K K

EA

R N

S

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

C T

A R K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

PLAN, SECTIONS,

AND DETAILS

BLOWOFF WITH

MANHOLE ASSEMBLY

(HDPE) AND UTILITY

DENVER, CO

382-D-60652

PLAN - BLOWOFF W/ PIPE ACCESS HDPE

NOT TO SCALE

FIRE HOSE CONNECTION DETAIL

11 NOT TO SCALE

DETAIL - SPOOL

12 NOT TO SCALE

GENERAL BLOWOFF NOTES

1. For Blowoff Data Table, see (60646).

2. For blowoff detail drawings, see (60652/60653).

3. For coating and lining requirements for Std. steel pipe and fittings, see Specifications.

4. See Blowoff Data Table (60646), for Ball Valve AWWA class designation.

5. All welds to be completed prior to lining application.

6. Extend spray-on insulation a minimum of 36" below finish grade.

Limit spray-on insulation near manhole rungs, see (60654).

Insulation shall not impede the use of the manhole rungs.

7. Place one utility marker stake for each bend, blowoff valve, air valve, and sectionalizing valve assembly, and two per road crossing installed 1.0' from ROW fence.

8. Water main utility marker stakes shall be blue, and 66" in length.

9. Orient actuator such that 24" minimum clearance is provided for operation of the hand wheel. Hand wheel not shown, see Specifications for information.

DETAIL - UTILITY MARKER STAKE

APPROVED

PEER REVIEWER

TYPICAL SECTION - BLOWOFF WITH MANHOLE ASSEMBLY

O NOT TO SCALE

8"

Insulation not shown

Ball valve, see Blowoff Table (60646) for size

Std. steel pipe size to match blowoff, see Detail 12 (60652)

Cl. 72" manhole

Original ground surface

4" spray-on insulation, see Notes

Coarse aggregate

PI Elev.

see (60646)

1.0' typ.

Top of pipe embedment

3'-0" Min.**

1' m in

Steel pipe blowoff valve assembly

*L as required.

**Offset 3'-0" when located at bends. Offset on side of station and elevation with flatter slope.

***5'-0" min. for non-mitered bends. Extend/end at bend joint for miter bends.

5'-0"*** 5'-0"***

Cl. 24" ID steel pipe access, Type B, see Notes for pressure class

6"

1'-3"

9" m in

Cl. line pipe

Restore surface to original ground conditions

L*

6" typ.

1'-9"

Joint to suit line pipe

See (60654) for slab dimensions

3.0' min.

12.0' min.

Joint to suit line pipe

Manhole frame and cover not shown

Manhole rungs not shown, see (60654)

Slope for safety, typ.

Compacted backfill

12" traffic rated manhole frame and cover for fire hose connection, see Detail 11 (60652)

Cl. Blowoff valve

Actuator, see Notes

Structural excavation, if required

Ball valve

ID

4" spray-on insulation, see Notes

Operator for ball valve shall extend out beyond insulation cover

Orifice Plate see Detail (60652)

Cl. Manhole and valve

TYPICAL SECTION - BLOWOFF WITH MANHOLE ASSEMBLY

P NOT TO SCALE

Cl. 24" pipe access, Type B, see 40-D-6137, see Notes for pressure class

Std. steel pipe size to match blowoff

Restore surface to original ground conditions

L*

Cover blowoff and manhole with insulation jacket

3.0' min.

12.0' min.

Top of pipe embedmentID dimension to the inside of the lining, see specifications.

Manhole frame and cover not shown

*L as required.

Insulation shall not inhibit movement or operation of valve

Compacted backfill

Structural excavation, if required

Cl. pipe

P

Spray-on insulation

72" manhole, see (60654) for details

O

24" ID access to pipe

12" traffic rated manhole frame and cover

24" ID access to surface

Flow

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

£TT£

£AT£

£AA£

£TA£

D. GESUNDHEIT

K. KEARNS

T. SHARP

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

5.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 9-

LA

S T

S A V

ED

B Y

K K

EA

R N

S

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

C T

A R K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

PLAN, SECTIONS,

AND DETAILS

BLOWOFF WITH

MANHOLE ASSEMBLY

(PVC)

DENVER, CO

382-D-60653

PLAN - BLOWOFF W/ PIPE ACCESS PVC

NOT TO SCALE

NOTE

1. For general Blowoff With Manhole

Assembly Notes see (60652).

APPROVED

PEER REVIEWER

Cv

WW

D

Original ground surface

Miter bend

DETAIL - MITER RESTRAINED JOINT PIPE

16 NOT TO SCALE

All joints shall be restrained

Fitting No.2

Fitting No. 1

W2 x2

W1

W1 mod=W1 + x2

W2=W2

W 1&2

Calculating overlapping restraint lengths:

1. W1= Calculated restraint length for fitting No.1 (W value as shown in table).

2. W2= Calculated restraint length for fitting No.2 (W value as shown in table).

3. x2=Overlapping distance between fittings.

4. W1,W2= Length of pipe requiring restrained joints.

5. W1&2= Restrain all joints between fittings 1 and 2.

6. Fitting = Bend, Sectionalizing Valve, etc., requiring restraint length.

Fitting No.2

Fitting No. 1

W2

W1=W1 W1&2

W2=W2

Main Line Pipe

Main Line Pipe

DETAIL - ADJOINING FITTINGS RESTRAINT OVERLAP

19 NOT TO SCALE

DETAIL - RESTRAINT OVERLAP WITH ADJACENT FITTING

18 NOT TO SCALE

W1

W1 W1

D

Miter bend

DETAIL - MITER JOINT

17 NOT TO SCALE

R

W2

W1

Restrained joints per CR1 Bend Restrained Lengths Tables

CR1 BEND RESTRAINED LENGTHS

Station Head

(ft) Defection Angle Type of Bend Miter

(Yes/No) Line Pipe ID

(in) Cover (ft) W (ft) Centerline El. (ft)

Ground El. (ft)

3000+10.00 350 1°29'49'' Convex Down No 30 8.4 N/A 4,450.68 4,460.4 3000+50.00 350 0°32'22'' Horizontal No 30 8.2 N/A 4,450.85 4,460.4 3004+68.83 350 0°31'24'' Horizontal No 30 8.3 N/A 4,452.57 4,462.2 3007+92.31 350 2°37'13'' Horizontal No 30 7.0 N/A 4,453.91 4,462.2 3008+85.07 350 4°20'54'' Horizontal No 30 7.9 N/A 4,454.29 4,463.5 3030+81.80 375 11°15'00'' Horizontal Yes 30 8.9 5 4,439.74 4,450.0 3039+63.27 350 11°15'00'' Horizontal Yes 30 7.3 6 4,444.90 4,453.5 3040+13.69 350 2°59'29'' Horizontal No 30 7.1 N/A 4,445.19 4,453.6 3041+00.00 350 0°16'51'' Convex Up No 30 6.6 N/A 4,445.70 4,453.6 3049+00.00 350 0°06'53'' Convex Up No 30 8.2 N/A 4,446.50 4,456.0 3053+72.85 350 1°30'13'' Horizontal No 30 8.4 N/A 4,446.03 4,455.8 3055+50.86 350 4°08'24'' Horizontal No 30 8.7 N/A 4,445.85 4,455.9 3057+54.01 350 4°52'16'' Horizontal No 30 8.6 N/A 4,445.65 4,455.6 3059+23.99 350 11°15'00'' Horizontal Yes 30 7.0 6 4,445.48 4,453.8 3060+00.00 350 1°34'31'' Convex Up No 30 5.3 N/A 4,445.40 4,452.0 3061+28.51 350 5°00'00'' Horizontal No 30 6.8 N/A 4,441.74 4,449.9 3062+00.00 375 1°26'14'' Convex Down No 30 7.0 N/A 4,439.70 4,448.0 3063+10.15 375 4°59'44'' Horizontal No 30 7.3 N/A 4,439.32 4,448.0 3065+09.36 375 4°42'16'' Horizontal No 30 6.0 N/A 4,438.65 4,446.0 3067+02.21 375 0°55'21'' Horizontal No 30 6.6 N/A 4,437.99 4,445.9 3074+36.35 375 1°41'00'' Horizontal No 30 7.2 N/A 4,435.49 4,444.0 3076+38.15 375 2°38'42'' Horizontal No 30 7.9 N/A 4,434.80 4,444.0 3078+62.05 375 2°19'25'' Horizontal No 30 8.0 N/A 4,434.03 4,443.4 3084+00.00 375 0°15'33'' Convex Down No 30 8.3 N/A 4,432.20 4,441.8 3090+07.46 375 0°59'19'' Horizontal No 30 5.8 N/A 4,432.88 4,440.0 3093+76.14 375 4°52'55'' Horizontal No 30 5.6 N/A 4,433.29 4,440.2 3094+75.00 375 0°47'07'' Convex Down No 30 7.1 N/A 4,433.40 4,441.8 3097+18.44 375 11°16'15'' Combined Yes 30 6.5 7 4,436.80 4,444.6 3099+94.43 375 22°30'00'' Horizontal Yes 30 9.3 10 4,437.32 4,448.0 3106+64.42 375 90°00'00'' Horizontal Yes 30 8.8 51 4,438.60 4,448.7 3108+30.36 375 2°54'11'' Horizontal Yes 30 10.4 2 4,438.91 4,450.6 3108+76.50 375 45°06'33'' Combined Yes 30 11.1 17 4,439.00 4,451.4 3109+28.35 350 22°30'00'' Horizontal Yes 30 10.3 12 4,442.34 4,454.0 3109+81.84 350 4°47'28'' Combined Yes 30 8.2 4 4,445.80 4,455.3 3112+73.38 350 11°15'00'' Horizontal Yes 30 9.4 5 4,445.31 4,456.0 3113+39.55 350 11°15'00'' Horizontal Yes 30 8.1 5 4,445.20 4,454.6 3114+00.00 350 0°02'05'' Convex Up No 30 7.4 N/A 4,445.10 4,453.8 3114+39.55 350 4°06'05'' Horizontal No 30 7.4 N/A 4,445.01 4,453.7 3116+13.15 350 2°08'29'' Horizontal No 30 6.1 N/A 4,444.61 4,452.0 3117+31.06 350 45°00'00'' Horizontal Yes 30 6.3 32 4,444.35 4,452.0 3118+20.07 350 45°00'00'' Horizontal Yes 30 6.5 31 4,444.14 4,452.0 3120+07.13 350 1°30'00'' Horizontal No 30 6.9 N/A 4,443.72 4,452.0 3127+49.46 350 0°56'30'' Horizontal No 30 6.6 N/A 4,442.03 4,450.0 3132+00.00 350 0°36'51'' Convex Up No 30 6.0 N/A 4,441.00 4,448.3 3135+00.00 375 0°32'60'' Convex Down No 30 5.6 N/A 4,437.10 4,444.0 3145+00.00 375 0°07'38'' Convex Down No 30 6.6 N/A 4,433.70 4,441.6 3156+00.00 375 0°08'20'' Convex Down No 30 8.3 N/A 4,432.40 4,442.0 3164+84.42 375 3°46'08'' Combined No 30 9.1 N/A 4,433.50 4,443.9 3166+03.00 375 3°52'17'' Horizontal No 30 7.4 N/A 4,433.33 4,442.1 3180+00.00 375 0°01'19'' Convex Down No 30 6.9 N/A 4,431.30 4,439.5 3184+61.91 375 0°12'07'' Horizontal No 30 9.8 N/A 4,430.81 4,441.9 3195+00.00 375 0°01'44'' Convex Up No 30 7.0 N/A 4,429.70 4,438.0 3202+00.00 375 0°22'33'' Convex Up No 30 6.1 N/A 4,428.60 4,436.0 3206+07.55 375 4°27'42'' Horizontal No 30 7.4 N/A 4,425.29 4,434.0 3212+07.55 375 0°32'40'' Horizontal No 30 6.3 N/A 4,420.41 4,428.0 3225+00.00 400 0°21'04'' Convex Down No 30 6.8 N/A 4,409.90 4,418.0 3236+07.69 400 0°24'56'' Horizontal No 30 7.0 N/A 4,407.68 4,416.0 3239+50.00 400 0°03'05'' Convex Down No 30 5.7 N/A 4,407.00 4,414.0 3246+75.00 400 0°50'42'' Convex Down No 30 8.5 N/A 4,406.20 4,416.0

AL

W

AY

S

TH

IN

K

SA

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

5.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 8-

LA

S T

S A V

ED

B Y

K K

EA

R N

S

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

C T

A R K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

DETAILS

MITER BEND THRUST

RESTRAINT TABLE

DENVER, CO

382-D-60655

2025-08-27

NOTES

1. All miter bends shall have restrained joint connections.

2. See Specifications for limitations concerning "W" length and the different pipe material type options.

3. All joints within calculated restrained length "W" must be restrained. If the distance between fittings is less than or equal to the calculated restrained length, see Details 18 and 19.

4. All joints are to be restrained under wash crossings and in casings.

5. Joints shall be restrained when on slopes greater than 20%.

6. A fused HDPE joint or connection meets the intent of the restrained joints listed above.

7. Bends between Stations 3009+35.00 and 3029+80.00 are part of the

HDD and are not included in CR1 Restrained Bend Tables.

8. A mitered bend includes 2 miters or more.

9. Radius of bend must be a minimum of 2D.

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER -

D. GESUNDHEIT

D. GESUNDHEIT

K. KEARNS

Orpineda, Crystal M P.E.

Steen, Timothy M

CR1 BEND RESTRAINED LENGTHS (CONTINUED)

Station Head

(ft) Defection Angle Type of Bend

Miter (Yes/No)

Line Pipe ID

(in) Cover (ft) W (ft)

Centerline El. (ft)

Ground El. (ft)

3251+00.00 400 0°42'52'' Convex Up No 30 6.7 N/A 4,412.00 4,420.0

3254+86.24 400 2°58'26'' Horizontal No 30 8.2 N/A 4,412.45 4,422.0

3255+25.00 400 0°07'41'' Convex Up No 30 8.2 N/A 4,412.50 4,422.0

3256+06.58 400 2°05'03'' Horizontal No 30 8.3 N/A 4,412.41 4,422.0

3258+78.47 400 0°45'38'' Horizontal No 30 8.5 N/A 4,412.13 4,422.0

3260+35.11 400 11°15'00'' Horizontal Yes 30 8.7 7 4,411.96 4,422.0

3261+20.11 400 11°15'00'' Horizontal Yes 30 8.7 7 4,411.87 4,421.9

3263+75.00 400 0°21'43'' Convex Up No 30 7.1 N/A 4,411.60 4,420.0

3267+20.16 400 0°35'57'' Horizontal No 30 5.6 N/A 4,409.05 4,416.0

3271+75.00 400 0°22'19'' Convex Up No 30 6.1 N/A 4,405.70 4,413.1

3275+50.00 400 0°38'22'' Convex Down No 30 8.2 N/A 4,400.50 4,410.0

APPROVED

PEER REVIEWER

Air Valve or Blowoff Valve Assembly, see Notes

S S

T

T

U

U

Cl. pipe

Compacted backfill, see (60654) for extents

Line pipe

Line pipe

Original ground surface

Sectionalizing valve Station

4" valve box and sleeve

Butterfly valve, see Sectionalizing Valve Data Table for size.

6" butterfly valve with 4" valve box and sleeve

72" Diameter precast concrete manhole

Air Valve or Blowoff Valve Assembly, see Notes

Sectionalizing valve station

Steel pipe

10'-0"

Valve box and sleeve

CLSM

10'-0"

P.I.

P.I.

P.I.P.I.

See Detail 19

Structural excavation, see Sectionalizing Valve Data Table for depth of over excavation required.

4.0'

HDPE to steel flanged joint, typ.

Steel to HDPE flanged joint, typ.

Cl. 72" Diameter precast concrete manhole, see (60654)

Sampling Tap connection as indicated on the Plan and Profiles, see Note 3. See (60660) for station locations. 22'-0" 10'-0"

Sleeve type coupling, flexible type, with AWWA M11 harness, typ.

Sleeve type coupling, flexible type with AWWA M11 harness, typ.

Slope for safety, typ.

Compacted backfill, see Specifications

HDPE to steel flanged joint, typ.

Compacted backfill, see (60654) for extents

Compacted backfill, see Specifications

Steel pipe

Sampling Tap connection as indicated on the Plan and Profiles, see Note 3.

See (60660) for station locations.

Butterfly valve

HDPE to steel flanged joint, typ.

Manhole, see (60654)

Flow

Flow

1'-1" 1'-0"

TYPICAL SECTION - BYPASS LINE FROM PIPE

T NOT TO SCALE

5"

Cl. steel pipe

Steel collar per

AWWA M-11

Cl. Grooved-end type coupling

Orifice plate, see (60652)

PI 6", 90° Std.

steel welding elbow

Cl. filling line

6" Std. steel pipe

Flanges

1'-6"

7"

TYPICAL SECTION - BYPASS LINE INTO PIPE

U NOT TO SCALE

Cl. steel pipe

Steel collar per AWWA M-11

Cl. Grooved-end type coupling

PI 6", 90° Std.

steel welding elbow

Cl. filling line

6" Std. steel pipe

DETAIL - VALVE BOX AND SLEEVE

19 NOT TO SCALE

V

1' -0

Original ground surface

Lockable lid, see Specifications

Extend rod to surface

Furnish and install square stem extension

Notch pipe as required to obtain snug and overlapping fit

Square nut operator

Furnish and install square stem extension pin/lock to valve nut

Standard pipe valve box

4- #4 bars, e.w., e.f.

Valve#_

8" Min.

6" m in

Flow Direction 4" BFV Fill Line

DETAIL - NAME PLATE

20 NOT TO SCALE

2" text

Exterior aluminum sign (name plate)

See Note 2

4-1/4" dia. x 1-1/4" zinc plated hammer drive anchors. Install per manufacturer's recommendations.

TYPICAL SECTION - VALVE BOX

V NOT TO SCALE

1'-0" 1'-0"

1' -0

1'

-0

2"

2"

4- #4 e.f.

See Detail 20

4- #4 e.f.

See Note 5

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

£TT£

£AT£

£AA£

£TA£

D. GESUNDHEIT

K. KEARNS

T. SHARP

GENERAL SECTIONALIZING VALVE NOTES

1. For sectionalizing valve details drawings, see (60657/60658).

2. All sectionalizing valves will require a bypass.

3. See Plan and Profile (60619) - (60645) for valve type assembly.

4. See (60647/60648) for air valve details and (60652/60653) for blowoff details.

5. See (40-D-60003 & 40-D-60004) for clear spacing and cover.

TYPICAL SECTION - HDPE SECTIONALIZING VALVE ASSEMBLY

S

NOT TO SCALE

AL

W

AY

S

TH

IN

K

SA

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

5.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 9-

LA

S T

S A V

ED

B Y

K K

EA

R N

S

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

C T

A R K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

DETAILS

TYPICAL

SECTIONALIZING VALVE

ASSEMBLY - HDPE

DENVER, CO

382-D-60657

PLAN - HDPE SECTIONALIZING VALVE ASSEMBLY

NOT TO SCALE

SECTIONALIZING VALVE DATA TABLE CR1

Sectionalizing Valve Station

Valve Size (in)

Valve Head Class (ft)

Orifice Design

Head (ft)

Number Of Orifice Holes For

Bypass Pipe

Depth of Structural Excavation

Required (ft)

3031+22.00 30 325 319.12 14 2

3156+22.00 30 350 326.66 13 3

3277+15.00 30 375 358.97 13 3

Air Valve or Blowoff Valve Assembly, see Notes

Sectionalizing valve concrete collar, see (60659)

W W

1'-8"

T

T

U

U

Cl. pipe

5'-0"

Sectionalizing valve Station

4" valve box and sleeve

Butterfly valve, see Sectionalizing Valve Data Table for size

6" butterfly valve with 4" valve box and sleeve

Air Valve or Blowoff Valve Assembly, see Notes

10'-0"

Sectionalizing valve concrete collar

10'-0"

P.I.

P.I.

Reinforcement not shown, see (60659)

Thrust ring see (60659)

4'-0"

Sampling Tap connection as indicated on the Plan and Profiles, see Note 3. See (60660) for station locations.

15'-0" 10'-0"

Thrust ring

Manhole, see (60654)

5'-0"5'-0"

2'-0"

Flow

Flow

Compacted backfill, see (60654) for extents

Line pipe

Original ground surface

72" Diameter precast concrete manhole

Sectionalizing valve station

Steel pipe

Valve box and sleeve

CLSM

P.I.P.I.

See Detail 19, (60657)

Structural excavation, see Sectionalizing Valve Data Table (60657) for depth of over excavation required.

Cl. 72" Diameter precast concrete manhole, see (60654)

Sleeve type coupling, flexible type, with AWWA M11 harness, typ.

Sleeve type coupling, flexible type with AWWA M11 harness, typ.

Compacted backfill, see (60654) for extents

Compacted backfill, see Specifications

Steel pipe

Sampling Tap connection as indicated on the Plan and Profiles, see Note 3.

See (60660) for station locations.

Butterfly valve

Joint to suit line pipe furnished

Slope for safety, typ.

Joint to suit line pipe furnished

Compacted backfill, see Specifications

Joint to suit line pipe furnished

Joint to suit line pipe furnished

Sleeve type coupling, flexible type with AWWA M11 harness, typ.

Sleeve type coupling, flexible type, with

AWWA M11

harness, typ.

Line pipe

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

£TT£

£AT£

£AA£

£TA£

D. GESUNDHEIT

K. KEARNS

T. SHARP

NOTES

1. See (60657) for General Sectionalizing Valve Notes.

2. See (60652) for General Blow Off Valve Notes.

TYPICAL SECTION - PVC SECTIONALIZING VALVE ASSEMBLY

W

NOT TO SCALE

AL

W

AY

S

TH

IN

K

SA

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

5.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 9-

LA

S T

S A V

ED

B Y

K K

EA

R N

S

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

C T

A R K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

DETAILS

TYPICAL

SECTIONALIZING VALVE

ASSEMBLY - PVC

DENVER, CO

382-D-60658

PLAN - PVC SECTIONALIZING VALVE ASSEMBLY

NOT TO SCALE

V er tic al d im en si on t op V er tic al d im en si on b ot to m

2 Horizontal length 1

2 Horizontal length

D ep th o f bl oc k

Horizontal reinforcement and spacing e.f.

Vertical reinforcement and spacing e.f.

2.0' typ.

Compacted backfill, see Specifications

For Type 2 and 3 materials structural excavation as shown, For Type 1 materials excavate as required for placement directly against in-situ materials.

Original ground surface

X

T

T/2

See Detail 22

Vertical reinforcement and spacing, see CR1 Sectionalizing Valve Collar Table

Select backfill compacted per Specifications

3" clr. typ.

3" c lr ty p.

3" clr., typ.

3" c lr ty p.

#5@1'-0" Tie Bar, typ.

Structural excavation, see Sectionalizing Valve Data Table Crowley Reach 1, see (60658)

#5 Hoop e.f.

Slope for safety, typ.

Structural backfill, see

Specifications

#5@1'-0" Tie bar, typ.

2-#5 hoops

Vertical reinforcement and spacing, see CR1 Sectionalizing Valve Collar Table

Wrapper plate extents

#5@1'-0" Tie bar, typ.

#5@1'-0" Tie bar, typ.Earthwork not shown, see (60658)

DETAIL - THRUST RING (PER AWWA M11)

22 NOT TO SCALE

4"

10" min. 10" min.

3 4"

T/2T/2

3/4" steel wrapper plate

Concrete collar, reinforcement not shown, see Detail

T

1/ 4"

8"x4" Anchor ring

1/ 4"

1/ 4"

1/ 4"

AL

W

AY

S

TH

IN

K

SA

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

5.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

2- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 9-

LA

S T

S A V

ED

B Y

K K

EA

R N

S

¦D_DT¦

¦STATUS¦

FR

YI

N G

PA

N

-A R K A N

S A S P

R O

JE

C T

A R K A N

S A S V

A

LL

EY

C

O N

D U

IT

C R O

W

LE

Y R

EA

C H

DETAILS

TYPICAL CONCRETE

THRUST COLLAR PLAN

AND SECTION

DENVER, CO

382-D-60659

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

£TT£

£AT£

£AA£

£TA£

D. GESUNDHEIT

D. GESUNDHEIT

K. KEARNS

NOTES

1. For general concrete outline notes and for minimum requirements for detailing reinforcement, see 40-D-60003 and 40-D-60004.

2. For coating and lining options, see Specifications.

OPERATING CRITERIA

1. Excavation around blocking shall not occur when the pipe is under any pressure.

SECTION - THRUST COLLAR REINFORCEMENT

X NOT TO SCALE

DETAIL - THRUST COLLAR REINFORCEMENT

21 NOT TO SCALE

CR1 SECTIONALIZING VALVE THRUST COLLAR TABLE

Sectionalizing Valve Station Head (ft) Line Pipe

ID (in) Horizontal length

Vertical dimension top

Vertical dimension bottom T Depth of block (ft) Vertical

Reinforcement Horizontal

Reinforcement

3031+22.00 375 30 12'-0'' 5'-11'' 4'-1'' 1'-6'' 4.1 #5@6'' #5@6'' 3156+22.00 375 30 15'-0'' 6'-8'' 4'-4'' 2'-0'' 2.9 #5@6'' #5@6'' 3277+15.00 400 30 16'-0'' 5'-11'' 4'-1'' 2'-0'' 3.9 #5@6'' #5@6''

APPROVED

PEER REVIEWER

7"

2'-0"

2' -6

3' -6

6"

9" 2'-0" 6"

3"

6" 6"

3"

9" 9"

3" 6"

6" 6"

7"

9" 9"

Varies

1'-0"

Sampling station assembly, similar to Kupferle #66 Bollard

Sampling valve

Drainage valve

7" Bollard enclosure, see Specifications