Attachment 16. NADB IOI Direct Laterals Design.pdf
PDF 13 MB Posted
- Attached to
- Nogales IOI Rehabilitation Phase 4 & 5
- Solicitation number
- 191BWC22R0005
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C B
X
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOIIOIIOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE PLE PLE PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE PLE PLE PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
C
C
C C
C
C
C
WASTEWATER DESIGN OF LATERAL CONNECTIONS TO THE
INTERNATIONAL OUTFALL INTERCEPTOR (IOI) IN NOGALES, ARIZONA
SHEET INDEX
SHEET NO. DESCRIPTION
1 TITLE SHEET AND GENERAL NOTES
2 GENERAL NOTES SHEET 2
3 PLAN AND ABANDONMENT: LATERAL SITE #1 IOI MH #2
4 PLAN AND ABANDONMENT: LATERAL SITE #4 IOI MH #36
5 PLAN AND PROFILE: LATERAL SITE #5 IOI MH #39
6 PLAN AND PROFILE: LATERAL SITE #7 IOI MH #52
7 PLAN AND PROFILE: LATERAL SITE #8 IOI MH #52B
8 DETAILS SHEET 1
9 DETAILS SHEET 2
10 DETAILS SHEET 3
11 LATERAL ABANDONMENT SHEET
LEGEND
VICINITY MAP
PROJECT LOCATION MAP
D C B A Δ
DESIGNED BY:PREPARED BY: 2424 E. Broadway Blvd., Suite 200 Tucson, AZ 85719
(520) 561-6467 ngeneng.com
DRAWN BY:
REVIEWED BY:
JOB. NO.
PROJ. NO.
SHEET
OF
DRAWING NO.
WASTEWATER DESIGN OF LATERAL CONNECTIONS TO THE
INTERNATIONAL OUTFALL INTERCEPTOR (IOI) IN NOGALES, ARIZONA
TITLE SHEET AND GENERAL NOTES
IOI LATERAL LOCATION:Tariq Tariq
Tariq Tariq
William O'Brien
T:\T17-001-2020 Nogales IOI 8 Laterals\AutoCAD\IOI-Laterals 100%.dwg
DATE: 4/22/2021
NOGALES, AZ
SHEET 3
SHEET 4
SHEET 5
SH
EE
T 6
SH
EE
T 7
SITE 1IOI MH #2
SITE 4
IOI MH #36
SITE 5
IOI MH #39
SIT
E 7
IO
I M
H #5
SIT
E 8
IO
I M
H #5 2B
100% DESIGN
IOI IOI PIPELINE ALIGNMENT
PLE IOI PIPELINE EASEMENT
W WATER PIPELINE
FO FIBER OPTIC UTILITY LINE
S EXISTING SEWER MAIN LINE
ROAD CENTERLINE
1' CONTOURS
BUILDING FOOTPRINT
WATER MANHOLE/VALVE
SEWER CLEANOUTC
SEWER MANHOLES
PROPOSED LATERAL PIPELINE
EXISTING LATERAL PIPELINE
DRAINAGE MANHOLE
LIGHT POLE
G
CB
R R
M
FIRE HYDRANT
UNKNOWN VALVE/PIPE
POWER POLE / GUY POLE
ROADWAY SIGN
CIRCULAR CATCH BASIN
GAS VALVE
ELECTRIC METER
RAILROAD CROSSING SIGNAL
BENCHMARK
ALL BENCHMARKS AND ELEVATIONS ARE IN FEET AND REFER TO NAVD88.
HORIZONTAL CONTROL IS BASED ON NAD83, ARIZONA STATE PLANE,
CENTRAL ZONE, INTERNATIONAL FEET.
TOPO SOURCE
SANTA CRUZ COUNTY 2017 LiDAR (NAVD88)
GRAND AVE. W
ESTERN
AVE.
MORLEY AVE.
M
ARIPO
SA RD.
GRAND AVE PROJECT LOCATION
DATA SOURCES
1. REHABILITATION IMPROVEMENTS TRUNKLINE AND INTERNATIONAL OUTFALL
INTERCEPTOR - URS DRAWINGS (2002-2020)
2. CITY OF NOGALES GIS DATABASE (ACCESSED 2020)
3. CITY STAFF FIELD INVESTIGATIONS (SEPTEMBER THRU JANUARY 2021)
IN
TERN
ATIO
N
AL BO
U
N
DARY
NOGALES, ARIZONA
Feet
0 750 1500
1"=750'
I-19
RAILROAD TRACK
EDGE OF RAILROAD ROW
GENERAL NOTES
1. THE OWNER INVESTIGATED 8 LATERAL CONNECTIONS PRESUMED TO BE CONNECTING AT INTERMEDIATE POINTS ALONG THE INTERNATIONAL
OUTFALL INTERCEPTOR (IOI) AND NOT AT STANDARD MANHOLES.
2. THIS PROJECT CONSISTS OF RELOCATING AND ABANDONING SEWER LATERALS AT 5 SITE WITHIN THE CITY OF NOGALES. THE 5 SITES ARE
IDENTIFIED AS SITES 1, 4, 5, 7 AND 8, AND THEIR LOCATIONS ARE SHOWN WITHIN THIS DRAWING SET. SITES 2,3, AND 6 WERE ELIMINATED FROM THIS PROJECT AS FIELD INVESTIGATIONS DEMONSTRATED THAT THE SEWER LATERALS AT THESE SITES ARE NOT CONNECTED TO THE IOI.
3. ALL WORK SHALL BE PERFORMED BY A CONTRACTOR LICENSED BY THE STATE OF ARIZONA AS DETERMINED BY THE ARIZONA REGISTRAR OF
CONTRACTORS (A, A-12, A-14, A-16, CR-80 OR KA).
4. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION REGULATIONS.
5. ALL CONSTRUCTION WORK SHALL CONFORM TO THE MARICOPA COUNTY UNIFORM STANDARD SPECIFICATIONS AND DETAILS FOR PUBLIC WORKS
CONSTRUCTION (MAG-USSDPWC).
6. CONTRACTOR SHALL COMMUNICATE PROJECT CONCERNS, FINDINGS, AND CHANGES WITH THE ENGINEER.
7. CONTRACTOR SHALL FURNISH ALL LABOR, EQUIPMENT, APPLIANCES, AND MATERIALS TO PERFORM AND COMPLETE THE WORK COVERED WITHIN
THIS PLAN SET.
8. EXISTING TOPOGRAPHY, PLANS, AND DETAILS REPRESENT EXISTING CONDITIONS TO THE BEST OF THE CITY OF NOGALES AND ENGINEER'S
KNOWLEDGE; HOWEVER, ACTUAL CONDITIONS MAY VARY FROM DRAWINGS.
8.1. ALL DIMENSIONS AND CONDITIONS INDICATED RELATIVE TO EXISTING CONSTRUCTION ARE APPROXIMATES BASED ON AVAILABLE
INFORMATION AND LIMITED FIELD VERIFICATION.
8.2. THE CITY OF NOGALES AND ENGINEER DO NOT GUARANTEE THE LOCATION AND ELEVATION OF SEWER LINES OR OTHER EXISTING
UNDERGROUND STRUCTURES OR OF PROPERTY LINES TO BE EXACT. NOR IS IT WARRANTED THAT ALL EXISTING UNDERGROUND PIPES OR
STRUCTURES ARE SHOWN ON PLANS.
8.3. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, DIMENSIONS, AND ELEVATIONS. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER OF DISCREPANCIES IN THE DRAWINGS, DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS, AND CHANGES IN THE EXISTING AS-BUILT CONDITIONS IF THESE CONDITIONS IMPACTS CONSTRUCTION TIME, LABOR, OR MATERIAL COSTS.
8.4. OMISSION OR CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE DRAWING NOTES AND DETAILS SHALL BE BROUGHT TO THE ATTENTION OF
THE ENGINEER AND RESOLVED BEFORE PROCEEDING WITH THE WORK.
8.5. ELEVATIONS ARE SUBJECT TO FIELD VERIFICATION TO MEET ACTUAL FIELD CONDITIONS. CONTRACTOR TO LOCATE, PROTECT, AND MAINTAIN BENCHMARKS, MONUMENTS, CONTROL POINTS, AND PROJECT ENGINEERING REFERENCE POINTS, RE-ESTABLISH DISTURBED OR DESTROYED ITEMS BY A SURVEYOR REGISTERED IN THE STATE OF ARIZONA, AT NO ADDITIONAL COST TO THE CITY OF NOGALES OR ENGINEER.
9. CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH ALL SITES AND ITEMS OF WORK. LACK OF UNDERSTANDING OF WORK REQUIREMENTS OR
COMPLEXITY SHALL NOT BE CAUSE FOR ADDITIONAL COMPENSATION.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND PAYING FOR ALL APPLICABLE CITY, COUNTY, STATE, AND FEDERAL PERMITS.
CONTRACTOR SHALL PAY ALL COST FOR AND RESPONSIBILITIES ATTACHED THERETO AND ANY REPERCUSSIONS OF NOT FOLLOWING SAID PERMITS AND PROJECT REQUIREMENTS. CONTRACTOR TO ASSURE HIMSELF THAT ALL CONSTRUCTION PERMITS HAVE BEEN OBTAINED PRIOR TO
COMMENCEMENT OF WORK.
11. THIS SET OF CONSTRUCTION DOCUMENTS SHALL BE CONSIDERED AS A WHOLE AND THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS ARE RESPONSIBLE FOR THE INFORMATION PRESENTED ON ALL SHEETS ON THIS SET OF DRAWINGS AND ALL SECTIONS OF THE SPECIFICATIONS.
12. STREETS SHALL BE MAINTAINED FREE AND UNOBSTRUCTED AT ALL TIMES EXCEPT WHERE NOTED. WHERE REQUIRED, FURNISH AND INSTALL BARRICADES AND OTHER PROTECTIVE ENCLOSURES TO SEPARATE AND PROTECT VEHICULAR AND PEDESTRIAN TRAFFIC FROM DEBRIS AND
OTHER DEMOLITION/CONSTRUCTION ACTIVITIES.
13. THE AREAS UTILIZED AS CONTRACTOR'S OFFICE, PARKING, LAY DOWN, STORAGE, AND HAUL ROUTES, ARE TO BE RESTORED TO THE ORIGINAL CONDITION AT THE COMPLETION OF THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY IMPROVEMENTS HE REQUIRES AT THE STAGING AREA(S) INCLUDING AN ENTRANCE, AGGREGATE SURFACING, TEMPORARY FENCING, ETC. CONTRACTOR SHALL PERFORM ADDITIONAL
IMPROVEMENTS AS HE DEEMS NECESSARY AND AS REQUIRED BY THE WORK.
14. ALL CONSTRUCTION WORK WILL BE CONFINED TO THE PERMANENT AND TEMPORARY EASEMENTS AS DEFINED ON THE DRAWINGS.
15. THE LIMITS OF THE CONSTRUCTION MATERIAL STORAGE AREAS, EQUIPMENT STORAGE AREAS, PARKING, AND OTHER AREAS DEFINED AS
REQUIRED FOR THE CONTRACTOR'S EXCLUSIVE USE DURING CONSTRUCTION SHALL BE MARKED BY THE CONTRACTOR AND COORDINATED WITH THE PROPERTY OWNER. THE CONTRACTOR SHALL ERECT AND MAINTAIN SUITABLE FENCING, MARKING AND/OR WARNING DEVICES, AND PREVENT UNAUTHORIZED PERSONNEL FROM ENTERING THE CONSTRUCTION SITE/AREAS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN ANY ADDITIONAL TEMPORARY CONSTRUCTION EASEMENTS FOR EITHER ACCESS OR LAY DOWN/STAGING AREAS IF THERE IS INSUFFICIENT SPACE WITHIN THE PERMANENT AND TEMPORARY EASEMENTS AS DEFINED ON THE DRAWINGS. CONTRACTOR SHALL OBTAIN THE PROPERTY OWNERS
PERMISSION IN WRITING AND PROVIDE SECURITY.
16. CONTRACTOR SHALL PROTECT ALL INFRASTRUCTURE. DAMAGE TO EXISTING OR NEW GROUNDS AND/OR FACILITIES CAUSED BY CONSTRUCTION TRAFFIC OR CONSTRUCTION OPERATIONS SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR TO MATCH OR EXCEED EXISTING/NEW UNDAMAGED CONDITIONS AT NO ADDITIONAL COST TO THE OWNER. CONTRACTOR SHALL CONTROL EXCESSIVE STORM WATER RUN-OFF FROM THE CONSTRUCTION SITE TO PREVENT SOIL EROSION USING BEST MANAGEMENT PRACTICES (BMPS) FROM ARIZONA DEPARTMENT OF ENVIRONMENTAL QUALITY (ADEQ). EROSION CONTROL MEASURES MUST BE INSTALLED PRIOR TO DISTURBING EXISTING GRADE WITHIN ANY WORK AREA. SUCH MEASURES SHALL REMAIN IN PLACE UNTIL WORK IS COMPLETE AND/OR GRASS IS ESTABLISHED, AS DIRECTED BY THE
CONTRACTING OFFICER REPRESENTATIVE.
17. CONTRACTOR SHALL REPAIR DAMAGED AND DISTURBED SOIL AREAS AT THE COMPLETION OF CONSTRUCTION ACTIVITIES THAT ARE NOT SLATED FOR PAVING OR COVERING. SUCH REPAIR SHALL CONSIST AT A MINIMUM, OF THE ADDITION OF 4" TOPSOIL, SEEDING, FERTILIZATION, AND WATERING REQUIREMENTS. RE-VEGETATED AREAS SHALL BE WATERED WITH A MINIMUM OF 1 INCH OF WATER PER WEEK FOR THE FIRST 30 DAYS, AND ANY AREAS THAT ARE DAMAGED OR FAIL TO REACH 80% ESTABLISHMENT SHALL BE RE-SEEDED.
18. CONTRACTOR SHALL PROVIDE AND INSTALL TEMPORARY TRAFFIC CONTROL DEVICES IN CONFORMANCE WITH THE ARIZONA SUPPLEMENT TO
THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES, 2009 EDITION.
19. DURING THE ENTIRE CONSTRUCTION PERIOD, THE CONTRACTOR SHALL MAINTAIN CONSTRUCTION WARNING SIGNS AT EACH SITE OF THE PROJECT TO WARN MOTORING AND PEDESTRIAN TRAFFIC THAT CONSTRUCTION IS IN PROGRESS AND OF POSSIBLE HAZARDOUS CONDITIONS GENERATED
BY THE CONSTRUCTION.
20.CONTRACTOR SHALL COORDINATE CONSTRUCTION WHICH BLOCKS TRAFFIC OF ANY STREET, ALLEY, OR DRIVEWAY WITH THE PROPERTY OWNER
AND CITY OF NOGALES.
21.CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR MAINTAINING A SAFE PROJECT SITE 24 HOURS A DAY.
22.CONTRACTOR SHALL PROVIDE PUMPS, PIPING, SHEET PILES, EQUIPMENT, ETC. AS REQUIRED TO DE-WATER AND KEEP WORK AREAS DRY.
23.DIMENSIONS AND/OR ELEVATIONS MARKED THUS "NTS" ARE SHOWN NOT TO SCALE.
24.CONTRACTOR SHALL COORDINATE WORK ACTIVITIES, INCLUDING ACCESS, WITH CITY OF NOGALES AND ENGINEER.
APPROVED FOR CONSTRUCTION
CITY OF NOGALES
TRACER WIRE AND BRICK ANCHOR
4-22-21
AutoCAD SHX Text D
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text D
B A Δ
PREPARED BY: 2424 E. Broadway Blvd., Suite 200 Tucson, AZ 85719
(520) 561-6467 ngeneng.com
WASTEWATER DESIGN OF LATERAL CONNECTIONS TO THE
INTERNATIONAL OUTFALL INTERCEPTOR (IOI) IN NOGALES, ARIZONA
GENERAL NOTES SHEET 2
IOI LATERAL LOCATION:
NOGALES, AZ
UTILITIES
1. PROTECTION OF EXISTING UTILITIES SHALL CONFORM TO SECTION 601.3 OF MAG (USSDPWC).
2. CONTRACTOR SHALL NOTIFY CITY OF NOGALES DIRECTOR OF DEPARTMENT OF PUBLIC WORKS AT LEAST 3 DAYS PRIOR TO GROUND BREAKING.
THE CONTRACTOR MAY BE REQUIRED BY THE CITY TO PLACE LEAFLETS AT THE DOORS OF AFFECTED CUSTOMERS OR OTHER OUTREACH
CONTACT METHOD.
3. UNLESS OTHERWISE SHOWN ON THE PLANS OR STATED IN THE SPECIFICATIONS, ALL UTILITIES, EITHER UNDERGROUND OR OVERHEAD, SHALL BE MAINTAINED IN CONTINUOUS SERVICE THROUGHOUT THE ENTIRE CONTRACT PERIOD. THE CONTRACTOR SHALL BE RESPONSIBLE AND LIABLE FOR ANY DAMAGES TO OR INTERRUPTION OF SERVICE CAUSED BY THE CONSTRUCTION. EFFORTS TO MAINTAIN SERVICE ARE
INCIDENTAL TO THE CONTRACT AND NO ADDITIONAL COMPENSATION IS PERMITTED.
4. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING SEWER SERVICE DURING CONSTRUCTION. THIS MAY INVOLVE TEMPORARY BYPASS OR STORAGE OR OTHER METHODS TO ALLOW SERVICE TO CITY OF NOGALES CUSTOMERS TO BE UNINTERRUPTED.
5. UTILITY INTERRUPTIONS SHALL BE SCHEDULED IN ADVANCE AND COORDINATED WITH THE AFFECTED UTILITY COMPANIES, AND OWNER, AS
APPROPRIATE FOR THE EFFICIENT EXECUTION OF THE WORK.
6. CONTRACTOR SHALL COORDINATE SHUTDOWN AND PROTECTION OF UTILITY LINES WITH OWNER. ALL WORK TO BE IN ACCORDANCE WITH THE
REQUIREMENTS OF THE APPLICABLE UTILITY COMPANY OR AGENCY INVOLVED.
7. CONTRACTOR SHALL CONTACT ARIZONA 811 (ARIZONA BLUE STAKE) 48 HOURS PRIOR TO BEGINNING WORK ON ANY PORTION OR SEGMENT OF
THE IOI LATERAL CONNECTION PROJECT TO LOCATE ANY UTILITIES WITHIN THE WORK ZONE.
8. THE CONTRACTOR SHALL KEEP ALL ARIZONA 811 REQUEST UP-TO-DATE, AND COMPLY WITH APPLICABLE ARIZONA REVISED STATUES PERTAINING TO ARIZONA 811. ERRORS IN ARIZONA 811 MUST BE REPORTED TO THE ENGINEER ASSIGNED BY THE CONTRACTING AGENCY.
9. THE CONTRACTOR SHALL VERIFY THE HEIGHT OF ALL AERIAL UTILITIES AND PERFORM SUBSURFACE UTILITY EXCAVATIONS AS NECESSARY FOR UNDERGROUND UTILITIES CROSSING THE PROJECT LIMITS.CONTRACTOR SHALL TAKE SPECIAL PRECAUTIONS IN THE VICINITY OF OVERHEAD ELECTRIC LINES, CONTRACTOR SHALL ABIDE BY NATIONAL ELECTRIC CODE AND/OR ANY REQUIREMENT OF THE OWNER OF THE
ELECTRIC LINE.
10. CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES AND SHALL BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES TO THE EXISTING PUBLIC OR PRIVATE UTILITY LINES, INCLUDING, BUT NOT LIMITED TO WATER LINES, SANITARY LINES,PROCESS LINES, STORM SEWERS, GAS, COMMUNICATIONS, AND ELECTRIC DURING CONSTRUCTION, WHETHER SHOWN ON THE PLANS OR NOT. ALL DAMAGES SHALL BE REPAIRED AT
NO COST TO THE CITY OF NOGALES OR ENGINEER.
TRENCHING EXCAVATION, BACKFILL AND COMPACTION
1. CONTRACTOR SHALL PROVIDE A TRENCH AND/OR EXCAVATION SAFETY PLAN TO MEET, AS A MINIMUM, THE REQUIREMENTS OF APPLICABLE
OSHA EXCAVATION, TRENCH, AND OTHER APPLICABLE SAFETY AND HEALTH REGULATIONS.
2. ALL TRENCHING EXCAVATION, BACKFILL AND COMPACTION SHALL CONFORM TO SECTION 601 OF MAG UNIFORM STANDARD SPECIFICATIONS
AND DETAILS FOR PUBLIC WORKS CONSTRUCTION (USSDPWC). SEE MAG STANDARD DETAILS ON SHEET 8.
3. CONTRACTORS SHALL HAVE SECTION 601 "TRENCHING EXCAVATION, BACKFILL, AND COMPACTION" AVAILABLE AT PROJECT SITE.
4. PER THE MAG-USSDPWC, THE CONTRACTOR SHALL, BUT IS NOT LIMITED TO:
4.1. PROVIDE, AT NO ADDITIONAL COST TO THE ENGINEER, ADDITIONAL LOAD BEARING CAPACITY IF THE MAXIMUM TRENCHING IS EXCEEDED, PER SECTION 601.2.2
4.2. REFILL UNAUTHORIZED EXCAVATION BELOW THE SPECIFIED TRENCH GRADE LINE AT THE CONTRACTOR’S EXPENSE WITH ABC MATERIAL COMPACTED TO A UNIFORM DENSITY OF NOT LESS THAN 95 PERCENT OF THE MAXIMUM DENSITY AS DETERMINED BY AASHTO T-99 AND T191 OR ASTM D6938. WHEN AASHTO T-99, METHOD A OR B, AND T-191 ARE USED FOR DENSITY DETERMINATION, ARIZ 227C WILL BE USED FOR
ROCK CORRECTION, PER SECTION 601.2.5
4.3. THE PLACEMENT OF THE ADDITIONAL MATERIAL DUE TO UNNECESSARY EXCAVATION BELOW THE ELEVATION INDICATED FOR THE FOUNDATION OF ANY STRUCTURE SHALL BE REPLACED AT NO COSTS TO THE AGENCY, PER SECTION 601.2.6.
4.4. SHALL SUBMIT A LETTER TO THE CONTRACTING AGENCY STATING THE LOCATION OF EACH DISPOSAL SITE FOR ALL EXCESS OR UNSUITABLE MATERIAL AND CERTIFY THAT HE HAS OBTAINED THE PROPERTY OWNER’S PERMISSION FOR THE DISPOSAL OF ALL SUCH MATERIAL, PRIOR
TO COMMENCEMENT OF THE WORK.
4.5. ALL EXCESS EXCAVATED MATERIAL AND SOIL SHALL BECOME PROPERTY OF CONTRACTOR AND TO BE REMOVED FROM SITE, AT NO ADDITIONAL COST TO THE CITY OF NOGALES OR ENGINEER. REMOVAL AND DISPOSITION SUBJECT TO THE APPROPRIATE DISPOSAL AND
PERMITTING REQUIREMENTS.
WORK RECOMMENDED TO BE PERFORMED UNDER THE CURED IN
PLACE PIPE (CIPP) PROJECT CONTRACT
1. IN PREPARATION FOR INSERTING THE CIPP LINER:
1.1. AFTER BYPASS IS SETUP, BRUSH OR SCRAPE DEBRIS AND LOOSE MATERIAL, INCLUDING PART OF LATERAL PIPE PROTRUDING INTO THE IOI.
1.2. REMOVE DEBRIS
1.3. PATCH AND FILL CRACKS AND HOLES IN THE IOI WITH WATERTITE COMPOUNDS COMPATIBLE WITH THE CIPP.
2. THE FOLLOWING TASKS ARE BEST FIT TO BE PERFORMED UNDER THE CIPP CONTRACT.
2.1. THE MARCH 2005 EVALUATION OF THE IOI REPORT BY BROWN AND CALDWELL IDENTIFIED TWO LATERALS CONNECTING TO THE IOI AT 12.2
FEET AND 162.9 FEET, RESPECTIVELY, FROM IOI MH #39 (SEE TABLE 2-2 BELOW). FIELD INVESTIGATIONS CONDUCTED BY CITY STAFF COULD NOT LOCATE THESE LATERALS, WHICH ARE PRESUMED TO BE ABANDONED. ANY PROTRUSION OF SUCH LATERALS INTO THE IOI SHALL BE
HANDLED BY THE CIPP CONTRACT. SEE HIGHLIGHTED TEXT IN TABLE 2-2.
2.2. A NON-STANDARD (MAKE-SHIFT) MANHOLE WAS DISCOVERED ON TOP OF THE IOI, 203 FEET UPSTREAM OF IOI MH #52 (SEE SHEET 6). CIPP
CONTRACT SHALL DECIDE ON WHAT IS TO BE DONE WITH SUCH MANHOLES.
DESIGNED BY:
DRAWN BY:
REVIEWED BY:
JOB. NO.
PROJ. NO.
SHEET
OF
DRAWING NO.
Tariq Tariq
Tariq Tariq
William O'Brien
T:\T17-001-2020 Nogales IOI 8 Laterals\AutoCAD\IOI-Laterals 100%.dwg
100% DESIGN
4-22-21
LATERALS NOT FOUND BY FIELD INVESTIGATIONS
CB
S
SS S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOI
PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE
PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE
S
IOI MH #3
RIM ELEV. 3850.76'
INV. ELEV. 3846.98'
N = 123002.84 E = 1004773.10
EXISTING INACTIVE LATERAL
CONNECTION TO IOI
6.2 FT UPSTREAM OF IOI MH #3
SEE NOTE 3
HISTORIC TRAIN
STATION BATHROOMS
STAIRWAY ENTRY TO
CONCRETE OVERLAID PARK N. MORLEY AVE.
W
. PA
R K
ST.
47' R O
A D
W A
Y
SHOPPING PLAZA
UNDERGROUND
CONCRETE BOX
CULVERT ON TOP OF IOI
20' WIDE BY 10' DEEP
20'
CL SLIDING TRACK
CL UNION PACIFIC NOGALES BRANCH (200' R.O.W.)
100'
EXISTING CURB
IOI MH #2
60' UPSTREAM
D C B A Δ
PREPARED BY: 2424 E. Broadway Blvd., Suite 200 Tucson, AZ 85719
(520) 561-6467 ngeneng.com
WASTEWATER DESIGN OF LATERAL CONNECTIONS TO THE
INTERNATIONAL OUTFALL INTERCEPTOR (IOI) IN NOGALES, ARIZONA
PLAN AND PROFILE: LATERAL SITE #1 IOI MH #2
IOI LATERAL LOCATION:
120 N. MORLEY AVE.,
NOGALES, AZ 85621
NOTES:
1. THE EXISTING SEWER LATERAL ALIGNMENTS SHOWN ARE BASED ON LIMITED FIELD
MEASUREMENTS AND OBSERVATIONS. THE ACTUAL LOCATIONS SHALL BE VERIFIED
THROUGH POTHOLING.
2. ACCESS TO THE ABANDONED LATERAL FROM WITHIN HISTORICAL BATHROOM REQUIRES
FIELD INVESTIGATION PRIOR TO DIGGING.
3. CONTRACTOR TO LOCATE BUILDING SEWER DRAIN WITHIN BATHROOMS; CUT, PLUG, AND
ABANDON LATERAL PER ABANDONMENT DETAIL ON THIS SHEET. CONTRACTOR SHALL
ENSURE NO DISTURBANCE TO THE TRAIN STATION BATHROOM HISTORICAL QUALITIES AND
RESTORE SITE TO EXISTING CONDITIONS.
4. ABANDONMENT OF LATERAL PIPE ON THE INSIDE OF IOI IS NOT PART OF THIS CONTRACT. SEE
SHEET 2, "WORK RECOMMENDED TO BE PERFORMED UNDER THE CURED IN PLACE PIPE (CIPP)
CONTRACT" NOTE 1.
KEY NOTES:
CUT, PLUG AND GROUT EXISTING SEWER LATERAL
CONNECTION TO IOI PER DETAIL ON THIS SHEET
MATERIALS LIST
ITEM UNIT QUANTITY
ABANDONMENT
WATERTIGHT CEMENT
NON-SHRINK GROUT (LOW
STRENGTH)
LF OF PIPE 32
EXPANDABLE PLUG EA 2
#20 COPPER TRACER WIRE
WITH YELLOW INSULATION LF 8 TO 12
ABANDONMENT
MONUMENT EA 1
EXISTING TRAIN STATION
BATHROOM BUILDING
SECTION OF
PIPE REMOVED
8" MIN.
EXPANDABLE PLUG
WATERTIGHT CEMENT
NON-SHRINK GROUT
EXISTING 4" Ø LATERAL
TO BE GROUTED UP TO
FLOOR LEVEL
37' TOTAL GROUT FILL
IOI
24" CP
60°
GROUT FILL LENGTH PER PLAN
GROUT FILL
ABANDONMENT DETAIL AT SITE #1
N.T.SSECTION VIEW
EXISTING GROUND
TRENCH
EXPANDABLE PLUG
PE
R
F
IE
LD
M
EA
SU
R
EM
EN
T
Feet 0 20 40
DESIGNED BY:
DRAWN BY:
REVIEWED BY:
JOB. NO.
PROJ. NO.
SHEET
OF
DRAWING NO.
Tariq Tariq
Tariq Tariq
William O'Brien
T:\T17-001-2020 Nogales IOI 8 Laterals\AutoCAD\IOI-Laterals 100%.dwg
100% DESIGN
2"
EXISTING TAP CONNECTION
SEE NOTE 4
4-22-21
PROVIDE COPPER TRACER WIRE AND BRICK
ANCHOR PER MAG DETAIL 427 AND ABANDONMENT
MONUMENT PER RWRD DETAIL 503 ON SHEET 11
TRACER WIRE
S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
IOI
PLE PLE PLE PLE PLE PLE PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
S
S
IOI MH #36
RIM ELEV. 3775.65'
INV. ELEV. 3758.81'
N = 131558.12 E = 1008133.82
IOI MH #37
RIM ELEV. 3775.71'
INV. ELEV. 3758.81'
N = 131838.51 E = 1008203.91
EXISTING 4" Ø LATERAL
(ABANDONED)
N. HOHOKAM DR.
N . D
ETEN
TIO
N R
D
CITY OF NOGALES
PUBLIC WORKS
PARKING LOT
CITY OF NOGALES
PUBLIC WORKS PARKING
LOT DRIVEWAY
CITY OF NOGALES
PUBLIC WORKS PARKING
LOT DRIVEWAY
IOI TRUNKLINE
30" Ø RCP PIPE
25'
25' TAP-IN CONNECTION
N=131732.88 E=1008177.51
EXISTING INACTIVE LATERAL
CONNECTION TO IOI
180 FT DOWNSTREAM OF IOI MH #36
SEE NOTES 2 AND 3
D C B A Δ
PREPARED BY: 2424 E. Broadway Blvd., Suite 200 Tucson, AZ 85719
(520) 561-6467 ngeneng.com
WASTEWATER DESIGN OF LATERAL CONNECTIONS TO THE
INTERNATIONAL OUTFALL INTERCEPTOR (IOI) IN NOGALES, ARIZONA
PROJECT LOCATION:
PLAN AND PROFILE: LATERAL SITE #4 IOI MH #36
1450 N. HOHOKAM DR.,
NOGALES, AZ 85621
NOTES:
1. CONTRACTOR TO LOCATE EXISTING SEWER LATERAL BY POTHOLING.
2. WORK AREA SHALL BE CONTAINED WITHIN THE SOUTHERN DRIVEWAY TO MINIMIZE
IMPACT ON TRAFFIC ON HOHOKAM DR.
3. CONTRACTOR TO REFILL, COMPACT, AND RE-PAVE DISTURBED AREA.
4. ABANDONMENT OF LATERAL PIPE ON THE INSIDE OF IOI IS NOT PART OF THIS CONTRACT.
SEE SHEET 2, "WORK RECOMMENDED TO BE PERFORMED UNDER THE CURED IN PLACE
PIPE (CIPP) CONTRACT" NOTE 1.
KEY NOTES:
CUT, PLUG, AND GROUT SEWER LATERAL
CONNECTION TO IOI PER DETAIL ON THIS SHEET
MATERIALS LIST
ITEM UNIT QUANTITY
ABANDONMENT
WATERTIGHT CEMENT
NON-SHRINK GROUT (LOW
STRENGTH)
LF OF PIPE 2
EXPANDABLE PLUG EA 2
#20 COPPER TRACER WIRE
WITH YELLOW INSULATION LF 8 TO 12
ABANDONMENT
MONUMENT EA 1 Feet
0 20 40
ABANDONMENT DETAIL AT SITE #4
N.T.SSECTION VIEW
1' G
R O
U T
FI
LL
SECTION OF
PIPE REMOVED
8" MIN.
1' GROUT FILL
EXPANDABLE PLUG
EXPANDABLE PLUG
WATERTIGHT CEMENT
NON-SHRINK GROUT
IOI
30" RCP
90°
EXISTING PAVED GROUND
REMAINING PIPE TO BE
ABANDONED IN PLACE
TRACER WIRE
EXISTING TAP CONNECTION
SEE NOTE 4
DESIGNED BY:
DRAWN BY:
REVIEWED BY:
JOB. NO.
PROJ. NO.
SHEET
OF
DRAWING NO.
Tariq Tariq
Tariq Tariq
William O'Brien
T:\T17-001-2020 Nogales IOI 8 Laterals\AutoCAD\IOI-Laterals 100%.dwg
100% DESIGN
2"
4-22-21
PROVIDE COPPER TRACER WIRE AND BRICK
ANCHOR PER MAG DETAIL 427 AND ABANDONMENT
X X
X X
X X
X
XXXXXXXXXXX
X
X
X X
X X
X X
X X
X X
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
IO
I
IO
I
IO
I
IO
I
IO
I
IO
I
IO
I
IO
I
IO
I
IO
I
IO
I
IO
I
IO
I
IO
I
IO
I
IO
I
IO
I
IO
I
IO
I PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
S
EXISTING 8" Ø ACTIVE
LATERAL
16" WATER LINE
PROPOSED LATERAL
ALIGNMENT FOR
CONNECTION TO IOI
N . H
O H
O K
A M
D R
FLEISCHER PARK
BASEBALL FIELD
FLEISCHER PARK
PARKING LOT
FIBER OPTICS
UTILITY LINE
TRENCH/EXCAVATION
BOUNDARY
FLEISCHER PARK
BATHROOM BUILDING
FL
O
W
C
PRESUMED LATERAL
CONNECTION TO IOI
MH#39 + 12.2 FT
SEE SHEET 2 NOTE 2.1
PRESUMED LATERAL
CONNECTION TO IOI
MH#39 + 162.9 FT
SEE SHEET 2 NOTE 2.1
EXISTING LATERAL CONNECTION TO IOI
155.5 FT DOWNSTREAM OF IOI MH #39
PLUG AND ABANDON
SEE NOTE 1
EXISTING CHAIN
LINK FENCE
IOI MH#39
RIM ELEV. 3762.98'
INV. ELEV. 3751.02'
N = 132884.08 E = 1008019.67
EXISTING CURB
EXISTING CURB
C
L=327.68', R=3360.75'
Δ=5.59
S45 ° 0
2' 4 1"W
8.6
1'
TWO-WAY CLEANOUT
PER MAG DETAIL 440-2
SEE SHEET 9
EXISTING MARKED STAKE
FOR LATERAL LOCATION
EXISTING STAIR
SEATING BENCHES
EXISTING SEATING BENCHES
EXISTING SEATING BENCHES
20'
20'
TRENCH/EXCAVATION
BOUNDARY
C
PROPOSED 8" Ø
SDR-35 PVC PIPE
PROPOSED 8" Ø TAP
INV. EL. 3754.57'
SEE NOTE 5
TOP OF IOI 30" Ø RCP PIPE
CROWN EL. 3753.48'±
L = 416.3' @ 0.33 % SLOPE
EXISTING GROUND
IOI MH #39
RIM ELEV. 3762.98'
STA. ELEV. 3751.02'
N=132884.08 E=1008019.67
TIE-IN TO BUILDING DRAIN
INV EL. 3755.94'
SEE NOTE 6
3'
16" WATER
STA. 3+91.0
DEPTH 8'
SEE NOTES 3 AND 4
CLEANOUT PER MAG 441
STA. 0+88.6
SEE SHEET 8
FIBER OPTICS UTILITY
STA. 3+98.3
DEPTH 3'
SEE NOTE 3
PROVIDE 8" TEE FITTING
AT TAP CONNECTION
SEE NOTE 10
TWO-WAY CLEANOUT PER MAG 440-2
STA. 0+00
SEE SHEET 9
2.9'
0.79'
D C B A Δ
PREPARED BY: 2424 E. Broadway Blvd., Suite 200 Tucson, AZ 85719
(520) 561-6467 ngeneng.com
WASTEWATER DESIGN OF LATERAL CONNECTIONS TO THE
INTERNATIONAL OUTFALL INTERCEPTOR (IOI) IN NOGALES, ARIZONA
PLAN AND PROFILE: LATERAL SITE #5 IOI MH #39
PROJECT LOCATION:
1500 N. HOHOKAM DR.,
NOGALES, AZ 85621
NOTES:
1. CONTRACTOR TO LOCATE EXISTING SEWER LATERAL BY POTHOLING.
2. PROPOSED SEWER LATERAL CONNECTION TO IOI MANHOLES SHALL BE THROUGH AN 8" PVC
SDR-35 PIPE.
3. DEPTH OF UTILITY LINE IS BASED ON LIMITED FIELD DATA AND NOGALES PUBLIC WORKS
REMAKRS, FIELD VERIFICATION IS REQUIRED.
4. 2.9' SEPARATION BETWEEN SEWER AND WATER. EXTRA PROTECTION IS NEEDED FOR WATER
LINE, PER MAG SECTION 610.
5. CONTRACTOR SHALL LOCATE AND AVOID ANY EXISTING TAP CONNECTIONS IN MANHOLE.
6. CONTRACTOR SHALL CONFIRM DEPTH/INVERT OF SEWER PIPE AT BUILDING TIE-IN
LOCATION. ABANDONMENT OF EXISTING LATERAL AT BUILDING TIE-IN LOCATION PER
DETAIL S2 ON SHEET 11.
7. ABANDONMENT OF LATERAL PIPE ON THE INSIDE OF IOI IS NOT PART OF THIS CONTRACT.
SEE SHEET 2, "WORK RECOMMENDED TO BE PERFORMED UNDER THE CURED IN PLACE PIPE
(CIPP) CONTRACT" NOTE 1.
8. ANY DISTURBANCES MADE TO THE SITE DURING CONSTRUCTION SHALL BE RESTORED TO
EXISTING CONDITIONS BY CONTRACTOR.
9. PIPE DEFLECTION SHALL NOT EXCEED MANUFACTURER'S RECOMMENDATION.
10. TEE FITTING SHALL BE CAPPED ON TOP BRANCH.
KEY NOTES:
CUT , PLUG AND GROUT EXISTING
SEWER LATERAL CONNECTION TO
IOI PER DETAIL ON THIS SHEET
2 CONSTRUCT 45° ELBOW
3 CONSTRUCT 8" Ø PVC SDR-35 SEWER
PIPE AS SHOWN
4 CONSTRUCT 8" SEWER CLEANOUT
PER MAG DETAIL 441 ON SHEET 8
Feet 0 20 40
Feet 0 20 40
Fe et
MATERIALS LIST
ITEM UNIT QUANTITY
PROPOSED LATERAL
8" PVC SDR-35 PIPE LF 416
SEWER CLEANOUT EA 3
45° ELBOW EA 1
6" TO 8" PVC ADAPTER FITTING EA 1
8" STANDARD TEE FITTING EA 1
ABANDONMENT
WATERTIGHT CEMENT NON-SHRINK GROUT (LOW STRENGTH) LF OF PIPE 19
EXPANDABLE PLUG EA 4
#20 COPPER TRACER WIRE WITH YELLOW INSULATION LF 16 TO 24
ABANDONMENT MONUMENT EA 2
' G
R O
U T
FI
LL
SECTION OF
PIPE REMOVED
1' GROUT FILL
EXPANDABLE PLUG
EXPANDABLE PLUG
WATERTIGHT CEMENT
NON-SHRINK GROUT
IOI
30" RCP
ABANDONMENT DETAIL AT SITE #5
N.T.SSECTION VIEW
90°
FLEISCHER PARK
COMPACTED SOIL
REMAINING PIPE TO BE
ABANDONED IN PLACE
SEE DETAIL S2 ON
SHEET 11 FOR
ABANDONMENT AT
UPSTREAM END
ED
G
E O
F
PA
V
EM
EN
T
8" MIN.
HOHOKAM DR.
PAVED ROADWAY
CUT AND GROUT FILL EXISTING
SEWER LATERAL CONNECTION TO
BUILDING PER DETAIL S2 ON SHEET 11
AND CONNECT PROPOSED LATERAL
PIPE TO BUILDING DRAIN USING 4" TO
8" PVC ADAPTER
EXISTING TAP
CONNECTION
SEE NOTE 7
DESIGNED BY:
DRAWN BY:
REVIEWED BY:
JOB. NO.
PROJ. NO.
SHEET
OF
DRAWING NO.
Tariq Tariq
Tariq Tariq
William O'Brien
T:\T17-001-2020 Nogales IOI 8 Laterals\AutoCAD\IOI-Laterals 100%.dwg
100% DESIGN
2"
4-22-21
COPPER TRACER WIRE AND BRICK
ANCHOR PER MAG DETAIL 427 AND
ABANDONMENT MONUMENT PER RWRD
DETAIL 503 ON SHEET 11
S S
S S
S S
S S
S S
S S
S S
S S
IOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOI
PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE
PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE
W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W
S
PROPOSED LATERAL ALIGNMENT
FOR CONNECTION TO IOI MH#52
NEW MANHOLE AT
CUTOFF POINT
EXISTING 4" Ø ACTIVE
LATERAL
IOI MH #52
RIM ELEV. 3703.11'
INV. ELEV. 3694.56'
N = 139527.66 E = 1004460.28
PLUG AND ABANDON EXISTING
LATERAL CONNECTION TO IOI
407.7 FT DOWNSTREAM OF IOI MH #51
SEE NOTE 1
EXISTING 16"
WATER LINE
W
. PR
O D
U C
E R O
W
MANUFACTURING
OUTSOURCING
SVCS
WAREHOUSE
BUILDING
S
EXISTING NON-STANDARD MANHOLE
N = 139393.48 E = 1004612.39
S
2 TRENCH/EXCAVATION
BOUNDARY
TIE-IN LOCATION
N=139408.02 E=1004626.42
N54° 14' 30"W 204.73' 3
20'
TOP OF 30" Ø RCP PIPE
CROWN EL. 3697.06'±
IOI MH #52
STA. 2+15.0
RIM ELEV. 3703.11'
INV. ELEV. 3694.56'
N=139527.66 E=1004460.28
4.2'
PROPOSED LATERAL
INV. EL. 3699.13'
PROPOSED 8" Ø
SDR-35 PVC PIPE
L = 204.73' @ 0.33 % SLOPE
EXISTING GROUND
PROPOSED 8" Ø TAP
INV. EL. 3698.45'
PROPOSED 48" Ø CONCRETE
MANHOLE PER MAG 420
SEE SHEET 10
PROVIDE 8" TEE FITTING
AT TAP CONNECTION
SEE NOTE 5
TOP OF 8" Ø CITY MAIN
CROWN EL. 3697.73'±
INV. EL. 3697.06'±
D C B A Δ
PREPARED BY: 2424 E. Broadway Blvd., Suite 200 Tucson, AZ 85719
(520) 561-6467 ngeneng.com
WASTEWATER DESIGN OF LATERAL CONNECTIONS TO THE
INTERNATIONAL OUTFALL INTERCEPTOR (IOI) IN NOGALES, ARIZONA
PLAN AND PROFILE: LATERAL SITE #7 IOI MH #52
PROJECT LOCATION:
2636 N. DONNA AVE.,
NOGALES, AZ 85621
CUT, PLUG, AND GROUT EXISTING SEWER LATERAL
CONNECTION TO IOI PER DETAIL ON THIS SHEET
2 CONSTRUCT 48" Ø MANHOLE PER MAG 420 DETAIL
ON SHEET 10
3 CONSTRUCT 8" Ø PVC SDR-35 SEWER PIPE AS
SHOWN
NOTES:
1. CUT, PLUG, AND GROUT EXISTING LATERAL CONNECTION TO THE IOI PER DETAIL ON THIS SHEET. EXISTING
LATERAL JOINS THE IOI THROUGH A MAKE-SHIFT MANHOLE. SEE "WORK RECOMMENDED TO BE PERFORMED
UNDER THE CURED IN PLACE PIPE (CIPP) CONTRACT" NOTE 2.2.
2. DEPTH/ELEVATION OF LATERAL AT TIE-IN LOCATION IS ESTIMATED USING CROWN EL. OF IOI AT CONNECTION POINT, 6" OF LATERAL DROP CONNECTION, AND ASSUMING A MINIMUM LATERAL SLOPE OF 0.84%. FIELD
VERIFICATION OF THE DEPTH IS REQUIRED DURING CONSTRUCTION.
3. PROVIDE NEW 48" Ø MANHOLE AT CUTOFF POINT. MANHOLE PER MAG STANDARD DETAIL 420. FRAME AND
COVER PER MAG STANDARD DETAIL 423-1. SEE SHEET 10.
4. ABANDONMENT OF LATERAL PIPE ON THE INSIDE OF IOI IS NOT PART OF THIS CONTRACT. SHEET 2, "WORK RECOMMENDED TO BE PERFORMED UNDER THE CURED IN PLACE PIPE (CIPP) CONTRACT" NOTE 1.
5. TEE FITTING SHALL BE CAPPED ON TOP BRANCH.
KEY NOTES:
Feet 0 20 40
Fe et
Feet 0 20 40
3'
5'
ABANDONMENT DETAIL AT SITE #7
SECTION VIEW
MATERIALS LIST
ITEM UNIT QUANTITY
PROPOSED LATERAL
8" PVC SDR-35 PIPE LF 205
48" Ø CONCRETE MANHOLE EA 1
24" Ø CAST IRON MANHOLE
COVER EA 1
8" STANDARD TEE FITTING EA 1
ABANDONMENT
EXPANDABLE PLUG EA 2
WATERTIGHT CEMENT
NON-SHRINK GROUT (LOW
STRENGTH)
LF OF PIPE 20
#20 COPPER TRACER WIRE
WITH YELLOW INSULATION LF 5
ABANDONMENT
MONUMENT EA 1
SECTION OF PIPE REMOVED
8" MIN.
IOI
30" RCP PIPEEXISTING TAP CONNECTION
SEE NOTE 4
EXISTING CONCRETE
NON-STANDARD MANHOLE
SEE SHEET 2 NOTE 2.2
GROUT PIPE UP TO
CUTOFF POINT PER PLAN
EXISTING GROUND
EXPANDABLE PLUG
EXPANDABLE PLUG
WATERTIGHT CEMENT
NON-SHRINK GROUT
TRACER WIRE
N.T.S
DESIGNED BY:
DRAWN BY:
REVIEWED BY:
JOB. NO.
PROJ. NO.
SHEET
OF
DRAWING NO.
Tariq Tariq
Tariq Tariq
William O'Brien
T:\T17-001-2020 Nogales IOI 8 Laterals\AutoCAD\IOI-Laterals 100%.dwg
100% DESIGN
2"
18' GROUT FILL 2' GROUT FILL
4.7"
4-22-21
PROVIDE COPPER TRACER WIRE AND BRICK
ANCHOR PER MAG DETAIL 427 AND ABANDONMENT
TOP OF 30" Ø RCP PIPE
CROWN EL. 3689.71'±
IOI MH #52B
STA. 2+00.4
RIM ELEV. 3697.35'
INV. ELEV. 3687.21'
N=140042.25 E=1003844.14
PROPOSED LATERAL
TIE-IN INV. EL. 3694.07'
CONNECT TO EXISTING
4" Ø LATERAL PIPE PER
DETAIL ON THIS SHEET
PROPOSED 8" Ø
SDR-35 PVC PIPE
EXISTING GROUND
PROPOSED 8" Ø TAP
INV. EL. 3692.12'
L = 200.35' @ 1.0 % SLOPE
EXISTING NE 4" Ø TAP
INV. 3690.15'
6'
TWO-WAY 8" CLEANOUT PER MAG 441
STA. 0+00.0
8" CLEANOUT PER MAG 441
STA. 0+20.0
3.9'
PROVIDE 8" TEE FITTING
AT TAP CONNECTION
SEE NOTE 8
X
X
X
X
X
X
X
X
X
X
X X
X X
X X
X X
X X
X
IOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOIIOI
PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE
PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE
W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W
S
IOI MH #52B
RIM ELEV. 3697.35'
INV. ELEV. 3687.21'
N = 140042.25 E = 1003844.14
EXISTING 16" WATER LINE
TO BE AVOIDED DURING
EXCAVATION
GVS
WAREHOUSE BUILDING CHAMBERLAIN
WAREHOUSE BUILDING
EXISTING WALL
PROPOSED LATERAL ALIGNMENT
FOR CONNECTION TO IOI MH#52B
DOUBLE 45° BEND
SEPARATED BY 20' PIPE
EXISTING 4" Ø ACTIVE LATERAL
ABANDONMENT PER DETAIL ON
THIS SHEET
SEE NOTE 2
C
EXISTING NE 4" Ø TAP
C
TRENCH/EXCAVATION
BOUNDARY
S87° 04' 51"W 20.00'
L=180.35', R=4315.49' Δ=2.39
C
15'
TIE-IN LOCATION
N=139918.74 E=1003996.22
D C B A Δ
PREPARED BY: 2424 E. Broadway Blvd., Suite 200 Tucson, AZ 85719
(520) 561-6467 ngeneng.com
WASTEWATER DESIGN OF LATERAL CONNECTIONS TO THE
INTERNATIONAL OUTFALL INTERCEPTOR (IOI) IN NOGALES, ARIZONA
PLAN AND PROFILE: LATERAL SITE #8 IOI MH #52B
PROJECT LOCATION:
1450 N. HOHOKAM DR.,
NOGALES, AZ 85621
NOTES:
1. CLEANOUT SIZE SHALL BE THE SAME AS THE PIPE BEING
CONNECTED TO.
2. CUTOFF POINT BETWEEN EXISTING AND PROPOSED LATERAL
SHALL BE WHERE THE EXISTING LATERAL CONNECTS TO THE
IOI PRIOR TO THE 2' DROP CONNECTION TO THE IOI.
3. ABANDONMENT OF LATERAL PIPE ON THE INSIDE OF IOI IS
NOT PART OF THIS CONTRACT. SEE SHEET 2, "WORK
RECOMMENDED TO BE PERFORMED UNDER THE CURED IN
PLACE PIPE (CIPP) CONTRACT" NOTE 1.
4. PROPOSED SEWER CONNECTION TO IOI MANHOLES SHALL BE
THROUGH AN 8" PVC SDR-35 PIPE.
5. CONTRACTOR SHALL CONFIRM DEPTH/INVERT OF EXISTING
SEWER PIPE AT TIE-IN LOCATION.
6. ANY DISTURBANCES MADE TO THE SITE DURING
CONSTRUCTION SHALL BE RESTORED TO EXISTING
CONDITIONS BY CONTRACTOR.
7. PIPE DEFLECTION SHALL NOT EXCEED MANUFACTURER'S
RECOMMENDATION.
8. TEE FITTING SHALL BE CAPPED ON TOP BRANCH.
CUT, PLUG AND GROUT EXISTING SEWER
LATERAL CONNECTION TO IOI PER
DETAIL ON THIS SHEET
2 CONSTRUCT 45° ELBOW BEND
3 CONSTRUCT 8" Ø PVC SDR-35 SEWER
PIPE AS SHOWN
4 CONSTRUCT 8" SEWER CLEANOUT
PER MAG DETAIL 441 ON SHEET 8
5 PROVIDE 4" TO 8" PVC ADAPTER
KEY NOTES:
MATERIALS LIST
ITEM UNIT QUANTITY
PROPOSED LATERAL
8" PVC SDR-35 PIPE LF 200
SEWER CLEANOUT EA 3
45° ELBOW EA 1
4" TO 8" PVC ADAPTER FITTING EA 1
8" STANDARD TEE FITTING EA 1
ABANDONMENT
WATERTIGHT CEMENT NON-SHRINK
GROUT (LOW STRENGTH) LF OF PIPE 2
EXPANDABLE PLUG EA 1
2' G
R O
U T
FI
LL
EXPANDABLE PLUG
IOI
30" RCP
ABANDONMENT DETAIL AT SITE #8
N.T.SSECTION VIEW
90°
EXISTING GROUND
EXISTING TAP CONNECTION
SEE NOTE 3
PIPE TO SOURCE
(TO REMAIN)
EXISTING 90° ELBOW TO BE
REMOVED AND REPLACED WITH
4" TO 8" PVC ADAPTER FITTING
PROPOSED 4" TO
8" PVC ADAPTERPROPOSED 8" Ø
PVC SDR-35 PIPE
PER PLAN VIEW
EXISTING 4" Ø
LATERAL PVC PIPE
(TO REMAIN)
Fe et
Feet 0 20 40
Feet 0 20 40
CONSTRUCT TWO-WAY 8" SEWER
CLEANOUT PER MAG DETAIL 440-2
ON SHEET 9
DESIGNED BY:
DRAWN BY:
REVIEWED BY:
JOB. NO.
PROJ. NO.
SHEET
OF
DRAWING NO.
Tariq Tariq
Tariq Tariq
William O'Brien
T:\T17-001-2020 Nogales IOI 8 Laterals\AutoCAD\IOI-Laterals 100%.dwg
100% DESIGN
2"
4-22-21
B A Δ
PREPARED BY: 2424 E. Broadway Blvd., Suite 200 Tucson, AZ 85719
(520) 561-6467 ngeneng.com
WASTEWATER DESIGN OF LATERAL CONNECTIONS TO THE
INTERNATIONAL OUTFALL INTERCEPTOR (IOI) IN NOGALES, ARIZONA
DETAILS SHEET
PROJECT LOCATION:
NOGALES, ARIZONA
THE WORD 'SEWER'
ON COVER
UNPAVED STREETS
AND ALLEYS
PAVED STREETS
AND ALLEYS
COMPACTED BACKFILL
OR UNDISTURBED EARTH
STANDARD
45° BEND
STANDARD
45° BEND
VIT. CLAY PIPE
PER SECT. 743
SIZE OF PIPE
AS SHOWN
ON PLANS
FLOW LINE ELEVATION
SHOWN ON PLANS TO
THIS POINT
STATION AND LENGTH SHOWN
ON PLANS TO THIS POINT
TO BE LAID ON UNDISTURBED
EARTH OR COMPACTED SELECT
MATERIAL (TYPE B) OR A.B.C.
ONE FULL
LENGTH OF
PIPE
6"
CLEANOUT INSTALLATION SEWER TAP AT CLEANOUT
6"x8" OR 4"x8"
VITRIFIED CLAY
INCREASER
8"x8" WYE
CLASS 'AA' CONC.
PER SECT. 725, 6"-8"
THICK, 40" DIA.
5" M
IN
1/
4" M
A X
8" V.C.P.
4" OR 6" V.C.P.
TAP TO PROPERTY
LINE
8" C.I. FRAME
AND COVER DET. 270
END OF SEWER TAP TO BE SEALED AND
MARKED IN ACCORDANCE WITH DET. 440
SEWER CLEANOUT441
DETAIL NO.
ENGLISH
STANDARD DETAIL REVISED
01-01-2001 441
DETAIL NO.
NOTES:
TRENCH BACKFILL AND
200-1 SURFACE REPLACEMENT
DETAIL NO.
ENGLISH
STANDARD DETAIL REVISED
01-01-2020 200-1
DETAIL NO.
TRENCH WIDTH
PER SECTION 601.2
BASE:
A.B.C. PER SECT.
702 & 601
12" MIN OR
MATCH EXISTING
BASE, WHICHEVER
IS GREATER
FINAL BACKFILL:
CLSM, A.B.C, GRANULAR
BACKFILL, OR NATIVE
BACKFILL (SEE NOTES)
SHELF
48" MIN12"
MIN
12"
MIN
TRENCH WIDTH
PER SECTION 601.2
BASE:
A.B.C. PER SECT.
702 & 601
48" MIN12"
MIN
12"
MIN
A.C. SURFACE &
BASE COURSES
(SEE NOTE 1)
24"
TRENCH WIDTH
PER SECTION 601.2
BASE:
A.B.C. PER SECT.
702 & 601
A.C. SURFACE &
BASE COURSES
(SEE NOTE 1)
MATCH EXISTING
THICKNESS
(FOR PAVEMENT > 4" THICK)
TRENCH WIDTH
PER SECTION 601.2
12"
MIN
12"
MIN
SURFACING: MATCH
TYPE & THICKNESS
OF EXISTING
(TRENCH NOT UNDER CONCRETE OR ASPHALT PAVEMENT)
48" MIN
BASE (IF EXISTING):
MATCH TYPE &
THICKNESS
OF EXISTING, BUT
NO LESS THAN 9"
TRENCH WIDTH
PER SECTION 601.2
(TRENCH IN FUTURE ROADWAY PRISM OR ALLEY)
24"
MATCH ADJACENT GROUND SURFACE
WHEN FINAL STREET ELEVATION IS UNKNOWN.
OTHERWISE, PLACE TO FINISHED SUBGRADE.
BASE:
A.B.C, GRANULAR
BACKFILL, OR *NATIVE
BACKFILL (SEE NOTES)
1. PAVEMENT MATCHING, BASE COURSES AND SURFACE REPLACEMENT SHALL BE IN ACCORDANCE WITH SECTION 336 UNLESS OTHERWISE SPECIFIED IN CONTRACT DOCUMENTS.
2. TRENCH EXCAVATION, BACKFILLING AND COMPACTION SHALL BE IN ACCORDANCE WITH SECTION 601. NATIVE BACKFILL SHALL ONLY BE USED WITH AGENCY APPROVAL.
3. CLSM SHALL BE 1/2-SACK OR 1-SACK PER SECTIONS 604 AND 728.
4. MATERIAL FOR FINAL BACKFILL AND BASE (IF APPLICABLE) SHALL BE AS NOTED HEREIN UNLESS OTHERWISE SPECIFIED IN CONTRACT DOCUMENTS.
5. FINAL BACKFILL SHALL BE CLSM FOR TRENCH DEPTHS GREATER THAN 4 FEET UNLESS A SAFE (OHSA COMPLIANT) WORKING SPACE AT LEAST 30" WIDE IS PROVIDED TO CONDUCT COMPACTION TESTING.
6. PROVIDE MINIMUM 12" WIDE SHELF AS SHOWN IN "T-TOP" TRENCH REPAIR AT ENDS OF TYPE "A" TRENCH REPAIR EXCEPT WHERE EDGE ABUTS EXISTING CONCRETE.
7. USE "T-TOP" PAVEMENT REPLACEMENT WHERE A TRENCH IS NOT PARALLEL TO A STREET OR GOES THROUGH AN INTERSECTION.
8. THE JOINT LOCATION OR JOINT CONFIGURATION MAY VARY FROM THAT SHOWN TO ELIMINATE REMNANTS, TO ELIMINATE FULL DEPTH SAWCUT JOINTS FROM BEING LOCATED WITHIN A WHEEL PATH AS REQUIRED BY SECTION 336, OR WHEN AN OFFSET JOINT IS CONSTRUCTED. SEE DETAIL 200-2 FOR REMNANT PAVEMENT REMOVAL REQUIREMENTS.
9. SAWCUT OR MILL EDGE AND APPLY TACK COAT. FOR PERMANENT PAVEMENT, APPLY 2-1/2" WIDE SECTION 337.2.1 COMPLIANT JOINT SEALANT AS REQUIRED BY AGENCY - SEE DETAIL ON 200-2.
10. EXPOSED COPPER OR POLYETHYLENE WATER PIPE UP TO 2" IN DIAMETER IN TRENCHES TO BE BACKFILLED WITH CLSM SHALL BE WRAPPED WITH MINIMUM 3/4" THICK PREFORMED PIPE-COVERING FOAM INSULATION BEFORE
PLACING CLSM.
SAWCUT OR MILL EDGE, TACK & SEAL
SEE NOTES 8 & 9
TRENCH CROSS-SECTION
TYP. SEE DETAIL 200-2.
TRENCH CROSS-SECTION
TYP. SEE DETAIL 200-2.
TRENCH CROSS-SECTION
TYP. SEE DETAIL 200-2.
TRENCH CROSS-SECTION
TYP. SEE DETAIL 200-2.
TRENCH CROSS-SECTION
TYP. SEE DETAIL 200-2.
"T TOP" TRENCH REPAIR TYPE "A" TRENCH REPAIR TYPE "B" TRENCH REPAIR
OFFSET JOINT
TYPE "D" TRENCH REPAIR TYPE "E" TRENCH REPAIR
6" MIN
AC SURFACE COURSE REPLACEMENT
MILL
2" MIN
2" MIN
THICKNESS
4" MIN
(12" MIN)
EDGE OF BASE FOR TYPE 'B'
AND 'T' TOP TRENCH REPAIR
EDGE OF BASE FOR
TYPE 'A' TRENCH REPAIR
EXIST AC
REPLACED AC BASE COURSE
FULL DEPTH PVMT CUT
FINAL BACKFILL:
CLSM, A.B.C, GRANULAR
BACKFILL, OR NATIVE
BACKFILL (SEE NOTES)
FINAL BACKFILL:
CLSM, A.B.C, GRANULAR
BACKFILL, OR NATIVE
BACKFILL (SEE NOTES)
FINAL BACKFILL:
CLSM, A.B.C, GRANULAR
BACKFILL, OR *NATIVE
BACKFILL (SEE NOTES)
FINAL BACKFILL:
CLSM, A.B.C, GRANULAR
BACKFILL, OR NATIVE
BACKFILL (SEE NOTES)
(USE FOR TRANSVERSE TRENCH REPAIRS, SEE DETAIL 200-2) (USE FOR LONGITUDINAL TRENCH REPAIRS, SEE DETAIL 200-2) (USE FOR TRANSVERSE TRENCH REPAIRS IF SPECIFIED BY AGENCY)
RESTORE SURFACE OUTSIDE OF TRENCH LINES DAMAGED
DURING CONSTRUCTION WITH LIKE MATERIAL TO ORIGINAL CONDITION
SAWCUT OR MILL EDGE, TACK & SEAL
SEE NOTES 8 & 9
SAWCUT OR MILL EDGE, TACK & SEAL
SEE NOTES 8 & 9
OFFSET JOINT
OPTION (TYP)
OFFSET JOINT
OPTION (TYP)
OFFSET JOINT
OPTION (TYP)
*NATIVE BACKFILL WITH
AGENCY APPROVAL TYP.
WHERE ROADWAY IS NOT
PLANNED FOR MORE THAN
TWO YEARS.
TRENCH BACKFILL AND
200-2 SURFACE REPLACEMENT
DETAIL NO.
ENGLISH
STANDARD DETAIL REVISED
01-01-2020 200-2
DETAIL NO.
(TRENCH IN PAVEMENT PARALLEL TO TRAFFIC)
C OF STREET
EXISTING S/W TYP.
TRENCH
EXISTING C/G TYP.
EXISTING
PAVEMENT
C OF STREET
TRENCH
EXISTING C/G TYP.
EXISTING
PAVEMENT
(TRENCH IN PAVEMENT NOT PARALLEL TO TRAFFIC)
TRENCH
EXISTING
S/W TYP.
REMOVE IF REMNANT
IS 48" WIDE OR LESS AND
RESTORE PER DETAIL 200-1
CURB, GUTTER, CONCRETE
PAVEMENT OR OTHER
CONCRETE STRUCTURE
TYPE "A",
TYPE "B" OR
"T-TOP"
TRENCH REPAIR
EXIST AC
BEDDING
IN
IT
IA
L
B A
C K
FI
LL
TOP OF PIPE, CONDUIT
OR CONCRETE-ENCASED
DUCT BANK
12"
1. SEE SECTION 601 FOR TRENCH EXCAVATION, BACKFILLING AND COMPACTION REQUIREMENTS.
2. SEE DETAIL 200-1 FOR DETAILED TRENCH REPAIR REQUIREMENTS FOR TRENCH TYPES NOTED HEREIN.
3. SEE DETAIL 211 FOR REQUIREMENTS REGARDING THE USE OF PLATING TRANSVERSE TRENCHES. USE OF STEEL PLATES SHALL NOT EXCEED 72 HOURS AFTER COMPLETION OF BACKFILL AND PRIOR TO FINAL PATCHING.
FOUNDATION
SPRINGLINE
FINAL BACKFILL
HAUNCHING
MINIMUM WIDTH AT
SPRINGLINE ON EACH
SIDE OF PIPE
TRENCH WIDTH
PI
PE
EM
B
ED
M
EN
T
ZO
N
E
REMNANT PAVEMENT REMOVALTRENCH CROSS-SECTION DETAIL
NOTES:
LONGITUDINAL TRENCH TRANSVERSE TRENCH
EDGE OF CONCRETE
2-1/2"
JOINT SEALANT DETAIL
JOINT/CUT
EXISTING
PAVEMENT
PAVEMENT
PATCH
SEALANT
NOT USED
DESIGNED BY:
DRAWN BY:
REVIEWED BY:
JOB. NO.
PROJ. NO.
SHEET
OF
DRAWING NO.
Tariq Tariq
Tariq Tariq
William O'Brien
T:\T17-001-2020 Nogales IOI 8 Laterals\AutoCAD\IOI-Laterals 100%.dwg
100% DESIGN
4-22-21
%%UNOTE:
B A Δ
PREPARED BY: 2424 E. Broadway Blvd., Suite 200 Tucson, AZ 85719
(520) 561-6467 ngeneng.com
WASTEWATER DESIGN OF LATERAL CONNECTIONS TO THE
INTERNATIONAL OUTFALL INTERCEPTOR (IOI) IN NOGALES, ARIZONA
DETAILS SHEET 2
PROJECT LOCATION:
NOGALES, ARIZONA
ZONE A
ZONE B
4' 4'2' V A
R
IE
S
VARIES
GRAVITY
SANITARY
SEWER MAIN
GRAVITY SANITARY SEWER
NOTES:
ZONE A: NO WATER LINES ALLOWED/MINIMUM SEPARATION.
ZONE B: EXTRA PROTECTION REQUIRED FOR WATER LINES.
* REFER TO SECTION 610, WATER LINE CONSTRUCTION.
WATER AND SANITARY SEWER
404-1
DETAIL NO.
SEPARATION/PROTECTION
2'
2'
2'
ENGLISH
STANDARD DETAIL REVISED
404-1
DETAIL NO.
01-01-2020
WATER LINE EXCLUSION AND EXTRA PROTECTION ZONES*
1'
10' MIN.
PERPENDICULAR PERPENDICULAR
ENCASEMENT FOR PIPE CROSSING*
LOWER WATER OR
SEWER MAIN
6" 6"
6"
6"
SECTION A-A
SE
PA
R A
TI
O
N D
IS
TA
N C
E
4" 2"2"
V A
R
IE
S
2"
4"
(4) NO.4 BARS
NO. 3 STIRRUPS
PERPENDICULARPERPENDICULAR
10' MIN.
24" 36"
HIGHER WATER OR
SEWER MAIN
2"
4"
A
A
V A
R
IE
S
WATER AND SANITARY SEWER
404-3
DETAIL NO.
SEPARATION/PROTECTION
4"
10' MIN. 10' MIN.
ENGLISH
STANDARD DETAIL
36" O.C.
REVISED
404-3
DETAIL NO.
1. CLASS 'C' CONCRETE AS PER SECTION 725.
NOTES:
01-01-2020
*REFER TO SECTION 610, WATER LINE CONSTRUCTION.
STIRRUPS
EDGE SPACING
STIRRUPS
SPACING
TYPE 'B' - SEWER BUILDING CONNECTION
TWO-WAY CLEANOUT AND METER BOX AT R/W440-2
DETAIL NO.
STANDARD DETAIL
ENGLISH
REVISED
440-2
DETAIL NO.
01-01-2007
SIZE OF TAP SHALL BE DESIGNATED ON
PLANS.
CONSTRUCT TAP AT MINIMUM SLOPE IF
COVER WILL BE LESS THAN 5' AT
PROPERTY LINE.
END OF TAP TO BE SEALED AND
MARKED AS NOTED.
1.
2.
3.
4.
5.
6.
IF DEPTH REQUIRES, MINIMUM SLOPE CAN
BE REDUCED TO 1/8" PER FOOT PROVIDED
STUB IS STAKED TO GRADE.
CONSTRUCTION DETAIL APPLIES WHERE
CONTRACTOR BUILDS HOUSE CONNECTION.
TAP EXTENDS TO PROPERTY LINE IN
ALLEYS OR STREETS OR TO EASEMENT LINE.
ALL FITTINGS SHALL BE INSTALLED IN
ACCORDANCE WITH ASTM D-2321. THE
CONTRACTOR MAY VARY FROM THE
DRAWING TO USE THE APPROPRIATE WYES,
TEE-WYES AND BENDS TO ENSURE NO
MISALIGNMENT OF THE PIPE AND FITTINGS.
BLOCK OR BRACE FITTING JOINTS TO
ENSURE ZERO DEGREES ANGULAR JOINT
DEFLECTION.
7.
M A
IN
FLOW
4" OR 6"
45° WYE BRANCH
4" OR 6"
45° BENDS
SEWER PIPE
MAX: 6" = 7/8" PER FT.
MAX: 4" = 1-1/2" PER FT.
MIN: 4" OR 6" = 1/4" PER FT.
SLOPE:
SLOPE
VARIABLE)
MAIN (SIZE
2" x 4" METAL STUD OR
20 GUAGE COPPER
WIRE WITH YELLOW
INSULATION AT P
4" OR 6"
ELECTRONIC MARKER
2- WAY CLEANOUT
W/ THREADED CAPS
6"
#2 METER BOX PER
DETAIL 320
INVERT OF SERVICE LINE TO BE
AT OR ABOVE CROWN OF MAIN
6"
ELECTRONIC MARKER SHALL BE A
3M MODEL 1424-XR/iD [4" DIAMETER SELF
LEVELING MARKER BALL GREEN IN COLOR]
OR APPROVED EQUAL OR AS REQUIRED
BY THE LOCAL AGENCY.
8.# 14 BARE COPPER LOCATOR WIRE
ACCESSIBLE AT R/W AND AT
PROPERTY OWNER CLEANOUT
BOX NO GREATER THAN 4' DEEP.
2' M
IN
R/W LINE
SE
E
N O
TE
STAMP OR WELD THE LETTER "S" ON LID
OF METER BOX.
9.LEVEL
ELECTRONIC MARKER
L
(WHEN SPECIFIED BY LOCAL AGENCY)
4' M
A X
NOT USED
NOT USED
TAP TO MANHOLE PER PLAN AND PROFILE
PRESSURIZED SANITARY SEWER
NOT USED
BB
B I
I
3- 1/
2" F
CA
J J
K K
L L
G H
J K K L L
J
E
M
C
3- 1/
2" J
A
A
WATER METER BOX
COVER FITTING BOX NO. 1, 2, 3,
OR 4 AS REQUIRED.
SEE APPLICABLE DETAIL
PLAN VIEW
SECTION B-B
SECTION A-A
METER BOX DIMENSIONS
BOX NUMBERDIMS 1 2 3 4
A B C D E F G H I J K L M
18-1/2" 11-3/4"
12" 14" 16"
9-1/4" 7"
9-1/4" 5-7/8" 1-1/2" 3/4" 1/4" 16"
25" 17-1/4"
12" 20"
22-1/8" 14-1/2" 12-1/2" 14-1/4" 8-5/8" 1-1/2" 1/2" 1/2"
21-7/8"
28-3/8" 17-5/8"
12" 24"
26-1/4" 15-1/8"
13" 15-1/4" 8-7/8" 2-1/4" 3/4" 1/2" 26"
33-1/8" 22-3/8"
12" 27-3/4" 30-5/8" 19-3/4"
17" 19-3/4" 11-1/8" 1-1/2" 5/8" 5/8"
30-1/2"
2"
METER
1-1/2"
METER
1"
METER
5/8" OR
3/4" METER
D
DETAIL NO.
ENGLISH
STANDARD DETAIL REVISED
DETAIL NO.
01-01-2017
O
O 1/2" 1/2" 1/2" 5/8"
NON TRAFFIC RATED
WATER METER BOXES
DESIGNED BY:
DRAWN BY:
REVIEWED BY:
JOB. NO.
PROJ. NO.
SHEET
OF
DRAWING NO.
Tariq Tariq
Tariq Tariq
William O'Brien
T:\T17-001-2020 Nogales IOI 8 Laterals\AutoCAD\IOI-Laterals 100%.dwg
100% DESIGN
4-22-21
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
PRESSURE
AutoCAD SHX Text
OR FORCE
AutoCAD SHX Text
SEWER MAIN
AutoCAD SHX Text
SANITARY
AutoCAD SHX Text
ZONE B
AutoCAD SHX Text
ZONE A
AutoCAD SHX Text 6'
AutoCAD SHX Text
VARIES
AutoCAD SHX Text 6'
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
ZONE B
AutoCAD SHX Text 4'
AutoCAD SHX Text 2'
2'
B A Δ
PREPARED BY: 2424 E. Broadway Blvd., Suite 200 Tucson, AZ 85719
(520) 561-6467 ngeneng.com
WASTEWATER DESIGN OF LATERAL CONNECTIONS TO THE
INTERNATIONAL OUTFALL INTERCEPTOR (IOI) IN NOGALES, ARIZONA
DETAILS SHEET 3
PROJECT LOCATION:
NOGALES, ARIZONA
TYPE 'A' TOP
420-1
(PRECAST ECCENTRIC CONICAL TOP MANHOLE)
CONCRETE SANITARY SEWER MANHOLE
DETAIL NO. STANDARD DETAIL
ENGLISH 01-01-2015
REVISED
420-1
DETAIL NO.
USE BUTYL RUBBER
MASTIC JOINT
SEALANT ON ALL
JOINTS; EXCEPT TOP
ADJUSTMENT RINGS
8" IF MANHOLE IS 13' OR LESS
12" IF MANHOLE IS OVER 13'
OVERALL ADJUSTMENT
RING HEIGHT SHALL BE
12" MIN TO 18" MAX (TYP)
NOTES:
1. PRECAST STEEL REINFORCED MANHOLE SECTIONS
SHALL BE MANUFACTURED IN ACCORDANCE WITH
ASTM C 478 EXCEPT AS MODIFIED HEREIN.
2. CAST-IN-PLACE MANHOLE BASE TO BE CONSTRUCTED
IN ONE PLACEMENT.
3. CAST-IN-PLACE MANHOLE BASE SHELF AND CHANNEL
TO RECEIVE SMOOTH TROWEL FINISH.
4. MANHOLE COATINGS PER AGENCY.
5. SEE MAG DETAIL 422 FOR FINAL ADJUSTMENT TO
GRADE.
6. ANY MANHOLE OVER 20' SHALL REQUIRE ENGINEER
(STRUCTURAL) CALCS.
7. THE MANHOLE ACCESS POINT SHALL BE ORIENTED IN
SUCH A WAY THAT THE OPENING IS DIRECTLY ABOVE
THE LOWEST INVERT, OR AS OTHERWISE DIRECTED BY
THE PLANS OR ENG.
8. FOR PRECAST BASE SEE DETAIL 420-2.
9. FLAT TOPS SHALL ONLY BE USED WITH APPROVAL
FROM THE ENGINEER.
PRECAST RISER
SECTIONS AS REQUIRED
24" OR 30" FRAME
& COVER PER DET.
423, 424, 425 (TYP)
(PRECAST FLAT TOP M.H.)
8" TYP.
3" MIN.
5" MAX.
KEYWAY PRESSED INTO
BASE TO MATCH
PRECAST RISER
DIAMETER
PER PLAN
FLAT REINFORCED
CONC. TOP
FINISH
GRADE
(TYP)
24" TO 26-3/4" ON 48"
MANHOLE 30" ON
60" MANHOLE (TYP)
CEMENT MORTAR
CLASS "A"
CONCRETE BASE PER
SECTION 725, 505
30" MIN.
36" MAX.
24" MAX ADJUSTING
RINGS PER DETAIL
422 (TYP)
CONCRETE SHELF SHALL
BE PER DETAIL 420-3
SECTION A-A
24"
MAX.
30"DIA MIN.
FLOW
420-3
DETAIL NO. STANDARD DETAIL
ENGLISH 01-01-2015
REVISED
420-3
DETAIL NO.
CONCRETE MANHOLE BASE
IF NO SIDE SEWERS, FORM
ONE CONTINUOUS CHANNEL
CHANNEL TRANSITION SHALL BE
CONSISTENT FROM INLET TO OUTLET OF
MANHOLE TO FACILITATE SMOOTH
TRANSITIONS AND ACCOMMODATE
CORRESPONDING MANDREL.
SECTION A-A
AA
TYPICAL CHANNEL
TOP OF SHELF TO
TOP OF PIPE
(MIN 2% SLOPE)
NOT
TO EXCEED 3"
90° MIN ANGLE
2"± RADIUS
90° MIN ANGLE
CHANNEL, FORMED WITH PRECAST
AND CAST IN PLACE BASE, (TYP).OUTLET PIPE PER
APPROVED PLANS
OUTLET PIPE
PER APPROVED
PLANS
SEE DETAIL 420-2 FOR NOTES
FLOW
FLOW
FLOW
FLOWFLOW
PROVIDE A ±12 INCH
TANGENT AT ALL
PIPE CONNECTIONS
(TYP)
2"± RADIUS
420-2
DETAIL NO. STANDARD DETAIL
ENGLISH
REVISED
420-2
DETAIL NO.
PRECAST CONCRETE MANHOLE BASE 01-01-2015
PROVIDE 1' LENGTH OF
FACTORY PRODUCED CLAY
PIPE
STANDARD LENGTH PIPE
PROVIDE 2' LENGTH OF
FACTORY PRODUCED EXTRA
STRENGTH VITRIFIED CLAY
PIPE
FLOW
OUTLET PIPE PER
APPROVED PLANS
UNDISTURBED
NATIVE SOIL5
FLOW
8" MIN.
TRENCH FACE (TYP)
24" CAST IRON
MANHOLE FRAME AND COVER423-1
DETAIL NO.
ENGLISH
STANDARD DETAIL REVISED
423-1
DETAIL NO.
01-01-2020
FRAME TOP VIEW COVER TOP VIEW
MIN. 8 GUSSETS
W/ MIN. TAPER
5/8" TO 3/4"
FRAME WT. (CL. 35) - 180 LBS
B B
NAME OF AGENCY
OR UTILITY
REQUIRED 1/8" RAISED
COVER BOTTOM VIEW
1 3/8"
TAPER TO
1 1/4"
XX
XX
HEAT DATE
M
AD
E
IN
U
SA
XXX
MANUFACTURER'S NAME
1 1/16"
26 1/8" 1 3/16"
22 3/4"
2 1/2"
COVER WT. (CL. 35) - 188 LBS
CLASS 35B
XX
X
MANUFACTURER'S NAME
ORIGIN
AASHTO M306
MODEL NUMBER
AASHTO M
CLASS 35B
XX
XX
HEAT DATE
USA
CLASS 35B
AASHTO M306
XXX
MODEL NUMBER
MANUFACTURER'S NAME RECYCLE SIGN
XXX
NC
AG
E
IY DENTIF ICATION
U T I L I T Y T YPE
OPTIONAL LOGO
OR AREA WITH
RAISED CIRCLE
RAISED RINGS 1/8"
FLUSH 1/8"
33 3/4"
TAPER
1/2" TO
3/4"
6"
26 3/8" 27 13/16"
1 3/16"
4 1/16"
24"
R3/4"
1/8"
BATTER 3/16"
3/16"
BATTER
NOTE:
LETTERING ON MANHOLE COVER TO CONTAIN NAME OF AGENCY AND UTILITY FOR WHICH MANHOLE IS NEEDED, (I.E. "PHOENIX SANITARY SEWER"), OR AS DIRECTED. THE TOTAL WIDTH OF INDIVIDUAL LETTERS TO BE SUCH THAT LETTERS AND WORDS ARE EQUALLY SPACED AND BALANCED TO FORM A COMPLETE CIRCLE WITH SPACERS BEFORE AND AFTER THE WORD IDENTIFYING THE AGENCY INVOLVED. LETTERS TO BE 2" IN HEIGHT AND RAISED FLUSH W/ TOP OF RINGS. TYPE OF LETTERS TO BE SUBMITTED FOR APPROVAL. WEIGHT OF CASTINGS SHALL BE NO MORE THAN 2% MORE OR LESS THAN THE APPROXIMATE WEIGHT SPECIFIED. CASTINGS SHALL CONFORM TO ASTM A-48, CLASS 35 AND AASHTO M306. THE BEARING SURFACES OF THE FRAMES AND COVERS SHALL BE MACHINED AND THE COVERS SHALL SEAT FIRMLY WITHOUT ROCKING. ALL DIMENSIONS SHALL HAVE A 1/16"
TOLERANCE.
1 1/2" DEEP
A A
C
C
SECTION BSECTION CSECTION A SECTION D
D
D
3/16"
BATTER
3/4"
R1/4"
R3/8"
1 3/8" 7"
MACHINED
MACHINED
NOTES:
PRECAST, MANUFACTURER SHALL BE AN NATIONAL PRECAST
CONCRETE ASSOCIATION (NPCA) CERTIFIED PLANT. ENTIRE PRECAST
BASE SHALL BE MANUFACTURED AT THE PLANT PER ASTM C478.
MAG "AA" 4000 PSI CONCRETE SHALL BE USED FOR PRECAST
MANHOLE BASES.
SPRING LINE OF CAST-IN-PLACE BELL SHALL STOP AT INSIDE FACE OF
MANHOLE.
JOINTS FOR BARREL SECTION SHALL BE TONGUE AND GROOVE TYPE.
ALL LIFTING HOLES SHALL BE SEALED WITH GROUT.
ALL PRECAST MANHOLE BASES SHALL BE PLACED ON 8" MINIMUM OF
ABC PER SECTION 702 COMPACTED TO 100% MAXIMUM DENSITY.
ALL MODIFICATIONS SHALL BE APPROVED BY THE ENGINEER.
MINIMUM WALL THICKNESS SHALL BE PER ASTM C478 (MIN 5").
REINFORCEMENT SHALL BE DESIGNED BY AN ARIZONA REGISTERED
PROFESSIONAL ENGINEER.
CHANNEL TRANSITION SHALL BE CONSTANT FROM INLET TO OUTLET
OF MANHOLE TO FACILITATE SMOOTH TRANSITIONS AND
ACCOMMODATE CORRESPONDING MANDREL.
THERE SHALL BE NO HARD CONNECTIONS (GROUTED) INTO THE
MANHOLE BASE UNLESS APPROVED BY THE ENGINEER.
ALL SEWER SERVICE CONNECTIONS SHALL HAVE THE SAME
CONNECTION TYPES IN THE PRECAST MANHOLE BASE.
ALL CORE HOLES INTO THIS STRUCTURAL PRECAST BASE SHALL BE
COATED WITH AN APPROVED COATING MATERIAL.
THE MANHOLE BOTTOM SHALL EXTEND OUTSIDE THE MANHOLE
WALL A MINIMUM 6" WIDE ON 48" BASES, 7" WIDE ON 60" BASES, AND
8" WIDE ON 72" BASES. EXTENDED BOTTOM SHALL BE A MINIMUM OF
5" THICK.
ALL PIPE CONNECTIONS SHALL BE IN COMPLIANCE WITH ASTM F477
OR ASTM C425. AN EXTRA STRENGTH VCP BELL WITH A
POLYURETHANE JOINT THAT MEETS ASTM C425 MAY BE USED WITH
VCP.
DIAMETER PER PLAN
PVC SDR-35 PVC SDR-35
NOT NEEDED
NOT NEEDED
DESIGNED BY:
DRAWN BY:
REVIEWED BY:
JOB. NO.
PROJ. NO.
SHEET
OF
DRAWING NO.
Tariq Tariq
Tariq Tariq
William O'Brien
T:\T17-001-2020 Nogales IOI 8 Laterals\AutoCAD\IOI-Laterals 100%.dwg
100% DESIGN
4-22-21
AutoCAD SHX Text
4" TYP.
AutoCAD SHX Text
8"MIN.
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
CLAY PIPE
AutoCAD SHX Text
OTHER PIPE TYPES
Ø7/8" DRILL AS 7/8" DRILL AS NECESSARY FOR MACHINING
CUT AND PLUG
ABANDONED PIPE
5 FEET MAX FROM
BUILDING.
1' GROUT FILL
SECTION OF
PIPE REMOVED
8" MIN.EXPANDABLE PLUG
WATERTIGHT CEMENT
NON-SHRIN…
This is the start of the file's text. The full file is on GovTribe.