This document contains a plumbing plan for a temporary kitchen renovation at Building 580 at Fort Leonard Wood, Missouri. The plan details new connections for domestic hot water, domestic cold water, and waste piping to support fixtures including a sink, ice maker, and existing faucet. Piping will be routed along walls and capped after project completion. Drain lines will connect to an existing 40mm line downstream of men's sinks. Installation will follow plumbing code and use PEX or equivalent tubing.

View the file

Other files

File Type Posted
W911S723R0001 Amendment 0004.pdf PDF
ATTACHMENT 18 - Contractors Price Schedule Worksheet.xlsx XLSX spreadsheet
W911S723R0001 Amendment 0003.pdf PDF
ATTACHMENT 3 - Davis-Bacon Act WD MO20230019 13 October 2023.pdf PDF
ATTACHMENT 4 - RFTOP Letter.pdf PDF
ATTACHMENT 20 Q and A - W911S7-23-R-0001.pdf PDF
ATTACHMENT 2 - Davis-Bacon Act WD MO20230005 13 October 2023.pdf PDF
W911S7-22-R-0001 Amendment 0002.pdf PDF
ATTACHMENT 19 - Davis-Bacon Act WD MO20230001 13 October 2023.pdf PDF
W911S7-23-R-0001 Amendment 00001.pdf PDF
ATTACHMENT 4 - RFTOP Letter.docx DOCX document
ATTACHMENT 10 - 8457_a4-DETAILS.pdf PDF
ATTACHMENT 15 - 8457_E3.pdf PDF
ATTACHMENT 8 - 8457_a2-FLOOR PLAN.pdf PDF
ATTACHMENT 7 - DEMOLITION PLAN.pdf PDF
ATTACHMENT 1 - FLW MATOC SOW.pdf PDF
ATTACHMENT 3 - MO20230005 14 July 2023.pdf PDF
ATTACHMENT 5 - Combined Specifications Kitchen 580.pdf PDF
ATTACHMENT 2 - Davis-Bacon Act WD MO20230005 8 September 2023.pdf PDF
ATTACHMENT 18 - Contractors Price Schedule Worksheet.xlsx XLSX spreadsheet
ATTACHMENT 13 - 8457_E1.pdf PDF
W911S7-23-R-0001 MATOC Solicitation - 13 Aug 2023.pdf PDF
ATTACHMENT 11 - 8457_a5-ELEVATIONS.pdf PDF
ATTACHMENT 6 - 8457_a0-TEMPORARY KITCHEN.pdf PDF
ATTACHMENT 14 - 8457_E2.pdf PDF
ATTACHMENT 12 - 8457_a6-ELEVATIONS (2).pdf PDF
ATTACHMENT 17 - 8457_m-M2.pdf PDF
ATTACHMENT 9 - 8457_a3-REFLECTED CEILING PLAN.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DW

UT SINK

REFRIGERATORS

MW

U T

T B

F

T

UTTB 6FT

MW

FE

UTTB 4FT

TEMPORARY KITCHEN

RANGE

FY

SCALE:

D E

S I G

N E

D

C H

E C

K E

D

S U

B M

I T

T E

D

A P

P R

O V

E D

D A

T E

R E

V I S

I O

N S

D I R

E C

T O

R A

E

O

F

P

U B

L I C

W

R

K S

F O

R

L

O

N A

R D

W

O

D

M

I S

S O

U R

I

D R

A W

N

DATE:

PROJECT NO:

DRAWING NO:

SHEET OF

D A

T E

M A

D E

A P

P R

O V

E D

J

B a l e s

C

E

D B

A

D

A V

I S

A

V

I S

J D

B

A L E

S

A

L O

P E

Z

T E

M P

O R

A R

Y

K

I T

C H

E N

P L

U M

B I N

G

P

L A

N

R E

N O

V A

K

I T

C H

N

B U

I L

D I N

G

AS SHOWN

07DEC22

M.0118951

FES 08369-1J

8457.12

M1 2

0 1' 2' 4'

SCALE: 1/2"=1'-0" (ANSI D)

N

TEMPORARY KITCHEN PLAN

PLUMBING SUPPLY AND WASTE

M1

GENERAL NOTES:

1. REFER TO ELECTRICAL, MECHANICAL, AND ARCHITECTURAL

SHEETS FOR ADDITIONAL INFORMATION.

2. VERIFY ALL PIPE SIZES AND DIMENSIONS IN THE FIELD PRIOR

TO ORDERING MATERIAL.

3. ADHERE TO CURRENT APPLICABLE CODE AND INDUSTRY BEST

PRACTICES.

NEW WORK NOTES:

1. INSTALL EQUIPMENT AS SHOWN IN ARCHITECTURAL,

MECHANICAL, AND ELECTRICAL DRAWINGS.

2. INSULATE EXPOSED WATER PIPING TO PREVENT CONDENSATE

AND/OR EXCESSIVE HEAT LOSS.

3. SUPPORT PIPING AT MANUFACTURERS SUGGESTED

INTERVALS ALONG WALL.

4. PEX OR EQUIVALENT IS ACCEPTABLE FOR TEMPORARY

INSTALLATION REQUIREMENTS.

5. DRAIN PIPING SHALL BE SCH40 PVC.

KEYED NOTES:

1. RUN NEW DHW AND DCW LINES ALONG WALL IN A NEAT AND

TIDY MANNER. CAP LINES BACK TO COPPER AND REPAIR ANY

PENETRATIONS AT CONCLUSION OF PROJECT. REPLACE

CEILING TILES AS NEEDED FOR CEILING PENETRATIONS.

2. SINGLE UNIT TO RECEIVE WATER FOR ICE MAKING.

3. ROUTE NEW DRAIN LINE TO EXISTING 40mm DRAIN LINE

DOWNSTREAM OF EXISTING MEN'S SINKS.

FIXTURE SCHEDULE

MARK ITEM MANUFACTURER MODEL NOTES

F1 SINK MUSTEE 27F

EXISTING FAUCET TO

BE UTILIZED

F1

20mm EXISTING DCW/DCW

20mm EXISTING DCW

1 1