Attachment 10 Elec 100_ 19-292.pdf

PDF 4 MB Posted

Attached to
Y1DA--635-414 Parking Garage 2 Construction Minor - OKC (VA-23-00002215)
Solicitation number
36C77623B0046
Issued by

About this file

This solicitation is for a construction project to build a new parking garage at the Oklahoma City VA Medical Center. Key requirements include constructing a new two-level parking garage with approximately 200 parking spaces, along with associated site work and utilities. The estimated value is $10-15 million. The period of performance is 730 calendar days from NTP. The solicitation was issued on July 6, 2022 by the VA Technology Acquisition Center with responses due by August 5, 2022. The contract is set aside for Service-Disabled Veteran-Owned Small Businesses. The selected contractor will be responsible for all construction in accordance with provided drawings, specifications and performance standards.

View the file

Other files

File Type Posted
2nd Visit Signed Sign in Sheet OKC Parking Garage 2.pdf PDF
36C77623B0046 0007.docx DOCX document
36C77623B0046 0006.docx DOCX document
36C77623B0046 0005.docx DOCX document
36C77623B0046 0004.docx DOCX document
Tech Questions Responses OKC Parking Garage Tracking Q _ A.pdf PDF
36C77623B0046 0003.docx DOCX document
36C77623B0046 0002.docx DOCX document
OKC DBA Wages Determination OKC County.pdf PDF
amendment Site visit Sheet 36C77623B0046 0001.pdf PDF
Site Visit signed Sign in Sheet OKC Parking Garage 2.pdf PDF
Signed Site visit Sheet 36C77623B0046 0001.pdf PDF
Attachment 13 - Contractor Safety - Environmental Form.docx DOCX document
Attachment 04 Struct 100_ 19-292.pdf PDF
Attachment 08 Plumb 100_ 19-292.pdf PDF
Attachment 11 Specs.pdf PDF
Attachment 07 FS 100_ 19-292.pdf PDF
Attachment 02 Civil 100_ 19-292.pdf PDF
Attachment 01 Gen 100_ 19-292.pdf PDF
Attachment 09 Mech 100_ 19-292.pdf PDF
Attachment 03 Land 100_ 19-292.pdf PDF
Attachment 06 Arch 100_ 19-292.pdf PDF
Attachment 15- Site Visit Instructions.docx DOCX document
36C77623B0046_1.docx DOCX document
Attachment 14 - Limitations on Subcontracting - Construction.docx DOCX document
Attachment 16- DBA Wages Determination.pdf PDF
Attachment 12 - Geotech Report.pdf PDF
Attachment 05 AP AW 100_ 19-292.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

L

SR SURFACE RACEWAY

SS STAINLESS STEEL

SSTV SECURITY SURVEILLANCE

TELEVISION

SSW SELECTOR SWITCH

STD STANDARD

SURF SURFACE MOUNTED

SW SWITCH

SWBD SWITCHBOARD

SYM SYMMETRICAL

SYS SYSTEM

TC TIMECLOCK

TEL TELEPHONE

TEL/DATA TELEPHONE/DATA

TERM TERMINAL

TGB TELECOMM GROUND BUS BAR

TMGB TELECOMM MAIN GROUND BUS BAR

TP TWISTED PAIR

TPS TWISTED PAIR SHIELDED

TR TAMPER RESISTANT,

TELECOMM ROOM

T-STAT THERMOSTAT

TTB TELEPHONE TERMINAL BOARD

TTC TELEPHONE TERMINAL CABINET

TV TELEVISION

TYP TYPICAL

UC UNDER COUNTER

UE UNDERGROUND ELECTRICAL

UG UNDERGROUND

UH UNIT HEATER

UL UNDERWRITER'S LABORATORY

UPS UNINTERRUPTIBLE POWER SUPPLY

UT UNDERGROUND TELEPHONE

UTP UNSHIELDED TWISTED PAIR

UTIL UTILITY

UV UNIT VENTILATOR OR

ULTRAVIOLET

V VOLT

VA VOLT-AMPERES

VERT VERTICAL

VFD VARIABLE FREQUENCY DRIVE

VOL VOLUME

W WATT

W/ WITH

WH WATER HEATER

WM WIRE MANAGEMENT

W/O WITHOUT

WP WEATHERPROOF

XFMR TRANSFORMER

XFR TRANSFER

ANGLE

@ AT

DELTA

' FEET

" INCHES

# NUMBER

Φ PHASE

C CENTER LINE

NEMA NATIONAL ELECTRICAL

MANUFACTURER'S ASSOCIATION

NFDS NON-FUSED SAFETY DISCONNECT

SWITCH

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NORMALLY OPEN

NTS NOT TO SCALE

NVR NETWORK VIDEO RECORDER

OC ON CENTER

OD OUTSIDE DIAMETER

OH OVERHEAD

OIT OFFICE OF INFORMATION

TECHNOLOGY

OL OVERLOAD

PA PUBLIC ADDRESS

PACS PHYSICAL ACCESS CONTROL SYSTEM

PAMN PUBLIC ADDRESS AND MASS

NOTIFICATION SYSTEM

PB PULL BOX OR PUSHBUTTON

PCB POLYCHLORINATED BIPHENYL

PC PHOTOELECTRIC CELL

PDU RACK POWER DISTRIBUTION UNITS

PED PEDESTAL

PEND PENDANT

PF POWER FACTOR

PH PHASE

PIR PASSIVE INFRARED

PIV POST INDICATING VALVE

PNL PANEL

POE POWER-OVER-ETHERNET

PR PAIR

PRI PRIMARY

PROJ PROJECTION

PT POTENTIAL TRANSFORMER

PVC POLYVINYL CHLORIDE (CONDUIT)

PWR POWER

QTY QUANTITY

RCP REFLECTED CEILING PLAN

RCPT RECEPTACLE

REQD REQUIRED

RGS RIGID GALVANIZED STEEL

RM ROOM

RMS ROOT MEAN SQUARE

RTU ROOF TOP UNIT

RX REQUEST TO EXIT

SC SURFACE CONDUIT

SEC SECONDARY

SEP SERVICE ENTRANCE PROTECTION

SF SQUARE FEET/FOOT

SHT SHEET

SI INTERNATIONAL SYSTEM OF UNITS

SIM SIMILAR

SM SINGLE MODE FIBER

S/N SOLID NEUTRAL

SPEC SPECIFICATION

SPKR SPEAKER

SP SPARE

1P 1 POLE (2P, 3P, 4P, ETC.)

1PH 1 PHASE

2/C TWO-CONDUCTOR (3/C, 4/C, ETC.)

2W TWO-WIRE (3W, 4W, ETC.)

3PH 3 PHASE

A AMPERE

AAP ALARM ANNUNCIATOR PANEL

AC ABOVE COUNTER

AIR CONDITIONER

ALTERNATING CURRENT

ACC ACCESSIBLE

ACLG ABOVE CEILING

ADO AUTOMATIC DOOR OPENER

A/E ARCHITECT/ENGINEER

AF AMP FRAME

AFC AVAILABLE FAULT CURRENT (KILOAMPS)

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFI ARC FAULT CIRCUIT INTERRUPTER

AHJ AUTHORITY HAVING JURISDICTION

AHU AIR HANDLING UNIT

AIC AMPERE INTERRUPTING CAPACITY

AL ALUMINUM

ALT ALTERNATE

AMP AMPERE

APPROX APPROXIMATELY

ARCH ARCHITECT, ARCHITECTURAL

AT AMP TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIO VISUAL

AWG AMERICAN WIRE GAUGE

BAS BUILDING AUTOMATION SYSTEM

BATT BATTERY

BC BARE COPPER

BD BOARD

BLDG BUILDING

BMS BUILDING MANAGEMENT SYSTEM

BYP BYPASS

C CONDUIT

CAB CABINET

CALC CALCULATED

CAP CAPACITY

CAT CATALOG, CATEGORY

CATV COMMUNITY ANTENNA TELEVISION

CB CIRCUIT BREAKER

CCR CONTROL CONTACTOR

CCTV CLOSED CIRCUIT TELEVISION

cd CANDELA

CD CONSTRUCTION DOCUMENTS

CKT CIRCUIT

CLG CEILING

CO CONTRACTING OFFICER

COAX COAXIAL CABLE

COMM COMMUNICATION

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUATION OR CONTINUOUS

CONTR CONTRACTOR

COORD COORDINATE

COR CONTRACTING OFFICER'S

REPRESENTATIVE

CPT CONTROL POWER TRANSFORMER

CRI COLOR RENDERING INDEX

CT CURRENT TRANSFORMER

CTV CABLE TELEVISION

CTR CENTER

CU COPPER

CU FT CUBIC FEET

dB DECIBEL

DB DIRECT BURIAL

DC DIRECT CURRENT,

DOOR CONTACT SWITCH

DEG C DEGREES CELSIUS

DEG F DEGREES FAHRENHEIT

DEMO DEMOLISH/DEMOLITION

DEPT DEPARTMENT

DIA DIAMETER

DISC DISCONNECT

DIST DISTRIBUTION

DN DOWN

DO DOOR OPERATOR

DS SAFETY DISCONNECT SWITCH

DT DOUBLE THROW

DVR DIGITAL VIDEO RECORDER

DWG DRAWING

EC ELECTRICAL CONTRACTOR

ECB ENCLOSED CIRCUIT BREAKER

EEB EMERGENCY EXIT BUTTON

EG EQUIPMENT GROUND

EL ELECTRIC STRIKE

ELEC ELECTRIC, ELECTRICAL

ELEV ELEVATOR

EM EMERGENCY

EMI ELECTROMAGNETIC INTERFERENCE

EMS ENERGY MANAGEMENT SYSTEM

EMT ELECTRICAL METALLIC TUBING

EPO EMERGENCY POWER OFF

EQUIP EQUIPMENT

ESMT EASEMENT

ETR EXISTING TO REMAIN

EWH ELECTRIC WALL HEATER

ELECTRIC WATER HEATER

EX EXISTING

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FAP FIRE ALARM PANEL

FC FOOTCANDLE

FCU FAN COIL UNIT

FIXT FIXTURE

FLR FLOOR

FO FIBER OPTIC

FUDS FUSED SAFETY DISCONNECT SWITCH

FVR FULL VOLTAGE REVERSING

FVNR FULL VOLTAGE NON-REVERSING

GAL GALLON

GALV GALVANIZED

GC GENERAL CONTRACTOR

GEN GENERATOR

GFI GROUND FAULT CIRCUIT INTERRUPTER

GND GROUND

GRS GALVANIZED RIGID STEEL (CONDUIT)

GYP BD GYPSUM BOARD

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HT HEIGHT

HTR HEATER

HV HIGH VOLTAGE

HVAC HEATING, VENTILATING AND AIR

CONDITIONING

IES ILLUMINATION ENGINEERING SOCIETY

IG ISOLATED GROUND

IMC INTERMEDIATE METAL CONDUIT

IR INFRARED

IT INTERCOMMUNICATION

I/W INTERLOCK WITH

IWH INSTANTANEOUS WATER HEATER

J-BOX JUNCTION BOX

KV KILOVOLT

KVA KILOVOLT-AMPERE

KVAR KILOVOLT-AMPERE REACTIVE

KW KILOWATT

KWH KILOWATT HOUR

LED LIGHT-EMITTING DIODE

LF LINEAR FEET/FOOT

LM LUMEN

LRA LOCKED ROTOR AMPS

LT LIGHT

LTG LIGHTING

LTNG LIGHTNING

LV LOW VOLTAGE

MATV MASTER ANTENNA TELEVISION SYSTEM

MAX MAXIMUM

MC MECHANICAL CONTRACTOR

METAL-CLAD (CONDUIT)

MCA MINIMUM CIRCUIT AMPACITY

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MLO MAIN LUGS ONLY

MM MULTI MODE FIBER

MSC MULTI SENSOR CAMERA(S)

MT MOUNT

MTR MOTOR, MOTORIZED

MTS MANUAL TRANSFER SWITCH

NA NOT APPLICABLE

NAC NETWORK APPLIANCES CONTROL PANEL

NC NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

A1 b

E1 c d

T1

'LPN'

THE LIGHTING FIXTURE TYPE IS INDICATED BY AN UPPER CASE LETTER OR AN UPPER

CASE LETTER AND NUMBER.

THE SWITCH DESIGNATION (IF NEEDED) IS INDICATED BY A LOWER CASE LETTER.

EXAMPLE: LIGHTING FIXTURE TYPE 'A1' IS CONTROLLED BY SWITCH 'b'.

EXIT SIGNS: STEM INDICATES WALL MOUNTING. NO STEM INDICATES CEILING

MOUNTING. SHADED AREA INDICATES ILLUMINATED FACE(S). ARROW INDICATES

DIRECTIONAL ARROW ON ILLUMINATED FACE(S).

DEVICES: THE SWITCH DESIGNATION IS INDICATED BY A LOWER CASE LETTER.

THE CONTROL DEVICE DESIGNATION IS INDICATED BY A LOWER CASE LETTER.

TRANSFORMERS: THE TRANSFORMER TYPE IS INDICATED BY A NUMBER

FOLLOWING THE UPPER CASE LETTER 'T'. SEE THE TRANSFORMER SCHEDULE OR

THE SINGLE LINE DIAGRAM FOR THE TRANSFORMER DESCRIPTION AND

REQUIREMENTS.

PANELBOARDS: PANELBOARD DOORS MAY BE SHOWN TO INDICATE OPENING

SIDE OF RECESSED PANELBOARDS. SEE PANELBOARD IDENTIFICATION FOR

DESIGNATION CODES.

SHEET KEY NOTE: SEE THE SHEET KEY NOTES ON THAT SHEET FOR THE NOTE

NUMBER INDICATED IN THE HEXAGON.

HOME RUN TO BRANCH CIRCUIT PANEL: THE PANEL DESIGNATION AND CIRCUIT

DESIGNATION ARE SHOWN ADJACENT TO THE HOME RUN ARROW.

CIRCUIT BREAKER SIZES (AMPS/NUMBER OF POLES) ARE SHOWN IN THE PANEL

SCHEDULE WITH THE CORRESPONDING PANEL AND CIRCUIT DESIGNATION.

SYMBOL NOTATIONS: UPPER CASE LETTERS ADJACENT TO SYMBOLS INDICATE

A UNIT TYPE. SEE APPROPRIATE SCHEDULE OR SPECIFICATIONS.

'LPN'-1,3,5

EXAMPLE 1: WALL MOUNTED EXIT SIGN TYPE 'E1' WITH SINGLE FACE

AND DIRECTIONAL ARROW.

EXAMPLE 2: CEILING MOUNTED EXIT SIGN TYPE 'E2' WITH DOUBLE

FACE AND DIRECTIONAL ARROWS.

E2

EXAMPLE: SPLIT DUPLEX RECEPTACLE; ONE RECEPTACLE OUTLET IS

CONTROLLED BY SWITCH 'c'.

EXAMPLE: SINGLE POLE SWITCH 'd' TO CONTROL LIGHTING FIXTURES INDICATED BY 'd'.

EXAMPLE: TRANSFORMER TYPE 'T1'.

EXAMPLE: HOME RUN TO PANELBOARD 'LPN'; CIRCUITS 1, 3, 5.

# DEMOLITION KEY NOTE: SEE THE SHEET KEY NOTES ON THAT SHEET FOR THE

NOTE NUMBER INDICATED IN THE SQUARE.

1. ALL ELECTRICAL DEVICES, FIXTURES, EQUIPMENT AND FEEDERS SHALL BE INSTALLED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, THE MANUFACTURER'S RECOMMENDED PROCEDURES, ALL APPLICABLE LOCAL AND STATE CODES, AMERICANS WITH DISABILITIES ACT AND WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND VA

STANDARDS.

2. PROVIDE ADDITIONAL SUPPORT FOR DEVICES, FIXTURES, EQUIPMENT AND FEEDERS WHERE THE BUILDING

CONSTRUCTION IS NOT SUITABLE FOR DIRECT MOUNTING.

3. FIRESTOP, DRAFTSTOP, SMOKESTOP AND/OR PROTECT THE ANNULAR SPACE AROUND ALL PENETRATIONS THROUGH WALLS, PARTITIONS, FLOORS, CEILING, AND ROOFS IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL

ELECTRICAL CODE, UL LISTING REQUIREMENT AND THE APPLICABLE BUILDING CODES.

4. VERIFY CEILING SYSTEMS AND PROVIDE MOUNTING ACCESSORIES, TRIMS AND ALL REQUIRED MOUNTING HARDWARE TO

SUIT THE PARTICULAR INSTALLATION.

5. PROTECT EXISTING UNDERGROUND AND BUILDING INTERIOR UTILITIES DURING CONSTRUCTION.

6. BRANCH CIRCUIT CONDUCTORS SHALL BE 12 AWG COPPER MINIMUM.

7. COORDINATE ANY AND ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION SO AS TO AVOID CONFLICT DURING

CONSTRUCTION.

8. ALL PANELS SHALL HAVE TYPED, COMPLETED DIRECTORIES INDICATING EQUIPMENT SERVED AND ROOM NUMBER (AS INDICATED ON FINAL BUILDING ROOM SIGNAGE) OF EQUIPMENT LOCATION, OR SPARE, OR SPACE.

9. MANUFACTURER'S NAME AND MODEL NUMBER ARE GIVEN FOR DESCRIPTIVE PURPOSES, TO INDICATE A QUALITY STANDARD, AND ARE NOT INTENDED TO LIMIT PRODUCTS TO A PARTICULAR MANUFACTURER. PRODUCTS DEEMED EQUAL AND APPROVED BY THE DESIGNER WILL BE ACCEPTED. ALL PRODUCTS MUST COMPLY WITH "BUY AMERICAN ACT".

10. ALL FEEDERS AND CIRCUITRY SHALL BE TORQUED PER THE PANEL, BREAKER, AND/OR PARTICULAR EQUIPMENT

MANUFACTURER'S SPECIFICATIONS.

11. CIRCUITRY TO SWITCHES, RECEPTACLES, AND ALL OTHER DEVICES SHALL BE TERMINATED ON THE DEVICE'S SCREW

TERMINALS.

12. MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, OUTLET, FIXTURE, OR EQUIPMENT UNLESS NOTED

OTHERWISE.

13. ALL WIRE TERMINATIONS SHALL BE RATED FOR 75 DEGREES C.

14. ALL CONDUCTORS SHALL HAVE THHN/THWN INSULATION, UNLESS OTHERWISE NOTED.

15. ALL CONDUIT SHALL BE RGS OR EMT UNLESS OTHERWISE NOTED. FMC CONDUIT SHALL BE USED ON VIBRATING EQUIPMENT (MAXIMUM LENGTH OF 6 FEET). PVC SHALL BE USED FOR UNDERGROUND CONDUIT OR WHERE CONCRETE- ENCASED. WHERE VIBRATING EQUIPMENT IS LOCATED OUTSIDE, LFMC CONDUIT SHALL BE USED (MAXIMUM SIX FEET) FOR

FINAL CONNECTIONS.

16. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT SHALL BE LABEL LISTED BY AN APPROVED THIRD

PARTY TESTING AGENCY.

17. FOR ALL LED FIXTURES, THE FIXTURE MUST BE CAPABLE OF SELF-RESETTING TO THE SWITCHED/CONTROLLED STATE DURING ANY FLUCTUATION IN POWER SUPPLY WHERE AUTOMATIC PROTECTIVE MEASURES DISABLE THE LED LAMPS.

PROVIDE A LETTER OR STATEMENT FROM THE MANUFACTURER, OR OTHER ACCEPTABLE PROOF, THAT ALL LED FIXTURES, WITH OR WITHOUT BROWNOUT PROTECTION, WILL RETURN TO THE SWITCHED/CONTROLLED STATE AUTOMATICALLY.

PROVIDE STATEMENT WITH THE FIXTURE SUBMITTALS.

18. IN CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG THE CONTRACT DRAWINGS, THE BETTER QUALITY, MORE STRINGENT REQUIREMENTS OR GREATER QUANTITY OF WORK , AS DETERMINED BY THE GOVERNMENT, SHALL BE

PROVIDED.

19. COMPRESSION COUPLINGS SHALL BE USED. NO SET SCREW FITTINGS ARE ALLOWED.

20. MINIMUM CONDUIT SIZE TO BE USED IS 1 1/4".

21. GENERAL CONTRACTOR TO RELOCATE MEDIUM VOLTAGE LINE - PAID FOR BY AN ALLOWANCE UNDER THIS CONTRACT.

COORDINATE WITH UTILITY AND VA CONTRACTING OFFICER OR CONTRACTING OFFICER'S REPRESENTATIVE.

120V DUPLEX RECEPTACLE

120V DUPLEX RECEPTACLE EMERGENCY OUTLET

AND COVER PLATE SHALL BE RED IN COLOR

120V QUADRUPLEX RECEPTACLE

120V QUADRUPLEX RECEPTACLE EMERGENCY

OUTLET AND COVER PLATE SHALL BE RED IN COLOR

SYMBOL HEIGHT DESCRIPTION

18"

18"

18"

18"

SPECIAL RECEPTACLE

208V DUPLEX RECEPTACLE18"

18"

RECEPTACLE MODIFIERS:

AC: 3" ABOVE COUNTERTOP/BACKSPLASH

GFI: GROUND FAULT CURRENT INTERRUPTER

WP: WEATHERPROOF ENCLOSURE

DED: DEDICATED CIRCUIT

JUNCTION BOX, WALL MOUNTED, PURPOSE AS NOTED

DISCONNECT SWITCH NON-FUSED

DISCONNECT SWITCH FUSED

SINGLE POLE WALL SWITCH: 48" AFF STANDARD UNO

AS

NOTED

72" TOP

72" TOP

SWITCH MODIFIERS:

M: MOTOR-RATED

48"

ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.

TOP: HEIGHT TO TOP OF DEVICE

ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.

EQUIPMENT CONNECTION

AS

NOTED

E

CLNG

J

J

J

JUNCTION BOX, CEILING MOUNTED, PURPOSE AS

NOTED

JUNCTION BOX, FLOOR MOUNTED, PURPOSE AS

NOTED

PARKING GARAGE LIGHT

4' STRIP LIGHT

SYMBOL

HEIGHT

AFF * DESCRIPTION

--- 4' LINEAR SURFACE MOUNTED

WALL PACK

10'-0"

BOTTOM

LIGHTED BOLLARD---

EXIT SIGN - WALL MOUNTED

EXIT SIGN - CEILING MOUNTED---

7'-5"

BOTTOM

EMERGENCY LIGHT BATTERY

OPERATED - WALL MOUNTED

7'-6"

CENTER

4' LINEAR - WALL MOUNTED

7'-0"

CENTER

SINGLE POLE WALL SWITCH

SWITCH MODIFIERS:

OS: OCCUPANCY SENSOR, DUAL TECHNOLOGY

VS: VACANCY SENSOR, DUAL TECHNOLOGY

D: LINE VOLTAGE DIMMER

T: DIGITAL TIMER

K: KEYED

3: 3 WAY

48"

CENTER

OCCUPANCY SENSOR, DUAL

TECHNOLOGY - CEILING MOUNTED

OCCUPANCY SENSOR, DUAL

TECHNOLOGY - WALL/CORNER MOUNTED

OS

OS

* - ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE

LISTED HERE.

LIGHT LEVEL SENSOR, SINGLE ZONE

DIMMING CLOSED LOOP - CEILING MOUNTED

---LS

TRIPLE HEAD AREA LIGHT - POLE MOUNTEDPOLE

DUAL HEAD AREA LIGHT - POLE MOUNTEDPOLE

SINGLE HEAD AREA LIGHT - POLE MOUNTEDPOLE

PHOTOCELLPC

1. PROVIDE COMMUNICATIONS DEVICES AND EQUIPMENT IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, MANUFACTURER'S RECOMMENDED PROCEDURES, ALL APPLICABLE LOCAL AND STATE CODES, AMERICANS WITH DISABILITIES ACT, LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, BICSI STANDARDS, AND VA

STANDARDS.

2. PROVIDE ADDITIONAL SUPPORT FOR DEVICES AND EQUIPMENT WHERE BUILDING CONSTRUCTION IS NOT

SUITABLE FOR DIRECT MOUNTING.

3. FIRESTOP, DRAFTSTOP, SMOKESTOP OR PROTECT ANNULAR SPACE AROUND PENETRATIONS THROUGH WALLS, PARTITIONS, FLOORS, CEILINGS, AND ROOF IN ACCORDANCE WITH REQUIREMENTS OF NFPA 70, UL

LISTING REQUIREMENT AND APPLICABLE BUILDING CODES.

4. PROVIDE CABLING THAT COMPLIES WITH LATEST EDITION OF TELECOMMUNICATIONS DISTRIBUTION

METHOD MANUAL AND ANSI/TIA/EIA PUBLICATIONS.

5. COMPLY WITH ANSI/TIA/EIA 758 AND 607B OR 607A - GROUNDING AND BONDING REQUIREMENTS FOR

TELECOMMUNICATIONS IN COMMERCIAL BUILDING.

6. COMPLY WITH ANSI/TIA/EIA 568B - COMMERCIAL BUILDING TELECOMMUNICATIONS WIRING STANDARD.

7. COMPLY WITH ANSI/TIA/EIA 569B - COMMERCIAL BUILDING STANDARD FOR TELECOMMUNICATIONS

PATHWAYS AND SPACES.

8. COMPLY WITH NFPA 70 NATIONAL ELECTRICAL CODE.

9. COMPLY WITH NFPA 99 HEALTHCARE FACILITIES CODE.

10. COMPLY WITH NFPA 101 LIFE SAFETY CODE.

11. COORDINATE WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION.

12. MANUFACTURER'S NAME AND MODEL NUMBER ARE GIVEN FOR DESCRIPTIVE PURPOSES, TO INDICATE A QUALITY STANDARD, AND ARE NOT INTENDED TO LIMIT PRODUCTS TO A PARTICULAR MANUFACTURER.

PRODUCTS DEEMED EQUAL AND APPROVED BY THE COR WILL BE ACCEPTABLE. COMPLY WITH "BUY

AMERICAN ACT".

13. MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, BOXES, OUTLET, OR EQUIPMENT UNLESS

NOTED OTHERWISE.

14. PROVIDE RGS OR EMT CONDUIT UNLESS OTHERWISE NOTED.

15. PROVIDE MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT LABEL LISTED BY APPROVED THIRD PARTY

TESTING AGENCY.

16. NOTIFY COR REGARDING DISCREPANCY BETWEEN PLANS AND SPECIFICATIONS FOR CLARIFICATION. THE

MORE STRINGENT OF THE THEM SHALL TAKE PRECEDENCE.

17. FOR LOCATION (CORRIDOR, ROOM OR ADJACENT SPACE) WITH TWO OR MORE VISIBLE FIRE ALARM NOTIFICATION APPLIANCES WITHIN THE FIELD OF VIEW, PROGRAM VISIBLE TO FLASH IN SYNCHRONIZATION.

18. PROVIDE TIA/EIA CAT 6A COPPER OUTLETS AND CONNECTORS.

19. ALL WORK AREA OUTLETS SHALL BE 8 PIN, CAT 6A KEYSTONE JACK WIRED PER T568A OR T568B AS

DIRECTED BY THE VA COR.

20. LABEL DEVICES IN ACCORDANCE WITH LATEST ANSI/TIA 606A OR 606B EDITION AS WELL AS THE STANDARDS

SET FORTH BY THE VA HOSPITAL OIT.

21. PROVIDE A MINIMUM OF 12" CLEARANCE ABOVE THE CABLE TRAY PER TIA/EIA 569.B PARAGRAPH 4.5.6.2.

22. VA WILL CONDUCT A WAP SURVEY AND PROVIDE THE SURVEY TO THE CONTRACTOR. INSTALL CABLING AND

EQUIPMENT IN ACCORDANCE WITH THE SURVEY. COORDINATE WITH COR/OIT.

23. ALL CABLING SHALL BE INSTALLED IN CONDUIT.

DATA OUTLET - 2-4 PR UTP

SYMBOL HEIGHT DESCRIPTION

18"

DATA OUTLET - 4-4 PR UTP18"

DATA OUTLET - 1-4 PR UTP

TELCO OUTLET - 1-4 PR UTP

18"

48"

WIRELESS ACCESS POINT - 2-4 PR UTP

WALL PHONEW 48"

CEILING

ELECTRONIC LOCKING MECHANISM

DOOR CONTACT

REQUEST FOR EXIT SENSOR

CARD READER

(K - KEYPAD)

48"CR

ES

DC

RX

DOOR

DOOR

ABOVE

DOOR

PHYSICAL ACCESS CONTROL SYSTEMPACS 6' TO TOP

ELECTRONIC PANIC HARDWAREEP

DO DOOR OPERATOR

DOOR

DOOR

48" EMERGENCY EXIT BUTTON TO RELEASE DOOR (EEB)

SSTV DOME CAMERA FIXED

SSTV DOME CAMERA MULTI SENSOR - PANORAMIC

FOUR POST OIT EQUIPMENT RACK

SSTV EQUIPMENT CABINETSSTV

LADDER CABLE TARY

GROUND BUS

FLOOR

FLOOR

ABOVE

CEILING

18"

4'x8'x3/4" FIRE RATED TTB8"

FLOOR TWO POST OIT EQUIPMENT RACK

CEILING MOUNTED SPEAKERSCEILING

WALL MOUNTED SPEAKERS96"

S

S

ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.

ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.

SEE DRAWINGS FOR MORE INFORMATION.

NOTE: NOT ALL SYMBOLS ARE USED.

MS

F

48" AUTOMATIC DOOR OPENERADO

EMERGENCY BLUE LIGHT PHONE

WALL MOUNTED

EMERGENCY BLUE LIGHT PHONE

PEDESTAL MOUNTED

48" B

B

SYMBOL HEIGHT DESCRIPTION

ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.

TOP: HEIGHT TO TOP OF DEVICE

ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.

FIRE ALARM SMOKE DETECTOR

FIRE ALARM HEAT DETECTOR

FIRE ALARM PULL STATIONF

F

FIRE ALARM SPEAKER

FIRE ALARM STROBE

FIRE ALARM PULL SPEAKER AND STROBE

42"

90"

90"

90"

FIRE ALARM CONTROL PANELFACP

XX - CANDELA

XX - CANDELA

XX - WATTAGEF

S

F

S

FIRE ALARM ANNUNCIATOR PANELFAA

72"

72"

SD

HD

FLOW SWITCH WITH ADDRESSABLE MONITOR MODULE

TAMPER SWITCH WITH ADDRESSABLE MONITOR MODULE

SYMBOL HEIGHT DESCRIPTION

1. PROVIDE FIRE ALARM SYSTEM AND COMPONENTS COMPLYING WITH THE LATEST:

A. NFPA 13- STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS.

B. NFPA 14- STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEM.

C. NFPA 20- STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION.

D. NFPA 70 NATIONAL ELECTRICAL CODE.

E. NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE.

F. NFPA 90A STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS.

G. NFPA 101 LIFE SAFETY CODE.

H. VA FIRE PROTECTION DESIGN MANUAL.

I. ANSI S3.41 AUDIBLE EMERGENCY EVACUATION SIGNAL.

2. FIRE ALARM SYSTEM SHALL COMPLY WITH FACTORY MUTUAL RESEARCH CORPORATION (FM).

3. PROVIDE FIRE ALARM WIRING IN CONDUIT, FACTORY PAINTED RED.

4. THE FIRE ALARM SYSTEM VENDOR/CONTRACTOR SHALL TERMINATE, TEST AND PROGRAM ALL NEW FIRE ALARM DEVICES.

COORDINATE WITH COR.

5. CONNECT SPRINKLER SYSTEM SUPERVISORY DEVICES TO THE FIRE ALARM SYSTEM. COORDINATE LOCATION WITH THE

SPRINKLER CONTRACTOR.

6. PROVIDE RELAY CONTROL MODULES FOR PACS, COORDINATE WITH PHYSICAL ACCESS CONTROL SYSTEM (PACS), CONTRACTOR AND COR.

7. THE OPERABLE PART OF A MANUAL ACTUATED ALARM INITIATING DEVICE SHALL BE NOT LESS THAN 42" (1.07M) AND NOT

MORE THEN 48" (1.22M) FROM FINISH FLOOR.

8. ALL FIRE ALARM DEVICES IN THE PARKING GARAGE SHALL BE WEATHER PROOF.

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/1

/2

:4

:3

P M

C U s e rs

\a m a s o n

\D o c u m e n ts

\E

-2

-O

K C

P a rk in g G a ra g e a m a s o n a c g -p a .c o m

.r v t

E-001

ELECTRICAL GENERAL NOTES,

SYMBOL LEGENDS, AND

ABBREVIATIONS

1 16KLC

PARKING GARAGE 2

921 NE 13TH STREET

OKLAHOMA CITY, OK 73104

JULY 8, 2022

100% CONSTRUCTION DOCUMENTS

635-41419-292

N/A

JKM

ELECTRICAL AND TECHNOLOGY ABBREVIATIONS LIST

ELECTRICAL SYMBOL NOTES

ELECTRICAL GENERAL NOTES

ELECTRICAL SYMBOL LEGENDLIGHTING SYMBOL LEGEND

TECHNOLOGY GENERAL NOTES

TECHNOLOGY SYMBOL LEGEND

FIRE ALARM SYMBOL LEGEND

FIRE ALARM GENERAL NOTES

DocuSign Envelope ID: DE6B1966-C688-4097-B859-109EA506307E

7/6/2022

DN

PROPOSED

PARKING GARAGE

LP LP

LP

LP

LP

LP

L P

E T

E T

E T

E T

E T

E T

S W G R

E

E

P

LB

P

LB

B u s h

B u s h

E le c

P

LB

E le c

P

LB

E le c

P

LB

E le c

P

LB

E le c

P

LB

E le c

P

LB

E le c

P

LB

E le c

P

LB

E le c

P

LB

C o m m s

C o m m

P

LB

C o m m

P

LB

C o m m s

P

LB

C o m m s

P

LB

In d ia n

N a tio n s

T e le

In d ia n

N a tio n

T e le

C o m m s

P

LB

E

J

PC

CR

CRJ

E E

E

M

M

E

E

E

E

E

NEW PAD

MOUNTED

SERVICE

TRANSFORMER

P1

P1

NEW

GENERATOR

IT

ELEC

SECURITY

FACP

NEW

SECTIONALIZING

SWITCH

EXISTING

MEDIUM

VOLTAGE

SWITCHGEAR

'H1'- 2

PANEL 'GS'

PACS

'GS'- 1,3,5

'H1'- 23

WP

WP

'E1L'- 38,40,42

'E1L'- 19

'E1L'- 21

'GS'- 13,15,17

'GS'- 19,21,23

'GS'- 25,27,29

'E1L'- 37,39,41

'GS'- 7,9,11

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/1

/2

:4

:0

P M

C U s e rs

\a m a s o n

\D o c u m e n ts

\E

-2

-O

K C

P a rk in g G a ra g e a m a s o n a c g -p a .c o m

.r v t

ES101

ELECTRICAL SITE PLAN

2 16KLC

PARKING GARAGE 2

921 NE 13TH STREET

OKLAHOMA CITY, OK 73104

JULY 8, 2022

100% CONSTRUCTION DOCUMENTS

635-41419-292

N/A

JKM

Scale: No Scale

ELECTRICAL SITE PLAN

N

SCOPE OF WORK

KEY PLAN

SCALE: NO SCALE

AREA OF WORK

N O

R T

H0 4 8 16

A. ALL EXTERIOR LIGHT FIXTURES SHALL BE

CONTROLLED BY INTEGRAL PHOTOCELLS.

B. FOR ANY ITEMS WHICH CROSS OR APPROCH THE

OG&E RELOCATED UTILITY LINE, A MINIMUM OF

24" SEPARATION, HORIZONTAL OR VERTICAL,

MUST BE MAINTAINED FROM THIS RELOCATED

LINE.

1 CAMERA COVERING TRANSFORMER.

REFERENCE E-101.

2 PROVIDE TELECOM HANDHOLE. SEE DETAIL

11/E-502.

3 SEE ES102 FOR MORE INFORMATION.

4 PROVIDE TWO 4" CONDUITS WITH FIBER FOR

DATA AND PACS. SEE RISER DETAIL 3/E-503

FOR MORE INFORMATION.

5 PROVIDE TWO 2" CONDUITS.FOR FIRE ALARM

FIBER LOOP. SEE DETAIL 1/E-503 FOR MORE

INFORMATION.

6 PROVIDE MEDIUM VOLTAGE UNDERGROUND

500 kCMIL 15kV RATED FEEDER FROM

MEDIUM VOLTAGE SWITCHGEAR, CONCRETE

ENCASED IN 3" CONCRETE ENCASEMENT

(TWO 4" CONDUITS, ONE IS SPARE)

7 PROVIDE TWO 4" CONDUITS WITH

PULLCORDS STUBBED OUT 5'-0" FROM THE

SECTIONALIZING SWITCH FOR FUTURE.

8 PROVIDE MEDIUM VOLTAGE UNDERGROUND

500 kCMIL 15kV RATED FEEDERS IN

CONDUITS, TWO 4" CONDUITS (ONE SPARE)

TO SERVE NEW PAD MOUNTED

TRANSFORMER.

9 LOCATION OF GUARD SHACK.

10 LOCATION OF GATE CONTROLLER. PROVIDE

120V EMERGENCY POWER FROM PANEL ''GS'.

VERIFY REQUIREMENTS WITH

MANUFACTURER.

11 NEW CARD READER ON A PEDESTAL FOR THE

GATE. RUN 1" CONDUIT WITH CABLING TO

THE PACS PANEL. PEDESTAL SHALL BE 48"

HEIGHT, B.O.D.: ZORO GG33430I OR EQUAL.

12 PROVIDE ONE 2" CONDUIT WITH CABLING.

13 AUTOMATIC RETRACTABLE BOLLARDS;

208V/3PH, 5 HP; PROVIDE 3-8 AWG, 8 AWG EG

IN 1" CONDUIT.

14 EXISTING UNDERGROUND MEDIUM VOLTAGE

UTILITY LINE. GC TO RELOCATE MEDIUM

VOLTAGE LINE – PAID FOR BY AN

ALLOWANCE UNDER THIS CONTRACT.

COORDINATE WITH UTILITY AND VA CO/COR.

15 PROPOSED ROUTE OF NEW UNDERGROUND

MEDIUM VOLTAGE UTILITY DUCT BANK. SEE

CIVIL DRAWING CU101. GC TO RELOCATE

MEDIUM VOLTAGE LINE – PAID FOR BY AN

ALLOWANCE UNDER THIS CONTRACT.

COORDINATE WITH UTILITY AND VA CO/COR.

16 PROVIDE 1" CONDUIT WITH CONTROL CABLES

FROM CONTROL PANEL IN GUARD SHACK TO

RETRACTABLE BOLLARDS. VERIFY

REQUIRMENTS WITH SYSTEM

MANUFACTURER.

17 PROVIDE AND INSTALL LICENSE PLATE

RECOGNITION (ALPR) MULTISENSOR CAMERA

ON LPR POLE. COORDINATE EXACT

MOUNTING HEIGHT AT TIME OF

INSTALLATION. CAMERA SHALL BE INSTALLED

AS THIRD AUTHENTICATION IN THE TRIPLE

AUTHENTICATION PROCESS. RUN CONDUIT

AND WIRE TO GUARD SHACK. SEE DETAIL 7

ON E-503.

18 PROVIDE AND INSTALL ACCESS CONTROL TO

THE GATE ARM CONTROL SYSTEM AND

INTEGRATE WITH THE OPERATION

CONTROLS. INTEGRATIONS SHALL ALLOW

THE ACCESS CONTROL SYSTEM TO CONDUCT

THE FOLLOWING: POSITION MONITORING;

REMOTE OPEN; OPEN SCHEDULE, MAIN GATE

STATE FOR SCHEDULED PERIOD AND OPEN

ON AUTHORIZED TRIPLE AUTHENTICATION.

19 PROVIDE CIRCUIT FOR LIGHTED BOLLARDS.

PROVIDE PHOTOCELL FOR BOLLARD

CONTROL. COORDINATE SPECIFICATIONS

AND REQUIREMENTS WITH CIVIL.

20 POWER FOR GENERATOR FUEL RETURN

PUMP DTRP-1. PROVIDE FUSIBLE NEMA 3R

RATED DISCONNECT MOUNTED ON SELF

SUPPORTING ANGLE IRON FRAME NEAR

GENERATOR.

21 SEE DETAIL 12/E-501.

22 EXISTING POWER. SECURE MEDIUM VOLTAGE

SWITCHGEAR. UTILIZE ONE SPARE BREAKER

COMPARTMENT TO SERVE NEW

SECTIONALIZING SWITCH, WITH NEW 400A

BREAKER TO SERVE NEW 15KV FEEDER TO

SECTIONALIZING SWITCH.

23 EXISTING ABOVE GROUND DIESEL FUEL

TANKS TO SERVE NEW DIESEL GENERATOR.

24 SECURITY GATE; PROVIDE 3-8 AWG, 1-8 AWG

EG IN 3/4" CONDUIT

25 LOCATE GENERATOR ANNUNCIATOR PANEL

INSIDE GUARD SHACK. COORDINATE

LOCATION WITH AVAILABLE SPACE ON WALL

AND WITH VA.

26 POWER FOR GENERATOR MAIN TANKS PUMP

FTP-1. PROVIDE FUSIBLE NEMA 3R RATED

DISCONNECT MOUNTED ON SELF

SUPPORTING ANGLE IRON FRAME NEAR

GENERATOR.

27 RELOCATED POLE LIGHT, RE-CONNECT TO

EXISTING ELECTRICAL CIRCUIT AND

CONTROLS. COORDINATE WITH CIVIL

DRAWINGS. DEMO EXISTING POLE BASE.

PROVIDE NEW POLE BASE AS REQUIRED AT

RELOCATED LOCATION. SEE DETAIL 12/E-501.

PROPOSED

PARKING GARAGE

EXISTING VAMC BUILDING

EXISTING PARKING GARAGE

EXISTING

MCR

9A 123A

EXISTING

NETWORK ROOM

BA112E

EXISTING

CCTV

1A113

SEE ES101

SEE ES101

EXISTING

IT/SECURITY

1G130

EXISTING

FIRE ALARM ROOM

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/1

/2

:4

:0

P M

C U s e rs

\a m a s o n

\D o c u m e n ts

\E

-2

-O

K C

P a rk in g G a ra g e a m a s o n a c g -p a .c o m

.r v t

ES102

OVERALL ELECTRICAL CAMPUS PLAN

3 16KLC

PARKING GARAGE 2

921 NE 13TH STREET

OKLAHOMA CITY, OK 73104

JULY 8, 2022

100% CONSTRUCTION DOCUMENTS

635-41419-292

N/A

JKM

1 PROVIDE TWO 4" CONDUITS WITH FIBER FOR

DATA AND PACS. SEE RISER DETAIL 3/E-503

FOR MORE INFORMATION.

2 PROVIDE TWO 2" CONDUITS.FOR FIRE ALARM

FIBER LOOP. SEE DETAIL 1/E-503 FOR MORE

INFORMATION.

3 PROVIDE TELECOM HANDHOLE. SEE DETAIL

11/E-502.

4 LOCATION OF EXISTING FACP.

5 BORE CONDUIT UNDER DRIVEWAY AND

SIDEWALK. COORDINATE WITH COR.

6 RUN FIRE ALARM CONDUITS AND FIBER

CABLING IN CRAWLSPACE. VERIFY EXACT

ROUTING.

7 RUN CONDUIT AND WIRE EITHER TO THE

BASEMENT CEILING AND THEN AS SHOWN

ON DRAWINGS, OR RUN CONDUIT EXPOSED

ON WALL TO ABOVE CEILING AND THEN AS

SHOWN ON DRAWINGS.

Scale: No Scale

OVERALL ELECTRICAL CAMPUS PLAN

F

S

2W 177 Cd

F

S 2W

177 Cd

F

S 2W

177 Cd

F

S 2W

177 Cd

F

S 2W

177 Cd

F

S 2W

177 Cd

C C

DD

EE

GG

E-401

E-402

IT

ELEC

SECURITY

E3

FUTURE

ELEV

E2

ELEV

E1

ELEV

ELEV EQUIP 101

MECHS1

STAIR

S2

STAIR

E-402

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

AA

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

AA

A

A

A

A

A

A

A

A

A

A

A

E2

E1

E2

E2

E2

E2 E2

E2

E2

MS 270MS 270

MS 270

A

A

E-402

E-401

PANEL 'L1'

PANEL 'LS1'

PANEL 'E1'

PANEL 'H1'

MS 360

MS 360 MS 360

MS 360

MS 180

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM EM

EM

EM

EM

EM

EM

EM

'H1'- 9

A

A

A

A

AAA

F

F

F

A

'H1'- 13

'H1'- 5

'LS1'- 5

F

F

'H1'- 11

MS 360

MS 360

A

A

A

A

A

A

A

A

PANEL 'E1L'

F

'H1'- 3

MS 180

EM

EM

EM

AA

BB

FF

5.2

5.2

EM

'H1'- 7

2.2

2.2

B.6B.6

3.1

3.1

3.2

3.2

3.3

3.3

1.6

1.6

'LS1'- 5

'LS1'- 5

'H1'- 8

'LS1'- 5

'LS1'- 5

'H1'- 8

PANEL

'MDP'

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

/1

/2

:4

:4

P M

C U s e rs

\a m a s o n

\D o c u m e n ts

\E

-2

-O

K C

P a rk in g G a ra g e a m a s o n a c g -p a .c o m

.r v t

E-101

LEVEL 1 ELECTRICAL PLAN

4 16KLC

PARKING GARAGE 2

921 NE 13TH STREET

OKLAHOMA CITY, OK 73104

JULY 8, 2022

100% CONSTRUCTION DOCUMENTS

635-41419-292

N/A

JKM

Scale: No Scale

LEVEL 1 ELECTRICAL PLAN

N O

R T

H0 4 8 16

1 CIRCUIT ONLY THE NOTED TYPE A LIGHT

FIXTURES AS NOTED CONTROLLED VIA

ASTRONOMICAL TIME CLOCK AND

PHOTOCELL TO TURN ON AT DAWN AND OFF

AT DUSK. CONTRACTOR TO PROVIDE TIME

CLOCK AS REQUIRED. SEE DETAIL 9/E-501.

2 NEW PAD MOUNTED SERVICE

TRANSFORMER.

N

SCOPE OF WORK

KEY PLAN

SCALE: NO SCALE

AREA OF WORK

A. PROVIDE SSTV CAMERAS, CONDUITS, CABLE,

FIBER TRANSCEIVER, AND POWER SUPPLIES FOR

A COMPLETE SSTV SSYTEM.

B. PROVIDE FIRE ALARM DEVICES, EQUIPMENT,

CONDUIT AND WIRE FOR A COMPLETE FIRE

ALARM SYSTEM.

C. PROVIDE FIBER OPTIC CABLES AND COPPER

CABLES IN CONDUIT AS SHOWN.

D. SYSTEM SHALL BE TESTED AND CERTIFIED

AFTER INSTALLATION.

E. ALL PARKING GARAGE LIGHTING FIXTURES, TYPE

A, WITH PROGRAMMABLE MULTI-LEVEL DRIVER,

SHALL HAVE INTEGRAL PASSIVE INFRARED

OCCUPANCY SENSOR AND AMBIENT LIGHT

SENSOR ENABLED. WHEN AMBIENT LIGHT LEVEL

EXCEEDS 12 FOOTCANDLES, LIGHTS SHALL

REMAIN OFF REGARDLESS OF OCCUPANCY.

WHEN LIGHT LEVELS FALL BELOW 7

FOOTCANDLES, LIGHT SHALL REMAIN IN LOW

MODE DURING NO OCCUPANCY AND SWITCH TO

HIGH MODE AFTER OCCUPANCY IS DETECTED.

CONFIRM PROGRAMMING SETTINGS WITH COR

PRIOR TO COMPLETION.

F. ALL EMERGENCY LIGHTING (EM) SHALL HAVE

BOTH NORMAL AND EMERGENCY POWER.

DURING EMERGENCY CONDITION THE

GENERATOR TRANSFER DEVICE SHALL DETECT

NORMAL POWER VOLTAGE LOSS, TRANSFER TO

EMERGENCY POWER AND RETURN TO FULL-

OUTPUT UPON LOSS OF CONTROL SIGNAL. SEE

DETAIL 8/E-501. NORMAL POWER CIRCUIT AS

SHOWN ON PLAN. LIFE SAFETY EMERGENCY

POWER CIRCUIT AS SHOWN ON PLAN.

G. ALL EXTERIOR LIGHT FIXTURES SHALL BE

CONTROLLED BY INTEGRAL PHOTOCELLS.

H. ALL 120 VOLT 20 AMP 1-POLE BRANCH CIRCUIT

CONDUCTORS SHALL BE AS FOLLOWS, UNLESS

NOTED OTHERWISE:

a. RUNS LESS THAN 150' SHALL BE MINIMUM

2-12 AWG, 1-12 AWG EG IN 3/4" C.

b. RUNS BETWEEN 150'-250' SHALL BE

MINIMUM 2-10 AWG, 1-10 AWG EG IN 3/4"

C.

c. RUNS GREATER THAN 250' SHALL BE

MINIMUM 2-8 AWG, 1-8 AWG EG IN 3/4" C.

B J

C C

DD

EE

GG

E-401

E-402

P2 P2

P2

P2

P2 P2

P2

P2

F

MS 270

MS 270

MS 270

MS 270

'H1'- 4

STAIR

S1

ELEV

E1

ELEV

E2

FUTURE

ELEV

E3

ELEV

LOBBY

'E1L'- 5

AA

BB

FF

5.2

5.2

EM

EM

EM

EM

'LS1' - 1

'LS1' - 1

'LS1' - 1

'LS1' - 1

EM

'LS1'- 1

2.2

2.2

B.6B.6

3.1

3.1

3.2

3.2

3.3

3.3

1.6

1.6

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

/6

/2

:1

:2

A

M C

U s e rs

\a m a s o n

\D o c u m e n ts

\E

-2

-O

K C

P a rk in g G a ra g e a m a s o n a c g -p a .c o m

.r v t

E-102

LEVEL 2 ELECTRICAL PLAN

5 16KLC

PARKING GARAGE 2

921 NE 13TH STREET

OKLAHOMA CITY, OK 73104

JULY 8, 2022

100% CONSTRUCTION DOCUMENTS

635-41419-292

N/A

JKM

N O

R T

H0 4 8 16

Scale: No Scale

LEVEL 2 ELECTRICAL PLAN

N

SCOPE OF WORK

KEY PLAN

SCALE: NO SCALE

AREA OF WORK

A. PROVIDE SSTV CAMERAS, CONDUITS, CABLE,

FIBER TRANSCEIVER, AND POWER SUPPLIES FOR

A COMPLETE SSTV SSYTEM.

B. PROVIDE FIRE ALARM DEVICES, EQUIPMENT,

CONDUIT AND WIRE FOR A COMPLETE FIRE

ALARM SYSTEM.

C. PROVIDE FIBER OPTIC CABLES AND COPPER

CABLES IN CONDUIT AS SHOWN.

D. SYSTEM SHALL BE TESTED AND CERTIFIED

AFTER INSTALLATION.

E. SEE STRUCTURAL PLANS FOR POLE BASE

DETAILS. PROVIDE POLE BASES WITH

SUFFICIENT CONDUIT FOR WIRING REQUIRED

PLUS ONE ADDITIONAL 1" CONDUIT STUBBED

OUT AND CAPPED AS SPARE. COORDINATE WITH

PRECAST PROVIDER FOR CONDUIT QUANTITY

AND SIZES AND POLE ANCHORS. WIRING WITHIN

POLES MUST COMPLY WITH NEC 800.133(A)(2)

AND 700.10(B). ROUTE CONDUCTORS WITHIN

POLES IN EMT OR LFNC AS REQUIRED.

F. ALL EMERGENCY LIGHTING (EM) SHALL HAVE

BOTH NORMAL AND EMERGENCY POWER.

DURING EMERGENCY CONDITION THE

GENERATOR TRANSFER DEVICE SHALL DETECT

NORMAL POWER VOLTAGE LOSS, TRANSFER TO

EMERGENCY POWER AND RETURN TO FULL-

OUTPUT UPON LOSS OF CONTROL SIGNAL. SEE

DETAIL 8/E-501. NORMAL POWER CIRCUIT AS

SHOWN ON PLAN. LIFE SAFETY EMERGENCY

POWER CIRCUIT AS SHOWN ON PLAN.

G. ALL EXTERIOR LIGHT FIXTURES SHALL BE

CONTROLLED BY INTEGRAL PHOTOCELLS.

H. ALL 120 VOLT 20 AMP 1-POLE BRANCH CIRCUIT

CONDUCTORS SHALL BE AS FOLLOWS, UNLESS

NOTED OTHERWISE:

a. RUNS LESS THAN 150' SHALL BE MINIMUM

2-12 AWG, 1-12 AWG EG IN 3/4" C.

b. RUNS BETWEEN 150'-250' SHALL BE

MINIMUM 2-10 AWG, 1-10 AWG EG IN 3/4"

C.

c. RUNS GREATER THAN 250' SHALL BE

MINIMUM 2-8 AWG, 1-8 AWG EG IN 3/4" C.

I. PROVIDE MASTER-LABEL LISTED LIGHTING

PROTECTION SYSTEM. REFERENCE DETAIL

SHEETS FOR GROUNDING AND LIGHTNING

PROTECTION AIR DETAILS.

1 PROVIDE PEDESTAL TYPE EMERGENCY

PHONE WITH BLUE LIGHT WITH 120V

EMERGENCY POWER. SEE DETAIL 7/E-502.

2 CAMERAS TO BE MOUNTED ON THE LIGHT

POLE, TWO FEET BELOW FIXTURE. RUN

CABLE IN CONDUIT INSIDE LIGHT POLE.

3 PROVIDE GROUND CONDUCTOR IN CONDUIT

CAST IN CONCRETE SUPPORTING GARAGE.

COORDINATE WITH STRUCTURAL.

C

C

C

C

C C

C

C

C

C C

C C

C C

C C

C C

C

C

C

C

C

C

C

I C

IC

SP

SP

C C

C

C

C

C

C

CC

C C

C O

N C

R

A M

P C

O N

C R

A M

P

DN

UP

STAIR #3

AREAWAY

AREAWAYAREAWAY

AREAWAY

AREAWAY

STAIR #4

AREAWAY AREAWAY

ELEV. P-3

ELEV. P-4

ELEV. P-5

ELEV. P-6

ELEV. P-2

ELEV. P-1

CHASE

STAIR #8

STAIR #7

ELEV. P-12

ELEV. P-11

P-10

ELEVATOR

P-9

ELEVATORELEVATOR

P-8

ELEVATOR

P-7

CHASE

STAIR #1

STAIR #2

P

IP

E C

H A

S E

STAIR #3

STAIR #4

STAIR 10

STAIR #6

STAIR

#15

U P

F

IL

E S

S H

E L

V

IN

G

BOOK

CASE

S H

E L

V

IN

G S

H E

L V

IN

G

S H

E L

V

IN

G S

H E

L V

IN

G

SHELVING SHELVING SHELVING

B A

T T

E R

Y B

A C

K U

P

B A

T T

E R

Y B

A C

K U

P

S

S

S

S

S

S

S

S4S1 S2 S3 S5

S

S

B9B

B3

B2

B5

B4

B1

B10

B13

B11

B12

S

B

B

B

B

MAIL

DROP

C O

N C

R E

T E

B E

A M

H E

IG

H

T

F .F

T

O A

P P

R O

X

A .F

.F

C O

N C

R E

T E

B E

A M

H E

IG

H

T

F .F

T

O A

P P

R O

X

A .F

.F

C O

N C

R E

T E

B E

A M

H E

IG

H

T

F .F

T

O A

P P

R O

X

A .F

.F

CONCRETE BEAM HEIGHT: F.F. TO APPROX. 58" A.F.F.

563_ "H X 17 1_

"D WALL563_

"H X 18"D WALL

3_4 "H X

"D

W A

L L

621_

"H X 13"D WALL12"D12"D

CBF 2

CBF 14

C B

F

C B

F

CBF 8

CBF 10

C B

F

C B

A

C B

B

CBB 2

C B

B

C B

B

C B

B

CBB 5 CBB 4

C B

C

-1 A

CBA 3

C B

F

CBA 1 CBA 2

C B

A

C B

F

CBF 3 CBF5

C B

F

CBF 7

CBF 9

CBF 12

C B

F

C B

B

CBF 12

C B

B

ACCESS

PNL

3'x3'

2'x2'

19"x19"

19"x19"

30"x60"

2'x2'

3'x3'

15"x15" 20"x18"

3'x3'

PNL

ACCESS

DOWN

XEROX DC 6060

XEROX HL COLOR

SAFE

SHREDDER

HL SLOSLO

SLO

FIERY

MAIN PROCESSOR

M A

IN

P

R O

C E

S S

O R

FREE FLOW

FINISHING TABLE FINISHING TABLE

PERFORATOR

DRILL

CUTTER

WORK

STA.

USPS TABLE POSTAGE

P O

S T

A G

E

IN

S E

R T

E R

DM-800

D I-

D M

-8

MAIL SHELVES/

BINS

SORTING TABLE

SORTING TABLE

REFRIG

SHREDDER

C A

B

XEROX

SHRED

IT

OIL - WATER SEPARATOR TANK

18" DIA. MANHOLE & C.I. COVER-FLUSH W/SLAB

1,000 GAL. STORAGE

TANK PUMPOUT CONNECTION

DECON SHOWER

HOLDING TANK

CONTAMINATED WATER

DIVERSION VALVE PIT

DWN

RAMPRAMP

DWN

RAMP

DWN

RAMP

DWN

CENTRIFUGAL

CHILLER

ABSORPTION

CHILLER

#6

#5 #4

#7

#4

#6

OLD DENTAL AIR

(Dead Line)

.0

C O

P

IE

R

WORKSTATION

2 LIGHT X-RAY VIEW BOX

WORKSTATION

42"∅

L O

C K

E R

S

FILES

F

IL

E S

HI-FI

LAMINATOR TABLE

W/OVERHEAD SHELVES

P E

D

60x24

P E

D

F/S/L 42P

E D

F/S/L

84x24

F/S/LF/S/L

P E

D

48x24

F/S/L x3

L C

A R

T

X

C -C

A R

T

LCART

20X24

C

LOCKER

20X24

SCALE

LCART

20X24

O M

I-C E

L L

X

MED

REFRIG

27X30

C O

R K

B D

SHRED S/L

48x24

P E

D

C

LOCKER

20X24

C L

O C

K E

R

X

60x30

LCART

20X24

C

LOCKER

20X24

0x3

0x3

PED

x

F /S

/L

F

/S /L

(4

L F

(1

F D

(4

L F

(1

F D

PED

x

F /S

/L

F

/S /L

F /S

/L 3 x

PED

(4) LF

30PRINTER

F /S

/L 3

SHELVES

S H

E L

V E

S

SHELVES

SHELVES

SHELVES

3 3 3

1 1

1 1

W O

R K

S T

A T

IO

N

SHELF SIZES, EXISTING

36"x18"x86.75"

38"x18"x76.25"

36"x18"x78"

61.5"x25"x72.5"

48"x18"x86.75"

SHELVING SHELVINGSHELVINGSHELVING

S H

E L V

IN

G

SHELVING

MTL SHELF

M T

L S

H E

L F

M T

L S

H E

L F

PALLET

PALLET

3636 36

PALLET PALLET

MTL SHELF MTL SHELF

PALLET PALLET

MOTION

DETECTOR

SWITCH

DETECTOR

MOTION

6" PIPE

BOLLARD

S

S

I

IB

I

I

I

I

I

I

I

I

I

I

I

I

C

C

C

C

C

C

C

C

C

C

C

C C

C

C

C

C

C

C

C

C

C

C

C

C C

C

C

C

C

CC

EYE WASH

HC

AWAITING ASBUILTS

UNEXCAVATED

PLANTER

PARKING

PLANTER

PLANTER

PLANTER

MAIL ROOM

MAIL ROOM

ELECTRICAL

ENG

OFFICE ENG

SHOP

IM

OFFICE

OFFICE

IM

OFFICE

SOILED LINEN

TELEPONE OPERATORS

BREAK ROOM

TELEPHONE

EQUIPMENT

STORAGE

RESTROOM

TELEPHONE EQUIPMENT

PHARMACY STORAGE

ACQUISITIONS

OFFICE

PSYCH.

OBSERVATION

PSYCH. OBSV.

SPS

STORAGE

SOILED

HOLDING

TELE/DATA

DUMB

WAITER

FAMILY ROOM

WHEEL CHAIR/

STRETCHER

AMMO

STORAGE

STORAGE

ENGINEERING

SHOP

CANTEEN

STORAGE

BIO MED

OFFICE

IV

STORAGE

MEDICAL GAS

STORAGE

ER BREAKROOM

ACQUISITIONS

GENERAL

STORAGE

EMS

TRASHCART

WASH ROOM

EMS

CLEAN LINEN

EMS

STORAGE

ENG

PAINT SHOP

ENG

ELECTRICAL

SUB-STATION - 2

EMS

WAREHOUSE

MEN'S

RESTROOM

IM

STORAGE

WAREHOUSE

LOADING DOCK

NUTRITION &

FOOD SERVICE

WAREHOUSE

SPS

MEDICAL

STORAGE

AQUISITIONS

SUPPLY

RECEIVING

MECHANICAL

EQUIPMENT RM

EMS

EQUIPMENT

STORAGE

IM

MULTIPURPOSE

EMS

OFFICE

EXAM ROOM

(INFECT. ISOL.)

EMERGENCY

GENERATOR

ELEVATOR

LOBBY

ELEVATOR

ROOM

EXAM ROOM

EXAM ROOM

EXAM ROOM

EXAM ROOM

FAST TRACK

S T

O R

A G

E

EXAM ROOM

TREATMENT ROOM 1

TRAUMA ROOM

TREATMENT ROOM 2

TREATMENT ROOM 3

TREATMENT ROOM 4

TREATMENT ROOM 5

TREATMENT

ROOM

TREATMENT

ROOM

MEDS

BREAKROOM/

LOCKERS

H.A.C.

NURSE

STATION

SLEEP

ROOM MECH.

TOILET

RESTROOM/

SHOWER

STORAGE

TOILET

TOILET MALE

TOILET FEMALE

ELEC.

BIO MED

OFFICE

BIO MED

SHOP

X-RAY

MAINT

ELEC. CLO.

MECANICAL ROOM

MECANICAL ROOM

AREAWAY

BIO MED

RECEPTION

BIO MED

SHOP

OFFICE

NURSING OFFICE

EMS

SOILED

LINEN

LOGISTIC

STORAGE

PATHOLOGY

COOLER

HAZARDOUS

WASTE

STORAGE

ACQUISITIONS

OFFICEACQUISITIONS

GENERAL

STORAGE

CANTEEN

STORAGE

TELE/DATA

ENGINEERING OFFICE

ENGINEERING STORAGE

ENGINEERING STORAGE

ENGINEERING STORAGE

ENGINEERING STORAGE

UNEXCAVATED

ENG

STORAGE

EMS

WALK-IN

REFRIG. T

O

IL

E T

TELE/

DATA

ENG

MECHANICAL

CANTEEN STORAGE

FOOD SVC

STORAGE

FOOD SVC

DUMBWAITER

FOOD SVC

WALK-IN

FREEZER

FOOD SVC

WALK-IN

REFRIGERATOR

FOOD SVC

WALK-IN FREEZER

A F

G E

S T

O R

A G

E

EMS

RED BAG

FOOD SVC

WALK-IN

REFRIGERATOR

FOOD SVC

STORAGE

FOOD SVC

KITCHEN MISC.

FOOD SVC

STORAGE

FOOD SVC

WALK-IN

REFRIGERATOR

FOOD SVC

WAREHOUSE

IM

STORAGE

ENG

EQUIPMENT

STORAGE

ENG

EQUIPMENT

STORAGE

EMS

LINEN CHUTE

LOCKSMITH

E L

E C

T R

IC

C

L O

S E

T

EMS

STORAGE

ELEC.

CLOSET

EMS

WAREHOUSE

EMS

STORAGE

EMS

STORAGE

EMS

STORAGE

CLOSET

EMS

STORAGE

EMS

LAUNDRY

EMS

OFFICE

EMS

SOILED LINEN

IM

FOYER

EMS H.A.C.

EOC

STORAGE

ENG

PATHOLOGY

STORAGEOFFICE

H.A.C.

EMS

STORAGE

EMS

CLEAN

LINEN

EXAM ROOM 7

EXAM ROOM 8

EXAM ROOM

(INFECT. ISOL.)

DECONTAMINATION

TOILET

PA

TIE

N T

R

EC

EIV

IN

G

HOLDING

POLICE

POLICE

LOCKERS

INTERVIEW

(TRIAGE)

H.A.C.

X-RAY ROOM

CLEAN LINEN

MEDS

NURSE STATION

FIRE PUMPSUBSTATION #3

EXAM ROOM 6 EXAM ROOM 5

MECHANICAL

ELECRICAL

CLOSET

VENDING

ENTRANCE

T E

L E

D

A T

A

MECHANICAL ROOM

TELE/DATA

WAITING

ELEC

FEC

FEC

F E

C

MEDICAL GAS

STORAGE

AMBULANCE ENTRANCE

OFFICE

ELECTRICAL

S T

O R

A G

E S

T O

R A

G E

EXIT

EXIT

STORAGE

MAIL ROOM

D R

E S

S

IN

G R

O O

M

SMOKE SHACK SMOKE SHELTER

(OUTSIDE

SMOKING)

(INSIDE SMOKING)

EXAM

ROOM

EXAM

ROOM

MED

EOC

STORAGE

BF144e

BF111

BF146

BF147

BF148

BF144a

BF144

BF142

BF141

B F q

BF145a

BF145b

BF145c

BF145d

BF145e

BF145f

BF145g

BF145g1

BF145h

BF145iBF145j

BF145k

BF145p

BF145m

BF145o

BF145l

BE102c

BE100a

BE101

BE100

BE100b

BE100c

BE100d

BE102a

BE102b

BE102d

BE102

BF118

BF118a

BA119f

BA117

BA116

BA116a

BA127

BA118BA119

BA119b BA119c

BA121BA122

BF106 BA119g

BA125

BA126

BA128 BA130

BA130b1

BA130b

BA123

BA124

BA130a

BA114

BA115a

BA115

BA115b

BA113

BA112e

BA112

BA111

BA112a

BA112b

BA112c

BA112d

BA112e1

BA110

BA108BA109 BA106

BA107a

BA107

BA105a BA105b

BA105 BA105d

BA105c

BB133

BB134

BA104BA103

BA102

B A

B A

BA131

BB135

BB100

BB102

BB103

BB104

BB106

BB105

BB105a

BB107

B B

BB108 BB108d

BB108a BB108c

BB109

BB110

BB133

BB110a1

BB110a

BB132

BB132a

BB131

B B

B B

BB130

BB126

BB127

BB111BB112

BB115

BB114

BB116

BB117

BB118

BB119

BB120

BB121

BB122

BB121a

BC100

BC100a

BC100b

BF108 BF107

BF114

BF115

BF130

BF131

BF132

BF133

BF129

BF129a

BF128

BF125b

BF126

BF125

BF127

BF127a

BF153

BF154

BF124

BF123

BF122

BF121

BF119

BF120

BF135

BF134

BF136 BF137 BF138

BF113BF112

BF139 BF140

BF155

BF150

BF151

BF117

BF116

BF149

BF128

BF145n

BF145

BF128

BB107a

BE102e

BF153

B F a

B F b

B B a

BF144b BF144c

BF144d

UP

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/1

/2

:4

:4

P M

C U s e rs

\a m a s o n

\D o c u m e n ts

\E

-2

-O

K C

P a rk in g G a ra g e a m a s o n a c g -p a .c o m

.r v t

E-103

BASEMENT FLOOR FIBER ROUTING

PLAN

6 16CNJ

PARKING GARAGE 2

921 NE 13TH STREET

OKLAHOMA CITY, OK 73104

JULY 8, 2022

100% CONSTRUCTION DOCUMENTS

635-41419-292

N/A

JKM

Scale: No Scale

BASEMENT FLOOR FIBER ROUTING PLAN

A. SEE DETAIL 3 ON DRAWING E-503 FOR FIBER

OPTIC REQUIREMENTS.

B. SUPPORT FIBER OPTIC CABLES IN THE EXISTING

CABLE TRAY. IF CABLE TRAY IS NOT PRESENT

SUPPORT CABLES ON J-HOOKS EVERY 4-5 FEET

PER BICSI.

1 EXISTING TELECOM ROOM/OIT TO REMAIN.

SEE RISER DETAIL 3 ON DWG E-503 FOR

MORE INFORMATION.

6E

E

B B

F

BBF

F

SPEC 8101MSPEC 8101MSPEC 8102M SPEC 8101MSPEC 8101MSPEC 8102M

B B

F

36F x6 x6

BBF

x6

B B

FF

F

FF

BBF

F

BBF

F

B B

F

36F x6

36F 36S

F

B B

F

BBFBBF

BBF

CHASE

OPEN TO LOWER

ROOF OF

LOWER LEVEL

LEVEL OF GD106b

UPPER LEVEL

SEATING

MEDICAL MEDIA &

AUDITORIUM

ELEVATOR

P-1

ELEVATOR

P-2

ELEVATOR

P-3

ELEVATOR

P-4

ELEVATOR

P-5

ELEVATOR

P-6

STAIR 5STAIR 2

S T

A

IR

S T

A

IR

STAIR 12

STAIR 1

STAIR 11

C G

A

VENDOR

RACK RACK

VENDOR

RACK

VENDOR

D O

W N

D O

W N

D O

W N

D O

W N

U P

U P

U P

U P

LAUNDRY ROOF

S

PED

C1

P E

D

P E

D

86x2457x24 x

60x24

P E

D

60x24

P E

D

C

PED

C x

C1 C1

C1

C1

PED

C1

C

P E

D4 x

48x24

RICOH

COPIER

x

PED

C1 x

D E

S K x

D E

S K

PED

84x24

42 42

FILE

PR F

FILE

C16 x

PED

x

PED

C1 x

PED

C1 6 x

PED

C1 x

PED

C1 x

PED

C1

24X30

X

30/60

30F

24X60

30F

F

X

F

30X42

F

X

24X60

F

X

24x60

F

F

30S 30F

30S 30F

30/60

30F

24X60

30F

30/60

30F

24X60

30F

/6

F

X

F x

B B

F

WSSP

x6

30F

60x24

30F 3 S x

F

48F

48x24BBF

F

BBF

/6

F

X

F

F

30F (2)

24X60

30S30S

24X60

30S30S

24X60

30S 30SRICOH

COPIER

EQPT

S

F

139 SF

S

F S

F

358 SF

S

F

S

F

563 SF

306 SF

490 SF

S

F

S

F

467 SF

S

F

S

F

521 SF52

SF

S

F

S

F

CGB 2

C G

B

C G

B

C G

D

1CGD 2

CGH 10-1

CGD 4

C G

H

CGH 3

C G

H

-1

C G H 8-1

C G

H

C G

H

CGD 3

C G H

C G

H 6 C G

H

C G

B

ROOF

FRESH

C H

OIC

ES

B

ISTRO

HO

T

WE

LLHO

T

WE

LLHO

T

WE

LL

HO

T /

CO

LD

HO

T /

CO

LD

HO

T

WE

LL

P A S T R Y C O F F E E

S T A N D

C O L D

B E V E R A G E S

Q U

IC

K

S T O P

D E S S E R T

IN

N

CHICKEN

EXPRESS

HOOD EQUIPMENT

FIRE SUPPRESSION HOOD

H

OT

W

EL

L

H

OT

W

EL

L

H

OT

W

EL

L

H

OT

W

EL

L

H

OT

W

EL

L

H

OT

W

EL

L

H

OT

W

EL

L

H

OT

W

EL

L

H

OT

W

EL

L

H

OT

W

EL

L

H

OT

W

EL

L

H

OT

W

EL

L

H

OT

W

EL

L

H

OT

W

EL

L

H

OT

W

EL

L

OLD DENTAL AIR

(Dead Line)

KEYBOARD

PC

BULLETIN BOARD

KEYBOARD

FUTURE

PC

M O

N

IT

O R

T V

M O

N

IT

O R

BULLETIN BOARD

EXPANSION TANK

OFFICE

PRIMARY

CARE

EYE CLINIC

SUPERVISOR

ELEC

T E

L E

D

A T

A

ELECTRICAL

BENEFICIAL TRAVEL

BLDG.

CANTEEN RETAIL

STORE

OFFICE

OXYGEN STORAGE

VTS ADMIN

WHEELCHAIR

STORAGE

ALLERGY

CLINIC STORAGE

OFFICE

OFFICE

PRIMARY

CARE

OFFICE

PRIMARY

CARE

MOBILE FILE

ROOM

NEGATIVE CHEMO

CLEAN ROOM

POSITIVE IV

CLEAN ROOM

ANTE-ROOM

POSITIVE

ANTE-ROOM

PHARMACY

STORAGE

EMS

OFFICE

LOW VISION

EXAM ROOM

TELE/DATA

C A

N T

E E

N S

T O

R A

G E

C A

N T

E E

N S

T O

R A

G E

C A

N T

E E

N S

T O

R A

G E

CANTEEN

CANTEEN KITCHEN

H.A.C.

FREEZER

FOOD STORAGE

FOOD STORAGE

DELI

OFFICE

CANTEEN SERVICE

E L

E C

H.A.C.

STORAGE

TRAY WASH

T E

L E

/D A

T A

C L O

S E

T

ELEC

ELEC

CANTEEN

DINING ROOM

MECHANICAL ROOM

TOILET

FEMALE

TOILET

MALE TRAVEL

WAITING ROOM

PATIENT TRANSPORT

MECHANICAL ROOM

E L

E C

T R

IC

C

L O

S E

T

TOILET FEMALETOILET MALE

LOWER

STORAGE

COVID SHOTS

COVID

LAB

MALE

LOCKER ROOM

FEMALE

LOCKER ROOM

STORAGE

COVID SHOTS

OBSERVATION

ALLERGY CLINIC

H.A.C.

FEC

E L E

C

T E

L E

D

A T

A

FEC

FEC

F E

C

BENE TRAVEL/

VETERAN TRANSPORT

MECHANICAL ROOM

MEDICAL MEDIA STORAGE

STORAGE STORAGE

STORAGESTORAGE

M E

C H

A N

IC

A

L R

O O

M

OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE

A B

A N

D O

N E

D D

U M

B W

A

IT

E R

S H

A F

T

OFFICE

STORAGE OFFICE

OFFICE

OFFICE

BREAK ROOM

ELEC

CLASSROOM

K

IT

C H

E N

OFFICE

OFFICE

OFFICE

OPTICAL

SHOP

SHOP/

STORAGE

SOILED

UTILITY

OFFICE

NURSING

SERVICE

EXAM ROOM

PRE-TESTING

#1

EXAM ROOM

PRE-TESTING

#2

EXAM ROOM

PRE-TESTING

#3

EXAM ROOM

PRE-TESTING

#4

EXAM ROOM

PRE-TESTING

#5

EXAM ROOM

PRE-TESTING

#6

EXAM ROOM

PRE-TESTING

#7

OFFICE

STORAGE

WAITING

BREAK AREA

OFFICE

OFFICE

WAITING

OFFICE

OFFICE

OFFICE

OFFICE

ALLERGY

CLINIC

WAITING

VOLUNTEER

STORAGE

WAITING

ALLERGY

CLINIC STORAGE

MOBILITY MANAGEMENT/

BENEFICIAL TRAVEL

SUPERVISOR

OFFICE

LEAD OFFICE

LOW VISION

TRAINING ROOM

PCPC PC

NIGHT

DROP

D

IS

P L

A Y

C A

S E

A L

A R

M S

W

IT

C H

GA154

GA153

GA152

GA151

GA108

GA115GA114GA113GA112

GA109

GA107

GA106

GA105

G A

G A

G A

GA103

G B

G B

G B

GB104b

GB104d

GB104c

GB104

GB104f11 GB106a

GB106GB106b

GB104f

G B

GB119

GB106c

G B l

GB104k

GB118a

GB117

GB108

G B

GB110

GB115

GB114

GB111

GB113GB112

GD101GD101a

G D

GD108GD107

GH100GH101

GD103

GD104

GD102

GD105

GD106b GD106b1

GD106a

GD106

G D e

GD106d

GD106c

GH104

GH105

GH119

GH117

GH118

GH106 GH107 GH108 GH110 GH111 GH114 GH115 GHH116

GH113GH112

GH109

G H a

GD106g

GD106f

GD102a GD102b

GD102

GB104j

GB104g

GA142b1 GA142a1

GA142b GA142a

GA142

GA143d

GA104

GB103

GB104e

GB104h

GB104i

GB104k1

GB109

GB116

GB118

GH103

GH102

GA143

GB121d

GB121a

GA109a

GA110 GA111

GA111a

GA116

GB121b

GB121c

GB121

GB121e

GB120b

GB120a

GB120

GB120f

GB120e

GB120d

GB120c

GD107a

GB110a

GA104a

UP/DOWN

SEE

BASEMENT

PLAN ON E-103

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/1

/2

:4

:4

P M

C U s e rs

\a m a s o n

\D o c u m e n ts

\E

-2

-O

K C

P a rk in g G a ra g e a m a s o n a c g -p a .c o m

.r v t

E-104

GROUND FLOOR FIBER ROUTING PLAN

7 16CNJ

PARKING GARAGE 2

921 NE 13TH STREET

OKLAHOMA CITY, OK 73104

JULY 8, 2022

100% CONSTRUCTION DOCUMENTS

635-41419-292

N/A

JKM

Scale: No Scale

GROUND FLOOR FIBER ROUTING PLAN

A. SEE DETAIL 3 ON DRAWING E-503 FOR FIBER

OPTIC REQUIREMENTS.

B. SUPPORT FIBER OPTIC CABLES IN THE EXISTING

CABLE TRAY. IF CABLE TRAY IS NOT PRESENT

SUPPORT CABLES ON J-HOOKS EVERY 4-5 FEET

PER BICSI.

COPIER

P R

T

FAX

PRT

C O

P

IE

R

C O

P

IE

R

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

CC

C C

C

C

C

ELEVATOR

P-6

ELEVATOR

P-5

ELEVATOR

P-4

ELEVATOR

P-3

ELEVATOR

P-2

ELEVATOR

P-1

S T

A

IR

-1

ELEVATOR

P-11

CHASE

CHASE

ELEVATOR

P-8

ELEVATOR

P-7

ELEVATOR

P-10

ELEVATOR

P-9

STAIR 8

CHASE

STAIR 9

MECHANICAL

CHASE

STAIR 11

STAIR 5

STAIR 1

STAIR 12

BUILDING #19

S T

A

IR

S T

A

IR

STAIR 2

STAIR 7

CHASE

CHASE

STAIR 6

D N

U P

UNDER CONSTRUCTION

UNDER CONSTRUCTION

UNDER CONSTRUCTION

APAP

APAP

AP

D48 D47 V25

D44 D43 V23

D42

D41 V22

D40

D39 V21

D46

V24 D45

D50

D49 V26

D51 D52

V27

D54

V28 D53 D55

D56

V29

V5D14

D13 V7

D10

D9

D16

D15 V8

D11

D12

V6

D2 D1 V1

TTT TT

T

T T T T T

T

T T

T T T T T

T

T

T

T

MP

MA

MB

MG

PBK

S

F

1194 SF

S

F

619 SF

158 SF7

S

F

79 SF

S

F

154 SF

S

F S

F

117 SF

637 SF

S

F

866 SF

S

F

815 SF

954 SF

S

F

S

F

S

F

1040 SF

296 SF 890 SF

S

F S

F 586 SF

S

F

190 SF

S

F

S

F

100 SF

561 SF

383 SF

1176 SF

S

F

S

F

80 SF

86 SF

S

F

S

F

S

F

883 SF

S

F

S

F

500 SF

S

F

230 SF

C

B

-1

C G

C A

C1A 2-1 C1A 2

C A

C A

C A

C1A 6

C A

C B

C

B

C1B 3

C1B 5

C1B 6

C B

C1E 1

C1E 2

C E

C1E 4

C E

C1F 1-1

C F

-1

C F

-1

C1F 4-1

C F

-1

C F

-1

C1F 7-1

C1F 8-1

C1F 9-1

C1F 10-1

C1F 13-1

C F

-1

C1F 15-1

C1F 16-1

C F

-1

C F

-1

C1F 19-1

C F

-1

C F

-1

C F

-1

C1G 2

C1G 3

C G

C1G 5

C1G 6

C G

C1G 8

ROOF

ROOF

OLD DENTAL AIR

(Dead Line)

PUMPS

VACUUM

4"

MOTOR

PUMP

4" VENT TO 4TH

FLR ROOF

ORAL EVACUATION

ACCUMULATOR TANK

3" DRAIN

COLLIMATOR COLLIMATOR

UPS

OPEN TO DECK

OPEN TO DECK

NOTE: CEILING HEIGHT @ 108'-0"

NOTE: CEILING HEIGHT @ 108'-0"

EXISTING ELECTRICAL

FLOOR TRENCH

WD

PBS

MB

MA

MS

PBK

MW

PHY

AC

TV

MSA

SP

ME

MS

HATCHED FLOOR IS NOT

LEAD SHIELDED

LEAD SHIELDING IN

THIS AREA IS

2-LAYERS AT 1/32"

S

S

S

S

I

SP

S

UNIT

MOB.

COPIER

PROJECTOR

S C

R E

E N

T V

T V

S C

R E

E N

SCREEN

R E

F

-B

A Y

/3 -T

IE

R

S E

C U

R

IT

Y C

O N

S O

L E

SHREDDER

S H

R E

D D

E R

OVEN

VACUUM FORMER

T H

E R

M O

F O

R M

E R

C A

R V

E R

THERMO

FORMER

T O

O L B

O X

T O

O L B

O X

SAND

BLASTER SHOE

SOLER

SHOE

MACHINE

TOOL BOX

PUNCH PRESS

DRILL

PRESS

ROUTER

SANDER S

A

N D

E

R ROUTER

BAND SAW

DRILL

PRESS

PLASTER

TRAP

AWAITING ASBUILTS

AWAITING ASBUILTS

A W

A

IT

IN

G

A S

B U

IL

T

S

AWAITING ASBUILTS

AWAITING ASBUILTS

A W

A

IT

IN

G

A S

B U

IL

T

S

IMAGING

ROOM

PREP ROOM

IMAGING

ROOM

TOILET FEMALE

TOILET MALE

IMAGING

ROOM

FELLOWS

OFFICE

HEART STATION

WORKROOM

OFFICE

CARDIOLOGY

WET LAB

BREAK

ROOM

SUPPLIES

CONTROL

ROOM

IMAGING

ROOM

PHYSICIAN

READING ROOM

WAITING

AREA

RECEPTION

FILES CHIEF OFFICE

OFFICE

SUPERVISOR

OFFICE

ADMINISTRATIVE

PHYSICIST

OFFICE

COMPUTER

ROOM

IMAGING

ROOM

PATIENT

INJECTION

TOILET

ELEC

H.A.C.TELEPHONE

CLOSET

RESIDENTS

WORK

ROOM

OFFICE

TECH

SUPERVISOR

DOCTOR

OFFICE

MEDS

STAFF WORK

AREA

DOCTOR

OFFICE

NURSING

LOUNGE

OFFICE

EXAM

EXAM

TREATMENT

PLANNING /

DOSIMETRY

EXAM

EXAM

EXAM

ELECTRICAL

SUBSTATION

PATIENT

TOILET

PATIENT

TOILET

WAITING

PATIENT

DISCHARGE

LOBBY

ELECTRICAL/

MECHANICAL

CLOSET

PHYSICS

STORAGE

VESTIBULE

SOILED UTILITY

HOLD / SUB-WAIT

CLEAN UTILITY

CLEAN LINEN

L

IN

A C

C

O N

T R

O L

CT TOILET

P H

Y S

IC

IS

T W

O R

K A

R E

A

L

IN

A C

C

O N

T R

O L

HOT LAB

PDA PDA PDA

CT SIMULATOR CT

CONTROL

PET/CT

LINAC 2

LINAC 1

EXAM

EXAM

EXAM 3 EXAM 2

EXAM

HOMEOXY.

COR/

PURCHASING

OFFICE

WAITING

AREA

RECEPTION

AREA

STORAGE

SOILED

UTILITY

MECHANICAL ROOM

CHIEF

OF

SERVICE

EXAM

EXAM

PARALLEL

BARS

ELEC

H.A.C.

CLEAN

LINEN

PRACTITIONERS'

OFFICE

TOILET

MALE

KITCHENETTE

TOILET

FEMALE

THERMO PLASTIC

MOLDING & WELDING

PLASTER

MODELING

CARVER

MACHINE

ROOM

INVENTORY/

STORAGE

SEWING ROOM

LAB CHIEF

STORAGE

OFFICE

TECHNICIAN

STORAGE

ELEC

COMPUTER

ROOM

E MODULE

CHECK IN

E M

O D

U L

E W

A

IT

IN

G

R O

O M

TOILET MALE

TOILET FEMALE

PFT

MAS/

CHECK OUT

EXAM

EXAM

PROCEDURE

ROOM

TEAM

ROOM

EXAM

HAC

PATIENT RESTROOM

SOILED

LINEN

TEAM

ROOM

OFFICE

STORAGE

OFFICE

OFFICE

T E

L E

/D A

T A

E L

E C

T R

IC

A

LOFFICEOFFICEOFFICEOFFICECONFERENCE ROOMOFFICEOFFICE

H.A.C.

ELECTRIC

CLOSET

STORAGE

OFFICE

SUPERVISOR OFFICE

OFFICE

OFFICE

OFFICE

OFFICEOFFICE

OFFICE

OFFICE

OFFICE

TOILET MALE

MAS OFFICE

CHECK OUT

MAS

CHECK IN

WAITING

ROOM

MECH

EQUIPMENT

RM.

SECURITY

MONITORPROJECTOR ROOM

NEURO

TEAM

ROOM

FOYER

MED TEAM

ROOM

VESTIBULE

SUITE

CARDIAC CATH

LAB

RECOVERY/HOLDING

EQUIPMENT

CONTROL

ROOM

CARDIAC

CATH LAB

#1

CARDIAC

CATH LAB

#2

CONTROL

ROOM

SCRUB

STORAGE

CLEAN

UTILITY

EXAM

ROOM 6

ELEC

CLOSET

MED TEAM

ROOM

TREATMENT ROOM

ISOLATION

TREATMENT

ROOM

ISOLATION

TOILET

ELEC.

CLOSET

SOILED UTILITY

PHARMACIST

TOILET

MED GAS

STORAGE

CLEAN

LINEN

TRIAGE

CHECK-IN

CONSULTATION

WAITING

TOILET

NURSE

STATION

KITCHEN

TREATMENT AREA

C H

A

IR

C H

AIR

#4

C H

A

IR

C H

A

IR

C H

A

IR

C H

A

IR

CHAIR

#4

CHAIR

#3

CHAIR

#2

CHAIR

#1

NEURO CLINIC

INFUSION CLINIC

ELECTRICAL CLOSET

E Q

U

IP

VIEWING ROOM MEN WOMEN

STRESS LAB

EQUIPMENT

SPEECH

PATHOLOGY

TREATMENT

SPEECH PATHOLOGY

OFFICE

EARMOLD

LAB

OFFICE

OFFICE

PACEMAKER

EXAM

ECHO

LAB

SECRETARY

EXAM EXAM

STORAGE

EXAM

ECHO

EXAM

EXAM

ECHO

EXAM

ECHO

READING ROOM

STORAGE

SPEECH

OFFICE

COMPUTER

ROOM

SPEECH

PATHOLOGY

OFFICE

SPEACH

PATHOLOGY

LAB

SPEACH

PATHOLOGY

SECTION

CHIEF

STAFF

LOUNGE

ELECTRIC CLOSET

EXAM

E.K.G.

EXAM

E.K.G.

EXAM

E.K.G.

PFT

TOILET

FEMALE

OFFICEEXAMEXAMEXAM

OFFICEOFFICEOFFICE

EXAM

WAITING

EXAM

CHECK-IN/MAS

WAITING

AREA

ODVA

RELEASE OF

INFORMAITON

AGENT CASHIER

DECEDENT

AFFAIRS

LOST & FOUND

SYSTEMS REDESIGN

VETERANS JUSTICE OUTREACH OFFICE

VOC

REHAB

SPECIALIST

OFFICE

HOMELESS WALK-IN OFFICE

TRANSITION

CARE MNGNT

OFFICE

CAREGIVER

SUPPORT PROGRAM

OFFICE

CPAP

F E

C

FECFEC

S T

O R

A G

E

TELEPHONE

H.A.C.

CHECK IN

RECEPTION

TOILET

MALE

CLEAN

LINEN

MED ROOM

EXAM

EXAM

KITCHEN

LAB

EXAM EXAM

EXAMEXAM

EXAM EXAM

EXAMEXAM

OFFICE

OFFICE

OFFICE

S T

O R

A G

E

PROCEDURE/EXAM

ELEC

STORAGE

ELEC

ELEC

ELECTRICAL

H.A.C.

OFFICE OFFICE OFFICE

OFFICE

OFFICE

PACEMAKER

OFFICE

OFFICE

OFFICE

SOCIAL WORK

WAITING

T E

L E

E L

E C

TELE/DATA

ECHO

STORAGE

OFFICE

STORAGE

AUDIOLOGY

ADMIN

RESIDENTS

EXAM

PACEMAKER

OFFICE

EXAM

EXAM EXAM

EXAM

VASCULAR

LAB

VESTIBULE

SOILED

UTILITY

TRASH

S T

O R

A G

E

STORAGE

EXAMEXAM

EXAM EXAM

OFFICE

TEAM

ROOM EXAM

EXAM

EXAM

EXAM

EXAM

PUVA

ROOM

ELECTRICAL

TOILET

TOILET

H.A.C.

EXAM

NURSING

OFFICE

IT DATA

TOILET

HEARING

AID &

FITTING

STORAGE

VA EXPRESS

EXAM EXAM

S T

O R

A G

E

CARDIAC

CATH LAB #3

STORAGE SOILED

UTILITY

CONTROL ROOM

EQUIPMENT

BREAK

ROOM

AUD/SPEECH

PATH CHIEF

ELIGIBILITY

MY HEALTHY VET

COMMUNICATION

OFFICER

DAV

AMERICAN

LEGION

ANTI ROOM

TEAM

ROOM

EXAM

EXAM

EXAM

EXAM

EXAM

EXAM

EXAM

OXYGEN

STORAGECLEAN

LINEN

CLEAN UTILITY

PUVA/EXAM

EXAM

EXAM

EXAM

PROCEDURE

ROOM

EXAM

EXAM

LAB

MED

ROOM

EXAM

ROOM 7

EXAM

ROOM 8

EXAM

ROOM 9

EXAM

ROOM 10

EXAM

ROOM 5

EXAM

ROOM 4

EXAM

ROOM 3

EXAM

ROOM 2

EXAM

ROOM 1

NUTRITION

ROOM

PATIENT SERVICE

CENTER

ELIGIBILITY

SUPERVISOR

ELIGIBILITY

OFFICE

NEURO TEAM

ROOM

NEURO

OFFICE

MED ROOM

PROCEDURE

ROOM

1F132

1F1311F130

1F144

1F145

1F140

1F141

1F142

1F136

1F135a

1F135

1F134 1F133

1F137a 1F137b

1F139

1F139a

1F137

1F137c

1F137d 1F137e

1F191b

1F191a

1F187d

1F191

1F192 1F138a

F f

1F110

1F111

1F112

1F113

1F160 1F166b

1F166a

1F160a

1F161

1F166c

1F166

1F102

F

1F100

1F11…