Attachment 10 Elec 100_ 19-292.pdf
PDF 4 MB Posted
- Solicitation number
- 36C77623B0046
About this file
This solicitation is for a construction project to build a new parking garage at the Oklahoma City VA Medical Center. Key requirements include constructing a new two-level parking garage with approximately 200 parking spaces, along with associated site work and utilities. The estimated value is $10-15 million. The period of performance is 730 calendar days from NTP. The solicitation was issued on July 6, 2022 by the VA Technology Acquisition Center with responses due by August 5, 2022. The contract is set aside for Service-Disabled Veteran-Owned Small Businesses. The selected contractor will be responsible for all construction in accordance with provided drawings, specifications and performance standards.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
L
SR SURFACE RACEWAY
SS STAINLESS STEEL
SSTV SECURITY SURVEILLANCE
TELEVISION
SSW SELECTOR SWITCH
STD STANDARD
SURF SURFACE MOUNTED
SW SWITCH
SWBD SWITCHBOARD
SYM SYMMETRICAL
SYS SYSTEM
TC TIMECLOCK
TEL TELEPHONE
TEL/DATA TELEPHONE/DATA
TERM TERMINAL
TGB TELECOMM GROUND BUS BAR
TMGB TELECOMM MAIN GROUND BUS BAR
TP TWISTED PAIR
TPS TWISTED PAIR SHIELDED
TR TAMPER RESISTANT,
TELECOMM ROOM
T-STAT THERMOSTAT
TTB TELEPHONE TERMINAL BOARD
TTC TELEPHONE TERMINAL CABINET
TV TELEVISION
TYP TYPICAL
UC UNDER COUNTER
UE UNDERGROUND ELECTRICAL
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITER'S LABORATORY
UPS UNINTERRUPTIBLE POWER SUPPLY
UT UNDERGROUND TELEPHONE
UTP UNSHIELDED TWISTED PAIR
UTIL UTILITY
UV UNIT VENTILATOR OR
ULTRAVIOLET
V VOLT
VA VOLT-AMPERES
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
W WATT
W/ WITH
WH WATER HEATER
WM WIRE MANAGEMENT
W/O WITHOUT
WP WEATHERPROOF
XFMR TRANSFORMER
XFR TRANSFER
ANGLE
@ AT
DELTA
' FEET
" INCHES
# NUMBER
Φ PHASE
C CENTER LINE
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S ASSOCIATION
NFDS NON-FUSED SAFETY DISCONNECT
SWITCH
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NORMALLY OPEN
NTS NOT TO SCALE
NVR NETWORK VIDEO RECORDER
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
OIT OFFICE OF INFORMATION
TECHNOLOGY
OL OVERLOAD
PA PUBLIC ADDRESS
PACS PHYSICAL ACCESS CONTROL SYSTEM
PAMN PUBLIC ADDRESS AND MASS
NOTIFICATION SYSTEM
PB PULL BOX OR PUSHBUTTON
PCB POLYCHLORINATED BIPHENYL
PC PHOTOELECTRIC CELL
PDU RACK POWER DISTRIBUTION UNITS
PED PEDESTAL
PEND PENDANT
PF POWER FACTOR
PH PHASE
PIR PASSIVE INFRARED
PIV POST INDICATING VALVE
PNL PANEL
POE POWER-OVER-ETHERNET
PR PAIR
PRI PRIMARY
PROJ PROJECTION
PT POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE (CONDUIT)
PWR POWER
QTY QUANTITY
RCP REFLECTED CEILING PLAN
RCPT RECEPTACLE
REQD REQUIRED
RGS RIGID GALVANIZED STEEL
RM ROOM
RMS ROOT MEAN SQUARE
RTU ROOF TOP UNIT
RX REQUEST TO EXIT
SC SURFACE CONDUIT
SEC SECONDARY
SEP SERVICE ENTRANCE PROTECTION
SF SQUARE FEET/FOOT
SHT SHEET
SI INTERNATIONAL SYSTEM OF UNITS
SIM SIMILAR
SM SINGLE MODE FIBER
S/N SOLID NEUTRAL
SPEC SPECIFICATION
SPKR SPEAKER
SP SPARE
1P 1 POLE (2P, 3P, 4P, ETC.)
1PH 1 PHASE
2/C TWO-CONDUCTOR (3/C, 4/C, ETC.)
2W TWO-WIRE (3W, 4W, ETC.)
3PH 3 PHASE
A AMPERE
AAP ALARM ANNUNCIATOR PANEL
AC ABOVE COUNTER
AIR CONDITIONER
ALTERNATING CURRENT
ACC ACCESSIBLE
ACLG ABOVE CEILING
ADO AUTOMATIC DOOR OPENER
A/E ARCHITECT/ENGINEER
AF AMP FRAME
AFC AVAILABLE FAULT CURRENT (KILOAMPS)
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFI ARC FAULT CIRCUIT INTERRUPTER
AHJ AUTHORITY HAVING JURISDICTION
AHU AIR HANDLING UNIT
AIC AMPERE INTERRUPTING CAPACITY
AL ALUMINUM
ALT ALTERNATE
AMP AMPERE
APPROX APPROXIMATELY
ARCH ARCHITECT, ARCHITECTURAL
AT AMP TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AWG AMERICAN WIRE GAUGE
BAS BUILDING AUTOMATION SYSTEM
BATT BATTERY
BC BARE COPPER
BD BOARD
BLDG BUILDING
BMS BUILDING MANAGEMENT SYSTEM
BYP BYPASS
C CONDUIT
CAB CABINET
CALC CALCULATED
CAP CAPACITY
CAT CATALOG, CATEGORY
CATV COMMUNITY ANTENNA TELEVISION
CB CIRCUIT BREAKER
CCR CONTROL CONTACTOR
CCTV CLOSED CIRCUIT TELEVISION
cd CANDELA
CD CONSTRUCTION DOCUMENTS
CKT CIRCUIT
CLG CEILING
CO CONTRACTING OFFICER
COAX COAXIAL CABLE
COMM COMMUNICATION
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUATION OR CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CPT CONTROL POWER TRANSFORMER
CRI COLOR RENDERING INDEX
CT CURRENT TRANSFORMER
CTV CABLE TELEVISION
CTR CENTER
CU COPPER
CU FT CUBIC FEET
dB DECIBEL
DB DIRECT BURIAL
DC DIRECT CURRENT,
DOOR CONTACT SWITCH
DEG C DEGREES CELSIUS
DEG F DEGREES FAHRENHEIT
DEMO DEMOLISH/DEMOLITION
DEPT DEPARTMENT
DIA DIAMETER
DISC DISCONNECT
DIST DISTRIBUTION
DN DOWN
DO DOOR OPERATOR
DS SAFETY DISCONNECT SWITCH
DT DOUBLE THROW
DVR DIGITAL VIDEO RECORDER
DWG DRAWING
EC ELECTRICAL CONTRACTOR
ECB ENCLOSED CIRCUIT BREAKER
EEB EMERGENCY EXIT BUTTON
EG EQUIPMENT GROUND
EL ELECTRIC STRIKE
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR
EM EMERGENCY
EMI ELECTROMAGNETIC INTERFERENCE
EMS ENERGY MANAGEMENT SYSTEM
EMT ELECTRICAL METALLIC TUBING
EPO EMERGENCY POWER OFF
EQUIP EQUIPMENT
ESMT EASEMENT
ETR EXISTING TO REMAIN
EWH ELECTRIC WALL HEATER
ELECTRIC WATER HEATER
EX EXISTING
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FAP FIRE ALARM PANEL
FC FOOTCANDLE
FCU FAN COIL UNIT
FIXT FIXTURE
FLR FLOOR
FO FIBER OPTIC
FUDS FUSED SAFETY DISCONNECT SWITCH
FVR FULL VOLTAGE REVERSING
FVNR FULL VOLTAGE NON-REVERSING
GAL GALLON
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
GFI GROUND FAULT CIRCUIT INTERRUPTER
GND GROUND
GRS GALVANIZED RIGID STEEL (CONDUIT)
GYP BD GYPSUM BOARD
HOA HAND-OFF-AUTOMATIC
HP HORSEPOWER
HT HEIGHT
HTR HEATER
HV HIGH VOLTAGE
HVAC HEATING, VENTILATING AND AIR
CONDITIONING
IES ILLUMINATION ENGINEERING SOCIETY
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
IR INFRARED
IT INTERCOMMUNICATION
I/W INTERLOCK WITH
IWH INSTANTANEOUS WATER HEATER
J-BOX JUNCTION BOX
KV KILOVOLT
KVA KILOVOLT-AMPERE
KVAR KILOVOLT-AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
LED LIGHT-EMITTING DIODE
LF LINEAR FEET/FOOT
LM LUMEN
LRA LOCKED ROTOR AMPS
LT LIGHT
LTG LIGHTING
LTNG LIGHTNING
LV LOW VOLTAGE
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
METAL-CLAD (CONDUIT)
MCA MINIMUM CIRCUIT AMPACITY
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUGS ONLY
MM MULTI MODE FIBER
MSC MULTI SENSOR CAMERA(S)
MT MOUNT
MTR MOTOR, MOTORIZED
MTS MANUAL TRANSFER SWITCH
NA NOT APPLICABLE
NAC NETWORK APPLIANCES CONTROL PANEL
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
A1 b
E1 c d
T1
'LPN'
THE LIGHTING FIXTURE TYPE IS INDICATED BY AN UPPER CASE LETTER OR AN UPPER
CASE LETTER AND NUMBER.
THE SWITCH DESIGNATION (IF NEEDED) IS INDICATED BY A LOWER CASE LETTER.
EXAMPLE: LIGHTING FIXTURE TYPE 'A1' IS CONTROLLED BY SWITCH 'b'.
EXIT SIGNS: STEM INDICATES WALL MOUNTING. NO STEM INDICATES CEILING
MOUNTING. SHADED AREA INDICATES ILLUMINATED FACE(S). ARROW INDICATES
DIRECTIONAL ARROW ON ILLUMINATED FACE(S).
DEVICES: THE SWITCH DESIGNATION IS INDICATED BY A LOWER CASE LETTER.
THE CONTROL DEVICE DESIGNATION IS INDICATED BY A LOWER CASE LETTER.
TRANSFORMERS: THE TRANSFORMER TYPE IS INDICATED BY A NUMBER
FOLLOWING THE UPPER CASE LETTER 'T'. SEE THE TRANSFORMER SCHEDULE OR
THE SINGLE LINE DIAGRAM FOR THE TRANSFORMER DESCRIPTION AND
REQUIREMENTS.
PANELBOARDS: PANELBOARD DOORS MAY BE SHOWN TO INDICATE OPENING
SIDE OF RECESSED PANELBOARDS. SEE PANELBOARD IDENTIFICATION FOR
DESIGNATION CODES.
SHEET KEY NOTE: SEE THE SHEET KEY NOTES ON THAT SHEET FOR THE NOTE
NUMBER INDICATED IN THE HEXAGON.
HOME RUN TO BRANCH CIRCUIT PANEL: THE PANEL DESIGNATION AND CIRCUIT
DESIGNATION ARE SHOWN ADJACENT TO THE HOME RUN ARROW.
CIRCUIT BREAKER SIZES (AMPS/NUMBER OF POLES) ARE SHOWN IN THE PANEL
SCHEDULE WITH THE CORRESPONDING PANEL AND CIRCUIT DESIGNATION.
SYMBOL NOTATIONS: UPPER CASE LETTERS ADJACENT TO SYMBOLS INDICATE
A UNIT TYPE. SEE APPROPRIATE SCHEDULE OR SPECIFICATIONS.
'LPN'-1,3,5
EXAMPLE 1: WALL MOUNTED EXIT SIGN TYPE 'E1' WITH SINGLE FACE
AND DIRECTIONAL ARROW.
EXAMPLE 2: CEILING MOUNTED EXIT SIGN TYPE 'E2' WITH DOUBLE
FACE AND DIRECTIONAL ARROWS.
E2
EXAMPLE: SPLIT DUPLEX RECEPTACLE; ONE RECEPTACLE OUTLET IS
CONTROLLED BY SWITCH 'c'.
EXAMPLE: SINGLE POLE SWITCH 'd' TO CONTROL LIGHTING FIXTURES INDICATED BY 'd'.
EXAMPLE: TRANSFORMER TYPE 'T1'.
EXAMPLE: HOME RUN TO PANELBOARD 'LPN'; CIRCUITS 1, 3, 5.
# DEMOLITION KEY NOTE: SEE THE SHEET KEY NOTES ON THAT SHEET FOR THE
NOTE NUMBER INDICATED IN THE SQUARE.
1. ALL ELECTRICAL DEVICES, FIXTURES, EQUIPMENT AND FEEDERS SHALL BE INSTALLED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, THE MANUFACTURER'S RECOMMENDED PROCEDURES, ALL APPLICABLE LOCAL AND STATE CODES, AMERICANS WITH DISABILITIES ACT AND WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND VA
STANDARDS.
2. PROVIDE ADDITIONAL SUPPORT FOR DEVICES, FIXTURES, EQUIPMENT AND FEEDERS WHERE THE BUILDING
CONSTRUCTION IS NOT SUITABLE FOR DIRECT MOUNTING.
3. FIRESTOP, DRAFTSTOP, SMOKESTOP AND/OR PROTECT THE ANNULAR SPACE AROUND ALL PENETRATIONS THROUGH WALLS, PARTITIONS, FLOORS, CEILING, AND ROOFS IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL
ELECTRICAL CODE, UL LISTING REQUIREMENT AND THE APPLICABLE BUILDING CODES.
4. VERIFY CEILING SYSTEMS AND PROVIDE MOUNTING ACCESSORIES, TRIMS AND ALL REQUIRED MOUNTING HARDWARE TO
SUIT THE PARTICULAR INSTALLATION.
5. PROTECT EXISTING UNDERGROUND AND BUILDING INTERIOR UTILITIES DURING CONSTRUCTION.
6. BRANCH CIRCUIT CONDUCTORS SHALL BE 12 AWG COPPER MINIMUM.
7. COORDINATE ANY AND ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION SO AS TO AVOID CONFLICT DURING
CONSTRUCTION.
8. ALL PANELS SHALL HAVE TYPED, COMPLETED DIRECTORIES INDICATING EQUIPMENT SERVED AND ROOM NUMBER (AS INDICATED ON FINAL BUILDING ROOM SIGNAGE) OF EQUIPMENT LOCATION, OR SPARE, OR SPACE.
9. MANUFACTURER'S NAME AND MODEL NUMBER ARE GIVEN FOR DESCRIPTIVE PURPOSES, TO INDICATE A QUALITY STANDARD, AND ARE NOT INTENDED TO LIMIT PRODUCTS TO A PARTICULAR MANUFACTURER. PRODUCTS DEEMED EQUAL AND APPROVED BY THE DESIGNER WILL BE ACCEPTED. ALL PRODUCTS MUST COMPLY WITH "BUY AMERICAN ACT".
10. ALL FEEDERS AND CIRCUITRY SHALL BE TORQUED PER THE PANEL, BREAKER, AND/OR PARTICULAR EQUIPMENT
MANUFACTURER'S SPECIFICATIONS.
11. CIRCUITRY TO SWITCHES, RECEPTACLES, AND ALL OTHER DEVICES SHALL BE TERMINATED ON THE DEVICE'S SCREW
TERMINALS.
12. MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, OUTLET, FIXTURE, OR EQUIPMENT UNLESS NOTED
OTHERWISE.
13. ALL WIRE TERMINATIONS SHALL BE RATED FOR 75 DEGREES C.
14. ALL CONDUCTORS SHALL HAVE THHN/THWN INSULATION, UNLESS OTHERWISE NOTED.
15. ALL CONDUIT SHALL BE RGS OR EMT UNLESS OTHERWISE NOTED. FMC CONDUIT SHALL BE USED ON VIBRATING EQUIPMENT (MAXIMUM LENGTH OF 6 FEET). PVC SHALL BE USED FOR UNDERGROUND CONDUIT OR WHERE CONCRETE- ENCASED. WHERE VIBRATING EQUIPMENT IS LOCATED OUTSIDE, LFMC CONDUIT SHALL BE USED (MAXIMUM SIX FEET) FOR
FINAL CONNECTIONS.
16. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT SHALL BE LABEL LISTED BY AN APPROVED THIRD
PARTY TESTING AGENCY.
17. FOR ALL LED FIXTURES, THE FIXTURE MUST BE CAPABLE OF SELF-RESETTING TO THE SWITCHED/CONTROLLED STATE DURING ANY FLUCTUATION IN POWER SUPPLY WHERE AUTOMATIC PROTECTIVE MEASURES DISABLE THE LED LAMPS.
PROVIDE A LETTER OR STATEMENT FROM THE MANUFACTURER, OR OTHER ACCEPTABLE PROOF, THAT ALL LED FIXTURES, WITH OR WITHOUT BROWNOUT PROTECTION, WILL RETURN TO THE SWITCHED/CONTROLLED STATE AUTOMATICALLY.
PROVIDE STATEMENT WITH THE FIXTURE SUBMITTALS.
18. IN CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG THE CONTRACT DRAWINGS, THE BETTER QUALITY, MORE STRINGENT REQUIREMENTS OR GREATER QUANTITY OF WORK , AS DETERMINED BY THE GOVERNMENT, SHALL BE
PROVIDED.
19. COMPRESSION COUPLINGS SHALL BE USED. NO SET SCREW FITTINGS ARE ALLOWED.
20. MINIMUM CONDUIT SIZE TO BE USED IS 1 1/4".
21. GENERAL CONTRACTOR TO RELOCATE MEDIUM VOLTAGE LINE - PAID FOR BY AN ALLOWANCE UNDER THIS CONTRACT.
COORDINATE WITH UTILITY AND VA CONTRACTING OFFICER OR CONTRACTING OFFICER'S REPRESENTATIVE.
120V DUPLEX RECEPTACLE
120V DUPLEX RECEPTACLE EMERGENCY OUTLET
AND COVER PLATE SHALL BE RED IN COLOR
120V QUADRUPLEX RECEPTACLE
120V QUADRUPLEX RECEPTACLE EMERGENCY
OUTLET AND COVER PLATE SHALL BE RED IN COLOR
SYMBOL HEIGHT DESCRIPTION
18"
18"
18"
18"
SPECIAL RECEPTACLE
208V DUPLEX RECEPTACLE18"
18"
RECEPTACLE MODIFIERS:
AC: 3" ABOVE COUNTERTOP/BACKSPLASH
GFI: GROUND FAULT CURRENT INTERRUPTER
WP: WEATHERPROOF ENCLOSURE
DED: DEDICATED CIRCUIT
JUNCTION BOX, WALL MOUNTED, PURPOSE AS NOTED
DISCONNECT SWITCH NON-FUSED
DISCONNECT SWITCH FUSED
SINGLE POLE WALL SWITCH: 48" AFF STANDARD UNO
AS
NOTED
72" TOP
72" TOP
SWITCH MODIFIERS:
M: MOTOR-RATED
48"
ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.
TOP: HEIGHT TO TOP OF DEVICE
ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.
EQUIPMENT CONNECTION
AS
NOTED
E
CLNG
J
J
J
JUNCTION BOX, CEILING MOUNTED, PURPOSE AS
NOTED
JUNCTION BOX, FLOOR MOUNTED, PURPOSE AS
NOTED
PARKING GARAGE LIGHT
4' STRIP LIGHT
SYMBOL
HEIGHT
AFF * DESCRIPTION
--- 4' LINEAR SURFACE MOUNTED
WALL PACK
10'-0"
BOTTOM
LIGHTED BOLLARD---
EXIT SIGN - WALL MOUNTED
EXIT SIGN - CEILING MOUNTED---
7'-5"
BOTTOM
EMERGENCY LIGHT BATTERY
OPERATED - WALL MOUNTED
7'-6"
CENTER
4' LINEAR - WALL MOUNTED
7'-0"
CENTER
SINGLE POLE WALL SWITCH
SWITCH MODIFIERS:
OS: OCCUPANCY SENSOR, DUAL TECHNOLOGY
VS: VACANCY SENSOR, DUAL TECHNOLOGY
D: LINE VOLTAGE DIMMER
T: DIGITAL TIMER
K: KEYED
3: 3 WAY
48"
CENTER
OCCUPANCY SENSOR, DUAL
TECHNOLOGY - CEILING MOUNTED
OCCUPANCY SENSOR, DUAL
TECHNOLOGY - WALL/CORNER MOUNTED
OS
OS
* - ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE
LISTED HERE.
LIGHT LEVEL SENSOR, SINGLE ZONE
DIMMING CLOSED LOOP - CEILING MOUNTED
---LS
TRIPLE HEAD AREA LIGHT - POLE MOUNTEDPOLE
DUAL HEAD AREA LIGHT - POLE MOUNTEDPOLE
SINGLE HEAD AREA LIGHT - POLE MOUNTEDPOLE
PHOTOCELLPC
1. PROVIDE COMMUNICATIONS DEVICES AND EQUIPMENT IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, MANUFACTURER'S RECOMMENDED PROCEDURES, ALL APPLICABLE LOCAL AND STATE CODES, AMERICANS WITH DISABILITIES ACT, LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, BICSI STANDARDS, AND VA
STANDARDS.
2. PROVIDE ADDITIONAL SUPPORT FOR DEVICES AND EQUIPMENT WHERE BUILDING CONSTRUCTION IS NOT
SUITABLE FOR DIRECT MOUNTING.
3. FIRESTOP, DRAFTSTOP, SMOKESTOP OR PROTECT ANNULAR SPACE AROUND PENETRATIONS THROUGH WALLS, PARTITIONS, FLOORS, CEILINGS, AND ROOF IN ACCORDANCE WITH REQUIREMENTS OF NFPA 70, UL
LISTING REQUIREMENT AND APPLICABLE BUILDING CODES.
4. PROVIDE CABLING THAT COMPLIES WITH LATEST EDITION OF TELECOMMUNICATIONS DISTRIBUTION
METHOD MANUAL AND ANSI/TIA/EIA PUBLICATIONS.
5. COMPLY WITH ANSI/TIA/EIA 758 AND 607B OR 607A - GROUNDING AND BONDING REQUIREMENTS FOR
TELECOMMUNICATIONS IN COMMERCIAL BUILDING.
6. COMPLY WITH ANSI/TIA/EIA 568B - COMMERCIAL BUILDING TELECOMMUNICATIONS WIRING STANDARD.
7. COMPLY WITH ANSI/TIA/EIA 569B - COMMERCIAL BUILDING STANDARD FOR TELECOMMUNICATIONS
PATHWAYS AND SPACES.
8. COMPLY WITH NFPA 70 NATIONAL ELECTRICAL CODE.
9. COMPLY WITH NFPA 99 HEALTHCARE FACILITIES CODE.
10. COMPLY WITH NFPA 101 LIFE SAFETY CODE.
11. COORDINATE WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION.
12. MANUFACTURER'S NAME AND MODEL NUMBER ARE GIVEN FOR DESCRIPTIVE PURPOSES, TO INDICATE A QUALITY STANDARD, AND ARE NOT INTENDED TO LIMIT PRODUCTS TO A PARTICULAR MANUFACTURER.
PRODUCTS DEEMED EQUAL AND APPROVED BY THE COR WILL BE ACCEPTABLE. COMPLY WITH "BUY
AMERICAN ACT".
13. MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, BOXES, OUTLET, OR EQUIPMENT UNLESS
NOTED OTHERWISE.
14. PROVIDE RGS OR EMT CONDUIT UNLESS OTHERWISE NOTED.
15. PROVIDE MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT LABEL LISTED BY APPROVED THIRD PARTY
TESTING AGENCY.
16. NOTIFY COR REGARDING DISCREPANCY BETWEEN PLANS AND SPECIFICATIONS FOR CLARIFICATION. THE
MORE STRINGENT OF THE THEM SHALL TAKE PRECEDENCE.
17. FOR LOCATION (CORRIDOR, ROOM OR ADJACENT SPACE) WITH TWO OR MORE VISIBLE FIRE ALARM NOTIFICATION APPLIANCES WITHIN THE FIELD OF VIEW, PROGRAM VISIBLE TO FLASH IN SYNCHRONIZATION.
18. PROVIDE TIA/EIA CAT 6A COPPER OUTLETS AND CONNECTORS.
19. ALL WORK AREA OUTLETS SHALL BE 8 PIN, CAT 6A KEYSTONE JACK WIRED PER T568A OR T568B AS
DIRECTED BY THE VA COR.
20. LABEL DEVICES IN ACCORDANCE WITH LATEST ANSI/TIA 606A OR 606B EDITION AS WELL AS THE STANDARDS
SET FORTH BY THE VA HOSPITAL OIT.
21. PROVIDE A MINIMUM OF 12" CLEARANCE ABOVE THE CABLE TRAY PER TIA/EIA 569.B PARAGRAPH 4.5.6.2.
22. VA WILL CONDUCT A WAP SURVEY AND PROVIDE THE SURVEY TO THE CONTRACTOR. INSTALL CABLING AND
EQUIPMENT IN ACCORDANCE WITH THE SURVEY. COORDINATE WITH COR/OIT.
23. ALL CABLING SHALL BE INSTALLED IN CONDUIT.
DATA OUTLET - 2-4 PR UTP
SYMBOL HEIGHT DESCRIPTION
18"
DATA OUTLET - 4-4 PR UTP18"
DATA OUTLET - 1-4 PR UTP
TELCO OUTLET - 1-4 PR UTP
18"
48"
WIRELESS ACCESS POINT - 2-4 PR UTP
WALL PHONEW 48"
CEILING
ELECTRONIC LOCKING MECHANISM
DOOR CONTACT
REQUEST FOR EXIT SENSOR
CARD READER
(K - KEYPAD)
48"CR
ES
DC
RX
DOOR
DOOR
ABOVE
DOOR
PHYSICAL ACCESS CONTROL SYSTEMPACS 6' TO TOP
ELECTRONIC PANIC HARDWAREEP
DO DOOR OPERATOR
DOOR
DOOR
48" EMERGENCY EXIT BUTTON TO RELEASE DOOR (EEB)
SSTV DOME CAMERA FIXED
SSTV DOME CAMERA MULTI SENSOR - PANORAMIC
FOUR POST OIT EQUIPMENT RACK
SSTV EQUIPMENT CABINETSSTV
LADDER CABLE TARY
GROUND BUS
FLOOR
FLOOR
ABOVE
CEILING
18"
4'x8'x3/4" FIRE RATED TTB8"
FLOOR TWO POST OIT EQUIPMENT RACK
CEILING MOUNTED SPEAKERSCEILING
WALL MOUNTED SPEAKERS96"
S
S
ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.
ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.
SEE DRAWINGS FOR MORE INFORMATION.
NOTE: NOT ALL SYMBOLS ARE USED.
MS
F
48" AUTOMATIC DOOR OPENERADO
EMERGENCY BLUE LIGHT PHONE
WALL MOUNTED
EMERGENCY BLUE LIGHT PHONE
PEDESTAL MOUNTED
48" B
B
SYMBOL HEIGHT DESCRIPTION
ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.
TOP: HEIGHT TO TOP OF DEVICE
ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.
FIRE ALARM SMOKE DETECTOR
FIRE ALARM HEAT DETECTOR
FIRE ALARM PULL STATIONF
F
FIRE ALARM SPEAKER
FIRE ALARM STROBE
FIRE ALARM PULL SPEAKER AND STROBE
42"
90"
90"
90"
FIRE ALARM CONTROL PANELFACP
XX - CANDELA
XX - CANDELA
XX - WATTAGEF
S
F
S
FIRE ALARM ANNUNCIATOR PANELFAA
72"
72"
SD
HD
FLOW SWITCH WITH ADDRESSABLE MONITOR MODULE
TAMPER SWITCH WITH ADDRESSABLE MONITOR MODULE
SYMBOL HEIGHT DESCRIPTION
1. PROVIDE FIRE ALARM SYSTEM AND COMPONENTS COMPLYING WITH THE LATEST:
A. NFPA 13- STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS.
B. NFPA 14- STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEM.
C. NFPA 20- STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION.
D. NFPA 70 NATIONAL ELECTRICAL CODE.
E. NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE.
F. NFPA 90A STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS.
G. NFPA 101 LIFE SAFETY CODE.
H. VA FIRE PROTECTION DESIGN MANUAL.
I. ANSI S3.41 AUDIBLE EMERGENCY EVACUATION SIGNAL.
2. FIRE ALARM SYSTEM SHALL COMPLY WITH FACTORY MUTUAL RESEARCH CORPORATION (FM).
3. PROVIDE FIRE ALARM WIRING IN CONDUIT, FACTORY PAINTED RED.
4. THE FIRE ALARM SYSTEM VENDOR/CONTRACTOR SHALL TERMINATE, TEST AND PROGRAM ALL NEW FIRE ALARM DEVICES.
COORDINATE WITH COR.
5. CONNECT SPRINKLER SYSTEM SUPERVISORY DEVICES TO THE FIRE ALARM SYSTEM. COORDINATE LOCATION WITH THE
SPRINKLER CONTRACTOR.
6. PROVIDE RELAY CONTROL MODULES FOR PACS, COORDINATE WITH PHYSICAL ACCESS CONTROL SYSTEM (PACS), CONTRACTOR AND COR.
7. THE OPERABLE PART OF A MANUAL ACTUATED ALARM INITIATING DEVICE SHALL BE NOT LESS THAN 42" (1.07M) AND NOT
MORE THEN 48" (1.22M) FROM FINISH FLOOR.
8. ALL FIRE ALARM DEVICES IN THE PARKING GARAGE SHALL BE WEATHER PROOF.
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:4
:3
P M
C U s e rs
\a m a s o n
\D o c u m e n ts
\E
-2
-O
K C
P a rk in g G a ra g e a m a s o n a c g -p a .c o m
.r v t
E-001
ELECTRICAL GENERAL NOTES,
SYMBOL LEGENDS, AND
ABBREVIATIONS
1 16KLC
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
JULY 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
JKM
ELECTRICAL AND TECHNOLOGY ABBREVIATIONS LIST
ELECTRICAL SYMBOL NOTES
ELECTRICAL GENERAL NOTES
ELECTRICAL SYMBOL LEGENDLIGHTING SYMBOL LEGEND
TECHNOLOGY GENERAL NOTES
TECHNOLOGY SYMBOL LEGEND
FIRE ALARM SYMBOL LEGEND
FIRE ALARM GENERAL NOTES
DocuSign Envelope ID: DE6B1966-C688-4097-B859-109EA506307E
7/6/2022
DN
PROPOSED
PARKING GARAGE
LP LP
LP
LP
LP
LP
L P
E T
E T
E T
E T
E T
E T
S W G R
E
E
P
LB
P
LB
B u s h
B u s h
E le c
P
LB
E le c
P
LB
E le c
P
LB
E le c
P
LB
E le c
P
LB
E le c
P
LB
E le c
P
LB
E le c
P
LB
E le c
P
LB
C o m m s
C o m m
P
LB
C o m m
P
LB
C o m m s
P
LB
C o m m s
P
LB
In d ia n
N a tio n s
T e le
In d ia n
N a tio n
T e le
C o m m s
P
LB
E
J
PC
CR
CRJ
E E
E
M
M
E
E
E
E
E
NEW PAD
MOUNTED
SERVICE
TRANSFORMER
P1
P1
NEW
GENERATOR
IT
ELEC
SECURITY
FACP
NEW
SECTIONALIZING
SWITCH
EXISTING
MEDIUM
VOLTAGE
SWITCHGEAR
'H1'- 2
PANEL 'GS'
PACS
'GS'- 1,3,5
'H1'- 23
WP
WP
'E1L'- 38,40,42
'E1L'- 19
'E1L'- 21
'GS'- 13,15,17
'GS'- 19,21,23
'GS'- 25,27,29
'E1L'- 37,39,41
'GS'- 7,9,11
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:4
:0
P M
C U s e rs
\a m a s o n
\D o c u m e n ts
\E
-2
-O
K C
P a rk in g G a ra g e a m a s o n a c g -p a .c o m
.r v t
ES101
ELECTRICAL SITE PLAN
2 16KLC
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
JULY 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
JKM
Scale: No Scale
ELECTRICAL SITE PLAN
N
SCOPE OF WORK
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
N O
R T
H0 4 8 16
A. ALL EXTERIOR LIGHT FIXTURES SHALL BE
CONTROLLED BY INTEGRAL PHOTOCELLS.
B. FOR ANY ITEMS WHICH CROSS OR APPROCH THE
OG&E RELOCATED UTILITY LINE, A MINIMUM OF
24" SEPARATION, HORIZONTAL OR VERTICAL,
MUST BE MAINTAINED FROM THIS RELOCATED
LINE.
1 CAMERA COVERING TRANSFORMER.
REFERENCE E-101.
2 PROVIDE TELECOM HANDHOLE. SEE DETAIL
11/E-502.
3 SEE ES102 FOR MORE INFORMATION.
4 PROVIDE TWO 4" CONDUITS WITH FIBER FOR
DATA AND PACS. SEE RISER DETAIL 3/E-503
FOR MORE INFORMATION.
5 PROVIDE TWO 2" CONDUITS.FOR FIRE ALARM
FIBER LOOP. SEE DETAIL 1/E-503 FOR MORE
INFORMATION.
6 PROVIDE MEDIUM VOLTAGE UNDERGROUND
500 kCMIL 15kV RATED FEEDER FROM
MEDIUM VOLTAGE SWITCHGEAR, CONCRETE
ENCASED IN 3" CONCRETE ENCASEMENT
(TWO 4" CONDUITS, ONE IS SPARE)
7 PROVIDE TWO 4" CONDUITS WITH
PULLCORDS STUBBED OUT 5'-0" FROM THE
SECTIONALIZING SWITCH FOR FUTURE.
8 PROVIDE MEDIUM VOLTAGE UNDERGROUND
500 kCMIL 15kV RATED FEEDERS IN
CONDUITS, TWO 4" CONDUITS (ONE SPARE)
TO SERVE NEW PAD MOUNTED
TRANSFORMER.
9 LOCATION OF GUARD SHACK.
10 LOCATION OF GATE CONTROLLER. PROVIDE
120V EMERGENCY POWER FROM PANEL ''GS'.
VERIFY REQUIREMENTS WITH
MANUFACTURER.
11 NEW CARD READER ON A PEDESTAL FOR THE
GATE. RUN 1" CONDUIT WITH CABLING TO
THE PACS PANEL. PEDESTAL SHALL BE 48"
HEIGHT, B.O.D.: ZORO GG33430I OR EQUAL.
12 PROVIDE ONE 2" CONDUIT WITH CABLING.
13 AUTOMATIC RETRACTABLE BOLLARDS;
208V/3PH, 5 HP; PROVIDE 3-8 AWG, 8 AWG EG
IN 1" CONDUIT.
14 EXISTING UNDERGROUND MEDIUM VOLTAGE
UTILITY LINE. GC TO RELOCATE MEDIUM
VOLTAGE LINE – PAID FOR BY AN
ALLOWANCE UNDER THIS CONTRACT.
COORDINATE WITH UTILITY AND VA CO/COR.
15 PROPOSED ROUTE OF NEW UNDERGROUND
MEDIUM VOLTAGE UTILITY DUCT BANK. SEE
CIVIL DRAWING CU101. GC TO RELOCATE
MEDIUM VOLTAGE LINE – PAID FOR BY AN
ALLOWANCE UNDER THIS CONTRACT.
COORDINATE WITH UTILITY AND VA CO/COR.
16 PROVIDE 1" CONDUIT WITH CONTROL CABLES
FROM CONTROL PANEL IN GUARD SHACK TO
RETRACTABLE BOLLARDS. VERIFY
REQUIRMENTS WITH SYSTEM
MANUFACTURER.
17 PROVIDE AND INSTALL LICENSE PLATE
RECOGNITION (ALPR) MULTISENSOR CAMERA
ON LPR POLE. COORDINATE EXACT
MOUNTING HEIGHT AT TIME OF
INSTALLATION. CAMERA SHALL BE INSTALLED
AS THIRD AUTHENTICATION IN THE TRIPLE
AUTHENTICATION PROCESS. RUN CONDUIT
AND WIRE TO GUARD SHACK. SEE DETAIL 7
ON E-503.
18 PROVIDE AND INSTALL ACCESS CONTROL TO
THE GATE ARM CONTROL SYSTEM AND
INTEGRATE WITH THE OPERATION
CONTROLS. INTEGRATIONS SHALL ALLOW
THE ACCESS CONTROL SYSTEM TO CONDUCT
THE FOLLOWING: POSITION MONITORING;
REMOTE OPEN; OPEN SCHEDULE, MAIN GATE
STATE FOR SCHEDULED PERIOD AND OPEN
ON AUTHORIZED TRIPLE AUTHENTICATION.
19 PROVIDE CIRCUIT FOR LIGHTED BOLLARDS.
PROVIDE PHOTOCELL FOR BOLLARD
CONTROL. COORDINATE SPECIFICATIONS
AND REQUIREMENTS WITH CIVIL.
20 POWER FOR GENERATOR FUEL RETURN
PUMP DTRP-1. PROVIDE FUSIBLE NEMA 3R
RATED DISCONNECT MOUNTED ON SELF
SUPPORTING ANGLE IRON FRAME NEAR
GENERATOR.
21 SEE DETAIL 12/E-501.
22 EXISTING POWER. SECURE MEDIUM VOLTAGE
SWITCHGEAR. UTILIZE ONE SPARE BREAKER
COMPARTMENT TO SERVE NEW
SECTIONALIZING SWITCH, WITH NEW 400A
BREAKER TO SERVE NEW 15KV FEEDER TO
SECTIONALIZING SWITCH.
23 EXISTING ABOVE GROUND DIESEL FUEL
TANKS TO SERVE NEW DIESEL GENERATOR.
24 SECURITY GATE; PROVIDE 3-8 AWG, 1-8 AWG
EG IN 3/4" CONDUIT
25 LOCATE GENERATOR ANNUNCIATOR PANEL
INSIDE GUARD SHACK. COORDINATE
LOCATION WITH AVAILABLE SPACE ON WALL
AND WITH VA.
26 POWER FOR GENERATOR MAIN TANKS PUMP
FTP-1. PROVIDE FUSIBLE NEMA 3R RATED
DISCONNECT MOUNTED ON SELF
SUPPORTING ANGLE IRON FRAME NEAR
GENERATOR.
27 RELOCATED POLE LIGHT, RE-CONNECT TO
EXISTING ELECTRICAL CIRCUIT AND
CONTROLS. COORDINATE WITH CIVIL
DRAWINGS. DEMO EXISTING POLE BASE.
PROVIDE NEW POLE BASE AS REQUIRED AT
RELOCATED LOCATION. SEE DETAIL 12/E-501.
PROPOSED
PARKING GARAGE
EXISTING VAMC BUILDING
EXISTING PARKING GARAGE
EXISTING
MCR
9A 123A
EXISTING
NETWORK ROOM
BA112E
EXISTING
CCTV
1A113
SEE ES101
SEE ES101
EXISTING
IT/SECURITY
1G130
EXISTING
FIRE ALARM ROOM
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:4
:0
P M
C U s e rs
\a m a s o n
\D o c u m e n ts
\E
-2
-O
K C
P a rk in g G a ra g e a m a s o n a c g -p a .c o m
.r v t
ES102
OVERALL ELECTRICAL CAMPUS PLAN
3 16KLC
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
JULY 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
JKM
1 PROVIDE TWO 4" CONDUITS WITH FIBER FOR
DATA AND PACS. SEE RISER DETAIL 3/E-503
FOR MORE INFORMATION.
2 PROVIDE TWO 2" CONDUITS.FOR FIRE ALARM
FIBER LOOP. SEE DETAIL 1/E-503 FOR MORE
INFORMATION.
3 PROVIDE TELECOM HANDHOLE. SEE DETAIL
11/E-502.
4 LOCATION OF EXISTING FACP.
5 BORE CONDUIT UNDER DRIVEWAY AND
SIDEWALK. COORDINATE WITH COR.
6 RUN FIRE ALARM CONDUITS AND FIBER
CABLING IN CRAWLSPACE. VERIFY EXACT
ROUTING.
7 RUN CONDUIT AND WIRE EITHER TO THE
BASEMENT CEILING AND THEN AS SHOWN
ON DRAWINGS, OR RUN CONDUIT EXPOSED
ON WALL TO ABOVE CEILING AND THEN AS
SHOWN ON DRAWINGS.
Scale: No Scale
OVERALL ELECTRICAL CAMPUS PLAN
F
S
2W 177 Cd
F
S 2W
177 Cd
F
S 2W
177 Cd
F
S 2W
177 Cd
F
S 2W
177 Cd
F
S 2W
177 Cd
C C
DD
EE
GG
E-401
E-402
IT
ELEC
SECURITY
E3
FUTURE
ELEV
E2
ELEV
E1
ELEV
ELEV EQUIP 101
MECHS1
STAIR
S2
STAIR
E-402
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
AA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
AA
A
A
A
A
A
A
A
A
A
A
A
E2
E1
E2
E2
E2
E2 E2
E2
E2
MS 270MS 270
MS 270
A
A
E-402
E-401
PANEL 'L1'
PANEL 'LS1'
PANEL 'E1'
PANEL 'H1'
MS 360
MS 360 MS 360
MS 360
MS 180
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM EM
EM
EM
EM
EM
EM
EM
'H1'- 9
A
A
A
A
AAA
F
F
F
A
'H1'- 13
'H1'- 5
'LS1'- 5
F
F
'H1'- 11
MS 360
MS 360
A
A
A
A
A
A
A
A
PANEL 'E1L'
F
'H1'- 3
MS 180
EM
EM
EM
AA
BB
FF
5.2
5.2
EM
'H1'- 7
2.2
2.2
B.6B.6
3.1
3.1
3.2
3.2
3.3
3.3
1.6
1.6
'LS1'- 5
'LS1'- 5
'H1'- 8
'LS1'- 5
'LS1'- 5
'H1'- 8
PANEL
'MDP'
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
/1
/2
:4
:4
P M
C U s e rs
\a m a s o n
\D o c u m e n ts
\E
-2
-O
K C
P a rk in g G a ra g e a m a s o n a c g -p a .c o m
.r v t
E-101
LEVEL 1 ELECTRICAL PLAN
4 16KLC
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
JULY 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
JKM
Scale: No Scale
LEVEL 1 ELECTRICAL PLAN
N O
R T
H0 4 8 16
1 CIRCUIT ONLY THE NOTED TYPE A LIGHT
FIXTURES AS NOTED CONTROLLED VIA
ASTRONOMICAL TIME CLOCK AND
PHOTOCELL TO TURN ON AT DAWN AND OFF
AT DUSK. CONTRACTOR TO PROVIDE TIME
CLOCK AS REQUIRED. SEE DETAIL 9/E-501.
2 NEW PAD MOUNTED SERVICE
TRANSFORMER.
N
SCOPE OF WORK
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
A. PROVIDE SSTV CAMERAS, CONDUITS, CABLE,
FIBER TRANSCEIVER, AND POWER SUPPLIES FOR
A COMPLETE SSTV SSYTEM.
B. PROVIDE FIRE ALARM DEVICES, EQUIPMENT,
CONDUIT AND WIRE FOR A COMPLETE FIRE
ALARM SYSTEM.
C. PROVIDE FIBER OPTIC CABLES AND COPPER
CABLES IN CONDUIT AS SHOWN.
D. SYSTEM SHALL BE TESTED AND CERTIFIED
AFTER INSTALLATION.
E. ALL PARKING GARAGE LIGHTING FIXTURES, TYPE
A, WITH PROGRAMMABLE MULTI-LEVEL DRIVER,
SHALL HAVE INTEGRAL PASSIVE INFRARED
OCCUPANCY SENSOR AND AMBIENT LIGHT
SENSOR ENABLED. WHEN AMBIENT LIGHT LEVEL
EXCEEDS 12 FOOTCANDLES, LIGHTS SHALL
REMAIN OFF REGARDLESS OF OCCUPANCY.
WHEN LIGHT LEVELS FALL BELOW 7
FOOTCANDLES, LIGHT SHALL REMAIN IN LOW
MODE DURING NO OCCUPANCY AND SWITCH TO
HIGH MODE AFTER OCCUPANCY IS DETECTED.
CONFIRM PROGRAMMING SETTINGS WITH COR
PRIOR TO COMPLETION.
F. ALL EMERGENCY LIGHTING (EM) SHALL HAVE
BOTH NORMAL AND EMERGENCY POWER.
DURING EMERGENCY CONDITION THE
GENERATOR TRANSFER DEVICE SHALL DETECT
NORMAL POWER VOLTAGE LOSS, TRANSFER TO
EMERGENCY POWER AND RETURN TO FULL-
OUTPUT UPON LOSS OF CONTROL SIGNAL. SEE
DETAIL 8/E-501. NORMAL POWER CIRCUIT AS
SHOWN ON PLAN. LIFE SAFETY EMERGENCY
POWER CIRCUIT AS SHOWN ON PLAN.
G. ALL EXTERIOR LIGHT FIXTURES SHALL BE
CONTROLLED BY INTEGRAL PHOTOCELLS.
H. ALL 120 VOLT 20 AMP 1-POLE BRANCH CIRCUIT
CONDUCTORS SHALL BE AS FOLLOWS, UNLESS
NOTED OTHERWISE:
a. RUNS LESS THAN 150' SHALL BE MINIMUM
2-12 AWG, 1-12 AWG EG IN 3/4" C.
b. RUNS BETWEEN 150'-250' SHALL BE
MINIMUM 2-10 AWG, 1-10 AWG EG IN 3/4"
C.
c. RUNS GREATER THAN 250' SHALL BE
MINIMUM 2-8 AWG, 1-8 AWG EG IN 3/4" C.
B J
C C
DD
EE
GG
E-401
E-402
P2 P2
P2
P2
P2 P2
P2
P2
F
MS 270
MS 270
MS 270
MS 270
'H1'- 4
STAIR
S1
ELEV
E1
ELEV
E2
FUTURE
ELEV
E3
ELEV
LOBBY
'E1L'- 5
AA
BB
FF
5.2
5.2
EM
EM
EM
EM
'LS1' - 1
'LS1' - 1
'LS1' - 1
'LS1' - 1
EM
'LS1'- 1
2.2
2.2
B.6B.6
3.1
3.1
3.2
3.2
3.3
3.3
1.6
1.6
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
/6
/2
:1
:2
A
M C
U s e rs
\a m a s o n
\D o c u m e n ts
\E
-2
-O
K C
P a rk in g G a ra g e a m a s o n a c g -p a .c o m
.r v t
E-102
LEVEL 2 ELECTRICAL PLAN
5 16KLC
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
JULY 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
JKM
N O
R T
H0 4 8 16
Scale: No Scale
LEVEL 2 ELECTRICAL PLAN
N
SCOPE OF WORK
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
A. PROVIDE SSTV CAMERAS, CONDUITS, CABLE,
FIBER TRANSCEIVER, AND POWER SUPPLIES FOR
A COMPLETE SSTV SSYTEM.
B. PROVIDE FIRE ALARM DEVICES, EQUIPMENT,
CONDUIT AND WIRE FOR A COMPLETE FIRE
ALARM SYSTEM.
C. PROVIDE FIBER OPTIC CABLES AND COPPER
CABLES IN CONDUIT AS SHOWN.
D. SYSTEM SHALL BE TESTED AND CERTIFIED
AFTER INSTALLATION.
E. SEE STRUCTURAL PLANS FOR POLE BASE
DETAILS. PROVIDE POLE BASES WITH
SUFFICIENT CONDUIT FOR WIRING REQUIRED
PLUS ONE ADDITIONAL 1" CONDUIT STUBBED
OUT AND CAPPED AS SPARE. COORDINATE WITH
PRECAST PROVIDER FOR CONDUIT QUANTITY
AND SIZES AND POLE ANCHORS. WIRING WITHIN
POLES MUST COMPLY WITH NEC 800.133(A)(2)
AND 700.10(B). ROUTE CONDUCTORS WITHIN
POLES IN EMT OR LFNC AS REQUIRED.
F. ALL EMERGENCY LIGHTING (EM) SHALL HAVE
BOTH NORMAL AND EMERGENCY POWER.
DURING EMERGENCY CONDITION THE
GENERATOR TRANSFER DEVICE SHALL DETECT
NORMAL POWER VOLTAGE LOSS, TRANSFER TO
EMERGENCY POWER AND RETURN TO FULL-
OUTPUT UPON LOSS OF CONTROL SIGNAL. SEE
DETAIL 8/E-501. NORMAL POWER CIRCUIT AS
SHOWN ON PLAN. LIFE SAFETY EMERGENCY
POWER CIRCUIT AS SHOWN ON PLAN.
G. ALL EXTERIOR LIGHT FIXTURES SHALL BE
CONTROLLED BY INTEGRAL PHOTOCELLS.
H. ALL 120 VOLT 20 AMP 1-POLE BRANCH CIRCUIT
CONDUCTORS SHALL BE AS FOLLOWS, UNLESS
NOTED OTHERWISE:
a. RUNS LESS THAN 150' SHALL BE MINIMUM
2-12 AWG, 1-12 AWG EG IN 3/4" C.
b. RUNS BETWEEN 150'-250' SHALL BE
MINIMUM 2-10 AWG, 1-10 AWG EG IN 3/4"
C.
c. RUNS GREATER THAN 250' SHALL BE
MINIMUM 2-8 AWG, 1-8 AWG EG IN 3/4" C.
I. PROVIDE MASTER-LABEL LISTED LIGHTING
PROTECTION SYSTEM. REFERENCE DETAIL
SHEETS FOR GROUNDING AND LIGHTNING
PROTECTION AIR DETAILS.
1 PROVIDE PEDESTAL TYPE EMERGENCY
PHONE WITH BLUE LIGHT WITH 120V
EMERGENCY POWER. SEE DETAIL 7/E-502.
2 CAMERAS TO BE MOUNTED ON THE LIGHT
POLE, TWO FEET BELOW FIXTURE. RUN
CABLE IN CONDUIT INSIDE LIGHT POLE.
3 PROVIDE GROUND CONDUCTOR IN CONDUIT
CAST IN CONCRETE SUPPORTING GARAGE.
COORDINATE WITH STRUCTURAL.
C
C
C
C
C C
C
C
C
C C
C C
C C
C C
C C
C
C
C
C
C
C
C
I C
IC
SP
SP
C C
C
C
C
C
C
CC
C C
C O
N C
R
A M
P C
O N
C R
A M
P
DN
UP
STAIR #3
AREAWAY
AREAWAYAREAWAY
AREAWAY
AREAWAY
STAIR #4
AREAWAY AREAWAY
ELEV. P-3
ELEV. P-4
ELEV. P-5
ELEV. P-6
ELEV. P-2
ELEV. P-1
CHASE
STAIR #8
STAIR #7
ELEV. P-12
ELEV. P-11
P-10
ELEVATOR
P-9
ELEVATORELEVATOR
P-8
ELEVATOR
P-7
CHASE
STAIR #1
STAIR #2
P
IP
E C
H A
S E
STAIR #3
STAIR #4
STAIR 10
STAIR #6
STAIR
#15
U P
F
IL
E S
S H
E L
V
IN
G
BOOK
CASE
S H
E L
V
IN
G S
H E
L V
IN
G
S H
E L
V
IN
G S
H E
L V
IN
G
SHELVING SHELVING SHELVING
B A
T T
E R
Y B
A C
K U
P
B A
T T
E R
Y B
A C
K U
P
S
S
S
S
S
S
S
S4S1 S2 S3 S5
S
S
B9B
B3
B2
B5
B4
B1
B10
B13
B11
B12
S
B
B
B
B
DROP
C O
N C
R E
T E
B E
A M
H E
IG
H
T
F .F
T
O A
P P
R O
X
A .F
.F
C O
N C
R E
T E
B E
A M
H E
IG
H
T
F .F
T
O A
P P
R O
X
A .F
.F
C O
N C
R E
T E
B E
A M
H E
IG
H
T
F .F
T
O A
P P
R O
X
A .F
.F
CONCRETE BEAM HEIGHT: F.F. TO APPROX. 58" A.F.F.
563_ "H X 17 1_
"D WALL563_
"H X 18"D WALL
3_4 "H X
"D
W A
L L
621_
"H X 13"D WALL12"D12"D
CBF 2
CBF 14
C B
F
C B
F
CBF 8
CBF 10
C B
F
C B
A
C B
B
CBB 2
C B
B
C B
B
C B
B
CBB 5 CBB 4
C B
C
-1 A
CBA 3
C B
F
CBA 1 CBA 2
C B
A
C B
F
CBF 3 CBF5
C B
F
CBF 7
CBF 9
CBF 12
C B
F
C B
B
CBF 12
C B
B
ACCESS
PNL
3'x3'
2'x2'
19"x19"
19"x19"
30"x60"
2'x2'
3'x3'
15"x15" 20"x18"
3'x3'
PNL
ACCESS
DOWN
XEROX DC 6060
XEROX HL COLOR
SAFE
SHREDDER
HL SLOSLO
SLO
FIERY
MAIN PROCESSOR
M A
IN
P
R O
C E
S S
O R
FREE FLOW
FINISHING TABLE FINISHING TABLE
PERFORATOR
DRILL
CUTTER
WORK
STA.
USPS TABLE POSTAGE
P O
S T
A G
E
IN
S E
R T
E R
DM-800
D I-
D M
-8
MAIL SHELVES/
BINS
SORTING TABLE
SORTING TABLE
REFRIG
SHREDDER
C A
B
XEROX
SHRED
IT
OIL - WATER SEPARATOR TANK
18" DIA. MANHOLE & C.I. COVER-FLUSH W/SLAB
1,000 GAL. STORAGE
TANK PUMPOUT CONNECTION
DECON SHOWER
HOLDING TANK
CONTAMINATED WATER
DIVERSION VALVE PIT
DWN
RAMPRAMP
DWN
RAMP
DWN
RAMP
DWN
CENTRIFUGAL
CHILLER
ABSORPTION
CHILLER
#6
#5 #4
#7
#4
#6
OLD DENTAL AIR
(Dead Line)
.0
C O
P
IE
R
WORKSTATION
2 LIGHT X-RAY VIEW BOX
WORKSTATION
42"∅
L O
C K
E R
S
FILES
F
IL
E S
HI-FI
LAMINATOR TABLE
W/OVERHEAD SHELVES
P E
D
60x24
P E
D
F/S/L 42P
E D
F/S/L
84x24
F/S/LF/S/L
P E
D
48x24
F/S/L x3
L C
A R
T
X
C -C
A R
T
LCART
20X24
C
LOCKER
20X24
SCALE
LCART
20X24
O M
I-C E
L L
X
MED
REFRIG
27X30
C O
R K
B D
SHRED S/L
48x24
P E
D
C
LOCKER
20X24
C L
O C
K E
R
X
60x30
LCART
20X24
C
LOCKER
20X24
0x3
0x3
PED
x
F /S
/L
F
/S /L
(4
L F
(1
F D
(4
L F
(1
F D
PED
x
F /S
/L
F
/S /L
F /S
/L 3 x
PED
(4) LF
30PRINTER
F /S
/L 3
SHELVES
S H
E L
V E
S
SHELVES
SHELVES
SHELVES
3 3 3
1 1
1 1
W O
R K
S T
A T
IO
N
SHELF SIZES, EXISTING
36"x18"x86.75"
38"x18"x76.25"
36"x18"x78"
61.5"x25"x72.5"
48"x18"x86.75"
SHELVING SHELVINGSHELVINGSHELVING
S H
E L V
IN
G
SHELVING
MTL SHELF
M T
L S
H E
L F
M T
L S
H E
L F
PALLET
PALLET
3636 36
PALLET PALLET
MTL SHELF MTL SHELF
PALLET PALLET
MOTION
DETECTOR
SWITCH
DETECTOR
MOTION
6" PIPE
BOLLARD
S
S
I
IB
I
I
I
I
I
I
I
I
I
I
I
I
C
C
C
C
C
C
C
C
C
C
C
C C
C
C
C
C
C
C
C
C
C
C
C
C C
C
C
C
C
CC
EYE WASH
HC
AWAITING ASBUILTS
UNEXCAVATED
PLANTER
PARKING
PLANTER
PLANTER
PLANTER
MAIL ROOM
MAIL ROOM
ELECTRICAL
ENG
OFFICE ENG
SHOP
IM
OFFICE
OFFICE
IM
OFFICE
SOILED LINEN
TELEPONE OPERATORS
BREAK ROOM
TELEPHONE
EQUIPMENT
STORAGE
RESTROOM
TELEPHONE EQUIPMENT
PHARMACY STORAGE
ACQUISITIONS
OFFICE
PSYCH.
OBSERVATION
PSYCH. OBSV.
SPS
STORAGE
SOILED
HOLDING
TELE/DATA
DUMB
WAITER
FAMILY ROOM
WHEEL CHAIR/
STRETCHER
AMMO
STORAGE
STORAGE
ENGINEERING
SHOP
CANTEEN
STORAGE
BIO MED
OFFICE
IV
STORAGE
MEDICAL GAS
STORAGE
ER BREAKROOM
ACQUISITIONS
GENERAL
STORAGE
EMS
TRASHCART
WASH ROOM
EMS
CLEAN LINEN
EMS
STORAGE
ENG
PAINT SHOP
ENG
ELECTRICAL
SUB-STATION - 2
EMS
WAREHOUSE
MEN'S
RESTROOM
IM
STORAGE
WAREHOUSE
LOADING DOCK
NUTRITION &
FOOD SERVICE
WAREHOUSE
SPS
MEDICAL
STORAGE
AQUISITIONS
SUPPLY
RECEIVING
MECHANICAL
EQUIPMENT RM
EMS
EQUIPMENT
STORAGE
IM
MULTIPURPOSE
EMS
OFFICE
EXAM ROOM
(INFECT. ISOL.)
EMERGENCY
GENERATOR
ELEVATOR
LOBBY
ELEVATOR
ROOM
EXAM ROOM
EXAM ROOM
EXAM ROOM
EXAM ROOM
FAST TRACK
S T
O R
A G
E
EXAM ROOM
TREATMENT ROOM 1
TRAUMA ROOM
TREATMENT ROOM 2
TREATMENT ROOM 3
TREATMENT ROOM 4
TREATMENT ROOM 5
TREATMENT
ROOM
TREATMENT
ROOM
MEDS
BREAKROOM/
LOCKERS
H.A.C.
NURSE
STATION
SLEEP
ROOM MECH.
TOILET
RESTROOM/
SHOWER
STORAGE
TOILET
TOILET MALE
TOILET FEMALE
ELEC.
BIO MED
OFFICE
BIO MED
SHOP
X-RAY
MAINT
ELEC. CLO.
MECANICAL ROOM
MECANICAL ROOM
AREAWAY
BIO MED
RECEPTION
BIO MED
SHOP
OFFICE
NURSING OFFICE
EMS
SOILED
LINEN
LOGISTIC
STORAGE
PATHOLOGY
COOLER
HAZARDOUS
WASTE
STORAGE
ACQUISITIONS
OFFICEACQUISITIONS
GENERAL
STORAGE
CANTEEN
STORAGE
TELE/DATA
ENGINEERING OFFICE
ENGINEERING STORAGE
ENGINEERING STORAGE
ENGINEERING STORAGE
ENGINEERING STORAGE
UNEXCAVATED
ENG
STORAGE
EMS
WALK-IN
REFRIG. T
O
IL
E T
TELE/
DATA
ENG
MECHANICAL
CANTEEN STORAGE
FOOD SVC
STORAGE
FOOD SVC
DUMBWAITER
FOOD SVC
WALK-IN
FREEZER
FOOD SVC
WALK-IN
REFRIGERATOR
FOOD SVC
WALK-IN FREEZER
A F
G E
S T
O R
A G
E
EMS
RED BAG
FOOD SVC
WALK-IN
REFRIGERATOR
FOOD SVC
STORAGE
FOOD SVC
KITCHEN MISC.
FOOD SVC
STORAGE
FOOD SVC
WALK-IN
REFRIGERATOR
FOOD SVC
WAREHOUSE
IM
STORAGE
ENG
EQUIPMENT
STORAGE
ENG
EQUIPMENT
STORAGE
EMS
LINEN CHUTE
LOCKSMITH
E L
E C
T R
IC
C
L O
S E
T
EMS
STORAGE
ELEC.
CLOSET
EMS
WAREHOUSE
EMS
STORAGE
EMS
STORAGE
EMS
STORAGE
CLOSET
EMS
STORAGE
EMS
LAUNDRY
EMS
OFFICE
EMS
SOILED LINEN
IM
FOYER
EMS H.A.C.
EOC
STORAGE
ENG
PATHOLOGY
STORAGEOFFICE
H.A.C.
EMS
STORAGE
EMS
CLEAN
LINEN
EXAM ROOM 7
EXAM ROOM 8
EXAM ROOM
(INFECT. ISOL.)
DECONTAMINATION
TOILET
PA
TIE
N T
R
EC
EIV
IN
G
HOLDING
POLICE
POLICE
LOCKERS
INTERVIEW
(TRIAGE)
H.A.C.
X-RAY ROOM
CLEAN LINEN
MEDS
NURSE STATION
FIRE PUMPSUBSTATION #3
EXAM ROOM 6 EXAM ROOM 5
MECHANICAL
ELECRICAL
CLOSET
VENDING
ENTRANCE
T E
L E
D
A T
A
MECHANICAL ROOM
TELE/DATA
WAITING
ELEC
FEC
FEC
F E
C
MEDICAL GAS
STORAGE
AMBULANCE ENTRANCE
OFFICE
ELECTRICAL
S T
O R
A G
E S
T O
R A
G E
EXIT
EXIT
STORAGE
MAIL ROOM
D R
E S
S
IN
G R
O O
M
SMOKE SHACK SMOKE SHELTER
(OUTSIDE
SMOKING)
(INSIDE SMOKING)
EXAM
ROOM
EXAM
ROOM
MED
EOC
STORAGE
BF144e
BF111
BF146
BF147
BF148
BF144a
BF144
BF142
BF141
B F q
BF145a
BF145b
BF145c
BF145d
BF145e
BF145f
BF145g
BF145g1
BF145h
BF145iBF145j
BF145k
BF145p
BF145m
BF145o
BF145l
BE102c
BE100a
BE101
BE100
BE100b
BE100c
BE100d
BE102a
BE102b
BE102d
BE102
BF118
BF118a
BA119f
BA117
BA116
BA116a
BA127
BA118BA119
BA119b BA119c
BA121BA122
BF106 BA119g
BA125
BA126
BA128 BA130
BA130b1
BA130b
BA123
BA124
BA130a
BA114
BA115a
BA115
BA115b
BA113
BA112e
BA112
BA111
BA112a
BA112b
BA112c
BA112d
BA112e1
BA110
BA108BA109 BA106
BA107a
BA107
BA105a BA105b
BA105 BA105d
BA105c
BB133
BB134
BA104BA103
BA102
B A
B A
BA131
BB135
BB100
BB102
BB103
BB104
BB106
BB105
BB105a
BB107
B B
BB108 BB108d
BB108a BB108c
BB109
BB110
BB133
BB110a1
BB110a
BB132
BB132a
BB131
B B
B B
BB130
BB126
BB127
BB111BB112
BB115
BB114
BB116
BB117
BB118
BB119
BB120
BB121
BB122
BB121a
BC100
BC100a
BC100b
BF108 BF107
BF114
BF115
BF130
BF131
BF132
BF133
BF129
BF129a
BF128
BF125b
BF126
BF125
BF127
BF127a
BF153
BF154
BF124
BF123
BF122
BF121
BF119
BF120
BF135
BF134
BF136 BF137 BF138
BF113BF112
BF139 BF140
BF155
BF150
BF151
BF117
BF116
BF149
BF128
BF145n
BF145
BF128
BB107a
BE102e
BF153
B F a
B F b
B B a
BF144b BF144c
BF144d
UP
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:4
:4
P M
C U s e rs
\a m a s o n
\D o c u m e n ts
\E
-2
-O
K C
P a rk in g G a ra g e a m a s o n a c g -p a .c o m
.r v t
E-103
BASEMENT FLOOR FIBER ROUTING
PLAN
6 16CNJ
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
JULY 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
JKM
Scale: No Scale
BASEMENT FLOOR FIBER ROUTING PLAN
A. SEE DETAIL 3 ON DRAWING E-503 FOR FIBER
OPTIC REQUIREMENTS.
B. SUPPORT FIBER OPTIC CABLES IN THE EXISTING
CABLE TRAY. IF CABLE TRAY IS NOT PRESENT
SUPPORT CABLES ON J-HOOKS EVERY 4-5 FEET
PER BICSI.
1 EXISTING TELECOM ROOM/OIT TO REMAIN.
SEE RISER DETAIL 3 ON DWG E-503 FOR
MORE INFORMATION.
6E
E
B B
F
BBF
F
SPEC 8101MSPEC 8101MSPEC 8102M SPEC 8101MSPEC 8101MSPEC 8102M
B B
F
36F x6 x6
BBF
x6
B B
FF
F
FF
BBF
F
BBF
F
B B
F
36F x6
36F 36S
F
B B
F
BBFBBF
BBF
CHASE
OPEN TO LOWER
ROOF OF
LOWER LEVEL
LEVEL OF GD106b
UPPER LEVEL
SEATING
MEDICAL MEDIA &
AUDITORIUM
ELEVATOR
P-1
ELEVATOR
P-2
ELEVATOR
P-3
ELEVATOR
P-4
ELEVATOR
P-5
ELEVATOR
P-6
STAIR 5STAIR 2
S T
A
IR
S T
A
IR
STAIR 12
STAIR 1
STAIR 11
C G
A
VENDOR
RACK RACK
VENDOR
RACK
VENDOR
D O
W N
D O
W N
D O
W N
D O
W N
U P
U P
U P
U P
LAUNDRY ROOF
S
PED
C1
P E
D
P E
D
86x2457x24 x
60x24
P E
D
60x24
P E
D
C
PED
C x
C1 C1
C1
C1
PED
C1
C
P E
D4 x
48x24
RICOH
COPIER
x
PED
C1 x
D E
S K x
D E
S K
PED
84x24
42 42
FILE
PR F
FILE
C16 x
PED
x
PED
C1 x
PED
C1 6 x
PED
C1 x
PED
C1 x
PED
C1
24X30
X
30/60
30F
24X60
30F
F
X
F
30X42
F
X
24X60
F
X
24x60
F
F
30S 30F
30S 30F
30/60
30F
24X60
30F
30/60
30F
24X60
30F
/6
F
X
F x
B B
F
WSSP
x6
30F
60x24
30F 3 S x
F
48F
48x24BBF
F
BBF
/6
F
X
F
F
30F (2)
24X60
30S30S
24X60
30S30S
24X60
30S 30SRICOH
COPIER
EQPT
S
F
139 SF
S
F S
F
358 SF
S
F
S
F
563 SF
306 SF
490 SF
S
F
S
F
467 SF
S
F
S
F
521 SF52
SF
S
F
S
F
CGB 2
C G
B
C G
B
C G
D
1CGD 2
CGH 10-1
CGD 4
C G
H
CGH 3
C G
H
-1
C G H 8-1
C G
H
C G
H
CGD 3
C G H
C G
H 6 C G
H
C G
B
ROOF
FRESH
C H
OIC
ES
B
ISTRO
HO
T
WE
LLHO
T
WE
LLHO
T
WE
LL
HO
T /
CO
LD
HO
T /
CO
LD
HO
T
WE
LL
P A S T R Y C O F F E E
S T A N D
C O L D
B E V E R A G E S
Q U
IC
K
S T O P
D E S S E R T
IN
N
CHICKEN
EXPRESS
HOOD EQUIPMENT
FIRE SUPPRESSION HOOD
H
OT
W
EL
L
H
OT
W
EL
L
H
OT
W
EL
L
H
OT
W
EL
L
H
OT
W
EL
L
H
OT
W
EL
L
H
OT
W
EL
L
H
OT
W
EL
L
H
OT
W
EL
L
H
OT
W
EL
L
H
OT
W
EL
L
H
OT
W
EL
L
H
OT
W
EL
L
H
OT
W
EL
L
H
OT
W
EL
L
OLD DENTAL AIR
(Dead Line)
KEYBOARD
PC
BULLETIN BOARD
KEYBOARD
FUTURE
PC
M O
N
IT
O R
T V
M O
N
IT
O R
BULLETIN BOARD
EXPANSION TANK
OFFICE
PRIMARY
CARE
EYE CLINIC
SUPERVISOR
ELEC
T E
L E
D
A T
A
ELECTRICAL
BENEFICIAL TRAVEL
BLDG.
CANTEEN RETAIL
STORE
OFFICE
OXYGEN STORAGE
VTS ADMIN
WHEELCHAIR
STORAGE
ALLERGY
CLINIC STORAGE
OFFICE
OFFICE
PRIMARY
CARE
OFFICE
PRIMARY
CARE
MOBILE FILE
ROOM
NEGATIVE CHEMO
CLEAN ROOM
POSITIVE IV
CLEAN ROOM
ANTE-ROOM
POSITIVE
ANTE-ROOM
PHARMACY
STORAGE
EMS
OFFICE
LOW VISION
EXAM ROOM
TELE/DATA
C A
N T
E E
N S
T O
R A
G E
C A
N T
E E
N S
T O
R A
G E
C A
N T
E E
N S
T O
R A
G E
CANTEEN
CANTEEN KITCHEN
H.A.C.
FREEZER
FOOD STORAGE
FOOD STORAGE
DELI
OFFICE
CANTEEN SERVICE
E L
E C
H.A.C.
STORAGE
TRAY WASH
T E
L E
/D A
T A
C L O
S E
T
ELEC
ELEC
CANTEEN
DINING ROOM
MECHANICAL ROOM
TOILET
FEMALE
TOILET
MALE TRAVEL
WAITING ROOM
PATIENT TRANSPORT
MECHANICAL ROOM
E L
E C
T R
IC
C
L O
S E
T
TOILET FEMALETOILET MALE
LOWER
STORAGE
COVID SHOTS
COVID
LAB
MALE
LOCKER ROOM
FEMALE
LOCKER ROOM
STORAGE
COVID SHOTS
OBSERVATION
ALLERGY CLINIC
H.A.C.
FEC
E L E
C
T E
L E
D
A T
A
FEC
FEC
F E
C
BENE TRAVEL/
VETERAN TRANSPORT
MECHANICAL ROOM
MEDICAL MEDIA STORAGE
STORAGE STORAGE
STORAGESTORAGE
M E
C H
A N
IC
A
L R
O O
M
OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE
A B
A N
D O
N E
D D
U M
B W
A
IT
E R
S H
A F
T
OFFICE
STORAGE OFFICE
OFFICE
OFFICE
BREAK ROOM
ELEC
CLASSROOM
K
IT
C H
E N
OFFICE
OFFICE
OFFICE
OPTICAL
SHOP
SHOP/
STORAGE
SOILED
UTILITY
OFFICE
NURSING
SERVICE
EXAM ROOM
PRE-TESTING
#1
EXAM ROOM
PRE-TESTING
#2
EXAM ROOM
PRE-TESTING
#3
EXAM ROOM
PRE-TESTING
#4
EXAM ROOM
PRE-TESTING
#5
EXAM ROOM
PRE-TESTING
#6
EXAM ROOM
PRE-TESTING
#7
OFFICE
STORAGE
WAITING
BREAK AREA
OFFICE
OFFICE
WAITING
OFFICE
OFFICE
OFFICE
OFFICE
ALLERGY
CLINIC
WAITING
VOLUNTEER
STORAGE
WAITING
ALLERGY
CLINIC STORAGE
MOBILITY MANAGEMENT/
BENEFICIAL TRAVEL
SUPERVISOR
OFFICE
LEAD OFFICE
LOW VISION
TRAINING ROOM
PCPC PC
NIGHT
DROP
D
IS
P L
A Y
C A
S E
A L
A R
M S
W
IT
C H
GA154
GA153
GA152
GA151
GA108
GA115GA114GA113GA112
GA109
GA107
GA106
GA105
G A
G A
G A
GA103
G B
G B
G B
GB104b
GB104d
GB104c
GB104
GB104f11 GB106a
GB106GB106b
GB104f
G B
GB119
GB106c
G B l
GB104k
GB118a
GB117
GB108
G B
GB110
GB115
GB114
GB111
GB113GB112
GD101GD101a
G D
GD108GD107
GH100GH101
GD103
GD104
GD102
GD105
GD106b GD106b1
GD106a
GD106
G D e
GD106d
GD106c
GH104
GH105
GH119
GH117
GH118
GH106 GH107 GH108 GH110 GH111 GH114 GH115 GHH116
GH113GH112
GH109
G H a
GD106g
GD106f
GD102a GD102b
GD102
GB104j
GB104g
GA142b1 GA142a1
GA142b GA142a
GA142
GA143d
GA104
GB103
GB104e
GB104h
GB104i
GB104k1
GB109
GB116
GB118
GH103
GH102
GA143
GB121d
GB121a
GA109a
GA110 GA111
GA111a
GA116
GB121b
GB121c
GB121
GB121e
GB120b
GB120a
GB120
GB120f
GB120e
GB120d
GB120c
GD107a
GB110a
GA104a
UP/DOWN
SEE
BASEMENT
PLAN ON E-103
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:4
:4
P M
C U s e rs
\a m a s o n
\D o c u m e n ts
\E
-2
-O
K C
P a rk in g G a ra g e a m a s o n a c g -p a .c o m
.r v t
E-104
GROUND FLOOR FIBER ROUTING PLAN
7 16CNJ
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
JULY 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
JKM
Scale: No Scale
GROUND FLOOR FIBER ROUTING PLAN
A. SEE DETAIL 3 ON DRAWING E-503 FOR FIBER
OPTIC REQUIREMENTS.
B. SUPPORT FIBER OPTIC CABLES IN THE EXISTING
CABLE TRAY. IF CABLE TRAY IS NOT PRESENT
SUPPORT CABLES ON J-HOOKS EVERY 4-5 FEET
PER BICSI.
COPIER
P R
T
FAX
PRT
C O
P
IE
R
C O
P
IE
R
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
CC
C C
C
C
C
ELEVATOR
P-6
ELEVATOR
P-5
ELEVATOR
P-4
ELEVATOR
P-3
ELEVATOR
P-2
ELEVATOR
P-1
S T
A
IR
-1
ELEVATOR
P-11
CHASE
CHASE
ELEVATOR
P-8
ELEVATOR
P-7
ELEVATOR
P-10
ELEVATOR
P-9
STAIR 8
CHASE
STAIR 9
MECHANICAL
CHASE
STAIR 11
STAIR 5
STAIR 1
STAIR 12
BUILDING #19
S T
A
IR
S T
A
IR
STAIR 2
STAIR 7
CHASE
CHASE
STAIR 6
D N
U P
UNDER CONSTRUCTION
UNDER CONSTRUCTION
UNDER CONSTRUCTION
APAP
APAP
AP
D48 D47 V25
D44 D43 V23
D42
D41 V22
D40
D39 V21
D46
V24 D45
D50
D49 V26
D51 D52
V27
D54
V28 D53 D55
D56
V29
V5D14
D13 V7
D10
D9
D16
D15 V8
D11
D12
V6
D2 D1 V1
TTT TT
T
T T T T T
T
T T
T T T T T
T
T
T
T
MP
MA
MB
MG
PBK
S
F
1194 SF
S
F
619 SF
158 SF7
S
F
79 SF
S
F
154 SF
S
F S
F
117 SF
637 SF
S
F
866 SF
S
F
815 SF
954 SF
S
F
S
F
S
F
1040 SF
296 SF 890 SF
S
F S
F 586 SF
S
F
190 SF
S
F
S
F
100 SF
561 SF
383 SF
1176 SF
S
F
S
F
80 SF
86 SF
S
F
S
F
S
F
883 SF
S
F
S
F
500 SF
S
F
230 SF
C
B
-1
C G
C A
C1A 2-1 C1A 2
C A
C A
C A
C1A 6
C A
C B
C
B
C1B 3
C1B 5
C1B 6
C B
C1E 1
C1E 2
C E
C1E 4
C E
C1F 1-1
C F
-1
C F
-1
C1F 4-1
C F
-1
C F
-1
C1F 7-1
C1F 8-1
C1F 9-1
C1F 10-1
C1F 13-1
C F
-1
C1F 15-1
C1F 16-1
C F
-1
C F
-1
C1F 19-1
C F
-1
C F
-1
C F
-1
C1G 2
C1G 3
C G
C1G 5
C1G 6
C G
C1G 8
ROOF
ROOF
OLD DENTAL AIR
(Dead Line)
PUMPS
VACUUM
4"
MOTOR
PUMP
4" VENT TO 4TH
FLR ROOF
ORAL EVACUATION
ACCUMULATOR TANK
3" DRAIN
COLLIMATOR COLLIMATOR
UPS
OPEN TO DECK
OPEN TO DECK
NOTE: CEILING HEIGHT @ 108'-0"
NOTE: CEILING HEIGHT @ 108'-0"
EXISTING ELECTRICAL
FLOOR TRENCH
WD
PBS
MB
MA
MS
PBK
MW
PHY
AC
TV
MSA
SP
ME
MS
HATCHED FLOOR IS NOT
LEAD SHIELDED
LEAD SHIELDING IN
THIS AREA IS
2-LAYERS AT 1/32"
S
S
S
S
I
SP
S
UNIT
MOB.
COPIER
PROJECTOR
S C
R E
E N
T V
T V
S C
R E
E N
SCREEN
R E
F
-B
A Y
/3 -T
IE
R
S E
C U
R
IT
Y C
O N
S O
L E
SHREDDER
S H
R E
D D
E R
OVEN
VACUUM FORMER
T H
E R
M O
F O
R M
E R
C A
R V
E R
THERMO
FORMER
T O
O L B
O X
T O
O L B
O X
SAND
BLASTER SHOE
SOLER
SHOE
MACHINE
TOOL BOX
PUNCH PRESS
DRILL
PRESS
ROUTER
SANDER S
A
N D
E
R ROUTER
BAND SAW
DRILL
PRESS
PLASTER
TRAP
AWAITING ASBUILTS
AWAITING ASBUILTS
A W
A
IT
IN
G
A S
B U
IL
T
S
AWAITING ASBUILTS
AWAITING ASBUILTS
A W
A
IT
IN
G
A S
B U
IL
T
S
IMAGING
ROOM
PREP ROOM
IMAGING
ROOM
TOILET FEMALE
TOILET MALE
IMAGING
ROOM
FELLOWS
OFFICE
HEART STATION
WORKROOM
OFFICE
CARDIOLOGY
WET LAB
BREAK
ROOM
SUPPLIES
CONTROL
ROOM
IMAGING
ROOM
PHYSICIAN
READING ROOM
WAITING
AREA
RECEPTION
FILES CHIEF OFFICE
OFFICE
SUPERVISOR
OFFICE
ADMINISTRATIVE
PHYSICIST
OFFICE
COMPUTER
ROOM
IMAGING
ROOM
PATIENT
INJECTION
TOILET
ELEC
H.A.C.TELEPHONE
CLOSET
RESIDENTS
WORK
ROOM
OFFICE
TECH
SUPERVISOR
DOCTOR
OFFICE
MEDS
STAFF WORK
AREA
DOCTOR
OFFICE
NURSING
LOUNGE
OFFICE
EXAM
EXAM
TREATMENT
PLANNING /
DOSIMETRY
EXAM
EXAM
EXAM
ELECTRICAL
SUBSTATION
PATIENT
TOILET
PATIENT
TOILET
WAITING
PATIENT
DISCHARGE
LOBBY
ELECTRICAL/
MECHANICAL
CLOSET
PHYSICS
STORAGE
VESTIBULE
SOILED UTILITY
HOLD / SUB-WAIT
CLEAN UTILITY
CLEAN LINEN
L
IN
A C
C
O N
T R
O L
CT TOILET
P H
Y S
IC
IS
T W
O R
K A
R E
A
L
IN
A C
C
O N
T R
O L
HOT LAB
PDA PDA PDA
CT SIMULATOR CT
CONTROL
PET/CT
LINAC 2
LINAC 1
EXAM
EXAM
EXAM 3 EXAM 2
EXAM
HOMEOXY.
COR/
PURCHASING
OFFICE
WAITING
AREA
RECEPTION
AREA
STORAGE
SOILED
UTILITY
MECHANICAL ROOM
CHIEF
OF
SERVICE
EXAM
EXAM
PARALLEL
BARS
ELEC
H.A.C.
CLEAN
LINEN
PRACTITIONERS'
OFFICE
TOILET
MALE
KITCHENETTE
TOILET
FEMALE
THERMO PLASTIC
MOLDING & WELDING
PLASTER
MODELING
CARVER
MACHINE
ROOM
INVENTORY/
STORAGE
SEWING ROOM
LAB CHIEF
STORAGE
OFFICE
TECHNICIAN
STORAGE
ELEC
COMPUTER
ROOM
E MODULE
CHECK IN
E M
O D
U L
E W
A
IT
IN
G
R O
O M
TOILET MALE
TOILET FEMALE
PFT
MAS/
CHECK OUT
EXAM
EXAM
PROCEDURE
ROOM
TEAM
ROOM
EXAM
HAC
PATIENT RESTROOM
SOILED
LINEN
TEAM
ROOM
OFFICE
STORAGE
OFFICE
OFFICE
T E
L E
/D A
T A
E L
E C
T R
IC
A
LOFFICEOFFICEOFFICEOFFICECONFERENCE ROOMOFFICEOFFICE
H.A.C.
ELECTRIC
CLOSET
STORAGE
OFFICE
SUPERVISOR OFFICE
OFFICE
OFFICE
OFFICE
OFFICEOFFICE
OFFICE
OFFICE
OFFICE
TOILET MALE
MAS OFFICE
CHECK OUT
MAS
CHECK IN
WAITING
ROOM
MECH
EQUIPMENT
RM.
SECURITY
MONITORPROJECTOR ROOM
NEURO
TEAM
ROOM
FOYER
MED TEAM
ROOM
VESTIBULE
SUITE
CARDIAC CATH
LAB
RECOVERY/HOLDING
EQUIPMENT
CONTROL
ROOM
CARDIAC
CATH LAB
#1
CARDIAC
CATH LAB
#2
CONTROL
ROOM
SCRUB
STORAGE
CLEAN
UTILITY
EXAM
ROOM 6
ELEC
CLOSET
MED TEAM
ROOM
TREATMENT ROOM
ISOLATION
TREATMENT
ROOM
ISOLATION
TOILET
ELEC.
CLOSET
SOILED UTILITY
PHARMACIST
TOILET
MED GAS
STORAGE
CLEAN
LINEN
TRIAGE
CHECK-IN
CONSULTATION
WAITING
TOILET
NURSE
STATION
KITCHEN
TREATMENT AREA
C H
A
IR
C H
AIR
#4
C H
A
IR
C H
A
IR
C H
A
IR
C H
A
IR
CHAIR
#4
CHAIR
#3
CHAIR
#2
CHAIR
#1
NEURO CLINIC
INFUSION CLINIC
ELECTRICAL CLOSET
E Q
U
IP
VIEWING ROOM MEN WOMEN
STRESS LAB
EQUIPMENT
SPEECH
PATHOLOGY
TREATMENT
SPEECH PATHOLOGY
OFFICE
EARMOLD
LAB
OFFICE
OFFICE
PACEMAKER
EXAM
ECHO
LAB
SECRETARY
EXAM EXAM
STORAGE
EXAM
ECHO
EXAM
EXAM
ECHO
EXAM
ECHO
READING ROOM
STORAGE
SPEECH
OFFICE
COMPUTER
ROOM
SPEECH
PATHOLOGY
OFFICE
SPEACH
PATHOLOGY
LAB
SPEACH
PATHOLOGY
SECTION
CHIEF
STAFF
LOUNGE
ELECTRIC CLOSET
EXAM
E.K.G.
EXAM
E.K.G.
EXAM
E.K.G.
PFT
TOILET
FEMALE
OFFICEEXAMEXAMEXAM
OFFICEOFFICEOFFICE
EXAM
WAITING
EXAM
CHECK-IN/MAS
WAITING
AREA
ODVA
RELEASE OF
INFORMAITON
AGENT CASHIER
DECEDENT
AFFAIRS
LOST & FOUND
SYSTEMS REDESIGN
VETERANS JUSTICE OUTREACH OFFICE
VOC
REHAB
SPECIALIST
OFFICE
HOMELESS WALK-IN OFFICE
TRANSITION
CARE MNGNT
OFFICE
CAREGIVER
SUPPORT PROGRAM
OFFICE
CPAP
F E
C
FECFEC
S T
O R
A G
E
TELEPHONE
H.A.C.
CHECK IN
RECEPTION
TOILET
MALE
CLEAN
LINEN
MED ROOM
EXAM
EXAM
KITCHEN
LAB
EXAM EXAM
EXAMEXAM
EXAM EXAM
EXAMEXAM
OFFICE
OFFICE
OFFICE
S T
O R
A G
E
PROCEDURE/EXAM
ELEC
STORAGE
ELEC
ELEC
ELECTRICAL
H.A.C.
OFFICE OFFICE OFFICE
OFFICE
OFFICE
PACEMAKER
OFFICE
OFFICE
OFFICE
SOCIAL WORK
WAITING
T E
L E
E L
E C
TELE/DATA
ECHO
STORAGE
OFFICE
STORAGE
AUDIOLOGY
ADMIN
RESIDENTS
EXAM
PACEMAKER
OFFICE
EXAM
EXAM EXAM
EXAM
VASCULAR
LAB
VESTIBULE
SOILED
UTILITY
TRASH
S T
O R
A G
E
STORAGE
EXAMEXAM
EXAM EXAM
OFFICE
TEAM
ROOM EXAM
EXAM
EXAM
EXAM
EXAM
PUVA
ROOM
ELECTRICAL
TOILET
TOILET
H.A.C.
EXAM
NURSING
OFFICE
IT DATA
TOILET
HEARING
AID &
FITTING
STORAGE
VA EXPRESS
EXAM EXAM
S T
O R
A G
E
CARDIAC
CATH LAB #3
STORAGE SOILED
UTILITY
CONTROL ROOM
EQUIPMENT
BREAK
ROOM
AUD/SPEECH
PATH CHIEF
ELIGIBILITY
MY HEALTHY VET
COMMUNICATION
OFFICER
DAV
AMERICAN
LEGION
ANTI ROOM
TEAM
ROOM
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
OXYGEN
STORAGECLEAN
LINEN
CLEAN UTILITY
PUVA/EXAM
EXAM
EXAM
EXAM
PROCEDURE
ROOM
EXAM
EXAM
LAB
MED
ROOM
EXAM
ROOM 7
EXAM
ROOM 8
EXAM
ROOM 9
EXAM
ROOM 10
EXAM
ROOM 5
EXAM
ROOM 4
EXAM
ROOM 3
EXAM
ROOM 2
EXAM
ROOM 1
NUTRITION
ROOM
PATIENT SERVICE
CENTER
ELIGIBILITY
SUPERVISOR
ELIGIBILITY
OFFICE
NEURO TEAM
ROOM
NEURO
OFFICE
MED ROOM
PROCEDURE
ROOM
1F132
1F1311F130
1F144
1F145
1F140
1F141
1F142
1F136
1F135a
1F135
1F134 1F133
1F137a 1F137b
1F139
1F139a
1F137
1F137c
1F137d 1F137e
1F191b
1F191a
1F187d
1F191
1F192 1F138a
F f
1F110
1F111
1F112
1F113
1F160 1F166b
1F166a
1F160a
1F161
1F166c
1F166
1F102
F
1F100
1F11…
This is the start of the file's text. The full file is on GovTribe.