Attachment 04 Struct 100_ 19-292.pdf
PDF 15 MB Posted
- Solicitation number
- 36C77623B0046
About this file
This document provides details for a federal contract opportunity to construct a parking garage addition at a Department of Veterans Affairs medical center in Oklahoma City, Oklahoma. The solicitation number is 36C77623B0046 and seeks construction services for a minor parking garage expansion known as project Y1DA--635-414. Responses are due by the date listed on the Federal Business Opportunities website. Interested contractors should review the 15MB attachment for additional requirements and technical specifications. The award is expected to be granted in 2023 following evaluations.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D D
E E
C C
G G
B
A
1.6
8.8
F
3.9
EX 1 EX 2 EX 3 EX 4 EX 5 EX 6 EX 7 EX 8 EX 9 EX 10 EX 11 EX 12
EX A
EX B
EX C
EX D
(FV)
395' - 1"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(F V
/4
(F V
/2
(F V
/4
OUTLINE OF PV ARRAY FRAMING ABOVE
ALL EXISTING WIDE
FLANGE COLUMNS
TO BE REMOVED
B.6
4.5 5.5 6.5 7.55.2
5.2
2.2 3.1
SD202
SD202
SD201
SD201
GARAGE GRID SYSTEM
SHOWN FOR REFERENCE
(HALF-TONE)
CONCRETE DRILLED PIER
FOUNDATIONS TO BE REMOVED,
SEE DEMO ELEVATIONS FOR
MINIMUM EXTENT OF REMOVAL
AT EACH PIER, TYP
EXISTING CANOPY GRID
SYSTEM (FULL-TONE)
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg. of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
19-292
/1
/2
:4
:0
P
M C
U s e rs \r lo n y o
\D o c u m e n ts \2
.0
-2
V A
O K
C G
A R
A G
E
C E
N T
R A
L S
T R rl o n y o
S
B
V .r v t
SD101
DEMOLITION PLAN - PV ARRAY
FOUNDATION
1 47RAL
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
JULY 8, 2022
100% CONSTRUCTION DOCUMENTS
635-414
LAN
1/16" = 1'-0"SD101
1 DEMOLITION PLAN - PV ARRAY FOUNDATION
N
GENERAL PLAN NOTES:
1. REFER TO STRUCTURAL DEMOLITION GENERAL NOTES, LEGEND, SCHEDULES, AND TYPICAL DETAILS.
2. REFERENCE ALL APPLICABLE DEMOLITION DRAWINGS FOR ADDITIONAL INFORMATION.
3. EXCAVATION EXTENTS SHALL BE MINIMIZED AS PRACTICAL TO INSTALL NEW WORK.
4. ALL EXISTING CONDITIONS INCLUDING THE EXISTING FOOTINGS, ELEVATIONS AND THICKNESS ARE TO
BE VERIFIED IN THE FIELD PRIOR TO COMMENCING WORK.
5. PROTECT ALL ITEMS TO REMAIN PER DEMOLITION GENERAL NOTES.
RENOVATION (EXISTING CONDITIONS)
INFORMATION SHOWN FOR THE EXISTING STRUCTURE WAS GENERATED BASED ON
INFORMATION OBTAINED BY THE DESIGN TEAM DURING A SITE VISIT AND A SURVEY
PERFORMED BY MACARTHUR ASSOCIATED CONSULTANTS, LLC.
THE CONTRACTOR SHALL USE QUALIFIED, EXPERIENCED, PERSONNEL FOR
DEMOLITION AND REMOVAL OPERATIONS. PERFORM DEMOLITION AND REMOVAL
OPERATIONS IN A CAREFUL AND ORDERLY MANNER TO PREVENT HAZARDS TO
PERSONS, DAMAGE TO PROPERTY, AND THE SPREADING OF DUST AND DEBRIS.
PRIOR TO THE START OF WORK, THE CONTRACTOR SHALL VERIFY THAT THE SCOPE
OF DEMOLITION INDICATED ON THE CONTRACT DOCUMENTS SHALL NOT DAMAGE,
CUT, OR DISRUPT AND SERVICE OF ANY UTILITY SERVICE SERVING AN ADJACENT SITE
OR INTENDING TO BE RE-USED FOR THIS SITE
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE CONDITIONS
RELATING TO THE EXISTING STRUCTURE AND TO NOTIFY THE STRUCTURAL ENGINEER
IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS.
THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS AND METHODS OF
DEMOLITION REQUIRED TO COMPLETE THE WORK, INCLUDING MAINTAINING THE
SAFETY AND INTEGRITY OF THE EXISTING STRUCTURE. DEMOLISHED MATERIALS
SHALL BE DISPOSED OF SAFELY AND IN CONFORMANCE WITH THE CONTRACT
DOCUMENTS AND ALL APPLICABLE LAWS, CODES AND REGULATIONS.
WHERE ELEMENTS ARE INDICATED TO BE CUT AND REMOVED, ALL PORTIONS OF THE
ELEMENTS TO REMAIN SHALL BE BELOW THE DEMO ELEVATION LISTED IN THESE
DOCUMENTS. AT THE CONTRACTOR'S DISCRETION, FOUNDATION ELEMENTS MAY BE
REMOVED BEYOND THE MINIMUM EXTENT INDICATED.
EXISTING MATERIALS TO BE REMOVED AND REINSTALLED AS PART OF THIS PROJECT,
THAT BECOME DAMAGED, SHALL BE REPLACED WITH NEW MATERIAL OF EQUAL
QUALITY AND APPEARANCE, AT THE CONTRACTOR'S EXPENSE.
ALL WORK SHALL BE PERFORMED WITHOUT DAMAGE OR DISRUPTION TO ADJACENT
RETAINED WORK. ADJACENT EXISTING CONSTRUCTION SHALL BE PROTECTED FROM
DUST, DIRT AND DEBRIS ACCUMULATION AT ALL TIMES.
D
E
C
G
1.6
8.8
F
3.9
EX 1 EX 2 EX 3 EX 4 EX 5 EX 6 EX 7 EX 8 EX 9 EX 10 EX 11 EX 12
EX A
EX B
EX C
EX D
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
35' - 11"
(FV)
395' - 1"
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E) W16X36
(E) W16X36
(E) W16X36
(E) W16X36
(E) W16X36
(E) W16X36
(E) W16X36
(E) W16X36
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(E
W X
(F V
/2
(F V
/4
(F V
/2
(F V
/2
(F V
/2
(F V
/4
(F V
/2
EXISTING
STRUCTURAL
FRAMING TO BE
REMOVED, TYP
4.5 5.5 6.5 7.55.2
5.2
2.2 3.1
SD202
SD202
SD201
SD201
APPROX. OUTLINE OF PV ARRAY
GARAGE GRID SYSTEM
SHOWN FOR REFERENCE
(HALF-TONE)
DISMANTLE AND REMOVE PV
ARRAY PANELS AND RETURN
TO THE VA FOR STORAGE
AND FUTURE USE
EXISTING CANOPY GRID
SYSTEM (FULL-TONE)
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg. of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
19-292
/1
/2
:4
:0
P
M C
U s e rs \r lo n y o
\D o c u m e n ts \2
.0
-2
V A
O K
C G
A R
A G
E
C E
N T
R A
L S
T R rl o n y o
S
B
V .r v t
SD102
STEEL DEMOLITION - PV ARRAY
2 47RAL
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
JULY 8, 2022
100% CONSTRUCTION DOCUMENTS
635-414
LAN
1/16" = 1'-0"SD102
1 STEEL DEMOLITION - PV ARRAY
N
GENERAL PLAN NOTES:
1. REFER TO STRUCTURAL DEMOLITION GENERAL NOTES, LEGEND, SCHEDULES, AND TYPICAL DETAILS.
2. REFERENCE ALL APPLICABLE DEMOLITION DRAWINGS FOR ADDITIONAL INFORMATION.
3. EXCAVATION EXTENTS SHALL BE MINIMIZED AS PRACTICAL TO INSTALL NEW WORK.
4. ALL EXISTING CONDITIONS INCLUDING THE EXISTING FOOTINGS, ELEVATIONS AND THICKNESS ARE TO
BE VERIFIED IN THE FIELD PRIOR TO COMMENCING WORK.
5. PROTECT ALL ITEMS TO REMAIN PER DEMOLITION GENERAL NOTES.
LEVEL 01
1248' - 0"
(EXISTING) PV ARRAY
1264' - 6"
EX 1 EX 2 EX 3 EX 4 EX 5 EX 6 EX 7 EX 8 EX 9 EX 10 EX 11 EX 12
395' - 1"
35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11"
DEMO EL. 1238.00'
EXISTING PIER
(FULL DEMO)
EXISTING PIER
(FULL DEMO)
EXISTING PIER
(FULL DEMO)
EXISTING PIER
(FULL DEMO)
EXISTING PIER
(FULL DEMO)
DISMANTLE AND REMOVE
PV ARRAY PANELS AND
RETURN TO THE VA FOR
STORAGE AND FUTURE USE
EXISTING
GRADE, VIF
GRADE, SEE
CIVIL DRAWINGS
EXISTING
STRUCTURAL
STEEL FRAMING
EXISTING PIER,
(PARTIAL DEMO)
DEMO EL. 1239.00' DEMO EL. 1239.25' DEMO EL. 1239.50' DEMO EL. 1238.50' DEMO EL. 1239.00' DEMO EL. 1239.00'
LEVEL 01
1248' - 0"
1 2 3 4 5 6 7 8 9
(EXISTING) PV ARRAY
1264' - 6"
EX 1 EX 2 EX 3 EX 4 EX 5 EX 6 EX 7 EX 8 EX 9 EX 10 EX 11 EX 12
5.2
302' - 0"
38' - 0"36' - 0"36' - 0"36' - 0"10' - 0"36' - 0"36' - 0"36' - 0"38' - 0"
395' - 1"
35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11"
EXISTING PIER
(FULL DEMO)
EXISTING PIER
(FULL DEMO)
EXISTING
GRADE, VIF
GRADE, SEE
CIVIL DRAWINGS GRADE, SEE
CIVIL DRAWINGS
SLAB-ON-GRADE, SEE
S-SERIES DRAWINGS
FOUNDATION
STRUCTURE, SEE
S-SERIES
DRAWINGS
EXISTING
STRUCTURAL
STEEL FRAMING
EXISTING PIER,
(PARTIAL DEMO)
EXISTING PIER,
(MAY REMAIN)
EXISTING PIER,
(MAY REMAIN)
EXISTING PIER,
(MAY REMAIN)
GARAGE GRID SYSTEM
SHOWN FOR REFERENCE
(HALF-TONE)
DISMANTLE AND REMOVE
PV ARRAY PANELS AND
RETURN TO THE VA FOR
STORAGE AND FUTURE USE
DEMO EL. 1244.50' DEMO EL. 1242.75' DEMO EL. 1242.00' DEMO EL. 1242.50' DEMO EL. 1242.00'DEMO EL. 1246.00' DEMO EL. 1245.25'
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg. of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
19-292
/1
/2
:4
:0
P
M C
U s e rs \r lo n y o
\D o c u m e n ts \2
.0
-2
V A
O K
C G
A R
A G
E
C E
N T
R A
L S
T R rl o n y o
S
B
V .r v t
SD201
DEMO ELEVATIONS
3 47RAL
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
JULY 8, 2022
100% CONSTRUCTION DOCUMENTS
635-414
LAN
1 : 150SD201
1 DEMO CD - DEMO ELEVATION - EXISTING GL-A
1 : 150SD201
2 DEMO CD - DEMO ELEVATION - EXISTING GL-B
LEVEL 01
1248' - 0"
1 2 3 4 5 6 7 8 9
(EXISTING) PV ARRAY
1264' - 6"
EX 1 EX 2 EX 3 EX 4 EX 5 EX 6 EX 7 EX 8 EX 9 EX 10 EX 11 EX 12
5.2
302' - 0"
38' - 0"36' - 0"36' - 0"36' - 0"10' - 0"36' - 0"36' - 0"36' - 0"38' - 0"
395' - 1"
35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11"
EXISTING PIER
(FULL DEMO)
EXISTING GRADE, VIF
GRADE, SEE
CIVIL DRAWINGS
SLAB-ON-GRADE, SEE
S-SERIES DRAWINGS
FOUNDATION STRUCTURE,
SEE S-SERIES DRAWINGS
GRADE, SEE
CIVIL DRAWINGS
EXISTING STRUCTURAL
STEEL FRAMING
EXISTING PIER,
(PARTIAL DEMO)
GARAGE GRID SYSTEM
SHOWN FOR REFERENCE
(HALF-TONE)
DISMANTLE AND REMOVE
PV ARRAY PANELS AND
RETURN TO THE VA FOR
STORAGE AND FUTURE USE
EXISTING PIER (FULL DEMO)
DEMO EL. 1245.75'
DEMO EL. 1248.00'
DEMO EL. 1246.75'
DEMO EL. 1246.00'
DEMO EL. 1241.50' DEMO EL. 1242.50' DEMO EL. 1243.50'
DEMO EL. 1243.50' DEMO EL. 1243.25'
DEMO EL. 1243.25'
LEVEL 01
1248' - 0"
1 2 3 4 5 6 7 8 9
(EXISTING) PV ARRAY
1264' - 6"
EX 1 EX 2 EX 3 EX 4 EX 5 EX 6 EX 7 EX 8 EX 9 EX 10 EX 11 EX 12
5.2
302' - 0"
38' - 0"36' - 0"36' - 0"36' - 0"10' - 0"36' - 0"36' - 0"36' - 0"38' - 0"
395' - 1"
35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11" 35' - 11"
EXISTING PIER
(FULL DEMO)
EXISTING
GRADE, VIF
GRADE, SEE
CIVIL DRAWINGS
SLAB-ON-GRADE, SEE
S-SERIES DRAWINGS
FOUNDATION STRUCTURE,
SEE S-SERIES DRAWINGS
GRADE, SEE
CIVIL DRAWINGS
EXISTING
STRUCTURAL
STEEL FRAMING
EXISTING PIER,
(PARTIAL DEMO)
GARAGE GRID SYSTEM
SHOWN FOR REFERENCE
(HALF-TONE)
DISMANTLE AND REMOVE
PV ARRAY PANELS AND
RETURN TO THE VA FOR
STORAGE AND FUTURE USE
DEMO EL. 1246.00'
DEMO EL. 1246.50' DEMO EL. 1246.25' DEMO EL. 1246.25' DEMO EL. 1246.25' DEMO EL. 1245.75' DEMO EL. 1245.25' DEMO EL. 1245.00' DEMO EL. 1244.75' DEMO EL. 1244.25'
DEMO EL. 1244.25'
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg. of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
19-292
/1
/2
:4
:0
P
M C
U s e rs \r lo n y o
\D o c u m e n ts \2
.0
-2
V A
O K
C G
A R
A G
E
C E
N T
R A
L S
T R rl o n y o
S
B
V .r v t
SD202
DEMO ELEVATIONS
4 47RAL
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
JULY 8, 2022
100% CONSTRUCTION DOCUMENTS
635-414
LAN
1 : 150SD202
1 DEMO CD - DEMO ELEVATION - EXISTING GL-C
1 : 150SD202
2 DEMO CD - DEMO ELEVATION - EXISTING GL-D
MISCELLANEOUS SYMBOLS
NORTH ARROW
GRIDLINES
SOIL
SECTION NUMBER
SHEET NUMBER
S101
S101
CALLOUT NUMBER
SHEET NUMBER
A
ELEVATION
REFERENCE
LIMIT OF EXTENT
CONTINUOUS EXTENT
C# COLUMN NOTATION
Z# PRECAST/ BRICK SUPPORT
L# LINTEL NOTATION
F ## COLUMN FOOTING NOTATION
GB ## GRADE BEAM NOTATION
P ## PIER NOTATION
B ## CONCRETE BEAM NOTATION
PB ## POST-TENSIONED CONCRETE
BEAM NOTATION
PC ## PILE CAP NOTATION
WF ## WALL FOOTING NOTATION
SHEAR WALL NOTATIONSW ##
BW ## BEARING WALL NOTATION
GRANULAR FILL
Name
Elevation
WALL PIER NOTATIONWP ##
W ## WALL NOTATION
N
TS ## THICKENED SLAB NOTATION
# KEYED PLAN NOTE
CONCRETE SYMBOLS
POST-TENSION TENDON
ANCHOR DEAD END
LOCATION
POST-TENSION TENDON
ANCHOR JACKING
LOCATION
REBAR
CHANGE OF SLAB
ELEVATION
SLOPING SLAB
CHANGE OF SLAB
THICKNESS
MECHANICAL COUPLER
REBAR SPLICE
LIMIT OF MEMBER OR
SPAN MARK
DIRECTION OF SPAN
OPENING
SELF-EXPANDING
WATERSTOP
CONSTRUCTION JOINT
LOCATION IN CONCRETE
WALLS
REBAR TERMINATOR
INTENTIONALLY
ROUGHENED
CONSTRUCTION JOINT
TO 1/4" AMPLITUDE
WELDED WIRE
REINFORCING
PVC WATERSTOP
COLUMN CONTINUES
COLUMN TERMINATED
FORM-SAVER
SLAB ON GRADE
MARK
SOG#
WALL FOOTING OR
THICKENED SLAB
WF# / TS#
F#
ISOLATED FOOTING
CONTRACTION JOINT
LOCATION IN CONCRETE
WALLS
CONNECTORS
HEADED STUD
CONNECTOR SECTION END/ALT VIEW
CAST-IN ANCHOR
ROD
POST-INSTALLED
MECHANICAL ANCHOR
BOLT
POST INSTALLED
ADHESIVE ANCHOR
STEEL MEMBERS
W-SHAPE BEAM
SHAPE SECTION PLAN VIEWELEVATION
CHANNEL
ANGLE
DOUBLE ANGLE
HOLLOW STRUCTURAL
SECTION
-RECTANGULAR
LLV LLH
HOLLOW STRUCTURAL
SECTION
-CIRCULAR (PIPE)
OPEN WEB STEEL
JOIST
STEEL SYMBOLS
STEEL DECK
STEEL DECK MARK AND
SPAN DIRECTION
BEAM SPLICE
CONNECTION
BEAM MOMENT
CONNECTION AT COLUMN
BEAM SHEAR CONNECTION
AT COLUMN
BEAM CONTINUOUS OVER
COLUMN
SLAB ON STEEL
DECK
SLAB ON STEEL
DECK
WWR
COLUMN STARTS HERE
HANGER OR POST
HANGER OR POST
BELOW FLOOR
SLAB-ON-DECK MARK AND
SPAN DIRECTION
OR
D#
S#
C# COLUMN MARK
SIDE PLATE CONNECTION
AT COLUMN
PRECAST MEMBERS
DOUBLE TEE
SHAPE SECTION PLAN VIEWELEVATION
GIRDER
SPANDREL
PLANK
HOLLOW-CORE
MASONRY MEMBERS
CMU SECTION
CMU BOND BEAM SECTION
(FULLY GROUTED)
CMU LINTEL SECTION
(FULLY GROUTED)
SINGLE REINFORCEMENT
(FULLY GROUT REINFORCED
CELLS)
DOUBLE REINFORCEMENT
(FULLY GROUT REINFORCED
CELLS)
PLAN
PLAN
PLAN
PLAN
NON-LOAD BEARING
CMU WALL
LOAD BEARING/SHEARWALL
STEEL BEAM LEGEND (LRFD)
W18X40 C=1"
CAMBERBEAM SIZE
30K30K
BEAM REACTION,
TYP
(20)
QUANTITY OF SHEAR STUDS,
UNIFORMLY SPACED BETWEEN
SUPPORTS, UNO
"(MIN)" = STUDS @ 24" OC FOR
FULL BEAM LENGTHNOTES:
1) REACTION VALUE IS LRFD (KIPS), UNO.
2) WHERE NO VALUE IS SHOWN, DESIGN CONNECTION FOR A MINIMUM REACTION OF 24
KIPS.
3) POSITIVE CAMBER UPWARDS, NEGATIVE CAMBER DOWNWARDS. CAMBER SHOWN
ON CANTILEVERS IS AT END OF CANTILEVER.
4) BEAMS ARE PRIMARY MEMBERS FOR FIREPROOFING UNLESS NOTED AS SECONDARY.
5) "M" IN PLACE OF BEAM SIZE INDICATES W10X12.
6) LATERAL FORCE TO BE TRANSFERRED THROUGH SUPPORT BY CONNECTIONS IN
ADDITION TO VERTICAL REACTION FORCES. FORCE MAY ACT IN EITHER DIRECTION.
FORCE IS GREATER OF 1.0W OR 1.0E, UNO.
MOMENT CONNECTION
CANT BM, SAME SIZE
AND END REACTION AS
BACKSPAN, UNO
C=1/2" CAMBER
##K
NOTE 6
JST JOIST
JT JOINT
KB KNEE BRACE
KIP, K 1,000 POUNDS
KO KNOCK-OUT
KSI KIPS PER SQUARE INCH
L ANGLE OR LENGTH
LAB LABORATORY
LB POUND
LF LINEAL FOOT
LIN LINEAL, LINEAR
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONGIT LONGITUDINAL
LP LOW POINT
LSL LAMINATED STRAND LUMBER
LSLT LONG SLOTTED HOLE
LTWT LIGHT WEIGHT
LVL LAMINATED VENEER LUMBER
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MACHINE BOLT
MC MISCELLANEOUS CHANNEL
MECH MECHANICAL
MEMB MEMBRANE
MEP MECHANICAL/ ELECTRICAL/ PLUMBING
MF MOMENT FRAME
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MULT MULTIPLE
N/A NOT APPLICABLE
NO NUMBER
NOM NOMINAL
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OFD OVERFLOW DRAIN
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPPHD OPPOSITE HAND
ORIG ORIGINAL
OVS OVERSIZED HOLE
OWJ PRE-MANUFACTURED OPEN WEB JOIST
PAF POWDER ACTUATED FASTENER
PC PRECAST CONCRETE
PEMB PRE-ENGINEERED METAL BUILDING
PERIM PERIMETER
PERM PERMANENT
PERP PERPENDICULAR
PJP PARTIAL JOINT PENETRATION
PL PLATE
PLF POUNDS PER LINEAL FOOT
PLYWD PLYWOOD
PREFAB PREFABRICATED
PRELIM PRELIMINARY
PREP PREPARATION, PREPARE
PROJ PROJECTION
PS PRESTRESSED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSL PARALLEL STRAND LUMBER
PT POST-TENSIONED
R RADIUS
RD ROOF DRAIN
REF REFERENCE
REINF REINFORCEMENT, REINFORCE
REQD REQUIRED
RO ROUGH OPENING
RTU ROOFTOP MECHANICAL UNIT
S SLOPE
SCHED SCHEDULE
SECT SECTION
SF SQUARE FEET
SHT SHEET
SIM SIMILAR
SIP STRUCTURAL INSULATED PANEL
SOG SLAB-ON-GRADE
SOMD SLAB ON METAL DECK
SPA SPACES, SPACE
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
SSLT SHORT SLOTTED HOLE
STD STANDARD
STIFF STIFFENER
STL STEEL
STRUC STRUCTURAL
SYM SYMMETRICAL
T & B TOP AND BOTTOM
T/ TOP OF
T/GB TOP OF GRADE BEAM
TBS MECHANICAL TENSION BUTT SPLICE
TC TOP CHORD
TEMP TEMPERATURE
THRU THROUGH
TJI PREFABRICATED WOOD I-JOIST
TRANS TRANSVERSE
TYP TYPICAL
UL UNDERWRITERS' LABORATORY INC.
UNO UNLESS NOTED OTHERWISE
UT ULTRA-SONIC TEST
VERT VERTICAL
W WIDE FLANGE
W/ WITH
W/O WITHOUT
WD WOOD
WH WEEP HOLE
WP WORK POINT
WT WEIGHT, STRUCTURAL T
WWF, WWR WELDED WIRE REINFORCEMENT
XS EXTRA STRONG (PIPE)
XXS DOUBLE EXTRA STRONG (PIPE)
& AND
A/E ARCHITECT/ENGINEER
ACI AMERICAN CONCRETE INSTITUTE
ADDL ADDITIONAL
ADJ ADJACENT
AGGR AGGREGATE
AISC AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
ALT ALTERNATE
ANSI AMERICAN NATIONAL STANDARDS
INSTITUTE
APA AMERICAN PLYWOOD ASSOCIATION
APPROX APPROXIMATE
AR ANCHOR ROD
ARCH ARCHITECTURAL
ASTM AMERICAN SOCIETY FOR TESTING AND
MATERIALS
AWS AMERICAN WELDING SOCIETY
B/ BOTTOM OF
BAL BALANCE
BC BOTTOM CHORD
BD BOARD
BF BRACED FRAME
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BOT BOTTOM
BRG BEARING
BRKT BRACKET
BTWN BETWEEN
BU BUILT UP
C STANDARD CHANNEL
CANT CANTILEVER
CC CENTER TO CENTER
CF COLD FORMED
CG CENTER OF GRAVITY
CIP CAST-IN-PLACE
CJ CONTROL, CONTRACTION OR
CONSTRUCTION JOINT
CJP COMPLETE JOINT PENETRATION
CL CENTERLINE
CLR CLEARANCE, CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CTR CENTER
CTRD CENTERED
CU FT CUBIC FEET
CU IN CUBIC INCH
CYD CUBIC YARD
DBA DEFORMED BAR ANCHOR
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION, DEMOLISH
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIAPH DIAPHRAGM
DIM DIMENSION
DN DOWN
DO DITTO
DP DEEP
DWG DRAWING
DWL DOWELS
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL, ELEV ELEVATION
ELEC ELECTRICAL
ENCL ENCLOSURE
ENGR ENGINEER
EOD EDGE OF DECK
EOJ EDGE OF JOIST
EOS EDGE OF SLAB
EQ EQUAL
EQPT EQUIPMENT
ES EACH SIDE
EW EACH WAY
EX EXISTING
EXP EXPANSION
EXT EXTERIOR
FD FLOOR DRAIN
FDN FOUNDATION
FIN FINISH
FLG FLANGE
FLR FLOOR
FS FAR SIDE
FT FEET
FTG FOOTING
FTGD FOOTING DRAIN
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GB GRADE BEAM
GL GLUED LAMINATED TIMBER (GLULAM)
GRND GROUND
GT GIRDER TRUSS
HAS HEADED ANCHOR STUD
HORIZ HORIZONTAL
HP HIGH POINT
HSS HOLLOW STRUCTURAL SECTION
HT HIP TRUSS
HVAC HEATING, VENTILATION, AIR
CONDITIONING
ID INSIDE DIAMETER
IF INSIDE FACE
IN INCH
INCL INCLUDE
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
J/BRG JOIST BEARING
STRUCTURAL DRAWINGS ABBREVIATIONS
SHEET # SHEET NAME
SD101 DEMOLITION PLAN - PV ARRAY FOUNDATION
SD102 STEEL DEMOLITION - PV ARRAY
SD201 DEMO ELEVATIONS
SD202 DEMO ELEVATIONS
S001 ABBREVIATIONS AND SYMBOLS
S002 GENERAL NOTES
S003 GENERAL NOTES
S004 SPECIAL INSPECTION REQUIREMENTS
S005 LOAD MAPS
S006 FOUNDATION REACTION TABLE
S007 WIND LOAD ELEVATIONS
S008 AXONOMETRICS
S010 BASIS OF DESIGN - FUTURE DEMO
S011 BASIS OF DESIGN - FUTURE DEMO
S012 BASIS OF DESIGN - FUTURE DEMO AXONOMETRICS
S020 BASIS OF DESIGN - FUTURE EXPANSION
S021 BASIS OF DESIGN - FUTURE EXPANSION
S022 BASIS OF DESIGN - FUTURE EXPANSION
S023 BASIS OF DESIGN - FUTURE EXPANSION
S024 BASIS OF DESIGN - FUTURE EXPANSION
S025 BASIS OF DESIGN - FUTURE EXPANSION
S026 BASIS OF DESIGN - FUTURE AXONOMETRICS
S100 LEVEL 1 - FOUNDATION
S101 LEVEL 1 - SLAB ON GRADE
S102 LEVEL 2 - STRUCTURAL FRAMING
S103 LEVEL 3 - OVERALL ROOF FRAMING
S201 ENLARGED PLANS
S202 ENLARGED PLANS
S203 ENLARGED PLANS
S211 EXTERIOR ELEVATIONS
S212 SHEARWALL ELEVATIONS
S221 BUILDING SECTIONS
S222 BUILDING SECTIONS
S223 BUILDING SECTIONS
S301 FOUNDATION SCHEDULES, SECTIONS, AND DETAILS
S302 FOUNDATION SCHEDULES, SECTIONS, AND DETAILS
S303 FOUNDATION SECTIONS AND DETAILS
S304 FOUNDATION SECTIONS AND DETAILS
S305 FOUNDATION SECTIONS AND DETAILS
S306 FOUNDATION SECTIONS AND DETAILS
S307 FOUNDATION SECTIONS AND DETAILS
S311 PRECAST SECTIONS AND DETAILS
S312 PRECAST SECTIONS AND DETAILS
S313 PRECAST SECTIONS AND DETAILS
S314 PRECAST SECTIONS AND DETAILS
S401 CMU SCHEDULES, SECTIONS, AND DETAILS
S501 STEEL SCHEDULES AND DETAILS
STRUCTURAL INDEX
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg. of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
19-292
/1
/2
:4
:3
P
M C
U s e rs \r lo n y o
\D o c u m e n ts \2
.0
-2
V A
O K
C G
A R
A G
E
C E
N T
R A
L S
T R rl o n y o
S
B
V .r v t
S001
ABBREVIATIONS AND SYMBOLS
5 47RAL
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
JULY 8, 2022
100% CONSTRUCTION DOCUMENTS
635-414
LAN
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg. of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
19-292
/1
/2
:4
:3
P
M C
U s e rs \r lo n y o
\D o c u m e n ts \2
.0
-2
V A
O K
C G
A R
A G
E
C E
N T
R A
L S
T R rl o n y o
S
B
V .r v t
S002
GENERAL NOTES
6 47RAL
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
JULY 8, 2022
100% CONSTRUCTION DOCUMENTS
635-414
LAN
GENERAL
STRUCTURES INDICATED ON THESE DRAWINGS HAVE BEEN DESIGNED FOR THE IN-SERVICE
LOADS ONLY. THE METHODS, MEANS, PROCEDURES, AND SEQUENCES OF CONSTRUCTION ARE
THE RESPONSIBILITY OF THE CONTRACTOR. THE STRUCTURES ARE DESIGNED TO BE SELF-
SUPPORTING AND STABLE AFTER CONSTRUCTION IS COMPLETE. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO DETERMINE CONSTRUCTION PROCEDURES AND SEQUENCE TO ENSURE
SAFETY OF THE STRUCTURES AND RELATED COMPONENTS DURING CONSTRUCTION. THIS
INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS,
TIEDOWNS, ETC.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT CONSTRUCTION LOADS DO NOT
EXCEED THE CAPACITY OF ANY STRUCTURAL ELEMENT AT THE TIME THE LOADS ARE APPLIED,
INCLUDING BUT NOT LIMITED TO: WEIGHTS OF MATERIALS, WEIGHTS OF EQUIPMENT AND
WORKERS, AND ALL LOADS APPLIED FROM TEMPORARY LIFTS, HOISTS AND CRANES, ETC.
THE STRUCTURAL DRAWINGS AND SPECIFICATIONS SHALL BE USED IN CONJUNCTION WITH THE
DRAWINGS AND SPECIFICATIONS OF ALL OTHER DISCIPLINES, TRADES, AND DELEGATED
DESIGN ELEMENTS. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF THE
STRUCTURAL WORK WITH ALL OTHER APPLICABLE TRADES.
THE GENERAL NOTES ON THE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE FULL
WRITTEN MATERIAL SPECIFICATIONS (IF ANY) FOR THE PROJECT.
DO NOT SCALE THE DRAWINGS. REFER TO THE WRITTEN DIMENSIONS AND INFORMATION.
IF A DISCREPANCY IS NOTED ON THE DRAWINGS, GENERAL NOTES, OR SPECIFICATIONS, THE
CONTRACTOR SHALL SUBMIT TO THE STRUCTURAL ENGINEER A WRITTEN REQUEST FOR
CLARIFICATION AND SHALL NOT PROCEED WITH THE AFFECTED WORK WITHOUT DOCUMENTED
RESOLUTION OF THE DISCREPANCY. ALL COSTS RESULTING FROM THE CONTRACTOR
IMPROPERLY PROCEEDING WITH THE AFFECTED WORK PRIOR TO DOCUMENTED RESOLUTION
OF THE DISCREPANCY, INCLUDING COST OF REMOVAL AND REPLACEMENT OF NON-
CONFORMING WORK, SHALL BE BORNE BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE
OWNER.
CONCRETE MIX DESIGN SUBMITTAL
THE CONTRACTOR SHALL SUBMIT FOR THE REVIEW OF THE STRUCTURAL ENGINEER A MIX
DESIGN FOR EACH PROPOSED CLASS OF CONCRETE. EACH MIX DESIGN SHALL BE IDENTIFIED
BY A MIX NUMBER OR OTHER UNIQUE IDENTIFICATION. THE CONTRACTOR SHALL NOT VARY
FROM THE MIX DESIGNS NOR USE ANY CONCRETE OTHER THAN THE APPROVED MIX DESIGNS
WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER. MIX DESIGN SUBMITTALS SHALL
INCLUDE THE FOLLOWING INFORMATION:
1. MIX DESIGN NUMBER OR UNIQUE IDENTIFICATION AND INTENDED LOCATION OF
PLACEMENT.
2. CEMENT TYPE, PROPORTION AND NAME OF MANUFACTURER.
3. FLY ASH PROPORTION (WHEN USED), LABORATORY ANALYSIS CERTIFICATION, AND
NAME AND LOCATION OF SUPPLIER.
4. COURSE AGGREGATE PROPORTION, GRADATION REPORT, NAME AND LOCATION OF
SUPPLIER.
5. FINE AGGREGATE PROPORTION, GRADATION REPORT, NAME AND LOCATION OF
SUPPLIER.
6. MIXING WATER PROPORTION AND SOURCE.
7. ADMIXTURE DOSAGES, PRODUCT NAME(S) AND MANUFACTURER NAME(S).
8. FIBER REINFORCEMENT DOSAGE (WHEN USED), PRODUCT NAME AND MANUFACTURER
NAME.
9. DESIGN 28-DAY COMPRESSIVE STRENGTH (F'C).
10. DESIGN SLUMP RANGE.
11. DESIGN AIR-ENTRAINMENT (FOR CONCRETE REQUIRING ENTRAINED AIR).
12. STATISTICAL ANALYSIS OF LABORATORY STRENGTH TEST DATA IN ACCORDANCE WITH
"STANDARD DEVIATION" DETERMINATION OUTLINED IN ACI 318.
PRODUCT DATA SUBMITTALS
THE CONTRACTOR SHALL SUBMIT FOR APPROVAL PRODUCT DATA FOR THE SPECIFIC ITEMS
LISTED BELOW. CONTRACTOR SHALL NOT USE PRODUCTS OTHER THAN THOSE SUBMITTED
WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER.
SUBMIT HARD COPIES OR ELECTRONIC VERSIONS OF PRODUCT DATA. FOR HARD COPY
OPTION, SUBMIT A MINIMUM OF TWO COPIES OF PRODUCT DATA TO THE STRUCTURAL
ENGINEER FOR REVIEW (ONE COPY SHALL BE RETAINED BY THE STRUCTURAL ENGINEER). FOR
ELECTRONIC OPTION, SUBMIT PRODUCT DATA IN ADOBE PDF FORMAT.
1. CONCRETE CURING COMPOUND
2. CONCRETE JOINT SEALANT
3. WATER STOPS
4. MASONRY JOINT REINFORCEMENT
5. ADHESIVE ANCHORS
6. NON-SHRINK GROUT
7. PENETRATING SEALANTS
8. EXPANSION JOINTS
9. PRE-COMPRESSED EXPANDING SEALANTS
FOUNDATIONS
SEE GEOTECHNICAL REPORT NUMBER 03215009 PREPARED BY TERRACON CONSULTANTS INC.
DATED 03/29/2022 AND ALL APPLICABLE ADDENDA AND AMENDMENTS FOR INFORMATION
RELATED TO FOUNDATION EXCAVATIONS AND SOIL-RELATED WORK.
FOUNDATION DESIGN PARAMETERS:
DEEP FOUNDATIONS (DRILLED CAISSONS):
NET ALLOWABLE BEARING: 50,000 PSF
(SEE CAISSON ELEVATION SCHEDULE FOR MINIMUM EMBEDMENT DEPTH INTO
WEATHERED SHALE OR SANDSTONE)
MAX. ALLOWABLE SKIN FRICTION
INTO HIGHLY WEATHERED STRATUM: 1,000 PSF
INTO WEATHERED STRATUM: 2,500 PSF
ALLOWABLE PASSIVE PRESSURE
WITHIN OVERBUREN SOILS: 1,500 PSF
WITHIN HIGHLY WEATHERED STRATUM: 8,000 PSF
WITHIN WEATHERED STRATUM: 30,000
MINIMUM CAISSON DIAMETER: 24 INCHES
MINIMUM DEPTH TO BOTTOM OF FOUNDATION: 30 INCHES (FROST DEPTH)
MINIMUM VOID SPACE BENEATH GRADE BEAMS: 4 INCHES
MAXIMUM VERTICAL CAISSON SETTLEMENT: 1/2 INCH
MAXIMUM DIFFERENTIAL CAISSON SETTLEMENT: <1/2 INCH
MAXIMUM LATERAL CAISSONS DEFLECTION: <1/4 INCH
SLABS-ON-GRADE:
MODULUS OF SUBGRADE REACTION:
SOIL SUBGRADE: 100 PSI/IN
4" TYPE "A" AGGREGATE OVER SOIL SUBGRADE: 110 PSI/IN
RETAINING WALLS:
ACTIVE PRESSURE, Ka (DRAINED)
GRANULAR: 40 PCF
LEAN CLAY: 50 PCF
AT-REST PRESSURE, Ko (DRAINED)
GRANULAR: 55 PCF
LEAN CLAY: 70 PCF
PASSIVE PRESSURE, Kp (DRAINED)
GRANULAR: 360 PCF
LEAN CLAY: 288 PCF
SOIL DENSITY: 120 PCF
MINIMUM BACKFILL COMPACTION: ≥95% STANDARD PROCTOR
FOUNDATIONS AND SOILS RELATED WORK SHALL BE INSPECTED BY A LICENSED
GEOTECHNICAL ENGINEER. WRITTEN FIELD REPORTS SHALL BE FORWARDED TO THE
STRUCTURAL ENGINEER AS SOON AS THEY BECOME AVAILABLE.
FOUNDATION CONDITIONS NOTED DURING CONSTRUCTION, WHICH DIFFER FROM THOSE
DESCRIBED IN THE GEOTECHNICAL REPORT, SHALL BE REPORTED TO THE STRUCTURAL
ENGINEER AND GEOTECHNICAL ENGINEER BEFORE FURTHER CONSTRUCTION IS ATTEMPTED.
THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE AND MAINTAIN APPROPRIATE
EXCAVATION PROTECTION, INCLUDING ALL NECESSARY LAYBACKS, SHORING, SHEETING, TIE-
BACKS AND OTHER MEASURES AS DETERMINED BY THE CONTRACTOR'S ENGINEER.
EXCAVATIONS FOR SPREAD FOOTINGS, COMBINED FOOTINGS, CONTINUOUS FOOTINGS AND
MAT FOUNDATIONS SHALL BE CLEANED AND HAND TAMPED TO UNIFORM SURFACE AND SHALL
BE PROTECTED AND MAINTAINED UNIFORM UNTIL CONCRETE IS PLACED.
BELOW-GRADE WALLS
DO NOT BACKFILL AGAINST BELOW-GRADE CONCRETE (OR MASONRY) WALLS UNTIL THE
CONCRETE (OR MASONRY ASSEMBLAGE) HAS REACHED ITS 28-DAY COMPRESSIVE STRENGTH.
WHERE BACKFILL IS REQUIRED ON BOTH SIDES OF BELOW-GRADE WALLS, BACKFILL EVENLY
ON EACH SIDE OF EACH WALL TO PREVENT UNBALANCED SOIL LOADS AGAINST THE WALL.
CONCRETE
REINFORCED CONCRETE HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318) AND COMMENTARY (ACI 318R).
MIXING, TRANSPORTING, AND PLACING OF CONCRETE SHALL CONFORM TO THE LATEST
EDITION OF THE SPECIFICATIONS FOR STRUCTURAL CONCRETE (ACI 301). READY-MIXED
CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ASTM C94. IN CASE OF A
DISCREPANCY, THE PLANS AND SPECIFICATIONS SHALL GOVERN.
CEMENT SHALL CONFORM TO ASTM C150, TYPE I, UNO.
FLY ASH SHALL CONFORM TO ASTM C618, CLASS C OR F.
NORMAL WEIGHT AGGREGATES SHALL CONFORM TO ASTM C33.
WATER-REDUCING ADMIXTURES SHALL CONFORM TO ASTM C494.
AIR-ENTRAINING ADMIXTURES SHALL CONFORM TO ASTM C260 AND SHALL BE CERTIFIED BY
THE MANUFACTURER TO BE COMPATIBLE WITH OTHER ADMIXTURES.
CALCIUM CHLORIDE ADMIXTURES OR ADMIXTURES CONTAINING MORE THAN 0.1 PERCENT
CHLORIDE IONS SHALL NOT BE USED.
IN COLD WEATHER CONDITIONS, MIXING, PLACING, FINISHING, CURING AND PROTECTION OF
CONCRETE SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF ACI 306R,
COLD WEATHER CONCRETING.
IN HOT WEATHER CONDITIONS, MIXING, PLACING, FINISHING, CURING AND PROTECTION OF
CONCRETE SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF ACI 305R,
HOT WEATHER CONCRETING.
USE OF JOINTS IN CONCRETE ELEMENTS AT LOCATIONS OTHER THAN THOSE INDICATED ON
THE DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW.
SLUMP FOR PUMPED CONCRETE SHALL BE MEASURED AT POINT OF DISCHARGE.
NORMAL WEIGHT CONCRETE SHALL HAVE THE PROPERTIES AS INDICATED IN THE CONCRETE
MIX SCHEDULE AND SPECIFICATIONS.
DO NOT INSTALL OR EMBED ALUMINUM ITEMS, INCLUDING BUT NOT LIMITED TO ALUMINUM
CONDUIT, INTO OR IN CONTACT WITH CONCRETE.
WHERE NEW CONCRETE IS PLACED AGAINST HARDENED/EXISTING CONCRETE, VERIFY
SOUNDNESS OF EXISTING CONCRETE AND REMOVE ALL LOOSE MATERIAL, SNOW, ICE, FROST,
WATER, SOIL, DEBRIS AND OTHER DETRIMENTAL MATERIALS PRIOR TO PLACEMENT OF NEW
CONCRETE.
WELDED WIRE REINFORCEMENT
WELDED WIRE REINFORCEMENT SHALL BE SMOOTH WIRE FABRIC CONFORMING TO ASTM
A1064. REINFORCEMENT SHALL BE SUPPLIED IN FLAT SHEETS AND LAPPED A MINIMUM OF ONE
SPACE PLUS 2 INCHES.
WELDED WIRE REINFORCEMENT SHALL BE PLACED AS FOLLOWS, UNLESS NOTED OTHERWISE:
SLABS ON GRADE: 2" DOWN FROM TOP OF SLAB
SUPPORT REINFORCEMENT ON NON-METALLIC CHAIRS TO MAINTAIN PROPER POSITION
THROUGHOUT CONCRETE PLACEMENT.
(NOTE: THE TERM "WELDED WIRE FABRIC," IF USED, IS THE SAME AS "WELDED WIRE
REINFORCEMENT.")
CONCRETE TESTING
MAKE ONE SET OF TEST CYLINDERS IN ACCORDANCE WITH ASTM C31 FOR EACH DAY'S POUR
AND FOR EACH 100 CUBIC YARDS FOR EACH TYPE OF CONCRETE PLACED. EACH SET SHALL
INCLUDE ONE SPECIMEN TESTED AT 7 DAYS, 2 SPECIMENS TESTED AT 28 DAYS (3 SPECIMENS TESTED AT 28 DAYS IF USING 4x8 CYLINDERS) AND ONE SPECIMEN RETAINED IN RESERVE TO BE
TESTED AT THE DIRECTION OF THE STRUCTURAL ENGINEER. SPARE CYLINDER MAY BE
DISCARDED 90 DAYS AFTER CASTING UNLESS DIRECTED OTHERWISE BY THE STRUCTURAL
ENGINEER. THIS SET OF TEST CYLINDERS SHALL BE PROTECTED AGAINST FREEZING.
WHEN THE AMBIENT TEMPERATURE IS EXPECTED TO FALL BELOW 40 DEGREES DURING THE
COURSE OF A CONCRETE POUR OR SUBSEQUENT CURING PROCESS, AN ADDITIONAL SET OF
CONCRETE TEST CYLINDERS SHALL BE MADE AND TESTED. THESE CYLINDERS SHALL BE
STORED IMMEDIATELY ADJACENT TO, AND CURED UNDER THE SAME CONDITIONS AS THE
BUILDING CONCRETE. SPECIAL CURING BOXES ARE NOT PERMITTED FOR THESE TEST
CYLINDERS.
FORWARD COPIES OF TEST RESULTS TO THE ARCHITECT, STRUCTURAL ENGINEER, READY-MIX
SUPPLIER AND CONTRACTOR WITHIN 24 HOURS AFTER TESTING.
POTENTIALLY LOW-STRENGTH CONCRETE: WHEN 7-DAY TESTS RESULT IN CONCRETE
STRENGTHS LESS THAN 70% OF THE SPECIFIED 28-DAY STRENGTH, THE CONCRETE
CONTRACTOR SHALL INVESTIGATE TO DETERMINE THE VALIDITY AND LIKELY CAUSE(S) OF THE
LOW STRENGTH TEST RESULTS AND SUBMIT TO THE STRUCTURAL ENGINEER FOR REVIEW.
CONCRETE WHICH EXHIBITS STRENGTH BASED ON 7-DAY TESTS BELOW 70% OF THE SPECIFIED
28-DAY COMPRESSIVE STRENGTH MAY BE CONSIDERED DEFECTIVE WORK AND SHALL BE
SUBJECT TO REPAIR OR REPLACEMENT BY THE CONTRACTOR AT THE DISCRETION OF THE
OWNER AND STRUCTURAL ENGINEER AT NO ADDITIONAL COST TO THE OWNER.
REINFORCING STEEL
REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615 AND SHALL
HAVE A MINIMUM YIELD STRENGTH OF 60,000 PSI, UNO.
REINFORCING BAR DETAILING, FABRICATING, AND PLACING SHALL CONFORM TO THE LATEST
EDITION OF THE FOLLOWING STANDARDS: ACI 301, ACI 315, ACI 318, ACI DETAILING MANUAL
(SP66), AND CRSI MANUAL OF STANDARD PRACTICE.
THE CONTRACTOR SHALL PROVIDE BAR SUPPORTS AND SPACERS AS REQUIRED TO MAINTAIN
PROPER SUPPORT AND POSITIONING OF THE REINFORCING STEEL THROUGHOUT CONCRETE
PLACEMENT OPERATIONS. DESIGN OF THE SUPPORT SYSTEM SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR.
UNLESS A GREATER AMOUNT OF COVER IS INDICATED ON THE DRAWINGS, PROVIDE THE
FOLLOWING MINIMUM CONCRETE COVER OVER REINFORCEMENT AS FOLLOWS:
CONCRETE CAST AGAINST EARTH: 3 INCHES
FOUNDATION TOP REINFORCEMENT: 2 INCHES
FOUNDATION BOTTOM AND SIDE REINFORCEMENT: 3 INCHES
WALL REINFORCEMENT - #5 AND SMALLER: 1-1/2 INCHES
WALL REINFORCEMENT - #6 AND LARGER: 2 INCHES
ELEVATED SLAB TOP REINFORCEMENT: 2 INCHES
ELEVATED SLAB BOTTOM REINFORCEMENT: 1 INCH
BEAM TOP REINFORCEMENT: 2-1/2 INCHES
BEAM BOTTOM REINFORCEMENT: 2 INCHES
BEAM STIRRUPS AT TOP: 2 INCHES
COLUMN LONGITUDINAL REINFORCEMENT: 2 INCHES
COLUMN TIES: 1-1/2 INCHES
REINFORCING STEEL SHALL NOT BE TACK WELDED, WELDED, HEATED OR CUT UNLESS
INDICATED ON THE CONTRACT DOCUMENTS OR APPROVED BY THE STRUCTURAL ENGINEER.
LAP SPLICES SHALL BE TENSION LAPS IN ACCORDANCE WITH SPLICE/EMBEDMENT TABLES,
UNO.
ALL 90 DEGREE AND 180 DEGREE BENDS SHOWN ON THE DRAWINGS SHALL BE STANDARD
HOOKS, UNLESS NOTED OTHERWISE.
PROVIDE CORNER BARS OF SAME SIZE AND SPACING AS HORIZONTAL BARS AT CORNERS OF
ALL WALLS AND GRADE BEAMS. LAP SPLICE CORNERS BARS WITH STRAIGHT BARS.
UNLESS OTHERWISE SHOWN OR NOTED, PROVIDE 2-#5 BARS (ONE EACH FACE) AROUND
UNFRAMED OPENINGS IN CONCRETE WALLS AND GRADE BEAMS. PLACE BARS PARALLEL TO
THE SIDES OF THE OPENING AND EXTEND 24" BEYOND CORNERS.
PENETRATIONS AND EMBEDDED ITEMS
CONTRACTOR SHALL COORDINATE WITH ALL AFFECTED TRADES THE REQUIRED SIZES, TYPES,
AND LOCATIONS OF ALL EMBEDDED ITEMS IN, AND ALL PENETRATIONS THROUGH, STRUCTURAL
ELEMENTS PRIOR TO CONSTRUCTION.
NO PENETRATIONS THROUGH STRUCTURAL ELEMENTS, OTHER THAN THOSE SHOWN ON THE
STRUCTURAL DRAWINGS, SHALL BE MADE WITHOUT THE APPROVAL OF THE STRUCTURAL
ENGINEER.
NO ITEMS (INCLUDING, BUT NOT LIMITED TO, CONDUIT, PIPING, ETC.), OTHER THAN THOSE
SHOWN ON THE STRUCTURAL DRAWINGS, SHALL BE EMBEDDED IN STRUCTURAL ELEMENTS
WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER.
ALL EMBEDDED ITEMS IN EXPOSED EXTERIOR CONCRETE SHALL BE GALVANIZED, PLASTIC, OR
EPOXY-COATED.
DELEGATED DESIGN
FOR ALL SUBMITTALS INDICATED AS "DELEGATED DESIGN," THE CONTRACTOR SHALL ENGAGE
A SPECIALTY STRUCTURAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS
LOCATED TO DESIGN AND DETAIL THE ITEMS NOTED IN THE STRUCTURAL SUBMITTALS AND
SPECIFICATIONS AS A DELEGATED DESIGN.
DELEGATED DESIGN CALCULATIONS AND RELATED DRAWINGS SHALL CONTAIN THE
FOLLOWING, AS A MINIMUM:
1. COVER PAGE SIGNED AND SEALED BY THE SPECIALTY STRUCTURAL ENGINEER
INCLUDING A STATEMENT OF CERTIFICATION THAT THE SUBMITTED CALCULATIONS ARE
IN CONFORMANCE WITH THE DESIGN CRITERIA PROVIDED IN THE CONTRACT
DOCUMENTS AND THAT THE RELATED SHOP DRAWINGS ARE IN CONFORMANCE WITH
THE SUBMITTED CALCULATIONS.
2. TABLE OF CONTENTS, PLACED ON, OR IMMEDIATELY FOLLOWING THE COVER SHEET.
3. SUMMARY OF APPLICABLE CODE CRITERIA, LOAD DATA AND PERFORMANCE CRITERIA
AS OUTLINED IN THE CONTRACT DOCUMENTS.
4. CLEAR DEFINITION OF THE LOCATION(S) IN THE STRUCTURE WHERE EACH
CALCULATION APPLIES.
5. LOCATION, TYPE, MAGNITUDE AND DIRECTION OF ALL LOADS IMPOSED ON THE
STRUCTURE BY THE DELEGATED DESIGN SYSTEM/COMPONENTS.
SUBMITTALS THAT DO NOT CONTAIN THE INFORMATION NOTED ABOVE MAY, AT THE
STRUCTURAL ENGINEER'S DISCRETION, BE REJECTED WITHOUT COMMENT.
THE STRUCTURAL ENGINEER’S REVIEW OF DELEGATED DESIGN SUBMITTALS WILL BE FOR
GENERAL CONFORMANCE WITH THE DESIGN LOADING, DESIGN INTENT AND LOADS IMPOSED.
DELEGATED DESIGN CALCULATIONS SHALL BE SUBMITTED PRIOR TO, OR INCLUDED WITH, THE
ASSOCIATED SHOP DRAWING SUBMITTAL. DELEGATED DESIGN SHOP DRAWINGS SUBMITTED
WITHOUT APPLICABLE REQUIRED CALCULATIONS WILL BE REJECTED.
SHOP DRAWING SUBMITTALS
THE CONTRACTOR SHALL PREPARE DETAILED SHOP DRAWINGS TO ENABLE ALL PARTS OF THE
WORK TO BE FABRICATED AND CONSTRUCTED IN ACCORDANCE WITH THE DRAWINGS AND
SPECIFICATIONS. THESE SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE
WITH THE DESIGN INTENT ONLY. THE CONTRACTOR IS RESPONSIBLE FOR ALL DIMENSIONS,
ACCURACY AND FIT OF WORK.
ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO THE
STRUCTURAL ENGINEER. DRAWINGS SUBMITTED WITHOUT CONTRACTOR'S REVIEW WILL BE
RETURNED UNCHECKED.
PROVIDE ALL SUBMITTALS IN ELECTRONIC PDF FORMAT.
WORK REQUIRING SUBMITTALS FOR STRUCTURAL ENGINEER REVIEW SHALL NOT BE STARTED
BY THE CONTRACTOR WITHOUT APPROPRIATE REVIEWED SUBMITTALS. WORK PERFORMED BY
THE CONTRACTOR PRIOR TO RECEIVING APPROPRIATE REVIEWED SUBMITTALS SHALL BE
SUBJECT TO REMOVAL AND REPLACEMENT AS DEEMED NECESSARY BY THE STRUCTURAL
ENGINEER, AT THE CONTRACTOR'S EXPENSE, AND WITH NO COST TO THE OWNER.
SUBMIT SHOP DRAWINGS FOR EACH OF THE FOLLOWING ITEMS:
1. CONCRETE REINFORCEMENT
2. CONCRETE MASONRY REINFORCEMENT (INCLUDING PLANS AND ELEVATIONS FOR EACH
WALL INDICATING ALL CMU REINFORCING REQUIREMENTS, INCLUDING SHEAR WALLS)
3. STRUCTURAL STEEL
SUBMIT DELEGATED DESIGN SHOP DRAWINGS FOR EACH OF THE FOLLOWING ITEMS:
1. STRUCTURAL STEEL CONNECTIONS (INCLUDING DESIGN CALCULATIONS AND SUMMARY
PAGE FOR CONNECTIONS NOT SPECIFICALLY DETAILED IN THE CONTRACT DRAWINGS)
2. ARCHITECTURAL PRECAST CONCRETE COMPONENTS (INCLUDING DESIGN
CALCULATIONS, MEMBER LAYOUTS, MEMBER SIZES, MATERIALS AND CONNECTION
DETAILS) INCLUDING BUT NOT LIMITED TO:
a. PRECAST LINTELS
b. NON-LOAD BEARING SPANDREL PANELS
c. ORNAMENTAL PRECAST COMPONENTS CONNECTED TO OR SUPPORTED BY
STRUCTURAL FRAMING
3. STRUCTURAL PRECAST CONCRETE (INCLUDING DESIGN CALCULATIONS, FRAMING
LAYOUTS, MEMBER SIZES, MATERIALS AND CONNECTION DETAILS INCLUDING BUT NOT
LIMITED TO (SEE ALSO SPECS):
a. HOLLOW CORE PRECAST PLANKS
b. LOAD BEARING PRECAST WALL PANELS
c. PRECAST COLUMNS, BEAMS AND SPANDRELS
d. PRECAST DOUBLE-TEES
e. PRECAST STAIRS
4. GLAZING SYSTEMS - CURTAIN WALL AND STOREFRONT (INCLUDING DESIGN
CALCULATIONS AND CONNECTION DETAILS)
OMISSION OF ANY MATERIALS REQUIRED BY THE CONTRACT DOCUMENTS FROM SHOP
DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY FOR FURNISHING
THESE MATERIALS REGARDLESS OF WHETHER THE SUBMITTALS HAVE BEEN REVIEWED.
THE USE OF ELECTRONIC FILES OR REPRODUCTIONS OF THE CONTRACT DOCUMENTS BY THE
CONTRACTOR SIGNIFIES CONTRACTOR’S ACCEPTANCE OF ALL THE INFORMATION SHOWN “AS
IS”. CONTRACTOR WILL BE RESPONSIBLE FOR VERIFYING THE ACCURACY AND COMPLETENESS
OF THE INFORMATION PROVIDED. ISSUED DRAWINGS AND SPECIFICATIONS TAKE PRECEDENCE
OVER ANY ELECTRONIC INFORMATION PROVIDED. ADDENDA, CHANGE ORDERS,
SUPPLEMENTAL INSTRUCTIONS ARE NOT NECESSARILY INCLUDED IN THE ELECTRONIC FILES.
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN ALL CONTRACT DOCUMENTS,
INCLUDING LATEST ADDENDA, AND TO DISTRIBUTE TO ALL SUBCONTRACTORS PRIOR TO THE
SUBMITTAL OF SHOP DRAWINGS.
FLOWABLE FILL
WHERE INDICATED ON THE STRUCTURAL DRAWINGS, FLOWABLE FILL SHALL BE A
CONTROLLED LOW-STRENGTH MATERIAL (CLSM) PRODUCED AND PLACED IN ACCORDANCE
WITH RECOMMENDATIONS OF ACI 229. PROVIDE MATERIAL WITH 28-DAY COMPRESSIVE
STRENGTH OF 1,000 PSI UNLESS NOTED OTHERWISE.
"LOADS IMPOSED" SUBMITTALS
FOR EACH OF THE SYSTEMS INDICATED BELOW THAT REQUIRE "LOADS IMPOSED" SUBMITTALS,
THE CONTRACTOR SHALL PROVIDE A COMPLETE LOADING INFORMATION SUBMITTAL
IDENTIFYING THE LOCATION, MAGNITUDE, DIRECTION AND TYPE (DEAD, LIVE, WIND, SEISMIC, ETC.) OF ALL SERVICE LEVEL LOADS APPLIED TO THE STRUCTURE. THE SUBMITTAL SHALL BE
SIGNED AND SEALED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE THE
PROJECT IS CONSTRUCTED.
LOADING INFORMATION SHALL BE PROVIDED IN GRAPHIC FORM, UTILIZING MARKUPS OF
FRAMING PLANS, BUILDING ELEVATIONS OR OTHER DRAWINGS AS APPROPRIATE TO READILY
CONVEY THE LOCATIONS OF THE APPLIED LOADS. IN ADDITION, EACH LOADING LOCATION
SHALL CONTAIN A DETAIL REFERENCE SHOWING THE CONNECTION DETAIL(S) DISPLAYING
PRECISELY HOW EACH LOAD IS APPLIED TO THE STRUCTURE.
LOADS IMPOSED ON THE STRUCTURE SHALL IMPART ONLY VERTICAL AND HORIZONTAL LOADS
ON THE STRUCTURE WITHOUT INDUCING TORSIONAL LOADS ON THE SUPPORTING
STRUCTURAL ELEMENTS, UNLESS SPECIFICALLY INDICATED OTHERWISE.
THE CONTRACTOR'S PROFESSIONAL ENGINEER SHALL REVIEW THE IMPOSED LOADS TO
CONFIRM THAT THE LOADS APPLIED BY THE SYSTEM DO NOT EXCEED THE BASIS OF DESIGN
LOAD LIMITS AS INDICATED ON THE STRUCTURAL DRAWINGS.
WHERE THE LOADS IMPOSED BY THE CONTRACTOR'S PROPOSED SYSTEM EXCEED THE BASIS
OF DESIGN LOADS INDICATED ON THE STRUCTURAL DRAWINGS, THE CONTRACTOR SHALL
NOTIFY THE STRUCTURAL ENGINEER IMMEDIATELY TO DETERMINE WHETHER MODIFICATIONS
ARE NECESSARY.
SUBMIT "LOADS IMPOSED" SUBMITTALS FOR THE FOLLOWING ITEMS:
1. ARCHITECTURAL PRECAST CONCRETE
2. ELEVATOR REACTIONS
3. EXTERIOR CLADDING (CURTAIN WALL AND STOREFRONT)
CONCRETE SLABS ON GRADE
SLABS ON GRADE SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE
GUIDE FOR CONCRETE FLOOR AND SLAB CONSTRUCTION (ACI 302.1R).
PLACE CONCRETE IN A MANNER SO AS TO PREVENT SEGREGATION OF THE MIX. DELAY
FLOATING AND TROWELING OPERATIONS UNTIL THE CONCRETE HAS LOST SURFACE WATER
SHEEN OR ALL FREE WATER. DO NOT SPRINKLE FREE CEMENT ON THE SLAB SURFACE.
PROVIDE CURING OF CONCRETE SLABS ON GRADE AS REQUIRED TO ACCOMMODATE FLOOR
FINISHES AND FINISH MATERIALS PER THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS.
REVIEW ALL FLOOR FINISH REQUIREMENTS PRIOR TO PLACEMENT OF CONCRETE SLABS AND
COORDINATE SLAB MIX, PLACEMENT AND CURING TO COMPLY WITH FINISH FLOORING MATERIAL
MANUFACTURER’S REQUIREMENTS.
CURING PROCEDURES SHALL COMPLY WITH ACI 302.1R AND USE OF CURING MATERIALS SHALL
BE APPLIED IN STRICT ACCORDANCE WITH MANUFACTURER’S REQUIREMENTS. MOISTURE
RETENTION COVERS, IF USED, SHALL BE APPLIED FLAT AND SMOOTH TO RESULT IN A UNIFORM
APPEARANCE AND MINIMIZE SURFACE MARKINGS AND BLEMISHES.
UNLESS NOTED OTHERWISE, OR UNLESS MORE STRINGENT REQUIREMENTS APPLY, CURE AND
FINISH SLABS ON GRADE IN ACCORDANCE WITH THE CONCRETE SPECIFICATIONS.
CONCRETE FINISH PER CONCRETE SPECIFICATIONS, SEE ALSO ARCHITECTURAL DRAWINGS FOR
ANY AREAS REQUIRING DIFFERENT FINISH THAN NOTED IN SPECIFICATIONS.
CONTRACTOR SHALL REVIEW ALL REQUIRED FLOOR FINISH MATERIAL REQUIREMENTS PRIOR TO
PLACEMENT OF CONCRETE AND SHALL PROVIDE FLOOR SLAB FLATNESS AND LEVELNESS
MEETING THE FINISH MATERIAL SUPPLIER’S WRITTEN REQUIREMENTS. FF AND FL SHALL BE THE
MORE STRINGENT OF THE FINISH MATERIAL REQUIREMENTS AND THE FOLLOWING:
ALL STAIR AND ELEVATOR LOBBIES, UNO.
OVERALL VALUES: FF=25 FL=20
LOCAL VALUES: FF=17 FL=15* (LOCAL FL ONLY VALID IF TESTED WHILE SHORED)
ALL PARKING AND RAMP AREAS (PER ACI 302.1)
OVERALL VALUES: FF=20 FL=15
LOCAL VALUES: FF=15 FL=10* (LOCAL FL ONLY VALID IF TESTED WHILE SHORED)
SEE CONCRETE SPECIFICATIONS FOR FF AND FL REQUIREMENTS FOR CONDITIONS OTHER THAN
THAT NOTED ABOVE.
CONTRACTOR SHALL PROVIDE ALL NECESSARY REPAIR, GRINDING AND/OR LEVELING OF THE
CONCRETE SLAB TO ACCOMMODATE ALL FLOOR FINISHES PRIOR TO INSTALLATION OF THE
FINISH MATERIALS WITH NO ADDITIONAL COST TO THE PROJECT.
THE MINIMUM LOCAL AREA SHALL BE ANY BAY DEFINED BY COLUMN LINES.
UNLESS SHOWN OR NOTED OTHERWISE, PROVIDE CONTROL OR CONSTRUCTION JOINTS IN
SLABS-ON-GRADE AT A MAXIMUM SPACING NOT EXCEEDING 14.5 FEET. PROVIDE JOINTS AT ALL
COLUMN LOCATIONS. LOCATE JOINTS TO ELIMINATE RE-ENTRANT CORNERS AND TO CREATE
SQUARE OR RECTANGULAR SECTIONS WITH MAXIMUM LONG TO SHORT SIDE RATIO OF 1.5 TO 1.
CONTROL JOINTS IN SLABS ON GRADE SHALL NOT RECEIVE JOINT FILLER MATERIAL.
FINISHED SUBGRADE, WITHIN AND FOR AT LEAST 10 FT BEYOND THE FLOOR SLAB, SHOULD BE
PROTECTED FROM TRAFFIC, RUTTING, OR OTHER DISTURBANCE AND BE MAINTAINED IN
RELATIVELY MOIST CONDITION UNTIL FLOOR SLABS ARE CONSTRUCTED, SEE ALSO
CONSTRUCTION CONSIDERATIONS LISTED IN GEOTECHNICAL REPORT.
THE GEOTECHNICAL ENGINEER SHOULD APPROVE THE CONDITION OF THE FLOOR SLAB
SUBGRADES IMMEDIATELY PRIOR TO PLACEMENT OF THE FLOOR SLAB SUPPORT COURSE,
REINFORCING STEEL, AND CONCRETE.
CONCRETE UNIT MASONRY
CONCRETE MASONRY CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CODE-
REFERENCED EDITION OF BUILDING CODE REQUIREMENTS AND SPECIFICATIONS FOR
MASONRY STRUCTURES (TMS 402/602).
CONCRETE MASONRY SHALL CONSIST OF HOLLOW UNITS CONFORMING TO THE
REQUIREMENTS OF ASTM C90, WITH A MINIMUM NET AREA COMPRESSIVE STRENGTH OF 2,800
PSI, UNO. CONCRETE MASONRY ASSEMBLAGES SHALL HAVE A MINIMUM COMPRESSIVE
STRENGTH (F'M) OF 2,000 PSI AT 28 DAYS, UNO.
ALL MASONRY TO BE LAID IN RUNNING BOND, UNO. ALIGN CELLS TO ALLOW PROPER
REINFORCEMENT PLACEMENT AND GROUTING.
MORTAR SHALL BE TYPE S PROPORTIONED IN ACCORDANCE WITH ASTM C270.
FULLY MORTAR FACE SHELLS ON HEAD AND BED JOINTS. PROVIDE FULL MORTAR COVER ON
ALL WEBS AT GROUTED CELLS.
GROUT FOR REINFORCED MASONRY SHALL BE PROPORTIONED IN ACCORDANCE WITH ASTM
C476 (MINIMUM 28-DAY COMPRESSIVE STRENGTH = 2,000 PSI, UNO). COARSE AND FINE
AGGREGATES SHALL CONFORM TO ASTM C404. USE COARSE GROUT FOR ALL GROUTING
EXCEPT HIGH-LIFT POURS DEFINED BY ACI 530, WHERE FINE GROUT SHALL BE USED.
GROUT SOLID ALL CELLS WITH REINFORCEMENT.
GROUT SOLID ALL CELLS AT BELOW-GRADE CMU IN CONTACT WITH SOIL.
PROVIDE 9-GAUGE GALVANIZED STEEL WIRE JOINT REINFORCEMENT IN ALL MASONRY
CONSTRUCTION. REINFORCEMENT SHALL BE CONTINUOUS AND BE LAPPED EIGHT INCHES AT
SPLICES. CUT REINFORCEMENT AT ALL CONTROL AND EXPANSION JOINTS. SPACE
REINFORCEMENT AT 8" ON CENTER FOR PARAPETS AND BELOW GROUND FLOOR ELEVATION.
ELSEWHERE SPACE REINFORCEMENT AT 16 INCHES ON CENTER, UNLESS NOTED OTHERWISE.
BEAMS AND LINTELS SHALL BEAR A MINIMUM OF 8 INCHES ONTO SUPPORTING MASONRY,
UNLESS NOTED OTHERWISE. BEARING FOR ALL BEAMS, LINTELS, JOISTS, ETC. SHALL BE
GROUTED SOLID A MINIMUM OF ONE COURSE (8 INCHES) BELOW BEARING ELEVATION, UNLESS
NOTED OTHERWISE.
PROVIDE MASONRY CONTROL JOINTS AT 25'-0" OC MAXIMUM, UNO. LOCATE JOINTS IN
ACCORDANCE WITH NCMA TEK 10-2C "CONTROL JOINTS FOR CONCRETE MASONRY WALLS -
EMPIRICAL METHOD" AT OFFSETS, SETBACKS, WALL INTERSECTIONS, CORNERS, CHANGES IN
THICKNESS, CHANGES IN HEIGHT, OR EDGE OF OPENINGS.
MASTIC COATING
MASTIC COATING FOR PROTECTION OF INDICATED ITEMS SHALL BE BITUMASTIC 50 COAL TAR
MASTIC BY CARBOLINE OR EQUIVALENT SUBSTITUTE APPROVED BY THE STRUCTURAL
ENGINEER. INSTALL AT LOCATIONS INDICATED ON DRAWINGS.
UNLESS NOTED OTHERWISE, APPLY MASTIC TO A COATING THICKNESS OF 18 MILS. PROVIDE
FULL COVERAGE OVER ITEMS INDICATED TO RECEIVE COATING.
APPLY MASTIC COATING TO ALL STEEL ITEMS THAT WILL BE IN PERMANENT CONTACT WITH
SOIL OR FILL MATERIALS IN THE COMPLETED CONSTRUCTION.
ADHESIVE ANCHORS FOR SOLID SUBSTRATES (THREADED ROD AND REBAR)
ADHESIVE ANCHORS FOR SOLID SUBSTRATES SHALL BE HILTI "HIT-HY 200" OR AN EQUIVALENT
SUBSTITUTE APPROVED BY THE STRUCTURAL ENGINEER, UNO.
THREADED ANCHORS SHALL BE ASTM A36 RODS FOR INTERIOR EXPOSURES AND AISI 316
STAINLESS STEEL FOR EXTERIOR AND BELOW GRADE EXPOSURES, UNO.
ANCHORS SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S
REQUIREMENTS BY INSTALLERS TRAINED BY THE MANUFACTURER'S REPRESENTATIVE.
ADHESIVE ANCHORS SHALL NOT BE INSTALLED IN CONCRETE OR MASONRY UNTIL IT HAS
ATTAINED ITS SPECIFIED MINIMUM 28 DAY COMPRESSIVE STRENGTH. ADDITIONALLY,
ADHESIVE ANCHORS SHALL NOT BE INSTALLED IN CONCRETE OR MASONRY WITH AN AGE OF
LESS THAN 21 DAYS.
MINIMUM EMBEDMENT DEPTH SHALL BE 8 DIAMETERS UNLESS NOTED OTHERWISE.
NON-SHRINK GROUT
GROUT SHALL BE A NON-METALLIC, SHRINKAGE RESISTANT (WHEN TESTED IN ACCORDANCE
WITH THE LATEST EDITION OF ASTM C827 OR CRD-C621), PREMIXED, NON-CORROSIVE, NON-
STAINING PRODUCT CONTAINING PORTLAND CEMENT, SILICA SANDS, SHRINKAGE
COMPENSATING AGENTS AND FLUIDITY IMPROVING COMPOUNDS. GROUT SHALL HAVE A
MINIMUM COMPRESSIVE STRENGTH (F'C) OF 5,000 PSI IN 28 DAYS.
ADHESIVE ANCHORS FOR HOLLOW SUBSTRATES
ADHESIVE ANCHORS FOR HOLLOW SUBSTRATES SHALL BE HILTI "HIT-HY 270" WITH HILTI “HIT-
SC” SCREEN TUBE OR AN EQUIVALENT SUBSTITUTE APPROVED BY THE STRUCTURAL
ENGINEER, UNO.
ANCHORS SHALL BE ASTM A36 THREADED RODS FOR INTERIOR EXPOSURES AND AISI 316
STAINLESS STEEL FOR EXTERIOR AND BELOW GRADE EXPOSURES, UNO.
ANCHORS SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S
REQUIREMENTS BY INSTALLERS TRAINED BY THE MANUFACTURER'S REPRESENTATIVE.
EXPOSED STRUCTURAL STEEL (CANOPY POSTS AND EXPOSED FRAMING)
VISUALLY EXPOSED CANOPY STEEL SHALL BE FABRICATED AND ASSEMBLED IN THE SHOP TO
THE GREATEST EXTENT POSSIBLE. LOCATE FIELD JOINTS IN ASSEMBLIES AT CONCEALED
LOCATIONS OR AS APPROVED BY THE ARCHITECT. DETAIL ASSEMBLIES TO MINIMIZE FIELD
HANDLING AND EXPEDITE ERECTION.
VISUALLY EXPOSED CANOPY STEEL SHALL MEET AESS 1 STANDARDS AS OUTLINED BY AISC.
SEPARATION OF DISSIMILAR METALS
DISSIMILAR METALS INCLUDING STRUCTURAL SHAPES, PLATES, CONNECTORS, ETC. SHALL BE
ELECTRICALLY ISOLATED TO PREVENT GALVANIC CORROSION VIA NON-CONDUCTIVE
WASHERS, SHOULDER WASHERS, GASKETS, COATINGS, OR EQUIVALENT SUBSTITUTE
APPROVED BY THE STRUCTURAL ENGINEER, UNO.
ELEVATORS
CONTRACTOR SHALL COORDINATE ELEVATOR PITS, SHAFTS, SLAB OPENINGS, WALL
OPENINGS, INCLUDING ANY TEMPORARY OPENINGS NECESSARY FOR ELEVATOR
INSTALLATION, FRAMING LOCATIONS, GUIDE RAIL SUPPORTS, DIVIDER BEAMS, HOIST BEAMS
AND SUMP PITS WITH ELEVATOR SUPPLIER AND ALL OTHER AFFECTED TRADES PRIOR TO
CONSTRUCTION AS REQUIRED FOR PROPER INSTALLATION AND OPERATION.
COORDINATE ANY REQUIRED STRUCTURAL MODIFICATIONS WITH THE STRUCTURAL ENGINEER
PRIOR TO FABRICATION AND/OR INSTALLATION OF ANY STRUCTURAL ELEMENTS.
STRUCTURAL STEEL
STRUCTURAL STEEL MEMBERS, BRACING, COMPONENTS AND CONNECTIONS SHALL BE IN
ACCORDANCE WITH AISC LOAD AND RESISTANCE FACTOR DESIGN (LRFD) UNLESS NOTED
OTHERWISE.
STRUCTURAL STEEL DETAILING, FABRICATION AND ERECTION SHALL CONFORM TO THE
ANSI/AISC 360 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, LATEST EDITION WITH
AMENDMENTS, AND THE AISC 303 CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND
BRIDGES, LATEST EDITION WITH AMENDMENTS.
STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992.
STRUCTURAL STEEL PLATES AND ROLLED SHAPES OTHER THAN WIDE-FLANGE SHAPES SHALL
CONFORM TO ASTM A36, UNLESS NOTED OTHERWISE.
HOLLOW STRUCTURAL STEEL SECTIONS (SQUARE, RECTANGULAR, AND ROUND TUBES) SHALL
CONFORM TO ASTM A500 GRADE C, UNLESS NOTED OTHERWISE.
STRUCTURAL PIPE SHALL CONFORM TO ASTM A53, GRADE B.
STRUCTURAL STEEL ROD HANGERS AND BRACING SHALL CONFORM TO ASTM A36, UNLESS
NOTED OTHERWISE.
ANCHOR RODS SHALL CONFORM TO ASTM F1554, GRADE 36, UNLESS NOTED OTHERWISE.
FABRICATE AND ERECT STEEL FRAMING SO THAT CAMBER IS UPWARD AFTER INSTALLATION.
SPLICE MEMBERS ONLY AT LOCATIONS SPECIFICALLY INDICATED ON
THE DRAWINGS.
DO NOT FIELD MODIFY STRUCTURAL STEEL WITHOUT PRIOR WRITTEN APPROVAL OF THE
STRUCTURAL ENGINEER.
AT STRUCTURAL STEEL AND STEEL JOIST FRAMED ROOFS PROVIDE L4X4X1/4 FRAMED
OPENINGS FOR ALL ROOF PENETRATIONS 12 INCHES OR LARGER ALONG ANY SIDE, UNLESS
LARGER FRAMING IS INDICATED. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR
PENETRATIONS. COORDINATE…