Attachment 01 Gen 100_ 19-292.pdf

PDF 2 MB Posted

Attached to
Y1DA--635-414 Parking Garage 2 Construction Minor - OKC (VA-23-00002215)
Solicitation number
36C77623B0046
Issued by

About this file

This solicitation is for construction services for a parking garage at the Oklahoma City VA Medical Center. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The solicitation seeks a contractor to provide minor construction services for Parking Garage 2 including demolition of existing structures, site work, and construction of a new parking garage. The period of performance is 270 calendar days from NTP. The anticipated award date is August 2022. Pricing will be fixed price. The solicitation is unrestricted and available to all responsible sources.

View the file

Other files

File Type Posted
2nd Visit Signed Sign in Sheet OKC Parking Garage 2.pdf PDF
36C77623B0046 0007.docx DOCX document
36C77623B0046 0006.docx DOCX document
36C77623B0046 0005.docx DOCX document
36C77623B0046 0004.docx DOCX document
Tech Questions Responses OKC Parking Garage Tracking Q _ A.pdf PDF
36C77623B0046 0003.docx DOCX document
36C77623B0046 0002.docx DOCX document
OKC DBA Wages Determination OKC County.pdf PDF
amendment Site visit Sheet 36C77623B0046 0001.pdf PDF
Site Visit signed Sign in Sheet OKC Parking Garage 2.pdf PDF
Signed Site visit Sheet 36C77623B0046 0001.pdf PDF
Attachment 13 - Contractor Safety - Environmental Form.docx DOCX document
Attachment 04 Struct 100_ 19-292.pdf PDF
Attachment 08 Plumb 100_ 19-292.pdf PDF
Attachment 11 Specs.pdf PDF
Attachment 07 FS 100_ 19-292.pdf PDF
Attachment 02 Civil 100_ 19-292.pdf PDF
Attachment 09 Mech 100_ 19-292.pdf PDF
Attachment 03 Land 100_ 19-292.pdf PDF
Attachment 06 Arch 100_ 19-292.pdf PDF
Attachment 15- Site Visit Instructions.docx DOCX document
36C77623B0046_1.docx DOCX document
Attachment 14 - Limitations on Subcontracting - Construction.docx DOCX document
Attachment 10 Elec 100_ 19-292.pdf PDF
Attachment 16- DBA Wages Determination.pdf PDF
Attachment 12 - Geotech Report.pdf PDF
Attachment 05 AP AW 100_ 19-292.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

PROJECT SITE MAP PROJECT LOCATION MAP

PROJECT IMAGE OF EXISTING VAMC PARKING GARAGE

/1

/2

:1

:0

P

M C

U s e rs

\g g o n z a le s \D o c u m e n ts \A

-2

-O

K C

P a rk in g G a ra g e g g o n z a le s B

W J C

U .r v t

G-001

COVER

1 4AT

PARKING GARAGE 2

921 NE 13TH STREET

OKLAHOMA CITY, OK 73104

July 8, 2022

100% CONSTRUCTION DOCUMENTS

635-41419-292

N/A

PARKING GARAGE 2

921 NE 13TH STREET

OKLAHOMA CITY, OK 73104

VA PROJECT #: 635-414

TM

DRAWING LIST

ARCHITECTURAL PARKING

AP101 LEVEL 1 PLAN - ARCHITECTURAL PARKING 1 8

AP102 LEVEL 2 PLAN - ARCHITECTURAL PARKING 2 8

AP401 ENLARGED PLANS 3 8

AP501 STRIPING DETAILS - ARCHITECTURAL PARKING 4 8

AP502 SIGN GRAPHICS - ARCHITECTURAL PARKING 5 8

AP503 SIGN GRAPHICS - ARCHITECTURAL 6 8

AP504 SIGN GRAPHICS - ARCHITECTURAL 7 8

AP521 SIGN MOUNTING DETAILS - ARCHITECTURAL PARKING 8 8

ARCHITECTURAL WATERPROOFING

AW101 LEVEL 1 PLAN - ARCHITECTURAL WATERPROOFING 1 3

AW102 LEVEL 2 PLAN - ARCHITECTURAL WATERPROOFING 2 3

AW541 WATERPROOFING DETAILS - STRUCTURAL 3 3

ARCHITECTURAL

AG001 ARCHITECTURAL SYMBOLS, ABBREVIATIONS AND NOTES 1 20

AD100 ARCHITECTURAL SITE PLAN - DEMOLITION 2 20

AE100 ARCHITECTURAL SITE PLAN 3 20

AE101 LEVEL 1 - FLOOR PLAN 4 20

AE102 LEVEL 2 - FLOOR PLAN 5 20

AE103 ROOF PLAN 6 20

AE111 LEVEL 1 - REFLECTED CEILING PLAN 7 20

AE112 ENLARGED SECOND FLOOR REFLECTED CEILING PLANS 8 20

AE201 EXTERIOR ELEVATIONS 9 20

AE202 EXTERIOR ELEVATIONS 10 20

AE301 SECTIONS 11 20

AE302 SECTIONS 12 20

AE303 WALL SECTIONS 13 20

AE304 WALL SECTIONS 14 20

AE401 ENLARGED PLANS AND SECTIONS 15 20

AE402 ENLARGED PLANS 16 20

AE501 DETAILS 17 20

AE601 DOOR SCHEDULE, ELEVATIONS AND DETAILS 18 20

AE701 ENLARGED PLANS, SECTION - SW STAIR AND ELEVATOR BANK 19 20

AE702 VERTICAL CIRCULATION PLANS, SECTIONS AND DETAILS 20 20

FIRE SUPPRESSION

FX001 FIRE SUPPRESSION GENERAL INFORMATION 1 3

FX101 LEVEL 1 FIRE SUPPRESSION PLAN 2 3

FX401 LEVEL 1 FIRE SUPPRESSION ENLARGED PLANS 3 3

PLUMBING

P-001 PLUMBING GENERAL INFORMATION 1 5

PP101 LEVEL 1 PLUMBING PLAN 2 5

PP102 LEVEL 2 PLUMBING PLAN 3 5

P-501 ROOF PLUMBING PLANS AND PLUMBING DETAILS 4 5

P-901 PLUMBING RISERS 5 5

MECHANICAL

M-001 MECHANICAL GENERAL INFORMATION 1 5

MS101 MECHANICAL SITE PLAN 2 5

MH401 ENLARGED MECHANICAL PLANS 3 5

M-501 MECHANICAL DETAILS 4 5

M-601 MECHANICAL SCHEDULES AND DETAILS 5 5

ELECTRICAL

E-001 ELECTRICAL GENERAL NOTES, SYMBOL LEGENDS, AND ABBREVIATIONS 1 16

ES101 ELECTRICAL SITE PLAN 2 16

ES102 OVERALL ELECTRICAL CAMPUS PLAN 3 16

E-101 LEVEL 1 ELECTRICAL PLAN 4 16

E-102 LEVEL 2 ELECTRICAL PLAN 5 16

E-103 BASEMENT FLOOR FIBER ROUTING PLAN 6 16

E-104 GROUND FLOOR FIBER ROUTING PLAN 7 16

E-105 FIRST FLOOR FIBER ROUTING PLAN 8 16

E-106 NINTH FLOOR FIBER ROUTING PLAN 9 16

E-401 ELECTRICAL ENLARGEMENTS 10 16

E-402 ELECTRICAL ENLARGEMENTS 11 16

E-501 ELECTRICAL DETAILS 12 16

E-502 ELECTRICAL DETAILS 13 16

E-503 ELECTRICAL DETAILS 14 16

E-601 SINGLE LINE DIAGRAM AND ELECTRICAL SCHEDULES 15 16

E-602 ELECTRICAL SCHEDULES 16 16

DRAWING LIST

GENERAL

G-001 COVER 1 4

G-002 GENERAL INFORMATION 2 4

LS101 LEVEL 1 - LIFE SAFETY PLAN 3 4

LS102 LEVEL 2 - LIFE SAFETY PLAN 4 4

CIVIL

C002 GENERAL NOTES 1 32

VF100 OVERALL EXISTING TOPOGRAPHY PLAN 2 32

VF101 EXISTING TOPOGRAPHY PLAN 3 32

VF102 EXISTING TOPOGRAPHY PLAN 4 32

CD101 DEMOLITION PLAN 5 32

CD102 DEMOLITION PLAN 6 32

CS100 OVERALL SITE PLAN 7 32

CS101 SITE PLAN 8 32

CS102 SITE PLAN 9 32

CS200 PHASING PLAN 10 32

CG101 GRADING PLAN 11 32

CG102 GRADING PLAN 12 32

CG103 GRADING PLAN ENLARGEMENTS 13 32

CU101 UTILITY PLAN 14 32

CU102 UTILITY PLAN 15 32

CU201 STORM SEWER PLAN AND PROFILE 16 32

CU202 STORM SEWER PLAN AND PROFILE 17 32

CU203 STORM SEWER PLAN AND PROFILE 18 32

CU204 SANITARY SEWER PLAN AND PROFILE 19 32

CU205 WATER MAIN CONNECTION PLAN AND PROFILE 20 32

CE101 EROSION CONTROL PLAN 21 32

CE102 EROSION CONTROL PLAN 22 32

CE501 EROSION CONTROL DETAILS 23 32

CE502 EROSION CONTROL DETAILS 24 32

CS501 SITE DETAILS 25 32

CS502 SITE DETAILS 26 32

CS503 SITE DETAILS 27 32

CS504 SITE DETAILS 28 32

CS505 SITE DETAILS 29 32

CS506 SITE DETAILS 30 32

CS507 SITE DETAILS 31 32

CS508 SITE DETAILS 32 32

LANDSCAPE

LD-100 TREE DISPOSITION PLAN 1 3

LP-100 LANDSCAPE PLAN 2 3

LP-500 LANDSCAPE DETAILS 3 3

STRUCTURAL

SD101 DEMOLITION PLAN - PV ARRAY FOUNDATION 1 47

SD102 STEEL DEMOLITION - PV ARRAY 2 47

SD201 DEMO ELEVATIONS 3 47

SD202 DEMO ELEVATIONS 4 47

S001 ABBREVIATIONS AND SYMBOLS 5 47

S002 GENERAL NOTES 6 47

S003 GENERAL NOTES 7 47

S004 SPECIAL INSPECTION REQUIREMENTS 8 47

S005 LOAD MAPS 9 47

S006 FOUNDATION REACTION TABLE 10 47

S007 WIND LOAD ELEVATIONS 11 47

S008 AXONOMETRICS 12 47

S010 BASIS OF DESIGN - FUTURE DEMO 13 47

S011 BASIS OF DESIGN - FUTURE DEMO 14 47

S012 BASIS OF DESIGN - FUTURE DEMO AXONOMETRICS 15 47

S020 BASIS OF DESIGN - FUTURE EXPANSION 16 47

S021 BASIS OF DESIGN - FUTURE EXPANSION 17 47

S022 BASIS OF DESIGN - FUTURE EXPANSION 18 47

S023 BASIS OF DESIGN - FUTURE EXPANSION 19 47

S024 BASIS OF DESIGN - FUTURE EXPANSION 20 47

S025 BASIS OF DESIGN - FUTURE EXPANSION 21 47

S026 BASIS OF DESIGN - FUTURE AXONOMETRICS 22 47

S100 LEVEL 1 - FOUNDATION 23 47

S101 LEVEL 1 - SLAB ON GRADE 24 47

S102 LEVEL 2 - STRUCTURAL FRAIMING 25 47

S103 LEVEL 3 - OVERALL ROOF FRAMING 26 47

S201 ENLARGED PLANS 27 47

S202 ENLARGED PLANS 28 47

S203 ENLARGED PLANS 29 47

S211 EXTERIOR ELEVATIONS 30 47

S212 SHEARWALL ELEVATIONS 31 47

S221 BUILDING SECTIONS 32 47

S222 BUILDING SECTIONS 33 47

S223 BUILDING SECTIONS 34 47

S301 FOUNDATION SCHEDULES, SECTIONS, AND DETAILS 35 47

S302 FOUNDATION SCHEDULES, SECTIONS, AND DETAILS 36 47

S303 FOUNDATION SECTIONS, AND DETAILS 37 47

S304 FOUNDATION SECTIONS, AND DETAILS 38 47

S305 FOUNDATION SECTIONS, AND DETAILS 39 47

S306 FOUNDATION SECTIONS, AND DETAILS 40 47

S307 FOUNDATION SECTIONS, AND DETAILS 41 47

S311 PRECAST SECTIONS AND DETAILS 42 47

S312 PRECAST SECTIONS AND DETAILS 43 47

S313 PRECAST SECTIONS AND DETAILS 44 47

S314 PRECAST SECTIONS AND DETAILS 45 47

S401 CMU SCHEDULES AND DETAILS 46 47

S501 STEEL SCHEDULES AND DETAILS 47 47

PROJECT LOCATION PROJECT LOCATION

N N

DocuSign Envelope ID: B1166ACB-C743-4AF3-A46A-6D7C174A0143

7/18/2022

WALL SECTION

SYMBOL

INTERIOR ELEVATION

SYMBOL

COLUMN GRID

ELEVATION SYMBOL

REVISION NOTE

ENLARGED DETAIL CALLOUT

ROOM DESIGNATION

SYMBOL

BREAK LINE

ROOF SLOPE

DIRECTION SYMBOL

TYPICAL GRAPHIC SCALE

DETAIL #

PAGE #

DETAIL #

PAGE #

VIEW NORTH ARROW

A8.1

EXTERIOR ELEVATION

SYMBOL

DETAIL #

PAGE #

A8.1

A8.1

A8.1

BUILDING SECTION

SYMBOL

DETAIL #

PAGE #

A8.1

A8.1

DETAIL SECTION

SYMBOL

DETAIL #

PAGE #

A8.1

WALL GRID

(REPRESENTS

FACE OF EXISTING

WALL)

XX.X

XX.X

ELEVATION

0'-0"

ROOM

NAME

101A

NORTHNORTH

0 4 8 16

• REMOVAL OF SUICIDE PREVENTION SCREENS

• REMOVAL OF HOSE BIBBS FROM PARKING GARAGE.

• REMOVAL OF COVERED WALKWAY ON WEST SIDE OF PARKING GARAGE, LEAVE STRUCTURAL EMBEDS IN PLACE FOR

FUTURE INSTALLATION.

• ASPHALT PAVING IN SURFACE PARKING AREA NORTH OF THE NEW PARKING GARAGE AND REPLACE WITH GRAVEL; CURBS

AND GUTTER TO REMAIN IN BID.

GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS SPECIFY OTHER CODES AND

STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:

• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).

• INTERNATIONAL BUILDING CODE (IBC) 2021 (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES

BELOW)

• NFPA 101 LIFE SAFETY CODE 2021 (SEE NOTES BELOW)

• NFPA NATIONAL FIRE CODES WITH THE EXCEPTION OF NFPA 5000 AND NFPA 900

• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.

• VA SEISMIC DESIGN REQUIREMENTS, H-18-8

• NATIONAL ELECTRICAL CODE (NEC)

• SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.

• ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS) INCLUDING VA SUPPLEMENT, BARRIER FREE DESIGN

STANDARD (PG-18-13)

• BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318)

• THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 01010 OF THE

VA MASTER CONSTRUCTION SPECIFICATION.

• VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1- 2019.

• SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15 – 2019.

LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION

FEES.

NOTES:

1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN. DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/1

/2

:1

:0

P

M C

U s e rs

\g g o n z a le s \D o c u m e n ts \A

-2

-O

K C

P a rk in g G a ra g e g g o n z a le s B

W J C

U .r v t

G-002

GENERAL INFORMATION

2 4AT

PARKING GARAGE 2

921 NE 13TH STREET

OKLAHOMA CITY, OK 73104

July 8, 2022

100% CONSTRUCTION DOCUMENTS

635-41419-292

N/A

TM

GENERAL SYMBOL LEGEND

DEDUCTIVE ALTERNATE NOTES - IN ORDER OF REMOVAL

CODE STANDARDS AND EXECUTIVE ORDERS

UP

DN

UP

C

D

E

G

1 2 3 4 5 6 7 8

38'-0" 36'-0" 36'-0" 36'-0" 46'-0" 36'-0" 36'-0" 38'-0"

FUTURE

ELEV

E3

ELEV

E2

ELEV

E1

204 SF

ELEV

EQUIP

STAIR

S1

82 SF

MECH

262 SF

ELEC

140 SF

IT

118 SF

SEC

STAIR

S2

TRAVEL DISTANCE (160')

TRAVEL DISTANCE (170')

TRAVEL DISTANCE (190') TRAVEL DISTANCE (170')

STAIR

S3

FEC

FEC

FEC

FEB

FEB

FEC

B

A

F

5.21.6 3.9 8.8

B.6

1'-0"

5.54.5 6.5 7.5

S2.1

101100S1.1

RAMP DOWN

SLOPE = 1:20

RAMP DOWN

SLOPE = 1:20

EXIT

SIGN

EXIT SIGN

BOLLARDS

BOLLARDS

AE701

AE401

AE702

DN

EGRESS PATH

FIRE EXTINGUISHER BRACKET

FIRE EXTINGUISHER CABINET

(SURFACE MOUNTED)

FEB

FEC

TOTAL SQUARE

FOOTAGE:

OCCUPANCY:

EGRESS

REQUIRED:

104,409 SF

STORAGE, ORDINARY HAZARD

500 SF / PERSON

223 OCCUPANTS

45" CLEAR, 2 DOORS @ 36" EACH

2 STAIRS REQ., 2 NEW STAIRS

STAIR WIDTH 44"

1. EGRESS WIDTH

(per IBC 1005.1) - EXIT DOORS =

36"/(0.20) = 180 PPL

# OF OCCUPANTS - 223

x 0.2 = 44.6" EGRESS WIDTH

2. EXIT STAIRS = 223 OCCUPANTS FLOOR

0.3 x 223 = 66.9"

EXISTING STAIRS WITH 36" DOORS

AND 44" WIDE STAIRS

EXIT ACCESS

TRAVEL

(per NFPA 101 42.8.2.6.1)

300'-0" MAXIMUM DISTANCE

NON-SPRINKLERED

REQUIRED # OF

EXITS

(per NFPA 101 7.4.2.1.1)

2 EXITS REQUIRED

2 EXITS PROVIDED

2 MINIMUM ≤ 500 OCCUPANTS

EGRESS STAIR

TREAD, 11"

RISE, 4" TO 7"

(PER NFPA 101 TABLE 7.2.2.2.1.16)

STAIR WIDTH, 44"

(PER NFPA 101 TABLE 7.2.2.2.1.16)

• CLASS 'A' EXTINGUISHER

• MOUNTING HEIGHT - TOP OF EXTINGUISHER 5'

MAX

• ORDINARY HAZARD

- 2A RATED

- MAX FLOOR AREA 11,250SF/F.E.

- MAX TRAVEL DIST. 75FT/F.E.

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

/1

/2

:1

:0

P

M C

U s e rs

\g g o n z a le s \D o c u m e n ts \A

-2

-O

K C

P a rk in g G a ra g e g g o n z a le s B

W J C

U .r v t

LS101

LEVEL 1 - LIFE SAFETY PLAN

3 4AT

PARKING GARAGE 2

921 NE 13TH STREET

OKLAHOMA CITY, OK 73104

July 8, 2022

100% CONSTRUCTION DOCUMENTS

635-41419-292

N/A

TM

PROPOSED USE:

OWNED BY: VETERANS ADMINISTRATION

CODE ENFORCEMENT JURISDICTION: FEDERAL

APPLICABLE CODES:

GENERAL CODE INFORMATION:

NEW CONSTRUCTION

NON-SPRINKLERED

CONSTRUCTION TYPE:

PRIMARY OCCUPANCY:

PROJECT NAME:

PROJECT ADDRESS:

OWNER OR AGENT:

PARKING GARAGE

TYPE I

PARKING GARAGE

2021 International Building Code

2021 Plumbing Code

2021 International Energy Conservation Code 2021 International Mechanical Code 2021 International Fire Code 2020 NFPA 70 National Electrical Code

2020 Architectural Barrier Act (ABA) Standard 2021 NFPA 101 Life Safety Code

2010 ADA Standard for Accessible Design

2017 PG 18-13 VA Barrier Free Design Standard

PARKING GARAGE 2

921 NE 13TH STREET

OKLAHOMA CITY, OK 73104

OKLAHOMA CITY VAMC

CODE INFORMATION

N O

R T

H0 84 16

Scale: 3/32" = 1'-0"

LEVEL 1 - LIFE SAFETY PLAN

LIFE SAFETY LEGEND

N

SCOPE OF WORK

KEY PLAN

SCALE: NO SCALE

AREA OF WORK

EGRESS INFORMATION

FIRE EXTINGUISHER INFO

DN

C

D

E

G

1 2 3 4 5 6 7 8

38'-0" 36'-0" 36'-0" 36'-0" 46'-0" 36'-0" 36'-0" 38'-0"

S1

STAIR

84 SF

ELEV

E1

84 SF

ELEV

E2

84 SF

FUTURE

ELEV

E3

375 SF

ELEV

LOBBY

S2

STAIR

TRAVEL DISTANCE (280')

TRAVEL DISTANCE (170')

TRAVEL DISTANCE (170')

TRAVEL DISTANCE (290')

FEC

FEC

FEC

FEC

FEC

B

A

F

5.21.6 3.9 8.8

B.6

5.54.5 6.5 7.5

S2.2

S1.2

EXIT

SIGN

EXIT

SIGN

BOLLARDS

BOLLARDS

AE701

AE702

EGRESS PATH

FIRE EXTINGUISHER BRACKET

FIRE EXTINGUISHER CABINET

(SURFACE MOUNTED)

FEB

FEC

TOTAL SQUARE

FOOTAGE:

OCCUPANCY:

EGRESS

REQUIRED:

104,409 SF

STORAGE, ORDINARY HAZARD

500 SF / PERSON

223 OCCUPANTS

45" CLEAR, 2 DOORS @ 36" EACH

2 STAIRS REQ., 2 NEW STAIRS

STAIR WIDTH 44"

1. EGRESS WIDTH

(per IBC 1005.1) - EXIT DOORS =

36"/(0.20) = 180 PPL

# OF OCCUPANTS - 223

x 0.2 = 44.6" EGRESS WIDTH

2. EXIT STAIRS = 223 OCCUPANTS FLOOR

0.3 x 223 = 66.9"

EXISTING STAIRS WITH 36" DOORS

AND 44" WIDE STAIRS

EXIT ACCESS

TRAVEL

(per NFPA 101 42.8.2.6.1)

300'-0" MAXIMUM DISTANCE

NON-SPRINKLERED

REQUIRED # OF

EXITS

(per NFPA 101 7.4.2.1.1)

2 EXITS REQUIRED

2 EXITS PROVIDED

2 MINIMUM ≤ 500 OCCUPANTS

EGRESS STAIR

TREAD, 11"

RISE, 4" TO 7"

(PER NFPA 101 TABLE 7.2.2.2.1.16)

STAIR WIDTH, 44"

(PER NFPA 101 TABLE 7.2.2.2.1.16)

• CLASS 'A' EXTINGUISHER

• MOUNTING HEIGHT - TOP OF EXTINGUISHER 5'

MAX

• ORDINARY HAZARD

- 2A RATED

- MAX FLOOR AREA 11,250SF/F.E.

- MAX TRAVEL DIST. 75FT/F.E.

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

/1

/2

:1

:0

P

M C

U s e rs

\g g o n z a le s \D o c u m e n ts \A

-2

-O

K C

P a rk in g G a ra g e g g o n z a le s B

W J C

U .r v t

LS102

LEVEL 2 - LIFE SAFETY PLAN

4 4AT

PARKING GARAGE 2

921 NE 13TH STREET

OKLAHOMA CITY, OK 73104

July 8, 2022

100% CONSTRUCTION DOCUMENTS

635-41419-292

N/A

TM

N O

R T

H0 84 16

Scale: 3/32" = 1'-0"

LEVEL 2 - LIFE SAFETY PLAN

N

SCOPE OF WORK

KEY PLAN

SCALE: NO SCALE

AREA OF WORK

PROPOSED USE:

OWNED BY: VETERANS ADMINISTRATION

CODE ENFORCEMENT JURISDICTION: FEDERAL

APPLICABLE CODES:

GENERAL CODE INFORMATION:

NEW CONSTRUCTION

NON-SPRINKLERED

CONSTRUCTION TYPE:

PRIMARY OCCUPANCY:

PROJECT NAME:

PROJECT ADDRESS:

OWNER OR AGENT:

PARKING GARAGE

TYPE I

PARKING GARAGE

2021 International Building Code

2021 Plumbing Code

2021 International Energy Conservation Code 2021 International Mechanical Code 2021 International Fire Code 2020 NFPA 70 National Electrical Code

2020 Architectural Barrier Act (ABA) Standard 2021 NFPA 101 Life Safety Code

2010 ADA Standard for Accessible Design

2017 PG 18-13 VA Barrier Free Design Standard

PARKING GARAGE 2

921 NE 13TH STREET

OKLAHOMA CITY, OK 73104

OKLAHOMA CITY VAMC

CODE INFORMATION

LIFE SAFETY LEGEND

EGRESS INFORMATION

FIRE EXTINGUISHER INFO

2022-07-18T16:32:51-0700
Digitally verifiable PDF exported from www.docusign.com

File details come from the government source that posted it. Updated .