This solicitation is for a parking garage construction project at the Oklahoma City VA Medical Center. The scope of work includes demolishing an existing solar panel array and guard shack; constructing a new four-level, 304-space parking garage with associated site work; and installing mechanical, electrical and technology systems. The estimated total cost is $12-15 million. The contract type will be firm-fixed-price. The solicitation was issued by the VA Technology Acquisition Center on behalf of the Oklahoma City VA Medical Center. The response due date is August 5, 2022 and award is expected by September 30, 2022. Small businesses are encouraged to compete for the opportunity.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AFF ABOVE FINISHED FLOOR
ACP/APC ACOUSTIC CEILING PANEL/
ACOUSTIC PANEL CEILING
ACT ACOUSTIC(AL) TILE
ADJ ADJUSTABLE
ADT'L ADDITIONAL
AGG AGGREGATE
ALT ALTERNATE
AL ALUMINUM
APPROX APPROXIMATE(LY)
ASPH ASPHALT
AUTO AUTOMATIC
B/O BOTTOM OF
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BOT BOTTOM
BRG BEARING
CENTERLINE
C/C CENTER TO CENTER
CJ CONTROL JOINT
CLL CONTRACT LIMIT LINE
CEM CEMENT(ITIOUS)
CMU CONCRETE MASONRY UNIT
CLG CEILING
CLR CLEAR
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CPT CARPET
CT CERAMIC TILE
CTR CENTER(ED)
DF DRINKING FOUNTAIN
DS DOWNSPOUT
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION
DET/DTL DETAIL
DIA DIAMETER
DIM DIMENSION
DN DOWN
DWG(S) DRAWING(S)
E EAST
EC ELECTRICAL CONTRACTOR
EHO ELECTRICAL HOLD OPEN
EJ EXPANSION JOINT
EW EACH WAY
EA EACH
EIFS EXTERIOR INSULATION
FINISH SYSTEM
EL ELEVATION
ELEC ELECTRIC(AL)
ELEV ELEVATOR
EMER EMERGENCY
EQ EQUAL
EQUIP EQUIPMENT
EXIST EXISTING
EXT EXTERIOR
EWC ELECTRIC WATER COOLER
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FFE FINISH FLOOR ELEVATION
FV FIELD VERIFY
FEC FIRE EXTINGUISHER CABINET
FDN FOUNDATION
FIN FINISH
FLSHG FLASHING
FLR FLOOR
FRMG FRAMING
FT FOOT/FEET
FTG FOOTING
GC GENERAL CONTRACTOR
GA GAUGE
GALV GALVANIZED
GEN GENERAL
GYP GYPSUM
HM HOLLOW METAL
HDWR HARDWARE
HOL HOLLOW
HOR HORIZONTAL
HT HEIGHT
HVAC HEATING/VENTILATION/AIR
CONDITIONING
ID INSIDE DIAMETER
IN INCH
INCL INCLUDING
INSUL INSULATION
INT INTERIOR
JAN JANITOR
JT JOINT
LAV LAVATORY
LB(S) POUND(S)
L/S LANDSCAPE
LT LIGHT
MO MASONRY OPENING
MAS MASONRY
MAT'L MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MTD MOUNTED
MTL METAL
N NORTH
NIC NOT IN CONTRACT
NTS NOT TO SCALE
NOM NOMINAL
OC ON CENTER
OD OUTSIDE DIAMETER
O TO O OUT TO OUT
OPNG OPENING
OPP OPPOSITE
OVHD OVERHEAD
PEB PRE-ENGINEERED BUILDING
PJF PREFORMED JOINT FILLER
PT PRESSURE TREATED
PERIM PERIMETER
PL PLATE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
PNT PAINT
PR PAIR
PTD PAINTED
PWR POWER
RB RUBBER BASE
RD ROOF DRAIN
RO ROUGH OPENING
RAD RADIUS
REC RECESSED
REINF REINFORCED
REQ'D REQUIRED
REV REVISED (REVISION)
RM ROOM
S SOUTH
SB SPLASH BLOCK
SF SQUARE FEET
SS STAINLESS STEEL
SIM SIMILAR
SPEC SPECIFICATIONS
SQ SQUARE
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
T&G TONGUE AND GROOVE
T/O TOP OF
TELE TELEPHONE
TRTD TREATED
TS TUBE STEEL
TYP TYPICAL
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITION TILE
VIF VERIFY IN FIELD
VERT VERTICAL
W WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WWF WELDED WIRE FABRIC
WD WOOD
WH WATER HEATER
WT WEIGHT
CL
DEMOLITION KEYNOTE
WINDOW TYPE
TOILET ACCESSORY
ROOF PITCH SYMBOL
DOOR NUMBER
TYPICAL KEYNOTE CEILING/ SOFFIT
HEIGHT
MATL
1'-0"
1 #
1. INDICATIONS OF PROJECT LIMITS OR LINES OF DEMARCATION ARE SHOWN FOR GENERAL SCOPE DEFINITION AND REFLECT THE UNDERSTANDING OF THE DESIGNER AS TO THE LIMITATIONS OF THE WORK AREA IN AN OCCUPIED AREA. ACTUAL CONTRACT LIMITS ARE TO BE DETERMINED BY AGREEMENT BETWEEN THE COR AND
CONTRACTOR BEFORE THE START OF THE WORK.
2. DRAWINGS ARE PREPARED USING PRODUCT DIMENSIONS AND DETAILS FROM BASIS OF DESIGN PRODUCT. PRODUCTS MAY CHANGE IN DIMENSION AND DETAIL BEFORE THEY ARE INCORPORATED INTO WORK. PRODUCTS FROM OTHER MANUFACTURER’S ARE ALSO ACCEPTABLE. DIMENSIONS AND DETAILS FOR ALTERNATE PRODUCTS MAY VARY FROM BASIS OF DESIGN. CONTRACTOR SHALL VERIFY INSTALLATION REQUIREMENTS FOR ALL PRODUCTS TO BE INCORPORATED INTO WORK (INCLUDING THICKNESS FOR RECESSED OR SEMI-RECESSED PRODUCTS) AND IS RESPONSIBLE FOR ACCOMMODATING AND COORDINATING CHANGES TO OTHER MATERIALS OR
PRODUCTS THAT ARE NECESSARY BECAUSE OF THESE DIFFERENCES.
3. THE DRAWINGS AND SPECIFICATIONS ARE SEPARATED INTO DISCIPLINES FOR CONVENIENCE. THE SEPARATIONS ARE USED ONLY FOR THE PURPOSES OF CONVENIENCE AND REFERENCE AND IN NO WAY DO THEY DEFINE OR LIMIT THE SCOPE OR INTENT OF ANY PART OF THE DRAWINGS AND SPECIFICATIONS AS A WHOLE.
THE FACT THAT THE DRAWINGS ARE SEPARATED IN NO WAY SUGGESTS THAT THE WORK IS NOT TO BE CONSTRUCTED AS A COMPLETE, INTEGRATED AND UNIFIED
WHOLE.
4. THE DRAWINGS AND SPECIFICATIONS, INCLUDING DRAWINGS PREPARED BY SPECIFIC ENGINEERING DISCIPLINES ARE COMPLEMENTARY; ITEMS SHOWN IN ANY ONE LOCATION IN THE DRAWINGS SHALL BE CONSIDERED TO BE REQUIREMENTS OF THE CONTRACT FOR CONSTRUCTION. IN THE EVENT OF AN INCONSISTENCY BETWEEN THE DRAWINGS AND SPECIFICATIONS, OR WITHIN EITHER DOCUMENT, THE CONTRACTOR SHALL SEEK CLARIFICATION OR INTERPRETATION FROM THE COR PRIOR TO BIDDING. WHERE INCONSISTENCIES ARE NOT CLARIFIED PRIOR TO BIDDING, AND WHERE THE ACTUAL SOLUTION OR INTENT CANNOT BE REASONABLY INFERRED, THE
CONTRACTOR SHALL PROVIDE THE BETTER QUALITY OR GREATER QUANTITY OF WORK.
5. THE CONTRACTOR SHALL NOTIFY THE COR IMMEDIATELY SHOULD DISCREPANCIES BE FOUND IN THE DRAWINGS AND SPECIFICATIONS.
6. THE CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL FIELD CONDITIONS AND DIMENSIONS AS THEY RELATE TO THIS PROJECT, FOR EACH PHASE. SHOULD DISCREPANCIES EXIST BETWEEN THE WORK INDICATED AND ACTUAL FIELD CONDITIONS, NOTIFY THE COR PRIOR TO PROCEEDING WITH THE WORK.
7. DO NOT SCALE THE DRAWINGS. DRAWING SCALES AS INDICATED ARE FOR REFERENCE ONLY AND ARE NOT INTENDED TO ACCURATELY DEPICT ACTUAL OR
DESIGNATED CONDITIONS. WRITTEN DIMENSIONS SHALL GOVERN.
8. PROVIDE SEALANT AT ALL INTERSECTIONS BETWEEN DIFFERENT MATERIALS.
9. COORDINATE WORK OF ALL TRADES PRIOR TO STARTING CONSTRUCTION.
10. REFER TO ALL OTHER TRADE DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION ON THIS PROJECT.
11. PROVIDE BLOCKING AT PARTITIONS AS REQUIRED FOR MOUNTING OF WALL-MOUNTED ITEMS: PROVIDE SUPPLEMENTAL FRAMING AT WALL OPENINGS INCLUDING KING
STUDS, JACK STUDS, AND CRIPPLE STUDS, AS REQUIRED FOR COMPLETION OF THE WORK.
12. DIMENSIONS SHOWN ARE TO FACE OF STUD FRAMING, FACE OF CONCRETE/MASONRY WALLS, OR FINISHED FACE OF EXISTING WALL SURFACE.
13. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED.
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:1
:5
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AG001
ARCHITECTURAL SYMBOLS,
ABBREVIATIONS AND NOTES
1 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
TM
ABBREVIATIONS
ARCHITECTURAL SYMBOL LEGEND
GENERAL NOTES
DocuSign Envelope ID: B1166ACB-C743-4AF3-A46A-6D7C174A0143
7/18/2022
In d i a n N a tio n s T e le
In d i a n N a tio n T e le
B u s h
B u s h
B u s h
B u s h
B u s h
B u s h
B u s h
B u s h
B u s h
B u s h
B u s h
B u s h
EXISTING VAMC BUILDING
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:1
:2
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AD100
ARCHITECTURAL SITE PLAN -
DEMOLITION
2 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
TM
N
KEY PLAN
SCALE: NO SCALE
Scale: 1" = 30'-0"
ARCHITECTURAL SITE PLAN - DEMOLITION
1 EXISTING SOLAR PANEL ARRAY COVERING THE
EXISTING PARKING AREA TO BE DEMOLISHED AND
REMOVED FROM SITE.
2 EXISTING GUARD SHACK TO BE DEMOLISHED AND
REMOVED FROM SITE.
3 EXISTING MANHOLE FOR IT/SECURITY TO REMAIN,
SEE CIVIL DRAWINGS FOR EXACT LOCATION.
4 EXISTING MECHNICAL YARD WITH ALL SOLAR
ARRAY EQUIPMENT TO BE DEMOLISHED, SEE
ELECTRICAL DRAWINGS. FOR DEMOLITION OF
EXISTING EQUIPMENT.
N O
R T
H0 3015 60
A. SEE CIVIL DRAWINGS FOR ALL SITE AND UTILITY
DEMOLITION REQUIRE IN ADDITION TO
DEMOLITION SHOWN ON THIS SHEET.
B. SEE CIVIL DRAWINGS FOR ALL SITE PHASING
REGARDS SITE UTILITIES WORK, LANDSCAPE
WORK AND NEW PARKING STRUCTURE.
C. SEE TECHNOLOGY DRAWINGS FOR ALL SITE
O.I.T, SECURITY AND FIRE ALARM
REQUIREMENTS.
D. SEE CIVIL DRAWINGS FOR MECHANICAL YARD
LAYOUT/PROFILE.
E. SEE STRUCTURAL DRAWINGS FOR SITE
DEMOLITION REQUIREMENTS AND SITE
ELEMENTS BEING REMOVED.
PROPOSED
PARKING
GARAGE
B u sh
B u sh
B u sh
B u sh
B u sh
B u sh
B u sh
B u sh
B u sh
E
IT/SECURITY
1G130
EXISTING VAMC BUILDING
EXISTING PARKING GARAGE
FIRE ALARM
ROOM
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:1
:2
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AE100
ARCHITECTURAL SITE PLAN
3 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
TM
N
SCOPE OF WORK
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
Scale: 1" = 30'-0"
ARCHITECTURAL SITE PLAN
N O
R T
H0 3015 60
1 ENTRY GUARD HOUSE SEE CIVIL DRAWINGS FOR
LAYOUT, AND SEE SPECIFICTIONS SECTION 13 34
19" METAL BUILDING SYSTEMS.
2 EMERGENCY GENERATOR FOR PARKING DECK
3 NEW PARKING STRUCTURE - PARKING GARAGE Z
4 NEW STAIR/ELEVATOR TOWER SERVING THE NEW
PARKING STRUCTURE
5 NEW EGRESS STAIR TOWER SERVICING THE NEW
PARKING DECK.
6 NEW STANDING SEAM METAL ROOF CANOPY OVER
EXTERIOR CONCRETE WALL
7 EXSITING I.T/SECURITY MANHOLE TO- TIE INTO THE
EXISTING SYSTEMS SEE CIVIL DRAWINGS FOR
EXACT LOCATIONS OF EXISTING UTILITIES
8 LOCATION EXISTING I.T./SECURITY ROOM 1G130,
EXSITNG TELECOM ROOM, COORDINATE WITH
C.O.R FOR ACCESS TO SPACE.
9 LOCATION EXISTING FIRE ALARM ROOM GR100,
FIRE ALARM ROOM, COORDINATE WITH C.O.R FOR
ACCESS TO SPACE.
10 NEW MANHOLE FOR O.I.T, SECUIRTY AND FIRE
ALARM FOR THE NEW PARKING GARAGE, SEE CIVIL
DRAWINGS FOR M.H. REQUIRMENT AND EXACT
LOCATION.
11 OUTLINE OF ENTRY CANOPY AT GUARD HOUSE
SEE CIVIL DRAWINGS FOR COLUMN LAYOUT AND
SPACING, SEE SPEC SECTON 13 34 19" METAL
BUILDING SYSTEMS FOR BUILDING
CONSTRUCTION.
12 STEEL BOLLARDS, SEE CIVIL DRAWINGS FOR SITE
BOLLARD LOCATIONS, SEE STRUCTURAL
DRAWINGS FOR BOLLARD DETAILS, SEE
SPECIFICATION SECTION 05 50 00.
A. SEE CIVIL DRAWINGS FOR ALL SITE GRADING
REQUIREMENT, UTILITY WORK AND RELOCATION
OF STRUCTURES NOT SHOWN ON THIS SHEET.
B. SEE LANDSCAPE DRAWINGS TO SEE
LANDSCAPE WORK TO BE PERFORMED AS PART
OF THIS CONTRACT.
C. SEE CIVIL DRAWINGS FOR ALL SITE PHASING
REGARDING SITE UTILITIES WORK, LANDSCAPE
WORK AND NEW PARKING STRUCTURE.
D. SEE TECHNOLOGY DRAWINGS FOR ALL SITE
O.I.T, SECURITY AND FIRE ALARM
REQUIREMENTS.
E. SEE STRUCTURAL DRAWINGS FOR SITE
DEMOLITION REQUIREMENTS FOR EXISTING
SOLAR ARRAY AND OTHER SITE ELEMENTS
BEING REMOVED.
F. SEE SPECIFICATION SECTION 13 34 19 " METAL
BUILDING SYSTEMS " FOR DESIGN OF THE
ENTRY GUARD HOUSE AND CANOPY
REQUIREMENTS.
UP
AE201
2_____
AE201
3_____
AE201
1_____
AE201
4_____
C
D
E
G
1 2 3 4 5 6 7 8
140 SF
IT
262 SF
ELEC
118 SF
SEC
ELEV
E2
ELEV
E1
204 SF
ELEV
EQUIP
100 82 SF
MECH
101STAIR
S1
STAIR
S2
AE402
AE701
AE702
AE401
AE301
_____3
AE301
AE301
_____2
AE301
AE302
AE302
AE302
AE302
AE202
2_____
AE202 4
AE202
AE202
6_____
AE301
_____1
AE301
1 2
RAMP DOWN
SLOPE = 1:20
RAMP DOWN
SLOPE = 1:20
AE202
1_____
STAIR
S3
RAMP UP
VEHICLE
S2.1
8 89 9
B
A
F
5.2
AE304
1.6
3.9 8.8
B.6
5.5
100 101
4.5 6.5 7.5
AE304
22'-6" 15'-6" 36'-0" 36'-0" 36'-0" 10'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 28'-6" 9'-6"
304'-0"
40'-0"
S1.1
10 10 10 10 12 12 12
AE303
AE303
DN
W5B
13 13
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
/1
/2
:1
:3
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AE101
LEVEL 1 - FLOOR PLAN
4 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
TM
N O
R T
H0 84 16
Scale: 3/32" = 1'-0"
LEVEL 1 - FLOOR PLAN
N
SCOPE OF WORK
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
A. SEE DRAWING AP101 FOR STRIPING PLAN THIS
LEVEL.
B. SEE STRUCTURAL DRAWINGS FOR ALL
STRUCTURAL DESIGN ELEMENTS. INCLUDING ALL
STRUCTURAL PRECAST PANELS, SPANDRELS,
BEAM/ GIRDERS, OTHER STRUCTURAL MEMBERS.
C. SEE PLUMBING DRAWINGS FOR COORDINATION
OF ROOF/FLOOR DRAWINGS AND PIPING.
D. SEE FIRE PROTECTION DRAWINGS FOR FIRE
RISER INFORMATION.
E. SEE MECHANICAL DRAWINGS FOR WORK
REQUIREMENTS.
F. SEE ELECTRICAL DRAWINGS FOR ELECTRICAL
AND LIGHTING REQUIREMENTS.
G. SEE STRUCTURAL DRAWINGS FOR ALL
ELEVATION AT DECK LEVELS INSIDE
STRUCTURAL DECK.
H. SEE ARCHITECTURAL PARKING DRAWINGS (AP)
FOR ALL PARKING LAYOUTS AND INTERNAL
SIGNAGE FOR ENTIRE PARKING GARAGE.
1 CAST-IN-PLACE CONCRETE STAIRS
2 STEEL PIPE HANDRAIL
3 ADA COMPLIANT RAMP, 1 TO 20 SLOPE, 30' MAX
TRAVEL BETWEEN LANDINGS.
4 ELEVATOR SHAFT TO BE CONSTRUCTED AS PART
OF THIS PROJECT FOR FUTURE ELEVATOR E3.
5 PRECAST CONCRETE PANELS, SEE STRUCTURAL
DRAWINGS. PRECASTER TO PROVIDE SCREEN IN
OPENING FOR FALL PREVENTION.
6 PRECAST CONCRETE PANELS WITH TEXTURED
FINISH, SEE STRUCTURAL DRAWINGS.
7 COVERED WALKWAY AT FIRST FLOOR OF PARKING
STRUCTURE.
8 STEEL COLUMNS TO SUPPORT CANOPY OVER
WALKWAY. ON TOP OF CONCRETE WALL.
9 OVERHANG OF SSMR CANOPY OVER WALK
STAIR/RAMP ABOVE.
10 FALL PROTECTION ALUMINUM FRAME AND MESH
SECURED TO PRECAST AND COLUMNS.
11 8" CMU INFILL BETWEEN P.C STRUCTURAL
MEMBERS, SEE STRUCTURAL DRAWINGS P.C.
MEMBERS.
12 CAST IN PLACE CONCRETE FOUNDATION WALLS,
SEE STRUCTURAL DRAWINGS.
13 OUTLINE OF ROOF CANOPY ABOVE.
14 8" CMU INFILL BETWEEN P.C STRUCTURAL
MEMBERS, SEE STRUCTURAL DRAWINGS P.C.
MEMBERS.
15 STEEL BOLLARDS @ 6'-0" O.C., FOLLOW THE
PARKING STRIPPING, SEE STRUCTURAL DRAWINGS
FOR BOLLARD DETAIL
DN
AE201
2_____
AE201
3_____
AE201
1_____
AE201
4_____
C
D
E
G
1 2 3 4 5 6 7 8
ELEV
E2
ELEV
E1
STAIR
S1
AE702
AE701
AE301
_____3
AE301
AE301
_____2
AE301
AE302
AE302
AE302
AE302
AE202
2_____
AE202 4
AE202
AE202
6_____
375 SF
ELEV
LOBBY
AE301
_____1
AE301
RD OFD
OPEN TO BELOW
RAMP DOWN
VEHICLE
RAMP UP
VEHICLE
STAIR
S2
S2.2
S1.2
B
A
F
5.2
AE304
1.6
3.9 8.8
B.6
5.54.5 6.5 7.5
AE304
22'-6" 15'-6" 36'-0" 36'-0" 36'-0" 10'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 28'-6" 9'-6"
304'-0"
9 9 9 999
8 8
AE303
AE303
W1
W6
W1
W2
W5A
W4
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
/1
/2
:1
:3
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AE102
LEVEL 2 - FLOOR PLAN
5 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
TM
N O
R T
H0 84 16
Scale: 3/32" = 1'-0"
LEVEL 2 - FLOOR PLAN
N
SCOPE OF WORK
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
A. SEE DRAWING AP101 FOR STRIPING PLAN THIS
LEVEL.
B. SEE STRUCTURAL DRAWINGS FOR ALL
STRUCTURAL DESIGN ELEMENTS. INCLUDING ALL
STRUCTURAL PRECAST PANELS, SPANDRELS,
BEAM/ GIRDERS, OTHER STRUCTURAL MEMBERS.
C. SEE PLUMBING DRAWINGS FOR COORDINATION
OF ROOF/FLOOR DRAWINGS AND PIPING.
D. SEE FIRE PROTECTION DRAWINGS FOR FIRE
RISER INFORMATION.
E. SEE MECHANICAL DRAWINGS FOR WORK
REQUIREMENTS.
F. SEE ELECTRICAL DRAWINGS FOR ELECTRICAL
AND LIGHTING REQUIREMENTS.
G. SEE STRUCTURAL DRAWINGS FOR ALL
ELEVATION AT DECK LEVELS INSIDE
STRUCTURAL DECK.
H. SEE ARCHITECTURAL PARKING DRAWINGS (AP)
FOR ALL PARKING LAYOUTS AND INTERNAL
SIGNAGE FOR ENTIRE PARKING GARAGE.
1 ALUMINUM CURTAIN WALL SYSTEM WINDOWS AT
STAIRS OF PARKING GARAGE
2 PRECAST CONCRETE STAIRS AND LANDINGS
3 STANDING SEAM METAL ROOF SYSTEM OVER
STEEL STRUCTURE SEE SECTIONS 1/AE304 AND
2/AE304.
4 ELEVATOR SHAFT TO BE CONSTRUCTED AS PART
OF THIS PROJECT FOR FUTURE ELEVATOR E3.
5 COVERED WALKWAY AT LEVEL OF PARKING
STRUCTURE.
6 ALUMINUM STOREFRONT, ENCLOSURE TO FORM
ELEVATOR LOBBY AREA ROOM 200.
7 PRECAST CONCRETE PANELS WITH TEXTURED
FINISH, SEE STRUCTURAL DRAWINGS.
8 PRECAST CONCRETE PANELS, SEE STRUCTURAL
DRAWINGS. PRECASTER TO PROVIDE SCREEN IN
OPENING FOR FALL PREVENTION.
9 FALL PROTECTION ALUMINUM FRAME AND MESH
SECURED TO PRECAST AND COLUMNS.
10 8" CMU INFILL BETWEEN P.C STRUCTURAL
MEMBERS, SEE STRUCTURAL DRAWINGS P.C.
MEMBERS.
11 STEEL BOLLARDS @ 6'-0" O.C., SEE STRUCTURAL
DRAWINGS FOR BOLLARD DETAILS.
12 STEEL BOLLARDS @ 6'-0" O.C., FOLLOW THE
PARKING STRIPPING, SEE STRUCTURAL DRAWINGS
FOR BOLLARD DETAIL.
2_____
AE201
3_____
AE201
1_____
AE201
4_____
C
D
E
G
1 2 3 4 5 6 7 8
AE301
_____3
AE301
AE301
_____2
AE301
AE302
AE302
AE302
AE302
AE301
_____1
AE301
RD OFD
RD
OFD
OPEN TO BELOW
RD OFD
B
A
F
5.2
AE304
56 6 6 6 65 5
1.6 3.9 8.8
B.6
5.54.5 6.5 7.5
38'-0" 36'-0" 36'-0" 36'-0" 10'-0" 36'-0" 36'-0" 36'-0" 38'-0"
AE304
12 12
AE303
AE303
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
/1
/2
:1
:3
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AE103
ROOF PLAN
6 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
TM
N
SCOPE OF WORK
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
Scale: 3/32" = 1'-0"
ROOF PLAN
N O
R T
H0 84 16
1 ALUMINUM CURTAIN WALL SYSTEM WINDOWS AT
STAIRS OF PARKING GARAGE
2 COVERED WALKWAY AT FIRST FLOOR OF PARKING
STRUCTURE.
3 STANDING SEAM METAL ROOF SYSTEM OVER
STEEL STRUCTURE SEE DETAIL XX/AEXX.
4 NEW TPO ROOF SYSTEM OVER RIGID INSULATION
MIN R-25.
5 METAL GUTTERS ATTACED TO EDGE OF METAL
DECK/BENT PLAT. MATCH COLOR AND FINISH OF
SSMR.
6 METAL DOWN SPOUTS LOCATED AS INDICATED AT
CANOPY COLUMNS, MATCH COLOR AND FINISH OF
SSMR.
7 ROOF DRAIN WITH OFVERFLOW DRAIN 1'-0" APART
MINMUM.
8 PRECAST PARAPET CONTINUATION OF
STRUCTURAL P.C. PANEL ABOVE ROOF.
9 CMU WALLS WITH TEXTURED FINISH UP TO TOP OF
PARAPET.
10 CMU PARAPET WALLS AT TOP OF STAIRS.
11 PRECAST CONCRETE PANELS WITH TEXTURED
COATING
12 FALL PROTECTION ALUMINUM FRAME AND MESH
SECURED TO PRECAST AND COLUMNS.
A. SEE DRAWING AP101 FOR STRIPING PLAN THIS
LEVEL.
B. SEE STRUCTURAL DRAWINGS FOR ALL
STRUCTURAL DESIGN ELEMENTS. INCLUDING ALL
STRUCTURAL PRECAST PANELS, SPANDRELS,
BEAM/ GIRDERS, OTHER STRUCTURAL MEMBERS.
C. SEE PLUMBING DRAWINGS FOR COORDINATION
OF ROOF/FLOOR DRAWINGS AND PIPING.
D. SEE FIRE PROTECTION DRAWINGS FOR FIRE
RISER INFORMATION.
E. SEE MECHANICAL DRAWINGS FOR WORK
REQUIREMENTS.
F. SEE ELECTRICAL DRAWINGS FOR ELECTRICAL
AND LIGHTING REQUIREMENTS.
G. SEE STRUCTURAL DRAWINGS FOR ALL
ELEVATION AT DECK LEVELS INSIDE
STRUCTURAL DECK.
H. SEE ARCHITECTURAL PARKING DRAWINGS (AP)
FOR ALL PARKING LAYOUTS AND INTERNAL
SIGNAGE FOR ENTIRE PARKING GARAGE.
OS OS OS
2_____
AE201
3_____
AE201
1_____
AE201
4_____
C
D
E
G
1 2 3 4 5 6 7 8
AE301
_____3
AE301
AE301
_____2
AE301
AE302
AE302
AE302
AE302
AE202
2_____
AE202 4
AE202
AE202
6_____
AE301
_____1
AE301
AE202
3_____
AE202
1_____
1 1
IT
ELEC
SEC
ELEV
EQUIP
MECH
FUTURE
ELEV
E3
STAIR
S1
ELEV
E1
ELEV
E2
STAIR
S2
B
A
F
5.2
AE304
6 6 6
1.6 3.9 8.8
B.6
5.54.5 6.5 7.5
AE304
7 8
AE402
AE303
AE303
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
/1
/2
:1
:3
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AE111
LEVEL 1 - REFLECTED CEILING PLAN
7 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
TM
N
SCOPE OF WORK
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
Scale: 3/32" = 1'-0"
LEVEL 1 - REFLECTED CEILING PLAN
1 NEW LIGHT FIXTURES, SEE ELECTRICAL
DRAWINGS FOR TYPE AND SIZES.
2 ELEVATOR CAB. FOR HYDRAULIC ELEVATOR TO
BE INSTALLED AS PART OF THIS PROJECT.
3 FUTURE HYDRAULIC ELEVATOR SHAFT, SHAFT TO
BE CONSTRUCTED AS PART OF THIS PROJECT
ONLY.
4 PRECAST CONCRETE STRUCTURAL SYSTEM, SEE
STRUCTURAL DRAWINGS. TYPICAL THROUGHOUT.
5 STANDING SEAM METAL ROOF COVER OVER
STAIR/RAMP/WALK OVER AREAS INDICATED.
6 EXIT SIGNAGE FOR PARKING STRUCTURE
VEHICLE TRAFFIC. EXIT SIGNAGE MUST EXTEND
BELOW STRUCTURAL ELEMENTS.
7 COLUMNS UP FROM CONCRETE WALL, SEE
STRUCTURAL DRAWINGS FOR SIZE OF
STRUCTURAL MEMBERS.
8 STEEL BEAMS W/METAL DECKING, ON TOP, SEE
STRUCTURAL DRAWINGS FOR SIZES OF
STRUCTURAL MEMBERS.
A. SEE ELECTRICAL DRAWINGS FOR INFORMATION
ABOUT LIGHTS AND SENSORS INSTALLED ON
CEILING PLAN.
B. SEE PLUMBING DRAWINGS FOR COORDINATION
OF ROOF/FLOOR DRAINS AND PIPING.
C. SEE FIRE PROTECTION DRAWINGS FOR FIRE
RISER INFORMATION.
D. SEE MECHANICAL DRAWINGS FOR WORK
REQUIREMENTS.
E. SEE ELECTRICAL DRAWINGS FOR ELECTRICAL
AND LIGHTING REQUIREMENTS.
F. EXIT SIGNS LOCATED ABOVE DOOR TO EGRESS
STAIR.
G. SEE ARCHITECTURAL PARKING DRAWINGS (AP)
FOR ALL PARKING LAYOUTS AND INTERNAL
SIGNAGE FOR ENTIRE PARKING GARAGE.
N O
R T
H0 84 16
OS OSOS
G
AE702
AE702
F
8.8
C
2 3
AE701
AE302
AE302
AE401
AE202
3_____
AE303
2 2
B
A
AE304
1.6
B.6
7 6
AE303
8 8
9 9
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
/1
/2
:1
:3
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AE112
ENLARGED SECOND FLOOR
REFLECTED CEILING PLANS
8 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
TM
N
SCOPE OF WORK
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
Scale: 1/4" = 1'-0"
LEVEL 2 - ENLARGED
REFLECTED CEILING PLAN
NE STAIR
Scale: 1/4" = 1'-0"
LEVEL 2 - ENLARGED REFLECTED CEILING PLAN SW STAIR
A. SEE ELECTRICAL DRAWINGS FOR INFORMATION
ABOUT LIGHTS AND SENSORS INSTALLED ON
CEILING PLAN.
B. SEE PLUMBING DRAWINGS FOR COORDINATION
OF ROOF/FLOOR DRAINS AND PIPING.
C. SEE FIRE PROTECTION DRAWINGS FOR FIRE
RISER INFORMATION.
D. SEE MECHANICAL DRAWINGS FOR WORK
REQUIREMENTS.
E. SEE ELECTRICAL DRAWINGS FOR ELECTRICAL
AND LIGHTING REQUIREMENTS.
F. EXIT SIGNS LOCATED ABOVE DOOR TO EGRESS
STAIR.
G. SEE ARCHITECTURAL PARKING DRAWINGS (AP)
FOR ALL PARKING LAYOUTS AND INTERNAL
SIGNAGE FOR ENTIRE PARKING GARAGE.
1 NEW LIGHT FIXTURES, SEE ELECTRICAL DRAWINGS
FOR TYPE AND SIZES.
2 HOIST BEAM ABOVE ELEVATOR CAB, SEE
STRUCTURAL DRAWINGS.
3 EXIT SIGNS LOCATED ABOVE DOOR TO EGRESS
STAIR.
4 GYPSUM BOARD CEILING IN LOBBY AREA
CONSTRUCTED WITH MOISTER RESISTANT GYPSUM
BOARD ON LIGHT GAUGE METAL FRAMING..
5 STOREFRONT.
6 EXPOSED CONCRETE DECK W/ TEXTURING FINISH.
7 EXPOSED CONCRETE PRE CAST BEAM.
8 FALL PROTECTION ALUMINUM FRAME AND MESH
SECURED TO PRECAST PANEL AND COLUMNS. SEE
SPECIFICATION SECTION 05 50 00
9 STRUCTURAL BEAM FOR ELEVATOR RAILS BETWEEN
ELEVATOR CABS, SEE STRUCTURAL DRAWINGS FOR
BEAM SIZES AND INFORMATION
N O
R T
H0 2 4 8
N O
R T
H0 2 4 8
LEVEL 1 SW STAIR
0"
LEVEL 2 SW STAIR
11' - 4"
FUTURE LEVEL 3
22' - 8"
ROOF
25' - 8"
C
LOWER LEVEL
-4' - 0"
DEG
AE301
AE301
AE301
AE301
AE301
AE301
63 6
5 1
B AF
LEVEL 1
0"
B.6
12 12
5 5
OPEN
BEYOND
OPEN
BEYOND
W5A
W5B
LEVEL 1 SW STAIR
0"
LEVEL 2 SW STAIR
11' - 4"
FUTURE LEVEL 3
22' - 8"
91 2 3 4 5 6 7 8
AE302
AE302
AE302
AE302
5.21.6 3.9 8.85.54.5 6.5 7.5
W4
LEVEL 1 SW STAIR
0"
FUTURE LEVEL 3
22' - 8"
ROOF
25' - 8"
C
LOWER LEVEL
-4' - 0"
D E G
AE301
AE301
AE301
AE301
AE301
AE301
5 8 9
6 3 76
BA F
LEVEL 1
0"
B.6
5 5
AE303
OPEN BEYOND
W6
OPEN BEYOND
LEVEL 1 SW STAIR
0"
LEVEL 2 SW STAIR
11' - 4"
FUTURE LEVEL 3
22' - 8"
ROOF
25' - 8"
LOWER LEVEL
-4' - 0"
12345678
AE302
AE302
AE302
AE302
610106
5.2
AE304
1.6
TOP OF BEAM
17' - 0"
3.98.8
1 1
5.5 4.56.57.5
AE304
AE303
OPEN
BEYOND
14 14 14 14 14
W1
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:1
:4
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AE201
EXTERIOR ELEVATIONS
9 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
TM
Scale: 3/32" = 1'-0"
NORTH ELEVATION
Scale: 3/32" = 1'-0"
EAST ELEVATION
Scale: 3/32" = 1'-0"
SOUTH ELEVATION
Scale: 3/32" = 1'-0"
WEST ELEVATION
1 FACE BRICK VENEER WITH PRECAST CONCRETE
PANEL BACKUP STRUCTURE.
2 ARCHITECTURAL PRECAST CONCRETE WITH
CUSTOM ETCHED RELIEF PATTERN
3 PRECAST CONCRETE PANELS WITH TEXTURED
COATING
4 ALUMINUM CURTAIN WALL SYSTEM WINDOWS AT
STAIRS OF PARKING GARAGE WITH SPANDRAL
PANELS AT THE PRECAST BEAMS.
5 CAST-IN-PLACE CONCRETE WITH TEXTURED
COATING
6 ALUMINUM MESH SYSTEM WITH ALUMINUM FRAME
BETWEEN PRECAST CONCRETE MEMBERS, SUCIDE
FALL PREVENTION SYSTEM.
7 EXTERIOR SIGNAGE
8 CAST-IN-PLACE CONCRETE STAIR
9 STEEL TUBE HANDRAIL
10 STEEL FRAMED CANOPY WITH STANDING SEAM
METAL ROOF SEE STRUCTURAL DRAWINGS FOR
FRAMING REQUIREMENTS.
11 CMU PARAPET WALL AT ROOF LEVEL WITH
TEXTURED FINISH MATCHING ALL ADJACENT
SURFACES.
12 CONCRETE COLUMN WITH TEXTURED FINISH
MATCHING ALL ADJACENT SURFACES.
13 CONSTRUCTION/CONTRACTION JOINTS IN
CONCRETE FOUNDATION WALL, SEE STRUCTURAL
DRAWINGS FOR EXACT LOCATION , JOINT TYPE AND
DETAILS
14 OPENINGS IN CAST-IN-PLACE CONCRETE
N
SCOPE OF WORK
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
A. SEE CIVIL DRAWINGS FOR ALL ELEVATIONS AT
GRADE AROUND THE PARKING STRUCTURE.
B. SEE STRUCTURAL DRAWINGS FOR ALL
ELEVATIONS AT ALL DECK LEVELS INSIDE THE
PARKING STRUCTURE.
FUTURE LEVEL 3
22' - 8"
AE702
LEVEL 02 NE STAIR
11' - 7"
3 8
8.8
OPEN
BEYOND
W4
LEVEL 2 SW STAIR
11' - 4"
FUTURE LEVEL 3
22' - 8"
G
AE702
LEVEL 01 NE STAIR
-1' - 2"
F
LEVEL 1 SW STAIR
0"
LEVEL 2 SW STAIR
11' - 4"
FUTURE LEVEL 3
22' - 8"
AE702
LEVEL 01 NE STAIR
-1' - 2"
8.8
FUTURE LEVEL 3
22' - 8"
G
AE702
LEVEL 01 NE STAIR
-1' - 2"
F
OPEN
BEYOND
W5A
W5B
LEVEL 1 SW STAIR
0"
LEVEL 2 SW STAIR
11' - 4"
FUTURE LEVEL 3
22' - 8"
ROOF
25' - 8"
LOWER LEVEL
-4' - 0"
AE302
AE302
AE303
16'-0" 12'-0" 16'-0" 12'-0" 15'-11 1/2" 8'-6 1/2"
1 1 1
1.6
TOP OF BEAM
17' - 0"
3.9
10 10
AE303
3'-0" 5'-2"
3'-0" 9'-9 1/2"
3'-0" 9'-5 1/2"
5'-1" 3'-4"
3'-0" 3'-1 1/2"
7'-0" 3'-4"
3'-0" 10'-4"
3'-0" 3'-1 1/2"
6'-7 1/2" 2'-10"
EQ. EQ. EQ. EQ.
18 18
16 1617
W16 19
19 21 21
LEVEL 1 SW STAIR
0"
LEVEL 2 SW STAIR
11' - 4"
AE701
BA
LEVEL 1
0"
TOP OF BEAM
17' - 0"
B.6
AE303
W6
19 21
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:1
:4
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AE202
EXTERIOR ELEVATIONS
10 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
TM
Scale: 1/4" = 1'-0"
EAST ELEVATION - NE STAIR TOWER
Scale: 1/4" = 1'-0"
SOUTH ELEVATION - NE STAIR TOWER
Scale: 1/4" = 1'-0"
WEST ELEVATION - NE STAIR TOWER
Scale: 1/4" = 1'-0"
NORTH ELEVATION - NE STAIR TOWER
Scale: 1/4" = 1'-0"
WEST ELEVATION - STAIR/ELEVATOR TOWER
Scale: 1/4" = 1'-0"
SOUTH ELEVATION - STAIR/ELEVATOR TOWER
1 FACE BRICK VENEER WITH PRECAST CONCRETE
PANEL BACKUP STRUCTURE.
2 ARCHITECTURAL PRECAST CONCRETE WITH
CUSTOM ETCHED RELIEF PATTERN, TO BE
MOUNTED DIRECTLY TO STRUCTURAL PRECAST,
WITH 1" AIRSPACE, SEE ARCHITECTURAL
SECTIONS.
3 PRECAST CONCRETE PANELS WITH TEXTURED
COATING
4 ALUMINUM CURTAIN WALL SYSTEM WINDOWS AT
STAIRS OF PARKING GARAGE
5 CAST-IN-PLACE CONCRETE WITH TEXTURED
COATING
6 ALUMINUM MESH SYSTEM WITH ALUMINUM
FRAME BETWEEN PRECAST CONCRETE
MEMBERS, SUICIDE FALL PREVENTION SYSTEM.
7 EXTERIOR SIGNAGE ON STRUCTURAL PRECAST
PANELS. THE VA EMBLEM ON STRUCTURAL
PRECAST SHALL BE INSTALLED USING A FORM
LINER ON THE PRECAST. OTHER SIGNAGE ON THE
ARCHITECTURAL PRECAST SHALL BE INSTALLED
USING A FORM LINER ON THE ARCHITECTURAL
PRECAST PANELS.
8 CONCRETE COLUMNS WITH TEXTURED FINISH
9 CMU INFILL WITH TEXTURED FINISH
10 CONSTRUCTION/CONTRACTION JOINTS IN
CONCRETE FOUNDATION WALL, SEE STRUCTURAL
DRAWINGS FOR EXACT LOCATION , JOINT TYPE
AND DETAILS
11 NEW LIGHT FIXTURES, SEE ELECTRICAL
DRAWINGS FOR TYPE AND SIZES.
12 EXIT SIGNS LOCATED ABOVE DOOR TO EGRESS
STAIR.
13 FIRE ALARM STROBE.
14 FIRE ALARM PULL STATION.
15 CMU INFILL WALL FOR STAIR AND ELEVATOR
ENCLOSURES
16 CONTINUOUS METAL REGLET INSET INTO
PRECAST, PROVIDE FORMER SLOT INTO
PRECAST, WITH CONTINUOUS FLASHING, SEAL
ALL OPENINGS / END PIECES INTO WALL.
17 CONTINUOUS METAL SILL FLASHING AT CURTAIN
WALL TO BE CONNECTED AND SEALED TO
REGLET / FLASHING AT PRECAST TRANSITION.
PROVIDE SEALANT AT ALL CONNECTIONS.
18 PROVIDE CONTINUOUS VERTICLE CONTROL JOINT
IN BRICK MASONRY AS INDICATED. PROVIDE 3/8"
APPROXIMATE CONTROL JOINT WITH
CONTINUOUS SEALANT AND BACKER ROD.
SEALANT TO MATCH MORTAR COLOR.
19 METAL COPING CAP, SEE DETAIL 1/AS501
20 CONCRETE COLUMNS
21 CONTROL JOINT IN TEXTURED FINISH
A. SEE CIVIL DRAWINGS FOR ALL ELEVATIONS AT
GRADE AROUND THE PARKING STRUCTURE.
B. SEE STRUCTURAL DRAWINGS FOR ALL
ELEVATIONS AT ALL DECK LEVELS INSIDE THE
PARKING STRUCTURE.
C. CONTRACTOR SHALL COORDINATE THE PRECAST
MEMBER AND THE CURTAIN WALL SYSTEMS
WHERE THE TWO CONNECT INSIDE STAIRS TO
ENSURE THE SIZES AND CONNECTIONS WORK
FOR BOTH SYSTEMS.
N
SCOPE OF WORK
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
LEVEL 2 SW STAIR
11' - 4"
FUTURE LEVEL 3
22' - 8"
ROOF
25' - 8"
LOWER LEVEL
-4' - 0"
1 2 3 4 5 6 7 8
AE302
AE302
AE302
AE302
LEVEL 01 NE STAIR
-1' - 2"
5.2
LEVEL 02 NE STAIR
11' - 7"
AE304
1.6
LEVEL 1
0"
3.9 8.85.54.5 6.5 7.5
AE304
_____2
AE303
FUTURE LEVEL 3
22' - 8"
ROOF
25' - 8"
LOWER LEVEL
-4' - 0"
1 2 3 4 5 6 7 8
AE302
AE302
AE302
AE302
AE303
LEVEL 01 NE STAIR
-1' - 2"
5.2
LEVEL 02 NE STAIR
11' - 7"
AE304
1.6
LEVEL 1
0"
3.9 8.85.54.5 6.5 7.5
3 3
AE304
AE303
ELEC
LEVEL 2 SW STAIR
11' - 4"
FUTURE LEVEL 3
22' - 8"
ROOF
25' - 8"
LOWER LEVEL
-4' - 0"
1 2 3 4 5 6 7 8
AE302
AE302
AE302
AE302
LEVEL 01 NE STAIR
-1' - 2"
5.2
LEVEL 02 NE STAIR
11' - 7"
AE304
1.6
LEVEL 1
0"
3.9 8.85.54.5 6.5 7.5
AE304
AE303
W2
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:1
:4
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AE301
SECTIONS
11 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
TM
Scale: 3/32" = 1'-0"
LONGITUDINAL SECTION - EAST BAY
Scale: 3/32" = 1'-0"
LONGITUDINAL SECTION - CENTER BAY
Scale: 3/32" = 1'-0"
LONGITUDINAL SECTION - WEST BAY
N
SCOPE OF WORK
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
A. SEE CIVIL DRAWINGS FOR ALL ELEVATIONS A7
GRADE AROUND THE PARKING STRUCTURE.
B. SEE STRUCTURAL DRAWINGS FOR ALL
ELEVATIONS AT DECK LEVELS INSIDE THE
PARKING STRUCTURE.
C. SEE ELECTRICAL DRAWINGS FOR ALL EQUIPMENT
LOCATED IN THE ELECTRICAL SPACES INSIDE
PARKING STRUCTURE
D. SEE TECHNOLOGY DRAWINGS FOR I.T EQUIPMENT
AND REQUIREMENTS LOCATED IN THE I.T AND
SECURITY SPACES INSIDE PARKING STRUCTURE.
E. SEE MECHANICAL DRAWINGS FOR MECHANICAL
EQUIPMENT LOCATION AND REQUIREMENTS
LOCATED INSIDE PARKING STRUCTURE.
F. SEE ARCHITECTURAL WATERPROOFING
DRAWINGS (AW) FOR WATERPROOFING
REQUIREMENTS OF ALL CONCRETE AGAINST SOIL
/ GRADE.
1 PRECAST CONCRETE LONG SPAN STRUCTURAL
SYSTEM, SEE STRUCTURAL DRAWINGS.
2 ALUMINUIM MESH SYSTEM BETWEEN PRECAST
CONCRETE MEMBERS. SUCIDE/FALL PREVENTION
SYSTEM.
3 ENCLOSURE SCREENING FOR OPENINGS IN
INTERIOR PRECAST UNITS TO BE INSTALLED +
SUGGESTED BY PRECAST SUPPLIER, SYSTEM TO
WORK WITH THEIR PRECAST PANELS.
ROOF
25' - 8"
C
LOWER LEVEL
-4' - 0"
D E G
AE301
AE301
AE301
AE301
AE301
AE301
140 SF
IT
262 SF
ELEC
118 SF
SEC
B F
LEVEL 02 NE STAIR
11' - 7"
LEVEL 1
0"
B.6
333 22
OPEN BEYOND
OPEN BEYOND
LEVEL 1 SW STAIR
0"
LEVEL 2 SW STAIR
11' - 4"
FUTURE LEVEL 3
22' - 8"
ROOF
25' - 8"
C D E G
AE301
AE301
AE301
AE301
AE301
AE301
56'-0"61'-6"56'-0"
ELEV
E2
ELEV
LOBBY
AE303
BA F
LEVEL 1
0"
TOP OF BEAM
17' - 0"
B.6
33 22
OPEN BEYOND OPEN BEYOND
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:1
:4
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AE302
SECTIONS
12 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
TM
Scale: 3/32" = 1'-0"
TRANSVERSE SECTION
Scale: 3/32" = 1'-0"
TRANSVERSE SECTION THROUGH ELEVATOR BANK
1 PRECAST CONCRETE LONG SPAN STRUCTURAL
SYSTEM, SEE STRUCTURAL DRAWINGS.
2 ALUMINUIM MESH SYSTEM BETWEEN PRECAST
CONCRETE MEMBERS. SUCIDE/FALL PREVENTION
SYSTEM.
3 CAST IN PLACE CONCRETE SHEAR WALLS.
4 STANDING SEAM METAL ROOF SYSTEM OVER
STEEL STRUCTURE SEE DETAIL XX/AEXX.
5 ELEVATOR SHAFT AT SOUTHEAST CORNER OF
PARKING STRUCTURE.
6 EGRESS STAIR ENCLOSURE AT THE NORTHEAST
CORNER OF PARKING STRUCTURAL.
7 CAST IN PLACE RETAINING WALL AT EAST SIDE OF
PARKING STRUCTURE.
8 AUXILIARY SPACES FOR IT, SECURITY LOCATED
INSIDE PARKING STRUCTURAL SEE AE101 FOR
EXACT LOCATION.
9 PRECAST CONCRETE PANELS, SEE STRUCTURAL
DRAWINGS.
10 8" CMU INFILL BETWEEN P.C STRUCTURAL
MEMBERS, SEE STRUCTURAL DRAWINGS P.C.
MEMBERS.
A. SEE CIVIL DRAWINGS FOR ALL ELEVATIONS A7
GRADE AROUND THE PARKING STRUCTURE.
B. SEE STRUCTURAL DRAWINGS FOR ALL
ELEVATIONS AT DECK LEVELS INSITE THE
PARKING STRUCTURE.
C. SEE ELECTRICAL DRAWINGS FOR ALL EQUIPMENT
LOCATED IN THE ELECTRICAL SPACES INSIDE
PARKING STRUCTURE
D. SEE TECHNOLOGY DRAWINGS FOR I.T EQUIPMENT
AND REQUIREMENTS LOCATED IN THE I.T AND
SECURITY SPACES INSIDE PARKING STRUCTURE.
E. SEE MECHANICAL DRAWINGS FOR MECHANICAL
EQUIPMENT LOCATION AND REQUIREMENTS
LOCATED INSIDE PARKING STRUCTURE.
F. SEE ARCHITECTURAL WATERPROOFING
DRAWINGS (AW) FOR WATERPROOFING
REQUIREMENTS OF ALL CONCRETE AGAINST SOIL
/ GRADE.
N
SCOPE OF WORK
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
PRECAST FLOOR
STRUCTURE, SEE
STRUCTURAL
DRAWINGS
PRECAST CONCRETE
WALL. SEE STRUCTURAL
DRAWINGS
FALL PROTECTION
ALUMINUM FRAME AND
MESH SECURED TO
PRECAST AND COLUMNS
FALL PROTECTION
ALUMINUM FRAME AND
MESH SECURED TO
PRECAST AND COLUMNS
PRECAST CONCRETE
COLUMN
BITUMINOUS DAMP
PROOFING ON C.I.P
FOUNDATION
WALL BELOW GRADE
LEVEL 2
VARIES
LEVEL 1
VARIES
ROOF
25' - 8"
A
LEVEL 02 NE STAIR
11' - 7"
SLOPE: 1/4"
CONCRETE FIBER
CANT STRIP
EXTERIOR
SIGNAGE
AE501
LEVEL 1
0"
TOP OF BEAM
17' - 0"
AE501
FOUNDATION
SEE STRUCTURAL
DRAWINGS
C.I.P FOUNDATION
WALL, SEE
STRUCTURAL
DRAWINGS
METAL COPING
AE501
BRICK MASONRY
WITH CONT.
WATER PROOFING
MEMBRANE ON
STRUCTURAL P.C.
ARCHITECTURAL
PRECAST PANEL
SECURED TO
STRUCTURAL P.C.
EXTERIOR
SIGNAGE
EXTENDS OUT
1" FROM PANEL
STRUCTURAL
PRECAST SANDWICH
PANEL, MIN R-13
INSULATION REQUIRED
BITUMINOUS DAMP
PROOFING ON C.I.P
FOUNDATION
WALL BELOW GRADE
BRICK MASONRY
WITH CONT.
WATER PROOFING
MEMBRANE ON
STRUCTURAL P.C.
PRECAST CONCRETE
FLOOR SLAB, SEE
STURCTURAL DRAWINGS
DRIP EDGE
FLASHING
ROOF
25' - 8"
A
DRIP EDGE FLASHING
MORTAR NET
SLOPE: 1/4"
FOUNDATION
SEE STRUCTURAL
DRAWINGS
C.I.P FOUNDATION
WALL, SEE
STRUCTURAL
DRAWINGS
STRUCTURAL
PRECAST WALL
BRICK TIE EVERY
@ 16" O.C.
AE501
BRICK MASONRY WITH
CONT. WATER
PROOFING MEMBRANE
ON STRUCTURAL P.C.
ALLUMINUM
CURTAIN WALL
SYSTEM
LEVEL 1
0"
EXTERIOR SIGNAGE
EXTENDS OUT 1"
FROM PANEL
PRECAST CONCRETE
FLOOR SLAB, SEE
STURCTURAL DRAWINGS
BITUMINOUS DAMP
PROOFING ON C.I.P
FOUNDATION
WALL BELOW GRADE
METAL COPING
STAIR LANDING
5' - 9 1/2"
WATER STOP FORMED
INTO CONCRETE
AE501
ARCHITECTURAL
P.C. PANEL
A
LEVEL 02 NE STAIR
11' - 7"
LEVEL 1
0"
TOP OF BEAM
17' - 0"
BITUMINOUS DAMP
PROOFING ON C.I.P
FOUNDATION
WALL BELOW GRADE
METAL COPING
CAP ON P.C.
EXTERIOR SIGNAGE
EXTEND OUT 1"
FROM PANEL
STRUCTURAL
PRECAST SANDWICH
PANEL, MIN R-13
INSULATION REQUIRED
BRICK MASONRY WITH
CONT. WATER
PROOFING MEMBRANE
ON STRUCTURAL P.C.
ARCHITECTURAL
PRECAST PANEL
SECURED TO
STRUCTURAL P.C.
DRIP EDGE
FLASHING
AE501
ROOF
25' - 8"
ROOF
25' - 8"
1.6
LEVEL 1
0"
TOP OF BEAM
17' - 0"
SLOPE: 1/4"
PRECAST CONCRETE
BEAM FOR FUTURE LANDING,
SEE STRUCTURAL DRAWINGS
PRECAST CONCRETE
COLUMN BEYOND
PRECAST CONCRETE
BEAM AT LANDING,
SEE STRUCTURAL DRAWINGS
CURTAIN WALL SPANDREL AT
CONCRETE BEAM
ALUMINUM CURTAIN
WALL SYSTEM
CURTAIN WALL SPANDREL AT
CONCRETE BEAM
FOUNDATION
SEE STRUCTURAL
DRAWINGS
BITUMINOUS DAMP
PROOFING ON C.I.P
FOUNDATION
WALL BELOW GRADE
PRECAST STAIR LANDING, SEE
STURCTURAL DRAWINGS
PRECAST CONCRETE
SPANDREL, SEE
STRUCTURAL DRAWINGS
PRECAST CONCRETE FLOOR
SLAB, SEE STURCTURAL
DRAWINGS
CONCRETE FOUNDATION,
SEE STRUCTURAL
DRAWINGS
METAL COPING
AE501
AE501
AE501
SILL FLASHING
STAIR LANDING
5' - 9 1/2"
WATER STOP FORMED
INTO CONCRETE
AE501
SIM
STEEL HAND/GUARD RAIL,
ATTACHED TO CONCRETE
COLUMNS ON EACH SIDE
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:1
:4
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AE303
WALL SECTIONS
13 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
TM
Scale: 1/2" = 1'-0"
WALL SECTION - NORTH
CENTRAL BAY
Scale: 1/2" = 1'-0"
WALL SECTION THRU SW ELEVATOR BANK
Scale: 1/2" = 1'-0"
WALL SECTION THRU SW STAIR CURTAIN WALL AND
PRECAST PANEL
Scale: 1/2" = 1'-0"
WALL SECTION THRU ELEVATOR EQUIPMENT ROOM
Scale: 1/2" = 1'-0"
WALL SECTION THRU SW-STAIR CURTAIN WALL SYSTEM
ROOF
25' - 8"
C
CAST IN PLACE
CONCRETE WALL, SEE
STRUCTURAL
DARWINGS
STANDING SEAM METAL
ROOF ON METAL DECK,
SEE STRUCTURAL
DRAWINGS
GALV. METAL GUTTER
ATTACHED TO BENT
PLATE, MATCH SSMR
FINISH
B.6
PRECAST CONCRETE
SPANDREL/BEAM
PRECAST
CONCRETE TWIN
TEE
LEVEL 1
0' - 0"
AE702
FALL PROTECTION
ALUMINUM FRAME
AND MESH SECURED
TO PRECAST PANEL
AND COLUMNS
C
LOWER LEVEL
-4' - 0"
LEVEL 02 NE STAIR
11' - 7"
B.6
PRECAST CONCRETE
SPANDREL/BEAM
PRECAST
CONCRETE TWIN
TEE WITH TOPPING
SLAB, SEE
STRUCTURAL
DRAWINGS
CAST IN PLACE
CONCRETE WALL, SEE
STRUCTURAL
DARWINGS
STANDING SEAM METAL
ROOF ON METAL DECK,
SEE STRUCTURAL
DRAWINGS
GALV. METAL GUTTER
ATTACHED TO BENT
PLATE, MATCH SSMR
FINISH
CAST IN PLACE
CONCRETE COLUMN
AE501
AE501
LEVEL 1
0' - 0"
FALL PROTECTION
ALUMINUM FRAME
AND MESH SECURED
TO PRECAST PANEL
AND COLUMNS
STEEL BEAMS,
SEE STRUCTURAL
DRAWINGS
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:1
:4
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AE304
WALL SECTIONS
14 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
TM
Scale: 1/2" = 1'-0"
COVERED WALK ROOF - SECTION 01
A. SEE STRUCTURAL DRAWINGS FOR ALL STEEL
FRAMING MEMBER FOR COVERED WALK ROOF
ASSEMBLY.
B. SEE CIVIL DRAWINGS FOR FINISH GRADE
ELEVATIONS AROUND GARAGE STRUCTURE.
C. SEE STRUCTURAL DRAWINGS FOR SLAB
ELEVATIONS INSIDE GARAGE STRUCTURE.
N
SCOPE OF WORK
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
Scale: 1/2" = 1'-0"
COVERED WALK ROOF - SECTION
C
1 2 3 4
AE701
AE302
AE302
RAMP DOWN
SLOPE = 1:20
RAMP DOWN
SLOPE = 1:20
40'-1 1/2"7'-0"40'-0"
STAIRS DOWN
8 TREADS, 9 RISERS
AE401
AE202
1_____
AE303
SLOPE CONCRETE2
B
A
AE304
15'-11 1/2" 12'-0" 16'-0" 12'-0" 16'-0" 7'-0 1/2" 11"
1.6 3.9
B.6
14'-6" 2'-0"
6 5 6 6 65 5
ELEV
E1
ELEV
E2
S1.1 100 101
204 SF
ELEV
EQUIP
82 SF
MECH
STAIR
S1
AE303
AE303
AE701
LEVEL 2 SW STAIR
11' - 4"
FUTURE LEVEL 3
22' - 8"
ROOF
25' - 8"
LOWER LEVEL
-4' - 0"
1 2 3
AE302
AE303
LEVEL 01 NE STAIR
-1' - 2"
LEVEL 02 NE STAIR
11' - 7"
AE304
1.6
LEVEL 1
0"
AE303
W2
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
/1
/2
:1
:4
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AE401
ENLARGED PLANS AND SECTIONS
15 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
TM
N
SCOPE OF WORK
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
Scale: 1/4" = 1'-0"
ENLARGED PLAN - ACCESSIBLE RAMP
Scale: 1/4" = 1'-0"
SECTION AT EXTERIOR RAMP
1 STOREFRONT WINDOW AND DOOR AROUND
ELEVATOR LOBBY AT SECOND LEVEL OF PARKING
STRUCTURE.
2 SLOPE CONCRETE WALL DOWN EVENLY WITH THE
ADA RAMP AT 4'-0" ABOVE RAMP AS INDICATED,
SEE DETAIL 6/AE702
3 ALUMINUM MESH SYSTEM WITH ALUMINUM FRAME
BETWEEN PRECAST CONCRETE MEMBERS,
SUICIDE/FALL PREVENTION SYSTEM.
4 ELEVATOR SHAFT FOR FUTURE ELEVATOR.
5 ARCHITECTURAL PRECAST ATTACHED TO
STRUCTURAL PRECAST PANEL.
6 BRICK MASONRY VENEER AGAINST STRUCTURAL
PRECAST PANEL.
7 EXPOSED STRUCTURE WITH TEXTURED FINISH.
8 CONCRETE ADA RAMP ON GRADE, SLOPED AS
INDICATED DOWN TO GRADE, SEE STRUCTURAL
DRAWINGS.
9 ELEVATOR PIT LADDER SEE SPECIFICATION
SECTION 05 50 00, EXTEND LADDER LIP 48" ABOVE
ELEVATOR LOBBY FIRST LEVEL.
10 ELEVATOR SUMP PUMP PIT, SEE INSTALLED
EQUIPMENT FOR REQUIRED SIZING.
11 PARAPET OF ROOF BEYOND
N O
R T
H0 2 4 8
A. SEE STRUCTURAL DRAWINGS FOR ALL STEEL
FRAMING MEMBER FOR COVERED WALK ROOF
ASSEMBLY.
B. SEE CIVIL DRAWINGS FOR FINISH GRADE
ELEVATIONS AROUND GARAGE STRUCTURE.
C. SEE STRUCTURAL DRAWINGS FOR SLAB
ELEVATIONS INSIDE GARAGE STRUCTURE.
D. SEE ARCHITECTURAL WATERPROOFING
DRAWINGS (AW) FOR WATERPROOFING
REQUIREMENTS OF ALL CONCRETE AGAINST
SOIL / GRADE.
D
E
140 SF
IT
262 SF
ELEC
118 SF
SEC
AE301
_____2
AE301
AE302
AE302
6'-0"10'-0"
5.5
D
E
AE301
_____2
AE301
AE302
AE302
5.5
IT
ELEC
SEC
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
/1
/2
:1
:4
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AE402
ENLARGED PLANS
16 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS
635-41419-292
N/A
TM
Scale: 1/4" = 1'-0"
ENLARGED PLAN
N O
R T
H0 2 4 8
A. SEE STRUCTURAL DRAWINGS FOR ALL STEEL
FRAMING MEMBER FOR COVERED WALK ROOF
ASSEMBLY.
B. SEE CIVIL DRAWINGS FOR FINISH GRADE
ELEVATIONS AROUND GARAGE STRUCTURE.
C. SEE STRUCTURAL DRAWINGS FOR SLAB
ELEVATIONS INSIDE GARAGE STRUCTURE.
D. SEE ELECTRICAL DRAWINGS FOR EQUIPMENT
REQUIREMENTS IN SPACES INDICATED.
E. SEE MECHANICAL DRAWINGS FOR HVAC
REQUIREMENTS IN SPACES INDICATED.
F. SEE ARCHITECTURAL WATERPROOFING
DRAWINGS (AW) FOR WATERPROOFING
REQUIREMENTS OF ALL CONCRETE AGAINST
SOIL / GRADE.
N
SCOPE OF WORK
KEY PLAN
SCALE: NO SCALE
AREA OF WORK
Scale: 1/4" = 1'-0"
ENLARGED REFLECTED CEILING PLAN
N O
R T
H0 2 4 8
1 PROVIDE 3 5/8" METAL STUD FRAMING WITH 4"
BATT INSULATION AND 5/8" MOISTURE RESISTANT
GYP. BOARD, TAPPED AND FINISHED UP TO
STRUCTURE ABOVE ON ONE SIDE(ALL WALLS)
2 NEW LIGHT FIXTURES, SEE ELECTRICAL
DRAWINGS FOR TYPE AND SIZES.
3 PRECAST CONCRETE STRUCTURAL SYSTEM, SEE
STRUCTURAL DRAWINGS.
4 PRECAST CONCRETE STRUCTURAL WALL PANELS,
SEE STRUCTURAL DRAWINGS.
5 8" CMU INFILL BETWEEN P.C STRUCTURAL
MEMBERS, SEE STRUCTURAL DRAWINGS P.C.
MEMBERS.
ROOF
25' - 8"
TPO ROOF
MEMBRANESLOPE: 1/4"
ALUMINUM CURTAIN
WALL SYSTEM
TAPERED RIGID INSULATION
MIN R-25
CONT. FIBER
CANT STRIP
WOOD BLOCKING
ATTACHED TO
PRECAST
CONCRETE ROOF PLANK
SLAB SEE STRUCTURAL
DRAWINGS
STRUCTURAL PRECAST
CONCRETE WALL PANEL
METAL COPING CAP
W/CONT. CLEAT,
MATCH CURTAIN WALL
COLOR AND FINISH
1.6
CONTINUOUS SEALANT
WITH BACKER ROD
P.T./F.T. WOOD SHIM
CONTINUOUS
METAL FLASHING
P.C CONCRETE
COLUMN - SEE
STRUCTRUAL DWGS
CONT. SEALANT
W/BACKER ROD
ALUMINUM CURTAIN
WALL SYSTEM
STRUCTURAL PRECAST
PANEL
CONT. 1" AIR
SPACE BETWEEN
STRUCT.
PRECAST AND
FACE BRICK
BRICK MASONRY
1.6
CONT. SHEET
WATER PROOFING
ON STRUCT. P.C
TEXTURED FINISH
A
STRUCTURAL
PRECAST PANEL SEE
STRUCTURAL
DRAWINGSBRICK MASONRY
W/1" AIR SPACE
AND CONT. SHEET
WATER PROOFING
C..I.P CONCRETE
FOUNDATION WALL
ARCHITECTURAL
PRE CAST
LEVEL 1
0"
METAL FLASHING
W/ CONT.
SEALANT
CONT. METAL
FLASHING
A
CONT. SHEET WATER
PROOFING
STRUCTURAL PRECAST
PANEL SEE STRUCTURAL
DRAWINGS
CONT. METAL SILL
FLASHING PER
CURTAIN WALL
MANUFACTURER
ALUMINUM CURTAIN
WALL SYSTEM
BRICK MASONRY
WITH 1" AIR SPACE
CONT. SEALANT AT
EDGE OF SILL
FLASHING
P.T./F.T. WOOD SHIM
SEALANT W/ BACKER ROD
A
LEVEL 02 NE STAIR
11' - 7"
CONT. 1" AIR SPACE W/
CONT. SHEET WATER
PROOFING
STRUCTURAL PRECAST
PANEL W/TEXTURE
FINISH.
BRICK MASONRY W/
WALL TIES TO PANEL @
16" O.C.
FLASHING SHEET
ATTACHED TO
PRECAST
SHELF ANGLE, SEE
STRUCTURAL
DRAWINGS.
METAL FLASHING
ATTACHED TO PRECAST
PANEL W/ CONT. SEALANT
BOTTOM EDGE
ARCHITECTURAL
PRE CAST PANEL
ATTACHED TO
STRUCTURALLY P.C.
CONT. SHEET WATER
PROOFING
METAL FLASHING W CONT
SEALANT BOTTOM EDGE
CONT. KEY GROVE FORMED IN
PRECAST TO INSTALL REGLET,
FILL W/ SEALANT AFTER
REGLET INSTALLED
1.6
ALUMINUM CURTAIN
WALL SYSTEM
PRECAST CONCRETE
BEAM, SEE STRUCTURAL
DRAWINGS
CURTAIN WALL
SPANDREL
STEEL ANGLE
ATTACHED TO P.C.
BEAM AND CURTAIN
WALL SYSTEM
1.6
CONCRETE
FOUNDATION WALL,
SEE STRUCTURAL
DRAWINGS
ALUMINUM CURTAIN
WALL SYSTEM
LEVEL 1 SLAB
CONT. METAL SILL
FLASHING PER
CURTAIN WALL
MANUFACTURER'S
P.T./F.T. WOOD SHIM
SEALANT W/
BACKER ROD
SEALANT
B.6B.6B.6B.6
STANDING SEAM
METAL ROOF
ROOF
FASTENERS
BENT PLATE, SEE
STRUCTURAL
DRAWINGS
GALV METAL
GUTTER
CAULKING
VAPOR
BARRIER
STRUCTURAL
METAL DECK
FLASHING
CC
LEVEL 02 NE STAIR
11' - 7"
LEVEL 2 SLAB
STRUCTURAL
PRECAST PANEL
STRUCTURAL INBED
CONNECTION POINTS, SEE
STURCTURAL DRAWINGS
STANDING SEAM
METAL ROOF
STRUCTURAL METAL
DECK
BRACING FOR I
BEAM
STRUCTURAL I BEAM
SEALANT
METAL REGLET WITH
CONTINUOUS KEY
SLOT IN PRECAST
PANEL
4" TALL CONTINUOUS
METAL FLASHING
FULL ADHERED MEMBRANE
FLASHING SHEET
A
METAL COPING CAP W/
CONTINUOUS CLEATS,
MATCH CURTAIN WALL
COLOR
CONTINUOUS
SHEET
WATERPROOFING
BRICK MASONRY W/
WALL TIES TO
STRUCTURAL P.C.
PANEL
ARCHITECTURAL
P.C. PANEL
STRUCTURAL P.C.
PANEL
BASE FLASHING
MEMBRANE UP OVER
TOP OF WALL
CONTINUOUS FIBER
CANT STRIP
TPO ROOF MEMRANE
OVER RIGID
INSULATION (MIN R-25)
CONCRETE
ROOF SLAB
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:1
:5
P
M C
U s e rs
\g g o n z a le s \D o c u m e n ts \A
-2
-O
K C
P a rk in g G a ra g e g g o n z a le s B
W J C
U .r v t
AE501
DETAILS
17 20AT
PARKING GARAGE 2
921 NE 13TH STREET
OKLAHOMA CITY, OK 73104
July 8, 2022
100% CONSTRUCTION DOCUMENTS