This document is an Asbestos Inspection Report for the Cahuilla Ranger Station located at 4500 Gecko Rd. in Brawley, California, prepared by Nicklaus Engineering, Inc. on behalf of North Wind Construction Services. The inspection involved collecting and analyzing 18 samples from various areas including the office, bunker house, base cove, flooring, insulation, and roof materials. Laboratory analysis by SGS Laboratories using Polarized Light Microscopy (PLM) determined that no Asbestos Containing Material (ACM) was detected in any of the samples. The inspection was conducted in accordance with ASTM Standard E 2356-14 and followed standard procedures including site inspection, sample collection, preparation, and analytical review.
View the file
Other files for this federal contract opportunity
Show all 26
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5740 Arville Street, Suite 209 | Las Vegas, NV. 89118 | 702-547-6186 | www.northwindgrp.com
3/13/2023
Peter Graves Contract No: L17PC00072 Bureau of Land Management Task Order No: 140L122F0011 AML/Hazmat Program Lead NWCS Project No: 040111.500.26.25 California State Office p15graves@blm.gov 916-978-4685
SUBJECT: ASBESTOS INSPECTION, SAMPLING AND, ANALYSIS REPORT FOR THE CAHUILLA RANGER
STATION, BRAWLEY, CALIFORNIA
Dear Mr. Graves, North Wind Construction Services (NWCS) has completed the asbestos inspection and sampling for the subject site. The site is identified as the Cahuilla Ranger Station, near Brawley, California. The project summary is below and supporting documentation can be found in the Enclosures.
Project Summary
Asbestos containing material (ACM) inspection, sampling, and analysis:
• NWCS sub-contracted Nicklaus Engineering Inc. (Nicklaus) for the ACM inspection services.
• Nicklaus mobilized to the site and completed the inspection and sampling activities on February 27, 2023.
• A total of 18 samples were collected and submitted to SGS Laboratories for asbestos analysis by
Polarized Light Microscopy (PLM).
• All samples returned results of non-detect (ND) for asbestos.
If you have any questions, please do not hesitate to contact me at (505-634-8301) or felipe.aragon@northwindgrp.com .
Sincerely, Felipe Aragon
Enclosures: Nicklaus Asbestos Inspection Report cc: Kevin Redmond, NWCS (via email) mailto:p15graves@blm.gov mailto:felipe.aragon@northwindgrp.com
5740 Arville Street, Suite 209 | Las Vegas, NV. 89118 | 702-547-6186 | www.northwindgrp.com
ENCLOSURES
NICKLAUS ASBESTOS INSPECTION REPORT
Asbestos Inspection Report
BLM Cahuilla Ranger Station
4500 Gecko Rd.
Brawley, CA 92227
Prepared for:
Felipe Aragon
North Wind Construction Services
Cell: 505-634-8301 felipe.aragon@northwindgrp.com
Submitted by:
Nicklaus Engineering Inc.
1851 W. 24th Street
Yuma, AZ 85364
NEI Project 023-0041.00000 mailto:felipe.aragon@northwindgrp.com
Table of Contents
1.0 ACRONYMS AND ABBREVIATIONS
2.0 EXECUTIVE SUMMARY
3.0 PROJECT LIMITATIONS
4.0 INSPECTION PROCEDURES
5.0 ANALYTICAL RESULTS
6.0 QUALITATIVE ASSESSMENT OF ACM
7.0 QUALIFICATIONS
8.0 LIST OF ATTACHMENTS
Attachment 1 – Analytical Results
Attachment 2 – Inspector Certifications
1.0 ACRONYMS AND ABBREVIATIONS
AC Air Conditioning
ACM Asbestos Containing Material
AHERA Asbestos Hazard Emergency Response Act of 1986
ASTM American Society for Testing and Materials
EPA Environmental Protection Agency
HVAC Heating Ventilating and Air Condition
NEI Nicklaus Engineering, Inc.
NESHAP National Emissions Standard for Hazardous Air Pollutants
NIST National Institute of Standards and Technology
NVLAP National Voluntary Laboratory Accreditation Program
OSHA Occupational Safety and Health Administration
PLM Polarized Light Microscopy
RACM Regulated Asbestos Containing Material
SF Square Feet
2.0 EXECUTIVE SUMMARY
Nicklaus Engineering has performed this asbestos inspection of a wall located at the
Cahuilla Ranger Station (Bunker House and office insulation) located at 4500 Gecko
Rd. in Brawley, CA. This inspection included:
• Site Inspection
• Sample Preparation
• Sample Collection
• Laboratory Analysis
• Analytical Review
• Final Report Preparation
Based upon the information obtained during the asbestos inspection, considering the limitations contained within Section 3.0, this asbestos inspection has revealed
No Asbestos Containing Material (ACM).
3.0 PROJECT LIMITATIONS
The asbestos inspection was conducted in accordance with ASTM Standard E 2356-
14, the Standard Practice for Comprehensive Building Asbestos Surveys. The intent of this standard is to provide procedures for conducting comprehensive surveys of buildings and facilities for the purpose of locating, identifying, quantifying, and assessing asbestos containing materials. This project was limited to sampling in the following areas:
• Insulation in Office
• Bunker Location
4.0 INSPECTION PROCEDURES
4.1 Sample Inventory
All homogeneous areas of suspect materials were listed during the initial building inspection. The samples are itemized in Table 1 below.
Table 1
Summary of samples collected
ID Name Location Date
1 Insulation - Office Office/throughout 2/27/23
2 Insulation - Office Office/throughout 2/27/23
3 Insulation - Office Office/throughout 2/27/23
4 Base Cove -Bunker Bunker - throughout lower wall 2/27/23
5 Base Cove -Bunker Bunker - throughout lower wall 2/27/23
6 Base Cove -Bunker Bunker - throughout lower wall 2/27/23
7 Flooring -Bunker Bunker/throughout 2/27/23
8 Flooring -Bunker Bunker/throughout 2/27/23
9 Flooring -Bunker Bunker/throughout 2/27/23
10 Insulation -Bunker Bunker/throughout 2/27/23
11 Insulation -Bunker Bunker/throughout 2/27/23
12 Insulation -Bunker Bunker/throughout 2/27/23
13 Roof Material - Bunker Bunker/Roof 2/27/23
14 Roof Material - Bunker Bunker/Roof 2/27/23
15 Roof Material - Bunker Bunker/Roof 2/27/23
16 Roof Material - Bunker Bunker/Roof 2/27/23
17 Roof Material - Bunker Bunker/Roof 2/27/23
18 Roof Material - Bunker Bunker/Roof 2/27/23
4.2 Sample Analysis
Samples were sent to SGS Laboratories for analysis by Polarized Light Microscopy
(PLM) by EPA Method 600/R-93/116. Sample layers which are friable and estimated by the analyst to contain asbestos were point counted by the laboratory. Such point counting is required by NESHAP in order to rely on analytical results containing asbestos.
SGS Laboratories is a certified laboratory recognized by the National Voluntary
Laboratory Accreditation Program (NVLAP) administered by the United States
Department of Commerce National Institute of Standards and Technology.
5.0 ANALYTICAL RESULTS
The sample results have been included as Attachment 1 for reference. No ACM was detected.
6.0 QUALITATIVE ASSESSMENT
No Qualitative Assessment was necessary as no asbestos-containing material (ACM) was detected.
7.0 QUALIFICATIONS
7.1 Inspector Qualifications
The inspectors involved in this asbestos inspection are certified as AHERA
Asbestos Inspectors. Copies of the current asbestos certifications have been included as Attachment 2.
7.2 Laboratory Qualifications
The analytical laboratory is certified by the National Voluntary Laboratory
Accreditation Program (NVLAP) of the National Institute of Standards and
Technology (NIST) for the asbestos analyses conducted by the laboratory.
8.0 LIST OF ATTACHMENTS
Attachment 1 Analytical Results
Attachment 2 Inspector Certifications
Attachment 1
Analytical Results
Final Report
(EPA Method 40CFR, Part 763, Appendix E to Subpart E and EPA 600/R-93-116, Visual Area Estimation)
Bulk Asbestos Analysis NVLAP Lab Code: 101459-1
L2091Client ID:Nicklaus Engineering B344662Report Number:Coy Richards
Date Received:1851 W 24th St.
03/01/23Date Analyzed:Suite 101 03/01/23Date Printed:Yuma, AZ 85364
First Reported:
L2091Ranger Station, IC Court, City Hall in El Centro SGSFL Job ID:Job ID/Site:
Date(s) Collected: 02/27/2023
18Total Samples Submitted:
Total Samples Analyzed: 17
02/28/23
03/01/23
Sample ID Lab Number Asbestos
Type Percent in
Layer Asbestos AsbestosPercent in Percent in
Type TypeLayer Layer
1.Insulation-office 51641066
Layer: White Fibrous Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace) Fibrous Glass (99 %)
2.Insulation-office 51641067
Layer: White Fibrous Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace) Fibrous Glass (99 %)
3.Insulation-office 51641068
Layer: White Fibrous Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace) Fibrous Glass (99 %)
4.Base Cove-Bunker 51641069
Layer: Brown Non-Fibrous Material ND
Layer: Tan Mastic ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace)
5.Base Cove-Bunker 51641070
Layer: Brown Non-Fibrous Material ND
Layer: Tan Mastic ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace)
6.Base Cove-Bunker 51641071
Layer: Brown Non-Fibrous Material ND
Layer: Tan Mastic ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace)
7.Flooring Bunker 51641072
Layer: Beige Tile ND
Layer: Tan Mastic ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace)
Report Number: B344662
Date Printed: 03/01/23Client Name: Nicklaus Engineering
Sample ID Lab Number Asbestos
Type Percent in
Layer Asbestos AsbestosPercent in Percent in
Type TypeLayer Layer
8.Flooring Bunker 51641073
Layer: Beige Tile ND
Layer: Tan Mastic ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace)
9.Flooring Bunker 51641074
Layer: Beige Tile ND
Layer: Tan Mastic ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace)
10.Insulation Bunker 51641075
Layer: Pink Fibrous Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace) Fibrous Glass (99 %)
11.Insulation Bunker 51641076
Layer: Pink Fibrous Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace) Fibrous Glass (99 %)
13.Roof Material Bunker 51641078
Layer: Grey Roof Shingle ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace) Fibrous Glass (20 %)
14.Roof Material Bunker 51641079
Layer: Grey Roof Shingle ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace) Fibrous Glass (20 %)
15.Roof Material Bunker 51641080
Layer: Grey Roof Shingle ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace) Fibrous Glass (20 %)
16.Roof Material Bunker 51641081
Layer: Grey Roof Shingle ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace) Fibrous Glass (20 %)
17.Roof Material Bunker 51641082
Layer: Grey Roof Shingle ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace) Fibrous Glass (20 %)
18.Roof Material Bunker 51641083
Layer: Grey Roof Shingle ND
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (Trace) Fibrous Glass (20 %)
Report Number: B344662
Date Printed: 03/01/23Client Name: Nicklaus Engineering
Sample ID Lab Number Asbestos
Type Percent in
Layer Asbestos AsbestosPercent in Percent in
Type TypeLayer Layer
Analytical results and reports are generated by SGS Forensic Laboratories (SGSFL) at the request of and for the exclusive use of the person or entity (client) named on such report.
Results, reports or copies of same will not be released by SGSFL to any third party without prior written request from client. This report applies only to the sample(s) tested.
Supporting laboratory documentation is available upon request. This report must not be reproduced except in full, unless approved by SGSFL. The client is solely responsible for the use and interpretation of test results and reports requested from SGSFL. SGSFL is not able to assess the degree of hazard resulting from materials analyzed. SGS Forensic
Laboratories reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. All samples were received in acceptable condition unless otherwise noted.
Note: Limit of Quantification ('LOQ') = 1%. 'Trace' denotes the presence of asbestos below the LOQ. 'ND' = 'None Detected'.
Tiffani Ludd, Laboratory Supervisor, Carson Laboratory
Attachment 2
Inspector Certifications
Coy Richards
March 23, 2022
ON-4644-1043-032322
23-Mar-2022
23-Mar-2023
Powered by TCPDF (www.tcpdf.org) http://www.tcpdf.org
Certificate of Training
This is to certify that
Stacy Gutierrez
Has successfully completed 4 hours of formal training entitled
AHERA Building Inspector Refresher as approved by the California Division of Occupational Safety and Health and as certified by the Environmental Protection Agency and approved by AHERA under TSCA Title II
Presented by:
Design For Health Training Center 2667 Camino del Rio South, Suite 207 San Diego, CA 92108 Phone: (619) 291-1777 Fax: (619) 291-4318
By:
Jorge A Valdez, B.S.
Director of Training
DOSH Approval #011-06 Certificate # 0722BIR190753 Course Date (s): 07/06/2022
Exam Date: NA
This is an annual certification. It must be renewed by : 07/06/2023