This document provides details for a federal contract opportunity with the Department of Veterans Affairs to construct social work consolidated clinic space. The solicitation number is 36C77622B0016 and seeks to construct clinic space at the VA medical center in Y1DB under project number VA-21-00019843. Offerors should provide pricing to complete construction drawings provided in Attachment 10 by April 4, 2022. The award date is unspecified but the opportunity is identified as a solicitation. The construction work requires consolidating existing social work space at the medical center into a new clinic area. No further specifics regarding products, services, or pricing are included in this document.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING LIST
BUILDING SUMMARY
PROJECT INFORMATION
Project Name: Design Social Work and Expand Clinical Space
Project Number: 612-163
Project Location: VA Northern California Health Care System - Mather, CA
Project Purpose/Use: VA Social Services and Outpatient Care
BUILDING AREA:
FIRST FLOOR 7,555.74 GSF
SECOND FLOOR 6,732.62 GSF
TOTAL 14,286 GSF (INCLUDING OUTSIDE STORAGE)
GENERAL NOTES
1. THESE DRAWINGS SHALL BE USED ONLY FOR THIS SPECIFIC PROJECT/SITE LOCATION. THESE DRAWINGS ARE A COMPOSITE SET OF CONTRACT DOCUMENTS AND SHALL NOT BE SEPARATED FOR DISTRIBUTION. THE GENERAL CONTRACTOR SHALL REVIEW ALL DRAWINGS AND PROVIDE/DISTRIBUTE THE ENTIRE SET TO EACH SUBCONTRACTOR FOR INTERDISCIPLINARY COORDINATION.
2. THE GENERAL CONTRACTOR SHALL VISIT THE SITE TO INSPECT EXISTING CONDITIONS AND VERIFY WORK BEING PERFORMED
BEFORE SUBMITTING COST QUOTATIONS FOR WORK.
3. NOTIFY THE ARCHITECT PROMPTLY OF ANY ERRORS, OMISSIONS, INCONSISTENCIES, DISCREPANCIES AND CONFLICTS WITHIN THE CONTRACT DOCUMENTS AND ITS ASSOCIATED FIELD/PROJECT CONDITIONS SO THAT A RESOLUTION CAN BE PROVIDED PRIOR TO
CONTINUING WITH WORK.
4. DO NOT SCALE THE DRAWINGS. REQUEST ANY MISSING DIMENSIONS FROM THE ARCHITECT
5. ALL WORK PERFORMED SHALL BE IN STRICT COMPLIANCE WITH GOVERNING FEDERAL BUILDING CODE REQUIREMENTS, SHALL BE EXECUTED IN ACCORDANCE WITH ACCEPTED INDUSTRY STANDARDS, AND SHALL CONFORM TO SPECIFIC REGULATIONS AS MANDATED BY THE OWNER, THE ARCHITECT, AND THE AUTHORITIES HAVING JURISDICTION. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ANY FEES ASSOCIATED WITH PROCURING SUCH PERMITS AND CERTIFICATES AND SHALL FURNISH COPIES OF
PERMITS, INSPECTIONS, AND CERTIFICATES TO THE OWNER.
6. THE GENERAL CONTRACTOR SHALL COORDINATE ALL WORK TO MINIMIZE DISRUPTION OF ANY EXISTING TENANTS OR BUILDING OPERATIONS (IF ANY). THE GENERAL CONTRACTOR SHALL TAKE ADEQUATE PRECAUTIONS TO PROTECT BUILDING OCCUPANTS, MATERIALS, AND EXISTING CONSTRUCTION THROUGHOUT ALL PHASES OF CONSTRUCTION. DAMAGE TO ANY NEW CONSTRUCTION OR
EQUIPMENT SHALL BE RESTORED TO ORIGINAL CONDITION AT THE CONTRACTOR'S EXPENSE.
7. THE GENERAL CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE JOB SITE ON A DAILY BASIS.
8. ANY REQUESTS FOR SUBSTITUTIONS OF ANY SPECIFIED ITEM ARE TO BE SUBMITTED TO THE VA COR IN WRITING AND WILL BE CONSIDERED ONLY IF THE ALTERNATE PROPOSED IS PROVEN TO BE ADVANTAGEOUS TO THE OWNER WITH RESPECT TO DELIVERY
DATE, QUALITY, OR COST, AND IF IT MEETS THE DESIGN INTENT.
9. THE MEANS AND METHODS OF CONSTRUCTION, AND TEMPORARY STRUCTURES AND FACILITIES, ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE ARCHITECT DOES NOT ASSUME ANY RESPONSIBILITY FOR THE CONTRACTOR'S MEANS AND METHODS OR
FOR TEMPORARY STRUCTURES.
10. DEMOLITION OF EXISTING STRUCTURE(S) IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE CONTRACTOR SHALL
EMPLOY ENGINEERING EXPERTISE AS NEEDED TO ASSIST IN DEMOLITION.
11. JOB SITE SAFETY AND SECURITY ARE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR SHALL CONSULT WITH LOCAL FIRE AUTHORITIES TO ASCERTAIN REQUIREMENTS FOR FIRE SUPPRESSION AND SAFETY DURING CONSTRUCTION. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR MEETING OSHA REGULATIONS DURING CONSTRUCTION.
12. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR STORAGE AND PROTECTION OF BUILDING MATERIALS, AND INSTALLED CONSTRUCTION, FROM INCLEMENT WEATHER, THEFT, AND OTHER HAZARDS. THE GENERAL CONTRACTOR SHALL FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS FOR STORAGE OF MATERIALS. PARTIALLY COMPLETED WALLS SHALL BE COVERED TO PROTECT FROM WATER INTRUSION. DAMAGE, INCLUDING BUT NOT LIMITED TO MOLD, RESULTING FROM WATER INTRUSION DURING CONSTRUCTION SHALL BE REPAIRED AT THE GENERAL CONTRACTOR'S EXPENSE. CLEANING OF MOLD ON GYPSUM BOARD IS NOT
ACCEPTABLE. IF MOLD OCCURS, THE GYPSUM BOARD MUST BE REPLACED.
13. ALL WORK SHOWN ON THESE DRAWINGS IS TO BE CONSIDERED AS "BASE BID" SEE BID ALTERNATE INDEX BELOW AND THE
SPECIFICATIONS FOR FURTHER INFORMATION.
PROJECT TEAM
OWNER
Department of Veterans Affairs Network Contracting Office 21 (NCO 22) 855 M Street, Suite 1020 Fresno, CA 93721
ARCHITECT
Romanyk Consulting (RCC) 3308 Preston Road, Suite 350-164 Plano, TX 75093
Denise Groves, CO denise.groves@va.gov
559-228-6932
Rebecca Olson, AIA
STRUCTURAL ENGINEER
IMEG Corp.
300 North Lake Avenue, 14th Floor Pasadena, CA 91101
Sevan Benjanian, P.E.
PLUMBING ENGINEER
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
CIVIL ENGINEER AND LANDSCAPE
IMEG Corp.
300 North Lake Avenue, 14th Floor Pasadena, CA 91101
IMEG Corp.
300 North Lake Avenue, 14th Floor Pasadena, CA 91101
IMEG Corp.
300 North Lake Avenue, 14th Floor Pasadena, CA 91101
CALIBRE ENGINEERING, INC.
9090 South Ridgeline Boulevard, Suite 105 Highlands Ranch, CO 80129
Mike Iezza, P.E.
Ben Murphy
CONSULTANTS:
Scott Nelson, P.E.
Hanriet Abrahamian, P.E.
LOW VOLTAGE ENGINEER
IMEG Corp.
300 North Lake Avenue, 14th Floor Pasadena, CA 91101
Muhamed Aziz, P.E.
SHEET NUMBERING VICINITY MAPS
1. AREA MAP 2. SITE LOCATION A101
SHEET TYPE
DESIGNATOR
SHEET NUMBER
WITHIN SERIES
DISCIPLINE:
ARCHITECTURAL
GI - GENERAL INFORMATION
GC - GENERAL CONTRACT
AS- ARCHITECTURAL SITE
AD - DEMOLITION
AE- ARCHITECTURAL ELEMENTS
AI- ARCHITECTURAL INTERIORS
AF- ARCHITECTURAL FINISHES
C-CIVIL
CD - DEMOLITION & EROSION CONTROL
CE- EXISTING CONDITIONS
CG - GRADING
CS - CIVIL SITE
CU - CIVIL UTILITIES
L - LANDSCAPE
S- STRUCTURAL
SB - STRUCTURAL SUBSTRUCTURE
SF- STRUCTURAL FRAMING
SJ - STRUCTURAL DETAILS
SK - PERSPECTIVE
FA-FIRE PROTECTION DETECTION AND ALARM
FX- FIRE PROTECTION SUPPRESSION
P- PLUMBING
PS - PLUMBING SITE
PL- PLUMBING FIXTURES
M- MECHANICAL
MH- MECHANICAL HVAC
MJ- MECHANICAL DETAILS
E- ELECTRICAL
EL- ELECTRICAL LIGHTING
ELP-LIGHTNING PROTECTION
EP- ELECTRICAL POWER
ES- ELECTRICAL SITE
ET- ELECTRICAL TELECOMMUNICATIONS
TS- TELECOMMUNICATIONS SITE PLAN
BID ALTERNATE INDEX
BID ALTERNATE#1
BID ALTERNATE #2
BID ALTERNATE #3
BID ALTERNATE #4
BID ALTERNATE #5
BID ALTERNATE #6
SEE SHEETS: 1/AE102, 1/AE105, 1/AE201, 2/AE201,
6/AF101, & 2/AF102
SEE SHEETS: 1/AE101 & 3/AI103
SEE SHEETS: 2/AS101 & 3/AS101
SEE SHEET: 1/AS101
SEE SHEET: 1/AE101, 1/AE201, 2/AE201, 4/AI103, &
5/AI103
SEE SHEET: 1/AS101
*NOTE: BID ALTERNATES WILL BE CLOUDED ON THE APPLICABLE SHEETS
PETER A. McCUEN BLVD.
F E
M O
Y E
R S
T
APPROVED BUILDING SITE
FUTURE EXTENSION OF MCCUEN
TWO
STORY BUILDING
FOOT PRINT
25' PSDM SETBACK
LINES
SITE
VA MEDICAL
CENTER
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
IMEG CORP. (M,E,P, & S)
300 NORTH LAKE AVENUE, 14TH FLOOR
PASADENA, CA 91101
CALIBRE ENGINEERING, INC. (CIVIL AND LANDSCAPE)
9090 SOUTH RIDGELINE BOULEVARD, SUITE 105
HIGHLANDS RANCH, CO 80129
KLEINFELDER (GEOTECH)
6700 KOLL CENTER PARKWAY
SUITE 120
PLEASANTON, CA 94566
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
B
IM
/V
IS
N
M a th e r
S o c ia l S e rv ic e s B u ild in g /M a th e r
S o c ia l S e rv ic e s
S
D
.r v t
/1
/2
:4
:1
P M
COVER SHEET
GC EM
CONSTRUCTION
DOCUMENT SUBMISSION
FULLY SPRINKLERED
612-163
GI101
DESIGN SOCIAL WORK AND
EXPAND CLINICAL SPACE
3551 Femoyer Street Mather, CA 95655
12/04/2020
DESIGN SOCIAL WORK
AND EXPAND CLINICAL SPACE
Department of Veterans Affairs Site Location
VA Northern California Health Care System
3551 Femoyer Street Mather, CA 95655
Project Number - 612-163 RCC Contract Number - VA261-17-C-0044
CONSTRUCTION DOCUMENT SUBMISSION #2
DECEMBER 4, 2020
SHEET
NUMBER SHEET TITLE
MH201 HVAC PIPING FIRST FLOOR PLAN
MH202 HVAC PIPING SECOND FLOOR PLAN
MH203 HVAC PIPING ROOF PLAN
MH301 AIR BALANCE SUMMARY
MH401 HVAC CONTROLS
MH402 HEATING WATER FLOW DIAGRAM
MH501 MECHANICAL SECTIONS
MJ601 MECHANICAL DETAILS
MJ602 MECHANICAL DETAILS
MJ603 MECHANICAL DETAILS
E-001 ELECTRICAL SYMBOLS, ABBREVIATIONS, AND
GENERAL NOTES
E-002 ELECTRICAL LIGHTING FIXTURE SCHEDULE
E-003 PANEL SCHEDULES
E-004 PANEL SCHEDULES
ES101 ELECTRICAL SITE PLAN
EL101 ELECTRICAL FIRST FLOOR LIGHTING PLAN
EL102 ELECTRICAL SECOND FLOOR LIGHTING PLAN
EL103 ELECTRICAL ROOF LIGHTING PLAN
ELP103 LIGHTING PROTECTION PLAN
EP101 ELECTRICAL FIRST FLOOR POWER PLAN
EP102 ELECTRICAL SECOND FLOOR POWER PLAN
EP103 ELECTRICAL ROOF POWER PLAN
E-201 ELECTRICAL FIRST FLOOR PHOTOMETRIC
CALCULATIONS
E-202 ELECTRICAL SECOND FLOOR PHOTOMETRIC
CALCULATIONS
E-203 ELECTRICAL FIRST FLOOR PHOTOMETRIC
CALCULATIONS-EMERGENCY
E-204 ELECTRICAL SECOND FLOOR PHOTOMETRIC
CALCULATIONS-EMERGENCY
E-205 ELECTRICAL SITE PLAN PHOTOMETRIC
CALCULATIONS
E-206 ELECTRICAL SITE PLAN PHOTOMETRIC
CALCULATIONS-EMERGENCY
E-210 ELECTRICAL CROSS SECTIONS
E-300 ELECTRICAL SINGLE LINE DIAGRAM
E-401 ELECTRICAL DETAILS
E-402 ELECTRICAL DETAILS
E-403 ELECTRICAL DETAILS
E-404 ELECTRICAL DETAILS
E-405 ELECTRICAL DETAILS
E-406 LIGHTNING PROTECTION DETAILS
E-407 LIGHTNING PROTECTION DETAILS
E-408 LIGHTNING PROTECTION DETAILS
ET001 TELECOMMUNICATION SYMBOLS, ABBREVIATIONS,
AND GENERAL NOTES
TS101 TELECOMMUNICATION SITE PLAN
ET101 TELECOMMUNICATION FIRST FLOOR PLAN
ET102 TELECOMMUNICATION SECOND FLOOR PLAN
ET401 TELECOMMUNICATION ENLARGED PLANS
ET402 TELECOMMUNICATION DETAILS
ET403 TELECOMMUNICATION DETAILS
ET404 TELECOMMUNICATION RISER DIAGRAM
ET501 TELECOMMUNICATIONS SCHEDULES
SHEET
NUMBER SHEET TITLE
AI118 SEISMIC DETAILS
AI119 MISCELLANEOUS DETAILS
AF101 MILLWORK ELEVATIONS
AF102 MILLWORK SECTIONS & ENLARGED PLAN
AF103 DOOR AND WINDOW SCHEDULE AND DETAILS
AF104 ROOM FINISH SCHEDULE
AF105A WALL TYPES
AF105B WALL TYPES
AF106 ALUMINUM FRAME TYPES
AF107 ALUMINUM FRAME TYPES
AF108 ALUMINUM FRAME TYPES
FA001 FIRE ALARM GENERAL NOTES AND EQUIPMENT
LIST
FA101 FIRE ALARM FIRST FLOOR PLAN
FA102 FIRE ALARM SECOND FLOOR PLAN
FA200 FIRE ALARM CALCULATIONS AND RISER DIAGRAM
FA301 FIRE ALARM DETAILS
FA302 FIRE ALARM DETAILS
FX001 FIRE PROTECTION SYMBOLS, ABBREVIATIONS, AND
GENERAL NOTES
FXS101 FIRE PROTECTION SITE PLAN
FX101 FIRE PROTECTION FIRST FLOOR PLAN
FX102 FIRE PROTECTION SECOND FLOOR PLAN
FX201 FIRE PROTECTION FIRST FLOOR REFLECTED
CEILING PLAN
FX202 FIRE PROTECTION SECOND FLOOR REFLECTED
CEILING PLAN
FX301 FIRE PROTECTION DETAILS
P-001 PLUMBING SYMBOLS, ABBREVIATIONS, AND
GENERAL NOTES
P-002 PLUMBING SCHEDULES
P-003 PLUMBING CALCULATIONS
PS101 PLUMBING SITE PLAN
PL101.2 PLUMBING FIRST FLOOR PLAN - UNDERGROUND
PL101A PLUMBING FIRST FLOOR PLAN - WATER
PL101B PLUMBING FIRST FLOOR PLAN - WASTE
PL102A PLUMBING SECOND FLOOR PLAN - WATER
PL102B PLUMBING SECOND FLOOR PLAN - WASTE
PL103 PLUMBING ROOF PLAN
PL201 PLUMBING DOMESTIC WATER RISER DIAGRAMS
PL202 PLUMBING DOMESTIC WATER RISER DIAGRAM
PL203 PLUMBING WASTE AND VENT RISER DIAGRAM
PL204 PLUMBING WASTE AND VENT RISER DIAGRAM
PL205 PLUMBING GAS RISER DIAGRAM
PL206 PLUMBING STORM RISER DIAGRAM
PL301 ENLARGED PLANS
PL401 PLUMBING DETAILS
M-001 MECHANICAL SYMBOLS, ABBREVIATION, AND
GENERAL NOTES
M-002 MECHANICAL SCHEDULES
M-003 MECHANICAL FIRST FLOOR ZONING PLAN
M-004 MECHANICAL SECOND FLOOR ZONING PLAN
MH101 MECHANICAL FIRST FLOOR PLAN
MH102 MECHANICAL SECOND FLOOR PLAN
MH103 MECHANICAL ROOF PLAN
SHEET
NUMBER SHEET TITLE
SJ302 MOMENT FRAME ELEVATIONS
SJ303 MOMENT FRAME ELEVATIONS
SJ304 ELEVATIONS AND BUILDING SECTIONS
SJ401 FOUNDATION DETAILS
SJ402 FOUNDATION DETAILS
SJ403 FOUNDATION DETAILS
SJ501 STEEL DETAILS
SJ502 STEEL DETAILS
SJ601 EXTERIOR STAIR PARTIAL FRAMING PLANS
SJ602 ENCLOSED STAIR PARTIAL FRAMING PLANS
SJ603 STAIR DETAILS
SK101 BUILDING PERSPECTIVES
AS101 ARCHITECTURAL SITE PLAN
AD101 DEMOLITION PLAN
AE101 FIRST FLOOR PLAN
AE102 SECOND FLOOR PLAN
AE103 FIRST FLOOR DIMENSION PLAN
AE104 SECOND FLOOR DIMENSION PLAN
AE105 ROOF PLAN
AE106 FIRST FLOOR REFLECTED CEILING PLAN
AE107 SECOND FLOOR REFLECTED CEILING PLAN
AE201 ELEVATIONS
AE202 ELEVATIONS
AE203 ELEVATIONS
AE204 BUILDING ELEVATION VIEWS
AE205 BUILDING CROSS SECTIONS
AE206 BUILDING LONGITUDINAL SECTIONS
AI101 WALL SECTIONS
AI102 WALL SECTIONS
AI103A WALL SECTIONS
AI103B WALL SECTIONS & GATE ELEVATION
AI104A ENLARGED TOILET PLANS AND ELEVATIONS
AI104B ENLARGED TOILET PLANS AND ELEVATIONS
AI105A ENLARGED STAIR PLANS
AI105B ENLARGED STAIR SECTIONS
AI106 ENLARGED ELEVATOR PLAN AND SECTIONS
AI107 STAIR DETAILS
AI108 STAIR DETAILS
AI109A WALL DETAILS
AI109B WALL DETAILS
AI109C FOUNDATION DETAILS
AI109D FOUNDATION DETAILS
AI110A COLUMN DETAILS
AI110B COLUMN DETAILS
AI110C COLUMN DETAILS
AI111 TYPICAL GYPSUM BOARDS- ELEVATORS - DETAILS
AI112 TYPICAL GYPSUM BOARD ELEVATOR DETAILS
AI113A CEILING DETAILS
AI114B CEILING DETAILS
AI114C CEILING DETAILS
AI115 ROOF DETAILS
AI116 CURVED ROOF AND SUN CONTROL DEVICE
DETAILS
AI117 SEISMIC DETAILS
SHEET
NUMBER SHEET TITLE
GI101 COVER SHEET
GI102 PROJECT DATA
GI103 GENERAL NOTES, ABBREVIATIONS
GC101 FIRST FLOOR LIFE SAFETY PLAN
GC102 SECOND FLOOR LIFE SAFETY PLAN
CE-100 EXISTING CONDITIONS PLAN
CD-100 DEMOLITION AND EROSION CONTROL PLAN
CG-100 GRADING PLAN
CS-100 SITE PLAN
CU-100 OVERALL UTILITY PLAN
L-101 LANDSCAPE PLANTING PLAN
L-201 LANDSCAPE IRRIGATION PLAN
L-301 LANDSCAPE IRRIGATION AND PLANTING DETAILS
S001 STRUCTURAL GENERAL NOTES, LEGEND AND
ABBREVIATIONS
S002 STRUCTURAL GENERAL NOTES
S003 TYPICAL CONCRETE DETAILS
S004 TYPICAL CONCRETE DETAILS
S005 TYPICAL STEEL DETAILS
S006 TYPICAL STEEL DETAILS
S007 TYPICAL STEEL DETAILS
S008 TYPICAL STEEL DETAILS
S009 TYPICAL STEEL DETAILS
S010 TYPICAL STEEL DETAILS
SB101 FOUNDATION PLAN
SF101 SECOND FLOOR FRAMING PLAN
SF102 ROOF FRAMING PLAN
SF103 PARTIAL FRAMING PLANS
SJ301 MOMENT FRAME ELEVATIONS
SD-1 PACKAGE - ORIGINAL SUBMITTAL 5/24/2017
SD-1 PACKAGE - RESUBMITTAL
SD-1 PACKAGE - RESUBMITTAL
SD-1 PACKAGE - RESUBMITTAL - SITE LOCATIONS
8/15/2017
9/15/2017
12/5/2017
SD-2 PACKAGE 5/15/2018
DD-1 NON REVIEW 8/02/2018
DD-1 SUBMISSION 8/23/2018
DD-2 SUBMISSION 10/27/2018
CD-1 SUBMISSION 02/10/2019
CD-1 RE-SUBMISSION 04/12/2019
CD-1 RE-SUBMISSION 01/31/2020
CD-2 SUBMISSION 04/30/2020
CONSTRUCTION DOCUMENT SUBMISSION 06/29/2020
REVIEW SET FOR CONSTRUCTION DOCUMENT SUBMISSION #2 09/24/2020
12/04/2020 CONSTRUCTION DOCUMENT SUBMISSION #2
300 GROSS
7 NET
5 NET
15 NET
BUSINESS AREAS 150 GROSS
EXERCISE ROOMS 50 GROSS
INDUSTRIAL AREAS 100 GROSS
KITCHENS, COMMERCIAL 200 GROSS
a
20 NET
50 NET
500 GROSS
a
200e 250b
NOT PERMITTED 250b
B 200 300c
300 400c
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
75d
100d
150d
175d
200c
IBC CHAPTER 3 - OCCUPANCY CLASSIFICATION:
302 CLASSIFICATION
303.1 ASSEMBLY GROUP
304.1 BUSINESS GROUP B
306.2 FACTORY INDUSTRIAL F-1 MODERATE-HAZARD OCCUPANCY
306.3 FACTORY INDUSTRIAL F-2 LOW-HAZARD OCCUPANCY
311.2 MODERATE-HAZARD STORAGE, GROUP S-1
311.3 LOW-HAZARD STORAGE, GROUP S-2
312 UTILITY AND MISCELLANEOUS GROUP U
IBC CHAPTER 6 - TYPES OF CONSTRUCTION:
Type IA Type IB Type IIA Type IIB Type IIIA Type IIIB Type IV
Type VA
Type VB
TABLE 1004.5
MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
ACCESSORY STORAGE AREAS,
MECHANICAL EQUIPMENT ROOM
SEE SECTION 1004.6
FUNCTION OF SPACE OCCUPANT LOAD FACTOR
ASSEMBLY WITH FIXED SEATS
ASSEMBLY WITHOUT FIXED SEATS
CONCENTRATED (CHAIRS ONLY - NOT FIXED)
STANDING SPACE
UNCONCENTRATED (TABLES AND CHAIRS)
EDUCATIONAL
CLASSROOM AREA
SHOPS AND OTHER VOCATIONAL ROOM AREAS
WAREHOUSES
BUILDING CODE 2018
IBC CHAPTER 5 - GENERAL BUILDING HEIGHTS AND AREAS:
TABLE 503 ALLOWABLE BUILDING HEIGHTS AND AREAS
A. SEE THE FOLLOWING SECTIONS FOR GENERAL EXCEPTIONS TO TABLE 503
SECTION 507 UNLIMITED AREA BUILDINGS
507.1 GENERAL. THE AREA OF BUILDINGS OF THE OCCUPANCIES AND CONFIGURATIONS SPECIFIED IN
SECTIONS 507.1 THROUGH 507.12 SHALL NOT BE LIMITED.
507.5 TWO STORY. THE AREA OF A GROUP B, F, M OR S BUILDING NO MORE THAN TWO STORIES ABOVE GRADE PLANE SHALL NOT BE LIMITED WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1, AND IS SURROUNDED AND
ADJOINED BY PUBLIC WAYS OR YARDS NOT LESS THAN 60 FEET (18 288 MM) IN WIDTH.
508.2.4 SEPARATION OF OCCUPANCIES. NO SEPARATION IS REQUIRED BETWEEN ACCESSORY
OCCUPANCIES AND THE MAIN OCCUPANCY. (BUSINESS - STORAGE)
508.3 NONSEPARATED OCCUPANCIES. BUILDINGS OR PORTIONS OF BUILDINGS THAT
COMPLY WITH THE PROVISIONS OF THIS SECTION SHALL BE CONSIDERED AS
NONSEPARATED OCCUPANCIES.
508.3.1 OCCUPANCY CLASSIFICATION. NONSEPARATED OCCUPANCIES SHALL BE
INDIVIDUALLY CLASSIFIED IN ACCORDANCE WITH SECTION 302.1. THE
REQUIREMENTS OF THIS CODE SHALL APPLY TO EACH PORTION OF THE BUILDING
BASED ON THE OCCUPANCY CLASSIFICATION OF THE SPACE. IN ADDITION, THE MOST
RESTRICTIVE PROVISION OF CHAPTER 9 WHICH APPLY TO THE NONSEPARATED
OCCUPANCIES SHALL APPLY TO THE TOTAL NONSEPARATED OCCUPANCY AREA.
WHERE NONSEPARATED OCCUPANCIES OCCUR IN A HIGH-RISE BUILDING, THE MOST
RESTRICTIVE REQUIREMENTS OF SECTION 403 WHICH APPLY TO THE
NONSEPARATED OCCUPANCIES SHALL APPLY THROUGHOUT THE HIGH-RISE
BUILDING.
508.3.3 SEPARATION. NO SEPARATION IS REQUIRED BETWEEN NONSEPARATED
OCCUPANCIES. (B - S-1)
SECTION 1009 ACCESSIBLE MEANS OF EGRESS
1009.1 ACCESSIBLE MEANS OF EGRESS REQUIRED. ACCESSIBLE MEANS OF EGRESS SHALL
COMPLY WITH THIS SECTION. ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN
ONE ACCESSIBLE MEANS OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS IS REQUIRED
BY SECTION 1006.2 OR 1006.3 FROM ANY ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF
THE SPACE SHALL BE SERVED BY NOT LESS THAN TWO ACCESSIBLE MEANS OF EGRESS.
1009.7 EXTERIOR AREAS FOR ASSISTED RESCUE. EXTERIOR AREA FOR ASSISTED RESCUE SHALL
BE ACCESSED BY AN ACCESSIBLE ROUTE FROM THE AREA SERVED.
WHERE THE EXIT DISCHARGE DOES NOT INCLUDE AN ACCESSIBLE ROUTE FROM AN EXIT
LOCATED ON THE LEVEL TO THE LEVEL OF EXIT DISCHARGE TO A PUBLIC WAY, AN EXTERIOR
AREA OF ASSISTED RESCUE SHALL BE PROVIDED ON THE EXTERIOR LANDING IN ACCORDANCE
WITH SECTIONS 1009.7.1 THROUGH 1009.7.4.
1009.7.1 SIZE. EACH EXTERIOR AREA FOR ASSISTED RESCUE SHALL BE SIZED TO
ACCOMMODATE WHEELCHAIR SPACES IN ACCORDANCE WITH SECTION 1009.6.3
1009.7.4 SEPARATION. EXTERIOR WALLS SEPARATING THE EXTERIOR AREA OF
ASSISTED RESCUE FROM THE INTERIOR OF THE BUILDING SHALL HAVE A MINIMUM
FIRE-RESISTANCE RATING OF 1 HOUR, RATED FOR EXPOSURE TO FIRE FROM THE
INSIDE. THE FIRE-RESISTANCE-RATED EXTERIOR WALL CONSTRUCTION SHALL
EXTEND HORIZONTALLY NOT LESS THAN 10 FEET (93048MM) BEYOND THE
LANDING ON EITHER SIDE OF THE LANDING OR EQUIVALENT FIRE-RESISTANCE-
RATED CONSTRUCTION IS PERMITTED TO EXTEND OUT PERPENDICULAR TO THE
EXTERIOR WALL NOT LESS THAN 4 FEET (1219MM) MINIMUM ON THE SIDE OF THE
LANDING. THE FIRE-RESISTANCE-RATED CONSTRUCTION SHALL EXTEND
VERTICALLY FROM THE GROUND TO A POINT NOT LESS THAN 10 FEET (3048 MM)
ABOVE THE FLOOR LEVEL OF THE AREA FOR ASSISTED RESCUE OR TO THE ROOF
LINE, WHICHEVER IS LOWER. OPENINGS WITHIN SUCH FIRE-RESISTANCE-RATED
EXTERIOR WALL SHALL BE PROTECTED IN ACCORDANCE WITH SECTION 716.
EXCEPTION: THE FIRE-RESISTANCE RATING AND OPENING PROTECTIVES
ARE NOT REQUIRED IN THE EXTERIOR WALL WHERE THE BUILDING IS EQUIPPED
THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALL IN ACCORDANCE
WITH SECTION 903.3.1.1 OR 903.3.1.2.
1009.7.5 OPENNESS. THE EXTERIOR AREA FOR ASSISTED RESCUE SHALL BE OPEN
TO THE OUTSIDE AIR. THE SIDES OTHER THAN THE SIDE SEPARATION WALLS
SHALL BE AT LEAST 50 PERCENT OPEN, AND THE OPEN AREA SHALL BE
DISTRIBUTED SO AS TO MINIMIZE THE ACCUMULATION OF SMOKE OR TOXIC
GASES.
1009.7.6 STAIRWAY. STAIRWAYS THAT ARE PART OF THE MEANS OF EGRESS FOR
THE EXTERIOR AREA FOR ASSISTED RESCUE SHALL PROVIDE A CLEAR WIDTH OF
48 INCHES (1219 MM)BETWEEN HAND-RAILS.
EXCEPTION: THE CLEAR WIDTH OF 48 INCHES (1219 MM) BETWEEN HAND-
RAILS IS NOT REQUIRED AT STAIRWAYS SERVING BUILDINGS EQUIPPED
THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN
ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2
SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS:
SECTION 1019.3 ALLOWS FOR OPEN COMMUNICATING STAIR(S) BETWEEN
BOTH FLOORS.***
1020.4 DEAD ENDS. WHERE MORE THAN ONE EXIT OR EXIT ACCESS
DOORWAY IS REQUIRED, THE EXIT ACCESS SHALL BE ARRANGED SUCH THAT
DEAD-END CORRIDORS DO NOT EXCEED 20 FEET (6096 MM) IN LENGTH.
EXCEPTIONS:
2. IN OCCUPANCIES IN GROUPS B, E, F, I-1, M, R-1, R-2, R-4, S AND U,
WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC
SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1, THE LENGTH
OF THE DEAD-END CORRIDORS SHALL NOT EXCEED 50 FEET (15 240 MM).
SECTION 1101 GENERAL
1101.1 SCOPE. THE PROVISIONS OF THIS CHAPTER SHALL CONTROL THE DESIGN AND CONSTRUCTION
OF FACILITIES FOR ACCESSIBILITY FOR INDIVIDUALS WITH DISABILITIES.
1102.1 DESIGN. BUILDINGS AND FACILITIES SHALL BE DESIGNED AND CONSTRUCTED TO BE
ACCESSIBLE IN ACCORDANCE WITH THIS CODE AND ICC A117.1.
1103.2.9 EQUIPMENT SPACES. SPACES FREQUENTED ONLY BY SERVICE PERSONNEL FOR
MAINTENANCE, REPAIR OR OCCASIONAL MONITORING OF EQUIPMENT ARE NOT REQUIRED TO COMPLY
WITH THIS CHAPTER.
1109.12.1 DRESSING, FITTING AND LOCKER ROOMS. WHERE DRESSING ROOMS, FITTING ROOMS OR LOCKER ROOMS ARE PROVIDED, AT LEAST 5 PERCENT, BUT NOT LESS THAN ONE, OF EACH TYPE OF
USE IN EACH CLUSTER PROVIDED SHALL BE ACCESSIBLE.
TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCE
OCCUPANCY WITHOUT SPRINKLER
SYSTEM
(FEET)
WITH SPRINKLER
SYSTEM
(FEET)
A, E, F-1, M, R, S-1 I-1
F-2, S-2, U H-1 H-2 H-3 H-4 H-5
I-2, I-3
ALL CODES SHALL BE THE LATEST PUBLISHED VERSION
BUILDING CODE: 2018 ICC INTERNATIONAL BUILDING CODE ® (IBC)
NFPA 101 LIFE SAFETY CODE
NFPA NATIONAL FIRE CODES WITH EXCEPTION OF NFPA 5000 AND NFPA 900
ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS, VA SUPPLEMENT, BARRIER FREE DESIGN GUIDE
PLUMBING CODE: INTERNATIONAL PLUMBING CODE
ELECTRICAL CODE: NATIONAL ELECTRICAL CODE
VA PHYSICAL SECURITY DESIGN MANUAL (PSDM) - JANUARY 2015
**VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN. DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC
REQUIREMENTS ARE DIFFERENT).
IBC CHAPTER 10: MEANS OF EGRESS
IBC CHAPTER 11: ACCESSIBILITY
PROJECT SUMMARY:
BUSINESS OCCUPANCY
TYPE V-A CONSTRUCTION (TABLE 504.3)
FULLY SPRINKLERED
(BUILDING)
FLOOR AREA IN SQ. FT PER OCCUPANT = 150
FIRST FLOOR 7,445 S.F. /150
SECOND FLOOR 6,724 S.F. /150
TOTAL OCCUPANCY 14,169 S.F. / 150 = 94
EXIT WIDTH 93 X .2" = 19"
(ACCESSORY)
STORAGE 399 S.F. / 300 = 1.33
EXIT WIDTH 1.33 X .15" = .2"
(EXIT WIDTH IS .15" PER OCCUPANT FOR EGRESS COMPONENT AND .2"
FOR STAIRS IN FULLY SPRINKLED BUILDINGS)
NFPA 101:
SECTIONS 8.6.6 AND 43.10.4.7.1 ALLOW FOR COMMUNICATING STAIR(S) TO BE NON-RATED
AND OPEN TO BOTH FLOORS
STAIRWAYS
(INCHES PER
OCCUPANT)
0.2 a
1005 MEANS OF EGRESS SIZING ILLUSTRATED
OCCUPANCY
WITH SPRINKLER SYSTEM
OCCUPANCIES OTHER THAN H,
AND I-2
OTHER EGRESS
COMPONENTS
(INCHES PER OCCUPANT)
0.15
CONCENTRATED BUSINESS USE AREA SEE SECTION 1004.6
75 75a
Not Permitted
Not Permitted
TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
MAXIMUM OCCUPANT
LOAD OF SPACE
WITHOUT SPRINKLER
SYSTEM
(feet)
WITH
SPRINKLER
SYSTEM
(feet)
Occupant Load
OL 30 OL>30
I-3
OCCUPANCY
H-4, H-5 I-1, I-2d, I-4
H-1, H-2, H-3
Ac, E, M B F
R-1 R-2 R-3e
R-4e
Sf
U
Not Permitted Not Permitted Not Permitted Not Permitted Not Permitted Not Permitted Not Permitted
Not Permitted Not Permitted Not Permitted Not Permitted Not Permitted Not Permitted Not Permitted
100a
100a
25b
75b 75a
100a
75a
125a
125a, g
125a, g
100a
75a
1006.2.1 EGRESS BASED ON OCCUPANT LOAD AND COMMON PATH OF EGRESS
TRAVEL DISTANCE.
TWO EXITS OR EXIT ACCESS DOORWAYS FROM ANY SPACE SHALL BE PROVIDED
WHERE THE DESIGN OCCUPANT LOAD OR THE COMMON PATH OF EGRESS TRAVEL
DISTANCE EXCEEDS THE VALUE LISTED IN TABLE 1006.2.1. THE CUMULATIVE
OCCUPANT LOAD FROM ADJACENT ROOMS, AREAS OR SPACES SHALL BE
DETERMINED IN ACCORDANCE WITH SECTION 1004.2.
1.THE NUMBER OF EXITS FROM FOYERS, LOBBIES, VESTIBULES OR SIMILAR
SPACES NEED NOT BE BASED ON CUMULATIVE OCCUPANT LOADS FOR AREAS
DISCHARGING THROUGH SUCH SPACES, BUT THE CAPACITY OF THE EXITS FROM
SUCH SPACES SHALL BE BASED ON APPLICABLE CUMULATIVE OCCUPANT LOADS.
I-4 150 200c
200c
1006.3.2 EGRESS BASED ON OCCUPANT LOAD. EACH STORY AND OCCUPIED
ROOF SHALL HAVE THE MINIMUM NUMBER OF SEPARATED AND DISTINCT
EXITS, OR ACCESS TO EXITS, AS SPECIFIED IN TABLE 1006.3.2. A SINGLE EXIT
OR ACCESS TO A SINGLE EXIT SHALL BE PERMITTED IN ACCORDANCE WITH
SECTION 1006.3.3 THE REQUIRED NUMBER OF EXITS, OR EXIT ACCESS
STAIRWAYS OR RAMPS PROVIDING ACCESS TO EXITS, FROM ANY STORY OR
OCCUPIED ROOF SHALL BE MAINTAINED UNTIL ARRIVAL AT THE EXIT
DISCHARGE OR A PUBLIC WAY.
TABLE 1006.3.2 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
MINIMUM NUMBER OF EXITS OR
ACCESS TO EXITS FROM STORY
OCCUPANT LOAD
PER STORY
1-500
501-1,000
MORE THAN 1,000
1006.3.3 SINGLE EXITS. A SINGLE EXIT OR ACCESS TO SINGLE EXIT SHALL BE
PERMITTED FROM ANY STORY OR OCCUPIED ROOM WHERE ONE OF THE
FOLLOWING EXISTS:
1. THE OCCUPANT LOAD, NUMBER OF WELLING UNITS AND COMMON
PATH OF EGRESS TRAVEL DISTANCE DO NOT EXCEED THE VALUES IN TABLE
1006.3.3(1) OR 1006.3.3(2)
2. ROOMS, AREAS AND SPACES COMPLYING WITH SECTION 1006.2.1
WITH EXITS THAT DISCHARGE DIRECTLY TO THE EXTERIOR AT THE LEVEL OF
EXIT DISCHARGE, ARE PERMITTED TO HAVE ONE EXIT OR ACCESS TO A
SINGLE EXIT.
(ACCESSORY)
STORAGE
BUILDING
A. BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2.
SEE SECTION 903 FOR OCCUPANCIES WHERE AUTOMATIC SPRINKLER SYSTEMS ARE PERMITTED IN ACCORDANCE WITH SECTION 903.3.1.2.
F. THE LENGTH OF COMMON PATH OF EGRESS TRAVEL DISTANCE IN A GROUP S-2 OPEN PARKING GARAGE SHALL BE NOT MORE THAN 100
FEET.
C. BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1.
(ACCESSORY)
STORAGE
BUILDING
(ACCESSORY)
STORAGE
BUILDING
(ACCESSORY)
STORAGE
BUILDING
BUILDING
BUILDING
FIRST FLOOR = 5 EXITS
SECOND FLOOR = 2
EXITS /EXIT ACCESS
(ACCESSORY)
STORAGE (ACCESSORY)
STORAGE
HAS SINGLE EXITS. OCCUPANT
LOAD IS 2 FOR THIS SPACE.
BUILDING
FIRST FLOOR
OCCUPANT LOAD: 50
SECOND FLOOR
OCCUPANT LOAD: 44
TOTAL OCCUPANTS: 94
(ACCESSORY)
STORAGE
OCCUPANT LOAD : 2
REFERENCE ARCHITECTURAL BARRIERS ACT (ABA)
PROPOSED PHASING SCHEDULE:
1. PHASE 1. CONNECT ALL OFF SITE UTILITIES TO THE SITE INCLDING TRENCHING, CITY PERMITS, LAYING PIPE, POWER CABLES, COMMUNICATIONS
CABLING AND GAS PIPING TO THE SITE AS REQUIRED FOR THIS PROJECT.
2. PHASE 2: COORDINATE WITH THE VA AND THE AHJ FOR ANY CURB CUTS, ROAD CLOSURES, AND TRENCHING TO BROACH THE CITY OWNED STREETS AND CURB/GUTTER. ALSO COORDINATE THE PLACEMENT OF SECURITY FENCES AND SOIL EROSION BARRIERS WITH BOTH THE VA
AND THE AHJ
3. PHASE 3: COORDINATE WITH THE VA CONCERNING ANY FUTURE ROADS PLANNED ON THE ENTIRETY OF THE CONSTRUCTION SITE AND OWNED
VA PROPERTY THAT THE BUILDING AND THE LIMITED SITE WORK WILL BE ON.
4. PHASE 4: COORDINATE WITH THE VA AND AHJ FOR THE REMAINDER OF THE WORK, OUTSIDE THESE DOCUMENTS, THAT WILL NEED TO
COORDINATE WITH THE CONSTRUCTION DOCUMENTS GIVEN HERE.
5. PHASE 5: COORDINATE THE PLACEMENT OF ANY TRAILERS AND MATERIALS STAGING ON THE PROPERTY AS PART OF THE CONSTRUCTION SCHEDULE TO BE SUBMITTED TO THE VA FOR APPROVAL , PRIOR TO STARTING CONSTRUCTION BY THE GENERAL CONTRACTOR.
6. PHASE 6: CONSTRUCTION OF THE BUILDING ON THE SITE SHALL BE COORDINATED WITH ALL TRADES, THE VA, AND THE AHJ WITH A CONSTRUCTION
SCHEDULE GIVEN TOTHE VA BY THE GENERAL CONTRACTOR PRIOR TO STARTING CONSTRUCTION
7. PHASE 7: COORDINATE SIDEWALKS, PARKING PAVEMENT, LANDSCAPING AND SIGNAGE WITH THE VA AS PART OF THE CONSTRUCTION SCHEDULE
CREATED BY THE GENERAL CONTRACTOR PRIOR TO THE START OF CONSTRUCTION
8. PHASE 8: REMOVE ALL TEMPORARY POWER, SECURITY FENCES, SOIL EROSION BARRIERS AND SIDEWALK SAFETY BARRIERS FROMTHE SITE AFTER
ALL CONSTRUCTION IS COMPLETE AND HAS BEEN APPROVED BYTHE VA COR.
EXTERIOR WALLS SHALL BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH TABLES
601 AND 602 AND THIS SECTION.
3 A,B
SECTION 601
GENERAL
TABLE 601
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
BUILDING ELEMENT TYPE I
PRIMARY STRUCTURAL FRAME f (See Section 202)
A B 2 A,B
TYPE II
A B A B
TYPE III
HT
TYPE IV TYPE V
A B
BEARING WALLS
EXTERIOR e,f
INTERIOR
NONBEARING WALLS AND PARTITIONS
EXTERIOR
NONBEARING WALLS AND PARTITIONS
INTERIORd
FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY
MEMBERS (See Section 202)
ROOF CONSTRUCTION AND ASSOCIATED SECONDARY
MEMBERS (See Section 202)
3A 2A
2 1 0 2 2 2 1 0
1 B 0 1 B 0 HT 1 B 0
1 01 0 1 0 1/HT
SEE TABLE 602
0 0 0 0 0 0 0 0
SEE SECTION
2304.11.2
HT
HT
2 2 1 0 1
1 1/2,B 1 B,C 1 B,C 0 C 1 B,C
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
IMEG CORP. (M,E,P, & S)
300 NORTH LAKE AVENUE, 14TH FLOOR
PASADENA, CA 91101
CALIBRE ENGINEERING, INC. (CIVIL AND LANDSCAPE)
9090 SOUTH RIDGELINE BOULEVARD, SUITE 105
HIGHLANDS RANCH, CO 80129
KLEINFELDER (GEOTECH)
6700 KOLL CENTER PARKWAY
SUITE 120
PLEASANTON, CA 94566
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
BI
M
VI
SN
- M at he r S oc ia l S er vi ce s
Bu ild in g/
M at he r S oc ia l S er vi ce s
SD
2.
rv t
/4
/2
2:
:5
PM
PROJECT DATA
GC EM
CONSTRUCTION
DOCUMENT SUBMISSION
FULLY SPRINKLERED
612-163
GI102
DESIGN SOCIAL WORK AND
EXPAND CLINICAL SPACE
3551 Femoyer Street Mather, CA 95655
12/04/2020
SD-1 PACKAGE - ORIGINAL SUBMITTAL 5/24/2017
SD-1 PACKAGE - RESUBMITTAL
SD-1 PACKAGE - RESUBMITTAL
SD-1 PACKAGE - RESUBMITTAL - SITE LOCATIONS
8/15/2017
9/15/2017
12/5/2017
SD-2 PACKAGE 5/15/2018
DD-1 NON REVIEW 8/02/2018
DD-1 SUBMISSION 8/23/2018
DD-2 SUBMISSION 10/27/2018
CD-1 SUBMISSION 02/10/2019
CD-1 RE-SUBMISSION 04/12/2019
CD-1 RE-SUBMISSION 01/31/2020
CD-2 SUBMISSION 04/30/2020
CONSTRUCTION DOCUMENT SUBMISSION 06/29/2020
ARCHITECTURAL DRAWING ABBREVIATIONS ARCHITECTURAL SYMBOLS
LEGEND
CONCRETE/ PRECAST
CONCRETE
SOIL
SAND, EIFS FINISH COAT,
OR CEMENT PLASTER
BRICK
CMU
STONE
FIBERGLASS BATT
INSULATION
EXPANDED
POLYSTYRENE RIGID
INSULATION
EXTRUDED
POLYSTYRENE RIGID
INSULATION
POLYISOCYANURATE
RIGID INSULATION
GYPSUM BOARD
EXTERIOR GYPSUM
SHEATHING
EXTERIOR CEMENT
BOARD
COATED GLASS MAT
WATER RESISTANT
GYP BD
PLYWOOD
COVER BOARD
MATERIALS
CEILING SYMBOLS
FIRE RESISTANT CONSTRUCTION/FIREPROOFING SCHEDULE
ITEM REQ'D RATING / HR UL/FM # WHERE APPLICABLE
- EXTERIOR WALLS: LOAD BEARING
NON-LOAD BEARING
- FIRE/PARTY WALLS
- SHAFTS
- TENANT SEPARATION
- INTERIOR WALL: LOAD BEARING
- NON-LOAD BEARING RATED WALLS
- INTUMESCENT PAINT ON COLUMNS
- BEAMS
- FLOOR/CEILING
- ROOF/CEILING
FIRE PROOFING NOTES
1. ALL FIRE RESISTIVE RATINGS ARE ASSUMED TO BE THERMALLY UNRESTRAINED.
2. ALL BEAMS AND COLUMNS SHALL BE ADJUSTED USING W/D OR A/P RATIOS TO DETERMINE THE
CORRECT FIREPROOFING THICKNESS.
3. ALL COLUMNS ARE TO RECEIVE INTUMESCENT PAINT FOR FIRE PROOFING.
4. ALL BEAMS AND DECKING ARE TO RECEIVE SPRAY ON FIRE PROOFING.
5. CORRIDORS NOT REQUIRED TO BE RATED PER TABLE 1020.1 OF THE IBC FOR "B" OCCUPANCY
A ---------------------
A LABELCLASS A DOOR
A/C AIR CONDITION
A/C UNITAIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNLACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALG ALUMINUM AND GLASS
AL ALUMINUM
ALUM ALUMINUM
ANOD ANODIZE
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AW ARCHITECTURAL WOODWORK
AWT ACOUSTICAL WALL TREATMENT
B ---------------------
B LABELCLASS B DOOR
BALC BALCONY
BB BASEBOARD
BC BOOKCASE
BD BOARD
BDRY BOUNDARY
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BUILDING PAPER
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C CONC CAST CONCRETE
C LABELCLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER) BOARD
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR
INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CLRM CLASSROOM
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABELCLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ELEV EQ ELEVATOR EQUIPMENT
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE BOARD
(INSULATION)
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED
EXT EXTERIOR
EXT EXTINGUISHER
EXT GR EXTERIOR GRADE
N/A
1 HR
N/A N/A
1 HR
N/A N/A
1 HR
UL D8581 HR
1 HR
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FAS BD FASCIA BOARD
FC BRK FACE BRICK
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED PLASTIC
FRTW FIRE RETARDANT TREATED WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GFCI GOVERNMENT FURNISHED CONTRACTOR
INSTALLED
GFGI GOVERNMENT FURNISHED INSTALLED BY
GOVERNMENT
GFRG GLASS-FIBER-REINFORCED GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GSF GROSS SQUARE FEET
GUT GUTTER
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H ---------------------
HAC HOUSE AID KEEPING CLOSET
HB HOSE BIBB
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HMF HOLLOW METAL FRAME
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATION, AND AIR
CONDITIONING
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
ISO ISOLATION
J ---------------------
JAN JANITOR
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REC ROOM RECREATION ROOM
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SHWR SHOWER
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SST STAINLESS STEEL
ST STAIRS
STD STANDARD
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
SUB FL SUBFLOOR
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TC TERRA COTTA
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
FIRE RATED CONSTRUCTION
NOTE: REFER TO OTHER
DISCIPLINES FOR
ADDITIONAL SYMBOLS
SD
GWB CEILING
(MOISTURE RESISTANT
WHERE WATER IS
USED IN THE ROOM)
SMOKE DETECTOR
(REFER TO FA DWGS)
EXIT SIGN LOCATION
(REFER TO FA DWGS)
DIFFUSER
RETURN
CEILING HEIGHT,
ABOVE FINISH FLOOR
2X2 TEGULAR
LAY-IN CEILING
A.F.F.1'-0"
RECESSED CAN
LIGHTING FIXTURE
8' UP/DOWN LED PENDANT
CHAIN HUNG UTILITY
LED FIXTURE (WITH
WIRE GUARD)
WALL MOUNTED
LIGHT
2X2 TEGULAR VINYL
COATED GYP. BD. LAY-
IN CEILING
RECESSED LINEAR LED LIGHT
FIXTURE (IN HARD CEILINGS)
SEE OTHER DISCIPLINES FOR
ADDITIONAL ABREVIATIONS
EXTERIOR
WALL MOUNTED LIGHT
FIXTURE
DECORATIVE LED
PENDANT LIGHT
FIXTURE
C CAMERA
ANNOTATION DRAWING SYMBOLS
NOTE: NOT ALL MAY BE USED
UL D858
UL D858
UL U415
UL X649
UL U4651 HR
N/A N/A N/A
N/A N/A
2x4 LED LIGHT FIXTURE
- CORRIDORS N/A N/A SEE NOTE #5
LINEAR
DIFFUSER
1i
0 GRID / COLUMN
LINE
DESIGNATOR
EQUIPMENT NUMBER
DOOR TAG
A#
WALL TYPE
WINDOW TYPE
Room name
150 SF
ROOM NAME/NUMBER
REVISION TAG
NORTH ARROW
Room Rm_Occupancy
150 SF
ROOM
OCCUPANCY &
AREA
ELEVATION NUMBER
SECTION
EXTERIOR ELEVATION
ENLARGEMENT,
DETAIL
SPOT ELEVATION
Name Elevation FLOOR LEVEL &
NAME
PLATE NUMBER
WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A SHEET KEYNOTE
A-101
1 Ref
R ef
1Ref
R ef
INTERIOR ELEVATION
A-101
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A-101
Ref
R ef
R ef
Ref
A-101
SIM
EGRESS PATH OF
TRAVEL
X'-X"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
IMEG CORP. (M,E,P, & S)
300 NORTH LAKE AVENUE, 14TH FLOOR
PASADENA, CA 91101
CALIBRE ENGINEERING, INC. (CIVIL AND LANDSCAPE)
9090 SOUTH RIDGELINE BOULEVARD, SUITE 105
HIGHLANDS RANCH, CO 80129
KLEINFELDER (GEOTECH)
6700 KOLL CENTER PARKWAY
SUITE 120
PLEASANTON, CA 94566
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
BI
M
VI
SN
- M at he r S oc ia l S er vi ce s
Bu ild in g/
M at he r S oc ia l S er vi ce s
SD
2.
rv t
/4
/2
2:
:0
PM
GENERAL NOTES, ABBREVIATIONS
GC EM
CONSTRUCTION
DOCUMENT SUBMISSION
FULLY SPRINKLERED
612-163
GI103
DESIGN SOCIAL WORK AND
EXPAND CLINICAL SPACE
3551 Femoyer Street Mather, CA 95655
12/04/2020
SD-1 PACKAGE - ORIGINAL SUBMITTAL 5/24/2017
SD-1 PACKAGE - RESUBMITTAL
SD-1 PACKAGE - RESUBMITTAL
SD-1 PACKAGE - RESUBMITTAL - SITE LOCATIONS
8/15/2017
9/15/2017
12/5/2017
SD-2 PACKAGE 5/15/2018
DD-1 NON REVIEW 8/02/2018
DD-1 SUBMISSION 8/23/2018
DD-2 SUBMISSION 10/27/2018
CD-1 SUBMISSION 02/10/2019
CD-1 RE-SUBMISSION 04/12/2019
CD-1 RE-SUBMISSION 01/31/2020
CD-2 SUBMISSION 04/30/2020
CONSTRUCTION DOCUMENT SUBMISSION 06/29/2020
UP
FE
C
FEC
FE
C
GENERAL NOTES
BARRIER LEGEND
126 SF126 SF
PROCEDURE
124 SF124 SF
EXAM
129 SF129 SF
CLEAN
111D
124 SF124 SF
ISO. EXAM
124 SF124 SF
EXAM
124 SF124 SF
EXAM
122 SF122 SF
EXAM
124 SF124 SF
EXAM
103 SF103 SF
VESTIBULE
182 SF182 SF
BREAK RM.
92 SF92 SF
CONSULT RM.
188 SF188 SF
GROUP RM.
1126 SF1126 SF
STAFF AREA
CORRIDOR
PA
SS
EN
G
ER
EL
EV
AT
O R
125 SF125 SF
EXAM
124 SF124 SF
EXAM
STAFF TLT
111A
HAC
195 SF195 SF
RECEPTION
SOILED
111B
TLT.
10A
CORRIDOR
71 SF71 SF
TOILET
105A
74 SF74 SF
SHWR ROOM
104A
77 SF77 SF
TOILET
76 SF76 SF
LAUNDRY
EXTERIOR
STAIR
84 SF84 SF
STORAGE
ENCLOSED
STAIR
124 SF124 SF
EXAM
21 SF21 SF
ELECT.
111C
46 SF46 SF
ELEV EQ
HT/WT
STATION
SECURITY
STATION
R
R
O M
N I
O M
N I
O M
N I
OMNI
TRAVEL DISTANCE: 91'-3"
TRAVEL DISTANCE: 106'-9"
TRAVEL DISTANCE: 78'-0"
TR
AV
EL
D
IS
TA
N C
E:
1' -3
90 SF90 SF
CONSULT RM.
110 SF110 SF
ELECT
76 SF76 SF
TOILET
TO
PUBLIC
WAY
TO PUBLIC WAY
TO PUBLIC WAY
TO PUBLIC WAY
TO
PUBLIC
W
AY
PROVIDE SIGNAGE:
IN CASE OF EMERGENCY DO
NOT ENTER STAIRWELL
SHWR ROOM
102A
1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY. WALL PARTITION
DESIGNATIONS IDENTIFIED ON THIS DRAWING ARE FOR GRAPHICAL
PURPOSES ONLY AND MAY NOT REPRESENT THE ACTUAL WALL
CONSTRUCTION
2. REFER TO OTHER CONSULTANT/DISCIPLINE DRAWINGS FOR
ADDITIONAL DETAILS
3. ALL FIRE RATED PARTITIONS/ASSEMBLIES SHALL BE PERMANENTLY
IDENTIFIED BY STENCIL PAINTING - REFER TO SPECIFICATIONS FOR
DETAILS
4. REFER TO WALL PARTITION TYPE SCHEDULE /DRAWINGS FOR UL
DETAILS ASSOCIATED WITH THE PROJECT SCOPE OF WORK
LED EXIT LIGHT
PATH OF TRAVEL
SYMBOL LEGEND:
RATED WALL LEGEND:
ONE HOUR RATED WALL
X'-X"
EGRESS DIRECTIONAL ARROW
TRAVEL DISTANCE START CIRCLE
BUILDING DATA:
FIRE RESISTANT CONSTRUCTION/
FIREPROOFING SCHEDULE
ITEM REQUIRED RATING
-EXTERIOR WALLS:
LOAD BEARING
NON LOAD BEARING
-FIRE/PARTY WALLS
-SHAFTS
-OCCUPANCY SEPARATION
-INTERIOR WALLS:
LOAD BEARING
NON LOAD BEARING
-COLUMNS
-BEAMS
-FLOOR/CEILING
-ROOF/CEILING
-SMOKE WALLS
-CORRIDOR WALLS
0 HR
1 HR
1 HR
1 HR
1 HR
1 HR
-STAIR ENCLOSURES 1 HR
NET AREA:
FIRST FLOOR: 7,171.89 SF
SECOND FLOOR: 6,397.67 SF
TOTAL: 13,569.56 SF
GROSS AREA:
FIRST FLOOR: 7,553.63 GSF
SECOND FLOOR: 6,732.62 GSF
TOTAL: 14,286 GSF
0 HR
0 HR
0 HR
0 HR
0 HR
0 HR
0 HR
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
IMEG CORP. (M,E,P, & S)
300 NORTH LAKE AVENUE, 14TH FLOOR
PASADENA, CA 91101
CALIBRE ENGINEERING, INC. (CIVIL AND LANDSCAPE)
9090 SOUTH RIDGELINE BOULEVARD, SUITE 105
HIGHLANDS RANCH, CO 80129
KLEINFELDER (GEOTECH)
6700 KOLL CENTER PARKWAY
SUITE 120
PLEASANTON, CA 94566
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
BI
M
VI
SN
- M at he r S oc ia l S er vi ce s
Bu ild in g/
M at he r S oc ia l S er vi ce s
SD
2.
rv t
/4
/2
2:
:4
PM
FIRST FLOOR LIFE SAFETY PLAN
GC EM
CONSTRUCTION
DOCUMENT SUBMISSION
FULLY SPRINKLERED
612-163
GC101
DESIGN SOCIAL WORK AND
EXPAND CLINICAL SPACE
3551 Femoyer Street Mather, CA 95655
12/04/2020
1/8" = 1'-0"1 FIRST FLOOR PLAN LIFE SAFETY PLAN
SD-1 PACKAGE - ORIGINAL SUBMITTAL 5/24/2017
SD-1 PACKAGE - RESUBMITTAL
SD-1 PACKAGE - RESUBMITTAL
SD-1 PACKAGE - RESUBMITTAL - SITE LOCATIONS
8/15/2017
9/15/2017
12/5/2017
SD-2 PACKAGE 5/15/2018
DD-1 NON REVIEW 8/02/2018
DD-1 SUBMISSION 8/23/2018
DD-2 SUBMISSION 10/27/2018
CD-1 SUBMISSION 02/10/2019
CD-1 RE-SUBMISSION 04/12/2019
CD-1 RE-SUBMISSION 01/31/2020
CD-2 SUBMISSION 04/30/2020
CONSTRUCTION DOCUMENT SUBMISSION 06/29/2020
DN
FEC
FEC
GENERAL NOTES
BARRIER LEGEND
88 SF88 SF
HAC
205105 SF105 SF
OFFICE
105 SF105 SF
OFFICE
80 SF80 SF
ELEV.
ENCLOSED
STAIR
4560 SF4560 SF
OPEN OFFICE
75 SF75 SF
STOR./PRINT
53 SF53 SF
TOILET
EXTERIOR
STAIR
HVAC
CHASE
256 SF256 SF
BREAK ROOM
53 SF53 SF
TOILET
ROOF
130 SF130 SF
IT
105 SF105 SF
OFFICE
ELEV
EQUIP
ROOF
96 SF96 SF
STORAGE
STAIR
S1
TRAVEL DISTANCE: 107'-6"
TRAVEL DISTANCE: 104'-5"
105 SF105 SF
OFFICE
105 SF105 SF
OFFICE
ELECT
4560 SF4560 SF
OPEN OFFICE
CONF.
TRAVEL DISTANCE: 52' - 0"
OPEN TO BELOW
1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY. WALL PARTITION
DESIGNATIONS IDENTIFIED ON THIS DRAWING ARE FOR GRAPHICAL
PURPOSES ONLY AND MAY NOT REPRESENT THE ACTUAL WALL
CONSTRUCTION
2. REFER TO OTHER CONSULTANT/DISCIPLINE DRAWINGS FOR
ADDITIONAL DETAILS
3. ALL FIRE RATED PARTITIONS/ASSEMBLIES SHALL BE PERMANENTLY
IDENTIFIED BY STENCIL PAINTING - REFER TO SPECIFICATIONS FOR
DETAILS
4. REFER TO WALL PARTITION TYPE SCHEDULE /DRAWINGS FOR UL
DETAILS ASSOCIATED WITH THE PROJECT SCOPE OF WORK
LED EXIT LIGHT
PATH OF TRAVEL
SYMBOL LEGEND:
RATED WALL LEGEND:
ONE HOUR RATED WALL
X'-X"
EGRESS DIRECTIONAL ARROW
TRAVEL DISTANCE START CIRCLE
BUILDING DATA:
FIRE RESISTANT CONSTRUCTION/
FIREPROOFING SCHEDULE
ITEM REQUIRED RATING
-EXTERIOR WALLS:
LOAD BEARING
NON LOAD BEARING
-FIRE/PARTY WALLS
-SHAFTS
-OCCUPANCY SEPARATION
-INTERIOR WALLS:
LOAD BEARING
NON LOAD BEARING
-COLUMNS
-BEAMS
-FLOOR/CEILING
-ROOF/CEILING
-SMOKE WALLS
-CORRIDOR WALLS
0 HR
1 HR
1 HR
1 HR
1 HR
1 HR
-STAIR ENCLOSURES 1 HR
NET AREA:
FIRST FLOOR: 7,171.89 SF
SECOND FLOOR: 6,397.67 SF
TOTAL: 13,569.56 SF
GROSS AREA:
FIRST FLOOR: 7,553.63 GSF
SECOND FLOOR: 6,732.62 GSF
TOTAL: 14,286 GSF
0 HR
0 HR
0 HR
0 HR
0 HR
0 HR
0 HR
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
IMEG CORP. (M,E,P, & S)
300 NORTH LAKE AVENUE, 14TH FLOOR
PASADENA, CA 91101
CALIBRE ENGINEERING, INC. (CIVIL AND LANDSCAPE)
9090 SOUTH RIDGELINE BOULEVARD, SUITE 105
HIGHLANDS RANCH, CO 80129
KLEINFELDER (GEOTECH)
6700 KOLL CENTER PARKWAY
SUITE 120
PLEASANTON, CA 94566
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
BI
M
VI
SN
- M at he r S oc ia l S er vi ce s
Bu ild in g/
M at he r S oc ia l S er vi ce s
SD
2.
rv t
/4
/2
2:
:0
PM
SECOND FLOOR LIFE SAFETY PLAN
GC EM
CONSTRUCTION
DOCUMENT SUBMISSION
FULLY SPRINKLERED
612-163
GC102
DESIGN SOCIAL WORK AND
EXPAND CLINICAL SPACE
3551 Femoyer Street Mather, CA 95655
12/04/2020
1/8" = 1'-0"1 SECOND FLOOR PLAN LIFE SAFETY PLAN
SD-1 PACKAGE - ORIGINAL SUBMITTAL 5/24/2017
SD-1 PACKAGE - RESUBMITTAL
SD-1 PACKAGE - RESUBMITTAL
SD-1 PACKAGE - RESUBMITTAL - SITE LOCATIONS
8/15/2017
9/15/2017
12/5/2017
SD-2 PACKAGE 5/15/2018
DD-1 NON REVIEW 8/02/2018
DD-1 SUBMISSION 8/23/2018
DD-2 SUBMISSION 10/27/2018
CD-1 SUBMISSION 02/10/2019
CD-1 RE-SUBMISSION 04/12/2019
CD-1 RE-SUBMISSION 01/31/2020
CD-2 SUBMISSION 04/30/2020
CONSTRUCTION DOCUMENT SUBMISSION 06/29/2020
p p n
T
B p u t
E
U T
E
P N
P R
R C
V
A
M
A T
H E
R S
C
A D
D C
I V
I L
C
D
C
E
D
W G
P
M
FEMOYER STREET
P E
T E
R
A
M c C
U E
N
B L V
D
EXISTING CONDITIONS PLAN
BEM BEM
CE-100
EXISTING CONDITIONS PLAN
1" = 20'
SITE LEGEND
SITE NOTES
8/15/2017
9/15/2017
Drawing NumberLocation
Issue Date Checked Drawn
612-163DESIGN SOCIAL WORK AND
EXPAND CLINICAL SPACE
12/04/2020
Project Number
Building Number
Project TitleDrawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
Consultant:
FULLY SPRINKLERED
Romanyk Consulting Corp.www.romanykconsulting.com
3308 Preston Road, Suite 350-164, Plano, Texas 75093
Romanyk Consulting Focusing on what matters
SprinkleredCalibre
9090 South Ridgeline Boulevard, Suite 105
Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com
Construction Management Civil Engineering Surveying
Calibre Engineering, Inc.
A
B
C
D
E
F
321 4 5 6 7 8 9 10
CONSTRUCTION
DOCUMENT SUBMISSION
3551 Femoyer Street Mather, CA 95655
SD-1 PACKAGE - ORIGINAL SUBMITTAL
5/24/2017
SD-1 PACKAGE - RESUBMITTAL
SD-1 PACKAGE - RESUBMITTAL
SD-1 PACKAGE - RESUBMITTAL - SITE LOCATIONS
12/5/2017
SD-2 PACKAGE
5/15/2018
DD-1 NON REVIEW
8/02/2018
DD-1 SUBMISSION
8/23/2018
DD-2 SUBMISSION
10/27/2018
CD-1 SUBMISSION
02/10/2019
CD-1 RE-SUBMISSION
04/12/2019
CD-1 RE-SUBMISSION
01/31/2020
CD-2 SUBMISSION
04/30/2020
CONSTRUCTION DOCUMENT SUBMISSION
06/29/2020
REVIEW SET FOR CONSTRUCTION DOCUMENT SUBMISSION #2
09/24/2020
12/04/2020
CONSTRUCTION DOCUMENT SUBMISSION #2
BENCHMARK
DEMOLITION NOTES
ABBREVIATIONS
Gregory's iPad Pen
Gregory's iPad Pen
Gregory's iPad Pen p p n
T
B p u t
E
U T
E
P
R
M
A T
H E
R S
C
A D
D C
I V
I L
C
D
C
D
D
W G
P
M
FEMOYER STREET
P E
T E
R
A
M c C
U E
N
B L V
D
DEMOLITION AND EROSION
CONTROL PLAN
BEM BEM
CD-100
DEMOLITION AND EROSION
CONTROL PLAN
1" = 20'
SITE LEGEND
SITE NOTES
EROSION CONTROL LEGEND
8/15/2017
9/15/2017
Drawing NumberLocation
Issue Date Checked Drawn
612-163DESIGN SOCIAL WORK AND
EXPAND CLINICAL SPACE
12/04/2020
Project Number
Building Number
Project TitleDrawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
Consultant:
FULLY SPRINKLERED
Romanyk Consulting Corp.www.romanykconsulting.com
3308 Preston Road, Suite 350-164, Plano, Texas 75093
Romanyk Consulting Focusing on what matters
SprinkleredCalibre
9090 South Ridgeline Boulevard, Suite 105
Highlands Ranch, CO 80129 (303) 730-0434 www.calibre-engineering.com
Construction Management Civil Engineering Surveying
Calibre Engineering, Inc.
A
B
C
D
E
F
321 4 5 6 7 8 9 10
CONSTRUCTION
DOCUMENT SUBMISSION
3551 Femoyer Street Mather, CA 95655
SD-1 PACKAGE - ORIGINAL SUBMITTAL
5/24/2017