This is a Performance Specification document for the Tactical Radio Intermediate Test Set (TRITS), prepared by the Marine Corps Systems Command's Product Manager for Maintenance Support Systems in Quantico, Virginia, dated August 19, 2025.
The TRITS is a comprehensive test equipment system designed to diagnose and verify tactical radio systems. Key performance requirements include: operation from 120 Vrms single-phase 60Hz AC power; weight not exceeding 102 pounds with packaging in a single ruggedized transit case compliant with MIL-PRF-28800G; Class 3 environmental compliance per MIL-PRF-28800F covering temperature, humidity, altitude, vibration, and shock specifications. The system integrates extensive instrumentation including a digital multimeter (1 mV to 300 VDC/VAC, 0.1 Ohm to 30 MOhm), dual-channel 100 MHz oscilloscope with edge and pulse-width triggering, RF signal generator and receiver (1.5 MHz to 6 GHz with 1 Hz resolution), modulation capabilities (FM, AM, Phase, USB, LSB, and digital), audio frequency generators with dual sources, frequency counters, deviation meters, harmonic distortion meter, SINAD meter, vector signal analyzer with multiple QAM constellation support, bit error rate meter, RF power meter, and RF spectrum analyzer (1.5 MHz to 6 GHz, 100 dB display range). The system requires Windows 11 or DISA STIG-compliant operating system; integrated internal controller; 5 to 36 VDC programmable power supply (max 15 Amps); industry standard interfaces including ZIF connector, Ethernet, dual USB Type A, and antenna/T/R/SWR ports per MIL-STD-348B. Additional requirements specify 1,500-hour MTBF, built-in test with accessories, network connectivity, open-system architecture modularity for at least 30 percent of test instruments, duplex transmission/reception capability, non-subscription runtime environment with API for internal instrumentation communication, and maintenance logging including timestamp, serial numbers, test steps, results, and fault information. Verification occurs through field user evaluation with Marine operators and maintainers, bid sample testing using demonstration/examination/test methods, and source selection analysis of proposals.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CUI
Controlled by: MARCORSYSCOM Controlled by: PdM MSS PMM 151.4 CUI Category: CTI Distribution Statement: D POC: Tyler Adams, 704-962-2079
ATTACHMENT 1
TACTICAL RADIO INTERMEDIATE TEST SET
PERFORMANCE SPECIFICATION
19 August 2025
Prepared by:
Product Manager Maintenance Support Systems Marine Corps Systems Command
Quantico, VA 22134
Distribution Statement D: Distribution authorized to Department of Defense (DoD) and DoD contractors only; CTI; August 2025. Other requests for this document must be referred to Marine Corps Systems Command (Program Manager Combat Support Systems), 2200 Lester Street, Quantico, VA 22134-6050.
i
Tactical Radio Intermediate Test Set Performance Specification
Signature Page
Approved by:
Mr. Terry Ritchie Product Manager Product Manager Maintenance Support Systems ii
Table of Contents
1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5 PACKAGING
Tables
Table 1. Requirement/Verification Cross Reference Matrix
The Performance Specification (PSpec) identifies and establishes the requirements for the Tactical Radio Intermediate Test Set (TRITS).
1.1 Document Overview.
The TRITS is identified, described, and specified within this document in five major sections:
a. Section 1. Scope - Provides identification and a brief description of the purpose of the
TRITS
b. Section 2. Applicable Documents - Lists, by document number and title, all documents that form a part of the PSpec or are referenced by this PSpec
c. Section 3. Requirements - Gives the functional requirements of the TRITS
d. Section 4. Verification - Identifies the testing requirements to ensure compliance of all functional requirements defined in Section
e. Section 5. Packaging - Provides packaging requirements
The following documents of the exact issue shown form a part of this document to the extent specified herein. In the event of conflict between the documents referenced herein and the contents of this PSpec, the contents of this PSpec shall take precedence.
2.1 Government Documents.
MIL-PRF-28800G General Specification for Test Equipment for use with Electrical and Electronic Equipment
MIL-STD-130N Identification Marking of U.S. Military Property
MIL-STD-129R Military Marking for Shipment and Storage
MIL-STD-348B Department of Defense Interface Standard
MIL-STD-1472H Human Engineering
2.2 Non-Government Publications.
IPC J-STD-001J Requirements for Soldered Electrical and Electronic Assemblies
2.3 Availability of Documents.
Copies of Government documents are available online at http://quicksearch.dla.mil/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.
3.1 Environmental Requirements.
The Test Set shall conform to the Class 3 Environmental Requirements specified in Table 2 of MIL-PRF-28800F for the following:
a. Temperature, Not Operating
b. Temperature, Operating
c. Relative Humidity
d. Altitude, Not Operating
e. Vibration Limits
f. Shock, Functional
g. Bench Handling
3.2 Weight & Size.
a. The TRITS shall weigh no more than 102 pounds in accordance with the 2-person lift requirement in MIL-STD-1472H Table XLI
b. The TRITS shall fit in a single, ruggedized transit case that conforms to the requirements in MIL-PRF-28800G, Section 3.8
c. The TRITS shall meet the Means for Handling requirement in MIL-STD-1472H, Section 5.20.7.1
3.3 Power.
a. The TRITS shall operate off 120 Vrms single-phase 60Hz source
3.4 Instrumentation.
3.4.1 Digital Multimeter
a. Shall measure Volts DC with a range of 1 mV to 300 VDC
b. Shall measure Volts AC with a range of 1mV to 300 VAC
c. Shall measure Ohms with a range of 0.1 Ohm to 30 MOhm
d. Shall Measure Current DC and Current AC with a range of 0.01mA to 10A
3.4.2 Oscilloscope
a. Shall be dual channel
b. Bandwidth: 100 MHz
c. Trigger Capability
(1) Edge Trigger
(2) Pulse Width Trigger
3.4.3 Radio Frequency (RF) Signal Generator
a. Frequency Range: 1.5MHz to 6GHz
b. Frequency Resolution: 1Hz
3.4.4 RF Signal Modulation
3.4.4.1 FM Modulation
a. Carrier Range: 1.5MHz to 6000GHz
b. Deviation Range: 100Hz to +/- 100kHz
c. Deviation Rates: 20Hz to 20kHz
d. Resolution: 1Hz
3.4.4.2 AM Modulation
a. Carrier Range: 1.5MHz to 6000GHz
b. Deviation Range: 100Hz to +/- 100kHz
c. Deviation Rates: 20Hz to 20kHz
d. Resolution: 1Hz
3.4.4.3 Phase Modulation
a. Carrier Range: 1.5MHz to 6000GHz
b. Deviation Range: 0 to 100 rads
c. Deviation Rates: 20Hz to 20kHz
d. Resolution: 0.1 rads
3.4.5 Upper Sideband (USB) & Lower Sideband (LSB)
a. Shall be able to transmit a USB modulated signal
b. Shall be able to transmit an LSB modulated signal
3.4.6 Digital Modulation
a. Shall provide the ability to create waveforms to be used as a modulation source
b. Shall provide the ability to record waveforms
c. Shall provide the ability to add additional IQ files to the TRITS via an external drive
3.4.7 RF Signal Receiver
a. Frequency Range: 1.5MHz to 6GHz
b. Resolution: 1Hz
c. Instantaneous IF Bandwidth: 10MHz
3.4.8 Audio Frequency Generator (AFG)
a. Shall provide two AFG sources
b. Frequency Range: 20Hz to 20kHz
c. Frequency Resolution: 0.1Hz
d. Waveforms:
(1) Sine Wave
(2) Square Wave
e. Two BNC Audio Input/Output Ports
3.4.9 Frequency Counter and Frequency Error Meter
a. Frequency Range: 1.5MHz to 6GHz
b. Resolution: 1Hz
3.4.10 Audio Frequency Counter
a. Frequency Range: 20Hz to 20kHz
b. Resolution: 1Hz
3.4.11 Frequency Modulation Deviation Meter
a. Range: 0Hz to 100kHz
b. Resolution: 1Hz
c. Modulation Rate Range: 20Hz to 20kHz
d. Measurement Type: Peak+, Peak-
3.4.12 Amplitude Modulation Meter
a. Range: 0% to 100%
b. Resolution: 1%
c. Modulation Rate Range: 20Hz to 20kHz
d. Measurement Type: Peak+, Peak-
3.4.13 Harmonic Distortion Meter
a. Range: 0.1% to 50%
b. Resolution: 0.1%
c. Frequency Range: 20Hz to 20kHz
3.4.14 SINAD Meter
a. Range: 0dB to 40dB
b. Resolution: 1dB
c. Frequency Range: 20Hz to 20kHz
3.4.15 Phase Modulation Deviation Meter
a. Range: 0 rad to 100 rad
b. Resolution: 0.1 rad
c. Frequency Range: 20Hz to 20kHz
d. Measurement Type: Peak+, Peak-
3.4.16 Vector Signal Analyzer
a. Range: 1.5MHz to 6GHz
b. Modulation Bandwidth: 10MHz
c. Constellation Diagram:
(1) 8QAM
(2) 16QAM
(3) 32QAM
(4) 64QAM
(5) 128QAM
(6) 256QAM
3.4.17 Built-In Test (BIT) Error Rate Meter
a. Style: Decodes Non-Return to Zero (NRZ) style data
b. Range: 1 x 10-1 to 1 x 10-5
3.4.18 RF Power Meter
a. Frequency Range: 1.5MHz to 6GHz
b. Resolution
(1) 0.1db
(2) 0.1W
c. Power Measurement
(1) Absolute
(2) Relative
d. Measurement Type
(1) Average
(2) Peak
3.4.19 RF Spectrum Analyzer
a. Frequency Range: 1.5MHz to 6GHz
b. Frequency Span: 1kHz/Div to full rf span
c. Display Range: 100dB
d. Resolution Bandwidth
(1) <= 100Hz to >= 1MHz
(2) <= 300Hz to >= 3MHz
e. Marker Functions
(1) Peak
(2) Delta
3.4.20 Internal Reference Oscillator
a. Clock Speed: 10MHz
b. Accuracy: 0.01 ppm/year
3.5 Interface
a. Industry Standard Communication Interface for:
(1) Controls and Peripherals
(2) Instrumentation
b. ZIF Connector 168 Pin
c. Ethernet
d. Two USB Type A
e. Antenna Port, shall conform to the requirements in MIL-STD-348B
f. T/R Port, shall conform to the requirements in MIL-STD-348B
g. SWR Port, shall conform to the requirements in MIL-STD-348B
3.6 Controller
a. The system controller shall be integrated and internal to TRITS system
b. The system shall be Windows 11 or an operating system that is configurable to be compliant with a Defense Information Systems Agency (DISA) Security Technical Implementation Guide (STIG)
3.7 Power Supply
a. 5 to 36 VDC Source
b. Max 15 Amps DC
c. Shall be programmable and controllable by the integrated system controller
3.8 Graphical User Interface
a. Shall provide a graphical user interface that allows access to stimulus and measurement functions
b. Shall provide the ability to view multiple instruments simultaneously
3.9 Runtime
a. Shall include a non-subscription based runtime environment for Test Program Set (TPS) development
b. Shall provide an Application Program Interface (API) that allows for communication of all TRITS internal instrumentation hardware
c. The runtime environment is user-friendly
3.10 Mean-Time Between Failure (MTBF)
a. TRITS shall have an MTBF of 1500 hours
3.11 Maintenance
a. The TRITS shall provide the capability to record and report TPS information, including fault data, to facilitate maintenance and repair. The report shall be capable of providing:
Timestamp
System Serial Number
Unit Under Test (UUT) Serial Number
Test Step
Test Step Result
Fault Information
3.12 Built-In Test
a. The TRITS shall include a BIT that verifies, at a minimum, power and communication of all internal instrumentation hardware
b. Necessary accessories for BIT shall be included and reside in the TRITS transit case
3.13 Network Connectivity
a. The TRITS shall have either an ethernet port or wireless capability to allow for the TRITS to be configured to connect to the Marine Corps Enterprise Network
3.14 Modularity
a. The TRITS shall utilize open system architecture and modularity (e.g., PXI, PXIe, etc.)
for at least 30% of the following test instrumentation:
RF Signal Generator / Receiver
Digital Oscilloscope
Audio Frequency Generator
Audio Frequency Counter
Frequency Counter and Frequency Error Meter
Frequency Modulation Deviation Meter
Amplitude Modulation Meter
Harmonic Distortion Meter
SINAD Meter
Phase Modulation Deviation Meter
Vector Signal Analyzer
BIT Error Rate Meter
RF Power Meter
RF Spectrum Analyzer
3.15 Duplex
a. The TRITS shall be capable of transmitting and receiving at the same time
4.1 Classification of Inspections.
Inspection requirements are classified as follows:
a. Validation and Verification Inspection (see 4.3)
b. Acceptance Test (see 4.4)
4.2 Methods of Inspection.
Methods used to accomplish verification shall include:
4.2.1 Analysis. An element of verification that utilizes established technical or mathematical models or simulations, algorithms, charts, graphs, circuit diagrams, or other scientific principles and procedures to provide evidence that stated requirements were met.
4.2.2 Demonstration. An element of verification which denotes the actual operation, adjustment, or re-configuration of items to provide evidence that the designed functions were accomplished under specific scenarios. The items may be instrumented and quantitative limits of performance monitored.
4.2.3 Examination / Inspection. An element of verification and inspection consisting of investigation, without use of special laboratory appliances or procedures, of items to determine conformance to those specified requirements which can be determined by such investigations.
Examination is generally nondestructive and typically includes the use of sight, hearing, smell, touch, and taste; simple physical manipulation; mechanical and electrical gauging and measurement; and other forms of investigation.
4.2.4 Test. An element of verification and inspection which generally denotes the determination, by technical means, of the properties or elements of items, including functional operation, and involves the application of established scientific principles and procedures and conditions to verify compliance with requirements.
4.3 Field User Evaluation (FUE) / Bid Sample Test.
The FUE shall consist of an event where Marine operators and maintainers will assess the Request for Proposal (RFP) Bid submissions and complete surveys which will be utilized for evaluation. Additionally, the event will include a Bid Sample Test which will consist of evaluating the performance specifications in Table 1 by following the verification strategy. This will consist of Demonstration, Examination/Inspection, and Test cases.
4.4 Source Selection.
This verification shall consist of analysis of paper proposals to verify the performance specifications in Table 1.
Table 1. Requirement/Verification Cross Reference Matrix
REQUIREMENT/VERIFICATION CROSS REFERENCE MATRIX
METHOD OF VERIFICATION CLASSES OF VERIFICATION
N/A - NOT APPLICABLE 1 - Field User Evaluation / Bid Sample Test A - ANALYSIS 2 - Source Selection D - DEMONSTRATION C - Completed
E - EXAMINATION
T - TEST
Sec. 3 Requirements Title Method of Verification Verification Class
Verification Strategy N/A A D E T 1 C 2 C
3.1 Environmental Requirements
3.1.a Temperature, Not Operating X X The vendors will be required to submit Environmental Test Data as part of the RFP which will be analyzed to ensure the requirement is met.
3.1.b Temperature, Operating X X The vendors will be required to submit Environmental Test Data as part of the RFP which will be analyzed to ensure the requirement is met.
3.1.c Relative Humidity X X The vendors will be required to submit Environmental Test Data as part of the RFP which will be analyzed to ensure the requirement is met.
3.1.d Altitude, Not Operating X X The vendors will be required to submit Environmental Test Data as part of the RFP which will be analyzed to ensure the requirement is met.
3.1.e Vibration Limits X X The vendors will be required to submit Environmental Test Data as part of the RFP which will be analyzed to ensure the requirement is met.
3.1.f Shock, Functional X X The vendors will be required to submit Environmental Test Data as part of the RFP which will be analyzed to ensure the requirement is met.
3.1.g Bench Handling X X The vendors will be required to submit Environmental Test Data as part of the RFP which will be analyzed to ensure the requirement is met.
3.2 Weight & Size
3.2.a Weight X X The systems submitted as part of the RFP will be weighed during the FUE/Bid Sample Test event prior to Source Selection.
REQUIREMENT/VERIFICATION CROSS REFERENCE MATRIX
METHOD OF VERIFICATION CLASSES OF VERIFICATION
N/A - NOT APPLICABLE 1 - Field User Evaluation / Bid Sample Test A - ANALYSIS 2 - Source Selection D - DEMONSTRATION C - Completed
E - EXAMINATION
T - TEST
Sec. 3 Requirements Title Method of Verification Verification Class
Verification Strategy N/A A D E T 1 C 2 C
3.2.b Test Set Transit Case X X
The systems submitted as part of the RFP will be examined to ensure the test sets are packaged in their own respective single transit case.
Additionally, section 3.8 of MIL-PRF-28800G will be verified through inspection at the Bid Sample Test.
3.2.c Means for Handling X The TRITS will be inspected/examined to ensure that it can be carried in line with the MIL-STD-1472H Section 5.20.7.1.
3.3 Power
3.3.a Source X X The systems will be plugged into a 120 Vrms single-phase 60Hz source at the FUE/Bid Sample Test to ensure the system properly operates.
3.4 Instrumentation
3.4.1 Digital Multimeter
3.4.1.a Volts DC X X X X
The Digital Multimeter will be utilized during the FUE/Bid Sample Test event prior to Source Selection. The ability to measure Volts DC will be demonstrated by using an external system to route power to the TRITS. The Range will be verified during Source Selection by analyzing the product specification.
3.4.1.b Volts AC X X X X
The Digital Multimeter will be utilized during the FUE/Bid Sample Test event prior to Source Selection. The ability to measure Volts AC will be demonstrated by using an external system to route power to the TRITS. The Range will be verified during Source Selection by analyzing the product specification.
3.4.1.c Ohms X X X X
The Digital Multimeter will be utilized during the FUE/Bid Sample Test event prior to Source Selection. The ability to measure Ohms will be demonstrated by using an external system to route power to the TRITS. The Range will be verified during Source Selection by analyzing the product specification.
REQUIREMENT/VERIFICATION CROSS REFERENCE MATRIX
METHOD OF VERIFICATION CLASSES OF VERIFICATION
N/A - NOT APPLICABLE 1 - Field User Evaluation / Bid Sample Test A - ANALYSIS 2 - Source Selection D - DEMONSTRATION C - Completed
E - EXAMINATION
T - TEST
Sec. 3 Requirements Title Method of Verification Verification Class
Verification Strategy N/A A D E T 1 C 2 C
3.4.1.d Current X X X X
The Digital Multimeter will be utilized during the FUE/Bid Sample Test event prior to Source Selection. The ability to measure AC and DC Current will be demonstrated by using an external system to route power to the TRITS. The Range will be verified during Source Selection by analyzing the product specification.
3.4.2 Oscilloscope
3.4.2.a Dual Channel X X The TRITS will be inspected to ensure there are a minimum of two channels for the Oscilloscope.
3.4.2.b Bandwidth X X The product specification delivered as part of the proposal will be evaluated to ensure the Oscilloscope bandwidth is at least 100 MHz.
3.4.2.c Trigger Capability
3.4.2.c.1 Edge Trigger X X The Edge Trigger capability will be demonstrated at the FUE/Bid Sample Test by receiving an RF signal and analyzing it with an edge trigger.
3.4.2.c.2 Pulse Width Trigger X X The Pulse Width capability will be demonstrated at the FUE/Bid Sample Test by receiving an RF signal and analyzing it with a pulse width trigger.
3.4.3 RF Signal Generator
3.4.3.a Frequency Range X X The TRITS will be set up to output 1.5MHz and 6GHz to an external spectrum analyzer to ensure that the TRITS can produce low/high end of the spectrum.
3.4.3.b Frequency Resolution X X It will be verified that the TRITS RF Sig Gen can accept a frequency of tolerance 1Hz and output the frequency to an external spectrum analyzer to ensure it can produce that frequency.
3.4.4 RF Signal Modulation
3.4.4.1 FM Modulation
3.4.4.1.a Carrier Range X X X The TRITS will be inspected to ensure that the instrumentation GUI can be set to the carrier range. An external spectrum analyzer will be utilized to receive an outputted FM modulated signal from the TRITS.
REQUIREMENT/VERIFICATION CROSS REFERENCE MATRIX
METHOD OF VERIFICATION CLASSES OF VERIFICATION
N/A - NOT APPLICABLE 1 - Field User Evaluation / Bid Sample Test A - ANALYSIS 2 - Source Selection D - DEMONSTRATION C - Completed
E - EXAMINATION
T - TEST
Sec. 3 Requirements Title Method of Verification Verification Class
Verification Strategy N/A A D E T 1 C 2 C
It will be verified that the carrier range lower/upper limits on the external spectrum analyzer match that of the settings on the TRITS.
3.4.4.1.b Deviation Range X X X
The TRITS will be inspected to ensure that the instrumentation GUI can be set to the deviation range. An external spectrum analyzer will be utilized to receive an outputted FM modulated signal from the TRITS. It will be verified that the deviation range lower/upper limits on the external spectrum analyzer match that of the settings on the
TRITS.
3.4.4.1.c Deviation Rates X X X
The TRITS will be inspected to ensure that the instrumentation GUI can be set to the deviation rates. An external spectrum analyzer will be utilized to receive an outputted FM modulated signal from the TRITS.
It will be verified that the deviation rates lower/upper limits on the external spectrum analyzer match that of the settings on the TRITS.
3.4.4.1.d Resolution X X X
The TRITS will be inspected to ensure that the instrumentation GUI can be set to the resolution. An external spectrum analyzer will be utilized to receive an outputted FM modulated signal from the TRITS.
It will be verified that the signal has a 1Hz resolution.
3.4.4.2 AM Modulation
3.4.4.2.a Carrier Range X X X
The TRITS will be inspected to ensure that the instrumentation GUI can be set to the carrier range. An external spectrum analyzer will be utilized to receive an outputted AM modulated signal from the TRITS.
It will be verified that the carrier range lower/upper limits on the external spectrum analyzer match that of the settings on the TRITS.
3.4.4.2.b Deviation Range X X X
The TRITS will be inspected to ensure that the instrumentation GUI can be set to the deviation range. An external spectrum analyzer will be utilized to receive an outputted AM modulated signal from the TRITS. It will be verified that the deviation range lower/upper limits on the external spectrum analyzer match that of the settings on the
TRITS.
REQUIREMENT/VERIFICATION CROSS REFERENCE MATRIX
METHOD OF VERIFICATION CLASSES OF VERIFICATION
N/A - NOT APPLICABLE 1 - Field User Evaluation / Bid Sample Test A - ANALYSIS 2 - Source Selection D - DEMONSTRATION C - Completed
E - EXAMINATION
T - TEST
Sec. 3 Requirements Title Method of Verification Verification Class
Verification Strategy N/A A D E T 1 C 2 C
3.4.4.2.c Deviation Rates X X X
The TRITS will be inspected to ensure that the instrumentation GUI can be set to the deviation rates. An external spectrum analyzer will be utilized to receive an outputted AM modulated signal from the TRITS.
It will be verified that the deviation rates lower/upper limits on the external spectrum analyzer match that of the settings on the TRITS.
3.4.4.2.d Resolution X X X
The TRITS will be inspected to ensure that the instrumentation GUI can be set to the resolution. An external spectrum analyzer will be utilized to receive an outputted AM modulated signal from the TRITS.
It will be verified that the signal has a resolution of 1Hz.
3.4.4.3 Phase Modulation
3.4.4.3.a Carrier Range X X X
The TRITS will be inspected to ensure that the instrumentation GUI can be set to the carrier range. An external spectrum analyzer will be utilized to receive an outputted Phase Modulated signal from the TRITS. It will be verified that the carrier range lower/upper limits on the external spectrum analyzer match that of the settings on the TRITS.
3.4.4.3.b Deviation Range X X X
The TRITS will be inspected to ensure that the instrumentation GUI can be set to the deviation range. An external spectrum analyzer will be utilized to receive an outputted phase modulated signal from the TRITS. It will be verified that the deviation range lower/upper limits on the external spectrum analyzer match that of the settings on the
TRITS.
3.4.4.3.c Deviation Rates X X X
The TRITS will be inspected to ensure that the instrumentation GUI can be set to the deviation rates. An external spectrum analyzer will be utilized to receive an outputted phase modulated signal from the TRITS. It will be verified that the deviation rates lower/upper limits on the external spectrum analyzer match that of the settings on the TRITS.
3.4.4.3.d Resolution X X X
The TRITS will be inspected to ensure that the instrumentation GUI can be set to the resolution. An external spectrum analyzer will be utilized to receive an outputted phase modulated signal from the TRITS. It will be verified that the signal has a 0.1 rads resolution.
REQUIREMENT/VERIFICATION CROSS REFERENCE MATRIX
METHOD OF VERIFICATION CLASSES OF VERIFICATION
N/A - NOT APPLICABLE 1 - Field User Evaluation / Bid Sample Test A - ANALYSIS 2 - Source Selection D - DEMONSTRATION C - Completed
E - EXAMINATION
T - TEST
Sec. 3 Requirements Title Method of Verification Verification Class
Verification Strategy N/A A D E T 1 C 2 C
3.4.5 USB & LSB
3.4.5.a USB X X X
The TRITS will be inspected to ensure that the instrumentation GUI can be set to produce a USB waveform. An external spectrum analyzer will be utilized to read an outputted USB signal from the TRITS. It will be verified that the USB signal matches that of the settings on the
TRITS.
3.4.5.b LSB X X X
The TRITS will be inspected to ensure that the instrumentation GUI can be set to produce an LSB waveform. An external spectrum analyzer will be utilized to read an outputted USB signal from the TRITS. It will be verified that the LSB signal matches that of the settings on the TRITS.
3.4.6 Digital Modulation
3.4.6.a Create Modulation Source X X The ability to create a waveform to be used as a modulation source will be demonstrated. An external spectrum analyzer will be utilized to receive the outputted waveform from the TRITS.
3.4.6.b Record Waveform X X The ability to record a waveform will be demonstrated. An external system will be utilized to generate an RF waveform that is sent to the TRITS receiver and recorded.
3.4.6.c Add IQ Files X X The TRITS will be inspected to ensure the ability to add IQ files to the system is available. This could be an option in the GUI or the ability to add external files to a file directory in which IQ files are loaded.
3.4.7 RF Signal Receiver
3.4.7.a Frequency Range X X
The ability to receive the low/high end of the frequency range will be demonstrated. An external system will be utilized to generate waveforms to send to the TRITS RF receiver. The TRITS spectrum analyzer will be utilized to visualize the waveform to verify the frequency range.
REQUIREMENT/VERIFICATION CROSS REFERENCE MATRIX
METHOD OF VERIFICATION CLASSES OF VERIFICATION
N/A - NOT APPLICABLE 1 - Field User Evaluation / Bid Sample Test A - ANALYSIS 2 - Source Selection D - DEMONSTRATION C - Completed
E - EXAMINATION
T - TEST
Sec. 3 Requirements Title Method of Verification Verification Class
Verification Strategy N/A A D E T 1 C 2 C
3.4.7.b Resolution X X
The ability to receive a signal that has a resolution of 1 Hz will be demonstrated. An external system will be utilized to generate waveforms with 1Hz resolution to send to the TRITS RF receiver. The TRITS spectrum analyzer will be utilized with 1Hz resolution to visualize the waveform to verify the signal peak.
3.4.7.c Instantaneous IF Bandwidth X X Verification will occur through analysis of proposals. It will be verified that instrumentation data sheets meet the requirement.
3.4.8 Audio Frequency Generator
3.4.8.a Dual Source X X The TRITS will be inspected to ensure there are dual audio frequency sources/ports.
3.4.8.b Frequency Range X X X
The TRITS will be inspected to ensure that the AFG GUI can be set to the lower/upper frequency range. An external spectrum analyzer will be utilized to receive an outputted signal form the TRITS AFG. It will be verified that the signal peak matches that of the outputted frequency.
3.4.8.c Frequency Resolution X X X
The TRITS will be inspected to ensure that the AFG GUI can be set to 1 Hz resolution. An external spectrum analyzer will be utilized to receive an outputted signal from the TRITS AFG that is set to 1Hz resolution. It will be verified that the signal peak matches that of the outputted frequency.
3.4.8.d Waveforms
3.4.8.d.1 Sine Wave X X X
The TRITS will be inspected to ensure that the AFG GUI offers the ability to select a sine wave to be produced. It will be demonstrated that a sine wave can be produced by transmitting a sine wave to an external spectrum analyzer. The spectrum analyzer will be utilized to visualize the waveform to ensure it is a sine wave.
REQUIREMENT/VERIFICATION CROSS REFERENCE MATRIX
METHOD OF VERIFICATION CLASSES OF VERIFICATION
N/A - NOT APPLICABLE 1 - Field User Evaluation / Bid Sample Test A - ANALYSIS 2 - Source Selection D - DEMONSTRATION C - Completed
E - EXAMINATION
T - TEST
Sec. 3 Requirements Title Method of Verification Verification Class
Verification Strategy N/A A D E T 1 C 2 C
3.4.8.d.2 Square Wave X X X
The TRITS will be inspected to ensure that the AFG GUI offers the ability to select a square wave to be produced. It will be demonstrated that a square wave can be produced by transmitting a square wave to an external spectrum analyzer. The spectrum analyzer will be utilized to visualize the waveform to ensure it is a square wave.
3.4.8.e BNC Audio Input/Output Ports
X X The TRITS will be inspected to ensure it has two audio input/output ports.
3.4.9 Frequency Counter and Frequency Error Meter
3.4.9.a Frequency Range X X
It will be demonstrated that the TRITS can receive a signal, from an external system, at the lower/upper end of the frequency range. It will be verified that the TRITS displays the same frequency as the external RF Generator.
3.4.9.b Resolution X X It will be demonstrated that the TRITS can receive a signal from an external system and display it at a 1 Hz resolution.
3.4.10 Audio Frequency Counter
3.4.10.a Frequency Range X X
It will be demonstrated that the TRITS Audio Frequency Counter can receive a signal from an external system at the lower/upper end of the frequency range. It will be verified that the TRITS displays the same frequency as the external RF Generator.
3.4.10.b Resolution X X It will be demonstrated that the TRITS Audio Frequency Counter can receive a signal from an external system and display it at a 1 Hz resolution.
3.4.11 Frequency Modulation Deviation Meter
3.4.11.a Range X X The product specification will be analyzed to verify the FM Deviation Meter range.
3.4.11.b Resolution X X It will be demonstrated that the TRITS FM Deviation Meter can receive a FM signal from an external system and display the frequency modulation deviation at a 1 Hz frequency.
REQUIREMENT/VERIFICATION CROSS REFERENCE MATRIX
METHOD OF VERIFICATION CLASSES OF VERIFICATION
N/A - NOT APPLICABLE 1 - Field User Evaluation / Bid Sample Test A - ANALYSIS 2 - Source Selection D - DEMONSTRATION C - Completed
E - EXAMINATION
T - TEST
Sec. 3 Requirements Title Method of Verification Verification Class
Verification Strategy N/A A D E T 1 C 2 C
3.4.11.c Modulation Rate Range X X It will be demonstrated that the TRITS FM Deviation Meter can receive a signal from an external system at the lower/upper end of the frequency range and display its deviation.
3.4.11.d Measurement Type X X The TRITS FM Deviation Meter will be inspected and it will be ensured that it has a Peak+ and Peak- measurement type capability.
3.4.12 Amplitude Modulation Meter
3.4.12.a Range X X The product specification will be analyzed to verify the AM Modulation Meter range.
3.4.12.b Resolution X X It will be demonstrated that the TRITS AM Modulation Meter can receive an AM signal from an external system and display the amplitude modulation at a 1% resolution.
3.4.12.c Modulation Rate Range X X It will be demonstrated that the TRITS AM Modulation Meter can receive a signal from an external system at the lower/upper end of the frequency range and display its modulation percent.
3.4.12.d Measurement Type X X The TRITS AM Modulation Meter will be inspected and it will be ensured that it has a Peak+ and Peak- measurement type capability.
3.4.13 Harmonic Distortion Meter
3.4.13.a Range X X The product specification will be analyzed to verify the Harmonic Distortion Meter range.
3.4.13.b Resolution X X It will be demonstrated that the TRITS Harmonic Distortion Meter can receive a signal generated by an external system and display the harmonic distortion with a resolution of 0.1%.
3.4.13.c Frequency Range X X It will be demonstrated that the TRITS Harmonic Distortion meter can receive a signal generated by an external system at the lower/upper end of the frequency range and display its harmonic distortion.
3.4.14 SINAD Meter
3.4.14.a Range X X The product specification will be analyzed to verify the SINAD Meter range.
REQUIREMENT/VERIFICATION CROSS REFERENCE MATRIX
METHOD OF VERIFICATION CLASSES OF VERIFICATION
N/A - NOT APPLICABLE 1 - Field User Evaluation / Bid Sample Test A - ANALYSIS 2 - Source Selection D - DEMONSTRATION C - Completed
E - EXAMINATION
T - TEST
Sec. 3 Requirements Title Method of Verification Verification Class
Verification Strategy N/A A D E T 1 C 2 C
3.4.14.b Resolution X X It will be demonstrated that the TRITS SINAD Meter can receive a signal generated by an external system and display the SINAD at a 1dB resolution.
3.4.14.c Frequency Range X X It will be demonstrated that the TRITS SINAD Meter can receive a signal generated by an external system at the lower/upper end of the frequency range and display its SINAD.
3.4.15 Phase Modulation Deviation Meter
3.4.15.a Range X X The product specification will be analyzed to verify the Phase Modulation Deviation Meter range.
3.4.15.b Resolution X X It will be demonstrated that the TRITS Phase Modulation Deviation Meter can receive a signal generated by an external system and display the Phase Modulation Deviation with a resolution of 0.1 rad.
3.4.15.c Frequency Range X X
It will be demonstrated that the TRITS Phase Modulation Deviation Meter can receive a signal generated by an external system at the lower/upper end of the frequency range and display its phase modulation deviation.
3.4.15.d Measurement Type X X The TRITS Phase Modulation Deviation Meter will be inspected and it will be ensured that it has a Peak+ and Peak- measurement type capability.
3.4.16 Vector Signal Analyzer
3.4.16.a Range X X
It will be demonstrated that the TRITS Vector Signal Analyzer can receive a signal generated by an external system at the lower/upper end of the frequency range. It will be ensured that the peak of the visualized signal matches that of the signal generated by the external system.
3.4.16.b Modulation Bandwidth X X
It will be demonstrated that the TRITS Vector Signal Analyzer can receive a signal generated by an external system that has 10MB bandwidth of data on the signal. It will be ensured that the signal is visualized and that the 10MB shelf is verified.
REQUIREMENT/VERIFICATION CROSS REFERENCE MATRIX
METHOD OF VERIFICATION CLASSES OF VERIFICATION
N/A - NOT APPLICABLE 1 - Field User Evaluation / Bid Sample Test A - ANALYSIS 2 - Source Selection D - DEMONSTRATION C - Completed
E - EXAMINATION
T - TEST
Sec. 3 Requirements Title Method of Verification Verification Class
Verification Strategy N/A A D E T 1 C 2 C
3.4.16.c Constellation Diagram
3.4.16.c.1 8QAM X X The TRITS VSA will be inspected to ensure that the 8QAM constellation diagram is supported and selectable.
3.4.16.c.2 16QAM X X The TRITS VSA will be inspected to ensure that the 16QAM constellation diagram is supported and selectable.
3.4.16.c.3 32QAM X X The TRITS VSA will be inspected to ensure that the 32QAM constellation diagram is supported and selectable.
3.4.16.c.4 64QAM X X The TRITS VSA will be inspected to ensure that the 64QAM constellation diagram is supported and selectable.
3.4.16.c.5 128QAM X X The TRITS VSA will be inspected to ensure that the 128QAM constellation diagram is supported and selectable.
3.4.16.c.6 256QAM X X The TRITS VSA will be inspected to ensure that the 256QAM constellation diagram is supported and selectable.
3.4.17 Bit Error Rate Meter
3.4.17.a Style X X X X
The product specifications that are submitted as part of the proposal will be analyzed to ensure non-return to zero data is supported. The functionality of the Bit Error Rate (BER) Meter will be demonstrated by utilizing an external system to generate a waveform and transmit it to the TRITS BER Meter. Errors will be induced by starting and stopping the waveform to see if the percent error changes.
3.4.17.b Range X X X X
The product specifications that are submitted as part of the proposal will be analyzed to ensure the range specification. The functionality of the BER Meter will be demonstrated by utilizing an external system to generate a waveform and transmit it to the TRITS BER Meter. Errors will be induced by starting and stopping the waveform to see if the percent error changes.
3.4.18 RF Power Meter
3.4.18.a Frequency Range X X It will be demonstrated that the TRITS RF Power Meter can receive a signal generated by an external system at the lower/upper end of the frequency range and display its power.
REQUIREMENT/VERIFICATION CROSS REFERENCE MATRIX
METHOD OF VERIFICATION CLASSES OF VERIFICATION
N/A - NOT APPLICABLE 1 - Field User Evaluation / Bid Sample Test A - ANALYSIS 2 - Source Selection D - DEMONSTRATION C - Completed
E - EXAMINATION
T - TEST
Sec. 3 Requirements Title Method of Verification Verification Class
Verification Strategy N/A A D E T 1 C 2 C
3.4.18.b Resolution
3.4.18.b.1 dB X X It will be demonstrated that the TRITS RF Power Meter can receive a signal generated by an external system and display its power in dB.
3.4.18.b.2 W X X It will be demonstrated that the TRITS RF Power Meter can receive a signal generated by an external system and display its power in Watts.
3.4.18.c Power Measurement
3.4.18.c.1 Absolute X X It will be demonstrated that the TRITS RF Power Meter can receive a signal generated by an external system and display its absolute power measurement.
3.4.18.c.2 Relative X X It will be demonstrated that the TRITS RF Power Meter can receive a signal generated by an external system and display its relative power measurement.
3.4.18.d Measurement Type
3.4.18.d.1 Average X X It will be demonstrated that the TRITS RF Power Meter can receive a signal generated by an external system and display its average power.
3.4.18.d.2 Peak X X It will be demonstrated that the TRITS RF Power Meter can receive a signal generated by an external system and display its peak power.
3.4.19 RF Spectrum Analyzer
3.4.19.a Frequency Range X X
It will be demonstrated that the TRITS Spectrum Analyzer can receive a signal generated by an external system at the lower/upper end of the frequency range and display its waveform. It will be ensured that the peak of the waveform matches that of the frequency set on the external RF generator.
3.4.19.b Frequency Span X X It will be demonstrated that the TRITS Spectrum Analyzer frequency span can be set as low as 1kHz/Div to the entire waveform spectrum.
3.4.19.c Display Range X X It will be demonstrated that the TRITS Spectrum Analyzer display range can be set to at least 100dB.
3.4.19.d Resolution Bandwidth
REQUIREMENT/VERIFICATION CROSS REFERENCE MATRIX
METHOD OF VERIFICATION CLASSES OF VERIFICATION
N/A - NOT APPLICABLE 1 - Field User Evaluation / Bid Sample Test A - ANALYSIS 2 - Source Selection D - DEMONSTRATION C - Completed
E - EXAMINATION
T - TEST
Sec. 3 Requirements Title Method of Verification Verification Class
Verification Strategy N/A A D E T 1 C 2 C
3.4.19.d.1 X X It will be demonstrated that the TRITS Spectrum Analyzer resolution bandwidth can be set to <=100Hz to >= 1MHz.
3.4.19.d.2 X X It will be demonstrated that the TRITS Spectrum Analyzer resolution bandwidth can be set to <=300Hz to >= 3MHz.
3.4.19.e Marker Functions
3.4.19.e.1 Peak X X It will be demonstrated that the TRITS Spectrum Analyzer marker can be set to Peak and display the peak of a waveform.
3.4.19.e.2 Delta X X It will be demonstrated that the TRITS Spectrum Analyzer marker can be set to Delta and display the frequency/amplitude difference between a reference mark and delta mark.
3.4.20 Internal Reference Oscillator
3.4.20.a Clock Speed X X The product specification will be analyzed to ensure that clock speed meets the 10Mhz requirement.
3.4.20.b Accuracy X X The product specification will be analyzed to ensure the accuracy is
0.01 ppm/year.
3.5 Interface
3.5.a Industry Standard
3.5.a.1 Controls and Peripherals X X X X The TRITS will be inspected to identify all controls and peripherals.
The product specifications will be analyzed to ensure that controls and peripherals are in line with industry standards.
3.5.a.2 Instrumentation X X The product specification will be analyzed to ensure that internal instrumentation interfaces adhere to industry standards.
3.5.b ZIF Connector X X The TRITS will be inspected to ensure it has a ZIF Connector with 168-pin.
3.5.c Ethernet X X The TRITS will be inspected to ensure it has an ethernet port.
3.5.d USB X X The TRITS will be inspected to ensure it has two USB ports.
REQUIREMENT/VERIFICATION CROSS REFERENCE MATRIX
METHOD OF VERIFICATION CLASSES OF VERIFICATION
N/A - NOT APPLICABLE 1 - Field User Evaluation / Bid Sample Test A - ANALYSIS 2 - Source Selection D - DEMONSTRATION C - Completed
E - EXAMINATION
T - TEST
Sec. 3 Requirements Title Method of Verification Verification Class
Verification Strategy N/A A D E T 1 C 2 C
3.5.e Antenna Port X X X X The TRITS will be inspected to ensure it has one Antenna port. It will be verified that the port complies with MIL-STD-348B by analyzing the product specification.
3.5.f T/R Port X X X X The TRITS will be inspected to ensure it has one T/R Port. It will be verified that the port complies with MIL-STD-348B by analyzing the product specification.
3.5.g SWR X X X X The TRITS will be inspected to ensure it has one SWR port. It will be verified that the port complies with MIL-STD-348B by analyzing the product specification.
3.6 Controller
3.6.a Integration X X The TRITS will be inspected to ensure the system controller is integrated into the TRITS and is not standalone.
3.6.b Operating System X X The TRITS Operating System will be inspected to ensure it is either Windows 11 or a DISA compliant OS.
3.7 Power Supply
3.7.a Source X X X X The power supply will be inspected to ensure it is a 5 to 36 VDC Source. The product specification will be analyzed to ensure it is a 5 to 36 VDC Source.
3.7.b Amps X X X X The power supply will be inspected to ensure it is max 15 Amps. The product specification will be analyzed to ensure it is Max 15 Amps.
3.7.c Programmable X X X X It will be demonstrated that the power supply is controllable/ programmable via the TRITS GUI. The product specification will be analyzed to ensure the power supply is programmable and controllable.
3.8 Graphical User Interface
3.8.a Stimulus and Measurement X X It will be demonstrated that multiple stimulus and measurement functions can be accessed at the same time within the GUI.
3.8.b Multiple Instruments X X It will be demonstrated that multiple TRITS instruments can be accessed at the same time within the GUI.
REQUIREMENT/VERIFICATION CROSS REFERENCE MATRIX
METHOD OF VERIFICATION CLASSES OF VERIFICATION
N/A - NOT APPLICABLE 1 - Field User Evaluation / Bid Sample Test A - ANALYSIS 2 - Source Selection D - DEMONSTRATION C - Completed
E - EXAMINATION
T - TEST
Sec. 3 Requirements Title Method of Verification Verification Class
Verification Strategy N/A A D E T 1 C 2 C
3.9 Runtime
3.9.a Runtime Environment X X Analyze the proposal to ensure there is no subscription-fee associated to the vendor runtime software.
3.9.b API X X The proposal will be analyzed to ensure that the vendor has submitted sufficient data for their API to communicate with the TRITS internal instrumentation.
3.9.c User-Friendly X X
The FUE will consist of 9 Marine SMEs utilizing the TRITS with the submitted TPS. The users will evaluate the systems and provide feedback via surveys. The surveys will be analyzed to ensure that the user base finds the runtime easy to use and sufficient for an automated testing capability.
3.10 MTBF
3.10.a X X The proposal will be analyzed to ensure the vendor has submitted sufficient data to satisfy the MTBF requirement of 1,500 hours.
3.11 Maintenance
3.11.a Log and Fault Data X X
The proposal will be analyzed to ensure the vendor includes the ability to create log files which includes timestamp, system serial number, UUT serial number, test step, test step result, and fault information data.
3.12 Built-In Test
3.12.a BIT X X Built-In Test (BIT) will be conducted utilizing the provided built in test hardware. It will be ensured that all TRITS instrumentation is included in the BIT.
3.12.b BIT Accessories X X The TRITS BIT accessories will be inspected and it will be ensured that they all fit inside the single TRITS transit case.
3.13 Network Connectivity
REQUIREMENT/VERIFICATION CROSS REFERENCE MATRIX
METHOD OF VERIFICATION CLASSES OF VERIFICATION
N/A - NOT APPLICABLE 1 - Field User Evaluation / Bid Sample Test A - ANALYSIS 2 - Source Selection D - DEMONSTRATION C - Completed
E - EXAMINATION
T - TEST
Sec. 3 Requirements Title Method of Verification Verification Class
Verification Strategy N/A A D E T 1 C 2 C
3.13.a Ethernet/Wireless X X The TRITS will be inspected to ensure there is either an ethernet port or wireless capability that can be enabled to connect to a network.
3.14 Modularity
3.14.a Industry Standards X X The TRITS product specification and proposal will be analyzed to ensure that at least 30% of all test instrumentation is open systems architecture utilizing industry standards.
3.15 Duplex
3.15.a Transmit and Receive X X
The duplex capability will be demonstrated by utilizing an external RF Generator and Spectrum Analyzer. The TRITS RF Generator will be utilized to produce a waveform to be transmitted to an external spectrum analyzer. An external RF generator will be utilized to transmit a waveform to the TRITS receiver to be visualized in the TRITS Spectrum Analyzer. It will be ensured that both of these can be done at the same time.
For acquisition purposes, the packaging requirements shall be specified in the Statement of Work. When actual packaging of material is to be performed by Department of Defense (DoD) personnel, these personnel need to contact the responsible packaging activity to ascertain requisite packaging requirements. Packaging requirements are maintained by the Inventory
DoD Agency, or within the Military
CD-ROM products, or by contacting the responsible packaging activity.