Attachment 08 - Fire Protection Drawings.pdf

PDF 7 MB Posted

Attached to
36C77623R0039 - Y1DZ - New Mental Health Building Phase 2 Minor Construction - Providence, RI
Solicitation number
36C77623R0039
Issued by

About this file

This is a solicitation for a firm-fixed-price construction contract to design and build a new mental health building phase 2 project at the Providence VA Medical Center in Providence, Rhode Island. The selected contractor will furnish all labor, materials, equipment, tools and supervision to complete general construction, alterations, civil site work, finishes, HVAC, electrical, plumbing, fire alarm and suppression, security and other work contained in the construction documents. The scope of work includes a 3-floor expansion adjacent to an existing mental health facility building. The Department of Veterans Affairs intends to award a single contract through its Veterans Health Administration Program Contracting Activity Central office.

View the file

Other files

File Type Posted
36C77623R0039 0002.pdf PDF
Attachment 18 - Addendum 01.pdf PDF
Attachment 24 - Sheet P-001.pdf PDF
Attachment 23 - MDP Panel Info.pdf PDF
Attachment 20 - Updated Wage Rates.pdf PDF
Attachment 21 - CR211 Panel Info.pdf PDF
Attachment 19 - Technical Questions and Answers.xlsx XLSX spreadsheet
Attachment 22 - Fire Alarm As-Builts.pdf PDF
S02 - Solicitation - 36C77623R0039_R1.pdf PDF
Attachment 17 - Site Visit Sign in Sheet.pdf PDF
36C77623R0039 0001.pdf PDF
Attachment 03 - Architectural Drawings - Pt 1.pdf PDF
Attachment 12 - Limitations on Subcontracting - Construction.docx DOCX document
Attachment 04 - Architectural Drawings - Pt 2.pdf PDF
Attachment 02 - Specifications - Pt 2.pdf PDF
Attachment 15 - Providence County - Wage Rates.pdf PDF
Attachment 11 - Structural Drawings.pdf PDF
Attachment 14 - VHA Supplemental Contract Requirements for Combatting COVID-19 Updated 12-14-2021.docx DOCX document
Attachment 16 - SOW - Mental Health Phase 2.pdf PDF
Attachment 05 - Civil Drawings.pdf PDF
S02 - Solicitation - 36C77623R0039.pdf PDF
Attachment 01 - Specifications - Pt 1.pdf PDF
Attachment 07 - Electrical Drawings - Pt 2.pdf PDF
Attachment 10 - Plumbing Drawings.pdf PDF
Attachment 13 - Contractor Safety - Environmental Form.docx DOCX document
Attachment 06 - Electrical Drawings - Pt 1.pdf PDF
Attachment 09 - Mechanical Drawings.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRE PROTECTION LEGEND

SYMBOL DESCRIPTION SYMBOL DESCRIPTION

FIRE SPRINKLER BRANCH PIPING

SYMBOL DESCRIPTION

FIRE PROTECTION COMPLIANCE NOTES

FIRE PROTECTION ABBREVIATIONS

AHJ AUTHORITY HAVING JURISDICTION

(E) EXISTING

DN DOWN

DWG DRAWING

ºF DEGREES FAHRENHEIT

FDC FIRE DEPARTMENT CONNECTION

FDV FIRE DEPARTMENT VALVE

FHC FIRE HOSE CABINET

FM FACTORY MUTUAL

FP FIRE PROTECTION

FT FEET

GPM GALLONS PER MINUTE

MAX MAXIMUM

MIN MINIMUM

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NTS NOT TO SCALE

PSI POUNDS PER SQUARE INCH

RCP REFLECTED CEILING PLAN

SF SQUARE FEET

TEMP TEMPERATURE

UL UNDERWRITER'S LABORATORY

VAMC VETERANS AFFAIRS MEDICAL CENTER

FIRE PROTECTION GENERAL NOTES

BUILDING DESIGN:

THE PROVIDENCE VAMC MENTAL HEALTH PHASE 2 PROJECT IS A 3 FLOOR EXPANSION

ADJACENT TO AND CONNECTING TO THE EXISTING PROVIDENCE VAMC MENTAL

HEALTH FACILITY. THE OCCUPANCY TYPE IS CLASSIFIED AS "NEW BUSINESS".

SCOPE OF WORK:

PROVIDE A FULLY AUTOMATIC WET SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA

13 2019 EDITION. THE FIRE PROTECTION SYSTEM SHALL BE AN EXTENSION OF THE

EXISTING PHASE 1 SYSTEM. THE CURRENT SYSTEM IS CAPPED IN THE HALLWAY

OUTSIDE OF THE NEW EXPANSION ON EACH OF THE 3 FLOORS IN PREPARATION FOR

THIS PROJECT. THE CAP SHALL BE DEMOLISHED, AND A NEW CONNECTION SHALL BE

MADE TO EXTEND THE EXISTING SYSTEM TO THE NEW PHASE 2 EXPANSION. ALL

SPRINKLER HEADS SHALL BE QUICK RESPONSIVE TYPE AND INSTALLED IN CENTER OF

CEILING TILES. SPRINKLER CONTRACTOR SHALL USE EXTRAPOLATED FLOW DATA

WHEN PERFORMING HYDRAULIC CALCULATIONS.

FIRE PROTECTION SPRINKLER CONTRACTOR SHALL COORDINATE THE DESIGN AND

INSTALLATION OF THE FIRE PROTECTION SPRINKLER SYSTEM AND DELIVER A

COMPLETE, FULLY FUNCTIONAL, AND TESTED FIRE PROTECTION SYSTEM THAT

MEETS THE REQUIREMENTS OF THE FIRE PROTECTION DRAWINGS, FIRE PROTECTION

SPECIFICATIONS, LISTED CODES AND STANDARDS, AND THE REQUIREMENTS OF THE

AHJ. THE FIRE PROTECTION SPRINKLER CONTRACTOR SHALL PROVIDE AND INSTALL

NEW MATERIALS THAT ARE UL LISTED AND\OR FM APPROVED AS REQUIRED BY THE

FIRE PROTECTION DRAWINGS AND THE FIRE PROTECTION SPECIFICATIONS. THE FIRE

PROTECTION SPRINKLER CONTRACTOR SHALL INTEGRATE THE NEW FIRE SPRINKLER

SYSTEM WITH THE EXISTING PHASE 1 FIRE ALARM SYSTEM.

CHARACTERISTICS OF THE WATER SUPPLY TO BE USED:

EACH FLOOR WILL CONNECT TO THE EXISTING FIRE SPRINKLER MAIN LOCATED IN THE

EXISTING BUILDING. A CURRENT HYDRANT FLOW TEST SHALL BE PERFORMED AND

VERIFIED PRIOR TO PRODUCTION OF LAYOUT DOCUMENTS. THE CONTRACTOR SHALL

OBTAIN THE LATEST FLOW TEST DATA. FLOW TEST SHALL BE WITH THE LAST 12

MONTHS.

FLOW TEST DATA:

FLOW TEST INFORMATION UTILIZED FOR PHASE 1: 70 PSI STATIC; 66 PSI RESIDUAL;

2122 GPM FLOWING; FLOW TEST RESULTS WAS PERFORM ON FIRE HYDRANT P0135

AT VALLEY STREET AND WOLCOTT STREET ON 10/23/2018.

FLOW TEST DATA SHALL BE RE-TESTED WITHIN 12 MONTHS OF SUBMITTED WORKING

DOCUMENTS AND PROVIDED TO FIRE PROTECTION SPRINKLER CONTRACTOR FOR

USE IN HYDRAULIC CALCULATIONS FOR THE PHASE 2 EXPANSION.

QUALITY AND PERFORMANCE SPECIFICATIONS OF ALL INTERIOR FIRE PROTECTION

COMPONENTS:

ALL NEW INTERIOR FIRE PROTECTION EQUIPMENT EQUIPMENT SHALL BE UL LISTED

AND/OR FM APPROVED.

ACCEPTANCE TEST CRITERIA:

FIRE SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13, 2019 EDITION AND SHALL

COMPLY WITH THE AHJ. THE ACCEPTANCE TESTING OF

THE FIRE SPRINKLER SYSTEM AND IT'S COMPONENTS SHALL CONSIST OF ALL

APPLICABLE ITEMS SHOWN IN THE CONTRACTOR'S MATERIAL AND TEST CERTIFICATE

FOR ABOVE GROUND PIPING FORMS, NFPA 13, 2019 EDITION, CHAPTER 28 (FIG. 28.1).

SEE NFPA 13, 2019 EDITION CHAPTER 28 FOR SYSTEM ACCEPTANCE AND NFPA 25,

2020 INSPECTION TESTING AND MAINTENANCE.

A. CHAPTER 28, SYSTEM ACCEPTANCE

B. 28.1 APPROVAL OF SPRINKLER SYSTEM

C. 28.2 ACCEPTANCE REQUIREMENTS

D. 28.3 AUTOMATED INSPECTION AND TESTING DEVICES AND EQUIPMENT

E. 28.4 INSTRUCTION

F. 28.5 HYDRAULIC DESIGN INFORMATION SIGNS

APPLICABLE NFPA STANDARDS TO BE APPLIED:

A. U.S. DEPARTMENT OF VETERAN AFFAIRS FIRE PROTECTION DESIGN MANUAL -

EIGHTH EDITION

B. INTERNATIONAL BUILDING CODE 2021 EDITION

C. NFPA 13, 2019 EDITION, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS

D. NFPA 24, 2019 EDITION, STANDARD FOR THE INSTALLATION OF FIRE SERVICE MAINS

E. NFPA 25, 2020 EDITION, INSPECTION, TESTING AND MAINTENANCE OF WATER BASED

FIRE PROTECTION SYSTEM.

F. NFPA 101, 2021 EDITION, LIFE SAFETY CODE

CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR AREA:

LIGHT HAZARD:

SPACES WITH LOW QUANTITY AND COMBUSTIBILITY OF CONTENTS

I.E. OFFICES, EXAM ROOMS, CORRIDORS, MEETING ROOMS, BREAK ROOMS,

AND RESTROOMS.

ORDINARY HAZARD GROUP 1:

SPACES WITH MODERATE QUANTITY AND LOW COMBUSTIBILITY OF CONTENTS

I.E. MECHANICAL ROOMS, ELECTRICAL ROOMS, AND JANITOR CLOSETS.

DESIGN APPROACH:

SPRINKLER SYSTEM TO EXTEND INTO ALL AREAS IN ACCORDANCE WITH NFPA 13

LIGHT HAZARD OR AS NOTED. LISTED AND APPROVED SIDEWALL (5.60 K-FACTOR)

AND PENDENT (5.60 K-FACTOR) SPRINKLER HEADS TO BE PROVIDED. UPRIGHT (5.60

K-FACTOR) HEADS TO BE PROVIDED WHERE NOTED ON DRAWINGS.

LIGHT HAZARD:

SYSTEM TYPE: WET PIPE AUTOMATIC SPRINKLER SYSTEM, USING STEEL SUPPLY

PIPING TO NEW QUICK RESPONSE, PENDENT OR UPRIGHT HEADS.

K-FACTOR: 5.6 (EXTENDED COVERAGE SPRINKLER HEADS ARE ACCEPTABLE).

DENSITY: 0.10 GPM/SQ.FT.

AREA OF OPERATION: 900 SQ FT MIN AND 1500 SQ FT MAX (DESIGN AREA

REDUCTION MAY ONLY BE USED IF CEILING HEIGHT AND AREA CLASSIFICATION

PERMITS PER NFPA 13 2019 EDITION.

HEAD TEMPERATURE RATING: 155 DEGREES F.

SPACING: 225 SQ. FT. MAX. PER SPRINKLER HEAD OR BY MANUFACTURER

LITERATURE.

HOSE ALLOWANCE: 100 GPM

ORDINARY HAZARD GROUP 1:

SYSTEM TYPE: WET PIPE AUTOMATIC SPRINKLER SYSTEM, USING STEEL SUPPLY

PIPING TO NEW QUICK RESPONSE, PENDENT OR UPRIGHT HEADS.

K-FACTOR: 5.6, 8.0, 11.2, OR 14.0 (EXTENDED COVERAGE SPRINKLER HEADS ARE

ACCEPTABLE).

DENSITY: 0.15 GPM/SQ.FT.

AREA OF OPERATION: 900 SQ FT MIN AND 1500 SQ FT MAX (DESIGN AREA

REDUCTION MAY ONLY BE USED IF CEILING HEIGHT AND AREA CLASSIFICATION

PERMITS PER NFPA 13 2019 EDITION.

HEAD TEMPERATURE RATING: 155 DEGREES F.

SPACING: 130 SQ. FT. MAX. PER SPRINKLER HEAD OR BY MANUFACTURER

LITERATURE.

HOSE ALLOWANCE: 250 GPM

1. FIRE PROTECTION SYSTEM SHALL COMPLY WITH NFPA 13 (2019 EDITION) FOR

INSTALLATION OF SPRINKLER SYSTEMS. INSPECTION, TESTING, AND MAINTENANCE SHALL

COMPLY TO NFPA 25 (2020 EDITION). IN ADDITION, INSTALLATION AND INSPECTION,

TESTING, AND MAINTENANCE SHALL COMPLY WITH THE PROJECT SPECIFICATIONS AND

AHJ REQUIREMENTS.

2. FINAL INSPECTION AND APPROVAL BY AHJ.

3. SPRINKLER SHOP DRAWINGS AND MATERIAL SUBMITTALS SHALL BE SUBMITTED TO THE

ARCHITECT/ENGINEER AND AHJ AND SHALL BE APPROVED PRIOR TO ANY INSTALLATION.

THE ENGINEER OF RECORD SHALL HAVE THE RIGHT TO REJECT ANY SUBMITTALS.

4. CUTTING OF STRUCTURAL AND/OR ARCHITECTURAL MEMBERS TO BE DONE ONLY WITH

THE WRITTEN APPROVAL OF THE ARCHITECT AND STRUCTURAL ENGINEER.

5. FITTINGS REQUIRED FOR PROPER INSTALLATION, COORDINATION WITH OTHER EXISTING

TRADES, AND/OR TO MAINTAIN PROPER CLEARANCES SHALL BE PROVIDED. VERIFY

STRUCTURAL, MECHANICAL, ELECTRICAL INSTALLATIONS AND AVOID AN/ALL

OBSTRUCTIONS OR INTERFERENCES WITH FIRE PROTECTION PIPE ROUTING.

6. FIRE STOP ALL PENETRATIONS OF SMOKE/FIRE WALLS, CEILINGS, FLOORS, ROOFS, ETC., FLASH AND COUNTERFLASH ROOF PENETRATIONS.

7. PROVIDE ACCESS PANELS TO ALL VALVES ABOVE NON-ACCESSIBLE CEILINGS AND

CHASES.

8. SPRINKLER HEADS ARE TO BE COORDINATED WITH ALL LOCATIONS OF DIFFUSERS,

SPEAKERS, LIGHTING FIXTURES, CEILING SYSTEMS AND STRUCTURAL SYSTEM.

9. INDICATE CENTER TO CENTER DIMENSIONS AND/OR PIPE CUT LENGTHS AND NOMINAL

PIPE DIAMETERS ON ALL PIPING. INDICATE PIPE TYPE, SCHEDULE OF WALL THICKNESS

AND METHOD OF JOINING ON SHOP DRAWING.

10. PROVIDE STOCK OF EXTRA SPRINKLERS IN ACCORDANCE WITH NFPA 13.

11. PROVIDE DETAIL AND INDICATE TYPE OF HANGERS TO BE INSTALLED FOR SPRINKLER

PIPING. METHODS OF HANGING PIPES, HEADERS AND BRANCHES SHALL BE IN

ACCORDANCE WITH NFPA 13. ALL HANGERS ON 4" PIPE AND LARGER SHALL BE CLEVIS-

TYPE HANGERS. HANGERS SHALL NOT INTERFERE WITH ANY OTHER TRADE. POWDER

DRIVEN STUDS SHALL NOT BE USED.

12. ALL GROOVED & SCREWED FITTINGS SHALL BE UL/FM APPROVED AND SUBMITTED TO THE

ENGINEER OF RECORD FOR APPROVAL PRIOR TO ANY INSTALLATION. THE ENGINEER OF

RECORD RESERVES THE RIGHT TO DISAPPROVE ANY FITTING.

13. WELD-O-LETS SHALL BE TWO SIZES SMALLER THAN CROSS MAIN, NO LENGTH OF CROSS

MAIN SHALL BE GREATER THAN 10'-0". ALL SPRINKLER PIPING & FITTINGS SHALL BE

INSTALLED ABSOLUTELY RUST-FREE.

14. SPRINKLERS SHALL BE FM APPROVED.

15. AUTOMATIC SPRINKLER TEMPERATURE RATINGS OF FUSIBLE ELEMENTS TO BE IN

ACCORDANCE WITH NFPA 13.

16. ALL VALVES FOR FIRE SERVICE SHALL BE LISTED BY THE UNDERWRITER'S LABORATORIES, INC. AND THE FACTORY MUTUAL LABORATORIES. VALVES SHALL BE FACTORY MARKED

"UL" OR "FM", AND RATED FOR 175 WORKING PRESSURE.

17. ELECTRICALLY SUPERVISED VALVES SHALL BE PROVIDED WHERE REQUIRED IN NFPA 13.

TYPE AND EXACT LOCATION AND PURCHASE/INSTALLATION OF FLOW AND SUPERVISORY

SWITCHES SHALL BE BY THE SPRINKLER CONTRACTOR. ELECTRICAL CONTRACTOR TO

PROVIDE ADDITIONAL CIRCUITS, WIRING, SWITCHES, CONDUIT OR JUNCTION BOXES

REQUIRED.

18. SPRINKLER COVERAGE SHALL COMPLY WITH NFPA 13. SPRINKLER LOCATIONS WITH

RESPECT TO OBSTRUCTIONS SHALL COMPLY WITH NFPA 13-2019, CHAPTER 10, OR THE

APPROPRIATE CHAPTER BASED ON SPRINKLER TYPE.

19. IMMEDIATELY NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES FOUND

BETWEEN THESE PLANS, OTHER ENGINEERING PLANS, THE ARCHITECTURAL PLANS

AND/OR FIELD CONDITIONS PRIOR TO FINAL BID PRICE OR FINAL PERMITTING.

20. IN CASE OF DISPUTE OR DOUBT AS TO INTENT OF DRAWINGS OR SPECIFICATIONS, OBTAIN

ARCHITECT/ENGINEER'S WRITTEN DECISION BEFORE PROCEEDING WITH BID OR WORK

INVOLVED.

21. BEFORE SUBMITTING PROPOSAL OR BID, EXAMINE ALL DRAWINGS AND SPECIFICATIONS

RELATING TO THIS PROJECT, THE AMOUNT OF SPACE AVAILABLE FOR PIPING, EQUIPMENT

AND CONNECTING SERVICES, THE SCOPE OF SITE OF THE WORK, THE REQUIREMENTS TO

CORRELATE THE FIRE PROTECTION WORK WITH THAT OF OTHER TRADES AND THE TIME

SCHEDULE NECESSARY TO PERFORM THAT WORK.

22. PIPE SHALL BE REAMED AND CLEANED BEFORE ASSEMBLY, AND AFTER ASSEMBLY

THE ENTIRE PIPING SYSTEM SHALL BE FLUSHED CLEAN.

23. PROVIDE SPRINKLERS ABOVE AND BELOW EXPOSED DUCTWORK 4 FEET OR WIDER.

24. PROVIDE HAZARD COVERAGE FOR THE FUNCTIONS FOR EACH AREA.

25. INDICATE THE LOCATION AND SIZE OF BLIND SPACES AND CLOSETS.

26. INDICATE THE TOTAL SQUARE FOOT AREA PROTECTED BY SYSTEM(S).

27. INDICATE THE NUMBER OF SPRINKLERS ON EACH RISER.

28. ALL PENDENT SPRINKLERS SHALL BE CENTER OF TILE, UNLESS MAXIMUM

DISTANCES FROM WALLS OR BETWEEN HEADS IS EXCEEDED OR UNLESS SHOWN

DIFFERENTLY ON DRAWINGS. IF NOT POSSIBLE ALL SPRINKLER HEADS MOUNTED IN

CEILING SHALL BE LOCATED A MINIMUM OF 4" AWAY FROM ANY WALLS, CEILING

GRID MEMBERS, CEILING HEIGHT CHANGES OR ANY OTHER VERTICAL

INTERSECTING STRUCTURAL SURFACE.

29. FIRE PROTECTION CONTRACTOR SHALL ASSIST IN PREPARATION OF COORDINATION

DRAWINGS FOR ALL LEVELS WHICH INDICATE ALL THE ENGINEERING DISCIPLINES &

FIRE PROTECTION PIPING. THESE DRAWINGS SHALL BE PREPARED & APPROVED BY

THE ENGINEER OF RECORD PRIOR TO ANY INSTALLATION.

30. FIRE SPRINKLER PIPING SHALL NOT TRAVEL OVER THE TOPS OF ELECTRICAL

PANELBOARDS, IT EQUIPMENT, OR ANY ELECTRICAL EQUIPMENT.

31. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHTS IN EACH AREA.

32. ALL PIPING SHALL BE SHALL BE PAINTED PER SPECIFICATION 21 13 13.

33. ALL MATERIALS, WHERE APPLICABLE, SHALL BE U.L. LISTED OR FACTORY MUTUAL

APPROVED FOR USE IN AUTOMATIC SPRINKLER SYSTEMS. ALL NEW PIPING SHALL

BE HYDROSTATICALLY TESTED FOR TWO HOURS IN ACCORDANCE WITH NFPA 13.

MINIMUM HYDROSTATIC TEST PRESSURE SHALL BE 200 PSI.

34. FLEXIBLE SPRINKLER CONNECTIONS SHALL ONLY BE PERMITTED UPON VA

APPROVAL. IF FLEXIBLE SPRINKLER CONNECTIONS ARE PERMITTED AND USED,

HYDRAULIC CALCULATIONS MUST BE PERFORMED AND SUBMITTED TO THE

ENGINEER OF RECORD.

35. THE SMALL ROOM RULE SHALL BE ACCEPTABLE FOR PLACEMENT OF SPRINKLERS

PER NFPA 13-2019, 10.2.5.2.1.

36. UPON SPRINKLER SYSTEM IMPAIRMENT, NFPA 25-2020, 15.5.2 SHALL BE FOLLOWED

DURING SPRINKLER SYSTEM DOWNTIME. APPROVED PERSONNEL SHALL

COORDINATE REQUIREMENTS PER NFPA 25, SUCH AS AN APPROVED FIRE WATCH IF

REQUIRED. IMPAIRMENT PROCEDURES REQUIRED TO BE TAKEN SHALL BE

INCLUDED IN CONTRACTOR'S BUDGET.

FB

-CONNECT TO EXISTING

-DEMOLISH TO POINT INDICATED

VIEW NUMBER

DRAWING NUMBER WHERE SHOWN

SECTIONLETTER

FP4

FP7

A

SHEET NUMBER

REVISION REFERENCEXX

SHEET NOTE CALLOUTXX

DRAWING SYMBOLS

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

ENGINEER ARCHITECT/ENGINEER OF RECORD

WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn www.abovegroupinc.com

COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

/2

/2

:3

:3

A

M B

IM

/0

V A

P ro v id e n c e M e n ta l H e a lt h

B u ild in g

P H

/0

V A

P ro v id e n c e

M H

C P

H

R

D iv

.r v t

FP001

650-347

PROVIDENCE VAMC MENTAL

HEALTH PHASE 2

PROVIDENCE, RI

ADL AJZFEB 04 2022

CONSTRUCTION

DOCUMENTS

FIRE PROTECTION LEGENDS,

SYMBOLS, & NOTES

FULLY SPRINKLERED

Allen D. Lantz, P.E.

MD License #41513

FIRE PROTECTION DRAWING INDEX

Sheet Number Sheet Name

FP001 FIRE PROTECTION LEGENDS, SYMBOLS, & NOTES

FP100 FIRE PROTECTION AREAS OF WORK

FP111 LEVEL B PLAN - FIRE PROTECTION

FP121 LEVEL 1 PLAN - FIRE PROTECTION

FP131 LEVEL 2 PLAN - FIRE PROTECTION

FP501 FIRE PROTECTION DETAILS

Revisions: Revision Description Date:

2-A

2-C

2-F

2-8 2-7

2-6

2-5

2-4 2-3 2-2.12-22-1

2-B

2-D

2-E

E.5

E.9

AREA OF WORK

2-A

2-C

2-F

2-8 2-7

2-6

2-5

2-4 2-3 2-2.12-22-1

2-B

2-D

2-E

E.5

E.9

AREA OF WORK

2-A

2-C

2-F

2-8 2-7

2-6

2-5

2-4 2-3 2-2.1

2-22-1

2-B

2-D

2-E

E.5

E.9

AREA OF WORK

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

ENGINEER ARCHITECT/ENGINEER OF RECORD

WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH

PROJECT NORTH

www.abovegroupinc.com

COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

/2

/2

:3

:3

A

M B

IM

/0

V A

P ro v id e n c e M e n ta l H e a lt h

B u ild in g

P H

/0

V A

P ro v id e n c e

M H

C P

H

R

D iv

.r v t

FP100

650-347

PROVIDENCE VAMC MENTAL

HEALTH PHASE 2

PROVIDENCE, RI

ADL AJZFEB 04 2022

CONSTRUCTION

DOCUMENTS

FIRE PROTECTION AREAS OF

WORK

FULLY SPRINKLERED

Allen D. Lantz, P.E.

MD License #41513

1/16" = 1'-0"C3

LEVEL B AREA OF WORK - FIRE PROTECTION

1/16" = 1'-0"F1

LEVEL 1 AREA OF WORK - FIRE PROTECTION

1/16" = 1'-0"F5

LEVEL 2 AREA OF WORK - FIRE PROTECTION

CODED NOTES:

EXISTING FIRE RISER LOCATED IN ROOM 020 IN PHASE 1.

REFER TO SHEET FP111 FOR LEVEL B FIRE PROTECTION.

REFER TO SHEET FP121 FOR LEVEL 1 FIRE PROTECTION.

REFER TO SHEET FP131 FOR LEVEL 2 FIRE PROTECTION.

2-A

2-C

2-F

2-8

2-7

2-6

2-5

2-4

2-3 2-2.1 2-2 2-1

2-B

2-D

2-E

E.5

E.9

3" FB

CONTINUED TO (E)FLOOR

CONTROL VALVE LOCATED IN

PHASE 1 FIRE ENTRANCE

ROOM

STAIR 1

STAFF TOILET

TEAM RM

OFFICE (TRIPLE)

OFFICE (TRIPLE)

CONSULT ROOM

CONSULT ROOM

STORAGE

CONSULT ROOM

PUBLIC TOILET

MSA

WAITING AREA

CORRIDOR

CHIEF OFFICE

OFFICE

OFFICE

CONSULT ROOM

OFFICE (DOUBLE)

OFFICE (DOUBLE)

OFFICE (TRIPLE)

OFFICE (TRIPLE)

ELEC. CL.

STAIR 3

HAC

VETERAN W.S.

CORRIDOR

034A

PRINTER

034B

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

ENGINEER ARCHITECT/ENGINEER OF RECORD

WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH

PROJECT NORTH

www.abovegroupinc.com

COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

/2

/2

:3

:3

A

M B

IM

/0

V A

P ro v id e n c e M e n ta l H e a lt h

B u ild in g

P H

/0

V A

P ro v id e n c e

M H

C P

H

R

D iv

.r v t

FP111

650-347

PROVIDENCE VAMC MENTAL

HEALTH PHASE 2

PROVIDENCE, RI

ADL AJZFEB 04 2022

CONSTRUCTION

DOCUMENTS

LEVEL B PLAN - FIRE PROTECTION

FULLY SPRINKLERED

Allen D. Lantz, P.E.

MD License #41513

0 4' 8' 16' 24'

1/8" = 1'-0"

1/4" = 1'-0" F1

LEVEL B PLAN - FIRE PROTECTION

0 4' 8' 16' 24'

1/8" = 1'-0"

CODED NOTES:

PROVIDE A HYDRAULICALLY CALCULATED AUTOMATIC SPRINKLER SYSTEM FOR A LIGHT HAZARD

OCCUPANCY WITH A MINIMUM DENSITY/AREA OF 0.10 GPM/SF OVER 1500 SF PER NFPA 13.

LEGEND:

PROVIDE A HYDRAULICALLY CALCULATED AUTOMATIC SPRINKLER SYSTEM FOR A ORDINARY HAZARD GROUP 1 OCCUPANCY WITH A MINIMUM DENSITY/AREA OF 0.15 GPM/SF OVER 1500 SF PER NFPA 13.

LEGEND:

REMOVE AND DISPOSE OF (E)CAP. EXTEND 3" FIRE PROTECTION MAIN FROM PHASE 1 BUILDING.

PROVIDE FLEXIBLE COUPLING AT STRUCTURAL EXPANSION JOINT PER 2019 NFPA 13-18.2.3.1(4).

DRAWING NOTES:

1. COORDINATE SPRINKLER HEIGHT WITH ARCHITECTURAL RCP. REFER TO ARCHITECTURAL PLANS.

2. REFER TO FIRE PROTECTION GENERAL NOTE #36 / FP001 FOR SPRINKLER SYSTEM IMPAIRMENT

REQUIREMENTS.

P1P2

KEY PLAN

2-A

2-C

2-F

2-8

2-7

2-6

2-5

2-4

2-3 2-2.1 2-2 2-1

2-B

2-D

2-E

E.5

E.9

3" FB

CONTINUED TO (E)FLOOR

CONTROL VALVE LOCATED IN

PHASE 1 COMMUNICATION

CENTER 103

STAIR 1

STAIR 3

LOUNGE, STAFF

STAFF TOILET

OFFICE

139 TELEDATA

138 COUPLE'S

THERAPY

137 COUPLE'S

THERAPY

COUPLE'S

THERAPY

GROUP THERAPY

134 PUBLIC TOILET

MSA

WAITING AREA

GROUP THERAPY

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

ELEC. CL.

SECTION CHIEF

143 CORRIDOR

PRINTER

131A

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

ENGINEER ARCHITECT/ENGINEER OF RECORD

WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH

PROJECT NORTH

www.abovegroupinc.com

COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

/2

/2

:3

:3

A

M B

IM

/0

V A

P ro v id e n c e M e n ta l H e a lt h

B u ild in g

P H

/0

V A

P ro v id e n c e

M H

C P

H

R

D iv

.r v t

FP121

650-347

PROVIDENCE VAMC MENTAL

HEALTH PHASE 2

PROVIDENCE, RI

ADL AJZFEB 04 2022

CONSTRUCTION

DOCUMENTS

LEVEL 1 PLAN - FIRE PROTECTION

FULLY SPRINKLERED

Allen D. Lantz, P.E.

MD License #41513

1/4" = 1'-0" F1

LEVEL 1 PLAN - FIRE PROTECTION

0 4' 8' 16' 24'

1/8" = 1'-0"

0 4' 8' 16' 24'

1/8" = 1'-0"

CODED NOTES:

PROVIDE A HYDRAULICALLY CALCULATED AUTOMATIC SPRINKLER SYSTEM FOR A LIGHT HAZARD

OCCUPANCY WITH A MINIMUM DENSITY/AREA OF 0.10 GPM/SF OVER 1500 SF PER NFPA 13.

LEGEND:

PROVIDE A HYDRAULICALLY CALCULATED AUTOMATIC SPRINKLER SYSTEM FOR A ORDINARY HAZARD GROUP 1 OCCUPANCY WITH A MINIMUM DENSITY/AREA OF 0.15 GPM/SF OVER 1500 SF PER NFPA 13.

LEGEND:

REMOVE AND DISPOSE OF (E)CAP. EXTEND 3" FIRE PROTECTION MAIN FROM PHASE 1 BUILDING.

PROVIDE FLEXIBLE COUPLING AT STRUCTURAL EXPANSION JOINT PER 2019 NFPA 13-18.2.3.1(4).

DRAWING NOTES:

1. COORDINATE SPRINKLER HEIGHT WITH ARCHITECTURAL RCP. REFER TO ARCHITECTURAL PLANS.

2. REFER TO FIRE PROTECTION GENERAL NOTE #36 / FP001 FOR SPRINKLER SYSTEM IMPAIRMENT

REQUIREMENTS.

P1P2

2-A

2-C

2-F

2-8

2-7

2-6

2-5

2-4

2-3 2-2.1 2-2 2-1

2-B

2-D

2-E

E.5

E.9

CONTINUED TO (E)FLOOR

CONTROL VALVE LOCATED IN

PHASE 1 MECHANICAL ROOM

STAIR 1

STAIR 3

PUBLIC TOILET

STAFF TOILET

N.P. OFFICE

N.P. OFFICE

N.P. OFFICE

N.P. OFFICE

N.P. OFFICE

N.P. OFFICE

MECH. RM.

ELEC. RM.

CORRIDOR

OFFICE/CONSULT

OFFICE

OFFICE/CONSULT

OFFICE

OFFICE

CHIEF OFFICE

CORRIDOR

HAC

216 PRINTER

204A

WAITING AREA

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

ENGINEER ARCHITECT/ENGINEER OF RECORD

WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH

PROJECT NORTH

www.abovegroupinc.com

COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

/2

/2

:3

:4

A

M B

IM

/0

V A

P ro v id e n c e M e n ta l H e a lt h

B u ild in g

P H

/0

V A

P ro v id e n c e

M H

C P

H

R

D iv

.r v t

FP131

650-347

PROVIDENCE VAMC MENTAL

HEALTH PHASE 2

PROVIDENCE, RI

ADL AJZFEB 04 2022

CONSTRUCTION

DOCUMENTS

LEVEL 2 PLAN - FIRE PROTECTION

FULLY SPRINKLERED

Allen D. Lantz, P.E.

MD License #41513

0 4' 8' 16' 24'

1/8" = 1'-0"

1/4" = 1'-0" F1

LEVEL 2 PLAN - FIRE PROTECTION

CODED NOTES:

PROVIDE A HYDRAULICALLY CALCULATED AUTOMATIC SPRINKLER SYSTEM FOR A LIGHT HAZARD

OCCUPANCY WITH A MINIMUM DENSITY/AREA OF 0.10 GPM/SF OVER 1500 SF PER NFPA 13.

LEGEND:

PROVIDE A HYDRAULICALLY CALCULATED AUTOMATIC SPRINKLER SYSTEM FOR A ORDINARY HAZARD GROUP 1 OCCUPANCY WITH A MINIMUM DENSITY/AREA OF 0.15 GPM/SF OVER 1500 SF PER NFPA 13.

LEGEND:

REMOVE AND DISPOSE OF (E)CAP. EXTEND 3" FIRE PROTECTION MAIN FROM PHASE 1 BUILDING.

PROVIDE FLEXIBLE COUPLING AT STRUCTURAL EXPANSION JOINT PER 2019 NFPA 13-18.2.3.1(4).

DRAWING NOTES:

1. COORDINATE SPRINKLER HEIGHT WITH ARCHITECTURAL RCP. REFER TO ARCHITECTURAL PLANS.

2. REFER TO FIRE PROTECTION GENERAL NOTE #36 / FP001 FOR SPRINKLER SYSTEM IMPAIRMENT

REQUIREMENTS.

0 4' 8' 16' 24'

1/8" = 1'-0"

P1P2

CONCRETE FASTENER (U.L. LISTED

OR F.M. APPROVED)

PIPE HANGER RING (U.L. LISTED

OR F.M. APPROVED)

ALL THREAD ROD

CEILING

ESCUTCHEON

FINISH

CEILING

1" SUPPLY LINE

1"x1/2" REDUCING

COUPLING

PENDANT TYPE SPRINKLER

HEAD

CEILING

1/2"REDUCER

BRANCH LINE

1" 90° ELL1" 90° ELL

1" DROP

1. WALL ASSEMBLY--THE 1, 2, 3 OR 4 HR FIRE-RATED GYPSUM

WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE

MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR

U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE

DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION

FEATURES:

A. STUDS--WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS

(MAX 2 H FIRE RATED ASSEMBLIES OR STEEL CHANNEL STUDS.

WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16

IN. OC WITH NOM 2 BY 4 IN. LUMBER END PLATES AND CROSS

BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. WIDE BY 1-3/8 IN. DEEP

CHANNELS SPACED MAX 24 IN. OC.

B. WALLBOARD, GYPSUM *--NOM 1/2 OR 5/8 IN. THICK, 4 FT. WIDE WITH

SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE,

THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET

ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR

U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX

DIAM OF OPENING IS 13-1/2 IN.

2. PIPE OR CONDUIT--NOM 12 IN. DIAM (OR SMALLER) SCHEDULE 10 (OR

HEAVIER) STEEL PIPE, NOM 12 IN. DIAM (OR SMALLER) SERVICE WEIGHT (OR

HEAVIER) CAST IRON SOIL PIPE, NOM 12 IN. DIAM (OR SMALLER) CLASS 50

(OR HEAVIER) DUCTILE IRON PRESSURE PIPE, NOM 6 IN. DIAM (OR SMALLER)

STEEL CONDUIT, NOM 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL

METALLIC TUBING, NOM 6 IN. DIAM (OR SMALLER) TYPE L OR (OR

HEAVIER) COPPER TUBING OR NOM 1 IN. DIAM (OR SMALLER) FLEXIBLE

STEEL CONDUIT. WHEN COPPER PIPE IS USED, MAX F RATING OF FIRESTOP

SYSTEM (ITEM 3) IS 2 H. STEEL PIPES OR CONDUITS LARGER THAN NOM 4 IN.

DIAM MAY ONLY BE USED IN WALLS CONSTRUCTED USING STEEL CHANNEL

STUDS. A MAX OF ONE PIPE OR CONDUIT IS PERMITTED IN THE FIRESTOP

SYSTEM. PIPE OR CONDUIT TO BE INSTALLED NEAR CENTER OF STUD

CAVITY WIDTH AND TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL

ASSEMBLY.

3. FILL, VOID OR CAVITY MATERIAL*--CAULK--CAULK FILL MATERIAL INSTALLED

TO COMPLETELY FILL ANNULAR SPACE BETWEEN PIPE OR CONDUIT AND

GYPSUM WALLBOARD AND WITH A MIN 1/4 IN. DIAM BEAD OF CAULK APPLIED

TO PERIMETER OF PIPE OR CONDUIT AT ITS EGRESS FROM THE WALL.

CAULK INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL ASSEMBLY.

THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON

THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS

INSTALLED, AS SHOWN IN THE FOLLOWING TABLE. THE HOURLY T RATING

OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE

PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY

IN WHICH IT IS INSTALLED, AS TABULATED BELOW:

Max pipe or Conduit Diam

In.

+When copper is used, T Rating is 0h.

SECTION A-A

12 3/16 to 3/8

1/4 to 1/2

0 to 1-1/2

1/4 to 1/2

3 to 3/16

3 or 4

1 or 2

1 or 2

3 or 4

1 or 2 0

0+, 1 or 2

3 or 4

Minnesota Mining & Mfg. Co .--Types FB-2000, FB-2000+.

*Bearing the UL Classification Marking

System No. W-L-1001

(Formerly System No. 147)

F Rating--1, 2, 3 and 4 Hr (See Items 2 and 3)

T Ratings--0, 1, 2, 3, and 4 Hr (See Items 2 and 3)

L Rating at Ambient--less than 1 CFM/sq ft

L Rating At 400 F--less than 1 CFM/sq ft

Annular Space In. F Rating Hr. T Rating Hr.

A

A

1B

1A

1. FLOOR OR WALL ASSEMBLY - LIGHTWEIGHT OR NORMAL WEIGHT (100-150PCF)

CONCRETE. EXCEPT AS NOTED IN TABLE UNDER ITEM 4, MIN THICKNESS OF SOLID

CONCRETE FLOOR OR WALL ASSEMBLY IS 4-1/2". FLOOR MAY ALSO BE CONSTRUCTED

OF A MIN. 6" THICK. UL CLASSIFIED HOLLOW CORE PRECAST CONCRETE UNITS*. WHEN

FLOOR IS CONSTRUCTED OF HOLLOW CORE PRECAST CONCRETE UNITS, PACKING

MATERIAL (ITEM 3) AND CAULK FILL MATERIAL (ITEM 4) TO BE INSTALLED

SYMMETRICALLY ON BOTH SIDES OF FLOOR, FLUSH WITH FLOOR SURFACE. WALL

ASSEMBLY MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS*.

MAX. DIA. OF OPENING IS IN SOLID LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE.

FLOOR IS 32" MAX. DIA. OF OPENING IN FLOOR CONSTRUCTED OF HOLLOW-CORE

PRECAST CONCRETE UNITS IS 7".

SEE CONCRETE BLOCKS (CAZT) AND PRECAST CONCRETE UNITS (CFTV)

CATEGORIES IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS.

1A. STEEL SLEEVE - (OPTIONAL, NOT SHOWN) - MAX. 15" ID (OR SMALLER) SCHEDULE 10

(OR HEAVIER) STEEL SLEEVE CAST OR GROUTED INTO FLOOR OR WALL ASSEMBLY.

SLEEVE MAY EXTEND A MAX. OF 2" ABOVE TOP OF FLOOR OR BEYOND EITHER

SURFACE OF WALL. MAX. 16" ID (OR SMALLER) MIN. 0.028 WALL THICKNESS (OR

HEAVIER) GALVANIZED STEEL SLEEVE CAST OR GROUTED INTO FLOOR OR WALL

ASSEMBLY. SLEEVE MAY EXTEND A MAX. OF 1/2" BEYOND EITHER SURFACE OF FLOOR

OR WALL.

2. THROUGH PENETRANT'S - ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED

EITHER CONCENTRIC ALLY OR ECCENTRIC ALLY WITHIN THE FIRESTOP SYSTEM. MAX.

ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND EDGE OF THROUGH

OPENING OR SLEEVE IS DEPENDENT ON THE PARAMETERS SHOWN IN ITEM 4. MIN.

ANNULAR SPACE BETWEEN PIPE OR CONDUIT AND EDGE OF THROUGH OPENING IS 0".

(POINT CONTACT). PIPE CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH

SIDES OF FLOOR OR WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF

METALLIC PIPES, CONDUITS OR TUBING MAY BE USED

A. STEEL PIPE - NOM. 30" DIA. (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE

B. IRON PIPE - NOM. 30" DIA. (OR SMALLER) CAST OR DUCTILE IRON PIPE

C. CONDUIT - NOM. 6" DIA. (OR SMALLER) RIGID STEEL CONDUIT

D. CONDUIT - NOM. 4" DIA. (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING

E. COPPER TUBING - NOM. 8" DIA. (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBE

F. COPPER PIPE - NOM. 6" DIA. (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE

3. PACKING MATERIAL - POLYETHYLENE BACKER ROD OR NOM. 1" THICKNESS OF

TIGHTLY PACKED MINERAL WOOL BATT OR GLASS FIBER INSULATION FIRMLY PACKED

INTO OPENING AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM

TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF WALL AS REQUIRED TO

ACCOMMODATE THE REQUIRED THICKNESS OF CAULK FILL MATERIAL (ITEM 4).

4. FILL, VOID OR CAVITY MATERIAL* - CAULK - APPLIED TO FILL THE ANNULAR SPACE

FLUSH WITH TOP SURFACE OF FLOOR. IN WALL ASSEMBLIES, REQUIRED CAULK

THICKNESS TO BE INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL, FLUSH WITH

WALL SURFACE, AT POINT CONTACT LOCATION BETWEEN PENETRANT AND SLEEVE

OR BETWEEN PENETRANT AND CONCRETE, A MIN. 1/4" DIA. BEAD OF CAULK SHALL BE

APPLIED AT TOP SURFACE PIPE CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON

BOTH SIDES OF FLOOR OR WALL OF FLOOR AND AT BOTH SURFACES OF WALL.

THE HOURLY F RATINGS AND THE MIN. REQUIRED CAULK THICKNESS' ARE

DEPENDENT UPON A NUMBER OF PARAMETERS, AS SHOWN IN THE FOLLOWING

TABLE:

min. floor or wall nom. pipe tube or conduit thickness, in. dia.., in.

max. annular space, in. thickness, in.

min. caulk f rating, hr.

21/21-3/81/2-122-1/2

22-1/2 1/2-12 3-1/4 1

24-1/2 1/2-6 1-3/8 1/4 (A)

34-1/2 1/2-12 1-1/4 1/2

4-1/2 1/2-20 2 1 3

4-1/2

1/2-6

2 1

34-1/2 1/2-12 3-1/4 1

44-1/2

1/2-20

1-3/8 1 (B)

(A) min. 2" thickness of mineral wool batt insulation required in annular space.

(B) min. 1" thickness of mineral wool batt insulation required in annular space. on both sides of floor or wall assembly. min 1" thickness of caulk to be installed flush with each surface of floor or wall assembly.

minnesota mining and manufacturing co. - cp 25wb+.

*bearing the ul classification marking

SECTION A-A

System No. C-AJ-1044

(formerly system no. 319)

F Rating - 2, 3 and 4 Hr (see items 2A and 4)

T Rating - 0 Hr

L Rating At Ambient - 2 CFM/sq ft

L Rating At 400 F - less than 1 CFM/sq ft

A

4A

4 1

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

ENGINEER ARCHITECT/ENGINEER OF RECORD

WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn www.abovegroupinc.com

COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

/2

/2

:3

:4

A

M B

IM

/0

V A

P ro v id e n c e M e n ta l H e a lt h

B u ild in g

P H

/0

V A

P ro v id e n c e

M H

C P

H

R

D iv

.r v t

FP501

650-347

PROVIDENCE VAMC MENTAL

HEALTH PHASE 2

PROVIDENCE, RI

ADL AJZFEB 04 2022

CONSTRUCTION

DOCUMENTS

FIRE PROTECTION DETAILS

FULLY SPRINKLERED

Allen D. Lantz, P.E.

MD License #41513

N.T.S.

CONCRETE HANGER DETAIL

B8

N.T.S.

PENDENT SPRINKLER HEAD DETAIL

D8

N.T.S.

RETURN BEND DETAIL

F8

N.T.S.

WALL - DRYWALL - PIPE - 1/2/3/4 HR

D6N.T.S.

WALL/FLR - CONC - PIPE - 2/3/4 HR

D3

FIRE ALARM SYMBOLS

SYMBOL DESCRIPTION

ALARM, FIRE, PANEL; LETTERS INDICATE AS FOLLOWS:

FACC = CENTRAL CONSOLE FACP = CONTROL PANEL

MFACP= MASTER CONTROL PANEL FAAP = ANNUNCIATOR PANEL

ALARM, SPEAKER/LIGHT, ONE ASSEMBLY. ADJUSTABLE

15CD, 30CD, 75CD UNLESS OTHERWISE NOTED

ALARM, SPEAKER/LIGHT, ONE ASSEMBLY WITH CHIME.

ADJUSTABLE 15CD, 30CD, 75CD UNLESS OTHERWISE NOTED

ALARM, SPEAKER/LIGHT, SEPARATE ASSEMBLY. ADJUSTABLE

15CD, 30CD, 75CD UNLESS OTHERWISE NOTED

ALARM, LAMP LIGHT, SIGNAL LIGHT, STROBE. ADJUSTABLE

15CD, 30CD, 75CD UNLESS OTHERWISE NOTED

DETECTOR, HEAT

DETECTOR, SMOKE, FOR DUCT

FIRE ALARM TERMINAL CABINET.

FIRE ALARM STATION, MANUAL PULL

FACP

C

FATC

HD

FIRE ALARM ABBREVIATIONS

1PH SINGLE-PHASE

1P SINGLE POLE

2/C TWO-CONDUCTOR

3/C THREE-CONDUCTOR

3PH THREE-PHASE

4/C FOUR-CONDUCTOR

4W FOUR-WIRE

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT/ENGINEER

AAP ALARM ANNUNCIATOR PANEL

AC ALTERNATING CURRENT OR ARMORED CABLE

ACC ACCESSIBLE

ADDL ADDITIONAL

ADJ ADJACENT, ADJOINING

ADO AUTOMATIC DOOR OPENER

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AHJ AUTHORITY HAVING JURISDICTION

ALT ALTERNATE

AMB OR A AMBIENT

ARCH ARCHITECT

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AV AUDIO VISUAL

BAT BATTERY

BC BARE COPPER

BD BOARD

BFF BELOW FINISH FLOOR

BLDG BUILDING

BPIP BOILER PLANT INSTRUMENTATION PANEL

BYP BY PASS

C CONDUIT

CAB CABINET

CALC CALCULATE

CAP CAPACITY

CAT CATALOG

CATV COMMUNITY ANTENNA TELEVISION

CCR CONTROL CONTACTOR

CCTV CLOSED CIRCUIT TELEVISION

CD CONSTRUCTION DOCUMENTS

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED

CFE CONTRACTOR FURNISHED EQUIPMENT

CLG CEILING

CMU CONCRETE MASONRY UNIT

COAX COAX CABLE

COMM COMMUNICATION

COMPT COMPARTMENT

CONC CONCRETE

CONT CONTINUE

CONTR CONTRACTOR

COORD COORDINATE

CTV CABLE TELEVISION

CU COPPER

CU FT CUBIC FEET

CUR CURRENT

OC ON CENTER

OD OUTSIDE DIAMETER

P POLE

PA PUBLIC ADDRESS

PB PANELBOARD, PULL BOX, OR PUSHBUTTON

PBPU PREFABRICATED BEDSIDE PATIENT UNIT

PED PEDESTAL

PEND PENDANT

PF POWER FACTOR

PH PHASE

PNL PANEL

PVC POLYVINYL CHLORIDE (PLASTIC)

PWR POWER

RCP REFLECTED CEILING PLAN

REC RECESSED

RECPT RECEPTACLE

RGS RIGID GALVANIZED STEEL

RM ROOM

REQD REQUIRED

SF SQUARE FOOT (FEET)

SHT SHEET

SI INTERNATIONAL SYSTEM OF UNITS

SPEC SPECIFICATION

SURF SURFACE

SW SWITCH

TEL TELEPHONE

TP TWISTED PAIR

TPS TWISTED PAIR SHIELDED

TTB TELEPHONE TERMINAL BOARD

TV TELEVISION

TYP TYPICAL

UFD UNDERFLOOR DUCT

UGND UNDERGROUND

UL UNDERWRITERS LABORATORY

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER SUPPLY

UTIL UTILITY

V VOLT

WP WEATHERPROOF

DB DECIBEL OR DIRECT BURIAL

DC DIRECT CURRENT

DEG C DEGREES CELSIUS

DEG F DEGREES FAHRENHEIT

DEMO DEMOLITION

DIAG DIAGRAM

DISTR DISTRIBUTION

DN DOWN

DRSW DOOR SWITCH

DWG DRAWING

EC EMPTY CONDUIT

EG EQUIPMENT GROUND

EL ELEVATION

ELEC ELECTRIC OR ELECTRICAL

ELEV ELEVATOR

EMER EMERGENCY

EMI ELECTROMAGNETIC INTERFERENCE

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

EPO EMERGENCY POWER OFF

ESMT EASEMENT

EXIST EXISTING

FLEX FLEXIBLE METALLIC CONDUIT

FOUTT TELEPHONE FLOOR OUTLET

FP FIRE PROTECTION

FT FEET OR FOOT

FU SW FUSED SWITCH

G OR GND GROUND OR GENERATOR

GEN GENERATOR

GTB GROUND TERMINAL BOX

HOA HAND-OFF-AUTOMATIC

HT HEIGHT

HZ HERTZ

IMC INTERMEDIATE METAL CONDUIT

IR INFRARED

J-BOX JUNCTION BOX

LF LINEAR FEET (FOOT)

LTNG LIGHTING

LV LOW VOLTAGE

MATV MASTER ANTENNA TELEVISION SYSTEM

MAX MAXIMUM

MECH MECHANICAL

MH MANHOLE

MIN MINIMUM

MT MOUNT

MTD MOUNTED

MTG MOUNTING

NA NOT APPLICABLE

NEC NATIONAL ELECTRICAL CODE

NEUT OR N NEUTRAL

NIC NOT IN CONTRACT

NS NO SCALE

NTS NOT TO SCALE

CEILING ALARM, SPEAKER/LIGHT, ONE ASSEMBLY.

ADJUSTABLE 15CD, 30CD, 75CD UNLESS OTHERWISE NOTED

ABBR. DESCRIPTION ABBR. DESCRIPTION ABBR. DESCRIPTION

FA1. ALL FIRE ALARM EQUIPMENT IS TO BE NEW, UL LISTED FOR FIRE SERVICE,

AND SHALL BE COMPATIBLE WITH THE SYSTEM BEING USED. THE EXISTING

FIRE ALARM SYSTEM IS NOTIFIER NSF2-640 SYSTEM.

FA2. ALL WIRING AND CONDUIT IS TO CONFORM TO NEC ARTICLE 760. WIRING

SHALL BE UL LISTED, MINIMUM 300V TYPE FPLP PLENUM RATED SOLID

COPPER OR STANDARD COPPER WITH MAXIMUM 19 STRANDS.

FA3. LOW VOLTAGE CONDUCTORS: PROVIDE CONDUCTORS IN ACCORDANCE WITH

NFPA 70 AND NFPA 72, AND AS RECOMMENDED BY THE FIRE ALARM SYSTEM

MANUFACTURER. CONDUCTORS SHALL BE COPPER, MINIMUM NO. 14 AWG,

TWISTED SHIELDED PAIR.

FA4. SURVIVABILITY: PER AUTHORITY HAVING JURISDICTION, WIRING INSTALLED IN

METAL RACEWAY WITHIN BUILDINGS THAT ARE PROTECTED THROUGHOUT BY

SPRINKLERS SHALL BE CONSIDERED TO MEET THE REQUIREMENTS FOR

PATHWAY SURVIVABILITY LEVEL 2 IN ACCORDANCE WITH NFPA 72 (2020) AS A

2-HOUR PERFORMANCE ALTERNATIVE.

FA5. ALL FIRE ALARM POWER CIRCUITS SHALL HAVE A DEDICATED 120V 20A

BREAKER THAT SHALL BE RED IN COLOR AND MECHANICALLY PROTECTED

(LOCKABLE IN THE "ON" POSITION), MARKED AS "FIRE ALARM CIRCUIT".

FA6. MINIMUM CANDELA RATING OF STROBES IS 15; "##" ADJACENT TO DEVICE

INDICATES THE CANDELA RATING. PROVIDE SYNCHRONIZATION OF STROBES

IN ALL ADJACENT AREAS WHERE STROBES ARE VISIBLE TO EACH OTHER.

FA7. FIRE ALARM DESIGN IS IN ACCORDANCE WITH THE NATIONAL FIRE

PROTECTION ASSOCIATION (NFPA 72 - 2019) AND NATIONAL FIRE CODES (NFC).

WHERE A FIRE ALARM RISER IS INDICATED, IT IS DIAGRAMMATIC IN NATURE

AND NOT INTENDED TO REPRESENT A COMPLETE WIRING AND DEVICE

DISPLAY. ALL WIRING AND DEVICES SHALL BE IN ACCORDANCE WITH

SELECTED VENDOR'S POINT-BY-POINT WIRING DIAGRAM. REFER TO FLOOR

PLAN FOR DESIGN INTENT AND PROPOSED QUANTITY OF FIRE ALARM SYSTEM

COMPONENTS.

FA8. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED TO

SHOW ALL POSSIBLE CONDITIONS. IT IS INTENDED THAT A COMPLETE FIRE

ALARM SYSTEM BE PROVIDED WITH ALL THE NECESSARY EQUIPMENT,

WIRING, CONDUIT, AND CONTROLS, COMPLETELY COORDINATED WITH ALL

DISCIPLINES. THE MINIMUM FIRE ALARM DESIGN CRITERIA IN THESE

DOCUMENTS SHALL BE STRICTLY CONFORMED TO IN ACCORDANCE WITH

61G15-30.008. ANY ITEMS AND LABOR REQUIRED FOR A COMPLETE FIRE

ALARM SYSTEM, IN ACCORDANCE WITH ALL APPLICABLE CODES, STANDARDS,

LOCAL AUTHORITIES AND THESE CONTRACT DOCUMENTS SHALL BE

FURNISHED AT NO ADDITIONAL COST TO THE OWNER. THE FIRE ALARM

CONTRACTOR SHALL CAREFULLY REVIEW ALL CONTRACT DOCUMENTS AND

THE DESIGN OF OTHER TRADES BEFORE PREPARING SHOP DRAWINGS.

FA9. FIRE ALARM CONTRACTOR SHALL BE AWARE OF THE TYPE OF FINISHES,

DECOR AND OCCUPANCY. COORDINATION WITH THE STAKEHOLDERS(S)

SHALL BE PERFORMED BY THE FIRE ALARM CONTRACTOR FOR PLACEMENT

OF FIRE ALARM DEVICES.

FA10. FIRE ALARM SYSTEM SHALL COMPLY WITH NFPA 70 AND 72 FOR PROPER

INSTALLATION PRACTICES.

FA11. FIRE ALARM PATHWAYS IN ALL AREAS SHALL BE IN 3/4" EMT, AND SHALL BE

PAINTED RED. ALL FIRE ALARM WIRING SHALL BE ROUTED THROUGH CONDUIT

THAT IS STRICTLY DEDICATED FOR FIRE ALARM. NO OTHER SYSTEMS MAY

UTILIZE FIRE ALARM WIRING CONDUIT OR EMT.

FA12. ALL FIRE ALARM JUNCTION BOX AND PULL BOX COVERS SHALL BE PAINTED

RED.

FA13. PERFORM RE-ACCEPTANCE TESTING IN ACCORDANCE WITH NFPA 72.

FA14. FIRE ALARM CIRCUITS SHALL NOT HAVE SPLICES. CIRCUITS SHALL BE

EXTENDED FROM DEVICE AND APPLIANCE SCREW TERMINALS.

FIRE ALARM SYSTEM NOTES

P

ALL FIRE ALARM NOTIFICATION AND INITIATION DEVICES WILL BE CONNECTED TO THE

EXISTING NOTIFIER NSF2-640 FIRE ALARM SYSTEM THAT IS BEING INSTALLED UNDER A

SEPARATE PROJECT THROUGH A NEW BOOSTER PANEL (NAC).

FIRE ALARM SYSTEM OVERVIEW

S

SPEAKER, CEILING MOUNTED FIRE ALARM VOICE

EVACUATION .

DETECTOR, SMOKESD

FIRE ALARM RELAY MODULER

NAC= NOTIFICATION APPLIANCE CIRCUIT PANEL

FIRE ALARM DRAWING INDEX

SHEET DESCRIPTION

FA001 FIRE ALARM LEGEND

FA101 LEVEL B PLAN - FIRE ALARM PLAN

FA102 LEVEL 1 PLAN - FIRE ALARM PLAN

FA103 LEVEL 2 PLAN - FIRE ALARM PLAN

FA501 FIRE ALARM DETAILS

FA601 FIRE ALARM DIAGRAM

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

ENGINEER ARCHITECT/ENGINEER OF RECORD

WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH

PROJECT NORTH

www.abovegroupinc.com

COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

/3

/2

:2

:1

P

M B

IM

/0

V A

P ro v id e n c e M e n ta l H e a lt h

B u ild in g

P H

/0

V A

P ro v id e n c e

M H

C P

H

R

D iv

.r v t

FA001

650-347

PROVIDENCE VAMC MENTAL

HEALTH PHASE 2

PROVIDENCE, RI

JFR CVMFEB 04 2022

CONSTRUCTION

DOCUMENTS

FIRE ALARM LEGEND

FULLY SPRINKLERED

JOHN F. RAINE, P.E.

MD License #41408Revisions: Revision Description Date:

G-2A1 G-3

R E

F

P

S

S

S

S

S

S

S

S

S

SD

R

2-B

E.5

2-D

2-A

2-C

2-E

2-12-2.12-22-3

2-4

2-5

2-6

2-7

2-8

2-F

CONSULT ROOM

PRINTER

034B

STORAGE

CONSULT ROOM

CONSULT ROOM

OFFICE (TRIPLE)

OFFICE (TRIPLE)

TEAM RM

STAFF TOILET

CORRIDOR

034A

HAC

STAIR 3

CORRIDOR

OFFICE (TRIPLE)

OFFICE (TRIPLE)

ELEC. CL.

OFFICE (DOUBLE)

VETERAN W.S.

OFFICE (DOUBLE)

CONSULT ROOM

OFFICE

OFFICE

CHIEF OFFICE

PUBLIC TOILET

MSA

WAITING AREA

45CD

15CD

15CD

15CD

75CD

30CD

15CD

N A

C

DRAWING NOTES:

1. COORDINATE EXACT LOCATION OF CEILING AND WALL MOUNTED FIRE ALARM DEVICES WITH ALL

OTHER UTILITIES AND ARCHITECTURAL PLANS PRIOR TO CONTRUCTION.

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

ENGINEER ARCHITECT/ENGINEER OF RECORD

WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH

PROJECT NORTH

www.abovegroupinc.com

COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

/8

/2

:4

:3

P M

B

IM

/0

V A

P ro v id e n c e M e n ta l H e a lt h

B u ild in g

P H

/0

V A

P ro v id e n c e

M H

C P

H

R

D iv

.r v t

FA101

650-347

PROVIDENCE VAMC MENTAL

HEALTH PHASE 2

PROVIDENCE, RI

JFR CVMFEB 04 2022

CONSTRUCTION

DOCUMENTS

LEVEL B PLAN - FIRE ALARM PLAN

FULLY SPRINKLERED

JOHN F. RAINE, P.E.

MD License #41408

1/4" = 1'-0" F1

LEVEL B PLAN - FIRE ALARM

0 2' 4' 8' 12'

1/4" = 1'-0"

Revisions: Revision Description Date:

1 FIRE CURTAINS TBD

PROVIDE FIRE ALARM CONTROL RELAY MODULE FOR WINDOW FIRE CURTAIN. COORDINATE EXACT

LOCATION AND REQUIREMENTS WITH FIRE CURTAIN VENDOR PRIOR TO ROUGH-IN.

EXISTING PHASE 1. NO WORK IN THIS AREA, UNLESS OTHERWISE NOTED.

CODED NOTES:

P

S

S

S

S

S

S

S

S

SD

R

2-B

E.5

2-D

2-A

2-C

2-E

2-12-2.12-22-3

2-4

2-5

2-6

2-7

2-8

2-F

WAITING AREA

MSA

PUBLIC TOILET

CORRIDOR

GROUP THERAPY

GROUP THERAPY

OFFICE

OFFICE

OFFICE

COUPLE'S THERAPY

COUPLE'S THERAPY

OFFICE

OFFICE

PRINTER

131A

TELEDATA

OFFICE

ELEC. CL.

OFFICE

OFFICE

SECTION CHIEF

STAFF TOILET

STAIR 3

LOUNGE, STAFF

COUPLE'S THERAPY

30CD

15CD

75CD

45CD

30CD

15CD

75CD

45CD

N A

C

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

ENGINEER ARCHITECT/ENGINEER OF RECORD

WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH

PROJECT NORTH

www.abovegroupinc.com

COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

/8

/2

:4

:3

P M

B

IM

/0

V A

P ro v id e n c e M e n ta l H e a lt h

B u ild in g

P H

/0

V A

P ro v id e n c e

M H

C P

H

R

D iv

.r v t

FA102

650-347

PROVIDENCE VAMC MENTAL

HEALTH PHASE 2

PROVIDENCE, RI

JFR CVMFEB 04 2022

CONSTRUCTION

DOCUMENTS

LEVEL 1 PLAN - FIRE ALARM PLAN

FULLY SPRINKLERED

JOHN F. RAINE, P.E.

MD License #41408

1/4" = 1'-0" F1

LEVEL 1 PLAN - FIRE ALARM

0 2' 4' 8' 12'

1/4" = 1'-0"

DRAWING NOTES:

1. COORDINATE EXACT LOCATION OF CEILING AND WALL MOUNTED FIRE ALARM DEVICES WITH ALL

OTHER UTILITIES AND ARCHITECTURAL PLANS PRIOR TO CONTRUCTION.

Revisions: Revision Description Date:

1 FIRE CURTAINS TBD

PROVIDE FIRE ALARM CONTROL RELAY MODULE FOR WINDOW FIRE CURTAIN. COORDINATE EXACT

LOCATION AND REQUIREMENTS WITH FIRE CURTAIN VENDOR PRIOR TO ROUGH-IN.

EXISTING PHASE 1. NO WORK IN THIS AREA, UNLESS OTHERWISE NOTED.

CODED NOTES:

P

S

S

S

S

S

S

S

S

S

S

SD

S

R

2-B

E.5

2-D

2-A

2-C

2-E

2-12-2.12-22-3

2-4

2-5

2-6

2-7

2-8

2-F

FIRE ALARM

NAC

WAITING AREA

PUBLIC TOILET

STAFF TOILET

N.P. OFFICE

N.P. OFFICE

N.P. OFFICE

CORRIDOR

CHIEF OFFICE

OFFICE

OFFICE

OFFICE/CONSULT

OFFICE

OFFICE/CONSULT

CORRIDOR

ELEC. RM.

HAC

N.P. OFFICE

N.P. OFFICE

N.P. OFFICE

MECH. RM.

STAIR 3

PRINTER

204A

AHU-39-2-02

45CD

45CD

45CD

45CD

45CD

45CD

15CD

45CD

15CD

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

ENGINEER ARCHITECT/ENGINEER OF RECORD

WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH

PROJECT NORTH

www.abovegroupinc.com

COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

/8

/2

:4

:3

P M

B

IM

/0

V A

P ro v id e n c e M e n ta l H e a lt h

B u ild in g

P H

/0

V A

P ro v id e n c e

M H

C P

H

R

D iv

.r v t

FA103

650-347

PROVIDENCE VAMC MENTAL

HEALTH PHASE 2

PROVIDENCE, RI

JFR CVMFEB 04 2022

CONSTRUCTION

DOCUMENTS

LEVEL 2 PLAN - FIRE ALARM PLAN

FULLY SPRINKLERED

JOHN F. RAINE, P.E.

MD License #41408

1/4" = 1'-0"F1

LEVEL 2 PLAN - FIRE ALARM

0 2' 4' 8' 12'

1/4" = 1'-0"

DRAWING NOTES:

1. COORDINATE EXACT LOCATION OF CEILING AND WALL MOUNTED FIRE ALARM DEVICES WITH ALL

OTHER UTILITIES AND ARCHITECTURAL PLANS PRIOR TO CONTRUCTION.

DUCT SMOKE DETECTOR FURNISHED AND CONNECTED BY ELECTRICAL CONTRACTOR, MOUNTED IN

DUCTWORK BY MECHANICAL CONTRACTOR.

PROVIDE FIRE ALARM CONTROL RELAY MODULE FOR WINDOW FIRE CURTAIN. COORDINATE EXACT

LOCATION AND REQUIREMENTS WITH FIRE CURTAIN VENDOR PRIOR TO ROUGH-IN.

EXISTING PHASE 1. NO WORK IN THIS AREA, UNLESS OTHERWISE NOTED.

CODED NOTES:

Revisions: Revision Description Date:

1 FIRE CURTAINS TBD

1'-0" MAX.

5'-0" MIN. TO

6'-6" MAX.

FINISHED

FLOOR

SPEAKER

DEVICE

7'-6" TO TOP

OF DEVICE,

OR

0'-6" BELOW

FINISHED CEILING,

WHICHEVER IS

LOWER

6'-8" MIN. TO 8'-0" MAX.

FROM STROB LENS TO

FLOOR, OR

WITHIN 0'-6" OF

FINISHED CEILING,

WHICHEVER IS

LOWER

STROBE

DEVICE

SPEAKER/STROBE

COMBINATION

DEVICE

FIRE ALARM CONTROL

PANEL OR EMERGENCY

VOICE PANEL

ANNUCIATOR

PANEL OR

TERMINAL

CABINET

MANUAL PULL

STATION

5'-6"

3'-10" FROM

OPERATING

HANDLE

TO FLOOR

5'-0" MAX.

FROM EXIT OPENING

0'-4" MIN. 3'-0" MIN.

SMOKE/HEAT

DETECTOR

MOUNT DETECTOR

ON APPROVED BOX 6'-0" MAX. LENGTH FLEXIBLE RACEWAY TO DEVICE MOUNTED

ON SUSPENDED CEILING

AIR SUPPLY DIFFUSER OR

RETURN AIR OPENING

JUNCTION BOX

CONDUIT

INSTALL PER NATIONAL

ELECTRIC CODE

FLOOR-CEILING

ASSEMBLY

SUSPENDED

CEILING

SMOKE

DETECTOR

1'-0" MAX.

FINISHED

FLOOR

SUSPENDED

CEILING

HEAT

DETECTOR

0'-4" MIN.

0'-4" MIN

HEAT

DETECTOR

DO NOT LOCATE

DETECTOR WITHIN

THIS AREA

HEAT DETECTOR MOUNTING

PLACEMENT REQUIREMENTSNOTES:

1. MOUNT FIRE ALARM DEVICES ON APPROVED BOXES.

N.T.S.

FIRE ALARM DEVICE MOUNTING DETAIL

E5

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

ENGINEER ARCHITECT/ENGINEER OF RECORD

WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH

PROJECT NORTH

www.abovegroupinc.com

COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

/3

/2

:2

:1

P

M B

IM

/0

V A

P ro v id e n c e M e n ta l H e a lt h

B u ild in g

P H

/0

V A

P ro v id e n c e

M H

C P

H

R

D iv

.r v t

FA501

650-347

PROVIDENCE VAMC MENTAL

HEALTH PHASE 2

PROVIDENCE, RI

JFR CVMFEB 04 2022

CONSTRUCTION

DOCUMENTS

FIRE ALARM DETAILS

FULLY SPRINKLERED

NEW

FIRE ALARM

BOOSTER PANEL

"NAC"

LEVEL 2

R R

P

TYPICAL CONTROL RELAYS

INDICATING DEVICES

TYPICAL INITIATION DEVICES

ROOF

SDHD

CODED NOTE:

NEW FIRE ALARM BOOSTER PANEL TO INTERFACE WITH

EXISTING FIRE ALARM SYSTEM IN BUILDING 38.

EXISTING BUILDING #38 PH-1

FIRE ALARM NETWORK

(NOTIFIER NFS2-640)

CLASS B WIRING TYPICAL,

UNLESS OTHERWISE NOTED.

CLASS X WIRING. GENERAL NOTE: EXISTING FIRE ALARM SYSTEM RESPONSE

WILL NOT BE ALTERED BY THIS PROJECT. MAINTAIN

EXISTING FIRE ALARM SYSTEM RESPONSE.

LEVEL 1

P

INDICATING DEVICES

TYPICAL INITIATION DEVICESSDHD

LEVEL B

P

INDICATING DEVICES

TYPICAL INITIATION DEVICESSDHD

S

S

S

LEVEL 1 FIRE ALARM

NAC PANEL.

LEVEL B FIRE ALARM

NAC PANEL.

N.T.S.

FIRE ALARM RISER DIAGRAM2

F7

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

ENGINEER ARCHITECT/ENGINEER OF RECORD

WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH

PROJECT NORTH

www.abovegroupinc.com

COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

/3

/2

:2

:1

P

M B

IM

/0

V A

P ro v id e n c e M e n ta l H e a lt h

B u ild in g

P H

/0

V A

P ro v id e n c e

M H

C P

H

R

D iv

.r v t

FA601

650-347

PROVIDENCE VAMC MENTAL

HEALTH PHASE 2

PROVIDENCE, RI

JFR CVMFEB 04 2022

CONSTRUCTION

DOCUMENTS

FIRE ALARM DIAGRAM

FULLY SPRINKLERED

File details come from the government source that posted it. Updated .