This document provides details for a federal contract solicitation for construction services. The Department of Veterans Affairs, through its Program Contracting Activity Central office, is seeking proposals for a firm-fixed-price contract to complete the Design-Bid-Build Construct Mental Health Phase 2 project at the Providence VA Medical Center in Providence, Rhode Island. The selected contractor will furnish all labor, materials, equipment, tools and supervision necessary for general construction, alterations, civil site work, finishes, HVAC, electrical, plumbing, fire alarm and suppression, security and other work required based on provided drawings and specifications. The solicitation number is 36C77623R0039 and proposals are due in response to this opportunity to construct additional mental health facilities at the Providence VAMC as the second phase of that project. The Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas is the contracting agency.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CG
1 HR FIRE RATING:
PLANS & SECTIONS
PLAN & SECTION DETAILS
LEGEND:
NOTE: SEE SHEET GI002 FOR GENERAL NOTES.
SMOKE PARTITION:
PLAN & SECTION DETAILS
2-8
2-F
E4
E1
C3
5" STRUCTURAL COLUMN.
SEE STRUCTURAL DWGS.
STRUCTURAL CROSS-
BRACE BELOW. SEE
STRUCTURAL DWGS.
/8
M4A
MTL STUD TRACK
SECURED TO CROSS-
BRACE BELOW
CONT. VERTICAL
SEALANT AND BACKER
ROD, TYP.
1HR FIRE RATING AT
STAIR SHAFT TO EXTEND
TO EXTERIOR SIDE OF
WALL, TYP.
MASONRY ANCHOR
EXTERIOR WALL AS
SCHEDULED
2-8
5"
M4A
M1A
C3
FOUNDATION WALL. SEE
STRUCTURAL DWGS
SELF ADHERED SHEET
WATERPROOFING
2" RIGID INSULATION
DRAINAGE MAT
2-6
2-E
2-F
3" 3"
E1
E2
M6
M2A
BRICK BANDING BELOW, TYP
MASONRY ANCHOR
EXTERIOR WALL AS SCHEDULED
1" TYP
2-A
2-2.1
M4A
M2A
M4A
M2A
CORNER GUARD AT ALL
OUTSIDE CORNERS
5/8" GWB OVER 7/8"
HAT CHANNEL
CONCRETE PIER. SEE
STRUCTURAL DWGS
M4
FOUNDATION WALL. SEE
STRUCTURAL DWGS
BATTS INSULATION,
TYP
SELF ADHERED SHEET
WATERPROOFING
2" RIGID INSULATION
DRAINAGE MAT
CORNER BEAD, TYP
2-6
2-E
2-F
3" 3"
E1
E2
M6
M2A
1/2" BACKER ROD AND
SEALANT
FILL CAVITY WITH SOLID GROUT
EXTERIOR WALL AS SCHEDULED
PRECAST EXTERIOR WALL
BASE
AE204
2-1
2-B
D9
SELF ADHERED SHEET
WATERPROOFING
2" RIGID INSULATION
DRAINAGE MAT
FOUNDATION WALL. SEE
STRUCTURAL DWGS
M4A
M2A
M2A
EXISTING FOUNDATION
WALL
CORNER GUARD AT ALL
OUTSIDE CORNERS
5/8" GWB OVER 7/8"
HAT CHANNEL
CONCRETE PIER. SEE
STRUCTURAL DWGS
BATTS INSULATION,
TYP
CORNER BEAD, TYP
PATCH, REPAIR AND
FINISH EXISTING GWB
SURFACE AS REQUIRED
TO MATCH EXISTING
SCHEDULED DOOR
WOOD BLOCKING
M4A
5/8" GWB OVER HAT
CHANNEL, TYP
PATCH, REPAIR AND FINISH
EXISTING GWB SURFACE AS
REQUIRED TO MATCH EXISTING
SCHEDULED DOOR
EXISTING
FOUNDATION WALL
1"
VIF
+/- 7 3/8"
WOOD BLOCKING
WOOD LOOK WALL
PANEL SYSTEM
/4
"ALUMINUM
EDGE TRIM
SIDING SYSTEM
MOUNTING CLIP &SYSTEM
SPECIFIC FASTENER,
ATTACHED TO PLYWOOD
BACKER
4" WIDE 5/58" FIRE RATED
PLYWOOD (SPACE 20" O.C.),
PAINT BACKER BLACK TO
HIDE GAPS AT VERTICAL BUTT
JOINTS BETWEEN PLANKS
2-8
E4
M4A
C3
E2
1/2" BACKER ROD
AND SEALANT
3 5/8"
4 5/8"
CONT. BACKER
ROD AND SEALANT
MASONRY ANCHOR
EXTERIOR WALL AS
SCHEDULED
2-6
2-A
E2
M6B
M4A
PROVIDE SPRAY FOAM INSULATION TO
MATCH THICKNESS OF SPRAY FOAM IN
EXTERIOR ASSEMBLY
WOOD BLOCKING
PROVIDE CONTINUOUS SMOKE SEAL
JOINT, TYP.
STEEL COLUMN AND CROSS-BRACING.
SEE STRUCTURAL DWGS.
4" WALL EXPANSION JOINT.
BASIS OF DESIGN PRODUCT:
C-S GROUP MODEL FWSC-400
SCHEDULED DOOR
EXISTING PHASE 1
WALL ASSEMBLY
5/8" TYPE X GWB ON
EXISTING WALL (UL V497)
FIRESTOP ALL
PENETRATIONS
ALTER EXISTING WALL
TO ACHIEVE 1HR FIRE
RATING
M4A
4"
1"
DOOR THRESHOLD BELOW
EXTEND DOOR THRESHOLD BEYOND
WALL EXPANSION JOINT, MIN 4"
SLAB EXPANSION JOINT BELOW
WOOD LOOK WALL
PANEL SYSTEM
ALUMINUM EDGE TRIM
SIDING SYSTEM MOUNTING
CLIP &SYSTEM SPECIFIC
FASTENER, ATTACHED TO
PLYWOOD BACKER
4" WIDE 5/58" FIRE RATED
PLYWOOD (SPACE 20" O.C.),
PAINT BACKER BLACK TO HIDE
GAPS AT VERTICAL BUTT
JOINTS BETWEEN PLANKS
/4
2-A
2-7
SELF ADHERED SHEET
WATERPROOFING
2" RIGID INSULATION
DRAINAGE MAT
CORNER GUARD AT ALL
OUTSIDE CORNERS
5/8" GWB OVER 7/8"
HAT CHANNEL
CONCRETE PIER. SEE
STRUCTURAL DWGS
FOUNDATION WALL. SEE
STRUCTURAL DWGS
BATTS INSULATION,
TYP
CORNER BEAD, TYP
2-A
2-5 CORNER GUARD AT ALL
OUTSIDE CORNERS
5/8" GWB OVER 7/8"
HAT CHANNEL
CORNER BEAD, TYP
SELF ADHERED SHEET
WATERPROOFING
2" RIGID INSULATION
DRAINAGE MAT
FOUNDATION WALL. SEE
STRUCTURAL DWGS
M4A
M2A
2-8
2-C M4A
C3
M6
3/4" 5"
MASONRY ANCHORS
BACKER ROD AND
SEALANT AT ALL SIDES
DOOR AND FRAME AS
SCHEDULED
GWB RETURN AT
DOOR JAMB, TYP.
CORNER BEAD AT ALL
OUTSIDE CORNERS,
J BEAD AT ALL GWB
RETURNS
WOOD BLOCKING
CONTINUOUS SEALANT
2-8
E4
M4A
C3
E2
1/2" BACKER ROD AND
SEALANT
FILL CAVITY WITH SOLID GROUT
3 5/8"
5"
CONT. BACKER
ROD AND SEALANT
STRUCTURAL CROSS-
BRACE BELOW. SEE
STRUCTURAL DWGS.
MTL STUD TRACK
SECURED TO CROSS-
BRACE BELOW
PRECAST EXTERIOR WALL BASE
EXTERIOR WALL AS
SCHEDULED
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD
WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH
PROJECT NORTH
/8
/2
:1
:4
A M
U A u to d e sk A u to sa ve s \R e vi t\
V
A M
C P
R O
V
ID
E N
C E
M H
C P
II
A R
C H
R b e n
.s to o d le yM
Q F
.r vt
AE501
650-347
NEW MENTAL HEALTH BUILDING -
PHASE 2
830 CHALKSTONE AVE PROVIDENCE, RI 02908
RBB BRS04 FEB 2022
100% CD SUBMISSIONPLAN DETAILS
FULLY SPRINKLEREDVA RI FACILITIES MANAGEMENT
SERVICE
1 1/2" = 1'-0"
B1 LEVEL B - STAIR 3 EXTERIOR WALL TRANSITION
1 1/2" = 1'-0"
B3 LEVEL B - STAIR 3 CORNER TRANSITION
1 1/2" = 1'-0"
B5 LEVEL B - FACADE TRANSITION
1 1/2" = 1'-0"
D1 LEVEL B - FOUNDATION PIER
1 1/2" = 1'-0"
D5 LEVEL B - FACADE TRANSITION @ PRECAST PANEL
1 1/2" = 1'-0"
B7 LEVEL B - FOUNDATION PIER
1 1/2" = 1'-0"
D9 LEVEL B - OPENING JAMB @ PHASE 2 ENTRY
1 1/2" = 1'-0"
F3 LEVEL 1 - STAIR 3 CORNER TRANSITION
1 1/2" = 1'-0"
F5 LEVEL 2 - 1 HR FIRE RATED PARTITION TERMINATION
1 1/2" = 1'-0"
F9 LEVEL 1 - OPENING JAMBE @ PHASE 2 ENTRY
1 1/2" = 1'-0"
D7 LEVEL B - TYP. CONCRETE PIER DETAIL 1
1 1/2" = 1'-0"
F7 LEVEL B - TYP. CONCRETE PIER DETAIL 2
1 1/2" = 1'-0"
D3 LEVEL B PLAN - STAIR 3 JAMB DETAIL
1 1/2" = 1'-0"
F1 LEVEL 1 - STAIR 3 CORNER TRANSITION @ PRECAST
Revisions: Revision Description Date:
C G
CG
C G
C G
1 HR FIRE RATING:
PLANS & SECTIONS
PLAN & SECTION DETAILS
LEGEND:
NOTE: SEE SHEET GI002 FOR GENERAL NOTES.
SMOKE PARTITION:
PLAN & SECTION DETAILS
2-A
2-5
E2
M8
PROVIDE SPRAY FOAM INSULATION TO
MATCH THICKNESS OF SPRAY FOAM IN
EXTERIOR ASSEMBLY
WOOD BLOCKING
STEEL COLUMN AND CROSS-BRACING.
SEE STRUCTURAL DWGS.
M2A
M2A
CORNER GUARD, TYP AT CORNERS
1' - 2"
2-2
2-E
E2
M4A
MASONRY ANCHOR
EXTERIOR WALL
AS SCHEDULED
SEE ELEVATIONS FOR
LOCATIONS AND ALIGNMENT
OF CMU FACADE CORNERS
AND COURSING ALIGNMENT
STRUCTURAL COLUMN.
SEE STRUCTURAL DWGS.
STRUCTURAL CROSS-BRACE
BELOW. SEE STRUCTURAL
DWGS.
MTL STUD TRACK SECURED
TO CROSS-BRACE BELOW
2-8
M6B
C3
M6A
5"
WOOD BLOCKING
PROVIDE CONTINUOUS SMOKE SEAL
JOINT, TYP.
STEEL COLUMN AND CROSS-
BRACING. SEE STRUCTURAL DWGS.
CORNER GUARD, TYP AT
CORNERS
M4A
M4A
M4A
M4A
M4
M6A
M4
E Q
E Q
TILE BACKSPLASH, SEE
INTERIOR DETAILS
DRINKING FOUNTAIN
1' - 6 5/8"
/8
/4
1' - 2 5/8"
.0
M4A
2-6
2-E
2-F
3 5/8"
E1
E2
M4A
M4A
BRICK VENEER BANDING
MASONRY ANCHOR
EXTERIOR WALL AS SCHEDULED
BRICK VENEER BELOW
1"
CORNER GUARD, TYP
WOOD BLOCKING, TYP
FULLY GROUTED CAVITY
BELOW GRADE
FOUNDATION WALL,
SEE STRUCT. DWGS.
CMU WALL, AS SCHEDULED
SELF ADHERED SHEET
WATERPROOFING
2" RIGID INSULATION
DRAINAGE MAT
E4
1 1/2" MTL STUD @ 16" OC
4" WALL EXPANSION JOINT.
BASIS OF DESIGN PRODUCT:
C-S GROUP MODEL FWSC-400
SCHEDULED DOOR
PATCH, REPAIR AND
FINISH EXISTING
PARTITION AS
REQUIRED TO MATCH
EXISTING
M4A 4"
EXPANSION
JOINT BELOW
SLAB EXPANSION
JOINT BELOW
WOOD LOOK WALL
PANEL SYSTEM
ALUMINUM EDGE TRIM
SIDING SYSTEM MOUNTING
CLIP &SYSTEM SPECIFIC
FASTENER, ATTACHED TO
PLYWOOD BACKER
4" WIDE 5/58" FIRE RATED
PLYWOOD (SPACE 20" O.C.),
PAINT BACKER BLACK TO HIDE
GAPS AT VERTICAL BUTT
JOINTS BETWEEN PLANKS
/4
PRECAST BASE - PROFILE 'B'
PRECAST ANCHORS
FOUNDATION WALL,
SEE STRUCT. DWGS.
SELF ADHERED SHEET
WATERPROOFING
2" RIGID INSULATION
DRAINAGE MAT
FULLY GROUT CAVITY
G
/4
M
IN4
1' - 10 5/8"
MIN
4"
M4A
M4A
SEE TYP SECTION
DETAILS FOR EDGE OF
FLOOR SLAB BELOW
EXISTING PHASE 1
EXTERIOR WALL
EXISTING METAL WALL PANEL
TO MODIFIED/REINSTALLED
AS REQUIRED. COORDINATE
WITH REMOVALS OF AD-101
MICROSPHERE-MODIFIED
100% ACRYLIC-
IMPREGNATED PRE
COMPRESSED FOAM. BASIS
OF DESIGN PRODUCT:
EMSEAL COLORSEAL
WATERTIGHT FACTORY
APPLIED SILICONE BELLOW.
FIELD APPLY CORNER BEAD,
BOTH SIDES. BASIS OF
DESIGN PRODUCT: EMSEAL
COLORSEAL
BENT BREAK METAL FILLER
PANEL, FULL HEIGHT TO
MATCH CURTAIN WALL
MULLION. EXTEND MIN 4"
BEHIND FACE OF CURTAIN
WALL MULLION AND SEALED
TO ROOF EXPANSION JOINT
ABOVE
FILL CAVITY WITH SPRAY
FOAM INSULATION
7" W LVL WINDOW BUCK
#12 TEK SCREWS SPACED
AT 6" O.C.
SCHEDULED CURTAIN WALL
WRAP AVB OVER
SHEATHING, TYP
MTL STUD FRAMING
CORNER POST ATTACHED
TO EDGE OF SLAB, ALL
LEVELS
BACKER ROAD AND SEALANT
*NOTE: FOR MORE INFORMATION ON ROOF TO WALL TRANSITION OF EXPANSION JOINT, SEE TYPICAL DETAIL /F1 AE608
BACKER ROD AND SEALANT
ALL SIDES
WOOD LOOK WALL
PANEL SYSTEM
ALUMINUM OUTSIDE
CORNER TRIM
ALUMINUM EDGE TRIM
SIDING SYSTEM
MOUNTING CLIP
&SYSTEM SPECIFIC
FASTENER, ATTACHED
TO PLYWOOD BACKER
4" WIDE 5/58" FIRE RATED
PLYWOOD (SPACE 20"
O.C.), PAINT BACKER
BLACK TO HIDE GAPS AT
VERTICAL BUTT JOINTS
BETWEEN PLANKS
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD
WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH
PROJECT NORTH
/8
/2
:1
:5
A M
U A u to d e sk A u to sa ve s \R e vi t\
V
A M
C P
R O
V
ID
E N
C E
M H
C P
II
A R
C H
R b e n
.s to o d le yM
Q F
.r vt
AE502
650-347
NEW MENTAL HEALTH BUILDING -
PHASE 2
830 CHALKSTONE AVE PROVIDENCE, RI 02908
RBB BRS04 FEB 2022
100% CD SUBMISSIONPLAN DETAILS
FULLY SPRINKLEREDVA RI FACILITIES MANAGEMENT
SERVICE
1 1/2" = 1'-0"
F3 LEVEL 1 - TYP. DETAIL @ EXTERIOR WALL COLUMN
1 1/2" = 1'-0"
B5 LEVEL 1 - TYP. EXTERIOR CORNER
1 1/2" = 1'-0"
D5 LEVEL 2 - TYP. RATED PARTITION @ STAIR 3
1 1/2" = 1'-0"
D7 LEVEL 2 - DRINKING FOUNTAIN ALCOVE
1 1/2" = 1'-0"
F7 LEVEL 2 - EXTERIOR WALL CORNER @ BRICK COURSING
1 1/2" = 1'-0"
B3 LEVEL B - STAIR 3 FOUNDATION WALL TRANSITION
1 1/2" = 1'-0"
F5 LEVEL 2 - EXPANSION JOINT
1 1/2" = 1'-0"
D3 TYP FOUNDATION TO PRECAST PANEL
1 1/2" = 1'-0"
F1 TYP CURTAIN WALL JAMB @ EXPANSION JOINT - WEST FLR. 1
& 2
1' - 1"
3/4" PLYWOOD SHEATHING, TYP.
FILL W/RIGID INSULATION
BLOCKING, TYP.
FACE OF PLYWOOD
FACE OF INSULATION
ALIGN
ALIGN
NOTE: ANCHOR PARAPET LADDER FRAMING
TO STUD WALL. DO NOT ANCHOR TO VENEER.
LEVEL B
73' - 0"
2-A
BASEMENT LEVEL
73' - 0"
1" RIGID INSULATION
CONTINUOUS VAPOR
RETARDER UNDER SLAB
2" RIGID INSULATION TO BE CONTINUOUS
UNDER SLAB AND TO TOP OF FOOTING
SELF ADHERED SHEET
WATERPROOFING
2" RIGID INSULATION
DRAINAGE MAT
PERIMETER DRAIN,
SEE CIVIL DWGS.
CONTINUOUS WATERSTOP
CONTINUE VAPOR RETARDER PAST
TOP OF SLAB, SEAL TO WALL AND
COUNTERFLASH
CONCRETE FOUNDATION
WALL, SEE STRUCT. DWGS.
CONCRETE FOOTING,
SEE STRUCT. DWGS.
WALL TYPE AS SCHEDULED
CONCRETE SLAB, SEE STRUCT. DWGS.
CRUSHED STONE, SEE
STRUCT. DWGS.
2-E
SELF ADHERED SHEET
WATERPROOFING
2" RIGID INSULATION
DRAINAGE MAT
PRECAST BASE - PROFILE 'B'
FILL CAVITY WITH
SOLID GROUT
MASONRY ANCHORS
CONTINUOUS SSTL THROUGH-
WALL FLASHING TO EXTEND UP
WALL 8" MIN. HOLD FLASHING
BACK 1/2" FROM PRECAST
FACE AND SET BOTTOM LEG IN
FULL BED OF MASTIC, TYP.
COUNTER FLASH WITH AIR
BARRIER MEMBRANE, TYP.
PERIMETER DRAIN
1" RIGID
INSULATION
VAPOR RETARDER TO BE
CONTINUOUS UNDER SLAB
2" RIGID INSULATION
TO BE CONTINUOUS
UNDER SLAB AND TO
TOP OF FOOTING
CRUSHED STONE, SEE
STRUCT. DWGS.
CONTINUOUS WATERSTOP
CONTINUE VAPOR
RETARDER PAST TOP
OF SLAB AND TAPE
TO WALL
MORTAR NET, MIN
10" HIGH TYP.
2 1/2" RIGID INSULATION
WEEP
CONCRETE SLAB,
SEE STRUCT.
DWGS.
WALL BASE AS
SCHEDULED
GRADE, SEE CIVIL DWGS.
PRECAST ANCHOR, TYP.
BRICK OR CMU VENEER
V A
R
IE
S
ROOF
113' - 8"
2-E
MASONRY ANCHOR
VENT
PRECAST COPING,
PROFILE 'A'
METAL FLASHING
W/ DRIP EDGE
TWO PIECE METAL
FLASHING W/ DRIP EDGE
PRECAST COPING
ANCHOR
ROOF AS SCHEDULED
RUN ROOF AVB OVER
PARAPET AND LAP
OVER WALL AVB
3/4" EXTERIOR
PLYWOOD OVER 2 1/2"
RIGID INSULATION
TERMINATION BAR
AND SEALANT
P.T. CANT
E2
STRUCTURAL STEEL,
SEE STRUC. DWGS.
METAL ROOF DECK,
SEE STRUC. DWGS.
TOP CFMF TRACK
AND PARAPET TO
BE DESIGNED TO
SUPPORT LOADS
FROM PRECAST
COPING
CMU COURSING,
SEE SECTION
AND ELEVATION
FILL WITH BATT
INSULATION, TYP.
BRICK COURSING,
SEE SECTION AND
ELEVATION
CMU BEYOND
1"
AE510
A8
Sim
E1
DEFLECTION TRACK
FILL CAVITY WITH
MINERAL FIBER
INSULATION
ROOF
113' - 8"
2-8
MASONRY ANCHOR
VENT
PRECAST COPING,
PROFILE 'A'
METAL FLASHING
W/ DRIP EDGE
TWO PIECE METAL
FLASHING W/ DRIP EDGE
PRECAST COPING
ANCHOR
ROOF AS SCHEDULED
RUN ROOF AVB OVER
PARAPET AND LAP
OVER WALL AVB
3/4" EXTERIOR
PLYWOOD OVER 2 1/2"
RIGID INSULATION
TERMINATION BAR
AND SEALANT
P.T. CANTE2
STRUCTURAL STEEL,
SEE STRUC. DWGS.
METAL ROOF DECK,
SEE STRUC. DWGS.
AE510
A8
Sim
TOP CFMF TRACK
AND PARAPET TO
BE DESIGNED TO
SUPPORT LOADS
FROM PRECAST
COPING
CMU COURSING,
SEE SECTION
AND ELEVATION
FILL WITH BATT
INSULATION, TYP.
DEFLECTION TRACK
FILL CAVITY WITH
MINERAL FIBER
INSULATION
ROOF
113' - 8"
2-E2-F
ROOF AS SCHEDULED
STEEL BEAMS, SEE
STRUCT. DWGS.
METAL ROOF DECK, SEE STRUCT. DWGS.
P.T. CANT
STEEL PLATE, SEE STRUCT. DWGS.
TWO PIECE METAL THROUGH-WALL FLASHING,
RUN 8" UP WALL, TYP.
TERMINATION BAR & SEALANT
RELIEVING ANGLE ATTACHED TO BEAM
BEHIND, SEE STRUCT. DWGS. SEAL AVB
AROUND EXTERIOR WALL PENETRATION
MORTAR NET,
MIN 10" HIGH TYP.
WEEP
3/4" PLYWOOD OVER RIGID INSULATION
ALIGN W/ F.O. CMU ABOVE
E2
AE510
A8
Sim
VENT
PRECAST COPING,
PROFILE 'A'
TWO PIECE METAL FLASHING W/
DRIP EDGE
PRECAST COPING ANCHOR
RUN ROOF AVB OVER PARAPET
AND LAP OVER WALL AVB
3/4" EXTERIOR PLYWOOD OVER
2 1/2" RIGID INSULATION
TERMINATION BAR AND SEALANT
MASONRY ANCHOR
TOP CFMF TRACK AND PARAPET TO BE
DESIGNED TO SUPPORT LOADS FROM
PRECAST COPING
METAL FLASHING
W/ DRIP EDGE
VENT
BRICK COURSING, SEE
SECTION
AND ELEVATION
PROVIDE SINGLE,
CONTINUOUS METAL
FLASHING BENT AND TURNED
UP BEHIND TERMINATION BAR
TWO PIECE SNAP-
FLASHING WITH CONT.
CLEAT, LAP AND SEAL
TO ROOF MEMBRANE
WRAP AVB OVER
LADDER FRAMING, TYP
DEFLECTION TRACK,
TYP
BLOCKING
1"
E1
AE510
B8
Sim
SLOPE 1/4"/1'-0"
RIGID INSULATION, TYP
COMPRESSIBLE JOINT
FILL CAVITY WITH MINERAL
FIBER INSULATION
3/4" PLYWOOD
SHEATHING, TYP.
FILL W/ RIGID INSULATION
BLOCKING, TYP.
1' - 4"
FACE OF BRICK
FACE OF STUD
NOTE: ANCHOR PARAPET LADDER FRAMING TO
STUD WALL. DO NOT ANCHOR TO VENEER.
ALIGN
3/4" PLYWOOD
SHEATHING, TYP.
FILL W/ RIGID
INSULATION
BLOCKING, TYP.
FACE OF
PLYWOOD
FACE OF BRICK NOTE: ANCHOR PARAPET LADDER FRAMING TO
STUD WALL. DO NOT ANCHOR TO VENEER.
ALIGN
2' - 8"
/4
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD
WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH
PROJECT NORTH
/8
/2
:1
:0
A M
U A u to d e sk A u to sa ve s \R e vi t\
V
A M
C P
R O
V
ID
E N
C E
M H
C P
II
A R
C H
R b e n
.s to o d le yM
Q F
.r vt
AE510
650-347
NEW MENTAL HEALTH BUILDING -
PHASE 2
830 CHALKSTONE AVE PROVIDENCE, RI 02908
JRB BRS04 FEB 2022
100% CD SUBMISSIONSECTION DETAILS
FULLY SPRINKLEREDVA RI FACILITIES MANAGEMENT
SERVICE
3" = 1'-0" AE510
A8 TYP. PARAPET LADDER FRAMING - TYPE A
1 1/2" = 1'-0"
F1 TYPICAL FOOTING DETAIL @ RETAINING WALL
1 1/2" = 1'-0"
F8 FOUNDATION WALL DETAIL @ GRADE
1 1/2" = 1'-0"
C1 PARAPET DETAIL @ GRID 2-E
1 1/2" = 1'-0"
C3 PARAPET DETAIL @ GRID 2-8
1 1/2" = 1'-0"
C5 PARAPET DETAIL @ GRID 2-F & 2-E
3" = 1'-0"
C8 TYP. PARAPET LADDER FRAMING - TYPE C
3" = 1'-0"
B8 TYP. PARAPET LADDER FRAMING - TYPE B
/2
VENT
MASONRY ANCHOR
BRICK COURSING,
SEE SECTION
AND ELEVATION
E4
ROOF AS SCHEDULED
RUN ROOF AVB OVER
PARAPET AND LAP
OVER WALL AVB
LAP AND SEAL ROOF
MEMBRANE TO METAL
COPING W/COMPATIBLE
MEMBRANE FLASHING
AND SEALANT
TWO PIECE SNAP-FLASHING
WITH CONT. CLEAT, LAP AND
SEAL TO ROOF MEMBRANE
WRAP AVB OVER
LADDER FRAMING
STRUC. STEEL. SEE
STRUC. DWGS
ROOF EDGE BEYOND
BLOCKING
1" TYP.
/2
COMPRESSIBLE JOINT
AE510
C8
Sim
AE601
D5
Sim
METAL PANEL CLOSURE STRIP
TWO PIECE METAL THROUGH-WALL FLASHING TO EXTEND UP
WALL 8" MIN. COUNTER FLASH WITH AIR BARRIER MEMBRANE,
TYP .
TERMINATION BAR AND
SEALANT
EXISTING WALL ASSEMBLY. PROVIDE NEW
AVB AS REQUIRED FOR MODIFICATIONS
FOR NEW ROOF AND EXPANSION JOINT
INSTALLATION
ROOF AS SCHEDULED
P.T. CANT
SALVAGED METAL PANEL WITH INTEGRAL COPING: SEE
ELEVATIONS AND SECTIONS FOR SIZES AND LAYOUT
HORIZONTAL FURRING RAIL
2 1/2" RIGID INSULATION W/ TAPED SEEMS
EXISTING CONTINUOUS AIR VAPOR BARRIER,
PATCH AS NEEDED
SALVAGED VERTICAL FURRING SYSTEM FASTENED DIRECTLY
TO EXISTING CMU
CONT. EXPANSION JOINT COVER FULL PERIMETER,
LAP DOWN AND SPLICE/SEAL TO VERTICAL
EXPANSION JOINT, TYP.
BASIS OF DESIGN PRODUCT: EMSEAL ROOFJOINT
EXISTING WALL, ROOF AND PARAPET COMPONENTS TO
REMAIN. SEE REMOVAL ELEVATIONS
AND
/F1 AD201
/C1 AD201
LAP ROOFING MEMBRANE OVER EXPANSION JOINT
ASSEMBLY AND APPLY SPLICE CEMENT, TYP.
3/4" PLYWOOD OVER
3 5/8" CFM STUD AND
BATTS INSULATION
WRAP AVB OVER CFM
FRAMING, TYP
SCHEDULED PARTITION
DEFLECTION TRACK
4"
PROVIDE ADDITIONAL SPRAY FOAM
INSULATION FULL CAVITY
FILL CAVITY WITH MINERAL WOOL
INSUL, MIN R30
/4
/8
*NOTE: FOR MORE INFORMATION ON ROOF TO WALL TRANSITION OF EXPANSION JOINT, SEE TYPICAL DETAIL /F1 AE608
LEVEL B
73' - 0"
2-F
BASEMENT LEVEL
73' - 0"
WALL BASE AS
SCHEDULED
2" RIGID INSULATION
CRUSHED STONE,
SEE STRUCT.
DWGS.
CONTINUOUS 2" RIGID
INSULATION
CONCRETE SLAB,
SEE STRUCT. DWGS.
1" RIGID INSULATION
FOUNDATION WALL,
FOOTING AND BOND
BEAM, SEE STRUCT.
DWGS.
PERIMETER DRAIN,
SEE CIVIL DWGS.
FILL CAVITY WITH SOLID
GROUT BELOW GRADE
SSTL THROUGH-WALL
FLASHING TO EXTEND UP
WALL 8" MIN. COUNTER FLASH
WITH AIR BARRIER
MEMBRANE, TYP.
MORTAR NET, MIN 10" HIGH TYP.
WEEP
M
IN
V A
R
IE
S V
A R
IE
S
MASONRY ANCHOR
BRICK COURSING,
SEE ELEVATION
CONTINUOUS WATERSTOP
CONTINUE VAPOR
RETARDER PAST TOP
OF SLAB AND TAPE TO
WALL
VAPOR BARRIERGRADE, SEE CIVIL DWGS.
E1
1" TYP.
SELF ADHERED SHEET
WATERPROOFING
8"
BASEMENT LEVEL
73' - 0"
WALL BASE AS
SCHEDULED
2" RIGID INSULATION
CRUSHED STONE,
SEE STRUCT.
DWGS.
1" RIGID INSULATION
FOUNDATION WALL
AND FOOTING, SEE
STRUCT. DWGS.
PERIMETER DRAIN,
SEE CIVIL DWGS.
FILL CAVITY WITH SOLID
GROUT BELOW GRADE
SSTL THROUGH-WALL
FLASHING TO EXTEND UP
WALL 8" MIN. COUNTER FLASH
WITH AIR BARRIER
MEMBRANE, TYP.
MORTAR NET, MIN 10" HIGH TYP.
WEEP
M
IN
V A
R
IE
S V
A R
IE
S
MASONRY ANCHOR
BRICK COURSING, SEE
ELEVATION
CONTINUOUS WATERSTOP
CONTINUE VAPOR RETARDER
PAST TOP OF SLAB AND TAPE
TO WALL
EXTERIOR OUTLET,
SEE ELEC. DWGS.
GRADE, SEE CIVIL
DWGS.
E1
1" TYP.
8" 7 5/8"
2" RIGID INSULATION
DRAINAGE MAT
CONCRETE FOUNDATION
WALL, SEE STRUCT. DWGS.
SELF ADHERED SHEET
WATERPROOFING
LEVEL 2
99' - 8"
2-E
STEEL BEAMS, SEE
STRUCT. DWGS.
METAL THROUGH-WALL
FLASHING W/ DRIP EDGE TO
EXTEND UP WALL 8" MIN.
COUNTER FLASH WITH AIR
BARRIER MEMBRANE, TYP .
RELIEVING ANGLE ATTACHED TO
BEAM BEHIND, SEE STRUCT. DWGS.
SEAL AVB AROUND EXTERIOR WALL
PENETRATION
MORTAR NET,
MIN 10" HIGH TYP.
WEEP
BRICK VENEER COURSING
W/ LIPPED EDGE, TYP
SLAB EDGE SMOKE
STOP. SEE TYP.
FIRESTOPPING DETAILS
COMPOSITE
CONCRETE FLOOR,
SEE STRUCT. DWGS.
MASONRY ANCHOR
CMU RETURN BEYOND
LVL WINDOW BUCK
BACKER ROD AND
SEALANT BOTH SIDES
CFMF BOX BEAM
HEADER
STOREFRONT AS SCHEDULED
#12 TEK SCREWS
SPACED AT 6" O.C.
BRICK RETURN BEYOND
E1
TO F.O. FRAMING
4" F.O. MULLION
9"
ROOF
113' - 8"
2-8
ROOF AS SCHEDULED
STEEL BEAMS, SEE
STRUCT. DWGS.
P.T. CANT
TWO PIECE METAL
THROUGH-WALL FLASHING,
RUN 8" UP WALL, TYP.
TERMINATION BAR & SEALANT
RELIEVING ANGLE ATTACHED
TO BEAM BEHIND, SEE
STRUCT. DWGS.SEAL AVB
AROUND EXTERIOR WALL
PENETRATION
MORTAR NET,
MIN 10" HIGH TYP.
WEEP
3/4" PLYWOOD OVER RIGID
INSULATION ALIGN W/ F.O.
CMU ABOVE
P.T. CANT
ROOF SCHEDULED
E2
VENT
PRECAST COPING,
PROFILE 'A'
TWO PIECE METAL FLASHING W/
DRIP EDGE
PRECAST COPING ANCHOR
RUN ROOF AVB OVER PARAPET
AND LAP OVER WALL AVB
3/4" EXTERIOR PLYWOOD OVER
2 1/2" RIGID INSULATION
TERMINATION BAR AND SEALANT
MASONRY ANCHOR
TOP CFMF TRACK AND PARAPET TO BE
DESIGNED TO SUPPORT LOADS FROM
PRECAST COPING
METAL FLASHING
W/ DRIP EDGE
AE601
B1
Sim
DEFLECTION TRACK,
TYP.
(2) 5/8" GWB ON 4"
MTL STUD
SCHEDULED
PARTITION
AE510
A8
Sim
STRUC. STEEL. SEE
STRUC. DWGS
CEILING AS
SCEDULED
AE601
D5
Sim
ROOF
113' - 8"
2-22-2.1
ROOF AS SCHEDULED
STEEL BEAMS, SEE
STRUCT. DWGS.
P.T. CANT
TWO PIECE METAL THROUGH-
WALL FLASHING, RUN 8" UP
WALL, TYP.
TERMINATION BAR & SEALANT
RELIEVING ANGLE ATTACHED
TO BEAM BEHIND, SEE
STRUCT. DWGS.SEAL AVB
AROUND EXTERIOR WALL
PENETRATION
MORTAR NET, MIN 10" HIGH TYP.
WEEP
3/4" PLYWOOD OVER RIGID
INSULATION ALIGN W/ F.O. CMU
ABOVE
P.T. CANT
ROOF SCHEDULED
E2
VENT
PRECAST COPING,
PROFILE 'A'
TWO PIECE METAL FLASHING W/
DRIP EDGE
PRECAST COPING ANCHOR
RUN ROOF AVB OVER PARAPET
AND LAP OVER WALL AVB
3/4" EXTERIOR PLYWOOD OVER
2 1/2" RIGID INSULATION
TERMINATION BAR AND SEALANT
MASONRY ANCHOR
TOP CFMF TRACK AND
PARAPET TO BE DESIGNED
TO SUPPORT LOADS FROM
PRECAST COPING
METAL FLASHING
W/ DRIP EDGE
AE510
A8
Sim
LEVEL 2
99' - 8"
2-E
E2
STEEL BEAMS, SEE
STRUCT. DWGS.
METAL THROUGH-WALL FLASHING
W/ DRIP EDGE TO EXTEND UP WALL
8" MIN. COUNTER FLASH WITH AIR
BARRIER MEMBRANE, TYP .
RELIEVING ANGLE ATTACHED TO
BEAM BEHIND, SEE STRUCT. DWGS.
SEAL AVB AROUND EXTERIOR WALL
PENETRATION
MORTAR NET,
MIN 10" HIGH TYP.
WEEP
DEFLECTION TRACK,
TYP.
VENT
CMU VENEER COURSING W/
LIPPED EDGE, TYP
MASONRY ANCHOR
3 5/8" MTL STUD. FILL ENTIRE
FLANGE CAVITY WITH BATT
INSULATION, TYP
SLAB EDGE SMOKE
STOP. SEE TYP.
FIRESTOPPING DETAILS
COMPOSITE
CONCRETE FLOOR,
SEE STRUCT. DWGS.
9 3/4"
LEVEL 1
86' - 4"
2-A
SELF ADHERED SHEET
WATERPROOFING
2" RIGID INSULATION
DRAINAGE MAT
PRECAST BASE - PROFILE 'B'
FILL CAVITY WITH SOLID GROUT
MASONRY ANCHORS
CONTINUOUS SSTL THROUGH-
WALL FLASHING TO EXTEND UP
WALL 8" MIN. HOLD FLASHING
BACK 1/2" FROM BRICK AND CMU
FACE AND SET BOTTOM LEG IN
FULL BED OF MASTIC, TYP.
COUNTER FLASH WITH AIR
BARRIER MEMBRANE, TYP.
MORTAR NET, MIN 10" HIGH TYP.
2 1/2" RIGID INSULATION
WEEP
WALL BASE AS
SCHEDULED
GRADE, SEE CIVIL DWGS.
PRECAST ANCHOR, TYP.
BRICK VENEER
FURRING WALL
WHERE NOTED
ON PLANS
SLAB EDGE
SMOKE STOP
8"
1"
CMU VENEER BEYOND
COMPOSITE FLOOR SLAB.
SEE STRUCTURAL DWGS
PROVIDE SSTL. BASE FLASHING SET IN
FULL BED OF SEALANT AT BEAM POCKET
LOCATIONS, 6" MIN. OVERLAP BOTH SIDES.
LAP AND SEAL TO AVB
LEVEL 1
86' - 4"
2-A
SELF ADHERED SHEET
WATERPROOFING
2" RIGID INSULATION
DRAINAGE MAT
PRECAST BASE - PROFILE 'B'
FILL CAVITY WITH SOLID GROUT
CONTINUOUS SSTL THROUGH-
WALL FLASHING TO EXTEND UP
WALL 8" MIN. HOLD FLASHING
BACK 1/2" FROM BRICK AND CMU
FACE AND SET BOTTOM LEG IN
FULL BED OF MASTIC, TYP.
COUNTER FLASH WITH AIR
BARRIER MEMBRANE, TYP.
MORTAR NET, MIN 10" HIGH TYP.
2 1/2" RIGID INSULATION
WEEP
WALL BASE AS
SCHEDULED
GRADE, SEE CIVIL DWGS.
PRECAST ANCHOR, TYP.
CMU VENEER
FURRING WALL
WHERE NOTED
ON PLANS
SLAB EDGE
SMOKE STOP
8"
COMPOSITE FLOOR SLAB.
SEE STRUCTURAL DWGS
PROVIDE SSTL. BASE FLASHING SET IN
FULL BED OF SEALANT AT BEAM POCKET
LOCATIONS, 6" MIN. OVERLAP BOTH SIDES.
LAP AND SEAL TO AVB
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD
WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH
PROJECT NORTH
/8
/2
:1
:1
A M
U A u to d e sk A u to sa ve s \R e vi t\
V
A M
C P
R O
V
ID
E N
C E
M H
C P
II
A R
C H
R b e n
.s to o d le yM
Q F
.r vt
AE511
650-347
NEW MENTAL HEALTH BUILDING -
PHASE 2
830 CHALKSTONE AVE PROVIDENCE, RI 02908
JRB BRS04 FEB 2022
100% CD SUBMISSIONSECTION DETAILS
FULLY SPRINKLEREDVA RI FACILITIES MANAGEMENT
SERVICE
1 1/2" = 1'-0"
C8 PARAPET DETAIL @ STAIR 3
1 1/2" = 1'-0"
C6 PARAPET DETAIL @ EXPANSION JOINT
1" = 1'-0"
F8 SECTION DETAIL @ GRID 2-F BASE
1" = 1'-0"
F6 FOUNDATION WALL DETAIL @ STAIR 3
1 1/2" = 1'-0"
E3 BRICK VENEER RELIEVING ANGLE DETAIL
1 1/2" = 1'-0"
C1 PARAPET DETAIL @ COLUMN GRID 2-8
1 1/2" = 1'-0"
C3 PARAPET DETAIL @ COLUMN GRID 2-2.1
1 1/2" = 1'-0"
E1 CMU VENEER RELIEVING ANGLE DETAIL
1 1/2" = 1'-0"
F3 WALL BASE DETAIL @ BRICK INSET
1 1/2" = 1'-0"
F1 WALL SECTION @ GRID 2-A
LEVEL B
73' - 0"
12-1
BASEMENT LEVEL
73' - 0"
EXISTING PHASE 1
BUILDING ENVELOPE
PARTITION BEYOND. SEE
FLOOR PLAN.
DOWEL IN NEW CONCRETE SLAB
TO EXISTING FOUNDATION WALL.
SEE STRUCTURAL DWGS
CONCRETE SLAB, SEE
STRUCTURAL DWGS
VAPOR RETARDAR TO BE
CONTINUOUS UNDER SLAB
2" RIGID INSULATION TO BE
CONTINUOUS UNDER SLAB
NEW GWB RETURN
EDGE OF EXISTING
FOUNDATION WALL
BEYOND
NEW DOOR FRAME
AND SILL
NEW DOOR THRESHOLD
TO CONCEAL SLAB JOINT
2' - 2 5/8" VIF
EXISTING PHASE 1
FLOOR TO REMAIN
1"6"1"
M4A
5/8" GWB OVER HAT
CHANNEL, TYP
SCHEDULED CEILING. SEE RCP
1"
CFMF DOOR HEADER.
SEE TYP DOOR DETAILS
SCHEDULED DOOR
PATCH, REPAIR AND FINISH EXISTING GWB
SURFACE AS REQUIRED TO MATCH EXISTING
EXISTING PHASE 1
FOUNDATION WALL ASSEMBLY
ALUMINUM OUTSIDE
CORNER TRIM
WOOD LOOK PHENOLIC
WALL PANEL SYSTEM
SIDING SYSTEM MOUNTING
CLIP &SYSTEM SPECIFIC
FASTENER, ATTACHED TO
PLYWOOD BACKER
4" WIDE 5/58" FIRE RATED
PLYWOOD (SPACE 20" O.C.),
PAINT BACKER BLACK TO
HIDE GAPS AT VERTICAL BUTT
JOINTS BETWEEN PLANKS
PROVIDE 2-SIDED TAPE
TO SECURE TOP EDGE
OF PLANK WHERE CLIPS
CANNOT BE INSTALLED
HOLD PLYWOOD BACK FROM
FACE OF FINISHED PANEL 1/4" -
PROVID J-BEAD TRIM TO CONCEAL
RAW EDGE OF PLYWOOD BACKER
PROVIDE 2-SIDED TAPE TO
SECURE BOTTOM EDGE OF
PLANK WHERE CLIPS
CANNOT BE INSTALLED
LEVEL 1
86' - 4"
1' - 3" VIF3 5/8"4"
EXISTING PHASE 1
BUILDING ENVELOPE
EXISTING EXTERIOR WALL
SYSTEM TO BE REMOVED
BACK TO SHEATHING ABOVE
PRECAST BASE
EDGE OF WALL
BEYOND
CONCRETE SLAB, SEE
STRUCTURAL DWGS
EXISTING AVB TO REMAIN
CONTINUOUS
FIRESTOPPING. SEE
DETAIL
EXISTING 1HR RATED
HOLLOW CORE SLAB
EXISTING PRECAST TO
REMAIN
PARTITION WALL AS
SCHEDULED
1"
EXISTING CONTINUOUS
FIRE STOPPING
45 MIN FIRE RATED
DOOR AND FRAME
EXISTING CONCRETE
STEM WALL TO BE
REMOVED ABOVE
LEVEL 1 WHERE
REQUIRED, SEE
STRUCTURAL DWGS
WALL EXPANSION
JOINT BEYOND
NEW DOOR THRESHOLD
TO CONCEAL SLAB JOINT
10"
/B4 GI003
1"
LEVEL 2
99' - 8"
12-1
EXISTING PHASE 1
BUILDING ENVELOPE
EXISTING INSULATION,
SHEATHING AND METAL
PANEL TO BE REMOVED
EDGE OF WALL
BEYOND
COORDINATE REQUIRED
CONCRETE SLAB RECESS WITH
EXPANSION JOINT, BOTH SIDES.
SEE STRUCTURAL DWGS
EXISTING AVB TO REMAIN
DOOR AND FRAME
FLOOR TO FLOOR EXPANSION
JOINT. BASIS OF DESIGN: C-S
GROUP GTRD-400, W/ FIRE BARRIER
1' - 6 5/8"4"
SLAB EXTENSION, SEE
STRUCTURAL DWGS
5/8" TYPE X GWB ON
EXISTING WALL (UL V497)
FIRESTOP ALL
PENETRATIONS
ALTER EXISTING WALL
TO ACHIEVE 1HR FIRE
RATING
EXTEND EXISTING 5/8"
TYPE X GWB TO SLAB
WALL EXPANSION
JOINT BEYOND
PARTITION WALL AS
SCHEDULED
CUT BACK EXISTING CFMF
AND PROVIDE NEW TOP
TRACK AT UNDERSIDE OF
NEW SLAB
EXISTING FLOORING TO
REMAIN
EXTEND NEW FLOOR
FINISH TO EXISTING
FLOOR FINISH AND
TERMINATE WITH DIVIDER
STRIP
/2
FILL WITH NON-SHRINK
GROUT AS REQUIRED
3 1/2"
11"
M4A
SCHEDULED CEILING.
SEE RCP
4" MIN.
4" CEILING EXPANSION JOINT.
BASIS OF DESIGN PRODUCT:
C-S GROUP MODEL FWSC-400
CFMF DOOR HEADER.
SEE TYP DOOR DETAILS
SCHEDULED DOOR
EXISTING PHASE 1
WALL ASSEMBLY
5/8" TYPE X GWB ON
EXISTING WALL (UL V497)
FIRESTOP ALL
PENETRATIONS - LEVEL
1 ONLY
ALTER EXISTING WALL
TO ACHIEVE 1HR FIRE
RATING - LEVEL 1 ONLY
M6B
4" WALL EXPANSION JOINT BEYOND
WOOD LOOK PHENOLIC
WALL PANEL SYSTEM
SIDING SYSTEM MOUNTING
CLIP &SYSTEM SPECIFIC
FASTENER, ATTACHED TO
PLYWOOD BACKER
4" WIDE 5/58" FIRE RATED
PLYWOOD (SPACE 20" O.C.),
PAINT BACKER BLACK TO
HIDE GAPS AT VERTICAL BUTT
JOINTS BETWEEN PLANKS
HOLD PLYWOOD BACK FROM
FACE OF FINISHED PANEL 1/4" -
PROVID J-BEAD TRIM TO CONCEAL
RAW EDGE OF PLYWOOD BACKER
PROVIDE 2-SIDED TAPE
TO SECURE TOP EDGE
OF PLANK WHERE CLIPS
CANNOT BE INSTALLED
ALUMINUM EDGE TRIM
PROVIDE 2-SIDED TAPE TO
SECURE BOTTOM EDGE OF
PLANK WHERE CLIPS CANNOT
BE INSTALLED
LEVEL 1
86' - 4"
12-1
1' - 6 5/8" VIF1"
4"
EXISTING PHASE 1
BUILDING ENVELOPE
EXISTING WALL SYSTEM TO
BE REMOVED BACK TO CMU
PARTITION WALL AS SCHEDULED
CONCRETE SLAB,
SEE STRUCTURAL
DWGS
PARTITION WALL AS
SCHEDULED
EXISTING AVB TO REMAIN
CONTINUOUS FIRESTOPPING.
SEE DETAIL
EXISTING 1HR RATED WALL
9"
/B4 GI003
SCHEDULED WALL
BASE
WOOD LOOK PHENOLIC WALL PANEL SYSTEM
SIDING SYSTEM MOUNTING CLIP &SYSTEM SPECIFIC
FASTENER, ATTACHED TO PLYWOOD BACKER
4" WIDE 5/58" FIRE RATED PLYWOOD (SPACE 20"
O.C.), PAINT BACKER BLACK TO HIDE GAPS AT
VERTICAL BUTT JOINTS BETWEEN PLANKS
ALUMINUM EDGE TRIM
PROVIDE 2-SIDED TAPE TO SECURE BOTTOM EDGE
OF PLANK WHERE CLIPS CANNOT BE INSTALLED
HOLD PLYWOOD BACK FROM FACE OF
FINISHED PANEL 1/4" - PROVID J-BEAD TRIM TO
CONCEAL RAW EDGE OF PLYWOOD BACKER
LEVEL B
73' - 0"
BASEMENT LEVEL
73' - 0"
EXISTING PHASE 1
BUILDING ENVELOPE
EXISTING DRAINAGE MAT AND
INSULATION REMOVED ABOVE NEW SLAB
2' - 2 5/8" VIF1"
PARTITION WALL AS SCHEDULED
1" RIGID INSULATION
CONCRETE SLAB, SEE
STRUCTURAL DWGS
VAPOR RETARDAR TO BE
CONTINUOUS UNDER SLAB
AND WRAP UP WALL
2" RIGID INSULATION TO BE
CONTINUOUS UNDER SLAB
SCHEDULED WALL BASE
WOOD LOOK PHENOLICWALL
PANEL SYSTEM
SIDING SYSTEM MOUNTING CLIP &SYSTEM
SPECIFIC FASTENER, ATTACHED TO
PLYWOOD BACKER
4" WIDE 5/58" FIRE RATED PLYWOOD
(SPACE 20" O.C.), PAINT BACKER BLACK TO
HIDE GAPS AT VERTICAL BUTT JOINTS
BETWEEN PLANKS
ALUMINUM EDGE TRIM
PROVIDE 2-SIDED TAPE TO SECURE
BOTTOM EDGE OF PLANK WHERE CLIPS
CANNOT BE INSTALLED
HOLD PLYWOOD BACK FROM FACE OF
FINISHED PANEL 1/4" - PROVID J-BEAD TRIM TO
CONCEAL RAW EDGE OF PLYWOOD BACKER
LEVEL 2
99' - 8"
12-1
EXISTING PHASE 1
BUILDING ENVELOPE
EXISTING WALL SYSTEM TO
BE REMOVED BACK TO CMU
CONCRETE SLAB,
SEE STRUCTURAL
DWGS
EXISTING AVB TO REMAIN
CONTINUOUS FIRESTOPPING.
SEE DETAIL
EXISTING 1HR RATED WALL
1' - 6 5/8" VIF4"
4"
PARTITION WALL AS
SCHEDULED
/C1 GI003
PARTITION WALL
AS SCHEDULED
SCHEDULED WALL
BASE
WOOD LOOK PHENOLIC WALL PANEL SYSTEM
SIDING SYSTEM MOUNTING CLIP &SYSTEM SPECIFIC
FASTENER, ATTACHED TO PLYWOOD BACKER
4" WIDE 5/58" FIRE RATED PLYWOOD (SPACE 20" O.C.),
PAINT BACKER BLACK TO HIDE GAPS AT VERTICAL
BUTT JOINTS BETWEEN PLANKS
ALUMINUM EDGE TRIM
PROVIDE 2-SIDED TAPE TO SECURE BOTTOM EDGE
OF PLANK WHERE CLIPS CANNOT BE INSTALLED
STEEL BEAM, SEE
STRUCTURAL
DWGS
HOLD PLYWOOD BACK FROM FACE OF
FINISHED PANEL 1/4" - PROVID J-BEAD TRIM TO
CONCEAL RAW EDGE OF PLYWOOD BACKER
LEVEL 1
86' - 4"
1' - 7 5/8" VIF3"
EXISTING PHASE 1
BUILDING ENVELOPE
EXISTING EXTERIOR WALL
SYSTEM TO BE REMOVED
BACK TO SHEATHING
PARTITION WALL AS SCHEDULED
CONCRETE SLAB, SEE
STRUCTURAL DWGS
CONTINUOUS FIRESTOPPING.
SEE DETAIL
EXISTING 1HR RATED
HOLLOW CORE SLAB
EXISTING PRECAST TO
REMAIN
PARTITION WALL AS
SCHEDULED
0"
1"
REINSTALL EXISTING
WALL BASE ON NEW
GWB WALL
5/8" TYPE X GWB ON
EXISTING WALL (UL
V497) FIRESTOP ALL
PENETRATIONS
ALTER EXISTING WALL
TO ACHIEVE 1HR FIRE
RATING
NEW CONCRETE STEM
WALL ON TOP OF
EXISTING STEM WALL.
CONNECT TO EXISTING
HOLLOW CORE SLAB.
SEE STRUCTURAL
DWGS
NEW SHEATHING TO
ALIGN WITH EXISTING
CUT EXISTING CFMF AT
1ST FLOOR SLAB AND
PROVIDE NEW BASE
TRACK
/B4 GI003
WOOD LOOK PHENOLIC
WALL PANEL SYSTEM
ALUMINUM EDGE TRIM
SIDING SYSTEM MOUNTING CLIP
& SYSTEM SPECIFIC FASTENER,
ATTACHED TO PLYWOOD BACKER
4" WIDE 5/58" FIRE RATED PLYWOOD
(SPACE 20" O.C.), PAINT BACKER BLACK TO
HIDE GAPS AT VERTICAL BUTT JOINTS
BETWEEN PLANKS
PROVIDE 2-SIDED TAPE TO SECURE
BOTTOM EDGE OF PLANK WHERE
CLIPS CANNOT BE INSTALLED
LEVEL 2
99' - 8"
1' - 6 5/8" VIF4"
EXISTING CONTINUOUS
FIRESTOPPING
EXISTING PHASE 1
BUILDING ENVELOPE
PARTITION WALL AS SCHEDULED
CONCRETE SLAB, SEE
STRUCTURAL DWGS
5/8" TYPE X GWB ON
EXISTING WALL (UL V497)
FIRESTOP ALL
PENETRATIONS
ALTER EXISTING WALL
TO ACHIEVE 1HR FIRE
RATING
PARTITION WALL AS
SCHEDULED
EXTEND EXISTING 5/8"
TYPE X GWB TO SLAB
CONTINUOUS
FIRESTOPPING. SEE
DETAIL
11 3/8"
/C1 GI003
WOOD LOOK PHENOLIC
WALL PANEL SYSTEM
ALUMINUM EDGE TRIM
4" WIDE 5/58" FIRE RATED PLYWOOD
(SPACE 20" O.C.), PAINT BACKER
BLACK TO HIDE GAPS AT VERTICAL
BUTT JOINTS BETWEEN PLANKS
PROVIDE 2-SIDED TAPE TO SECURE
BOTTOM EDGE OF PLANK WHERE
CLIPS CANNOT BE INSTALLED
SIDING SYSTEM MOUNTING CLIP &
SYSTEM SPECIFIC FASTENER,
ATTACHED TO PLYWOOD BACKER
HOLD PLYWOOD
BACK FROM FACE
OF FINISHED PANEL
1/4" - PROVID J-
BEAD TRIM TO
CONCEAL RAW
EDGE OF PLYWOOD
BACKER
WALL BASE AS
SCHEDULED
LEVEL 2
99' - 8"
2-F
METAL THROUGH-WALL
FLASHING W/ DRIP EDGE TO
EXTEND UP WALL 8" MIN.
COUNTER FLASH WITH AIR
BARRIER MEMBRANE, TYP .
RELIEVING ANGLE ATTACHED TO
SLAB EDGE BEHIND, SEE STRUCT.
DWGS. SEAL AVB AROUND
EXTERIOR WALL PENETRATION
MORTAR NET,
MIN 10" HIGH TYP.
WEEP
BRICK VENEER COURSING ,
TYP
SLAB EDGE SMOKE
STOP. SEE TYP.
FIRESTOPPING DETAILS
COMPOSITE
CONCRETE FLOOR,
SEE STRUCT. DWGS.
MASONRY ANCHOR
E1
LEVEL 1
86' - 4"
2-D
CEILING AS
SCHEDULED
SLOT DIFFUSER. SEE
MECH FOR MORE
INFORMATION
METAL COLUMN WRAP
STEEL COLUMN, SEE
STRUCT. DWGS.
CURTAIN WALL
SYSTEM AS
SCHEDULED
FASTEN BRACKET TO
STRUCTURE PER
MANUFACTURER
STANDARD DETAIL
BACKER ROD AND
SEALANT
TOPPING SLAB OVER
METAL DECK, SEE
STRUCT. DWGS.
CONTINUOUS
FIRESTOPPING,
SEE DETAIL
CONTINUOUS TRIM BY
CURTAIN WALL
MANUFACTURER, FINISH
TO MATCH CURTAIN WALL
BACKER ROD &
SEALANT
/C1 GI003
SCRIBE COLUMN WRAP
ENCLOSURE AROUND SILL,
WHERE PRESENT.
PROVIDE FINISH TRIM
AROUND SCRIBED EDGE
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD
WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH
PROJECT NORTH
/8
/2
:1
:3
A M
U A u to d e sk A u to sa ve s \R e vi t\
V
A M
C P
R O
V
ID
E N
C E
M H
C P
II
A R
C H
R b e n
.s to o d le yM
Q F
.r vt
AE512
650-347
NEW MENTAL HEALTH BUILDING -
PHASE 2
830 CHALKSTONE AVE PROVIDENCE, RI 02908
JRB BRS04 FEB 2022
100% CD SUBMISSIONSECTION DETAILS
FULLY SPRINKLEREDVA RI FACILITIES MANAGEMENT
SERVICE
1 1/2" = 1'-0"
F3 EXPANSION JOINT DETAIL @ LEVEL B DOOR SILL
1 1/2" = 1'-0"
F1 EXPANSION JOINT DETAIL @ LEVEL B DOOR HEAD
1 1/2" = 1'-0"
D3 EXPANSION JOINT DETAIL @ LEVEL 1 DOOR SILL
1 1/2" = 1'-0"
B3 EXPANSION JOINT DETAIL @ LEVEL 2 DOOR SILL
1 1/2" = 1'-0"
D1 EXPANSION JOINT DETAIL @ LEVEL 1 AND 2 DOOR HEAD
1 1/2" = 1'-0"
D8 EXPANSION JOINT DETAIL @ LEVEL 1 STAIR
1 1/2" = 1'-0"
F8 EXPANSION JOINT DETAIL @ LEVEL B STAIR
1 1/2" = 1'-0"
B8 EXPANSION JOINT DETAIL @ LEVEL 2 STAIR
1 1/2" = 1'-0"
D5 EXPANSION JOINT DETAIL @ LEVEL 1 CFMF
1 1/2" = 1'-0"
B5 EXPANSION JOINT DETAIL @ LEVEL 2 CFMF
1 1/2" = 1'-0"
B1 WALL SECTION @ BRICK FACADE RELIEVING ANGLE
1 1/2" = 1'-0"
F5 COLUMN WRAP TERMINATION AT CEILING & FLOOR
PRECAST PROFILE 'A' - COPING 'A'
SLOPE SILL FOR DRAINAGE
(MIN. 1/4":12")
/2
1' - 6 1/2"
V A
R R
IE
S
S
E E
E L E
V A
T
IO
N S
3 5/8"
PRECAST PROFILE 'B' - WALL BASE
PANEL AT CMU AND CURTAIN WALL
ANCHORS LOCATED AND
INSTALLED BY MANUFACTURER
ALL ANCHORAGE
DESIGN AND DETAILING
PART OF DELIGATED
DESIGN
V A
R
IE
S
1/2"
PROVIDE BACKER
ROD & SEALANT AT
PANEL JOINTS, TYP.
/4
3/4"
1/2"
VARIES
V A
R
IE
S
PRECAST COPING JOINTS TO
ALIGN W/ CMU COURSING, TYP.
CUT COPING AS REQUIRED TO
ALIGN COPING/WALL TYP.
TRANSITIONS,CORNER
CONDITIONS, ETC.
CENTER TO CENTER
6' - 0"
T Y
P
/2
5' - 11 1/2" TYP. PANEL
V A
R
IE
S
PRECAST COPING JOINTS TO
ALIGN W/ CMU COURSING, TYP.
CUT COPING AS REQUIRED TO
ALIGN COPING/WALL TYP.
TRANSITIONS,CORNER
CONDITIONS, ETC.
5' - 11 1/2" TYP. PANEL
CENTER TO CENTER
6' - 0"
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD
WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH
PROJECT NORTH
/8
/2
:1
:3
A M
U A u to d e sk A u to sa ve s \R e vi t\
V
A M
C P
R O
V
ID
E N
C E
M H
C P
II
A R
C H
R b e n
.s to o d le yM
Q F
.r vt
AE513
650-347
NEW MENTAL HEALTH BUILDING -
PHASE 2
830 CHALKSTONE AVE PROVIDENCE, RI 02908
JRB BRS04 FEB 2022
100% CD SUBMISSIONPRECAST PROFILES
FULLY SPRINKLEREDVA RI FACILITIES MANAGEMENT
SERVICE
3" = 1'-0"
F8 PRECAST PROFILES
6" = 1'-0"
B6 PRECAST PANEL JOINT
6" = 1'-0"
B4 TYPICAL PRECAST COPING AND BASE CORNER DETAIL - PLAN
DETAIL
1" = 1'-0"
D4 TYPICAL PRECAST COPING AND BASE SEGMENTS -
ELEVATION VIEW @ COPING
1" = 1'-0"
F4 TYPICAL PRECAST COPING AND BASE SEGMENTS -
ELEVATION VIEW @ CMU
CABINET/COUNTER GENERAL NOTES:
1. SEE FINISH SCHEDULE AND/OR INTERIOR
ELEVATIONS FOR CABINET/COUNTER CLADDING BY
ROOM.
2. PANEL CORE AND EDGE BANDING AS SPECIFIED OR
IMPLIED BY COUNTER GRADE. SPECIFICATION
LANGUAGE SUPERSEDES STANDARD.
3. FASTEN CABINETS AS REQUIRED BY STANDARD
FOR GRADE OF CABINET AS SPECIFIED.
4. PROVIDE LOCKS IN LOCATIONS AS INDICATED ON
INTERIOR ELEVATIONS AND/OR IN SPECIFICATION.
5. PROVIDE BACK AND END SPLASHES AT
COUNTERS WITH SINKS AND AS INDICATED ON
INTERIOR ELEVATIONS.
6. MATCH BACK AND END SPLASHES TO
COUNTERTOP MATERIAL UNLESS NOTED
OTHERWISE.
7. SCRIBE AND SEAL COUNTERS AND/OR SPLASHES
TO WALL.
8. COORDINATE CABINET ENCLOSURE WITH
PLUMBING DRAWINGS AND SPECIFICATIONS
PRIOR TO FABRICATION. NOTIFY ARCHITECT OF
DISCREPANCIES.
SPECIFIED CABINET STRETCHERS,
BLOCKING AND FASTENERS AS
REQUIRED BY CABINET GRADE (TYP.)
BACK AND END SPLASHES WHERE
INDICATED ON INTERIOR ELEVATION
SCHEDULED COUNTERTOP
FINISHED FLOOR
DUST PANEL, STRETCHERS AND STOP
SHELF
SCHEDULED WALL
DRAWER FRONT
DRAWER BOTTOM
DOOR PULL
CABINET BOTTOM
SCHEDULED BASE
2' - 1" U.N.O.
DRAWER SUB FRONT
DRAWER BACK AND SIDE
U .N
.O
CABINET BACK
4" 4"
1' - 9" CABINET END
ADJUSTABLE SHELF SUPPORT
ADJUSTABLE SHELF
REST2' - 0"
DOOR
STRETCHERS3 1/2"
DRAWER PULL
MIN.
1' - 9"
AE520
F10
Sim
SCHEDULED WALL
BACK AND END SPLASHES
WHERE INDICATED ON
INTERIOR ELEVATIONS
SCHEDULED COUNTER TOP
SPECIFIED CABINET
STRETCHERS, BLOCKING
AND FASTENERS AS
REQUIRED BY CABINET
GRADE, TYP.
CONCEALED
COUNTER BRACKETS,
ATTACH TO SIDE OF
STUD.
SCHEDULED BASE
FINISHED FLOOR
S E
E I N
T E
R
IO
R E
L E
V A
T
IO
N S
UNO
2' - 1"
GROMMET. SEE FINISH PLAN
FOR LOCATION.
4 1/2" AE520
F10
Sim
10"
U.N.O.
1' - 0"
2" 2"
U .N
.O
SCHEDULED WALL
CABINET TOP
BLOCKING AND FASTENERS AS
REQUIRED BY CABINET GRADE (TYP.)
DOOR
CABINET BACK
SHELF
ADJUSTABLE SHELF SUPPORT
ADJUSTABLE SHELF REST
CABINET END
DOOR PULL
CABINET BOTTOM
MILLWORK SOFFIT
CORNER BEAD
BACK AND END SPLASHES
WHERE INDICATED ON
INTERIOR ELEVATIONS
SCHEDULED COUNTERTOP
FULLY ENCLOSED APRON
PROVIDE CABINET STRETCHERS,
BLOCKING AND FASTENERS AS
REQUIRED BY CABINET GRADE (TYP.)
REMOVABLE ACCESS PANEL.
FASTEN TO BRACE W/ REMOVABLE
SATIN STAINLESS STEEL SCREWS.
M
IN
8" MIN.
M
IN
M
A X
SCHEDULED BASE
SCHEDULED SINK (DETAIL INTENDED
FOR 5 1/2" DEEP SINK WITH DRAIN AT
BACK AND TRAP ELBOW BEND TO BACK
OR SIDE.)
2' - 1" U.N.O.
FINISHED FLOOR6" MAX.
SCHEDULED WALL
NOTE:
DIMENSIONS GIVEN ARE
TO ILLUSTRATE
TOLERANCES REQUIRED
TO MEET ABA STANDARD.
CABINET END
AE520
F10
Sim
SCHEDULED WALL
BLOCKING AS
REQUIRED
SHELF
ADJUSTABLE SHELF
BRACKET
ADJUSTABLE SHELF
SUPPORT
SCHEDULED BASE
FINISHED FLOOR
1' - 6"
NOTE: AT ROOM 038
U.N.O.
1' - 0"
U .N
.O
SCHEDULED WALL
CABINET TOP
BLOCKING AND FASTENERS AS
REQUIRED BY CABINET GRADE
(TYP.)
DOOR
CABINET BACK
CABINET END, BEYOND
DOOR PULL
MICROWAVE SHELF
1' - 5"
CABINET BOTTOM
OUTLET BOX. SEE ELEC.
DWGS FOR MORE INFO
MILLWORK SOFFIT
CORNER BEAD
OPEN CABINET BACK
PLAN
N .T
.S
A F
F
NOTES:
1. VERIFY ACTUAL OPENING SIZE WITH MANUFACTURER
2. PROVIDE CONTINUOUS RATING FOR CABINETS IN RATED WALLS
SECTION
WALL TYPE AS SCHEDULED
WD BLOCKING
WD BLOCKING
RECESSED FIRE
EXTINGUISHER
CABINET
FIRE EXTINGUISHER
FINISH FLOOR
R
/8
/2
SOLID SURFACE
COUNTERTOP
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD
WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH
PROJECT NORTH
/8
/2
:1
:4
A M
U A u to d e sk A u to sa ve s \R e vi t\
V
A M
C P
R O
V
ID
E N
C E
M H
C P
II
A R
C H
R b e n
.s to o d le yM
Q F
.r vt
AE520
650-347
NEW MENTAL HEALTH BUILDING -
PHASE 2
830 CHALKSTONE AVE PROVIDENCE, RI 02908
JRB ARW04 FEB 2022
100% CD SUBMISSIONINTERIOR DETAILS
FULLY SPRINKLEREDVA RI FACILITIES MANAGEMENT
SERVICE
1 1/2" = 1'-0" AE206
F6 BASE CABINET W/ DRAWER
1 1/2" = 1'-0" AE205
D8 OPEN COUNTER SECTION CONCEALED BRACKETS
1 1/2" = 1'-0" AE110
B8 WALL CABINET SECTION
1 1/2" = 1'-0" AE206
F8 ACCESSIBLE SINK COUNTER AND APRON
1 1/2" = 1'-0"
F4 ADJUSTABLE WALL SHELVES
1 1/2" = 1'-0" AE206
B6 WALL CABINET SECTION w/ MICROWAVE SHELF
1 1/2" = 1'-0"
D6 FULLY RECESSED FIRE EXTIGUISHER CABINET
6" = 1'-0"
F10 COUNTER EDGE DETAILS
PUSH BUTTON LOCK
/2
WP-1 RUNS TO UNDERSIDE OF
TRANSACTION
2' - 1"
SSURF TRANSACTION
CONCEALED COUNTER
BRACKET
"FRAMELESS" PASS-THRU
WINDOW HARDWARE
ROLLER ASSEMBLY
SLIDING GLASS DOOR GUIDE
GWB OPENING BEYOND
3"
2 1/8"
LG-1
SEALANT
SCHEDULED WALL
WD BLOCKING
CORNER BEAD, TYP
GWB RETURN, TYP
SCHEDULED
COUNTER
WD BLOCKING
SCHEDULED WALL
SCHEDULED BASE
PT-2 TEXTURED TILE
SCRIBE TILES AROUND WATER
FOUNTAIN. SILICONE BEAD AROUND
WATER FOUNTAIN
SCHEDULED WALL
WATER FOUNTAIN
AS INDICATED
WINDOW AS SCHEDULED
CEILING AS SCHEDULED
GWB INFILL. ALIGN WITH ROUGH
OPENING OF WINDOW
MINERAL FIBER INSULATION
CFMF BOX BEAM AND FRAMING
1" SATIN ANODIZED EXTRUDED
ALUMINUM FINGER PULL. FULL
HEIGHT OF GLASS
PUSH LOCKSCHEDULED WALL
SSURF TRANSACTION
BEYOND
2' - 2"
PROVIDE A CLEAR SILICONE BEAD
AT EDGE OF FIXED PANEL
PROVIDE CLEAR PLASTIC BUMPERS
WHERE SLIDING PANEL WILL STOP
SLIDING DOOR GLIDE ATTACHED
TO TRANSACTION COUNTER
PROVIDE CLEAR PLASTIC BUMPERS
WHERE SLIDING PANEL WILL STOP
SCH. WALL
CORNER GUARD CAP.
ALIGN TOP EDGE OF WALL
PROTECTION WITH BOTTOM
OF CORNER GUARD TOP CAP
CORNER GUARD
SCHEDULED WALL
PROTECTION.
SCHEDULED WALL BASE
O
R
R
W C
U N
O
S E
E F
IN
IS
H S
C H
E D
U L E
C
O R
N E
R G
U A
R D
S W
H E
R E
N O
R W
C U
N O
BOTTOM OF CORNER
GUARD TO ALIGN W/ TOP
OF WALL BASE
3"
RETAINER SCREWED
INTO STUDS
RWC COVER TO MATCH
ADJACENT RWC WHERE
SCHEDULED
RETAINER
RWC TO RUN BEHIND
CORNER GUARD WHERE
SCHEDULED
WOOD BLOCKING
CEILING RECESSED PROJECTOR
SCREEN WHERE SHOWN ON RCP
SCHEDULED CEILING
ATTACHMENTS TO STRUCTURE
AS RECOMMENDED BY
MANUFACTURER, PROVIDED BY
CONTRACTOR
DUAL SHADE BRACKET & POCKET, TOP
MOUNTED
NOTE: SEE CURTAINWALL DETAILS FOR
TYPICAL CURTAIN WALL AND ROLLER
SHADE DETAIL: /- ---
CONTINUOUS BLOCKING HUNG FROM
COLD FORM METAL FRAMING. BLOCKING
MUST BE LEVEL
3" SHADE TRIM ENCLOSURE
OUTSIDE FACE OF GWB TO ALIGN W/
OUTSIDE FACE OF MULLION
STOREFRONT AS SCHEDULED
MIN
8 3/4"
TEAR AWAY J BEAD
CFMF BOX BEAM AND FRAMING
GWB ATTACHED W/
ATTACHMENT CLIP
SHADE TRIM ENCLOSURE CLIP BY
CEILING MANUFACTURER
DIFFUSER. SEE MECH. DWGS.
FOR MORE INFORMATION
SINGLE ROLLER
SHADE & POCKET,
TOP ATTACHED. SEE
FINISH PLANS FOR
LOCATIONS THAT
HAVE ROLLER
SHADES
CEILING AS SCHEDULED
STOREFRONT AS SCHEDULED
GWB INFILL, ALIGN
WITH WINDOW
MULLION.
CONTINUOUS BLOCKING
ATTACHED TO COLD FORM METAL
FRAMING. BLOCKING MUST BE
LEVEL
TEAR AWAY J BEAD
CFMF BOX BEAM AT FRAMING
GWB ATTACHEMENT
CLIP
METAL FRAMING BRACE 32"
O.C. TIE TO SLAB ABOVE
5/8" GYPSUM BOARD FASCIA TO
6" ABOVE FINISHED CEILING
SCHEDULED CEILING
METAL FRAMING
CONTINUOUS
METAL FRAMING
HEADER
CONTINUOUS METAL CORNER BEAD
5/8" GYPSUM BOARD SOFFIT
AS INDICATED
AS INDICATED
WALL TYPE AS SCHEUDLED
CEILING RECESSED
PROJECTOR SCREEN
CEILING AS SCHEDULED
ATTACHMENTS TO STRUCTURE
AS RECOMMENDED BY
MANUFACTURER, SUPPLIED BY
CONTRACTOR
ALTERNATE INSTALLATION
METHOD, ADDITIONAL BRACKETS
MAY BE REQUIRED
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD
WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH
PROJECT NORTH
/8
/2
:1
:5
A M
U A u to d e sk A u to sa ve s \R e vi t\
V
A M
C P
R O
V
ID
E N
C E
M H
C P
II
A R
C H
R b e n
.s to o d le yM
Q F
.r vt
AE521
650-347
NEW MENTAL HEALTH BUILDING -
PHASE 2
830 CHALKSTONE AVE PROVIDENCE, RI 02908
JRB ARW04 FEB 2022
100% CD SUBMISSIONINTERIOR DETAILS
FULLY SPRINKLEREDVA RI FACILITIES MANAGEMENT
SERVICE
1 1/2" = 1'-0" AE204
F9 RECEPTION SLIDING WINDOW SECTION
3" = 1'-0" AE206
C9 TILE SECTION @ WATER FOUNTAIN
1 1/2" = 1'-0"
D3 INTERIOR - WINDOW TO CEILING
1 1/2" = 1'-0" AE204
C5 SLIDING WINDOW PLAN DETAIL
1 1/2" = 1'-0"
B3 CORNER GUARD CONDITION AXONEMETRIC DETAIL
6" = 1'-0"
B5 CORNER GUARD CONDITION PLAN DETAIL
1 1/2" = 1'-0" AE206
F5 GROUP THERAPY SHADE POCKET SECTION DETAIL
1 1/2" = 1'-0" AE204
D5 TYPICAL SHADE POCKET DETAIL AT CEILING
3" = 1'-0"
C3 SOFFIT AND FASCIA SECTION
3" = 1'-0"
F3 CEILING RECESSED PROJECTOR SCREEN
ATTACH RUNNERS TO
FLOOR @ 24" O.C. AND
WITHIN 1" OF ENDS.
OUTLET BOX
CONTINUOUS
ACOUSTICAL SEALANT
EACH SIDE
SCHEDULED BASE
BASE CONDITION
PLAN CONDITION
ONE LAYER OF 5/8"
TYPE "X" GWB. ON
BOTH SIDES OF METAL
STUD @ 16" O.C. SEE
SCHEDULE FOR STUD
SIZES
MINERAL FIBER
INSULATION FRICTION
FIT FOR SOUND
DEADENING. FIT TO
FULL WIDTH OF CAVITY
COVER ALL SIDES OF ALL
TEL. & ELEC. OUTLETS WITH
1/4" THICK ACOUSTICAL
SEALANT BEFORE APPLYING
GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON
OPP. SIDES OF PARTITIONS.
HEAD CONDITION
WALL TYPE VA PARTITION # STUD SIZE
METAL STUD WALL STUD SIZE SCHEDULE
M2 09P22M2 2 1/2"
M6 09P62M6 6"
M4 09P42M4 3 5/8"
AE601
B6
Sim CEILING AS
SCHEDULED (SEE
CEILING PLANS FOR
LOCATION AND
HEIGHTS)
NOTE: MINIMUM SOUND TRANSMISSION CLASS RATING OF STC-49
M4B 09P42M4B 3 5/8"
RATING
1HR
UL DES U465
M6B 09P62M6B 6"
1HR
UL DES U465
AE601
B4
Sim AT 1HR WALLS
ATTACH RUNNERS TO FLOOR @
24" O.C. AND WITHIN 1" OF ENDS.
OUTLET BOX
CONTINUOUS
ACOUSTICAL
SEALANT
SCHEDULED FLOOR
SCHEDULED BASE
BASE CONDITION
PLAN CONDITION
ONE LAYER OF 5/8" TYPE
"X" GWB. ON ONE SIDE OF
METAL STUD @ 16" O.C.
SEE SCHEDULE FOR STUD
SIZES.
MINERAL FIBER INSULATION
FRICTION FIT FOR SOUND
DEADENING. SAME THICKNESS
AS WALL STUD.
COVER ALL SIDES OF ALL TEL. &
ELEC. OUTLETS WITH 1/4" THICK
ACOUSTICAL SEALANT BEFORE
APPLYING GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON OPP.
SIDES OF PARTITIONS.
HEAD CONDITION
WALL TYPE VA PARTITION # STUD SIZE
METAL STUD CHASE STUD SIZE SCHEDULE
M2A 09P22M2A 2 1/2"
M6A 09P62M6A 6"
M4A 09P42M4A 3 5/8"
AE601
B6
SimCEILING AS
SCHEDULED (SEE
CEILING PLANS FOR
LOCATION AND
HEIGHTS)
M1 09P12M1A 7/8" HAT
ATTACH DEFLECTION
TRACK TO STRUCTURE
AT 24" O.C. AND WITHIN
1" OF END. PROVIDE
3/4" DEFLECTION.
HEAD CONDITION
GWB PER
PARTITION TYPE
CONTINUOUS
ACOUSTICAL
JOINT SEALANT
ON BOTH SIDES
COPE GWB AROUND
BEAMS, DECKING,
BRIDGING, PIPING, ETC.
CONCRETE SLAB ON
METAL DECK, SEE
STRUCT. DWGS.
ONE LAYER OF 5/8" TYPE
"X" GWB. ON ONE SIDE
OF 7/8" METAL FURRING
@ 16" O.C. SEE
SCHEDULE FOR
FURRING SIZES.
CEILING AS
SCHEDULED SHOWN
SEE CEILING PLANS
FOR LOCATION AND
HEIGHTS
CEILING AS
SCHEDULED (SEE
CEILING PLANS FOR
LOCATION AND
HEIGHTS)
UNDERSIDE OF MTL.
DECK
/4
SLUSH CELLS 4"
DEEP MIN W/ GROUT
CONTINUOUS MINERAL WOOL
FIRESTOP INSULATION AND
FIREPROOF SEALANT
ELECTRICAL BOX
PLAN CONDITION
COVER ALL SIDES OF ALL
TEL. & ELEC. OUTLETS WITH
1/4" THICK ACOUSTICAL
SEALANT BEFORE APPLYING
GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON
OPP. SIDES OF PARTITIONS.SCHEDULED BASE
BASE CONDITION
HEAD CONDITION
ATTACH RUNNERS TO FLOOR @
24" O.C. AND WITHIN 1" OF ENDS.
CONTINUOUS
ACOUSTICAL SEALANT
SCHEDULED FLOOR
ONE LAYER OF 5/8"
TYPE "X" GWB. ON ONE
SIDE OF 3 5/8" METAL
STUD (6" METAL STUDS
AT FEC LOCATIONS) @
16" O.C.
MINERAL FIBER
INSULATION FRICTION FIT
FOR SOUND DEADENING.
SAME THICKNESS AS
WALL STUD.
AE601
B1
Sim
GYPSUM WALL
BOARD CEILING
SYSTEM, SEE SPEC.
FOR MORE
INFORMATION.
8" NOM CMU BLOCK
UL DESIGN: U906
SEE STRUCT. DWGS.
FOR ATTACHMENT
CEILING AS
SCHEDULED (SEE
CEILING PLANS FOR
LOCATION AND
HEIGHTS)
PORCELAIN TILE
BASE
BASE CONDITION
PLAN CONDITION
NEW PARTITION AS
SCHEDULED
5/8" CEMENTITIOUS
BACKER UNIT
NEW TILE FINISH,
REFER TO FINISH
SCHEDULE
CENTER OUTLETS IN TILE. COVER
ALL SIDES OF ALL TEL. & ELEC.
OUTLETS WITH 1/4" THICK
ACOUSTICAL SEALANT BEFORE
APPLYING GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON OPP.
SIDES OF PARTITIONS.
HEAD CONDITION
NOTE:
-MINIMUM SOUND TRANSMISSION CLASS RATING OF STC-49
-TYPICAL WALL TILE INSTALLATION DETAIL AT ALL
LOCATIONS WHERE WALL TILE IS SPECIFIED. SEE FINISH
SCHEDULE.
BOTTOM OF MTL. DECK
FLEXIBLE FIRESTOP
SEALANT
FIRE TRAK
5/8" TYPE "X" GWB
CUT TO FIT DECK
FLUTES
METAL STUD
HEAD CONDITION:
UL HW-D-0060
O V
E R
L A
P
UL DESIGN: U465 AT 1HR
PARTITIONS
COPE GWB AROUND
BEAMS, DECKING,
BRIDGING, PIPING, ETC.
UNDERSIDE OF
CONCRETE
PLANK
SLUSH CELLS
4" DEEP MIN
w/ GROUT
CONTINUOUS
ACOUSTICAL TAPE
AND SEALANT
UL DESIGN: U906
SEE STRUCTURAL
FOR ATTACHMENT
NOTE: CEILING ASSEMBLY TO BE SIMILAR TO APPROVED UL #P541 CEILING SYSTEM
TWO LAYERS OF 5/8" TYPE "X" GWB ON
7/8" HAT CHANNEL STUD @ 16" O.C.
CONTINOUS FIRE RATED SEALANT, TYP.
SCHEDULED PARTITION
DIRECT ATTACH HAT CHANNELS
TO ROOF STRUCTURE ABOVE AS
REQUIRED TO MEET SCHEDULED
CEILING HEIGHT
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD
WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH
PROJECT NORTH
/8
/2
:1
:5
A M
U A u to d e sk A u to sa ve s \R e vi t\
V
A M
C P
R O
V
ID
E N
C E
M H
C P
II
A R
C H
R b e n
.s to o d le yM
Q F
.r vt
AE601
650-347
NEW MENTAL HEALTH BUILDING -
PHASE 2
830 CHALKSTONE AVE PROVIDENCE, RI 02908
JRB BRS04 FEB 2022
100% CD SUBMISSIONPARTITION TYPES AND DETAILS
FULLY SPRINKLEREDVA RI FACILITIES MANAGEMENT
SERVICE
3" = 1'-0"
F8 METAL STUD PARTITIONS - SOUND AND 1HR RATED
3" = 1'-0"
D8 METAL STUD CHASES
3" = 1'-0"
B6 TYPICAL METAL STUD HEAD CONDITION - SOUND
3" = 1'-0"
F1 C3 - 8" NOM CMU WALL - 3 5/8" CFMF ONE SIDE - 7/8 FURING
ON OTHER SIDE - 1HR
3" = 1'-0"
B8 TOILET ROOM WALLS W/ PORCELAIN TILE
3" = 1'-0"
B4 1HR PARTITION HEAD DETAIL
3" = 1'-0"
B1 TYPICAL HEAD CONDITION - CMU
3" = 1'-0"
D5 GWB CEILING ASSEMBLY - 1 HR FIRE RATED STAIR
MASONRY ANCHOR
2 1/2" RIGID INSULATION
W/ TAPED SEAMS
BRICK VENEER
EXTERIOR SHEATHING
1 7/8" AIR SPACE
5/8" 6" 5/8" 2 1/2" 1 7/8" 3 5/8"
FOAMED IN PLACE
INSULATION, 1" MIN.
CONTINUOUS AIR
VAPOR BARRIER
5/8" TYPE X GWB
ON 6" METAL STUDS
X
NOTE: R-22 MIN. AVERAGE WALL INSULATION (R-12.5
CONTINUOUS) OR U-0.045 ASSEMBLY U-FACTOR
7/8" AT BRICK INSETS
INDICATED ON
EXTERIOR BUILDING
ELEVATIONS
MASONRY ANCHOR
2 1/2" RIGID INSULATION
W/ TAPED SEAMS
CMU VENEER
EXTERIOR SHEATHING
2" AIR SPACE
5/8" 6" 5/8" 2 1/2" 2" 3 5/8"
FOAMED IN PLACE
INSULATION, 1" MIN.
CONTINUOUS AIR
VAPOR BARRIER
5/8" TYPE X GWB ON 6"
METAL STUDS
X
NOTE: R-22 MIN. AVERAGE WALL INSULATION (R-12.5
CONTINUOUS) OR U-0.045 ASSEMBLY U-FACTOR
MASONRY ANCHOR
2 1/2" RIGID INSULATION
W/ TAPED SEAMS
BRICK VENEER
1 7/8" AIR SPACE
5/8" 7/8" 7 5/8" 2 1/2" 1 7/8" 3 5/8"
CONTINUOUS AIR
VAPOR BARRIER
5/8" TYPE X GWB ON
7/8" HAT CHANNEL
8" CMU
NOTE: R-22 MIN. AVERAGE WALL INSULATION (R-12.5
CONTINUOUS) OR U-0.045 ASSEMBLY U-FACTOR
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD
WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH
PROJECT NORTH
/8
/2
:1
:0
A M
U A u to d e sk A u to sa ve s \R e vi t\
V
A M
C P
R O
V
ID
E N
C E
M H
C P
II
A R
C H
R b e n
.s to o d le yM
Q F
.r vt
AE602
650-347
NEW MENTAL HEALTH BUILDING -
PHASE 2
830 CHALKSTONE AVE PROVIDENCE, RI 02908
JRB BRS04 FEB 2022
100% CD SUBMISSIONEXTERIOR WALL TYPES AND
DETAILS
FULLY SPRINKLEREDVA RI FACILITIES MANAGEMENT
SERVICE
3" = 1'-0"
E1 EXTERIOR WALL TYPE E1: BRICK ON CFM STUD - SECTION
3" = 1'-0"
E2 EXTERIOR WALL TYPE E2: CMU ON CFM STUD - SECTION
3" = 1'-0"
E4 EXTERIOR WALL TYPE E4: BRICK ON CMU - SECTION
NOTES: