BID DOCUMENTS
FULLY SPRINKLERED
BID DOCUMENTS SUBMISSION
1/16" = 1'-0"1 OVERALL ELECTRICAL SITE PLAN
1 EXISTING DISTRIBUTION PANEL DP.
INTERCEPT EXISTING UNDERGROUND TWO 3"C. AND EXTEND TO NEW COTTAGE
PANELBOARD AS SHOWN. ABANDON EXISTING UNUSED CONDUIT IN PLACE AND CAP. REFER
TO POWER RISER DIAGRAM FOR DETAILS.
TWO 3"C. STUBBED OUT AWAY FROM BUILDING AS SHOWN FOR FUTURE USE. STUB UP
CONDUITS 6" AFF IN DATA ROOM AND CAP AT BOTH ENDS.
TWO 3"C. TO PANEL C3M. REFER TO POWER RISER DIAGRAM FOR DETAILS.
PANEL C3M.
TWO 3"C. TO PANEL C4M. REFER TO POWER RISER DIAGRAM FOR DETAILS.
PANEL C4M.
EXISTING FEEDER CONDUIT(S) AND CABLES FOR BUILDING 25. CONTRACTOR TO FIELD
VERIFY EXACT LOCATION.
EXISTING MANHOLE.
EXISTING COMMUNICATION CONDUIT(S) AND CABLES FOR BUILDING 25. CONTRACTOR TO
FIELD VERIFY EXACT LOCATION.
CORE DRILL SIDE OF EXISTING MANHOLE AS REQUIRED TO INSTALL NEW CONDUITS INTO
MANHOLE. SEAL PENETRATIONS WATERTIGHT.
TWO 3"C. AND TWO 2"C. INSTALLED BELOW GRADE FROM EXISTING MANHOLE TO BUILDING 26
DATA ROOM AS SHOWN FOR COMMUNICATIONS CABLING. STUB UP CONDUITS 6" AFF IN DATA
ROOM AND PROVIDE FULL LENGTH PULL STRING.
TWO 3"C. AND TWO 2"C. INSTALLED BELOW GRADE FROM EXISTING MANHOLE TO BUILDING 27
DATA ROOM AS SHOWN FOR COMMUNICATIONS CABLING. STUB UP CONDUITS 6" AFF IN DATA
ROOM AND PROVIDE FULL LENGTH PULL STRING.
CONNECT ACCESS CONTROL SYSTEM TO GATE MONITORING SWITCH TO BE PROVIDED BY
OTHERS.
CONNECT ACCESS CONTROL SYSTEM TO ELECTRIC GATE LOCK TO BE PROVIDED BY
OTHERS.
CONNECT ACCESS CONTROL SYSTEM TO REQUEST TO EXIT SWITCH BUILT INTO GATE
HARDWARE TO BE PROVIDED BY OTHERS.
INSTALL NEW AMAG MODEL 853 CARD READER AND CONNECT TO ACCESS CONTROL
SYSTEM.
TWO 1"C. INSTALLED BELOW GRADE FROM EXISTING MANHOLE TO BUILDING 26 DATA ROOM
AS SHOWN FOR FIRE ALARM CABLING. STUB UP CONDUITS 6" AFF IN DATA ROOM AND
PROVIDE FULL LENGTH PULL STRING.
TWO 1"C. INSTALLED BELOW GRADE FROM EXISTING MANHOLE TO BUILDING 27 DATA ROOM
AS SHOWN FOR FIRE ALARM CABLING. STUB UP CONDUITS 6" AFF IN DATA ROOM AND
PROVIDE FULL LENGTH PULL STRING.
OVERALL ELECTRICAL
SITE PLAN
SCALE: 1/16" = 1'-0"
ES1.0
EXISTING
COMMUNITY
BUILDING #24
EXISTING COTTAGE
BUILDING #25
FUTURE COTTAGE
BUILDING #28
NEW COTTAGE
BUILDING #26
NEW COTTAGE
BUILDING #27
DATA
ELEC.
ELEC.
DATA
MH
DATA
ELEC.
JJ
J J
J
J
J J
J J
J
CR
CR17
CR
CR
CR
CR
BID DOCUMENTS SUBMISSION
26-E1.0 1/4" = 1'-0"1
POWER FLOOR PLAN -
COTTAGE BUILDING #26
26-E1.0.dwg
1 UNDERGROUND FEEDER CONDUIT AND CABLES. SEE POWER RISER DIAGRAM FOR
DETAILS.
PANEL C3M.
PANEL C3 (3-SECTION).
RECEPTACLE FOR TV. VERIFY EXACT MOUNTING LOCATION WITH ARCHITECT.
RECEPTACLE MOUNTED HIGH ON WALL FOR LIFT TRACK BATTERY CHARGER. VERIFY
EXACT MOUNTING LOCATION WITH EQUIPMENT INSTALLER.
20A 120VAC SIMPLEX RECEPTACLE MOUNTED AT STANDARD RECEPTACLE HEIGHT FOR
PATIENT BED. HOMERUN 2-12, 1-12G, 3/4"C.
DEDICATED RECEPTACLE FOR REFRIGERATOR MOUNTED AT STANDARD RECEPTACLE
HEIGHT. HOMERUN 2-12, 1-12G, 3/4"C.
DEDICATED RECEPTACLE FOR RECLINING BATHING SYSTEM MOUNTED AT STANDARD
RECEPTACLE HEIGHT. HOMERUN 2-12, 1-12G, 3/4"C.
DEDICATED RECEPTACLE FOR WASHING MACHINE. HOMERUN 2-12, 1-12G, 3/4"C.
30A 250V I PHASE 3-WIRE AND GROUND STRAIGHT BLADE NEMA 14-30R RECEPTACLE
FOR DRYER. PROVIDE MATCHING #10/3 AND GROUND CORD AND PLUG. HOMERUN 3-10,
1-10 GND, 3/4" C.
DEDICATED RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR. HOMERUN 2-12,
1-12G, 3/4"C. REFER TO ARCHITECTURAL FOR DETAILS.
DEDICATED RECEPTACLE FOR COUNTERTOP PRINTER. HOMERUN 2-12, 1-12G, 3/4"C.
REFER TO ARCHITECTURAL FOR DETAILS.
INSTALL PUSHBUTTON STATION FOR MOTOR OPERATED OVERHEAD DOOR PROVIDED
WITH DOOR. COORDINATE DETAILS WITH EQUIPMENT PROVIDED.
CONNECT TO MOTOR OPERATED OVERHEAD DOOR. HOMERUN 2-12, 1-12G, 3/4"C.
COORDINATE DETAILS WITH EQUIPMENT PROVIDED.
CONNECT TO ELECTRIC FIREPLACE. HOMERUN 2-12, 1-12G, 3/4"C. COORDINATE
DETAILS WITH EQUIPMENT PROVIDED.
INSTALL A NEMA 6-20 1Ø 250V RECEPTACLE BELOW COUNTER FOR HOT WELLS. REFER
TO ARCHITECTURAL FOR EXACT MOUNTING LOCATION. PROVIDE MATCHING CORD AND
PLUG IF NECESSARY. CONTRACTOR TO VERIFY. HOMERUN 2-12, 1-12G, 3/4"C.
INSTALL A NEMA 5-20 1Ø 120V RECEPTACLE BELOW COUNTER FOR DRINK DISPENSER.
REFER TO ARCHITECTURAL FOR EXACT MOUNTING LOCATION. PROVIDE MATCHING
CORD AND PLUG IF NECESSARY. CONTRACTOR TO VERIFY. HOMERUN 2-12, 1-12G,
3/4"C.
CONNECT TO BUILT IN OVEN. HOMERUN 3-8, 1-10G, 1"C. VERIFY DETAILS AND
REQUIREMENTS WITH EQUIPMENT PROVIDED.
DEDICATED RECEPTACLE FOR LOCATED ABOVE COUNTER FOR MICROWAVE.
HOMERUN 2-12, 1-12G, 3/4"C. REFER TO ARCHITECTURAL FOR DETAILS.
CONNECT TO COOKTOP. HOMERUN 3-8, 1-10G, 1"C. VERIFY DETAILS AND
REQUIREMENTS WITH EQUIPMENT PROVIDED.
CONNECT TO RANGE HOOD. HOMERUN 2-12, 1-12G, 3/4"C. VERIFY DETAILS AND
REQUIREMENTS WITH EQUIPMENT PROVIDED.
DEDICATED RECEPTACLE FOR REFRIGERATOR MOUNTED AT 48 IN. AFF. HOMERUN
2-12, 1-12G, 3/4"C.
CONNECT TO AUTOMATIC DOOR OPENER. COORDINATE DETAILS AND REQUIREMENTS
WITH EQUIPMENT INSTALLER.
DEDICATED RECEPTACLE LOCATED BELOW COUNTER FOR GARBAGE DISPOSER.
HOMERUN 2-12, 1-12G, 3/4"C. INSTALL SWITCH ABOVE COUNTER TO CONTROL
RECEPTACLE. REFER TO ARCHITECTURAL FOR DETAILS.
DEDICATED RECEPTACLE LOCATED BELOW COUNTER FOR DISHWASHER. HOMERUN
2-12, 1-12G, 3/4"C. REFER TO ARCHITECTURAL FOR DETAILS.
FLUSH FLOOR BOX, 3 COMPARTMENT (WIREMOLD 880CS-3 OR EQUAL). ONE
COMPARTMENT WITH A DUPLEX RECEPTACLE, ONE COMPARTMENT FOR FUTURE
DATA/VOICE JACKS AND ONE COMPARTMENT WITH BLANK COVER. PROVIDE FLUSH
BRASS CARPET AND TILE FLANGE (WIREMOLD 837B OR EQUAL), FLIP-TOP DUPLEX
RECEPTACLE COVER PLATE (WIREMOLD 828R OR EQUAL), COMMUNICATIONS COVER
PLATE (WIREMOLD 828COMTC OR EQUAL) AND COMMUNICATIONS COVER PLATE
(829CK-3/4 OR EQUAL). VERIFY EXACT LOCATION WITH THE ARCHITECT. HOMERUN 2-12,
1-12G, 3/4"C. BELOW SLAB TO WALL AS SHOWN, THEN UP IN WALL TO ACCESSIBLE
CEILING SPACE, THEN TO PANEL. INSTALL ONE 1"C. BELOW SLAB FROM
COMMUNICATIONS COMPARTMENT TO WALL AS SHOWN, THEN UP TO ACCESSIBLE
CEILING SPACE FOR FUTURE DATA CABLING AND ONE 1-1/4"C. BELOW SLAB FROM
SPARE COMPARTMENT TO WALL AS SHOWN, THEN UP TO ACCESSIBLE CEILING SPACE.
PROVIDE FULL LENGTH PULL STRING IN SPARE 1-1/4"C.
FLUSH FLOOR BOX, 3 COMPARTMENT (WIREMOLD 880CS-3 OR EQUAL). ONE
COMPARTMENT WITH A DUPLEX RECEPTACLE, ONE COMPARTMENT FOR FUTURE
DATA/VOICE JACKS AND ONE COMPARTMENT WITH BLANK COVER. PROVIDE FLUSH
BRASS CARPET AND TILE FLANGE (WIREMOLD 837B OR EQUAL), FLIP-TOP DUPLEX
RECEPTACLE COVER PLATE (WIREMOLD 828R OR EQUAL), COMMUNICATIONS COVER
PLATE (WIREMOLD 828COMTC OR EQUAL) AND COMMUNICATIONS COVER PLATE
(829CK-3/4 OR EQUAL). VERIFY EXACT LOCATION WITH THE ARCHITECT. ROUTE 2-12,
1-12G, 3/4"C. BELOW SLAB TO NEXT FLOOR BOX AS SHOWN. INSTALL ONE 1"C. BELOW
SLAB FROM COMMUNICATIONS COMPARTMENT TO NEXT FLOOR BOX AS SHOWN FOR
FUTURE DATA CABLING AND ONE 1-1/4"C. BELOW SLAB FROM SPARE COMPARTMENT
TO NEXT FLOOR BOX AS SHOWN.
BUILDING
N.I.C.
N.I.C.
N.I.C.
BUILDING
NO SCALE
KEYPLAN
COTTAGE BLDG. 26 -
POWER FLOOR PLAN
SCALE: 1/4" = 1'-0"
D
B
G
H E A
C
F
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
J
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
GFI
GFI
H
GFI
GFI
AC
GFI
+48
GFI
GFI
GFI
GFI
GFI
AC
+48
J
BC BC
BC
BC
AC
J
BCBC
BC
BC
BC
BC
GFI
GFI
GFI
GFI
GFI
C3-1
C3-3
(ON)
C3-5
(ON)
C3-5
(ON)
C3-3
(ON)
C3-7
C3-15
C3-11
(ON)
C3-13
(ON)
C3-13
(ON)
C3-11
(ON)
C3-9
C3-31
C3-27
(ON)
C3-29
(ON)
C3-29
(ON)
C3-27
(ON)
C3-25
C3-17
C3-19
(ON)
C3-21
(ON)
C3-21
(ON)
C3-19
(ON)
C3-23
C3-33
6 C3-35
(ON)
C3-37
(ON)
C3-39
C3-35
(ON)
C3-37
(ON)
C3-2
C3-6,8
C3-4
C3-20
C3-12
7C3-14
C3-10
C3-18
H
WP
GFI
C3-168
C3-22
C3-24
C3-28
C3-26
C3-30
C3-36
(ON)
C3-36
(ON)
C3-36
(ON)
C3-40,42
C3-44,46
C3-48
J
J C3-54,56
C3-53
C3-55
C3-50
C3-57
C3-58,60
C3-52
C3-59
C3-61
C3-62 C3-64
26 27
C3-34
C3-38
C3 -4
C3-51 C3-49
C3-45
C3-43
C3-41
(ON)
C3-41
(ON)
C3-41
(ON)
C3-41
(ON)
C3-41
(ON)
C3-32
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
23RESIDENT
ROOM
TOIL.
TOIL.
TOIL.
CLEAN
SOILED
CORR.
TOIL.
RESIDENT
ROOM
SOILED
UTIL.
SPA/BATH/SAFE
ROOM
SAFE
ROOM
LAUNDRY/
CORR.
RESIDENT
ROOM
31TOIL.
30LAUNDRY
H.A.C.
CORR.
MEDS
GUEST
TOIL.
CORR.
CLEAN
TOIL.
RESIDENT
ROOM
1RESIDENT
ROOM
TOIL.
4TOIL.
SOILED
RESIDENT
ROOM
RESIDENT
ROOM
TOIL.
STAFF
OFFICE
FOYER
RECEIVING/STORAGE
CORR.
PANTRY
LIVING
ROOM
KITCHEN
MECHANICAL
STORAGE
19B
DATA
ELEC.
17 DINING
ROOM
TOIL.
AC
GFI
C3-70
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
BC
J
C3-72
(ON)
J
C3-72
(ON)
J
C3-74
(ON)
SUPPLIES/EQUIP.
STOR.
STORAGE
18A
STORAGE
11A
GFI GFI
GFI
GFIGFI
+48
+48
+48
+48
+48
+48
C3-78
BID DOCUMENTS SUBMISSION
26-E2.0 1/4" = 1'-0"1
EQUIPMENT POWER FLOOR PLAN -
COTTAGE BUILDING #26
26-E2.0.dwg
1. REFER TO SHEET 26-E8.1 FOR MECHANICAL EQUIPMENT CONNECTION CHART.
PANEL C3M.
CONNECT TO AIR HANDLER UNIT SUPPLY FANS VFD. REFER TO MECHANICAL
EQUIPMENT CONNECTION CHART FOR DETAILS.
CONNECT TO CONDENSING UNIT. REFER TO MECHANICAL EQUIPMENT CONNECTION
CHART FOR DETAILS.
CONNECT TO FAN COIL UNIT. REFER TO MECHANICAL EQUIPMENT CONNECTION CHART
FOR DETAILS.
2-12, 1-12G, 3/4"C. TO FAN COIL UNIT THROUGH MAPA PEDESTAL.
2-12, 1-12G, 3/4"C. TO CONDENSING UNIT THROUGH MAPA PEDESTAL.
CONNECT TO RECEPTACLE PROVIDED WITH PEDESTAL. REFER TO CORRESPONDING
CONDENSING UNIT IN MECHANICAL EQUIPMENT CONNECTION CHART FOR DETAILS.
CONNECT TO BOILER. REFER TO MECHANICAL EQUIPMENT CONNECTION CHART FOR
DETAILS.
CONNECT TO BOILER PUMP. REFER TO MECHANICAL EQUIPMENT CONNECTION CHART
FOR DETAILS. INTERLOCK PUMP WITH "BOILER PUMP" RELAY IN BOILER 26-1.
COORDINATE DETAILS WITH EQUIPMENT PROVIDED.
CONNECT TO BOILER PUMP. REFER TO MECHANICAL EQUIPMENT CONNECTION CHART
FOR DETAILS. INTERLOCK PUMP WITH "BOILER PUMP" RELAY IN BOILER 26-2.
COORDINATE DETAILS WITH EQUIPMENT PROVIDED.
CONNECT TO HEATING WATER PUMP. REFER TO MECHANICAL EQUIPMENT
CONNECTION CHART FOR DETAILS. PROVIDE AND INSTALL A 120VAC 30A RELAY WITH A
24VAC COIL AT PUMP TO ALLOW FOR PUMP CONTROL VIA EMS SYSTEM. COORDINATE
DETAILS WITH THE CONTROLS CONTRACTOR.
CONNECT TO UNIT HEATER. REFER TO MECHANICAL EQUIPMENT CONNECTION CHART
FOR DETAILS.
CONNECT TO EXHAUST FAN. REFER TO MECHANICAL EQUIPMENT CONNECTION CHART
FOR DETAILS. PROVIDE AND INSTALL A 120VAC 20A RELAY WITH A 120VAC COIL AT FAN
TO ALLOW FOR FAN CONTROL VIA EMS SYSTEM. COORDINATE DETAILS WITH THE
CONTROLS CONTRACTOR.
CONNECT TO EXHAUST FAN. REFER TO MECHANICAL EQUIPMENT CONNECTION CHART
FOR DETAILS.
DEDICATED RECEPTACLE FOR WATER HEATER. REFER TO MECHANICAL EQUIPMENT
CONNECTION CHART FOR DETAILS.
CONNECT TO CIRCULATION PUMP. REFER TO MECHANICAL EQUIPMENT CONNECTION
CHART FOR DETAILS.
CONNECT TO WATER SOFTENER. REFER TO MECHANICAL EQUIPMENT CONNECTION
CHART FOR DETAILS.
DEDICATED RECEPTACLE FOR MIOX MAIN CONTROLLER. COORDINATE EXACT
MOUNTING LOCATION WITH EQUIPMENT PROVIDED. HOMERUN 2-12, 1-12G, 3/4"C.
DEDICATED RECEPTACLE FOR MIOX OXIDANT TANK LEVEL SENSOR. COORDINATE
EXACT MOUNTING LOCATION WITH EQUIPMENT PROVIDED. HOMERUN 2-12, 1-12G,
3/4"C.
DEDICATED RECEPTACLE FOR REVERSE OSMOSIS SKID. COORDINATE EXACT
MOUNTING LOCATION WITH EQUIPMENT PROVIDED. HOMERUN 2-12, 1-12G, 3/4"C.
DEDICATED RECEPTACLE FOR EMS CONTROL PANEL. COORDINATE EXACT MOUNTING
LOCATION WITH EQUIPMENT PROVIDED. HOMERUN 2-12, 1-12G, 3/4"C.
BUILDING
N.I.C.
N.I.C.
N.I.C.
BUILDING
NO SCALE
KEYPLAN
COTTAGE BLDG. 26 -
EQUIPMENT POWER
FLOOR PLAN
SCALE: 1/4" = 1'-0"
D
B
G
H E A
C
F
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
23RESIDENT
ROOM
TOIL.
TOIL.
TOIL.
CLEAN
SOILED
CORR.
TOIL.
RESIDENT
ROOM
SOILED
UTIL.
SPA/BATH/SAFE
ROOM
39 SAFE
ROOM
LAUNDRY/
CORR.
RESIDENT
ROOM
TOIL.
LAUNDRY
H.A.C.
CORR.
45MEDS
GUEST
TOIL.
CORR.
CLEAN
42 TOIL.
RESIDENT
ROOM
1RESIDENT
ROOM
TOIL.
TOIL.
SOILED
RESIDENT
ROOM
RESIDENT
ROOM
TOIL.
STAFF
OFFICE
FOYER
RECEIVING/STORAGE
CORR.
PANTRY
LIVING
ROOM
KITCHEN
MECHANICAL
STOR.
19B
DATA
ELEC.
17 DINING
ROOM
TOIL.
AHU 26-1
CEF 26-10
CEF 26-4
CEF 26-7
CEF 26-8 CEF 26-9
CEF 26-3CEF 26-2
CEF 26-1
CEF 26-5
CEF 26-6
EF 26-2
EF 26-1
S
HW
P
-1
HW
P
-2
BOILER 26-2
BOILER 26-1
UH-26-1
CU 26-1
CU 26-2
MIOX 26-1WS 26-1 WH 26-1
J
C3M-1,3,5
JC3M-13,15,17
JC3M-19,21,23
FC 26-A
J J J
CU 26-A
J
C3M-2,4C3M-29
J
J
C3M-6
C3M-8 J C3M-10
BP 26-1
J C3M-12
BP 26-2
JJ
C3M-14
C3M-16 11 11
J C3M-18
JR
C3M-20
JR
C3M-22
J
C3M-24
J
C3M-26
J
C3M-28 J
C3M-30
JC3M-32
JC3M-34
J
C3M-42JC3M-36
J
C3M-40
J
C3M-38
GFIGFIGFI
C3 M-
C3
M-
C3 M-
JC3M-46
16CP 26-1
J C3M-31
GFI
C3M-48
SUPPLIES/EQUIP.
STOR.
STORAGE
18A
STORAGE
11A
S
S
S
S
S S
S
S
S
S
S
SS
S
S
C3M-33
BID DOCUMENTS SUBMISSION
26-E3.0 1/4" = 1'-0"1
LIGHTING FLOOR PLAN -
COTTAGE BUILDING #26
26-E3.0.dwg
1 CONNECT EMERGENCY DRIVER OF THE FIXTURE TO THE UNSWITCHED HOT
CONDUCTOR OF THE CIRCUIT. FIXTURE SHALL BE SWITCHED AND EMERGENCY
DRIVER SHALL ONLY BE ACTIVE IF CIRCUIT IS DE-ENERGIZED.
CHAIN HUNG FIXTURE(S) MOUNTED 9'-0" AFF.
MOUNT FIXTURE ON WALL ABOVE DOOR.
MOUNT FIXTURE ON WALL ABOVE MIRROR.
PANEL C3 (3-SECTION).
LIGHTING CONTROL PANEL LCP.
HOMERUN THROUGH LIGHTING CONTROL PANEL LCP.
MOUNT FIXTURE ON WALL APPROX. 8'-0" AFF. VERIFY EXACT MOUNTING LOCATION
WITH ARCHITECTURAL.
EGRESS FIXTURE ONLY AND EMERGENCY DRIVER SHALL ONLY BE ACTIVE IF CIRCUIT IS
DE-ENERGIZED.
PROVIDE A TWO BUTTON SWITCH STATION FOR THE LIGHTING CONTROL SYSTEM
EQUAL TO A HUBBELL LVSM1NP (WHITE COLOR) FOR LOCAL CONTROL OF
DINING/KITCHEN/LIVING/CORRIDOR/FOYER LIGHTS. TOP BUTTON SHALL CONTROL THE
DINING/KITCHEN/LIVING LIGHTS AND THE BOTTOM BUTTON SHALL CONTROL THE
CORRIDOR/FOYER LIGHTS.
PROVIDE A TWO BUTTON SWITCH STATION FOR THE LIGHTING CONTROL SYSTEM
EQUAL TO A HUBBELL LVSM2NP (WHITE COLOR) FOR LOCAL CONTROL OF CORRIDOR
LIGHTS. TOP BUTTON SHALL CONTROL THE DOWNLIGHTS AND THE BOTTOM BUTTON
SHALL CONTROL THE WALL SCONCES.
REFER TO ARCHITECTURAL ELEVATIONS FOR MOUNTING LOCATION.
SUSPEND FIXTURE(S) APPROX. 11'-0" AFF. REFER TO ARCHITECTURAL FOR DETAILS.
SUSPEND FIXTURE(S) APPROX. 7'-0" AFF. REFER TO ARCHITECTURAL FOR DETAILS.
COORDINATE FIXTURE LOCATION WITH BED/FURNITURE PLACEMENT PRIOR TO
INSTALLATION. REFER TO ARCHITECTURAL FOR DETAILS.
BUILDING
N.I.C.
N.I.C.
N.I.C.
BUILDING
NO SCALE
KEYPLAN
COTTAGE BLDG. 26 -
LIGHTING FLOOR PLAN
SCALE: 1/4" = 1'-0"
D
B
G
H E A
C
F
B B
BB
B
R R
P
M
BB
B B
B M
R
R
P
S S
Q Q
AEAAEAA
AE
A
AE
A
AE
A A AE A AE
A
AE
A
AE
AE
B B
B B B
M P
R
R
A
F E
EE
C
C
E
E
JJJ
K
K
L
L
JJJ
S E
E
E
E
E
E
E
E
E
E
L
J
J
GE
G
G GE
GE
D
DD
D
AE
AA
TTT
T
U
U
U
U
U
N
N
N
NN
N
N
N
V
V
V
V
V
V
V
V
V
V
V
V
VV
VV
VV
VV
H
Q
GE
G GE
PI
PI PI
PI
PI
PI
PI
DT
PI
PI
PI
PI
PI
PI
PI
XY
XY
XY
XY
X
X X
X X
X
X
X
1 2
1 2
C3-65
(ON)
C3-65
(ON)
C3-81
(ON)
C3-79
(ON)
C3-65
(ON)
C3-69
(ON)71
C3-69
(ON)
C3-81
(ON)
LC3-79
(ON)
C3-67
(ON)
C3-79
(ON)
C3-79
(ON)
C3-67
(ON)
C3-79
(ON)
C3-79
(ON)
1 1 1 C3-73
(ON)
C3-79
(ON)
1 1 1
1 1
C3-75
(ON)
C3-81
(ON)
C3-79
(ON)
8 9
L
X C3-79
(ON)
8 9
C3-81
(ON)
C3-81
(ON)
C3-79
(ON)
DT
C3-75
(ON)
B B
BB
B M
R
R
P
S
DT
C3-75
(ON)
BB
B B
B
R R
P
M
S
DT
C3-75
(ON)
DT
C3-71
(ON)
B B
B B B
M P
R
R
S
DT
C3-73
(ON)
B B
BB
B
R R
P
M
BB
B B
B M
R
R
P
S S
DT
C3-77
(ON)
DT
C3-77
(ON)
B B
BB
B M
R
R
P
S
DT
C3-77
(ON)
BB
B B
B
R R
P
M
S
DT
C3-77
(ON)
C3-79
(ON)
L10
L10
L10
L
L 11
L
11 L
L
C3-73
(ON)
C3-69
(ON)
WW
WWW
WW
121212
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
23RESIDENT
ROOM
TOIL.
TOIL.
24TOIL.
CLEAN
SOILED
CORR.
TOIL.
28 RESIDENT
ROOM
SOILED
UTIL.
SPA/BATH/
SAFE
ROOM
SAFE
ROOM
LAUNDRY/
CORR.
RESIDENT
ROOM
TOIL.
LAUNDRY
H.A.C.
CORR.
MEDS
GUEST
TOIL.
CORR.
CLEAN
TOIL.
RESIDENT
ROOM
RESIDENT
ROOM
TOIL.
4TOIL.
SOILED
RESIDENT
ROOM
RESIDENT
ROOM
TOIL.
STAFF
OFFICE
FOYER
RECEIVING/
STORAGE
CORR.
PANTRY
LIVING
ROOM
KITCHEN
MECHANICAL
STORAGE
19B
DATA
ELEC.
DINING
ROOM
TOIL.
F
CE
C
PI
C3-71
(ON)
C3-69
(ON)
Z
Z
SUPPLIES/
EQUIP.
STOR.
STORAGE
18A
PI
STORAGE
11A
13131313
131313
15 15
BID DOCUMENTS SUBMISSION
26-E4.0 1/4" = 1'-0"1
TELECOM FLOOR PLAN -
COTTAGE BUILDING #26
26-E4.0.dwg
1 84" DATA RACK. REFER TO DATA/VOICE/TV RISER DIAGRAM FOR DETAILS.
6' TALL PLYWOOD TERMINAL BOARD MOUNTED ON WALL AS SHOWN FOR VOICE/TV
EQUIPMENT. MOUNT SO THAT BOTTOM OF BOARD IS 18" AFF.
12" LONG X 2"H X 1/4" THICK COPPER SYSTEM GROUND BAR. MOUNT TO WALL W/
INSULATED FEET. ALL TERMINATIONS ON BAR WITH COMPRESSION CONNECTORS.
INSTALL TWO RJ-45 DATA JACKS IN ONE COMPARTMENT OF FLOOR BOX. REFER TO
POWER FLOOR PLAN FOR DETAILS.
TWO 3" EMT CONDUITS THROUGH INACCESSIBLE CEILING SPACE FOR
DATA/TELEPHONE CABLING BETWEEN DATA ROOM AND ACCESSIBLE CEILING SPACE
AS SHOWN. PROVIDE A FULL LENGTH PULL STRING. PROVIDE INSULATING BUSHINGS
ON EACH END OF CONDUIT.
INSTALL DOORBELL EQUAL TO A NUTONE LA11BG HIGH ON WALL. VERIFY EXACT
MOUNTING HEIGHT WITH ARCHITECT. INSTALL TRANSFORMER EQUAL TO A NUTONE
C915 ABOVE STAFF OFFICE ACCESSIBLE CEILING ABOVE DOORBELL IN A STANDARD
DOUBLE GANG JUNCTION BOX AND CONNECT TO DOORBELL AS NECESSARY.
HOMERUN 2-12, 1-12G, 3/4"C. TO CIRCUIT AS INDICATED.
INSTALL WATERWOOD WW162 DOORBELL PUSHBUTTON AND CONNECT TO DOORBELL.
INSTALL NEW ACCESS CONTROL EQUIPMENT. SYSTEM SHALL BE ABLE TO CONTROL 13
DOORS. INSTALL ONE DATA LINE TO ALLOW FOR CONNECTION TO NETWORK.
CONNECT ACCESS CONTROL SYSTEM TO DOOR MONITORING SWITCH TO BE PROVIDED
BY OTHERS.
CONNECT ACCESS CONTROL SYSTEM TO ELECTRIC DOOR LOCK TO BE PROVIDED BY
OTHERS.
CONNECT ACCESS CONTROL SYSTEM TO REQUEST TO EXIT SWITCH BUILT INTO DOOR
HARDWARE TO BE PROVIDED BY OTHERS.
INSTALL NEW AMAG MODEL 853 CARD READER AND CONNECT TO ACCESS CONTROL
SYSTEM.
BUILDING
N.I.C.
N.I.C.
N.I.C.
BUILDING
NO SCALE
KEYPLAN
COTTAGE BLDG. 26 -
TELECOM FLOOR PLAN
SCALE: 1/4" = 1'-0"
D
B
G
H E A
C
F
BC
TV
BC
TV
BC
BC
BC
W
W
W
W
4 4
D
W
W
W
W
TV
D
TV
D
TV
D
TV
TV
D
D
DD
DD
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
23RESIDENT
ROOM
TOIL.
TOIL.
TOIL.
CLEAN
SOILED
CORR.
TOIL.
RESIDENT
ROOM
SOILED
UTIL.
SPA/BATH/SAFE
ROOM
SAFE
ROOM
LAUNDRY/
CORR.
RESIDENT
ROOM
TOIL.
30LAUNDRY
H.A.C.
CORR.
MEDS
GUEST
TOIL.
CORR.
CLEAN
TOIL.
RESIDENT
ROOM
1RESIDENT
ROOM
TOIL.
4TOIL.
SOILED
RESIDENT
ROOM
RESIDENT
ROOM
TOIL.
STAFF
OFFICE
FOYER
RECEIVING/STORAGE
CORR.
PANTRY
LIVING
ROOM
KITCHEN
MECHANICAL
STORAGE
19B
DATA
ELEC.
17 DINING
ROOM
TOIL.
W
WA
WA
WA
WA
WA
WA
WA
WA
WA
WA
WA
WA
WAWA
W
W
DB
B
DB
DB7
DB
DB
SUPPLIES/EQUIP.
STOR.
STORAGE
18A
STORAGE
11A
C3-76
J
J
J
CR
CR
J
JJJ J
J
JJJ J
11 11 CR
J
J
J
J
J
CR
J
J
J
J
J
CR
BID DOCUMENTS SUBMISSION
26-E5.0 1/4" = 1'-0"1
NURSE CALL FLOOR PLAN -
COTTAGE BUILDING #26
26-E5.0.dwg
1 NURSE CALL MASTER STATION.
INSTALL NEW NURSE CALL CENTRAL EQUIPMENT. NEW EQUIPMENT SHALL BE 100%
COMPATIBLE WITH EXISTING HILL-ROM NURSE CALL SYSTEM.
BUILDING
N.I.C.
N.I.C.
N.I.C.
BUILDING
NO SCALE
KEYPLAN
COTTAGE BLDG. 26 -
NURSE CALL FLOOR PLAN
SCALE: 1/4" = 1'-0"
D
B
G
H E A
C
F
EM
EM
PS
EM
EM
PS
EM
EM
PS
EM
EM
PS
DS
DS
EM
EM
DS
EM
EM
PS
EM
EM
PS
EM
EM
PS
EM
EM
PS
EM
EM
PS
EM
EM
PS
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
23RESIDENT
ROOM
TOIL.
TOIL.
TOIL.
CLEAN
SOILED
CORR.
TOIL.
RESIDENT
ROOM
SOILED
UTIL.
SPA/BATH/SAFE
ROOM
SAFE
ROOM
LAUNDRY/
CORR.
RESIDENT
ROOM
TOIL.
30LAUNDRY
H.A.C.
CORR.
MEDS
GUEST
TOIL.
CORR.
CLEAN
TOIL.
RESIDENT
ROOM
1RESIDENT
ROOM
TOIL.
4TOIL.
SOILED
RESIDENT
ROOM
RESIDENT
ROOM
TOIL.
STAFF
OFFICE
FOYER
RECEIVING/STORAGE
CORR.
PANTRY
LIVING
ROOM
KITCHEN
MECHANICAL
STORAGE
19B
DATA
ELEC.
17 DINING
ROOM
TOIL.
DS
DS
SUPPLIES/EQUIP.
STOR.
STORAGE
18A
DS
STORAGE
11A
EM
BID DOCUMENTS SUBMISSION
26-E6.0 1/4" = 1'-0"1
FIRE ALARM FLOOR PLAN -
COTTAGE BUILDING #26
26-E6.0.dwg
1 FIRE ALARM CONTROL PANEL.
FIRE ALARM REMOTE ANNUNCIATOR.
CONNECT FIRE ALARM SYSTEM TO SPRINKLER SYSTEM FLOW SWITCH(ES).
CONNECT FIRE ALARM SYSTEM TO SPRINKLER SYSTEM TAMPER SWITCH(ES).
CONNECT 24V FIRE SPRINKLER ALARM BELL TO FIRE ALARM SYSTEM. BELL TO BE
ACTIVATED UPON FIRE SPRINKLER SYSTEM WATER FLOW.
INSTALL A DUCT SMOKE DETECTOR IN RETURN AIR DUCT OF AIR HANDLING UNIT.
PROVIDE DUCT DETECTOR, HOUSING, SAMPLING TUBE, AND AUXILIARY RELAY TO BE
USED TO SHUTDOWN THE UNIT UPON SENSING SMOKE AND CLOSE CORRESPONDING
FIRE/SMOKE DAMPER. INSTALL A REMOTE TEST STATION IN THE CEILING NEAR THE
DETECTOR. CONNECT DETECTOR TO FIRE ALARM SYSTEM. REFER TO MECHANICAL
FLOOR PLAN FOR DETAILS.
CONNECT POWER TO SMOKE DAMPER THROUGH DUCT DETECTOR AUXILIARY RELAY.
INSTALL A DUCT SMOKE DETECTOR IN DUCT WITH SAMPLING TUBE AND AUXILIARY N.O.
CONTACT TO CLOSE WHEN DETECTOR SENSES SMOKE TO OPERATE SMOKE DAMPER.
PROVIDE DUCT DETECTOR, HOUSING, SAMPLING TUBE, AND AUXILIARY RELAY.
CONNECT DETECTOR TO FIRE ALARM SYSTEM.
BUILDING
N.I.C.
N.I.C.
N.I.C.
BUILDING
NO SCALE
KEYPLAN
1. ALL NEW FIRE ALARM DEVICES SHALL BE 100% COMPATIBLE WITH THE EXISTING
NETWORKED SIEMENS FIRE ALARM SYSTEM.
COTTAGE BLDG. 26 -
FIRE ALARM FLOOR PLAN
SCALE: 1/4" = 1'-0"
D
B
G
H E A
C
F
P H
H
P H
H
P H
PH
P H
S
P
S
S
S
S
S
S
S
S
S
S S
SS
S S
S
SS
SS
S S
S S
S
S
S
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
23RESIDENT
ROOM
TOIL.
TOIL.
TOIL.
CLEAN
SOILED
CORR.
TOIL.
RESIDENT
ROOM
SOILED
UTIL.
SPA/BATH/SAFE
ROOM
SAFE
ROOM
LAUNDRY/
CORR.
RESIDENT
ROOM
TOIL.
30LAUNDRY
H.A.C.
CORR.
45MEDS
GUEST
TOIL.
CORR.
CLEAN
TOIL.
RESIDENT
ROOM
RESIDENT
ROOM
TOIL.
4TOIL.
SOILED
RESIDENT
ROOM
RESIDENT
ROOM
TOIL.
STAFF
OFFICE
FOYER
RECEIVING/
STORAGE
CORR.
PANTRY
LIVING
ROOM
KITCHEN
MECHANICAL
STORAGE
19B
DATA
ELEC.
DINING
ROOM
TOIL.
B
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
AHU 26-1
SD
J
J
SD
J
SD
SD
J
SD
8 J
SD
J
SD
J
SD
SD J
JSD
SD
J
C3-68
H
SUPPLIES/EQUIP.
STOR.
STORAGE
18A
S
STORAGE
11A
S
D
D
S
BID DOCUMENTS SUBMISSION
26-E8.0 26-E8.0.dwg
COTTAGE BLDG. 26 -
ELECTRICAL DETAILS
SCALE: NONE
LEGEND
TP- = TIME/PHOTO CONTROLLER - CHANNEL
CONSISTS OF:
1 - HUBBELL CX8 RELAY PANEL (SURFACE MOUNTED)
8 - HUBBELL CRX3L 1-POLE RELAYS
1 - HUBBELL LUXSTATLSO OUTDOOR PHOTOCELL
LIGHTING CONTROL PANEL LCP
DESCRIPTION CCT RELAY T/C
GROUP
P/C
GROUP
P/C
GROUP
T/C
GROUP RELAY CCT DESCRIPTION
DINING/KITCHEN/LIVING LIGHTS C3-67/
C3-69 1 1 - 1 - 5 C3-81 EXTERIOR LIGHTS
CORRIDOR/FOYER LIGHTS C3-69 2 1 - - - 6 - SPARE
CORRIDOR LIGHTS C3-73 3 2 - - - 7 - SPARE
CORRIDOR WALL SCONCES C3-73 4 2 - - - 8 - SPARE
LIGHTING CONTROL RISER DIAGRAM
NO SCALE
TO LIGHTING
LOADS
EACH LOW VOLTAGE SWITCH REQUIRES TWO (2) WIRES:
- POWER (COMMON) WIRE
- RED (SIGNAL) WIRE
C/W ALL PROGRAMMABLE
INTERFACES INSTALLED
AND PRE-PROGRAMMED
SURFACE
FLUSH
PHOTOCELL
HEAD
NUMBER OF CONDUCTORS REQUIRED (#18AWG)
N
NOTES
LEGEND
LOW VOLTAGE SWITCHES
120VAC LIGHTING
CIRCUITS.
LIGHT FIXTURE SCHEDULE
MARK DESCRIPTION HOUSING BALLAST VOLTAGE LENS/NOTES LAMP(S) APPROVED MANUFACTURERS
A RECESSED GRID OR GYPBOARD MOUNTED 6" 19W LED DOWNLIGHT.
5-3/8" NOMINAL HEIGHT, 6" NOMINAL DIAMETER, ALUMINUM REFLECTOR CONE,
CLEAR-ALZAK SEMI-DIFFUSE REFLECTOR CONE, UPPER OPTICAL CHAMBER,
SELF-FLANGED, UNIVERSAL MOUNTING BRACKET, INTEGRATED JUNCTION BOX,
EXTRUDED HEAT SINK, COMPLETE WITH BAR HANGERS, WHITE TRIM.
120V ELECTRONIC LED DRIVER. 120V -
1,500 LUMEN, 19W, 3,500K LED
(PROVIDED WITH FIXTURE).
PRESCOLITE
LF6SL-120-6LFSL-15L-35K-SS-WT-B6
OR PRE-APPROVED EQUAL.
AE RECESSED GRID OR GYPBOARD MOUNTED 6" 19W LED DOWNLIGHT.
5-3/8" NOMINAL HEIGHT, 6" NOMINAL DIAMETER, ALUMINUM REFLECTOR CONE,
CLEAR-ALZAK SEMI-DIFFUSE REFLECTOR CONE, UPPER OPTICAL CHAMBER,
SELF-FLANGED, UNIVERSAL MOUNTING BRACKET, INTEGRATED JUNCTION BOX,
EXTRUDED HEAT SINK, COMPLETE WITH BAR HANGERS, WHITE TRIM.
120V ELECTRONIC LED DRIVER +
EMERGENCY BATTERY PACK. 120V -
1,500 LUMEN, 19W, 3,500K LED
(PROVIDED WITH FIXTURE).
PRESCOLITE
LF6SL-120-EM-6LFSL-15L-35K-SS-EM-WT-B6
OR PRE-APPROVED EQUAL.
B RECESSED GRID OR GYPBOARD MOUNTED 6" 19W LED DOWNLIGHT.
5-3/8" NOMINAL HEIGHT, 6" NOMINAL DIAMETER, ALUMINUM REFLECTOR CONE,
CLEAR-ALZAK SEMI-DIFFUSE REFLECTOR CONE, UPPER OPTICAL CHAMBER,
SELF-FLANGED, UNIVERSAL MOUNTING BRACKET, INTEGRATED JUNCTION BOX,
EXTRUDED HEAT SINK, COMPLETE WITH BAR HANGERS, WHITE TRIM.
120V ELECTRONIC LED DRIVER. 120V -
1,500 LUMEN, 19W, 3,000K LED
(PROVIDED WITH FIXTURE).
PRESCOLITE
LF6SL-120-6LFSL-15L-30K-SS-WT-B6
OR PRE-APPROVED EQUAL.
C 2X4 LENSED RECESSED GYPBOARD MOUNTED LED TROFFER.
3.25" NOMINAL HEIGHT, DIE-FORMED CODE GAUGE COLD ROLLED STEEL, PAINTED
AFTER FABRICATION, OVERLAPPING TRIM TO CONCEAL CEILING OPENING. 120V ELECTRONIC LED DRIVER. 120V A19 PATTERN 0.156" MINIMUM THICKNESS VIRGIN
ACRYLIC LENS.
4,700 LUMEN, 38W, 3,500K LED ARRAY
(PROVIDED WITH FIXTURE).
COLUMBIA
LJT24-35MLG-FSA19-EDU-FK24
OR PRE-APPROVED EQUAL.
CE 2X4 LENSED RECESSED GYPBOARD MOUNTED LED TROFFER.
3.25" NOMINAL HEIGHT, DIE-FORMED CODE GAUGE COLD ROLLED STEEL, PAINTED
AFTER FABRICATION, OVERLAPPING TRIM TO CONCEAL CEILING OPENING.
120V ELECTRONIC LED DRIVER +
EMERGENCY BATTERY PACK. 120V A19 PATTERN 0.156" MINIMUM THICKNESS VIRGIN
ACRYLIC LENS.
4,700 LUMEN, 38W, 3,500K LED ARRAY
(PROVIDED WITH FIXTURE).
COLUMBIA
LJT24-35MLG-FSA19-EDU-EL14-FK24
OR PRE-APPROVED EQUAL.
D 2X2 LENSED RECESSED GRID MOUNTED LED TROFFER. 3.25" NOMINAL HEIGHT, DIE-FORMED CODE GAUGE COLD ROLLED STEEL, PAINTED AFTER FABRICATION. 120V ELECTRONIC LED DRIVER. 120V A19 PATTERN 0.156" MINIMUM THICKNESS VIRGIN
ACRYLIC LENS.
3,300 LUMEN, 31W, 3,500K LED ARRAY
(PROVIDED WITH FIXTURE).
COLUMBIA
LJT22-35MLG-FSA19-EDU-FK22
OR PRE-APPROVED EQUAL.
E 1X4 LENSED RECESSED GYPBOARD MOUNTED LED TROFFER.
3.25" NOMINAL HEIGHT, DIE-FORMED CODE GAUGE COLD ROLLED STEEL, PAINTED
AFTER FABRICATION, OVERLAPPING TRIM TO CONCEAL CEILING OPENING. 120V ELECTRONIC LED DRIVER. 120V A19 PATTERN 0.156" MINIMUM THICKNESS VIRGIN
ACRYLIC LENS.
3,800 LUMEN, 45W, 3,500K LED ARRAY
(PROVIDED WITH FIXTURE).
COLUMBIA
LJT14-35VLG-FSA19-EDU-FK14
OR PRE-APPROVED EQUAL.
F SURFACE MOUNTED DIRECT FIXTURE 4 FT. IN LENGTH. EXTRUDED ALUMINUM HOUSING, DIE-CAST ALUMINUM END CAPS, TEXTURED MATTE WHITE FINISH. 120V ELECTRONIC LED DRIVER. 120V SOFT DIFFUSE ACRYLIC LENS, SINGLE CIRCUIT
OPERATION.
1,000 LUMENS, 9.4W PER FOOT, 3,500K CCT
(PROVIDED WITH FIXTURE).
LITECONTROL
67L-W-D-04-DM-C1-35K-D100-NDM-1C-UNV
OR PRE-APPROVED EQUAL.
G 4 FT. LENSED LED STRIPLIGHT. 3" MINIMUM WIDTH, STEEL HOUSING PAINTED AFTER FABRICATION, PROVIDE WITH
CHAIN HANGING SET. 120V ELECTRONIC LED DRIVER 120V LENSED CLEAR OPTICAL SYSTEM.
5,550 LUMEN, 43W, 3,500K LED
(PROVIDED WITH FIXTURE).
METALUX
4SNLED-LD5-52SL-LC-UNV-L835-CD1-U-AYC-CHAIN/SET
OR PRE-APPROVED EQUAL.
GE 4 FT. LENSED LED STRIPLIGHT. 3" MINIMUM WIDTH, STEEL HOUSING PAINTED AFTER FABRICATION, PROVIDE WITH
CHAIN HANGING SET.
120V ELECTRONIC LED DRIVER +
EMERGENCY BATTERY PACK. 120V LENSED CLEAR OPTICAL SYSTEM.
5,550 LUMEN, 43W, 3,500K LED
(PROVIDED WITH FIXTURE).
METALUX
4SNLED-LD5-52SL-LC-UNV-EL14W-L835-CD1-U-
AYC-CHAIN/SET
OR PRE-APPROVED EQUAL.
H 4 FT. LENSED LED STRIPLIGHT. 3" MINIMUM WIDTH, STEEL HOUSING PAINTED AFTER FABRICATION. 120V ELECTRONIC LED DRIVER 120V LENSED CLEAR OPTICAL SYSTEM.
4,710 LUMEN, 35W, 3,500K LED
(PROVIDED WITH FIXTURE).
METALUX
4SNLED-LD5-46SL-LC-UNV-L835-CD1-U
OR PRE-APPROVED EQUAL.
J RECESSED GRID OR GYPBOARD MOUNTED 6" 14W LED DOWNLIGHT.
5-3/8" NOMINAL HEIGHT, 6" NOMINAL DIAMETER, ALUMINUM REFLECTOR CONE,
CLEAR-ALZAK SEMI-DIFFUSE REFLECTOR CONE, UPPER OPTICAL CHAMBER,
SELF-FLANGED, UNIVERSAL MOUNTING BRACKET, INTEGRATED JUNCTION BOX,
EXTRUDED HEAT SINK, COMPLETE WITH BAR HANGERS, WHITE TRIM.
120V ELECTRONIC LED DRIVER. 120V -
1,100 LUMEN, 14W, 4,000K LED
(PROVIDED WITH FIXTURE).
PRESCOLITE
LF6SL-120-6LFSL-11L-40K-SS-WT-B6
OR PRE-APPROVED EQUAL.
K WALL MOUNTED CUTOFF TYPE LED WALL PACK. ONE PIECE DIE-CAST HOUSING IN SQUARE WEDGE SHAPE, WET LOCATION LISTED, ELECTROSTATICALLY APPLIED BRONZE PAINT AFTER FABRICATION. 120V ELECTRONIC LED DRIVER. 120V TYPE III DISTRIBUTION PATTERN.
4,105 LUMEN, 43W, 4,000K LED ARRAY
(PROVIDED WITH FIXTURE).
HUBBELL LNC2-18LU-4K-3-DB
OR PRE-APPROVED EQUAL.
L WALL MOUNTED CUTOFF TYPE SMALL LED WALL PACK. ALUMINUM HOUSING WITH STAINLESS STEEL HARDWARE, SILICONE GASKETS, UV
RESISTANT POLYESTER POWDER COAT BRONZE FINISH.
120V ELECTRONIC LED DRIVER +
EMERGENCY BATTERY PACK. 120V
TYPE II DISTRIBUTION, TEMPERED GLASS LENS. SET
FIXTURE TO NORMALLY OFF OPERATION AND
EMERGENCY BATTERY BACKUP SHALL ONLY
OPERATE UPON LOSS OF POWER.
1,320 LUMEN, 14W, 4,000K LED ARRAY
(PROVIDED WITH FIXTURE).
TRACE-LITE
TLED-NFS-14-VS-4K-BB
OR PRE-APPROVED EQUAL.
M RECESSED GRID OR GYPBOARD MOUNTED 6" 14W LED DOWNLIGHT.
5-3/8" NOMINAL HEIGHT, 6" NOMINAL DIAMETER, ALUMINUM REFLECTOR CONE,
CLEAR-ALZAK SEMI-DIFFUSE REFLECTOR CONE, UPPER OPTICAL CHAMBER,
SELF-FLANGED, UNIVERSAL MOUNTING BRACKET, INTEGRATED JUNCTION BOX,
EXTRUDED HEAT SINK, COMPLETE WITH BAR HANGERS, WHITE TRIM.
120V ELECTRONIC LED DRIVER. 120V -
1,100 LUMEN, 14W, 3,000K LED
(PROVIDED WITH FIXTURE).
PRESCOLITE
LF6SL-120-6LFSL-11L-30K-SS-WT-B6
OR PRE-APPROVED EQUAL.
N 6" ROUND CYLINDER 33W LED DOWNLIGHT.
13.5" NOMINAL HEIGHT, 6" NOMINAL DIAMETER, 18" PENDANT MOUNT, SEAMLESS
HEAVY GAUGE EXTRUDED ALUMINUM HOUSING, WHITE PAINTED REFLECTOR
CONE, MATTE WHITE HOUSING FINISH.
120V ELECTRONIC LED DRIVER. 120V -
2,400 LUMEN, 33W, 3,500K LED
(PROVIDED WITH FIXTURE).
PRESCOLITE
LCC6LED-P-24L-35K-8-WFL45-WC-WH
OR PRE-APPROVED EQUAL.
P WALL MOUNTED STRAIGHT 3-LIGHT DECORATIVE BAR. 9"H X 21"W X 6.25"D BRUSHED NICKEL FINISH MOUNTING PLATE AND BAR WITH
THREE FLAT RIMMED CREAM COLORED SHADES.
(3) 120V SELF-BALLASTED LED LAMPS. 120V -
THREE 10W, 3,000K, GU-24 BASE SELF-BALLASTED LEDS
(PROVIDED WITH FIXTURE).
JUSTICE DESIGN GROUP
CNDL-8773-GU24LED-10-NCKL-CREM
OR PRE-APPROVED EQUAL.
Q WALL MOUNTED DECORATIVE WALL SCONCE. 9.75"H X 6.5"W X 4"D BRUSHED NICKEL FINISH MOUNTING PLATE WITH ONE OVAL
CREAM COLORED SHADE.
(1) 120V SELF-BALLASTED LED LAMP. 120V -
ONE 10W, 3,500K, GU-24 BASE SELF-BALLASTED LED LAMP
(PROVIDED WITH FIXTURE).
JUSTICE DESIGN GROUP
CNDL-8707-GU24LED-30-NCKL-CREM
OR PRE-APPROVED EQUAL.
R LED NIGHTLIGHT.
DIE CAST ALUMINUM FACEPLATE AND REFLECTOR POLYESTER POWDER COAT
SOFT WHITE, 16 GAUGE GALVANIZED STEEL BACK BOX. 120V ELECTRONIC LED DRIVER. 120V CUSTOM ACRYLIC MOLDED LENS, WHITE LED COLOR. LED (FURNISHED). ALKCO WAYGLO LED NIGHTLIGHT WG2V-1-SWH OR
PRE-APPROVED EQUAL.
S 16" SQUARE FLUSH-MOUNT DECORATIVE FIXTURE. 16" SQUARE BRUSHED NICKEL FINISH WITH "FIZZ" COLORED SHADE. 120V ELECTRONIC LED DRIVER. 120V -
3,000 LUMEN, 39W, 3,000K LED
(PROVIDED WITH FIXTURE).
JUSTICE DESIGN GROUP
3FRM-5557-LED-NCKL-FIZZ
OR PRE-APPROVED EQUAL.
T 6" ROUND CYLINDER 18W LED DOWNLIGHT.
13.5" NOMINAL HEIGHT, 6" NOMINAL DIAMETER, 18" PENDANT MOUNT, SEAMLESS
HEAVY GAUGE EXTRUDED ALUMINUM HOUSING, WHITE PAINTED REFLECTOR
CONE, MATTE WHITE HOUSING FINISH.
120V ELECTRONIC LED DRIVER. 120V -
1,400 LUMEN, 18W, 3,500K LED
(PROVIDED WITH FIXTURE).
PRESCOLITE
LCC6LED-P-14L-35K-8-WFL45-WC-WH
OR PRE-APPROVED EQUAL.
U PENDANT MOUNTED DECORATIVE FIXTURE.
12" DIAMETER, 7" HIGH ROUND STEEL HOUSING, SPUN HEAVY-GAUGE ALUMINUM
REFLECTOR, WHITE POWDER COAT FINISH. (1) 120V SELF-BALLASTED LED LAMP. 120V -
ONE 10W, 3,500K, SELF-BALLASTED LED LAMP
(PROVIDED WITH FIXTURE).
BASELITE
CS12-44-10WLED-STEM
OR PRE-APPROVED EQUAL.
V 18" PENDANT BOWL DECORATIVE FIXTURE.
18" SQUARE X 24" OVERALL HEIGHT, BRUSHED NICKEL CANOPY AND STEM FINISH,
SQUARE BOWL, FINIALS AS SELECTED BY ARCHITECT. 120V ELECTRONIC LED DRIVER. 120V -
3,000 LUMEN, 39W, 3,000K LED
(PROVIDED WITH FIXTURE).
JUSTICE DESIGN GROUP
CLD-9661-25-NCKL-XX
OR PRE-APPROVED EQUAL.
W SMALL OPEN TOP AND BOTTOM CYLINDER. 10.5"H x 7.25"W x 5" PROJECTION. RESIN SHADE MATERIAL. (1) 120V SELF-BALLASTED LED LAMP. 120V -
ONE 10W, 3,500K, SELF-BALLASTED LED LAMP
(PROVIDED WITH FIXTURE).
JUSTICE DESIGN GROUP
CLD-0945W
OR PRE-APPROVED EQUAL.
X L.E.D. EXIT SIGN.
THIN PROFILE WHITE ALUMINUM HOUSING, WHITE ALUMINUM STENCIL FACE,
NUMBER OF FACES AND DIRECTIONAL ARROWS AS INDICATED ON DRAWINGS,
DIFFUSE RED FACE PANEL(S).
- 120V
NI-CAD BATTERY PACK AND CHARGER WITH TEST
SWITCH AND CHARGING INDICATOR, 20 YEAR RATED
LAMP LIFE, MUST MEET UL 924 REQUIREMENTS.
L.E.D. (FURNISHED) LITHONIA LE, DUAL-LITE SC, MCPHILBEN ER55L OR
SURE-LITES CAX.
XY COMBINATION L.E.D. EXIT SIGN/EMERGENCY LIGHTING UNIT.
THIN PROFILE WHITE ALUMINUM HOUSING, WHITE ALUMINUM STENCIL FACE,
NUMBER OF FACES AND DIRECTIONAL ARROWS AS INDICATED ON DRAWINGS,
DIFFUSE RED FACE PANEL(S), INTEGRAL LED EMERGENCY LIGHTS IN A
LOW-PROFILE DESIGN PROTECTED BY A POLYCARBONATE SHIELD, UNIVERSAL
MOUNTING.
- 120V
NI-CAD BATTERY PACK AND CHARGER WITH TEST
SWITCH AND CHARGING INDICATOR, 20 YEAR RATED
LAMP LIFE, MUST MEET UL 924 REQUIREMENTS.
L.E.D. (FURNISHED). EXITRONIX 400C SERIES OR PRE-APPROVED EQUAL.
Z 3 FT. UNDERCABINET LED TASK LIGHT.
1.25 INCH NOMINAL HEIGHT MINIMUM 20 GAUGE SOLID FRONT HOUSING,
POLYESTER POWDER COAT WHITE. NO CONVENIENCE OUTLET OR ROCKER
SWITCH.
HIGH POWER FACTOR ELECTRONIC
CONSTANT-CURRENT 120V DRIVER. 120V EXTRUDED FROST 100% DR ACRYLIC LENS.
700 LUMEN, 11W, 3,500K LED ARRAY
(PROVIDED WITH FIXTURE).
KENALL AUCLED-I-MW-16L35K-36-120
OR PRE-APPROVED EQUAL.
GENERAL NOTES:
A. ELECTRONIC BALLASTS:
1. GENERIC ELECTRONIC BALLASTS ARE NOT ACCEPTABLE.
2. ALL LINEAR FLUORESCENT BALLASTS SHALL BE RAPID START OR UNIVERSAL ACCUSTART.
3. BALLASTS FOR LINEAR T8 AND COMPACT T5 FLUORESCENT LAMPS SHALL HAVE MAXIMUM 10% TOTAL HARMONIC DISTORTION, MINIMUM 0.87 BALLAST FACTOR, AND MAXIMUM 1.7 CREST FACTOR.
4. BALLASTS FOR COMPACT FLUORESCENT T4 LAMPS (32W AND 42W) SHALL BE ELECTRONIC, WITH A MAXIMUM OF 20% TOTAL HARMONIC DISTORTION AND A MINIMUM 0.87 BALLAST FACTOR.
5. BALLASTS SHALL OPERATE NO MORE THAN 2 LAMPS.
6. REFER TO THE SPECIFICATIONS FOR COMPLETE DETAILS.
7. REFER TO THE FIXTURE DESCRIPTION FOR BALLAST VOLTAGE.
8. PROVIDE SPARE BALLASTS AS REQUIRED IN THE SPECIFICATIONS. DELIVER TO THE OWNER AT THE COMPLETION OF THE PROJECT.
B. LAMPS:
1. BOTH COMPACT AND LINEAR FLUORESCENT LAMPS SHALL BE BY THE SAME MANUFACTURER UNLESS APPROVED OTHERWISE.
2. PROVIDE SPARE LAMPS AS REQUIRED IN THE SPECIFICATIONS. DELIVER TO THE OWNER AT THE COMPLETION OF THE PROJECT.
C. FIXTURES:
1. ALL TROFFER ACRYLIC LENSES SHALL HAVE A MINIMUM THICKNESS OF 0.125" WITH STRAIGHT PYRAMIDAL PRISM SIDES AND A MINIMUM WEIGHT OF 7.8 OUNCES PER SQUARE FOOT.
2. WHERE A "FIXTURE SERIES" IS LISTED, ALL LISTED MANUFACTURER'S SERIES ARE PRE-APPROVED PROVIDED THE ACTUAL PRODUCTS MEET THE DESCRIPTION. ALL OTHERS REQUIRE PRE-APPROVAL. WHERE ONLY ONE OR TWO SPECIFIC FIXTURES ARE LISTED, ALL OTHER MANUFACTURER'S PRODUCT SUBSTITUTIONS REQUIRE PRE-APPROVAL.
3. FIXTURE CATALOG NUMBERS FOR "FIXTURE SERIES" ARE NOT COMPLETE AND ARE INTENDED ONLY TO INDICATE THE GENERAL FIXTURE SERIES TO BE PROVIDED.PROVIDE COMPLETE CATALOG NUMBERS UPON SUBMITTAL TO MATCH ALL FIXTURE REQUIREMENTS DESCRIBED.
4. ALL LIGHTING FIXTURES INSTALLED IN INACCESSIBLE CEILINGS SHALL BE SERVICEABLE FROM BELOW, WHERE COMPONENT SERVICE (SUCH AS BALLAST REPLACEMENT) IS REQUIRED.
LEGEND
SPST WALL SWITCH, 20A, 120V.
SWITCH STATION FOR LIGHTING CONTROL SYSTEM. TYPE AS NOTED.
WALL MOUNTED INFRARED OCCUPANCY SENSOR, 120V, MINIMUM 800W, EQUAL TO WATTSTOPPER
PW-100.
WALL MOUNTED DUAL-TECHNOLOGY OCCUPANCY SENSOR, 120V, MINIMUM 800W, EQUAL TO
WATTSTOPPER DW-100.
DUPLEX RECEPTACLE, 20A, 125V. MOUNT AT STANDARD RECEPTACLE HEIGHT UNLESS DENOTED BY AC
"ABOVE COUNTER" OR BC "BELOW COUNTER".
DOUBLE DUPLEX RECEPTACLES, 20A, 125V. MOUNT AT STANDARD RECEPTACLE HEIGHT UNLESS
DENOTED BY AC "ABOVE COUNTER" OR BC "BELOW COUNTER".
DUPLEX RECEPTACLE, 20A 125V, WITH WEATHERPROOF COVER. MOUNT AT STANDARD RECEPTACLE
HEIGHT UNLESS DENOTED BY AC "ABOVE COUNTER" OR BC "BELOW COUNTER".
DUPLEX RECEPTACLE, 20A 125V, GROUND FAULT INTERRUPTER. MOUNT AT STANDARD RECEPTACLE
HEIGHT UNLESS DENOTED BY AC "ABOVE COUNTER" OR BC "BELOW COUNTER".
DUPLEX RECEPTACLE, 20A 125V, GROUND FAULT INTERRUPTER W/ WEATHERPROOF COVER. MOUNT AT STANDARD RECEPTACLE HEIGHT UNLESS DENOTED BY AC "ABOVE COUNTER" OR BC "BELOW COUNTER".
SIMPLEX RECEPTACLE. TYPE AS NOTED.
FLOORBOX. TYPE AS NOTED.
JUNCTION BOX MOUNTED ABOVE CEILING LINE, 4" SQUARE WITH BLANK COVER.
EQUIPMENT CONNECTION OR WALL JUNCTION BOX. FOR WALL JUNCTION BOX, PROVIDE 4" SQUARE BOX
WITH SINGLE GANG RING AND 1" EMT TO CEILING SPACE. FURNISH BLANK PLATE.
MOTOR OPERATED EQUIPMENT FURNISHED BY OTHERS AND CONNECTED BY ELECTRICAL CONTRACTOR.
GENERAL DUTY NON-FUSED SAFETY SWITCH, AMPACITY AND NUMBER OF POLES AS NOTED. FURNISH NEMA 1 OR NEMA 3R ENCLOSURE AS REQUIRED. SEE MECHANICAL EQUIPMENT CONNECTION CHART.
GENERAL DUTY FUSED SAFETY SWITCH, AMPACITY AND NUMBER OF POLES AS NOTED. FURNISH NEMA 1
OR NEMA 3R ENCLOSURE AS REQUIRED. SEE MECHANICAL EQUIPMENT CONNECTION CHART.
BRANCH CIRCUIT DESIGNATION. IF NO CROSS MARKS ARE SHOWN, CIRCUIT CONTAINS TWO CURRENT CARRYING CONDUCTORS AND ONE GROUNDING CONDUCTOR. IF MORE THAN TWO CURRENT CARRYING CONDUCTORS ARE REQUIRED, CROSS LINES INDICATE THE FOLLOWING: SHORT CROSS LINE INDICATES NEUTRAL CONDUCTOR, LONG CROSS LINE INDICATES HOT OR SWITCHED CONDUCTOR, LONG CROSS
LINE WITH DOT INDICATES ADDITIONAL ISOLATED GROUNDING CONDUCTOR.
ARROW WITH CIRCUIT NUMBER INDICATES HOMERUN AND PANEL CIRCUIT NUMBER.
DATA OUTLET(S) IN A 4" SQUARE J-BOX WITH SINGLE GANG RING AND 3/4" EMT TO ACCESSIBLE CEILING SPACE. NUMBER NEXT TO SYMBOL INDICATES NUMBER OF JACKS. MOUNT AT STANDARD RECEPTACLE
HEIGHT UNLESS DENOTED BY AC "ABOVE COUNTER" OR BC " BELOW COUNTER.
VOICE OUTLET(S) IN A 4" SQUARE J-BOX FOR WALL MOUNTED PHONE WITH SINGLE GANG RING AND 3/4"
EMT TO ACCESSIBLE CEILING SPACE. MOUNT 60 IN. AFF.
COMBINATION VOICE AND DATA OUTLETS, 4" SQUARE WITH SINGLE GANG RING AND TWO 3/4" EMT TO ACCESSIBLE CEILING SPACE. MOUNT AT STANDARD RECEPTACLE HEIGHT UNLESS DENOTED BY AC "ABOVE COUNTER" OR BC " BELOW COUNTER. NUMBER NEXT TO SYMBOL INDICATES NUMBER OF DATA
JACKS.
ONE DATA CABLE LOCATED ABOVE CEILING FOR WIRELESS ACCESS POINT (BY OTHERS). PROVIDE RJ-45 JACK ON END OF CABLE. PROVIDE MINIMUM OF 25 FEET OF COILED CABLE TO ALLOW FOR FUTURE
RELOCATION.
COMBINATION F-TYPE TV/DATA OUTLET. REFER TO ARCHITECTURAL FOR EXACT MOUNTING LOCATION.
FIRE ALARM MANUAL PULL STATION.
FIRE ALARM DUCT SMOKE DETECTOR.
FIRE ALARM AREA SMOKE DETECTOR.
FIRE ALARM HORN STROBE.
FIRE ALARM MAGNETIC DOOR HOLDER.
FIRE ALARM RELAY OR MODULE AS NOTED.
SINGLE GANG J-BOX WITH 3/4" EMT TO ACCESSIBLE CEILING SPACE FOR SPACE TEMPERATURE SENSOR.
VERIFY ORIENTATION WITH MECHANICAL CONTRACTOR.
NURSE CALL PATIENT STATION.
NURSE CALL EMERGENCY STATION.
NURSE CALL DOME LIGHT.
L
PI
DT
WP
GFI
GFI
WP
J
J
B-12
W
WA
TVD
P
SD
S
H
D
S
PS
BID DOCUMENTS SUBMISSION
26-E8.1 26-E8.1.dwg
COTTAGE BLDG. 26 -
ELECTRICAL DETAILS
SCALE: NONEPOWER RISER DIAGRAM
NO SCALE
GRADE
EXISTING
DISTRIBUTION
SWITCHBOARD
DP
NEW
PANEL
C3M
EXISTING TWO 3"C. ROUTED BELOW GRADE.
INTERCEPT CONDUITS AND EXTEND TO COTTAGE
MAIN DISCONNECT SWITCH. INSTALL 4-350KCM,
1-1GND FROM 600/3 C/B IN PANEL DP THROUGH EACH
EXISTING CONDUIT AND THROUGH CONDUIT
EXTENSIONS TO COTTAGE PANEL C3M. REFER TO
OVERALL ELECTRICAL SITE PLAN FOR DETAILS.
TWO 3"C. EACH WITH 4-350KCM, 1-1GND.
4-4/0, 1-4GND, 2-1/2"C.
CONNECT TO EXISTING 600/3 C/B INSTALLED DURING
PHASE 1 CONSTRUCTION. EXISTING DISTRIBUTION
SWITCHBOARD DP IS A SQUARE D QED SERIES 2 208Y/120V
3Ø 4W 2000A SWITCHBOARD. CONTRACTOR TO VERIFY.
PROVIDE ENGRAVED LABEL NOTING C/B OPERATION.
NEW
PANEL
C3
SECT. #1
NEW
PANEL
C3
SECT. #2
NEW
PANEL
C3
SECT. #3
4-4/0, 1-4GND, 2-1/2"C.
BID DOCUMENTS SUBMISSION
26-E8.2 26-E8.2.dwg
COTTAGE BLDG. 26 -
ELECTRICAL DETAILS
SCALE: NONE
TYPICAL 4 POSITION COMBINATION DATA/VOICE
OUTLET W/ GREEN CATEGORY 6 RJ-45 DATA JACKS
AND 1 WHITE CATEGORY 6 RJ-45 VOICE JACK
MOUNTED IN UPPER LEFT POSITION. NUMBER NEXT
TO SYMBOL INDICATES NUMBER OF DATA JACKS.
TYPICAL DATA OUTLET W/ GREEN CATEGORY 6 RJ-45 DATA JACKS.
NUMBER NEXT TO SYMBOL INDICATES NUMBER OF DATA JACKS.
TYPICAL VOICE OUTLET W/ ONE WHITE CATEGORY 6
RJ-45 VOICE JACK FOR WALL MOUNTED PHONE.
DATA/VOICE/TV RISER DIAGRAM
NO SCALE
GRADE
BUILDING 25
DATA ROOM
EXISTING DATA RACK.
GRADE
BUILDING 26
DATA ROOM
W
ONE 3/4" EMT TO
ACCESSIBLE
CEILING SPACE.
TWO 3/4" EMT TO
ACCESSIBLE CEILING
SPACE.
ONE GREEN CAT6 DATA CABLE
FROM EACH DATA JACK AND VOICE
JACK TO PATCH PANEL IN RACK.
TV D
COMBINATION DATA/TV OUTLET (TYP.).
VERIFY REQUIREMENTS WITH OWNER.
EXISTING
MANHOLE.
EXISTING CONDUITS BETWEEN MANHOLE AND BUILDING 25 DATA
ROOM. INSTALL NEW COMMUNICATION CABLING IN EXISTING
SPARE CONDUITS AS POSSIBLE. CONTRACTOR TO VERIFY.
REFER TO OVERALL ELECTRICAL SITE PLAN FOR DETAILS.
NEW CONDUITS BETWEEN MANHOLE AND
BUILDING 26 DATA ROOM. REFER TO OVERALL
ELECTRICAL SITE PLAN FOR DETAILS.
INSTALL ONE NEW 12 STRAND FIBER
OPTIC CABLE IN 1" INNERDUCT BETWEEN
EXISTING DATA RACK IN BUILDING 25
AND NEW DATA RACK IN COTTAGE 26.
INSTALL ONE NEW 12 STRAND FIBER
OPTIC CABLE IN 1" INNERDUCT BETWEEN
EXISTING DATA RACK IN BUILDING 25
AND NEW DATA RACK IN COTTAGE 26.
NEW 84" TWO-POST FLOOR
MOUNTED DATA RACK WITH
VERTICAL WIRE MANAGEMENT.
RG-6 75 OHM COAX CABLE
FROM F-TYPE TV OUTLET(S)
TO SPLITTER(S) MOUNTED
ON WALL IN DATA ROOM.
CABLE TV
SPLITTER(S)
MOUNTED ON WALL
IN DATA ROOM.
P
ADDRESSABLE FIRE
ALARM CONTROL PANEL
ANNUNCIATOR WIRING
FIRE ALARM PULL
STATION (TYP.)
TYPICAL MONITOR MODULE AT SPRINKLER
SYSTEM FLOW SWITCH(ES).
TYPICAL MONITOR MODULE AT TAMPER
SWITCH(ES).
S
CEILING MOUNTED
SMOKE DETECTOR.
END OF LINE RESISTOR (TYP.)
TYPICAL ADDRESSABLE MODULE OR RELAY.
FLUSH MOUNTED REMOTE
ANNUNCIATOR.
H
END OF LINE RESISTOR (TYP.)
TYPICAL HORN/STROBE.
NAC CIRCUIT
FIRE ALARM RISER DIAGRAM
NO SCALE
C3-66
TYPICAL RELAY MODULE AT ALARM BELL.
SIGNAL AND LINE
CIRCUIT
B
FIRE SPRINKLER BELL.
NAC CIRCUIT24VAC POWER SUPPLY
(SUPPLIES) AS REQUIRED.
H
END OF LINE RESISTOR (TYP.)
SB
CEILING MOUNTED
SMOKE DETECTOR W/
SOUNDER BASE.
TYPICAL STROBE.
TYPICAL HORN/STROBE.
TYPICAL STROBE.
EXISTING
MANHOLE.
EXISTING CONDUITS BETWEEN MANHOLE AND BUILDING 25
DATA ROOM. INSTALL NEW FIRE ALARM CABLING IN EXISTING
SPARE CONDUITS AS POSSIBLE. CONTRACTOR TO VERIFY.
REFER TO OVERALL ELECTRICAL SITE PLAN FOR DETAILS.
CONNECT BUILDING 26 FIRE ALARM CONTROL PANEL TO
EXISTING BUILDING 25 FIRE ALARM CONTROL PANEL AND
BUILDING 27 FIRE ALARM CONTROL WITH FIBER OPTIC
CABLE AS NECESSARY. REFER TO OVERALL ELECTRICAL
SITE PLAN FOR CONDUIT ROUTING DETAILS.
NURSE CALL BASE MASTER STATION.
INSTALL NEW NURSE CALL CENTRAL
EQUIPMENT IN DATA 16. EQUIPMENT
MUST BE 100% COMPATIBLE WITH THE
EXISTING HILL-ROM NURSE CALL SYSTEM.
NURSE CALL DOME LIGHT
(TYP.)
NURSE CALL PATIENT STATION
(TYP.)
EM PSDS
NURSE CALL EMERGENCY STATION WITH
PULL CORD HUNG WITHIN 6 INCHES AFF.
(TYP.)
NURSE CALL DUTY STATION
(TYP.)
NURSE CALL RISER DIAGRAM
NO SCALE
BID DOCUMENTS SUBMISSION
27-E1.0 1/4" = 1'-0"1
POWER FLOOR PLAN -
COTTAGE BUILDING #27
27-E1.0.dwg
BUILDING
N.I.C.
N.I.C.
N.I.C.
BUILDING
NO SCALE
KEYPLAN
1 UNDERGROUND FEEDER CONDUIT AND CABLES. SEE POWER RISER DIAGRAM FOR
DETAILS.
PANEL C3M.
PANEL C3 (3-SECTION).
RECEPTACLE FOR TV. VERIFY EXACT MOUNTING LOCATION WITH ARCHITECT.
RECEPTACLE MOUNTED HIGH ON WALL FOR LIFT TRACK BATTERY CHARGER. VERIFY
EXACT MOUNTING LOCATION WITH EQUIPMENT INSTALLER.
20A 120VAC SIMPLEX RECEPTACLE MOUNTED AT STANDARD RECEPTACLE HEIGHT FOR
PATIENT BED. HOMERUN 2-12, 1-12G, 3/4"C.
DEDICATED RECEPTACLE FOR REFRIGERATOR MOUNTED AT STANDARD RECEPTACLE
HEIGHT. HOMERUN 2-12, 1-12G, 3/4"C.
DEDICATED RECEPTACLE FOR RECLINING BATHING SYSTEM MOUNTED AT STANDARD
RECEPTACLE HEIGHT. HOMERUN 2-12, 1-12G, 3/4"C.
DEDICATED RECEPTACLE FOR WASHING MACHINE. HOMERUN 2-12, 1-12G, 3/4"C.
30A 250V I PHASE 3-WIRE AND GROUND STRAIGHT BLADE NEMA 14-30R RECEPTACLE
FOR DRYER. PROVIDE MATCHING #10/3 AND GROUND CORD AND PLUG. HOMERUN 3-10,
1-10 GND, 3/4" C.
DEDICATED RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR. HOMERUN 2-12,
1-12G, 3/4"C. REFER TO ARCHITECTURAL FOR DETAILS.
DEDICATED RECEPTACLE FOR COUNTERTOP PRINTER. HOMERUN 2-12, 1-12G, 3/4"C.
REFER TO ARCHITECTURAL FOR DETAILS.
INSTALL PUSHBUTTON STATION FOR MOTOR OPERATED OVERHEAD DOOR PROVIDED
WITH DOOR. COORDINATE DETAILS WITH EQUIPMENT PROVIDED.
CONNECT TO MOTOR OPERATED OVERHEAD DOOR. HOMERUN 2-12, 1-12G, 3/4"C.
COORDINATE DETAILS WITH EQUIPMENT PROVIDED.
CONNECT TO ELECTRIC FIREPLACE. HOMERUN 2-12, 1-12G, 3/4"C. COORDINATE
DETAILS WITH EQUIPMENT PROVIDED.
INSTALL A NEMA 6-20 1Ø 250V RECEPTACLE BELOW COUNTER FOR HOT WELLS. REFER
TO ARCHITECTURAL FOR EXACT MOUNTING LOCATION. PROVIDE MATCHING CORD AND
PLUG IF NECESSARY. CONTRACTOR TO VERIFY. HOMERUN 2-12, 1-12G, 3/4"C.
INSTALL A NEMA 5-20 1Ø 120V RECEPTACLE BELOW COUNTER FOR DRINK DISPENSER.
REFER TO ARCHITECTURAL FOR EXACT MOUNTING LOCATION. PROVIDE MATCHING
CORD AND PLUG IF NECESSARY. CONTRACTOR TO VERIFY. HOMERUN 2-12, 1-12G,
3/4"C.
CONNECT TO BUILT IN OVEN. HOMERUN 3-8, 1-10G, 1"C. VERIFY DETAILS AND
REQUIREMENTS WITH EQUIPMENT PROVIDED.
DEDICATED RECEPTACLE FOR LOCATED ABOVE COUNTER FOR MICROWAVE.
HOMERUN 2-12, 1-12G, 3/4"C. REFER TO ARCHITECTURAL FOR DETAILS.
CONNECT TO COOKTOP. HOMERUN 3-8, 1-10G, 1"C. VERIFY DETAILS AND
REQUIREMENTS WITH EQUIPMENT PROVIDED.
CONNECT TO RANGE HOOD. HOMERUN 2-12, 1-12G, 3/4"C. VERIFY DETAILS AND
REQUIREMENTS WITH EQUIPMENT PROVIDED.
DEDICATED RECEPTACLE FOR REFRIGERATOR MOUNTED AT 48 IN. AFF. HOMERUN
2-12, 1-12G, 3/4"C.
CONNECT TO AUTOMATIC DOOR OPENER. COORDINATE DETAILS AND REQUIREMENTS
WITH EQUIPMENT INSTALLER.
DEDICATED RECEPTACLE LOCATED BELOW COUNTER FOR GARBAGE DISPOSER.
HOMERUN 2-12, 1-12G, 3/4"C. INSTALL SWITCH ABOVE COUNTER TO CONTROL
RECEPTACLE. REFER TO ARCHITECTURAL FOR DETAILS.
DEDICATED RECEPTACLE LOCATED BELOW COUNTER FOR DISHWASHER. HOMERUN
2-12, 1-12G, 3/4"C. REFER TO ARCHITECTURAL FOR DETAILS.
FLUSH FLOOR BOX, 3 COMPARTMENT (WIREMOLD 880CS-3 OR EQUAL). ONE
COMPARTMENT WITH A DUPLEX RECEPTACLE, ONE COMPARTMENT FOR FUTURE
DATA/VOICE JACKS AND ONE COMPARTMENT WITH BLANK COVER. PROVIDE FLUSH
BRASS CARPET AND TILE FLANGE (WIREMOLD 837B OR EQUAL), FLIP-TOP DUPLEX
RECEPTACLE COVER PLATE (WIREMOLD 828R OR EQUAL), COMMUNICATIONS COVER
PLATE (WIREMOLD 828COMTC OR EQUAL) AND COMMUNICATIONS COVER PLATE
(829CK-3/4 OR EQUAL). VERIFY EXACT LOCATION WITH THE ARCHITECT. HOMERUN 2-12,
1-12G, 3/4"C. BELOW SLAB TO WALL AS SHOWN, THEN UP IN WALL TO ACCESSIBLE
CEILING SPACE, THEN TO PANEL. INSTALL ONE 1"C. BELOW SLAB FROM
COMMUNICATIONS COMPARTMENT TO WALL AS SHOWN, THEN UP TO ACCESSIBLE
CEILING SPACE FOR FUTURE DATA CABLING AND ONE 1-1/4"C. BELOW SLAB FROM
SPARE COMPARTMENT TO WALL AS SHOWN, THEN UP TO ACCESSIBLE CEILING SPACE.
PROVIDE FULL LENGTH PULL STRING IN SPARE 1-1/4"C.
FLUSH FLOOR BOX, 3 COMPARTMENT (WIREMOLD 880CS-3 OR EQUAL). ONE
COMPARTMENT WITH A DUPLEX RECEPTACLE, ONE COMPARTMENT FOR FUTURE
DATA/VOICE JACKS AND ONE COMPARTMENT WITH BLANK COVER. PROVIDE FLUSH
BRASS CARPET AND TILE FLANGE (WIREMOLD 837B OR EQUAL), FLIP-TOP DUPLEX
RECEPTACLE COVER PLATE (WIREMOLD 828R OR EQUAL), COMMUNICATIONS COVER
PLATE (WIREMOLD 828COMTC OR EQUAL) AND COMMUNICATIONS COVER PLATE
(829CK-3/4 OR EQUAL). VERIFY EXACT LOCATION WITH THE ARCHITECT. ROUTE 2-12,
1-12G, 3/4"C. BELOW SLAB TO NEXT FLOOR BOX AS SHOWN. INSTALL ONE 1"C. BELOW
SLAB FROM COMMUNICATIONS COMPARTMENT TO NEXT FLOOR BOX AS SHOWN FOR
FUTURE DATA CABLING AND ONE 1-1/4"C. BELOW SLAB FROM SPARE COMPARTMENT
TO NEXT FLOOR BOX AS SHOWN.
COTTAGE BLDG. 27 -
POWER FLOOR PLAN
SCALE: 1/4" = 1'-0"
D
B
G
HEA
C
F
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
J
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
GFI
GFI
H
GFI
GFI
GFI
GFI
AC
+48
J
BCBC
BC
BC
AC
J
BC BC
BC
BC
BC
BC
GFI
GFI
GFI
GFI
GFI
C4-1
C4-3
(ON)
C4-5
(ON)
C4-5
(ON)
C4-3
(ON)
C4-7
C4-15
C4-11
(ON)
C4-13
(ON)
C4-13
(ON)
C4-11
(ON)
C4-9
C4-31
C4-27
(ON)
C4-29
(ON)
C4-29
(ON)
C4-27
(ON)
C4-25
C4-17
C4-19
(ON)
C4-21
(ON)
C4-21
(ON)
C4-19
(ON)
C4-23
C4-33
6C4-35
(ON)
C4-37
(ON)
C4-39
C4-35
(ON)
C4-37
(ON)
C4-2
C4-20
C4-12
7 C4-14
C4-10
C4-18
H
WP
GFI
C4-16 8
C4-22
C4-24
C4-28
C4-26
C4-30
C4-36
(ON)
C4-36
(ON)
C4-36
(ON)
C4-40,42
C4-44,46
C4-48
J
J C4-54,56
C4-53
C4-55
C4-50
C4-57
C4-58,60
C4-52
C4-59
C4-61
C4-62C4-64
C4-34
C4 -4
C4-51 C4-49
C4-45
C4-43
C4-41
(ON)
C4-41
(ON)
C4-41
(ON)
C4-41
(ON)
C4-41
(ON)
C4-32
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
23 RESIDENT
ROOM
TOIL.
TOIL.
TOIL.
CLEAN
SOILED
CORR.
TOIL.
RESIDENT
ROOM
SOILED
UTIL.
SPA/BATH/SAFE
ROOM
SAFE
ROOM
LAUNDRY/
CORR.
RESIDENT
ROOM
31 TOIL.
30 LAUNDRY
H.A.C.
CORR.
MEDS
GUEST
TOIL.
CORR.
CLEAN
TOIL.
RESIDENT
ROOM
1 RESIDENT
ROOM
TOIL.
4 TOIL.
SOILED
RESIDENT
ROOM
RESIDENT
ROOM
TOIL.
STAFF
OFFICE
FOYER
RECEIVING/STORAGE
CORR.
PANTRY
LIVING
ROOM
KITCHEN
MECHANICAL
STORAGE
19B
DATA
ELEC.
17DINING
ROOM
TOIL.
AC
GFI
C4-70
GFI
AC
GFI
AC
GFI
AC
GFI
AC
GFI
AC
BC
J
C4-72
(ON)
J
C4-72
(ON)
J
C4-74
(ON)
SUPPLIES/EQUIP.
STOR.
STORAGE
18A
C4-38
STORAGE
11A
GFIGFI
GFI
GFI GFI
+48
+48
+48
+48
+48
+48
AC
GFI
+48
GFI
GFI
GFI
C4-6,8
C4-4
C4-78
BID DOCUMENTS SUBMISSION
27-E2.0 1/4" = 1'-0"1
EQUIPMENT POWER FLOOR PLAN -
COTTAGE BUILDING #27
27-E2.0.dwg
BUILDING
N.I.C.
N.I.C.
N.I.C.
BUILDING
1. REFER TO SHEET 27-E8.1 FOR MECHANICAL EQUIPMENT CONNECTION CHART.
PANEL C4M.
CONNECT TO AIR HANDLER UNIT SUPPLY FANS VFD. REFER TO MECHANICAL
EQUIPMENT CONNECTION CHART FOR DETAILS.
CONNECT TO CONDENSING UNIT. REFER TO MECHANICAL EQUIPMENT CONNECTION
CHART FOR DETAILS.
CONNECT TO FAN COIL UNIT. REFER TO MECHANICAL EQUIPMENT CONNECTION CHART
FOR DETAILS.
2-12, 1-12G, 3/4"C. TO FAN COIL UNIT THROUGH MAPA PEDESTAL.
2-12, 1-12G, 3/4"C. TO CONDENSING UNIT THROUGH MAPA PEDESTAL.
CONNECT TO RECEPTACLE PROVIDED WITH PEDESTAL. REFER TO CORRESPONDING
CONDENSING UNIT IN MECHANICAL EQUIPMENT CONNECTION CHART FOR DETAILS.
CONNECT TO BOILER. REFER TO MECHANICAL EQUIPMENT CONNECTION CHART FOR
DETAILS.
CONNECT TO BOILER PUMP. REFER TO MECHANICAL EQUIPMENT CONNECTION CHART
FOR DETAILS. INTERLOCK PUMP WITH "BOILER PUMP" RELAY IN BOILER 27-1.
COORDINATE DETAILS WITH EQUIPMENT PROVIDED.
CONNECT TO BOILER PUMP. REFER TO MECHANICAL EQUIPMENT CONNECTION CHART
FOR DETAILS. INTERLOCK PUMP WITH "BOILER PUMP" RELAY IN BOILER 27-2.
COORDINATE DETAILS WITH EQUIPMENT PROVIDED.
CONNECT TO HEATING WATER PUMP. REFER TO MECHANICAL EQUIPMENT
CONNECTION CHART FOR DETAILS. PROVIDE AND INSTALL A 120VAC 30A RELAY WITH A
24VAC COIL AT PUMP TO ALLOW FOR PUMP CONTROL VIA EMS SYSTEM. COORDINATE
DETAILS WITH THE CONTROLS CONTRACTOR.
CONNECT TO UNIT HEATER. REFER TO MECHANICAL EQUIPMENT CONNECTION CHART
FOR DETAILS.
CONNECT TO EXHAUST FAN. REFER TO MECHANICAL EQUIPMENT CONNECTION CHART
FOR DETAILS. PROVIDE AND INSTALL A 120VAC 20A RELAY WITH A 120VAC COIL AT FAN
TO ALLOW FOR FAN CONTROL VIA EMS SYSTEM. COORDINATE DETAILS WITH THE
CONTROLS CONTRACTOR.
CONNECT TO EXHAUST FAN. REFER TO MECHANICAL EQUIPMENT CONNECTION CHART
FOR DETAILS.
DEDICATED RECEPTACLE FOR WATER HEATER. REFER TO MECHANICAL EQUIPMENT
CONNECTION CHART FOR DETAILS.
CONNECT TO CIRCULATION PUMP. REFER TO MECHANICAL EQUIPMENT CONNECTION
CHART FOR DETAILS.
CONNECT TO WATER SOFTENER. REFER TO MECHANICAL EQUIPMENT CONNECTION
CHART FOR DETAILS.
DEDICATED RECEPTACLE FOR MIOX MAIN CONTROLLER. COORDINATE EXACT
MOUNTING LOCATION WITH EQUIPMENT PROVIDED. HOMERUN 2-12, 1-12G, 3/4"C.
DEDICATED RECEPTACLE FOR MIOX OXIDANT TANK LEVEL SENSOR. COORDINATE
EXACT MOUNTING LOCATION WITH EQUIPMENT PROVIDED. HOMERUN 2-12, 1-12G,
3/4"C.
DEDICATED RECEPTACLE FOR REVERSE OSMOSIS SKID. COORDINATE EXACT
MOUNTING LOCATION WITH EQUIPMENT PROVIDED. HOMERUN 2-12, 1-12G, 3/4"C.
DEDICATED RECEPTACLE FOR EMS CONTROL PANEL. COORDINATE EXACT MOUNTING
LOCATION WITH EQUIPMENT PROVIDED. HOMERUN 2-12, 1-12G, 3/4"C.
NO SCALE
KEYPLAN
COTTAGE BLDG. 27 -
EQUIPMENT POWER
FLOOR PLAN
SCALE: 1/4" = 1'-0"
D
B
G
HEA
C
F
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
23 RESIDENT
ROOM
TOIL.
TOIL.
TOIL.
CLEAN
SOILED
CORR.
TOIL.
RESIDENT
ROOM
SOILED
UTIL.
SPA/BATH/SAFE
ROOM
39SAFE
ROOM
LAUNDRY/
CORR.
RESIDENT
ROOM
TOIL.
LAUNDRY
H.A.C.
CORR.
45 MEDS
GUEST
TOIL.
CORR.
CLEAN
42TOIL.
RESIDENT
ROOM
1 RESIDENT
ROOM
TOIL.
TOIL.
SOILED
RESIDENT
ROOM
RESIDENT
ROOM
TOIL.
STAFF
OFFICE
FOYER
RECEIVING/STORAGE
CORR.
PANTRY
LIVING
ROOM
KITCHEN
MECHANICAL
STOR.
19B
DATA
ELEC.
DINING
ROOM
TOIL.
AHU 27-1
CEF 27-10
CEF 27-4
CEF 27-7
CEF 27-8CEF 27-9
CEF 27-3 CEF 27-2
CEF 27-1
CEF 27-5
CEF 27-6
EF 27-2
EF 27-1
S
S
S
HW
P
-1
HW
P
-2
BOILER 27-2
BOILER 27-1
UH-27-1
CU 27-1
CU 27-2
MIOX 27-1 WS 27-1WH 27-1
J
C4M-1,3,5
J C4M-13,15,17
J C4M-19,21,23
FC 27-A
JJJ
CU 27-A
J
C4M-2,4 C4M-29
J
J
C4M-6
C4M-8
JC4M-10
BP 27-1
J C4M-12
BP 27-2
J J
C4M-14
C4M-16
J C4M-18
J R
C4M-20
J R
C4M-22
J
C4M-24
J
C4M-26
J
C4M-28J
C4M-30
J C4M-32
J C4M-34
J
C4M-42 J C4M-36
J
C4M-40
J
C4M-38
GFI GFI GFI
C4 M-
C4
M-
C4 M-
18 19
J C4M-46
16 CP 27-1
JC4M-31
GFI
C4M-48
SUPPLIES/EQUIP.
STOR.
STORAGE
18A
STORAGE
11A
S
S
S
S
S
SS
S
S
S
S
S
S S
S
S
C4M-33
BID DOCUMENTS SUBMISSION
27-E3.0 1/4" = 1'-0"1
LIGHTING FLOOR PLAN -
COTTAGE BUILDING #27
27-E3.0.dwg
BUILDING
N.I.C.
N.I.C.
N.I.C.
BUILDING
1 CONNECT EMERGENCY DRIVER OF THE FIXTURE TO THE UNSWITCHED HOT
CONDUCTOR OF THE CIRCUIT. FIXTURE SHALL BE SWITCHED AND EMERGENCY
DRIVER SHALL ONLY BE ACTIVE IF CIRCUIT IS DE-ENERGIZED.
CHAIN HUNG FIXTURE(S) MOUNTED 9'-0" AFF.
MOUNT FIXTURE ON WALL ABOVE DOOR.
MOUNT FIXTURE ON WALL ABOVE MIRROR.
PANEL C4 (3-SECTION).
LIGHTING CONTROL PANEL LCP.
HOMERUN THROUGH LIGHTING CONTROL PANEL LCP.
MOUNT FIXTURE ON WALL APPROX. 8'-0" AFF. VERIFY EXACT MOUNTING LOCATION
WITH ARCHITECTURAL.
EGRESS FIXTURE ONLY AND EMERGENCY DRIVER SHALL ONLY BE ACTIVE IF CIRCUIT IS
DE-ENERGIZED.
PROVIDE A TWO BUTTON SWITCH STATION FOR THE LIGHTING CONTROL SYSTEM
EQUAL TO A HUBBELL LVSM1NP (WHITE COLOR) FOR LOCAL CONTROL OF
DINING/KITCHEN/LIVING/CORRIDOR/FOYER LIGHTS. TOP BUTTON SHALL CONTROL THE
DINING/KITCHEN/LIVING…