Atch 5 Drawing Armstrong AFH 4100 J Condensate Pump 30GAL Duplex.pdf
PDF 262 KB Posted
- Attached to
- Z1DA--626-24-204 - Update / Upgrade Steam System Components Federal contract opportunity
- Solicitation number
- 36C24924B0011
About this file
This document is a Statement of Work (SOW) for a federal contract opportunity to upgrade the steam system components at the Tennessee Valley Healthcare System (TVHS) Nashville Campus. The key objectives include replacing failing condensate return skid pumps, piping, and associated components, as well as adding venting as specified in the attached drawings.
The scope of work includes replacing various steam traps, separating mixed pressure condensate return lines, installing new condensate return skid pumps, replacing flash tanks and pumping systems, and correcting piping issues throughout the facility. The contractor will be responsible for all work to provide an acceptable final product that meets the requirements outlined in the SOW and drawings. The period of performance is 120 calendar days from the notice to proceed, and the contract will result in a single award.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
3.13
6.56 11.00
21.06 22.00
LIFTING EYES
(OPTIONAL)
THERMOMETER
(OPTIONAL)
1/2" NPT
DRAIN
11.00
9.00
18.00
2" NPT VENT
1-1/2" NPT
PUMP
DISCHARGE
PRESSURE GAUGE, CHECK VALVE
GATE VALVE AND BALL VALVE
(OPTIONAL)
4.50 9.00
.25
FOOT PAD
16.00
22.00 32.78
47.24
3.38
2" NPT
OVERFLOW
2-1/2" NPT
PROCESS RETURN
PRESSURE GAUGE, CHECK VALVE
GATE VALVE AND BALL VALVE
(OPTIONAL)
CONTROL PANEL OPTIONS ALSO AVAILABLE (NOT SHOWN):
• NEMA 4 OR NEMA 4X OR NEMA 3R CONSTRUCTION
• ELECTRIC ALTERNATOR
• POWER ON LIGHT
• PUMP TEST BUTTON
• PUMP RUN TIME METER
• EXTRA DRY CONTACTS
• UL/CUL LABELED PANEL
• HIGH LEVEL ALARM HORN & LIGHT W/SILENCE SWITCH
• LEAD-AUTO-LAG SELECTOR SWITCH
NOTES:
• TANK MATERIAL: STEEL
• ALL DIMENSIONS ARE ±0.25"
• DRAWING NOT FOR CONSTRUCTION
• CONSULT FACTORY AT TIME OF ORDER FOR CURRENT PRINT
• INLET BASKET STRAINER OR Y-STRAINER ALSO AVAILABLE
18.25
39.44
9.00
10.75
NEMA 12
CONTROL PANEL
(OPTIONAL)
ISOLATION VALVE
(OPTIONAL)
FLOAT SWITCH OR
ALTERNATOR
GAUGE GLASS
(OPTIONAL)
D
C
B
A A
B
C
D
12345678
8 7 6 5 4 3 2 1
THIRD ANGLE PROJECTION
SCALE: 1:12SHEET: 1 OF 1 A684.41030.00J
4/12/2018
NAME DATE
ENG APPR.
CHECKED
DRAWN
30 GALLON DUPLEX
PART NO:
GJM
Ref PartNo
TITLE
DWG NO. REV
4100 SERIES
"J" CONDENSATE PUMP
DRAWING MAY NOT BE PRINTED TO SCALE.
DATENAME
4/12/2018GJMA
REV DESCRIPTION ECN
Initial Design
WEIGHT
356.39
FABRICATION TOLERANCES
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES
TOLERANCES:
ANGULAR DIMENSIONS 1
FRACTIONS 1/32
TWO PLACE DECIMAL 0.06
THREE PLACE DECIMAL 0.030 PRODUCT CATEGORY
HTSP Boiler and Condensate
PRODUCT FAMILY
armstronginternational.com
| Sheet1 |
| Drawing View1 |
| Drawing View2 |
| Drawing View3 |
| Drawing View4 |
| Drawing View5 |
File details come from the government source that posted it. Updated .