Atch 4_Elevator Asbestos Rpt.pdf

PDF 153 KB Posted

Attached to
VTE Elevator Maintenance Services at Whiteman AFB Federal contract opportunity
Solicitation number
FA462525Q1004
Issued by
Department of the Air Force Global Strike Command

About this file

The document is an Elevator Maintenance Asbestos Report dated 5/22/2018, providing an inventory of asbestos presence across multiple buildings. The report details specific findings for 11 buildings, including:

Significant asbestos-related observations include: Building 41 has asbestos-wrapped steam pipe insulation in the mechanical room with no removal records; Building 709 contains grey insulation board with asbestos in room #122 and previously had asbestos under the steel floor in room #126c; Building 50 has a letter indicating no asbestos is present; Buildings 1230 and 3200 had sampling conducted with negative asbestos results. Several buildings (139, 153, 157, 509, 515, and 2005) have no records on file regarding asbestos presence.

View the file

Other files for this federal contract opportunity

Other files attached to VTE Elevator Maintenance Services at Whiteman AFB, newest first.
File Type Posted
Atch 1_VTE PWS Rev1 22Jul2025.pdf PDF
Atch 2_Bid Schedule 25Q1004 Rev1 21Jul2025.xlsx XLSX spreadsheet
25Q1004 VTE Elevator Mx Vendor Questions and Answers.pdf PDF
Atch 3_WD 1986-0497 Rev 59 dtd 12Feb2025.pdf PDF
Atch 5_VTE Location Map.pdf PDF
VTE Combo 25Q1004.pdf PDF
Atch 6_Past Performance Questionnaire.docx DOCX document
Atch 7_Provisions and Clauses.pdf PDF
Atch 2_Bid Schedule 25Q1004.xlsx XLSX spreadsheet
Atch 1_VTE PWS 30 Apr 2025.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Elevator Maintenance Asbestos Report 5/22/2018

Bldg 41: records show asbestos wrapped steam pipe insulation in mechanical room, no records that show it has been removed.

Bldg 50: have a letter in the records that indicate no asbestos found to be present.

Bldg 139: no records on this facility.

Bldg 153: no records on this facility.

Bldg 157: no records on this facility.

Bldg 509: no records on this facility.

Bldg 515: no records on this facility

Bldg 709: grey insulation board in room #122 contains asbestos, no records showing it has been removed. Also asbestos under steel floor in room #126c, has been removed. No other records on this facility.

Bldg 1230: pipe insulation in tunnel sampled and found to be negative for asbestos, no other records for the facility.

Bldg 2005: no records on this facility.

Bldg 3200: walk-through was conducted and numerous samples taken and all were negative for asbestos