AS-BUILTS (FIO)_APSI Fuel Yokota.pdf
PDF 41 MB Posted
- Attached to
- Asia Pacific Stability Initiative (APSI) – Fuel Receipt and Distribution Upgrades Yokota
- Solicitation number
- W912HV21R0001
About this file
This solicitation seeks proposals for upgrades to the liquid fuel unloading and distribution facility at Yokota Air Base in Japan. The Asia Pacific Stability Initiative (APSI) - Fuel Receipt and Distribution Upgrades Yokota project aims to expand and upgrade the existing facility to accommodate rail cars and fuel delivery trucks, comply with current requirements, and ensure a complete and usable system. Specifically, the project includes replacing rail station headers and adding truck offload headers, installing two drop tanks in below-ground vaults with pumps and piping, upgrading the backup generator, adding secondary containment and a remote spill containment basin, constructing truck access roads and an offload parking area, and improving on-base roads. Nearby lighting, utilities, yard piping, rail lines and other components will also be replaced or improved. The solicitation was released by the Department of the Army Corps of Engineers Engineering District Japan.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIO (FOR INFORMATION ONLY)
j2ee9gsg Text Box "As-Built" drawings are provided for informational purposes only (FIO). These "As-built" drawings are not part of the solicitation (and will not become part of the contract) and do not amend the solicitation (specifications, drawings, etc.). "As-builts" drawings may not be complete or depict existing conditions. The contractor will be responsible for verifying actual conditions at the site.
| ds0188 spill containment |
| ds04840 B4091 piping and pumps |
| 00 COVER SHEET.tif |
| 01 C1 GENERAL SITE PLAN.tif |
| 02 C2 DETAIL SITE PLAN.tif |
| 03 A1 FLOOR PLAN, ELEV & SECTION.tif |
| 04 A2 WALL SECTION & MISC DETAIL.tif |
| 05 S1 STRUCTURE PLAN.tif |
| 06 M1 LAYOUT & KEY PLAN.tif |
| 07 M2 PIPING PLAN 1.tif |
| 08 M3 PIPING PLAN 2.tif |
| 09 M4 PIPING PLAN 3.tif |
| 10 M5 PIPING PROFILE.tif |
| 11 M6 STAND-BY GENERATOR & DETAIL.tif |
| 12 M7 MISC DETAIL.tif |
| 13 E1 ELEC DISTRIBUTION PLAN.tif |
| 14 E2 ELEC PLAN & DIAGRAM.tif |
| ds05336 B4091 transformers |
| E01(目次) |
| T01(表紙) |
| E02(B1390平面図) |
| E03(B1390姿図) |
| E04(B4070平面図) |
| E05B4070姿図) |
| E06(B4085平面図) |
| E07(B4091姿図) |
| E08(B4091平面図) |
| E09(B4091姿図) |
| ds05379 leak detection |
| 01 |
| 02 |
| 03 |
| 04 |
| 05 |
| 06 |
| 07 |
| 08 |
| 09 |
| 10 |
| ds05381 liquid fuel stands |
| 01 |
| 02 |
| 03 |
| 04 |
| 05 |
| 06 |
| 07 |
| ds06600 B4091 outside air |
| ds07135 B4091 lighting and electrical |
| UNLOADING ELEC |
File details come from the government source that posted it. Updated .