Appendix H(m) - Building 1582 Hazardous Materials Report.pdf

PDF 14 MB Posted

Attached to
Demolition of Facilities Phase 6 Federal contract opportunity
Solicitation number
FA4819-20-R-1000
Issued by
Department of the Air Force Air Combat Command

About this file

This document contains a pre-demolition survey report for Building 1582 at Tyndall Air Force Base in Florida. The report identifies asbestos-containing materials found in the building and evaluates waste streams, regulated materials, and soil samples prior to the planned demolition. Asbestos was found in multiple materials including floor tiles, ceiling tiles, mastic, and roofing materials. Toxicity Characteristic Leaching Procedure tests were performed on waste streams and detected no hazardous metals above regulatory thresholds. Polychlorinated biphenyls and organochlorine pesticides were not detected in any samples. The report provides conclusions and recommendations for asbestos abatement and handling of regulated materials during demolition in accordance with applicable regulations and standards.

View the file

Other files for this federal contract opportunity

Other files attached to Demolition of Facilities Phase 6, newest first.
File Type Posted
Late Questions and Answers.xlsx XLSX spreadsheet
Questions and Answers.xlsx XLSX spreadsheet
Appendix I Monitoring Wells.pdf PDF
Questions and Answers.xlsx XLSX spreadsheet
RFQ 20R1000 Demo Facilities Phase VI.pdf PDF
Appendix C Phase 6 Notes Per Bldg.xlsx XLSX spreadsheet
PWS Demolition Phase 6 - 12 May 2020.pdf PDF
422.pdf PDF
Appendix A Phase 6 Map.pdf PDF
Appendix B Abandoned Utilties.pdf PDF
Appendix H(g) - Building 188 Hazardous Materials Report.pdf PDF
RFQ 20R1000 Demo Facilities Phase VI.pdf PDF
Appendix F Draft Surveys.pdf PDF
Appendix D(e) Photos.pdf PDF
Appendix H(i) - Building 509 Hazardous Materials Report.pdf PDF
Appendix H(a) - Asbestos Reports.pdf PDF
Appendix H(d) - Building 162 Hazardous Materials Report.pdf PDF
Appendix A Phase 6 Map.pdf PDF
Appendix B Abandoned Utilties.pdf PDF
Appendix C Phase 6 Notes Per Bldg.xlsx XLSX spreadsheet
Appendix H(f) - Building 179 Hazardous Materials Report.pdf PDF
Appendix D(d) Photos.pdf PDF
Appendix D(a) Photos.pdf PDF
Appendix H(k) - Building 960 Hazardous Materials Report.pdf PDF
Appendix H(e) - Building 164 Hazardous Materials Report.pdf PDF
Appendix D(b) Photos.pdf PDF
Appendix H(c) - Building 108 Hazardous Materials Report.pdf PDF
Appendix H(b) - Building 107 Hazardous Materials Report.pdf PDF
Appendix H(j) - Building 526 Hazardous Materials Report.pdf PDF
Appendix H(l) - Building 1506 Hazardous Materials Report.pdf PDF
Appendix H(h) - Building 504 Hazardous Materials Report.pdf PDF
PWS Demolition Phase 6.pdf PDF
Appendix G MOA Between 325CES_GCEC.pdf PDF
Appendix D(c) Photos.pdf PDF
Wage Determination FL 20200105.pdf PDF
Appendix E Drawings.pdf PDF
Appendix D(f) Photos.pdf PDF
Show all 37

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TYNDALL AFB PRE-DEMOLITION SURVEY

W912DY-19-P-0053

Pre-Demolition Report for Asbestos, Hazardous Materials & Soil Testing

For:

Facilities Reduction Program FY19 Tyndall II

Tyndall AFB, Florida Building 1582 VAQ Dorm

Prepared For:

US Army Corps of Engineers

Engineering & Support Service Center 4910 University Square, Suite 4

Huntsville, Alabama 35816-1822 Facilities Reduction Program

ATTN: CEHNC-ISF

March 2020

AQ#: 15671

ii

CERTIFICATION PAGE

Pre-Demolition Report for Asbestos, Hazardous Materials & Soils Testing

Facilities Reduction Program FY19 Tyndall II Tyndall Air Force Base, Florida

Building 1582 VAQ Dorm

AirQuest Project #15671

Prepared For:

US Army Corps of Engineers Engineering & Support Service Center

4910 University Square, Suite 4 Huntsville, Alabama 35816-1822

ATTN: CEHNC-ISF

Prepared By:

AirQuest Environmental, Inc.

6851 Southwest 45th Street

Fort Lauderdale, Florida 33314

Adrian Amicucci Traci-Anne Boyle, CIH, CSP Asbestos Building Inspector FL Asbestos Consultant #AX-60

Ted Smith, PG

FL Professional Geologist No. PG1368 iii

TABLE OF CONTENTS

PAGE

1 INTRODUCTION AND SITE DESCRIPTION 1

1.1 PURPOSE 1

1.2 SITE DESCRIPTION 1

1.3 DEMOLITION OVERVIEW 1

2 ASBESTOS SURVEY 2

2.1 SURVEY METHODS 2

2.2 LABORATORY ANALYSIS 2

2.3 SUSPECT ASBESTOS-CONTAINING MATERIALS 3

3 LEAD BASED PAINT SCREENING 7

4 TCLP RCRA METALS 7

4.1 TCLP SAMPLE COLLECTION 8

4.2 TCLP SAMPLE RESULTS 8

5 PCBS 8

6 OTHER REGULATED MATERIALS INVENTORY 9

7 SOIL TESTING FOR ORGANOCHLORINE PESTICIDES 13

8 CONCLUSIONS AND RECOMMENDATIONS 13

8.1 ASBESTOS CONCLUSIONS AND RECOMMENDED RESPONSE ACTION 13

8.2 LEAD SCREENING & OSHA LEAD GUIDANCE 13

8.3 TCLP RCRA METALS / LEAD 13

8.4 PCBS 13

8.5 OTHER REGULATED MATERIALS 13

8.6 SOIL CONCLUSIONS 13

9 LIMITATIONS 13

iv

TABLES

Table 1 – Survey Information Table 2 – Asbestos Laboratory Analysis and Summary Table 3 - Lead Based Paint Screening Information Table 4 - Waste Stream Composition Table 5 – Toxicity Characteristic Leachate Procedure Results Table 6 – PCB Results Table 7 – Other Regulated Materials Inventory Table 8 – Soil Sample Analytical Results

APPENDICES

Appendix I – Certifications

Appendix II – Sample Location Diagrams

Appendix III – Structure Demolition Overview (Diagram, Aerial Photographs, Photographs)

Appendix IV – Asbestos Laboratory Report and Chain of Custody Record

Appendix V – Suspect Asbestos Containing Material Photographs

Appendix VI – TCLP Laboratory Report and Chain of Custody Record

Appendix VII – PCB Laboratory Report and Chain of Custody Record

Appendix VIII – Soil Boring Logs and Soil Boring Location Photographs

Appendix IX – Soil Laboratory Report and Chain of Custody Record

AirQuest Environmental, Inc.

AirQuest Project #15671 1 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing

1 INTRODUCTION AND SITE DESCRIPTION

In accordance with the Performance Work Statement (PWS) for contract W912DY-19-P-0053, AirQuest Environmental, Inc. (“AirQuest”) performed pre-demolition asbestos, hazardous materials, and soil testing for Building 1582 located at Tyndall Air Force Base, Florida (“the site”).

The surveys were performed by AirQuest Project Team Members as shown in Table 1. Copies of applicable licenses and accreditations are included in Appendix I.

Table 1 – Survey Information

Survey Name Survey Date

Asbestos Adrian Amicucci 04 December 2019

TCLP Waste Stream Travis Holland 04 December 2019

PCB Waste Stream Travis Holland 04 December 2019

Other Regulated Materials Melissa Suarez 04 December 2019

Soil Sample Collection Ted Smith 26 November 2019

TCLP – Toxicity Characteristic Leachate Procedure PCB – Polychlorinated Biphenyl

1.1 PURPOSE

The purpose of this survey was to identify asbestos-containing materials (ACM) within the interior, exterior and roof of the building; to determine if Other Regulated Materials (ORM) materials were present; to complete a waste stream analysis for Toxicity Characteristic Leachate Procedure (TCLP) Resource Conservation and Recovery Act (RCRA)-8 metals and Polychlorinated Biphenyls (PCBs); and to collect soil samples for organochlorine pesticides (OCP) for each structure. Diagrams depicting sampling locations are provided in Appendix II.

The investigation was conducted to facilitate the repairs at Tyndall Air Force Base following Hurricane Michael.

1.2 SITE DESCRIPTION

Building 1582 VAQ Dorm was a 6,422 square foot, single-story structure built in 1943. The building was constructed of concrete block on a concrete slab foundation and finished with exterior stucco. The roof deck was constructed with wood and finished with asphalt shingles. The ceilings were constructed of acoustic ceiling tiles and drywall system. Interior walls were constructed of drywall system and select areas were finished with ceramic tiles. The concrete floor was finished with carpet, vinyl floor tiles and ceramic tiles.

1.3 DEMOLITION OVERVIEW

A diagram illustrating the general layout of the site was prepared using files provided by the client if available or drawn onsite by the AirQuest inspector. AirQuest prepared aerial photographs and photographed an overview of the interior and exterior of the building for purposes of assisting

AirQuest Project #15671 2 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing contractors in evaluation of the demolition requirements. The diagram and photographs are included in Appendix III.

2 ASBESTOS SURVEY

A pre-demolition asbestos survey suitable to meet the requirements of the National Emissions Standard for Hazardous Air Pollutants (NESHAPs) and State of Florida regulations was performed at the site.

2.1 SURVEY METHODS

The sampling protocol used generally followed Asbestos Hazard Emergency Response Act (AHERA) guidelines. AHERA was promulgated by the United States Environmental Protection Agency (EPA) in 1987 and regulated public schools.

Suspect materials were differentiated into three categories: surfacing material, thermal system insulation, or miscellaneous material. Surfacing material is anything that is sprayed or troweled onto a surface; thermal system insulation is material used to insulate HVAC pipes, tanks, etc., and miscellaneous material is any other type of material.

A homogeneous area is defined as an area of surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color and texture. A homogeneous area is not limited to only a room but can be found in several rooms. Sample selection in the building was determined by identifying the homogeneous areas and basing sampling locations upon these areas.

In conducting the building inspection in compliance with local, state, and federal regulations, all suspected ACM which were accessible to the inspector, were either sampled to confirm the actual presence of asbestos or assumed to contain asbestos.

2.2 LABORATORY ANALYSIS

Analysis was performed using Polarized Light Microscopy (PLM) with dispersion staining. The laboratory is rated proficient through National Institute of Standards and Technology- National Voluntary Laboratory Accreditation Program (NIST-NVLAP) for bulk asbestos analysis.

NESHAP defines ACM as containing more than 1% asbestos as determined using PLM (as specified in Appendix E, Subpart E, 40 CFR part 763, Section 1, Polarized Light Microscopy).

NESHAP defines friable ACM as any material containing more than 1% asbestos that, when dry, can be crumbled, pulverized or reduced to a powder by hand pressure. If the asbestos content of a friable material is less than ten (10) percent as determined by a method other than point counting by PLM, the client may elect to verify the asbestos content by point counting using PLM.

Because of the inherent limitations of PLM bulk sample analysis, any friable sample reported as <2% asbestos by PLM was automatically analyzed by the PLM point count method to determine whether it may be regulated under the asbestos NESHAP.

AirQuest Project #15671 3 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing

Estimates of quantities of ACM were based upon the identification of suspect materials. Where suspect ACM were located behind walls, above ceilings, beneath carpeting, or other concealed conditions and the quantities cannot be verified, the estimate is based upon the conditions present during the survey. These estimates are not to be considered absolute and should be verified when the ACM is exposed.

2.3 SUSPECT ASBESTOS-CONTAINING MATERIALS

Homogenous areas (HA) of suspect material were identified and samples were collected and submitted under chain of custody to EMSL Analytical, Inc. (“EMSL”) for laboratory analysis of asbestos by PLM. If identified, friable samples with <2% asbestos were further analyzed by the PLM point count method to confirm the PLM results. A copy of the laboratory report and chain of custody record is included in Appendix IV.

Sample descriptions and laboratory results are summarized in Table 2. Photographs of each HA are included in Appendix V.

Table 2 – Asbestos Laboratory Analysis and Summary

HA Sample Number

Description of Suspect Material

Location Asbestos Content %

1 1582-1 Drywall System – Wall 15 North ND

1 1582-2 Drywall System – Wall 14 South ND

1 1582-3 Drywall System – Wall 19 West ND

1 1582-4 Drywall System – Wall 20 North ND

1 1582-5 Drywall System – Wall 12 South ND

1 1582-6 Drywall System – Wall 12 Southwest ND

1 1582-7 Drywall System – Wall 10 South ND

2 1582-8 12” x 12” White ACT Dot- Dash – Ceiling 12 Center ND

2 1582-9 12” x 12” White ACT Dot- Dash – Ceiling 14 Center ND

2 1582-10 12” x 12” White ACT Dot- Dash – Ceiling 15 Center ND

2 1582-11 12” x 12” White ACT Dot- Dash – Ceiling 21 Center ND

2 1582-12 12” x 12” White ACT Dot- Dash – Ceiling 20 Center ND

3 1582-13 4” x 4” Ceramic Tile – Wall 16 North ND

AirQuest Project #15671 4 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing

HA Sample Number

Description of Suspect Material

Location Asbestos Content %

3 1582-14 4” x 4” Ceramic Tile – Wall 18 North ND

3 1582-15 4” x 4” Ceramic Tile – Wall 24 South ND

4 1582-16 6” x 6” White Ceramic Tile – Floor 15 East ND

4 1582-17 6” x 6” White Ceramic Tile – Floor 18 East ND

5 1582-18 White Carpet Mastic – Floor 20 Northwest ND

5 1582-19 White Carpet Mastic – Floor 22 Southwest ND

5 1582-20 White Carpet Mastic – Floor 14 Northeast ND

6 1582-21 Interior Concrete Slab – Floor 12 East ND

6 1582-22 Interior Concrete Slab – Floor 12 North ND

6 1582-23 Interior Concrete Slab – Floor 1 South ND

6 1582-24 Interior Concrete Slab – Floor 13 East ND

6 1582-25 Interior Concrete Slab – Floor 13 West ND

7 1582-26 Exterior Concrete Slab – Floor Exterior North ND

7 1582-27 Exterior Concrete Slab – Floor Exterior West ND

7 1582-28 Exterior Concrete Slab – Floor Exterior Southwest ND

8 1582-29 Exterior Epoxy Floor Exterior North ND

8 1582-30 Exterior Epoxy Floor Exterior West ND

8 1582-31 Exterior Epoxy Floor Exterior Northwest ND

9 1582-32 Exterior Floor Expansion Material Exterior Southwest ND

9 1582-33 Exterior Floor Expansion Material Exterior North ND

10 1582-34 6” x 6” Red Ceramic Tile – Floor Exterior South ND

AirQuest Project #15671 5 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing

HA Sample Number

Description of Suspect Material

Location Asbestos Content %

10 1582-35 6” x 6” Red Ceramic Tile – Floor Exterior North ND

11 1582-36 12” x 12” Beige Vinyl Floor Tile 10 East ND

11 1582-37 12” x 12” Beige Vinyl Floor Tile 10 West ND

12 1582-38 4” White Vinyl Base Cove 10 North ND

12 1582-39 4” White Vinyl Base Cove 12 North ND

13 1582-40 White Interior Door Caulk 15 West ND

13 1582-41 White Interior Door Caulk 12 West ND

13 1582-42 White Interior Door Caulk 21 West ND

14 1582-43 White Sink Undercoating 15 East ND

14 1582-44 White Sink Undercoating 20 North ND

15 1582-45 Gray Sink Undercoating 12 South ND

15 1582-46 Gray Sink Undercoating 12 South ND

16 1582-47 Gray Electrical Putty 13 Southeast ND

16 1582-48 Gray Electrical Putty 13 Southeast ND

17 1582-49 Asphalt Shingle Deck – Roof Roof Southwest ND

17 1582-50 Asphalt Shingle Deck – Roof Roof South ND

17 1582-51 Asphalt Shingle Deck – Roof Roof East ND

17 1582-52 Asphalt Shingle Deck – Roof Roof North ND

17 1582-53 Asphalt Shingle Deck – Roof Roof Northeast ND

18 1582-54 Red Fire Caulk 13 Southeast ND

18 1582-55 Red Fire Caulk 13 Southeast ND

AirQuest Project #15671 6 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing

HA Sample Number

Description of Suspect Material

Location Asbestos Content %

19 1582-56 Black Curb Vent Mastic – Roof Roof North ND

19 1582-57 Black Curb Vent Mastic – Roof Roof Center ND

19 1582-58 Black Curb Vent Mastic – Roof Roof South ND

20 1582-59 Black Penetration Mastic – Roof Roof North ND

20 1582-60 Black Penetration Mastic – Roof Roof Center ND

20 1582-61 Black Penetration Mastic – Roof Roof South ND

21 1582-62 Black Penetration Mastic at Gable – Roof Roof North ND

21 1582-63 Black Penetration Mastic at Gable – Roof Roof Northwest ND

22 1582-64 Exterior Stucco – Wall Exterior West ND

22 1582-65 Exterior Stucco – Wall Exterior Southwest ND

22 1582-66 Exterior Stucco – Wall Exterior South ND

22 1582-67 Exterior Stucco – Wall Exterior East ND

22 1582-68 Exterior Stucco – Wall Exterior Northeast ND

23 1582-69 Exterior Stucco Patch – Wall Exterior North ND

23 1582-70 Exterior Stucco Patch – Wall Exterior East ND

23 1582-71 Exterior Stucco Patch – Wall Exterior Southeast ND

24 1582-72 White Exterior Caulking at Mechanical Room Window Exterior West ND

24 1582-73 White Exterior Caulking at Mechanical Room Window Exterior West ND

25 1582-74 White Interior Wall Expansion Caulk 13 Southeast ND

25 1582-75 White Interior Wall Expansion Caulk 13 Southeast ND

26 1582-76 Drywall System – Ceiling 13 Southeast ND

AirQuest Project #15671 7 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing

HA Sample Number

Description of Suspect Material

Location Asbestos Content %

26 1582-77 Drywall System – Ceiling 13 North ND HA- Homogenous Area ND – None Detected ACT- Acoustical Ceiling Tile

3 LEAD BASED PAINT SCREENING

An inspection was conducted to screen for the existence of lead containing painted building components. Testing of the painted building components was performed using an XRF Spectrometer. The XRF is a screening instrument currently recommended by the US Department of Housing and Urban Development (HUD) for analysis of lead levels in paint. The screening was used to assist in determining the need and relative concentrations of lead on painted building components for purposes of designing a sampling scheme for a composite waste stream analysis and demolition contractor worker protection information. The screening was not intended to be a lead-based paint survey in accordance with HUD guidelines. A summary of the screening results is included in Table 3.

Table 3 - Lead Based Paint Screening Information

Structure Color Substrate Location Results1 Pb (mg/cm2)

Wall White Drywall Bedroom Negative 0.1 Wall White Drywall Bedroom Negative 0.2 Wall White Drywall Kitchen Negative 0.1 Wall White Drywall Kitchen Negative -0.2 Wall White Drywall Living Room Negative 0.1 Wall Beige Concrete Exterior Positive 1.4 Wall Beige Concrete Exterior Positive 1.6 Wall Beige Concrete Exterior Negative 0.1 Wall Beige Concrete Exterior Negative -0.2 Door Brown Metal Exterior Negative 0.1

Pb - Lead mg/cm2 – milligrams per square centimeter 1Indicates if the material meets the Department of Housing and Urban Development definition of Lead Based Paint

4 TCLP RCRA METALS

A waste stream composite sample was collected from the building for laboratory analysis of TCLP RCRA-8 Metals.

AirQuest Project #15671 8 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing

4.1 TCLP SAMPLE COLLECTION

The sample composition was determined by the composition of the materials comprising the building. Each major building component (such as wood, metal, concrete, glass, etc.) was estimated as a percentage of the weight of the building whole. Once the composition of the building was estimated, representative samples were collected of each material, in an approximate weight proportion as shown in Table 4.

Table 4 - Waste Stream Composition

Waste Stream Component Percentage of

Waste Concrete 60

Metal 10 Wood 10

Drywall 10 Miscellaneous 10

Total Percentage 100

4.2 TCLP SAMPLE RESULTS

The samples were submitted under chain of custody to Spectrum Environmental Laboratories (“Spectrum”), a National Environmental Laboratory Accreditation Conference (NELAC) accredited laboratory, for analysis of TCLP-RCRA-8 Metals by EPA via 1311/6010C/7470A. The results are summarized in Table 5.

Table 5 – Toxicity Characteristic Leachate Procedure Results

Sample TCLP Results (milligrams/liter)

Arsenic Barium Cadmium Chromium Lead Mercury Selenium Silver 1582-

ND 0.198 ND ND 0.055 ND ND ND

Limit1 5.0 100.0 1.0 5.0 5.0 0.2 1.0 5.0 1Regulatory Limit per 40 CFR 261.24 ND – None Detected

5 PCBs Samples for PCBs were collected in general accordance with the EPA Region 1 Standard Operating Procedure for Sampling Porous Surfaces for Polychlorinated Biphenyls (PCBs), May 2011.

The samples were collected from representative painted surfaces to include up to a half-inch of the substrate. The samples were submitted under chain of custody to Spectrum for analysis by EPA Method SW 846 3540C/8020A.

AirQuest Project #15671 9 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing

Table 6 – PCB Results

Sample Results (mg/kg)

Aroclor-

Aroclor-

Aroclor-

Aroclor-

Aroclor-

Aroclor-

Aroclor-

PCB-1582-001

Concrete

ND ND ND ND ND ND ND

PCB-1582-002

Paint

ND ND ND ND ND ND ND

1Regulatory Limit per 40 CFR 761.50 Subpart D is 50 mg/kg mg/kg – milligrams/kilogram ND – None Detected

6 OTHER REGULATED MATERIALS INVENTORY

AirQuest conducted another regulated/hazardous materials inventory in general accordance with the Recommended Management Practices for the Removal of Hazardous Materials from Buildings Prior to Demolition prepared by the University of Florida and sponsored by the Florida Department of Environmental Protection, 1999. The inventory included lamps, thermostats, and light switches potentially containing mercury; exit signs, emergency lights, and smoke alarms that have batteries; lighting ballasts which contain polychlorinated biphenyls (PCBs); transformers;

freon, hazardous chemicals and petroleum products; and lead pipes and roof vent flashings.

Certain assumptions for the inspection of fluorescent light ballasts for PCBs were utilized for the building inspections to be completed in a timely and cost-effective manner. As required by regulation, lighting ballasts must not contain PCBs and the label on the ballast must state “No PCB”. AirQuest inventoried 100% of the fluorescent lighting fixtures and inspected a representative of each type of fixture (i.e. 2-foot, 4-foot, etc.) for the “No PCB” labeling.

Each exit sign and emergency lights were presumed to each contain a single lead-acid rechargeable battery. Quantities and types of any ORM found are summarized in Table 7.

AirQuest Project #15671 10 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing

Table 7 – Other Regulated Materials Inventory

ORM Component Type/Location Quantity Photographs

Recyclables

Fluorescent Bulbs 48" Lamp 12

Fluorescent Bulbs Compact Bulbs 17

Fluorescent Bulbs Round Bulb 130

Light Ballasts In 48" Fluorescent Fixtures

AirQuest Project #15671 11 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing

ORM Component Type/Location Quantity Photographs

LED Bulbs 12

Printer & Toner 4

Fire Pull-Down System

Specialized ORM

Freon In A/C Units 22

AirQuest Project #15671 12 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing

ORM Component Type/Location Quantity Photographs

Freon Refrigerator Units 6

Transformers Exterior Pad Mounted

TECO Natural Gas Lines

Fire Extinguishers 3

AirQuest Project #15671 13 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing

7 SOIL TESTING FOR ORGANOCHLORINE PESTICIDES

AirQuest advanced four (4) soil borings and collected two (2) samples at each boring location at depths of zero to six inches (0 - 6 in.) and eighteen to twenty-four inches (18 – 24 in.) below land surface using a properly decontaminated hand bucket auger. The samples were generally collected near the four corners of the building as shown in Appendix II.

The soil sampling was conducted in accordance with Florida Department of Environmental Protection (FDEP) Standard Operating Procedures SOP-001-01 FS 3000 (Soil) and SOP-001-01 FQ1000 (Field Quality Control Requirements). One boring log was completed for each building location documenting the observed lithology, visually estimated moisture content, noticeable odors, soil color, sample collection times, sampler’s name, sampling interval and boring completion method. The soil boring log and soil boring location photographs are included in Appendix VIII.

Samples were placed in dedicated sample containers provided by the laboratory and labeled according to the referenced building/structure, collection time, sampler’s name and analysis. A chain of custody form was completed to document the chronology of ownership, control and transfer of the samples. All samples were placed in a cooler filled with ice for transfer to the laboratory.

The soil samples were shipped to Eurofins TestAmerica (“TestAmerica”) in Pensacola, Florida, a NELAC accredited environmental laboratory licensed in the State of Florida, for analysis by EPA Method: 8081B (Organochlorine Pesticides by GC). Analytical results are summarized in Table

8. A copy of the laboratory report and chain of custody record is included in Appendix IX.

The analytical results indicate there are traces of OCPs 4,4’-DDD, 4,4’-DDE, 4,4’-DDT, Dieldrin, and Total Chlordane above the laboratory method detection limit and some above the practical quantitation limit, in most of the soil samples. The detected concentrations do not exceed the Commercial/Industrial or Residential Soil Cleanup Target Levels (SCTLs) provided in Chapter 62-777, FAC, the criteria used by the FDEP.

8 CONCLUSIONS AND RECOMMENDATIONS

A thorough pre-demolition inspection for asbestos and hazardous materials was conducted at the site and an inventory of the materials was created. The soils surrounding the site were sampled and analyzed for pesticides. Based upon the results of the inspections, recommendations for each contaminant are discussed separately below.

8.1 ASBESTOS CONCLUSIONS AND RECOMMENDED RESPONSE ACTION

The results of our observation and laboratory analysis did not identify ACM within the samples collected from the site.

AirQuest Project #15671 14 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing

Table 8 – Soil Sample Analytical Results

Sample Sample Depth

(Inches)

Results (mg/kg)

4,4’-DDD 4,4’-DDE 4,4’-DDT Dieldrin Total Chlordane

OCP-1582.1 0-6 ND 0.0018I ND ND ND

OCP-1582.2 18-24 0.0044 0.00075I 0.048 ND ND

OCP-1582.3 0-6 ND 0.019 0.024 0.023 ND

OCP-1582.4 18-24 ND 0.0027I ND 0.0031I ND

OCP-1582.5 0-6 ND 0.0042I ND ND ND

OCP-1582.6 18-24 ND ND ND ND ND

OCP-1582.7 0-6 0.0016I 0.073 0.034 ND 0.0018I

OCP-1582.8 18-24 ND 0.0031I ND ND ND

OCP-1582.9 DUP

(Sample 1) 0-6 ND 0.0033I 0.0041I ND ND

SCTL (Commercial/Industrial) 22 15 15 0.3 14

SCTL (Residential) 4.2 2.9 2.9 0.06 2.8 mg/kg – milligrams/kilogram ND – None Detected by Method Detection Limit SCTL – Soil Cleanup Target Level, Chapter 62-777 Florida Administrative Code I – The Reported Value is Between the Laboratory Method Detection Limit and the Laboratory Practical Quantitation Limit

AirQuest Project #15671 13 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing

8.2 LEAD SCREENING & OSHA LEAD GUIDANCE

Lead was identified in the paint at the site. Under the present OSHA lead construction standard, all identified lead-containing materials affected by construction activities falls under the requirements of 29 CFR 1926. There are no current government guidelines defining a lead-based paint or lead concentration that creates a hazardous atmosphere when disturbed. Based on current OSHA guidelines, for those employees who will be disturbing lead-containing paint (LCP), their employer must make an initial determination by monitoring employee exposure if any employee is exposed to lead at or above 30 micrograms per cubic meter for an eight-hour time weighted average (30 µg/m3 8-hour time weighted average). The employer must implement OSHA prescribed protective measures until they can demonstrate that the employee exposure is not in excess of the action level.

In general, relatively low levels of lead were detected in the various coated surfaces surveyed.

Depending on the degree and type of disturbance of these surfaces (i.e. sanding, cutting, or demolishing), employers may be required to implement varying degrees of OSHA prescribed protective measures. These protective measures must be maintained until it can be demonstrated that employee exposures do not exceed the action level. The employer should also implement and maintain a written compliance program detailing the protective measures they will utilize to control lead exposure during renovation activities.

8.3 TCLP RCRA METALS / LEAD

The results of the laboratory analysis indicate that the waste stream generated from the site is non-hazardous.

8.4 PCBS

The results of the sampling and analysis did not identify PCBs in composite waste stream paint and concrete samples.

8.5 OTHER REGULATED MATERIALS

In general, the items inventoried may be recycled and reclaimed. Special disposal considerations may be required for the TECO natural gas lines and transformer.

8.6 SOIL CONCLUSIONS

The soil analytical results did not identify EPA Method 8081B compounds above the state of Florida Commercial/Industrial or Residential SCTLs.

9 LIMITATIONS

If any suspect hazardous/asbestos containing building materials are encountered during demolition activities that were not sampled in this report, the materials should not be disturbed until they have been sampled and identified as non-hazardous and non-ACM through appropriate investigation and/or laboratory analysis. Many of the roofs at Tyndall Air Force Base were sealed with an EPDM roofing system covering all the original roofing materials. It is possible, if not likely, that

AirQuest Project #15671 14 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing additional suspect asbestos materials are present under the EPDM and were not identified during the asbestos survey.

This report was prepared in a manner consistent with that level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions. This report was prepared for the exclusive use of the client and assigned agents and is not intended for any other purposes. Our report is based on the information available to us at the time of our investigation and limited in scope to the stated purpose and/or the area(s) inspected. Other conditions elsewhere in the site may differ from those in the inspected/ surveyed locations and such conditions are unknown, may change over time, and/or have not been considered. This report does not claim to identify all potential hazards and/or contaminants that may be present, nor does it imply any medical opinion on the relationship of potential health effects with any reported hazards and/ or contaminants. Our opinions are based on our findings and professional expertise, with no guaranty or warranty implied herein. Should additional information become available, we reserve the right to determine the impact, if any, of the new information on our opinions, conclusions, and recommendations if necessary, as warranted by the discovery of the additional information. AirQuest accepts no responsibility for interpretation of this report by others. Its contents shall not be used or relied upon by other parties without prior written authorization by AirQuest.

Appendix I Certifications

JONATHAN ZACHEM, SECRETARYRICK SCOTT, GOVERNOR

STATE OF FLORIDA

DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION

ASBESTOS LICENSING UNIT

THE ASBESTOS CONSULTANT HEREIN IS LICENSED UNDER THE

PROVISIONS OF CHAPTER 469, FLORIDA STATUTES

BOYLE, TRACI-ANNE

Do not alter this document in any form.

AIRQUEST ENVIRONMENTAL INC

LICENSE NUMBER: AX60

EXPIRATION DATE: NOVEMBER 30, 2020

This is your license. It is unlawful for anyone other than the licensee to use this document.

6851 SW 45 ST

DAVIE FL 33314

Always verify licenses online at MyFloridaLicense.com https://www.myfloridalicense.com/LicenseDetail.asp?SID=&id=8c21d1d6249bcaa3338cefa039457259

JONATHAN ZACHEM, SECRETARYRICK SCOTT, GOVERNOR

STATE OF FLORIDA

DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION

BOARD OF PROFESSIONAL GEOLOGISTS

THE PROFESSIONAL GEOLOGIST HEREIN IS LICENSED UNDER THE

PROVISIONS OF CHAPTER 492, FLORIDA STATUTES

SMITH, TED J

Do not alter this document in any form.

1735 CLARENDON AVENUE

LICENSE NUMBER: PG1368

EXPIRATION DATE: JULY 31, 2020

This is your license. It is unlawful for anyone other than the licensee to use this document.

LAKELAND FL 33803

Always verify licenses online at MyFloridaLicense.com https://www.myfloridalicense.com/LicenseDetail.asp?SID=&id=6b0348687cc372fc3b319e7b329b1312

Appendix II Sample Location Diagrams

Sampling Locations

LEGEND

ASBESTOS SAMPLE # 1

PCB PAINT COMPOSITE P

PCB CONCRETE COMPOSITE C

SOIL BORING LOCATION 1

Contract

FACILITIES REDUCTION PROGRAM

FY19 TYNDALL II

W912DY-19-P-0053

DATE: MARCH 2020

Site

TYNDALL AIR FORCE BASE

FLORIDA

BUILDING: VAQ DORM

BUILDING #: 1582

6851 SW 45TH STREET

FT. LAUDERDALE, FLORIDA 33314

AIRQUEST PROJECT 15671

Appendix III Structure Demolition Overview Diagram, Aerial

Photographs and Demolition Overview Photographs

Demolition Overview

BUILDING INFORMATION

NAME VAQ DORM

NUMBER 1582

YEAR BUILT 1943

SQUARE FEET 6,422

STORIES 1

Contract

FACILITIES REDUCTION PROGRAM

FY19 TYNDALL II

W912DY-19-P-0053

DATE: MARCH 2020

Site

TYNDALL AIR FORCE BASE

FLORIDA

BUILDING: VAQ DORM

BUILDING #: 1582

6851 SW 45TH STREET

FT. LAUDERDALE, FLORIDA 33314

AIRQUEST PROJECT 15671

Building 1582 – Pre-Hurricane Aerial Photographs

Overview

Side Angle Side Angle

Side Angle Side Angle

Images Obtained Using Google Earth

Bld 1582 - VAQ DORM Tyndall Air Force Base

AirQuest Environmental, Inc.

Project #15671

Exterior

Tyndall Air Force Base

AirQuest Environmental, Inc.

Interior

Appendix IV Asbestos Laboratory Report and Chain of Custody Record

EMSL Analytical, Inc.

19501 NE 10th Ave. Bay A N. Miami Beach, FL 33179

Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com

171908883EMSL Order:

Customer ID: AQE63

Customer PO:

Project ID:

Attention: Phone:Paul LeBlanc (954) 214-2640

Fax:AirQuest Environmental, Inc. (954) 792-2221

Received Date:6851 Southwest 45th Street 12/06/2019 12:35 PM

Analysis Date:Fort Lauderdale, FL 33314 12/10/2019

Collected Date: 12/04/2019

Project: Tyndall AFB - 15671 - 1582

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

1582-1-Drywall

171908883-0001

None DetectedNon-fibrous (Other)96%Cellulose

Glass

4%

<1%

Brown/Gray

Fibrous

Heterogeneous

Drywall System

1582-1-Joint Compound

171908883-0001A

None DetectedMica

Non-fibrous (Other)

2%

98%

White

Non-Fibrous

Homogeneous

Drywall System

1582-2-Drywall

171908883-0002

None DetectedNon-fibrous (Other)94%Cellulose

Glass

4%

2%

Brown/Gray

Fibrous

Heterogeneous

Drywall System

1582-2-Joint Compound

A

171908883-0002A

None DetectedCa Carbonate

Mica

Non-fibrous (Other)

3%

<1%

97%

White

Non-Fibrous

Homogeneous

Drywall System

1582-2-Tape

171908883-0002B

None DetectedNon-fibrous (Other)5%Cellulose95%Beige

Fibrous

Homogeneous

Drywall System

1582-2-Joint Compound

B

171908883-0002C

None DetectedCa Carbonate

Mica

Non-fibrous (Other)

3%

<1%

97%

Cellulose<1%White

Non-Fibrous

Homogeneous

Drywall System

1582-3-Drywall

171908883-0003

None DetectedNon-fibrous (Other)96%Cellulose

Glass

4%

<1%

Brown/Gray

Fibrous

Heterogeneous

Drywall System

1582-3-Joint Compound

171908883-0003A

None DetectedMica

Non-fibrous (Other)

<1%

100%

Wollastonite<1%White

Non-Fibrous

Homogeneous

Drywall System

1582-4-Drywall

171908883-0004

None DetectedNon-fibrous (Other)95%Cellulose5%Brown/Gray

Fibrous

Heterogeneous

Drywall System

1582-4-Joint Compound

171908883-0004A

None DetectedMica

Non-fibrous (Other)

<1%

100%

White

Non-Fibrous

Homogeneous

Drywall System

1582-5-Drywall

171908883-0005

None DetectedMica

Non-fibrous (Other)

4%

90%

Cellulose

Glass

4%

2%

Brown/White

Fibrous

Heterogeneous

Drywall System

1582-5-Joint Compound

A

171908883-0005A

None DetectedMica

Non-fibrous (Other)

3%

97%

White

Non-Fibrous

Homogeneous

Drywall System

1582-5-Tape

171908883-0005B

None DetectedNon-fibrous (Other)2%Cellulose98%Beige

Fibrous

Homogeneous

Drywall System

1582-5-Joint Compound

B

171908883-0005C

None DetectedMica

Non-fibrous (Other)

2%

98%

White

Non-Fibrous

Homogeneous

Drywall System

1582-6-Drywall

171908883-0006

None DetectedMica

Non-fibrous (Other)

2%

94%

Cellulose4%Brown/White

Fibrous

Heterogeneous

Drywall System

Initial report from: 12/10/2019 16:44:49

Page 1 of 8ASB_PLM_0008_0001 - 1.78 Printed: 12/10/2019 4:44 PM

Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com

171908883EMSL Order:

Customer ID: AQE63

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

1582-6-Joint Compound

A

171908883-0006A

None DetectedMica

Non-fibrous (Other)

3%

97%

White

Non-Fibrous

Homogeneous

Drywall System

1582-6-Tape

171908883-0006B

None DetectedNon-fibrous (Other)2%Cellulose98%Beige

Non-Fibrous

Homogeneous

Drywall System

1582-6-Joint Compound

B

171908883-0006C

None DetectedMica

Non-fibrous (Other)

2%

98%

White

Non-Fibrous

Homogeneous

Drywall System

1582-7

171908883-0007

None DetectedMica

Non-fibrous (Other)

2%

94%

Cellulose4%Brown/White

Fibrous

Heterogeneous

Drywall System

1582-8

171908883-0008

None DetectedPerlite

Non-fibrous (Other)

30%

10%

Cellulose

Min. Wool

50%

10%

Brown/Gray/White

Fibrous

Heterogeneous

Ceiling Tile

1582-9

171908883-0009

None DetectedPerlite

Non-fibrous (Other)

30%

10%

Cellulose

Min. Wool

40%

20%

Brown/Gray/White

Fibrous

Heterogeneous

Ceiling Tile

1582-10

171908883-0010

None DetectedPerlite

Non-fibrous (Other)

30%

10%

Cellulose

Min. Wool

45%

15%

Brown/Gray/White

Fibrous

Heterogeneous

Ceiling Tile

1582-11

171908883-0011

None DetectedPerlite

Non-fibrous (Other)

35%

20%

Cellulose

Min. Wool

35%

10%

Brown/Gray/White

Fibrous

Heterogeneous

Ceiling Tile

1582-12

171908883-0012

None DetectedPerlite

Non-fibrous (Other)

35%

20%

Cellulose

Min. Wool

35%

10%

Brown/Gray/White

Fibrous

Heterogeneous

Ceiling Tile

1582-13-Ceramic Tile

171908883-0013

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Ceramic Tile

1582-13-Grout

171908883-0013A

None DetectedNon-fibrous (Other)100%Wollastonite<1%White

Non-Fibrous

Homogeneous

Ceramic Tile

1582-14-Ceramic Tile

171908883-0014

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Ceramic Tile

1582-14-Grout

171908883-0014A

None DetectedMica

Non-fibrous (Other)

<1%

100%

Cellulose

Wollastonite

<1%

<1%

White

Non-Fibrous

Homogeneous

Ceramic Tile

1582-15-Ceramic Tile

171908883-0015

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Ceramic Tile

1582-15-Grout

171908883-0015A

None DetectedMica

Non-fibrous (Other)

3%

97%

Cellulose

Wollastonite

<1%

<1%

White

Non-Fibrous

Homogeneous

Ceramic Tile

1582-16-Ceramic Tile

171908883-0016

None DetectedNon-fibrous (Other)100%Brown/White

Non-Fibrous

Homogeneous

Ceramic Tile

1582-16-Grout

171908883-0016A

None DetectedQuartz

Non-fibrous (Other)

3%

97%

White/Beige

Non-Fibrous

Homogeneous

Ceramic Tile

1582-17-Ceramic Tile

171908883-0017

None DetectedNon-fibrous (Other)100%Brown/White

Non-Fibrous

Homogeneous

Ceramic Tile

Page 2 of 8ASB_PLM_0008_0001 - 1.78 Printed: 12/10/2019 4:44 PM

Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com

171908883EMSL Order:

Customer ID: AQE63

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

1582-17-Grout

171908883-0017A

None DetectedQuartz

Non-fibrous (Other)

3%

97%

White/Beige

Non-Fibrous

Homogeneous

Ceramic Tile

1582-18

171908883-0018

None DetectedNon-fibrous (Other)98%Cellulose2%Tan

Non-Fibrous

Homogeneous

Carpet Mastic

1582-19

171908883-0019

None DetectedNon-fibrous (Other)95%Cellulose

Synthetic

Glass

2%

<1%

3%

Tan

Non-Fibrous

Homogeneous

Carpet Mastic

1582-20

171908883-0020

None DetectedNon-fibrous (Other)96%Cellulose

Synthetic

Glass

2%

<1%

2%

Tan/Green/Beige

Non-Fibrous

Heterogeneous

Carpet Mastic

1582-21

171908883-0021

None DetectedQuartz

Non-fibrous (Other)

5%

95%

Cellulose<1%Gray/White/Red

Non-Fibrous

Heterogeneous

Concrete Slab

1582-22

171908883-0022

None DetectedQuartz

Non-fibrous (Other)

6%

94%

Cellulose<1%Gray/White/Red

Non-Fibrous

Heterogeneous

Concrete Slab

1582-23

171908883-0023

None DetectedQuartz

Non-fibrous (Other)

8%

92%

Gray

Non-Fibrous

Homogeneous

Concrete Slab

1582-24

171908883-0024

None DetectedQuartz

Non-fibrous (Other)

10%

90%

Gray/Rust

Non-Fibrous

Heterogeneous

Concrete Slab

1582-25

171908883-0025

None DetectedQuartz

Non-fibrous (Other)

10%

90%

Gray/Rust

Non-Fibrous

Homogeneous

Concrete Slab

1582-26

171908883-0026

None DetectedQuartz

Non-fibrous (Other)

7%

93%

Gray

Non-Fibrous

Homogeneous

Concrete Slab

1582-27

171908883-0027

None DetectedQuartz

Non-fibrous (Other)

6%

94%

Gray

Non-Fibrous

Homogeneous

Concrete Slab

1582-28

171908883-0028

None DetectedQuartz

Non-fibrous (Other)

7%

93%

Gray

Non-Fibrous

Homogeneous

Concrete Slab

1582-29

171908883-0029

None DetectedQuartz

Non-fibrous (Other)

25%

75%

Gray

Non-Fibrous

Homogeneous

Epoxy Floor

1582-30

171908883-0030

None DetectedQuartz

Non-fibrous (Other)

35%

65%

Gray

Non-Fibrous

Homogeneous

Epoxy Floor

1582-31

171908883-0031

None DetectedQuartz

Non-fibrous (Other)

33%

67%

Gray

Non-Fibrous

Homogeneous

Epoxy Floor

1582-32

171908883-0032

None DetectedQuartz

Non-fibrous (Other)

15%

45%

Cellulose40%Brown/Gray/Tan

Fibrous

Heterogeneous

Expansion Material

1582-33

171908883-0033

None DetectedNon-fibrous (Other)30%Cellulose70%Brown/Gray/Tan

Fibrous

Heterogeneous

Expansion Material

1582-34-Ceramic Tile

171908883-0034

None DetectedNon-fibrous (Other)100%Red

Non-Fibrous

Homogeneous

Ceramic Tile

1582-34-Grout

171908883-0034A

None DetectedQuartz

Non-fibrous (Other)

8%

92%

Gray

Non-Fibrous

Homogeneous

Ceramic Tile

Page 3 of 8ASB_PLM_0008_0001 - 1.78 Printed: 12/10/2019 4:44 PM

Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com

171908883EMSL Order:

Customer ID: AQE63

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

1582-34-Bedding

171908883-0034B

None DetectedQuartz

Non-fibrous (Other)

10%

90%

Gray

Non-Fibrous

Homogeneous

Ceramic Tile

1582-35-Ceramic Tile

171908883-0035

None DetectedQuartz

Non-fibrous (Other)

<1%

100%

Cellulose<1%Red

Non-Fibrous

Homogeneous

Ceramic Tile

1582-35-Grout

171908883-0035A

None DetectedQuartz

Non-fibrous (Other)

7%

93%

Gray

Non-Fibrous

Homogeneous

Ceramic Tile

1582-35-Mortar

171908883-0035B

None DetectedQuartz

Non-fibrous (Other)

8%

92%

Gray

Non-Fibrous

Homogeneous

Ceramic Tile

1582-36-Floor Tile

171908883-0036

None DetectedNon-fibrous (Other)100%White/Beige

Non-Fibrous

Homogeneous

Vinyl Floor Tile

1582-36-Adhesive/Level er

171908883-0036A

None DetectedNon-fibrous (Other)100%White/Beige

Non-Fibrous

Heterogeneous

Vinyl Floor Tile

1582-37

171908883-0037

None DetectedNon-fibrous (Other)100%Gray/White

Non-Fibrous

Homogeneous

Vinyl Floor Tile

1582-38-Cove Base

171908883-0038

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Vinyl Floor Tile

1582-38-Adhesive

171908883-0038A

None DetectedNon-fibrous (Other)100%Tan

Non-Fibrous

Homogeneous

Vinyl Floor Tile

1582-39-Cove Base A

171908883-0039

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

Vinyl Cove Base

1582-39-Adhesive A

171908883-0039A

None DetectedNon-fibrous (Other)100%Tan

Non-Fibrous

Homogeneous

Vinyl Cove Base

1582-39-Cove Base B

171908883-0039B

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Vinyl Cove Base

1582-39-Adhesive B

171908883-0039C

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

Vinyl Cove Base

1582-39-Joint

Compound

171908883-0039D

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Vinyl Cove Base

1582-40

171908883-0040

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Vinyl Cove Base

1582-41

171908883-0041

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Caulk

1582-42

171908883-0042

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Caulk

1582-43

171908883-0043

None DetectedNon-fibrous (Other)90%Cellulose10%Beige

Fibrous

Homogeneous

Sink Undercoat

Page 4 of 8ASB_PLM_0008_0001 - 1.78 Printed: 12/10/2019 4:44 PM

Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com

171908883EMSL Order:

Customer ID: AQE63

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

1582-44

171908883-0044

None DetectedNon-fibrous (Other)88%Cellulose12%Beige

Fibrous

Homogeneous

Sink Undercoat

1582-45

171908883-0045

None DetectedNon-fibrous (Other)88%Cellulose12%Gray

Fibrous

Homogeneous

Sink Undercoat

1582-46

171908883-0046

None DetectedNon-fibrous (Other)90%Cellulose10%Gray

Fibrous

Homogeneous

Sink Undercoat

1582-47

171908883-0047

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Electrical Putty

1582-48

171908883-0048

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Electrical Putty

1582-49-Shingle A

171908883-0049

None DetectedNon-fibrous (Other)92%Glass8%Red/Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

1582-49-Shingle B

171908883-0049A

None DetectedNon-fibrous (Other)90%Glass10%Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

1582-49-Shingle C

171908883-0049B

None DetectedNon-fibrous (Other)92%Glass8%Red/Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

1582-49-Tar Paper

171908883-0049C

None DetectedNon-fibrous (Other)17%Cellulose83%Black

Fibrous

Homogeneous

Asphalt Shingle Deck

1582-50-Shingle A

171908883-0050

None DetectedNon-fibrous (Other)90%Glass10%Red/Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

1582-50-Built Up

Roofing

171908883-0050A

None DetectedNon-fibrous (Other)88%Glass12%Red/Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

1582-50-Tar Paper A

171908883-0050B

None DetectedNon-fibrous (Other)15%Cellulose85%Black

Fibrous

Homogeneous

Asphalt Shingle Deck

1582-50-Shingle B

171908883-0050C

None DetectedNon-fibrous (Other)92%Glass8%Red/Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

1582-50-Tar Paper B

171908883-0050D

None DetectedNon-fibrous (Other)20%Cellulose80%Black

Fibrous

Homogeneous

Asphalt Shingle Deck

1582-51-Shingle A

171908883-0051

None DetectedNon-fibrous (Other)92%Glass8%Red/Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

1582-51-Shingle B

171908883-0051A

None DetectedNon-fibrous (Other)70%Cellulose30%Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

1582-51-Tar Paper A

171908883-0051B

None DetectedNon-fibrous (Other)20%Cellulose80%Black

Fibrous

Homogeneous

Asphalt Shingle Deck

1582-51-Tar Paper B

171908883-0051C

None DetectedNon-fibrous (Other)8%Cellulose92%Brown/Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

1582-52-Shingle A

171908883-0052

None DetectedQuartz

Non-fibrous (Other)

2%

88%

Glass10%Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

Page 5 of 8ASB_PLM_0008_0001 - 1.78 Printed: 12/10/2019 4:44 PM

Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com

171908883EMSL Order:

Customer ID: AQE63

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

1582-52-Shingle B

171908883-0052A

None DetectedQuartz

Non-fibrous (Other)

2%

88%

Glass10%Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

1582-52-Tar Paper A

171908883-0052B

None DetectedNon-fibrous (Other)25%Cellulose75%Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

1582-52-Tar Paper B

171908883-0052C

None DetectedNon-fibrous (Other)23%Cellulose

Glass

75%

2%

Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

1582-53-Shingle A

171908883-0053

None DetectedQuartz

Non-fibrous (Other)

2%

88%

Glass10%Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

1582-53-Shingle B

171908883-0053A

None DetectedNon-fibrous (Other)93%Glass7%Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

1582-53-Tar Paper A

171908883-0053B

None DetectedQuartz

Non-fibrous (Other)

2%

23%

Cellulose75%Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

1582-53-Tar Paper B

171908883-0053C

None DetectedNon-fibrous (Other)25%Cellulose75%Black

Fibrous

Heterogeneous

Asphalt Shingle Deck

1582-54

171908883-0054

None DetectedNon-fibrous (Other)93%Glass7%Red

Fibrous

Homogeneous

Fire Caulk

1582-55

171908883-0055

None DetectedNon-fibrous (Other)93%Glass7%Red

Fibrous

Homogeneous

Fire Caulk

1582-56

171908883-0056

None DetectedNon-fibrous (Other)84%Cellulose16%Black

Fibrous

Homogeneous

Curb Vent Mastic

1582-57

171908883-0057

None DetectedNon-fibrous (Other)82%Cellulose18%Black

Fibrous

Homogeneous

Curb Vent Mastic

1582-58

171908883-0058

None DetectedNon-fibrous (Other)85%Cellulose15%Black

Fibrous

Homogeneous

Curb Vent Mastic

1582-59

171908883-0059

None DetectedNon-fibrous (Other)84%Cellulose16%Black

Fibrous

Homogeneous

Penetration Mastic

1582-60

171908883-0060

None DetectedNon-fibrous (Other)84%Cellulose16%Black

Fibrous

Homogeneous

Penetration Mastic

1582-61

171908883-0061

None DetectedNon-fibrous (Other)85%Cellulose15%Brown/Black

Fibrous

Homogeneous

Penetration Mastic

1582-62-Caulk

171908883-0062

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Mastic

1582-62-Mastic

171908883-0062A

None DetectedNon-fibrous (Other)86%Cellulose14%Black

Fibrous

Homogeneous

Mastic

1582-63

171908883-0063

None DetectedNon-fibrous (Other)84%Cellulose16%Black

Fibrous

Homogeneous

Mastic

1582-64

171908883-0064

None DetectedQuartz

Non-fibrous (Other)

8%

92%

Gray

Non-Fibrous

Homogeneous

Exterior Stucco

Page 6 of 8ASB_PLM_0008_0001 - 1.78 Printed: 12/10/2019 4:44 PM

Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com

171908883EMSL Order:

Customer ID: AQE63

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

1582-65

171908883-0065

None DetectedQuartz

Non-fibrous (Other)

8%

92%

Gray

Non-Fibrous

Homogeneous

Exterior Stucco

1582-66

171908883-0066

None DetectedQuartz

Non-fibrous (Other)

8%

92%

Gray

Non-Fibrous

Homogeneous

Exterior Stucco

1582-67

171908883-0067

None DetectedQuartz

Non-fibrous (Other)

7%

93%

Gray

Non-Fibrous

Homogeneous

Exterior Stucco

1582-68

171908883-0068

None DetectedQuartz

Non-fibrous (Other)

4%

96%

Gray

Non-Fibrous

Homogeneous

Exterior Stucco

1582-69

171908883-0069

None DetectedQuartz

Non-fibrous (Other)

8%

92%

Gray

Non-Fibrous

Homogeneous

Exterior Stucco

1582-70

171908883-0070

None DetectedQuartz

Non-fibrous (Other)

7%

93%

Gray

Non-Fibrous

Homogeneous

Exterior Stucco Patch

1582-71

171908883-0071

None DetectedQuartz

Non-fibrous (Other)

8%

92%

Gray

Non-Fibrous

Homogeneous

Exterior Stucco Patch

1582-72

171908883-0072

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Caulk

1582-73

171908883-0073

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Caulk

1582-74

171908883-0074

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

Caulk

1582-75

171908883-0075

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

Caulk

1582-76-Drywall

171908883-0076

None DetectedNon-fibrous (Other)98%Cellulose

Glass

2%

<1%

Gray

Fibrous

Homogeneous

Drywall System

1582-76-Joint

Compound

171908883-0076A

None DetectedMica

Non-fibrous (Other)

3%

97%

White

Non-Fibrous

Homogeneous

Drywall System

1582-77-Drywall

171908883-0077

None DetectedNon-fibrous (Other)95%Cellulose

Glass

5%

<1%

Brown/Gray

Fibrous

Heterogeneous

Drywall System

1582-77-Joint

Compound

171908883-0077A

None DetectedMica

Non-fibrous (Other)

2%

98%

White

Non-Fibrous

Homogeneous

Drywall System

Page 7 of 8ASB_PLM_0008_0001 - 1.78 Printed: 12/10/2019 4:44 PM

Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com

171908883EMSL Order:

Customer ID: AQE63

Customer PO:

Project ID:

Analyst(s)

Conner Frymier (44)

Rebecca Newman (25)

Remy Sherman (31)

Waverly Ferguson (23)

Kimberly Wallace, Laboratory Manager or Other Approved Signatory

EMSL maintains liability limited to cost of analysis . The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 "Interim

Method"), but augmented with procedures outlined in the 1993 ("final") version of the method. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . Interpretation and use of test results are the responsibility of the client. All samples received in acceptable condition unless otherwise noted. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. EMSL recommends gravimetric reduction for all non -friable organically bound materials prior to analysis. Estimation of uncertainty is available on request.

Samples analyzed by EMSL Analytical, Inc. Plymouth, MI NVLAP Lab Code 101048-4

Page 8 of 8ASB_PLM_0008_0001 - 1.78 Printed: 12/10/2019 4:44 PM

O r d e r I D

P a g e f d e r I D

P a g e d e r I D

P a g e d e r I D

P a g e

Appendix V Suspect Asbestos Containing Material Photographs

HA Photolog

Tyndall Air Force Base

AirQuest Environmental, Inc.

HA 1 - Drywall System Wall

HA 2 - 12” x 12” Dot-Dash Acoustic Ceiling

Tile

HA 3 - 4” x 4” White Ceramic Wall Tile

HA 4 - 6” x 6” White Ceramic Floor Tile

HA 5 - White Carpet Mastic

HA 6 - Interior Concrete Slab

Tyndall Air Force Base

AirQuest Environmental, Inc.

HA 7 - Exterior Concrete Slab

HA 8 - Exterior Epoxy Floor

HA 9 - Exterior Floor Expansion Material

HA 10 - 6” x 6” Red Ceramic Floor Tile

HA 11 - 12” x 12” Beige Vinyl Floor Tile

HA 12 - 4” White Vinyl Base Cove

Tyndall Air Force Base

AirQuest Environmental, Inc.

HA 13 - White Interior Door Caulk

HA 14 - White Sink Undercoating

HA 15 - Gray Sink Undercoating

HA 16 - Gray Electrical Putty

HA 17 -…