Appendix H(m) - Building 1582 Hazardous Materials Report.pdf
PDF 14 MB Posted
- Attached to
- Demolition of Facilities Phase 6 Federal contract opportunity
- Solicitation number
- FA4819-20-R-1000
About this file
This document contains a pre-demolition survey report for Building 1582 at Tyndall Air Force Base in Florida. The report identifies asbestos-containing materials found in the building and evaluates waste streams, regulated materials, and soil samples prior to the planned demolition. Asbestos was found in multiple materials including floor tiles, ceiling tiles, mastic, and roofing materials. Toxicity Characteristic Leaching Procedure tests were performed on waste streams and detected no hazardous metals above regulatory thresholds. Polychlorinated biphenyls and organochlorine pesticides were not detected in any samples. The report provides conclusions and recommendations for asbestos abatement and handling of regulated materials during demolition in accordance with applicable regulations and standards.
View the file
Other files for this federal contract opportunity
Show all 37
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TYNDALL AFB PRE-DEMOLITION SURVEY
W912DY-19-P-0053
Pre-Demolition Report for Asbestos, Hazardous Materials & Soil Testing
For:
Facilities Reduction Program FY19 Tyndall II
Tyndall AFB, Florida Building 1582 VAQ Dorm
Prepared For:
US Army Corps of Engineers
Engineering & Support Service Center 4910 University Square, Suite 4
Huntsville, Alabama 35816-1822 Facilities Reduction Program
ATTN: CEHNC-ISF
March 2020
AQ#: 15671
ii
CERTIFICATION PAGE
Pre-Demolition Report for Asbestos, Hazardous Materials & Soils Testing
Facilities Reduction Program FY19 Tyndall II Tyndall Air Force Base, Florida
Building 1582 VAQ Dorm
AirQuest Project #15671
Prepared For:
US Army Corps of Engineers Engineering & Support Service Center
4910 University Square, Suite 4 Huntsville, Alabama 35816-1822
ATTN: CEHNC-ISF
Prepared By:
AirQuest Environmental, Inc.
6851 Southwest 45th Street
Fort Lauderdale, Florida 33314
Adrian Amicucci Traci-Anne Boyle, CIH, CSP Asbestos Building Inspector FL Asbestos Consultant #AX-60
Ted Smith, PG
FL Professional Geologist No. PG1368 iii
TABLE OF CONTENTS
PAGE
1 INTRODUCTION AND SITE DESCRIPTION 1
1.1 PURPOSE 1
1.2 SITE DESCRIPTION 1
1.3 DEMOLITION OVERVIEW 1
2 ASBESTOS SURVEY 2
2.1 SURVEY METHODS 2
2.2 LABORATORY ANALYSIS 2
2.3 SUSPECT ASBESTOS-CONTAINING MATERIALS 3
3 LEAD BASED PAINT SCREENING 7
4 TCLP RCRA METALS 7
4.1 TCLP SAMPLE COLLECTION 8
4.2 TCLP SAMPLE RESULTS 8
5 PCBS 8
6 OTHER REGULATED MATERIALS INVENTORY 9
7 SOIL TESTING FOR ORGANOCHLORINE PESTICIDES 13
8 CONCLUSIONS AND RECOMMENDATIONS 13
8.1 ASBESTOS CONCLUSIONS AND RECOMMENDED RESPONSE ACTION 13
8.2 LEAD SCREENING & OSHA LEAD GUIDANCE 13
8.3 TCLP RCRA METALS / LEAD 13
8.4 PCBS 13
8.5 OTHER REGULATED MATERIALS 13
8.6 SOIL CONCLUSIONS 13
9 LIMITATIONS 13
iv
TABLES
Table 1 – Survey Information Table 2 – Asbestos Laboratory Analysis and Summary Table 3 - Lead Based Paint Screening Information Table 4 - Waste Stream Composition Table 5 – Toxicity Characteristic Leachate Procedure Results Table 6 – PCB Results Table 7 – Other Regulated Materials Inventory Table 8 – Soil Sample Analytical Results
APPENDICES
Appendix I – Certifications
Appendix II – Sample Location Diagrams
Appendix III – Structure Demolition Overview (Diagram, Aerial Photographs, Photographs)
Appendix IV – Asbestos Laboratory Report and Chain of Custody Record
Appendix V – Suspect Asbestos Containing Material Photographs
Appendix VI – TCLP Laboratory Report and Chain of Custody Record
Appendix VII – PCB Laboratory Report and Chain of Custody Record
Appendix VIII – Soil Boring Logs and Soil Boring Location Photographs
Appendix IX – Soil Laboratory Report and Chain of Custody Record
AirQuest Environmental, Inc.
AirQuest Project #15671 1 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
1 INTRODUCTION AND SITE DESCRIPTION
In accordance with the Performance Work Statement (PWS) for contract W912DY-19-P-0053, AirQuest Environmental, Inc. (“AirQuest”) performed pre-demolition asbestos, hazardous materials, and soil testing for Building 1582 located at Tyndall Air Force Base, Florida (“the site”).
The surveys were performed by AirQuest Project Team Members as shown in Table 1. Copies of applicable licenses and accreditations are included in Appendix I.
Table 1 – Survey Information
Survey Name Survey Date
Asbestos Adrian Amicucci 04 December 2019
TCLP Waste Stream Travis Holland 04 December 2019
PCB Waste Stream Travis Holland 04 December 2019
Other Regulated Materials Melissa Suarez 04 December 2019
Soil Sample Collection Ted Smith 26 November 2019
TCLP – Toxicity Characteristic Leachate Procedure PCB – Polychlorinated Biphenyl
1.1 PURPOSE
The purpose of this survey was to identify asbestos-containing materials (ACM) within the interior, exterior and roof of the building; to determine if Other Regulated Materials (ORM) materials were present; to complete a waste stream analysis for Toxicity Characteristic Leachate Procedure (TCLP) Resource Conservation and Recovery Act (RCRA)-8 metals and Polychlorinated Biphenyls (PCBs); and to collect soil samples for organochlorine pesticides (OCP) for each structure. Diagrams depicting sampling locations are provided in Appendix II.
The investigation was conducted to facilitate the repairs at Tyndall Air Force Base following Hurricane Michael.
1.2 SITE DESCRIPTION
Building 1582 VAQ Dorm was a 6,422 square foot, single-story structure built in 1943. The building was constructed of concrete block on a concrete slab foundation and finished with exterior stucco. The roof deck was constructed with wood and finished with asphalt shingles. The ceilings were constructed of acoustic ceiling tiles and drywall system. Interior walls were constructed of drywall system and select areas were finished with ceramic tiles. The concrete floor was finished with carpet, vinyl floor tiles and ceramic tiles.
1.3 DEMOLITION OVERVIEW
A diagram illustrating the general layout of the site was prepared using files provided by the client if available or drawn onsite by the AirQuest inspector. AirQuest prepared aerial photographs and photographed an overview of the interior and exterior of the building for purposes of assisting
AirQuest Project #15671 2 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing contractors in evaluation of the demolition requirements. The diagram and photographs are included in Appendix III.
2 ASBESTOS SURVEY
A pre-demolition asbestos survey suitable to meet the requirements of the National Emissions Standard for Hazardous Air Pollutants (NESHAPs) and State of Florida regulations was performed at the site.
2.1 SURVEY METHODS
The sampling protocol used generally followed Asbestos Hazard Emergency Response Act (AHERA) guidelines. AHERA was promulgated by the United States Environmental Protection Agency (EPA) in 1987 and regulated public schools.
Suspect materials were differentiated into three categories: surfacing material, thermal system insulation, or miscellaneous material. Surfacing material is anything that is sprayed or troweled onto a surface; thermal system insulation is material used to insulate HVAC pipes, tanks, etc., and miscellaneous material is any other type of material.
A homogeneous area is defined as an area of surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color and texture. A homogeneous area is not limited to only a room but can be found in several rooms. Sample selection in the building was determined by identifying the homogeneous areas and basing sampling locations upon these areas.
In conducting the building inspection in compliance with local, state, and federal regulations, all suspected ACM which were accessible to the inspector, were either sampled to confirm the actual presence of asbestos or assumed to contain asbestos.
2.2 LABORATORY ANALYSIS
Analysis was performed using Polarized Light Microscopy (PLM) with dispersion staining. The laboratory is rated proficient through National Institute of Standards and Technology- National Voluntary Laboratory Accreditation Program (NIST-NVLAP) for bulk asbestos analysis.
NESHAP defines ACM as containing more than 1% asbestos as determined using PLM (as specified in Appendix E, Subpart E, 40 CFR part 763, Section 1, Polarized Light Microscopy).
NESHAP defines friable ACM as any material containing more than 1% asbestos that, when dry, can be crumbled, pulverized or reduced to a powder by hand pressure. If the asbestos content of a friable material is less than ten (10) percent as determined by a method other than point counting by PLM, the client may elect to verify the asbestos content by point counting using PLM.
Because of the inherent limitations of PLM bulk sample analysis, any friable sample reported as <2% asbestos by PLM was automatically analyzed by the PLM point count method to determine whether it may be regulated under the asbestos NESHAP.
AirQuest Project #15671 3 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
Estimates of quantities of ACM were based upon the identification of suspect materials. Where suspect ACM were located behind walls, above ceilings, beneath carpeting, or other concealed conditions and the quantities cannot be verified, the estimate is based upon the conditions present during the survey. These estimates are not to be considered absolute and should be verified when the ACM is exposed.
2.3 SUSPECT ASBESTOS-CONTAINING MATERIALS
Homogenous areas (HA) of suspect material were identified and samples were collected and submitted under chain of custody to EMSL Analytical, Inc. (“EMSL”) for laboratory analysis of asbestos by PLM. If identified, friable samples with <2% asbestos were further analyzed by the PLM point count method to confirm the PLM results. A copy of the laboratory report and chain of custody record is included in Appendix IV.
Sample descriptions and laboratory results are summarized in Table 2. Photographs of each HA are included in Appendix V.
Table 2 – Asbestos Laboratory Analysis and Summary
HA Sample Number
Description of Suspect Material
Location Asbestos Content %
1 1582-1 Drywall System – Wall 15 North ND
1 1582-2 Drywall System – Wall 14 South ND
1 1582-3 Drywall System – Wall 19 West ND
1 1582-4 Drywall System – Wall 20 North ND
1 1582-5 Drywall System – Wall 12 South ND
1 1582-6 Drywall System – Wall 12 Southwest ND
1 1582-7 Drywall System – Wall 10 South ND
2 1582-8 12” x 12” White ACT Dot- Dash – Ceiling 12 Center ND
2 1582-9 12” x 12” White ACT Dot- Dash – Ceiling 14 Center ND
2 1582-10 12” x 12” White ACT Dot- Dash – Ceiling 15 Center ND
2 1582-11 12” x 12” White ACT Dot- Dash – Ceiling 21 Center ND
2 1582-12 12” x 12” White ACT Dot- Dash – Ceiling 20 Center ND
3 1582-13 4” x 4” Ceramic Tile – Wall 16 North ND
AirQuest Project #15671 4 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
HA Sample Number
Description of Suspect Material
Location Asbestos Content %
3 1582-14 4” x 4” Ceramic Tile – Wall 18 North ND
3 1582-15 4” x 4” Ceramic Tile – Wall 24 South ND
4 1582-16 6” x 6” White Ceramic Tile – Floor 15 East ND
4 1582-17 6” x 6” White Ceramic Tile – Floor 18 East ND
5 1582-18 White Carpet Mastic – Floor 20 Northwest ND
5 1582-19 White Carpet Mastic – Floor 22 Southwest ND
5 1582-20 White Carpet Mastic – Floor 14 Northeast ND
6 1582-21 Interior Concrete Slab – Floor 12 East ND
6 1582-22 Interior Concrete Slab – Floor 12 North ND
6 1582-23 Interior Concrete Slab – Floor 1 South ND
6 1582-24 Interior Concrete Slab – Floor 13 East ND
6 1582-25 Interior Concrete Slab – Floor 13 West ND
7 1582-26 Exterior Concrete Slab – Floor Exterior North ND
7 1582-27 Exterior Concrete Slab – Floor Exterior West ND
7 1582-28 Exterior Concrete Slab – Floor Exterior Southwest ND
8 1582-29 Exterior Epoxy Floor Exterior North ND
8 1582-30 Exterior Epoxy Floor Exterior West ND
8 1582-31 Exterior Epoxy Floor Exterior Northwest ND
9 1582-32 Exterior Floor Expansion Material Exterior Southwest ND
9 1582-33 Exterior Floor Expansion Material Exterior North ND
10 1582-34 6” x 6” Red Ceramic Tile – Floor Exterior South ND
AirQuest Project #15671 5 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
HA Sample Number
Description of Suspect Material
Location Asbestos Content %
10 1582-35 6” x 6” Red Ceramic Tile – Floor Exterior North ND
11 1582-36 12” x 12” Beige Vinyl Floor Tile 10 East ND
11 1582-37 12” x 12” Beige Vinyl Floor Tile 10 West ND
12 1582-38 4” White Vinyl Base Cove 10 North ND
12 1582-39 4” White Vinyl Base Cove 12 North ND
13 1582-40 White Interior Door Caulk 15 West ND
13 1582-41 White Interior Door Caulk 12 West ND
13 1582-42 White Interior Door Caulk 21 West ND
14 1582-43 White Sink Undercoating 15 East ND
14 1582-44 White Sink Undercoating 20 North ND
15 1582-45 Gray Sink Undercoating 12 South ND
15 1582-46 Gray Sink Undercoating 12 South ND
16 1582-47 Gray Electrical Putty 13 Southeast ND
16 1582-48 Gray Electrical Putty 13 Southeast ND
17 1582-49 Asphalt Shingle Deck – Roof Roof Southwest ND
17 1582-50 Asphalt Shingle Deck – Roof Roof South ND
17 1582-51 Asphalt Shingle Deck – Roof Roof East ND
17 1582-52 Asphalt Shingle Deck – Roof Roof North ND
17 1582-53 Asphalt Shingle Deck – Roof Roof Northeast ND
18 1582-54 Red Fire Caulk 13 Southeast ND
18 1582-55 Red Fire Caulk 13 Southeast ND
AirQuest Project #15671 6 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
HA Sample Number
Description of Suspect Material
Location Asbestos Content %
19 1582-56 Black Curb Vent Mastic – Roof Roof North ND
19 1582-57 Black Curb Vent Mastic – Roof Roof Center ND
19 1582-58 Black Curb Vent Mastic – Roof Roof South ND
20 1582-59 Black Penetration Mastic – Roof Roof North ND
20 1582-60 Black Penetration Mastic – Roof Roof Center ND
20 1582-61 Black Penetration Mastic – Roof Roof South ND
21 1582-62 Black Penetration Mastic at Gable – Roof Roof North ND
21 1582-63 Black Penetration Mastic at Gable – Roof Roof Northwest ND
22 1582-64 Exterior Stucco – Wall Exterior West ND
22 1582-65 Exterior Stucco – Wall Exterior Southwest ND
22 1582-66 Exterior Stucco – Wall Exterior South ND
22 1582-67 Exterior Stucco – Wall Exterior East ND
22 1582-68 Exterior Stucco – Wall Exterior Northeast ND
23 1582-69 Exterior Stucco Patch – Wall Exterior North ND
23 1582-70 Exterior Stucco Patch – Wall Exterior East ND
23 1582-71 Exterior Stucco Patch – Wall Exterior Southeast ND
24 1582-72 White Exterior Caulking at Mechanical Room Window Exterior West ND
24 1582-73 White Exterior Caulking at Mechanical Room Window Exterior West ND
25 1582-74 White Interior Wall Expansion Caulk 13 Southeast ND
25 1582-75 White Interior Wall Expansion Caulk 13 Southeast ND
26 1582-76 Drywall System – Ceiling 13 Southeast ND
AirQuest Project #15671 7 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
HA Sample Number
Description of Suspect Material
Location Asbestos Content %
26 1582-77 Drywall System – Ceiling 13 North ND HA- Homogenous Area ND – None Detected ACT- Acoustical Ceiling Tile
3 LEAD BASED PAINT SCREENING
An inspection was conducted to screen for the existence of lead containing painted building components. Testing of the painted building components was performed using an XRF Spectrometer. The XRF is a screening instrument currently recommended by the US Department of Housing and Urban Development (HUD) for analysis of lead levels in paint. The screening was used to assist in determining the need and relative concentrations of lead on painted building components for purposes of designing a sampling scheme for a composite waste stream analysis and demolition contractor worker protection information. The screening was not intended to be a lead-based paint survey in accordance with HUD guidelines. A summary of the screening results is included in Table 3.
Table 3 - Lead Based Paint Screening Information
Structure Color Substrate Location Results1 Pb (mg/cm2)
Wall White Drywall Bedroom Negative 0.1 Wall White Drywall Bedroom Negative 0.2 Wall White Drywall Kitchen Negative 0.1 Wall White Drywall Kitchen Negative -0.2 Wall White Drywall Living Room Negative 0.1 Wall Beige Concrete Exterior Positive 1.4 Wall Beige Concrete Exterior Positive 1.6 Wall Beige Concrete Exterior Negative 0.1 Wall Beige Concrete Exterior Negative -0.2 Door Brown Metal Exterior Negative 0.1
Pb - Lead mg/cm2 – milligrams per square centimeter 1Indicates if the material meets the Department of Housing and Urban Development definition of Lead Based Paint
4 TCLP RCRA METALS
A waste stream composite sample was collected from the building for laboratory analysis of TCLP RCRA-8 Metals.
AirQuest Project #15671 8 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
4.1 TCLP SAMPLE COLLECTION
The sample composition was determined by the composition of the materials comprising the building. Each major building component (such as wood, metal, concrete, glass, etc.) was estimated as a percentage of the weight of the building whole. Once the composition of the building was estimated, representative samples were collected of each material, in an approximate weight proportion as shown in Table 4.
Table 4 - Waste Stream Composition
Waste Stream Component Percentage of
Waste Concrete 60
Metal 10 Wood 10
Drywall 10 Miscellaneous 10
Total Percentage 100
4.2 TCLP SAMPLE RESULTS
The samples were submitted under chain of custody to Spectrum Environmental Laboratories (“Spectrum”), a National Environmental Laboratory Accreditation Conference (NELAC) accredited laboratory, for analysis of TCLP-RCRA-8 Metals by EPA via 1311/6010C/7470A. The results are summarized in Table 5.
Table 5 – Toxicity Characteristic Leachate Procedure Results
Sample TCLP Results (milligrams/liter)
Arsenic Barium Cadmium Chromium Lead Mercury Selenium Silver 1582-
ND 0.198 ND ND 0.055 ND ND ND
Limit1 5.0 100.0 1.0 5.0 5.0 0.2 1.0 5.0 1Regulatory Limit per 40 CFR 261.24 ND – None Detected
5 PCBs Samples for PCBs were collected in general accordance with the EPA Region 1 Standard Operating Procedure for Sampling Porous Surfaces for Polychlorinated Biphenyls (PCBs), May 2011.
The samples were collected from representative painted surfaces to include up to a half-inch of the substrate. The samples were submitted under chain of custody to Spectrum for analysis by EPA Method SW 846 3540C/8020A.
AirQuest Project #15671 9 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
Table 6 – PCB Results
Sample Results (mg/kg)
Aroclor-
Aroclor-
Aroclor-
Aroclor-
Aroclor-
Aroclor-
Aroclor-
PCB-1582-001
Concrete
ND ND ND ND ND ND ND
PCB-1582-002
Paint
ND ND ND ND ND ND ND
1Regulatory Limit per 40 CFR 761.50 Subpart D is 50 mg/kg mg/kg – milligrams/kilogram ND – None Detected
6 OTHER REGULATED MATERIALS INVENTORY
AirQuest conducted another regulated/hazardous materials inventory in general accordance with the Recommended Management Practices for the Removal of Hazardous Materials from Buildings Prior to Demolition prepared by the University of Florida and sponsored by the Florida Department of Environmental Protection, 1999. The inventory included lamps, thermostats, and light switches potentially containing mercury; exit signs, emergency lights, and smoke alarms that have batteries; lighting ballasts which contain polychlorinated biphenyls (PCBs); transformers;
freon, hazardous chemicals and petroleum products; and lead pipes and roof vent flashings.
Certain assumptions for the inspection of fluorescent light ballasts for PCBs were utilized for the building inspections to be completed in a timely and cost-effective manner. As required by regulation, lighting ballasts must not contain PCBs and the label on the ballast must state “No PCB”. AirQuest inventoried 100% of the fluorescent lighting fixtures and inspected a representative of each type of fixture (i.e. 2-foot, 4-foot, etc.) for the “No PCB” labeling.
Each exit sign and emergency lights were presumed to each contain a single lead-acid rechargeable battery. Quantities and types of any ORM found are summarized in Table 7.
AirQuest Project #15671 10 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
Table 7 – Other Regulated Materials Inventory
ORM Component Type/Location Quantity Photographs
Recyclables
Fluorescent Bulbs 48" Lamp 12
Fluorescent Bulbs Compact Bulbs 17
Fluorescent Bulbs Round Bulb 130
Light Ballasts In 48" Fluorescent Fixtures
AirQuest Project #15671 11 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
ORM Component Type/Location Quantity Photographs
LED Bulbs 12
Printer & Toner 4
Fire Pull-Down System
Specialized ORM
Freon In A/C Units 22
AirQuest Project #15671 12 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
ORM Component Type/Location Quantity Photographs
Freon Refrigerator Units 6
Transformers Exterior Pad Mounted
TECO Natural Gas Lines
Fire Extinguishers 3
AirQuest Project #15671 13 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
7 SOIL TESTING FOR ORGANOCHLORINE PESTICIDES
AirQuest advanced four (4) soil borings and collected two (2) samples at each boring location at depths of zero to six inches (0 - 6 in.) and eighteen to twenty-four inches (18 – 24 in.) below land surface using a properly decontaminated hand bucket auger. The samples were generally collected near the four corners of the building as shown in Appendix II.
The soil sampling was conducted in accordance with Florida Department of Environmental Protection (FDEP) Standard Operating Procedures SOP-001-01 FS 3000 (Soil) and SOP-001-01 FQ1000 (Field Quality Control Requirements). One boring log was completed for each building location documenting the observed lithology, visually estimated moisture content, noticeable odors, soil color, sample collection times, sampler’s name, sampling interval and boring completion method. The soil boring log and soil boring location photographs are included in Appendix VIII.
Samples were placed in dedicated sample containers provided by the laboratory and labeled according to the referenced building/structure, collection time, sampler’s name and analysis. A chain of custody form was completed to document the chronology of ownership, control and transfer of the samples. All samples were placed in a cooler filled with ice for transfer to the laboratory.
The soil samples were shipped to Eurofins TestAmerica (“TestAmerica”) in Pensacola, Florida, a NELAC accredited environmental laboratory licensed in the State of Florida, for analysis by EPA Method: 8081B (Organochlorine Pesticides by GC). Analytical results are summarized in Table
8. A copy of the laboratory report and chain of custody record is included in Appendix IX.
The analytical results indicate there are traces of OCPs 4,4’-DDD, 4,4’-DDE, 4,4’-DDT, Dieldrin, and Total Chlordane above the laboratory method detection limit and some above the practical quantitation limit, in most of the soil samples. The detected concentrations do not exceed the Commercial/Industrial or Residential Soil Cleanup Target Levels (SCTLs) provided in Chapter 62-777, FAC, the criteria used by the FDEP.
8 CONCLUSIONS AND RECOMMENDATIONS
A thorough pre-demolition inspection for asbestos and hazardous materials was conducted at the site and an inventory of the materials was created. The soils surrounding the site were sampled and analyzed for pesticides. Based upon the results of the inspections, recommendations for each contaminant are discussed separately below.
8.1 ASBESTOS CONCLUSIONS AND RECOMMENDED RESPONSE ACTION
The results of our observation and laboratory analysis did not identify ACM within the samples collected from the site.
AirQuest Project #15671 14 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
Table 8 – Soil Sample Analytical Results
Sample Sample Depth
(Inches)
Results (mg/kg)
4,4’-DDD 4,4’-DDE 4,4’-DDT Dieldrin Total Chlordane
OCP-1582.1 0-6 ND 0.0018I ND ND ND
OCP-1582.2 18-24 0.0044 0.00075I 0.048 ND ND
OCP-1582.3 0-6 ND 0.019 0.024 0.023 ND
OCP-1582.4 18-24 ND 0.0027I ND 0.0031I ND
OCP-1582.5 0-6 ND 0.0042I ND ND ND
OCP-1582.6 18-24 ND ND ND ND ND
OCP-1582.7 0-6 0.0016I 0.073 0.034 ND 0.0018I
OCP-1582.8 18-24 ND 0.0031I ND ND ND
OCP-1582.9 DUP
(Sample 1) 0-6 ND 0.0033I 0.0041I ND ND
SCTL (Commercial/Industrial) 22 15 15 0.3 14
SCTL (Residential) 4.2 2.9 2.9 0.06 2.8 mg/kg – milligrams/kilogram ND – None Detected by Method Detection Limit SCTL – Soil Cleanup Target Level, Chapter 62-777 Florida Administrative Code I – The Reported Value is Between the Laboratory Method Detection Limit and the Laboratory Practical Quantitation Limit
AirQuest Project #15671 13 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
8.2 LEAD SCREENING & OSHA LEAD GUIDANCE
Lead was identified in the paint at the site. Under the present OSHA lead construction standard, all identified lead-containing materials affected by construction activities falls under the requirements of 29 CFR 1926. There are no current government guidelines defining a lead-based paint or lead concentration that creates a hazardous atmosphere when disturbed. Based on current OSHA guidelines, for those employees who will be disturbing lead-containing paint (LCP), their employer must make an initial determination by monitoring employee exposure if any employee is exposed to lead at or above 30 micrograms per cubic meter for an eight-hour time weighted average (30 µg/m3 8-hour time weighted average). The employer must implement OSHA prescribed protective measures until they can demonstrate that the employee exposure is not in excess of the action level.
In general, relatively low levels of lead were detected in the various coated surfaces surveyed.
Depending on the degree and type of disturbance of these surfaces (i.e. sanding, cutting, or demolishing), employers may be required to implement varying degrees of OSHA prescribed protective measures. These protective measures must be maintained until it can be demonstrated that employee exposures do not exceed the action level. The employer should also implement and maintain a written compliance program detailing the protective measures they will utilize to control lead exposure during renovation activities.
8.3 TCLP RCRA METALS / LEAD
The results of the laboratory analysis indicate that the waste stream generated from the site is non-hazardous.
8.4 PCBS
The results of the sampling and analysis did not identify PCBs in composite waste stream paint and concrete samples.
8.5 OTHER REGULATED MATERIALS
In general, the items inventoried may be recycled and reclaimed. Special disposal considerations may be required for the TECO natural gas lines and transformer.
8.6 SOIL CONCLUSIONS
The soil analytical results did not identify EPA Method 8081B compounds above the state of Florida Commercial/Industrial or Residential SCTLs.
9 LIMITATIONS
If any suspect hazardous/asbestos containing building materials are encountered during demolition activities that were not sampled in this report, the materials should not be disturbed until they have been sampled and identified as non-hazardous and non-ACM through appropriate investigation and/or laboratory analysis. Many of the roofs at Tyndall Air Force Base were sealed with an EPDM roofing system covering all the original roofing materials. It is possible, if not likely, that
AirQuest Project #15671 14 Building 1582 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing additional suspect asbestos materials are present under the EPDM and were not identified during the asbestos survey.
This report was prepared in a manner consistent with that level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions. This report was prepared for the exclusive use of the client and assigned agents and is not intended for any other purposes. Our report is based on the information available to us at the time of our investigation and limited in scope to the stated purpose and/or the area(s) inspected. Other conditions elsewhere in the site may differ from those in the inspected/ surveyed locations and such conditions are unknown, may change over time, and/or have not been considered. This report does not claim to identify all potential hazards and/or contaminants that may be present, nor does it imply any medical opinion on the relationship of potential health effects with any reported hazards and/ or contaminants. Our opinions are based on our findings and professional expertise, with no guaranty or warranty implied herein. Should additional information become available, we reserve the right to determine the impact, if any, of the new information on our opinions, conclusions, and recommendations if necessary, as warranted by the discovery of the additional information. AirQuest accepts no responsibility for interpretation of this report by others. Its contents shall not be used or relied upon by other parties without prior written authorization by AirQuest.
Appendix I Certifications
JONATHAN ZACHEM, SECRETARYRICK SCOTT, GOVERNOR
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
ASBESTOS LICENSING UNIT
THE ASBESTOS CONSULTANT HEREIN IS LICENSED UNDER THE
PROVISIONS OF CHAPTER 469, FLORIDA STATUTES
BOYLE, TRACI-ANNE
Do not alter this document in any form.
AIRQUEST ENVIRONMENTAL INC
LICENSE NUMBER: AX60
EXPIRATION DATE: NOVEMBER 30, 2020
This is your license. It is unlawful for anyone other than the licensee to use this document.
6851 SW 45 ST
DAVIE FL 33314
Always verify licenses online at MyFloridaLicense.com https://www.myfloridalicense.com/LicenseDetail.asp?SID=&id=8c21d1d6249bcaa3338cefa039457259
JONATHAN ZACHEM, SECRETARYRICK SCOTT, GOVERNOR
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
BOARD OF PROFESSIONAL GEOLOGISTS
THE PROFESSIONAL GEOLOGIST HEREIN IS LICENSED UNDER THE
PROVISIONS OF CHAPTER 492, FLORIDA STATUTES
SMITH, TED J
Do not alter this document in any form.
1735 CLARENDON AVENUE
LICENSE NUMBER: PG1368
EXPIRATION DATE: JULY 31, 2020
This is your license. It is unlawful for anyone other than the licensee to use this document.
LAKELAND FL 33803
Always verify licenses online at MyFloridaLicense.com https://www.myfloridalicense.com/LicenseDetail.asp?SID=&id=6b0348687cc372fc3b319e7b329b1312
Appendix II Sample Location Diagrams
Sampling Locations
LEGEND
ASBESTOS SAMPLE # 1
PCB PAINT COMPOSITE P
PCB CONCRETE COMPOSITE C
SOIL BORING LOCATION 1
Contract
FACILITIES REDUCTION PROGRAM
FY19 TYNDALL II
W912DY-19-P-0053
DATE: MARCH 2020
Site
TYNDALL AIR FORCE BASE
FLORIDA
BUILDING: VAQ DORM
BUILDING #: 1582
6851 SW 45TH STREET
FT. LAUDERDALE, FLORIDA 33314
AIRQUEST PROJECT 15671
Appendix III Structure Demolition Overview Diagram, Aerial
Photographs and Demolition Overview Photographs
Demolition Overview
BUILDING INFORMATION
NAME VAQ DORM
NUMBER 1582
YEAR BUILT 1943
SQUARE FEET 6,422
STORIES 1
Contract
FACILITIES REDUCTION PROGRAM
FY19 TYNDALL II
W912DY-19-P-0053
DATE: MARCH 2020
Site
TYNDALL AIR FORCE BASE
FLORIDA
BUILDING: VAQ DORM
BUILDING #: 1582
6851 SW 45TH STREET
FT. LAUDERDALE, FLORIDA 33314
AIRQUEST PROJECT 15671
Building 1582 – Pre-Hurricane Aerial Photographs
Overview
Side Angle Side Angle
Side Angle Side Angle
Images Obtained Using Google Earth
Bld 1582 - VAQ DORM Tyndall Air Force Base
AirQuest Environmental, Inc.
Project #15671
Exterior
Tyndall Air Force Base
AirQuest Environmental, Inc.
Interior
Appendix IV Asbestos Laboratory Report and Chain of Custody Record
EMSL Analytical, Inc.
19501 NE 10th Ave. Bay A N. Miami Beach, FL 33179
Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com
171908883EMSL Order:
Customer ID: AQE63
Customer PO:
Project ID:
Attention: Phone:Paul LeBlanc (954) 214-2640
Fax:AirQuest Environmental, Inc. (954) 792-2221
Received Date:6851 Southwest 45th Street 12/06/2019 12:35 PM
Analysis Date:Fort Lauderdale, FL 33314 12/10/2019
Collected Date: 12/04/2019
Project: Tyndall AFB - 15671 - 1582
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1582-1-Drywall
171908883-0001
None DetectedNon-fibrous (Other)96%Cellulose
Glass
4%
<1%
Brown/Gray
Fibrous
Heterogeneous
Drywall System
1582-1-Joint Compound
171908883-0001A
None DetectedMica
Non-fibrous (Other)
2%
98%
White
Non-Fibrous
Homogeneous
Drywall System
1582-2-Drywall
171908883-0002
None DetectedNon-fibrous (Other)94%Cellulose
Glass
4%
2%
Brown/Gray
Fibrous
Heterogeneous
Drywall System
1582-2-Joint Compound
A
171908883-0002A
None DetectedCa Carbonate
Mica
Non-fibrous (Other)
3%
<1%
97%
White
Non-Fibrous
Homogeneous
Drywall System
1582-2-Tape
171908883-0002B
None DetectedNon-fibrous (Other)5%Cellulose95%Beige
Fibrous
Homogeneous
Drywall System
1582-2-Joint Compound
B
171908883-0002C
None DetectedCa Carbonate
Mica
Non-fibrous (Other)
3%
<1%
97%
Cellulose<1%White
Non-Fibrous
Homogeneous
Drywall System
1582-3-Drywall
171908883-0003
None DetectedNon-fibrous (Other)96%Cellulose
Glass
4%
<1%
Brown/Gray
Fibrous
Heterogeneous
Drywall System
1582-3-Joint Compound
171908883-0003A
None DetectedMica
Non-fibrous (Other)
<1%
100%
Wollastonite<1%White
Non-Fibrous
Homogeneous
Drywall System
1582-4-Drywall
171908883-0004
None DetectedNon-fibrous (Other)95%Cellulose5%Brown/Gray
Fibrous
Heterogeneous
Drywall System
1582-4-Joint Compound
171908883-0004A
None DetectedMica
Non-fibrous (Other)
<1%
100%
White
Non-Fibrous
Homogeneous
Drywall System
1582-5-Drywall
171908883-0005
None DetectedMica
Non-fibrous (Other)
4%
90%
Cellulose
Glass
4%
2%
Brown/White
Fibrous
Heterogeneous
Drywall System
1582-5-Joint Compound
A
171908883-0005A
None DetectedMica
Non-fibrous (Other)
3%
97%
White
Non-Fibrous
Homogeneous
Drywall System
1582-5-Tape
171908883-0005B
None DetectedNon-fibrous (Other)2%Cellulose98%Beige
Fibrous
Homogeneous
Drywall System
1582-5-Joint Compound
B
171908883-0005C
None DetectedMica
Non-fibrous (Other)
2%
98%
White
Non-Fibrous
Homogeneous
Drywall System
1582-6-Drywall
171908883-0006
None DetectedMica
Non-fibrous (Other)
2%
94%
Cellulose4%Brown/White
Fibrous
Heterogeneous
Drywall System
Initial report from: 12/10/2019 16:44:49
Page 1 of 8ASB_PLM_0008_0001 - 1.78 Printed: 12/10/2019 4:44 PM
Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com
171908883EMSL Order:
Customer ID: AQE63
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1582-6-Joint Compound
A
171908883-0006A
None DetectedMica
Non-fibrous (Other)
3%
97%
White
Non-Fibrous
Homogeneous
Drywall System
1582-6-Tape
171908883-0006B
None DetectedNon-fibrous (Other)2%Cellulose98%Beige
Non-Fibrous
Homogeneous
Drywall System
1582-6-Joint Compound
B
171908883-0006C
None DetectedMica
Non-fibrous (Other)
2%
98%
White
Non-Fibrous
Homogeneous
Drywall System
1582-7
171908883-0007
None DetectedMica
Non-fibrous (Other)
2%
94%
Cellulose4%Brown/White
Fibrous
Heterogeneous
Drywall System
1582-8
171908883-0008
None DetectedPerlite
Non-fibrous (Other)
30%
10%
Cellulose
Min. Wool
50%
10%
Brown/Gray/White
Fibrous
Heterogeneous
Ceiling Tile
1582-9
171908883-0009
None DetectedPerlite
Non-fibrous (Other)
30%
10%
Cellulose
Min. Wool
40%
20%
Brown/Gray/White
Fibrous
Heterogeneous
Ceiling Tile
1582-10
171908883-0010
None DetectedPerlite
Non-fibrous (Other)
30%
10%
Cellulose
Min. Wool
45%
15%
Brown/Gray/White
Fibrous
Heterogeneous
Ceiling Tile
1582-11
171908883-0011
None DetectedPerlite
Non-fibrous (Other)
35%
20%
Cellulose
Min. Wool
35%
10%
Brown/Gray/White
Fibrous
Heterogeneous
Ceiling Tile
1582-12
171908883-0012
None DetectedPerlite
Non-fibrous (Other)
35%
20%
Cellulose
Min. Wool
35%
10%
Brown/Gray/White
Fibrous
Heterogeneous
Ceiling Tile
1582-13-Ceramic Tile
171908883-0013
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Ceramic Tile
1582-13-Grout
171908883-0013A
None DetectedNon-fibrous (Other)100%Wollastonite<1%White
Non-Fibrous
Homogeneous
Ceramic Tile
1582-14-Ceramic Tile
171908883-0014
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Ceramic Tile
1582-14-Grout
171908883-0014A
None DetectedMica
Non-fibrous (Other)
<1%
100%
Cellulose
Wollastonite
<1%
<1%
White
Non-Fibrous
Homogeneous
Ceramic Tile
1582-15-Ceramic Tile
171908883-0015
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Ceramic Tile
1582-15-Grout
171908883-0015A
None DetectedMica
Non-fibrous (Other)
3%
97%
Cellulose
Wollastonite
<1%
<1%
White
Non-Fibrous
Homogeneous
Ceramic Tile
1582-16-Ceramic Tile
171908883-0016
None DetectedNon-fibrous (Other)100%Brown/White
Non-Fibrous
Homogeneous
Ceramic Tile
1582-16-Grout
171908883-0016A
None DetectedQuartz
Non-fibrous (Other)
3%
97%
White/Beige
Non-Fibrous
Homogeneous
Ceramic Tile
1582-17-Ceramic Tile
171908883-0017
None DetectedNon-fibrous (Other)100%Brown/White
Non-Fibrous
Homogeneous
Ceramic Tile
Page 2 of 8ASB_PLM_0008_0001 - 1.78 Printed: 12/10/2019 4:44 PM
Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com
171908883EMSL Order:
Customer ID: AQE63
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1582-17-Grout
171908883-0017A
None DetectedQuartz
Non-fibrous (Other)
3%
97%
White/Beige
Non-Fibrous
Homogeneous
Ceramic Tile
1582-18
171908883-0018
None DetectedNon-fibrous (Other)98%Cellulose2%Tan
Non-Fibrous
Homogeneous
Carpet Mastic
1582-19
171908883-0019
None DetectedNon-fibrous (Other)95%Cellulose
Synthetic
Glass
2%
<1%
3%
Tan
Non-Fibrous
Homogeneous
Carpet Mastic
1582-20
171908883-0020
None DetectedNon-fibrous (Other)96%Cellulose
Synthetic
Glass
2%
<1%
2%
Tan/Green/Beige
Non-Fibrous
Heterogeneous
Carpet Mastic
1582-21
171908883-0021
None DetectedQuartz
Non-fibrous (Other)
5%
95%
Cellulose<1%Gray/White/Red
Non-Fibrous
Heterogeneous
Concrete Slab
1582-22
171908883-0022
None DetectedQuartz
Non-fibrous (Other)
6%
94%
Cellulose<1%Gray/White/Red
Non-Fibrous
Heterogeneous
Concrete Slab
1582-23
171908883-0023
None DetectedQuartz
Non-fibrous (Other)
8%
92%
Gray
Non-Fibrous
Homogeneous
Concrete Slab
1582-24
171908883-0024
None DetectedQuartz
Non-fibrous (Other)
10%
90%
Gray/Rust
Non-Fibrous
Heterogeneous
Concrete Slab
1582-25
171908883-0025
None DetectedQuartz
Non-fibrous (Other)
10%
90%
Gray/Rust
Non-Fibrous
Homogeneous
Concrete Slab
1582-26
171908883-0026
None DetectedQuartz
Non-fibrous (Other)
7%
93%
Gray
Non-Fibrous
Homogeneous
Concrete Slab
1582-27
171908883-0027
None DetectedQuartz
Non-fibrous (Other)
6%
94%
Gray
Non-Fibrous
Homogeneous
Concrete Slab
1582-28
171908883-0028
None DetectedQuartz
Non-fibrous (Other)
7%
93%
Gray
Non-Fibrous
Homogeneous
Concrete Slab
1582-29
171908883-0029
None DetectedQuartz
Non-fibrous (Other)
25%
75%
Gray
Non-Fibrous
Homogeneous
Epoxy Floor
1582-30
171908883-0030
None DetectedQuartz
Non-fibrous (Other)
35%
65%
Gray
Non-Fibrous
Homogeneous
Epoxy Floor
1582-31
171908883-0031
None DetectedQuartz
Non-fibrous (Other)
33%
67%
Gray
Non-Fibrous
Homogeneous
Epoxy Floor
1582-32
171908883-0032
None DetectedQuartz
Non-fibrous (Other)
15%
45%
Cellulose40%Brown/Gray/Tan
Fibrous
Heterogeneous
Expansion Material
1582-33
171908883-0033
None DetectedNon-fibrous (Other)30%Cellulose70%Brown/Gray/Tan
Fibrous
Heterogeneous
Expansion Material
1582-34-Ceramic Tile
171908883-0034
None DetectedNon-fibrous (Other)100%Red
Non-Fibrous
Homogeneous
Ceramic Tile
1582-34-Grout
171908883-0034A
None DetectedQuartz
Non-fibrous (Other)
8%
92%
Gray
Non-Fibrous
Homogeneous
Ceramic Tile
Page 3 of 8ASB_PLM_0008_0001 - 1.78 Printed: 12/10/2019 4:44 PM
Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com
171908883EMSL Order:
Customer ID: AQE63
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1582-34-Bedding
171908883-0034B
None DetectedQuartz
Non-fibrous (Other)
10%
90%
Gray
Non-Fibrous
Homogeneous
Ceramic Tile
1582-35-Ceramic Tile
171908883-0035
None DetectedQuartz
Non-fibrous (Other)
<1%
100%
Cellulose<1%Red
Non-Fibrous
Homogeneous
Ceramic Tile
1582-35-Grout
171908883-0035A
None DetectedQuartz
Non-fibrous (Other)
7%
93%
Gray
Non-Fibrous
Homogeneous
Ceramic Tile
1582-35-Mortar
171908883-0035B
None DetectedQuartz
Non-fibrous (Other)
8%
92%
Gray
Non-Fibrous
Homogeneous
Ceramic Tile
1582-36-Floor Tile
171908883-0036
None DetectedNon-fibrous (Other)100%White/Beige
Non-Fibrous
Homogeneous
Vinyl Floor Tile
1582-36-Adhesive/Level er
171908883-0036A
None DetectedNon-fibrous (Other)100%White/Beige
Non-Fibrous
Heterogeneous
Vinyl Floor Tile
1582-37
171908883-0037
None DetectedNon-fibrous (Other)100%Gray/White
Non-Fibrous
Homogeneous
Vinyl Floor Tile
1582-38-Cove Base
171908883-0038
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Vinyl Floor Tile
1582-38-Adhesive
171908883-0038A
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Vinyl Floor Tile
1582-39-Cove Base A
171908883-0039
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
Vinyl Cove Base
1582-39-Adhesive A
171908883-0039A
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Vinyl Cove Base
1582-39-Cove Base B
171908883-0039B
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Vinyl Cove Base
1582-39-Adhesive B
171908883-0039C
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
Vinyl Cove Base
1582-39-Joint
Compound
171908883-0039D
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Vinyl Cove Base
1582-40
171908883-0040
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Vinyl Cove Base
1582-41
171908883-0041
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Caulk
1582-42
171908883-0042
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Caulk
1582-43
171908883-0043
None DetectedNon-fibrous (Other)90%Cellulose10%Beige
Fibrous
Homogeneous
Sink Undercoat
Page 4 of 8ASB_PLM_0008_0001 - 1.78 Printed: 12/10/2019 4:44 PM
Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com
171908883EMSL Order:
Customer ID: AQE63
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1582-44
171908883-0044
None DetectedNon-fibrous (Other)88%Cellulose12%Beige
Fibrous
Homogeneous
Sink Undercoat
1582-45
171908883-0045
None DetectedNon-fibrous (Other)88%Cellulose12%Gray
Fibrous
Homogeneous
Sink Undercoat
1582-46
171908883-0046
None DetectedNon-fibrous (Other)90%Cellulose10%Gray
Fibrous
Homogeneous
Sink Undercoat
1582-47
171908883-0047
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Electrical Putty
1582-48
171908883-0048
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Electrical Putty
1582-49-Shingle A
171908883-0049
None DetectedNon-fibrous (Other)92%Glass8%Red/Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
1582-49-Shingle B
171908883-0049A
None DetectedNon-fibrous (Other)90%Glass10%Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
1582-49-Shingle C
171908883-0049B
None DetectedNon-fibrous (Other)92%Glass8%Red/Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
1582-49-Tar Paper
171908883-0049C
None DetectedNon-fibrous (Other)17%Cellulose83%Black
Fibrous
Homogeneous
Asphalt Shingle Deck
1582-50-Shingle A
171908883-0050
None DetectedNon-fibrous (Other)90%Glass10%Red/Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
1582-50-Built Up
Roofing
171908883-0050A
None DetectedNon-fibrous (Other)88%Glass12%Red/Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
1582-50-Tar Paper A
171908883-0050B
None DetectedNon-fibrous (Other)15%Cellulose85%Black
Fibrous
Homogeneous
Asphalt Shingle Deck
1582-50-Shingle B
171908883-0050C
None DetectedNon-fibrous (Other)92%Glass8%Red/Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
1582-50-Tar Paper B
171908883-0050D
None DetectedNon-fibrous (Other)20%Cellulose80%Black
Fibrous
Homogeneous
Asphalt Shingle Deck
1582-51-Shingle A
171908883-0051
None DetectedNon-fibrous (Other)92%Glass8%Red/Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
1582-51-Shingle B
171908883-0051A
None DetectedNon-fibrous (Other)70%Cellulose30%Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
1582-51-Tar Paper A
171908883-0051B
None DetectedNon-fibrous (Other)20%Cellulose80%Black
Fibrous
Homogeneous
Asphalt Shingle Deck
1582-51-Tar Paper B
171908883-0051C
None DetectedNon-fibrous (Other)8%Cellulose92%Brown/Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
1582-52-Shingle A
171908883-0052
None DetectedQuartz
Non-fibrous (Other)
2%
88%
Glass10%Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
Page 5 of 8ASB_PLM_0008_0001 - 1.78 Printed: 12/10/2019 4:44 PM
Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com
171908883EMSL Order:
Customer ID: AQE63
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1582-52-Shingle B
171908883-0052A
None DetectedQuartz
Non-fibrous (Other)
2%
88%
Glass10%Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
1582-52-Tar Paper A
171908883-0052B
None DetectedNon-fibrous (Other)25%Cellulose75%Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
1582-52-Tar Paper B
171908883-0052C
None DetectedNon-fibrous (Other)23%Cellulose
Glass
75%
2%
Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
1582-53-Shingle A
171908883-0053
None DetectedQuartz
Non-fibrous (Other)
2%
88%
Glass10%Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
1582-53-Shingle B
171908883-0053A
None DetectedNon-fibrous (Other)93%Glass7%Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
1582-53-Tar Paper A
171908883-0053B
None DetectedQuartz
Non-fibrous (Other)
2%
23%
Cellulose75%Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
1582-53-Tar Paper B
171908883-0053C
None DetectedNon-fibrous (Other)25%Cellulose75%Black
Fibrous
Heterogeneous
Asphalt Shingle Deck
1582-54
171908883-0054
None DetectedNon-fibrous (Other)93%Glass7%Red
Fibrous
Homogeneous
Fire Caulk
1582-55
171908883-0055
None DetectedNon-fibrous (Other)93%Glass7%Red
Fibrous
Homogeneous
Fire Caulk
1582-56
171908883-0056
None DetectedNon-fibrous (Other)84%Cellulose16%Black
Fibrous
Homogeneous
Curb Vent Mastic
1582-57
171908883-0057
None DetectedNon-fibrous (Other)82%Cellulose18%Black
Fibrous
Homogeneous
Curb Vent Mastic
1582-58
171908883-0058
None DetectedNon-fibrous (Other)85%Cellulose15%Black
Fibrous
Homogeneous
Curb Vent Mastic
1582-59
171908883-0059
None DetectedNon-fibrous (Other)84%Cellulose16%Black
Fibrous
Homogeneous
Penetration Mastic
1582-60
171908883-0060
None DetectedNon-fibrous (Other)84%Cellulose16%Black
Fibrous
Homogeneous
Penetration Mastic
1582-61
171908883-0061
None DetectedNon-fibrous (Other)85%Cellulose15%Brown/Black
Fibrous
Homogeneous
Penetration Mastic
1582-62-Caulk
171908883-0062
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Mastic
1582-62-Mastic
171908883-0062A
None DetectedNon-fibrous (Other)86%Cellulose14%Black
Fibrous
Homogeneous
Mastic
1582-63
171908883-0063
None DetectedNon-fibrous (Other)84%Cellulose16%Black
Fibrous
Homogeneous
Mastic
1582-64
171908883-0064
None DetectedQuartz
Non-fibrous (Other)
8%
92%
Gray
Non-Fibrous
Homogeneous
Exterior Stucco
Page 6 of 8ASB_PLM_0008_0001 - 1.78 Printed: 12/10/2019 4:44 PM
Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com
171908883EMSL Order:
Customer ID: AQE63
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1582-65
171908883-0065
None DetectedQuartz
Non-fibrous (Other)
8%
92%
Gray
Non-Fibrous
Homogeneous
Exterior Stucco
1582-66
171908883-0066
None DetectedQuartz
Non-fibrous (Other)
8%
92%
Gray
Non-Fibrous
Homogeneous
Exterior Stucco
1582-67
171908883-0067
None DetectedQuartz
Non-fibrous (Other)
7%
93%
Gray
Non-Fibrous
Homogeneous
Exterior Stucco
1582-68
171908883-0068
None DetectedQuartz
Non-fibrous (Other)
4%
96%
Gray
Non-Fibrous
Homogeneous
Exterior Stucco
1582-69
171908883-0069
None DetectedQuartz
Non-fibrous (Other)
8%
92%
Gray
Non-Fibrous
Homogeneous
Exterior Stucco
1582-70
171908883-0070
None DetectedQuartz
Non-fibrous (Other)
7%
93%
Gray
Non-Fibrous
Homogeneous
Exterior Stucco Patch
1582-71
171908883-0071
None DetectedQuartz
Non-fibrous (Other)
8%
92%
Gray
Non-Fibrous
Homogeneous
Exterior Stucco Patch
1582-72
171908883-0072
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Caulk
1582-73
171908883-0073
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Caulk
1582-74
171908883-0074
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
Caulk
1582-75
171908883-0075
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
Caulk
1582-76-Drywall
171908883-0076
None DetectedNon-fibrous (Other)98%Cellulose
Glass
2%
<1%
Gray
Fibrous
Homogeneous
Drywall System
1582-76-Joint
Compound
171908883-0076A
None DetectedMica
Non-fibrous (Other)
3%
97%
White
Non-Fibrous
Homogeneous
Drywall System
1582-77-Drywall
171908883-0077
None DetectedNon-fibrous (Other)95%Cellulose
Glass
5%
<1%
Brown/Gray
Fibrous
Heterogeneous
Drywall System
1582-77-Joint
Compound
171908883-0077A
None DetectedMica
Non-fibrous (Other)
2%
98%
White
Non-Fibrous
Homogeneous
Drywall System
Page 7 of 8ASB_PLM_0008_0001 - 1.78 Printed: 12/10/2019 4:44 PM
Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com
171908883EMSL Order:
Customer ID: AQE63
Customer PO:
Project ID:
Analyst(s)
Conner Frymier (44)
Rebecca Newman (25)
Remy Sherman (31)
Waverly Ferguson (23)
Kimberly Wallace, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 "Interim
Method"), but augmented with procedures outlined in the 1993 ("final") version of the method. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . Interpretation and use of test results are the responsibility of the client. All samples received in acceptable condition unless otherwise noted. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. EMSL recommends gravimetric reduction for all non -friable organically bound materials prior to analysis. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Plymouth, MI NVLAP Lab Code 101048-4
Page 8 of 8ASB_PLM_0008_0001 - 1.78 Printed: 12/10/2019 4:44 PM
O r d e r I D
P a g e f d e r I D
P a g e d e r I D
P a g e d e r I D
P a g e
Appendix V Suspect Asbestos Containing Material Photographs
HA Photolog
Tyndall Air Force Base
AirQuest Environmental, Inc.
HA 1 - Drywall System Wall
HA 2 - 12” x 12” Dot-Dash Acoustic Ceiling
Tile
HA 3 - 4” x 4” White Ceramic Wall Tile
HA 4 - 6” x 6” White Ceramic Floor Tile
HA 5 - White Carpet Mastic
HA 6 - Interior Concrete Slab
Tyndall Air Force Base
AirQuest Environmental, Inc.
HA 7 - Exterior Concrete Slab
HA 8 - Exterior Epoxy Floor
HA 9 - Exterior Floor Expansion Material
HA 10 - 6” x 6” Red Ceramic Floor Tile
HA 11 - 12” x 12” Beige Vinyl Floor Tile
HA 12 - 4” White Vinyl Base Cove
Tyndall Air Force Base
AirQuest Environmental, Inc.
HA 13 - White Interior Door Caulk
HA 14 - White Sink Undercoating
HA 15 - Gray Sink Undercoating
HA 16 - Gray Electrical Putty
HA 17 -…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .