Appendix H(a) - Asbestos Reports.pdf

PDF 180 KB Posted

Attached to
Demolition of Facilities Phase 6 Federal contract opportunity
Solicitation number
FA4819-20-R-1000
Issued by
Department of the Air Force Air Combat Command

About this file

This is a solicitation for demolition services. The 325th Contracting Squadron at Tyndall AFB requires demolition of facilities in Phase 6. The solicitation number is FA4819-20-R-1000. This is a service-disabled veteran-owned small business set-aside with a NAICS code of 238910 and size standard of $16.5M. Firm fixed price quotes are due by June 5, 2020 at 12:00 PM Central Time for award of an indefinite delivery/indefinite quantity contract. The scope includes demolition of unspecified facilities.

View the file

Other files for this federal contract opportunity

Other files attached to Demolition of Facilities Phase 6, newest first.
File Type Posted
Late Questions and Answers.xlsx XLSX spreadsheet
Questions and Answers.xlsx XLSX spreadsheet
Appendix I Monitoring Wells.pdf PDF
RFQ 20R1000 Demo Facilities Phase VI.pdf PDF
Questions and Answers.xlsx XLSX spreadsheet
422.pdf PDF
Appendix C Phase 6 Notes Per Bldg.xlsx XLSX spreadsheet
PWS Demolition Phase 6 - 12 May 2020.pdf PDF
Appendix A Phase 6 Map.pdf PDF
Appendix B Abandoned Utilties.pdf PDF
Appendix H(g) - Building 188 Hazardous Materials Report.pdf PDF
RFQ 20R1000 Demo Facilities Phase VI.pdf PDF
Appendix F Draft Surveys.pdf PDF
Appendix D(e) Photos.pdf PDF
Appendix H(i) - Building 509 Hazardous Materials Report.pdf PDF
Appendix H(d) - Building 162 Hazardous Materials Report.pdf PDF
Appendix A Phase 6 Map.pdf PDF
Appendix B Abandoned Utilties.pdf PDF
Appendix C Phase 6 Notes Per Bldg.xlsx XLSX spreadsheet
Appendix H(m) - Building 1582 Hazardous Materials Report.pdf PDF
Appendix H(f) - Building 179 Hazardous Materials Report.pdf PDF
Appendix D(d) Photos.pdf PDF
Appendix D(a) Photos.pdf PDF
Appendix H(k) - Building 960 Hazardous Materials Report.pdf PDF
Appendix H(e) - Building 164 Hazardous Materials Report.pdf PDF
Appendix D(c) Photos.pdf PDF
Wage Determination FL 20200105.pdf PDF
Appendix E Drawings.pdf PDF
Appendix D(f) Photos.pdf PDF
Appendix D(b) Photos.pdf PDF
Appendix H(c) - Building 108 Hazardous Materials Report.pdf PDF
Appendix H(b) - Building 107 Hazardous Materials Report.pdf PDF
Appendix H(j) - Building 526 Hazardous Materials Report.pdf PDF
Appendix H(l) - Building 1506 Hazardous Materials Report.pdf PDF
Appendix H(h) - Building 504 Hazardous Materials Report.pdf PDF
PWS Demolition Phase 6.pdf PDF
Appendix G MOA Between 325CES_GCEC.pdf PDF
Show all 37

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BUILDING ASBESTOS STATUS REPORT - BUILDING

TYNDALL AIR FORCE BASE

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

MECHANICAL ROOM GM0030041-A Wall insualtion behind concrete wall1 Yes No 01/8/2003 33168

MECHANICAL ROOM GM0030040-A Wall insualtion behind concrete wall1 Yes No 01/8/2003 33168

ROOF

EXTERIOR GM0030039-A Built-up roof materialroof Yes No 01/8/2003 33168

EXTERIOR GM0030038-A Built-up roof materialroof Yes No 01/8/2003 33168

EXTERIOR GM0030037-A Tar around roof ventroof Yes No 01/8/2003 33168

PAGE 1 OF 107/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

180-FIDW-7B1-A Yes No 08/22/1995 NA

180-WLSH-1B3-A Yes No 08/22/1995 NA

180-PIDW-8B3-A Yes No 08/22/1995 NA

180-PIDW-8B2-A Yes No 08/22/1995 NA

180-PIDW-8B1-A Yes No 08/22/1995 NA

180-MISC-4B3-A gray Yes No 08/22/1995 NA

180-MISC-4B1-A gray Yes No 08/22/1995 NA

180-WLSH-1B4-A Yes No 08/22/1995 NA

180-FIDW-7B2-A Yes No8/22/1995 NA

180-2-A tan binder, Room 140 Yes No 08/25/1998 N3878

180-DOOR-9D1-A brown Yes No 08/22/1995 NA

180-DOOR-9B3-A brown Yes No 08/22/1995 NA

180-1-A tan binder, Room 140 Yes No 08/25/1998 N3878

A1017238-B-B Hangar Door Yes No 04/27/2010 ACM Bulk Survey 2010

A1017238-A-A Hangar Door Yes No 04/27/2010 ACM Bulk Survey 2010

GM0900011-1 Bldg 180 Yes No 010/27/2009 ACM Bulk Survey 2009

180-FIDW-7B3-A Yes No8/22/1995 NA

180-WLSH-1B6-A Yes No 08/22/1995 NA

180-WLSH-1B7-A Yes No 08/22/1995 NA

PAGE 1 OF 907/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

GM010023-A off-white/tan fib. Yes No 02/8/2001 NA

180-WLSH-1B5-A Yes No 08/22/1995 NA

BASEBOARD

GM010292-A cove base, Room 102 Yes No 08/16/2001 32850

GM010291-A cove base, Room 102 Yes No 08/16/2001 32850

GM010291-B cove base, Room 102 Yes No 08/16/2001 32850

GM010292-B cove base, Room 102 Yes No 08/16/2001 32850

HALL GM010298-A cove base, hallway Yes No 08/16/2001 32850

HALL GM010298-B cove base, hallway Yes No 08/16/2001 32850

HALL GM010297-A cove base, hallway Yes No 08/16/2001 32850

HALL GM010297-B cove base, hallway Yes No 08/16/2001 32850

CEILING

180-CLLI-3D1-A white/gray Yes No 08/22/1995 NA

OFFICE CLLI-006-B-002-A Ceiling Tile - Lay in, OFF301 Yes No 08/22/1995 GALSON-1995

OFFICE CLLI-006-B-001-A Ceiling Tile - Lay in, OFF301 Yes No 08/22/1995 GALSON-1995

OFFICE CLLI-006-B-003-A Ceiling Tile - Lay in, OFF301 Yes No 08/22/1995 GALSON-1995

OFFICE CLLI-002-D-001-A Ceiling Tile - Lay in, OFF101 Yes No 08/22/1995 GALSON-1995

OFFICE CLLI-006-D-001-A Ceiling Tile - Lay in, OFF301 Yes No 08/22/1995 GALSON-1995

PAGE 2 OF 907/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

CEILING

OFFICE CLLI-003-D-001-A Ceiling Tile - Lay in, OFF101 Yes No 08/22/1995 GALSON-1995

OFFICE CLLI-003-B-003-A Ceiling Tile - Lay in, OFF101 Yes No 08/22/1995 GALSON-1995

OFFICE CLLI-003-B-001-A Ceiling Tile - Lay in, OFF101 Yes No 08/22/1995 GALSON-1995

OFFICE CLLI-002-B-003-A Ceiling Tile - Lay in, OFF101 Yes No 08/22/1995 GALSON-1995

OFFICE CLLI-002-B-002-A Ceiling Tile - Lay in, OFF101 Yes No 08/22/1995 GALSON-1995

OFFICE CLLI-002-B-001-A Ceiling Tile - Lay in, OFF101 Yes No 08/22/1995 GALSON-1995

OFFICE CLLI-003-B-002-A Ceiling Tile - Lay in, OFF101 Yes No 08/22/1995 GALSON-1995

CLLI-005-B-001-A Ceiling Tile - Lay in, TOIL01 Yes No 08/22/1995 GALSON-1995

CLLI-005-B-002-A Ceiling Tile - Lay in, TOIL01 Yes No 08/22/1995 GALSON-1995

J-9470-B-6-06 2' x 2' ceiling tile/wall board, mens & womens res Yes No 08/22/2001 32878

J-9470-B-5-05 2' x 2' ceiling tile/wall board, mens & womens res Yes No 08/22/2001 32878

J-9470-B-4-04 2' x 2' ceiling tile/wall board, mens & womens res Yes No 08/22/2001 32878

CLLI-005-B-003-A Ceiling Tile - Lay in, TOIL01 Yes No 08/22/1995 GALSON-1995

FLOOR

180-1-A white/tan floor tile Yes No 07/10/1994 NA

GM010294-B floor tile, Room 102 Yes No 08/16/2001 32850

GM010293-B floor tile, Room 102 Yes No 08/16/2001 32850

GM010293-A floor tile, Room 102 Yes No 08/16/2001 32850

GM010294-A floor tile, Room 102 Yes No 08/16/2001 32850

PAGE 3 OF 907/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

FLOOR

180-CLLI-6B1-A tan Yes No 08/22/1995 NA

GM010022-A off-white/tan fib.; gold adhesive; off-white vinyl Yes No 02/8/2001 NA

180-MISC-4B2-A gray Yes No 08/22/1995 NA

GM010024-A off-white/tan fib.; off-white vinyl material Yes No 02/8/2001 NA

GM010025-A off-white fib. Yes No 02/8/2001 NA

180-DOOR-9B2-A brown Yes No 08/22/1995 NA

180-DOOR-9B1-A brown Yes No 08/22/1995 NA

180-CLLI-6D1-A tan Yes No 08/22/1995 NA

180-CLLI-6B2-A white/tan Yes No 08/22/1995 NA

180-CLLI-5B3-A brown/of. Yes No 08/22/1995 NA

180-CLLI-5B2-A brown/of. Yes No 08/22/1995 NA

180-CLLI-5B1-A brown/of. Yes No 08/22/1995 NA

180-CLLI-3B3-A white/gray Yes No 08/22/1995 NA

180-CLLI-3B2-A white/gray Yes No 08/22/1995 NA

180-CLLI-3B1-A white/gray Yes No 08/22/1995 NA

180-CLLI-2B2-A brown/white Yes No 08/22/1995 NA

180-CLLI-2B3-A brown/white Yes No 08/22/1995 NA

180-CLLI-2B1-A brown/white Yes No 08/22/1995 NA

180-CLLI-2D1-A brown/white Yes No 08/22/1995 NA

PAGE 4 OF 907/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

FLOOR

180-2-A white/tan floor tile assoc. mastic Yes No 07/10/1994 NA

180-CLLI-6B3-A white/tan Yes No 08/22/1995 NA

HALL GM010296-A floor tile, hallway Yes No 08/16/2001 32850

HALL GM010295-A floor tile, hallway Yes No 08/16/2001 32850

180-FT-1-B Floor tile in flightline side mech room1 Yes No 107/19/2002 N/A RM Request

180-FT-1-A Floor tile in flightline side mech room1 Yes No 37/19/2002 N/A RM Request

OFFICE 180-OF-CM-BG-2-A blue-gray carpet with foam and mastic1 Yes No 06/13/2002 33263

OFFICE 180-OF-CM-BG-1-A blue-gray carpet with foam and mastic1 Yes No 06/13/2002 33263

OFFICE 180-OF-CM-BG-2-B blue-gray carpet with foam and mastic1 Yes No 06/13/2002 33263

OFFICE 180-OF-CM-BG-1-B blue-gray carpet with foam and mastic1 Yes No 06/13/2002 33263

HVAC

MECHANICAL ROOM 180-2-A Bldg 180 HVAC pipe insulation Yes No 08/18/2017 0000

MECHANICAL ROOM 180-1-A Bldg 180 HVAC White pipe wrapping Yes No 08/18/2017 0000

MISC

LOUNGE MISC-004-B-002-A Miscellaneous Materials, BREAK01 Yes No 08/22/1995 GALSON-1995

LOUNGE MISC-004-B-003-A Miscellaneous Materials, BREAK01 Yes No 08/22/1995 GALSON-1995

LOUNGE MISC-004-B-001-A Miscellaneous Materials, BREAK01 Yes No 08/22/1995 GALSON-1995

MECHANICAL ROOM DOOR-009-B-002-A door core insulation - fire door, MECH101 Yes No 08/22/1995 GALSON-1995

PAGE 5 OF 907/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

MISC

MECHANICAL ROOM DOOR-009-B-003-A door core insulation - fire door, MECH101 Yes No 08/22/1995 GALSON-1995

MECHANICAL ROOM DOOR-009-D-001-A door core insulation - fire door, MECH101 Yes No 08/22/1995 GALSON-1995

MECHANICAL ROOM DOOR-009-B-001-A door core insulation - fire door, MECH101 Yes No 08/22/1995 GALSON-1995

SHOP 180-2-C Pipe insulation mastic Hangar1 Yes No 08/23/2002 69284

SHOP 180-1-A Pipe insulation mastic Hangar1 Yes No 08/23/2002 69284

SHOP 180-1-B Pipe insulation mastic Hangar1 Yes No 08/23/2002 69284

SHOP 180-2-A Pipe insulation mastic Hangar1 Yes No 08/23/2002 69284

SHOP 180-2-B Pipe insulation mastic Hangar1 Yes No 08/23/2002 69284

SHOP 180-3-C Pipe insulation mastic Hangar1 Yes No 08/23/2002 69284

SHOP 180-3-B Pipe insulation mastic Hangar1 Yes No 08/23/2002 69284

SHOP 180-3-A Pipe insulation mastic Hangar1 Yes No 08/23/2002 69284

PAINT

SHOP 13-05-01167-007-A Dark Brown Paint1 Yes No 05/7/2013 0000

PIPE INSULATION

1160-2-A beige fiberglass-like siding insulation, exterior Yes No 04/20/1987 NA

GM980496-A yellow fib.; black adhesive; silver foil Yes No 010/16/1998 NA

GM980501-A yellow fib.; black adhesive; white brittle; silver Yes No 010/16/1998 NA

GM980500-A yellow fib.; black adhesive; white brittle; silver Yes No 010/16/1998 NA

PAGE 6 OF 907/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

PIPE INSULATION

GM980499-A yellow fib.; black adhesive; white brittle; silver Yes No 010/16/1998 NA

GM980498-A yellow fib.; black adhesive; white brittle; silver Yes No 010/16/1998 NA

GM980495-A yellow fib.; black adhesive; silver foil Yes No 010/16/1998 NA

GM980497-A yellow fib.; black adhesive; silver foil Yes No 010/16/1998 NA

180-1-2 white paint, water cooler pipe insulation; yellow Yes No 02/21/1996 NA

180-1-3 white paint, water cooler pipe insulation; yellow Yes No 02/21/1996 NA

GM980502-A yellow fib.; black adhesive; white brittle; silver Yes No 010/16/1998 NA

180-1-1 white paint, water cooler pipe insulation; yellow Yes No 02/21/1996 NA

GM980494-A yellow fib.; black adhesive; silver foil Yes No 010/16/1998 NA

HALL 1160-1-A white pipe insulation mineral, north hallway, vert Yes No 604/20/1987 NA

PIDW-008-B-001-A Domestic Water Pipe Insulation, HANGAR01 Yes No 08/22/1995 GALSON-1995

MECHANICAL ROOM PIDW-008-B-003-A Domestic Water Pipe Insulation, MECH101 Yes No 08/22/1995 GALSON-1995

MECHANICAL ROOM FIDW-007-B-001-A Domestic Water Fitting Insulation, MECH101 Yes No 108/22/1995 GALSON-1995

MECHANICAL ROOM FIDW-007-B-002-A Domestic Water Fitting Insulation, MECH101 Yes No 08/22/1995 GALSON-1995

MECHANICAL ROOM FIDW-007-B-003-A Domestic Water Fitting Insulation, MECH101 Yes No 08/22/1995 GALSON-1995

MECHANICAL ROOM PIDW-008-B-002-A Domestic Water Pipe Insulation, MECH101 Yes No 08/22/1995 GALSON-1995

J-9470-B-2-02A pipe wrap, mens & womens restrooms, above ceiling Yes No 08/22/2001 32878

J-9470-B-1-01B pipe wrap, mens & womens restrooms, above ceiling Yes No 08/22/2001 32878

J-9470 B-1-01A yellow pipe insulation, mens & womens restrooms, a Yes No 08/22/2001 32878

PAGE 7 OF 907/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

PIPE INSULATION

J-9470-B-3-03A yellow pipe insulation, mens & womens restrooms, a Yes No 08/22/2001 32878

J-9470-B-3-03B yellow pipe insulation, mens & womens restrooms, a Yes No 08/22/2001 32878

J-9470-B-2-02B pipe wrap, mens & womens restrooms, above ceiling Yes No 08/22/2001 32878

WALL

GM010021-A drywall Yes No 02/8/2001 NA

180-WLSH-1B2-A Yes No 08/22/1995 NA

180-WLSH-1B1-A white/tan Yes No 08/22/1995 NA

OFFICE WLSH-001-B-007-A Wall - sheetrock, OFF101 Yes No 08/22/1995 GALSON-1995

OFFICE WLSH-001-B-006-A Wall - sheetrock, OFF201 Yes No 08/22/1995 GALSON-1995

OFFICE WLSH-001-B-005-A Wall - sheetrock, OFF101 Yes No 08/22/1995 GALSON-1995

OFFICE WLSH-001-B-004-A Wall - sheetrock, OFF301 Yes No 08/22/1995 GALSON-1995

OFFICE WLSH-001-B-003-A Wall - sheetrock, OFF101 Yes No 08/22/1995 GALSON-1995

OFFICE WLSH-001-B-001-A Wall - sheetrock, OFF101 Yes No 08/22/1995 GALSON-1995

OFFICE WLSH-001-B-002-A Wall - sheetrock, OFF101 Yes No 08/22/1995 GALSON-1995

PAGE 8 OF 907/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

ASBESTOS SURVEY VISUAL COMMENTS

BLDG ID : 180

Survey Date Work Order Number Inspector Name Survey/Visual Comments

8/23/2002 69284 Kip Smith Fiberglass insulation and steel bar joists observed above ceilings

7/10/2002 31208 D. Evans There is no hard ceiling. Above ceiling tiles are fiberglass insulation, wooden beams and metal pipes. Pipes not insulated. No suspect ACM noted above ceiling.

6/13/2002 33263 A. Swann All other material identified in SOW appears to have been previously sampled.

PAGE 9 OF 907/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

EXTERIOR 182-6-A Siding Yes No 04/16/2014 0000

BASEBOARD

OFFICE GM020437-A Baseboard w/mastic1 Yes No 010/16/2002 69287

OFFICE GM020437-B Baseboard w/mastic1 Yes No 010/16/2002 69287

OFFICE GM020438-A Baseboard w/mastic1 Yes No 010/16/2002 69287

OFFICE GM020438-B Baseboard w/mastic1 Yes No 010/16/2002 69287

CEILING

J9470-B-18-A 2' x 2' yellow ceiling tile, ready room restroom w Yes No 08/22/2001 32900/01/02

J9470-B-17-A 2' x 2' yellow ceiling tile, ready room restroom w Yes No 08/22/2001 32900/01/02

J9470-B-16-A 2' x 2' yellow ceiling tile, ready room restroom w Yes No 08/22/2001 32900/01/02

LOUNGE CLLI-005-B-001-A Ceiling Tile - Lay in, BREAK01 Yes No 08/21/1995 GALSON-1995

MECHANICAL ROOM CLLI-003-D-001-A Ceiling Tile - Lay in, MECH101 Yes No 08/21/1995 GALSON-1995

MECHANICAL ROOM CLLI-003-B-003-A Ceiling Tile - Lay in, MECH301 Yes No 08/21/1995 GALSON-1995

MECHANICAL ROOM CLLI-003-B-002-A Ceiling Tile - Lay in, MECH301 Yes No 08/21/1995 GALSON-1995

MECHANICAL ROOM CLLI-003-B-001-A Ceiling Tile - Lay in, MECH101 Yes No 08/21/1995 GALSON-1995

OFFICE CLGL-008-B-002-A Ceiling - Glued Tile, OFF401 Yes No 08/21/1995 GALSON-1995

OFFICE CLLI-002-B-003-A Ceiling Tile - Lay in, OFF301 Yes No 08/21/1995 GALSON-1995

OFFICE CLLI-002-B-002-A Ceiling Tile - Lay in, OFF101 Yes No 08/21/1995 GALSON-1995

PAGE 1 OF 607/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

CEILING

OFFICE CLGL-008-B-003-A Ceiling - Glued Tile, OFF401 Yes No 08/21/1995 GALSON-1995

OFFICE CLGL-008-B-001-A Ceiling - Glued Tile, OFF401 Yes No 08/21/1995 GALSON-1995

OFFICE CLLI-002-B-001-A Ceiling Tile - Lay in, OFF101 Yes No 08/21/1995 GALSON-1995

SHOP CLLI-005-B-003-A Ceiling Tile - Lay in, SHOP01 Yes No 08/21/1995 GALSON-1995

SHOP CLLI-005-B-002-A Ceiling Tile - Lay in, SHOP01 Yes No 08/21/1995 GALSON-1995

J9470-B-10-A 2' x 2' yellow ceiling tile, mens restroom, southw Yes No 08/22/2001 32900/01/02

GM000284-A hall white ceiling tiles, mens room, northeast sid Yes No 012/21/2000 56463

GM000285-A hall yellow ceiling tiles, womens room, northeast Yes No 012/21/2000 56463

J9470-B-9-A 2' x 4' yellow ceiling tile, womens restroom, west Yes No 08/22/2001 32900/01/02

J9470-B-8-A 2' x 4' yellow ceiling tile, womens restroom, west Yes No 08/22/2001 32900/01/02

J9470-B-7-A 2' x 4' yellow ceiling tile, womens restroom, west Yes No 08/22/2001 32900/01/02

J9470-B-12-A 2' x 2' yellow ceiling tile, mens restroom, southw Yes No 08/22/2001 32900/01/02

CLLI-004-D-001-A Ceiling Tile - Lay in, TOIL101 Yes No 08/21/1995 GALSON-1995

J9470-B-11-A 2' x 2' yellow ceiling tile, mens restroom, southw Yes No 08/22/2001 32900/01/02

CLLI-004-B-001-A Ceiling Tile - Lay in, TOIL101 Yes No 08/21/1995 GALSON-1995

CLLI-004-B-002-A Ceiling Tile - Lay in, TOIL101 Yes No 08/21/1995 GALSON-1995

CLLI-004-B-003-A Ceiling Tile - Lay in, TOIL101 Yes No 08/21/1995 GALSON-1995

FLOOR

MECHANICAL ROOM GM010256-01B red ceramic floor tile assoc. black mastic, near m Yes No 07/27/2001 32932

PAGE 2 OF 607/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

FLOOR

MECHANICAL ROOM GM010257-02A red ceramic floor tile assoc. black mastic, near m Yes No 07/27/2001 32932

MECHANICAL ROOM GM010257-02B red ceramic floor tile assoc. black mastic, near m Yes No 07/27/2001 32932

MECHANICAL ROOM GM010256-01A red ceramic floor tile assoc. black mastic, near m Yes No 07/27/2001 32932

OFFICE GM020436-B Tile w/glue from carpet1 Yes No 010/16/2002 69287

OFFICE GM020436-A Tile w/glue from carpet1 Yes No 010/16/2002 69287

OFFICE GM020435-B Tile w/glue from carpet1 Yes No 010/16/2002 69287

OFFICE GM020434-B Carpet w/glue1 Yes No 010/16/2002 69287

OFFICE GM020434-A Carpet w/glue1 Yes No 010/16/2002 69287

OFFICE GM020433-B Carpet w/glue1 Yes No 010/16/2002 69287

OFFICE GM020433-A Carpet w/glue1 Yes No 010/16/2002 69287

OFFICE GM020435-A Tile w/glue from carpet1 Yes No 010/16/2002 69287

SHOP 182-2A-A Beige vinyl floor Tile1 Yes No 011/15/2017 0000

SHOP 182-1A-A Gray/White Vinyl Floor Tile1 Yes No 011/15/2017 0000

182-FT2(B)-A mastic, brown brittle Yes No 02/19/2002 69242

182-FT2(A)-A Gray granule, gray brittle Yes No 02/19/2002 69242

182-FT1-A Gray granule, gray brittle Yes No 02/19/2002 69242

MISC

EXTERIOR 182-4-A Red Gasket Exterior pipe fitting Yes No 04/18/2014 341403329

EXTERIOR 182-5-A Black Gasket Yes No 04/16/2014 0000

PAGE 3 OF 607/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

MISC

EXTERIOR 182-4-A Red Gasket Yes No 04/16/2014 0000

EXTERIOR 182-5-A Black Gasket exterior pipe fitting Yes No 04/18/2014 341403329

SHOP 182-2B-A Black Mastic1 Yes No 011/15/2017 0000

SHOP 182-1B-A Black Mastic1 Yes No 011/15/2017 0000

PAINT

EXTERIOR 182-1-A Beige Paint Yes No 04/16/2014 0000

EXTERIOR 182-1-A Beige Paint exterior Walls of Hanger Yes No 04/18/2014 341403329

EXTERIOR 182-2-A Brown Paint exterior trim of Hanger Yes No 04/18/2014 341403329

EXTERIOR 182-3-A Beige Paint and wall texture exterior Yes No 04/18/2014 341403329

EXTERIOR 182-3-A Beige Paint & Wall Texture Yes No 04/16/2014 0000

EXTERIOR 182-6-A Dark Brown siding along crown of East and West walls Yes No 04/18/2014 341403329

EXTERIOR 182-2-A Brown Paint Yes No 04/16/2014 0000

PIPE INSULATION

182-1-A hangar door beige insulation, hangar doors Yes No 02/23/1995 NA

FIT-009-B-002-A Fitting (Type Not Specified.), HANGAR01 Yes No 08/21/1995 GALSON-1995

FIT-009-B-001-A Fitting (Type Not Specified.), HANGAR01 Yes No 658/21/1995 GALSON-1995

FIDW-006-B-003-A Domestic Water Fitting Insulation, HANGAR01 Yes No 08/21/1995 GALSON-1995

PIDW-007-B-001-A Domestic Water Pipe Insulation, HANGAR01 Yes No 08/21/1995 GALSON-1995

PAGE 4 OF 607/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

PIPE INSULATION

FIT-009-B-003-A Fitting (Type Not Specified.), HANGAR01 Yes No 08/21/1995 GALSON-1995

MECHANICAL ROOM FIDW-006-B-002-A Domestic Water Fitting Insulation, MECH101 Yes No 08/21/1995 GALSON-1995

MECHANICAL ROOM FIDW-006-B-001-A Domestic Water Fitting Insulation, MECH101 Yes No 258/21/1995 GALSON-1995

MECHANICAL ROOM PIDW-007-B-002-A Domestic Water Pipe Insulation, MECH101 Yes No 08/21/1995 GALSON-1995

WALL

J9470-B-13-A off-white/brown wall board, southwest wall by entr Yes No 08/22/2001 32900/01/02

J9470-B-15-A off-white/brown wall board, southwest wall by entr Yes No 08/22/2001 32900/01/02

J9470-B-14-A off-white/brown wall board, southwest wall by entr Yes No 08/22/2001 32900/01/02

MECHANICAL ROOM WLSH-001-B-003-A Wall - sheetrock, MECH101 Yes No 08/21/1995 GALSON-1995

SHOP WLSH-001-B-007-A Wall - sheetrock, SHOP01 Yes No 08/21/1995 GALSON-1995

SHOP WLSH-001-B-006-A Wall - sheetrock, SHOP01 Yes No 08/21/1995 GALSON-1995

STORAGE WLSH-001-B-004-A Wall - sheetrock, STO01 Yes No 08/21/1995 GALSON-1995

STORAGE WLSH-001-B-002-A Wall - sheetrock, STO01 Yes No 08/21/1995 GALSON-1995

STORAGE WLSH-001-B-001-A Wall - sheetrock, STO01 Yes No 08/21/1995 GALSON-1995

WLSH-001-B-005-A Wall - sheetrock, TOIL201 Yes No 08/21/1995 GALSON-1995

PAGE 5 OF 607/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

ASBESTOS SURVEY VISUAL COMMENTS

BLDG ID : 182

Survey Date Work Order Number Inspector Name Survey/Visual Comments

10/16/2002 69287 Maring The baseboard was already removed from the room. The glue for the carpet was stuck to the top of the tile. Tile was in good condition, below the tile was concrete.

PAGE 6 OF 607/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

30392-016-A Sink coating, pink, Room 308 Yes No 511/4/1991 EPS-1991

HALL 30387-011-A Sink coating, pink, Hallway near room 210 Yes No 511/4/1991 EPS-1991

OFFICE 421-DW1-A White powder, Drywall between custodian room and C Yes No 06/16/2001 A0837

OFFICE 421-DW2-A White powder/tan fiber, Drywall between custodian Yes No 06/16/2001 A0837

BASEBOARD

CLASS ROOM 13B-1-A baseboard Yes No 04/20/2019 019019901

HALL 13A-1-A baseboard Yes No 04/20/2019 019019901

HALL 421-18-A Cove Base/Adhesive Yes No 03/13/2002 56666

HALL 421-08-A Cove Base/adhesive mastic, brown Yes No 03/13/2002 56666

HALL 13C-1-A baseboard Yes No 04/20/2019 019019901

LOUNGE 421-12-A Cove Base/adhesive mastic, gray Yes No 03/13/2002 56666

LOUNGE 421-11-A Cove Base/adhesive mastic, gray Yes No 03/13/2002 56666

LOUNGE 421-07-A Cove Base/adhesive mastic, brown Yes No 03/13/2002 56666

LOUNGE 421-06-A Cove Base/adhesive mastic, tan Yes No 03/13/2002 56666

OFFICE 421-05-A Cove Base/adhesive mastic, tan Yes No 03/13/2002 56666

OFFICE 421-17-A Cove Base/Adhesive Yes No 03/13/2002 56666

CEILING

30391-015-A ceiling tile, grey/white, Room 308 Yes No 011/4/1991 EPS-1991

PAGE 1 OF 1407/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

CEILING

30402-026-A Ceiling Tile, white/grey, Room 314 Yes No 011/4/1991 EPS-1991

30401-025-A Ceiling Tile, white/grey, Room 309 Yes No 011/4/1991 EPS-1991

30390-014-A ceiling tile, grey/white, Room 308 Yes No 011/4/1991 EPS-1991

30384-008-A Ceiling Tile, white/grey, room 107 Yes No 011/4/1991 EPS-1991

30383-007-A Ceiling Tile, silver/brown, Room 104 Yes No 011/4/1991 EPS-1991

30378-002-A Ceiling Tile, white , Room 103 Yes No 011/4/1991 EPS-1991

30382-006-A Ceiling Tile, grey , Room 108 Yes No 011/4/1991 EPS-1991

421-1-A CT, beige/white, location not given Yes No 012/20/1995 NA

30381-005-A Ceiling Tile, white/grey, Room 101 Yes No 011/4/1991 EPS-1991

BATH ROOM 421-20-A Ceiling Tile, 2x1 Yes No 03/13/2002 56666

HALL 421-21-A Ceiling Tile, 2x2 Yes No 03/13/2002 56666

HALL 421-22-A Ceiling Tile, 2x2, fissured Yes No 03/13/2002 56666

HALL 421-04-A Ceiling tile, 2x2, recessed Yes No 03/13/2002 56666

HALL 30377-001-A Ceiling Tile, grey/white, Hallway near room 100 Yes No 011/4/1991 EPS-1991

HALL 11B-A ceiling tile Yes No 04/20/2019 019019901

HALL 11C-A ceiling tile Yes No 04/20/2019 019019901

HALL 11A-A ceiling tile Yes No 04/20/2019 019019901

LOUNGE 421-03-A Ceiling tile, 2x2, recessed Yes No 03/13/2002 56666

OFFICE CLLI-002-B-003-A Ceiling Tile - Lay in, OFF201 Yes No 05/29/1996 GALSON-1996

PAGE 2 OF 1407/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

CEILING

OFFICE 421-19-A Ceiling Tile, 2x0 Yes No 03/13/2002 56666

OFFICE CLLI-002-B-002-A Ceiling Tile - Lay in, OFF201 Yes No 05/29/1996 GALSON-1996

OFFICE CLLI-002-D-001-A Ceiling Tile - Lay in, OFF201 Yes No 05/29/1996 GALSON-1996

OFFICE CLLI-004-B-001-A Ceiling Tile - Lay in, OFF101 Yes No 05/29/1996 GALSON-1996

OFFICE CLLI-004-B-002-A Ceiling Tile - Lay in, OFF101 Yes No 05/29/1996 GALSON-1996

OFFICE CLLI-004-B-003-A Ceiling Tile - Lay in, OFF101 Yes No 05/29/1996 GALSON-1996

OFFICE CLLI-002-B-001-A Ceiling Tile - Lay in, OFF201 Yes No 05/29/1996 GALSON-1996

FLOOR

30388-012-A Floor Tile, grey, Room 205 Yes No 011/4/1991 EPS-1991

421-2 Green Vinyl, Room 216 Yes No 511/7/1994 NA

30393-017-A floor covering, brown, Room 308 Yes No 011/4/1991 EPS-1991

421-1-1 Black vinyl, location not given Yes No 207/6/1995 NA

421-1-3 Floor tile, tan Adhesive, location not given Yes No 56/27/1995 NA

30394-018-A Floor Tile, grey, Room 308A Yes No 011/4/1991 EPS-1991

421-1-1 Floor tile, tan Adhesive, location not given Yes No 06/27/1995 NA

30389-013-A Floor Tile, adhesive, black, Room 205 Yes No 1011/4/1991 EPS-1991

421-1 Green Vinyl, Room 216 Yes No 1511/7/1994 NA

421-1-2 Floor tile, tan Adhesive, location not given Yes No 06/27/1995 NA

30399-023-A Floor Tile, adhesive, black, Room 320 Yes No 011/4/1991 EPS-1991

PAGE 3 OF 1407/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

FLOOR

B-60-44B 12X12 inch floor tile beige, Room 305 Yes No 010/18/2001 32995

30395-019-A Floor Tile, adhesive, black, Room 308A Yes No 011/4/1991 EPS-1991

B-60-44A 12X12 inch floor tile beige, Room 305 Yes No 010/18/2001 32995

30398-022-A floor tile, brown, Room 320 Yes No 011/4/1991 EPS-1991

421-1-2 Black vinyl, location not given Yes No 57/6/1995 NA

BATH ROOM 10A-3-A wall tile mastic Yes No 04/20/2019 019019901

BATH ROOM 14C-2-A wall tile grout Yes No 04/20/2019 019019901

BATH ROOM 14B-3-A wall tile mastic Yes No 04/20/2019 019019901

BATH ROOM 14B-2-A wall tile grout Yes No 04/20/2019 019019901

BATH ROOM 14C-3-A wall tile mastic Yes No 04/20/2019 019019901

BATH ROOM 7B-2-A floor tile grout Yes No 04/20/2019 019019901

BATH ROOM 10B-2-A wall tile mastic Yes No 04/20/2019 019019901

BATH ROOM 7B-1-A floor tile Yes No 04/20/2019 019019901

BATH ROOM 14A-2-A wall tile grout Yes No 04/20/2019 019019901

BATH ROOM 613120005-A Bathroom Carpet Sq/CC office Yes No 06/13/2012 0000

BATH ROOM 613120005B-A Bathroom Carpet Mastic Sq/CC office Yes No 06/13/2012 0000

BATH ROOM 14A-3-A wall tile mastic Yes No 04/20/2019 019019901

BATH ROOM 7B-3-A floor ile grout Yes No 04/20/2019 019019901

BATH ROOM 15C-1-A floor tile Yes No 04/20/2019 019019901

PAGE 4 OF 1407/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

FLOOR

BATH ROOM 10C-2-A wall tile mastic Yes No 04/20/2019 019019901

BATH ROOM 15C-2-A floor tile mastic Yes No 04/20/2019 019019901

CLASS ROOM 13B-2-A baseboard adhesive Yes No 04/20/2019 019019901

CLASS ROOM 13B-3-A baseboard adhesive compound Yes No 04/20/2019 019019901

EXTERIOR 3A-2-A mortar Yes No 04/20/2019 019019901

EXTERIOR 3B-2-A mortar Yes No 04/20/2019 019019901

EXTERIOR 3C-2-A mortar Yes No 04/20/2019 019019901

HALL 8C-1-A floor tile Yes No 04/20/2019 019019901

HALL 8C-2-A floor tile mastic Yes No 04/20/2019 019019901

HALL 8B-2-A floor tile mastic Yes No 04/20/2019 019019901

HALL 5C-2-A floor tile mastic Yes No 04/20/2019 019019901

HALL 5C-3-A floor tile grout Yes No 04/20/2019 019019901

HALL 8B-1-A floor tile Yes No 04/20/2019 019019901

HALL 8A-2-A floor tile mastic Yes No 04/20/2019 019019901

HALL 421-02-A Floor tile, 12x12, beige/brown mottle/adhesive mas Yes No 03/13/2002 56666

HALL GM030485-B Room 110; Carpet with mastic1 Yes No 05/14/2003 33579

HALL GM030485-A Room 110; Carpet with mastic1 Yes No 05/14/2003 33579

HALL GM030484-B Room 110; Carpet with mastic1 Yes No 05/14/2003 33579

HALL 8A-1-A floor tile Yes No 04/20/2019 019019901

PAGE 5 OF 1407/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

FLOOR

HALL GM030484-A Room 110; Carpet with mastic1 Yes No 05/14/2003 33579

HALL 5A-2-A floor tile mastic Yes No 04/20/2019 019019901

HALL 30400-024-A Floor Tile, grey, Hallway near room 320 Yes No 011/4/1991 EPS-1991

HALL 15A-3-A floor tile thinset Yes No 04/20/2019 019019901

HALL 12A-1-A floor tile Yes No 04/20/2019 019019901

HALL 421-23-A Cream/beige mottle floor tile, 12 x 12, with masti Yes No 03/13/2002 56666

HALL 12B-1-A floor tile Yes No 04/20/2019 019019901

HALL 5B-2-A floor tile mastic Yes No 04/20/2019 019019901

HALL 15B-1-A floor tile Yes No 04/20/2019 019019901

HALL 30397-021-A Floor tile, adhesive, black, Hallway near room 320 Yes No 011/4/1991 EPS-1991

HALL 12A-2-A floor tile mastic Yes No 04/20/2019 019019901

HALL 12C-1-A floor tile Yes No 04/20/2019 019019901

HALL 12C-2-A floor tile mastic Yes No 04/20/2019 019019901

HALL 15A-2-A floor tile grout Yes No 04/20/2019 019019901

HALL 15A-1-A floor tile Yes No 04/20/2019 019019901

HALL 13C-2-A baseboard adhesive Yes No 04/20/2019 019019901

HALL 13A-2-A baseboard adhesive Yes No 04/20/2019 019019901

HALL 30396-020-A Floor Tile, grey, Hallway near room 320 Yes No 011/4/1991 EPS-1991

HALL 421-23-B Cream/beige mottle floor tile, 12 x 12, with masti Yes No 03/13/2002 56666

PAGE 6 OF 1407/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

FLOOR

HALL 5A-1-A floor tile Yes No 04/20/2019 019019901

HALL 13A-3-A baseboard adhesive compound Yes No 04/20/2019 019019901

HALL 5B-1-A floor tile Yes No 04/20/2019 019019901

HALL 15B-2-A floor tile mastic Yes No 04/20/2019 019019901

HALL 5B-3-A floor tile thin set Yes No 04/20/2019 019019901

HALL 5C-1-A floor tile Yes No 04/20/2019 019019901

HALL 421-24-C Cream/beige mottle floor tile, 12 x 12, with masti Yes No 53/13/2002 56666

HALL 421-23-C Cream/beige mottle floor tile, 12 x 12, with masti Yes No 53/13/2002 56666

HALL 421-24-A Cream/beige mottle floor tile, 12 x 12, with masti Yes No 03/13/2002 56666

HALL 12B-2-A floor tile mastic Yes No 04/20/2019 019019901

HALL 421-24-B Cream/beige mottle floor tile, 12 x 12, with masti Yes No 03/13/2002 56666

MISC. USE ROOM 421-16-A Floor tile, 12x12, yellow/adhesive mastic Yes No 03/13/2002 56666

MISC. USE ROOM 421-15-A Floor tile, 12x12, yellow/adhesive mastic Yes No 03/13/2002 56666

MECHANICAL ROOM 9B-1-A floor tile Yes No 04/20/2019 019019901

MECHANICAL ROOM 9C-2-A floor tile mastic Yes No 04/20/2019 019019901

MECHANICAL ROOM 9B-2-A floor tile mastic Yes No 04/20/2019 019019901

MECHANICAL ROOM 9A-2-A floor tile mastic Yes No 04/20/2019 019019901

MECHANICAL ROOM 9A-1-A floor tile Yes No 04/20/2019 019019901

MECHANICAL ROOM 9C-1-A floor tile Yes No 04/20/2019 019019901

PAGE 7 OF 1407/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

FLOOR

OFFICE GM030488-A Drafting/plotter room; Carpet with mastic1 Yes No 05/14/2003 33579

OFFICE 421-CM-B-2-A Rm 203, Blue carpet w/mastic1 Yes No 07/23/2002 33285

OFFICE 421-CM-B-1-A Rm 203, Blue carpet w/mastic1 Yes No 07/23/2002 33285

OFFICE 421-CM-B-1-B Rm 203, Blue carpet w/mastic1 Yes No 07/23/2002 33285

OFFICE GM030486-A Room 300A; Carpet with mastic1 Yes No 05/14/2003 33579

OFFICE 421-13-A Carpet Mastic Yes No 03/13/2002 56666

OFFICE 421-14-A Carpet Mastic Yes No 03/13/2002 56666

OFFICE GM030489-B Drafting/plotter room; Carpet with mastic1 Yes No 05/14/2003 33579

OFFICE GM030489-A Drafting/plotter room; Carpet with mastic1 Yes No 05/14/2003 33579

OFFICE GM030488-B Drafting/plotter room; Carpet with mastic1 Yes No 05/14/2003 33579

OFFICE GM030487-B Room 300A; Carpet with mastic1 Yes No 05/14/2003 33579

OFFICE 421-01-A Floor tile, 12x12, beige/brown mottle/adhesive mas Yes No 03/13/2002 56666

OFFICE GM030486-B Room 300A; Carpet with mastic1 Yes No 05/14/2003 33579

OFFICE GM030487-A Room 300A; Carpet with mastic1 Yes No 05/14/2003 33579

OFFICE 421-CM-B-2-B Rm 203, Blue carpet w/mastic1 Yes No 07/23/2002 33285

OFFICE 421-CM-G-2-B Rm 208, Gray carpet w/mastic1 Yes No 07/23/2002 33285

OFFICE 421-CM-G-2-A Rm 208, Gray carpet w/mastic1 Yes No 07/23/2002 33285

OFFICE 421-CM-G-1-B Rm 208, Gray carpet w/mastic1 Yes No 07/23/2002 33285

OFFICE 421-CM-G-1-A Rm 208, Gray carpet w/mastic1 Yes No 07/23/2002 33285

PAGE 8 OF 1407/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

HVAC

30407-031-A HVAC duct sealant, white, room 321 Yes No 011/4/1991 EPS-1991

HALL 30386-010-A HVAC duct sealant, white, Hallway near room 211 Yes No 011/4/1991 EPS-1991

MECHANICAL ROOM HDUCTP-006-B-003-A DUCT TAPE, MECH101 Yes No 05/29/1996 GALSON-1996

MECHANICAL ROOM 30406-030-A HVAC wrap, black, Mechanical Room B Yes No 011/4/1991 EPS-1991

MECHANICAL ROOM HDUCTP-006-B-001-A DUCT TAPE, MECH101 Yes No 05/29/1996 GALSON-1996

MECHANICAL ROOM HDUCTP-006-B-002-A DUCT TAPE, MECH101 Yes No 05/29/1996 GALSON-1996

MISC

B-58-42B Yellow mastic, Room 305 Yes No 010/18/2001 32995

B-59-43B Yellow mastic, Room 305 Yes No 010/18/2001 32995

B-59-43A Yellow mastic, Room 305 Yes No 010/18/2001 32995

B-58-42A Yellow mastic, Room 305 Yes No 010/18/2001 32995

BATH ROOM 10A-2-A wall tile caulking Yes No 04/20/2019 019019901

EXTERIOR CAULK-003-B-003-A1X Yes No 05/29/1996 GALSON-1996

EXTERIOR 3A-1-A window caulk Yes No 04/20/2019 019019901

EXTERIOR 3C-1-A window caulk Yes No 04/20/2019 019019901

EXTERIOR 421-3-A Gap Filler Yes No 04/18/2014 0000

EXTERIOR 3B-1-A window caulk Yes No 04/20/2019 019019901

EXTERIOR CAULK-003-B-002-A1X Yes No 05/29/1996 GALSON-1996

EXTERIOR 421-4-A Exterior Window Caulk Yes No 04/18/2014 0000

PAGE 9 OF 1407/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

MISC

EXTERIOR 1C-A concrete slab Yes No 04/20/2019 019019901

EXTERIOR 1A-A concrete slab Yes No 04/20/2019 019019901

EXTERIOR 1B-A concrete slab Yes No 04/20/2019 019019901

EXTERIOR CAULK-003-B-001-A1X Yes No 55/29/1996 GALSON-1996

MECHANICAL ROOM 30405-029-A HVAC caulk, grey, Mechanical Room B Yes No 511/4/1991 EPS-1991

PAINT

EXTERIOR 421-2-A Brown Paint & Wall Texture (Columns and Beams) Yes No 04/18/2014 0000

EXTERIOR 421-1-A Beige Paint Exterior Walls Yes No 04/18/2014 0000

PIPE INSULATION

BOILER ROOM 16A-1-A pipe insulation Yes No 04/20/2019 019019901

BOILER ROOM 16A-2-A pipe insulation cover Yes No 04/20/2019 019019901

BOILER ROOM 16B-1-A pipe insulation Yes No 04/20/2019 019019901

BOILER ROOM 16B-2-A pipe insulation jacket Yes No 04/20/2019 019019901

MECHANICAL ROOM 16C-2-A sinsulation cover Yes No 04/20/2019 019019901

MECHANICAL ROOM PITAR-005-B-001-A MECH101 Yes No 05/29/1996 GALSON-1996

MECHANICAL ROOM 30404-028-A Insulation sealant, white/silver/yellow, Mechanica Yes No 011/4/1991 EPS-1991

MECHANICAL ROOM PITAR-005-D-001-A MECH101 Yes No 05/29/1996 GALSON-1996

MECHANICAL ROOM PITAR-005-B-002-A MECH101 Yes No 05/29/1996 GALSON-1996

PAGE 10 OF 1407/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

PIPE INSULATION

MECHANICAL ROOM PITAR-005-B-003-A MECH101 Yes No 05/29/1996 GALSON-1996

MECHANICAL ROOM 30403-027-A Insulation sealant, white/silver, Mechanical Room Yes No 011/4/1991 EPS-1991

MECHANICAL ROOM 16C-1-A insulation Yes No 04/20/2019 019019901

ROOF

EXTERIOR 2B-A roof shingles Yes No 04/20/2019 019019901

EXTERIOR 2C-A roof shingles Yes No 04/20/2019 019019901

EXTERIOR 2A-A roof shingles Yes No 04/20/2019 019019901

ROOF 421-33-A Roof shingle, 3-tab Yes No 03/13/2002 56666

ROOF 421-32-A Roof flashing Yes No 03/13/2002 56666

ROOF 421-31-A Roof flashing Yes No 03/13/2002 56666

ROOF 421-27-A Built-up Roof Yes No 03/13/2002 56666

ROOF 421-28-A Built-up Roof Yes No 03/13/2002 56666

ROOF 421-34-A Roof shingle, 3-tab Yes No 03/13/2002 56666

ROOF 421-29-A Built-up Roof Patch Yes No 03/13/2002 56666

ROOF 421-30-A Built-up Roof Patch Yes No 03/13/2002 56666

WALL

30379-002-A Wall panel, white/brown, Room 103 Yes No 011/4/1991 EPS-1991

30380-004-A Plasterboard wall, white/brown, Room 102 Yes No 011/4/1991 EPS-1991

PAGE 11 OF 1407/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

WALL

BATH ROOM 14A-1-A wall tile Yes No 04/20/2019 019019901

BATH ROOM 7A-A drywall Yes No 04/20/2019 019019901

BATH ROOM 10C-1-A wall tile Yes No 04/20/2019 019019901

BATH ROOM 10B-1-A wall tile Yes No 04/20/2019 019019901

BATH ROOM 14C-1-A wall tile Yes No 04/20/2019 019019901

BATH ROOM 10A-1-A wall tile Yes No 04/20/2019 019019901

BATH ROOM 14B-1-A wall tile Yes No 04/20/2019 019019901

CLASS ROOM 6C-2-A drywall texture Yes No 04/20/2019 019019901

CLASS ROOM 6C-1-A drywall Yes No 04/20/2019 019019901

EXTERIOR 421-1-2A-A Exterior Wall Coating Yes No 04/18/2014 0000

EXTERIOR 421-1-2B-A Plaaster Yes No 04/18/2014 0000

EXTERIOR 4B-A wall Yes No 04/20/2019 019019901

EXTERIOR 4C-A wall Yes No 04/20/2019 019019901

EXTERIOR 4A-A wall Yes No 04/20/2019 019019901

HALL 6A-2-A drywall texture Yes No 04/20/2019 019019901

HALL 6A-1-A drywall Yes No 04/20/2019 019019901

HALL 421-25-A Wallboard/joint compound Yes No 03/13/2002 56666

HALL 421-26-A Wallboard/joint compound Yes No 03/13/2002 56666

HALL 30385-009-A Plasterboard wall, brown/white, Hallway near room Yes No 011/4/1991 EPS-1991

PAGE 12 OF 1407/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

WALL

HALL 421-10-A Wallboard/joint compound Yes No 03/13/2002 56666

LOUNGE 421-09-A Wallboard/joint compound Yes No 03/13/2002 56666

MECHANICAL ROOM WLGL-007-B-003-A Wall Tile - glued on, MECH101 Yes No 05/29/1996 GALSON-1996

MECHANICAL ROOM GM031110-A Sheet Rock1 Yes No 010/29/2003 N/A

MECHANICAL ROOM GM031111-A Sheet Rock1 Yes No 010/29/2003 N/A

MECHANICAL ROOM WLMAS-008-B-003-A Wall Mastic, MECH101 Yes No 05/29/1996 GALSON-1996

MECHANICAL ROOM WLMAS-008-B-001-A Wall Mastic, MECH101 Yes No 55/29/1996 GALSON-1996

MECHANICAL ROOM WLGL-007-B-002-A Wall Tile - glued on, MECH101 Yes No 05/29/1996 GALSON-1996

MECHANICAL ROOM WLGL-007-B-001-A Wall Tile - glued on, MECH101 Yes No 05/29/1996 GALSON-1996

MECHANICAL ROOM WLMAS-008-B-002-A Wall Mastic, MECH101 Yes No 05/29/1996 GALSON-1996

OFFICE GM030641-A Room 100; Sheetrock1 Yes No 06/20/2003 33646

OFFICE GM030642-A Room 100A; Sheetrock1 Yes No 06/20/2003 33646

OFFICE GM030643-A Room 110 Wimms section; Sheetrock1 Yes No 06/20/2003 33646

OFFICE WLSH-001-B-002-A Wall - sheetrock, OFF101 Yes No 05/29/1996 GALSON-1996

OFFICE GM030644-A Room 110 behind the door; Sheetrock1 Yes No 06/20/2003 33646

OFFICE WLSH-001-B-007-A Wall - sheetrock, OFF201 Yes No 05/29/1996 GALSON-1996

OFFICE WLSH-001-B-005-A Wall - sheetrock, OFF201 Yes No 05/29/1996 GALSON-1996

OFFICE WLSH-001-B-003-A Wall - sheetrock, OFF201 Yes No 05/29/1996 GALSON-1996

OFFICE 6B-1-A drywall Yes No 04/20/2019 019019901

PAGE 13 OF 1407/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

WALL

OFFICE WLSH-001-B-001-A Wall - sheetrock, OFF101 Yes No 05/29/1996 GALSON-1996

OFFICE GM030644-B Room 110 behind the door; Sheetrock1 Yes No 06/20/2003 33646

OFFICE 6B-2-A drywall texture Yes No 04/20/2019 019019901

OFFICE WLSH-001-B-004-A Wall - sheetrock, OFF201 Yes No 0.55/29/1996 GALSON-1996

WLSH-001-B-006-A Wall - sheetrock, TOIL201 Yes No 05/29/1996 GALSON-1996

ASBESTOS SURVEY VISUAL COMMENTS

BLDG ID : 421

Survey Date Work Order Number Inspector Name Survey/Visual Comments

3/13/2002 56666 Kip Smith Visual assessment: HVAC ducting was observed to be foil-backed fiberglass. Fiberglass insulation was observed in the attic space.

9/25/2001 NA A. Swann 10X4 section of carpet is being removed and replaced with carpet tiles. Assume mastic is positive for asbestos. Do not cut, sand, or abrade mastic.

1/5/1999 NA Howard Winburn No ACM in main Del-Jen office area.

9/25/1996 NA Bert Lent Request was made to install dimmer switches in the fluorescent light ballasts. Work was stopped since probable asbestos pipe insulation was found in area.

PAGE 14 OF 1407/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

J9244-B-20-A thermal ceramic, north storage dock Yes No 04/9/2001 NA

J9244-B-19-A ceramic fiber board, north storage dock Yes No 04/9/2001 NA

J9244-B-16-A gasket, kiln, southwest corner Yes No 04/9/2001 NA

BASEBOARD

J9244-B-23-A baseboard , northwest room Yes No 04/9/2001 NA

CEILING

FE545-A white ceiling tile, electronic/alarm, e Yes No 010/22/1990 WES-1990

FE546-A white ceiling tile, stock room, n Yes No 010/22/1990 WES-1990

FE549-A white ceiling tile, air comp storage, e Yes No 010/22/1990 WES-1990

FE550-A white ceiling tile, air comp storage, e Yes No 010/22/1990 WES-1990

FE551-A white ceiling tile, workshop 1, n Yes No 010/22/1990 WES-1990

FE554-A white ceiling tile, emcs, e Yes No 010/22/1990 WES-1990

J9244-B-07-A 2X4 foot ceiling tile, room 2, tool room Yes No 04/9/2001 NA

J9244-B-03-A 2X2 foot ceiling tile, room 1, east end Yes No 04/9/2001 NA

J9244-B-04-A ceiling wallboard and compound, room 1, east end Yes No 04/9/2001 NA

J9244-B-06-A 2X4 foot ceiling tile, room 2, tool room Yes No 04/9/2001 NA

SHOP CLLI-004-B-546-A Ceiling Tile - Lay in, MAIN01 Yes No 01/1/1990 WES-1990

SHOP CLLI-004-B-552-A Ceiling Tile - Lay in, MAIN01 Yes No 01/1/1990 WES-1990

PAGE 1 OF 607/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

CEILING

SHOP CLLI-004-B-554-A Ceiling Tile - Lay in, MAIN01 Yes No 01/1/1990 WES-1990

SHOP CLLI-004-B-550-A Ceiling Tile - Lay in, MAIN01 Yes No 01/1/1990 WES-1990

SHOP CLLI-004-B-551-A Ceiling Tile - Lay in, MAIN01 Yes No 01/1/1990 WES-1990

SHOP CLLI-004-B-545-A Ceiling Tile - Lay in, MAIN01 Yes No 01/1/1990 WES-1990

SHOP CLLI-004-B-549-A Ceiling Tile - Lay in, MAIN01 Yes No 01/1/1990 WES-1990

FE552-A white ceiling tile, mens room, c Yes No 010/22/1990 WES-1990

FLOOR

J9244-B-01-A 12X12 inch floor tile, white/tan, room 1, east end Yes No 04/9/2001 NA

F1-A white floor tile, location not given Yes No 011/16/1988 HAR-1988

FE543-A white floor tile, electronic/alarm, s Yes No 010/22/1990 WES-1990

F2-A white floor tile, location not given Yes No 111/16/1988 HAR-1988

F3-A white floor tile, location not given Yes No 111/16/1988 HAR-1988

FE547-A gray floor tile, ref storage 1, e Yes No 110/22/1990 WES-1990

OFFICE J9244-B-02-A 12X12 inch floor tile, white/tan, room 1, east off Yes No 54/9/2001 NA

SHOP FLVCT-001-B-541-A Vinyl Composite Tile Floor, MAIN01 Yes No 11/1/1990 WES-1990

SHOP FLMAS-012-B-553-A Mastic Floor01 Yes No 11/1/1990 WES-1990

SHOP FLVCT-007-B-547-A Vinyl Composite Tile Floor, MAIN01 Yes No 11/1/1990 WES-1990

SHOP FLMAS-002-B-542-A Mastic Floor, MAIN01 Yes No 01/1/1990 WES-1990

SHOP FLMAS-002-B-544-A Mastic Floor, MAIN01 Yes No 01/1/1990 WES-1990

PAGE 2 OF 607/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

FLOOR

SHOP FLMAS-002-B-548-A Mastic Floor, MAIN01 Yes No 01/1/1990 WES-1990

SHOP FLVCT-003-B-543-A Vinyl Composite Tile Floor, MAIN01 Yes No 01/1/1990 WES-1990

STORAGE FE541-A tan floor tile, store room, sw Yes No 110/22/1990 WES-1990

HVAC

MECHANICAL ROOM HFLEX-006-B-561-A HVAC - Flexible duct/flex duct joint, MECH00 Yes No 01/1/1990 WES-1990

MECHANICAL ROOM HDUCT-005-B-560-A Duct, MECH00 Yes No 01/1/1990 WES-1990

MECHANICAL ROOM HDUCT-005-B-559-A Duct, MECH00 Yes No 01/1/1990 WES-1990

MECHANICAL ROOM HDUCT-005-B-558-A Duct, MECH00 Yes No 01/1/1990 WES-1990

MISC

FE544-A yellow mastic, electronic/alarm, s Yes No 010/22/1990 WES-1990

FE548-A black mastic, ref storage 1, e, below ceiling Yes No 010/22/1990 WES-1990

FE553-A brown mastic, co-ed restroom, c Yes No 110/22/1990 WES-1990

5-530-A gray cement, inside of storage cabinet in old asbe Yes No 303/7/1998 NA

STORAGE FE542-A brown mastic, store room, sw Yes No 010/22/1990 WES-1990

PIPE INSULATION

DI3-A duct insulation, location not given Yes No 011/16/1988 HAR-1988

DI2-A duct insulation, location not given Yes No 011/16/1988 HAR-1988

DI1-A duct insulation, location not given Yes No 2011/16/1988 HAR-1988

PAGE 3 OF 607/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

PIPE INSULATION

ATTIC P1-A pipe insulation , attic Yes No 111/16/1988 HAR-1988

MECHANICAL ROOM J9244-B-14-A duct insulation, mechanical room, south center ent Yes No 04/9/2001 NA

MECHANICAL ROOM J9244-B-13-A duct insulation, mechanical room, south center ent Yes No 04/9/2001 NA

MECHANICAL ROOM FE561-A white expansion joint, mech room, sw Yes No 010/22/1990 WES-1990

MECHANICAL ROOM FE560-A white duct insulation, mech room, c Yes No 010/22/1990 WES-1990

MECHANICAL ROOM FE559-A white duct insulation, mech room, n Yes No 010/22/1990 WES-1990

MECHANICAL ROOM FE558-A white duct insulation, mech room, nw Yes No 010/22/1990 WES-1990

ROOF

ROOF R3-A shingle roof, roof Yes No 011/16/1988 HAR-1988

ROOF R4-A shingle roof, roof Yes No 011/16/1988 HAR-1988

ROOF R5-A tar, roof Yes No 211/16/1988 HAR-1988

ROOF 1-A black tar, debris, roof Yes No 06/12/1996 NA

ROOF 2-A black tar, gravel, roof Yes No 06/12/1996 NA

ROOF R1-A shingle roof, roof Yes No 011/16/1988 HAR-1988

ROOF R2-A shingle roof, roof Yes No 011/16/1988 HAR-1988

ROOF J9244-B-22-A roof shingles, southwest roof Yes No 04/9/2001 NA

ROOF RFFELT-009-B-557-A ROOFING FELT MATERIAL, ROOF1R Yes No 01/1/1990 WES-1990

ROOF FE557-A black felt, roof, south Yes No 010/22/1990 WES-1990

ROOF J9244-B-21-A roof shingles, southeast roof Yes No 04/9/2001 NA

PAGE 4 OF 607/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

ROOF

ROOF RFSH-008-B-556-A Roof - Shingled, ROOF1R Yes No 01/1/1990 WES-1990

ROOF FE556-A black shingles, roof, south Yes No 010/22/1990 WES-1990

WALL

J9244-B-10-A wallboard, room 6, north wall Yes No 04/9/2001 NA

J9244-B-09-A wallboard, room 4, south wall Yes No 04/9/2001 NA

J9244-B-12-A wallboard, room 6, northwest wall Yes No 04/9/2001 NA

J9244-B-11-A wallboard, room 6, northeast wall Yes No 04/9/2001 NA

J9244-B-05-A wallboard, room 1, entrance door Yes No 04/9/2001 NA

J9244-B-18-A wallboard, east center wall Yes No 04/9/2001 NA

J9244-B-17-A wallboard, north wall Yes No 04/9/2001 NA

J9244-B-08-A wallboard, room 2, tool room Yes No 04/9/2001 NA

EXTERIOR 530-01-A Exterior stucco1 Yes No 08/22/2002 33245

EXTERIOR 530-07-A Exterior stucco1 Yes No 08/22/2002 33245

EXTERIOR 530-06-A Exterior stucco1 Yes No 08/22/2002 33245

EXTERIOR 530-05-A Exterior stucco1 Yes No 08/22/2002 33245

EXTERIOR 530-04-A Exterior stucco1 Yes No 08/22/2002 33245

EXTERIOR 530-03-A Exterior stucco1 Yes No 08/22/2002 33245

EXTERIOR 530-02-A Exterior stucco1 Yes No 08/22/2002 33245

HALL J9244-B-15-A wallboard, hallway west end Yes No 04/9/2001 NA

PAGE 5 OF 607/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Room_Type Sample Number Sample Descripton Asbestos

Detected?

Floor No.Survey Date: Work

Order No

TOT_ASB

Note: Information shown is incomplete. Contact CEV to coordinate SOW.

WALL

ASBESTOS SURVEY VISUAL COMMENTS

BLDG ID : 530

Survey Date Work Order Number Inspector Name Survey/Visual Comments

4/20/2001 NA Blake Brown Kevin Ouimette observed some friable asbestos falling from the duct work through out the facility. B.B.

comments that bldg 530 is currently abandoned. Suggests staying out of building if there are asbestos concerns. This building is scheduled for renovation within the next several months to make way for a new F-22 facility.

4/18/2001 NA Blake Brown Approximately 4200 sf of floor tile was discovered in building 530 that contains asbestos. All paint inside of building 530 is lead based paint.

11/16/1988 HAR-1988 Every inspected building with an attic space contained loose mineral wool or fiberglass batt insulation resting on the attic floor. Both of these insulating materials are asbestos-contaminated, since damaged ACM insulation from pipes and pipe fittings in the attic has fallen onto the floor.

PAGE 6 OF 607/17/2019REPORT DATE: BUILDING ASBESTOS REPORT

Bldg 126
Bldg 180
Bldg 182
Bldg 421
Bldg 530

File details come from the government source that posted it. Updated .