Appendix H(e) - Building 164 Hazardous Materials Report.pdf
PDF 15 MB Posted
- Attached to
- Demolition of Facilities Phase 6 Federal contract opportunity
- Solicitation number
- FA4819-20-R-1000
About this file
This document contains a pre-demolition survey report and related federal contract opportunity. The pre-demolition survey report identifies asbestos-containing materials, hazardous materials, and soil contaminants present in Building 164 at Tyndall Air Force Base prior to demolition. Suspect materials were sampled and analyzed, with results showing the presence of asbestos in several areas. The report provides conclusions and recommendations regarding abatement of asbestos and other regulated materials prior to demolition.
The related federal contract opportunity is a Request for Quote for demolition services at Tyndall Air Force Base issued by the 325th Contracting Squadron. Quotes are due by June 5, 2020 for a firm fixed price demolition contract to be awarded as a Service-Disabled Veteran-Owned Small Business set-aside. The requirement falls under NAICS code 238910 for site preparation contractors with an estimated value over $16.5 million.
View the file
Other files for this federal contract opportunity
Show all 37
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TYNDALL AFB PRE-DEMOLITION SURVEY
W912DY-19-P-0053
Pre-Demolition Report for Asbestos, Hazardous Materials & Soil Testing
For:
Facilities Reduction Program FY19 Tyndall II
Tyndall AFB, Florida Building 164 95 FS OPS
Prepared For:
US Army Corps of Engineers
Engineering & Support Service Center 4910 University Square, Suite 4
Huntsville, Alabama 35816-1822 Facilities Reduction Program
ATTN: CEHNC-ISF
March 2020
AQ#: 15671
ii
CERTIFICATION PAGE
Pre-Demolition Report for Asbestos, Hazardous Materials & Soils Testing
Facilities Reduction Program FY19 Tyndall II Tyndall Air Force Base, Florida
Building 164 95 FS OPS
AirQuest Project #15671
Prepared For:
US Army Corps of Engineers Engineering & Support Service Center
4910 University Square, Suite 4 Huntsville, Alabama 35816-1822
ATTN: CEHNC-ISF
Prepared By:
AirQuest Environmental, Inc.
6851 Southwest 45th Street
Fort Lauderdale, Florida 33314
Adrian Amicucci Gomez Traci-Anne Boyle, CIH, CSP Asbestos Building Inspector FL Asbestos Consultant #AX-60
Ted Smith, PG
FL Professional Geologist No. PG1368 iii
TABLE OF CONTENTS
PAGE
1 INTRODUCTION AND SITE DESCRIPTION 1
1.1 PURPOSE 1
1.2 SITE DESCRIPTION 1
1.3 DEMOLITION OVERVIEW 1
2 ASBESTOS SURVEY 2
2.1 SURVEY METHODS 2
2.2 LABORATORY ANALYSIS 2
2.3 SUSPECT ASBESTOS-CONTAINING MATERIALS 3
3 LEAD BASED PAINT SCREENING 8
4 TCLP RCRA METALS 8
4.1 TCLP SAMPLE COLLECTION 8
4.2 TCLP SAMPLE RESULTS 9
5 PCBS 9
6 OTHER REGULATED MATERIALS INVENTORY 10
7 SOIL TESTING FOR ORGANOCHLORINE PESTICIDES 15
8 CONCLUSIONS AND RECOMMENDATIONS 16
8.1 ASBESTOS CONCLUSIONS AND RECOMMENDED RESPONSE ACTION 16
8.2 LEAD SCREENING & OSHA LEAD GUIDANCE 19
8.3 TCLP RCRA METALS / LEAD 20
8.4 PCBS 20
8.5 OTHER REGULATED MATERIALS 20
8.6 SOIL CONCLUSIONS 20
9 LIMITATIONS 20
iv
TABLES
Table 1 – Survey Information Table 2 – Asbestos Laboratory Analysis and Summary Table 3 - Lead Based Paint Screening Information Table 4 - Waste Stream Composition Table 5 – Toxicity Characteristic Leachate Procedure Results Table 6 – PCB Results Table 7 – Other Regulated Materials Inventory Table 8 – Soil Sample Analytical Results Table 9 - Asbestos Containing Materials
APPENDICES
Appendix I – Certifications Appendix II – Sample Location Diagrams Appendix III – Structure Demolition Overview (Diagram, Aerial Photographs, Photographs) Appendix IV – Asbestos Laboratory Report and Chain of Custody Record Appendix V – Suspect Asbestos Containing Material Photographs and Asbestos Location Diagram Appendix VI – TCLP Laboratory Report and Chain of Custody Record Appendix VII – PCB Laboratory Report and Chain of Custody Record Appendix VIII – Soil Boring Logs and Soil Boring Location Photographs Appendix IX – Soil Laboratory Report and Chain of Custody Record
AirQuest Environmental, Inc.
AirQuest Project #15671 1 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
1 INTRODUCTION AND SITE DESCRIPTION
In accordance with the Performance Work Statement (PWS) for contract W912DY-19-P-0053, AirQuest Environmental, Inc. (“AirQuest”) performed pre-demolition asbestos, hazardous materials, and soil testing for Building 164 95 FS OFS located at Tyndall Air Force Base, Florida (“the site”). The surveys were performed by AirQuest Project Team Members as shown in Table
1. Copies of applicable licenses and accreditations are included in Appendix I.
Table 1 – Survey Information
Survey Name Survey Date
Asbestos Adrian Amicucci Gomez 04 December 2019 06 January 2020
TCLP Waste Stream Travis Holland 02 December 2019
PCB Waste Stream Travis Holland 02 December 2019
Other Regulated Materials Melissa Suarez 02 December 2019
Soil Sample Collection Ted Smith 23 November 2019
TCLP – Toxicity Characteristic Leachate Procedure PCB – Polychlorinated Biphenyl
1.1 PURPOSE
The purpose of this survey was to identify asbestos-containing materials (ACM) within the interior, exterior and roof of the building; to determine if Other Regulated Materials (ORM) materials were present; to complete a waste stream analysis for Toxicity Characteristic Leachate Procedure (TCLP) Resource Conservation and Recovery Act (RCRA)-8 metals and Polychlorinated Biphenyls (PCBs); and to collect soil samples for organochlorine pesticides (OCP) for each structure. Diagrams depicting sampling locations are provided in Appendix II.
The investigation was conducted to facilitate the repairs at Tyndall Air Force Base following Hurricane Michael.
1.2 SITE DESCRIPTION
Building 164 95 FS OPS was a 14,322 square foot, single-story structure built in 1961. The building was constructed with concrete block on a concrete slab foundation. The roof was constructed of concrete with a covered tar and gravel roof deck and a standing seam metal main roof. The ceilings were constructed of acoustical ceiling tile. The interior walls were constructed of knockdown drywall system and finished with ceramic wall tile in select areas. The floor was finished with carpet, ceramic tile and vinyl floor tile.
1.3 DEMOLITION OVERVIEW
A diagram illustrating the general layout of the site was prepared using files provided by the client if available or drawn onsite by the AirQuest inspector. AirQuest prepared aerial photographs and photographed an overview of the interior and exterior of the building for purposes of assisting
AirQuest Project #15671 2 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing contractors in evaluation of the demolition requirements. The diagram and photographs are included in Appendix III.
2 ASBESTOS SURVEY
A pre-demolition asbestos survey suitable to meet the requirements of the National Emissions Standard for Hazardous Air Pollutants (NESHAPs) and State of Florida regulations was performed at the site.
2.1 SURVEY METHODS
The sampling protocol used generally followed Asbestos Hazard Emergency Response Act (AHERA) guidelines. AHERA was promulgated by the United States Environmental Protection Agency (EPA) in 1987 and regulated public schools.
Suspect materials were differentiated into three categories: surfacing material, thermal system insulation, or miscellaneous material. Surfacing material is anything that is sprayed or troweled onto a surface; thermal system insulation is material used to insulate HVAC pipes, tanks, etc., and miscellaneous material is any other type of material.
A homogeneous area is defined as an area of surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color and texture. A homogeneous area is not limited to only a room but can be found in several rooms. Sample selection in the building was determined by identifying the homogeneous areas and basing sampling locations upon these areas.
In conducting the building inspection in compliance with local, state, and federal regulations, all suspected ACM which were accessible to the inspector, were either sampled to confirm the actual presence of asbestos or assumed to contain asbestos.
2.2 LABORATORY ANALYSIS
Analysis was performed using Polarized Light Microscopy (PLM) with dispersion staining. The laboratory is rated proficient through National Institute of Standards and Technology- National Voluntary Laboratory Accreditation Program (NIST-NVLAP) for bulk asbestos analysis.
NESHAP defines ACM as containing more than 1% asbestos as determined using PLM (as specified in Appendix E, Subpart E, 40 CFR part 763, Section 1, Polarized Light Microscopy).
NESHAP defines friable ACM as any material containing more than 1% asbestos that, when dry, can be crumbled, pulverized or reduced to a powder by hand pressure. If the asbestos content of a friable material is less than ten (10) percent as determined by a method other than point counting by PLM, the client may elect to verify the asbestos content by point counting using PLM.
Because of the inherent limitations of PLM bulk sample analysis, any friable sample reported as <2% asbestos by PLM was automatically analyzed by the PLM point count method to determine whether it may be regulated under the asbestos NESHAP.
AirQuest Project #15671 3 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
Estimates of quantities of ACM were based upon the identification of suspect materials. Where suspect ACM were located behind walls, above ceilings, beneath carpeting, or other concealed conditions and the quantities cannot be verified, the estimate is based upon the conditions present during the survey. These estimates are not to be considered absolute and should be verified when the ACM is exposed.
2.3 SUSPECT ASBESTOS-CONTAINING MATERIALS
Homogenous areas (HA) of suspect material were identified and samples were collected and submitted under chain of custody to EMSL Analytical, Inc. (“EMSL”) for laboratory analysis of asbestos by PLM. If identified, friable samples with <2% asbestos were further analyzed by the PLM point count method to confirm the PLM results. A copy of the laboratory report and chain of custody record is included in Appendix IV.
Sample descriptions and laboratory results are summarized in Table 2. Photographs of each HA are included in Appendix V. A diagram illustrating the location of ACM is also provided in Appendix V.
Table 2 – Asbestos Laboratory Analysis and Summary
HA Sample Number
Description of Suspect Material
Location Asbestos Content %
1 164-1 2’ x 2’ White Ceiling – ACT Dots 37 West ND
1 164-2 2’ x 2’ White Ceiling – ACT Dots 36 West ND
1 164-3 2’ x 2’ White Ceiling – ACT Dots 49 Center ND
1 164-4 2’ x 2’ White Ceiling – ACT Dots 56 Northeast ND
1 164-5 2’ x 2’ White Ceiling – ACT Dots 43 Center ND
1 164-6 2’ x 2’ White Ceiling – ACT Dots 51 Center ND
1 164-7 2’ x 2’ White Ceiling – ACT Dots 18 North ND
2 164-8 2’ x 2’ White Ceiling – ACT Chicken Feet 33 North ND
2 164-9 2’ x 2’ White Ceiling – ACT Chicken Feet 33 South ND
2 164-10 2’ x 2’ White Ceiling – ACT Chicken Feet 33 Center ND
3 164-11 2’ x 2’ White Ceiling – ACT Gypsum 41 South ND
3 164-12 2’ x 2’ White Ceiling – ACT Gypsum 57 South ND
3 164-13 2’ x 2’ White Ceiling – ACT Gypsum 41 Center ND
AirQuest Project #15671 4 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
HA Sample Number
Description of Suspect Material
Location Asbestos Content %
4 164-14 Knockdown Drywall System
– Wall 53 South ND
4 164-15 Knockdown Drywall System
– Wall 55 North ND
4 164-16 Knockdown Drywall System
– Wall 49 Southeast ND
4 164-17 Knockdown Drywall System
– Wall 18 North ND
4 164-18 Knockdown Drywall System
– Wall 37 North ND
4 164-19 Knockdown Drywall System
– Wall 45 Northwest ND
4 164-20 Knockdown Drywall System
– Wall 51 West ND
5 164-21 4” x 4” Beige Ceramic Tile – Wall 41 Southeast ND
5 164-22 4” x 4” Beige Ceramic Tile – Wall 22 East ND
6 164-23 Drywall System - Wall 33 North ND
6 164-24 Drywall System - Wall 19 Northeast ND
6 164-25 Drywall System - Wall 54 Southeast ND
7 164-26 Yellow Carpet Mastic – Floor 51 South ND
7 164-27 Yellow Carpet Mastic – Floor 50 South Tan Mastic: ND
Black Mastic: 7% Chrysotile
7 164-28 Yellow Carpet Mastic – Floor 33 Center Tan Mastic: ND
Black Mastic: 5% Chrysotile
7 164-29 Yellow Carpet Mastic – Floor 20 East ND
7 164-30 Yellow Carpet Mastic – Floor 45 Southwest ND
8 164-31 8” x 8” Gray Ceramic Tile - Floor 41 Southeast ND
8 164-32 8” x 8” Gray Ceramic Tile - Floor 41 Southeast ND
9 164-33 12” x 12” Tan Vinyl Tile - Floor 53 South
Tile: ND Tan Mastic: ND
Black Mastic: 5% Chrysotile
AirQuest Project #15671 5 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
HA Sample Number
Description of Suspect Material
Location Asbestos Content %
9 164-34 12” x 12” Tan Vinyl Tile - Floor 53 North
Tile: ND Tan Mastic: ND
Black Mastic: 3% Chrysotile
10 164-35 12” x 12” Dark Gray Ceramic Tile - Floor 37 North ND
10 164-36 12” x 12” Dark Gray Ceramic Tile - Floor 18 Southeast ND
11 164-37 6” Gray Vinyl Base Cove 53 South ND
11 164-38 6” Gray Vinyl Base Cove 33 North ND
12 164-39 4” Gray Vinyl Base Cove 50 North ND
12 164-40 4” Gray Vinyl Base Cove 51 North ND
13 164-41 White Interior Door Caulk 33 East ND
13 164-42 White Interior Door Caulk 37 West ND
14 164-43 White A/C Duct Mastic 49 Center ND
14 164-44 White A/C Duct Mastic 51 Center ND
15 164-45 4” Glassrock TSI Straight Line 53 South ND
15 164-46 4” Glassrock TSI Straight Line 41 West ND
15 164-47 4” Glassrock TSI Straight Line 18 North ND
15 164-48 4” Glassrock TSI Straight Line 38 South ND
15 164-49 4” Glassrock TSI Straight Line 38 North ND
16 164-50 12” x 12” Tan Ceramic Tile - Floor 22 Northwest ND
16 164-51 12” x 12” Tan Ceramic Tile - Floor 22 Northwest ND
17 164-52 Gray A/C Duct Mastic 38 Center ND
17 164-53 Gray A/C Duct Mastic 38 Center ND
18 164-54 Concrete Block - Wall 38 West ND
18 164-55 Concrete Block - Wall 38 West ND
18 164-56 Concrete Block - Wall Exterior West ND
18 164-57 Concrete Block - Wall Exterior West ND
AirQuest Project #15671 6 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
HA Sample Number
Description of Suspect Material
Location Asbestos Content %
18 164-58 Concrete Block - Wall Exterior East ND
19 164-59 Concrete Slab - Floor Exterior West ND
19 164-60 Concrete Slab - Floor Exterior South ND
19 164-61 Concrete Slab - Floor Exterior East ND
19 164-62 Concrete Slab - Floor 38 West ND
19 164-63 Concrete Slab - Floor 38 North ND
20 164-64 Brown Exterior Floor Expansion Material Exterior East ND
20 164-65 Brown Exterior Floor Expansion Material Exterior South ND
20 164-66 Brown Exterior Floor Expansion Material Exterior North ND
20 164-67 Brown Exterior Floor Expansion Material Exterior North ND
21 164-68 Tan Interior Door Caulk 38 West 3% Chrysotile
21 164-69 Tan Interior Door Caulk 38 West 2% Chrysotile
22 164-70 Built Up Tar and Gravel - Roof Interior Roof West ND
22 164-71 Built Up Tar and Gravel - Roof Interior Roof North ND
22 164-72 Built Up Tar and Gravel - Roof Interior Roof North ND
22 164-73 Built Up Tar and Gravel - Roof
Interior Roof Center ND
22 164-74 Built Up Tar and Gravel - Roof
Interior Roof Center ND
23 164-75 Roll – on Asphalt Curb Vent - Roof Interior Roof West ND
23 164-76 Roll – on Asphalt Curb Vent - Roof Interior Roof West ND
23 164-77 Roll – on Asphalt Curb Vent - Roof Interior Roof North ND
23 164-78 Roll – on Asphalt Curb Vent - Roof
Interior Roof Center ND
23 164-79 Roll – on Asphalt Curb Vent - Roof
Interior Roof Center ND
24 164-80 Drywall at Interior Roof Interior Roof Center ND
AirQuest Project #15671 7 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
HA Sample Number
Description of Suspect Material
Location Asbestos Content %
24 164-81 Drywall at Interior Roof Interior Roof Center ND
24 164-82 Drywall at Interior Roof Interior Roof West ND
24 164-83 Drywall at Interior Roof Interior Roof North ND
24 164-84 Drywall at Interior Roof Interior Roof North ND
25 164-85 Yellow Spray on Foam at Interior Roof Ceiling Interior Roof West ND
25 164-86 Yellow Spray on Foam at Interior Roof Ceiling Interior Roof West ND
25 164-87 Yellow Spray on Foam at Interior Roof Ceiling Interior Roof North ND
25 164-88 Yellow Spray on Foam at Interior Roof Ceiling Interior Roof South ND
25 164-89 Yellow Spray on Foam at Interior Roof Ceiling Interior Roof East ND
26 164-90 Transite Panel at Interior Roof Deck Underside
Interior Roof Center 12% Chrysotile
26 164-91 Transite Panel at Interior Roof Deck Underside
Interior Roof Center 12% Chrysotile
26 164-92 Transite Panel at Interior Roof Deck Underside
Interior Roof Center 15% Chrysotile
27 164-93 Gray Metal Roof Seam Mastic Roof North ND
27 164-94 Gray Metal Roof Seam Mastic Roof West ND
27 164-95 Gray Metal Roof Seam Mastic Roof East ND
28 164-96 Gray Roof – Penetration Mastic Roof Center ND
28 164-97 Gray Roof – Penetration Mastic Roof Center ND
29 164-98 Brown Gasket Interior Roof Center ND
29 164-99 Brown Gasket Interior Roof Center ND
30 164-100 Red Gasket Interior Roof Center ND
30 164-101 Red Gasket Interior Roof Center ND
HA- Homogenous Area ND – None Detected ACT- Acoustical Ceiling Tile A/C- Air Conditioner TSI- Thermal System Insulation
AirQuest Project #15671 8 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
3 LEAD BASED PAINT SCREENING
An inspection was conducted to screen for the existence of lead containing painted building components. Testing of the painted building components was performed using an XRF Spectrometer. The XRF is a screening instrument currently recommended by the US Department of Housing and Urban Development (HUD) for analysis of lead levels in paint. The screening was used to assist in determining the need and relative concentrations of lead on painted building components for purposes of designing a sampling scheme for a composite waste stream analysis and demolition contractor worker protection information. The screening was not intended to be a lead-based paint survey in accordance with HUD guidelines. A summary of the screening results is included in Table 3.
Table 3 - Lead Based Paint Screening Information
Structure Color Substrate Location Results1 Pb (mg/cm2)
Wall Beige Concrete Exterior Negative 0.1 Wall Beige Concrete Exterior Negative 0.1 Wall Beige Concrete Exterior Negative 0.0 Wall Brown Concrete Exterior Negative 0.1 Wall Brown Concrete Exterior Negative 0.0 Wall White Drywall Hallway Negative -0.2 Wall Gray Drywall Hallway Negative 0.1 Wall Gray Drywall Office Negative 0.1 Wall Gray Drywall Office Negative -0.1 Door Gray Metal Office Negative -0.1
Pb - Lead mg/cm2 – milligrams per square centimeter 1Indicates if the material meets the Department of Housing and Urban Development definition of Lead Based Paint
4 TCLP RCRA METALS
A waste stream composite sample was collected from the building for laboratory analysis of TCLP RCRA-8 Metals.
4.1 TCLP SAMPLE COLLECTION
The sample composition was determined by the composition of the materials comprising the building. Each major building component (such as wood, metal, concrete, glass, etc.) was estimated as a percentage of the weight of the building whole. Once the composition of the building was estimated, representative samples were collected of each material, in an approximate weight proportion as shown in Table 4.
AirQuest Project #15671 9 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
Table 4 - Waste Stream Composition
Waste Stream Component Percentage of
Waste Concrete 70
Metal 5 Wood 5
Drywall 15 Miscellaneous Metal 5
Total Percentage 100
4.2 TCLP SAMPLE RESULTS
The samples were submitted under chain of custody to Spectrum Environmental Laboratories (“Spectrum”), a National Environmental Laboratory Accreditation Conference (NELAC) accredited laboratory, for analysis of TCLP-RCRA-8 Metals by EPA via 1311/6010C/7470A. The results are summarized in Table 5.
Table 5 – Toxicity Characteristic Leachate Procedure Results
Sample TCLP Results (milligrams/liter)
Arsenic Barium Cadmium Chromium Lead Mercury Selenium Silver 164-
ND 0.0950 ND ND ND ND ND ND
Limit1 5.0 100.0 1.0 5.0 5.0 0.2 1.0 5.0 1Regulatory Limit per 40 CFR 261.24 ND – None Detected
5 PCBs Samples for PCBs were collected in general accordance with the EPA Region 1 Standard Operating Procedure for Sampling Porous Surfaces for Polychlorinated Biphenyls (PCBs), May 2011.
The samples were collected from representative painted surfaces to include up to a half-inch of the substrate. The samples were submitted under chain of custody to Spectrum for analysis by EPA Method SW 846 3540C/8020A.
Table 6 – PCB Results
Sample Results (mg/kg)
Aroclor-
Aroclor-
Aroclor-
Aroclor-
Aroclor-
Aroclor-
Aroclor-
164-001 Concrete ND ND ND ND ND ND ND
164-002 Paint ND ND ND ND ND ND ND 1Regulatory Limit per 40 CFR 761.50 Subpart D is 50 mg/kg mg/kg – milligrams/kilogram ND – None Detected
AirQuest Project #15671 10 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
6 OTHER REGULATED MATERIALS INVENTORY
AirQuest conducted another regulated/hazardous materials inventory in general accordance with the Recommended Management Practices for the Removal of Hazardous Materials from Buildings Prior to Demolition prepared by the University of Florida and sponsored by the Florida Department of Environmental Protection, 1999. The inventory included lamps, thermostats, and light switches potentially containing mercury; exit signs, emergency lights, and smoke alarms that have batteries; lighting ballasts which contain polychlorinated biphenyls (PCBs); transformers;
freon, hazardous chemicals and petroleum products; and lead pipes and roof vent flashings.
Certain assumptions for the inspection of fluorescent light ballasts for PCBs were utilized for the building inspections to be completed in a timely and cost-effective manner. As required by regulation, lighting ballasts must not contain PCBs and the label on the ballast must state “No PCB”. AirQuest inventoried 100% of the fluorescent lighting fixtures and inspected a representative of each type of fixture (i.e. 2-foot, 4-foot, etc.) for the “No PCB” labeling.
Each exit sign and emergency lights were presumed to each contain a single lead-acid rechargeable battery. Quantities and types of any ORM found are summarized in Table 7.
Table 7 – Other Regulated Materials Inventory
ORM Component
Type/Location
Quantity
Photographs
Recyclables
Fluorescent Bulbs 24" Lamp 6
Fluorescent Bulbs 48" Lamp 148
AirQuest Project #15671 11 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
Fluorescent Bulbs Compact Bulbs 1
Fluorescent Bulbs U-Shaped Bulb 28
Light Ballasts In 24" Fluorescent Fixtures
Light Ballasts In 48" Fluorescent Fixtures
AirQuest Project #15671 12 Building 164 Pre-Demolition
Lead-Acid Rechargeable Batteries
In Exit Signs 7
Lead-Acid Rechargeable Batteries
At Fire and Security Systems (12v)
Thermostats Digital - No Mercury Observed
Fire Pull-Down System
AirQuest Project #15671 13 Building 164 Pre-Demolition
Printer & Toner 34
Cleaning Supplies 6
Air Compressor Tanks
Specialized ORM
Freon In A/C Units 4
AirQuest Project #15671 14 Building 164 Pre-Demolition
Freon In Drinking
Fountains
Freon Refrigerator Units 8
Transformers Exterior Pad Mounted
AirQuest Project #15671 15 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
ORM Component Type/Location Quantity Photographs
Fire Extinguishers 3
Emergency Lights Interior 2
Emergency Lights Exterior 12
7 SOIL TESTING FOR ORGANOCHLORINE PESTICIDES
AirQuest advanced four (4) soil borings and collected two (2) samples at each boring location at depths of zero to six inches (0 - 6 in.) and eighteen to twenty-four inches (18 – 24 in.) below land surface using a properly decontaminated hand bucket auger. The samples were generally collected near the four corners of the building as shown in Appendix II.
The soil sampling was conducted in accordance with Florida Department of Environmental Protection (FDEP) Standard Operating Procedures SOP-001-01 FS 3000 (Soil) and SOP-001-01 FQ1000 (Field Quality Control Requirements). One boring log was completed for each building
AirQuest Project #15671 16 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing location documenting the observed lithology, visually estimated moisture content, noticeable odors, soil color, sample collection times, sampler’s name, sampling interval and boring completion method. The soil boring log and soil boring location photographs are included in Appendix VIII.
Samples were placed in dedicated sample containers provided by the laboratory and labeled according to the referenced building/structure, collection time, sampler’s name and analysis. A chain of custody form was completed to document the chronology of ownership, control and transfer of the samples. All samples were placed in a cooler filled with ice for transfer to the laboratory.
The soil samples were shipped to Eurofins TestAmerica (“TestAmerica”) in Pensacola, Florida, a NELAC accredited environmental laboratory licensed in the State of Florida, for analysis by EPA Method 8081B (Organochlorine Pesticides by GC). Analytical results are summarized in Table
8. A copy of the laboratory report and chain of custody record is included in Appendix IX.
The analytical results indicate traces of OCPs 4,4’-DDE, 4,4’-DDT, Dieldrin, and Total Chlordane above the laboratory method detection limit and some above the practical quantitation limit, in many of the soil samples. The detected concentrations do not exceed the Commercial/Industrial or Residential Soil Cleanup Target Levels (SCTLs) provided in Chapter 62-777, FAC the criteria used by the FDEP.
8 CONCLUSIONS AND RECOMMENDATIONS
A thorough pre-demolition inspection for asbestos and hazardous materials was conducted at the site and an inventory of the materials was created. The soils surrounding the site were sampled and analyzed for pesticides. Based upon the results of the inspections, recommendations for each contaminant are discussed separately below.
8.1 ASBESTOS CONCLUSIONS AND RECOMMENDED RESPONSE ACTION
Table 9 summarizes the results of our observation and laboratory analysis of identified ACM.
AirQuest Project #15671 17 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
Table 8 – Soil Sample Analytical Results
Sample Sample Depth (Inches)
Results (mg/kg)
4,4’-DDE 4,4’-DDT Dieldrin Total Chlordane
OCP-164.1 0-6 ND ND 0.023 ND
OCP-164.2 18-24 ND ND 0.025 ND
OCP-164.3 0-6 0.0030I ND 0.0061I ND
OCP-164.4 18-24 ND ND ND ND
OCP-164.5 0-6 ND ND ND ND
OCP-164.6 18-24 ND ND ND ND
OCP-164.7 0-6 0.0018 0.0014I 0.0045I 0.00080I
OCP-164.8 18-24 0.00052I ND ND ND
SCTL (Commercial/Industrial) 15 15 0.3 14
SCTL (Residential) 2.9 2.9 0.06 2.8 mg/kg – milligrams/kilogram ND – None Detected by Method Detection Limit SCTL – Soil Cleanup Target Level, Chapter 62-777 Florida Administrative Code I – The Reported Value is Between the Laboratory Method Detection Limit and the Laboratory Practical Quantitation Limit
AirQuest Project #15671 18 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
Table 9 - Asbestos Containing Materials
Homogenous Area (HA) Material
Percentage/ Type
Material Condition/ Friability
Approximate Quantity1 Category
HA 7:
Yellow Floor Carpet Mastic
Tan Mastic: ND Black Mastic: 5-7% Chrysotile
Good/ Non-Friable 8,566 SF Category I
NESHAPs
HA 9:
12”x12” Tan Floor Vinyl Tile
Tile: ND Tan Mastic: ND Black Mastic: 3-5% Chrysotile
Good/ Non-Friable 112 SF Category I
NESHAPs
HA 21:
Tan Interior Door Caulk
2-3% Chrysotile Good/ Non-Friable 24 LF Category II
NESHAPs
HA 26:
Transite Panel at Interior Roof Deck Underside
12-15% Chrysotile Good/ Non-Friable 216 SF Category II
NESHAPs
1Note: Quantities were updated from original estimates based upon field verification of the location of the material for purposes of creating the ACM location diagram provided in Appendix IV.
LF- Linear Feet ND- None Detected NESHAP– National Emissions Standard for Hazardous Air Pollutants Non-Friable- Material that, when dry, may not be crumbled, pulverized, or reduced to powder by hand pressure.
SF- Square Feet
National Emission Standards for Hazardous Air Pollutants (NESHAP) Category Recommendations:
• Category I: Category I nonfriable ACM refers to asbestos-containing packing, gaskets, resilient floor coverings, and asphalt roofing products.
o Demolition Activities: NESHAP regulations do not require that Category I nonfriable ACM be removed prior to demolition activities as long as the material is not rendered friable by demolition practices, kept wet during demolition activities, is segregated from the waste stream and disposed of in a Class I landfill capable of accepting such material.
The demolition crew must abide by OSHA regulations pertaining to asbestos exposure. The owner should consider removal prior to demolition as this may be more cost-effective than complying with OSHA regulations, the costs associated with segregating the waste stream and the additional disposal costs.
Prior to the removal or in-place wet demolition of the identified asbestos containing material, notification to the appropriate County and the State of Florida agencies is required.
AirQuest Project #15671 19 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing
• Category II: Category II nonfriable ACM refers to any material that is not classified under Category I.
o Demolition Activities: NESHAP regulations do not require that Category II nonfriable ACM be removed prior to demolition activities if the probability is low that the materials will not become crumbled, pulverized, or reduced to powder during demolition. However, many Category II materials (for example, transite panels) will become RACM during demolition activities and most NESHAP regulators require removal prior to demolition. Prior regulatory approval is needed if Category II nonfriable materials will remain in place during the demolition.
Category II nonfriable ACM that will remain in place during demolition must be kept wet during demolition activities, segregated from the waste stream and disposed of in a Class I landfill capable of accepting such material. The demolition crew must abide by OSHA regulations pertaining to asbestos exposure. The owner should consider removal prior to demolition as this may be more cost-effective than complying with OSHA regulations, the costs associated with segregating the waste stream and the additional disposal costs.
Prior to the removal or in-place wet demolition of Category II nonfriable material, notification to the appropriate County and the State of Florida agencies is required.
• Special Considerations for Mastic on Concrete: AirQuest recommends that if the concrete slabs will be recycled during the demolition process, formal asbestos remediation oversight be performed during the removal of all asbestos containing mastics from the concrete slabs. It is common that remediation will remove the thick, three dimensional “easily remediated” mastic layer and that patches of residual mastic remain in the cracks, corners and depressions in the concrete. AirQuest recommends oversight and proper documentation during the mastic remediation process to avoid any potential delays or liability with the recycling contractors.
8.2 LEAD SCREENING & OSHA LEAD GUIDANCE
Lead was identified in the paint at the site. Under the present OSHA lead construction standard, all identified lead-containing materials affected by construction activities falls under the requirements of 29 CFR 1926. There are no current government guidelines defining a lead-based paint or lead concentration that creates a hazardous atmosphere when disturbed. Based on current OSHA guidelines, for those employees who will be disturbing lead-containing paint (LCP), their employer must make an initial determination by monitoring employee exposure if any employee is exposed to lead at or above 30 micrograms per cubic meter for an eight-hour time weighted average (30 µg/m3 8-hour time weighted average). The employer must implement OSHA prescribed protective measures until they can demonstrate that the employee exposure is not in excess of the action level.
In general, relatively low levels of lead were detected in the various coated surfaces surveyed.
Depending on the degree and type of disturbance of these surfaces (i.e. sanding, cutting, or demolishing), employers may be required to implement varying degrees of OSHA prescribed protective measures. These protective measures must be maintained until it can be demonstrated
AirQuest Project #15671 20 Building 164 Pre-Demolition W912DY-19-P-0053 Asbestos, Hazardous Materials & Soil Testing that employee exposures do not exceed the action level. The employer should also implement and maintain a written compliance program detailing the protective measures they will utilize to control lead exposure during renovation activities.
8.3 TCLP RCRA METALS / LEAD
The results of the laboratory analysis indicate that the waste stream generated from the site is non-hazardous.
8.4 PCBS
The results of the sampling and analysis did not identify PCBs in composite waste stream paint and concrete samples.
8.5 OTHER REGULATED MATERIALS
In general, the items inventoried may be recycled and reclaimed. Special disposal considerations may be required for the transformer.
8.6 SOIL CONCLUSIONS
The soil analytical results did not identify EPA Method 8081B compounds above the state of Florida Commercial/Industrial or Residential SCTLs.
9 LIMITATIONS
If any suspect hazardous/asbestos containing building materials are encountered during demolition activities that were not sampled in this report, the materials should not be disturbed until they have been sampled and identified as non-hazardous and non-ACM through appropriate investigation and/or laboratory analysis. Many of the roofs at Tyndall Air Force Base were sealed with an EPDM roofing system covering all the original roofing materials. It is possible, if not likely, that additional suspect asbestos materials are present under the EPDM and were not identified during the asbestos survey.
This report was prepared in a manner consistent with that level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions. This report was prepared for the exclusive use of the client and assigned agents and is not intended for any other purposes. Our report is based on the information available to us at the time of our investigation and limited in scope to the stated purpose and/or the area(s) inspected. Other conditions elsewhere in the site may differ from those in the inspected/ surveyed locations and such conditions are unknown, may change over time, and/or have not been considered. This report does not claim to identify all potential hazards and/or contaminants that may be present, nor does it imply any medical opinion on the relationship of potential health effects with any reported hazards and/ or contaminants. Our opinions are based on our findings and professional expertise, with no guaranty or warranty implied herein. Should additional information become available, we reserve the right to determine the impact, if any, of the new information on our opinions, conclusions, and recommendations if necessary, as warranted by the discovery of the additional information. AirQuest accepts no responsibility for interpretation of this report by others. Its contents shall not be used or relied upon by other parties without prior written authorization by AirQuest.
Appendix I Certifications
JONATHAN ZACHEM, SECRETARYRICK SCOTT, GOVERNOR
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
ASBESTOS LICENSING UNIT
THE ASBESTOS CONSULTANT HEREIN IS LICENSED UNDER THE
PROVISIONS OF CHAPTER 469, FLORIDA STATUTES
BOYLE, TRACI-ANNE
Do not alter this document in any form.
AIRQUEST ENVIRONMENTAL INC
LICENSE NUMBER: AX60
EXPIRATION DATE: NOVEMBER 30, 2020
This is your license. It is unlawful for anyone other than the licensee to use this document.
6851 SW 45 ST
DAVIE FL 33314
Always verify licenses online at MyFloridaLicense.com https://www.myfloridalicense.com/LicenseDetail.asp?SID=&id=8c21d1d6249bcaa3338cefa039457259
JONATHAN ZACHEM, SECRETARYRICK SCOTT, GOVERNOR
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
BOARD OF PROFESSIONAL GEOLOGISTS
THE PROFESSIONAL GEOLOGIST HEREIN IS LICENSED UNDER THE
PROVISIONS OF CHAPTER 492, FLORIDA STATUTES
SMITH, TED J
Do not alter this document in any form.
1735 CLARENDON AVENUE
LICENSE NUMBER: PG1368
EXPIRATION DATE: JULY 31, 2020
This is your license. It is unlawful for anyone other than the licensee to use this document.
LAKELAND FL 33803
Always verify licenses online at MyFloridaLicense.com https://www.myfloridalicense.com/LicenseDetail.asp?SID=&id=6b0348687cc372fc3b319e7b329b1312
Appendix II Sample Location Diagrams
Sampling Locations
LEGEND
ASBESTOS SAMPLE # 1
PCB PAINT COMPOSITE P
PCB CONCRETE COMPOSITE C
SOIL BORING LOCATION 1
Contract
FACILITIES REDUCTION PROGRAM
FY19 TYNDALL II
W912DY-19-P-0053
DATE: MARCH 2020
Site
TYNDALL AIR FORCE BASE
FLORIDA
BUILDING: 95 FS OPS
BUILDING #: 164
6851 SW 45TH STREET
FT. LAUDERDALE, FLORIDA 33314
AIRQUEST PROJECT 15671
Appendix III Structure Demolition Overview Diagram, Aerial
Photographs and Demolition Overview Photographs
Demolition Overview
BUILDING INFORMATION
NAME 95 FS OPS
NUMBER 164
YEAR BUILT 1961
SQUARE FEET 14,322
STORIES 1
W912DY-19-P-0053
DATE: MARCH 2020
Site
TYNDALL AIR FORCE BASE
FLORIDA
Overview
Bld 164 - 95 FS OPS Tyndall Air Force Base
AirQuest Environmental, Inc.
Project #15671
Exterior
Overview
Tyndall Air Force Base
AirQuest Environmental, Inc.
Interior
Appendix IV Asbestos Laboratory Report and Chain of Custody Record
EMSL Analytical, Inc.
19501 NE 10th Ave. Bay A N. Miami Beach, FL 33179
Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com
171908881EMSL Order:
Customer ID: AQE63
Customer PO:
Project ID:
Attention: Phone:Paul LeBlanc (954) 214-2640
Fax:AirQuest Environmental, Inc. (954) 792-2221
Received Date:6851 Southwest 45th Street 12/06/2019 11:44 AM
Analysis Date:Fort Lauderdale, FL 33314 12/09/2019 - 12/10/2019
Collected Date: 12/04/2019
Project: Tyndall AFB - 15671 - 164
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
164-1
171908881-0001
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
40%
30%
Tan/White
Fibrous
Heterogeneous
Ceiling Tile
164-2
171908881-0002
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
40%
30%
Tan/White
Fibrous
Heterogeneous
Ceiling Tile
164-3
171908881-0003
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
40%
30%
White/Black
Fibrous
Heterogeneous
Ceiling Tile
164-4
171908881-0004
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
40%
30%
Tan/White
Fibrous
Heterogeneous
Ceiling Tile
164-5
171908881-0005
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
40%
30%
Tan/White
Fibrous
Heterogeneous
Ceiling Tile
164-6
171908881-0006
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
40%
30%
Tan/White
Fibrous
Heterogeneous
Ceiling Tile
164-7
171908881-0007
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
40%
30%
Tan/White
Fibrous
Heterogeneous
Ceiling Tile
164-8
171908881-0008
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
30%
40%
Tan/White
Fibrous
Heterogeneous
Ceiling Tile
164-9
171908881-0009
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
30%
40%
Tan/White
Fibrous
Heterogeneous
Ceiling Tile
164-10
171908881-0010
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
40%
30%
Tan/White
Fibrous
Heterogeneous
Ceiling Tile
164-11
171908881-0011
None DetectedGypsum
Mica
Non-fibrous (Other)
65%
3%
22%
Cellulose
Glass
10%
<1%
White
Fibrous
Heterogeneous
Ceiling Tile
164-12
171908881-0012
None DetectedGypsum
Mica
Non-fibrous (Other)
65%
3%
22%
Cellulose
Glass
10%
<1%
White
Fibrous
Heterogeneous
Ceiling Tile
164-13
171908881-0013
None DetectedGypsum
Mica
Non-fibrous (Other)
65%
3%
22%
Cellulose
Glass
10%
<1%
Tan/White
Fibrous
Heterogeneous
Ceiling Tile
164-14-Drywall
171908881-0014
None DetectedGypsum
Mica
Non-fibrous (Other)
65%
5%
20%
Cellulose10%Brown/White
Fibrous
Heterogeneous
Drywall System
164-14-Joint Compound
171908881-0014A
None DetectedCa Carbonate
Non-fibrous (Other)
15%
85%
White
Non-Fibrous
Homogeneous
Drywall System
164-15-Drywall
171908881-0015
None DetectedGypsum
Non-fibrous (Other)
65%
25%
Cellulose
Glass
10%
<1%
White
Fibrous
Heterogeneous
Drywall System
Initial report from: 12/11/2019 07:49:40
Page 1 of 9ASB_PLM_0008_0001 - 1.78 Printed: 12/11/2019 7:49 AM
Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com
171908881EMSL Order:
Customer ID: AQE63
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
164-15-Joint Compound
171908881-0015A
None DetectedCa Carbonate
Non-fibrous (Other)
15%
85%
White
Non-Fibrous
Homogeneous
Drywall System
164-16-Drywall
171908881-0016
None DetectedGypsum
Non-fibrous (Other)
65%
25%
Cellulose
Glass
10%
<1%
White
Fibrous
Heterogeneous
Drywall System
164-16-Joint Compound
171908881-0016A
None DetectedCa Carbonate
Non-fibrous (Other)
15%
85%
White
Non-Fibrous
Homogeneous
Drywall System
164-17-Drywall
171908881-0017
None DetectedGypsum
Non-fibrous (Other)
65%
25%
Cellulose
Glass
10%
<1%
White
Fibrous
Heterogeneous
Drywall System
164-17-Joint Compound
171908881-0017A
None DetectedCa Carbonate
Non-fibrous (Other)
15%
85%
White
Non-Fibrous
Homogeneous
Drywall System
164-18-Drywall
171908881-0018
None DetectedGypsum
Non-fibrous (Other)
65%
25%
Cellulose
Glass
10%
<1%
White
Fibrous
Heterogeneous
Drywall System
164-18-Joint Compound
171908881-0018A
None DetectedCa Carbonate
Non-fibrous (Other)
15%
85%
White
Non-Fibrous
Homogeneous
Drywall System
164-19-Drywall
171908881-0019
None DetectedGypsum
Non-fibrous (Other)
65%
25%
Cellulose
Glass
10%
<1%
Tan/White
Fibrous
Heterogeneous
Drywall System
164-19-Joint Compound
171908881-0019A
None DetectedCa Carbonate
Non-fibrous (Other)
15%
85%
White
Non-Fibrous
Homogeneous
Drywall System
164-20-Drywall
171908881-0020
None DetectedGypsum
Non-fibrous (Other)
65%
25%
Cellulose
Glass
10%
<1%
Tan/White
Fibrous
Heterogeneous
Drywall System
164-20-Joint Compound
171908881-0020A
None DetectedCa Carbonate
Non-fibrous (Other)
15%
85%
White
Non-Fibrous
Homogeneous
Drywall System
164-21-Ceramic Tile
171908881-0021
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Ceramic Tile
164-21-Grout
171908881-0021A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
10%
15%
75%
Beige
Non-Fibrous
Homogeneous
Ceramic Tile
164-21-Thinset
171908881-0021B
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
30%
10%
60%
White
Non-Fibrous
Homogeneous
Ceramic Tile
164-22-Ceramic Tile
171908881-0022
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Ceramic Tile
164-22-Grout
171908881-0022A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
30%
15%
55%
Beige
Non-Fibrous
Homogeneous
Ceramic Tile
164-22-Thinset
171908881-0022B
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
30%
15%
55%
White
Non-Fibrous
Homogeneous
Ceramic Tile
164-23-Drywall
171908881-0023
None DetectedGypsum
Non-fibrous (Other)
65%
25%
Cellulose
Glass
10%
<1%
White
Fibrous
Heterogeneous
Drywall System
164-23-Joint Compound
171908881-0023A
None DetectedCa Carbonate
Non-fibrous (Other)
15%
85%
White
Non-Fibrous
Homogeneous
Drywall System
Page 2 of 9ASB_PLM_0008_0001 - 1.78 Printed: 12/11/2019 7:49 AM
Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com
171908881EMSL Order:
Customer ID: AQE63
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
164-24-Drywall
171908881-0024
None DetectedGypsum
Non-fibrous (Other)
65%
25%
Cellulose
Glass
10%
<1%
White
Fibrous
Heterogeneous
Drywall System
164-24-Joint Compound
171908881-0024A
None DetectedCa Carbonate
Non-fibrous (Other)
15%
85%
White
Non-Fibrous
Homogeneous
Drywall System
164-25-Drywall
171908881-0025
None DetectedGypsum
Non-fibrous (Other)
65%
25%
Cellulose
Glass
10%
<1%
Tan/White
Fibrous
Heterogeneous
Drywall System
164-25-Joint Compound
171908881-0025A
None DetectedCa Carbonate
Non-fibrous (Other)
15%
85%
White
Non-Fibrous
Homogeneous
Drywall System
164-26
171908881-0026
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Carpet Mastic
164-27-Tan Mastic
171908881-0027
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Carpet Mastic
164-27-Black Mastic
171908881-0027A
7% ChrysotileNon-fibrous (Other)93%Black
Non-Fibrous
Homogeneous
Carpet Mastic
164-28-Tan Mastic
171908881-0028
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Carpet Mastic
164-28-Black Mastic
171908881-0028A
5% ChrysotileNon-fibrous (Other)95%Black
Non-Fibrous
Homogeneous
Carpet Mastic
164-29
171908881-0029
None DetectedNon-fibrous (Other)100%Tan/Black
Non-Fibrous
Homogeneous
Carpet Mastic
164-30
171908881-0030
None DetectedNon-fibrous (Other)100%Tan/Black
Non-Fibrous
Homogeneous
Carpet Mastic
164-31-Ceramic Tile
171908881-0031
None DetectedNon-fibrous (Other)100%Brown
Non-Fibrous
Homogeneous
Ceramic Tile
164-31-Thinset
171908881-0031A
None DetectedCa Carbonate
Non-fibrous (Other)
15%
85%
White
Non-Fibrous
Homogeneous
Ceramic Tile
164-32-Ceramic Tile
171908881-0032
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Ceramic Tile
164-32-Thinset
171908881-0032A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
30%
15%
55%
White
Non-Fibrous
Homogeneous
Ceramic Tile
164-33-Floor Tile
171908881-0033
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
Vinyl Tile
164-33-Tan Mastic
171908881-0033A
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Vinyl Tile
164-33-Black Mastic
171908881-0033B
5% ChrysotileNon-fibrous (Other)95%Black
Non-Fibrous
Homogeneous
Vinyl Tile
164-34-Floor Tile
171908881-0034
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
Vinyl Tile
Page 3 of 9ASB_PLM_0008_0001 - 1.78 Printed: 12/11/2019 7:49 AM
Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com
171908881EMSL Order:
Customer ID: AQE63
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
164-34-Tan Mastic
171908881-0034A
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Vinyl Tile
164-34-Black Mastic
171908881-0034B
3% ChrysotileNon-fibrous (Other)97%Black
Non-Fibrous
Homogeneous
Vinyl Tile
164-35-Ceramic Tile
171908881-0035
None DetectedNon-fibrous (Other)100%Brown/Gray
Non-Fibrous
Homogeneous
Ceramic Tile
164-35-Grout
171908881-0035A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
30%
15%
55%
Gray
Non-Fibrous
Homogeneous
Ceramic Tile
164-35-Thinset
171908881-0035B
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
15%
10%
75%
White
Non-Fibrous
Homogeneous
Ceramic Tile
164-36-Ceramic Tile
171908881-0036
None DetectedNon-fibrous (Other)100%Brown/Gray
Non-Fibrous
Homogeneous
Ceramic Tile
164-36-Grout
171908881-0036A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
30%
15%
55%
Gray
Non-Fibrous
Homogeneous
Ceramic Tile
164-36-Thinset
171908881-0036B
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
30%
15%
55%
White
Non-Fibrous
Homogeneous
Ceramic Tile
164-37-Cove Base
171908881-0037
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Vinyl Cove Base
164-37-Mastic
171908881-0037A
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Vinyl Cove Base
164-38-Cove Base
171908881-0038
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Vinyl Cove Base
164-38-Mastic
171908881-0038A
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Vinyl Cove Base
164-39-Cove Base
171908881-0039
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Vinyl Cove Base
164-39-Mastic
171908881-0039A
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Vinyl Cove Base
164-40-Cove Base
171908881-0040
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Vinyl Cove Base
164-40-Mastic
171908881-0040A
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Vinyl Cove Base
164-41
171908881-0041
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Caulk
164-42
171908881-0042
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Caulk
164-43
171908881-0043
None DetectedNon-fibrous (Other)96%Cellulose4%White
Non-Fibrous
Homogeneous
A/C Duct Mastic
Page 4 of 9ASB_PLM_0008_0001 - 1.78 Printed: 12/11/2019 7:49 AM
Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com
171908881EMSL Order:
Customer ID: AQE63
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
164-44
171908881-0044
None DetectedNon-fibrous (Other)97%Cellulose3%White
Non-Fibrous
Homogeneous
A/C Duct Mastic
164-45-Glassrock
171908881-0045
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
TSI
164-45-Mastic
171908881-0045A
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
TSI
164-46-Glassrock
171908881-0046
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
TSI
164-46-Mastic
171908881-0046A
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
TSI
164-47-Glassrock
171908881-0047
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
TSI
164-47-Mastic
171908881-0047A
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
TSI
164-47-Wrap
171908881-0047B
None DetectedNon-fibrous (Other)25%Cellulose
Glass
65%
10%
White/Silver
Fibrous
Homogeneous
TSI
164-48-Glassrock
171908881-0048
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
TSI
164-48-Wrap
171908881-0048A
None DetectedNon-fibrous (Other)25%Cellulose
Glass
65%
10%
White/Silver
Fibrous
Homogeneous
TSI
164-48-Black Mastic
171908881-0048B
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
TSI
164-48-White Mastic
171908881-0048C
None DetectedNon-fibrous (Other)92%Wollastonite8%White
Non-Fibrous
Homogeneous
TSI
164-49-Glassrock
171908881-0049
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
TSI
164-49-Mastic
171908881-0049A
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
TSI
164-50-Ceramic Tile
171908881-0050
None DetectedNon-fibrous (Other)100%Brown/Tan
Non-Fibrous
Homogeneous
Ceramic Tile
164-50-Grout
171908881-0050A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
30%
15%
55%
Tan
Non-Fibrous
Homogeneous
Ceramic Tile
164-51-Ceramic Tile
171908881-0051
None DetectedNon-fibrous (Other)100%Brown
Non-Fibrous
Homogeneous
Ceramic Tile
164-51-Grout
171908881-0051A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
30%
15%
55%
Tan
Non-Fibrous
Homogeneous
Ceramic Tile
164-52
171908881-0052
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
A/C Duct Mastic
Page 5 of 9ASB_PLM_0008_0001 - 1.78 Printed: 12/11/2019 7:49 AM
Tel/Fax: (305) 650-0577 / (305) 650-0578 http://www.EMSL.com / miamilab@emsl.com
171908881EMSL Order:
Customer ID: AQE63
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
164-53
171908881-0053
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
A/C Duct Mastic
164-54
171908881-0054
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
30%
15%
55%
Whi…