This document is a pump outline drawing for a federal contract opportunity. It provides detailed specifications and requirements for two low pressure pumps, including the pump model, dimensions, nozzle connections, weights, and foundation loads. The pumps are designated as Down River Raw Water Pumps DP-7 and DP-10 and are intended for low pressure screen backwash service. Key details include the pump model VIT-FF, discharge flange size of 8" 150# ASME RF, and maximum allowable working pressure of 85 PSIG. The drawing also includes an adjustable coupling, sacrificial anodes, and requirements for the driver, sole plate, and foundation. The related federal contract opportunity is for Dissolved Oxygen Vertical Turbine Pumps Refurbishment Services, to be performed for the U.S. Army Corps of Engineers.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
B
C
D
A
B
C
D
GOULDS PUMPS
3.75 95,3[ ] 2.40
61,0[ ]
0.75 19,1[ ]
0.75 19,1[ ]
R1.50 38,1[ ]
1.50 38,1[ ]
4.00 101,6[ ]
REF.6.00
152,4[ ]
TOTAL
PUMP LENGTH
358.56 9107,4[ ]
MIN.3.69
93,7[ ]
5.68 144,3[ ]
MIN.SUBMERGENCE
AT RATED FLOW
23.60 599,4[ ]
16.00 406,4[ ]
10.75 273,1[ ]
GROUT
2.00 50,8[ ]
1.75 44,5[ ]
4.75 120,7[ ]
RECOMMENDED
DRILLED HOLE
DIAMETER IS
0.88 MIN.
1.31 MAX.
LTR ZONE REVISION BY DATE
A1 - ADDED
SW 07-12-16
A2 - REVISED
B1 - ADDED NOTE 12,13 & 14
SW 12-08-16
B2 - ADDED GREASE LINES
C1 - REVISED SW 03-09-17
D - ADDED ANCHOR BOLT DETAIL SW 05-03-17
E1 - ADDED
SW 05-22-17
E2 - REVISED
F - REVISED SW 05-24-21
SHEET 1 OF 3
THIRD ANGLE
PROJECTION
FGAD315417
REVDRAWING
COPYRIGHT
APPROVED
CHECKED
S.W 03-02-16
DRAWN
HCL 03-02-16
DRAWING SCALE: NONE DIMENSIONS IN INCHES[MM]
PUMP OUTLINE DRAWING
MODEL VIT-FF
CUSTOMER: CDM CONSTRUCTORS INC.
GOULDS SERIAL NO.: 315417
PRODUCT NO: ----
CUSTOMER P.O. NO.: 110426.P.005
PUMP ITEM NO.: DOWN RIVER RAW WATER PUMPS DP-7 & DP-10
SERVICE: LOW PRESSURE SCREEN BACKWASH PUMPS
CUSTOMER DATA
07-12-16DATE:S.WEBSTERSIGNATURE:
CERTIFIED FOR CONSTRUCTION ONLY WHEN SIGNED.
FOR PERFORMANCE INFORMATION REFER TO DATA SHEET
STAGES:1SIZE:10X16BLC
2PUMP QTY:MODEL: VIT-FF
FOR DRIVER INFORMATION SEE DRIVER PRINT
NIDECMFR.
DRIVER SPECIFICATIONS
TYPE: TENSION PLATEMFR: ITT
SHAFT SEAL
NOXYESGUARD PROVIDED:
ADJUSTABLETYPE:
ITTMFR:
COUPLING SPECIFICATIONS
V I T F F
LIFTING LUG
-DETAIL-
A2
A1
A2
A2
PIT BOTTOM
A1SACRIFICIAL
ANODES ON
BOWL ASSEMBLY
T5
C1
C1
C1
ANCHOR BOLT
-DETAIL-
SUPPLIED BY CUSTOMER
SOLE PLATE
(2) WASHER
HEX NUT
D
RECOMMENDED SOLUTION
SIMPSON AT-XP + 7/8 316 SS
PER ASTM F593
OR EQUIVALENT 4 PLACES
E1
E2
SQ.
22.00 558,8[ ]
OPENING
19.00 482,6[ ]
4 PLACES
1.00 25,4[ ]
TYP.
11.00 279,4[ ]
SEE
NOTE 3
36.12 917,45[ ]
39.00 990,6[ ]
SEE
NOTE 6
SEE
NOTE 7
17.50 444,5[ ]
1.75 44,5[ ]
12.00 304,8[ ]
SQ.
25.00 635,0[ ]
TYP.
12.50 317,5[ ]
SOLE PLATE
-DETAIL-
DISCH.�q�
COUPLING GUARDS
(2) LIFTING LUGS
SEE NOTE 11
T4
T4
HEAD MOUNTING
FLANGE
T3
SEE NOTE 2 AND 5
PUMP ROTATION CCW
SEE SOLE PLATE
DETAIL
SEE DETAIL A
T1
CONDUIT BOX
TOP VIEW
30�$�
F F
F
PRESSURE
GAUGE
BOOSTER PUMP
TO BE MOUNTED IN
EXISTING PANEL
SEE NOTE 14 & 15
F
T7
F
EXISTING PANELF
F
F
F
T8
T1
F
T8
F
FF
DRIVER SUPPORT
DRAIN LINE
1957.34315.0TOTAL
74.84165.0SOLEPLATE
430.9950.0DRIVER
16.837.0COUPLING
1434.73163.0PUMP
KGLBS ITEM
WEIGHTS(APPROXIMATE)
A
B
C
D
A
B
C
D
GOULDS PUMPS
SHEET 2 OF 3
THIRD ANGLE
PROJECTION
FGAD315417
REVDRAWING
COPYRIGHT
APPROVED
CHECKED
S.W 03-02-16
DRAWN
HCL 03-02-16
DRAWING SCALE: NONE DIMENSIONS IN INCHES[MM]
PUMP OUTLINE DRAWING
MODEL VIT-FF
CUSTOMER: CDM CONSTRUCTORS INC.
GOULDS SERIAL NO.: 315417
PRODUCT NO: ----
CUSTOMER P.O. NO.: 110426.P.005
PUMP ITEM NO.: DOWN RIVER RAW WATER PUMPS DP-7 & DP-10
SERVICE: LOW PRESSURE SCREEN BACKWASH PUMPS
CUSTOMER DATA
C NO
ZZ
LE
Fz
Mz
S H A F T
FxFy My
Mx
L
COMMERCIAL (HI)
SINGLE NOZZLE LOADS
10. FOR PUMPS OVER 200HP[149 KW] THE PUMP ASSEMBLY HAS BEEN
DESIGNED SO THAT ITS NATURAL FREQUENCY RESPONSES AVOID
THE SPECIFIED MOTOR SPEED (OR SPEEDS) BY AN ADEQUATE
SAFTEY MARGIN.THE DESIGN ASSUMES A RIGID FOUNDATION
11. ONLY USE LIFTING LUGS ON DISCHARGE HEAD TO LIFT THE PUMP
12. FINITE ELEMENT ANALYSIS PERFORMED FOR THIS PUMP-MOTOR UNIT
PREDICTS THAT STRUCTURAL NATURAL FREQUENCY MODE EXISTS AT A
SPEED OF 1302 AND 1452 �#�3 RPM. THE PREDICTED MODE IS AN ABOVE
GROUND REED FREQUENCY RESPONSE. INITIAL OPERATION OF THE PUMP
AT THE PREDICTED SPEED SHOULD BE OBSERVED DURING INITIAL
OPERATION TO IDENTIFY DISCRETE SPEEDS AT WHICH EXCESS VIBRATION
COULD OCCUR AND MUST BE BLACKED OUT FROM OPERATION.
THE DESIGN ASSUMES A RIGID FOUNDATION.
13. ON OFF SEASON PERIOD, CUSTOMER SHOULD OPEN VALVE AND INJECT
CLEAN WATER 1.5 TO 2.5 GPMS FOR 3 MINUTES PRIOR TO
BUMP START AND CONTINUE FLUSH DURING THE BUMP START PROCESS.
14. BOOSTER PUMP PROVIDED BY ITT AND TO BE MOUNTED IN A EXISTING
PANEL NEXT TO THE VERTICAL PUMP.
15. BOOSTER PUMP MATERIALS: CASING- CAST IRON, IMPELLER- BRONZE.
16. VALVE TO BE OPEN 10%.
17. PRESSURE SENSOR SHOULD BE SET AT 12 PSI.
18. PERIODIC OBSERVATION AND CLEAN OUT OF FILTER IS REQUIRED.
19. RECOMMENDED BUMP TEST SPEED:
PUMP MINIMUM WET SPEED (HIGH WET WELL) IS 1424 RPM;
PUMP MAXIMUM WET SPEED (LOW WET WELL) IS 1780 RPM;
PUMP MAXIMUM DRY SPEED IS 180 RPM (SEE NOTE 13);
ITT GOULDS RECOMMENED TIME FOR OPERATION IS FOR A PERIOD
OF NO LONGER THAN 10 MINUTES.
V I T F F
CONNECTIONS TABLE
NO SIZE TYPE QTY PURPOSE STATUS FOR USE BY
T1 1/2" NPT 1 MOTOR SUPPORT DRAIN CONNECTED ITT
T2 1/2" NPT 1 TENSION PLATE (PLAN 32) INJECTION CONNECTED ITT
T3 8" 150# ASME RF SLIP ON FLANGE 1 PUMP DISCHARGE OPEN CUSTOMER
T4 1/2" NPT 1 PLAN 32 INJECTION CONNECTED ITT
T5 1/2" NPT ALL AUXILIARY CONNECTIONS PLUGGED CUSTOMER
T6 3/8" NPT 2 AUXILIARY CONNECTION PLUGGED CUSTOMER
T7 1/2" NPT 1 OFF SEASON LUBE INJECTION VALVE CLOSED CUSTOMER
T8 1/2" NPT 1 FILTER RETURN CONNECTED ITT
T9 1/2" NPT 1 TENSION PLATE LUBE INJECTION CONNECTED ITT
T10 1" NPT 1 BOOSTER PUMP INLET CONNECTED ITT
T11 1" NPT 1 BOOSTER PUMP OUTLET CONNECTED ITT
T12 1/2" NPT 1 FILTER HOUSING DRAIN NOTE 16 ITT
5.25 133,4[ ]
FOUNDATION LOADS
NORMAL OPERATIONAL FOUNDATION LOAD IN VERTICAL
DIRECTION �x� = 6004 LBS [26716 N]
FLANGE
SIZE
Fx Fy Fz Mx My Mz
LBS. [NEWTON] FT-LBS.[NEWTON-METER]
10"
[4492]
[4047]
[4999]
[2260]
[2703]
[1959]B1
F
F
F
-DETAIL A-
WATER FLUSH
TENSION PLATE
ADJUSTABLE
COUPLING
T6 T6
FROM BOOSTER PUMP
SEE GAD SHEET 3 OF 3
SEE NOTE 13
T7
T2
T9
F
F
F
F
F
F
F
F
1. ALL PUMPS EQUIPMENT SUPPLIED MUST BE INSTALLED,PIPED
AND OPERATED IN ACCORDANCE WITH API 686 AND THE INSTRUCTION
MANUAL PROVIDED WITH EQUIPMENT
2. TOLERANCE ON ALL PUMP DIMENSIONS IS �#�.12[3,0] OR �#�.12[3,0]
PER 5 FEET[1,5 M] WHICHEVER IS GREATER.TOLERANCE ON ALL
PIPING DIMENSIONS IS AS FOLLOWS: DISCHARGE FLANGE IS
�#�.12[3,0] , AUXILIARY CONNECTIONS ARE �#�1.0[25,4]
3. OPENING DIAMETER TO CLEAR PUMP,DRAIN AND COLUMN ASSEMBLY
IS 18.00 [457,2] MIN/19.00 [482,6] MAX
4. BEFORE INITIAL PUMP START UP, THE ROTOR MUST BE LIFTED
0.187[4,74].TO LIFT ROTOR USE ADJUSTING PLATE ON THE
ADJUSTABLE COUPLING.
5. M.A.W.P. DISCHARGE = 85 PSIG [5.86 BARG] @ 70�$�F [21.1�$�C]
6. MINIMUM HEIGHT REQUIRED TO REMOVE DRIVER IS 10.00 [254,0].
LIFT DRIVER SEPARATELY.DIMENSION DOES NOT INCLUDE THE
REQUIRED RIGGING DISTANCE BETWEEN THE TOP OF DRIVER
TO THE HOOK.
7. MINIMUM HEIGHT REQUIRED TO REMOVE ASSEMBLED PUMP
(LESS MOTOR) IS 409 [10388,4].DIMENSION DOES NOT INCLUDE
THE REQUIRED RIGGING DISTANCE BETWEEN THETOP OF
PUMP TO THE HOOK.
8. BOLT HOLES ON ALL FLANGES STRADDLE VERTICAL CENTERLINE
9. PRIOR TO PUMP INSTALLATION, SOLE PLATE SHALL BE
MOUNTED SEPARATELY ON FOUNDATION/STRUCTURE SUPPORTS.
SOLE PLATE SHALL BE LEVELED TO .002 INCHES PER FOOT
[,050 MM PER 304,8 MM] SECURED IN PLACE,AND EPOXY
GROUT SHALL BE FILLED BETWEEN FOUNDATION SUPPORTS
AND THE UNDERSIDE AND SIDES OF THE SOLE PLATE.AFTER
GROUT SETS,THE ANCHOR BOLTS SHALL BE FULLY TIGHTENED.
NOTES
A
B
C
D
A
B
C
D
GOULDS PUMPS
SHEET 3 OF 3
THIRD ANGLE
PROJECTION
FGAD315417
REVDRAWING
COPYRIGHT
APPROVED
CHECKED
S.W 03-02-16
DRAWN
HCL 03-02-16
DRAWING SCALE: NONE DIMENSIONS IN INCHES[MM]
PUMP OUTLINE DRAWING
MODEL VIT-FF
CUSTOMER: CDM CONSTRUCTORS INC.
GOULDS SERIAL NO.: 315417
PRODUCT NO: ----
CUSTOMER P.O. NO.: 110426.P.005
PUMP ITEM NO.: DOWN RIVER RAW WATER PUMPS UP-7 & UP-10
SERVICE: LOW PRESSURE SCREEN BACKWASH PUMPS
CUSTOMER DATA
2.17 55,0[ ]
3.58 91,0[ ]
1.91 48,5[ ]
3.82 97,0[ ]
THRU HOLES
4 PLACES
0.276 7,00[ ]
T4
DISCHARGE
NOZZLE
MODIFIED PLAN 32 AND
OFF SEASON LUBRICATION
SCHEMATIC
T6T6
1/2" X 1" NPT ADAPTER
BOOSTER PUMP FOOT PRINT
VIEW F-F
BOOSTER
PUMP INLET
CONNECTION
F
1" TUBING
T8
3/4" X 1/2"
REDUCING ADAPTER
HEAD MOUNTING
PLATE
T7
T11
F F
PRESSURE GAUGE
PRESSURE SWITCH
SEE NOTE 17
1/2" MALE X 1/4" FEMALE REDUCER
SIGHT FLOW
INDICATOR
T9T2
TEE 1/2"
BOOSTER PUMP
TENSION
PLATE
SPIN CLEAR FILTER
(SEE NOTE 18)
1-1/2" TO 1"
REDUCING COUPLING
1"NPT X 1" MALE
TUBE CONNECTOR
1" TUBING
EXISTING
CUSTOMER PANEL
SEE NOTE 13
T10
1" NPT X 1"
TUBE CONNECTOR
1/2" PIPE NIPPLE
1/2" X 1" NPT ADAPTER
3/4" FLEXIBLE HOSE
WITH NPT ENDS
1/2"NPT X 1/2"
MALE TUBE
CONNECTOR
T12 (NOTE 16)
1" NPT X 1"
TUBE CONNECTOR
| Sheet 1 |
| Views |
| new_view_2 |
| Zones |
| A1 |
| Sheet 2 |
| Sheet 3 |
| Zones |
| A1 |
File details come from the government source that posted it. Updated .