Appendix D GAD315412 for UPs 5 and 8 - mixing water pumps.pdf
PDF 463 KB Posted
- Solicitation number
- W912HN24Q5008
About this file
This document appears to be a pump outline drawing for model VIT-FF vertical turbine pumps, serial number 315412, which are mixing water pumps for the UP-5 and UP-8 stations. The drawing provides details on the pump dimensions, weights, nozzle loads, foundation loads, and various connections and fittings. It also includes notes on installation, operation, and maintenance requirements.
The related federal contract opportunity is for Dissolved Oxygen Vertical Turbine Pumps (VTP) Refurbishment Services, solicitation number W912HN24Q5008, issued by the Department of the Army Corps of Engineers Engineering District Savannah. The contractor shall provide all necessary services to perform VTP refurbishment as defined in the Performance Work Statement.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
B
C
D
A
B
C
D
GOULDS PUMPS
2.50 63,5[ ] 2.40
61,0[ ]
0.50 12,7[ ]
0.50 12,7[ ]
R1.00 25,4[ ]
1.00 25,4[ ] 3.50
88,9[ ]
REF.3.50
88,9[ ]
15.50 393,7[ ]
SEE
NOTE 3
10.75 273,1[ ]
GROUT
2.00 50,8[ ]
1.75 44,5[ ]
4.75
120,7[ ] RECOMMENDED
DRILLED HOLE
DIAMETER IS
0.88 MIN.
1.31 MAX.
SHEET 1 OF 3
THIRD ANGLE
PROJECTION
JGAD315412
REVDRAWING
COPYRIGHT
APPROVED
CHECKED
S.W 03-02-16
DRAWN
HCL 03-02-16
DRAWING SCALE: NONE DIMENSIONS IN INCHES[MM]
PUMP OUTLINE DRAWING
MODEL VIT-FF
CUSTOMER: CDM CONSTRUCTORS INC.
GOULDS SERIAL NO.: 315412
PRODUCT NO:----
CUSTOMER P.O. NO.: 110426.P.005
PUMP ITEM NO.: UP RIVER RAW WATER PUMPS UP-5 & UP-8
SERVICE: MIXING WATER PUMPS
CUSTOMER DATA
07-13-16DATE:S.WEBSTERSIGNATURE:
CERTIFIED FOR CONSTRUCTION ONLY WHEN SIGNED.
FOR PERFORMANCE INFORMATION REFER TO DATA SHEET
STAGES:1SIZE:8X12ELC
2PUMP QTY:MODEL: VIT-FF
FOR DRIVER INFORMATION SEE DRIVER PRINT
NIDECMFR.
DRIVER SPECIFICATIONS
TYPE: TENSION PLATEMFR: ITT
SHAFT SEAL
NOXYESGUARD PROVIDED:
ADJUSTABLETYPE:
ITTMFR:
COUPLING SPECIFICATIONS
LTR ZONE REVISION BY DATE
A1 - ADDED
S.W 07-12-16
A2 - REVISED
C1 - ADDED GREASE LINES
S.W 12-13-16C2 - ADDED
C3 - REVISED
D1 - REVISED S.W 03-09-17
E - ADDED ANCHOR BOLT DETAIL S.W 05-03-17
F1 - ADDED
S.W 05-22-17
F2 - REVISED
- ADDED
S.W 02-12-21
- REVISED
- REMOVED GREASE LINES
G4 - ADDED PLAN 31
V I T F F
LIFTING LUG
-DETAIL-
A1
A2
A2
D1
D1
T4
HEAD MOUNTING
FLANGE
T3
SEE NOTE 2 AND 5
PUMP ROTATION CCW
SEE SOLE PLATE
DETAIL
T5
A1
SACRIFICIAL
ANODES ON
BOWL ASSEMBLYD1
A2
MAIN PUMP ANCHOR BOLT
-DETAIL-
SUPPLIED BY CUSTOMER
SOLE PLATE
(2) WASHER
HEX NUT
E
RECOMMENDED SOLUTION
SIMPSON AT-XP + 7/8 316 SS
PER ASTM F593 OR EQUIVALENT
4 PLACES
F1
F2
SQ.
22.00 558,8[ ]
OPENING
19.00 482,6[ ]
4 PLACES
1.00 25,4[ ]
TYP.
11.00 279,4[ ]
TOTAL
PUMP LENGTH
458.69 11650,7[ ]
MIN.3.43
87,1[ ]
4.88 124,0[ ]
MIN.SUBMERGENCE
AT RATED FLOW
19.50 495,3[ ]
12.50 317,5[ ]
24.81 630,2[ ]
34.00 863,6[ ]
SEE
NOTE 6
SEE
NOTE 7
1.75 44,5[ ]
9.50 241,3[ ]
SQ.
25.00 635,0[ ]
TYP.
12.50 317,5[ ]
SOLE PLATE
-DETAIL-
PIT BOTTOM
DISCH.�q�
COUPLING GUARD
(2) LIFTING LUGS
SEE NOTE 11
T4
SEE DETAIL A
T1
CONDUIT BOX
TOP VIEW
30�$�
B1 - REVISED S.W 08-25-16
B2 - ADDED S.W 08-25-16
G1
G2
G3
H - REVISED SW 02-25-21
J - REVISED SW 05-24-21
B1
ADAPTER PLATE
B2
T8
PRESSURE
GAUGE
BOOSTER PUMP
TO BE MOUNTED IN
EXISTING PANEL
SEE NOTE 13 & 14
G1
G1
G1
G1
G2 G1
G2
G2
T7G1
H
J
J
T8
T1
J
EXISTING PANELJ
G1
J
J
DRIVER SUPPORT
DRAIN LINE
1659.23658.0TOTAL
74.8165.0SOLEPLATE
158.8350.0DRIVER
5.011.0COUPLING
1420.73132.0PUMP
KGLBS ITEM
WEIGHTS(APPROXIMATE)
A
B
C
D
A
B
C
D
GOULDS PUMPS
3.50 88,9[ ]
C NO
ZZ
LE
Fz
Mz
S H A F T
FxFy My
Mx
L
COMMERCIAL (HI)
SINGLE NOZZLE LOADS
SHEET 2 OF 3
THIRD ANGLE
PROJECTION
JGAD315412
REVDRAWING
COPYRIGHT
APPROVED
CHECKED
S.W 03-02-16
DRAWN
HCL 03-02-16
DRAWING SCALE: NONE DIMENSIONS IN INCHES[MM]
PUMP OUTLINE DRAWING
MODEL VIT-FF
CUSTOMER: CDM CONSTRUCTORS INC.
GOULDS SERIAL NO.: 315412
PRODUCT NO: ----
CUSTOMER P.O. NO.: 110426.P.005
PUMP ITEM NO.: UP RIVER RAW WATER PUMPS UP-5 & UP-8
SERVICE: MIXING WATER PUMPS
CUSTOMER DATA
CONNECTIONS TABLE
NO SIZE TYPE QTY PURPOSE STATUS FOR USE BY
T1 1/2" NPT 1 MOTOR SUPPORT DRAIN CONNECTED ITT
T2 1/2" NPT 1 TENSION PLATE (PLAN 32) INJECTION CONNECTED ITT
T3 8" 150# ASME RF SLIP ON FLANGE 1 PUMP DISCHARGE OPEN CUSTOMER
T4 1/2" NPT 1 PLAN 32 INJECTION CONNECTED ITT
T5 1/2" NPT ALL AUXILIARY CONNECTIONS PLUGGED CUSTOMER
T6 3/8" NPT 2 AUXILIARY CONNECTION PLUGGED CUSTOMER
T7 1/2" NPT 1 CUSTOMER
T8 1/2" NPT 1 ITT
T9 1/2" NPT 1 TENSION PLATE LUBE INJECTION CONNECTED ITT
T10 1" NPT 1 CONNECTED ITT
T11 1" NPT 1 CONNECTED ITT
V I T F F
A1
A2
A2
T6 T6 A1
C3
-DETAIL A-
WATER FLUSH
TENSION PLATE
ADJUSTABLE
COUPLING
10. FOR PUMPS OVER 200HP[149 KW] THE PUMP ASSEMBLY HAS BEEN
DESIGNED SO THAT ITS NATURAL FREQUENCY RESPONSES AVOID
THE SPECIFIED MOTOR SPEED (OR SPEEDS) BY AN ADEQUATE
SAFTEY MARGIN.THE DESIGN ASSUMES A RIGID FOUNDATION
11. ONLY USE LIFTING LUGS ON DISCHARGE HEAD TO LIFT THE PUMP
12. ON OFF SEASON PERIOD, CUSTOMER SHOULD OPEN VALVE AND INJECT
CLEAN WATER 1.5 TO 2.5 GPMS FOR 3 MINUTES PRIOR TO
BUMP START AND CONTINUE FLUSH DURING THE BUMP START PROCESS.
13. BOOSTER PUMP PROVIDED BY ITT AND TO BE MOUNTED IN A EXISTING
PANEL NEXT TO THE VERTICAL PUMP.
14. BOOSTER PUMP MATERIALS: CASING- CAST IRON, IMPELLER- BRONZE.
15. VALVE TO BE OPEN 10%.
16. SET PRESSURE SENSOR AT 5 PSI.
17. PERIODIC OBSERVATION AND CLEAN OUT OF FILTER IS REQUIRED.
18. RECOMMENDED BUMP TEST SPEED:
PUMP MINIMUM WET SPEED (HIGH WET WELL) IS 1424 RPM;
PUMP MAXIMUM WET SPEED (LOW WET WELL) IS 1780 RPM;
PUMP MAXIMUM DRY SPEED IS 180 RPM (SEE NOTE 12);
ITT GOULDS RECOMMENED TIME FOR OPERATION IS FOR A PERIOD
OF NO LONGER THAN 10 MINUTES.
FOUNDATION LOADS
NORMAL OPERATIONAL FOUNDATION LOAD IN VERTICAL
DIRECTION �x� = 5286 LBS [23522 N]
FLANGE
SIZE
Fx Fy Fz Mx My Mz
LBS. [NEWTON] FT-LBS.[NEWTON-METER]
8"
[3594]
[3238]
[3999]
[1687]
[2032]
[1459]
OFF SEASON LUBE INJECTION VALVE CLOSED
FILTER RETURN CONNECTED
BOOSTER PUMP INLET
BOOSTER PUMP OUTLET
T12 1/2" NPT 1 FILTER HOUSING DRAIN NOTE 15 ITT
FROM BOOSTER PUMP
SEE GAD SHEET 3 OF 3
SEE NOTE 12
T7 G1
G1
G2
G1
G1
G1
G2
G2
T2
G1
G1
T9
G1
G1
H
J
J
J
J
J
J
J
J
1. ALL PUMPS EQUIPMENT SUPPLIED MUST BE INSTALLED,PIPED
AND OPERATED IN ACCORDANCE WITH API 686 AND THE INSTRUCTION
MANUAL PROVIDED WITH EQUIPMENT
2. TOLERANCE ON ALL PUMP DIMENSIONS IS �#�.12[3,0] OR �#�.12[3,0]
PER 5 FEET[1,5 M] WHICHEVER IS GREATER.TOLERANCE ON ALL
PIPING DIMENSIONS IS AS FOLLOWS: DISCHARGE FLANGE IS
�#�.12[3,0] , AUXILIARY CONNECTIONS ARE �#�1.0[25,4]
3. OPENING DIAMETER TO CLEAR PUMP,DRAIN AND COLUMN ASSEMBLY
IS 18.0 [457,2] MIN/19.0 [482,6] MAX
4. BEFORE INITIAL PUMP START UP, THE ROTOR MUST BE LIFTED
0.187[4.74].TO LIFT ROTOR USE ADJUSTING PLATE ON THE
ADJUSTABLE COUPLING.
5. M.A.W.P. DISCHARGE = 40 PSIG [2.75 BARG] @ 70�$�F [21.1�$�C]
6. MINIMUM HEIGHT REQUIRED TO REMOVE DRIVER IS 10 [254].
LIFT DRIVER SEPARATELY.DIMENSION DOES NOT INCLUDE THE
REQUIRED RIGGING DISTANCE BETWEEN THE TOP OF DRIVER
TO THE HOOK.
7. MINIMUM HEIGHT REQUIRED TO REMOVE ASSEMBLED PUMP
(LESS MOTOR) IS 506.0 [12852,4].DIMENSION DOES NOT INCLUDE
THE REQUIRED RIGGING DISTANCE BETWEEN THETOP OF
PUMP TO THE HOOK.
8. BOLT HOLES ON ALL FLANGES STRADDLE VERTICAL CENTERLINE
9. PRIOR TO PUMP INSTALLATION, SOLE PLATE SHALL BE
MOUNTED SEPARATELY ON FOUNDATION/STRUCTURE SUPPORTS.
SOLE PLATE SHALL BE LEVELED TO .002 INCHES PER FOOT
[,050 MM PER 304,8 MM] SECURED IN PLACE,AND EPOXY
GROUT SHALL BE FILLED BETWEEN FOUNDATION SUPPORTS
AND THE UNDERSIDE AND SIDES OF THE SOLE PLATE.AFTER
GROUT SETS,THE ANCHOR BOLTS SHALL BE FULLY TIGHTENED.
NOTES
A
B
C
D
A
B
C
D
GOULDS PUMPS
SHEET 3 OF 3
THIRD ANGLE
PROJECTION
JGAD315412
REVDRAWING
COPYRIGHT
APPROVED
CHECKED
S.W 03-02-16
DRAWN
HCL 03-02-16
DRAWING SCALE: NONE DIMENSIONS IN INCHES[MM]
PUMP OUTLINE DRAWING
MODEL VIT-FF
CUSTOMER: CDM CONSTRUCTORS INC.
GOULDS SERIAL NO.: 315412
PRODUCT NO: ----
CUSTOMER P.O. NO.: 110426.P.005
PUMP ITEM NO.: UP RIVER RAW WATER PUMPS UP-5 & UP-8
SERVICE: MIXING WATER PUMPS
CUSTOMER DATA
2.17 55,0[ ]
3.58 91,0[ ]
1.91 48,5[ ]
3.82 97,0[ ]
THRU HOLES
4 PLACES
0.276 7,00[ ]
T4
DISCHARGE
NOZZLE
MODIFIED PLAN 32 AND
OFF SEASON LUBRICATION
SCHEMATIC
G4
T6T6
1/2" X 1" NPT ADAPTER
BOOSTER PUMP FOOT PRINT
VIEW F-F
BOOSTER
PUMP INLET
CONNECTION
J
1" TUBING
T8
3/4" X 1/2"
REDUCING ADAPTER
HEAD MOUNTING
PLATE
T7
T11
F F
PRESSURE GAUGE
PRESSURE SWITCH
SEE NOTE 16
1/2" MALE X 1/4" FEMALE REDUCER
SIGHT FLOW
INDICATOR
T9T2
TEE 1/2"
BOOSTER PUMP
TENSION
PLATE
SPIN CLEAR FILTER
(SEE NOTE 17)
1-1/2" TO 1"
REDUCING COUPLING
1"NPT X 1" MALE
TUBE CONNECTOR
1" TUBING
EXISTING
CUSTOMER PANEL
SEE NOTE 13
T10
1" NPT X 1"
TUBE CONNECTOR
1/2" PIPE NIPPLE
1/2" X 1" NPT ADAPTER
3/4" FLEXIBLE HOSE
WITH NPT ENDS
1/2"NPT X 1/2"
MALE TUBE
CONNECTOR
T12 (NOTE 15)
1" NPT X 1"
TUBE CONNECTOR
| Sheet 1 |
| Views |
| new_view_2 |
| Zones |
| A1 |
| Sheet 2 |
| Sheet 3 |
| Zones |
| A1 |