This document appears to be an appendix that provides technical specifications and details for a high pressure pump model VIT-FF, including dimensional drawings, performance curves, operating parameters, and connection details. The pump is intended for use in a high pressure screen backwash application as part of a raw water pumping system. Key details include the pump model, size, impeller diameter, discharge pressure rating, foundation loads, and required installation and operating procedures. This appendix does not appear to be directly related to the referenced federal contract opportunity for Dissolved Oxygen Vertical Turbine Pumps refurbishment services. Rather, it provides technical information about a specific pump that may be used in a similar application.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
B
C
D
A
B
C
D
GOULDS PUMPS
3.75 95,3[ ]
2.40 61,0[ ]
0.75 19,1[ ]
0.75 19,1[ ]
R1.50 38,1[ ]
1.50 38,1[ ]
4.00 101,6[ ]
REF.
6.00 152,4[ ]
17.50 444,5[ ]
10.75 273,1[ ]
GROUT
2.00 50,8[ ]
1.75 44,5[ ]
4.75
120,65[ ] RECOMMENDED
DRILLED HOLE
DIAMETER IS
0.88 MIN.
1.31 MAX.
SHEET 1 OF 3
THIRD ANGLE
PROJECTION
FGAD315411
REVDRAWING
COPYRIGHT
APPROVED
CHECKED
S.W 03-02-16
DRAWN
HCL 03-02-16
DRAWING SCALE: NONE DIMENSIONS IN INCHES[MM]
PUMP OUTLINE DRAWING
MODEL VIT-FF
CUSTOMER: CDM CONSTRUCTORS INC.
GOULDS SERIAL NO.: 315411
PRODUCT NO: ----
CUSTOMER P.O. NO.: 110426.P.005
PUMP ITEM NO.: UP RIVER RAW WATER PUMPS UP-4 & UP-7
SERVICE: HIGH PRESSURE SCREEN BACKWASH PUMPS
CUSTOMER DATA
07-12-16DATE:S.WEBSTERSIGNATURE:
CERTIFIED FOR CONSTRUCTION ONLY WHEN SIGNED.
FOR PERFORMANCE INFORMATION REFER TO DATA SHEET
STAGES:4SIZE:8X12JHC
2PUMP QTY:MODEL: VIT-FF
FOR DRIVER INFORMATION SEE DRIVER PRINT
NIDECMFR.
DRIVER SPECIFICATIONS
TYPE: TENSION PLATEMFR: ITT
SHAFT SEAL
NOXYESGUARD PROVIDED:
ADJUSTABLETYPE:
ITTMFR:
COUPLING SPECIFICATIONS
LTR ZONE REVISION BY DATE
A1 - ADDED
S.W 07-12-16
A2 - REVISED
B1 - ADDED GREASE LINES
S.W 12-10-16B2 - REVISED
B3 - ADDED
D - ADDED ANCHOR BOLT DETAIL S.W 05-03-17
E1 - ADDED
S.W 05-22-17
E2 - REVISED
V I T F
FLIFTING LUG
-DETAIL-
F
A1
A2
T4
HEAD MOUNTING
FLANGE
T3
SEE NOTE 2 AND 5
PUMP ROTATION CCW
SEE SOLE PLATE
DETAIL
T5
TOP VIEW
T8
ANCHOR BOLT
-DETAIL-
SUPPLIED BY CUSTOMER
SOLE PLATE
(2) WASHER
HEX NUT
D
RECOMMENDED SOLUTION
SIMPSON AT-XP + 7/8 316 SS
PER ASTM F593 OR EQUIVALENT
4 PLACES
E1
E2
F
SQ.
22.00 558,8[ ]
OPENING
19.00 482,6[ ]
4 PLACES
1.00 25,4[ ]
TYP.
11.00 279,4[ ]
TOTAL
PUMP LENGTH
462.50 11747,5[ ]
MIN.2.00
50,8[ ]
5.00
127,0[ ] MIN.SUBMERGENCE
AT RATED FLOW
19.20 487,7[ ]
SEE
NOTE 3
11.25 285,8[ ]
46.00 1168,4[ ]
39.00 990,6[ ]
SEE
NOTE 6
SEE
NOTE 7
SOLE PLATE
1.75 44,5[ ]
12.00 304,8[ ]
SQ.
25.00 635,0[ ]
TYP.
12.50 317,5[ ]
SOLE PLATE
-DETAIL-
PIT BOTTOM
DISCH.�q�
COUPLING GUARDS
(2) LIFTING LUGS
SEE NOTE 11
T4
SEE DETAIL A
T1
CONDUIT BOX
40�$�
C1 - ADDED S.W 03-09-17
F REVISED SW 05-24-21
A2
A2
A2
A2
PRESSURE
GAUGE
T8
T1
SACRIFICIAL
ANODES ON
BOWL ASSEMBLY
F
F
F
F
T7
DRIVER SUPPORT
DRAIN LINE
2399.15289.0TOTAL
74.8165.0SOLEPLATE
680.41500.0DRIVER
16.837.0COUPLING
1627.03587.0PUMP
KGLBS ITEM
WEIGHTS(APPROXIMATE)
A
B
C
D
A
B
C
D
GOULDS PUMPS
SHEET 2 OF 3
THIRD ANGLE
PROJECTION
FGAD315411
REVDRAWING
COPYRIGHT
APPROVED
CHECKED
S.W 03-02-16
DRAWN
HCL 03-02-16
DRAWING SCALE: NONE DIMENSIONS IN INCHES[MM]
PUMP OUTLINE DRAWING
MODEL VIT-FF
CUSTOMER: CDM CONSTRUCTORS INC.
GOULDS SERIAL NO.: 315411
PRODUCT NO: ----
CUSTOMER P.O. NO.: 110426.P.005
PUMP ITEM NO.: UP RIVER RAW WATER PUMPS UP-4 & UP-7
SERVICE: HIGH PRESSURE SCREEN BACKWASH PUMPS
CUSTOMER DATA
C NO
ZZ
LE
Fz
Mz
S H A F T
FxFy My
Mx
L
COMMERCIAL (HI)
SINGLE NOZZLE LOADS
V I T F F
B3 11. ONLY USE LIFTING LUGS ON DISCHARGE HEAD TO LIFT THE PUMP
12. FINITE ELEMENT ANALYSIS PERFORMED FOR THIS PUMP-MOTOR UNIT
PREDICTS THAT STRUCTURAL NATURAL FREQUENCY MODE EXISTS AT A
SPEED OF 1274 �#�3 RPM. THE PREDICTED MODE IS AN ABOVE
GROUND REED FREQUENCY RESPONSE. INITIAL OPERATION OF THE PUMP
AT THE PREDICTED SPEED SHOULD BE OBSERVED DURING INITIAL
OPERATION TO IDENTIFY DISCRETE SPEEDS AT WHICH EXCESS
VIBRATION COULD OCCUR AND MUST BE BLACKED OUT FROM OPERATION.
THE DESIGN ASSUMES A RIGID FOUNDATION.
13. ON OFF SEASON PERIOD, CUSTOMER SHOULD OPEN VALVE AND INJECT
CLEAN WATER 1.5 TO 2.5 GPMS FOR 3 MINUTES PRIOR TO
BUMP START AND CONTINUE FLUSH DURING THE BUMP START PROCESS.
14. VALVE TO BE OPEN 10%.
15. SET PRESSURE AT 35 PSI.
16. PERIODIC OBSERVATION AND CLEAN OUT OF FILTER IS REQUIRED.
17. RECOMMENDED BUMP TEST SPEED:
PUMP MINIMUM WET SPEED (HIGH WET WELL) IS 1424 RPM;
PUMP MAXIMUM WET SPEED (LOW WET WELL) IS 1780 RPM;
PUMP MAXIMUM DRY SPEED IS ZERO RPM. MULTI-STAGE UNITS
ARE TO BE ROTATED BY HAND ONLY(SEE NOTE 13).
CONNECTIONS TABLE
NO SIZE TYPE QTY PURPOSE STATUS FOR USE BY
T1 1/2" NPT 1 MOTOR SUPPORT DRAIN CONNECTED ITT
T2 1/2" NPT 1 TENSION PLATE (PLAN 32) INJECTION CONNECTED ITT
T3 8" 150# ASME RF SLIP ON FLANGE 1 PUMP DISCHARGE OPEN CUSTOMER
T4 1/2" NPT 1 PLAN 32 INJECTION CONNECTED ITT
T5 1/2" NPT ALL AUXILIARY CONNECTIONS PLUGGED CUSTOMER
T6 3/8" NPT 2 AUXILIARY CONNECTION PLUGGED CUSTOMER
T7 1/2" NPT 1 OFF SEASON LUBE INJECTION VALVE CLOSED CUSTOMER
T8 1/2" NPT 1 FILTER RETURN CONNECTED ITT
T9 1/2" NPT 1 TENSION PLATE LUBE INJECTION CONNECTED ITT
T10 1/2" NPT 1 FILTER HOUSING DRAIN NOTE 14 ITT
5.25 133,4[ ]
FOUNDATION LOADS
NORMAL OPERATIONAL FOUNDATION LOAD IN VERTICAL
DIRECTION �x� = 7855 LBS [34953 N]
FLANGE
SIZE
Fx Fy Fz Mx My Mz
LBS. [NEWTON] FT-LBS.[NEWTON-METER]
8"
[3594]
[3238]
[3998]
[1686]
[2032]
[1458]
-DETAIL A-
WATER FLUSH
TENSION PLATE
ADJUSTABLE
COUPLING
T6 T6
FROM SPIN FILTER
SEE GAD SHEET 3 OF 3
T7
T2
T9
F
F
SEE
NOTE 13
F
F
F
F
F
F
F
1. ALL PUMPS EQUIPMENT SUPPLIED MUST BE INSTALLED,PIPED
AND OPERATED IN ACCORDANCE WITH API 686 AND THE INSTRUCTION
MANUAL PROVIDED WITH EQUIPMENT
2. TOLERANCE ON ALL PUMP DIMENSIONS IS �#�.12[3,0] OR �#�.12[3,0]
PER 5 FEET[1,5 M] WHICHEVER IS GREATER.TOLERANCE ON ALL
PIPING DIMENSIONS IS AS FOLLOWS: DISCHARGE FLANGE IS
�#�.12[3,0] , AUXILIARY CONNECTIONS ARE �#�1.0[25,4]
3. OPENING DIAMETER TO CLEAR PUMP,DRAIN AND COLUMN ASSEMBLY
IS 18.00 [457,2] MIN/19.00 [482,6] MAX
4. BEFORE INITIAL PUMP START UP, THE ROTOR MUST BE LIFTED
0.187[4,74].TO LIFT ROTOR USE ADJUSTING PLATE ON THE
ADJUSTABLE COUPLING.
5. M.A.W.P. DISCHARGE = 133 PSIG [9.17 BARG] @ 70�$�F [21.1�$�C]
6. MINIMUM HEIGHT REQUIRED TO REMOVE DRIVER IS 10.00 [254,0].
LIFT DRIVER SEPARATELY.DIMENSION DOES NOT INCLUDE THE
REQUIRED RIGGING DISTANCE BETWEEN THE TOP OF DRIVER
TO THE HOOK.
7. MINIMUM HEIGHT REQUIRED TO REMOVE ASSEMBLED PUMP
(LESS MOTOR) IS 513.00 [13030,2].DIMENSION DOES NOT INCLUDE
THE REQUIRED RIGGING DISTANCE BETWEEN THETOP OF
PUMP TO THE HOOK.
8. BOLT HOLES ON ALL FLANGES STRADDLE VERTICAL CENTERLINE
9. PRIOR TO PUMP INSTALLATION, SOLE PLATE SHALL BE
MOUNTED SEPARATELY ON FOUNDATION/STRUCTURE SUPPORTS.
SOLE PLATE SHALL BE LEVELED TO .002 INCHES PER FOOT
[,050 MM PER 304,8 MM] SECURED IN PLACE,AND EPOXY GROUT
SHALL BE FILLED BETWEEN FOUNDATION SUPPORTS AND THE
UNDERSIDE AND SIDES OF THE SOLE PLATE.AFTER GROUT SETS,
THE ANCHOR BOLTS SHALL BE FULLY TIGHTENED.
10. FOR PUMPS OVER 200HP[149 KW] THE PUMP ASSEMBLY HAS BEEN
DESIGNED SO THAT ITS NATURAL FREQUENCY RESPONSES AVOID
THE SPECIFIED MOTOR SPEED (OR SPEEDS) BY AN ADEQUATE
SAFTEY MARGIN.THE DESIGN ASSUMES A RIGID FOUNDATION.
NOTES
A
B
C
D
A
B
C
D
GOULDS PUMPS
SHEET 3 OF 3
THIRD ANGLE
PROJECTION
FGAD315411
REVDRAWING
COPYRIGHT
APPROVED
CHECKED
S.W 03-02-16
DRAWN
HCL 03-02-16
DRAWING SCALE: NONE DIMENSIONS IN INCHES[MM]
PUMP OUTLINE DRAWING
MODEL VIT-FF
CUSTOMER: CDM CONSTRUCTORS INC.
GOULDS SERIAL NO.: 315411
PRODUCT NO: ----
CUSTOMER P.O. NO.: 110426.P.005
PUMP ITEM NO.: UP RIVER RAW WATER PUMPS UP-4 & UP-7
SERVICE: HIGH PRESSURE SCREEN BACKWASH PUMPS
CUSTOMER DATA
T4
DISCHARGE
NOZZLE
MODIFIED PLAN 32 AND
OFF SEASON LUBRICATION
SCHEMATIC
T6T6
1/2" X 1" NPT ADAPTER
F
1" TUBING
T8
3/4" X 1/2"
REDUCING ADAPTER
HEAD MOUNTING
PLATE
T7
PRESSURE GAUGE
PRESSURE SWITCH
(SEE NOTE 15)
1/2" MALE X 1/4" FEMALE REDUCER
SIGHT FLOW
INDICATOR
T9T2
TEE 1/2"
TENSION
PLATE
SPIN CLEAR FILTER
(SEE NOTE 16)
1-1/2" TO 1"
REDUCING COUPLING
1" TUBING
1" NPT X 1"
TUBE CONNECTOR
1/2" PIPE NIPPLE
1/2" X 1" NPT ADAPTER
3/4" FLEXIBLE HOSE
WITH NPT ENDS
1/2"NPT X 1/2"
MALE TUBE
CONNECTOR
T10 (NOTE 14)
1" NPT X 1"
TUBE CONNECTOR
| Sheet 1 |
| Views |
| new_view_2 |
| Zones |
| A1 |
| Sheet 2 |
| Sheet 3 |
| Zones |
| A1 |
File details come from the government source that posted it. Updated .