Appendix 3A-Addendum to Physical Security Requirements.pdf

PDF 59 KB Posted

Attached to
Contractor-Hosted Fully Integrated Records Facility (FIRF) IDIQ
Solicitation number
75F40126R00009
Issued by

About this file

This is an addendum to an ID/IQ (Indefinite Delivery/Indefinite Quantity) contract appendix that modifies physical security requirements and specifications for FDA facilities.

The addendum clarifies that four items from Section I (FDA Sole Occupant) are not applicable to this contract: garage area/inside parking, secured area for government vehicles, perimeter parking, and guard service. Additionally, the document revises the Intrusion Detection/Access Control System requirements for Section II (FDA Occupant in Multi-Tenant Building). The revised specifications require card readers on all perimeter door entrances, intrusion alarms with door contacts and window sensors to protect all FDA space, optional video intercoms with remote release stations, and integration with the FDA Physical Security Access Control System. These requirements establish the minimum security infrastructure that contractors must implement or maintain for FDA facilities operating in multi-tenant buildings.

View the file

Other files

File Type Posted
2026-10-07 Amendment 0003_RFP 75F40126R00009 FIRF IDIQ.pdf PDF
2026-10-07 Amendment 0003_Attachment E-Sample Task Order Statement of Work.pdf PDF
2026-10-07 Attachment L-Questions and Answers.xlsx XLSX spreadsheet
2026-09-30 Amendment 0002_RFP 75F40126R00009 FIRF IDIQ.pdf PDF
2026-09-08 Amendment 0001_RFP 75F40126R00009 FIRF IDIQ.pdf PDF
RFP 75F40126R00009 FIRF IDIQ.pdf PDF
Appendix 2-Basic RP LAN Room Layout.pdf PDF
Attachment C-IDIQ Pricing Worksheet.xlsx XLSX spreadsheet
Attachment H-Commitment to Protect Non-Public Information (NPI) Employee Agreement Form FDA 3398.pdf PDF
Attachment K-Sample Task Order Pricing Worksheet.xlsx XLSX spreadsheet
Appendix 1-OIMT_IT-Spaces-Cabling-Guidelines.pdf PDF
Appendix 4-CDRH Work Functions.xlsx XLSX spreadsheet
Attachment G-Past Performance Questionnaire.docx DOCX document
Attachment I-RFP Question Submittal Form.xlsx XLSX spreadsheet
Attachment J-Contractor Personnel Security Clearance Standards and Residency Requirements (OCT 2017).pdf PDF
Appendix 5-FDA-CDRH Document Control Ceneter (DCC) Tracking System Requirements.pdf PDF
Attachment F-Labor Category Descriptions.pdf PDF
Appendix 3-FDA Physical Security Requirements.pdf PDF
Attachment B-Wage Determinations (2015-4269 and 2015-4281).pdf PDF
Attachment D-Disclosure of Lobbying Activities SF-LLL.pdf PDF
Attachment E-Sample Task Order Statement of Work.pdf PDF
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Addendum to ID/IQ Appendix#2: Physical Security Requirements/Specifications for FDA Facilities

The following items contained in Section I. FDA Sole Occupant are not applicable:

1) Garage Area (Inside Parking);

2) Secured Area for Government Vehicles;

3) Perimeter Parking; and

4) Guard Service.

Intrusion Detection/Access Control System contained in Section II. FDA Occupant in Multi-Tenant Building is revised to state:

INTRUSION DETECTION/ACCESS CONTROL SYSTEM

1) Card readers will be utilized on all perimeter door entrances.

2) Intrusion alarms, door contacts, and window sensors will be utilized to protect all FDA space.

3) Video intercoms with remote release stations may be utilized.

4) Connected to FDA Physical Security Access Control System.