Addendum No. 2 R-7265 QM Village Shops.pdf
PDF 9 MB Posted
- Attached to
- R-7265 Queen Mary Village Demolition
- Solicitation number
- PW-25-540
- Issued by
- California
About this file
Queen Mary Village Demolition - Addendum No. 2
This is an Addendum No. 2 to the Notice to Proposers for Specifications No. R-7265, issued by the City of Long Beach Department of Public Works on February 18, 2025. The addendum modifies the original plans and specifications for the Queen Mary Village Demolition project located at 1119 Queens Highway, Long Beach, California 90802. The project involves comprehensive demolition of existing structures and site preparation. Bidders must acknowledge receipt of this addendum by signing and submitting it with their proposals; failure to do so may result in disqualification. The addendum includes updated grading quantities, revisions to demolition and protection notes across multiple plan sheets, and new construction details for cast-in-place stairs and pipe railing installations. The contractor must mobilize no later than April 1, 2025. Responses to nine bidder inquiries (RFI) are provided to address questions regarding the engineer's estimate, start date, fill material specifications, fencing requirements, utility terminations, retaining wall requirements, survey monument preservation, and staircase protection status.
The Engineer's Estimate for the project is $1,250,000. Key plan revisions include updated soils and aggregate base grading quantities on Sheet C100, modifications to demolition and protection notes on Sheet C201 regarding a planter wall, stairs, fencing, and planting, and new construction details on Sheet C300 for pipe railing anchoring and cast-in-place stairs. Fill material under paving shall be compacted to 90 percent of maximum dry density using existing on-site soils. The site must remain secure throughout construction with temporary fencing per Specification Division H 7-10.6.1. Domestic and fire backflows will be terminated and demolished by the Long Beach Water Department. Retaining walls designated to remain will do so regardless of backfill placement. Survey monument preservation is a city requirement, with contractors responsible for identifying and documenting any monuments disturbed during construction. The existing staircase previously marked for protection will be demolished and replaced with a new cast-in-place staircase with new handrails as detailed in the revised architectural and civil drawings.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
City of Long Beach
Department of Public Works Project Management Bureau 411 W Ocean Blvd. 5th floor, Long Beach, California 90802 p 562.570.6383
February 18, 2025
NOTICE TO PROPOSERS
ADDENDUM NO. 2 PLAN AND SPECIFICATION CHANGES:
SPECIFICATIONS NO. R-7265
QUEEN MARY VILLAGE DEMOLITION
This addendum changes and supersedes the language in the original plans and specifications.
Please acknowledge receipt of this addendum by signing and submitting with your proposals. Any bidder who fails to submit this addendum may be disqualified.
Please note the following clarifications, additions, or changes:
PLANS
Plans for the QUEEN MARY VILLAGE DEMOLITION (Drawing Number B-4853) are replaced in its entirety with the attached drawings dated 2/17/2025. All revisions are clouded and noted, and descriptions of changes are summarized below:
A summary of plan revisions and edits are provided below. Bidders shall submit pricing per the clarifications and responses below:
Sheet C100 – Grading Information (4) “SOILS GRADING QUANTITIES (CU.YD.)” EXPORT quantities have been updated. “AGGREGATE BASE GRADING QUANTITITES (CU.YD.)” table has been added.
Sheet C201 – Three Callouts:
o Retaining wall adjacent to planter is changed from Demolition Note (D2) “EXISTING
PLANTER WALL/CURB TO BE DEMO’ED” to Protection Note (3) “EXISTING WALL TO
REMAIN”
o Stairs adjacent to building foundation is changed from Protection Note (13) “EXISTING STAIRS TO REMAIN” to Demolition Note (D12) “EXISTING STAIRS AND
ASSOCIATED FOOTINGS TO BE DEMO’ED”
o Add Demolition Note (D23) “EXISTING FENCE TO BE DEMO’ED” and Demolition Note
(D24) “EXISTING PLANTING TO BE DEMO’ED”
Sheet C300 – One Callout:
o Add Construction Note 2 “PIPE RAILING TO BE ANCHORED TO EXISTING
RETAINING WALL” to new retaining wall.
Addendum No. 2 – Specification No. R-7265 o Add Construction Note 6 “CONCRETE, CAST-IN-PLACE STAIRS ON GRADE PER DETAIL C/C300”. New staircase.
o Revised linework showing new staircase.
Sheet C301 – Two Callouts:
o Updated quantities for “AGGREGATE BASE GRADING SUMMARY” and “SOILS
GRADING SUMMARY”
o Revised cut fill lines showing new staircase.
Sheet C400 – One Callout:
o Revised linework showing new staircase Sheet A101 – Three Callouts:
o Add Demo Plan Keynotes o Existing planter/curb adjacent to staircase to remain o Add Demo Plan Keynote 26 to stairs adjacent to building foundation o Add Demo Plan Keynote 46 “FENCING TO BE DEMOED” and Demo Plan Keynote 47
“PLANTING TO BE DEMOED
Sheet A102 – Two Callouts:
o Existing planter/curb to remain.
o Add Floorplan Keynote 19 “(N) STAIR, CAST IN PLACE. NEW HANDRAILS BOTH
SIDES, SEE CIVIL & 5/A501”
Sheet A501 – Updated Details:
o Detail 1 “STAIR SECTION, EXISTING” modified to show existing conditions.
o Detail 3 “NEW WALL ELEVATION” modified to show new stairs.
o Detail 5 “STAIR PLAN, NEW” added
RESPONSES TO REQUESTS FOR INFORMATION (RFI)
Question #1: What is the Engineer’s Estimate?
Response #1: The Engineer’s Estimate for this project is $1,250,000.
Question #2: Is there an estimated start date?
Response #2: The contractor will be required to mobilize no later than April 1, 2025.
Question #3: Can the RFI deadline be extended?
Response #3: The RFI deadline will not be extended.
Question #4: Where the lower landing and stairs are, what kind of pack fill material will be used?
Response #4: Per Specification Section 31 23 23 Fill, fill under paving shall be compacted to 90% of maximum dry density. Utilize existing on-site soils for fill. Refer to Plans Sheet C301 for Cut/Fill areas.
Question #5: Will fencing be needed for the entire perimeter?
Response #5: Yes, the site must be secure for the duration of construction. See Specification
Division H 7-10.6.1 Temporary Security/Construction Fence.
Question #6: Can we shut the fire riser at the valve along the property perimeter itself?
Response#6: Domestic and Fire backflows are planned to be terminated and demolished by the
Long Beach Water Department.
Question #7: If we backfill some of those areas, will the retaining walls still need to remain?
Response #7: Refer to Plans Sheet C301 for Cut/Fill areas. Refer to Plans Sheet C201 and
A101 for retaining walls to remain regardless of backfill.
Question #8: Reference Plan Sheet G001 - On the attached plan sheet there is a survey monument note, highlighted in green, which states the following: The contractor shall be responsible for the preservation and perpetuation of all existing monuments which control subdivisions, tracts, boundaries or right of way, or which provide survey control, including benchmarks, which will be disturbed by the contractors activities. Is this an actual requirement for the project?
Response #8: Yes, this is a city requirement. See Division H - General Requirements. The
Contractor is required to identify if any monuments are on site.
Question #9: Reference Plan Sheet A101 - On the attached plan sheet we have highlighted a section of stairs that are to be protected in place. The stairs are right up against a building structure that is to be demolished as well as a retaining wall. When demolishing the building structure and retaining wall these stairs may get damaged. Please advise if it is the intent for these stairs to be protected in place.
Response #9: This staircase will be demolished and replaced with a new staircase. See revised
Plan Sheets C300, C301, C400, A102, A501 which show the location and details of the new staircase.
CONTACT: Before the Bid opening, prospective Bidders shall direct any communications regarding this Work to:
City of Long Beach, Department of Public Works Project Management Bureau 5th Floor, City Hall 411 W. Ocean Boulevard Long Beach, CA 90802 Attention: Michael Lau / TidelandsCIP E-mail: Michael.Lau@psomas.com / TidelandsCIP@longbeach.gov
Communications may be written or oral, but the City is not bound by any oral interpretation of the Contract Documents made by any City employee, nor does the City guarantee the accurate transcription of oral questions.
PREPARED BY: Michael Lau, PSOMAS
ACKNOWLEDGED BY: __________________________________________________
Company Name
Print Name Title
Signature Date
RA-DA
ARCHITECT:
7523 NORTON AVENUE
WEST HOLLYWOOD
CA 90046
T. 323.851.4040
VICINITY MAP
S U
R V
E Y
C O
N T
R O
L
IN
S
P E
C T
IO
N
SHEET
NOTE:
OF
MUNIS Project #
F
IE
L D
B O
O K
S C
A L E
P A
G E
G R
A P
H
IC
P R
O J E
C T
O F
F
IC
E R
D E
S
IG
N C
H E
C K
B Y
D R
A F
T
IN
G C
H E
C K
B Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
R E
V
IS
IO
N
S
A S
-B U
IL
T
:D A
T E
N o
S
H E
E T
S A
P P
R O
V A
L
R E
F
C
IT
Y G
R
ID
D W
G
N O
Phase# ____ / Rebid:____
P R
O J E
C T
M A
N A
G E
R
DRAWING REF.
W
O C
E A
N B
L V
D
L O
N G
B E
A C
H
C A
C
IT
Y
O F
L O
N G
B E
A C
H
D
E P
A R
T M
E N
T O
F P
U B
L
IC
W O
R K
S
CLB BENCHMARK NO. 920
ELEV. 13.478FT
MSL DATUM, NGVD 1929
1985 ADJUSTMENT
BRASS DISC FLUSH WITH PVMT STAMPED ``CLB BM 920 R.E. 3111, 1969",
22.0 E / CURB 5.5' N / CURB ELEV
PROJECT
SITE
SCALE: NONE
CITY OF
LONG BEACH
SAN DIEGO
WILLOW ST.
SPRING ST.
L O
N G
B E
A
B L V
D
OCEAN
BROADWAY
ANAHEIM ST.
PACIFIC COAST HWY.
L O
N G
E
A
F
Y
S A
N T
A
M A
G N
O
IA
V
E
T E
R M
IN
A
L
ISLAND
F W
Y
223RD ST.
SEPULVEDA
DEL AMO BLVD.
ARTESIA FWY.
ARTESIA BLVD.
VICTORIA ST.
CANDLEWOOD ST.
P A
R A
M O
U
V
D
A T
L A
N
IC
E
STEARNS ST.
LO
S
C O
YO
TES
L A
K E
W O
O
V
D
C L A
R
E
P A
R
E
B E
L L F
L O
W
V
D
A T
L A
N
E
O R
A N
E
C H
E R
Y
E
P A
C
IF
E
L O
A
V
D
M A
R
IN
U
T H
IN
J
E
ANAHEIM ST.
BROADWAY
R E
D O
N
E
T E
M P
E
BLVD.
7TH ST.
A L A
M
IT
E
H W
Y .X
IM
E
E
OCEAN
BLVD.
2ND ST.LIVINGSTON DR.
PACIFIC
C
O
AST
7TH ST.
S T
U D
E B
A K
E R
ATHERTON ST.
DEL AMO BLVD.CITY OF LAKEWOOD
CARSON ST.
CITY OF
SIGNAL HILL
WARDLOW RD.
FWY.
O
R A
N G
E
C H
E R
R Y
W O
O D
R U
E
C L A
E
WARDLOW RD.
SPRING ST.
WILLOW ST.
S A N D
IEG
O
L A
K E
W O
O D
L.A. CO.
D
IA
G O
N A L
WESTMINSTER
AVE.
SAN DIEGO FWY.
S
B
R
IE
L
FW
Y
N O
R W
A
V
D
F W
Y
S A
N G
A B
R
IE
Y
R D
ARTESIA BLVD.
SOUTH ST.
MARKET ST.
A V
E
A V
E
ARTESIA FWY.
B L
V D
L
G
E L
IV
E R
L O
S C
E R
R
IT
O S
C H
A N
N E
L
S
B R
IE
IV
E R
P
IE
E
OCEAN BLVD.
SEASIDE BLVD.
PIER F A
VE.
PIER D
A
VE
N A
V Y
W A
Y
A V
E
P
IC
O
PIER B ST.
A V
E
P A
C
IF
E
SAN ANTONIO
DR
AVE.
47 710
SURVEY MONUMENT NOTE
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION AND PERPETUATION OF
ALL EXISTING MONUMENTS WHICH CONTROL SUBDIVISIONS, TRACTS, BOUNDARIES OR RIGHT-
OF-WAY, OR WHICH PROVIDE SURVEY CONTROL, INCLUDING BENCHMARKS, WHICH WILL BE
DISTURBED BY THE CONTRACTOR'S ACTIVITIES.
AFTER RECEIVING THE NOTICE-TO-PROCEED, THE CONTRACTOR, USING THE SERVICES OF A
SURVEYOR LICENSED IN CALIFORNIA, SHALL SUBMIT TO THE CITY SURVEYOR, JON HORNECKER, PLS, 10TH FLOOR CITY HALL, PRELIMINARY CORNER RECORD FOR THOSE MONUMENTS THAT
WERE FOUND IN THE AREA OF CONSTRUCTION.
THE CONTRACTOR'S SURVEYOR SHALL SET NEW TIES FOR ANY MONUMENTS WHOSE TIES ARE
DISTURBED, AND PREPARE PRELIMINARY CORNER RECORDS FOR THE NEW TIES.
AFTER CONSTRUCTION THE CONTRACTOR'S SURVEYOR SHALL SUBMIT TO THE CITY THE
PRELIMINARY CORNER RECORDS FOR ANY MONUMENTS REPLACE OR CONSTRUCTED, OR
WHOSE TIES ARE RESET THE CONTRACTOR'S SURVEYOR SHALL FILE CORNER RECORDS FOR
THOSE MONUMENTS IN THE OFFICE OF THE COUNTY SURVEYOR AND SHALL PROVIDE THE CITY
WITH A COPY OF ALL CORNER RECORDS FIELD. (CA BUSINESS & PROFESSIONS CODE SECTION
8771, 8772 & 8773)
BENCHMARK PERPETUATION NOTE
PRIOR TO REMOVALS, THE CONTRACTOR SHALL REQUEST THE ALSO CITY OF LONG BACH
SURVEYOR, JON HORNECKER, (562) 570-6992, TO TRANSFER THE ELEVATION FOR ANY BENCH
MARKS TO BE RESET, TO TEMPORARY BENCH MARKS; AND PROVIDE A BRASS DISC FOR THE
CITY SURVEYOR TO STAMP. WHEN THE DISCS ARE STAMPED AND RETURNED TO THE
CONTRACTOR, THE CONTRACTOR SHALL CONSTRUCT THE BENCH MARKS AT LOCATIONS
MARKED OUT BY THE CITY SURVEYOR
CITY SURVEYOR'S STATEMENT
I HAVE REVIEWED THE PLAN(S) FOR COMPLIANCE WITH BUSINESS AND PROFESSIONS CODE §§
8771, 8772 AND 8773.
JON HORNECKER, PLS-7212
CITY SURVEYOR-CITY OF LONG BEACH
C O
V E
R S
H E
E T
G001
Q U
E E
N M
A R
Y V
IL
L
A G
E D
E M
O L
IT
IO
N
240322
Q u e e n s
H w y, L o n g B e a ch
C A
B-4853
PROJECT DESCRIPTIONPROJECT DESCRIPTIONPROJECT DESCRIPTIONPROJECT DESCRIPTION
ZONE: 3
DISTRICT: PD-21 (4)
YEAR BUILT: N/A
CONSTRUCTION TYPE: N/A
OCCUPANCY TYPE: N/A
BUILDING AREA SQFT OVERALL: 11,430 SQ. FT
SQ. FT OF PROJECT AREA: NO CHANGE
RELEVANT CODESRELEVANT CODESRELEVANT CODESRELEVANT CODES
CALIFORNIA BUILDING CODE 2022
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA MECHANICAL CODE
2022 CALIFORNIA PLUMBING CODE
2022 CALIFORNIA FIRE CODE
2022 CALIFORNIA GREEN BUILDING STANDARD CODE
2022 CALIFORNIA ENERGY CODE (TITLE 24) AND TITLE 18 OF THE LONG BEACH
MUNICIPAL CODE
PROJECT TEAMPROJECT TEAMPROJECT TEAMPROJECT TEAM
CONSTRUCTION MANAGER
MICHAEL LAU
PSOMASPSOMASPSOMASPSOMAS
michael.lau@psomas.com C: 626.840.4674
ARCHITECT
RARARARA----DADADADA
RANIA ALOMAR
RANIA@RA-DA-.COM
T: 323.851.4040
CIVIL& STRUCTURAL ENGINEER:
TEGTEGTEGTEG
MELISSA TAGUCHI
melissa@teglosangeles.com O: 310.613.9980
PROJECT SCOPE:PROJECT SCOPE:PROJECT SCOPE:PROJECT SCOPE:
DEMOLISH EXISTING VILLAGE BUILDINGS DOWN TO GRADE. FINAL SITE
WILL HAVE 2 LEVELS WITH SMALL RETAINING WALL AND GUARDRAIL
FINAL SITE TO BE REPAVED WITH ASPHALT
GENERAL NOTES:GENERAL NOTES:GENERAL NOTES:GENERAL NOTES:
1. GC TO THOROUGHLY STUDY HAZARDOUS MATERIALS REPORT PRIOR
TO ANY WORK & IMPLEMENT ALL APPROPRIATE PROCEDURES AS
INDICATED IN REPORT.
HAZARDOUS MATERIALS REPORT REFERS TO:
"HAZARDOUS BUILDING MATERIAL SURVEY" BY NINYO & MOORE,
DATED MARCH 7TH 2024
OWNER:
CITY OF LONG BEACHCITY OF LONG BEACHCITY OF LONG BEACHCITY OF LONG BEACH
CHARLENE ANGSUCO
PUBLIC WORKS | PROJECT MANAGEMENT OFFICER
411 W OCEAN BLVD, 5TH FLOOR | LONG BEACH, CA 90802
Charlene.Angsuco@longbeach.gov T: 562.570.5733
QUEEN MARY VILLAGE DEMOLITION
1119 QUEENS HWY, LONG BEACH, CA 90802
VICINITY MAP
PROJECT LOCATION
1119 QUEENS HWY,
LONG BEACH, CA 90802
SHEET LIST
Sheet Number Sheet Name
Issued 03.26.2024
Issued 07.08.2024
BID SET
10.27.2024 ASI-001
BID SET
02.17.2025
G001 COVER SHEET O X X X
G002 GENERAL NOTES O X
G003 GREEN FORMS O X
C100 Title Sheet O X X X X
C200 Existing Site Plan O X X X
C201 Demolition/Utility Plan O X X X X
C300 Grading Plan O X X X X
C301 Cut/Fill Diagram Plan O X X X X
C400 Erosion Control Plan O X
A001 General Architectural Information
O X X X
A100 Existing Site Plan O X X X
A101 Demolition Plan O X X X X
A102 New Site Plan O X X X X
A500 Details O X X X
A501 Details O X X
A502 Details - Curb Ramp O X
A503 Notes - Curb Ramp O X
X = REISSUE SHEET
O = NEW SHEET
BID SET 02.17.2025
DRAWING REF.
E
F
C
IT
Y G
R
ID
SHEET
OF
F
IE
L D
B O
O K
S C
A L E
P A
G E
G R
A P
H
IC
A S
-B U
IL
T
D A
T E
N o
S
H E
E T
D E
S C
R
IP
T
IO
N
R E
V
IS
IO
N
S D
E S
IG
N
E D
B Y
D R
A W
N B
Y
D R
A F
T
IN
G C
H E
C K
B Y
D E
S
IG
N C
H E
C K
B Y
A P
P R
O V
A L
NOTE:
MUNIS Project #
Phase# ____ / Rebid:____
RA-DA
7523 NORTON AVE.
WEST HOLLYWOOD CA 90046
T. 323-851-4040
RANIA@RA-DA.COM
WWW.RA-DA.COM
DRAWING NUMBER
2/17/2025 5:22:21 PM
G E
N E
R A
L N
O T
E S
G002
Q U
E E
N M
A R
Y V
IL
L
A G
E D
E M
O L
IT
IO
N
240322
Q u e e n s
H w y, L o n g B e a ch
C A
B-4853
Issue Date
B
ID
S E
T
.1
.2
GENERAL CONTRACTOR DEMOLITION NOTES
1. REVIEW CONSTRUCTION DOCUMENTS AND FIELD CONDITIONS PRIOR TO
COMMENCING WITH DEMOLITION AND IMMEDIATELY REPORT
DISCREPANCIES TO ARCHITECT FOR DIRECTION ON HOW TO PROCEED
2. CONTACT OWNER REPRESENTATIVE IF HAZARDOUS MATERIALS ARE
FOUND, THEY SHALL BE REMOVED PER APPROPRIATE LOCAL, STATE AND
FEDERAL STANDARDS.
3. DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN, BUT IS TO
INCLUDE WHAT IS NECESSARY TO COMPLETE THE WORK IN ACCORDANCE
WITH FULL SCOPE OF THE CONTRACT DOCUMENTS
4. DEMOLITION DRAWINGS PREPARED BY ARCHITECT ARE FOR A GENERAL
DESCRIPTION OF EXISTING BUILDING COMPONENTS, ASSEMBLIES AND
MATERIALS TO BE REMOVED. VERIFY ALL EXISTING CONDITION AND
QUANTITIES
5. PROTECT EXISTING ADJACENT AREAS NOT IN THE SCOPE OF THIS
CONTRACT PRIOR TO AND DURING THE DEMOLITION PHASE. PROTECTION TO
BE MAINTAINED UNTIL 100% COMPLETION OF THE DEMOLITION. ANY
DAMAGE TO ADJACENT NEW AND EXISTING STRUCTURES OR EQUIPMENT
SHALL BE CONTRACTOR'S RESPONSIBILITY AND SHALL BE IMMEDIATELY
REPAIRED OR REPLACED TO THE SATISFACTION OF THE CLIENT AT THE
EXPENSE OF THE GENERAL CONTRACTOR
6. FURNISH ALL LABOR, MATERIALS & EQUIPMENT AS REQUIRED TO
COMPLETE DEMOLITION AND REMOVAL OF ALL ITEMS AS INDICATED.
7. COORDINATE WITH CLIENT REPRESENTATIVE ALL ASPECTS OF THE
DEMOLITION AND CONSTRUCTION WORK. EXECUTE ALL WORK WITHIN THE
REGULATIONS OF PROPERTY CLIENT FOR DEMOLITION & REMOVAL OF
DEBRIS, INCLUDING AFTER HOUR WORK, AS REQUIRED
8. COORDINATE WITH CLIENT REPRESENTATIVE REGARDING SCHEDULING OF
CUTTING/CORING OF SLAB, SHOOTING OF TRACK, PLUMBING AND OTHER
NOISE-RELATED CONSTRUCTION ACTIVITIES.
9. REMOVE AND DISPOSE OF ALL DEMOLISHED MATERIALS IN A MANNER
COMPLIANT TO FEDERAL, STATE AND LOCAL MUNICIPAL REQUIREMENTS
AND GUIDELINES
10. COORDINATE THE STORAGE OF SALVAGED MATERIALS: (i.e: DOORS, FRAMES, HARDWARE, HVAC EQUIPMENT,ETC) WITH THE CLIENT
REPRESENTATIVE
11. FURNISH THE CLIENT REPRESENTATIVE WITH A COMPLETE INVENTORY
LIST OF ALL ITEMS THAT CAN BE REUSED AND/OR STORED IN BUILDING
ATTIC STOCK, AND OBTAIN DIRECTIVE REGARDING THEIR DISPOSITION
12. ALL DEMOLISHED MATERIAL OTHER THAN ITEMS TO BE SALVAGED,
REUSED OR RETURNED TO THE CLIENT SHALL BECOME CONTRACTORS
PROPERTY UNO, AND SHALL BE REMOVED FROM THE PREMISES. CLEAN UP
AND DISPOSE OF DEBRIS PROMPTLY AND CONTINUOUSLY AS THE WORK
PROGRESSES. SECURE AND PAY FOR REQUIRED HAULING PERMITS, PAY
DUMPING FEES AND CHARGES.
13. REMOVE FROM PREMISES ALL CONDUITS, BOXES, PLATES, BRIDGES, OR
ANY OTHER TELEPHONE AND/OR ELECTRICAL WIRING & EQUIPMENT LEFT
AFTER WALL DEMOLITION.
14. REMOVE ALL DATA/TELE CABLING
15. UPON COMPLETION OF THE DEMOLITION WORK, ENSURE THAT ALL
AREAS ARE LEFT IN A CLEAN AND BROOM SWEPT CONDITION
16. PROVIDE NEW TEMPORARY CHAIN LINK FENCE AND PEDESTRIAN
CANOPY, AS REQUIRED, WITH GRAPHIC-PRINTED MESH COVERING. GRAPHICS
TO BE APPROVED BY CITY PRIOR TO FABRICATION.
17. COMBUSTIBLE DEBRIS SHALL NOT BE ACCUMULATED WITHIN BUILDINGS.
COMBUSTIBLE DEBRIS, RUBBISH AND WASTE MATERIAL SHALL BE REMOVED
FROM BUILDINGS AT THE END OF EACH SHIFT OF WORK. (CFC 3304.2)
18. MATERIALS SUSCEPTIBLE TO SPONTANEOUS IGNITION, SUCH AS OILY
RAGS, SHALL BE STORED IN A LISTED DISPOSAL CONTAINER. (CFC 3304.2.4)
DEMOLITION NOTES
GENERAL CONTRACTOR GENERAL NOTES
1. VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO
COMMENCEMENT OF WORK. THIS INCLUDES: UTILITIES, ALL OTHER WORKS AND
FACILITIES THAT AFFECT THIS PROJECT. NO ALLOWANCE SHALL BE MADE FOR
ANY EXTRA EXPENSE OR EXTENSION OF TIME DUE TO CONTRACTORS FAILURE OR
NEGLECT OF COMPLETE EXAMINATION OF THE JOB SITE
2. ANY DISCREPANCIES, CONFLICTS OR OMISSIONS ETC., SHALL BE NOTIFIED TO
ARCHITECT PRIOR TO PROCEEDING WITH THE WORK
3. SUBMIT TO THE CLIENT REPRESENTATIVE A DETAILED DEMOLITION SCHEDULE
INDICATING PHASING OF WORK FROM START TO FINISH OF PROJECT, INCLUDING
A CRITICAL PATH SCHEDULE
4. ENTERING INTO AN AGREEMENT WITH THE CLIENT INDICATES THAT THE
CONTRACTOR(S) HAVE VISITED THE JOB SITE, FAMILIARIZED THEMSELVES WITH
EXISTING CONDITIONS AND REVIEWED THE SAME WITH THE REQUIREMENTS OF
THE CONTRACT DOCUMENTS
5. PROVIDE NECESSARY PERMITS REQUIRED BY FEDERAL, STATE AND LOCAL
MUNICIPAL AGENCIES HAVING JURISDICTIONAL AUTHORITY. THE CONTRACTOR
SHALL OBTAIN AND PAY FOR THE BUILDING PERMIT. EACH SUBCONTRACTOR
SHALL OBTAIN AND PAY FOR SUCH PERMITS, LICENSES AND INSPECTIONS
NECESSARY FOR PERFORMANCES OF HIS WORK AND INCLUDE THOSE IN THE
COST OF THE WORK TO THE CLIENT
6. PROVIDE THE MINIMUM INSURANCE REQUIREMENTS PER CITY REQUIREMENTS
7. MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION DOCUMENTS ON
THE JOB SITE DURING ALL PHASES OF CONSTRUCTION FOR USE BY ALL TRADES
AND PROVIDE ALL SUB CONTRACTORS WITH CURRENT CONSTRUCTION
DOCUMENTS.
8. ANY AND ALL REVISIONS SHALL BE WRITTEN CHANGE ORDER FORM, REVIEWED
BY ARCHITECT AND APPROVED AND AUTHORIZED BY CLIENT BEFORE BEGINNING
WORK.
9. THE INTENT OF THE DRAWING IS TO SHOW EXISTING BUILDING CONDITIONS
WITH INFORMATION DEVELOPED FROM VISUAL OBSERVATION. UNIDENTIFIED
ITEMS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CLIENT
REPRESENTATIVE AND ARCHITECT PRIOR TO REMOVAL
10. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN, UNLESS OTHERWISE
NOTED. LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS. SPECS
GOVERN OVER DRAWINGS.
11. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE
CONSIDERED CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS QUESTIONS
REGARDING THEIR EXACT MEANING, CLARIFICATION SHALL BE REQUESTED FROM
ARCHITECT.
12. ANY REVISION OR ADDITIONAL WORK REQUIRED BY THE CLIENT, FIELD
CONDITIONS OR LOCAL GOVERNING AUTHORITIES SHALL BE BROUGHT TO THE
ATTENTION OF THE CLIENT OR ARCHITECT BEFORE PROCEEDING REGARDLESS OF
COST, TIME OR MATERIAL INCREASE
13. PROTECT SIDEWALK, PERIMETER FENCES AND ADJACENT NEIGHBORS
PROPERTY FROM DAMAGE WHICH MAY OCCUR FROM DEMOLITION,DUST,WATER,
ETC. AND PROVIDE AND MAINTAIN TEMPORARY BARRICADES, CLOSURE
WALLS,ETC. AS REQUIRED TO PROTECT THE PUBLIC DURING CONSTRUCTION.
DAMAGE TO EXISTING MATERIAL,FINISHES, STRUCTURE AND EQUIPMENT SHALL
BE REPAIRED OR REPLACED TO
THE SATISFACTION OF THE CLIENT'S REPRESENTATIVE AT THE EXPENSE OF THE
CONTRACTOR
14. DEACTIVATE ALL UTILITY LINES IN CONTRACT AREA BEFORE STARTING WORK.
15. REMOVE ALL RUBBISH AND WASTE MATERIALS ON A REGULAR BASIS, OF ALL
SUB-CONTRACTORS AND TRADES. EXERCISE STRICT CONTROL OVER JOB
CLEANING THROUGHOUT CONSTRUCTION, INCLUDING FINAL CLEAN UP UPON
COMPLETION OF WORK.
STORM WATER PREVENTION NOTES
1. FUELS, OIL, SOLVENTS & OTHER TOXIC MATERIALS SHALL BE STORED IN
ACCORDANCE WITH THEIR LISTING & ARE NOT TO CONTAMINATE THE SOIL &
SURFACE WATERS. ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED
FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY & DISPOSED OF IN
A
PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE DRAINAGE SYSTEM, NOR
BE ALLOWED TO SETTLE OR INFILTRATE INTO SOIL.
2. EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY
OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE
WASTE ON SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTES.
3. TRASH & CONSTRUCTION SOLID WASTES SHALL BE DEPOSITED INTO A COVERED
RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER & DISPERSAL BY WIND.
4. SEDIMENTS & OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY
VEHICULAR TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE
STABILIZED SO AS TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC
WAY. ACCIDENTAL DEPOSITS SHALL BE SWEPT UP IMMEDIATELY & MAY NOT BE
WASHED DOWN BY RAIN OR OTHER MEANS.
5. ANY SLOPES WITH DISTURBED SOILS OR REMOVED VEGETATION SHALL BE
STABILIZED TO INHIBIT EROSION BY WIND & WATER.
6. STORM WATER POLLUTION PREVENTION DEVICES &/OR PRACTICES SHALL BE
MODIFIED AS NEEDED AS THE PROJECT PROGRESS TO ENSURE EFFECTIVENESS.
GENERAL NOTES STORM WATER PREVENTION NOTES
GENERAL CONTRACTOR CONSTRUCTION WASTE NOTES
1. CONSTRUCTION WASTE MATERIALS ARE TO BE RECYCLED, CONTRACTOR TO
FOLLOW THE REQUIREMENTS OF THE LOCAL JURISDICTION. CONTRACTOR TO
SUBMIT WASTE MANAGEMENT FORMS AND DEPOSIT PRIOR TO PULLING PERMITS.
CONSTRUCTION WASTE NOTES
E
F
C
IT
Y G
R
ID
SHEET
OF
F
IE
L D
B O
O K
S C
A L E
P A
G E
G R
A P
H
IC
A S
-B U
IL
T
D A
T E
N o
S
H E
E T
D E
S C
R
IP
T
IO
N
R E
V
IS
IO
N
S D
E S
IG
N
E D
B Y
D R
A W
N B
Y
D R
A F
T
IN
G C
H E
C K
B Y
D E
S
IG
N C
H E
C K
B Y
A P
P R
O V
A L
NOTE:
MUNIS Project #
Phase# ____ / Rebid:____
RA-DA
7523 NORTON AVE.
WEST HOLLYWOOD CA 90046
T. 323-851-4040
RANIA@RA-DA.COM
WWW.RA-DA.COM
DRAWING NUMBER
2/17/2025 5:22:21 PM
G R
E E
N F
O R
M S
G003
Q U
E E
N M
A R
Y V
IL
L
A G
E D
E M
O L
IT
IO
N
240322
Q u e e n s
H w y, L o n g B e a ch
C A
B-4853
Issue Date
B
ID
S E
T
.1
.2
Ti tl e Sh ee t
Q U
EE
N
M A
R Y
VI
LL
A G
E D
EM
O
LI
TI
O N
Q ue en s
H w y, L on g
B ea ch , C
A
GRADING GENERAL NOTES
1. ALL GRADING AND CONSTRUCTION SHALL CONFORM TO THE CITY OF LONG BEACH BUILDING
CODES AND THE STATE MODEL WATER EFFICIENCY LANDSCAPE ORDINANCE UNLESS
SPECIFICALLY NOTED ON THESE PLANS.
2. ANY MODIFICATIONS OF OR CHANGES TO APPROVED GRADING PLANS MUST BE APPROVED BY THE
BUILDING OFFICIAL.
3. ALL GRADING AND CONSTRUCTION ACTIVITIES SHALL COMPLY WITH CITY OF MUNICIPAL CODE
THAT REGULATES THE HOURS OF OPERATION OF THE USE OF CONSTRUCTION AND GRADING
EQUIPMENT.
4. CALIFORNIA PUBLIC RESOURCES CODE (SECTION 5097.98) AND HEALTH AND SAFETY CODE
(SECTION 7050.5) ADDRESS THE DISCOVERY AND DISPOSITION OF HUMAN REMAINS. IN THE EVENT
OF DISCOVERY OR RECOGNITION OF ANY HUMAN REMAINS IN ANY LOCATION OTHER THAN A
DEDICATED CEMETERY, THE LAW REQUIRES THAT GRADING IMMEDIATELY STOPS AND NO FURTHER EXCAVATION OR DISTURBANCE OF THE SITE, OR ANY NEARBY AREA WHERE HUMAN REMAINS MAY
BE LOCATED, OCCUR UNTIL THE FOLLOWING MEASURES HAVE BEEN TAKEN:
4.A. THE COUNTY CORONER HAS BEEN INFORMED AND HAS DETERMINED THAT NO
INVESTIGATION OF THE CAUSE OF DEATH IS REQUIRED, AND
4.B. IF THE REMAINS ARE OF NATIVE AMERICAN ORIGIN, THE DESCENDANTS FROM THE
DECEASED NATIVE AMERICANS HAVE MADE A RECOMMENDATION FOR THE MEANS OF
TREATING OR DISPOSING, WITH APPROPRIATE DIGNITY, OF THE HUMAN REMAINS AND ANY
ASSOCIATED GRAVE GOODS.
5. THE LOCATION AND PROTECTION OF ALL UTILITIES IS THE RESPONSIBILITY OF THE PERMITTEE.
6. ALL EXPORT OF MATERIAL FROM THE SITE MUST GO TO A PERMITTED SITE APPROVED BY THE
BUILDING OFFICIAL OR A LEGAL DUMPSITE. RECEIPTS FOR THE ACCEPTANCE OF EXCESS
MATERIAL BY A DUMPSITE MAY BE REQUIRED.
7. A COPY OF THE GRADING PERMIT AND APPROVED GRADING PLANS MUST IN THE POSSESSION OF A
RESPONSIBLE PERSON AND AVAILABLE AT THE SITE AT ALL TIMES.
8. NO GRADING OR CONSTRUCTION SHALL OCCUR WITHIN THE PROTECTED ZONE OF ANY OAK TREE.
THE PROTECTED ZONE SHALL MEAN THAT AREA WITHIN THE DRIP LINE OF AN OAK TREE
EXTENDING THERE FROM A POINT AT LEAST FIVE FEET OUTSIDE THE DRIP LINE, OR 15 FEET FROM
THE TRUNK(S) OF A TREE, WHICHEVER IS GREATER.
9. A PREVENTIVE PROGRAM TO PROTECT THE SLOPES FROM POTENTIAL DAMAGE FROM BURROWING
RODENTS IS REQUIRED. OWNER IS TO INSPECT SLOPES PERIODICALLY FOR EVIDENCE OF
BURROWING RODENTS AND AT FIRST EVIDENCE OF THEIR EXISTENCE SHALL EMPLOY AN
EXTERMINATOR FOR THEIR REMOVAL.
10. IF GRADING AUTHORIZED BY THIS PLAN IS TO EXTEND THROUGH THE RAINY SEASON, NOVEMBER 1 THROUGH APRIL 15 OF THE FOLLOWING YEAR, SEPARATE UPDATED PLANS FOR EROSION CONTROL
MUST BE SUBMITTED PRIOR TO OCTOBER.
DRAINAGE NOTES
1. ROOF DRAINAGE MUST BE DIVERTED FROM GRADED SLOPES.
2. PROVISIONS SHALL BE MADE FOR CONTRIBUTORY DRAINAGE AT ALL TIMES.
3. IF CONSTRUCTION AND GRADING WITHIN A STORM DRAIN EASEMENT ARE TO BE DONE, ALL WORK IS TO BE DONE PER PRIVATE DRAIN PD NO.___________________ OR MISCELLANEOUS TRANSFER
DRAIN MTD NO.___________________.
4. ALL STORM DRAIN WORK IS TO BE DONE UNDER CONTINUOUS INSPECTION BY THE FIELD
ENGINEER.
GEOTECHNICAL NOTES
THE GEOTECHNICAL REPORT AND ADDENDUMS ARE CONSIDERED PART OF THE PLANS AND SHOULD
BE KEPT AT THE JOBSITE AT ALL TIMES.
GEOTECHNICAL ENGINEER
CONTACT INFORMATION ABOVE
LIST OF REPORTS & ADDENEDUMS
FILL NOTES
1. ALL FILL SHALL BE COMPACTED TO THE FOLLOWING MINIMUM RELATIVE COMPACTION CRITERIA:
1 90 PERCENT OF MAXIMUM DRY DENSITY
THE RELATIVE COMPACTION SHALL BE DETERMINED BY A.S.T.M. SOIL COMPACTION TEST D1557-91 WHERE APPLICABLE: WHERE NOT APPLICABLE, A TEST ACCEPTABLE TO THE BUILDING OFFICIAL
SHALL BE USED.
2. FIELD DENSITY SHALL BE DETERMINED BY A METHOD ACCEPTABLE TO THE BUILDING OFFICIAL.
HOWEVER, NOT LESS THAN 10% OF THE REQUIRED DENSITY TEST, UNIFORMLY DISTRIBUTED, AND
SHALL BE OBTAINED BY THE SAND CONE METHOD.
3. SUFFICIENT TESTS OF THE FILL SOILS SHALL BE MADE TO DETERMINE THE RELATIVE COMPACTION
OF THE FILL IN ACCORDANCE WITH THE FOLLOWING MINIMUM GUIDELINES:
3.A. ONE TEST FOR EACH TWO-FOOT VERTICAL LIFT.
3.B. ONE TEST FOR EACH 1,000 CUBIC YARDS OF MATERIAL PLACED.
3.C. ONE TEST AT THE LOCATION OF THE FINAL FILL SLOPE FOR EACH BUILDING SITE (LOT) IN
EACH FOUR-FOOT VERTICAL LIFT OR PORTION THEREOF.
3.D. ONE TEST IN THE VICINITY OF EACH BUILDING PAD FOR EACH FOUR-FOOT VERTICAL LIFT OR
PORTION THEREOF.
4. SUFFICIENT TESTS OF FILL SOILS SHALL BE MADE TO VERIFY THAT THE SOIL PROPERTIES COMPLY
WITH THE DESIGN REQUIREMENTS, AS DETERMINED BY THE SOIL ENGINEER INCLUDING SOIL
TYPES, SHEAR STRENGTH PARAMETERS AND CORRESPONDING UNIT WEIGHTS IN ACCORDANCE
WITH THE FOLLOWING GUIDELINES:
4.A. PRIOR AND SUBSEQUENT TO PLACEMENT OF THE FILL, SHEAR TESTS SHALL BE TAKEN ON
EACH TYPE OF SOIL OR SOIL MIXTURE TO BE USED FOR ALL FILL SLOPES STEEPER THAN
THREE (3) HORIZONTAL TO ONE VERTICAL.
4.B. SHEAR TEST RESULTS FOR THE PROPOSED FILL MATERIAL MUST MEET OR EXCEED THE
DESIGN VALUES USED IN THE GEOTECHNICAL REPORT TO DETERMINE SLOPE STABILITY
REQUIREMENTS. OTHERWISE THE SLOPE MUST BE REEVALUATED USING THE ACTUAL
SHEAR TEST VALUE OF THE FILL MATERIAL THAT IS IN PLACE.
4.C. FILL SOILS SHALL BE FREE OF DELETERIOUS MATERIALS.
5. FILL SHALL NOT BE PLANTED UNTIL STRIPPING OF VEGETATION, REMOVAL OF UNSUITABLE SOILS, AND INSTALLATION OF SUBDRAIN (IF ANY) HAVE BEEN INSPECTED AND APPROVED BY THE SOIL ENGINEER. THE BUILDING OFFICIAL MAY REQUIRE A "STANDARD TEST METHOD FOR MOISTURE, ASH, ORGANIC MATTER, PEAT OR OTHER ORGANIC SOILS" ASTM D-2974-87 ON ANY SUSPECT
MATERIAL. DETRIMENTAL AMOUNTS OF ORGANIC MATERIAL SHALL NOT BE PERMITTED IN FILLS.
SOIL CONTAINING SMALL AMOUNTS OF ROOTS MAY BE ALLOWED PROVIDED THAT THE ROOTS ARE IN A QUANTITY AND DISTRIBUTED IN A MANNER THAT WILL NOT BE DETRIMENTAL TO THE FUTURE
USE OF THE SITE AND THE SOILS ENGINEER APPROVES THE USE OF SUCH MATERIAL.
6. ROCK OR SIMILAR MATERIAL GREATER THAN 6 INCHES IN DIAMETER SHALL NOT BE PLACED IN
THE FILL UNLESS RECOMMENDATIONS FOR SUCH PLACEMENTS HAVE BEEN SUBMITTED BY THE
SOIL ENGINEER AND APPROVED IN ADVANCE BY THE BUILDING OFFICIAL. LOCATION, EXTENT, AND
ELEVATION OR ROCK DISPOSAL AREAS MUST BE SHOWN ON AN "AS BUILT" GRADING PLAN.
7. CONTINUOUS INSPECTION BY THE SOIL ENGINEER, OR A RESPONSIBLE REPRESENTATIVE, SHALL BE PROVIDED DURING ALL FILL PLACEMENT AND COMPACTION OPERATIONS WHERE FILLS HAVE A
DEPTH GREATER THAN 30 FEET OR SLOPE SURFACE STEEPER THAN 2:1.
8. FILL SLOPES IN EXCESS OF 2:1 STEEPNESS RATIO ARE TO BE CONSTRUCTED BY THE PLACEMENT OF SOIL AT SUFFICIENT DISTANCE BEYOND THE PROPOSED FINISH SLOPE TO ALLOW COMPACTION EQUIPMENT TO BE OPERATED AT THE OUTER LIMITS OF THE FINAL SLOPE SURFACE. THE EXCESS
FILLS TO BE REMOVED PRIOR TO COMPLETION OF ROUGH GRADING. OTHER CONSTRUCTION
PROCEDURES MAY BE USED WHEN IT IS DEMONSTRATED TO THE SATISFACTION OF THE BUILDING
OFFICIAL THAT THE ANGLE OF SLOPE, CONSTRUCTION METHOD AND OTHER FACTS WILL HAVE
EQUIVALENT EFFECT.
NOTICE TO CONTRACTOR
1. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED
CONSTRUCTION PRACTICES. CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE
AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT
THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT LIMITED TO NORMAL
WORKING HOURS.
2. THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT AT LEAST 48 HOURS PRIOR TO
COMMENCEMENT OF EXCAVATION TO ARRANGE FOR FIELD LOCATIONS OF UTILITY LINES. CALL
1-800-422-4133 FOR THIS SERVICE. ANY UTILITY NOT SUBSCRIBING TO THIS SERVICE SHALL BE
CONTACTED DIRECTLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE
WHETHER AL UTILITIES HAVE BEEN NOTIFIED.
3. THE CONTRACTOR SHALL OBTAIN A PERMIT FROM THE DEPARTMENT OF PUBLIC WORKS PRIOR TO
PERFORMING ANY WORK IN THE CITY RIGHT OF WAY.
4. ALL CONSTRUCTION ACTIVITIES WITHIN CITY RIGHT OF WAY SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE AMERICAN PUBLIC WORKS ASSOCIATION STANDARD SPECIFICATIONS
FOR PUBLIC WORKS CONSTRUCTION AND THE CITY OF LONG BEACH "BROWN BOOK".
5. ALL TRAFFIC CONTROL, BARRICADING, AND CONSTRUCTION SIGNING SHALL BE IN CONFORMANCE WITH THE WORK AREA TRAFFIC CONTROL HANDBOOK (WATCH), DETOUR SIGNS SHALL BE POSTED
ON WOOD OR METAL POSTS. SIGNS SHALL NOT BE POSTED ON ANY TREE OR TRAFFIC SIGN.
6. NO WATER SHALL BE TAKEN FROM FIRE HYDRANTS WITHOUT APPROVAL FORM THE
JURISDICTIONAL WATER AGENCY.
7. DUST SHALL BE CONTROLLED BY SWEEPING AND WATERING.
8. ALL NONSTORMWATER DISCHARGES FROM THE CONSTRUCTION PHASE ACTIVITIES AT THE
PROJECT (I.E. MIXING AND CLEANING OF CONSTRUCTION MATERIALS, CONCRETE AND PLASTER WASHOUT, DISPOSAL, OF PAINTS, ADHESIVES, SOLVENTS, AND LANDSCAPE PRODUCTS) SHALL BE
PROHIBITED FROM ENTERING THE PUBLIC STORM DRAINAGE SYSTEM (INCLUDING MUNICIPAL
STREETS, CATCH BASINS, CURBS, GUTTERS, DITCHES, MAN-MADE CHANNELS OR UNDERGROUND
STORM DRAINS).
STORMWATER CONSTRUCTION NOTES
MINIMUM BMP REQUIREMENTS FOR CONSTRUCTION ACTIVITIES FOR ALL DEVELOPMENT
CONSTRUCTION PROJECTS.
1. ERODED SEDIMENTS AND OTHER POLLUTANTS MUST BE RETAINED ON SITE AND MAY NOT BE
TRANSPORTED FROM THE STIE VIA SHEET FLOW, SWALES, AREA DRAINS, NATURAL DRAINAGE
COURSES OR WIND.
2. STOCKPILES OR EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE PROTECTED
FROM BEING TRANSPORTED FROM THE SITE BY THE FORCE OF WIND AND WATER.
3. FUELS, OILS, SOLVENTS AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH THEIR LISTING AND ARE NOT TO CONTAMINATE THE SOIL AND SURFACE WATERS. ALL APPROVED
STORAGE CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS MUST BE CLEANED
UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED INTO
THE DRAINAGE SYSTEM.
4. NON-STORMWATER RUNOFF FROM EQUIPMENT AND VEHICLE WASHING AND ANY OTHER ACTIVITY
SHALL BE CONTAINED AT THE PROJECT SITE.
5. EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY OTHER
DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES ON SITE UNTIL
THEY CAN BE DISPOSED OF AS SOLID WASTE.
6. TRASH AND CONSTRUCTION RELATED SOLID WASTES MUST BE DEPOSITED INTO A COVERED
RECEPTACLE TO PREVENT CONTAMINATION OR RAINWATER AND DISPERSAL BY WIND.
7. SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC.
THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTS
FROM BEING DEPOSITED INTO THE PUBLIC WAY. ACCIDENTAL DEPOSITIONS MUST BE SWEPT UP
IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR OTHER MEANS.
8. ANY SLOPE WITH DISTURBED SOILS OR DENUDED OF VEGETATION MUST BE STABILIZED SO AS ITO
INHIBIT EROSION BY WIND AND WATER.
9. ADDITIONAL BMPS WILL BE IMPLEMENTED AS DEEMED NECESSARY BY CITY INSPECTORS.
WM-1 MATERIAL STORAGE AND DELIVERY
PROVIDE A MATERIAL STORAGE AREA WITH SECONDARY CONTAINMENT AND/OR WEATHER
PROTECTION. NOTE THE MAINTENANCE PRACTICES AND SCHEDULE PROPOSED FOR THIS AREA.
WM-2 MATERIAL USE
HAZARDOUS MATERIALS, FERTILIZERS, PESTICIDES, PLASTERS, SOLVENTS, PAINTS, AND OTHER
COMPOUNDS MUST BE PROPERLY HANDLED IN ORDER TO REDUCE THE RISK OF POLLUTION OR
CONTAMINATION. TRAINING AND INFORMATION ON PROCEDURES FOR THE PROPER USE OF ALL
MATERIALS MUST BE AVAILABLE TO THE EMPLOYEES THAT APPLY SUCH MATERIALS.
WM-4 SPILL PREVENTION AND CONTROL
IDENTIFY SPILL PREVENTION AND CONTROL MEASURES THAT WILL BE TAKEN FOR ALL PROPOSED
MATERIALS. IDENTIFY THE METHODS, BY WHICH ACCIDENTAL SPILLS WILL BE CLEANED AND
PROPERLY DISPOSED OF.
WM-5 SOLID WASTE MANAGEMENT
PROVIDE DESIGNATED WASTE COLLECTION AREAS AND CONTAINERS. ARRANGE FOR REGULAR
DISPOSAL. PROVIDE COVERED STORAGE WITH SECONDARY CONTAINMENT. CONTAINERS ARE
REQUIRED TO PROTECT WASTE FROM RAIN TO PREVENT WATER POLLUTION AND PREVENT WIND
DISPERSAL.
WM-6 HAZARDOUS WASTE MANAGEMENT
HAZARDOUS MATERIALS MUST BE DISPOSED OF IN ACCORDANCE WITH STATE AND FEDERAL
REGULATIONS. IDENTIFY THE PROPOSED METHODS OF DISPOSAL AND ANY SPECIAL HANDLING
CONTRACTS THAT MAY BE APPLICABLE.
WM-7 CONTAMINATED SOIL MANAGEMENT
PREVENT OR REDUCE THE DISCHARGE OF POLLUTANTS TO STORMWATER FROM CONTAMINATED SOIL AND HIGHLY ACIDIC OR ALKALINE SOILS BY CONDUCTING PRECONSTRUCTION SURVEYS, INSPECTING
EXCAVATIONS REGULARLY, AND PREMEDITATING CONTAMINATED SOIL PROMPTLY.
WM-8 CONCRETE WASTE MANAGEMENT
STORE DRY AND WET MATERIALS UNDER COVER. AVOID ONSITE WASHOUT EXCEPT IN DESIGNATED AREAS AWAY FROM DRAINS, DITCHES, STREETS, AND STREAMS,. CONCRETE WASTE DEPOSITED ON SITE SHALL SET-UP, BE BROKEN APART, AND DISPOSED OF PROPERLY. CONTAINMENT AND PROPER
DISPOSAL IS REQUIRED FOR ALL CONCRETE WASTE.
WM-9 SANITARY/SEPTIC WASTE MANAGEMENT
UNTREATED RAW WASTEWATER IS NOT TO BE DISCHARGED OR BURIED. SANITARY SEWER FACILITIES
ON SITE ARE REQUIRED TO BE IN COMPLIANCE WITH LOCAL HEALTH AGENCY REQUIREMENTS.
SANITARY OR SEPTIC WASTES MUST BE TREATED OR DISPOSED OF IN ACCORDANCE WITH STATE AND
LOCAL REQUIREMENTS.
TC-1 STABILIZED CONSTRUCTION ENTRANCE
A STABILIZED ENTRANCE IS REQUIRED FOR ALL CONSTRUCTION SITES TO ENSURE THAT DIRT AND
DEBRIS ARE NOT TRACKED ONTO THE ROAD OR ADJACENT PROPERTY. MAINTENANCE OF SUCH A
SYSTEM IS REQUIRED FOR THE DURATION OF THE PROJECT. SUCH STABILIZATION MAY BE OF ROCK OR
PAVED.
SE-1 SILT FENCE / SE-3 SEDIMENT TRAP / SE-8 SAND BAGS
ERODED SEDIMENTS MUST BE RETAINED ONSITE AND NOT PERMITTED TO ENTER THE DRAINAGE
SYSTEM. MAY BE WAIVED AT THE SOLE DISCRETION OF THE CITY INSPECTOR IF OTHER EROSION
CONTROL BMPS ARE DEEMED SUFFICIENT.
GENERAL NOTES SCALE: 1" = 15'-0" 6
C100
QUEEN MARY VILLAGE: CIVIL PLANS
1 3 4VICINITY MAP SHEET INDEX
SHEET DESCRIPTION
GRADING INFORMATION2 PROJECT DIRECTORYPROJECT DATA1 3 4 5
PROJECT LOCATION
QUEEN MARY VILLAGE
LONG BEACH, CA 90802
LEGAL DESCRIPTION
ASSESSOR ID#: 7436-021-907
PROJECT INFORMATION
PARCEL 1: QUEEN MARY LAND AREA, 43.378 ACRES
OWNER
CITY OF LONG BEACH
PROJECT DESIGNER/ARCHITECT
RA-DA
7352 NORTON AVE
WEST HOLLYWOOD, CA 90046
323.851.4040
CIVIL ENGINEER
JAMES TUCHSCHER, P.E.
TEG, INC.
130 PINE AVE, 3RD FLOOR
LONG BEACH, CA 90802
310.613.9980
C100 TITLE SHEET
C200 EXISTING SITE PLAN
C300 GRADING PLAN
SOILS GRADING QUANTITIES (CU.YD.)
CUT 624.5 CU.YD.
FILL 298.0 CU.YD.
TOTAL 922.5 CU.YD.
IMPORT 0.0 CU.YD.
EXPORT 326.5 CU.YD.
C201 DEMOLITION/UTILITY PLAN
C301 CUT/FILL DIAGRAM PLAN
C400 EROSION CONTROL PLAN
240322
Issue Date
B
ID
S
ET
2.
.2
DRAWING REF.
R E
F
C I T
Y
G
R I D
SHEET
OF
F I E
O
K
S C
A L E
P A
G E
G R
A P
H I C
A S
B
U I L T
D A
T E
N o
S H
E E
T D
E S
C R
I P
T I O
N
R E
V I S
I O
N S
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
D R
A F
T I N
G
C
H E
D E
S I G
N
C
H E
A P
P R
O V
A L
NOTE:
MUNIS Project #
Phase# ____ / Rebid:____
RA-DA
7523 NORTON AVE.
WEST HOLLYWOOD CA 90046
T. 323-851-4040
RANIA@RA-DA.COM
WWW.RA-DA.COM
DRAWING NUMBER
1/21/2025 8:28:24 AM
AGGREGATE BASE GRADING QUANTITIES (CU.YD.)
CUT 0.0 CU.YD.
FILL 253.1 CU.YD.
IMPORT 253.1 CU.YD.
B-4853
02/17/2025
TH
ER
C-2 SURVEY
Q U E E N S H W Y
Q U
EE
N
M A
R Y
VI
LL
A G
E D
EM
O
LI
TI
O N
Q ue en s
H w y, L on g
B ea ch , C
A
EXISTING SITE PLAN SCALE: 1" = 15'-0" 1
C200
2 6
G R
A P
H I C
10/18/2024 11:58:27 AM
Ex is ti ng
S it e P la n
Issue Date
B
ID
S
ET
2.
.2
DRAWING REF.
R E
F
C I T
Y
G
R I D
SHEET
OF
F I E
O
K
S C
A L E
P A
G E
G R
A P
H I C
A S
B
U I L T
D A
T E
N o
S H
E E
T D
E S
C R
I P
T I O
N
R E
V I S
I O
N S
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
D R
A F
T I N
G
C
H E
D E
S I G
N
C
H E
A P
P R
O V
A L
NOTE:
MUNIS Project #
Phase# ____ / Rebid:____
RA-DA
7523 NORTON AVE.
WEST HOLLYWOOD CA 90046
T. 323-851-4040
RANIA@RA-DA.COM
WWW.RA-DA.COM
DRAWING NUMBER
1/21/2025 8:28:24 AM
B-4853
LEGEND
EXISTING MAJOR GRADE CONTOUR
(101') EXISTING MINOR GRADE CONTOUR
(100')
EXISTING WALL TO BE DEMO'ED
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMO'ED
STREET LIGHT
GAS VALVE
FIRE HYDRANT
SIGN
FENCE
FDC
DEMOLITION NOTES
IRRIGATION SYSTEM
VAULT
ELECTRICAL VAULT/PULL BOX
LIGHT
SANITARY SEWER MANHOLE
STORM DRAIN MANHOLE
STREET LIGHT PULL BOX
WATER METER
WATER VALVE
A.C.
(2 0'
(1 6'
(1 7'
(1 8'
(1 9'
(1 6'
(16')
(1 6'
(16')
(16
(16')
(16')
(16')
(16')
STORM DRAIN CATCH BASIN TO BE ADJUSTED TO
GRADE
(16')
(17')
(18')
(19')
(20')
EXISTING BUILDING FOUNDATION TO BE DEMO'ED,
OUTLINE & DEPTH TO BE VERIFIED IN THE FIELD
PROTECTION NOTES
EXISTING PLANTER WALL/CURB TO BE DEMO'ED
D1
D10
D1
D10
D10
D2
D2
D2
D2
D2D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
EXISTING A.C. TO BE DEMO'ED
FIRELINE WATER SERVICE KILL TAP CLASS A OR C-34
CONTRACTOR SHALL PERFORM KILL TAPS FOR
SERVICES THAT WILL NOT BE USED
EXISTING ELECTRICAL VAULT/PULL BOX TO BE
DEMO'ED
D4
D5
D5
D5
D5
D5
EXISTING LIGHT TO BE DEMO'ED
D6 D6
D6
D6
EXISTING WATER VALVE TO BE DEMO'ED PER WDS-127
D7
D7
D6
EXISTING GAS VALVE TO BE DEMO'ED
EXISTING IRRIGATION SYSTEM TO BE DEMO'ED
D8
D7
D9
D6
D5
D9
D7
EXISTING UTILITY LINES ENCOUNTERED DURING
EXCAVATION TO A DEPTH OF 24" TO BE TRACED AND
CUT BACK TO METER
EXISTING STAIRS AND ASSOCIATED FOOTINGS TO BE
DEMO'ED
D12
D12
EXISTING STREET LIGHT PULL BOX TO REMAIN
EXISTING STAIRS TO REMAIN
PAVEMENT TO REMAIN
EXISTING PAVEMENT TO REMAIN
EXISTING CONCRETE DRIVEWAY APRON TO REMAIN17
EXISTING CURB & GUTTER TO REMAIN
EXISTING LANDSCAPING TO REMAIN
EXISTING CONCRETE TO BE DEMO'ED
D13
D13
(16')
(1 9'
D1
D1
D10
D1
D1
D1
D1
EXISTING POSTS TO BE DEMO'ED
D14
TYP.
D14TYP.
D14TYP.
EXISTING WALL TO REMAIN
LIMIT OF WORK
EXISTING TREE TO BE DEMO'ED
EXISTING TREE TO REMAIN
D15
D15
D15
D15
LIMIT OF WORK
LI
M
IT
O
F W
OR
K
LIMIT OF WORK
LI
M
IT
O
F W
OR
K
LIMIT OF WORK
LIMIT OF W
ORK
D13
EXISTING RAMP TO BE DEMO'ED
D16D16
D2
D10
D10
D1
D1
D1
D13
D14 TYP.
D13
D13
D13
D13
D1
D1
D10
D1
D1
D13
EXISTING GREASE TRAP TO BE DEMO'ED
D17
EXISTING PILASTERS & FENCING TO BE DEMO'ED
D18
D12
D7
D3
D12
D13
EXISTING FENCE TO BE DEMO'ED
D11
D11
EXISTING SIGN TO REMAIN
D12
D15
EXISTING LANDSCAPING AND TREES TO BE DEMO'ED
19D19
D2
D15
D15
EXISTING SEWER NOTE
EXISTING SEWER LINES TO BE CAPPED 2' OUTSIDE OF THE PROPERTY
BOUNDS, WITHIN THE RIGHT OF WAY
WATER/SEWER NOTES
1. FOR THE INSTALLATION OF POTABLE WATER SERVICES 3 INCHES AND
SMALLER, DEVELOPER OR CONTRACTOR SHALL FOLLOW INSTRUCTIONS AS
LISTED AT: HTTPS://WWW.LBUTILITIES.ORG/DEVELOPMENT-SERVICES/WATER
-DEVELOPMENT-SERVICES/INSTALL-NEW-POTABLE-WATER-SERVICE-
CONNECTION SCROLL DOWN AND CLICK ON DOMESTIC (3” OR SMALLER).
2. FOR THE INSTALLATION OF POTABLE WATER SERVICES 4 INCHES AND
LARGER, DEVELOPER OR CONTRACTOR SHALL FOLLOW INSTRUCTIONS AS
LISTED AT:
HTTPS://WWW.LBUTILITIES.ORG/DEVELOPMENT-SERVICES/WATER-
DEVELOPMENT-SERVICES/INSTALL-NEW-POTABLE-WATER-SERVICE-
CONNECTION SCROLL DOWN AND CLICK ON DOMESTIC (LARGER THAN 3").
3. FOR THE INSTALLATION OF FIRELINE SERVICES 4 INCHES AND GREATER,
DEVELOPER OR CONTRACTOR SHALL FOLLOW INSTRUCTIONS AS LISTED AT:
HTTPS://WWW.LBUTILITIES.ORG/DEVELOPMENT-SERVICES/WATER-
DEVELOPMENT-SERVICES/INSTALL-NEW-POTABLE-WATER-SERVICE-
CONNECTION SCROLL DOWN AND CLICK ON FIRE SERVICE (LARGER THAN 4").
4. THE INSTALLATION OF SEWER SERVICE CONNECTIONS AND CAPPING OF
EXISTING SEWER LATERALS REQUIRES A SEWER PERMIT AND INSPECTION BY
LBUD. CONTRACTOR SHALL FOLLOW INSTRUCTIONS LISTED AT:
HTTPS://WWW.LBUTILITIES.ORG/DEVELOPMENT-SERVICES/WATER-
DEVELOPMENT-SERVICES/INSTALL-NEW-POTABLE-WATER-SERVICE-
CONNECTION.
5. ACTUAL LOCATION OF CLEANOUT SHALL BE VERIFIED IN THE FIELD WITH
LBUD INSPECTOR PRIOR TO INSTALLATION.
6. ALL SEWER ABANDONMENTS AND WATER SERVICE KILL TAPS SHALL BE
PERFORMED PRIOR TO SITE DEMOLITION AND NEW INSTALLATIONS OF ANY
KIND.
LBUD DEMO NOTES
1. KILL TAP SERVICE TO BE PERFORMED BY LBUD. CONTACT CITY OF LONG
BEACH CUSTOMER SERVICE AT 562-570-5991 TO ORDER. SEE WATER/SEWER
NOTE 6.
EXISTING 4"Ø CI GRAVITY SEWER MAIN
(SC-0052-LBUD) TO REMAIN
PROTECTION NOTES
EXISTING TRANSFORMER TO REMAIN
EXISTING FIRE HYDRANT TO REMAIN
EXISTING WALL TO REMAIN
EXISTING CATCH BASIN TO BE ADJUSTED TO GRADE,
CONTRACTOR TO VERIFY LOCATION AND ROUTING OF
EXISTING STORM DRAIN SYSTEM VIA CCTV TO
PROTECT IN PLACE TO DISCHARGE LOCATION
EXISTING VAULT TO REMAIN
EXISTING IRRIGATION SYSTEM TO REMAIN
EXISTING STREET LIGHT TO REMAIN
EXISTING STORM DRAIN MANHOLE TO REMAIN
EXISTING SANITARY SEWER MANHOLE TO REMAIN
EXISTING ELECTRICAL VAULT/PULL BOX TO REMAIN
EXISTING LIGHT TO REMAIN
EXISTING WATER VALVE TO REMAIN
EXISTING STAIRS TO REMAIN
EXISTING 6"Ø WATER LATERAL TO REMAIN
EXISTING 8"Ø WATER LATERAL TO REMAIN
EXISTING 10"Ø AC PRESSURED SEWER MAIN
(SC-0052-LBUD) TO REMAIN
EXISTING 8"Ø VCP GRAVITY SEWER MAIN
(SC-0052-LBUD) TO REMAIN
EXISTING (2) 2" LIVE WATER SERVICE SHALL BE SHUT
OFF (METER AND METER BOX REMAIN PENDING KILL
TAP). KILL TAP SERVICE AND METER REMOVAL SHALL
BE PERFORMED BY LBUD. CONTACT CITY AT
562-570-5991 TO REQUEST REMOVAL.
D20
EXISTING BACFKLOW AND DCDA TO BE DEMO'ED
D21
EXISTING FIRE DEPARTMENT CONNECTION (FDC) TO
REMAIN
D6
D2 D2
EXISTING CONCRETE SWALE TO BE DEMO'ED
D22
EXISTING PILASTER TO BE CUT DOWN TO HEIGHT OF
ADJACENT WALL
D20
KILL TAP AT TEE TO PROTECT IN PLACE EXISTING
WATER SERVICE TO FIRE HYDRANT
D12
EXISTING FENCING TO BE DEMO'ED
EXISTING PLANTING TO BE DEMO'ED
D24 D23
DEMOLITION
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D12
D13
D14
D15
D16
D17
D18
D19
D20
D21
D22
D23
D24
D em ol it io n/
U ti lit y
P la n
Q U
EE
N
M A
R Y
VI
LL
A G
E D
EM
O
LI
TI
O N
Q ue en s
H w y, L on g
B ea ch , C
A
DEMOLITION/UTILITY PLAN 1
C201
SCALE: 1" = 15'-0"
G R
A P
H I C
Issue Date
B
ID
S
ET
2.
.2
DRAWING REF.
R E
F
C I T
Y
G
R I D
SHEET
OF
F I E
O
K
S C
A L E
P A
G E
G R
A P
H I C
A S
B
U I L T
D A
T E
N o
S H
E E
T D
E S
C R
I P
T I O
N
R E
V I S
I O
N S
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
D R
A F
T I N
G
C
H E
D E
S I G
N
C
H E
A P
P R
O V
A L
NOTE:
MUNIS Project #
Phase# ____ / Rebid:____
RA-DA
7523 NORTON AVE.
WEST HOLLYWOOD CA 90046
T. 323-851-4040
RANIA@RA-DA.COM
WWW.RA-DA.COM
DRAWING NUMBER
1/21/2025 8:28:24 AM
B-4853
TYPICAL RETAINING WALL DETAIL A
M A
X.
24"
2 BARS @ TOP
WATERPROOFING
DRAINAGE SHEET
8"CMU WALL
W/ #4 @ 16" O.C. VERTICAL
& #4 @ 24" O.C. HORIZONTAL
OKAY TO SUBSTITUTE
8" CONCRETE WALL W/
#4 @ 12" O.C. BOTH WAYS
1 CU.FT./FT. OF 34" CRUSHED
GRAVEL WRAPPED IN
MIRAFI FILTER FABRIC
3"Ø WEEPHOLES @ 48" O.C.
24" CONTINUOUS FOOTING
3000 PSI W/ 18" INTO
UNDISTURBED SOIL
#4 DOWELS @ 16" O.C.
#4 @ 16" O.C. BOTH WAYS
TOP MAT
3" C
LR
3'-0" MAXIMUM
RETAINING WALL
1/4
PL14 "x4"x4"
(4) 38"Øx4" TITEN HD BOLTS
PIPE RAIL PER ARCH PLANS
T.W. & F.G.
F.G.
CATCH BASIN STENCIL B
#4 @ 16" O.C. TRANSVERSE
#3 NOSE BAR
(TYP)
#4 T&B
#4 @ 16" O.C.
4" M
IN
8"
STAIR ON GRADE TYPICAL DETAIL C
GRADING
LEGEND
(1 6'
(16')
(16')
(16')
(17')
(18')
(19')
(2 0'
CONSTRUCTION NOTES
LI
M
IT
O
F W
OR
K
' 19
20'
CALLOUT LEGEND
EXISTING SURFACE ELEVATION
EXISTING GRADE ELEVATION
FINISHED SURFACE ELEVATION
FINISHED GRADE ELEVATION
ELEVATION AT TOP OF WALL
E.S.
E.G.
F.S.
F.G.
T.W.
EXISTING MAJOR GRADE CONTOUR
(101') EXISTING MINOR GRADE CONTOUR
(100')
PROPOSED WALL
PROPOSED CONSTRUCTION
STREET LIGHT
FIRE HYDRANT
SIGN
IRRIGATION SYSTEM
VAULT
ELECTRICAL TRANSFORMER
SANITARY SEWER MANHOLE
STORM DRAIN MANHOLE
STREET LIGHT PULL BOX
WATER METER
WATER VALVE
STORM DRAIN CATCH BASIN TO BE ADJUSTED TO
GRADE
PAVEMENT TO REMAIN
EXISTING WALL TO REMAIN
LIMIT OF WORK
CONCRETE APRON TO REMAIN
PROPOSED MAJOR GRADE CONTOUR
101' PROPOSED MINOR GRADE CONTOUR
(100') EXISTING MAJOR GRADE CONTOUR TO BE REMOVED
(101') EXISTING MINOR GRADE CONTOUR TO BE REMOVED
100'
A C300
A C300
A C300
A C300
1 RETAINING WALL PER DETAIL A/C300
2 PIPE RAILING TO BE ANCHORED TO EXISTING RETAINING WALL
3 2" A.C. OVER 4" COMPACTED AGGREGATE BASE (C.A.B.)
Q U E E N S H W Y
-2.0%
-2.0%
-2.0%
-0 .9
-1.1%
-0.7% -0.9%
-3.0%
-5.3%
-50.0%
-50.6%
'F.G. 16.34'
F.G. 19.55'
F.G. 19.75'
F.G. 16.85'
F.G. 16.74'
F.G. 16.47' F.G. 16.83'
F.G. 16.59'
(16')
(16')
(1 9'
(19')
(2 0'
) (20')
(1 6'
(16')
F.G. 16.55' F.G. 16.20'
F.G. 16.20'
F.G. 19.00'
F.G. 18.70'
F.G. 18.52'
F.G. 18.70'
F.G. 18.03'
E.S. 21.00'
E.S. 20.83'
E.S. 20.41'
(21')
(19')
(17')
(1 8')
F.S. 15.72'
F.S. 15.76'
F.S. 16.04'
F.G. 16.37'
E.S. 16.27'
E.S. 16.46'
E.S. 16.38'
F.G. 16.21'
E.S. 15.53'
E.S. 15.57'
E.S. 15.91'
E.S. 15.05'
F.G. 16.46' E.S. 15.79'
E.S. 16.22'
F.G. 15.42' -0 .4
-1.1%
-0.1%
-1.1%
-1.0%
-2.4%
-6.2%
-2.9%
-1 2.
8%
-3 .0
-2.1%
-1.5%
-0.5%
-1 .6
-0 .4
-1 .3
-1 .3
-2.8%
-2.2%
-3 .0
-1.5%
-2 .7
F.G. 16.46'
F.G. 16.77'
F.G. 16.54'
E.G. 20.13'
E.G. 19.92'
(16')
F.G. 16.04'
F.G. 16.87'
F.G. 16.87'
T.G. 16.71'
F.G. 16.77'
T.G. 15.78'
-1 .1
4 EXISTING CATCH BASIN TO BE ADJUSTED TO GRADE
A C300
LIMIT OF WORK
LIM
IT OF W
ORK
LIMIT OF WORK
LI
M
IT
O
F W
OR
K
LIMIT OF WORK
LIMIT OF WORK
F.G. 19.31'
F.G. 19.48'
-2.4%
W = 4.00'
X = 4.00'
X = 6.05'
Y = 7.20'
Q = 4.00'
'-8.3%
-2.0% F.S. 15.39'
F.S. 14.71'
CITY OF LONG BEACH STANDARD PLAN NO. 122,
CURB RAMP - CASE D (X = 4.00' & 6.05', W = 4.00', Y = 7.20', Q = 4.00')
16'
6 CONCRETE, CAST-IN-PLACE STAIRS ON GRADE PER DETAIL C/C300
GRADING PLAN 1
C300
SCALE: 1" = 15'-0"
G ra di ng
P la n
Q U
EE
N
M A
R Y
VI
LL
A G
E D
EM
O
LI
TI
O N
Q ue en s
H w y, L on g
B ea ch , C
A
G R
A P
H I C
10/18/2024 11:58:27 AMIssue Date
B
ID
S
ET
2.
.2
DRAWING REF.
R E
F
C I T
Y
G
R I D
SHEET
OF
F I E
O
K
S C
A L E
P A
G E
G R
A P
H I C
A S
B
U I L T
D A
T E
N o
S H
E E
T D
E S
C R
I P
T I O
N
R E
V I S
I O
N S
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
D R
A F
T I N
G
C
H E
D E
S I G
N
C
H E
A P
P R
O V
A L
NOTE:
MUNIS Project #
Phase# ____ / Rebid:____
RA-DA
7523 NORTON AVE.
WEST HOLLYWOOD CA 90046
T. 323-851-4040
RANIA@RA-DA.COM
WWW.RA-DA.COM
DRAWING NUMBER
1/21/2025 8:28:24 AM
B-4853
ER
CUT/FILL DIAGRAM
SOILS GRADING SUMMARY
TOTAL
CUT 624.5 CU.YD.
FILL 298.0 CU.YD.
TOTAL 922.5 CU.YD.
326.5 CU.YD. EXPORT
LEGEND
EXISTING MAJOR GRADE CONTOUR
(101') EXISTING MINOR GRADE CONTOUR
(100')
FIRE HYDRANT
SIGN
VAULT
STORM DRAIN MANHOLE
WATER METER
WATER VALVE
STORM DRAIN CATCH BASIN TO BE ADJUSTED TO
GRADE
FILL
LIMIT OF WORK
CUT
(2 0'
(16')
(16')
(17')
(18')
(19')
(1 6'
(16')
PROPOSED WALL
STREET LIGHT
IRRIGATION SYSTEM
ELECTRICAL TRANSFORMER
SANITARY SEWER MANHOLE
STREET LIGHT PULL BOX
EXISTING WALL TO REMAIN
Q U E E N S H W Y
LIMIT OF WORK
LI
M
IT
O
F W
OR
K
LIMIT OF WORK
LI
M
IT
O
F W
OR
K
LIMIT OF WORK
LIM
IT OF W
ORK
STOCKPILING LOCATION:
33.75195°, -118.19113°
AGGREGATE BASE GRADING SUMMARY
TOTAL
CUT 0.0 CU.YD.
FILL 253.1 CU.YD.
TOTAL 253.1 CU.YD.
253.1 CU.YD. IMPORT
CUT/FILL DIAGRAM PLAN 1
C301
SCALE: 1" = 15'-0"
C ut
/F ill
D ia gr am
P la n
Q U
EE
N
M A
R Y
VI
LL
A G
E D
EM
O
LI
TI
O N
Q ue en s
H w y, L on g
B ea ch , C
A
G R
A P
H I C
10/18/2024 11:58:27 AMIssue Date
B
ID
S
ET
2.
.2
DRAWING REF.
R E
F
C I T
Y
G
R I D
SHEET
OF
F I E
O
K
S C
A L E
P A
G E
G R
A P
H I C
A S
B
U I L T
D A
T E
N o
S H
E E
T D
E S
C R
I P
T I O
N
R E
V I S
I O
N S
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
D R
A F
T I N
G
C
H E
D E
S I G
N
C
H E
A P
P R
O V
A L
NOTE:
MUNIS Project #
Phase# ____ / Rebid:____
RA-DA
7523 NORTON AVE.
WEST HOLLYWOOD CA 90046
T. 323-851-4040
RANIA@RA-DA.COM
WWW.RA-DA.COM
DRAWING NUMBER
1/21/2025 8:28:24 AM
B-4853
ER
EROSION CONTROL PLANS
EROSION CONTROL NOTESLEGEND
Q U E E N S H W Y
CONSTRUCTION NOTES
1 SC-5 INLET PROTECTION
2 TC-1 STABILIZED CONSTRUCTION ENTRANCE (ESC 24)
3 CONSTRUCTION GATE
4 SE-8 SANDBAG BARRIER (ESC 52)
SE-8 SANDBAG BARRIER (ESC 52)
TC-1 STABILIZED CONSTRUCTION ENTRANCE (ESC
24)
CONSTRUCTION GATE
1. ALL CONSTRUCTION DEBRIS MUST BE CONTAINERIZED AT ALL TIMES.
2. DUST CONTROL MEASURES SHALL BE MAINTAINED THROUGHOUT THE
DURATION OF THE PROJECT.
3. PRESERVATION OF EXISTING VEGETATION MINIMIZES THE POTENTIAL
OR REMOVING OR INJURING EXISTING TREES, VINES, SHRUBS, AND/OR
GRASSES THAT SERVE AS EROSION CONTROLS.
4. FOR ADDITIONAL WIND PREVENTION STRATEGIES, SEE WE-1.
5. THE FOLLOWING ADDITIONAL BMPS ARE TO BE INCORPORATED:
ESC 1 SCHEDULING
ESC 21 DUST CONTROL
ESC 56 SEDIMENT BASIN
NS-1 WATER CONSERVATION PRACTICES
NS-2 DEWATERING OPERATIONS
WM-3 STOCKPILE MANAGEMENT
SC-1 NON-STORMWATER DISCHARGES TO DRAINS
SC-2 VEHICLE EQUIPMENT FUELING
SC-3 VEHICLE AND EQUIPMENT WASHING AND STEAM CLEANING
SC-4 VEHICLE AND EQUIPMENT MAINTENANCE AND REPAIR
SC-5 OUTDOOR LOADING- UNLOADING OF MATERIALS
SC-6 OUTDOOR CONTAINER STORAGE OF LIQUIDS
SC-7 OUTDOOR PROCESS EQUIPMENT
SC-8 OUTDOOR STORAGE OF RAW MATERIALS
SC-9 WASTE HANDLING AND DISPOSAL
SC-10 CONTAMINATED OR ERODIBLE SURFACE AREAS
SC-11 BUILDING AND GROUNDS MAINTENANCE
SC-12 BUILDING REPAIR, REMODELING AND CONSTRUCTION
SC-13 OVER-WATER ACTIVITIES
SC-14 EMPLOYEE TRAINING
EXISTING STRUCTURE OUTLINE TO BE DEMO'ED
(20')
(1 6')
(17')
(1 8'
(19')
(21')
(1 6'
(1 7'
(1 8'
(1 9'
(16')
(16')
(16')
(16')
(16')
(1 6'
(16')
(16')
(16')
(16')
(17')
(18')
(19')
(20') (1
6'
Er os io n
C on tr ol
P la n B
ID
S
ET
2.
.2
DRAWING REF.
R E
F
C I T
Y
G
R I D
SHEET
OF
F I E
O
K
S C
A L E
P A
G E
G R
A P
H I C
A S
B
U I L T
D A
T E
N o
S H
E E
T D
E S
C R
I P
T I O
N
R E
V I S
I O
N S
D E
S I G
N E
D
B
Y
D R
A W
N
B
Y
D R
A F
T I N
G
C
H E
D E
S I G
N
C
H E
A P
P R
O V
A L
NOTE:
MUNIS Project #
Phase# ____ / Rebid:____
RA-DA
7523 NORTON AVE.
WEST HOLLYWOOD CA 90046
T. 323-851-4040
RANIA@RA-DA.COM
WWW.RA-DA.COM
DRAWING NUMBER
1/21/2025 8:28:24 AM
EROSION CONTROL PLAN 1
C400
SCALE: 1" = 15'-0"
Q U
EE
N
M A
R Y
VI
LL
A G
E D
EM
O
LI
TI
O N
Q ue en s
H w y, L on g
B ea ch , C
A
G R
A P
H I C
Issue Date
B-4853
D- 101
A101
1 Ref
R e f
1 Ref
R e f
F00
Room nameRoom nameRoom nameRoom name
101101101101
150 SF150 SF150 SF150 SF
A101
SIM
View Name 1/8" = 1'-0"
DOOR NUMBER, SEE SCHEDULE FOR MORE
INFORMATION
INTERIOR ELEVATION INDICATOR
LIGHTING FIXTURE NUMBER, SEE SCHEDULE
ROOM NAME & NUMBER, SEE SCHEDULE FOR
FINISHES
FLOOR TYPE
DRAWING TITLE & REFERENCE INDICATOR
A.F.F.
1i
1'-0"
CEILING TYPE & HEIGHT
SECTION INDICATOR
ELEVATION HEIGHT
A101
Ref
R e f
R e f
Ref
EXTERIOR ELEVATION INDICATOR
1 TAG FOR ELEMENT, REFERS TO KEYNOTE
LEGEND ON DRAWINGS
CONC
PT WALL FINISH TAG, IN ELEVATIONS
1i PLUMBING FIXTURE AND SPECIALTY
EQUIPMENT TAG
1t WINDOW TAG
1i WALL TAG
EARTH
SAND FILL
GRAVEL FILL
CONCRETE
FINISH WOOD
CONTINUOUS WOOD BLKG.
WOOD BLKG OR SHIM
RIGID INSULATION
BATT OR BLANKET INSULATION
CARPET IN SECTION
GYPSUM PLASTER BOARD
PLYWOOD OR WOOD VENEER
SEALANT WITH BACKER ROD
EPOXY FLOOR
GRASS
MARMOLEUM
FLOOR
DRAWING REF.
R E
F
C
IT
Y G
R
ID
SHEET
OF
F
IE
L D
B O
O K
S C
A L E
P A
G E
G R
A P
H
IC
A S
-B U
IL
T
D A
T E
N o
S
H E
E T
D E
S C
R
IP
T
IO
N
R E
V
IS
IO
N
S D
E S
IG
N
E D
B Y
D R
A W
N B
Y
D R
A F
T
IN
G C
H E
C K
B Y
D E
S
IG
N C
H E
C K
B Y
A P
P R
O V
A L
NOTE:
MUNIS Project #
Phase# ____ / Rebid:____
RA-DA
7523 NORTON AVE.
WEST HOLLYWOOD CA 90046
T. 323-851-4040
RANIA@RA-DA.COM
WWW.RA-DA.COM
DRAWING NUMBER
2/17/2025 5:22:21 PM
G e n e ra l
A rc h it e c tu ra l In fo rm a ti o n
A001
Q U
E E
N M
A R
Y V
IL
L
A G
E D
E M
O L
IT
IO
N
240322
Q u e e n s
H w y, L o n g B e a ch
C A
B-4853
Issue Date
B
ID
S E
T
.1
.2
0 GENERAL INFORMATION, SITE & EXITING
1 PLANS
2 EXTERIOR ELEVATIONS
3 BUILDING SECTIONS
4 INTERIOR ELEVATIONS
5 DETAILS (INTERIOR, WALL PARTITIONS)
6 FINISHES AND SCHEDULES
A - 1 01
DRAWING SEQUENCE NUMBER
DRAWING TYPE (SEE BELOW)
(DISCIPLINE) SEE BELOW
G GENERAL
C CIVIL
L LANDSCAPE
DM DEMOLITION
S STRUCTURAL
A ARCHITECTURAL
IN INTERIORS
Q EQUIPMENT
F FIRE PROTECTION
P PLUMBING
M MECHANICAL
E ELECTRICAL
T TELECOMMUNICATIONS
SHEET INFORMATION
FIELD VERIFICATION
Before undertaking each part of the Work, the Contractor shall carefully study…