Addendum_6_-_26-012-HG_.pdf
PDF 2 MB Posted
- Attached to
- Leesburg 5th Street Parking Lot Expansion
- Solicitation number
- IFB 26-012-HG
- Issued by
- Lake County, Florida
About this file
This is Addendum No. 6 issued by the City of Leesburg, Florida Procurement Manager Hosea Goodwyn on March 17, 2026, for Invitation for Bid (IFB) No. 26-012-HG for the 5th Street Parking Lot Expansion Project. The addendum makes Attachment F—5th Street Parking Lot Irrigation Drawings dated March 17, 2026—an official part of the solicitation documents. Bidders must acknowledge receipt of this addendum on their Proposal Bid Form, and any bids submitted to the City's Procurement Division will be construed as acknowledgment of the addendum's receipt. The irrigation drawings provided in this addendum detail the complete irrigation system design for the parking lot expansion, including specifications for valve locations, main line sizing (1.5-inch conduit), backflow preventer installation, irrigation controller placement on a concrete pad with 120VAC, 1.0 AMP electrical power supply, rain sensor mounting, and a 1-inch irrigation water meter rated for a minimum of 25 GPM at 60 PSI. The drawings specify that the irrigation contractor must verify all locations in the field before installation, set run times to match plant water requirements and site conditions, follow all local codes, and notify the landscape architect if required water pressure is unavailable on the domestic water line.
The addendum contains technical irrigation design details and does not modify pricing terms, bid bonds, performance requirements, or other contractual provisions established in the original IFB solicitation. All contractors responding to the bid must acknowledge receipt of this addendum as a condition of their bid submission. The drawings are electronically signed and sealed by the consulting firm, GAI Consultants, and are considered official construction documents for the project.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DATE: March 17, 2026 TO: All Interested Bidders and Other Interested Parties FROM: Hosea Goodwyn, Procurement Manager
The City makes the following changes, additions, deletions, information, and/or clarifications and now considers the addendum a part of the IFB Document. Bidders must acknowledge receipt of this addendum by indicating receipt in the space provided on the Proposal Bid Form.
If the bidder has already submitted the Proposal Bid Form to the City’s Procurement Division, the Bidder should revise their electronic submission to include this addendum. In any case, the submission of a bid is an acknowledgment of receipt of the addendum. The City will construe all bids received as though the Bidder has received and acknowledged the addendum.
The attached document is hereby made part of the solicitation.
1. ATTACHMENT F – 5th STREET PARKING LOT IRRIGATION DRAWINGS – 2026-03-17.
IFB 26-012-HG
Leesburg 5th St. Parking Lot Expansion
Addendum No. 6
ACKNOWLEDGMENT - Addendum No. 6
Company Name
Signature of Officer
Type/Print Officer's Name & Title
QV QV
QV
QV QV
QV
QV QV
QV
QV
QV QV
SS SS SS SSSS SS SS SS
M
BF
MVFS
C
LI
RS
24.511 2"
24.511 2"
23.411 2"
41"
21.711 2"
15.41"
22.511 2"
2"
15.41"
1.5" MAIN
1.5" M A
IN
1.5" M
A
IN
1.
5"
M A
IN
1.5" MAIN1.5" MAIN
1.
5"
M A
IN
1.
5"
M A
IN
1.5" M A
IN
BACKFLOW PREVENTER
IRRIGATION INSTALLER TO FOLLOW LOCAL CODES. VERIFY LOCATION IN
THE FIELD BEFORE INSTALLATION. SEE THE PRODUCT LEGEND FOR THE
BACKFLOW MANUFACTURER AND MODEL #.
IRRIGATION CONTROLLER
TO BE PEDESTAL MOUNTED ON A CONCRETE PAD IN THIS AREA. SEE
DETAIL. VERIFY MOUNT LOCATIONS IN THE FIELD PRIOR TO INSTALLATION.
120VAC, 1.0 AMP, ELECTRIC POWER SUPPLY PROVIDED BY THE SITE
ELECTRICAL CONTRACTOR. ROUTE A 1.5" ELECTRICAL CONDUIT WITH
CONTROL WIRES FROM THE CONTROLLER TO THE MAINLINE TRENCH.
MOUNT THE RAIN SENSOR ON A STATIONARY STRUCTURE ABOVE ALL
OVERHEAD OBSTRUCTIONS. PROVIDE TWO (2) ADDITIONAL CONTROL
WIRES IN WIRE BUNDLE FOR FUTURE USE.
THE IRRIGATION CONTRACTOR IS TO SET THE RUN TIMES FOR EACH
ZONE TO MATCH THE PLANT WATER REQUIREMENTS, SITE CONDITIONS
AND MICRO-CLIMATE FACTORS. SEE THE LANDSCAPE PLANS FOR PLANT
SPECIFICATIONS.
IRRIGATION WATER POINT OF CONNECTION
INSTALL A 1" IRRIGATION WATER METER IN THIS AREA. THE WATER METER
IS TO SUPPLY A MINIMUM OF 25GPM AT 60PSI FOR THE EFFICIENT
OPERATION OF THIS SYSTEM. VERIFY LOCATION IN THE FIELD PRIOR TO
INSTALLATION. THE IRRIGATION CONTRACTOR IS TO NOTIFY THE
LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION IF THE REQUIRED
PRESSURE IS NOT AVAILABLE ON THE DOMESTIC WATER LINE.
1257+
*5$3+,&�S&$/(�
)((7
CONSULTANTS
PROJECT
SHEET NUMBER
SHEET TITLE
REVISIONS:
PROJECT NUMBER
REGISTRATION
DRAWN:
CHECKED:
5���������
DATE: ����������
APPROVED:
�7+�S75((7 3$5.,1*�/27
$�*$,�&21S8/7$17S��,1&�S(5V,&(�*5283
����S287+��7+�S75((7 /((S%85*�)/�������
,'S
����(��S287+�S75((7 S8,7(���� 25/$1'2��)/������ &(57,),&$7(�2)�$87+25,=$7,21��(%���� gai consultants
7+,S�,7(0�+$S�%((1�(/(&7521,&$//< S,*1('�$1'�S($/('� 35,17('�&23,(S�2)�7+,S�'2&80(17 $5(�127�&21S,'(5('�S,*1('�$1' S($/('�$1'�7+(�S,*1$785(�08S7�%( V(5,),('�21�$1<�(/(&7521,& &23,(S�
.(,7+�2523(=$��3/$��)/�/,&(1S(���
5HYLVLRQ�� ����������3
,55,*$7,21�3/$1
,5����
,1S7$//�$//�7+(�,55,*$7,21�(Q8,30(17�72�$V2,'�&21)/,&7S�:,7+ ,1S7$//('�87,/,7,(S��75((�,1S7$//$7,21�$1'�(;,S7,1*�75((S�72�5(0$,1�
7+(�,55,*$7,21�0$,1/,1(��/$7(5$/�/,1(��$1'�,55,*$7,21�S35,1./(5 /2&$7,21S�$5(�S+2:1�S&+(0$7,&$//<�$1'�S+$//�%(�$'-8S7('�%$S(' 21�),(/'�&21',7,21S��$//�/$1'S&$3('�$5($S�$5(�72�5(&(,V(�����
&2V(5$*(�%<�7+(�,55,*$7,21�S<S7(0��7<3��
1"
1.5"
2"
2.5" lateral legend
LATERALS LINES ARE COLOR CODED
PER SIZE. FOR THE MOST ACCURATE
INTERPRETATION OF THE DESIGN,
PLANS ARE TO BE VIEWED IN COLOR.
LATERAL/
MAINLINE SIZE
SLEEVE SIZE
1" 2"
1.5" 3"
2" 4"
2.5" 4"
3" 6"
4" 8"
CONTROL WIRE
CONDUIT
2" sleeve legend
Know what's BELOW.
CALL before you dig
Call 811 two business days before digging
IRRI DESIGN STUDIO
IRRIGATION DESIGN & CONSULTING
CONNOR@IRRIDESIGNSTUDIO.COM
407-744-3658
IRRIGATION PLANS ARE TO BE VIEWED IN COLOR FOR
MOST ACCURATE INTERPRETATION OF THE DESIGN.
IRRIGATION EQUIPMENT MAY BE SHOWN OFFSET FOR GRAPHIC
CLARITY. INSTALL ALL EQUIPMENT IN LANDSCAPED AREA.
CONSULTANTS
PROJECT
SHEET NUMBER
SHEET TITLE
REVISIONS:
PROJECT NUMBER
REGISTRATION
DRAWN:
CHECKED:
5���������
DATE: ����������
APPROVED:
�7+�S75((7 3$5.,1*�/27
$�*$,�&21S8/7$17S��,1&�S(5V,&(�*5283
����S287+��7+�S75((7 /((S%85*�)/�������
,'S
����(��S287+�S75((7 S8,7(���� 25/$1'2��)/������ &(57,),&$7(�2)�$87+25,=$7,21��(%���� gai consultants
7+,S�,7(0�+$S�%((1�(/(&7521,&$//< S,*1('�$1'�S($/('� 35,17('�&23,(S�2)�7+,S�'2&80(17 $5(�127�&21S,'(5('�S,*1('�$1' S($/('�$1'�7+(�S,*1$785(�08S7�%( V(5,),('�21�$1<�(/(&7521,& &23,(S�
.(,7+�2523(=$��3/$��)/�/,&(1S(���
5HYLVLRQ�� ����������3
,55,*$7,21�3/$1
,5����IRRI DESIGN STUDIO
IRRIGATION DESIGN & CONSULTING
CONNOR@IRRIDESIGNSTUDIO.COM
407-744-3658
THE QUANTITIES SHOWN IN THE LEGEND SHEETS SHALL NOT BE USED FOR BIDDING
PURPOSES. THE CONTRACTOR WILL BE RESPONSIBLE FOR CONDUCTING A COMPREHENSIVE
MATERIALS TAKEOFF TO DETERMINE THE ACTUAL QUANTITIES OF MATERIAL NECESSARY TO
EXECUTE THE WORK DESCRIBED IN THE DOCUMENTS.
THE IRRIGATION CONTRACTOR IS TO SET THE RUN TIMES FOR EACH ZONE TO MATCH THE
PLANT WATER REQUIREMENTS, SITE CONDITIONS AND MICRO-CLIMATE FACTORS. SEE THE
LANDSCAPE PLANS FOR PLANT SPECIFICATIONS.
irrigation NOTES
1. THE PLANS AND DRAWINGS ARE DIAGRAMMATIC OF THE WORK TO BE PERFORMED.
SOME COMPONENTS MAY BE SHOWN OUTSIDE THE WORK AREA FOR CLARITY. THE
WORK SHALL BE EXECUTED IN A MANNER TO AVOID CONFLICTS WITH UTILITIES AND
OTHER ELEMENTS OF CONSTRUCTION, INCLUDING LANDSCAPE MATERIALS. ALL
DEVIATIONS FROM THE PLANS SHALL BE APPROVED BY THE OWNER'S
REPRESENTATIVE BEFORE BEING INSTALLED.
2. THE IRRIGATION SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE PLANS,
IRRIGATION SYSTEM SPECIFICATIONS AND ALL CONTRACT DOCUMENTS. THE
CONTRACTOR SHALL COMPLY WITH ALL CURRENT LOCAL CODES, ORDINANCES, AND
REGULATIONS.
3. CONTRACTOR SHALL PROVIDE COMPLETE AND ACCURATE IRRIGATION AS-BUILT
DRAWINGS TO THE OWNER AT PROJECT COMPLETION, SHOWING ALL FINAL ROUTING
OF MAINLINES, VALVES, CONTROL WIRE, AND EQUIPMENT LOCATIONS.
4. ALL IRRIGATION MAINLINE AND LATERAL LINES ARE TO NOT EXCEED A VELOCITY OF
5FPS.
5. THE CONTRACTOR SHALL NOT WILLFULLY INSTALL ANY ASPECT OF THE IRRIGATION
SYSTEM AS SHOWN ON THE PLANS AND DRAWINGS, WHEN IT IS OBVIOUS IN THE FIELD
THAT OBSTRUCTIONS, GRADE DIFFERENCES, OR DISCREPANCIES EXIST THAT MIGHT
NOT HAVE BEEN KNOWN DURING THE DESIGN OF THE IRRIGATION SYSTEM. IN THE
EVENT THAT NOTIFICATION OF THE CONFLICT IS NOT APPROVED BY THE OWNER'S
REPRESENTATIVE, THE CONTRACTOR WILL ASSUME FULL RESPONSIBILITY FOR ALL
REVISIONS.
6. REFER TO THE LANDSCAPE PLANS WHEN TRENCHING TO AVOID TREE ROOT BALLS
WHEN INSTALLING IRRIGATION EQUIPMENT. CALL 811 AND REFER TO UTILITY PLANS
PRIOR TO TRENCHING.
7. IRRIGATION CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS, INCLUDING UTILITY
LOCATIONS BEFORE INSTALLATION OF THE IRRIGATION SYSTEM. THE CONTRACTOR IS
RESPONSIBLE FOR COORDINATING INSTALLATION WITH ALL OTHER CONSTRUCTION ON
SITE, ESPECIALLY LANDSCAPE INSTALLATION. THE IRRIGATION SYSTEM SHALL BE
RELOCATED AT NO ADDITIONAL COST FOR ANY CONFLICT WITH LANDSCAPE
INSTALLATION OR ANY OTHER SITE CONSTRUCTION OR EXISTING CONDITIONS.
8. VERIFY THE REQUIRED MINIMUM STATIC WATER PRESSURE IS AVAILABLE AT THE
PROJECT SITE PRIOR TO BEGINNING THE IRRIGATION INSTALLATION. NOTIFY THE
IRRIGATION DESIGN CONSULTANT AND LANDSCAPE ARCHITECT IN WRITING IF THE
MINIMUM STATIC WATER PRESSURE OR WATER VOLUME IS NOT AVAILABLE. SEE PLAN
SHEET FOR REQUIREMENTS.
9. WHERE EXISTING OR NEW TREES, LIGHT FIXTURES, SIGNS, ELECTRONIC CONTROLLERS
AND/OR OTHER OBJECTS ARE AN OBSTRUCTION TO AN IRRIGATION SPRINKLER'S
PATTERN, THE COMPONENT AND PIPING SHALL BE RELOCATED AS NECESSARY TO
OBTAIN PROPER COVERAGE OF AN IRRIGATION SPRINKLER'S PATTERN. THE
COMPONENT AND PIPING SHALL BE RELOCATED AS NECESSARY TO OBTAIN THE
PROPER COVERAGE WITHOUT DAMAGING THE OBSTRUCTION.
10. 100% COVERAGE IS REQUIRED. ASSURE THAT ANY MODIFIED SPACING DOES NOT
EXCEED THE SPACING SHOWN IN THE PLANS.
11. IRRIGATION CONTRACTOR SHALL ADJUST ALL SPRINKLERS TO AVOID OVER SPRAY
ONTO IMPERVIOUS AREAS.
12. ALL MATERIALS AND EQUIPMENT SHOWN SHALL BE NEW AND INSTALLED AS SHOWN
ON THE PLANS. IF THE DRAWINGS DO NOT THOROUGHLY DESCRIBE THE TECHNIQUES
TO BE USED, THE INSTALLER SHALL FOLLOW THE INSTALLATION METHODS AND
INSTRUCTIONS RECOMMENDED BY THE PRODUCT MANUFACTURER.
13. THE LOCATION OF THE IRRIGATION MAINLINE SHALL BE IDENTIFIED IN THE FIELD AND
APPROVED BY THE OWNER'S REPRESENTATIVE BEFORE INSTALLATION.
14. CONTRACTOR IS TO SUBMIT PRODUCT SPECIFICATION SHEETS FOR ALL IRRIGATION
EQUIPMENT TO BE USED FOR APPROVAL BY THE LANDSCAPE ARCHITECT PRIOR TO
INSTALLATION.
15. THE QUANTITIES SHOWN IN THE LEGEND SHEETS SHALL NOT BE USED FOR BIDDING
PURPOSES. THE CONTRACTOR WILL BE RESPONSIBLE FOR CONDUCTING A
COMPREHENSIVE MATERIALS TAKEOFF TO DETERMINE THE ACTUAL QUANTITIES OF
MATERIAL NECESSARY TO EXECUTE THE WORK DESCRIBED IN THE DOCUMENTS.
16. ALL TRENCHES SHALL BE BACKFILLED WITH CLEAN DEBRIS-FREE MATERIALS.
17. IRRIGATION CONTRACTOR IS TO INSTALL CHRISTY ZONE TAGS WITH THE
CORRESPONDING CONTROLLER ZONE NUMBER AT EACH CONTROL VALVE.
18. AS BUILT DOCUMENTS ARE TO BE PROVIDED TO THE OWNER UPON COMPLETION OF
THE PROJECT. THE MAINLINE, CONTROL VALVES, ISOLATION VALVES, GROUND RODS
AND SPLICE BOXES SHALL BE LOCATED WITH A MEASUREMENT FROM TWO FIXED
POINTS.
19. IRRIGATION CONTRACTOR SHALL SECURE ANY AND ALL NECESSARY PERMITS FOR THE
WORK PRIOR TO COMMENCEMENT OF ON-SITE OPERATIONS.
20. A MAINLINE PRESSURE TEST IS TO BE CONDUCTED BEFORE BACKFILLING. ALL
FINDINGS ARE TO BE REPORTED TO THE LANDSCAPE ARCHITECT WITHIN TWENTY
FOUR HOURS POST TEST.
21. ALL SLEEVES ARE TO BE TWO TIMES THE SIZE OF THE PIPE IT ENCASES. INSTALL A 2"
SLEEVE NEXT TO THE MAINLINE SLEEVE FOR CONTROL WIRES.
22. ROUTE A 1.5" ELECTRICAL CONDUIT FROM THE CONTROLLER TO THE MAINLINE TRENCH
FOR THE CONTROL WIRES. RUN THE CONDUIT AND CONTROL WIRES PARALLEL TO THE
MAINLINE.
23. THE IRRIGATION SYSTEM IS TO BE INSPECTED AND APPROVED BY THE PROJECT
OWNER PRIOR TO RECEIVING CERTIFICATION.
24. ANY PRODUCT SUBSTITUTIONS MADE BY THE IRRIGATION CONTRACTOR ARE TO BE
REVIEWED AND APPROVED BY THE OWNER PRIOR TO INSTALLATION.
DRIP SPECIFICATIONS & NOTES:
DRIP TUBING; SPECIFICATION AS SHOWN ON THE PRODUCT SCHEDULE; DRIP GRID LAY-OUT IS
BASED ON 30 PSI.
1. INSTALL DRIP SYSTEM IN THE FOLLOWING ORDER: A). WITH ALL MAINLINE AND IT'S
ASSOCIATE EQUIPMENT (INCLUDING PRE-FILTERING 120 MESH FILTER AT P.O.C.)
COMPLETELY INSTALLED, FLUSH MAINLINE TILL FREE AND CLEAR OF DEBRIS. B). INSTALL ALL
LATERALS TO THE VARIOUS DRIP GRIDS, AND SUPPLY HEADERS WITH RISERS EXTENDED
ABOVE GROUND. CENTER FEED RISERS, TEMPORARY EXTEND NIPPLES WITH PIPE AND
COUPLINGS (DO NOT GLUE). FLUSH TILL FREE AND CLEAR OF DEBRIS, TEMPORARY CAP
NIPPLES, SEAL BLANK TUBING (RISERS) WITH TAPE. C). INSTALL EXHAUST HEADERS - RISERS - FLUSH POINTS. D). INSTALL DRIP GRID, STAPLE TUBING PER DETAIL, CONNECT DRIP TUBING
TO SUPPLY HEADER RISERS. FLUSH TILL FREE AND CLEAR OF DEBRIS. E). CONNECT DRIP
GRID TO EXHAUST HEADER RISERS, FLUSH SYSTEM USING "FLUSH POINT".
2. INSTALL OPERATION INDICATORS WITHIN 12-INCHES OF "FLUSH POINT" VALVE BOX. SEE
DETAIL. ACTIVATE DRIP ZONE, ENSURE ALL OPERATION INDICATORS ARE FULLY EXTENDED,
ADJUST STREAM SPRAY TO WHERE IT CAN EASILY BE SEEN BY MAINTENANCE PERSON.
3. PRESSURE TEST WITH OWNERS REPRESENTATIVE PRESENT; PER ZONE, TEMPORARY INSTALL
(2) PRESSURE GAUGES (LIQUID FILLED PRESSURE GAUGES) ON (2) FLUSH POINTS, (1) ON
LARGEST GRID "FLUSH POINT" AND THE OTHER ON FARTHEST GRID "FLUSH POINT". ACTIVATE
ZONE, AFTER FLOW HAS STABILIZED, VERIFY ALL ZONE OPERATION INDICATORS ARE FULLY
EXTENDED, CHECK PRESSURE ON BOTH GAUGES, PRESSURE MUST BE 20 PSI OR HIGHER TO
PASS TEST. IF TEST FAILS, CONTRACTOR TO LOCATE AND CORRECT PROBLEM AND RETEST.
IT IS IN THE CONTRACTORS BEST INTEREST TO PERFORM HIS OWN TEST BEFORE HE CALLS
OWNERS REPRESENTATIVE PRESENTS TO AVOID RE-INSPECTION FEE'S.
4. PRESSURE TEST RESULTS SHALL BE NOTED AS-BUILD DRAWING BY THE "FLUSH POINT"
WHERE TESTS WAS TAKEN. ALL "FLUSH POINTS" LOCATIONS SHALL BE INCLUDED IN AS-BUILD
DRAWINGS.
THE FOLLOWING PRODUCTS ARE NOT SHOWN ON THE PLAN FOR GRAPHIC CLARITY BUT ARE
TO BE INCLUDED DURING THE BIDDING PROCESS AND ARE TO BE INSTALLED BY THE
IRRIGATION INSTALLATION CONTRACTOR. FOLLOW ALL MANUFACTURERS SPECIFICATIONS
AND RECOMMENDATIONS.
- FLUSH VALVES (MANUAL OR AUTOMATIC).
- AIR RELIEF VALVES - LOCATE AT THE HIGHPOINT OF THE ZONE.
- DRIP INDICATOR HEAD - LOCATE IN AN INCONSPICUOUS AREA BUT ACCESSIBLE BY THE SITE
MAINTENANCE TEAM.
1"
1.5"
2"
2.5" lateral legend
LATERALS LINES ARE COLOR CODED
PER SIZE. FOR THE MOST ACCURATE
INTERPRETATION OF THE DESIGN,
PLANS ARE TO BE VIEWED IN COLOR.
LATERAL/
MAINLINE SIZE
SLEEVE SIZE
1" 2"
1.5" 3"
2" 4"
2.5" 4"
3" 6"
4" 8"
CONTROL WIRE
CONDUIT
2" sleeve legend
IRRIGATION PLANS ARE TO BE VIEWED IN COLOR FOR
MOST ACCURATE INTERPRETATION OF THE DESIGN.
IRRIGATION EQUIPMENT MAY BE SHOWN OFFSET FOR GRAPHIC
CLARITY. INSTALL ALL EQUIPMENT IN LANDSCAPED AREA.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI
RAIN BIRD 1800-1400 FLOOD
FIXED FLOW RATE 0.25 GPM - 2.0 GPM, FULL CIRCLE BUBBLER,
1/2IN. FIPT.
28 30
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI
RAIN BIRD XCZ-100-LC
WIDE FLOW DRIP CONTROL KIT, FOR LIGHT COMMERCIAL
USES. 1IN. PEB VALVE, WITH 1IN. PRESSURE REGULATING
40PSI BASKET FILTER. 0.3-20 GPM.
RAIN BIRD XCZ-150-LCS
HIGH FLOW CONTROL ZONE KIT, FOR LARGE COMMERCIAL
DRIP ZONES. 1-1/2IN. PEB GLOBE VALVE WITH SINGLE 1-1/2IN.
PRESSURE REGULATING 40PSI QUICK-CHECK BASKET FILTER.
FLOW RANGE: 15-62 GPM.
AREA TO RECEIVE DRIPLINE
RAIN BIRD XFS-09-12 (GROUND LEVEL)
XFS SUB-SURFACE PRESSURE COMPENSATING DRIPLINE
W/COPPER SHIELD TECHNOLOGY. 0.9 GPH EMITTERS AT 12"
O.C. LATERALS SPACED AT 12" APART, WITH EMITTERS
OFFSET FOR TRIANGULAR PATTERN. UV RESISTANT. SPECIFY
XF INSERT FITTINGS.
9,823 LF 10
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
RAIN BIRD PEB
1IN., 1-1/2IN., 2IN. PLASTIC INDUSTRIAL VALVES. LOW FLOW
OPERATING CAPABILITY, GLOBE CONFIGURATION.
LANDSCAPE PRODUCTS INC. BBV
1/2IN., 3/4IN., 1IN., 1-1/4IN., 1-1/2IN., 2IN., 2-1/2IN., 3IN. FULL
PORT BRASS BALL VALVE. SUITABLE FOR A FULL RANGE OF
LIQUIDS AND GASES IN RESIDENTIAL AND COMMERCIAL
APPLICATIONS.
RAIN BIRD PEB-PRS-D (MASTER VALVE) 1"
1IN., 1-1/2IN., 2IN. PLASTIC INDUSTRIAL MASTER VALVES. LOW
FLOW OPERATING CAPABILITY, GLOBE CONFIGURATION. WITH
PRESSURE REGULATOR MODULE.
ZURN 975XL 1"
REDUCED PRESSURE BACKFLOW DEVICE
RAIN BIRD ESPLXME2-LXMM-LXMMPED W/ (1) ESPLXMSM12 (3)
24 STATION, TRADITIONALLY-WIRED, COMMERCIAL
CONTROLLER.(1) ESPLXME2 12-STATION, INDOOR/OUTDOOR,
PLASTIC WALL-MOUNT ENCLOSURE W/ (1) ESPLXMSM12 -
12-STATION EXPANSION MODULE. INSTALL IN LXMM-LXMMPED
POWDER COATED, METAL WALL-MOUNTED CABINET W/
PEDESTAL
RAIN BIRD LNK2WIFI
UPGRADES CONTROLLERS (ESP-M, ESP-RZXE, ST8) TO HAVE
WEATHER DATA FOR ET-BASED ADJUSTMENTS (WATERSENSE
APPROVED) & WIFI CAPABILITIES -
RAIN BIRD WR2-RC
WIRELESS RAIN SENSOR COMBO, INCLUDES 1 RECEIVER AND
1 RAIN SENSOR TRANSMITTER.
RAIN BIRD UFS-100
1IN. ULTRASONIC FLOW SENSORS, WITH GLASS FILLED NYLON
BODY. OPERATING RANGE .3 GPM-50 GPM. SIZE FOR FLOW
NOT ACCORDING TO PIPE SIZE.
POINT OF CONNECTION
1" RECORDALL BADGER DISC METER OR EQUAL PROVIDED BY
OTHERS
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21
SEE PIPE LEGEND FOR COLOR CODING AND SIZING.
2,602 LF
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 811.5 LF
PIPE SLEEVE: PVC SCHEDULE 40
MAINLINE & LATERAL LINE SLEEVE.
777.0 LF
PIPE SLEEVE: PVC SCHEDULE 40
2" SLEEVE FOR WIRE CONDUIT.
220.7 LF
1408140414021401
MV
BF
C
LI
RS
FS
M
Valve Number
Valve Flow
Valve Size
Valve Callout
IRRIGATION SCHEDULE
NUMBER MODEL SIZE TYPE GPM PRECIP
1 RAIN BIRD XCZ-150-LCS 1-1/2" AREA FOR DRIPLINE 24.48 1.44 in/h 2 RAIN BIRD XCZ-150-LCS 1-1/2" AREA FOR DRIPLINE 24.54 1.45 in/h 3 RAIN BIRD XCZ-150-LCS 1-1/2" AREA FOR DRIPLINE 23.4 1.44 in/h 4 RAIN BIRD PEB 1" BUBBLER 4 1.7 in/h 5 RAIN BIRD XCZ-150-LCS 1-1/2" AREA FOR DRIPLINE 21.66 1.44 in/h 6 RAIN BIRD XCZ-100-LC 1" AREA FOR DRIPLINE 15.39 1.44 in/h 7 RAIN BIRD XCZ-150-LCS 1-1/2" AREA FOR DRIPLINE 22.46 1.45 in/h 8 RAIN BIRD PEB 1-1/2" BUBBLER 10 1.9 in/h 9 RAIN BIRD XCZ-100-LC 1" AREA FOR DRIPLINE 15.42 1.44 in/h
VALVE SCHEDULE
CRITICAL ANALYSIS
P.O.C. NUMBER: 01
Water Source Information: 1" RECORDALL BADGER DISC METER OR
EQUAL PROVIDED BY OTHERS.
FLOW AVAILABLE
Custom Max Flow: 25 GPM Flow Available 25 GPM
PRESSURE AVAILABLE
Static Pressure at POC: 60 PSI Pressure Available: 60 PSI
DESIGN ANALYSIS
Maximum Multi-valve Flow: 25 GPM Flow Available at POC: 25 GPM Residual Flow Available: 0 GPM
Critical Station: 8 Design Pressure: 30 PSI Friction Loss: 1.29 PSI Fittings Loss: 0.13 PSI Elevation Loss: 0 PSI Loss through Valve: 3.9 PSI Pressure Req. at Critical Station: 35.3 PSI Loss for Fittings: 0.13 PSI Loss for Main Line: 1.29 PSI Loss for POC to Valve Elevation: 0 PSI Loss for Backflow: 12.1 PSI Loss for Master Valve: 4.25 PSI Critical Station Pressure at POC: 53.0 PSI Pressure Available: 60 PSI Residual Pressure Available: 6.96 PSI
SHEET NUMBER
SHEET TITLE
REVISIONS:
PROJECT NUMBER
REGISTRATION
DRAWN:
CHECKED:
5���������
DATE: ����������
APPROVED:
�7+�S75((7 3$5.,1*�/27
$�*$,�&21S8/7$17S��,1&�S(5V,&(�*5283
����S287+��7+�S75((7 /((S%85*�)/�������
,'S
����(��S287+�S75((7 S8,7(���� 25/$1'2��)/������ &(57,),&$7(�2)�$87+25,=$7,21��(%���� gai consultants
7+,S�,7(0�+$S�%((1�(/(&7521,&$//< S,*1('�$1'�S($/('� 35,17('�&23,(S�2)�7+,S�'2&80(17 $5(�127�&21S,'(5('�S,*1('�$1' S($/('�$1'�7+(�S,*1$785(�08S7�%( V(5,),('�21�$1<�(/(&7521,& &23,(S�
.(,7+�2523(=$��3/$��)/�/,&(1S(���
5HYLVLRQ�� ����������3
,55,*$7,21�'(7$,/S
,5����IRRI DESIGN STUDIO
IRRIGATION DESIGN & CONSULTING
CONNOR@IRRIDESIGNSTUDIO.COM
407-744-3658
N.T.S.
NOTES:
1. ALL ASSEMBLY PARTS (THREADED NIPPLES, FITTINGS, ETC.) SHALL BE GALVANIZED OR BRASS PER LOCAL
CODES AND REQUIREMENTS.
2. GALVANIZED NIPPLE SHALL EXTEND 12" PAST THE EDGE OF THE CONCRETE FOOTING.
3. SCH. 80 PVC MALE ADAPTER SHALL BE USED IN CONNECTION FROM GALVANIZE TO THE MAINLINE.
4. BACKFLOW PREVENTION DEVICE SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE LANDSCAPE METER.
5. BACKFLOW PREVENTION DEVICE SHALL BE LOCATED IN PLANTING AREA UNLESS APPROVED BY
OWNER'S REPRESENTATIVE.
6. ALL BACKFLOW PREVENTION DEVICES SHALL HAVE FREEZE BLANKET INCLUDED UPON INSTALLATION.
7. ALL GALVANIZED CONNECTIONS SHALL TO BE MADE USING PIPE THREAD SEALANT. ALL SCH. 80 PVC TO
GALVANIZED CONNECTIONS TO BE MADE USING TEFLON TAPE.
FLOW
DIRECTION
BACKFLOW PREVENTION
DEVICE (SEE IRRIGATION
PLANS FOR MAKE AND
MODEL). INSTALL DEVICE
PER THE LOCAL WATER
PURVEYOR'S STANDARDS
AND SPECIFICATIONS
GALVANIZED NIPPLE2
4" THICK CONCRETE PAD, 1"
ABOVE FINISHED GRADE.
SEE BACKFLOW CAGE DETAIL
CONCRETE THRUST BLOCKS
REQUIRED ON BACKFLOW
DEVICES 2-1/2" AND LARGER
BRASS BALL VALVE5
THREADED GALVANIZED
NIPPLE
GALVANIZED 90° (DEGREE)
ELBOW
GALVANIZED UNION8
WRAP 20 MIL TAPE TWICE
AROUND GALVANIZED PIPE
UNDER FINISHED GRADE AND
THROUGH THE CONCRETE
GALVANIZED COUPLING10
SCH. 80 PVC MALE ADAPTER11
" M
IN
O
R P
E R
L O
C A
L C
O D
E S
BACKFLOW PREVENTION DEVICE
I-RBD-01
N.T.S.
GROUNDING ROD
8'-0" TO 12'-0"
NOTES:
1. ALL GROUNDING REQUIREMENTS FOR CONTROLLERS
SHALL CONFORM TO LOCAL ELECTRIC CODES.
2. GROUNDING ROD SHALL NOT BE LOCATED IN THE SAME
TRENCH AS IRRIGATION MAINLINES OR LATERAL LINES.
3. VALVE BOX SHALL BE WRAPPED WITH A MINIMUM 3 MIL
THICK PLASTIC AND SECURED TO THE VALVE BOX
USING DUCT TAPE OR ELECTRICAL TAPE.
4. INSTALL GROUNDING ROD PER THE CONTROLLER
MANUFACTURER'S SPECIFICATIONS AND
RECOMMENDATIONS.
1 2
" M
IN
IM
U M
W
IR
E D
E P
TH
FINISH GRADE1
PAVEMENT2
THREE (3) 4" x 8" BRICKS3
5/8" x 8'-0" COPPER GROUNDING
ROD
GROUNDING ROD CLAMP5
#6 AWG BARE COPPER WIRE6
1/2" PVC ELECTRICAL CONDUIT AND
SWEEP FOR EARTH GROUND
COPPER GROUNDING PLATE8
I-RBD-03
N.T.S.
PEDESTAL MOUNTED CONTROLLER
4"
3"
PEDESTAL MOUNT IRRIGATION
CONTROLLER ON CONCRETE FOOTING.
USE GALVANIZED 'J' BOLTS TO SECURE
THE CONTROLLER TO THE PAD
GFI RECEPTACLE AND LOCKING
SWITCH
1" SCH. 40 CONDUIT WITH SWEEP ELL
FOR 120 VOLT SOURCE
CONCRETE BASE: 6" MIN. THICKNESS,
EXTEND 6" BEYOND OUTSIDE
DIMENSIONS OF ENCLOSURE WITH
SLOPE FOR DRAINAGE
18 GA. WIRE HARNESS TO
CONTROLLER
TERMINAL STRIPS, ARCHER BRAND
#274-679, OR APPROVED EQUAL, SIZE
AS REQUIRED
14 GA. WIRES FROM FIELD7
1-1/2" PVC SCH. 40 CONDUIT WITH
LONG SWEEP ELL
I-RBD-06
N.T.S.
STATIONARY STRUCTURE1
2 RAIN BIRD WR2 SERIES (WEATHER STATION)
NOTES:
1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATIONS.
2. SENSOR MAY BE MOUNTED ON A FENCE, FENCE POST, GUTTER
OR BUILDING.
3. SENSOR SHOULD NOT BE MOUNTED UNDER TREES, IN AREAS
AFFECTED BY SPRINKLER SYSTEM OR UNDER EAVE OF BUILDING.
RAIN BIRD - WR2 SERIES WEATHER STATION
RED
OR
BLACK
WIRES
TO
HERE
GREEN
OR
WHITE
WIRES
TO
HERE
G N
D
V
A C
S E
N
C O
M
WIRING DETAIL
I-RBD-10
N.T.S.
IRRIGATION TRENCHING
127(S�
�� S((�,55,*$7,21�/(*(1'�)25�0$,1/,1(�$1'�/$7(5$/ /,1(�3,3(�S,=(�$1'�7<3(�
�� ',5(&7�%85,$/�&21752/�:,5(S�S+$//�%(�,1S7$//(' ,1�S&+�����3V&�(/(&75,&$/�&21'8,7�,)�5(Q8,5('�
�� ��:,5(�,55,*$7,21�:,5(�S+$//�%(�,1S7$//('�,1�S&+� ���3V&�(/(&75,&$/�&21'8,7�
�� '(7(&7$%/(�/2&$725�7$3(�S+$//�%(�/2&$7('�S,;
,1&+(S������$%2V(�7+(�(17,5(�0$,1/,1(�581�
24" MIN.
6"
1' -0
" I N
P
LA
N
TI
N G
A R
E A
FINISHED GRADE1
PAVEMENT2
NON-PRESSURIZED LINE
(LATERAL LINE)
DETECTABLE LOCATOR TAPE4
PRESSURIZED LINE (MAINLINE)5
DIRECT BURIAL LOW VOLTAGE
CONTROL WIRES
�3
7, �8 (5
7+ �3 $V
(0 (1
I-RBD-12
N.T.S.
NOTES:
1. SEE IRRIGATION LEGEND FOR MAINLINE SIZE AND TYPE.
2. ALL SLEEVES SHALL BE SCH. 40 PVC PIPE.
3. ALL SLEEVES SHALL EXTEND 12" BEYOND THE EDGE OF PAVEMENT.
4. END OF SLEEVES SHALL BE LOCATED WITH A WOODEN STAKE OR PVC
PIPE. LOCATORS SHALL RUN CONTINUOUSLY FROM THE END OF THE
SLEEVE TO FINISHED GRADE.
PIPE BENEATH PAVEMENT
3' -0
PAVEMENT1
BASE ROCK2
CLEAN BACKFILL, 95%
RELATIVE COMPACTION
UNDER PAVING OR PER
CIVIL ENGINEER'S PLANS
CONTROL WIRES, SLEEVE
UNDER PAVING.
INSTALL ADJACENT TO
PRESSURIZED MAINLINE.
BUNDLE SHALL BE NO
MORE THAN 50% OF PIPE
DIAMETER
MAINLINE, SLEEVE UNDER
PAVING TO BE TWO
TIMES THE DIAMETER
OF THE PRESSURIZED
MAINLINE PIPE
NON-PRESSURIZED LINE,
SLEEVE UNDER PAVING
TO BE BE TWO TIMES
THE DIAMETER OF THE
LATERAL LINE
I-RBD-14
N.T.S.
MAINLINE WITH SAND BEDDING
4" M
IN
4"
MIN.
4"
MIN.
4" M
IN
D E
P
TH
A S
P E
R S
P E
C
IF
IC
A
TI
O
N
1 WIDTH VARIES
BEDDING
FINISHED GRADE1
NATIVE SOIL BACKFILL
COMPACT TO 95%
COMPACTION
PVC MAINLINE/LATERAL3
BACKFILL WITH 100% COARSE
SAND, WATER JET AND
MECHANICALLY COMPACT
TO 90% OPTIMUM DENSITY.
ALLOW 48 HOURS TO SETTLE,
AND BACKFILL AND COMPACT
WITH NATIVE SOIL
I-RBD-16
N.T.S.
SLEEVE AT ROAD
4" M
IN
4"
MIN.
4"
MIN.
4" M
IN
D E
P
TH
A S
P E
R S
P E
C
IF
IC
A
TI
O
N
WIDTH VARIES
BEDDING
FINISHED GRADE1
NATIVE SOIL BACKFILL
COMPACT TO 95%
COMPACTION
PVC SLEEVE3
BACKFILL WITH 100% COARSE
SAND, WATER JET AND
MECHANICALLY COMPACT
TO 90% OPTIMUM DENSITY.
ALLOW 48 HOURS TO SETTLE,
AND BACKFILL AND COMPACT
WITH NATIVE SOIL
I-RBD-17
N.T.S.
RAIN BIRD MASTER VALVE & UFS (FLOW SENSOR)
MODEL SIZE K OFFSET FLOW RANGE
UFS100 1" 0.25 0 0.3 - 50 GPM
UFS150 1.5" 1.70 -0.316 0.5 - 110 GPM
UFS200 2" 2.849 0.1439 1.0 - 200 GPM
NOTES:
1. THE UFS CAN BE INSTALLED IN A VERTICAL POSITION WITH THE
FLOW ARROW POINTING UPWARDS.
2. THE UFS SIZE MUST BE EQUAL TO OR SMALLER THAN THE
INCOMING PIPE SIZE.
3. THE UFS DOES NOT REQUIRE STRAIGHT PIPE BEFORE OR AFTER
SENSOR PLACEMENT.
4. NO BRICKS REQUIRED FOR RAIN BIRD VB-SERIES VALVE BOXES
ONLY.
1 RAIN BIRD MASTER VALVE (PER SCHEDULE)
RAIN BIRD UFS SERIES FLOW SENSOR2
3 CONTROL WIRE WITH WATERPROOF SPLICE
CONNECTION
3" MINIMUM DEPTH OF 3 4" WASHED GRAVEL4
BRICK (1 OF 4)5
6 JUMBO VALVE BOX WITH COVER
FINISH GRADE7
8 PVC MAINLINE
PVC MALE ADAPTER9
10 PVC CLOSE NIPPLE (1 OF 3)
PVC UNION (1 OF 2)11
8" WELDED WIRE MESH12
FLOW
1112104
I-RBD-19
9 BRASS BALL ISOLATION VALVE
N.T.S.
FINISH GRADE1
2 RECTANGULAR VALVE BOX
BRASS BALL VALVE AS SPECIFIED,
SAME SIZE AS MAIN LINE
4 SCHEDULE 80 THREADED NIPPLE
AS REQUIRED
PVC MAINLINE5
3/4" MINUS WASHED GRAVEL6
WIRE FABRIC CLOTH7
8 BRICK (1 OF 4)
6 7 8
I-RBD-23
SHEET NUMBER
SHEET TITLE
REVISIONS:
PROJECT NUMBER
REGISTRATION
DRAWN:
CHECKED:
5���������
DATE: ����������
APPROVED:
�7+�S75((7 3$5.,1*�/27
$�*$,�&21S8/7$17S��,1&�S(5V,&(�*5283
����S287+��7+�S75((7 /((S%85*�)/�������
,'S
����(��S287+�S75((7 S8,7(���� 25/$1'2��)/������ &(57,),&$7(�2)�$87+25,=$7,21��(%���� gai consultants
7+,S�,7(0�+$S�%((1�(/(&7521,&$//< S,*1('�$1'�S($/('� 35,17('�&23,(S�2)�7+,S�'2&80(17 $5(�127�&21S,'(5('�S,*1('�$1' S($/('�$1'�7+(�S,*1$785(�08S7�%( V(5,),('�21�$1<�(/(&7521,& &23,(S�
.(,7+�2523(=$��3/$��)/�/,&(1S(���
5HYLVLRQ�� ����������3
,55,*$7,21�'(7$,/S
,5����IRRI DESIGN STUDIO
IRRIGATION DESIGN & CONSULTING
CONNOR@IRRIDESIGNSTUDIO.COM
407-744-3658
N.T.S.
1.5" RAIN BIRD DRIP CONTROL ZONE KIT
NOTE:
1. THE KIT INCLUDES A VALVE AND SCREEN FILTER.
RAIN BIRD DRIP KIT (PER SCHEDULE)1
2 WATERPROOF SPLICE CONNECTION
VALVE BOX WITH COVER: RAIN BIRD
VB-JUMBO
5 FINISH GRADE
PVC LATERAL PIPE6
BRICK (1 OF 4)7
3/4" MINUS WASHED GRAVEL8
9 WIRE FABRIC CLOTH
PVC MAINLINE10
11 PVC SCH 80 ELBOW
PVC SCH 80 NIPPLE 1-1/2"12
13 PVC SCH 80 NIPPLE AND PVC
SCH 80 ELBOW
PVC SCH 80 TEE OR ELBOW14
VALVE ID TAG3
1 2 4 53
I-RBD-26
N.T.S.
RAIN BIRD REMOTE CONTROL VALVE
RAIN BIRD REMOTE CONTROL VALVE
(PER SCHEDULE)
2 WATERPROOF SPLICE CONNECTION
VALVE BOX WITH COVER: RAIN BIRD4
5 FINISH GRADE
PVC LATERAL PIPE6
BRICK (1 OF 4)7
3/4" MINUS WASHED GRAVEL8
9 WIRE FABRIC CLOTH
PVC MAINLINE10
11 PVC SCH 80 ELBOW
PVC SCH 80 NIPPLE 1-1/2"12
13 PVC SCH 80 NIPPLE AND PVC
SCH 80 ELBOW
PVC SCH 80 TEE OR ELBOW14
1 2 4 5
VALVE ID TAG3
I-RBD-29
PLAN VIEW
SECTION VIEW
IRRIGATION BUBBLER W/ LAYOUT
N.T.S.
NOTES:
1. ALL IRRIGATION FITTINGS SHALL BE SCH. 40 PVC UNLESS
SPECIFIED OTHERWISE.
2. ALL THREADED CONNECTIONS FROM SCH. 40 TO SCH. 80 PVC
SHALL BE MADE USING TEFLON TAPE.
3. CONTRACTOR SHALL SETTLE THE AREA AROUND THE
BUBBLER AND EDGE OF THE ROOT BALL SO THAT ALL
IRRIGATION FLOWS THROUGH THE ROOT BALL.
FINISHED GRADE1
PRESSURE COMPENSATING BUBBLER SHALL BE SET 1"
ABOVE FINISHED GRADE (SEE IRRIGATION SCHEDULE FOR
MAKE AND MODEL)
SWING JOINT, SEE DETAIL3
SCH. 40 PVC 90° ELBOW SLIP TO THREAD4
LATERAL LINE IRRIGATION (SEE IRRIGATION PLANS FOR
SIZING)
EDGE OF ROOT BALL. SETTLE BACKFILL SO IRRIGATION
FLOWS THROUGH ROOT BALL
EDGE OF ROOT BALL7
EXISTING OR MODIFIED SOIL (SEE SPECIFICATIONS FOR
SOIL MODIFICATION)
SCH. 40 PVC TEE OR 90° ELBOW9
" M
IN
M
U M
I-RBD-35
PLAN VIEW
SECTION VIEW
NOTES:
1. ALL IRRIGATION FITTINGS SHALL BE SCH. 40 PVC UNLESS
SPECIFIED OTHERWISE.
2. ALL THREADED CONNECTIONS FROM SCH. 40 TO SCH. 80 PVC
SHALL BE MADE USING TEFLON TAPE.
3. CONTRACTOR SHALL SETTLE THE AREA AROUND THE
BUBBLER AND EDGE OF THE ROOT BALL SO THAT ALL
IRRIGATION FLOWS THROUGH THE ROOT BALL.
IRRIGATION BUBBLER (2) W/ LAYOUT
N.T.S.
FINISHED GRADE1
PRESSURE COMPENSATING BUBBLER SHALL BE SET 1" ABOVE
FINISHED GRADE (SEE IRRIGATION SCHEDULE
FOR MAKE AND MODEL)
SWING JOINT, SEE DETAIL3
SCH. 40 PVC 90° ELBOW SLIP TO THREAD4
LATERAL LINE IRRIGATION (SEE IRRIGATION
PLANS FOR SIZING)
EDGE OF ROOT BALL. SETTLE BACKFILL SO
IRRIGATION FLOWS THROUGH ROOT BALL
EDGE OF ROOT BALL7
EXISTING OR MODIFIED SOIL (SEE SPECIFICATIONS
FOR SOIL MODIFICATION)
SCH. 40 PVC TEE OR 90° ELBOW9
1 2
" M
IN
M
U M
I-RBD-36
PVC MAINLINE.
PIPE.
1" PVC LATERAL
TYPICAL
COMPRESSION
FITTING.
AIR RELIEF VALVE AT
HIGH POINT, AS
INDICATED.
&(17(5�)(('�(;$03/(
EMITTER 12" 18" 24"
FLOW SPACING SPACING SPACING
0.6 GPH 1.0 GPM 0.67 GPM 0.50 GPM
0.9 GPH 1.5 GPM 1.0 GPM 0.75 GPM
/$7(5$/�)/2:�3(5�����)7��*30�
(1'�)(('�(;$03/(
FLUSH VALVE OR CAP
AT LOW END, AS NOTED.
TYPICAL DRIP LINE WITH
EMITTER SPACING AS
NOTED. TIE DOWN
STAKE AT ALL TEES,
ELLS, AND AT 4' O.C. AT
CLAY, 3' O.C. AT LOAM,
OR 2' O.C. AT SAND.
EMITTER FLOW RATE
EMITTER LATERAL
SPACING SPACING 0.6 0.9
12 12 0.96 1.44 18 18 0.69 1.03 24 24 0.28 0.41
*5,'�35(&,3,7$7,21�5$7(S��,1�+5�
MAX GPM PSI LOSS
SCHEDULE 40 PVC HEADER SIZE
1/2" 4.7 GPM 7.7 PSI
3/4" 8.3 GPM 5.6 PSI
1" 13.5 GPM 4.2 PSI
1-1/2" 33.9 GPM 2.9 PSI
2" 52.4 GPM 1.9 PSI
POLY PIPE HEADER SIZE
1/2" 4.7 GPM 8.8 PSI
3/4" 8.3 GPM 6.3 PSI
1" 13.5 GPM 4.8 PSI
1-1/2" 31.8 GPM 2.9 PSI
2" 52.4 GPM 2.2 PSI
0$;,080�)/2:�3(5�=21(
EMITTER FLOW RATE GPH
12" SPACING 18" SPACING 24" SPACING
PSI 0.6 0.9 0.6 0.9 0.6 0.9
10 125 96 175 135 218 171 20 249 191 350 171 442 340 30 307 236 434 333 550 422 40 350 268 495 380 627 171 50 125 96 175 135 218 171 60 125 96 175 135 218 171
0$;,080�/$7(5$/�/(1*7+��)((7�
TYPICAL FPT ADAPTER AND
COMPRESSION COUPLER.
DRIP VALVE / FILTER /
REGULATOR.
TYPICAL OFFSET 2"
FROM
HARDSCAPE, 4"
FROM PLANTED
AREA.
'2*%21(�S+$3(' &251(5�S+$3(' &85V('�32/<*21 +285*/$SS�S+$3('
32/<*21�S+$3(' �&��S+$3(' 2''�S+$3('
PVC MANIFOLD LINE.
LANDSCAPE
DRIPLINE TUBING.
LANDSCAPE DRIPLINE TUBING.
PVC MANIFOLD LINE
WITH PVC TEE.
WATER SOURCE: DRIP VALVE
OR LATERAL FROM VALVE.
FLUSH CAP
AIR RELIEF VALVE:
AR VALVE KIT, INSTALL AT
HIGH POINT OF SYSTEM.
TYPICAL DRIPLINE REQUIREMENTS
N.T.S.
TYPICAL OFFSET 2" FROM
HARDSCAPE, 4" FROM
PLANTED AREA.
PVC SCH 40 TEE OR ELL.
EASY FIT COMPRESSION
ADAPTER.
EASY FIT COMPRESSION
COUPLING.
DRIPLINE SPACING AS
NOTED. EMITTERS
OFFSET FOR
TRIANGULAR SPACING.
POLYETHYLENE OR PVC HEADER
MANIFOLD, SIZE AS PER "MAXIMUM
FLOW PER ZONE" CHART.
M A
X
IM
U M
L E
N G
TH
O
F S
IN
G
LE
LA
TE
R A
L, S
E E
C H
A R
T.
M A
X
IM
U M
L E
N G
TH
O
F S
IN
G
LE
LA
TE
R
A L, S E
E C
H A
R T.
SLOPED CONDITION NOTE:
1. DRIPLINE LATERALS SHOULD FOLLOW THE CONTOURS OF THE SLOPE.
2. INSTALL AIR RELIEF VALVE AT HIGHEST POINT.
3. NORMAL SPACING WITHIN THE TOP 23 OF SLOPE.
4. INSTALL DRIPLINE AT 25% GREATER SPACING AT THE BOTTOM 13 OF THE
SLOPE.
5. WHEN THE ELEVATION CHANGE IS 10FT OR MORE, ZONE THE BOTTOM 13
ON A SEPARATE VALVE.
I-RBD-38
File details come from the government source that posted it. Updated .