Addendum #4 - Drawings.pdf
PDF 10 MB Posted
- Solicitation number
- BPM057381
- Issued by
- Maryland
About this file
This is Addendum #4 to the 100% Construction Documents for the Barrack J Communication Room & Garage project located at 610 Taylor Avenue, Annapolis, Maryland 21401. The addendum consists of architectural, plumbing, and electrical drawings that provide detailed construction specifications for renovation and new construction work on two buildings: an existing barracks facility and a new garage structure. The project includes comprehensive plans for code compliance, occupancy analysis, ADA accessibility, site logistics, equipment and finish schedules, building elevations, door and window details, and complete mechanical, plumbing, and electrical systems. Key spaces in the garage include vehicle maintenance and service bays, vehicle evidence bay, vehicle wash bay, toilet facilities, storage areas for parts, tires, and flammable materials, radio communications and workshop areas, K-9 wash facilities, and various office spaces. The documents are dated 03/05/2026 with addendum notation dated 08/07/2026 and are prepared by Manns Woodward Studios, Inc., a Maryland-licensed architectural firm, with project number PJ-610-230-001 and design consultant MWS.
The construction documents include detailed specifications for building systems, materials, and equipment, with equipment schedules identifying items such as vehicle lifts (Rotary Lift models), tire racks, security lockers (Fasco Security Products), and wire shelving. Finish materials are specified with particular attention to high-performance coatings, resinous flooring systems, sealed concrete, and static dissipative tiles in designated areas. Electrical systems include multiple panelboards, GFCI receptacles, fire alarm systems, lighting controls with occupancy sensors, emergency systems, and dedicated circuits for specialized equipment. Plumbing systems feature domestic hot water heating with recirculation, trench drains in vehicle service areas, compressed air systems with duplex air compressors rated at 18 CFM at 175 PSI, and fire protection systems including pre-action sprinkler coverage. Door hardware specifications include electrified strikes, card reader access control systems, and panic bars coordinated with a building-wide access control system. Site logistics notes indicate that the contractor must maintain owner access and parking, coordinate work with minimum 72-hour advance notice, and preserve existing site operations throughout construction.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FE
PER OCC
B
363 SF GROSS
3 OCCUPANTS
OFFICE
150 SF
BUSINESS
PER OCC
S-1
3,145 SF GROSS
11 OCCUPANTS
GARAGE & STORAGE ROOMS
300 SF
STORAGE
PER OCC
B
200 SF GROSS
2 OCCUPANTS
OFFICES
150 SF
BUSINESS
EXIT
EXIT
EXIT
EXIT
EXIT
CP-2
COMMON
PATH
CP-3
COMMON
PATH
DE-1
DEAD
ENDDE-2
DEAD
END
34"
36"
34"
36"
34"
36"
34"
36"
VEHICLE
WASH BAY
RADIO
COMMUNICATIONS
RADIO
WORKSHOP
FMD
GROUNDS
STORAGE
K-9 WASH
108 FMD OFFICE
MECHANIC'S
OFFICE
PARTS &
TOOLS
TIRE
STORAGE
FLAMMABLE
OIL
STORAGE
MECH/ELEC/AIR
COMPRESSOR
TOILET
VEHICLE
MAINT /
SERVICE
BAYS
VEHICLE
EVIDENCE
BAY
PER OCC
S-1
492 SF GROSS
2 OCCUPANTS
VEHICLE WASH BAY
300 SF
STORAGE
PER OCC
S-1
141 SF GROSS
1 OCCUPANTS
VEHICLE WASH BAY
300 SF
STORAGE
EXIT SEPARATION DISTANCE
44'-6"
CP-1
COMMON
PATH
B OCCUPANCY (BUSINESS OCCUPANT LOAD)
S-1 OCCUPANCY (STORAGE OCCUPANT LOAD)
TRAVEL DISTANCE
PATH OF TRAVEL
RW
AW
OL
OL = OCCUPANT LOAD
RW = REQUIRED EGRESS WIDTH
AW = ACTUAL EGRESS WIDTH
FIRE EXTINGUISHER
ILLUMINATED EXIT SIGN
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
PROJECT No.:
DATE:
SHEET _____ OF _____
SEAL:
DRAWING TITLE:
SHEET NUMBER:BUILDING NUMBER:
B2
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
8098 SANDPIPER CIRCLE, SUITE H
NOTTINGHAM, MD 21236
ARCHITECTURE + MASTER PLANNING
B1
B2
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED
OR APPROVED BY ME, AND THAT I AM A DULY LICENSED
PROFESSIONAL ARCHITECT UNDER THE LAWS OF THE STATE OF
MARYLAND.
LICENSE NUMBER: #15505
EXPIRATION DATE: 8-18-2026
CONSULTANTS:
MWS PROJECT No: 23-082
/6
/2
:4 :4
P
M
PJ-610-230-001
03/05/2026
CODE PLANS - GARAGE
G005
BARRACK J
COMMUNICATION ROOM
& GARAGE
610 TAYLOR AVENUE
ANNAPOLIS, MARYLAND 21401
100% CONSTRUCTION
DOCUMENTS
GLC 09/12/2025
DSO
OCCUPANCY ANALYSIS
NAME AREA FACTOR
OCCUPANT
LOAD
FMD GROUNDS STORAGE 141 SF 300 SF 1
GARAGE & STORAGE ROOMS 3,145 SF 300 SF 11
OFFICE 199 SF 150 SF 2
OFFICE 368 SF 150 SF 3
VEHICLE WASH BAY 492 SF 300 SF 2
1/8" = 1'-0"
GARAGE CODE DIAGRAM
CODE DISTANCES
PATH ID LENGTH
DEAD END
DE-1 8'-9"
DE-2 29'-7"
COMMON PATH
CP-1 34'-6"
CP-2 35'-4"
CP-3 33'-4"
P T
IBC OCCUPANT LOAD LEGEND - GARAGE
CODE DIAGRAM LEGEND - GARAGE
AREA SQUARE FOOTAGES / OCCUPANT LOAD FACTOR = OCCUPANT LOAD
NO. DESCRIPTION DATE
1 ADDENDUM 04 08/07/2026
146006
DN
DUTY
OFFICE
PCO/DISPATCH
FMD
GROUNDS
STORAGE
K-9 WASH
FMD OFFICE
MECHANIC'S
OFFICE
PARTS &
TOOLS
TIRE
STORAGE
FLAMMABLE
OIL
STORAGE
TOILET
MECH/ELEC/AIR
COMPRESSOR
VEHICLE
EVIDENCE
BAY
VEHICLE
MAINT /
SERVICE
BAYS
CORRIDOR
C01
RADIO
COMMUNICATIONS
RADIO
WORKSHOP
VEHICLE
WASH BAY
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
PROJECT No.:
DATE:
SHEET _____ OF _____
SEAL:
DRAWING TITLE:
SHEET NUMBER:BUILDING NUMBER:
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
8098 SANDPIPER CIRCLE, SUITE H
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED
OR APPROVED BY ME, AND THAT I AM A DULY LICENSED
PROFESSIONAL ARCHITECT UNDER THE LAWS OF THE STATE OF
MARYLAND.
LICENSE NUMBER: #15505
EXPIRATION DATE: 8-18-2026
CONSULTANTS:
MWS PROJECT No: 23-082
/6
/2
:4 :4
P
M
PJ-610-230-001
03/05/2026
PROGRAM VALIDATION
G006
BARRACK J
COMMUNICATION ROOM
& GARAGE
610 TAYLOR AVENUE
ANNAPOLIS, MARYLAND 21401
100% CONSTRUCTION
DOCUMENTS
GLC 09/12/2025
DSO
1/8" = 1'-0"
BARRACK PROGRAM VALIDATION
1/8" = 1'-0"
GARAGE PROGRAM VALIDATION
P T
ROOM SQUARE FOOTAGE
NUMBER NAME PROGRAMMED NSF DESIGNATED NSF
101 PCO/DISPATCH 410 SF 269 SF
102 DUTY OFFICE 90 SF 187 SF
103 VEHICLE WASH BAY 455 SF 471 SF
104 VEHICLE MAINT / SERVICE BAYS 1500 SF 1,563 SF
105 VEHICLE EVIDENCE BAY 550 SF 456 SF
106 TOILET 70 SF 58 SF
107 MECHANIC'S OFFICE 135 SF 105 SF
108 K-9 WASH 60 SF 59 SF
109 FLAMMABLE OIL STORAGE 70 SF 69 SF
110 TIRE STORAGE 135 SF 108 SF
111 PARTS & TOOLS 90 SF 83 SF
112 MECH/ELEC/AIR COMPRESSOR * 200 SF
113 RADIO COMMUNICATIONS * 179 SF
114 RADIO WORKSHOP 90 SF 177 SF
115 FMD OFFICE 90 SF 89 SF
116 FMD GROUNDS STORAGE 120 SF 134 SF
TOTAL 4,207 SF
TOTAL NSF: 3,865 NSF
GROSS UP: 30%
TOTAL GSF: 5,047 GSF
TOTAL NSF: 3,831 NSF
GROSS UP: 38%
TOTAL GSF: 5,299 GSF
5,047 GSF X 5% ALLOWABLE OVERAGE = 5,299 GSF
3,831 SF
THE NSF OF ROOMS DENOTED WITH AN ASTERISK *
ARE INCLUDED IN THE OVERALL GROSS UP
PERCENTAGE.
3,865 SF
NO. DESCRIPTION DATE
1 ADDENDUM 04 08/07/2026
146007
DUTY
OFFICE
PCO/DISPATCH
A.S.E.D.
EX132
LOBBY &
WAITING
EX102
VESTIBULE
EX101
TOILET
EX103
CL
EX108
TROOP
COMMANDER
EX107
ASSISTANT
BARRACKS
COMMANDER
EX130
CL
EX131
CL
EX133
ARMS
STORAGE
EX129
SUPERVISORS
EX127
CL
EX128
SECURED
SUPPLIES
EX123
TOILET
EX121
OPEN
SUPPLY
EX120
JAN
EX119
REPORT
ROOM
EX124
CL
EX125
CL
EX126
STAIR #1
EX122
T.W.E.D.
EX117
CL
EX116
CL
EX118 FILE ROOM
EX115
POWDER
EX113
TOILET
EX114
CL
EX112
1ST
SERGEANT
EX111
CL
EX110
BARRACKS
COMMANDER
EX109
CORRIDOR
EX106
A
B
1 2
FMD
GROUNDS
STORAGE
K-9 WASH
FMD OFFICE
MECHANIC'S
OFFICE
PARTS &
TOOLS
TIRE
STORAGE
FLAMMABLE
OIL
STORAGE
109 TOILET
MECH/ELEC/AIR
COMPRESSOR
CORRIDOR
C01
VEHICLE
WASH BAY
RADIO
COMMUNICATIONS
RADIO
WORKSHOP
VEHICLE
MAINT /
SERVICE
BAYS
VEHICLE
EVIDENCE
BAY
1.5 1.7
A.4
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
PROJECT No.:
DATE:
SHEET _____ OF _____
SEAL:
DRAWING TITLE:
SHEET NUMBER:BUILDING NUMBER:
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
8098 SANDPIPER CIRCLE, SUITE H
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED
OR APPROVED BY ME, AND THAT I AM A DULY LICENSED
PROFESSIONAL ARCHITECT UNDER THE LAWS OF THE STATE OF
MARYLAND.
LICENSE NUMBER: #15505
EXPIRATION DATE: 8-18-2026
CONSULTANTS:
MWS PROJECT No: 23-082
/6
/2
:4 :4
P
M
PJ-610-230-001
03/05/2026
ADA PLANS
G008
BARRACK J
COMMUNICATION ROOM
& GARAGE
610 TAYLOR AVENUE
ANNAPOLIS, MARYLAND 21401
100% CONSTRUCTION
DOCUMENTS
GLC 09/12/2025
DSO
1/8" = 1'-0"
BARRACK ADA CLEARANCES
1/8" = 1'-0"
GARAGE ADA CLEARANCES
NO. DESCRIPTION DATE
146009
DN
A
SS
U M
ED
P
RO
PE
RT
Y
LI
N E
A
SS
U M
ED
S
ET
B A
CK
EXISTING BARRACK
BUILDING
EXISTING GARAGE BUILDING
ASSUMED PROPERTY LINE
ASSUMED SETBACK
TAYLOR AVE
CONSTRUCTION STAGING AREA
ENTRY TO REMAIN
ACCESSIBLE AND
OPERATIONAL DURING
CONSTRUCTION
ENTRY TO REMAIN
ACCESSIBLE AND
OPERATIONAL DURING
CONSTRUCTION
SHADED AREA TO BE KEPT CLEAR
FOR OWNER PARKING AND
ACCESS AT ALL TIMES
SHADED AREA TO BE KEPT CLEAR FOR OWNER
PARKING AND ACCESS AT ALL TIMES
P A
R A
LL
E L
P A
R K
IN
G
S P A
C E S T
O B
E R
E S E R V
E D
F O
R G
C
A N
D D
G S C
O N
S T R U
C T
IO
N T
R A
IL
E R S R O
A D
M U
S T
R E M
A
IN
U N
O B S T R U
C T E D
T O
M A
IN
T A
IN
S
IT
E T
R A
F F
IC
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
MARK DATE DESCRIPTION
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
PROJECT No.:
DATE:
SHEET _____ OF _____
DRAWING TITLE:
SHEET NUMBER:BUILDING NUMBER:
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
8098 SANDPIPER CIRCLE, SUITE H
SEAL:
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED
OR APPROVED BY ME, AND THAT I AM A DULY LICENSED
PROFESSIONAL ARCHITECT UNDER THE LAWS OF THE STATE OF
MARYLAND.
LICENSE NUMBER: #15505
EXPIRATION DATE: 8-18-2026
ARCHITECTURE + MASTER PLANNING
MWS PROJECT No: 23-082
CONSULTANTS:
/6
/2
:4 :4
P
M
PJ-610-230-001
03/05/2026
SITE LOGISTICS
A002
BARRACK J
COMMUNICATION ROOM
& GARAGE
610 TAYLOR AVENUE
ANNAPOLIS, MARYLAND 21401
100% CONSTRUCTION
DOCUMENTS
GLC 09/12/2025
DSO
3/32" = 1'-0"
SITE LOGISTICS
P T
NOTE: REMAINDER OF SITE/PARKING NOT
OTHERWISE INDICATED WITH HATCH AND/OR NOTE
SHALL REMAIN ACCESSIBLE / USABLE BY THE OWNER.
COORDINATE WITH AND NOTIFY OWNER / USERS A
MINIMUM OF 72 HOURS IN ADVANCE OF ANY
INTERRUPTIONS OF ACCESS TO THE SITE / PARKING.
LIMIT INTERRUPTIONS TO THE SITE AND EXISTING
PARKING TO THE GREATEST EXTENT POSSIBLE.
NO. DESCRIPTION DATE
146041
VEHICLE
WASH BAY
MECHANIC'S
OFFICE
PARTS &
TOOLS
TIRE
STORAGE
FLAMMABLE
OIL
STORAGE
TOILET
106 MECH/ELEC/AIR
COMPRESSOR
CORRIDOR
C01
VEHICLE
MAINT /
SERVICE
BAYS
VEHICLE
EVIDENCE
BAY
RADIO
COMMUNICATIONS
RADIO
WORKSHOP
A200
A200
A300
A300
A300
DUMPSTER PAD
& ENCLOSURE
A702
A702
116A
OHD6
113A
114A
103A
104A
OHD2 OHD4
104B
OHD5
107A 111A 109A 106A
112A
W2
A701
A200
A200
FMD
GROUNDS
STORAGE
LADDER TO ROOF HATCH
ROOF HATCH LOCATION
OHD1
114B
116B
A300
W1
105A
103B
A702
K-9 WASH
108A
FMD OFFICE
A
B
1 2
A200
A200
OHD3
A300
1.5 1.7
A.4
A500
A500
C L
TY
P.
2'
-0
CLCL
4'-8" 12'-0"
C L
TY
P.
2'
-0
CL
1'-0"
C L C L
3' -2
8'
-2
CLCLCLCLCLCLCLCL
1'-0"
2'-8" 12'-0" 3'-0" 12'-0" 3'-0" 12'-0" 3'-8 1/8"
C L C L
6' -2
TY
P.
2'
-0
CL
1'-0"
CLCL2'-4" 12'-0"
W2
115A
VEHICLE
WASH BAY
MECHANIC'S
OFFICE
PARTS &
TOOLS
111 TIRE
STORAGE
FLAMMABLE
OIL
STORAGE
TOILET
106 MECH/ELEC/AIR
COMPRESSOR
CORRIDOR
C01
VEHICLE
MAINT /
SERVICE
BAYS
VEHICLE
EVIDENCE
BAY
RADIO
COMMUNICATIONS
RADIO
WORKSHOP
33'-10" 47'-4" 17'-2" 9'-8"
98'-4"
3' -0
3'
-4
3' -0
E02
E02
E01
E01
E01
E05
M08B
M10
M08A
M08B
M08B
M08B
M08A
M08A
A
LI
G N
A
LI
G N
ALIGN
M08B
A
LI
G N
E03
E03
M08C M08C
M08C
FMD
GROUNDS
STORAGE
2' -3
8'
-0
1' -4
3'
-4
0" 3'
-4
4' -0
9'
-4
/2
4'-8" 12'-0" 4'-0" 3'-4" 2'-4" 6'-0" 1'-6" 2'-8" 12'-0" 3'-0" 12'-0" 3'-0" 12'-0" 2'-8" 2'-4" 12'-0" 2'-10"
6'-8" 5'-4"
4'-0" 6'-3" 3'-4" 7'-4" 6'-8" 3'-0"
C L
TY
P.
2'
-0
M08A
47'-6" 20'-0" 32'-2"
C L C L
1' -4
4"
1' -4
5' -4
5/
8"8' -3
/4
M10
5'-4" 6'-8"
E04 1'-3" 9'-4 5/8" 7 5/8" 7'-4" 7 5/8" 10'-8" 7 5/8" 12'-8" 7 5/8" 10'-0" 7 5/8" 13'-0" 7 5/8" 8'-4" 7 5/8" 7'-0" 7 5/8" 13'-7 3/8" 1'-4"1"
3' -0
3'
-4
3' -0
C L
TY
P.
2'
-0
C L
TY
P.
2' -0
1/
2"
18'-4"
7 5/8"
2'-8" 3'-4"
1'-0"
8"
A
B
1 2
5"
E04 E05
0"
-1"
-3/4"
0"
0"0"
0"
M08B
M08A
M08B
K-9 WASH
FMD OFFICE
C L 9'
-4
1.5 1.7
A.4
4"
11'-8" 99'-8"
E05
M08B
1'-4" 4'-0"
EXISTING WALL TO REMAIN
EXISTING CONSTRUCTION TO BE
DEMOLISHED (SEE DEMO PLANS)
NEW WALL/PARTITION
PLAN LEGEND
NEW CMU WALL
NEW CONCRETE RETAINING WALL
1/8" = 1'-0"
GARAGE REFERENCE PLAN
1/8" = 1'-0"
GARAGE DIMENSION PLAN
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
PROJECT No.:
DATE:
SHEET _____ OF _____
SEAL:
DRAWING TITLE:
SHEET NUMBER:BUILDING NUMBER:
B2
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
8098 SANDPIPER CIRCLE, SUITE H
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED
OR APPROVED BY ME, AND THAT I AM A DULY LICENSED
PROFESSIONAL ARCHITECT UNDER THE LAWS OF THE STATE OF
MARYLAND.
LICENSE NUMBER: #15505
EXPIRATION DATE: 8-18-2026
CONSULTANTS:
MWS PROJECT No: 23-082
/6
/2
:4 :4
P
M
PJ-610-230-001
03/05/2026
REFERENCE & DIMENSION
PLAN - GARAGE
A102
BARRACK J
COMMUNICATION ROOM
& GARAGE
610 TAYLOR AVENUE
ANNAPOLIS, MARYLAND 21401
100% CONSTRUCTION
DOCUMENTS
GLC 09/12/2025
DSO
GENERAL DIMENSION PLAN NOTES
1 G.C. SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. REPORT ANY
DISCREPANCIES TO THE ARCHITECT BEFORE PROCEEDING WITH ANY WORK.
2 ALL DOOR JAMBS IN METAL STUD WALL SHALL BE A MINIMUM OF 4" FROM ADJACENT / PERPENDICULAR WALLS UNLESS NOTED
OTHERWISE.
P T
NO. DESCRIPTION DATE
146050
UP
FEC
FEC
DN
DN
UP
EXISTING WALL TO REMAIN
EXISTING CONSTRUCTION TO BE
DEMOLISHED (SEE DEMO PLANS)
NEW WALL/PARTITION
PLAN LEGEND
NEW CMU WALL
NEW CONCRETE RETAINING WALL
DUTY
OFFICE
PCO/DISPATCH
TRASH & RECYCLING
EQ-05 EQ-06
EQ-08EQ-04EQ-07
EQ-03
FILE ROOM
EX115
T.W.E.D.
EX117
STAIR #1
EX122
REPORT
ROOM
EX124
POWDER
EX113
TOILET
EX114
1ST
SERGEANT
EX111
BARRACKS
COMMANDER
EX109
TROOP
COMMANDER
EX107
TOILET
EX121 OPEN
SUPPLY
EX120
SECURED
SUPPLIES
EX123
SUPERVISORS
EX127
ARMS
STORAGE
EX129
ASSISTANT
BARRACKS
COMMANDER
EX130
A.S.E.D.
EX132
LOBBY &
WAITING
EX102
VESTIBULE
EX101
TOILET
EX103
KEY BOX
DUTY
OFFICE
PCO/DISPATCH
LVT-1
LVT-1
A.S.E.D.
EX132
ASSISTANT
BARRACKS
COMMANDER
EX130
ARMS
STORAGE
EX129
SUPERVISORS
EX127
REPORT
ROOM
EX124
STAIR #1
EX122
T.W.E.D.
EX117
FILE ROOM
EX115
POWDER
EX113
TOILET
EX114
1ST
SERGEANT
EX111
OPEN
SUPPLY
EX120
TOILET
EX121
SECURED
SUPPLIES
EX123
BARRACKS
COMMANDER
EX109
TROOP
COMMANDER
EX107
VESTIBULE
EX101
TOILET
EX103
LOBBY &
WAITING
EX102
FT-1
FT-1
6"
6'-1" 3'-9" 4'-2"
REPAINT LOBBY WALLS PT-1
1/8" = 1'-0"
BARRACK FINISH PLAN
SCHEDULE - EQUIPMENT
MARK DESCRIPTION BOD MANUFACTURER BOD MODEL
OWNER
FURNISH AND
INSTALL
OWNER
FURNISH
CONTRACTOR
INSTALL
CONTRACTOR
FURNISH AND
INSTALL COMMENTS
EQ-01 CAR LIFT ROTARY LIFT SPOA10-TRIO-FA ●
EQ-02 96"W x 18"D x 84"H TIRE RACK ULINE H-4882 ●
EQ-03 EVIDENCE DROP N/A N/A ● EXISTING TO BE REUSED
EQ-04 PRINTER N/A N/A ● EXISTING TO BE REUSED
EQ-05 SURFACE MOUNTED GUN LOCKER FASCO SECURITY PRODUCTS FLC-707-4W ●
EQ-06 RECESSED RIFLE LOCKER FASCO SECURITY PRODUCTS FLC-71653 ●
EQ-07 SHREDDER N/A N/A ● EXISTING TO BE REUSED
EQ-08 UNDERCOUNTER REFRIGERATOR WHIRLPOOL WUR35X24HZ ●
EQ-10 6'-0"W x 7'-4"H WIRE MESH DOOR WIRECRAFTER DOUBLE-HINGED DOOR ●
EQ-11 CEILING FAN BIG ASS FANS POWERFOIL D ●
EQ-12 WIRE SHELVING NEXEL INDUSTRIES 48"D x 24"W WIRE SHELVING ●
EQ-13 OPEN CAR LIFT ROTARY LIFT SM14N102Y ●
SCHEDULE - MATERIAL FINISH KEY
FINISH MARK DESCRIPTION BOD MANUFACTURER BOD MODEL/PRODUCT LINE BOD COMMENTS
B-1 4" RUBBER BASE JOHNSONITE TRADITIONAL RUBBER BASE - 167 FUDGE
B-2 4" RUBBER BASE JOHNSONITE TRADITIONAL RUBBER BASE - 21 PLATINUM CG
B-3 4" RESINOUS COVE BASE SIKA DECODUR FLAKE FX 1/8" - GREYSTOKE
FRP-1 FIBERGLASS REINFORCED PLASTIC PANEL MARLITE STANDARD FRP - WHITE
HPC-1 HIGH PERFORMANCE COATING SHERWIN WILLIAMS SW 7551 GREEK VILLA
LVT-1 LUXURY VINYL TILE AHF CONTRACT NOD TO NATURE USA - REDWOOD BARK
P-1 PAINT SHERWIN WILLIAMS SW 7551 GREEK VILLA
PL-1 PLASTIC LAMINATE WILSON ART 8218-38 KINGSWOOD WALNUT
QZ-1 QUARTZ COUNTERTOP CORIAN OYSTER GRIGIO
RES-1 RESINOUS FLOORING SHERWIN WILLIAMS RESUFLOR GARD - COLOR TO BE SELECTED BY ARCHITECT
RES-2 RESINOUS WALL COVERING SHERWIN WILLIAMS RESUWALL HPF - COLOR TO BE SELECTED BY ARCHITECT
SC-1 SEALED CONCRETE SEE SPECS SEE SPECS
SDT-1 12" x 12" STATIC DISSIPATIVE TILE ARMSTRONG EXCELON SDT - 51953 PEARL WHITE
VCT-1 12" x 12" VINYL COMPOSITE TILE ARMSTRONG STANDARD EXCELON IMPERIAL TEXTURE - 51911 CLASSIC WHITE
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
PROJECT No.:
DATE:
SHEET _____ OF _____
SEAL:
DRAWING TITLE:
SHEET NUMBER:BUILDING NUMBER:
B1
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
8098 SANDPIPER CIRCLE, SUITE H
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED
OR APPROVED BY ME, AND THAT I AM A DULY LICENSED
PROFESSIONAL ARCHITECT UNDER THE LAWS OF THE STATE OF
MARYLAND.
LICENSE NUMBER: #15505
EXPIRATION DATE: 8-18-2026
CONSULTANTS:
MWS PROJECT No: 23-082
/6
/2
:2 :4
P
M
PJ-610-230-001
03/05/2026
EQUIPMENT, FFE & FINISH
PLANS - BARRACK
A111
BARRACK J
COMMUNICATION ROOM
& GARAGE
610 TAYLOR AVENUE
ANNAPOLIS, MARYLAND 21401
100% CONSTRUCTION
DOCUMENTS
GLC 09/12/2025
DSO
1/8" = 1'-0"
BARRACK EQUIPMENT & FFE PLAN P T
NOTE: EQUIPMENT (TAGGED EQ-X) AND OWNER PROVIDED FURNITURE ARE SHOWN BOLDED; FURNITURE IS SHOWN FOR INFORMATIONAL PURPOSES ONLY. FINAL FURNISHINGS AND LOCATIONS MAY CHANGE. ITEMS
TO BE INSTALLED IN RELATION TO FURNITURE SHALL BE COORDINATED WITH OWNER PRIOR TO ROUGH-IN OR
BLOCKING INSTALLATION.
NO. DESCRIPTION DATE
146051
EXISTING WALL TO REMAIN
EXISTING CONSTRUCTION TO BE
DEMOLISHED (SEE DEMO PLANS)
NEW WALL/PARTITION
PLAN LEGEND
NEW CMU WALL
NEW CONCRETE RETAINING WALL
VEHICLE
WASH BAY
MECHANIC'S
OFFICE
PARTS &
TOOLS
TIRE
STORAGE
FLAMMABLE
OIL
STORAGE
TOILET
MECH/ELEC/AIR
COMPRESSOR
CORRIDOR
C01
VEHICLE
MAINT /
SERVICE
BAYS
VEHICLE
EVIDENCE
BAY
RADIO
COMMUNICATIONS
RADIO
WORKSHOP
EQ-02
EQ-10
EQ-01
FMD
GROUNDS
STORAGE
EQ-12 EQ-12
EXTENT OF OWNER STORAGE
TYP.
2'-0"
K-9 WASH
FMD OFFICE
EQ-13
VEHICLE
WASH BAY
RADIO
COMMUNICATIONS
RADIO
WORKSHOP
VEHICLE
MAINT /
SERVICE
BAYS
VEHICLE
EVIDENCE
BAY
MECH/ELEC/AIR
COMPRESSOR
TOILET
FLAMMABLE
OIL
STORAGE
TIRE
STORAGE
PARTS &
TOOLS
MECHANIC'S
OFFICE
CORRIDOR
C01
FMD
GROUNDS
STORAGE
SC-1
SC-1 SC-1
SC-1
SC-1
RES-1
RES-1
RES-1
SDT-1
SDT-1
RES-1
VCT-1
VCT-1
K-9 WASH
108 FMD OFFICE
FT-2FT-2
FT-3
FT-4
FT-3
FT-3
FT-3
FT-3
SEAL JOINT BETWEEN BOTTOM OF WALL AND
FLOOR SLAB TO CREATE LIQUID-TIGHT SEAL
AROUND ENTIRE PERIMETER OF ROOM. SEE DETAIL
1/A601 FOR FINISH TRANSITION.
RES-1
SC-1
FT-3
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
PROJECT No.:
DATE:
SHEET _____ OF _____
SEAL:
DRAWING TITLE:
SHEET NUMBER:BUILDING NUMBER:
B2
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
8098 SANDPIPER CIRCLE, SUITE H
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED
OR APPROVED BY ME, AND THAT I AM A DULY LICENSED
PROFESSIONAL ARCHITECT UNDER THE LAWS OF THE STATE OF
MARYLAND.
LICENSE NUMBER: #15505
EXPIRATION DATE: 8-18-2026
CONSULTANTS:
MWS PROJECT No: 23-082
/6
/2
:2 :0
P
M
PJ-610-230-001
03/05/2026
EQUIPMENT, FFE & FINISH
PLANS - GARAGE
A112
BARRACK J
COMMUNICATION ROOM
& GARAGE
610 TAYLOR AVENUE
ANNAPOLIS, MARYLAND 21401
100% CONSTRUCTION
DOCUMENTS
GLC 09/12/2025
DSO
1/8" = 1'-0"
GARAGE EQUIPMENT & FFE PLAN
1/8" = 1'-0"
GARAGE FINISH PLAN
SCHEDULE - EQUIPMENT
MARK DESCRIPTION BOD MANUFACTURER BOD MODEL
OWNER
FURNISH AND
INSTALL
OWNER
FURNISH
CONTRACTOR
INSTALL
CONTRACTOR
FURNISH AND
INSTALL COMMENTS
EQ-01 CAR LIFT ROTARY LIFT SPOA10-TRIO-FA ●
EQ-02 96"W x 18"D x 84"H TIRE RACK ULINE H-4882 ●
EQ-03 EVIDENCE DROP N/A N/A ● EXISTING TO BE REUSED
EQ-04 PRINTER N/A N/A ● EXISTING TO BE REUSED
EQ-05 SURFACE MOUNTED GUN LOCKER FASCO SECURITY PRODUCTS FLC-707-4W ●
EQ-06 RECESSED RIFLE LOCKER FASCO SECURITY PRODUCTS FLC-71653 ●
EQ-07 SHREDDER N/A N/A ● EXISTING TO BE REUSED
EQ-08 UNDERCOUNTER REFRIGERATOR WHIRLPOOL WUR35X24HZ ●
EQ-10 6'-0"W x 7'-4"H WIRE MESH DOOR WIRECRAFTER DOUBLE-HINGED DOOR ●
EQ-11 CEILING FAN BIG ASS FANS POWERFOIL D ●
EQ-12 WIRE SHELVING NEXEL INDUSTRIES 48"D x 24"W WIRE SHELVING ●
EQ-13 OPEN CAR LIFT ROTARY LIFT SM14N102Y ●
SCHEDULE - MATERIAL FINISH KEY
FINISH MARK DESCRIPTION BOD MANUFACTURER BOD MODEL/PRODUCT LINE BOD COMMENTS
B-1 4" RUBBER BASE JOHNSONITE TRADITIONAL RUBBER BASE - 167 FUDGE
B-2 4" RUBBER BASE JOHNSONITE TRADITIONAL RUBBER BASE - 21 PLATINUM CG
B-3 4" RESINOUS COVE BASE SIKA DECODUR FLAKE FX 1/8" - GREYSTOKE
FRP-1 FIBERGLASS REINFORCED PLASTIC PANEL MARLITE STANDARD FRP - WHITE
HPC-1 HIGH PERFORMANCE COATING SHERWIN WILLIAMS SW 7551 GREEK VILLA
LVT-1 LUXURY VINYL TILE AHF CONTRACT NOD TO NATURE USA - REDWOOD BARK
P-1 PAINT SHERWIN WILLIAMS SW 7551 GREEK VILLA
PL-1 PLASTIC LAMINATE WILSON ART 8218-38 KINGSWOOD WALNUT
QZ-1 QUARTZ COUNTERTOP CORIAN OYSTER GRIGIO
RES-1 RESINOUS FLOORING SHERWIN WILLIAMS RESUFLOR GARD - COLOR TO BE SELECTED BY ARCHITECT
RES-2 RESINOUS WALL COVERING SHERWIN WILLIAMS RESUWALL HPF - COLOR TO BE SELECTED BY ARCHITECT
SC-1 SEALED CONCRETE SEE SPECS SEE SPECS
SDT-1 12" x 12" STATIC DISSIPATIVE TILE ARMSTRONG EXCELON SDT - 51953 PEARL WHITE
VCT-1 12" x 12" VINYL COMPOSITE TILE ARMSTRONG STANDARD EXCELON IMPERIAL TEXTURE - 51911 CLASSIC WHITE
NOTE: EQUIPMENT (TAGGED EQ-X) AND OWNER PROVIDED FURNITURE ARE SHOWN BOLDED; FURNITURE IS SHOWN FOR INFORMATIONAL PURPOSES ONLY. FINAL FURNISHINGS AND LOCATIONS MAY CHANGE. ITEMS
TO BE INSTALLED IN RELATION TO FURNITURE SHALL BE COORDINATED WITH OWNER PRIOR TO ROUGH-IN OR
BLOCKING INSTALLATION.
P T
NO. DESCRIPTION DATE
146052
VCT - RESINOUS FLOOR
FT-2
DOOR, WHERE
APPLICABLE
VCT
RESINOUS FLOOR, TYP.
SDT - RESINOUS FLOOR
FT-4
LVT - EXISTING FLOORING
FT-1
RESINOUS FLOOR - CONCRETE
FT-3
DOOR, WHERE
APPLICABLE
SDT
STAINLESS STEEL
DIVIDER STRIP, TYP.
RESINOUS FLOOR, TYP.
DOOR, WHERE
APPLICABLE
RESINOUS
FLOOR, TYP.
STAINLESS STEEL
DIVIDER STRIP, TYP.
CONCRETE
(STAINED OR
SEALED)
DOOR, WHERE
APPLICABLE
LVT
VINYL TRANSITION
STRIP, BASIS OF DESIGN
ARMSTRONG VT7
EXISTING FLOORING
STAINLESS STEEL
DIVIDER STRIP, TYP.
4" 7' -0
CAUTION WATCH YOUR STEP
109A
PAINTED WARNING. CENTER
TEXT UNDER DOOR.
CAST-IN-PLACE CONCRETE CURB
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
MARK DATE DESCRIPTION
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
PROJECT No.:
DATE:
SHEET _____ OF _____
DRAWING TITLE:
SHEET NUMBER:BUILDING NUMBER:
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
OR APPROVED BY ME, AND THAT I AM A DULY LICENSED
PROFESSIONAL ARCHITECT UNDER THE LAWS OF THE STATE OF
MARYLAND.
LICENSE NUMBER: #15505
EXPIRATION DATE: 8-18-2026
ARCHITECTURE + MASTER PLANNING
MWS PROJECT No: 23-082
CONSULTANTS:
/6
/2
:2 :1
P
M
PJ-610-230-001
03/05/2026
FINISH SCHEDULES, NOTES,
& DETAILS
A113
BARRACK J
COMMUNICATION ROOM
& GARAGE
610 TAYLOR AVENUE
ANNAPOLIS, MARYLAND 21401
100% CONSTRUCTION
DOCUMENTS
GLC 09/12/2025
DSO
SCHEDULE - MATERIAL FINISH KEY
FINISH MARK DESCRIPTION BOD MANUFACTURER BOD MODEL/PRODUCT LINE BOD COMMENTS
B-1 4" RUBBER BASE JOHNSONITE TRADITIONAL RUBBER BASE - 167 FUDGE
B-2 4" RUBBER BASE JOHNSONITE TRADITIONAL RUBBER BASE - 21 PLATINUM CG
B-3 4" RESINOUS COVE BASE SIKA DECODUR FLAKE FX 1/8" - GREYSTOKE
FRP-1 FIBERGLASS REINFORCED PLASTIC PANEL MARLITE STANDARD FRP - WHITE
HPC-1 HIGH PERFORMANCE COATING SHERWIN WILLIAMS SW 7551 GREEK VILLA
LVT-1 LUXURY VINYL TILE AHF CONTRACT NOD TO NATURE USA - REDWOOD BARK
P-1 PAINT SHERWIN WILLIAMS SW 7551 GREEK VILLA
PL-1 PLASTIC LAMINATE WILSON ART 8218-38 KINGSWOOD WALNUT
QZ-1 QUARTZ COUNTERTOP CORIAN OYSTER GRIGIO
RES-1 RESINOUS FLOORING SHERWIN WILLIAMS RESUFLOR GARD - COLOR TO BE SELECTED BY ARCHITECT
RES-2 RESINOUS WALL COVERING SHERWIN WILLIAMS RESUWALL HPF - COLOR TO BE SELECTED BY ARCHITECT
SC-1 SEALED CONCRETE SEE SPECS SEE SPECS
SDT-1 12" x 12" STATIC DISSIPATIVE TILE ARMSTRONG EXCELON SDT - 51953 PEARL WHITE
VCT-1 12" x 12" VINYL COMPOSITE TILE ARMSTRONG STANDARD EXCELON IMPERIAL TEXTURE - 51911 CLASSIC WHITE
SCHEDULE - FINISHES
ROOM INFORMATION FLOOR
FINISH BASE
WALL FINISH CEILING
FINISH REMARKSRM # ROOM NAME NORTH SOUTH EAST WEST
101 PCO/DISPATCH LVT-1 B-1 P-1 P-1 P-1 P-1 CLG-3
102 DUTY OFFICE LVT-1 B-1 P-1 P-1 P-1 P-1 CLG-3
103 VEHICLE WASH BAY RES-1 B-3 HPC-1 HPC-1 HPC-1 HPC-1 CLG-4
104 VEHICLE MAINT / SERVICE BAYS RES-1 B-3 HPC-1 HPC-1 HPC-1 HPC-1 CLG-4
105 VEHICLE EVIDENCE BAY RES-1 B-3 HPC-1 HPC-1 HPC-1 HPC-1 CLG-4
106 TOILET RES-1 B-3 P-1 P-1 P-1 P-1 CLG-1
107 MECHANIC'S OFFICE VCT-1 B-2 PAINTED CMU PAINTED CMU PAINTED CMU PAINTED CMU CLG-2
108 K-9 WASH RES-1 B-3 P-1 P-1 P-1 P-1 CLG-3
109 FLAMMABLE OIL STORAGE SC-1 - - HPC-1 HPC-1 HPC-1 HPC-1 CLG-2
110 TIRE STORAGE RES-1 B-3 HPC-1 HPC-1 HPC-1 HPC-1 CLG-2
111 PARTS & TOOLS SC-1 - - HPC-1 HPC-1 HPC-1 HPC-1 CLG-1
112 MECH/ELEC/AIR COMPRESSOR SC-1 - - HPC-1 HPC-1 HPC-1 HPC-1 EXPOSED
113 RADIO COMMUNICATIONS SDT-1 B-2 PAINTED CMU PAINTED CMU PAINTED CMU PAINTED CMU EXPOSED
114 RADIO WORKSHOP SDT-1 B-2 PAINTED CMU PAINTED CMU PAINTED CMU PAINTED CMU CLG-1
115 FMD OFFICE VCT-1 B-2 PAINTED CMU PAINTED CMU PAINTED CMU PAINTED CMU CLG-1
116 FMD GROUNDS STORAGE SC-1 - - HPC-1 HPC-1 HPC-1 HPC-1 EXPOSED
C01 CORRIDOR RES-1 B-3 PAINTED CMU PAINTED CMU PAINTED CMU PAINTED CMU CLG-1
1 1/2" = 1'-0"
FLOORING TRANSITION DETAILS
3/4" = 1'-0"
DOOR 109A ELEVATION
NO. DESCRIPTION DATE
146053
GARAGE FLOOR
0"
A300
A300
A300
1 1.5 1.7 2
1 2
OHD1 OHD2 OHD4 OHD5
114A
W1
EF-1EF-1 EF-1
EF-2
EF-2
EF-2
EF-2
EF-2 EF-2
T.O. MASONRY - HIGH
25'-8"
T.O. MASONRY - LOW
23'-4"
OHD3
EF-3
EF-4
GARAGE FLOOR
0"
A300
TOPOGRAPHY
BEYOND
A A.4 B
A B
EF-1
116A 103A
T.O. MASONRY - LOW
23'-4"
A300
EF-2
EF-2
EF-4
A.4
GARAGE FLOOR
0"
B
B
EF-1
EF-2
104A
T.O. MASONRY - HIGH
25'-8"
T.O. MASONRY - LOW
23'-4"
EF-4
EF-3
4' -8
GARAGE FLOOR
0"
B
B
EF-1
EF-2
104B
T.O. MASONRY - HIGH
25'-8"
T.O. MASONRY - LOW
23'-4"
EF-4
EF-3
GARAGE FLOOR
0"
A300
AA.4B
AB
T.O. MASONRY - LOW
23'-4"
A300
EF-3
EF-1
A.4
GARAGE FLOOR
0"
A300
A300
A300
11.51.72
T.O. MASONRY - LOW
23'-4"
EF-1
1.51.7
W4
REFERENCED NOTES - ELEVATIONS
1 METAL COPING
2 BRICK VENEER
3 BRICK SOLDIER COURSE HEADER, TYP
4 OVERHEAD DOOR
5 WALL SCONCE, CENTER ON OPENING, TYP.
6 COILING DOOR
7 EQUIPMENT SCREENING, TYP.
8 BRICK SOLDIER COURSE BANDING, TYP.
9 BOLLARD, TYP.
10 APPROXIMATE LINE OF GRADE.
11 STEP CONCRETE RETAINING WALL THICKNESS TO ALLOW BRICK FINISH TO EXTEND
8"MIN-16"MAX BELOW GRADE.
12 DOUBLE BRICK SOLDIER COURSE BANDING, TYP.
13 BRICK ROWLOCK SILL, TYP.
14 KNOX BOX, TYP.
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
PROJECT No.:
DATE:
SHEET _____ OF _____
SEAL:
DRAWING TITLE:
SHEET NUMBER:BUILDING NUMBER:
B2
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
8098 SANDPIPER CIRCLE, SUITE H
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED
OR APPROVED BY ME, AND THAT I AM A DULY LICENSED
PROFESSIONAL ARCHITECT UNDER THE LAWS OF THE STATE OF
MARYLAND.
LICENSE NUMBER: #15505
EXPIRATION DATE: 8-18-2026
CONSULTANTS:
MWS PROJECT No: 23-082
/7
/2
:1 :3
P
M
PJ-610-230-001
03/05/2026
BUILDING ELEVATIONS
A200
BARRACK J
COMMUNICATION ROOM
& GARAGE
610 TAYLOR AVENUE
ANNAPOLIS, MARYLAND 21401
100% CONSTRUCTION
DOCUMENTS
GLC 09/12/2025
DSO
1/8" = 1'-0"
GARAGE - SOUTH ELEVATION
1/8" = 1'-0"
GARAGE - WEST ELEVATION
1/8" = 1'-0"
GARAGE - WEST ELEVATION 02
1/8" = 1'-0"
GARAGE - EAST ELEVATION 02
SCHEDULE - EXTERIOR MATERIAL FINISH KEY
FINISH MARK DESCRIPTION BOD MANUFACTURER BOD MODEL/PRODUCT LINE BOD COMMENTS
EF-1 STANDARD BRICK VENEER BOWERSTON #942 DARK GREY W/C MODULAR
EF-2 BRICK SOLDIER COURSE BANDING GLEN GERY WILLIAMSBURG SADDLE BROWN
EF-3 PRE-FINISHED ALUMINIUM COPING - - - -
EF-4 BOLLARD COVERING SEE SPECS TBD
1/8" = 1'-0"
GARAGE - EAST ELEVATION
1/8" = 1'-0"
GARAGE - NORTH ELEVATION
NO. DESCRIPTION DATE
1 ADDENDUM 04 08/07/2026
146057
VARIES
V
AR
IE
S
VARIES
V
AR
IE
S
6" VARIES 6"
8" V
AR
IE
S 3'
-6
F G
GLAZING
SEE
SCHEDULE
VARIES
6" VARIES 6"
1. SEE DOOR SCHEDULE FOR ACTUAL PANEL DIMENSIONS.
2. NOT ALL PANEL TYPES MAY BE USED IN THIS PROJECT, SEE DOOR SCHEDULE.
3. DIMENSIONS FOR GLAZING INDICATED SHALL CONSTITUTE THE FULL GLAZING WIDTH.
4. SEE STOREFRONT ELEVATIONS FOR CURTAIN WALL / STOREFRONT ENTRANCE
V
VARIES
V
AR
IE
S
5' -6
1'-0" 1'-0" 1'-0"
GLAZING
SEE
SCHEDULE
HOLLOW METAL STANDARD
FRAME
JAMB VARIES JAMB VARIES
PANEL(S) WIDTH VARIES
D O
O R
PA
N
EL
(S
H
EI
G
H T
V
AR
IE
S
H
EA
D V
AR
IE
S
OVERALL WIDTH VARIES
O V
ER
AL
L H
EI
G
H T
V
AR
IE
S
HM ST
D1
1. SEE OVERHEAD DOOR SCHEDULE FOR ACTUAL PANEL DIMENSIONS.
2. NOT ALL PANEL TYPES MAY BE USED IN THIS PROJECT, SEE DOOR SCHEDULE.
3. DIMENSIONS FOR GLAZING INDICATED SHALL CONSTITUTE THE FULL GLAZING WIDTH.
4. ALL DOOR PANELS (SOLID OR GLASS) SHALL MEET THE ENERGY EFFICIENCY REQUIRED FOR A BUILDING ENVELOPE IN THE IECC.
D2
SOLID PANELS, TYP.
SOLID PANELS, TYP.
D3
FLOOR LEVEL
12'-0"
1"
1"
12'-0"
8'-6"
8' -3
GLASS PANELS, TYP.
SCHEDULE - DOOR
MARK
DOOR PANEL FRAME GLAZING DETAILS
HARDWARE
SET COMMENTS MARKSIZE TYPE THICKNESS MATERIAL FINISH FRAME TYPE
SIZE SUMMARY FRAME PROFILE SUMMARY
SIDE LITE
WIDTH MATERIAL FINISH THICKNESS TYPE HEAD JAMB THRESHOLD
OVERALL
HEIGHT
OVERALL
WIDTH DEPTH THROAT HEAD JAMB
101A 3'-0" x 7'-0" PANEL : G 1 3/4" INSULATED HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 1" GL2 H4 J4 FT-1 05 101A
102A 3'-0" x 7'-0" PANEL : G 1 3/4" INSULATED HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 1" GL2 H4 J4 FT-1 05 102A
103A 3'-0" x 7'-0" PANEL : V 1 3/4" INSULATED HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 1" GL4 H1B J1B S1 02 103A
103B 3'-0" x 7'-0" PANEL : F 1 3/4" HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 0" - - H2A J2A FT-3 10 103B
104A 3'-0" x 7'-0" PANEL : V 1 3/4" INSULATED HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 1" GL4 H1A J1A S1 01 104A
104B 3'-0" x 7'-0" PANEL : V 1 3/4" INSULATED HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 1" GL4 H1A J1A S1 01 104B
105A 3'-0" x 7'-0" PANEL : F 1 3/4" HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 0" - - H2B J2B - - 11 105A
106A 3'-0" x 7'-0" PANEL : F 1 3/4" HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 0" - - H2A J2A - - 06 106A
107A 3'-0" x 7'-0" PANEL : G 1 3/4" HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 1/4" GL1 H2A J2A FT-2 03 107A
108A 3'-0" x 7'-0" PANEL : G 1 3/4" HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 1/4" GL1 H3 J3 FT-3 08 180 DEGREE HINGES, DOOR FRAME TO BE FLUSH WITH THE
CORRIDOR FACE OF CMU.
108A
109A 3'-0" x 6'-8" PANEL : F 1 3/4" HOLLOW METAL PAINTED HM ST 7'-0" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 0" - - H3 J3 1/A601 07 180 DEGREE HINGES, DOOR FRAME TO BE FLUSH WITH THE
CORRIDOR FACE OF CMU.
109A
111A 3'-0" x 7'-0" PANEL : F 1 3/4" HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 0" - - H3 J3 - - 14 180 DEGREE HINGES, DOOR FRAME TO BE FLUSH WITH THE
CORRIDOR FACE OF CMU.
111A
112A 3'-6" x 7'-0" PANEL : F 1 3/4" HOLLOW METAL PAINTED HM ST 7'-4" 3'-10" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 0" - - H2A J2A - - 09 112A
113A 3'-0" x 7'-0" PANEL : F 1 3/4" HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 0" - - H2A J2A - - 13 113A
114A 3'-0" x 7'-0" PANEL : V 1 3/4" INSULATED HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 1" GL4 H1A J1A S1 01 114A
114B 3'-0" x 7'-0" PANEL : G 1 3/4" HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 1/4" GL1 H2A J2B FT-4 04 114B
115A 3'-0" x 7'-0" PANEL : F 1 3/4" HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 0" - - H2A J2A FT-2 03 115A
116A 3'-0" x 7'-0" PANEL : F 1 3/4" INSULATED HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 0" - - H1B J1B S1 01 116A
116B 3'-0" x 7'-0" PANEL : F 1 3/4" HOLLOW METAL PAINTED HM ST 7'-4" 3'-4" 5 7/8" 4 7/8" 4" 2" 0" HM PAINTED 0" - - H2A J2A - - 12 116B
1/2" = 1'-0"
DOOR PANEL TYPES
1/2" = 1'-0"
FRAME TYPES
SCHEDULE - GLAZING
MARK DESCRIPTION COMMENTS
GL1 CLEAR TEMPERED GLASS
GL2 INSULATED, CLEAR GLAZING
GL3 LEVEL 8 BALLISTIC GLAZING
GL4 EXTERIOR, LOW-E, INSULATED SAFETY GLAZING
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
MARK DATE DESCRIPTION
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
PROJECT No.:
DATE:
SHEET _____ OF _____
DRAWING TITLE:
SHEET NUMBER:BUILDING NUMBER:
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
OR APPROVED BY ME, AND THAT I AM A DULY LICENSED
PROFESSIONAL ARCHITECT UNDER THE LAWS OF THE STATE OF
MARYLAND.
LICENSE NUMBER: #15505
EXPIRATION DATE: 8-18-2026
ARCHITECTURE + MASTER PLANNING
MWS PROJECT No: 23-082
CONSULTANTS:
/6
/2
:4 :4
P
M
PJ-610-230-001
03/05/2026
DOOR SCHEDULE & DETAILS
A600
BARRACK J
COMMUNICATION ROOM
& GARAGE
610 TAYLOR AVENUE
ANNAPOLIS, MARYLAND 21401
100% CONSTRUCTION
DOCUMENTS
GLC 09/12/2025
DSO
1/2" = 1'-0"
OVERHEAD DOOR PANEL TYPES
SCHEDULE - OVERHEAD DOORS
MARK PANEL TYPE
DOOR SIZE DETAIL
COMMENTSHEIGHT WIDTH HEAD JAMB THRESHOLD
OHD1 D2 12'-0" 12'-0" OH1 OJ1 OT1
OHD2 D1 12'-0" 12'-0" OH1 OJ1 OT1
OHD3 D1 12'-0" 12'-0" OH1 OJ1 OT1
OHD4 D1 12'-0" 12'-0" OH1 OJ1 OT1
OHD5 D2 12'-0" 12'-0" OH1 OJ1 OT1
OHD6 D3 8'-0" 8'-0" OH2 OJ2 OT2
NO. DESCRIPTION DATE
1 ADDENDUM 04 08/07/2026
146063
H2A
HM FRAME, FULLY GROUTED,
CENTERED ON CMU, TYP.
CONT. SEALANT BOTH
SIDES, TYP.
PRECAST LINTEL, TYP.
7 5/8"
PAINTED CMU WALL
WHERE INDICATED, TYP.
H2B
HM FRAME, FULLY GROUTED,
CENTERED ON CMU, TYP.
CONT. SEALANT BOTH
SIDES, TYP.
9 5/8"
PAINTED CMU WALL
WHERE INDICATED, TYP.
H3
HM FRAME, FULLY GROUTED, TYP.
FRAME FLUSH WITH CORRIDOR
SIDE OF WALL.
CONT. SEALANT BOTH
SIDES, TYP.
7 5/8"
PAINTED CMU WALL
WHERE INDICATED, TYP.
H1A
3 5/8" 1 3/4" 2" 9 5/8"
5/8"
BRICK VENEER, TYP.
AIR SPACE, TYP.
RIGID INSULATION, TYP.
CONT. WEATHER RESISTIVE
BARRIER, TYP.
PRE-FINISHED METAL DRIP
EDGE WITH FLEXIBLE
THROUGH WALL METAL
FLASHING, TYP.
CAVITY LINTEL PAINTED
WITH HPC-1 WHERE
EXPOSED, TYP.
PAINTED CMU WALL, TYP.
MASONRY BOND BEAD, TYP.
CONT. SEALANT BOTH
SIDES, TYP.
HM FRAME, FULLY
GROUTED, TYP.
HM FRAME, FULLY GROUTED
CENTERED ON CMU, TYP.
CONT. SEALANT, BOTH
SIDES, TYP.
J2A J2B
J3
J1A
BULLNOSE JAMB BLOCK, TYP.
MASONRY JAMB
ANCHOR, TYP.
GROUT JAMB BLOCK
SOLID, TYP.
PAINTED CMU WALL
WHERE INDICATED, TYP.
HM FRAME, FULLY GROUTED
CENTERED ON CMU, TYP.
CONT. SEALANT, BOTH
SIDES, TYP.
BULLNOSE JAMB BLOCK, TYP.
MASONRY JAMB
ANCHOR, TYP.
GROUT JAMB BLOCK
SOLID, TYP.
PAINTED CMU WALL
WHERE INDICATED, TYP.
CONT. SEALANT, BOTH
SIDES, TYP.
BULLNOSE JAMB BLOCK,
ONE SIDE, TYP.
MASONRY JAMB
ANCHOR, TYP.
GROUT JAMB BLOCK
SOLID, TYP.
PAINTED CMU WALL
WHERE INDICATED, TYP.
HM FRAME, FULLY GROUTED, TYP.
FRAME FLUSH WITH CORRIDOR
SIDE OF WALL.
7 5/8" 9 5/8"
7 5/8"
1'-5"
3 5/8" 1 3/4" 2" 9 5/8"
1'-5"
BRICK VENEER, TYP.
AIR SPACE, TYP.
RIGID INSULATION, TYP.
CONT. WEATHER RESISTIVE
BARRIER, TYP.
HM FRAME, FULLY
GROUTED, TYP.
CONT. SEALANT,
BOTH SIDES, TYP.
BULLNOSE JAMB
BLOCK, TYP.
MASONRY JAMB
ANCHOR, TYP.
GROUT JAMB
BLOCK SOLID, TYP.
PAINTED CMU WALL
WHERE INDICATED, TYP.
H4
HM FRAME, FULLY GROUTED,
CENTERED ON CMU, TYP.
CONT. SEALANT BOTH
SIDES, TYP.
PRECAST LINTEL PAINTED
WITH HPC-1, TYP.
5 5/8" 2 1/2" 5/8"
PAINTED CMU WALL
WHERE INDICATED, TYP.
HM FRAME, FULLY GROUTED
CENTERED ON CMU, TYP.
CONT. SEALANT, BOTH
SIDES, TYP.
J4
CMU JAMB BLOCK, TYP.
MASONRY JAMB
ANCHOR, TYP.
GROUT JAMB BLOCK
SOLID, TYP.
PAINTED CMU WALL
WHERE INDICATED, TYP.
5 5/8" 2 1/2"
5/8"
GWB J BEAD, TYP.
GWB CORNER BEAD, TYP.
BOX STUD HEADER, TYP.
METAL STUD, TYP.
GWB, TYP.
8 3/4"
8 3/4"
GWB J BEAD, TYP.
GWB CORNERBEAD, TYP.
METAL STUD, TYP.
GWB, TYP.
H1B
3 5/8" 1 3/4" 2" 7 5/8"
5/8"
BRICK VENEER, TYP.
AIR SPACE, TYP.
RIGID INSULATION, TYP.
CONT. WEATHER RESISTIVE
BARRIER, TYP.
PRE-FINISHED METAL DRIP
EDGE WITH FLEXIBLE
THROUGH WALL METAL
FLASHING, TYP.
CAVITY LINTEL PAINTED
WITH HPC-1 WHERE
EXPOSED, TYP.
PAINTED CMU WALL, TYP.
MASONRY BOND BEAM, TYP.
CONT. SEALANT BOTH
SIDES, TYP.
HM FRAME, FULLY
GROUTED, TYP.
J1B
1'-3"
3 5/8" 1 3/4" 2" 7 5/8"
BRICK VENEER, TYP.
AIR SPACE, TYP.
RIGID INSULATION, TYP.
CONT. WEATHER RESISTIVE
BARRIER, TYP.
HM FRAME, FULLY
GROUTED, TYP.
CONT. SEALANT,
BOTH SIDES, TYP.
BULLNOSE JAMB BLOCK,
ONE SIDE, TYP.
MASONRY JAMB
ANCHOR, TYP.
GROUT JAMB
BLOCK SOLID, TYP.
PAINTED CMU WALL
WHERE INDICATED, TYP.
1'-3"
SLOPE
1/2"
WALL LINE BEYOND
EXPANSION MATERIAL, TYP.
GROUT AIR CAVITY SOLID
BELOW GRADE, TYP.
EXTEND CAVITY INSULATION
BELOW GRADE, TYP.
S1
2'-0" SMOOTH DOWEL GREASED
ONE END @16" O.C. FROM CENTER
OF OPENING, TYP.
FLOOR FINISH, SEE FINISH PLANS
THERMALLY BROKEN, ADA
ACCESSIBLE ALUMINUM THRESHOLD.
SET IN FULL BED OF SEALANT, TYP.
HOLLOW METAL DOOR, TYP.
PRECAST LINTEL, TYP.
PRECAST LINTEL, TYP.
CORRIDORROOM
LIQUID TIGHT SEAL
AROUND PERIMETER OF
ROOM, TYP.
SEALED CONCRETE, TYP. SEALED CONCRETE, TYP.
DOOR PANEL, TYP.
WALL BEYOND
CAST-IN-PLACE
CONCRETE CURB, TYP.
4"
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
MARK DATE DESCRIPTION
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
PROJECT No.:
DATE:
SHEET _____ OF _____
DRAWING TITLE:
SHEET NUMBER:BUILDING NUMBER:
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
OR APPROVED BY ME, AND THAT I AM A DULY LICENSED
PROFESSIONAL ARCHITECT UNDER THE LAWS OF THE STATE OF
MARYLAND.
LICENSE NUMBER: #15505
EXPIRATION DATE: 8-18-2026
ARCHITECTURE + MASTER PLANNING
MWS PROJECT No: 23-082
CONSULTANTS:
/6
/2
:4 :4
P
M
PJ-610-230-001
03/05/2026
DOOR DETAILS
A601
BARRACK J
COMMUNICATION ROOM
& GARAGE
610 TAYLOR AVENUE
ANNAPOLIS, MARYLAND 21401
100% CONSTRUCTION
DOCUMENTS
GLC 09/12/2025
DSO
GENERAL DOOR NOTES
1 CONTRACTOR SHALL FIELD VERIFY ALL EXISTING OPENINGS/MODIFIED OPENINGS PRIOR TO FABRICATION
OF DOORS AND FRAMES.
2 DETAILS MAY VARY AT EACH DOOR. VERIFY EACH CONDITION IN FIELD.
3 SEE PARTITION SCHEDULE, FLOOR PLAN, AND STRUCTURAL DRAWINGS FOR CONSTRUCTION OF WALLS
AND PARTITIONS.
4 NEW FRAMES IN EXISTING OPENINGS SHALL RECEIVE COUNTER SUNK MASONRY EXPANSION JAMB
ANCHORS, 1/2" DIAMETER, IN LIEU OF MASONRY WIRE JAMB ANCHORS.
5 ALL DOORS SHALL BE SET WITHIN OPENINGS TO ENSURE ADA APPROACH COMPLIANCE AS INDICATED
ON SHEET G010.
1 1/2" = 1'-0"
DOOR DETAILS
GENERAL OPENING NOTES
1 CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS PRIOR TO FABRICATION OF DOORS, WINDOWS, STOREFRONT, ETC.
2 ALL FLASHING OVER EXTERIOR WINDOW AND DOOR OPENINGS TO EXTEND 8" BEYOND OPENING AND
TERMINATE ON BOTH SIDES WITH 2" HIGH DAM.
3 CONTRACTOR TO COORDINATE REQUIRED TOLERANCES IN ALL DIMENSIONS NEEDED TO MANUFACTURE
AND INSTALL WINDOW/STOREFRONT.
4 CONTINUOUSLY SEAL ALL SIDES OF WINDOW AND STOREFRONT FRAMES ABUTTING DISSIMILAR MATERIALS AT HEADS, JAMBS, AND SILLS; COORDINATE WITH MANUFACTURER FOR WEEP LOCATION.
1 1/2" = 1'-0"
RAISED SILL DETAIL
NO. DESCRIPTION DATE
146064
WH1
3 5/8" 1 3/4" 2" 9 5/8"
5/8"
BRICK VENEER, TYP.
AIR SPACE, TYP.
RIGID INSULATION, TYP.
CONT. WEATHER RESISTIVE
BARRIER, TYP.
PRE-FINISHED METAL DRIP
EDGE WITH FLEXIBLE
THROUGH WALL METAL
FLASHING, TYP.
LINTEL PAINTED WITH HPC-1
WHERE EXPOSED, TYP.
PAINTED CMU WALL, TYP.
CONT. SEALANT, TYP.
WJ1
1'-5"
3 5/8" 1 3/4" 2" 9 5/8"
1'-5"
BRICK VENEER, TYP.
AIR SPACE, TYP.
RIGID INSULATION, TYP.
CONT. WEATHER RESISTIVE
BARRIER, TYP.
CONT. SEALANT, TYP.
BULLNOSE JAMB
BLOCK, TYP.
GROUT JAMB
BLOCK SOLID, TYP.
PAINTED CMU WALL
WHERE INDICATED, TYP.
THERMALLY BROKEN
ALUMINUM STOREFRONT, TYP.
GLAZING AS SCHEDULED, TYP.
WALL BEYOND, TYP.
CONT. SEALANT WITH
BACKER ROD, TYP.
CONT. SEALANT WITH
BACKER ROD, TYP.
THERMALLY BROKEN ALUMINUM
STOREFRONT, TYP.
EXPANSION FOAM, TYP.
GLAZING, AS
SCHEDULED, TYP.
1"
SILL BELOW TO EXTEND
PAST FACE OF BLOCK, TYP.
BRICK ROWLOCK
COURSE BELOW, TYP.
BRICK ROWLOCK COURSE, TYP.
THERMALLY BROKEN ALUMINUM
STOREFRONT, TYP.
WALL BEYOND
SEALANT, TYP.
3/4" QUARTZ SILL WITH
1/8" EASED EDGE, TYP.
CONT. SEALANT WITH
BACKER ROD, TYP.
VERTICAL WEEPS @ 16" O.C., TYP.
CONT. SILL PAN FLASHING
WITH END DAMS & WEEPS, TYP.
1"
EXPANSION FOAM, TYP.
PAINTED CMU
WALL, TYP.
BRICK VENEER, TYP.
AIR SPACE, TYP.
RIGID INSULATION, TYP.
CONTINUOUS WEATHER
RESISTIVE BARRIER, TYP.
WH2
PAINTED CMU WALL, TYP.
LINTEL PAINTED WITH HPC-1
WHERE EXPOSED, TYP.
CONT. SEALANT,
BOTH SIDES, TYP.
ALUMINUM
STOREFRONT, TYP.
GLAZING, AS
SCHEDULED, TYP.
PAINTED CMU WALL, TYP.
CONT. SEALANT,
BOTH SIDES, TYP.
ALUMINUM
STOREFRONT, TYP.
GLAZING, AS
SCHEDULED, TYP.
WALL BEYOND
WJ2
BULLNOSE JAMB
BLOCK, TYP.
PAINTED CMU WALL, TYP.
CONT. SEALANT,
BOTH SIDES, TYP.
ALUMINUM
STOREFRONT, TYP.
GLAZING, AS
SCHEDULED, TYP.
WS2
BULLNOSE SILL
BLOCK, TYP.
WS1
3 5/8" 1 3/4" 2" 9 5/8"
1'-5"
7 5/8"
7 5/8"
7 5/8"
MASONRY BOND BEAM, TYP.
WH3
5/8" 6" 5/8"
7 1/4"
GWB, BOTH SIDES, TYP.
METAL STUD, TYP.
WOOD SHIM, TYP.
SEALANT, BOTH
SIDES, TYP.
ALUMINUM
STOREFRONT, TYP.
GLAZING AS
SCHEDULED
BOX STUD HEADER, TYP.
GLAZING AS
SCHEDULED
SEALANT, BOTH
SIDES, TYP.
WOOD SHIM, TYP.
METAL STUD, TYP.
GWB, BOTH SIDES, TYP.
WS3
7 1/4"
5/8" 6" 5/8"
WJ3
GWB, BOTH SIDES, TYP.
METAL STUD, TYP.
WOOD SHIM, TYP.
SEALANT, BOTH
SIDES, TYP.
ALUMINUM
STOREFRONT, TYP.
GLAZING AS
SCHEDULED
5/8" 6" 5/8" 7 1/4"
RETURN GWB TO
FRAME, TYP.
RETURN GWB TO
FRAME, TYP.
WJ4
3 5/8" 1 3/4" 2" 9 5/8"
1'-5"
BRICK VENEER, TYP.
AIR SPACE, TYP.
RIGID INSULATION, TYP.
CONT. WEATHER RESISTIVE
BARRIER, TYP.
CONT. SEALANT, TYP.
BULLNOSE JAMB
BLOCK, TYP.
GROUT JAMB
BLOCK SOLID, TYP.
PAINTED CMU WALL
WHERE INDICATED, TYP.
CONT. SEALANT WITH
BACKER ROD, TYP.
THERMALLY BROKEN ALUMINUM
STOREFRONT, TYP.
EXPANSION FOAM, TYP.
GLAZING, AS
SCHEDULED, TYP.
SOLID BLOCK BULLNOSE
SILL BELOW, TYP.
BRICK ROWLOCK
COURSE BELOW, TYP.
BRICK ROWLOCK COURSE, TYP.
THERMALLY BROKEN ALUMINUM
STOREFRONT, TYP.
WALL BEYOND
SEALANT, TYP.
SOLID BLOCK BULLNOSE
SILL, TYP.
CONT. SEALANT WITH
BACKER ROD, TYP.
VERTICAL WEEPS @ 16" O.C., TYP.
CONT. SILL PAN FLASHING
WITH END DAMS & WEEPS, TYP.
PAINTED CMU
WALL, TYP.
BRICK VENEER, TYP.
AIR SPACE, TYP.
RIGID INSULATION, TYP.
CONTINUOUS WEATHER
RESISTIVE BARRIER, TYP.
WS4
3 5/8" 1 3/4" 2" 9 5/8"
1'-5"
ALUMINUM
STOREFRONT, TYP.
3' -4
4'
-0
4'-0"
2" 3'-8" 2"
2" 3'
-8
2"
FLOOR LEVEL
W2
2" 2'-9" 2" 2'-9" 2"
6'-0"
2" 3'
-8
2" 3'
-4
GL1GL4 GL4
W1 W3
2" 3'
-1 0"
2"
GL1 4'
-2
2'
-1 0"
2" 4'-2" 2"
4'-6"
6' -8
2'
-4
GL4 GL4
6' -8
2"
2' -0
2"
2" 1'-5" 2" 1'-5" 2"
3'-4"
W4
SCHEDULE - WINDOWS
TYPE MARK OPERATION
SIZE
SILL HEIGHT HEAD JAMB SILL REMARKSWIDTH HEIGHT
W1 FIXED 6'-0" 4'-0" 3'-4" WH1 WJ1 WS1
W2 FIXED 4'-0" 4'-0" 3'-4" WH2 WJ2 WS2
W3 FIXED 4'-6" 4'-2" 2'-10" WH3 WJ3 WS3
W4 FIXED 3'-4" 2'-4" 6'-8" WH1 WJ4 WS4
1/2" = 1'-0"
WINDOW TYPES
1 1/2" = 1'-0"
WINDOW DETAILS
ALL DRAWINGS ARE PROTECTED BY FEDERAL COPYRIGHT BY MANNS WOODWARD STUDIOS, INC. AND CAN NOT BE REPRODUCED OR MODIFIED IN ANY MANNER WITHOUT WRITTEN PERMISSION. DOCUMENTS MAY NOT BE USED IN PART OR WHOLE TO DEVELOP THE DESIGN OF ANOTHER BUILDING WITHOUT EXPRESS WRITTEN PERMISSION BY MANNS WOODWARD STUDIOS.
MARK DATE DESCRIPTION
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
PROJECT No.:
DATE:
SHEET _____ OF _____
DRAWING TITLE:
SHEET NUMBER:BUILDING NUMBER:
410-344-1460
INFO@MWSARCH.COM
WWW.MWSARCH.COM
OR APPROVED BY ME, AND THAT I AM A DULY LICENSED
PROFESSIONAL ARCHITECT UNDER THE LAWS OF THE STATE OF
MARYLAND.
LICENSE NUMBER: #15505
EXPIRATION DATE: 8-18-2026
ARCHITECTURE + MASTER PLANNING
MWS PROJECT No: 23-082
CONSULTANTS:
/6
/2
:4 :4
P
M
PJ-610-230-001
03/05/2026
WINDOW SCHEDULE &
DETAILS
A602
BARRACK J
COMMUNICATION ROOM
& GARAGE
610 TAYLOR AVENUE
ANNAPOLIS, MARYLAND 21401
100% CONSTRUCTION
DOCUMENTS
GLC 09/12/2025
DSO
GENERAL OPENING NOTES
1 CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS PRIOR TO FABRICATION OF DOORS, WINDOWS, STOREFRONT, ETC.
2 ALL FLASHING OVER EXTERIOR WINDOW AND DOOR OPENINGS TO EXTEND 8" BEYOND OPENING AND
TERMINATE ON BOTH SIDES WITH 2" HIGH DAM.
3 CONTRACTOR TO COORDINATE REQUIRED TOLERANCES IN ALL DIMENSIONS NEEDED TO MANUFACTURE
AND INSTALL WINDOW/STOREFRONT.
4 CONTINUOUSLY SEAL ALL SIDES OF WINDOW AND STOREFRONT FRAMES ABUTTING DISSIMILAR MATERIALS AT HEADS, JAMBS, AND SILLS; COORDINATE WITH MANUFACTURER FOR WEEP LOCATION.
SCHEDULE - GLAZING
MARK DESCRIPTION COMMENTS
GL1 CLEAR TEMPERED GLASS
GL2 INSULATED, CLEAR GLAZING
GL3 LEVEL 8 BALLISTIC GLAZING
GL4 EXTERIOR, LOW-E, INSULATED SAFETY GLAZING
NO. DESCRIPTION DATE
146065
HW SET # DOOR # QTY ITEM DESCRIPTION COMMENTS
SET 01
Doors: 104A, 104B, 114A, 116A
1 Continuous Geared Hinge
1 Electrified Strike
1 Mortise Exit Device
1 Surface Mounted Closer
1 Perimeter Gasketing
1 Door Sweep with Drip Cap
1 Threshold
Storeroom Function (ANSI F07)
Heavy Duty Parallel Arm
Secure Exterior Entry Door - Single Leaf
ADA Accessible
1 Position Switch
1 Card Reader with Keypad (Pull Side)
Coordinate with access control contractor
Note: Contractor shall provide all wire harnesses, power supplies, transformers, wiring, junction boxes, card readers, strikes, strike plates, miscellaneous mounting hardware, and other such items for the proper and complete operation and installation of the doors/door hardware.
Note: Contractor shall coordinate voltages and other electrical requirements with complete access control system and electrified hardware systems.
OPERATION DESCRIPTION: Presentation of credentials to proximity sensor (card reader) and input of key code shall release electric strike to allow entry from pull side of door. Panic bar on push side of door shall retract latch at all times providing free egress from space. Electrified strike shall return to locked state automatically. Electrified strike shall be fail secure keeping door locked in the event of a power outage.
SET 03
Doors: 107A, 115A
3 Butt Hinge
1 Electrified Strike
1 Mortise Lockset
1 Surface Mounted Closer
1 Perimeter Gasketing
1 Wall Stop
Office Function (ANSI F04)
Heavy Duty Standard Arm with Hold Open
Secure Interior Door - Single Leaf
1 Position Switch
1 Card Reader (Push Side)
Coordinate with access control contractor
Note: Contractor shall provide all wire harnesses, power supplies, transformers, wiring, junction boxes, card readers, strikes, strike plates, miscellaneous mounting hardware, and other such items for the proper and complete operation and installation of the doors/door hardware.
Note: Contractor shall coordinate voltages and other electrical requirements with complete access control system and electrified hardware systems.
OPERATION DESCRIPTION: Presentation of credentials to proximity sensor (card reader) shall release electric strike to allow entry from push side of door.
Lever on pull side of door shall retract latch at all times providing free egress from space. Electrified strike shall return to locked state automatically.
Electrified strike shall be fail secure keeping door locked in the event of a power outage.
SET 05
Doors: 101A, 102A
3 Butt Hinge
1 Electrified Strike
1 Mortise Lockset
1 Surface Mounted Closer
Office Function (ANSI F04)
Heavy Duty Standard Arm with Hold Open
Secure Interior Door - Single Leaf
1 Position Switch
1 Card Reader (Push Side)
Coordinate with access control contractor
Note: Contractor shall provide all wire harnesses, power supplies, transformers, wiring, junction boxes, card readers, strikes, strike plates, miscellaneous mounting hardware, and other such items for the proper and complete operation and installation of the doors/door hardware.
Note: Contractor shall coordinate voltages and other electrical requirements with complete access control system and electrified hardware systems.
OPERATION DESCRIPTION: Presentation of credentials to proximity sensor (card reader) shall release electric strike to allow entry from push side of door.
Lever on pull side of door shall retract latch at all times providing free egress from space. Electrified strike shall return to locked state automatically.
Electrified strike shall be fail secure keeping door locked in the event of a power outage.
SET 06
Doors: 106A
3 Butt Hinge
1 Mortise Lockset
1 Surface Mounted Closer
Perimeter Gasketing
1 Wall Stop
Privacy Function (ANSI F19) with 2-sided indicator trim
Heavy Duty Standard Arm
Interior Door with Occupancy Indicator - Single Leaf
2 Kickplates 1-1/2" LDW
SET 07
Doors: 109A
3 Butt Hinge
1 Mortise Latchset
Door Silencers
Passage Function (ANSI F01)
Interior Storage Door - Single Leaf
SET 08
Doors: 108A
3 Butt Hinge
1 Mortise Lockset
1 Position Switch
Classroom Function (ANSI F05)
Secure Interior Door - Single Leaf
1 Electrified Strike
1 Surface Mounted Closer Heavy Duty Parallel Arm
1 Card Reader (Pull Side)
Note: Contractor shall provide all wire harnesses, power supplies, transformers, wiring, junction boxes, card readers, strikes, strike plates, miscellaneous mounting hardware, and other such items for the proper and complete operation and installation of the doors/door hardware.
Note: Contractor shall coordinate voltages and other electrical requirements with complete access control system and electrified hardware systems.
OPERATION DESCRIPTION: Presentation of credentials to proximity sensor (card reader) shall release electric strike to allow entry from pull side of door. Lever on push side of door shall retract latch at all times providing free egress from space. Electrified strike shall return to locked state automatically. Electrified strike shall be fail safe keeping door unlocked in the event of a power outage.
SET 09
Doors: 112A
3 Butt Hinge
1 Mortise Latchset
1 Wall Stop
Passage Function (ANSI F01)
Interior Door - Single Leaf
SET 10
Doors: 103B
3 Butt Hinge
1 Mortise Lockset
Perimeter Gasketing
1 Wall Stop
Secure Interior Door - Single Leaf
1 Electrified Strike
1 Surface Mounted Closer Heavy Duty Standard Arm
1 Position Switch
1 Card Reader with Keypad (Push Side)
SET 02
Doors: 103A
1 Continuous Geared Hinge
1 Electrified Strike
1 Mortise Lockset
1 Surface Mounted Closer
1 Perimeter Gasketing
1 Door Sweep with Drip Cap
1 Threshold
Storeroom Function (ANSI F07)
Heavy Duty Parallel Arm
Secure Exterior Entry Door - Single Leaf
ADA Accessible
1 Position Switch
1 Card Reader (Push Side)
Note: Contractor shall provide all wire harnesses, power supplies, transformers, wiring, junction boxes, card readers, strikes, strike plates, miscellaneous mounting hardware, and other such items for the proper and complete operation and installation of the doors/door hardware.
Note: Contractor shall coordinate voltages and other electrical requirements with complete access control system and electrified hardware systems.
OPERATION DESCRIPTION: Presentation of credentials to proximity sensor (card reader) shall release electric strike to allow entry from pull side of door.
Lever on push side of door shall retract latch at all times providing free egress from space. Electrified strike shall return to locked state automatically.
Electrified strike shall be fail secure keeping door locked in the event of a power outage.
SET 04
Doors: 114B
1 Continuous Geared Hinge
1 Electrified Strike
1 Mortise Lockset
1 Surface Mounted Closer
1 Perimeter Gasketing
1 Wall Stop
Institution (ML2032, ANSI F30)
Heavy Duty Parallel Arm
Secure Interior Door - Single Leaf
1 Position Switch
1 Card Reader (Push Side)
Note: Contractor shall provide all wire harnesses, power supplies, transformers, wiring, junction boxes, card readers, strikes, strike plates, miscellaneous mounting hardware, and other such items for the proper and complete operation and installation of the doors/door hardware.
Note: Contractor shall coordinate voltages and other electrical requirements with complete access control system and electrified hardware systems.
1 Automatic Door Bottom
OPERATION DESCRIPTION: Presentation of credentials to proximity sensor (card reader and/or card reader and keypad) shall release electric strike to allow ingress from push and pull sides of door. Electrified strike shall return to locked state automatically. Electrified strike shall be fail secure keeping door locked in the event of a power outage.
1 Perimeter Gasketing
OPERATION DESCRIPTION: Latchbolt by grip either side unless outside grip locked by thumbturn. Deadbolt by thumbturn grip inside or by emergency release tool outside. Inside grip simultaneously retracts latchbolt and deadbolt and unlocks outside grip.
OPERATION DESCRIPTION: Actuation of grip retracts latch and allowed for free egress from both the push and pull side. Strike is never locked.
Door Silencers
Door Silencers
SET 11
Doors: 105A
3 Butt Hinge
1 Mortise Lockset
1 Wall Stop
Storefroom Function (ANSI F07)
Secure Interior Door - Single Leaf
1 Electrified Strike
1 Surface Mounted Closer Heavy Duty Standard Arm
1 Position Switch
1 Card Reader (Pull Side)
Note: Contractor shall provide all wire…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .