This is an architectural drawing document for the Virgil Darnell Hawkins Community Center project in Okahumpka, Florida, prepared by MAJ Architecture + Design for the Okahumpka Community Club, Inc. The drawing sheet (A802) provides a comprehensive window schedule and installation details for the single-story Concrete Masonry Unit facility. The specification includes four window types: W1 single-hung vinyl windows measuring 5'-2½" by 4'-8½"; W2 fixed vinyl windows at 3'-11½" by 1'-11½"; W3 sliding vinyl windows at 4'-11½" by 2'-11½"; and W4 fixed vinyl windows at 1'-10½" by 4'-6½". All windows are specified as white vinyl frames with Low-E glazing and require Florida product approval. The document contains detailed exterior sill, jamb, and head installation drawings at 3" = 1'-0" scale, with specifications for fiber cement siding, transition membranes, flashing tape, backer rod application, and sealant requirements. The drawing references structural drawings for lintels and wall type details for interior finishes, with provisions for field dimension verification before fabrication.
The window specifications mandate a maximum U-factor of 0.40 and Solar Heat Gain Coefficient of 0.25 for all exterior glazing. All glazing must be Low-E glass and undergo field verification of dimensions before fabrication. The drawing set was updated through multiple phases, with the bid set revision dated July 29, 2025. Installation details include specific requirements for interior backer rod and sealant application between fenestration frames and membrane flashing, drainage gap specifications of 3/8" minimum to 1/2" maximum without sealing, and gasketed stainless steel fasteners at 16" on-center spacing. The document is part of the comprehensive bid documents for Phase 2 construction and reflects the project's compliance with applicable building codes as certified by the architectural firm's professional seal and judgment.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W2
S E E S
C H
E D
U L E
SEE SCHEDULE
ROUGH OPENING
W1 W3 W4
S E E S
C H
E D
U L E
R O
U G
H O
P E N
IN
G
SEE SCHEDULE
ROUGH OPENING
S E E S
C H
E D
U L E
R O
U G
H O
P E N
IN
G
S E E S
C H
E D
U L E
R O
U G
H O
P E N
IN
G
S E E S
C H
E D
U L E
SEE SCHEDULE
ROUGH OPENING
S E E S
C H
E D
U L E
S E E S
C H
E D
U L E
R O
U G
H O
P E N
IN
G
SEE SCHEDULE
ROUGH OPENING
INTERIOR BACKER ROD AND
SEALANT TO BE APPLIED
BETWEEN FENESTRATION
FRAME AND MEMBRANE
FLASHING AT R.O., ALL EXTENTS
PAINTER'S CAULKING (NOT
FOR AIR OR WATER BARRIER)
TRANSITION MEMBRANE
WRAPS OPENING
WINDOW AS
SCHEDULED
FIBER CEMENT FLAT PANEL OR
LAP SIDING (SEE ELEVATIONS
FOR FINISH & COLOR)
LEAVE 3/8" MIN.-1/2"
MAX. GAP; APPLY BACKER
ROD & SEALANT
4/4 FIBER CEMENT TRIM
SEALANT
SEGMENTED SEALANT UNDER
NAILING FIN (SEE NOTE)
SEE STRUCTURAL DWGS
FOR LINTEL
2x WOOD FRAMING
INTERIOR FINISH
(SEE WALL TYPE
DETAILS)
CORNER BEAD
SEE SCHEDULES AND/OR
INTERIORS DWGS FOR
INTERIOR FINISHES
REINF CMU FILL CELL (SEE
STRUCTURAL DWGS)
WINDOW AS SCHEDULED
LEAVE 3/8" MIN.-1/2" MAX. GAP;
APPLY BACKER ROD & SEALANT
FIBER CEMENT LAP SIDING
(SEE ELEVATIONS FOR
FINISH & COLOR)
TRANSITION MEMBRANE WRAPS
OPENING
CAULKING
4/4 FIBER CEMENT TRIM
SEALANT UNDER NAILING FIN
2x WOOD FRAMING
CORNER BEAD
SEALANT
SEE STRUCTURAL
DWGS FOR LINTEL
6" FLASHING TAPE OVER NAILING FIN AT HEAD
FIBER CEMENT LAP SIDING (SEE
ELEVATIONS FOR FINISH & COLOR)
SEALANT
PAINTED ALUMINUM FLASHING
THRU-WALL FLASHING OVER METAL
BASE FLASHING
PROVIDE END DAMS AT HEAD FLASHINGS;
LEAVE 3/8" MIN.-1/2" MAX. DRAINAGE GAP;
DO NOT SEAL GAP
SEALANT UNDER NAILING FIN
INTERIOR FINISH
(SEE WALL TYPE
DETAILS)
CORNER BEAD
CAULK
INTERIOR BACKER ROD AND
SEALANT TO BE APPLIED
BETWEEN FENESTRATION
FRAME AND MEMBRANE
FLASHING AT R.O.
FLASHING TAPE
AROUND OPENING
2x WOOD FRAMING
4/4 FIBER CEMENT TRIM
GASKETED S.S. FASTENER @ 16" O.C.
SEALANT
TERM BAR, SEAL TOP TO AWB
WINDOW SCHEDULE
TYPE DESCRIPTION WIDTH HEIGHT
ROUGH OPENING SILL
HEIGHT
DETAILS
FRAME TYPE GLAZING TYPE COMMENTS
WIDTH HEIGHT HEAD JAMB SILL
W1 SINGLE HUNG 5'-2 1/2" 4'-8 1/2" 5'-4" 4'-8" 2'-8" 3/A803 2/A803 1/A803 VINYL LOW-E
WHITE, MUST HAVE A FL
PRODUCT APPROVAL.
W2 FIXED 3'-11 1/2" 1'-11 1/2" 4'-0" 2'-0" 7'-4" 3/A803 2/A803 1/A803 VINYL LOW-E
WHITE, MUST HAVE A FL
PRODUCT APPROVAL.
W3 SLIDING 4'-11 1/2" 2'-11 1/2" 5'-0" 3'-0" 3'-4" 3/A803 2/A803 1/A803 VINYL LOW-E
WHITE, MUST HAVE A FL
PRODUCT APPROVAL.
W4 FIXED 1'-10 1/2" 4'-6 1/2" 2'-0" 4'-8" 2'-8" 3/A803 2/A803 1/A803 VINYL LOW-E
WHITE, MUST HAVE A FL
PRODUCT APPROVAL.
WINDOW LEGEND
WINDOW NOTES
# NOTE REV
1 FIELD VERIFY ALL DIMENSIONS.
2 ALL GLAZING SHALL BE LOW-E GLASS UNO.
3 ALL EXTERIOR GLAZING TO HAVE A MAXIMUM
U-FACTOR OF 0.40 AND SHGC OF 0.25.
4 FIELD VERIFY ALL DIMENSIONS BEFORE
FABRICATION.
T H
E S
E D
R A
W
IN
G S
A R
E T
H E
P R
O P
E R
T Y
O F
M A
J A
R C
H
IT
E C
T U
R E
D
E S
IG
N
A N
D A
R E
I S
S U
E D
O N
L Y
F O
R T
H E
U S
E O
N T
H E
S P
E C
IF
IC
P R
O J E
C T
I N
D
IC
A T
E D
O N
T H
IS
D
O C
U M
E N
T A
N Y
R E
P R
O D
U C
T
IO
N R
E V
IS
IO
N O
R M
O D
IF
IC
A T
IO
N
O F
T H
E S
E D
O C
U M
E N
T S
W
IT
H O
U T
T H
E W
R
IT
T E
N C
O N
S E
N T
O F
M A
J A
R C
H
IT
E C
T U
R E
D
E S
IG
N
I S
P
R O
H
IB
IT
E
D B
Y L
A W
T H
IS
S
H E
E T
I S
X
I F
I T
D O
E S
N O
T M
E A
S U
R E
A S
S U
C H
T H
E N
T H
E D
O C
U M
E N
T H
A S
B E
E N
M O
D
IF
IE
D
A
D J U
S T
S C
A L E
A S
N E
E D
E D
A
L W
A Y
S E
N S
U R
E T
H E
U S
E O
F T
H E
L A
T E
S T
D R
A W
IN
G
S
SHEET NUMBER
To the best of our knowledge, belief and professional judgement, these plans and specifications are in compliance with the applicable building codes.
SEAL
SUBMITTALS
CONSULTANT
malcolm@majarchdesign.com
t. 813-407-0175
© copyright 2023 All Rights Reserved
ARCHITECT
CHECKED BY :
DRAWN BY :
PROJECT # :
DRAWING INFORMATION
P R
O
JE
C T
I N
F O
R M
A T
IO
N
/2
/2
:4
:2
A
M
2025 JUL 29
A802
WINDOW SCHEDULE, DETAILS &
LEGEND
BID SET
MAJ
2024-018
MAJ
V
IR
G
IL
H
A W
K
IN
S C
IR
C
L E
O K
A H
U M
P K
A F
L
V
IR
G
IL
D
H A
W K
IN
S
C O
M M
U N
IT
Y
C E
N T
E R
SCALE: 3" = 1'-0"
EXTERIOR SILL DETAIL
SCALE: 3" = 1'-0"
EXTERIOR JAMB DETAIL
SCALE: 3" = 1'-0"
EXTERIOR HEAD DETAIL
NO. DESCRIPTION DATE
1 OWNER REVIEW 2024 SEP 20
2 DESIGN DEVELOPMENT 2024 DEC 10
100% CONSTRUCTION
DOCUMENTS
2025 JAN 27
4 PERMIT SET 2025 MAY 02
5 BID SET REVISIONS 2025 JUL 29
| Sheets |
| A802 - WINDOW SCHEDULE, DETAILS & LEGEND |
File details come from the government source that posted it. Updated .