A802_-_WINDOW_SCHEDULE_DETAILS_&_LEGEND.pdf

PDF 236 KB Posted

Attached to
Virgil Darnell Hawkins Community Center
Solicitation number
VDHCC-2025
Issued by
Lake County, Orlando City, Florida

About this file

This is an architectural drawing document for the Virgil Darnell Hawkins Community Center project in Okahumpka, Florida, prepared by MAJ Architecture + Design for the Okahumpka Community Club, Inc. The drawing sheet (A802) provides a comprehensive window schedule and installation details for the single-story Concrete Masonry Unit facility. The specification includes four window types: W1 single-hung vinyl windows measuring 5'-2½" by 4'-8½"; W2 fixed vinyl windows at 3'-11½" by 1'-11½"; W3 sliding vinyl windows at 4'-11½" by 2'-11½"; and W4 fixed vinyl windows at 1'-10½" by 4'-6½". All windows are specified as white vinyl frames with Low-E glazing and require Florida product approval. The document contains detailed exterior sill, jamb, and head installation drawings at 3" = 1'-0" scale, with specifications for fiber cement siding, transition membranes, flashing tape, backer rod application, and sealant requirements. The drawing references structural drawings for lintels and wall type details for interior finishes, with provisions for field dimension verification before fabrication.

The window specifications mandate a maximum U-factor of 0.40 and Solar Heat Gain Coefficient of 0.25 for all exterior glazing. All glazing must be Low-E glass and undergo field verification of dimensions before fabrication. The drawing set was updated through multiple phases, with the bid set revision dated July 29, 2025. Installation details include specific requirements for interior backer rod and sealant application between fenestration frames and membrane flashing, drainage gap specifications of 3/8" minimum to 1/2" maximum without sealing, and gasketed stainless steel fasteners at 16" on-center spacing. The document is part of the comprehensive bid documents for Phase 2 construction and reflects the project's compliance with applicable building codes as certified by the architectural firm's professional seal and judgment.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W2

S E E S

C H

E D

U L E

SEE SCHEDULE

ROUGH OPENING

W1 W3 W4

S E E S

C H

E D

U L E

R O

U G

H O

P E N

IN

G

SEE SCHEDULE

ROUGH OPENING

S E E S

C H

E D

U L E

R O

U G

H O

P E N

IN

G

S E E S

C H

E D

U L E

R O

U G

H O

P E N

IN

G

S E E S

C H

E D

U L E

SEE SCHEDULE

ROUGH OPENING

S E E S

C H

E D

U L E

S E E S

C H

E D

U L E

R O

U G

H O

P E N

IN

G

SEE SCHEDULE

ROUGH OPENING

INTERIOR BACKER ROD AND

SEALANT TO BE APPLIED

BETWEEN FENESTRATION

FRAME AND MEMBRANE

FLASHING AT R.O., ALL EXTENTS

PAINTER'S CAULKING (NOT

FOR AIR OR WATER BARRIER)

TRANSITION MEMBRANE

WRAPS OPENING

WINDOW AS

SCHEDULED

FIBER CEMENT FLAT PANEL OR

LAP SIDING (SEE ELEVATIONS

FOR FINISH & COLOR)

LEAVE 3/8" MIN.-1/2"

MAX. GAP; APPLY BACKER

ROD & SEALANT

4/4 FIBER CEMENT TRIM

SEALANT

SEGMENTED SEALANT UNDER

NAILING FIN (SEE NOTE)

SEE STRUCTURAL DWGS

FOR LINTEL

2x WOOD FRAMING

INTERIOR FINISH

(SEE WALL TYPE

DETAILS)

CORNER BEAD

SEE SCHEDULES AND/OR

INTERIORS DWGS FOR

INTERIOR FINISHES

REINF CMU FILL CELL (SEE

STRUCTURAL DWGS)

WINDOW AS SCHEDULED

LEAVE 3/8" MIN.-1/2" MAX. GAP;

APPLY BACKER ROD & SEALANT

FIBER CEMENT LAP SIDING

(SEE ELEVATIONS FOR

FINISH & COLOR)

TRANSITION MEMBRANE WRAPS

OPENING

CAULKING

4/4 FIBER CEMENT TRIM

SEALANT UNDER NAILING FIN

2x WOOD FRAMING

CORNER BEAD

SEALANT

SEE STRUCTURAL

DWGS FOR LINTEL

6" FLASHING TAPE OVER NAILING FIN AT HEAD

FIBER CEMENT LAP SIDING (SEE

ELEVATIONS FOR FINISH & COLOR)

SEALANT

PAINTED ALUMINUM FLASHING

THRU-WALL FLASHING OVER METAL

BASE FLASHING

PROVIDE END DAMS AT HEAD FLASHINGS;

LEAVE 3/8" MIN.-1/2" MAX. DRAINAGE GAP;

DO NOT SEAL GAP

SEALANT UNDER NAILING FIN

INTERIOR FINISH

(SEE WALL TYPE

DETAILS)

CORNER BEAD

CAULK

INTERIOR BACKER ROD AND

SEALANT TO BE APPLIED

BETWEEN FENESTRATION

FRAME AND MEMBRANE

FLASHING AT R.O.

FLASHING TAPE

AROUND OPENING

2x WOOD FRAMING

4/4 FIBER CEMENT TRIM

GASKETED S.S. FASTENER @ 16" O.C.

SEALANT

TERM BAR, SEAL TOP TO AWB

WINDOW SCHEDULE

TYPE DESCRIPTION WIDTH HEIGHT

ROUGH OPENING SILL

HEIGHT

DETAILS

FRAME TYPE GLAZING TYPE COMMENTS

WIDTH HEIGHT HEAD JAMB SILL

W1 SINGLE HUNG 5'-2 1/2" 4'-8 1/2" 5'-4" 4'-8" 2'-8" 3/A803 2/A803 1/A803 VINYL LOW-E

WHITE, MUST HAVE A FL

PRODUCT APPROVAL.

W2 FIXED 3'-11 1/2" 1'-11 1/2" 4'-0" 2'-0" 7'-4" 3/A803 2/A803 1/A803 VINYL LOW-E

WHITE, MUST HAVE A FL

PRODUCT APPROVAL.

W3 SLIDING 4'-11 1/2" 2'-11 1/2" 5'-0" 3'-0" 3'-4" 3/A803 2/A803 1/A803 VINYL LOW-E

WHITE, MUST HAVE A FL

PRODUCT APPROVAL.

W4 FIXED 1'-10 1/2" 4'-6 1/2" 2'-0" 4'-8" 2'-8" 3/A803 2/A803 1/A803 VINYL LOW-E

WHITE, MUST HAVE A FL

PRODUCT APPROVAL.

WINDOW LEGEND

WINDOW NOTES

# NOTE REV

1 FIELD VERIFY ALL DIMENSIONS.

2 ALL GLAZING SHALL BE LOW-E GLASS UNO.

3 ALL EXTERIOR GLAZING TO HAVE A MAXIMUM

U-FACTOR OF 0.40 AND SHGC OF 0.25.

4 FIELD VERIFY ALL DIMENSIONS BEFORE

FABRICATION.

T H

E S

E D

R A

W

IN

G S

A R

E T

H E

P R

O P

E R

T Y

O F

M A

J A

R C

H

IT

E C

T U

R E

D

E S

IG

N

A N

D A

R E

I S

S U

E D

O N

L Y

F O

R T

H E

U S

E O

N T

H E

S P

E C

IF

IC

P R

O J E

C T

I N

D

IC

A T

E D

O N

T H

IS

D

O C

U M

E N

T A

N Y

R E

P R

O D

U C

T

IO

N R

E V

IS

IO

N O

R M

O D

IF

IC

A T

IO

N

O F

T H

E S

E D

O C

U M

E N

T S

W

IT

H O

U T

T H

E W

R

IT

T E

N C

O N

S E

N T

O F

M A

J A

R C

H

IT

E C

T U

R E

D

E S

IG

N

I S

P

R O

H

IB

IT

E

D B

Y L

A W

T H

IS

S

H E

E T

I S

X

I F

I T

D O

E S

N O

T M

E A

S U

R E

A S

S U

C H

T H

E N

T H

E D

O C

U M

E N

T H

A S

B E

E N

M O

D

IF

IE

D

A

D J U

S T

S C

A L E

A S

N E

E D

E D

A

L W

A Y

S E

N S

U R

E T

H E

U S

E O

F T

H E

L A

T E

S T

D R

A W

IN

G

S

SHEET NUMBER

To the best of our knowledge, belief and professional judgement, these plans and specifications are in compliance with the applicable building codes.

SEAL

SUBMITTALS

CONSULTANT

malcolm@majarchdesign.com

t. 813-407-0175

© copyright 2023 All Rights Reserved

ARCHITECT

CHECKED BY :

DRAWN BY :

PROJECT # :

DRAWING INFORMATION

P R

O

JE

C T

I N

F O

R M

A T

IO

N

/2

/2

:4

:2

A

M

2025 JUL 29

A802

WINDOW SCHEDULE, DETAILS &

LEGEND

BID SET

MAJ

2024-018

MAJ

V

IR

G

IL

H

A W

K

IN

S C

IR

C

L E

O K

A H

U M

P K

A F

L

V

IR

G

IL

D

H A

W K

IN

S

C O

M M

U N

IT

Y

C E

N T

E R

SCALE: 3" = 1'-0"

EXTERIOR SILL DETAIL

SCALE: 3" = 1'-0"

EXTERIOR JAMB DETAIL

SCALE: 3" = 1'-0"

EXTERIOR HEAD DETAIL

NO. DESCRIPTION DATE

1 OWNER REVIEW 2024 SEP 20

2 DESIGN DEVELOPMENT 2024 DEC 10

100% CONSTRUCTION

DOCUMENTS

2025 JAN 27

4 PERMIT SET 2025 MAY 02

5 BID SET REVISIONS 2025 JUL 29

Sheets
A802 - WINDOW SCHEDULE, DETAILS & LEGEND

File details come from the government source that posted it. Updated .