VDH_-Electrical_Permit_Sheets.pdf

PDF 5 MB Posted

Attached to
Virgil Darnell Hawkins Community Center
Solicitation number
VDHCC-2025
Issued by
Lake County, Orlando City, Florida

About this file

These documents are architectural and engineering design plans for the Virgil D. Hawkins Community Center project, located at 27908 Virgil Hawkins Circle in Okahumpka, Florida. The project is being designed by MAJ Architecture + Design and involves the construction of a new community center facility. The plans include detailed architectural drawings such as reflected ceiling plans, exterior elevations, perspective views, and electrical lighting plans. The design features a modern building with James Hardie lap siding in Panda Gray and Volcano Gray, with trim in Auburn Brown or Brevity Brown, and a charcoal standing seam roof. The building appears to have multiple sections including a main entrance, community hall, kitchen, and restrooms, with a total floor height of approximately 10 feet above finished floor.

The design specifications emphasize specific material and color selections, with a focus on durability and aesthetic consistency. The exterior will utilize James Hardie fiber cement materials with select cedarmill finish, and the trim will be either primed for painting or pre-colored. The plans are currently in the bid set stage, marked "Not for Bidding or Construction", and have gone through multiple review stages including owner review in September 2024, design development in December 2024, and are now at 100% construction documents as of January 2025. The architectural drawings include detailed notes on painting, exterior finishes, and specific installation requirements, with careful attention to color matching, material selection, and compliance with local building codes.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CEILING LEGEND

WALL SCONCE LIGHT FIXTURES

(SEE ELECTRICAL)

JAMES HARDIE - V-GROOVE PANELS

(SEE CEILING/SOFFIT SCHEDULE)

RECESSED CAN LIGHT FIXTURE

(SEE ELECTRICAL)

EXIT SIGN AND EMERGENCY LIGHT

COMBO - TYP CENTERED ABOVE DOOR

(SEE ELECTRICAL AND LIFE SAFETY)

JAMES HARDIE - HARDIE SOFFIT

(NonVented Select Cedarmill)

EXHAUST FAN

(SEE MECHANICAL)

CEILING ACCESS HATCH

GYPSUM WALL BOARD

(SEE CEILING/SOFFIT SCHEDULE)

HB.1

8'-6"

26-13

CL CL CL CL

8'-7"8'-7 1/8"8'-7 1/8"8'-7 1/8"8'-7 1/8"8'-7"

C L

E Q

E Q

/1

/1

C L

E Q

E Q

HB.3

9'-6"

/2

/2

" HB.3

9'-6"

7-62

TYP.

26-1

HB.4

9'-7 3/8"

JAMES HARDIE "V-

GROOVE" HARDIE

ARTISAN SIDING AT

SOFFIT

E Q

E Q

HB.3

9'-11 11/16"

HB.2

10'-0"

HB.2

10'-0"

HB.1

9'-11 11/16"

HB.2

9'-11 11/16"

HB.2

9'-11 11/16"

HB.1

9'-11 11/16"

HB.1

9'-11 11/16"

HB.1

8'-6"

10-18

CLCLCL

EQ EQ EQ

C L

E Q

E Q

CLCL

4'-0" 6'-7 1/4" 4'-0"

C L C L

C L

E Q

E Q

E Q

E Q

CL

EQ EQ

CL

EQ EQ

C L E Q

E Q

CL

EQ EQ

C L C L

/4

CL

EQ EQ

HB.3

9'-11 11/16"

C L E Q

E Q

C L

CL

1'-6"

CL

1'-6"

C L1

CL

1'-0"

C L 1

8-7

C L E Q

E Q

7-62

7-62

7-62

HB.4

9'-11 3/8"

HB.4

9'-7 3/8"

/4

/4

4' -0

1'-2 3/4"

C L

/8

GB.1

9'-11 3/8"

JUNCTION BOX FOR ORNATE LIGHT

FIXTURE, REFER TO ELECTRICAL

EQ EQ

EQ EQ

C L

/8

C L

T.O. BLK

+10'-0"

9-40

9-58

6-30

TYP.

6-1

LED ROPE OR

TAPE LIGHT

7 3/8"2'-10"1'-4 3/8"

4'-9 3/4"

7-76 7-76

7-76

9-9

9-9

T.O. BLK

+10'-0"

9-40

9-58

6-30

TYP.

6-1

LED ROPE OR

TAPE LIGHT

9-9

9-58 7-76

7-76

9-9

8-7

6-1

CEILING / SOFFIT SCHEDULE

# DESCRIPTION MANUFACTURER MATERIAL FINISH COMMENTS

GB.1

MONOLITHIC CEILING

(INTERIOR)

-- 5/8" GYPSUM WALL BOARD -- --

HB.1

HARDIE BOARD PANEL ON

WOOD FRAMING (INTERIOR)

JAMES HARDIE FIBER CEMENT UNPAINTED

ARTISAN SIDING -

V-GROOVE

HB.2

HARDIE BOARD PANEL ON

WOOD FRAMING (INTERIOR)

JAMES HARDIE FIBER CEMENT

SW 6192 - COASTAL

PLAIN

ARTISAN SIDING -

V-GROOVE

HB.3

HARDIE BOARD PANEL ON

WOOD FRAMING (INTERIOR)

JAMES HARDIE FIBER CEMENT

ARCHITECTURAL

BEIGE

SELECT CEDARMILL -

HARDIE PANEL

HB.4

HARDIE SOFFIT PANEL

(EXTERIOR)

JAMES HARDIE FIBER CEMENT PANDA WHITE NON-VENTED SMOOTH

RCP NOTES

# NOTE REV

1 CONTRACTOR TO PROVIDE CEILING SAMPLES

FOR OWNER APPROVAL. ALTERNATES TO BE

APPROVED BY ARCHITECT.

2 ALL CEILING HEIGHTS ARE ABOVE FINISHED

FLOOR.

3 ALL CEILINGS ARE 10'-0" AFF UNO.

4 ARCHITECTURAL CEILING PLAN SHALL GOVERN

FOR LOCATIONS OF ALL DEVICES AS SHOWN.

ENGINEERING DOCUMENTS SHALL PREVAIL

ONLY IN CASE OF SCOPE OF WORK AND

ELEMENTS OCCURRING ABOVE CEILING.

DISCREPANCIES BETWEEN ARCHITECTURAL AND

ENGINEERING DOCUMENTS MUST BE BROUGHT

TO THE ARCHITECT'S ATTENTION.

5 SINGLE LIGHT FIXTURES IN GYPSUM BOARD

CEILINGS TO BE CENTERED IN BOTH DIRECTIONS

UNO.

6 IT IS THE RESPONSIBILITY OF THE CONTRACTOR

TO COORDINATE ALL AUDIO/VISUAL

REQUIREMENTS WITH TENANT AND/OR AV

CONSULTANT.

7 LOUVERS AND PANEL FRONTS SHALL BE SPRAY

PAINTED TO MATCH ADJACENT SURFACES,

INCLUDING FACTORY FINISHED ITEMS, UNO.

BRUSH PAINTING OF THESE ITEMS WILL NOT BE

PERMITTED.

8 DO NOT LOCATE ANY JUNCTION BOXES, HVAC

BOXES, TRANSFORMERS, ETC. ABOVE HARD

CEILING AREA. ANY ITEMS ABOVE HARD CEILING

REQUIRING AN ACCESS PANEL SHALL BE

RELOCATED SO AS TO AVOID NECESSITY OF

ACCESS PANEL.

9 APPROVAL FOR ANY ADDITIONAL ACCESS

PANELS REQUIRED IN ANY CONSTRUCTION

WITHIN THIS PROJECT SHALL BE REQUESTED IN

WRITING TO THE ARCHITECT.

10 ACCESS PANELS TO BE PAINTED TO MATCH

ADJACENT CEILING FINISH UNO.

KEYNOTE LEGEND

6-1 2X4 WOOD STUD

6-30 1x8 WOOD TRIM

7-62 PRE-FINISHED GUTTER & DOWNSPOUT

7-76 LEAVE APPROPRIATE GAP; APPLY SEALANT

8-7 CEILING ACCESS HATCH

9-9 FIBER CEMENT PANEL

9-40 5/8" GYPSUM BOARD

9-58 DRYWALL CASING BEAD

10-18 PROVIDE A FIRE DEPARTMENT KNOX BOX

(WIRED TO TRIP ALARM SYSTEM) AS REQUIRED

BY LOCAL AUTHORITY - COORDINATE FINAL

LOCATION W LOCAL FIRE MARSHAL).

26-1 LIGHT FIXTURE (SEE ELECTRICAL)

26-13 EMERGENCY EXIT SIGN AND LIGHT FIXTURE

COMBO (SEE ELECTRICAL AND LIFE SAFETY)

TRUE

NORTH

T H

E S

E D

R A

W

IN

G S

A R

E T

H E

P R

O P

E R

T Y

O F

M A

J A

R C

H

IT

E C

T U

R E

D

E S

IG

N

A N

D A

R E

I S

S U

E D

O N

L Y

F O

R T

H E

U S

E O

N T

H E

S P

E C

IF

IC

P R

O J E

C T

I N

D

IC

A T

E D

O N

T H

IS

D

O C

U M

E N

T A

N Y

R E

P R

O D

U C

T

IO

N R

E V

IS

IO

N O

R M

O D

IF

IC

A T

IO

N

O F

T H

E S

E D

O C

U M

E N

T S

W

IT

H O

U T

T H

E W

R

IT

T E

N C

O N

S E

N T

O F

M A

J A

R C

H

IT

E C

T U

R E

D

E S

IG

N

I S

P

R O

H

IB

IT

E

D B

Y L

A W

T H

IS

S

H E

E T

I S

X

I F

I T

D O

E S

N O

T M

E A

S U

R E

A S

S U

C H

T H

E N

T H

E D

O C

U M

E N

T H

A S

B E

E N

M O

D

IF

IE

D

A

D J U

S T

S C

A L E

A S

N E

E D

E D

A

L W

A Y

S E

N S

U R

E T

H E

U S

E O

F T

H E

L A

T E

S T

D R

A W

IN

G

S

SHEET NUMBER

To the best of our knowledge, belief and professional judgement, these plans and specifications are in compliance with the applicable building codes.

SEAL

SUBMITTALS

CONSULTANT

malcolm@majarchdesign.com

t. 813-407-0175

© copyright 2023 All Rights Reserved

ARCHITECT

CHECKED BY :

DRAWN BY :

PROJECT # :

DRAWING INFORMATION

P R

O

JE

C T

I N

F O

R M

A T

IO

N

/2

/2

:4

:3

P M

2025 JAN 27

A111

NEW REFLECTED CEILING PLAN

NOT FOR

BIDDING OR

CONSTRUCTION

MAJ

2024-018

MAJ

V

IR

G

IL

H

A W

K

IN

S C

IR

C

L E

O K

A H

U M

P K

A , F

L

V

IR

G

IL

D

H A

W K

IN

S

C O

M M

U N

IT

Y

C E

N T

E R

NO. DESCRIPTION DATE

2 DESIGN DEVELOPMENT 2024 DEC 10

100% CONSTRUCTION

DOCUMENTS

2025 JAN 27

SCALE: 1/4" = 1'-0"

NEW REFLECTED CEILING PLAN

SCALE: 1/4" = 1'-0"

NEW REFLECTED CEILING PLAN

SCALE: 1 1/2" = 1'-0"

CEILING DETAIL - COVE LIGHTING @ ENTRY

SCALE: 1 1/2" = 1'-0"

CEILING DETAIL - COVE LIGHTING @ VAULT

SCALE: 3" = 1'-0"

CEILING ACCESS HATCH DETAIL

PERMIT SET

BID SET

LEVEL 1

+0'-0"

T.O. BLK

+10'-0"

GRADE

-1'-0"

5-58 9-5

26-1

AWNING

WINDOW

W1

W1 W1W1 W1

8-15-58 26-18-8 9-5 9-6 6-199-79-7

W4

5-58

9-5

8-8

AWNING

WINDOW

LEVEL 1

+0'-0"

T.O. BLK

+10'-0"

GRADE

-1'-0"

9-5 AWNING WINDOWS, TYP5-58

H D

H T

W2 W2 W2

9-69-7

LEVEL 1

+0'-0"

T.O. BLK

+10'-0"

GRADE

-1'-0"

W4

O V E R

A L L H

T P E R F

B C

/4

5-58 9-5 8-8

26-1

5-45

9-6 5-58 9-526-1

TYP.

6-19 5-45

W3

SLIDING WINDOW5-58 9-5 9-6

26-1

6-19

5-45

9-7

LEVEL 1

+0'-0"

T.O. BLK

+10'-0"

GRADE

-1'-0"

5-39 9-5 9-6

LEVEL 1

+0'-0"

T.O. BLK

+10'-0"

GRADE

-1'-0"

W4

5-58 26-110-18 8-88-1 9-5

9-67-62

ELEVATION NOTES

# NOTE REV

1 EXTERIOR PAINT TO INCLUDE M1 ADDITIVE TO

PREVENT MILDEW AND FUNGUS GROWTH.

2 PAINT SHALL BE SHERWIN WILLIAMS 25 YR

SUPER PAINT OR APPROVED EQ.

3 ALL METAL PAINT TO BE ENAMEL BASE.

4 GENERAL CONTRACTOR TO PROVIDE SHOP

DRAWINGS FOR ALL EXTERIOR LIGHT FIXTURES

FOR APPROVAL BY ARCHITECT AND OWNER,

PRIOR TO PURCHASE AND INSTALLATION

COMPLYING W/ APPLICABLE ADA GUIDELINES.

5 CONTRACTOR TO PAINT ALL EXPOSED PIPES,

CONDUCTS, DISCONNECTS & JUNCTION BOXES

TO MATCH ADJACENT SURFACE.

6 CONTRACTOR TO PROVIDE FOR COMPONENTS

AND CLADDING A FLORIDA PRODUCT APPROVAL

OR NOTICE OF ACCEPTANCE FROM STATE OF

FLORIDA AND SHOP DRAWINGS FOR APPROVAL

BY ARCHITECT, ENGINEER, AND COUNTY PRIOR

TO ORDERING AND CONSTRUCTION.

7 ELEVATION HEIGHTS ARE FOR REFERENCE ONLY

TO THE ARCHITECTURAL DRAWINGS. SEE CIVIL

FOR ACTUAL FLOOR HEIGHT ABOVE SEA LEVEL.

CONTACT ARCHITECT OF RECORD IF HEIGHTS

DIFFER.

8 NO SIGNAGE IS INCLUDED IN THIS PACKAGE.

SIGNAGE SHOWN FOR REFERENCE ONLY. ALL

SIGNS MUST BE PERMITTED SEPARATELY.

9 COLOR SAMPLES TO BE APPROVED BY OWNER

BEFORE APPLICATION. IF PRINTED IN COLOR,

THESE ELEVATIONS ONLY OFFER A GENERAL

REPRESENTATION OF THE SELECTED COLORS.

COLORS VIEWED ON A COMPUTER SCREEN AND

THEN PRINTED WILL VARY AND WILL NEVER BE

AN EXACT REPRESENTATION OF THE ACTUAL

PIGMENT. REFER TO MANUFACTURER PROVIDED

COLOR SAMPLES ONLY FOR FINAL APPROVAL.

10 WHERE COLOR IS SHOWN AS BEING SPECIFIC TO

ONE MANUFACTURER, AN EQUIVALENT COLOR

BY ANOTHER MANUFACTURER MAY BE

SUBMITTED FOR APPROVAL. MANUFACTURERS

AND MATERIALS SPECIFIED ARE NOT INTENDED

TO LIMIT THE SELECTION OF EQUAL COLORS

AND PERFORMANCE FROM OTHER.

11 DO NOT TRANSITION PAINT COLORS ON AN

EXTERIOR CORNER. ALL COLOR CHANGES

SHOULD BE AT INTERIOR CORNERS, UNO.

CONTACT ARCHITECT IF A CONFLICT OCCURS.

12 PAINT ALL EXPOSED EDGES OF TRIM, INCLUDING

EDGES.

13 LOUVERS AND PANEL FRONTS SHALL BE SPRAY

PAINTED TO MATCH ADJACENT SURFACES,

INCLUDING FACTORY FINISHED ITEMS, UNO.

BRUSH PAINTING OF THESE ITEMS WILL NOT BE

PERMITTED.

14 ALL EXTERIOR GLAZING TO HAVE A MAXIMUM

U-FACTOR OF 0.65 AND SHGC OF 0.25.

KEYNOTE LEGEND

5-39 METAL CANOPY

5-45 1 1/2" DIA. PAINTED STEEL PIPE RAILING

5-58 METAL STANDING SEAM

6-19 P.T. WOOD POST

7-62 PRE-FINISHED GUTTER & DOWNSPOUT

8-1 DOOR & FRAME (SEE DOOR SCHEDULE)

8-8 WINDOW (SEE WINDOW SCHEDULE)

9-5 FIBER CEMENT LAP SIDING

9-6 4/4 FIBER CEMENT TRIM - 7-1/4" WIDE

9-7 4/4 FIBER CEMENT TRIM - 5-1/2" WIDE

10-18 PROVIDE A FIRE DEPARTMENT KNOX BOX

(WIRED TO TRIP ALARM SYSTEM) AS REQUIRED

BY LOCAL AUTHORITY - COORDINATE FINAL

LOCATION W LOCAL FIRE MARSHAL).

26-1 LIGHT FIXTURE (SEE ELECTRICAL)

T H

E S

E D

R A

W

IN

G S

A R

E T

H E

P R

O P

E R

T Y

O F

M A

J A

R C

H

IT

E C

T U

R E

D

E S

IG

N

A N

D A

R E

I S

S U

E D

O N

L Y

F O

R T

H E

U S

E O

N T

H E

S P

E C

IF

IC

P R

O J E

C T

I N

D

IC

A T

E D

O N

T H

IS

D

O C

U M

E N

T A

N Y

R E

P R

O D

U C

T

IO

N R

E V

IS

IO

N O

R M

O D

IF

IC

A T

IO

N

O F

T H

E S

E D

O C

U M

E N

T S

W

IT

H O

U T

T H

E W

R

IT

T E

N C

O N

S E

N T

O F

M A

J A

R C

H

IT

E C

T U

R E

D

E S

IG

N

O

H

IB

IT

E

D B

Y L

A W

T H

IS

S

H E

E T

I S

X

I F

I T

D O

E S

N O

T M

E A

S U

R E

A S

S U

C H

T H

E N

T H

E D

O C

U M

E N

T H

A S

B E

E N

M O

D

IF

IE

D

A

D J U

S T

S C

A L E

A S

N E

E D

E D

A

L W

A Y

S E

N S

U R

E T

H E

U S

E O

F T

H E

L A

T E

S T

D R

A W

IN

G

S

SHEET NUMBER

To the best of our knowledge, belief and professional judgement, these plans and specifications are in compliance with the applicable building codes.

SEAL

SUBMITTALS

CONSULTANT

malcolm@majarchdesign.com

t. 813-407-0175

© copyright 2023 All Rights Reserved

ARCHITECT

CHECKED BY :

DRAWN BY :

PROJECT # :

DRAWING INFORMATION

P R

O

JE

C T

I N

F O

R M

A T

IO

N

/2

/2

:4

:4

P M

2025 JAN 27

A301

EXTERIOR ELEVATIONS

NOT FOR

BIDDING OR

CONSTRUCTION

MAJ

2024-018

MAJ

V

IR

G

IL

H

A W

K

IN

S C

IR

C

L E

O K

A H

U M

P K

A , F

L

V

IR

G

IL

D

H A

W K

IN

S

C O

M M

U N

IT

Y

C E

N T

E R

SCALE: 3/16" = 1'-0"

EXTERIOR ELEVATION - COMM. LEFT

SCALE: 3/16" = 1'-0"

EXTERIOR ELEVATION - COMM. HALL FRONT

SCALE: 3/16" = 1'-0"

EXTERIOR ELEVATION - COMM. HALL RIGHT

SCALE: 3/16" = 1'-0"

EXTERIOR ELEVATION - COMM. HALL REAR

SCALE: 3/16" = 1'-0"

EXETERIOR ELEVATION - KITCHEN/RESTROOMS LEFT

SCALE: 3/16" = 1'-0"

EXETERIOR ELEVATION - KITCHEN/RESTROOMS FRONT

SCALE: 3/16" = 1'-0"

EXETERIOR ELEVATION - KITCHEN/RESTROOMS RIGHT

SCALE: 3/16" = 1'-0"

EXETERIOR ELEVATION - KITCHEN/RESTROOMS REAR

NO. DESCRIPTION DATE

1 OWNER REVIEW 2024 SEP 20

2 DESIGN DEVELOPMENT 2024 DEC 10

100% CONSTRUCTION

DOCUMENTS

2025 JAN 27

SCALE: 3/16" = 1'-0"

EXTERIOR ELEVATION - MAIN ENTRY

BODY FINISHES:

JAMES HARDIE LAP SIDING:

SELECT CEDARMILL

COLOR: PANDA GRAY

5" EXPOSURE

JAMES HARDIE LAP SIDING:

SELECT CEDARMILL

COLOR: VOLCANO GRAY

7" EXPOSURE

TRIM & ACCENTS:

JAMES HARDIE 4/4 & 5/4 SMOOTH

TRIM :

COLOR: AUBURN BROWN (JAMES

HARDIE)

--OR--

(PRIMED FOR PAINT)

COLOR: BREVITY BROWN - SW 6068

JAMES HARDIE NON-VENTED

SMOOTH SOFFIT

COLOR: PANDA WHITE

JAMES HARDIE 4/4 SMOOTH TRIM

FASCIA:

COLOR: ARCTIC WHITE

STANDING SEAM ROOF

COLOR: CHARCOAL

JAMES HARDIE 4/4 & 5/4 SMOOTH

TRIM WRAP AT POST AND BEAMS:

COLOR: AUBURN BROWN (JAMES

HARDIE)

--OR--

(PRIMED FOR PAINT)

COLOR: BREVITY BROWN - SW 6068

T H

E S

E D

R A

W

IN

G S

A R

E T

H E

P R

O P

E R

T Y

O F

M A

J A

R C

H

IT

E C

T U

R E

D

E S

IG

N

A N

D A

R E

I S

S U

E D

O N

L Y

F O

R T

H E

U S

E O

N T

H E

S P

E C

IF

IC

P R

O J E

C T

I N

D

IC

A T

E D

O N

T H

IS

D

O C

U M

E N

T A

N Y

R E

P R

O D

U C

T

IO

N R

E V

IS

IO

N O

R M

O D

IF

IC

A T

IO

N

O F

T H

E S

E D

O C

U M

E N

T S

W

IT

H O

U T

T H

E W

R

IT

T E

N C

O N

S E

N T

O F

M A

J A

R C

H

IT

E C

T U

R E

D

E S

IG

N

O

H

IB

IT

E

D B

Y L

A W

T H

IS

S

H E

E T

I S

X

I F

I T

D O

E S

N O

T M

E A

S U

R E

A S

S U

C H

T H

E N

T H

E D

O C

U M

E N

T H

A S

B E

E N

M O

D

IF

IE

D

A

D J U

S T

S C

A L E

A S

N E

E D

E D

A

L W

A Y

S E

N S

U R

E T

H E

U S

E O

F T

H E

L A

T E

S T

D R

A W

IN

G

S

SHEET NUMBER

To the best of our knowledge, belief and professional judgement, these plans and specifications are in compliance with the applicable building codes.

SEAL

SUBMITTALS

CONSULTANT

malcolm@majarchdesign.com

t. 813-407-0175

© copyright 2023 All Rights Reserved

ARCHITECT

CHECKED BY :

DRAWN BY :

PROJECT # :

DRAWING INFORMATION

P R

O

JE

C T

I N

F O

R M

A T

IO

N

/2

/2

:4

:5

P M

2025 JAN 27

A305

PERSPECTIVE VIEWS

NOT FOR

BIDDING OR

CONSTRUCTION

MAJ

2024-018

MAJ

V

IR

G

IL

H

A W

K

IN

S C

IR

C

L E

O K

A H

U M

P K

A , F

L

V

IR

G

IL

D

H A

W K

IN

S

C O

M M

U N

IT

Y

C E

N T

E R

3D PERSPECTIVE - COMMUNITY CENTER EAST

3D PERSPECTIVE - COMMUNITY CENTER FRONT

NO. DESCRIPTION DATE

1 OWNER REVIEW 2024 SEP 20

2 DESIGN DEVELOPMENT 2024 DEC 10

100% CONSTRUCTION

DOCUMENTS

2025 JAN 27

SCALE:

3D PERSPECTIVE - COMMUNITY CENTER SOUTH SIDE

SCALE:

3D PERSPECTIVE - MAIN ENTRANCE

SCALE:

3D PERSPECTIVE - COMMUNITY CENTER REAR

ELECTRICAL LIGHTING PLAN

N definitive design solutions 2008 Hibiscus Ct.

Sanford, FL 32771 407-416-5155

CA #31637

Jesus Mitu Lacanilao

FL67301

02/28/2027

TH

ES

E D

R

AW

IN

G

S

AR

E

TH

E

PR

O

PE

R

TY

O F

M

AJ

A R

C H

IT

EC

TU

R

E

D

ES

IG

N

A N

D A

R E

IS

SU

ED

O

N

LY

F O

R T

H E

U

SE

O N

T H

E

SP

EC

IF

IC

P

R O

JE

C

T

IN

D

IC

AT

ED

O N

T H

IS

D

O C

U M

EN

T.

A N

Y R

EP

R

O D

U C

TI

O

N , R

EV

IS

IO

N

, O R

M O

D

IF

IC

AT

IO

N

O F

TH

ES

E D

O C

U M

EN

TS

W

IT

H O

U T

TH

E

W R

IT

TE

N C

O N

SE

N

T O

F M

AJ

A

R C

H

IT

EC

TU

R E

D

ES

IG

N

IS

PR

O

H

IB

IT

ED

B Y

LA

W

TH

IS

S H

EE

T

IS

4" X

6"

, I F

IT

D

O

ES

N O

T M

EA

SU

R E

AS

S

U C

H T

H

EN

T H

E D

O C

U M

EN

T

H

AS

B

EE

N M

O D

IF

IE

D , A

D

JU

ST

S

C

AL

E

AS

N

EE

D

ED

AL

W

AY

S

EN

SU

R

E

TH

E U

SE

O

F

TH

E

LA

TE

ST

D R

AW

IN

G S.

SHEET NUMBER

To the best of our knowledge, belief and professional judgement, these plans and specifications are in compliance with the applicable building codes.

SEAL

SUBMITTALS

CONSULTANT

malcolm@majarchdesign.com

t. 813-407-0175 © copyright 2023 All Rights Reserved

ARCHITECT

CHECKED BY :

DRAWN BY :

PROJECT # :

DRAWING INFORMATION

P R

O

JE

C T

I N

F O

R M

A T

IO

N

3/

/2

:1 9:

A

M

2024-018

VI

R G

IL

H

A W

K

IN

S C

IR

C

LE

O

K A

H U

M

PK

A , F

L

VI

R

G

IL

D . H

AW

KI

N S

C O

M M

U N

IT

Y

C

EN

TE

R

NO. DESCRIPTION DATE

JVL

JML

L I C E NS E

No.67301

STATE OF

J E

SU

S MITU LACANILAO

P R

O F

ESS I ONA L

F L O R I D A

ENG I N

E E R

E201

ELECTRICAL LIGHTING PLAN

File details come from the government source that posted it. Updated .