This document is an Ordering Data Sheet for a sealed beta reference source. The key details are:
The source is a steel disk with an active element surrounded by an aluminum ring and aluminized Mylar window. It has an overall diameter of 47 mm, active diameter of 41 mm, and height of 3.18 mm. The source activity is 100 nCi (+/- 10%) of Pm-147. The vendor must ensure the activity is less than exempt quantity per 10 CFR 30. The reported radioactivity uncertainty must not exceed 5% at 99% confidence. Surface contamination must be less than 450 pCi/100cm2. A Certificate of Calibration is required, which must be NIST-traceable and document the total activity, activity of each nuclide, uncertainty, reference time/date, gamma impurities, and source serial number.
The source will be shipped to Puget Sound Naval Shipyard. The vendor must contact the shipyard prior to shipping to provide tracking information. Changes to the technical requirements are not allowed without shipyard approval.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ORDERING DATA SHEET – GENERAL
NOUN NAME: RADIOACTIVE SOURCES
DESCRIPTION:
1 ea Sealed beta reference source in the form of a steel disk with active element surrounded by an aluminum ring with 0.9 mg/cm^2 aluminized Mylar window. Overall diameter of 47 mm; Active diameter of 41 mm; Height of 3.18 mm.
-The source activity is 100 nCi (–10%, +10%) Pm-147.
-The vendor must insure that the source activity is not greater than exempt quantity per 10 CFR 30.
-The reported radioactivity uncertainty of each nuclide shall not exceed ± 5% at the 99% confidence level.
-Surface contamination levels on the source and packing materials must be less than 450 pCi/100cm^2.
MATERIAL: N/A
MANUFACTURER/VENDOR P/N: N/A
QUANTITY: 1 each
ADDITIONAL NOTES:
CERTIFICATION
-A Certificate of Calibration is required for the source and shall be provided from the vendor that documents:
-The source shall be National Institute of Standards and Technology (NIST) traceable
-The total activity of the source
-The activity of each nuclide in the source
-The uncertainty value, reference time and date
-The activity of any gamma emitting impurities detected
-The vendor assigned source serial number
-ISO Classification
-The results and date of leakage testing
SHIPPING REQUIREMENTS
Source will be shipped by vendor to:
(N4523A) Puget Sound Naval Shipyard & IMF
1400 Farragut Avenue, Building 514
Bremerton, WA 98314-5001
Attn: C/2380.4R - R. Nicole Van Den Eijkel (360) 801-6048
POC: C/105.55 Marc Sobolesky (360) 340-4797
Prior to shipping, vendor will make voice contact via phone with Nicole Van Den Eijkel or their representative at (360) 476-
3520 with date of shipment and shipment tracking information (i.e. UPS/FEDEX tracking numbers). A phone message will not be considered voice contact.
Changes to specification or other technical requirements are not allowed without Shipyard approval via the Administrative
Contracting Officer (ACO).
JOB ORDER
991566SOUR
KEY OP
H01
KO ITEM
REV
IDN
4152VL06
IDN REV
2305.3 Form; Rev 02/2020