This document is an Ordering Data Sheet for a radioactive source. The key details are:
The source is a nine nuclide gamma calibration source in the form of a 500 ml solid epoxy matrix. The nuclide mixture includes Cd-109, Co-57, Te-123m, Cr-51, Sn-113, Sr-85, Cs-137, Y-88, and Co-60. The active volume is 500 ml with a density of 1.0 g/cc. The total source activity shall be 3.0 microcuries (-15%, +0%), and the radioactivity uncertainty for each nuclide shall not exceed 5% at the 99% confidence level. Surface contamination levels must be less than 450 pCi/100cm^2. A Certificate of Calibration from the vendor is required, which must document the NIST-traceability, nuclide activities and uncertainty, density, volume, and serial number. The source is to be shipped by the vendor to the Puget Sound Naval Shipyard.
This Ordering Data Sheet is associated with a pre-solicitation for a federal contract opportunity from the Department of the Navy Naval Supply Systems Command to procure this radioactive source. The solicitation number is N4523A-VL00.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ORDERING DATA SHEET – GENERAL
NOUN NAME: RADIOACTIVE SOURCE
DESCRIPTION:
1 ea Nine nuclide gamma calibration source in the form of 500 ml solid epoxy matrix in customer provided 500 ml bottle.
-Nuclide mixture: Cd-109, Co-57, Te-123m, Cr-51, Sn 113, Sr-85, Cs-137, Y-88, Co-60 with nuclide activity ratios selected to provide similar count rates on typical coaxial high-purity germanium detectors.
-Active volume: 500 ml
-Density of solid: 1.0 g/cc.
-Total source activity shall be 3.0 microcuries (–15%, +0%)
-The vendor must insure that the source activity is not greater than exempt quantity per 10 CFR 30.
-The reported radioactivity uncertainty of each nuclide shall not exceed ± 5% at the 99% confidence level.
-Surface contamination levels on the source and packing materials must be less than 450 pCi/100cm^2
MATERIAL: N/A
MANUFACTURER/VENDOR P/N: N/A
QUANTITY: 1 each
ADDITIONAL NOTES:
CERTIFICATION
-A Certificate of Calibration is required for the source and shall be provided from the vendor that documents:
-The source shall be National Institute of Standards and Technology (NIST) traceable
-The total activity of the source, reference time, and date
-The activity, gamma emission rate, and associated uncertainty of each nuclide
-The activity of any gamma emitting impurities detected
-Density and volume of active volume
-The vendor assigned source serial number
-ISO Classification
-The results and date of leakage testing
SHIPPING REQUIREMENTS
Source will be shipped by vendor to:
(N3999H) Puget Sound Naval Shipyard & IMF
1400 Farragut Avenue, Building 450, Door 2
Bremerton, WA 98314-5001
Attn: C/2380.4R - R. Nicole Van Den Eijkel (360) 801-6048
POC: C/105.55 Marc Sobolesky (360) 340-4797
Prior to shipping, vendor will make voice contact via phone with Nicole Van Den Eijkel or their representative at (360) 476-
3520 with date of shipment and shipment tracking information (i.e. UPS/FEDEX tracking numbers). A phone message will not be considered voice contact.
Changes to specification or other technical requirements are not allowed without Shipyard approval via the Administrative
Contracting Officer (ACO).
JOB ORDER
991566SOUR
KEY OP
H01
KO ITEM
REV
IDN
4152VL03
IDN REV
2305.3 Form; Rev 02/2020