A04_2026_Repairs_Needed_2025_Deficiency_List.docx
DOCX document 21 KB Posted
- Attached to
- GRTE FIRE SUPPRESSION/PANEL INSPECTIONS Federal contract opportunity
- Solicitation number
- 140P1426Q0099
About this file
This is a deficiency list for fire suppression and safety system repairs required at Grand Teton National Park in 2026. The document outlines maintenance and corrective work needed across multiple park facilities, including the Moran Entrance Station, Colter Bay Ranger Station, various residential quarters, the Laurence Rockefeller Preserve, and administrative buildings such as the Craig Thomas Visitor Center and Moose Headquarters. The primary work items include performing five-year internal inspections on fire suppression systems, replacing outdated or non-functional quick response sprinklers, repairing or replacing defective flow switches and alarm panels, updating pressure gauges, and addressing specific system deficiencies such as corroded components and inoperable controls.
The deficiency list identifies approximately 40 locations requiring inspection and repair work, with specific issues documented for individual facilities. Notable repairs include replacing 20-year-old quick response sprinklers at Colter Bay Ranger Station, replacing outdated sprinklers in basement areas at multiple quarters, repairing corroded and inoperable flow switches at several locations, replacing damaged controllers and power bulbs, and addressing malfunctioning alarm systems at the Tornado Alley/IT Shop and Granite Entrance Station. This list directly supports the solicitation for Grand Teton National Park's annual fire suppression system inspections, annual fire panel inspections, and 2026 repairs through the National Park Service Intermountain Region.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_1_Questions_and_Answers_0001.docx | DOCX document | |
| Amendment_1_GRTE_Fire_Suppression_and_Fire_Panel_Inspection_STATEMENT_OF_WORK_Rev_09222026_0001.docx | DOCX document | |
| Amendment_1_GRTE_Fire_Inspections_Location_Schedule_2026_Rev_09222026_0001.xlsx | XLSX spreadsheet | |
| Sol_140P1426Q0099_Amd_0001.pdf | ||
| Amendment_1_GRTE_Fire_Alarm_Points_List_Rev_09222026_0001.xlsx | XLSX spreadsheet | |
| A04_44045721_GRTE_Fire_Suppression_and_Fire_Panel_Inspection_STATEMENT_OF_WORK.docx | DOCX document | |
| B03_Teton_County_2015-5409_Rev_30_08222026.pdf | ||
| A04_44045721_GRTE_Fire_Inspections_Location_Schedule_2026.xlsx | XLSX spreadsheet | |
| Sol_140P1426Q0099.pdf | ||
| A04_44045721_GRTE_Fire_Alarm_Points_List.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2026 Repairs - Teton National Park 2025 Deficiency List
SRLC
Perform 5yr Internal Inspection Moran Entrance Station Perform 5yr Internal Inspection Replace 20yr Quick Response Sprinklers Colter Bay Ranger Station Perform 5yr Internal Inspection Colter Bay B & U Perform 5yr Internal Inspection Colter Bay Roads Perform 5yr Internal Inspection Quarters 1443 Perform 5yr Internal Inspection Test or replace QR Sprinklers 2026 Quarters 1442 Perform 5yr Internal Inspection Test or replace QR Sprinklers 2026 Quarters 1441 Perform 5yr Internal Inspection Test or replace QR Sprinklers 2026 Quarters 1434 Perform 5yr Internal Inspection Replace damaged flow switch. (inop) Quarters 1427 Perform 5yr Internal Inspection Replace outdated sprinklers in basement.
Laurence Rockefeller Preserve Add drain to fire pump test header in pump room for draining test header after pump test. Perform 5yr Internal Inspection Replace power “ON” bulb on controller Pipe packing drain to floor drain White Grass Main Cabon Gauges outdated 4 Lazy F Perform 5yr Internal Inspection Provide signage indicating Anti-Freeze has been removed and system is water… Moulton Main House Gauges outdated Quarters 1447 Perform 5yr Internal Inspection Quarters 1446 Perform 5yr Internal Inspection Quarters 1454 Gauges outdated
Bird nest on sprinkler at porch Quarters 1455 Perform 5yr Internal Inspection Quarters 1440 Perform 5yr Internal Inspection Quarters 1439 Perform 5yr Internal Inspection Test or replace QR Sprinklers Craig Thomas VC Perform 5yr Internal Inspection Quarters 188 Perform 5yr Internal Inspection Flow switch corroded and does not operate.
Quarters 187 – D Perform 5yr Internal Inspection Quarters 199 Perform 5yr Internal Inspection Quarters 200 Perform 5yr Internal Inspection Quarters 164 – B Gauge outdated Quarters 198 Perform 5yr Internal Inspection Quarters 197 Perform 5yr Internal Inspection Quarters 196 Perform 5yr Internal Inspection Quarters 195 Perform 5yr Internal Inspection Quarters 194 Perform 5yr Internal Inspection Quarters 1093 Gauge outdated Quarters 1104 Gauge outdated Quarters 1424 Perform 5yr Internal Inspection Replace outdated sprinklers in basement Quarters 1423 Perform 5yr Internal Inspection Replace outdated sprinklers in basement Quarters 1425 Perform 5yr Internal Inspection Replace outdated sprinklers in basement Quarters 1426 Perform 5yr Internal Inspection Replace outdated sprinklers in basement
Quarters 1433 Replace outdated sprinklers Moose Headquarters Perform 5yr Internal inspection Moose Woodshop Perform 5yr Internal Inspection Flow did not operate.
Tornado Alley / IT Shop Alarms did not operate. Repair alarm panel. Perform 5yr Internal Inspection Granite Entrance Station Flow switch did not operate. Flow switch appears to be damaged. Perform 5yr Internal Inspection GTA / Gym Perform 5yr Internal Inspection