This is a Scope of Work document for a County procurement involving the installation and commissioning of an air compressor system. The vendor must furnish and install a compressor unit by August 17, 2026, including mechanical assembly, connection to the existing compressed air distribution header, condensate drain line connections, and verification of all safety devices and controls. The scope encompasses factory-authorized startup and commissioning with documentation submitted within five business days of completion, operator and maintenance training for a minimum of two hours conducted by the vendor's factory-authorized technician, and delivery via lift-gate equipped truck with offloading and staging at the installation site. A critical requirement stipulates that all components must pass through a 46-inch wide doorframe without structural building modifications. The vendor must provide certified weight data at least ten business days prior to delivery and coordinate delivery access with the County five business days in advance.

The pricing structure includes all costs consolidated into a single line item covering the system, installation, training, and warranty. The vendor is responsible for all labor, tools, rigging, incidental materials, required permits, licenses, and calibration with certificates provided to the County. The County retains responsibility for electrical rough-in (conduit, disconnect, and branch circuit wiring), compressed air distribution piping beyond the outlet connection, and provision of a level, reinforced concrete or structural floor adequate for the unit weight. Warranty coverage includes 24 months for the compressor pump from acceptance and 12 months of parts and labor for the overall system. An optional extended warranty coverage for years one through five is available at an additional rate to be specified by the vendor.

View the file

Other files

File Type Posted
44A3FAEC-97F9-FAD6-B54F90D5CEDD52DA.xlsx XLSX spreadsheet
4ADC244E-B24C-BEC2-4654E43F7ACFB8A4.xlsx XLSX spreadsheet
8B00ECA9-D368-AD09-80DA20EDC1915543.pdf PDF
E99082A3-014B-96AB-48063D8559F32599.pdf PDF
C0135AC1-FF9D-F3AC-BDB7FB4697056E65.pdf PDF
39A8A9E3-F569-C6B6-B9E7BF50CFDC4F51.pdf PDF
44F2A935-093F-1234-3F0F06EFB73CE154.xlsx XLSX spreadsheet
58DCD716-9EAC-9E14-6719EE5FDA607EE3.pdf PDF
1FF81613-C943-E907-903208614AFFB273.pdf PDF
471F2B18-FADB-16E3-6A13A124C82D15B3.pdf PDF
455CA489-AF8F-CF71-6FFA3A68482AEF22.pdf PDF
76154B86-0D35-C013-E46368EB2B8F2266.pdf PDF
36771012-968A-47BA-49FB1CC4DFFFEC63.pdf PDF
B867E43E-FCA2-ABC6-686473D3D551080B.docx DOCX document
8BE169B1-0EA5-67F3-FE8D32CD74B2BC3C.pdf PDF
451D7EC8-9FAF-B01F-15E5F86D68AB3D4B.xlsx XLSX spreadsheet
48C544C3-FCC4-F4ED-99FB5E91E5744B30.pdf PDF
F13E338C-C030-4C55-2FE32EE64813CA9E.docx DOCX document
9188FC82-07E6-2A24-E7927A56369C067A.pdf PDF
471F0983-EB69-959C-3B62A289547CA11E.xlsx XLSX spreadsheet
600AF88E-C800-4399-20BE9FDE4A50714B.docx DOCX document
FAFB33F1-A49E-7354-6799AC07E5D29DA0.pdf PDF
47ADF7AD-983F-9719-2E5C720D20F03E5A.xlsx XLSX spreadsheet
8BD45E27-AD3D-2A81-9DC34421F6415618.pdf PDF
8CFF3838-EA7E-33CD-42D86D9937F5AFDB.pdf PDF
48C71F36-F14E-8501-2A85945F358C6068.xlsx XLSX spreadsheet
441CA1BC-A59E-E520-9F472E421C5515A7.pdf PDF
CCC737E4-C815-7DA9-BAFDD4D8BCA83EAE.pdf PDF
BEA8591A-F056-8D68-013C92A00C2DA843.pdf PDF
1FF79148-03D3-7B1B-77CF64FD687ECA4C.pdf PDF
4764BD72-A4C9-CB3B-C1392F63B1D7AA28.pdf PDF
BCCA0BAC-C5BA-CDB6-49D2EFF559EDAF11.pdf PDF
451DAC14-D169-2A9F-1266443CD504A357.xlsx XLSX spreadsheet
9AEA49E5-D258-E830-CAAB03DD9BBE7883.pdf PDF
D1C75C4E-ACBE-A700-94A3260C246A50BF.pdf PDF
9CF27992-010C-8CAD-3D1BE0F71396D62B.pdf PDF
600ACEFD-D8A4-EF86-6746123A35214FBD.pdf PDF
D465A6BC-B38E-009F-4BA8EFA38CE55315.pdf PDF
E99102BF-B146-146D-35DFAF9763C1170B.pdf PDF
455CC78D-B78A-EC66-F7D6D71B8AF36042.pdf PDF
6D302278-A5F3-8508-AEC851283D91EF01.pdf PDF
5FEA932D-A443-F834-C369AEC7AD13A552.pdf PDF
8BE999EA-C1F3-6CAA-1ED2B57E621612FB.pdf PDF
4540076D-DA44-888C-413CAB868FEC6141.xlsx XLSX spreadsheet
477EEBB5-9B64-4073-39F4D92B43E61BB0.pdf PDF
47647B12-EF69-CBAE-3877E615229CE346.pdf PDF
379F0AFD-BC67-5833-47CED9B9F8A77644.pdf PDF
8F33C1D9-B606-E1D0-F77CFF24E442EF1B.pdf PDF
4491B391-0B2C-57F1-169E865F334A5FAD.xlsx XLSX spreadsheet
4703BAFF-A637-A4BC-D31224A6D85981B6.pdf PDF
Show 40 more

Latest 50 of 147 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Item Quantity Units Description Cost

1 1 Each

Installation by August 17, 2026 (Must be installed by date.) Vendor shall furnish all labor, tools, rigging, and incidental materials required to set, assemble, level, anchor, and connect the compressor system at the designated installation location. Installation shall include: mechanical assembly and re-connection of any components disassembled for transport; connection to the existing compressed air distribution header at the point of connection identified by the County; connection of condensate drain lines to the nearest available floor drain; and verification that all safety devices, gauges, and controls are properly mounted and functional. Electrical rough-in (conduit, disconnect, and branch circuit wiring to the single power connection point on the unit) is the responsibility of the County and shall be completed prior to the Vendor’s installation visit.

Installation to be completed by:

Included

2 1 System

Model Type and Number:

BRAND NAME(s) OR EQUAL PURCHASE

DESCRIPTION:

3 1 System

SITE READINESS: The County shall provide a level, reinforced concrete or structural floor adequate for the unit weight prior to the scheduled installation date. Vendor shall provide certified weight data to the County not less than ten

(10) business days in advance of delivery to allow floor-loading verification. Included

ELECTRICAL ROUGH-IN (COUNTY-FURNISHED):

Electrical conduit, disconnect switch, and branch circuit wiring from the County facility panel to the single power connection point on the compressor unit is the responsibility of the County and shall be completed and inspected before the Vendor’s startup visit. County

COMPRESSED AIR DISTRIBUTION PIPING

(COUNTY-FURNISHED): Compressed air distribution piping beyond the system outlet connection point to the laboratory header is the responsibility of the County and shall be completed prior to the startup and commissioning visit. County

FACTORY-AUTHORIZED STARTUP AND

COMMISSIONING: Documentation of all commissioning data on a startup report to be submitted to the County within five (5) business days of completion. Included

6 1 System Training

OPERATOR AND MAINTENANCE TRAINING: The Vendor’s factory-authorized technician shall conduct on-site operator and maintenance training at the time of startup and commissioning. O&M manual is provided. Training shall be a minimum of two (2) hours in duration.

Included

7 24 Months Warranty – compressor pump ≥ 24 months from acceptance

Included

8 12 Months Warranty – system ≥ 12 months parts and labor

Included

CRITICAL:

All components and sub-assemblies of the air compressor package, whether shipped assembled or knocked down, must be capable of passing through a 46-inch (46") wide doorframe without structural modification to the building.

Included

DELIVERY:

F.O.B. – Destination: System shall be delivered via lift-gate equipped truck to the designated delivery point at the County facility. The Vendor shall offload and stage the equipment at the installation site. Any disassembly required for transport through the 46-inch doorframe shall be documented, and re-assembly instructions shall be provided. Vendor shall coordinate delivery access with the County not less than five

(5) business days before the scheduled delivery date.

Any required permits or licenses are the responsibility and cost of Vendor. Any calibration will have a certificate provided to the County at the responsibility and cost of Vendor. Included

12 All Costs Included

Total Costs with System, Installation, Training, and Warranty $

13 1-5 Annual Rate Optional Extended Warranty Coverage $