9-Attachment F- 73135-Permit Submission REV.pdf
PDF 5 MB Posted
- Attached to
- Gerry Hyland GC Roof and HVAC
- Solicitation number
- IFB 2000004148
- Issued by
- Fairfax County, Virginia
About this file
This is a comprehensive set of construction documents for the Roof and HVAC Alterations project for the Gerry Hyland Government Center, located at 8350 Richmond Highway in Alexandria, Virginia, prepared by Gauthier, Alvarado Associates for the Fairfax County Facilities Management Department. The project involves replacing the roof assembly and select rooftop mechanical units along with associated utility work through the building core utility spaces on each floor. The work is scheduled for permit submission on 05-15-2024, with construction to be performed on the existing five-story building constructed in 2000. The project scope includes replacing roof membranes, updating cooling towers, modifying mechanical equipment, and making associated electrical and plumbing modifications.
The project is funded through Fairfax County's Facilities Management Department, with a purchase order number of 8500538935 and engineering services contract number 4400008465. The existing building is a business occupancy type with a gross floor plate of 30,869 square feet and an occupant load of approximately 309 people per floor. The proposed roof areas include a main roof of 31,876 square feet, a penthouse roof of 3,180 square feet, and an entrance canopy of 1,683 square feet. The project will utilize the 2021 Virginia Uniform Statewide Building Code and will maintain the building's existing fire protection systems, including full sprinkler coverage, central station monitoring, fire alarm system, and standpipe systems.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
METAL
ACOUSTICAL TILE
CERAMIC TILE,
CEMENT, GROUT
GYPSUM BOARD,
(RIGID)
INSULATION
(BATT OR LOOSE)
INSULATION
WOOD (ROUGH)
WOOD (FINISHED)
PLYWOOD
(SMALL SCALE)
METAL
(LARGE SCALE)
MATERIALS
MASONRY UNIT
CONCRETE
BRICK
CONCRETE
GRAVEL
EARTH
BUILDING SECTION LETTER
SHEET WHERE CUT
SHEET WHERE DRAWN
SECTION NUMBER
DETAIL NUMBERCOLUMN DESIGNATION
A
ABBREVIATIONS GENERAL NOTES
SYMBOLS BUILDING DATA
INDEX OF DRAWINGSMAPS
ACM ASBESTOS CONTAINING
MATERIALS
ACS FLR ACCESS FLOOR (ING)
ACS PNL ACCESS PANEL
ACST ACOUSTIC (AL)
AD AREA DRAIN
ADJ ADJACENT; ADJUSTABLE
ADDL ADDITIONAL
ADDM ADDENDUM
AFC ABOVE FINISH COUNTER
AFF ABOVE FINISH FLOOR
AL ALUMINUM
ALT ALTERNATE
ANSI AMERICAN NATIONAL STANDARDS
INSTITUTE
APPROX APPROXIMATE
ARCH ARCHITECT (URAL)
ASC ABOVE SUSPENDED CEILING
ASPH ASPHALT
ASTM AMERICAN SOCIETY FOR TESTING
AND MATERIALS
BAL BALANCE
BD BOARD
BITUM BITUMINOUS
BLDG BUILDING
BLKG BLOCKING
BOT BOTTOM
BRDG BRIDGING
BS BOTH SIDES
BTWN BETWEEN
BUR BUILT-UP ROOFING
CAB CABINET
CAP CAPACITY
CH BD CHALKBOARD
CI CAST IRON
CJ CONTROL JOINT
CLG CEILING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CASED OPENING
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONSTR CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
CPT CARPET (ED)
CSK COUNTER SUNK
CT CERAMIC TILE
CU COPPER
CW COLD WATER
D DEPTH; DEEP
DBL DOUBLE
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DN DOWN
DR DOOR
DS DOWNSPOUT
DWG DRAWING
E EAST
EA EACH
EE EACH END
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC (AL)
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSE (URE)
EPDM ETHYLENE PROPYLENE DIENE
MONOMER
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPOSED; EXPANSION
EXT EXTERIOR; EXTINGUISHER
F FAHRENHEIT
F/O FACE OF
FA FIRE ALARM
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FH FIRE HYDRANT
FIN FINISH (ED)
FLASH FLASHING
FLR FLOOR
FLUOR FLUORESCENT
FR FIRE RESISTANT
FRTW FIRE RETARDANT TREATED WOOD
FT FOOT, FEET
FTG FOOTING
FTR FLUE THRU ROOF
FURG FURRING (ED)
GA GAGE
GALV GALVANIZED
GL GLASS
GYP GYPSUM
HB HOSE BIBB
HC HANDICAP
HCW HOLLOW CORE WOOD
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HPT HIGH POINT
HT HEIGHT
HVAC HEATING/VENTILATING/AIR
CONDITIONING
HW HOT WATER
ID INSIDE DIAMETER
INCL INCLUDE (D), (ING)
INFO INFORMATION
INSUL INSULATION; INSULATED
INT INTERIOR
JAN JANITOR
JST JOIST
JT JOINT
L LONG; LENGTH
LAB LABORATORY
LAM LAMINATE (D)
LAV LAVATORY
LBS POUNDS
LF LINEAR FEET
LPT LOW POINT
MACH MACHINE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MKR BD MARKER BOARD
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MED MEDIUM
MTL METAL
MFR MANUFACTURER
MIN MINIMUM; MINUTE
MISC MISCELLANEOUS
MO MASONRY OPENING; MOTOR
OPERATED
MTD MOUNTED
MTG MOUNTING
N NORTH
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
OVHD OVERHEAD
PART PARTIAL
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLYWD PLYWOOD
PNL PANEL
PTD PAINTED
PTN PARTITION
PVC POLYVINYL CHLORIDE
QT QUARRY TILE
R RADIUS; RISER
RD ROOF DRAIN
REINF REINFORCEMENT
REQD REQUIRED
RESIL RESILIENT
REV REVISION
RM ROOM
RO ROUGH OPENING
RTU ROOF TOP UNIT
RWL RAIN WATER LEADER
S SOUTH
SAPC SUSPENDED ACOUSTICAL PANEL
CEILING
SATC SUSPENDED ACOUSTICAL TILE
CEILING
SCHED SCHEDULE (D)
SCW SOLID CORE WOOD
SECT SECTION
SF STOREFRONT; SQUARE FOOT
SIM SIMILAR
SQ SQUARE
SST STAINLESS STEEL
ST STREET
STC SOUND TRANSMISSION CRITERIA
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURE (AL)
SUSP SUSPENDED
SYMM SYMMETRY (ICAL)
T TREAD
T&G TONGUE AND GROOVE
T/O TOP OF
TEL TELEPHONE
TEMP TEMPERATURE; TEMPORARY
THK THICK (NESS)
THRU THROUGH
TK BD TACK BOARD
TOW TOP OF WALL
TRTD TREATED
TV TELEVISION
TYP TYPICAL
UC UNDER COUNTER
UGND UNDERGROUND
UL UNDERWRITER'S LABORATORIES
UON UNLESS OTHERWISE NOTED
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VTR VENT THRU ROOF
VWC VINYL WALL COVERING
W WIDTH; WASTE; WEST; WIRE
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WDW WINDOW
WP WATERPROOF (ING); WORK POINT
WT WEIGHT
WWR WELDED WIRE REINFORCING
XFMR TRANSFORMER
FI
LE
SC
AL
E:
DA
TE
TI
ME
5- T0
NO
T
TO
S
CA
LE
/13 /24
:20
:31
DRAWING NUMBER
T001
ARCHITECTURE ENGINEERING PLANNING
10201 FAIRFAX BOULEVARD, SUITE 225, FAIRFAX, VIRGINIA
G A U T H I E R A L V A R A D O A S S O C I A T E S
703-241-2202 WWW.GAA-AE.COM
FAIRFAX COUNTY
GERRY HYLAND
ROOF AND HVAC ALTERATIONS
05-15-2024PERMIT SUBMISSION
PROJECT SUMMARY
© COPYRIGHT ALL RIGHTS RESERVED
THESE DRAWINGS ARE PROTECTED UNDER THE
COPYRIGHT ACT OF 1976 AND SHALL NOT BE
REUSED WITHOUT THE WRITTEN PERMISSION OF
GAUTHIER, ALVARADO AND ASSOCIATES
A A101 A301
A101 A501
A101 A501
LOBBY
ROOM DESIGNATION
ROOM NUMBER
1. PERFORM WORK IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL GOVERNING
ORDINANCES, CODES AND REGULATIONS.
2. ALL MATERIALS SHALL COMPLY WITH APPLICABLE CODES, ORDINANCES AND REGULATIONS.
(ALL WOOD FOR FRAMING OR BLOCKING SHALL BE FIRE RETARDANT TREATED.)
3. VISIT AND BECOME FAMILIAR WITH THE SITE AND BUILDING PRIOR TO BID. INCLUDE THE COST
OF ALL WORK DESCRIBED IN THE CONTRACT DOCUMENTS AND THAT IS REQUIRED OR
REASONABLY IMPLIED TO ACHIEVE THE DESIGN INTENT OF THE CONTRACT DOCUMENTS.
4. NOTIFY THE ARCHITECT OF ANY CONFLICTS BETWEEN EXISTING CONDITIONS AND THE NEW
WORK, OF ANY OMISSIONS OR CONFLICTS IN THE DRAWINGS AND ANY RESTRICTIONS RELATED
TO THE EXECUTION OF THE WORK INCLUDING THE COORDINATION WITH OTHER TRADES.
5. FIELD VERIFY ALL CONDITIONS AND DIMENSIONS INDICATED AND NOTIFY THE ARCHITECT OF
ANY VARIATION PRIOR TO THE PURCHASING OF MATERIALS, FABRICATION OR CONSTRUCTION
OF ANY ITEM.
6. MAINTAIN THE INTEGRITY OF ALL EXISTING FIRE ASSEMBLIES.
7. PROTECT EXISTING BUILDING FROM WEATHER DURING EXECUTION OF THE WORK; AND
PROTECT EXISTING ADJACENT AREAS FROM DAMAGE DURING EXECUTION OF THE WORK. ALL
ITEMS DAMAGED DURING THE WORK SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE.
8. ADJACENT AREAS OF THE EXISTING FACILITY WILL REMAIN IN OPERATION WHILE WORK IS BEING
DONE. ALL WORK SHALL BE COORDINATED WITH THE OWNER'S REPRESENTATIVE, AND SHALL
BE SEQUENCED AND PERFORMED IN A MANNER TO MINIMIZE ANY IMPACTS ON EXISTING
FACILITY OPERATIONS.
9. BUILDING IS CONSTRUCTED WITH REINFORCED CONCRETE POST-TENSION SLABS. NO SLAB
TENDONS SHALL BE CUT.
10. ANY BUILDING UTILITY OR EQUIPMENT SHUTDOWNS SHALL BE COORDINATED WITH FAIRFAX
COUNTY PROJECT MANAGER PRIOR TO SCHEDULING WORK.
VICINITY MAP LOCATION MAP
PROJECT INFORMATION
T001 COVER SHEET
ARCHITECTURAL
A100 SITE AND PHASING PLAN
D101 LOWER ROOF DEMOLITION ROOF PLAN
D102 PENTHOUSE AND ENTRANCE CANOPY DEMOLITION ROOF PLANS
A101 LOWER ROOF PLAN
A102 PENTHOUSE AND ENTRANCE CANOPY ROOF PLANS
A103 ENLARGED PARTIAL ROOF PLAN
A104 5TH FLOOR REFLECTED CEILING PLAN
A501 DETAILS
A502 DETAILS
A503 DETAILS
STRUCTURAL
S101 ROOF PLAN
S201 SECTIONS & DETAILS
PLUMBING
P001 COVER SHEET
P101 ROOF PLAN
P201 ENLARGED ROOF PLANS - GAS
MECHANICAL
M001 COVER SHEET
M101 ROOF PLAN - DEMOLITION
M201 ROOF PLAN
M301 SECTIONS
M601 SCHEDULES
ELECTRICAL
E001 GENERAL NOTES AND SCHEDULES
E101 PARTIAL DEMOLITION ROOF POWER PLAN
E201 PARTIAL ROOF POWER PLAN
E601 SCHEDULES
COOLING TOWER DRAINAGE
A400 SPECIFICATIONS AND DETAILS
A401 ENLARGED PARTIAL ROOF PLAN
A402 5TH FLOOR BUILDING CORE PLAN
A403 1ST FLOOR AND 2ND - 4TH FLOOR BUILDING CORE PLANS
A410 UL INFORMATION
P400 SPECIFICATIONS
P401 PARTIAL ROOF PLAN & RISER
P402 FIRST FLOOR PLAN
P403 PARTIAL PLANS
M401 PARTIAL PLANS
KEY NOTE
REVISION NUMBER
PROJECT CONSISTS REPLACEMENT OF ROOF ASSEMBLY AND SELECT ROOF TOP
MECHANICAL UNITS ALONG WITH ASSOCIATED UTILITY WORK THROUGH THE BUILDING
CORE UTILITY SPACES ON EACH FLOOR.
MO-DA-YR
05-15-24
SCOPE OF WORK:
EXISTING BUILDING INFORMATION
ORIGINAL BLDG CODE AND YEAR: VSBC 1996
YEAR BUILT: 2000
USE GROUP OF BUILDING: B - BUSINESS
TYPE OF CONSTRUCTION: 2B
NUMBER OF STORIES: 5 FLOORS + PENTHOUSE
HIGH RISE BUILDING: NO
GROSS FLOOR PLATE AREA: 30,869 SF
OCCUPANT LOAD (BUSINESS 1/100): 309 PER FLOOR
EXISTING FIRE PROTECTION SYSTEM
SPRINKLERS: FULLY
APPROVED CENTRAL STATION: YES
FIRE ALARM SYSTEM: YES
STANDPIPES: YES
EXISTING FIRE RATING REQUIREMENTS
APPLICABLE CODES
2021 VIRGINIA UNIFORM STATEWIDE BUILDING CODE
2021 VIRGINIA EXISTING BUILDING CODE, LEVEL 2 ALTERATIONS PER SECTION 601.2.2
2020 NFPA 70 NATIONAL ELECTRIC CODE
2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES (ICC/ANSI A117.1)
PROPOSED AREA OF WORK
USE GROUP: U-UTILITY
TYPE OF CONSTRUCTION: II A
FLOOR NUMBER: PENTHOUSE AND ROOF
1ST - 5TH FLOORS - MECHANICAL ROOM
BUILDING HEIGHT: 64'-8" (NOT INCLUDING PENTHOUSE)
ROOF AREAS: MAIN ROOF 31,876 SF
PENTHOUSE ROOF 3,180 SF
ENTRANCE CANOPY 1,683 SF
ROOF WIND
UPLIFT VALUES: FIELD 34.16 LB/FT2
PERIMETER 53.63 LB/FT2
CORNER 79.09 LB/FT2
RISK CATEGORY: II
EXPOSURE CATEGORY: B
COLUMNS: 2 HR
BEARING WALLS: NA
NONBEARING WALLS/PARTITIONS: 0
2 HRFLOOR CONSTRUCTION:
ROOF CONSTRUCTION: 2 HR
SHAFT ENCLOSURES: 2 HR UL U438 (EXISTING)
EXISTING REINFORCED CONC FLOOR SLAB THICKNESS = 9" MIN
EXISTING REINFORCED CONC ROOF SLAB THICKNESS = 9" MIN
EXISTING REINFORCED CONC COLUMNS 24"x24"
- EXCEEDS TABLE 722.2.4 REQUIREMENTS
- EXCEEDS TABLE 722.2.2.1 REQUIREMENTS
- EXCEEDS TABLE 722.2.2.1 REQUIREMENTS
FACILITIES MANAGEMENT DEPARTMENT
GERRY HYLAND GOVERNMENT CENTER
POINTS OF CONTACT PROJECT
LOCATION
GERRY HYLAND
GOVERNMENT CENTER
AMANDA OSIECKI, aosiecki@gaa-ae.com
GAUTHIER, ALVARADO & ASSOCIATES
10201 FAIRFAX BLVD, SUITE 225, FAIRFAX, VA 22030
TELEPHONE: 703-241-2202
A/E'S REPRESENTATIVE:
8350 RICHMOND HWY, ALEXANDRIA, VA
GOVERNMENT CENTER
BUILDING PURPOSE / FUNCTION:
DOUG HATFIELD, PROJECT MANAGER
FAIRFAX COUNTY FACILITIES MANAGEMENT DEPARTMENT
12000 GOVERNMENT CENTER PARKWAY, SUITE 424
FAIRFAX, VIRGINIA 22035
TELEPHONE: 703-324-3930
OWNER'S REPRESENTATIVE:
05-15-24
05-15-24
KRISTA LYNN STRICKLAND
Lic. No. 011890
AMANDA C. OSIECKI
Lic. No. 53637
RALPH HOFFMAN
Lic. No. 018804
FI
LE
SC
AL
E:
DA
TE
TI
ME
5- A1
NO
T
TO
S
CA
LE
/15 /24
:36
:26
PROJECT TITLE
REVISIONS
NO. DATE DESCRIPTION
DRAWN BY
CHECKED BY
DATE
DRAWING TITLE
DRAWING NUMBER
5-15-24
G A U T H I E R A L V A R A D O A S S O C I A T E S 703-241-2202
WWW.GAA-AE.COM
PROJECT STATUS
GAA PROJECT NO. 731E35
CONSTRUCTION DOCUMENTS
GERRY HYLAND
ROOF AND HVAC
ALTERATIONS
© COPYRIGHT ALL RIGHTS RESERVED
THESE DRAWINGS ARE PROTECTED UNDER THE
COPYRIGHT ACT OF 1976 AND SHALL NOT BE
REUSED WITHOUT THE WRITTEN PERMISSION OF
GAUTHIER, ALVARADO AND ASSOCIATES
05-15-24
FAIRFAX COUNTY
FACILITIES
MANAGEMENT
DEPARTMENT
Purchase Order No.
8500538935
Engineering Services, Contract No. 4400008465
ALEXANDRIA, VA
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x xxxxxxxxxxx x x x x xx xxx x x x x x
RICHMOND HIGHWAY
BUCKMAN R
OAD
FIRE DEPARTMENT ACCESS
ENTRANCE
EGRESS
STAIR
ENTRANCE
MAIN
ENTRANCE
FAIRFAX COUNTY VEHICLE PARKING
ACCESSIBLE
PARKING - 2
ACCESSIBLE
PARKING - 1
ACCESSIBLE
PARKING - 3
FENCED
PATIO
BUS SHELTER
BLDG SIGNAGE
LOADING
TRASH
ELEC
DROP
OFF
FIRE DEPT
CONNECTION
SITE & PHASING PLAN
1" = 40"
20' 0 40' 80'
1" = 40'
PROPOSED CONTRACTOR PARKING / TRAILER AREA
SITE & PHASING PLAN KEYNOTES
1. THIS PLAN IS PROPOSED BY THE DESIGNER, CONTRACTOR IS RESPONSIBLE FOR PRODUCING AND SUBMITTING PHASING DOCUMENTATION REQUIRED PER PROJECT
SPECIFICATIONS AND OWNER DIRECTION.
2. THIS PLAN IS NOT A COMPLETE REPRESENTATION OF ALL EXISTING CONDITIONS, THIS PLAN IS SCHEMATIC IN NATURE AND INTENDS TO SHOW THE GENERAL EXTENT
AND LAYOUT OF EXISTING SITE.
3. CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL TRADES DURING CONSTRUCTION. CONTRACTOR SHOULD REVIEW ALL TRADES FOR ANY MISCELLANEOUS WORK
NOT SHOWN ON ARCHITECTURAL DRAWINGS TO PROVIDE A 100% COMPLETE PROJECT.
4. COORDINATE SCHEDULE AND SECURITY REQUIREMENTS WITH FAIRFAX COUNTY PROJECT MANAGER.
5. ANY EXISTING SECURITY SYSTEMS MUST BE PROTECTED AND OPERATIONAL AT ALL TIMES. CONTRACTOR TO SUBMIT WORK SCHEDULE WITH DAYS AND HOURS FOR COORDINATION WITH BUILDING SECURITY AND FAIRFAX COUNTY PROJECT MANAGER. PHASING SCHEDULE TO BE SUBMITTED WEEKLY FOR FOLLOWING WEEKS STAGING
AREAS.
6. ACCESSIBLE PARKING, STRIPPED ACCESS AISLES, AND STRIPPED ACCESS PATHS SHALL REMAIN UNOBSTRUCTED THROUGHOUT ENTIRETY OF PROJECT UNLESS GIVEN
WRITTEN PERMISSION OF THE OWNER.
7. FIRE DEPARTMENT ACCESS AREA AND FIRE DEPARTMENT CONNECTION SHALL REMAIN UNOBSTRUCTED THROUGHOUT ENTIRETY OF PROJECT.
8. DO NOT DISTURB ANY TRESS, PLANTS, OR BUSHES WITHOUT EXPRESSED WRITTEN PERMISSION FROM OWNER.
9. ANY SITE ELEMENT DAMAGE AND BUILDING EXTERIOR DAMAGE CAUSED BY CONSTRUCTION SHALL BE REPAIRED BY THE CONTRACTOR BEFORE PROJECT TURNOVER.
10. GRASS RE-SEEDING AND LANDSCAPING REPAIRS SHALL OCCUR NOT LATER THAT OCTOBER 15TH.
11. ALL ROOFING CONSTRUCTION ACTIVITIES SHALL OCCUR BETWEEN MAY AND OCTOBER.
GENERAL SITE & PHASING PLAN NOTES
ROOF AREA
#1
ROOF AREA
#2
ROOF AREA
#3
ROOF AREA
#4
ROOF AREA
#5
ROOF AREA
#6
ROOF AREA
#7
ROOF AREA
#8 (PENTHOUSE)
LEGEND
PROVIDE TEMPORARY OVERHEAD
PROTECTION THROUGHOUT
ENTIRETY OF CONSTRUCTION
ROOF AREA
#9 (CANOPY)
x x x EXISTING FENCE
EXISTING BUILDING / STRUCTURE
PROPOSED AREA
PROPOSED CRANE STAGING AREA
ARCHITECTURAL
A100
SITE & PHASING PLAN
DAP
KLS
ROOF AREA DIVISION
KRISTA LYNN STRICKLAND
Lic. No. 011890
SC
AL
E:
DA
TE
TI
ME
5-
AP
-6 P
1/4
1' -0
/30 /24
:43
:14
1 2 3 4 5 6 7 8 9 10 11 12
A
A.1
B
C
C.9
D
1 2 3 4 5 6 7 8 9 1110 12
A
A.1
B
C
C.9
D
FI
LE
SC
AL
E:
DA
TE
TI
ME
5- D1
3/3
2"
1' -0
/15 /24
:33
:53
PROJECT TITLE
REVISIONS
NO. DATE DESCRIPTION
DRAWN BY
CHECKED BY
DATE
DRAWING TITLE
DRAWING NUMBER
5-15-24
G A U T H I E R A L V A R A D O A S S O C I A T E S 703-241-2202
WWW.GAA-AE.COM
PROJECT STATUS
GAA PROJECT NO. 731E35
CONSTRUCTION DOCUMENTS
GERRY HYLAND
ROOF AND HVAC
ALTERATIONS
© COPYRIGHT ALL RIGHTS RESERVED
THESE DRAWINGS ARE PROTECTED UNDER THE
COPYRIGHT ACT OF 1976 AND SHALL NOT BE
REUSED WITHOUT THE WRITTEN PERMISSION OF
GAUTHIER, ALVARADO AND ASSOCIATES
05-15-24
FAIRFAX COUNTY
FACILITIES
MANAGEMENT
DEPARTMENT
Purchase Order No.
8500538935
Engineering Services, Contract No. 4400008465
ALEXANDRIA, VA
1. THIS PLAN IS NOT A COMPLETE REPRESENTATION OF ALL THE EXISTING CONDITIONS.
THIS PLAN IS SCHEMATIC IN NATURE AND INTENDS TO SHOW THE GENERAL EXTENT
AND LAYOUT OF THE EXISTING FACILITY.
2. CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL TRADES DURING
CONSTRUCTION. CONTRACTOR SHALL REVIEW ALL TRADES FOR ANY MISCELLANEOUS
WORK NOT SHOWN ON ARCHITECTURAL DRAWINGS TO PROVIDE A 100% COMPLETE
PROJECT.
3. FIELD VERIFY EXISTING CONDITIONS. IF A CONDITION IS NOT INDICATED ON DRAWINGS
AND IS NOT SIMILAR TO OTHER DETAILED CONDITIONS, DOCUMENT AND SUBMIT AN
RFI FOR A/E DIRECTION.
4. REMOVE INDICATED EXISTING CONSTRUCTION CLEANLY AND LEAVE EXISTING
CONSTRUCTION TO REMAIN READY TO RECEIVE NEW WORK.
5. REMOVE EXISTING CONSTRUCTION, INCLUDING MECHANICAL, PLUMBING, ELECTRICAL
WORK ETC., AS NECESSARY AND WHEREEVER NECESSARY TO PROVIDE WORK IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS.
6. AS DIRECTED BY THE OWNER REMOVE, BOX, LABEL, AND DELIVER TO OWNER,
MISCELLANEOUS ITEMS OF EQUIPMENT DESIGNATED FOR REMOVAL OR LOCATED ON
SURFACES WHICH ARE NECESSARY TO BE REMOVED, UNLESS INDICATED FOR
RELOCATION.
7. DOCUMENT EXISTING SLOPES, CRICKETS AND SUMPS PRIOR TO DEMOLITION. REMOVE
EXISTING BUILT-UP ROOFING SYSTEM TO CONCRETE DECK. REMOVE RELATED
MEMBRANE AND LIQUID FLASHINGS. EXISTING FASCIA, AND COPINGS, AND METAL
FLASHING ASSEMBLIES ARE TO REMAIN UNLESS OTHERWISE NOTED.
8. PROTECT EXISTING EQUIPMENT TO REMAIN DURING CONSTRUCTION INCLUDING
MECHANICAL UNITS, DUCTING, PIPES, VENTS, PLATFORMS, ETC.
9. ONLY DEMOLISH THE AMOUNT OF ROOF MEMBRANE THAT CAN BE REPLACED IN THE
COURSE OF A DAY. AT NO TIME SHOULD THE BUILDING BE LEFT EXPOSED OVERNIGHT.
10. IF EXISTING EQUIPMENT DESIGNATED TO REMAIN IS DAMAGED AS A RESULT OF
DEMOLITION WORK, CONTRACTOR IS RESPONSIBLE FOR REPAIR OR REPLACEMENT.
11. THROUGHOUT ROOF, DETACHED LIGHTNING PROTECTION SYSTEM COMPONENTS ARE
LAYING ACROSS ROOF. SALVAGE FOR REINSTALLATION AND RELOCATE AS REQUIRED
TO COMPLETE CONSTRUCTION. COORDINATE WITH NEW WORK.
12. CONTRACTOR TO SCAN ALL PROSPECTIVE SLAB DRILL LOCATIONS BY MEANS OF
DIGITAL X-RAY OR GPR IMAGING TO VERIFY THAT THERE ARE NO CONFLICTS.
CONTRACTOR TO ADJUST CORE DRILL LOCATIONS AS REQUIRED. BUILDING IS
CONSTRUCTED WITH REINFORCED CONCRETE POST-TENSION SLABS. NO SLAB
TENDONS SHALL BE CUT.
GENERAL DEMOLITION NOTES
ARCHITECTURAL
D101
LOWER ROOF
DEMOLITION ROOF PLAN
DAP
KLS
D101 A501
D101 A501
D101 A501
D101 A501
TYPTYP
TYP
D101 A501
TYP
D101 A501
TYP
D101 A501
TYP
D101 A501
TYP
D101 A501
TYP
D101 A501
TYP
D101 A501
EXISTING SLED STRUCTURE. CONTRACTOR TO TEMPORARILY
RELOCATE ON ROOF TO ALLOW FOR DEMOLITION. COORDINATE
WITH SLED OWNER. SLED OWNER TO RECONFIGURE EQUIPMENT
OR CABELING REQUIRED TO ALLOW FOR ROOFING DEMOLITION TO
OCCUR.
REMOVE EXISTING MECHANICAL EQUIPMENT PER MEP DRAWINGS.
REMOVE EXISTING PAVERS AND MEMBRANE PADS.
REMOVE A SALVAGE EXISTING EQUIPMENT AND SKID ASSEMBLY
FOR RELOCATION DURING NEW WORK. TEMPORARILY RELOCATE
AND DISCONNECT UTILITIES AS REQUIRED FOR CONSTRUCTION.
EXISTING PENETRANT(S) TO REMAIN, REMOVE PENETRATION
POCKET ASSEMBLY.
EXISTING EQUIPMENT PLATFORM TO REMAIN.
EXISTING SMALL EQUIPMENT PLATFORM TO REMAIN.
REMOVE EXISTING RAISED PADS AND CURBS TO CONCRETE DECK.
REMOVE EXISTING SPLASH BLOCK.
EXISTING TELECOM RACEWAY ON PIPE SUPPORTS TO REMAIN,
RELOCATE AS REQUIRED FOR CONSTRUCTION. COORDINATE WITH
OWNER AND NEW WORK.
EXISTING ROOF SAFETY TIE OFF ANCHORS TO REMAIN, REMOVE
PENETRATION POCKET ASSEMBLY.
EXISTING MOVEABLE STEP TO REMAIN. RELOCATE AS REQUIRED
FOR CONSTRUCTION.
EXISTING PLATFORM STAIR STEPS RESTING ON PAVERS. REMOVE
AND SALVAGE PAVERS UNDER STAIR STRINGER FOR
REINSTALLATION DURING NEW WORK. PROVIDE TEMPORARY
SUPPORTS AT STRINGERS AS REQUIRED DURING CONSTRUCTION.
NOT USED.
REMOVE PENETRATION POCKET ASSEMBLY. CONFIRM EXISTING
PENETRATE IS ABANDONED-IN-PLACE, IF SO REMOVE. REMOVE
ANY WIRING AND CONDUIT BACK TO SOURCE PANEL. REMOVE ANY
PIPING BACK TO SOURCE AND CAP. PATCH ANY PENETRATIONS AS
A RESULT OF DEMO TO MATCH EXISTING ADJACENT
CONSTRUCTION.
EXISTING VENT TO REMAIN, REMOVE FLASHING PER DETAIL 6/A502.
EXISTING DUCT PENETRATION ASSEMBLIES THROUGH CONCRETE
DECK TO REMAIN, DO NOT DISTURB. REMOVE ADJACENT ROOF
ASSEMBLY TO CONCRETE DECK.
DOCUMENT EXISTING SUMPS TO MATCH DURING NEW
CONSTRUCTION, REMOVE ADJACENT SUMP AND DRAIN ASSEMBLY
PER DETAIL 6/A501.
DEMOLITION KEY NOTES
D1
D2
D1
D2
D2
LOWER ROOF
DEMOLITION ROOF PLAN
3/32" = 1'-0"
D3
D4
D101 A501
TYPTYP
D5
D5
D5
D5
D5 D5
D5 D5
D15
D43 D101 A501
TYP
D6
D6
D15
D7
D7
D6
D5
D3
TYP
D8
D8
TYP
D9
D9
D9
D10
D10
TYP
D5
D5
TYP
D5
TYP
D11
TYP
D5
D12
D12
D13
D13
D15
D5
10' 0 10' 20'
3/32" = 1'-0"
D14
D6
D15
D15
D5
D15
D16
D16
D16
D11
TYP
D16
D5
D5
D16
D5
D16
PARTITION / CONSTRUCTION TO REMAIN
REMOVE PARTITION / CONSTRUCTION
LEGEND:
D11
MECHANICAL
PENTHOUSE
P02
STAIR #1
P00
ELEV #1
ELEVATOR
MACHINE ROOM
P03
D17
D17
D18
D18
D18
TYP
D18
TYP
SC
AL
E:
DA
TE
TI
ME
5- D1
3/3
2"
1' -0
/15 /24
:36
:28
PROJECT TITLE
REVISIONS
NO. DATE DESCRIPTION
DRAWN BY
CHECKED BY
DATE
DRAWING TITLE
DRAWING NUMBER
5-15-24
G A U T H I E R A L V A R A D O A S S O C I A T E S 703-241-2202
WWW.GAA-AE.COM
PROJECT STATUS
GAA PROJECT NO. 731E35
CONSTRUCTION DOCUMENTS
GERRY HYLAND
ROOF AND HVAC
ALTERATIONS
© COPYRIGHT ALL RIGHTS RESERVED
THESE DRAWINGS ARE PROTECTED UNDER THE
COPYRIGHT ACT OF 1976 AND SHALL NOT BE
REUSED WITHOUT THE WRITTEN PERMISSION OF
GAUTHIER, ALVARADO AND ASSOCIATES
05-15-24
FAIRFAX COUNTY
FACILITIES
MANAGEMENT
DEPARTMENT
Purchase Order No.
8500538935
Engineering Services, Contract No. 4400008465
ALEXANDRIA, VA
1. THIS PLAN IS NOT A COMPLETE REPRESENTATION OF ALL THE EXISTING CONDITIONS. THIS PLAN IS
SCHEMATIC IN NATURE AND INTENDS TO SHOW THE GENERAL EXTENT AND LAYOUT OF THE
EXISTING FACILITY.
2. CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL TRADES DURING CONSTRUCTION.
CONTRACTOR SHALL REVIEW ALL TRADES FOR ANY MISCELLANEOUS WORK NOT SHOWN ON
ARCHITECTURAL DRAWINGS TO PROVIDE A 100% COMPLETE PROJECT.
3. FIELD VERIFY EXISTING CONDITIONS. IF A CONDITION IS NOT INDICATED ON DRAWINGS AND IS NOT SIMILAR TO OTHER DETAILED CONDITIONS, DOCUMENT AND SUBMIT AN RFI FOR A/E DIRECTION.
4. REMOVE INDICATED EXISTING CONSTRUCTION CLEANLY AND LEAVE EXISTING CONSTRUCTION TO
REMAIN READY TO RECEIVE NEW WORK.
5. REMOVE EXISTING CONSTRUCTION, INCLUDING MECHANICAL, PLUMBING, ELECTRICAL WORK ETC., AS NECESSARY AND WHEREEVER NECESSARY TO PROVIDE WORK IN ACCORDANCE WITH THE
CONTRACT DOCUMENTS.
6. AS DIRECTED BY THE OWNER REMOVE, BOX, LABEL, AND DELIVER TO OWNER, MISCELLANEOUS
ITEMS OF EQUIPMENT DESIGNATED FOR REMOVAL OR LOCATED ON SURFACES WHICH ARE
NECESSARY TO BE REMOVED, UNLESS INDICATED FOR RELOCATION.
7. DOCUMENT EXISTING SLOPES, CRICKETS AND SUMPS PRIOR TO DEMOLITION. REMOVE EXISTING
BUILT-UP ROOFING SYSTEM TO CONCRETE DECK. REMOVE RELATED MEMBRANE AND LIQUID
FLASHINGS. EXISTING FASCIA, AND COPINGS, AND METAL FLASHING ASSEMBLIES ARE TO REMAIN
UNLESS OTHERWISE NOTED.
8. PROTECT EXISTING EQUIPMENT TO REMAIN DURING CONSTRUCTION INCLUDING MECHANICAL
UNITS, DUCTING, PIPES, VENTS, PLATFORMS, ETC.
9. ONLY DEMOLISH THE AMOUNT OF ROOF MEMBRANE THAT CAN BE REPLACED IN THE COURSE OF A
DAY. AT NO TIME SHOULD THE BUILDING BE LEFT EXPOSED OVERNIGHT.
10. IF EXISTING EQUIPMENT DESIGNATED TO REMAIN IS DAMAGED AS A RESULT OF DEMOLITION WORK, CONTRACTOR IS RESPONSIBLE FOR REPAIR OR REPLACEMENT.
11. THROUGHOUT PENTHOUSE ROOF, DETACHED LIGHTNING PROTECTION SYSTEM COMPONENTS ARE
LAYING ACROSS ROOF. SALVAGE FOR REINSTALLATION AND RELOCATE AS REQUIRED TO
COMPLETE CONSTRUCTION. COORDINATE WITH NEW WORK.
GENERAL DEMOLITION NOTES
ARCHITECTURAL
D102
PENTHOUSE AND
ENTRANCE CANOPY
ROOF DEMOLITION PLANS
DAP
KLS
D102 A503
D102 A503 TYP
D102 A503
D102 A502
TYP
4A D102 A503
TYP
PENTHOUSE
ROOF DEMOLITION PLAN
3/32" = 1'-0"
ENTRANCE CANOPY
ROOF DEMOLITION PLAN
3/32" = 1'-0"
10' 0 10' 20'
3/32" = 1'-0"
10' 0 10' 20'
3/32" = 1'-0"
EXISTING LADDER ASSEMBLY TO REMAIN.
EXISTING COPING ON TOP OF ROOF SCREEN WALL TO REMAIN.
EXISTING SKYLIGHT ASSEMBLIES TO REMAIN, DO NOT DISTURB.
EXISTING PREFAB PANELS AND METAL FLASHING TO REMAIN.
TRANSLUCENT CANOPY ASSEMBLY BELOW, DO NOT DISTURB
EXISTING TELECOM RACEWAY ON PIPE SUPPORTS TO REMAIN,
RELOCATE AS REQUIRED FOR CONSTRUCTION. COORDINATE WITH
OWNER AND NEW WORK.
EXISTING EQUIPMENT AND SKID ASSEMBLY TO REMAIN.
TEMPORARILY RELOCATE AND DISCONNECT UTILITIES AS
REQUIRED FOR CONSTRUCTION. COORDINATE WITH NEW WORK.
EXISTING PENETRANT(S) TO REMAIN, REMOVE PENETRATION
POCKET ASSEMBLY.
EXISTING VENT TO REMAIN, REMOVE FLASHING PER DETAIL 6/A502.
EXISTING STACK / GOOSENECK VENT TO REMAIN. REMOVE ROOF
FLASHING PER DETAIL 3/A503.
DOCUMENT EXISTING SUMPS TO MATCH DURING NEW
CONSTRUCTION, REMOVE ADJACENT SUMP AND DRAIN ASSEMBLY
PER DETAIL 6/A501.
EXISTING SCUPPER ASSEMBLY TO REMAIN, REMOVE ADJACENT
MEMBRANE FLASHING AND ROOFING PER DETAIL 2/A503
DEMOLITION KEY NOTES
OPEN TO BELOW
TYPTYP
TYP
4B D102 A503
TYP
D102 A503
TYP
6 7
E
F
F
E
TYP
D1
D2
D3
D4
D5
D1
D2 D3
D4
D6
D5
D7
D8
D7
D7
D8
D8
D8D8
D6
D102 A501
TYP, SIM
PARTITION / CONSTRUCTION TO REMAIN
REMOVE PARTITION / CONSTRUCTION
LEGEND:
D9
D9
D9
D10
D10
D10
D11
D11
D11
D12
D12
D12
1 2 3 4 5 6 7 8 9 10 11 12
A
A.1
B
C
C.9
D
1 2 3 4 5 6 7 8 9 1110 12
A
A.1
B
C
C.9
D
FI
LE
SC
AL
E:
DA
TE
TI
ME
5- A1
3/3
2"
1' -0
/15 /24
:36
:26
PROJECT TITLE
REVISIONS
NO. DATE DESCRIPTION
DRAWN BY
CHECKED BY
DATE
DRAWING TITLE
DRAWING NUMBER
5-15-24
G A U T H I E R A L V A R A D O A S S O C I A T E S 703-241-2202
WWW.GAA-AE.COM
PROJECT STATUS
GAA PROJECT NO. 731E35
CONSTRUCTION DOCUMENTS
GERRY HYLAND
ROOF AND HVAC
ALTERATIONS
© COPYRIGHT ALL RIGHTS RESERVED
THESE DRAWINGS ARE PROTECTED UNDER THE
COPYRIGHT ACT OF 1976 AND SHALL NOT BE
REUSED WITHOUT THE WRITTEN PERMISSION OF
GAUTHIER, ALVARADO AND ASSOCIATES
05-15-24
FAIRFAX COUNTY
FACILITIES
MANAGEMENT
DEPARTMENT
Purchase Order No.
8500538935
Engineering Services, Contract No. 4400008465
ALEXANDRIA, VA
ARCHITECTURAL
A101
LOWER ROOF PLAN
DAP
KLS
A101 A502
A101 A501
A101 A501
A101 A501
A101 A501
TYPTYP
TYP
A101 A501
TYP
A101 A501 3
A101 A501
TYP
A101 A501
TYP
A101 A501
TYP
SIM, TYP
A101 A502 TYP
A101 A501
TYP
A101 A502
TYP
A101 A501
PROVIDE FLASHING ON EXISTING STRUCTURAL POSTS PER DETAIL 1/A502.
NEW MECHANICAL EQUIPMENT PER MEP DRAWINGS. PROVIDE FLASHING AND EQUIPMENT
SUPPORT CURB ADAPTOR ASSEMBLY PER DETAIL 7/A501.
LOCATE SLED IN EXISTING LOCATION. PROVIDE ADDITIONAL WALK PADS BELOW SLED PER
MANUFACTURERS REQUIREMENTS.
NOT USED
NOT USED
PROVIDE WALKWAY PAD FROM BUR MEMBRANE MFR, LOCATE AS INDICATED.
RELOCATE SKID AND SKID MOUNTED EQUIPMENT AS LOCATED. RECONNECT UTILITIES AND
ENSURE EQUIPMENT IS FUNCTIONING PROPERLY. PROVIDE WALKWAY PADS UNDER ENTIRE
SKID ASSEMBLY.
PROVIDE FLASHING AT EXISTING PLATFORM SUPPORTS PER DETAIL 1/A502 OR 3/A503.
CONTRACTOR TO USE EITHER DETAIL FOR EASE OF INSTALLATION WITH SITE CONDITION.
AT RIGID PENETRANTS, PROVIDE LIQUID FLASHING ASSEMBLY PER DETAIL 9/A502. AT
FLEXIBLE PENETRANTS, PROVIDE FLASHING PER DETAIL 5/A502. CONTRACTOR TO VERIFY
PENETRANT TYPES IN FIELD AND EXTEND UTILITIES AS REQUIRED.
NOT USED
RAISE EQUIPMENT 18" ABOVE NEW MEMBRANE SURFACE. PROVIDE FLASHING AT
EQUIPMENT CURB PER DETAIL 3/A502.
AT EQUIPMENT PLATFORM STAIR, EXTEND WALKWAY PADS UNDER STAIR ASSEMBLY.
REINSTALL SALVAGED PAVERS UNDER STAIR STRINGERS TO MATCH PREVIOUS LOCATION.
LOCATE SO STAIR STRINGERS REST ON THE PAVERS, PROVIDE SHIMS AS REQUIRED FOR A
LEVEL INSTALLATION.
REINSTALL SALVAGED MOVEABLE STEP, LOCATE TO MATCH PREVIOUS LOCATION.
PROVIDE REPLACEMENT SPLASH BLOCK TO MATCH EXISTING, LOCATE TO MATCH
PREVIOUS LOCATION.
PROVIDE FLASHING AT ROOF SAFETY TIE OFF ANCHOR PER DETAIL 8/A502.
EXISTING TELECOM RACEWAY, AT EACH EXISTING PIPE SUPPORT PROVIDE STRIP OF
WALKWAY PAD UNDERNEATH. ADHERE STRIP TO ROOF MEMBRANE, SEE DETAIL 4/A502, SIM.
NOT USED
PROVIDE FLASHING AT EXISTING VENT PER DETAIL 6/A502.
PROVIDE PENETRATION BOX ASSEMBLY PER DETAIL 7/A502.
PROVIDE ROOF DRAIN FLASHING ASSEMBLY PER DETAIL 6/A501.
ROOF KEY NOTES
LOWER ROOF PLAN
3/32" = 1'-0"
1. THIS PLAN IS NOT A COMPLETE REPRESENTATION OF ALL THE EXISTING
CONDITIONS. THIS PLAN IS SCHEMATIC IN NATURE AND INTENDS TO SHOW THE
GENERAL EXTENT AND LAYOUT OF THE EXISTING FACILITY.
2. CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL TRADES DURING
CONSTRUCTION. CONTRACTOR SHALL REVIEW ALL TRADES FOR ANY
MISCELLANEOUS WORK NOT SHOWN ON ARCHITECTURAL DRAWINGS TO PROVIDE
A 100% COMPLETE PROJECT.
3. PROVIDE REPLACEMENT ROOF ASSEMBLY. TUCK MEMBRANES UNDER EXISTING
METAL FLASHING THROUGHOUT ENTIRE ROOF. MATCH DOCUMENTED SLOPES,
CRICKETS, AND SUMPS TO MATCH EXISTING ROOF. SEE DETAIL 1/A501 FOR
TYPICAL ROOF MEMBRANE ASSEMBLY NOTES.
4. PROTECT EXISTING EQUIPMENT TO REMAIN DURING CONSTRUCTION INCLUDING
MECHANICAL UNITS, DUCTING, PIPES, VENTS, PLATFORMS, ETC.
5. IF EXISTING EQUIPMENT DESIGNATED TO REMAIN IS DAMAGED AS A RESULT OF
CONSTRUCTION, CONTRACTOR IS RESPONSIBLE FOR REPAIR OR REPLACEMENT.
6. CONTRACTOR TO REPAIR AND RE-CERTIFY EXISTING LIGHTNING PROTECTION
SYSTEM. CONTRACTOR TO PROVIDE A RE-CERTIFICATION REPORT.
7. CONTRACTOR TO SCAN ALL PROSPECTIVE SLAB DRILL LOCATIONS BY MEANS OF
DIGITAL X-RAY OR GPR IMAGING TO VERIFY THAT THERE ARE NO CONFLICTS.
CONTRACTOR TO ADJUST CORE DRILL LOCATIONS AS REQUIRED. BUILDING IS
CONSTRUCTED WITH REINFORCED CONCRETE POST-TENSION SLABS. NO SLAB
TENDONS SHALL BE CUT.
8. CONTRACTOR TO REMOVE AND REINSTALL METAL GRATE AS REQUIRED TO
ALLOW ROOFING UNDER PLATFORMS.
GENERAL ROOF NOTES
TYP
A101 A501
TYP
TYP
A101 A103
TYP
TYP
A1
A2
A3
A2
A3
A4
A5
A6
A7
A9
A9
A9
A9 A9
A9 A9
A9
A19
A9
A8
D7
A1
A11
A8
A16
A15
A13
A12
A11
A6
A12
A13
A19
A14
A14
A15
A16
A14
10' 0 10' 20'
3/32" = 1'-0"
A17
KEY NOTE NUMBER
ROOM DESIGNATION
ROOM NUMBER
LEGEND:
LOBBY
MEMBRANE WALKPAD
(2,400± SF SHOWN)
MECHANICAL
PENTHOUSE
P02
STAIR #1
P00
ELEV #1
ELEVATOR
MACHINE ROOM
P03
A9
A10
A18
A19
A18
A18
'-0
MI
N
A18
TYP
A15
TYP
A20
A18
A20
TYP
A20
TYP
A8
RDRD
RD RD RD RD RD RD
RD RD RD RD RD RD
RDRDRD
10'-0"
MIN
SC
AL
E:
DA
TE
TI
ME
5- A1
3/3
2"
1' -0
/15 /24
:14
:15
PROJECT TITLE
REVISIONS
NO. DATE DESCRIPTION
DRAWN BY
CHECKED BY
DATE
DRAWING TITLE
DRAWING NUMBER
5-15-24
G A U T H I E R A L V A R A D O A S S O C I A T E S 703-241-2202
WWW.GAA-AE.COM
PROJECT STATUS
GAA PROJECT NO. 731E35
CONSTRUCTION DOCUMENTS
GERRY HYLAND
ROOF AND HVAC
ALTERATIONS
© COPYRIGHT ALL RIGHTS RESERVED
THESE DRAWINGS ARE PROTECTED UNDER THE
COPYRIGHT ACT OF 1976 AND SHALL NOT BE
REUSED WITHOUT THE WRITTEN PERMISSION OF
GAUTHIER, ALVARADO AND ASSOCIATES
05-15-24
FAIRFAX COUNTY
FACILITIES
MANAGEMENT
DEPARTMENT
Purchase Order No.
8500538935
Engineering Services, Contract No. 4400008465
ALEXANDRIA, VA
1. THIS PLAN IS NOT A COMPLETE REPRESENTATION OF ALL THE EXISTING
CONDITIONS. THIS PLAN IS SCHEMATIC IN NATURE AND INTENDS TO SHOW THE
GENERAL EXTENT AND LAYOUT OF THE EXISTING FACILITY.
2. CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL TRADES DURING
CONSTRUCTION. CONTRACTOR SHALL REVIEW ALL TRADES FOR ANY
MISCELLANEOUS WORK NOT SHOWN ON ARCHITECTURAL DRAWINGS TO PROVIDE
A 100% COMPLETE PROJECT.
3. PROVIDE REPLACE ROOF MEMBRANE TUCKED INTO EXISTING FLASHING
THROUGHOUT ENTIRE ROOF. SEE DETAIL 1/A501 FOR TYPICAL ROOF MEMBRANE
ASSEMBLY NOTES.
4. PROTECT EXISTING EQUIPMENT TO REMAIN DURING CONSTRUCTION INCLUDING
MECHANICAL UNITS, DUCTING, PIPES, VENTS, PLATFORMS, ETC.
5. IF EXISTING EQUIPMENT DESIGNATED TO REMAIN IS DAMAGED AS A RESULT OF
CONSTRUCTION, CONTRACTOR IS RESPONSIBLE FOR REPAIR OR REPLACEMENT.
6. CONTRACTOR TO REPAIR AND RE-CERTIFY EXISTING LIGHTNING PROTECTION
SYSTEM. CONTRACTOR TO PROVIDE A RE-CERTIFICATION REPORT.
7. PROVIDE REPLACEMENT ROOF ASSEMBLY. TUCK MEMBRANES UNDER EXISTING
METAL FLASHING THROUGHOUT ENTIRE ROOF. MATCH DOCUMENTED SLOPES,
CRICKETS, AND SUMPS TO MATCH EXISTING ROOF. SEE DETAIL 1/A501 FOR
TYPICAL ROOF MEMBRANE ASSEMBLY NOTES.
GENERAL ROOF NOTES
ARCHITECTURAL
A102
PENTHOUSE AND
ENTRANCE CANOPY
ROOF PLANS
DAP
KLS
A102 A503
6 7
E
F
F
E
A102 A503
A102 A502
TYP
4A A102 A503
TYP
PENTHOUSE
ROOF PLAN
3/32" = 1'-0"
ENTRANCE CANOPY
ROOF PLAN
3/32" = 1'-0"
10' 0 10' 20'
3/32" = 1'-0"
10' 0 10' 20'
3/32" = 1'-0"
PROVIDE WALKWAY PAD FROM BUR MEMBRANE MFR, LOCATE AS
INDICATED.
REINSTALLED SKID AND SKID MOUNTED EQUIPMENT AND
RECONNECT UTILITIES. LOCATE TO MATCH PREVIOUS LOCATION.
PROVIDE WALKWAY PADS UNDER ENTIRE SKID ASSEMBLY.
AT RIGID PENETRANTS, PROVIDE LIQUID FLASHING ASSEMBLY PER
DETAIL 9/A502. AT FLEXIBLE PENETRANTS, PROVIDE FLASHING PER
DETAIL 5/A502. CONTRACTOR TO VERIFY PENETRANT TYPES IN
FIELD AND EXTEND UTILITIES AS REQUIRED.
EXISTING TELECOM RACEWAY, AT EACH EXISTING PIPE SUPPORT
PROVIDE STRIP OF WALKWAY PAD UNDERNEATH. ADHERE STRIP
TO ROOF MEMBRANE, SEE DETAIL 4/A502, SIM.
PROVIDE REPLACEMENT BUILT-UP ROOF MEMBRANE ROOF
ASSEMBLY AT CANOPY ROOF PER DETAIL 4/A503.
PROVIDE FLASHING AT EXISTING VENT PER DETAIL 6/A502.
PROVIDE FLASHING AT EXISTING STACK / GOOSENECK VENT PER
DETAIL 3/A503.
PROVIDE MEMBRANE FLASHING AT SCUPPER PER DETAIL 2/A503.
PROVIDE ROOF DRAIN FLASHING PER DETAIL 6/A501, SIM.
ROOF KEY NOTES
A1
OPEN TO BELOW
A5
TYP
A2
A3
A4
A102 A503
TYP
A3
A3
A102 A503
TYP
A3
A1
TYP
A3
A2
TYP
4B
A102 A503 TYP
A5
A4
TYP
A102 A501 TYP, SIM
A6
A7
A8
A9
A8
A8
A9
A9
A7
A7 A6
KEY NOTE NUMBER
LEGEND:
MEMBRANE WALKPAD
(400± SF SHOWN)
RD
RD
SC
AL
E:
DA
TE
TI
ME
5- A1
1/2
1'
-0
/15
/24
:14 :15
PROJECT TITLE
REVISIONS
NO. DATE DESCRIPTION
DRAWN BY
CHECKED BY
DATE
DRAWING TITLE
DRAWING NUMBER
5-15-24
G A U T H I E R A L V A R A D O A S S O C I A T E S 703-241-2202
WWW.GAA-AE.COM
PROJECT STATUS
GAA PROJECT NO. 731E35
CONSTRUCTION DOCUMENTS
GERRY HYLAND
ROOF AND HVAC
ALTERATIONS
© COPYRIGHT ALL RIGHTS RESERVED
THESE DRAWINGS ARE PROTECTED UNDER THE
COPYRIGHT ACT OF 1976 AND SHALL NOT BE
REUSED WITHOUT THE WRITTEN PERMISSION OF
GAUTHIER, ALVARADO AND ASSOCIATES
05-15-24
FAIRFAX COUNTY
FACILITIES
MANAGEMENT
DEPARTMENT
Purchase Order No.
8500538935
Engineering Services, Contract No. 4400008465
ALEXANDRIA, VA
ARCHITECTURAL
A103
ENLARGED
PARTIAL ROOF PLAN
DAP
KLS
ENLARGED PARTIAL ROOF PLAN
1/2" = 1'-0"
1' 0 2' 4'
1/2" = 1'-0"
KEY NOTE NUMBER
LEGEND:
NEW MECHANICAL EQUIPMENT PER MEP DRAWINGS. PROVIDE FLASHING AND EQUIPMENT
SUPPORT CURB ASSEMBLY PER DETAIL 12/A502. BOTTOM OF MECHANICAL UNIT SHALL BE 18"
ABOVE T/O ROOF CAP SHEET, UON.
NEW EQUIPMENT PLATFORM, SEE DETAILS 10 & 11/A502.
PROVIDE FLASHING AND CURB ASSEMBLY FOR DUCTS SUPPORTS PER DETAIL 3/A502.
LOCATE AS REQUIRED.
PROVIDE DUCT WRAP, FLASHING AND CURB ASSEMBLY PER DETAIL 2/A502. SEE MECHANICAL
DRAWINGS FOR DUCT INFORMATION.
PROVIDE WALKWAY PAD FROM BUR MEMBRANE MFR, LOCATE AS INDICATED.
ACCESS PLATFORM AND AIR HANDLER UNIT SUPPORT FRAMING, SEE STRUCTURAL
DRAWINGS.
AT RIGID PENETRANTS, PROVIDE LIQUID FLASHING ASSEMBLY PER DETAIL 9/A502. AT
FLEXIBLE PENETRANTS, PROVIDE FLASHING PER DETAIL 5/A502. CONTRACTOR TO VERIFY
PENETRANT TYPES IN FIELD AND EXTEND UTILITIES AS REQUIRED.
PROVIDE PIPE PENETRATION SEAL ASSEMBLY PER DETAIL 3/A503.
PROVIDE PIPE SUPPORTS FOR ANY NEW PIPE RUNS PER DETAIL 4/A502. SEE MEP DRAWINGS
FOR PIPING INFORMATION.
NOT USED
PROVIDE ROOF DRAIN FLASHING ASSEMBLY PER DETAIL 6/A501.
AIR HANDLER UNIT PER MECHANICAL DRAWINGS.
NEW WORK KEY NOTES
1. THIS PLAN IS NOT A COMPLETE REPRESENTATION OF ALL THE EXISTING CONDITIONS. THIS PLAN IS SCHEMATIC IN NATURE AND INTENDS TO SHOW THE GENERAL EXTENT AND LAYOUT
OF THE EXISTING FACILITY.
2. CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL TRADES DURING CONSTRUCTION. CONTRACTOR SHALL REVIEW ALL TRADES FOR ANY MISCELLANEOUS WORK NOT SHOWN ON
ARCHITECTURAL DRAWINGS TO PROVIDE A 100% COMPLETE PROJECT.
3. PROVIDE REPLACEMENT ROOF ASSEMBLY. TUCK MEMBRANES UNDER EXISTING METAL FLASHING THROUGHOUT ENTIRE ROOF. MATCH DOCUMENTED SLOPES, CRICKETS, AND SUMPS TO
MATCH EXISTING ROOF. SEE DETAIL 1/A501 FOR TYPICAL ROOF MEMBRANE ASSEMBLY NOTES.
4. PROTECT EXISTING EQUIPMENT TO REMAIN DURING CONSTRUCTION INCLUDING MECHANICAL UNITS, DUCTING, PIPES, VENTS, PLATFORMS, ETC.
5. IF EXISTING EQUIPMENT DESIGNATED TO REMAIN IS DAMAGED AS A RESULT OF CONSTRUCTION, CONTRACTOR IS RESPONSIBLE FOR REPAIR OR REPLACEMENT.
6. CONTRACTOR TO REPAIR AND RE-CERTIFY EXISTING LIGHTNING PROTECTION SYSTEM.
7. CONTRACTOR TO SCAN ALL PROSPECTIVE SLAB DRILL LOCATIONS BY MEANS OF DIGITAL X-RAY OR GPR IMAGING TO VERIFY THAT THERE ARE NO CONFLICTS. CONTRACTOR TO ADJUST CORE DRILL LOCATIONS AS REQUIRED. BUILDING IS CONSTRUCTED WITH REINFORCED CONCRETE POST-TENSION SLABS. NO SLAB TENDONS SHALL BE CUT.
GENERAL PLAN NOTES
A103 A501
TYP
SIM, TYP
30" CLR ABOVE CAP SHEET
A103 A502
A103 A502
A103 A502
A103 A502
TYP
5 5
A103 A502
EXISTING CHILLER TOWER EXISTING CHILLER TOWER EXISTING CHILLER TOWEREXISTING FRAMING
EXISTING LADDER
AND REQ CLR, TYP
EXISTING LADDER TO PENTHOUSE ROOF
PLATFORM LADDER
REQ CLR
30"
MEMBRANE WALKPAD
RD
2B
2C
2A
B B
B.4
C C
A103 A501
SC
AL
E:
DA
TE
TI
ME
5- A1
1/4
1'
-0
/15
/24
:14 :14
1. THIS PLAN IS NOT A COMPLETE REPRESENTATION OF ALL THE EXISTING
CONDITIONS. THIS PLAN IS SCHEMATIC IN NATURE AND INTENDS TO SHOW THE
GENERAL EXTENT AND LAYOUT OF THE EXISTING FACILITY.
2. CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL TRADES DURING
CONSTRUCTION. CONTRACTOR SHALL REVIEW ALL TRADES FOR ANY
MISCELLANEOUS WORK NOT SHOWN ON ARCHITECTURAL DRAWINGS TO PROVIDE
A 100% COMPLETE PROJECT.
3. FIELD VERIFY EXISTING CONDITIONS. IF A CONDITION IS NOT INDICATED ON
DRAWINGS AND IS NOT SIMILAR TO OTHER DETAILED CONDITIONS, DOCUMENT
AND SUBMIT AND RFI FOR A/E DIRECTION.
4. REMOVE INDICATED EXISTING CONSTRUCTION CLEANLY AND LEAVE EXISTING
CONSTRUCTION TO REMAIN READY TO RECEIVE NEW WORK.
5. REMOVE EXISTING CONSTRUCTION, INCLUDING MECHANICAL, PLUMBING,
ELECTRICAL WORK ETC., AS NECESSARY AND WHEREEVER NECESSARY TO
PROVIDE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
6. PROTECT EXISTING EQUIPMENT TO REMAIN DURING CONSTRUCTION INCLUDING
MECHANICAL UNITS, DUCTS, PIPES, LIGHT FIXTURES, ETC.
7. IF EXISTING EQUIPMENT ADJACENT TO CONSTRUCTION IS DAMAGED AS A RESULT
OF CONSTRUCTION WORK, CONTRACTOR IS RESPONSIBLE FOR REPAIR OR
REPLACEMENT.
8. ANY REQUIRED UTILITY SHUT-OFF WILL BE COORDINATED WITH OWNER.
9. CONTRACTOR TO SCAN ALL PROSPECTIVE SLAB DRILL LOCATIONS BY MEANS OF
DIGITAL X-RAY OR GPR IMAGING TO VERIFY THAT THERE ARE NO CONFLICTS.
CONTRACTOR TO ADJUST CORE DRILL LOCATIONS AS REQUIRED. BUILDING IS
CONSTRUCTED WITH REINFORCED CONCRETE POST-TENSION SLABS. NO SLAB
TENDONS SHALL BE CUT.
10. CONTRACTOR TO VERIFY IN FIELD EXISTING , 5TH FLOOR, ABOVE CEILING
CONSTRUCTION AND ADJUST LOCATIONS OF PENETRATIONS AND PIPING RUNS
AS REQUIRED.
GENERAL NOTES
PROVIDE TEMPORARY PROTECTION FOR ITEMS IN AREA OF WORK.
AREA OF CEILING GRID/TILE TO REMOVED FOR INSTALLATION OF STEEL
BEAMS. COORDINATE AMOUNT OF CEILING AREA WITH REQUIRED MEANS
AND METHODS FOR INSTALLING ADDED STRUCTURE. PROTECT FOR
REINSTALLATION.
INDEPENDENTLY HANG LIGHT, PROTECT AND MAINTAIN OPERATIONAL.
MAINTAIN ALL EMERGENCY LIGHT CIRCUITS.
CONTRACTOR TO PROTECT ALL SPRINKLER LINES/HEADS IN AREA OF WORK.
MAINTAIN SPRINKLER SYSTEM IN WORKING ORDER. PROVIDE FIRE WATCH
AS NEEDED WHILE TILE/GRID IS NOT INSTALLED.
CONTRACTOR TO SUPPORT OCCUPANCY SENSOR, MAINTAIN OPERATION.
CONTRACTOR TO REHANG DATA, EMC ABOVE CEILING AS REQUIRED FOR
STEEL INSTALLATION.
CONTRACTOR TO TEMPORARILY SUPPORT EXISTING SUPPLY DIFFUSERS.
REINSTALL GRID/TILE AFTER INSTALLATION OF STEEL.
RESEAT ALL LIGHTS IN GRID.
CONTRACTOR TO REINSTALL SPRINKLER ESCUTEON'S.
CONTRACTOR TO REINSTALL OCCUPANCY SENSOR.
CONTRACTOR TO REINSTALL SUPPLY/RETURN DIFFUSERS.
CONTRACTOR TO MAINTAIN ANY MECHANICAL SUPPLY AND RETURN
DUCTWORK, CONNECT TO NEW UNIT, SEE MECHANICAL DRAWINGS.
KEY NOTES
5TH FLOOR
DEMOLITION REFLECTED CEILING PLAN
1/4" = 1'-0"
5' 3' 1' 0 5'
1/4" = 1'-0"
2' x 4' SUSPENDED
ACOUSTICAL PANEL CEILING
CEILING HEIGHT ABOVE
FINISH FLOOR, SEE FINISH
SCHEDULE FOR SPACES
NOT INDICATED
LIGHT FIXTURES,
SEE ELEC DWGS
RCP LEGEND:
EXISTING 2' x 2' SUSPENDED
ACOUSTICAL PANEL CEILING
EXIST
HVAC DIFFUSER,
SEE MECH DWGS
TYP
TYP
D
C
7 TYP
EXIST
PROJECT TITLE
REVISIONS
NO. DATE DESCRIPTION
DRAWN BY
CHECKED BY
DATE
DRAWING TITLE
DRAWING NUMBER
5-15-24
G A U T H I E R A L V A R A D O A S S O C I A T E S 703-241-2202
WWW.GAA-AE.COM
PROJECT STATUS
GAA PROJECT NO. 731E35
CONSTRUCTION DOCUMENTS
GERRY HYLAND
ROOF AND HVAC
ALTERATIONS
© COPYRIGHT ALL RIGHTS RESERVED
THESE DRAWINGS ARE PROTECTED UNDER THE
COPYRIGHT ACT OF 1976 AND SHALL NOT BE
REUSED WITHOUT THE WRITTEN PERMISSION OF
GAUTHIER, ALVARADO AND ASSOCIATES
05-15-24
FAIRFAX COUNTY
FACILITIES
MANAGEMENT
DEPARTMENT
Purchase Order No.
8500538935
Engineering Services, Contract No. 4400008465
ALEXANDRIA, VA
ARCHITECTURAL
A104
5TH FLOOR
REFLECTED CEILING PLANS
KLS
KLS
BUILDING CORE KEY PLAN
AREA OF WORK
THIS PLAN IS NOT A COMPLETE REPRESENTATION OF ALL THE EXISTING
CONDITIONS. THIS PLAN IS SCHEMATIC IN NATURE AND INTENDS TO SHOW THE
GENERAL EXTENT AND LAYOUT OF THE EXISTING FACILITY.
CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL TRADES DURING
CONSTRUCTION. CONTRACTOR SHALL REVIEW ALL TRADES FOR ANY
MISCELLANEOUS WORK NOT SHOWN ON ARCHITECTURAL DRAWINGS TO PROVIDE
FIELD VERIFY EXISTING CONDITIONS. IF A CONDITION IS NOT INDICATED ON
DRAWINGS AND IS NOT SIMILAR TO OTHER DETAILED CONDITIONS, DOCUMENT
REMOVE INDICATED EXISTING CONSTRUCTION CLEANLY AND LEAVE EXISTING
CONSTRUCTION TO REMAIN READY TO RECEIVE NEW WORK.
REMOVE EXISTING CONSTRUCTION, INCLUDING MECHANICAL, PLUMBING,
ELECTRICAL WORK ETC., AS NECESSARY AND WHEREEVER NECESSARY TO
PROVIDE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
PROTECT EXISTING EQUIPMENT TO REMAIN DURING CONSTRUCTION INCLUDING
MECHANICAL UNITS, DUCTS, PIPES, LIGHT FIXTURES, ETC.
IF EXISTING EQUIPMENT ADJACENT TO CONSTRUCTION IS DAMAGED AS A RESULT
OF CONSTRUCTION WORK, CONTRACTOR IS RESPONSIBLE FOR REPAIR OR
ANY REQUIRED UTILITY SHUT-OFF WILL BE COORDINATED WITH OWNER.
CONTRACTOR TO SCAN ALL PROSPECTIVE SLAB DRILL LOCATIONS BY MEANS OF
DIGITAL X-RAY OR GPR IMAGING TO VERIFY THAT THERE ARE NO CONFLICTS.
CONTRACTOR TO ADJUST CORE DRILL LOCATIONS AS REQUIRED. BUILDING IS
CONSTRUCTED WITH REINFORCED CONCRETE POST-TENSION SLABS. NO SLAB
CONTRACTOR TO VERIFY IN FIELD EXISTING , 5TH FLOOR, ABOVE CEILING
CONSTRUCTION AND ADJUST LOCATIONS OF PENETRATIONS AND PIPING RUNS
PROVIDE TEMPORARY PROTECTION FOR ITEMS IN AREA OF WORK.
AREA OF CEILING GRID/TILE TO REMOVED FOR INSTALLATION OF STEEL
BEAMS. COORDINATE AMOUNT OF CEILING AREA WITH REQUIRED MEANS
AND METHODS FOR INSTALLING ADDED STRUCTURE. PROTECT FOR
INDEPENDENTLY HANG LIGHT, PROTECT AND MAINTAIN OPERATIONAL.
CONTRACTOR TO PROTECT ALL SPRINKLER LINES/HEADS IN AREA OF WORK.
MAINTAIN SPRINKLER SYSTEM IN WORKING ORDER. PROVIDE FIRE WATCH
AS NEEDED WHILE TILE/GRID IS NOT INSTALLED.
CONTRACTOR TO SUPPORT OCCUPANCY SENSOR, MAINTAIN OPERATION.
CONTRACTOR TO REHANG DATA, EMC ABOVE CEILING AS REQUIRED FOR
CONTRACTOR TO TEMPORARILY SUPPORT EXISTING SUPPLY DIFFUSERS.
REINSTALL GRID/TILE AFTER INSTALLATION OF STEEL.
CONTRACTOR TO REINSTALL SPRINKLER ESCUTEON'S.
CONTRACTOR TO REINSTALL OCCUPANCY SENSOR.
CONTRACTOR TO REINSTALL SUPPLY/RETURN DIFFUSERS.
CONTRACTOR TO MAINTAIN ANY MECHANICAL SUPPLY AND RETURN
DUCTWORK, CONNECT TO NEW UNIT, SEE MECHANICAL DRAWINGS.
PARTITION / CONSTRUCTION TO REMAIN
DOOR AND FRAME TO REMAIN
REMOVE PARTITION / CONSTRUCTION
REMOVE DOOR AND FRAME
REMOVE PARTITION, DOOR AND FRAME
KEY NOTE NUMBER
ROOM DESIGNATION
ROOM NUMBER
FLOOR PLAN LEGEND:
LOBBY
2 HR FIRE ASSEMBLY
5TH FLOOR MECHANICAL ROOM
FLOOR PLAN
1/4" = 1'-0"
5' 3' 1' 0 5'
1/4" = 1'-0"
D
C
TYP
TYP
11 12 TYP
SC
AL
E:
DA
TE
TI
ME
5- A5
1-
1/2
1' -0
/15 /24
:14
:13
PROJECT TITLE
REVISIONS
NO. DATE DESCRIPTION
DRAWN BY
CHECKED BY
DATE
DRAWING TITLE
DRAWING NUMBER
5-15-24
G A U T H I E R A L V A R A D O A S S O C I A T E S 703-241-2202
WWW.GAA-AE.COM
PROJECT STATUS
GAA PROJECT NO. 731E35
CONSTRUCTION DOCUMENTS
GERRY HYLAND
ROOF AND HVAC
ALTERATIONS
© COPYRIGHT ALL RIGHTS RESERVED
THESE DRAWINGS ARE PROTECTED UNDER THE
COPYRIGHT ACT OF 1976 AND SHALL NOT BE
REUSED WITHOUT THE WRITTEN PERMISSION OF
GAUTHIER, ALVARADO AND ASSOCIATES
05-15-24
1 04-03-2024 RTU-1 CHANGES
FAIRFAX COUNTY
FACILITIES
MANAGEMENT
DEPARTMENT
Purchase Order No.
8500538935
Engineering Services, Contract No. 4400008465
ALEXANDRIA, VA
2 04-30-2024 PERMIT SUBMISSION
ARCHITECTURAL
A501
DETAILS
DAP
KLS
PARAPET DETAIL (TYPICAL ROOFING DETAIL NOTES)
1-1/2" = 1'-0"
D101 A101
A501
LOWER ROOF SCUPPER DETAIL
1-1/2" = 1'-0"
D101 A101
A501
DEMOLITION
EXISTING PARAPET METAL FLASHING,
DISASSEMBLE AND SALVAGE FOR
REMOVE BUR MEMBRANE
FLASHING
REMOVE EXISTING BALLAST
EXISTING SLOPED CONCRETE SLAB
REMOVE RIGID INSULATION
REMOVE ALL BUR PLIES
REMOVE CANT STRIPS
EXISTING PREFAB CONC
PARAPET ASSEMBLY
EXISTING CONCRETE CURB
6" 4"
REASSEMBLE AND REINSTALL
TUCK BASE AND MEMBRANE
FASTENERS SET IN SEALANT, 8" OC
PREP ALL EXISTING SURFACES
TO RECEIVE NEW WORK PER
ROOFING MANUFACTURER
REQUIREMENTS
MEMBRANE BASE FLASHING
EXISTING METAL PARAPET
FLASHING ASSEMBLY BEYOND, SEE DETAIL 1/A501
EXISTING MTL DRIP TO REMAIN
EXISTING METAL SCUPPER FLASHING TO REMAIN
BASE FLASHINGREMOVE GRAVEL STOP
NEW WORK
TO METAL DRIP
TERMINATE CAPSHEET
FLASHING TO DRIP
EDGE AND
SET IN SEALANT
PARAPET BASE FLASHING BEYOND,
ALIGN MEMBRANE
SEE DETAIL 1/A501
DEMOLITION NEW WORK
ROOF DRAIN DETAIL
1-1/2" = 1'-0"
REMOVE FLASHING CLAMP & GRAVEL STOP
REMOVE DRAIN STRAINER
D101 A101
A501
2 LAYERS STRIPPING FELT EXTEND 4" & 8" BEYOND FLASHING,
30" SQ MIN 2-1/2 LB LEAD FLASHING
FLASHING CLAMP & GRAVEL STOP
PROVIDE NEW STRAINER AND CLAMP RING ASSEMBLY
EXTEND ROOFING APPROX 1" BEYOND INSIDE OF CLAMPING RING
EXISTING DRAIN BODY EMBEDDED
EXISTING DRAIN LEADER
TO REMAIN
SET IN ROOFING CEMENT
IN CONC, ASSEMBLY TO REMAIN
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
DEMOLITION NEW WORK
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
FLASHING AT PENTHOUSE WALL
1-1/2" = 1'-0"
D101 A101
A501
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
DEMOLITION
EXISTING METAL FLASHING
W/ CLEAT TO REMAIN
EXISTING EFIS WALL
FASTENERS SET IN
SEALANT, 8" OC
NEW WORK
6" 4" 8" M
IN
FL
AS
HI
NG
H
T
TUCK BASE AND MEMBRANE
UNDER EXISTING METAL FLASHING
8" M
IN
FL
AS
HI
NG
H
T
FLASHING AT SCREEN WALL COLUMN
1-1/2" = 1'-0"
D101 A101
A501
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
DEMOLITION NEW WORK
EXISTING SHEET METAL
EXISTING TUBE STEEL
EXISTING CONCRETE
POST, VIF
VIF EXISTING FURRING,
REPLACE AS REQD
COLUMN ASSEMBLY,
DO NOT DISTURB
6" 4" 8" M
IN
FL
AS
HI
NG
H
T
FASTENERS SET IN
SEALANT, 8" OC
TUCK BASE AND MEMBRANE
REFER TO DETAIL 1/A501 FOR TYPICAL ROOFING NOTES
EQUIPMENT CURB DETAIL
1-1/2" = 1'-0"
D101 A101
A501
DEMOLITION NEW WORK
TUCK BASE AND MEMBRANE FLASHING UNDER
FASTENERS SET IN SEALANT, 8" OC
PREFAB CURB ADAPTER AS REQD
ROOF TOP UNIT
4" 4"
GASKET
DISASSEMBLE CURB
REMOVE EXISTING ROOF T
EXISTING EQUIPMENT
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
OP UNIT PER MECH DWGS
FLASHING AS REQUIRED
CURB TO REMAIN
PER MECH DWGS
EXISTING METAL CURB FLASHING
FLASHING UNDER EXISTING
METAL FLASHING
ASSEMBLY DO NOT DISTRUB FLASHING UNDER EXISTING
METAL FLASHING
RAIN COLLAR FLASHING
WITH SEALANT TO REMAIN
FLASHING AT CONCRETE
1-1/2" = 1'-0"
D101 A103
A501
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
DEMOLITION NEW WORK
6" 4" 8" M
IN
FL
AS
HI
NG
H
T
FACE OF EXISTING COLUMN
DISASSEMBLE AND SALVAGE
EXISTING CONT SURFACE
MOUNTED COUNTER FLASHING
FOR REINSTALLATION
DURING NEW WORK
BASE AND MEMBRANE
FLASHING UNDER REINSTALLED
METAL FLASHING
REINSTALL SALVAGED SURFACE
MOUNTED COUNTER FLASHING,
MATCH PREVIOUS DETAILSCOMPATIBLE
SEALANT
FASTENERS SET IN
SEALANT, 8" OC
CONTINUE FIELD PLYS
AND FLASHING INTO
EXISTING SCUPPER
FLASHING WITH PARAPET
6" 4"
FLASHING BEYOND1/4"
12"
ROOF FIELD TYPICAL ASSEMBLY:
MOD BIT CAP SHEET W/ 3 PLIES OF TYPE VI FULLY ADHERED TO ISO HD COVERBOARD.
RIGID POLYISO INSULATION TO MATCH EXISTING INSULATION HEIGHTS, SHALL COMPLY WITH;
- 8" MIN FLASHING HEIGHTS PER NRCA GUIDELINES
- ROOF MEMBRANE MANUFACTURER 20 YEAR NO-DOLLAR-LIMIT WARRANTY
DOCUMENT EXISTING SUMPS
CONSTRUCT SUMPS TO MATCH EXISTING
REINSTALLATION DURING NEW WORK
REMOVE PARAPET WALL JOINT SEALANTS
FROM CONC DECK - TO - T/O PARAPET WALL,
PREPARE SURFACES FOR NEW WORK
EXTENT OF SEALANT REMOVAL
EXISTING PARAPET METAL FLASHING
PROVIDE NEW PARAPET WALL
JOINT SEALANT FROM
CONC DECK - TO - T/O PARAPET WALL
SC
AL
E:
DA
TE
TI
ME
5- A5
1-
1/2
1' -0
/15 /24
:14
:13
PROJECT TITLE
REVISIONS
NO. DATE DESCRIPTION
DRAWN BY
CHECKED BY
DATE
DRAWING TITLE
DRAWING NUMBER
5-15-24
G A U T H I E R A L V A R A D O A S S O C I A T E S 703-241-2202
WWW.GAA-AE.COM
PROJECT STATUS
GAA PROJECT NO. 731E35
CONSTRUCTION DOCUMENTS
GERRY HYLAND
ROOF AND HVAC
ALTERATIONS
© COPYRIGHT ALL RIGHTS RESERVED
THESE DRAWINGS ARE PROTECTED UNDER THE
COPYRIGHT ACT OF 1976 AND SHALL NOT BE
REUSED WITHOUT THE WRITTEN PERMISSION OF
GAUTHIER, ALVARADO AND ASSOCIATES
05-15-24
1 04-03-2024 RTU-1 CHANGES
FAIRFAX COUNTY
FACILITIES
MANAGEMENT
DEPARTMENT
Purchase Order No.
8500538935
Engineering Services, Contract No. 4400008465
ALEXANDRIA, VA
2 04-30-2024 PERMIT SUBMISSION
ARCHITECTURAL
A502
DETAILS
DAP
KLS
SLED POST FLASHING DETAIL
1-1/2" = 1'-0"
3'- 0"
VI
F
A101 A502
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
TRTD 2x WD BLKG
" M
IN
EQUIPMENT SUPPORT AS REQUIRED
2x4 TRTD WD BLKG, MATCH HEIGHT OF INSUL
SET BOLTS IN SEALANT
METAL COVER W/ REMOVABLE
COUNTER FLASHING
CONTINUOUS WATERPROOF
MEMBRANE OVER CURB
BASE FLASHING
4" 4"
REFER TO DETAIL 1/A501 FOR TYPICAL ROOFING NOTES
EQUIPMENT SUPPORT DETAIL
1-1/2" = 1'-0"
A101 A103
A502
DUCT THRU ROOF DETAIL
1-1/2" = 1'-0"
8" M
IN
3"
GASKETED FASTENERS @ 24" OC,
MIN TWO PER SIDE
CONTINUOUS WATERPROOF
MEMBRANE OVER CURB
BASE FLASHING
4" 4"
EXIST CONC SLAB OPENING
2x4 TRTD WD BLKG,FILL GAP AROUND
CONT 16 GA GALV STEEL
CURB W/ INSUL
DUCT W/ INSULATION
SHEET METAL FLASHING COLLAR,
WELD ALL JOINTS
SST CLAMPING RING SET
IN BED OF SEALANT
MEMBRANE WRAPPED
DUCT, SEE MECH DWGS
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
A103 A502
INFILL VOIDS AROUND FRAMING
WITH RIGID INSUL SET IN COMPATIBLE
ADHESIVE TO MATCH EXISTING
6 1 /2"
1'-0 1/2"± 8"±
THERMOPLASTIC
16 GAUGE GALVANIZED
CADDY PYRAMID ST SERIES, MANUFACTURED
BASE
STEEL STRUT
PIPE SUPPORT DETAIL
1-1/2" = 1'-0"
PIPE, SEE MECH DWGS
GALVANIZED
PIPE CLAMP
PIPE SUPPORT - BASIS OF DESIGN: PROVIDE WALKWAY
PAD COMPATIBLE WITH
ROOFING AT EACH PIPEBY NVENT, ADHERE TO WALKWAY PAD WITH
SUPPORTCOMPATIBLE ADHESIVE
A101 A103
A502
VENT THRU ROOF DETAIL
1-1/2" = 1'-0"
WATER CUT-OFF MASTIC
6" 4" 4"
2 LAYERS STRIPPING FELT
LEAD PIPE FLASHING,
D101 D102 A101
A502
EXISTING VENT
REMOVE EXISTING
DEMOLITION
NEW WORK
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
LAP INSIDE PIPE 1" MIN
PIPE TO REMAIN
A102
FI
LE
SC
AL
E:
DA
TE
TI
ME
5- A5
-D
1/2
1'
-0
/03
/24
:55 :4
SIDE RAILS,
EQUIPMENT PLATFORM
RAILING AND LADDER DETAILS
1/2" = 1'-0"
REMOVABLE
GUARDRAIL
8"
SECTION @
2'-0"
1'-6"
2'-6"
2" 1'-
0"
RUNGS - 3/4"Ø STL BARS
EQUALLY SPACED 12" MAX
ELEVATION
@ LADDER
OC, WELD TO SIDE RAILS
SEE STRUCTURAL
A103 A502
ROOF MEMBRANE
GALV
SERRATED
ENLARGED PLAN
EQUIPMENT PLATFORM
1/2" = 1'-0"
A103 A502
MAU SEE
MECHANICAL
PERMANENT
CONT 1", TYP
GALVANIZED SERRATED
STEEL GRATING, TYP
DRAWINGS
1' 0 2' 4'
1/2" = 1'-0"
1' 0 2' 4'
1/2" = 1'-0"
10'-0"
3'- 6"
5'- 0"
3'-10"
EQ
UA
L
TYP GUARDRAIL
PROVIDE RADIUS
AT TURN DOWNS, TYP
GUARDRAIL
3'- 0"
3'-2"
EQ
UA
L x x x x x
REMOVABLE
GUARDRAIL
FRAMING PER STRUCTURAL DRAWINGS.
COORDINATE FINAL PLATFORM SIZE AND
LAYOUT WITH PURCHASED MAKEUP AIR UNIT.
A502 A502
6"
STEEL
GRATING
V
IF
FOR ATTACHMENTS
TO SIDE RAILS
1'- 0"
TY
P
GUARDRAIL
BEYOND
EQ
EQPL 3/8 x 2-1/2
DRILLED FOR RUNGS
WELD ALL
CONNECTIONS
AND GRIND EDGES
SMOOTH, TYP.
COORDINATE WITH
STRUCTURAL
DRAWINGS
ELEVATION - NTS
2.5 STD PIPE SLEEVE TO
4"
CONT 1/4" PL
4"
RECEIVE GUARDRAIL
RAILS & POSTS,
PIPE 2 STD
SECTION @
PERMANENT
GUARDRAIL
5'-4"
2'-6"
PERMANENT
GUARDRAIL
4"
CLR
MAX, T
YP
4" C
LR
M
AX
, T
YP
1/2" Ø GALV CHAIN W/ CHAIN BOLT SNAP ON
ENDS. INSTALL SCREW EYE HOOKS IN POSTS
FOR CONNECTION TO BOLT SNAP
4'- 7"
" M
IN
NEW CONSTRUCTION SHALL PROVIDE 10" MIN PIPE FLASHING
HEIGHT. PROVIDE VENT PIPE EXTENSION AS REQUIRED.
PENETRATION BOX DETAIL
1-1/2" = 1'-0"
8" M
IN 3"
M
IN
BASE FLASHING
TRTD WD CURB
2x4 TRTD WD BLKG, MATCH HEIGHT OF INSUL
4" 4"
SAFETY TIE OFF ANCHOR
FLASHING DETAIL
1-1/2" = 1'-0"
A101 A502
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
FLEXIBLE CABLE / CONDUIT
PENETRATION DETAIL
1-1/2" = 1'-0"
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
D101 D102 A101
A502
A102
1'- 0"
M
IN
6" 4" 4"
RADIUS AS REQD
WATER CUT-OFF MASTIC
2 LAYERS OF STRIPPING
FELT
EXTEND UTILITIES
AS REQUIRED
IF NOT PRESENT, PROVIDE
CONDUIT TO ROOF DECK
A101 A502
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
1"
MIN
1" MIN
VARIES, VIF
INFILL SPACE BTWN CURBS
WITH MINERAL WOOL INSUL
EXISTING
PENETRANT, VIF
SEALANT
WEATHERPROOF
SHEET-METAL RAIN
1" OVERLAP MIN,
SET IN SEALANT
RAIN COLLAR SECTIONS
MECH FASTENED AND SEALED
COUNTER FLASHING
PERSPECTIVE VIEW - NTS
SINGLE RIGID
PIPE/CABLE PENETRATION
1-1/2" = 1'-0"
A101 A102 A103
A502
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
4" M
IN
4" MIN
SEALANT
REINFORCED
LIQUID FLASHING
EXTEND EXISTING
PENETRANT AS REQ TO
MEET MIN FLASHING
HEIGHTS, VIF
EXISTING VENT PIPE
PIPE FLASHING
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
TIE-INTO EXISTING
DUCT PENETRATION
ASSEMBLY
MAINTAIN EXISTING CONC
BELOW MEMBRANE
STAINLESS STL
FLANGED GOOSENECK
CABLE FLASHING
REINFORCED LIQUID FLASHING
PER ROOF MEMBRANE MFR
REQUIREMENTS
ANCHOR HOOK SHALL
REMAIN UNCOVERED
DUCT INSULATION
MATCH HEIGHT OF INSUL
DECK PENETRATION ASSEMBLY,
DUCTS, SEE MECH DWGS
MEMBRANE WRAPPED
8"
VI
F
RIGID POLYISO BETWEEN
MEMBRANE ON
DUCTS, CUT TO SLOPE
FOR POSITIVE DRAINAGE
2x4 FRT TRTD WD BLKG
ATTACHED TO CURB
FILL GAP BETWEEN
DUCT INSULATION
SLOPED POLYISO
DUCTS W/ INSULATION
SECTION THROUGH
DUCT GAP
SECTION THOUGH
SLOPED POLYISO AND CURB
1/2" 12"
MIN
INFILL GAP UNDER
COLLAR WITH POLYISO
EXTEND MEMBRANE
OVER INSUL
FRT TRD WD NAILER
AS REQ FOR CONT
SHEET METAL
FLASHING COLLAR
EDGE OF MEMBRANE
WRAPPED DUCT
INSULATION BEYOND
REPAIR AS REQUIRED
BENT PL BRACKET
EXHAUST FAN SUPPORT DETAIL
1-1/2" = 1'-0"
A101 A103
A502
6" 4" 2" 0 6" 1'
1-1/2" = 1'-0"
TRTD 2x WD BLKG
" M
IN
2x4 TRTD WD BLKG, MATCH HEIGHT OF INSUL
BASE FLASHING
4" 4"
INFILL VOIDS AROUND FRAMING
WITH RIGID INSUL SET IN COMPATIBLE
ADHESIVE TO MATCH EXISTING
METAL COVER W/ REMOVABLE
COUNTER FLASHING
CONTINUOUS WATERPROOF
MEMBRANE OVER CURB
VARIES
COORDINATE W/ PURCHASED EQUIPMENT
VA
RI
ES
CO
OR
DI
NA
TE
W / P
UR
CH
AS
ED
E
QU
IP
ME
NT
SE
E
RO
OF
P
LA
N
CRICKET BETWEEN WOOD
CURBS FOR POSITIVE DRAINAGE
SET BOLTS IN SEALANT
GALV STL BENT PLATE
BRACKET AT POSTS
GALV STL L 3 1/2 x 3 1/2 x 1/4"
GALV STL BASE PLATE
CONTINUOUS, GALV STL
L 3 1/2 x 3 1/2 x 1/4" FRAME
EXHAUST FAN
1/2" 12"
MIN
POST AT EACH CORNER
2A 2B
2C
TYP
3/16
MAX 5'-0" SPAN
COLLAR, OVERLAP
CURB COUNTER
FLASHING WITH SEALANT
EXIST STRUCTURAL
FR…
This is the start of the file's text. The full file is on GovTribe.