This document is a voltage drop and cable schedule for an excavator barge. It provides specifications for an electrical distribution system, including generator power, shore power connections, switchboards, panels, motors, lighting, and other equipment. Key details include specifications for circuits at 480V and 208/120V three-phase and single-phase, with amperages ranging from 1 to 259 amps and cable sizes from 2.1mm2 to 350mm2. Over 30 equipment items are specified across multiple switchboards and panels, including generators, pumps, fans, controls, and receptacles. Voltage drop calculations are provided for each circuit based on cable size and length to ensure voltage levels are maintained within acceptable tolerances. This level of engineering design is necessary to properly power all electrical systems and equipment for safe and reliable operation of the excavator barge.

View the file

Other files for this federal contract opportunity

Other files attached to Excavator Barge, newest first.
File Type Posted
W912BU-23-B-0024 Amendment 2.pdf PDF
W912BU-23-B-0024 Amendment 1.pdf PDF
W912BU-23-B-0024.pdf PDF
871-B690-01 Compressed Air.pdf PDF
871-B552-01 Spudwell Structure and Spud Handling Sys.pdf PDF
871-B637-01 Waste Oil System.pdf PDF
871-B427-01 Vertical and Inclined Ladders.pdf PDF
871-B415-01 Doors Windows Hatches and Manholes.pdf PDF
871-B309-01 Transverse Structure.pdf PDF
871-B305-01 Scantling Plan.pdf PDF
871-B307-01 Shell Plating.pdf PDF
871-B405-01 Cathodic Protection.pdf PDF
871-B115-01 WEIGHT ESTIMATES.pdf PDF
871-B205-01 PROFILE.pdf PDF
871-B000-02 Drawing Index.pdf PDF
731-E170-01 DRY DOCKING PLAN.pdf PDF
871-B670-01 Vents Sounds Overflows and Fills.pdf PDF
871-B672-01 Drainage System.pdf PDF
871-B720-02 DC One-Line Diagram.pdf PDF
871-B665-01 Potable Water System.pdf PDF
871-B630-01 Fuel Oil System.pdf PDF
871-B410-01 Fendering Details.pdf PDF
871-B399-01 ABS Structure Calculations.pdf PDF
871-B325-01 Seachest Details.pdf PDF
871-B215-01 General Arrangement.pdf PDF
871-B311-01 Longitudinal Structure.pdf PDF
871-B150-01 DAMAGE STABILITY.pdf PDF
703-B725-03 REV- EMERGENCY LIGHTING VOLTAGE DROP AND CABLE SCHEDULE.pdf PDF
871-B760-01 Shore Power and Off-Vessel Power Details.pdf PDF
871-B720-01 Rev A AC One-Line.pdf PDF
871-B710-02 Rev A AC Load Analysis.pdf PDF
871-B667-01 Sewage System.pdf PDF
871-B445-01 Rev A Lifesaving Safety Plan.pdf PDF
871-B635-01 Lube Oil System.pdf PDF
871-B550-01 Spud Contructon Details.pdf PDF
871-B601-01 Pipe Marking Guide.pdf PDF
871-B315-01 Deck House Structure.pdf PDF
871-B320-01 Independent Tanks Details.pdf PDF
871-B130-01 TANK CAPACITY.pdf PDF
871-B125-01 HYDROSTATICS.pdf PDF
871-B105-01 Lines Plan.pdf PDF
793-B685-04 MACHINERY SPACE HEATING AND COOLING LOAD CALCULATIONS.pdf PDF
793 SAMPLE PLACARD.pdf PDF
703-B685-03 REV- HOT WATER CIRCULATING SYSTEM.pdf PDF
871-B730-03 DC SYS AND E-Lighting.pdf PDF
871-B460-01 HULL MARKINGS.pdf PDF
871-B720-02 DC One Line Diagram.pdf PDF
T1716010 KEEN Stability Letter - signed with Load Charts_106379386.pdf PDF
871-B730-01 Lighting Plan.pdf PDF
871-B730-02 Receptacle Plan.pdf PDF
Show all 50

Excavator Barge has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REV. DATE APRD.

- 10/15/2021

□ Accepted

□ Accepted with Comments

□ Not Accepted

Refer to Notations On:

□ Drawing

□ Return Document

Resubmission: □ Required □ Not Required

Approved Subj. to Approv. Reg. Agcy. Apprvl.

Reviewer:

Date Returned:

Return Document No.:

General Notes:

DR. BY DES. BY CHK'D BY

CJM CJM SNT

APRD. FOR THE DIR. - CH. DES. BR. SIZE REV.

DATE

SHEET: COVER

/ / TIMOTHY KEYSER

A 3218 871-B725-01 -

Oct-21 SCALE: NTS

ST. PAUL DISTRICT- EXCAVATOR BARGE

150' X 40' X 9'

VOLTAGE DROP AND CABLE SCHEDULERECOMMENDED

/ / RYAN IMMEL

PROJECT NO. DRAWING NO.

MDC REVIEW

MARINE DESIGN

CENTER

100 PENN SQUARE EAST

DEPARTMENT OF THE ARMY

MARINE DESIGN CENTER

CORPS OF ENGINEERS

REVISIONS

DESCRIPTION

Original Issue

SWITCHBOARD CIRCUIT

480V NUMBER V PH A SIZE CM FEET VD V% Total V%

FROM GEN-1 TO SWITCHBOARD GEN-1 480 3 188 F-350 350000 34 0.41 0.09 0.09

FROM GEN-2 TO SWITCHBOARD GEN-2 480 3 188 F-350 350000 54 0.65 0.14 0.14

FROM GEN-3 TO SWITCHBOARD GEN-3 480 3 75 F-350 350000 46 0.22 0.05 0.05

FROM PORT SHORE POWER REC. TO ISO XMFR SPTP-1 480 3 150 F-83 83700 42 1.68 0.35 0.35

FROM STBD SHORE POWER REC. TO ISO XMFR SPTP-2 480 3 150 F-83 83700 26 1.04 0.22 0.22

FROM ISO XMFR NO.1 TO DISCONNECT SPTS-1 480 3 150 F-83 83700 10 0.40 0.08 0.08

FROM ISO XMFR NO.2 TO DISCONNECT SPTS-2 480 3 150 F-83 83700 10 0.40 0.08 0.08

FROM ISO XMFR DISCONNECT TO SWITCHBOARD SPTS-2A 480 3 150 F-350 350000 8 0.08 0.02 0.02

THREE PHASE VD=(1.732KxLxI)/Cm K=12.9 FOR Cu

AC VOLTAGE DROP CALCULATIONS

3218 - MVP CRAWLER CRANE BARGE

VOLTAGE DROP EQUATIONS

SINGLE PHASE VD=(2KxLxI)/Cm K=12.9 FOR Cu

SWITCHBOARD DISTRIBUTION BUS CIRCUIT

480V - DISTRIBUTION NUMBER V PH A SIZE CM FEET VD V% Total V%

TO BALLAST PUMP MOTOR STARTER SB1-1 480 3 4.8 F-6 6530 48 0.79 0.16 0.30

TO BALLAST PUMP MOTOR SB1-1A 480 3 4.8 F-6 6530 40 0.66 0.14 0.44

TO AIR COMPRESSOR MOTOR STARTER SB1-2 480 3 40 F-6 6530 12 1.64 0.34 0.48

TO AIR COMPRESSOR MOTOR SB1-2A 480 3 40 F-6 6530 50 6.84 1.43 1.90

TO SPUD WINCH NO.1 PORT VFD SB1-3 480 3 77 F-83 83700 36 0.74 0.15 0.29

TO SPUD WINCH NO.1 PORT MOTOR SB1-3A 480 3 77 F-83 83700 64 1.32 0.27 0.56

TO SPUD WINCH NO.2 STBD VFD SB1-4 480 3 77 F-83 83700 28 0.58 0.12 0.25

TO SPUD WINCH NO.2 STBD MOTOR SB1-4A 480 3 77 F-83 83700 64 1.32 0.27 0.53

TO SPUD WINCH NO.3 VFD SB1-5 480 3 77 F-83 83700 34 0.70 0.15 0.28

TO SPUD WINCH NO.3 MOTOR SB1-5A 480 3 77 F-83 83700 60 1.23 0.26 0.54

TO PANEL P1 SB1-6 480 3 201 F-168 168000 48 1.28 0.27 0.40

TO OFF VESSEL RECEPTACLE PORT SB1-7 480 3 131 F-106 105500 56 1.55 0.32 0.41

TO OFF VESSEL RECEPTACLE STBD SB1-8 480 3 131 F-83 83700 20 0.70 0.15 0.28

TO 480-208/120V TRANSFORMER NO.1 SBTP-1 480 3 232 F-212 212000 30 0.73 0.15 0.29

TO 480-208/120V TRANSFORMER NO.2 SBTP-2 480 3 232 F-212 212000 30 0.73 0.15 0.29

TO RACK & PINION NO.1 MOTOR STARTER SB2-1 480 3 11 F-6 6530 12 0.45 0.09 0.23

TO RACK & PINION NO.1 MOTOR SB2-1A 480 3 11 F-6 6530 40 1.51 0.31 0.54

TO GEN ROOM SUPPLY FAN MOTOR STARTER SB2-2 480 3 3.4 F-6 6530 52 0.60 0.13 0.26

TO GEN ROOM SUPPLY FAN MOTOR SB2-2A 480 3 3.4 F-6 6530 12 0.14 0.03 0.29

TO GEN ROOM EXHAUST FAN MOTOR STARTER SB2-3 480 3 4.8 F-6 6530 52 0.85 0.18 0.31

TO GEN ROOM EXHAUST FAN MOTOR SB2-3A 480 3 4.8 F-6 6530 12 0.20 0.04 0.35

TO RACK & PINION NO.2 STARTER SB2-4 480 3 11 F-6 6530 12 0.45 0.09 0.23

TO RACK & PINION NO.2 MOTOR SB2-4A 480 3 11 F-6 6530 52 1.96 0.41 0.64

TO OFF VESSEL RECEPTACLE AFT SB2-5 480 3 48 F-83 83700 100 1.28 0.27 0.40

TO PANEL P2 SB2-6 480 3 111 F-168 168000 44 0.65 0.14 0.27

SWITCHBOARD 208/120V DISTRIBUTION CIRCUIT

208/120V - DISTRIBUTION NUMBER V PH A SIZE CM FEET VD V% Total V%

FROM 480-208/120V TRANSFORMER NO.1 TS-1 208 3 259 F-250 250000 25 0.58 0.28 0.36

FROM 480-208/120V TRANSFORMER NO.2 TS-2 208 3 259 F-250 250000 25 0.58 0.28 0.36

TO 208/120V DISTRIBUTION PANEL SBTS-1 208 3 259 F-250 250000 25 0.58 0.28 0.64

TO PANEL L1 SB-L1 208 3 150 F-106 106500 28 0.88 0.42 0.79

TO PANEL L2 SB-L2 208 3 150 F-250 250000 90 1.21 0.58 0.94

TO PANEL L3 SB-L3 208 3 150 F-106 106500 50 1.57 0.76 1.12

TO PANEL L4 SB-L4 208 3 150 F-106 106500 62 1.95 0.94 1.30

TO PRIMARY CONDENSOR UNIT SB-L5B 208 1 20 F-16 16510 40 1.25 0.60 0.96

TO MARINE SANITATION DEVICE SB-L6 208 3 10 F-6 6530 45 1.54 0.74 1.10

TO MARINE SANITATION DEVICE MOTOR STARTER SB-L6A 208 3 10 F-6 6530 60 2.05 0.99 1.35

TO SWBD ROOM AIR HANDLING UNIT NO.1 SB-L7A 208 1 29 T-6 6530 30 3.44 1.65 2.01

TO SWBD ROOM AIR HANDLING UNIT NO.2 SB-L7B 208 1 29 T-6 6530 30 3.44 1.65 2.01

TO GENERATOR ROOM AIR HANDLING UNIT NO.1 SB-L7C 208 1 29 T-6 6530 30 3.44 1.65 2.01

TO OIL BOILER MOTOR SB-L8A 208 1 29 T-10 10380 60 4.32 2.08 2.44

TO GENERATOR ROOM AIR HANDLING UNIT NO.2 SB-L8B 208 1 29 T-6 6530 30 3.44 1.65 2.01

TO GENERATOR ROOM AIR HANDLING UNIT NO.3 SB-L8C 208 1 29 T-6 6530 30 3.44 1.65 2.01

TO PANEL L5 SB-L9 208 1 150 F-106 106500 40 1.45 0.70 1.06

PANEL P1 CIRCUIT

480V - EQUIPMENT POWER PANEL NUMBER V PH A SIZE CM FEET VD V% Total V%

TO DECK WINCH NO.1 MOTOR STARTER P1-1 480 3 11.0 F-6 6530 12 0.45 0.09 0.50

TO DECK WINCH NO.1 MOTOR P1-1A 480 3 11.0 F-6 6530 86 3.24 0.67 1.17

TO DECK WINCH NO.2 MOTOR STARTER P1-2 480 3 11.0 F-6 6530 12 0.45 0.09 0.50

TO DECK WINCH NO.2 MOTOR P1-2A 480 3 11.0 F-6 6530 120 4.52 0.94 1.44

TO LUBE OIL TRANSFER PUMP MOTOR STARTER P1-3 480 3 4.8 F-6 6530 12 0.20 0.04 0.44

TO LUBE OIL TRANSFER PUMP MOTOR P1-3A 480 3 4.8 F-6 6530 34 0.56 0.12 0.56

TO WASTE OIL TRANSFER PUMP MOTOR STARTER P1-4 480 3 3.4 F-6 6530 12 0.14 0.03 0.43

TO WASTE OIL TRANSFER PUMP MOTOR P1-4A 480 3 3.4 F-6 6530 34 0.40 0.08 0.51

TO WASTE OIL COLLECTION PUMP MOTOR STARTER P1-5 480 3 3.4 F-6 6530 12 0.14 0.03 0.43

TO WASTE OIL COLLECTION PUMP MOTOR P1-5A 480 3 3.4 F-6 6530 34 0.40 0.08 0.51

TO FUEL OIL TRANSFER PUMP MOTOR STARTER P1-6 480 3 4.8 F-6 6530 12 0.20 0.04 0.44

TO FUEL OIL TRANSFER PUMP MOTOR P1-6A 480 3 4.8 F-6 6530 36 0.59 0.12 0.57

TO SWBD ROOM EXHAUST FAN MOTOR STARTER P1-7 480 3 2.1 F-6 6530 12 0.09 0.02 0.42

TO SWBD ROOM EXHAUST FAN MOTOR P1-7A 480 3 2.1 F-6 6530 20 0.14 0.03 0.45

TO TANK ROOM EXHAUST FAN MOTOR STARTER P1-8 480 3 2.1 F-6 6530 12 0.09 0.02 0.42

TO TANK ROOM EXHAUST FAN MOTOR P1-8A 480 3 2.1 F-6 6530 30 0.22 0.04 0.47

DECK WASHDOWN PUMP MOTOR STARTER P1-9 480 3 2.1 F-6 6530 12 0.09 0.02 0.48

DECK WASHDOWN PUMP MOTOR P1-9A 480 3 2.1 F-6 6530 30 0.22 0.04 0.53

STBD COMP. EXHAUST FAN MOTOR STARTER P1-10 480 3 2.1 F-6 6530 12 0.09 0.02 0.55

STBD COMP. EXHAUST FAN MOTOR P1-10A 480 3 2.1 F-6 6530 20 0.14 0.03 0.58

PORT COMP. EXHAUST FAN MOTOR STARTER P1-11 480 3 2.1 F-6 6530 12 0.09 0.02 0.59

PORT COMP. EXHAUST FAN MOTOR P1-11A 480 3 2.1 F-6 6530 20 0.14 0.03 0.62

PANEL P2 CIRCUIT

480V - EQUIPMENT POWER PANEL NUMBER V PH A SIZE CM FEET VD V% Total V%

TO HYDRAULIC OIL TRANSFER PUMP MOTOR STARTER P2-1 480 3 4.8 F-6 6530 12 0.20 0.04 0.31

TO HYDRAULIC OIL TRANSFER PUMP MOTOR P2-1A 480 3 4.8 F-6 6530 52 0.85 0.18 0.49

TO STORE 4P-A EXHAUST FAN MOTOR STARTER P2-2 480 3 2.1 F-6 6530 12 0.09 0.02 0.29

TO STORE 4P-A EXHAUST FAN MOTOR P2-2A 480 3 2.1 F-6 6530 58 0.42 0.09 0.38

TO POTABLE WATER TRANSFER PUMP MOTOR STARTER P2-3 480 3 4.8 F-6 6530 12 0.20 0.04 0.31

TO POTABLE WATER TRANSFER PUMP MOTOR P2-3A 480 3 4.8 F-6 6530 54 0.89 0.18 0.50

TO STORE 4S-A EXHAUST FAN MOTOR STARTER P2-4 480 3 2.1 F-6 6530 12 0.09 0.02 0.29

TO STORE 4S-A EXHAUST FAN MOTOR P2-4A 480 3 2.1 F-6 6530 42 0.30 0.06 0.35

TO PUMP ROOM EXHAUST FAN MOTOR STARTER P2-5 480 3 2.1 F-6 6530 12 0.09 0.02 0.29

TO PUMP ROOM EXHAUST FAN MOTOR P2-5A 480 3 2.1 F-6 6530 42 0.30 0.06 0.35

TO STORE 4C EXHAUST FAN MOTOR STARTER P2-6 480 3 2.1 F-6 6530 12 0.09 0.02 0.29

TO STORE 4C EXHAUST FAN MOTOR P2-6A 480 3 2.1 F-6 6530 46 0.33 0.07 0.36

TO DECK WINCH NO.3 MOTOR STARTER P2-7 480 3 11.0 F-6 6530 12 0.45 0.09 0.36

TO DECK WINCH NO.3 MOTOR P2-7A 480 3 11.0 F-6 6530 86 3.24 0.67 1.04

TO DECK WINCH NO.4 MOTOR STARTER P2-8 480 3 11.0 F-6 6530 12 0.45 0.09 0.36

TO DECK WINCH NO.4 MOTOR P2-8A 480 3 11.0 F-6 6530 120 4.52 0.94 1.31

TO PORT WINCH EXHAUST FAN MOTOR STARTER P2-9 480 3 2.1 F-6 6530 12 0.09 0.02 0.29

TO PORT WINCH EXHAUST FAN MOTOR P2-9A 480 3 2.1 F-6 6530 20 0.14 0.03 0.32

TO STBD WINCH EXHAUST FAN MOTOR STARTER P2-10 480 3 2.1 F-6 6530 12 0.09 0.02 0.29

TO STBD WINCH EXHAUST FAN MOTOR P2-10A 480 3 2.1 F-6 6530 40 0.29 0.06 0.35

TO STORE ROOM 5-C EXHAUST FAN MOTOR STARTER P2-11 480 3 2.1 F-6 6530 12 0.09 0.02 0.29

TO STORE ROOM 5-C EXHAUST FAN MOTOR P2-11A 480 3 2.1 F-6 6530 40 0.29 0.06 0.35

TO STORE ROOM 5P-A EXHAUST FAN MOTOR STARTER P2-12 480 3 2.1 F-6 6530 12 0.09 0.02 0.29

TO STORE ROOM 5P-A EXHAUST FAN MOTOR P2-12A 480 3 2.1 F-6 6530 50 0.36 0.07 0.36

TO STORE ROOM 5S-A EXHAUST FAN MOTOR STARTER P2-13 480 3 2.1 F-6 6530 12 0.09 0.02 0.29

TO STORE ROOM 5S-A EXHAUST FAN MOTOR P2-13A 480 3 2.1 F-6 6530 30 0.22 0.04 0.33

PANEL L1 CIRCUIT

208/120 V - EQUIPMENT PANEL NUMBER V PH A SIZE CM FEET VD V% Total V%

24 VDC SYS CHARGER L1-1 120 1 12.5 T-6 6530 50 2.47 2.06 2.84

GENERATOR 1 CHARGER L1-2 120 1 12.5 T-6 6530 50 2.47 2.06 2.84

AIR HANDLING UNIT WITH BOILER HEAT (VOID 2S-A) L1-3 120 1 12.5 T-6 6530 50 2.47 2.06 2.84

GENERATOR 2 CHARGER L1-4 120 1 12.5 T-6 6530 50 2.47 2.06 2.84

24 VDC E-LIGHT CHARGER L1-5 120 1 12.5 T-6 6530 50 2.47 2.06 2.84

GENERATOR 3 CHARGER L1-6 120 1 12.5 T-6 6530 50 2.47 2.06 2.84

GENERATOR BLOCK HEATER 1 L1-7 120 1 12.5 T-6 6530 50 2.47 2.06 2.84

GENERATOR ROOM LIGHTING 1 L1-8 120 1 6.0 T-6 6530 50 1.19 0.99 1.77

GENERATOR BLOCK HEATER 2 L1-9 120 1 12.5 T-6 6530 50 2.47 2.06 2.84

GENERATOR ROOM LIGHTING 2 L1-10 120 1 6.0 T-6 6530 50 1.19 0.99 1.77

GENERATOR BLOCK HEATER 3 L1-11 120 1 12.5 T-6 6530 50 2.47 2.06 2.84

GENERATOR ROOM RECEPTACLES L1-12 120 1 8.0 T-6 6530 90 2.84 2.37 3.16

SWITCHBOARD SPACE HEATERS L1-13 120 1 12.5 T-6 6530 50 2.47 2.06 2.84

GENERATOR ROOM RECEPTACLES L1-14 120 1 10.0 T-6 6530 90 3.56 2.96 3.75

CONTROL ROOM LIGHTING L1-15 120 1 7.5 T-6 6530 50 1.48 1.23 2.02

VOID 2S-A LIGHTING AND RECEPTACLES L1-16 120 1 6.0 T-6 6530 90 2.13 1.78 2.56

CONTROL ROOM RECEPTACLES L1-17 120 1 8.0 T-6 6530 90 2.84 2.37 3.16

DECK STORAGE ROOM LIGHTS L1-18 120 1 4.2 T-6 6530 50 0.83 0.69 1.48

CONTROL ROOM RECEPTACLES L1-19 120 1 8.0 T-6 6530 90 2.84 2.37 3.16

FWD STBD FLOOD-LIGHT L1-20 120 1 5.2 T-6 6530 50 1.03 0.86 1.64

STBD ENTRANCE ROOM LIGHTING L1-21 120 1 6.7 T-6 6530 50 1.32 1.10 1.89

AFT STBD FLOOD-LIGHT L1-22 120 1 5.2 T-6 6530 50 1.03 0.86 1.64

STBD ENTRANCE ROOM RECEPTACLES L1-23 120 1 14.0 T-6 6530 90 4.98 4.15 4.93

PORT ENTRANCE ROOM RECEPTACLES L1-24 120 1 8.0 T-6 6530 90 2.84 2.37 3.16

EXT HOUSE RECEPTACLES (STBD) L1-25 120 1 8.0 T-6 6530 90 2.84 2.37 3.16

EXTERIOR LIGHTS (STBD) L1-26 120 1 16.0 T-6 6530 50 3.16 2.63 3.42

EXT HOUSE RECEPTACLES (STBD) L1-27 120 1 8.0 T-6 6530 90 2.84 2.37 3.16

GENERAL ALARM BATTERY CHARGER L1-28 120 1 12.5 T-6 6530 50 2.47 2.06 2.84

208V DECK RECEPTACLE (STBD) AT SPUD WINCH L1-29,31 208 1 18.0 T-6 6530 90 6.40 3.08 3.86

208V DECK RECEPTACLES (STBD) L1-30,32 208 1 6.0 T-6 6530 90 2.13 1.03 1.81

VENT LOCKER LIGHTING & RECEPTACLES L1-33 120 1 4.2 T-6 6530 90 1.49 1.24 2.03

DECK LOCKER & CO2 ROOM LIGHTING L1-34 120 1 5.2 T-6 6530 90 1.85 1.54 2.33

E-LIGHT SENSOR R4 L1-35 120 1 6.0 T-6 6530 50 1.19 0.99 1.77

PANEL L2 CIRCUIT

SEWAGE TRANSFER PUMP NO.1 MOTOR STARTER L2-1,3,5 208 3 10.6 F-6 6530 12 0.44 0.21 1.15

SEWAGE TRANSFER PUMP NO.1 MOTOR L2-1,3,5 208 3 10.6 F-6 6530 54 1.96 0.94 1.88

SEWAGE TRANSFER PUMP NO.2 MOTOR STARTER L2-2,4,6 208 3 10.6 F-6 6530 12 0.50 0.24 1.18

SEWAGE TRANSFER PUMP NO.2 MOTOR L2-2,4,6 208 3 10.6 F-6 6530 54 2.26 1.09 2.03

SEWAGE LIFTING PUMP MOTOR STARTER L2-7 120 1 3.5 T-10 10380 12 0.10 0.09 1.21

SEWAGE LIFTING PUMP MOTOR L2-7A 120 1 3.5 T-10 10380 54 0.47 0.39 1.69

WATER HEATER MOTOR STARTER L2-8 120 1 35.0 T-10 10380 12 1.04 0.87 1.81

WATER HEATER MOTOR L2-8A 120 1 35.0 T-10 10380 54 4.70 3.91 4.86

WINCH ROOM 4P-B LIGHTS AND RECEPTACLES L2-9 120 1 12.5 T-6 6530 90 4.44 3.70 4.65

STORE ROOM 4P-A LIGHTS AND RECEPTACLES L2-10 120 1 12.5 T-6 6530 90 4.44 3.70 4.65

WINCH ROOM 4S-B LIGHTS AND RECEPTACLES L2-11 120 1 12.5 T-6 6530 90 4.44 3.70 4.65

STORAGE ROOM 4C LIGHTS AND RECEPTACLES L2-12 120 1 10.5 T-6 6530 90 3.73 3.11 4.05

STOREAGE ROOM 5P-A, 5C, 5S-A LIGHTS L2-13 120 1 9.7 T-6 6530 90 3.45 2.87 3.82

STORAGE ROOM 4S-A LIGHTS & RECEPTACLES L2-14 120 1 9.7 T-6 6530 90 3.45 2.87 3.82

AIR HANDLING UNIT W/ BOILER HEAT (VOID 5P-B) L2-15 120 1 6.5 T-6 6530 90 2.31 1.93 2.87

STORAGE ROOM 5P-A, 5C, 5S-A RECEPTACLES L2-16 120 1 16.0 T-6 6530 70 4.43 3.69 4.63

AIR HANDLING UNIT W/ BOILER HEAT (5P-A) L2-17 120 1 6.5 T-6 6530 60 1.54 1.28 2.23

AIR HANDLING UNIT W/ BOILER HEAT (5S-B) L2-18 120 1 6.5 T-6 6530 70 1.80 1.50 2.44

AIR HANDLING UNIT W/ BOILER HEAT (5C) L2-19 120 1 6.5 T-6 6530 50 1.28 1.07 2.01

AIR HANDLING UNIT W/ BOILER HEAT NO.1 (4P-B) L2-20 120 1 6.5 T-6 6530 40 1.03 0.86 1.80

AIR HANDLING UNIT W/ BOILER HEAT (5S-A) L2-21 120 1 6.5 T-6 6530 40 1.03 0.86 1.80

AIR HANDLING UNIT W/ BOILER HEAT NO.2 (4P-B) L2-22 120 1 6.5 T-6 6530 40 1.03 0.86 1.80

AIR HANDLING UNIT W/ BOILER HEAT NO.1 (4P-A) L2-23 120 1 6.5 T-6 6530 40 1.03 0.86 1.80

AIR HANDLING UNIT W/ BOILER HEAT NO.1 (4S-B) L2-24 120 1 6.5 T-6 6530 40 1.03 0.86 1.80

AIR HANDLING UNIT W/ BOILER HEAT NO.2 (4P-A) L2-25 120 1 6.5 T-6 6530 40 1.03 0.86 1.80

AIR HANDLING UNIT W/ BOILER HEAT NO.2 (4S-B) L2-26 120 1 6.5 T-6 6530 40 1.03 0.86 1.80

AIR HANDLING UNIT W/ BOILER HEAT NO.1 (4C) L2-27 120 1 6.5 T-6 6530 40 1.03 0.86 1.80

AIR HANDLING UNIT W/ BOILER HEAT NO.1 (4S-A) L2-28 120 1 6.5 T-6 6530 40 1.03 0.86 1.80

AIR HANDLING UNIT W/ BOILER HEAT NO.2 (4C) L2-29 120 1 6.5 T-6 6530 40 1.03 0.86 1.80

AIR HANDLING UNIT W/ BOILER HEAT NO.2 (4S-A) L2-30 120 1 6.5 T-6 6530 40 1.03 0.86 1.80

E-LIGHT SENSOR LR1 L2-31 120 1 6.0 T-6 6530 62 1.47 1.22 2.17

PANEL L3 CIRCUIT

POTABLE WATER PRESSURE PUMP MOTOR STARTER L3-1,3,5 208 3 4.8 F-6 6530 12 0.20 0.094751 1.21

POTABLE WATER PRESSURE PUMP MOTOR L3-1A 208 3 4.8 F-6 6530 22 0.36 0.17371 1.29

FROM FIRE ALARM PANEL L3-2 120 1 11.0 T-6 6530 30 1.30 1.086524 2.20

CONDENSING UNIT (OFFICE, LOCKER, HEAD) L3-4,6 208 2 25.0 T-10 10500 30 1.84 0.885989 2.00

LOCKER ROOM LIGHTING AND RECEPTACLES L3-7 120 1 13.0 T-6 6530 70 3.60 2.996172 4.11

AIR HANDLING UNIT W/ BOILER HEAT COIL (OFFICE) L3-8 120 1 6.5 T-6 6530 40 1.03 0.856049 1.97

AIR HANDLING UNIT W/ BOILER HEAT COIL (HEAD) L3-9 120 1 6.5 T-6 6530 40 1.03 0.856049 1.97

AIR HANDLING UNIT W/ BOILER HEAT COIL (LOCKER) L3-10 120 1 6.5 T-6 6530 40 1.03 0.856049 1.97

PUMP ROOM LIGHTING L3-11 120 1 10.0 T-6 6530 42 1.66 1.382848 2.50

PORT HOUSE EXTERIOR LIGHTING L3-12 120 1 16.0 T-6 6530 60 3.79 3.160796 4.28

PUMP ROOM RECEPTACLES L3-13 120 1 10.0 T-6 6530 70 2.77 2.304747 3.42

PORT HOUSE EXT RECEPTACLES L3-14 120 1 10.0 T-6 6530 70 2.77 2.304747 3.42

TANK ROOM LIGHTING L3-15 120 1 8.0 T-6 6530 70 2.21 1.843798 2.96

PORT HOUSE EXT RECEPTACLES L3-16 120 1 10.0 T-6 6530 70 2.77 2.304747 3.42

TANK ROOM RECEPTACLES L3-17 120 1 12.0 T-6 6530 70 3.32 2.765697 3.88

PORT HOUSE ENTRANCE ROOM LIGHTS L3-18 120 1 6.7 T-6 6530 50 1.32 1.102986 2.27

AIR HANDLING UNIT W/ BOILER HEAT COIL (TANK ROOM) L3-19 120 1 6.5 T-6 6530 70 1.80 1.498086 2.62

FWD PORT FLOOD-LIGHT L3-20 120 1 5.2 T-6 6530 70 1.44 1.198469 2.32

AIR HANDLING UNIT W/ BOILER HEAT COIL (TANK ROOM) L3-21 120 1 6.5 T-6 6530 70 1.80 1.498086 2.62

AFT PORT FLOOD-LIGHT L3-22 120 1 5.2 T-6 6530 70 1.44 1.198469 2.32

AIR HANDLING UNIT W/ BOILER HEAT COIL (PUMP ROOM) L3-23 120 1 6.5 T-6 6530 90 2.31 1.92611 3.04

208V DECK RECEPTACLES L3-24,26 208 2 4.0 T-6 6530 90 1.42 0.683826 1.80

AIR HANDLING UNIT W/ BOILER HEAT COIL (PUMP ROOM) L3-25 120 1 6.5 T-6 6530 70 1.80 1.498086 2.62

FUEL OIL HOSE REEL L3-27 120 1 9.8 T-6 6530 50 1.94 1.613323 2.73

208V DECK RECEPTACLE (PORT) @SPUD L3-28,30 208 2 18.0 T-6 6530 90 6.40 3.077218 4.20

PANEL L4 CIRCUIT

RANGE L4-1,3,5 208 3 11 F-6 6530 52 1.96 0.94 2.24

CONDENSING UNIT (BREAK AND OPERATION ROOM) L4-2,4 208 2 25 T-6 6530 40 3.95 1.90 3.20

FROM FIRE ALARM PANEL L4-6 120 1 11 T-6 6530 40 1.74 1.45 2.75

OFFICE LIGHTING L4-7 120 1 6.2 T-6 6530 60 1.47 1.22 2.52

AIR HANDLING W/ BOILER HEAT COIL (BREAK) L4-8 120 1 6.5 T-6 6530 52 1.34 1.11 2.41

OFFICE RECEPTACLES #1 L4-9 120 1 8 T-6 6530 80 2.53 2.11 3.41

AIR HANDLING W/ BOILER HEAT COIL (BREAK) L4-10 120 1 6.5 T-6 6530 60 1.54 1.28 2.58

OFFICE RECEPTACLES #2 L4-11 120 1 8 T-6 6530 70 2.21 1.84 3.14

AIR HANDLING W/ BOILER HEAT COIL (OPERATION) L4-12 120 1 6.5 T-6 6530 40 1.03 0.86 2.16

COFFEE MAKER RECEPTACLES L4-13 120 1 16 T-6 6530 30 1.90 1.58 2.88

BREAK ROOM LIGHTING L4-14 120 1 5 T-6 6530 70 1.38 1.15 2.45

REFRIGERATOR L4-15 120 1 16 T-6 6530 50 3.16 2.63 3.93

MICROWAVE L4-17 120 1 11 T-6 6530 60 2.61 2.17 3.47

BREAK ROOM RECEPTACLES NO.1 L4-18 120 1 8 T-6 6530 70 2.21 1.84 3.14

HEAD LIGHTS AND RECEPTACLES L4-19 120 1 10 T-6 6530 80 3.16 2.63 3.93

BREAK ROOM RECEPTACLES NO.2 L4-20 120 1 8 T-6 6530 70 2.21 1.84 3.14

GALLEY VENT HOOD L4-21 120 1 6.5 T-6 6530 30 0.77 0.64 1.94

TV & WIFI SYSTEM RECEPTACLES L4-22 120 1 4 T-6 6530 50 0.79 0.66 1.96

OPERATOR ROOM 1 RECEPTACLES L4-23 120 1 4 T-6 6530 70 1.11 0.92 2.22

COUNTER TOP RECEPTACLES NO.2 L4-24 120 1 14 T-6 6530 70 3.87 3.23 4.53

OPERATOR ROOM RECEPTACLES NO.2 L4-25 120 1 4 T-6 6530 70 1.11 0.92 2.22

VOID LIGHTING AND RECEPTACLES (2P-A) L4-26 120 1 9 T-6 6530 70 2.49 2.07 3.37

UNDER SINK DRAIN PUMP MOTOR STARTER L4-27 120 1 7.2 T-7 6530 15 0.43 0.36 1.32

UNDER SINK DRAIN PUMP L4-27A 120 1 7.2 T-8 6530 50 1.42 1.19 2.29

E-LIGHT SENSOR LR3 L4-28 120 1 6 T-6 6530 90 2.13 1.78 3.08

PANEL L5 CIRCUIT

BILGE PUMP NO.1 L5-1 120 1 5.4 T-6 6530 85 1.81 1.511256 2.57

BILGE PUMP NO.2 L5-2 120 1 5.4 T-6 6530 85 1.81 1.511256 2.57

BILGE PUMP NO.3 L5-3 120 1 5.4 T-6 6530 85 1.81 1.511256 2.57

BILGE PUMP NO.4 L5-4 120 1 5.4 T-6 6530 85 1.81 1.511256 2.57

BILGE PUMP NO.5 L5-5 120 1 5.4 T-6 6530 85 1.81 1.511256 2.57

BILGE PUMP NO.6 L5-6 120 1 5.4 T-6 6530 85 1.81 1.511256 2.57

BILGE PUMP NO.7 L5-7 120 1 5.4 T-6 6530 85 1.81 1.511256 2.57

BILGE PUMP NO.8 L5-8 120 1 5.4 T-6 6530 85 1.81 1.511256 2.57

BILGE PUMP NO.9 L5-9 120 1 5.4 T-6 6530 85 1.81 1.511256 2.57

BILGE PUMP NO.10 L5-10 120 1 5.4 T-6 6530 85 1.81 1.511256 2.57

BILGE PUMP NO.11 L5-11 120 1 5.4 T-6 6530 85 1.81 1.511256 2.57

BILGE PUMP NO.12 L5-12 120 1 5.4 T-6 6530 85 1.81 1.511256 2.57

BILGE PUMP NO.13 L5-13 120 1 5.4 T-6 6530 85 1.81 1.511256 2.57

File details come from the government source that posted it. Updated .