August 8, 2016 T201606-2272Rev
Jeff Longshore Nelson Engineering Co.
5335 N. Courtney Parkway Merritt Island, FL 32953
ASBESTOS \ METALS \ PCBs BULK SAMPLE/ANALYSIS; [RFQ#: RFQNE2016-101]
J7-0337; LAUNCH COMPLEX 39B, SAMPLE AREAS 1, 2 AND 3
Revision: The Metals/PCB Analysis Summary has been updated. All PCB results should have been shown as milligrams (mg/Kg), not micrograms (ug/Kg) as submitted in the previous report. Please discard previous report and replace with corrected version.
REPORT SUMMARY:
Asbestos containing materials (ACM) are present in the pipe/flange gasket material identified in sample Area 2.
This material is subject to OSHA 29 CFR 1926.1101 Asbestos in Construction regulations and EPA’s Asbestos NESHAP (40 CFR 61) requirements as specified below.
Hazardous metals and PCBs are present above analytical detection limits in the paint coatings in sample areas 1, 2, and 3. Based on the materials present in the paint coatings, the identified surface coatings/paints are subject to federal, state and local occupational health protection and environmental requirements as specified below.
The IMSS Industrial Hygiene Office performed an inspection/evaluation for Asbestos, Hazardous (total) metals and polychlorinated biphenyls (PCBs) of suspect materials and surface coatings in the subject area per your request. The purpose of this inspection was to evaluate the potential hazards associated with the suspect building materials/coatings and provide health protection recommendations for work involving renovation activities.
The survey area consisted of three specific locations along the east perimeter of the LC39B pad compound and specific materials as requested in RFQNE2016-101.The suspect materials observed were categorized by type and homogeneous area. A homogeneous area contains material that is uniform in color, texture and appearance, was installed at approximately the same time, and is believed to consist of only one type or formulation of material. The survey was performed by visual inspection of suspect materials and obtaining representative samples from randomly selected areas.
Seven suspect homogenous asbestos containing materials and seventeen suspected hazardous metals paint coatings were identified and inspected by this office. The visual survey determines’ only general locations of suspect materials and may not determine exact boundaries. No attempt was made to disassemble equipment or to demolish structural elements.
Visual observations were made at accessible locations in the three specified sample areas identified in Attachment 1.
Asbestos The asbestos survey was performed in accordance with AHERA protocols and samples were analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratory using polarized-light microscopy (PLM)), EPA/600/R-93/116; Method for Determination of Asbestos in Bulk Building Materials. The asbestos inspection consisted of identifying suspect asbestos containing materials associated with the three specified survey areas. A total of seven suspect ACBMs were identified in Sample Area 2. Inspection/survey results indicated asbestos is present in one of the homogenous materials identified in this area as summarized in Attachment 2. The identified pipe flange gasket (MG06) is a friable material that must be handled/disposed of during renovation/demolition activities in accordance with OSHA’s Asbestos Construction Standard (29 CFR 1926.1101), EPA’s Asbestos NESHAP (40 CFR 61), Florida Statute (Chapter
469) and NASA KNPRs (1840.19, 8715.7 & 8500.1) requirements. Personnel assigned work in these areas must be provided hazard notification of the presence and locations of the identified asbestos containing material. Appropriate work practices (wet methods, HEPA vacuums), personal protective equipment (PPE) and worker training must be used during disturbance or removal of the identified ACM to ensure adequate fiber control and employee health protection during the planned renovation activities.
T201606-2272
Hazardous Metals/PCBs Bulk samples representative of the specified homogenous suspect paint coatings were obtained and submitted to accredited laboratories for analyses. A minimum of three or more samples (per KNPR 1840.19) representative of the homogenous coatings were obtained of sufficient volume (10-15 grams) to provide analytical detection limits. The paint coatings were analyzed by an American Industrial Hygiene Association (AIHA) accredited laboratory for analysis of total metals and PCBs. Seventeen different homogenous paint coatings were observed (Attachment 3) to be present throughout the three areas inspected. The paint coatings were similar in appearance, color and use, and were considered homogenous for this evaluation. Sampling was performed to remove all paint layers down to the bare metal substrate for analysis. The samples were collected from various random locations within the homogeneous areas identified to ensure similarity based on color and use. Total metal analysis for Barium (Ba), Cadmium (Cd), Chromium (Cr), Lead (Pb), Mercury (Hg), Hexavalent Chromium (Cr6) and PCBs were performed on the suspect paint coatings. As verbally reported to you, the laboratory analysis results indicated that hazardous (total) metals (Ba, Cd, Cr & Cr6, Pb, Hg) and PCBs (Aroclor 1254, 1248 & 1260) are present above analytical detection limits in the suspect coatings.
Based on the hazardous (total) metals detected to be present, the disturbance of the metal and concrete surface coatings within sample areas 1, 2 and 3 are subject to federal, state and local health protection requirements. The concentration of total metals (Ba, Cd, Cr, Cr6, Pb, & Hg) present in the paint coatings may be sufficient to generate airborne respirable aerosols above the permissible exposure limit during renovation activities. Disturbance of the identified paint coatings is subject to OSHA’s substance specific standards for; Lead (29CFR1926.62), Hexavalent Chromium (29CFR 1926.1126), Cadmium (29CFR 1926.1027), PCBs and other metals (29CFR 1910.1000) to ensure personnel health protection.
The potential for personnel exposure to hazardous metals and PCBs found in the paint depends on the location work is performed, methods of removal/disturbance and protective control measures used. Personal protective equipment and work practices must be used to minimize dust generation and ensure adequate protection of the workers as well as adjacent, unprotected personnel when disturbing the identified paint coatings. Worker training, work practices, air and medical monitoring is required when removing/handling the subject coatings. PCB health protection will depend on the method of removal used and level of disturbance.
Personnel disturbing these paint coatings must utilize PPE based upon anticipated level of disturbance, which may include respiratory protection, protective clothing, gloves and use of good hygiene practices to prevent/minimize direct skin contact, such as washing hands prior to breaks/lunch, etc. and at end of the day. Please refer to the applicable OSHA and KNPR standards for additional requirements.
It should be note that these analysis results were for determination of employee health protection requirements during the planned renovation project only. Disposal of waste generated from this project must be in accordance with environmental regulations and KNPR 8500.1. If you need additional information or have any questions concerning this inspection please contact this office at 867-2400.
J. R. Taffer, MSPH, CIH State of Florida Licensed Asbestos Consultant, AX0000016 State of Florida Licensed Asbestos Business Organization, ZA503 Industrial Hygiene, IMSS-022
ERF: EDS: MRC: dlg
Attachments:
1. Survey Area Location Map
2. Asbestos Materials Summary
3. Hazardous Metals/PCB Materials Summary cc: Michael Cardinale, SI-E1 Matt Doctor, SI-E1
Attachment 1 Survey Area Location
Survey Area 1
Survey Area 3
Survey Area 2
Attachment 2 Asbestos Analysis Summary
SURVEY AREA 1
Facility: J7-0337 Facility Description: LAUNCH PAD 39B Date of Inspection: 6/20/2016 Inspectors: DS, ERF
Comments: Nelson Engineering project specific survey (RFQNE2016-101) Sample Area 3; East pad perimeter road in general vicinity of Camera Pad B-1
SURVEY AREA 2
Facility: J7-0337 Facility Description: LAUNCH PAD 39B Date of Inspection: 6/20/2016 Inspectors: DS, ERF
Comments: Nelson Engineering project specific survey (RFQNE2016-101) Sample Area 2; South East pad perimeter road in general vicinity of the Foam Building
Asbestos Summary ID Material Type & Description Asbestos Friable Condition Qty Unit Photo
EW02
Electrical Materials (Wire) - GRAY MULTI
COLORED ELECTRICAL WIRING;
Survey Areas 2 & 3
Sample #s:
J14581 J14582 J14583
No Asbestos Detected
No Damaged 10 LF
MC01
Miscellaneous Material (Caulk) - BLACK
EXPANSION JOINT
Survey Area 2
Sample #s:
J14556 J14557 J14558
No Asbestos
No Damaged 30 LF
MG06
Miscellaneous Material (Gasket) -
GRAY GASKET
Survey Area 2
Sample #s:
J14562 J14563 J14564
Yes, 75%
Chrysotile Yes Severely
Damaged 2 Ea
MM03
Miscellaneous Material (Mastic) -
BLACK/OFF WHITE WALL MASTIC
Survey Area 2
Sample #s:
J14559 J14560 J14561
No Asbestos
No Damaged 50 LF http://amis.ksc.nasa.gov/facfound.asp?FacilityCode=J7-0337 http://amis.ksc.nasa.gov/matstat.asp?HomogMatID=EW02&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/matstat.asp?HomogMatID=MC01&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/matstat.asp?HomogMatID=MG06&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/matstat.asp?HomogMatID=MM03&facility=J7-0337&desc=LAUNCH%20PAD%2039B
MO12
Miscellaneous Material (Other) - GREY
CONCRETE WALL
Survey Area 2
Sample #s:
J14584 J4585 J4586
No Asbestos
No Good 0 N/A
PW02
Pipe Insulation, Straight (Wrap) - WATER
SERVICE INSULATION/BLACK STICKY
PIPE WRAP; Above grade pipe stub Survey Area 2
Sample #s:
J14553 J14554 J14555
No Asbestos
No Damaged 3 LF
SURVEY AREA 3
Comments: Nelson Engineering project specific survey (RFQNE2016-101) Sample Area 3; East pad perimeter road in general vicinity of Camera Pad B-1
Asbestos Summary ID Material Type & Description Asbestos Friable Condition Qty Unit Photo
EW02
Electrical Materials (Wire) - GRAY
MULTI COLORED ELECTRICAL
WIRING
Survey Area 2& 3
Sample #s:
J14581 J14582 J14583
No Asbestos
No Good 100 LF
EW03
Electrical Materials (Wire) - BLACK
RESINOUS MATERIAL
Survey Area 3
Sample #s:
J14592 J14593 J14594
No Asbestos
No Good 100 LF http://amis.ksc.nasa.gov/matstat.asp?HomogMatID=MO12&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/matstat.asp?HomogMatID=PW02&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/matstat.asp?HomogMatID=EW02&facility=J7-0337&desc= http://amis.ksc.nasa.gov/matstat.asp?HomogMatID=EW03&facility=J7-0337&desc= http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/pw02.jpg&FacCode=J7-0337&FacDesc=&MatID=PW02&MatDesc=WATER%20SERVICE%20INSULATION/BLACK%20STICKY%20PIPE%20WRAP&MatType=Pipe%20Insulation,%20Straight%20(Wrap) http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/ew02.jpg&FacCode=J7-0337&FacDesc=&MatID=EW02&MatDesc=GRAY%20MULTI%20COLORED%20ELECTRICAL%20WIRING&MatType=Electrical%20Materials%20(Wire) http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/ew03.jpg&FacCode=J7-0337&FacDesc=&MatID=EW03&MatDesc=BLACK%20RESINOUS%20MATERIAL&MatType=Electrical%20Materials%20(Wire)
Attachment 3 Metals/PCB Analysis Summary
: SURVEY AREA 1
Facility: J7-0337
Facility Description: LAUNCH PAD 39B Date of Inspection: 6/16/2016 Inspectors: DS, ERF
Comments: Nelson Engineering project specific survey (RFQNE2016-101) Sample Area 3; East pad perimeter road in general vicinity of Camera Pad B-1
Homogenous Materials HMID Type and Description Sample Id Commodity Findings Result Units
HMP11 - Hazardous Metals (Paint) -
YELLOW COATING ON BOLLARDS
AND POSTS
J14530 Barium Detectable Levels Present 620 mg/Kg Chromium Detectable Levels Present 5300 mg/Kg Chromium, Hexavalent Detectable Levels Present 3200 mg/Kg Lead Detectable Levels Present 21000 mg/Kg Cadmium Below Detection Limits < 45 mg/Kg Mercury Below Detection Limits < 60 ug/Kg
J14531 Barium Detectable Levels Present 680 mg/Kg Chromium Detectable Levels Present 7100 mg/Kg Chromium, Hexavalent Detectable Levels Present 4100 mg/Kg
Lead Detectable Levels Present 28000 mg/Kg
Cadmium Below Detection Limits < 47 mg/Kg
J14541 Barium Detectable Levels Present 4700 mg/Kg Chromium Detectable Levels Present 4600 mg/Kg Chromium, Hexavalent Detectable Levels Present 3200 mg/Kg Lead Detectable Levels Present 18000 mg/Kg Cadmium Below Detection Limits < 43 mg/Kg
J14546 Aroclor 1254 Detectable Levels Present .11 mg/Kg Aroclor 1016 Below Detection Limits < 0.093 mg/Kg Aroclor 1221 Below Detection Limits < 0.093 mg/Kg Aroclor 1232 Below Detection Limits < 0.093 mg/Kg Aroclor 1242 Below Detection Limits < 0.093 mg/Kg Aroclor 1248 Below Detection Limits < 0.093 mg/kg Aroclor 1260 Below Detection Limits < 0.093 mg/kg
HMP12 - Hazardous Metals (Paint) -
RED/WHITE COATING ON
CONCRETE WALL
J14526 Barium Detectable Levels Present 9100 mg/Kg Chromium Detectable Levels Present 990 mg/Kg Chromium, Hexavalent Detectable Levels Present 270 mg/Kg Lead Detectable Levels Present 4800 mg/Kg Cadmium Below Detection Limits < 49 mg/Kg
J14527 Barium Detectable Levels Present 11000 mg/Kg Chromium Detectable Levels Present 1200 mg/Kg Chromium, Hexavalent Detectable Levels Present 610 mg/Kg
Lead Detectable Levels Present 5700 mg/Kg
Cadmium Below Detection Limits < 45 mg/Kg
J14528 Barium Detectable Levels Present 9000 mg/Kg Chromium Detectable Levels Present 870 mg/Kg Chromium, Hexavalent Detectable Levels Present 430 mg/Kg Lead Detectable Levels Present 4200 mg/Kg Cadmium Below Detection Limits < 52 mg/Kg Mercury Below Detection Limits < 60 ug/Kg http://amis.ksc.nasa.gov/facfound.asp?FacilityCode=J7-0337 http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP11&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP12&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp11.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP11&MatDesc=YELLOW%20COATING%20ON%20BOLLARDS%20AND%20POSTS&MatType=Hazardous%20Metals%20(Paint) http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp12.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP12&MatDesc=RED/WHITE%20COATING%20ON%20CONCRETE%20WALL&MatType=Hazardous%20Metals%20(Paint)
J14529 Aroclor 1254 Detectable Levels Present .7 mg/Kg Aroclor 1016 Below Detection Limits < 97 mg/Kg Aroclor 1221 Below Detection Limits < 97 mg/Kg Aroclor 1232 Below Detection Limits < 97 mg/Kg Aroclor 1242 Below Detection Limits < 97 mg/Kg Aroclor 1248 Below Detection Limits < 97 mg/Kg Aroclor 1260 Below Detection Limits < 97 mg/kg
HMP13 - Hazardous Metals (Paint) -
GRAY COATING ON PIPE
SUPPORTS
J14521 Barium Detectable Levels Present 4200 mg/Kg Chromium Detectable Levels Present 740 mg/Kg Chromium, Hexavalent Detectable Levels Present 7.9 mg/Kg Lead Detectable Levels Present 8300 mg/Kg Cadmium Below Detection Limits < 42 mg/Kg
J14540 Barium Detectable Levels Present 14000 mg/Kg Cadmium Detectable Levels Present 52 mg/Kg Chromium Detectable Levels Present 550 mg/Kg
Chromium, Hexavalent Detectable Levels Present 2 mg/Kg
Lead Detectable Levels Present 5600 mg/Kg
J14545 Aroclor 1016 Below Detection Limits < .031 mg/Kg Aroclor 1221 Below Detection Limits < .042 mg/Kg Aroclor 1232 Below Detection Limits < .015 mg/Kg Aroclor 1242 Below Detection Limits < .014 mg/Kg Aroclor 1248 Below Detection Limits < .023 mg/Kg Aroclor 1254 Below Detection Limits < .028 mg/Kg Aroclor 1260 Below Detection Limits < .027 mg/Kg
J14549 Barium Detectable Levels Present 540 mg/Kg Chromium Detectable Levels Present 390 mg/Kg Chromium, Hexavalent Detectable Levels Present 46 mg/Kg Lead Detectable Levels Present 5400 mg/Kg Cadmium Below Detection Limits < 48 mg/Kg
HMP14 - Hazardous Metals (Paint) -
WHITE COATING ON HYDROGEN
TANKS
J14532 Barium Detectable Levels Present 19000 mg/Kg Chromium, Hexavalent Detectable Levels Present .040 mg/Kg Cadmium Below Detection Limits < 53 mg/Kg Chromium Below Detection Limits < 110 mg/Kg Lead Below Detection Limits < 110 mg/Kg
J14533 Barium Detectable Levels Present 13000 mg/Kg Cadmium Below Detection Limits < 53 mg/Kg Chromium Below Detection Limits < 110 mg/Kg
Chromium, Hexavalent Below Detection Limits < .035 mg/Kg
J14543 Barium Detectable Levels Present 6200 mg/Kg Chromium, Hexavalent Detectable Levels Present .078 mg/Kg Lead Detectable Levels Present 1100 mg/Kg Cadmium Below Detection Limits < 42 mg/Kg Chromium Below Detection Limits < 85 mg/Kg
J14548 Aroclor 1254 Detectable Levels Present .47 mg/Kg Aroclor 1016 Below Detection Limits < .032 mg/Kg Aroclor 1221 Below Detection Limits < .044 mg/kg http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP13&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP14&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp13.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP13&MatDesc=GRAY%20COATING%20ON%20PIPE%20SUPPORTS&MatType=Hazardous%20Metals%20(Paint) http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp14.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP14&MatDesc=WHITE%20COATING%20ON%20HYDROGEN%20TANKS&MatType=Hazardous%20Metals%20(Paint)
Aroclor 1232 Below Detection Limits < .015 mg/kg Aroclor 1242 Below Detection Limits < .015 mg/kg Aroclor 1248 Below Detection Limits < .024 mg/kg Aroclor 1260 Below Detection Limits < .028 mg/kg
HMP15 - Hazardous Metals (Paint) -
GRAY COATING ON LIGHT POLES
J14522 Barium Detectable Levels Present 10000 mg/Kg Cadmium Detectable Levels Present 110 mg/Kg Chromium Detectable Levels Present 2000 mg/Kg Chromium, Hexavalent Detectable Levels Present 120 mg/Kg Lead Detectable Levels Present 24000 mg/Kg
J14523 Barium Detectable Levels Present 11000 mg/Kg Cadmium Detectable Levels Present 58 mg/Kg Chromium Detectable Levels Present 1300 mg/Kg
Chromium, Hexavalent Detectable Levels Present 160 mg/Kg
Lead Detectable Levels Present 17000 mg/Kg
J14544 Barium Detectable Levels Present 33000 mg/Kg Chromium Detectable Levels Present 760 mg/Kg Chromium, Hexavalent Detectable Levels Present 37 mg/Kg Lead Detectable Levels Present 9600 mg/Kg Cadmium Below Detection Limits < 38 mg/Kg
J14552 Aroclor 1254 Detectable Levels Present .035 mg/Kg Aroclor 1016 Below Detection Limits < .03 mg/kg Aroclor 1221 Below Detection Limits < .041 mg/kg Aroclor 1232 Below Detection Limits < .014 mg/kg Aroclor 1242 Below Detection Limits < .014 mg/kg Aroclor 1248 Below Detection Limits < .023 mg/kg Aroclor 1260 Below Detection Limits < .026 mg/kg
HMP16 - Hazardous Metals (Paint) -
WHITE COATING ON PROPANE
TANKS
J14524 Barium Detectable Levels Present 22000 mg/Kg Chromium Detectable Levels Present 1100 mg/Kg Chromium, Hexavalent Detectable Levels Present 32 mg/Kg Lead Detectable Levels Present 16000 mg/Kg
J14525 Barium Detectable Levels Present 32000 mg/Kg Chromium Detectable Levels Present 1600 mg/Kg Chromium, Hexavalent Detectable Levels Present 24 mg/Kg
Lead Detectable Levels Present 25000 mg/Kg
Cadmium Below Detection Limits < 37 mg/Kg
J14542 Barium Detectable Levels Present 18000 mg/Kg Chromium Detectable Levels Present 2300 mg/Kg Chromium, Hexavalent Detectable Levels Present 68 mg/Kg Lead Detectable Levels Present 33000 mg/Kg
J14547 Aroclor 1254 Detectable Levels Present .082 mg/Kg Aroclor 1016 Below Detection Limits < .033 mg/Kg Aroclor 1221 Below Detection Limits < .045 mg/Kg Aroclor 1232 Below Detection Limits < .016 mg/Kg Aroclor 1242 Below Detection Limits < .015 mg/Kg Aroclor 1248 Below Detection Limits < .024 mg/Kg Aroclor 1260 Below Detection Limits < .029 mg/Kg http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP15&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP16&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp15.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP15&MatDesc=GRAY%20COATING%20ON%20LIGHT%20POLES&MatType=Hazardous%20Metals%20(Paint) http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp16.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP16&MatDesc=WHITE%20COATING%20ON%20PROPANE%20TANKS&MatType=Hazardous%20Metals%20(Paint)
HMP17 - Hazardous Metals (Paint) -
GRAY COATING ON ABOVE
GROUND COMMODITIES AND PIPE
SUPPORTS
J14536 Barium Detectable Levels Present 1000 mg/Kg Chromium Detectable Levels Present 1500 mg/Kg Chromium, Hexavalent Detectable Levels Present 20 mg/Kg Lead Detectable Levels Present 13000 mg/Kg Cadmium Below Detection Limits < 49 mg/Kg
J14537 Barium Detectable Levels Present 130 mg/Kg Chromium Detectable Levels Present 130 mg/Kg Chromium, Hexavalent Detectable Levels Present 1.9 mg/Kg
Lead Detectable Levels Present 1700 mg/Kg
Cadmium Below Detection Limits < 41 mg/Kg
J14538 Barium Detectable Levels Present 470 mg/Kg Chromium Detectable Levels Present 1100 mg/Kg Chromium, Hexavalent Detectable Levels Present 86 mg/Kg Lead Detectable Levels Present 13000 mg/Kg Cadmium Below Detection Limits < 48 mg/Kg
J14550 Aroclor 1254 Detectable Levels Present .038 mg/Kg Aroclor 1016 Below Detection Limits < .031 mg/Kg Aroclor 1221 Below Detection Limits < .042 mg/Kg Aroclor 1232 Below Detection Limits < .015 mg/Kg Aroclor 1242 Below Detection Limits < .014 mg/Kg Aroclor 1248 Below Detection Limits < .023 mg/Kg Aroclor 1260 Below Detection Limits < .027 mg/Kg
HMP18 - Hazardous Metals (Paint) -
GRAY COATING ON ELECTRICAL
EQUIPMENT RACK
J14534 Chromium, Hexavalent Detectable Levels Present 39 mg/Kg Barium Below Detection Limits < 100 mg/Kg Cadmium Below Detection Limits < 51 mg/Kg Chromium Below Detection Limits < 100 mg/Kg Lead Below Detection Limits < 100 mg/Kg
J14535 Barium Detectable Levels Present 150 mg/Kg Chromium Detectable Levels Present 490 mg/Kg Chromium, Hexavalent Detectable Levels Present 13 mg/Kg
Lead Detectable Levels Present 2800 mg/Kg
Cadmium Below Detection Limits < 52 mg/Kg
J14539 Barium Detectable Levels Present 320 mg/Kg Cadmium Detectable Levels Present 83 mg/Kg Chromium Detectable Levels Present 620 mg/Kg Chromium, Hexavalent Detectable Levels Present 84 mg/Kg Lead Detectable Levels Present 6400 mg/Kg
J14551 Aroclor 1254 Detectable Levels Present 0.17 mg/Kg Aroclor 1016 Below Detection Limits < .03 mg/Kg Aroclor 1221 Below Detection Limits < .041 mg/Kg Aroclor 1232 Below Detection Limits < .014 mg/Kg Aroclor 1242 Below Detection Limits < .014 mg/Kg Aroclor 1248 Below Detection Limits < .023 mg/Kg Aroclor 1260 Below Detection Limits < .026 mg/Kg http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP17&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP18&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp17.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP17&MatDesc=GRAY%20COATING%20ON%20ABOVE%20GROUND%20COMMODITIES%20AND%20PIPE%20SUPPORTS&MatType=Hazardous%20Metals%20(Paint) http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp18.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP18&MatDesc=GRAY%20COATING%20ON%20ELECTRICAL%20EQUIPMENT%20RACK&MatType=Hazardous%20Metals%20(Paint)
: SURVEY AREA 2
Facility: J7-0337 Facility Description: LAUNCH PAD 39B Date of Inspection: 6/16/2016 Inspectors: DS, ERF
Comments: Nelson Engineering project specific survey (RFQNE2016-101) Sample Area 2; South East pad perimeter road in general vicinity of the Foam Building
HMP19 - Hazardous Metals (Paint) -
GRAY/ BLACK COATING ON
HANDRAILS
J14571 Barium Detectable Levels Present 930 mg/Kg Chromium Detectable Levels Present 5300 mg/Kg Chromium, Hexavalent Detectable Levels Present 2400 mg/Kg Lead Detectable Levels Present 2800 mg/Kg Mercury Detectable Levels Present 15000 ug/Kg Cadmium Below Detection Limits < 51 mg/Kg
J14572 Aroclor 1248 Detectable Levels Present .83 mg/kg Aroclor 1260 Detectable Levels Present .9 mg/kg Aroclor 1016 Below Detection Limits < .032 mg/kg
Aroclor 1221 Below Detection Limits < .043 mg/kg
Aroclor 1232 Below Detection Limits < .015 mg/kg Aroclor 1242 Below Detection Limits < .014 mg/kg Aroclor 1254 Below Detection Limits < .029 mg/kg
J14575 Barium Detectable Levels Present 1400 mg/Kg Chromium Detectable Levels Present 4300 mg/Kg Chromium, Hexavalent Detectable Levels Present 1800 mg/Kg Lead Detectable Levels Present 3500 mg/Kg Mercury Detectable Levels Present 22000 ug/Kg
J14576 Barium Detectable Levels Present 1300 mg/Kg Chromium Detectable Levels Present 4700 mg/Kg Chromium, Hexavalent Detectable Levels Present 1800 mg/Kg Lead Detectable Levels Present 3400 mg/Kg Mercury Detectable Levels Present 2300 ug/Kg Cadmium Below Detection Limits < 43 mg/Kg
HMP20 - Hazardous Metals (Paint) -
GRAY/ BLACK VALVES
J14569 Barium Detectable Levels Present 6700 mg/Kg Cadmium Detectable Levels Present 75 mg/Kg Chromium Detectable Levels Present 1600 mg/Kg Chromium, Hexavalent Detectable Levels Present 620 mg/Kg Lead Detectable Levels Present 2500 mg/Kg Mercury Detectable Levels Present 21000 ug/Kg
J14570 Cadmium Detectable Levels Present 180 mg/Kg Chromium, Hexavalent Detectable Levels Present .042 mg/Kg Lead Detectable Levels Present 1100 mg/Kg
Mercury Detectable Levels Present 210 ug/Kg
Barium Below Detection Limits < 86 mg/Kg Chromium Below Detection Limits < 86 mg/Kg
J14577 Cadmium Detectable Levels Present 180 mg/Kg Chromium, Hexavalent Detectable Levels Present 340 mg/Kg Lead Detectable Levels Present 1100 mg/Kg Mercury Detectable Levels Present 3800 ug/Kg Barium Below Detection Limits < 79 mg/Kg Chromium Below Detection Limits < 79 mg/Kg
J14580 Aroclor 1254 Detectable Levels Present 1.1 mg/Kg http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP19&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP20&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp19.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP19&MatDesc=GRAY/%20BLACK%20COATING%20ON%20HANDRAILS&MatType=Hazardous%20Metals%20(Paint) http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp20.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP20&MatDesc=GRAY/%20BLACK%20VALVES&MatType=Hazardous%20Metals%20(Paint)
Aroclor 1260 Detectable Levels Present .93 mg/Kg Aroclor 1016 Below Detection Limits < .033 mg/kg Aroclor 1221 Below Detection Limits < .045 mg/kg Aroclor 1232 Below Detection Limits < .016 mg/kg Aroclor 1242 Below Detection Limits < .015 mg/kg Aroclor 1248 Below Detection Limits < .025 mg/kg
HMP21 - Hazardous Metals (Paint) -
GRAY/ BLACK METAL PIPING
J14573 Chromium Detectable Levels Present 780 mg/Kg Chromium, Hexavalent Detectable Levels Present 120 mg/Kg Lead Detectable Levels Present 56000 mg/Kg Mercury Detectable Levels Present 30000 ug/Kg
J14574 Aroclor 1248 Detectable Levels Present 8.1 mg/Kg Aroclor 1260 Detectable Levels Present 79 mg/Kg Aroclor 1016 Below Detection Limits < .032 mg/kg Aroclor 1221 Below Detection Limits < .043 mg/kg
Aroclor 1232 Below Detection Limits < .015 mg/kg Aroclor 1242 Below Detection Limits < .014 mg/kg Aroclor 1254 Below Detection Limits < .029 mg/kg
J14578 Chromium Detectable Levels Present 660 mg/Kg Chromium, Hexavalent Detectable Levels Present 53 mg/Kg Lead Detectable Levels Present 64000 mg/Kg Mercury Detectable Levels Present 31000 ug/Kg
J14579 Chromium Detectable Levels Present 310 mg/Kg Chromium, Hexavalent Detectable Levels Present 100 mg/Kg Lead Detectable Levels Present 42000 mg/Kg Mercury Detectable Levels Present 27000 ug/Kg Barium Below Detection Limits < 88 mg/Kg Cadmium Below Detection Limits < 44 mg/Kg
HMP22 - Hazardous Metals (Paint) -
WHITE PAINT ON CONCRETE CURB
J14565 Aroclor 1242 Detectable Levels Present 11 mg/Kg Aroclor 1254 Detectable Levels Present 3.7 mg/Kg Aroclor 1260 Detectable Levels Present 1.2 mg/Kg Aroclor 1016 Below Detection Limits < .031 mg/kg Aroclor 1221 Below Detection Limits < .043 mg/kg Aroclor 1232 Below Detection Limits < .015 mg/kg Aroclor 1248 Below Detection Limits < .023 mg/kg
J14566 Barium Detectable Levels Present 110 mg/Kg Cadmium Detectable Levels Present 310 mg/Kg Lead Detectable Levels Present 400 mg/Kg
Mercury Detectable Levels Present 3300 ug/Kg Chromium Below Detection Limits < 100 mg/Kg Chromium, Hexavalent Below Detection Limits < .035 mg/Kg
J14567 Chromium, Hexavalent Detectable Levels Present .11 mg/Kg Lead Detectable Levels Present 270 mg/Kg Mercury Detectable Levels Present 3100 ug/Kg Barium Below Detection Limits < 84 mg/Kg Cadmium Below Detection Limits < 42 mg/Kg Chromium Below Detection Limits < 84 mg/Kg
J14568 Lead Detectable Levels Present 160 mg/Kg Mercury Detectable Levels Present 4500 ug/Kg Barium Below Detection Limits < 87 mg/Kg Cadmium Below Detection Limits < 43 mg/Kg Chromium Below Detection Limits < 87 mg/Kg Chromium, Hexavalent Below Detection Limits < .035 mg/Kg http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP21&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP22&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp21.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP21&MatDesc=GRAY/%20BLACK%20METAL%20PIPING&MatType=Hazardous%20Metals%20(Paint) http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp22.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP22&MatDesc=WHITE%20PAINT%20ON%20CONCRETE%20CURB&MatType=Hazardous%20Metals%20(Paint)
SURVEY AREA 3
Facility: J7-0337
Facility Description: LAUNCH PAD 39B Date of Inspection: 6/21/2016 Inspectors: DS, ERF
Comments: Nelson Engineering project specific survey (RFQNE2016-101) Sample Area 3; East pad perimeter road in general vicinity of Camera Pad B-1
HMP23 - Hazardous Metals (Paint) -
WHITE COATING ON COMMUNIC
ATION BOXES
J14519 Aroclor 1016 Below Detection Limits < 0.033 mg/kg Aroclor 1221 Below Detection Limits < 0.045 mg/kg Aroclor 1232 Below Detection Limits < 0.016 mg/kg Aroclor 1242 Below Detection Limits < 0.015 mg/kg Aroclor 1248 Below Detection Limits < 0.024 mg/kg Aroclor 1254 Below Detection Limits < 0.030 mg/kg Aroclor 1260 Below Detection Limits < 0.029 mg/kg
J14602 Barium Detectable Levels Present 61000 mg/Kg Chromium, Hexavalent Detectable Levels Present 0.32 mg/Kg
Cadmium Below Detection Limits < 52 mg/Kg
Chromium Below Detection Limits < 100 mg/Kg
J14603 Barium Detectable Levels Present 43,000 mg/Kg Chromium, Hexavalent Detectable Levels Present 0.27 mg/Kg Cadmium Below Detection Limits < 48 mg/Kg Chromium Below Detection Limits < 96 mg/Kg Lead Below Detection Limits < 96 mg/Kg
J14604 Barium Detectable Levels Present 47,000 mg/Kg Chromium, Hexavalent Detectable Levels Present 0.15 mg/Kg Cadmium Below Detection Limits < 43 mg/Kg Chromium Below Detection Limits < 86 mg/Kg Lead Below Detection Limits < 86 mg/Kg
HMP24 - Hazardous Metals (Paint) -
GRAY COATING ON ELECTRICAL
EQUIPMENT
J14520 Aroclor 1016 Below Detection Limits < .0032 mg/kg Aroclor 1221 Below Detection Limits < 0.044 mg/kg Aroclor 1232 Below Detection Limits < 0.015 mg/kg Aroclor 1242 Below Detection Limits < 0.015 mg/kg Aroclor 1248 Below Detection Limits < 0.024 mg/kg Aroclor 1254 Below Detection Limits < 0.029 mg/kg Aroclor 1260 Below Detection Limits < 0.028 mg/kg
J14599 Barium Detectable Levels Present 1,500 mg/Kg Cadmium Detectable Levels Present 60 mg/Kg
Chromium Detectable Levels Present 880 mg/Kg
Chromium, Hexavalent Detectable Levels Present 56 mg/Kg Lead Detectable Levels Present 7,400 mg/Kg
J14600 Barium Detectable Levels Present 2,500 mg/Kg Chromium Detectable Levels Present 1,700 mg/Kg Chromium, Hexavalent Detectable Levels Present 59 mg/Kg Lead Detectable Levels Present 17,000 mg/Kg http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP23&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP24&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp23.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP23&MatDesc=WHITE%20COATING%20ON%20COMMUNIC%20ATION%20BOXES&MatType=Hazardous%20Metals%20(Paint) http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp24.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP24&MatDesc=GRAY%20COATING%20ON%20ELECTRICAL%20EQUIPMENT&MatType=Hazardous%20Metals%20(Paint)
J14601 Barium Detectable Levels Present 3,800 mg/Kg Chromium Detectable Levels Present 2,000 mg/Kg Chromium, Hexavalent Detectable Levels Present 360 mg/Kg Lead Detectable Levels Present 19,000 mg/Kg
HMP25 - Hazardous Metals (Paint) -
WHITE WITH GOLD BACKING
COATING ON LOW CAMERA
COMMUNICATION BOXES
J14588 Barium Detectable Levels Present 19,000 mg/Kg Chromium Detectable Levels Present 1,800 mg/Kg Chromium, Hexavalent Detectable Levels Present 0.11 mg/Kg Cadmium Below Detection Limits < 34 mg/Kg Lead Below Detection Limits < 69 mg/Kg
J14589 Barium Detectable Levels Present 14,000 mg/Kg Chromium Detectable Levels Present 780 mg/Kg Chromium, Hexavalent Detectable Levels Present 0.067 mg/Kg
Cadmium Below Detection Limits < 36 mg/Kg
Lead Below Detection Limits < 73 mg/Kg
J14590 Aroclor 1254 Detectable Levels Present 0.049 mg/Kg Aroclor 1016 Below Detection Limits < 0.031 mg/kg Aroclor 1221 Below Detection Limits < 0.042 mg/kg Aroclor 1232 Below Detection Limits < 0.015 mg/kg Aroclor 1242 Below Detection Limits < 0.014 mg/kg Aroclor 1248 Below Detection Limits < 0.023 mg/kg Aroclor 1260 Below Detection Limits < 0.027 mg/kg
J14591 Barium Detectable Levels Present 28,000 mg/Kg Chromium Detectable Levels Present 570 mg/Kg Chromium, Hexavalent Detectable Levels Present 0.072 mg/Kg Cadmium Below Detection Limits < 50 mg/Kg Lead Below Detection Limits < 99 mg/Kg
HMP26 - Hazardous Metals (Paint) -
WHITE COATING ON CAMERA
STANDS
J14595 Barium Detectable Levels Present 230 mg/Kg Chromium Detectable Levels Present 180 mg/Kg Chromium, Hexavalent Detectable Levels Present 0.72 mg/Kg Lead Detectable Levels Present 100 mg/Kg
J14596 Aroclor 1260 Detectable Levels Present 0.12 mg/Kg Aroclor 1016 Below Detection Limits < 0.033 mg/kg Aroclor 1221 Below Detection Limits < 0.045 mg/kg
Aroclor 1232 Below Detection Limits < 0.016 mg/kg
Aroclor 1242 Below Detection Limits < 0.015 mg/kg Aroclor 1248 Below Detection Limits < 0.025 mg/kg Aroclor 1254 Below Detection Limits < 0.030 mg/kg
J14597 Barium Detectable Levels Present 370 mg/Kg Chromium Detectable Levels Present 130 mg/Kg Chromium, Hexavalent Detectable Levels Present 0.70 mg/Kg Cadmium Below Detection Limits < 50 mg/Kg
J14598 Barium Detectable Levels Present 140 mg/Kg Chromium Detectable Levels Present 110 mg/Kg Chromium, Hexavalent Detectable Levels Present 2.2 mg/Kg Cadmium Below Detection Limits < 52 mg/Kg Lead Below Detection Limits < 100 mg/Kg Mercury Below Detection Limits < 60 ug/Kg http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP25&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP26&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp25.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP25&MatDesc=WHITE%20WITH%20GOLD%20BACKING%20COATING%20ON%20LOW%20CAMERA%20COMMUNICATION%20BOXES&MatType=Hazardous%20Metals%20(Paint) http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp26.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP26&MatDesc=WHITE%20COATING%20ON%20CAMERA%20STANDS&MatType=Hazardous%20Metals%20(Paint)
HMP27 - Hazardous Metals (Paint) -
WHITE COATING ON CAMERA
ENCLOSURE
J14587 Aroclor 1248 Detectable Levels Present 0.90 mg/Kg Aroclor 1254 Detectable Levels Present 1.1 mg/Kg Aroclor 1016 Below Detection Limits < 0.034 mg/kg Aroclor 1221 Below Detection Limits < 0.046 mg/kg Aroclor 1232 Below Detection Limits < 0.016 mg/kg Aroclor 1242 Below Detection Limits < 0.015 mg/kg Aroclor 1260 Below Detection Limits < 0.030 mg/kg
J14605 Barium Detectable Levels Present 26,000 mg/Kg Chromium Detectable Levels Present 1,600 mg/Kg
Chromium, Hexavalent Detectable Levels Present 8.2 mg/Kg
Cadmium Below Detection Limits < 51 mg/Kg
J14606 Barium Detectable Levels Present 27,000 mg/Kg Chromium Detectable Levels Present 1,600 mg/Kg Chromium, Hexavalent Detectable Levels Present 14 mg/Kg Cadmium Below Detection Limits < 52 mg/Kg
J14607 Barium Detectable Levels Present 26,000 mg/Kg Chromium Detectable Levels Present 1,500 mg/Kg Chromium, Hexavalent Detectable Levels Present 28 mg/Kg Cadmium Below Detection Limits < 53 mg/Kg http://amis.ksc.nasa.gov/matstatother.asp?HomogMatID=HMP27&facility=J7-0337&desc=LAUNCH%20PAD%2039B http://amis.ksc.nasa.gov/photo.asp?RelPath=/ksc/j7-0337/hmp27.jpg&FacCode=J7-0337&FacDesc=LAUNCH%20PAD%2039B&MatID=HMP27&MatDesc=WHITE%20COATING%20ON%20CAMERA%20ENCLOSURE&MatType=Hazardous%20Metals%20(Paint)
File details come from the government source that posted it.